CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4...

6
Wyo. Proj. Sheet of Sheets 0216001 BRIDGE PROGRAM WYOMING DEPARTMENT OF TRANSPORTATION DESIGN DETAIL REVISIONS of QTY'S Design Section Drwg No. Sheet 1 2 ML1105B, RM 0.05 SEC 20, T17N, R60W REVIEW APPROVAL HHH NNN Q R Stuv P-0005 0216001_1pl1.dgn 4 . 01 - E x a m p l e SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT LARAMIE COUNTY 0216001 STA 960+50 ALBIN ROAD GENERAL NOTES S ec ti on 4 . 01 - P r e li m i n a r y PRELIMINARY STRUCTURE NO. M-IJG-C Nov 2018 SPECIFICATIONS: WYDOT Standard Specifications for Road and Bridge CONCRETE AGGREGATE: Ensure all concrete mix designs employed in the project meet the following alkali-silica reactivity (ASR) screening. been performed within 12 months of the submittal date. Ensure the AASHTO T 303 (ASTM C 1260), and ASTM C 1567 tests have non-reactive and mitigation measures are not required. at 16 days from casting of 0.10 percent or less, the aggregate is considered be used in the concrete mix design. If the test results indicate an expansion of fine aggregate and coarse aggregate, in the same proportions that will Conduct the AASHTO T 303 (ASTM C 1260) test using a combined sample the cementitious material that is to be used in the mix design. same proportions that will be used in the concrete mix design and use use a combined sample of fine aggregate and coarse aggregate, in the casting of 0.10 percent or less. When conducting the ASTM C 1567 test, and ensuring the test results indicate an expansion at 16 days from Demonstrate adequate mitigation by conducting the ASTM C 1567 test Materials Testing Manual, silica fume, and/or lithium nitrate additive. a class F fly ash as approved for ASR mitigation in accordance with the than 0.10 percent, mitigate the aggregate reactivity through the use of If the test results indicate an expansion at 16 days from casting of greater mix design request. production. Submit test results to the Materials Program along with each results to the engineer a minimum of 14 calendar days before concrete Submit qualifying AASHTO T 303 (ASTM C 1260) and ASTM C 1567 test DIMENSIONS: Longitudinal dimensions are along flow line. Slopes are vertical : horizontal. BAR MARKS Straight Bars Bent Bars Size Length Designation 508-3 4A2 Size REMOVAL OF STRUCTURES AND OBSTRUCTIONS: Remove the existing EYEBOLTS: Use galvanized bar conforming to ASTM A 709 (Grade 36). Work Concrete. necessary for the eyebolts is incidental to the contract pay item Class A WEEP HOLE ASSEMBLIES: Work necessary for the weep hole assemblies is incidental to the contract pay item Class A Concrete. PREFORMED EXPANSION JOINT FILLER: Work necessary for the preformed expansion joint filler is incidental to the contract pay item Class A Concrete. 72"ø x 60'-0"± corrugated metal pipe. CULVERT EXCAVATION: The estimated quantity of culvert excavation, including Obstructions. and is incidental to the contract pay item Removal of Structures and removal of the existing pipe and excavation for the new culvert, is 90 CY OPTIONAL CONSTRUCTION JOINT BASE: If the optional construction joint in contract pay item Class A Concrete. the bottom slab is used, work necessary for the base is incidental to the Construction, 2010 Edition. REFERENCES Supplementary Specifications: SS-100K Adjustment for Structural Steel DESIGN DATA Standard Plans: 206-1A 511-1A Culvert and Trench Excavation Wire Enclosed Riprap and Gabions ESTIMATED QUANTITIES ITEM NO. ITEM UNIT QUANTITY TOTAL ESTIMATE 202.03100 212.03900 CY LS LUMP SUM 511.01000 CY 513.00005 CLASS A CONCRETE LS LUMP SUM 514.00015 LS LUMP SUM REMOVAL OF STRUCTURES AND OBSTRUCTIONS PERVIOUS BACKFILL MATERIAL GABIONS REINFORCING STEEL X EA X X X CY X LB are out to out. Ensure bars marked with an asterisk (*) are coated. bars bent for Dimensions noted. unless 2" is steel reinforcing of face (Grade 60) for all bars, including ties and stirrups. Concrete cover to 615 A ASTM to conforms steel reinforcing Ensure STEEL: REINFORCING LOADING: REINFORCED CONCRETE: Load and Resistance Factor Design - f ' ADT: 185 (Year 2008) Dead Load: Live Load: 72 pcf 120 pcf Lateral earth pressure: Vertical earth pressure: Design fill: 0.6 ft± Lateral live load surcharge: 2 ft earth or 72 psf HL93 APPROACH ROADWAY WIDTH: 36'-0" 8th Edition. SPECIFICATIONS: AASHTO LRFD Bridge Design Specifications, f y c = 60,000 psi (Grade 60) = 4000 psi Reinforcing Steel Class A Concrete

