CONTAINMENT PRODUCTS AND SERVICES - Data Centre Solutions€¦ · Hot/cold aisle containment. As a...
Transcript of CONTAINMENT PRODUCTS AND SERVICES - Data Centre Solutions€¦ · Hot/cold aisle containment. As a...
Whether you are building a new data centre or providing for the ever increasing power and cooling demands in a current facility,your project will require a mix of specific talents and expertise including: engineering, installation skills and project management.
Since 1982, Dataracks has been a leader in providing data centre solutions to some of the biggest names in the industry. We understand the special requirements of mission critical facilities and will create the most cost effective solution that meets the demanding requirements of your business. Additionally, our support services will help you make the most of your equipment by optimising performance and longevity.
Hot/cold aisle containmentAs a pioneer in the development and application of hot/cold aisle containment, Dataracks has unrivalled expertise in this area. We have developed solutions – both large scale and on a more modest size - for a wide range of customers.
Hot/cold aisle containment is a highly effective form of airflow management that results in the optimisation of cold air usage.
It improves the flow of cooled air through the data racking and aisles. It can be retrofitted in a live environment and maintains consistent optimum cool working temperatures. Effective airflow management gives you:
• Elimination of hot & cold air mixing• Control of humidity and static• Significant reduction in energy usage.• Control of inlet temperature• Eliminates hot spots
Cold aisle containment (CAC) works by creating a cold airplenum chamber within a cold aisle and preventing the mixing of hot and cold air flows.
Hot aisle containment (HAC) ensures the controlled flow of hotair back to the CRAC units. Dataracks offer two versions of HAC -ceiling plenum or rack chimneys
The optimum choice of CAC / HAC for any particular installation will depend on factors such as:
• Floor construction / air flow under voids• Ceiling construction and accessibility• Shape of data centre• Ducting
tel: +44 (0)1954 252800 email: [email protected] dataracks.com
CONTAINMENT PRODUCTS AND SERVICES
WHEN IT COMES TO
CONTAIN ING HOT & COLD,
WE ’RE THE EXPERTS!
Dataracks, Stagwood House, Beach Road, Cottenham, Cambridgeshire CB24 8FP
Whether you are building a new data centre
or providing for the ever increasing power
and cooling demands in a current facility,
your project will require a mix of specific
talents and expertise including: engineering,
installation skills and project management.
Since 1982, Dataracks has been a leader in providing data centre
solutions to some of the biggest names in the industry. We
understand the special requirements of mission critical facilities and
will create the most cost effective solution that meets the demanding
requirements of your business. Additionally, our support services
will help you make the most of your equipment by optimising
performance and longevity.
Hot/cold aisle containment
As a pioneer in the development and application of hot/cold aisle
containment, Dataracks has unrivalled expertise in this area. We
have developed solutions – both large scale and on a more modest
size - for a wide range of customers.
Hot/cold aisle containment is a highly effective form of airflow
management that results in the optimisation of cold air usage.
It improves the flow of cooled air through the data racking and aisles.
It can be retrofitted in a live environment and maintains consistent
optimum cool working temperatures.
Effective airflow management gives you:
n Elimination of hot & cold air mixing
n Control of humidity and static
n Significant reduction in energy usage.
n Control of inlet temperature
n Eliminates hot spots
Cold aisle containment (CAC) works by creating a cold air
plenum chamber within a cold aisle and preventing the mixing of hot
and cold air flows.
Hot aisle containment (HAC) ensures the controlled flow of hot
air back to the CRAC units. Dataracks offer two versions of HAC -
ceiling plenum or rack chimneys
The optimum choice of CAC / HAC for any particular installation will
depend on factors such as:
n Floor construction / air flow under voids
n Ceiling construction and accessibility
n Shape of data centre
n Ducting
+44 (0)1954 252800
www.dataracks .co.uk
The Dataracks Service
We will Design, manufacture and Install an optimum solution for
each individual situation, but solutions typically include:
n Stopping bypass air through unused U-space, vertical gaps between frames and side panels and tile cut
n Closing the ends of cold aisles to prevent cold/hot air recirculation and redirect cold airflow through the servers
n Closing in the space above the aisle with panels to prevent air re-circulation & hotspots
n Evening out the cold air distribution & temperature
n Balancing airflow though vented floor tiles
n Control of inlet temperature
n Solutions to fit all fire suppression systems
Our engineers will also consider issues such as balancing of CRAC
units, best solutions to handle fire suppression systems, work area
evacuation, compliance with standards, noise levels, access to
overhead space, integral security options and the ability to expand
for future storage requirements.