Transcript of CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4...

Page 1: CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4 STA 960+50 Albin Road 0216001 La SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT

Wyo. Proj.

Sheet of Sheets

0216001

BRIDGE PROGRAM

WYOMING DEPARTMENT OF TRANSPORTATION

DESIGN

DETAIL

REVISIONS

ofQTY'S

Design Section

Drwg No. Sheet 1 2

ML1105B, RM 0.05

SEC 20, T17N, R60W

REVIEW

APPROVAL

HHH NNNQ R Stuv

P-0005

0216001_1pl1.dgn

4.0

1 - E

xa

mple

SINGLE BARREL 8'-0" X 8'-0"

CONCRETE BOX CULVERT

LARAMIE COUNTY0216001

STA 960+50

ALBIN ROAD

GENERAL NOTES

Sectio

n 4.0

1 - Prelim

inary

PRELIMINARY

STRUCTURE NO. M-IJG-C

Nov 2

018

SPECIFICATIONS: WYDOT Standard Specifications for Road and Bridge

CONCRETE AGGREGATE: Ensure all concrete mix designs employed in the

project meet the following alkali-silica reactivity (ASR) screening.

been performed within 12 months of the submittal date.

Ensure the AASHTO T 303 (ASTM C 1260), and ASTM C 1567 tests have

non-reactive and mitigation measures are not required.

at 16 days from casting of 0.10 percent or less, the aggregate is considered

be used in the concrete mix design. If the test results indicate an expansion

of fine aggregate and coarse aggregate, in the same proportions that will

Conduct the AASHTO T 303 (ASTM C 1260) test using a combined sample

the cementitious material that is to be used in the mix design.

same proportions that will be used in the concrete mix design and use

use a combined sample of fine aggregate and coarse aggregate, in the

casting of 0.10 percent or less. When conducting the ASTM C 1567 test,

and ensuring the test results indicate an expansion at 16 days from

Demonstrate adequate mitigation by conducting the ASTM C 1567 test

Materials Testing Manual, silica fume, and/or lithium nitrate additive.

a class F fly ash as approved for ASR mitigation in accordance with the

than 0.10 percent, mitigate the aggregate reactivity through the use of

If the test results indicate an expansion at 16 days from casting of greater

mix design request.

production. Submit test results to the Materials Program along with each

results to the engineer a minimum of 14 calendar days before concrete

Submit qualifying AASHTO T 303 (ASTM C 1260) and ASTM C 1567 test

DIMENSIONS: Longitudinal dimensions are along flow line. Slopes are

vertical : horizontal. BAR MARKS

Straight Bars Bent Bars

Size Length Designation

508-3 4A2

Size

REMOVAL OF STRUCTURES AND OBSTRUCTIONS: Remove the existing

EYEBOLTS: Use galvanized bar conforming to ASTM A 709 (Grade 36). Work

Concrete.

necessary for the eyebolts is incidental to the contract pay item Class A

WEEP HOLE ASSEMBLIES: Work necessary for the weep hole assemblies is

incidental to the contract pay item Class A Concrete.

PREFORMED EXPANSION JOINT FILLER: Work necessary for the preformed

expansion joint filler is incidental to the contract pay item Class A Concrete.

72"ø x 60'-0"± corrugated metal pipe.

CULVERT EXCAVATION: The estimated quantity of culvert excavation, including

Obstructions.

and is incidental to the contract pay item Removal of Structures and

removal of the existing pipe and excavation for the new culvert, is 90 CY

OPTIONAL CONSTRUCTION JOINT BASE: If the optional construction joint in

contract pay item Class A Concrete.

the bottom slab is used, work necessary for the base is incidental to the

Construction, 2010 Edition.