Retrofit solutions
Datacentres come in a wide variety of shapes and sizes many with
multiple rack sizes, brands, row layouts, obstacles. With our in-house
CAD/ CAM designers, full UK manufacturing facilities and own
installation engineers we have can handle anything from the basic
solution to the most complex environment
Our products
We manufacture a wide range of products that will make your data
centre more efficient. We also design and manufacture bespoke
solutions that can accommodate a wide range of scenarios.
The Dataracks Survey
We offer a free survey to assess your requirements and provide advice
and proposals that will fully meet your aspirations. Using thermal
imaging cameras we can quickly ascertain the flow of air in the aisles
and can formulate and fabricate a solution that will increase efficiency.
The survey will be undertaken by one of our highly experienced
engineers who can offer you an in-depth expertise that has been
gained over many years in working on many installations for major
organisations.
Cold aisle room parts
Cold aisle containment
Light weight roof panels
Cabinet roof supporting brackets
Door air seal strip
CRAC unit
Hot aisle Hot aisleCold aisle (contained)
Self closing doors
Top and bottom door guide system
Cover plates
No aisle entry floor level obstruction
When it comes to containing hot & cold, we’re the experts!
Whether you are building a new data centre
or providing for the ever increasing power
and cooling demands in a current facility,
your project will require a mix of specific
talents and expertise including: engineering,
installation skills and project management.
Since 1982, Dataracks has been a leader in providing data centre
solutions to some of the biggest names in the industry. We
understand the special requirements of mission critical facilities and
will create the most cost effective solution that meets the demanding
requirements of your business. Additionally, our support services
will help you make the most of your equipment by optimising
performance and longevity.
Hot/cold aisle containment
As a pioneer in the development and application of hot/cold aisle
containment, Dataracks has unrivalled expertise in this area. We
have developed solutions – both large scale and on a more modest
size - for a wide range of customers.
Hot/cold aisle containment is a highly effective form of airflow
management that results in the optimisation of cold air usage.
It improves the flow of cooled air through the data racking and aisles.
It can be retrofitted in a live environment and maintains consistent
optimum cool working temperatures.
Effective airflow management gives you:
n Elimination of hot & cold air mixing
n Control of humidity and static
n Significant reduction in energy usage.
n Control of inlet temperature
n Eliminates hot spots
Cold aisle containment (CAC) works by creating a cold air
plenum chamber within a cold aisle and preventing the mixing of hot
and cold air flows.
Hot aisle containment (HAC) ensures the controlled flow of hot
air back to the CRAC units. Dataracks offer two versions of HAC -
ceiling plenum or rack chimneys
The optimum choice of CAC / HAC for any particular installation will
depend on factors such as:
n Floor construction / air flow under voids
n Ceiling construction and accessibility
n Shape of data centre
n Ducting
+44 (0)1954 252800
www.dataracks .co.uk
The Dataracks Service
We will Design, manufacture and Install an optimum solution for
each individual situation, but solutions typically include:
n Stopping bypass air through unused U-space, vertical gaps between frames and side panels and tile cut
n Closing the ends of cold aisles to prevent cold/hot air recirculation and redirect cold airflow through the servers
n Closing in the space above the aisle with panels to prevent air re-circulation & hotspots
n Evening out the cold air distribution & temperature
n Balancing airflow though vented floor tiles
n Control of inlet temperature
n Solutions to fit all fire suppression systems
Our engineers will also consider issues such as balancing of CRAC
units, best solutions to handle fire suppression systems, work area
evacuation, compliance with standards, noise levels, access to
overhead space, integral security options and the ability to expand
for future storage requirements.
Retrofit solutions
Datacentres come in a wide variety of shapes and sizes many with
multiple rack sizes, brands, row layouts, obstacles. With our in-house
CAD/ CAM designers, full UK manufacturing facilities and own
installation engineers we have can handle anything from the basic
solution to the most complex environment
Our products
We manufacture a wide range of products that will make your data
centre more efficient. We also design and manufacture bespoke
solutions that can accommodate a wide range of scenarios.
The Dataracks Survey
We offer a free survey to assess your requirements and provide advice
and proposals that will fully meet your aspirations. Using thermal
imaging cameras we can quickly ascertain the flow of air in the aisles
and can formulate and fabricate a solution that will increase efficiency.
The survey will be undertaken by one of our highly experienced
engineers who can offer you an in-depth expertise that has been
gained over many years in working on many installations for major
organisations.
Cold aisle room parts
Cold aisle containment
Light weight roof panels
Cabinet roof supporting brackets
Door air seal strip
CRAC unit
Hot aisle Hot aisleCold aisle (contained)
Self closing doors
Top and bottom door guide system
Cover plates
No aisle entry floor level obstruction
When it comes to containing hot & cold, we’re the experts!
Cold aisle room parts
Cold aisle containment
Whether you are building a new data centre
or providing for the ever increasing power
and cooling demands in a current facility,
your project will require a mix of specific
talents and expertise including: engineering,
installation skills and project management.