REFERENCES

Supplementary Specifications:

SS-100K Adjustment for Structural Steel

DESIGN DATA

Standard Plans:

206-1A

511-1A

Culvert and Trench Excavation

Wire Enclosed Riprap and Gabions

ESTIMATED QUANTITIES

ITEM NO. ITEM UNITQUANTITY

TOTALESTIMATE

202.03100

212.03900 CY

LS LUMP SUM

511.01000 CY

513.00005 CLASS A CONCRETE LS LUMP SUM

514.00015 LS LUMP SUM

REMOVAL OF STRUCTURES AND OBSTRUCTIONS

PERVIOUS BACKFILL MATERIAL

GABIONS

REINFORCING STEEL

X EA

X

X

X CY

X LB

are out to out. Ensure bars marked with an asterisk (*) are coated.

barsbent for Dimensions noted. unless 2" is steel reinforcing of face

(Grade 60) for all bars, including ties and stirrups. Concrete cover to

615A ASTM to conforms steel reinforcing Ensure STEEL: REINFORCING

LOADING:

REINFORCED CONCRETE: Load and Resistance Factor Design -

f'

ADT: 185 (Year 2008)

Dead Load:

Live Load:

72 pcf

120 pcf

Lateral earth pressure:

Vertical earth pressure:

Design fill: 0.6 ft±

Lateral live load surcharge: 2 ft earth or 72 psf

HL93

APPROACH ROADWAY WIDTH: 36'-0"

8th Edition.

SPECIFICATIONS: AASHTO LRFD Bridge Design Specifications,

fy

c

= 60,000 psi (Grade 60)

= 4000 psi

Reinforcing Steel

Class A Concrete

Page 2: CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4 STA 960+50 Albin Road 0216001 La SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT

Wyo. Proj.

Sheet of Sheets

DESIGN

DETAIL

Design Section

ofSheetDrwg No.QTY'S

REVIEW

APPROVAL

REVISIONS

WYOMING DEPARTMENT OF TRANSPORTATION

BRIDGE PROGRAM

2

0216001

HHH NNNQ R Stuv

STA 960+50

Albin Road

0216001 La

SINGLE BARREL 8'-0" X 8'-0"

CONCRETE BOX CULVERT

N

90°

Ë Survey

Ë

Culv

ert

LOCATION PLAN

N 8

9°09'0

0" E

FLOW

2P-0005

0216001_1pl2.dgn

PRELIMINARY LAYOUT

4.0

1 - E

xa

mple

Sectio

n 4.0

1 - Prelim

inary

SECTION A-A

Elev 5280.35Flow Line

LONGITUDINAL SECTION

Ë Survey

10"± Borrow Special Excavation

TYPICAL ROADWAY SECTION

Nov 2

018

R/W Line (Typ)

Existing Highway

Sta 960+50.00

Ë Culvert

Pole (Typ)

Power

Overhead Power Line

High West Energy Co.

TO A

LBIN

TO PIN

E B

LU

FFS

960+50

961+00

41'-0" 41'-0"

82'-0" 16'-0"±

Gabions

8'-0"

8'-0"

A

A

Elev 5280.66Slope 0.50%

25'-0" Clear Zone 25'-0" Clear Zone

36'-0"

12'-0" 12'-0"6'-0" 6'-0"

4"± Hot Plant Mix

Shoulder ShoulderTraveled WayTraveled Way

Grade

Profile

6"± Crushed Base

Slope 2% Slope 2%

1:41:4

Page 3: CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4 STA 960+50 Albin Road 0216001 La SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT

REFERENCES

Supplementary Specifications:

SS-100K Adjustment for Structural Steel

Wyo. Proj.

Sheet of Sheets

0216001

B4

BRIDGE PROGRAM

WYOMING DEPARTMENT OF TRANSPORTATION

DESIGN

DETAIL

REVISIONS

ofQTY'S

Design Section

Drwg No. Sheet 1 4

ML1105B, RM 0.05

SEC 20, T17N, R60W

REVIEW

APPROVAL

HHH NNNQ R Stuv

0216001_1ts.dgn

B1

4.0

2 - E

xa

mple

Sectio

n 4.0

2 - G

eneral N

ote

s

SINGLE BARREL 8'-0" X 8'-0"

CONCRETE BOX CULVERT

LARAMIE COUNTY0216001

STA 960+50

ALBIN ROAD

GENERAL NOTES

SPECIFICATIONS: WYDOT Standard Specifications for Road and Bridge

CONCRETE AGGREGATE: Ensure all concrete mix designs employed in the

project meet the following alkali-silica reactivity (ASR) screening.

been performed within 12 months of the submittal date.