Since 1982, Dataracks has been a leader in providing data centre
solutions to some of the biggest names in the industry. We
understand the special requirements of mission critical facilities and
will create the most cost effective solution that meets the demanding
requirements of your business. Additionally, our support services
will help you make the most of your equipment by optimising
performance and longevity.
Hot/cold aisle containment
As a pioneer in the development and application of hot/cold aisle
containment, Dataracks has unrivalled expertise in this area. We
have developed solutions – both large scale and on a more modest
size - for a wide range of customers.
Hot/cold aisle containment is a highly effective form of airflow
management that results in the optimisation of cold air usage.
It improves the flow of cooled air through the data racking and aisles.
It can be retrofitted in a live environment and maintains consistent
optimum cool working temperatures.
Effective airflow management gives you:
n Elimination of hot & cold air mixing
n Control of humidity and static
n Significant reduction in energy usage.
n Control of inlet temperature
n Eliminates hot spots
Cold aisle containment (CAC) works by creating a cold air
plenum chamber within a cold aisle and preventing the mixing of hot
and cold air flows.
Hot aisle containment (HAC) ensures the controlled flow of hot
air back to the CRAC units. Dataracks offer two versions of HAC -
ceiling plenum or rack chimneys
The optimum choice of CAC / HAC for any particular installation will
depend on factors such as:
n Floor construction / air flow under voids
n Ceiling construction and accessibility
n Shape of data centre
n Ducting
+44 (0)1954 252800
www.dataracks .co.uk
The Dataracks Service
We will Design, manufacture and Install an optimum solution for
each individual situation, but solutions typically include:
n Stopping bypass air through unused U-space, vertical gaps between frames and side panels and tile cut
n Closing the ends of cold aisles to prevent cold/hot air recirculation and redirect cold airflow through the servers
n Closing in the space above the aisle with panels to prevent air re-circulation & hotspots
n Evening out the cold air distribution & temperature
n Balancing airflow though vented floor tiles
n Control of inlet temperature
n Solutions to fit all fire suppression systems
Our engineers will also consider issues such as balancing of CRAC
units, best solutions to handle fire suppression systems, work area
evacuation, compliance with standards, noise levels, access to
overhead space, integral security options and the ability to expand
for future storage requirements.
Retrofit solutions
Datacentres come in a wide variety of shapes and sizes many with
multiple rack sizes, brands, row layouts, obstacles. With our in-house
CAD/ CAM designers, full UK manufacturing facilities and own
installation engineers we have can handle anything from the basic
solution to the most complex environment
Our products
We manufacture a wide range of products that will make your data
centre more efficient. We also design and manufacture bespoke
solutions that can accommodate a wide range of scenarios.
The Dataracks Survey
We offer a free survey to assess your requirements and provide advice
and proposals that will fully meet your aspirations. Using thermal
imaging cameras we can quickly ascertain the flow of air in the aisles
and can formulate and fabricate a solution that will increase efficiency.
The survey will be undertaken by one of our highly experienced
engineers who can offer you an in-depth expertise that has been
gained over many years in working on many installations for major
organisations.
Cold aisle room parts
Cold aisle containment
Light weight roof panels
Cabinet roof supporting brackets
Door air seal strip
CRAC unit
Hot aisle Hot aisleCold aisle (contained)
Self closing doors
Top and bottom door guide system
Cover plates
No aisle entry floor level obstruction
When it comes to containing hot & cold, we’re the experts!
Whether you are building a new data centre
or providing for the ever increasing power
and cooling demands in a current facility,
your project will require a mix of specific
talents and expertise including: engineering,
installation skills and project management.
Since 1982, Dataracks has been a leader in providing data centre
solutions to some of the biggest names in the industry. We
understand the special requirements of mission critical facilities and
will create the most cost effective solution that meets the demanding
requirements of your business. Additionally, our support services
will help you make the most of your equipment by optimising
performance and longevity.
Hot/cold aisle containment
As a pioneer in the development and application of hot/cold aisle
containment, Dataracks has unrivalled expertise in this area. We
have developed solutions – both large scale and on a more modest
size - for a wide range of customers.
Hot/cold aisle containment is a highly effective form of airflow
management that results in the optimisation of cold air usage.
It improves the flow of cooled air through the data racking and aisles.
It can be retrofitted in a live environment and maintains consistent
optimum cool working temperatures.
Effective airflow management gives you:
n Elimination of hot & cold air mixing
n Control of humidity and static
n Significant reduction in energy usage.
n Control of inlet temperature
n Eliminates hot spots
Cold aisle containment (CAC) works by creating a cold air
plenum chamber within a cold aisle and preventing the mixing of hot
and cold air flows.