Ensure the AASHTO T 303 (ASTM C 1260), and ASTM C 1567 tests have

non-reactive and mitigation measures are not required.

at 16 days from casting of 0.10 percent or less, the aggregate is considered

be used in the concrete mix design. If the test results indicate an expansion

of fine aggregate and coarse aggregate, in the same proportions that will

Conduct the AASHTO T 303 (ASTM C 1260) test using a combined sample

the cementitious material that is to be used in the mix design.

same proportions that will be used in the concrete mix design and use

use a combined sample of fine aggregate and coarse aggregate, in the

casting of 0.10 percent or less. When conducting the ASTM C 1567 test,

and ensuring the test results indicate an expansion at 16 days from

Demonstrate adequate mitigation by conducting the ASTM C 1567 test

Materials Testing Manual, silica fume, and/or lithium nitrate additive.

a class F fly ash as approved for ASR mitigation in accordance with the

than 0.10 percent, mitigate the aggregate reactivity through the use of

If the test results indicate an expansion at 16 days from casting of greater

mix design request.

production. Submit test results to the Materials Program along with each

results to the engineer a minimum of 14 calendar days before concrete

Submit qualifying AASHTO T 303 (ASTM C 1260) and ASTM C 1567 test

DIMENSIONS: Longitudinal dimensions are along flow line. Slopes are

vertical : horizontal. BAR MARKS

Straight Bars Bent Bars

Size Length Designation

508-3 4A2

Size

REMOVAL OF STRUCTURES AND OBSTRUCTIONS: Remove the existing

EYEBOLTS: Use galvanized bar conforming to ASTM A 709 (Grade 36). Work

Concrete.

necessary for the eyebolts is incidental to the contract pay item Class A

WEEP HOLE ASSEMBLIES: Work necessary for the weep hole assemblies is

incidental to the contract pay item Class A Concrete.

PREFORMED EXPANSION JOINT FILLER: Work necessary for the preformed

expansion joint filler is incidental to the contract pay item Class A Concrete.

72"ø x 60'-0"± corrugated metal pipe.

CULVERT EXCAVATION: The estimated quantity of culvert excavation, including

Obstructions.

and is incidental to the contract pay item Removal of Structures and

removal of the existing pipe and excavation for the new culvert, is 90 CY

OPTIONAL CONSTRUCTION JOINT BASE: If the optional construction joint in

contract pay item Class A Concrete.

the bottom slab is used, work necessary for the base is incidental to the

ESTIMATED QUANTITIES

ITEM NO. ITEM UNITQUANTITY

TOTALESTIMATE

202.03100

212.03900 CY

LS LUMP SUM

511.01000 CY

513.00005 CLASS A CONCRETE LS LUMP SUM

514.00015 LS LUMP SUM

REMOVAL OF STRUCTURES AND OBSTRUCTIONS

PERVIOUS BACKFILL MATERIAL

GABIONS

REINFORCING STEEL

1 EA

12

30

106.2 CY

10,330 LB

DESIGN DATA

Standard Plans:

206-1A

511-1A

Culvert and Trench Excavation

Wire Enclosed Riprap and Gabions

0005

Construction, 2010 Edition.

STRUCTURE NO. M-IJG-C

Nov 2

018

LOADING:

REINFORCED CONCRETE: Load and Resistance Factor Design -

f'

ADT: 185 (Year 2008)

Dead Load:

Live Load:

72 pcf

120 pcf

Lateral earth pressure:

Vertical earth pressure:

Design fill: 0.6 ft±

Lateral live load surcharge: 2 ft earth or 72 psf

HL93

APPROACH ROADWAY WIDTH: 36'-0"

8th Edition.