Hot aisle containment (HAC) ensures the controlled flow of hot
air back to the CRAC units. Dataracks offer two versions of HAC -
ceiling plenum or rack chimneys
The optimum choice of CAC / HAC for any particular installation will
depend on factors such as:
n Floor construction / air flow under voids
n Ceiling construction and accessibility
n Shape of data centre
n Ducting
+44 (0)1954 252800
www.dataracks .co.uk
The Dataracks Service
We will Design, manufacture and Install an optimum solution for
each individual situation, but solutions typically include:
n Stopping bypass air through unused U-space, vertical gaps between frames and side panels and tile cut
n Closing the ends of cold aisles to prevent cold/hot air recirculation and redirect cold airflow through the servers
n Closing in the space above the aisle with panels to prevent air re-circulation & hotspots
n Evening out the cold air distribution & temperature
n Balancing airflow though vented floor tiles
n Control of inlet temperature
n Solutions to fit all fire suppression systems
Our engineers will also consider issues such as balancing of CRAC
units, best solutions to handle fire suppression systems, work area
evacuation, compliance with standards, noise levels, access to
overhead space, integral security options and the ability to expand
for future storage requirements.
Retrofit solutions
Datacentres come in a wide variety of shapes and sizes many with
multiple rack sizes, brands, row layouts, obstacles. With our in-house
CAD/ CAM designers, full UK manufacturing facilities and own
installation engineers we have can handle anything from the basic
solution to the most complex environment
Our products
We manufacture a wide range of products that will make your data
centre more efficient. We also design and manufacture bespoke
solutions that can accommodate a wide range of scenarios.
The Dataracks Survey
We offer a free survey to assess your requirements and provide advice
and proposals that will fully meet your aspirations. Using thermal
imaging cameras we can quickly ascertain the flow of air in the aisles
and can formulate and fabricate a solution that will increase efficiency.
The survey will be undertaken by one of our highly experienced
engineers who can offer you an in-depth expertise that has been
gained over many years in working on many installations for major
organisations.
Cold aisle room parts
Cold aisle containment
Light weight roof panels
Cabinet roof supporting brackets
Door air seal strip
CRAC unit
Hot aisle Hot aisleCold aisle (contained)
Self closing doors
Top and bottom door guide system
Cover plates
No aisle entry floor level obstruction
When it comes to containing hot & cold, we’re the experts!
tel: +44 (0)1954 252800 email: [email protected] dataracks.com
All dataracks products
are designed and manufactured
in the UK
Dataracks, Stagwood House, Beach Road, Cottenham, Cambridgeshire CB24 8FP
THE DATARACKS SERVICE
We will Design, manufacture and Install an optimum solution for each individual situation, but solutions typically include:
Stopping bypass air through unused U-space, vertical gaps between frames and side panels and tile cut
Closing the ends of cold aisles to prevent cold/hot air recirculation and redirect cold airflow through the servers
Closing in the space above the aisle with panels to prevent air re-circulation & hotspots
Evening out the cold air distribution & temperature
Balancing airflow though vented floor tiles Control of inlet temperature Solutions to fit all fire suppression systems
Our engineers will also consider issues such as balancing of CRAC units, best solutions to handle fire suppression systems, work areaevacuation, compliance with standards, noise levels, access to overhead space, integral security options and the ability to expand for future storage requirements.
RETROFIT SOLUTIONS
Datacentres come in a wide variety of shapes and sizes many with multiple rack sizes, brands, row layouts, obstacles. With our in-house CAD/ CAM designers, full UK manufacturing facilities and owninstallation engineers we have can handle anything from the basic solution to the most complex environment
OUR PRODUCTS
We manufacture a wide range of products that will make your data centre more efficient. We also design and manufacture bespoke solutions that can accommodate a wide range of scenarios.
THE DATARACKS SURVEY
We offer a free survey to assess your requirements and provide advice and proposals that will fully meet your aspirations. Using thermal imaging cameras we can quickly ascertain the flow of air in the aisles and can formulate and fabricate a solution that will increase efficiency.
The survey will be undertaken by one of our highly experienced engineers who can offer you an in-depth expertise that has been gained over many years in working on many installations for majororganisations.
ALL DATARACKS PRODUCTS ARE DESIGNED AND MANUFACTURED IN THE UK
Containment Products and Services
Dataracks
Stagwood House,
Beach Road,
Cottenham,
Cambridgeshire, CB24 8FP, UK
Tel: +44 (0)1954 252800
Fax: +44 (0)1954 251461
Email: [email protected]
Web: www.dataracks.co.uk
When it comes to
containing hot & cold, we’re the experts!
DATA CENTRE SOLUTIONS
DESIGNED, MANUFACTURED
AND INSTALLED JUST FOR YOU