SPECIFICATIONS: AASHTO LRFD Bridge Design Specifications,

are out to out. Ensure bars marked with an asterisk (*) are coated.

barsbent for Dimensions noted. unless 2" is steel reinforcing of face

(Grade 60) for all bars, including ties and stirrups. Concrete cover to

615A ASTM to conforms steel reinforcing Ensure STEEL: REINFORCING

fy

c

= 60,000 psi (Grade 60)

= 4000 psi

Reinforcing Steel

Class A Concrete

Page 4: CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4 STA 960+50 Albin Road 0216001 La SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT

Wyo. Proj.

Sheet of Sheets

DESIGN

DETAIL

Design Section

ofSheetDrwg No.QTY'S

REVIEW

APPROVAL

REVISIONS

WYOMING DEPARTMENT OF TRANSPORTATION

BRIDGE PROGRAM

2

0216001_1cu1.dgn

4.1

7 - E

xa

mple MMM

0216001

B4

Sectio

n 4.1

7 - C

ulv

erts

CULVERT DETAILS

NNN

HHH

HHH

NNN

NNN 0005

Q R Stuv

4

STA 960+50

Albin Road

0216001 La

SINGLE BARREL 8'-0" X 8'-0"

CONCRETE BOX CULVERT

Note:

BILL OF REINFORCEMENT

quantity of reinforcing steel.

Reinforcing steel shown as 4C2 is not included in the

B2

N

90°

Ë Survey

Ë

Culv

ert

LOCATION PLAN

N 8

9°09'0

0" E

FLOW

RIPRAP ELEVATION

Nov 2

018

(Weight)

LocationMark

Required

Number

4C2

409-0

425-3

440-10

442-3

5C3

5C4

505-2

509-0

440-10

442-9

508-7

4C1

540-10

542-7

10

6

24

10

10

164

84

196

164

16

16

164

18

10

10

(2361 LB)

Walls

Bottom Slab

& Footings

( 81 LB )

(4408 LB)

608-8

609-0

609-10

709-0

405-5

409-10

414-4

418-9

419-8

509-4

Set Bars

620-2

Bending Diagrams

2

80

4

80

4

4

4

4

4

4

16

8

(3561 LB)

& Parapets

Top Slab

(1166 LB)

Wingwalls

4C1 (Tie) 4C2 (Tie) 5C3 5C4

(4'-3") (6'-8") (3'-0") (3'-10")

Set Diagram

8"

1'-1"

11"

11"

2'-2"

4"

10"

1'-6"

2'-2"

10" 1'-8"

2'-2"

Set Bars (No. 5 Bars)

(Avg length=6'-6 ½")

Cut

Line 4'-5"

8'-8"

20

Bars

R/W Line (Typ)

Existing Highway

Sta 960+50.00

Ë Culvert

match flow line)

Gabions (Slope to

Pole (Typ)

Power

Overhead Power Line

High West Energy Co.

TO A

LBIN

TO PIN

E B

LU

FFS

960+50

961+00

41'-0" 41'-0"

82'-0" 16'-0"±

Gabionsunder entire limits of gabions)

Geotextile, Erosion Control (Place

8'-0"± 8'-0"±23'-0"±

1'-6"±

6"±

(Typ)

(Typ)

to Ë Culvert)

(Measured perpendicular

Page 5: CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4 STA 960+50 Albin Road 0216001 La SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT

Wyo. Proj.

Sheet of Sheets

DESIGN

DETAIL

Design Section

ofSheetDrwg No.QTY'S

REVIEW

APPROVAL

REVISIONS

WYOMING DEPARTMENT OF TRANSPORTATION

BRIDGE PROGRAM

4.1

7 - E

xa

mple MMM

0216001

B4

Sectio

n 4.1

7 - C

ulv

erts

CULVERT DETAILS

NNN

HHH

HHH

NNN

NNN 0005

Q R Stuv

4

STA 960+50

Albin Road

0216001 La

SINGLE BARREL 8'-0" X 8'-0"

CONCRETE BOX CULVERT

3

0216001_1cu2.dgn

B3

3)

2)

Note: 1)

4C1

609-10

PARAPET DETAIL

4C2

JOINT BASE DETAIL

OPTIONAL CONSTRUCTION

5C3

509-0

508-7

609-0 or 709-0

SECTION A-A

Opt Const Jt Base

540-10

440-10Opt Const Jt

3"

3"

Ë

Culv

ert (Sy

m)

409-0 (Typ &

Bott of Opt

Const Jt Base)

PLAN

440-10

Elev 5280.35Flow Line(Each wall)

1" x 3" Keyway

Const Jt w/

LONGITUDINAL SECTION

(Showing reinforcing steel placed in walls)

Nov 2

018

joint base.

reinforcing steel and optional construction

outlet is built first, reverse longitudinal

Either inlet or outlet may be built first. If

Place 508-7 bars with 5C3 bars.

Place short leg of 5C3 bars in bottom slab.

3" Cl

609-0

608-8

1'-0"

1'-6"

9"

9"

3" Cl

1" x 3" Keyway

Opt Const Jt w/

409-0 @

2 Eq Spa

1'-3" 1'-3"

2'-6"

9"

8"

508-7

5C3

Keyway (Typ)

w/ 1" x 3"

Const Jt

542-7 or 540-10 @ 9 Eq Spa

442-3 or 440-10 @ 9 Eq Spa

8'-0"

8'-0"

9'-4"

9'-5"

442-9 or 4

40-10 @ 1

2"

9"

8"

8"8"

6"

3" Cl

(Typ)

6"

Typ Row

Typ Row

442-3

542-7

4C1

A

A

82'-0"

41'-0" 41'-0"

1'-9"1'-9" 709-0 @ 12"=39'-0" 709-0 @ 12"=39'-0"

609-0 @ 12"=38'-0" 609-0 @ 12"=38'-0"

509-0 @ 6"=40'-6" 509-0 @ 6"=40'-6"

5C1 (Each wall) @ 12"=40'-0"5C1 (Each wall) @ 12"=40'-0"

4C2 @

Sho

win

gSho

win

g

top sla

bbott sla

b

12"=

4'-0"

4C1 @ 1

2"

=3'-0"

12"

8" (Typ)

3"

5"

3"

3"

3"

3"

6"

6"

6"

3"

3"

3"

3"

6"

1'-0"

(Typ)

1'-0"

(Typ)

1" x 3" Keyway

Const Jt w/

& Bott) (Typ)

609-10 (Top

(Typ)

609-0 (Bott)

608-8 (Top)

508-7 @ 12"=40'-0" (Each wall) 508-7 @ 12"=40'-0" (Each wall)

442-9

Elev 5280.66

Joint Base Detail

See Optional Construction

Slope 0.50%

(Typ)

8"

1'-0" (Typ)

6" 6"

3'-0"

2'-4"

See Parapet Detail (Typ)

6"6"

Typ Row - Each Wall

=7'-0" (

Each w

all)

Page 6: CONCRETE BOX CULVERT STA 960+50 Applications...CULVERT DETAILS NNN HHH HHH NNN NNN 0005 Q R Stuv 4 STA 960+50 Albin Road 0216001 La SINGLE BARREL 8'-0" X 8'-0" CONCRETE BOX CULVERT

Wyo. Proj.

Sheet of Sheets

DESIGN

DETAIL

Design Section

ofSheetDrwg No.QTY'S

REVIEW

APPROVAL

REVISIONS

WYOMING DEPARTMENT OF TRANSPORTATION

BRIDGE PROGRAM

4.1

7 - E

xa

mple MMM

0216001

B4

Sectio

n 4.1

7 - C

ulv

erts

CULVERT DETAILS

NNN

HHH

HHH

NNN

NNN 0005

Q R Stuv

4

STA 960+50

Albin Road

0216001 La

SINGLE BARREL 8'-0" X 8'-0"

CONCRETE BOX CULVERT

B4

4

0216001_1cu3.dgn

3)

2)

Note: 1)

Close joint

EYEBOLT DETAIL

Proj

6"

3"

1"ø

½"øBar

2 ½

"

1'-0"

1'-0"

Hardware Cloth

WEEP HOLE ASSEMBLY DETAIL

RF Wingwall

Fill Slope

2'-6"

behin

d win

gwall)

(Continuous

Backfill M

aterial

Pervio

us

Sack

Burlap 4 STD x 1'-0"

Weep Hole Pipe

(16 req'd for securing fence)

620-2

Set Bars

RF Wingwall

505-2

5C4

TYPICAL WINGWALL SECTION

504-5 (RF)

509-4 (RF)

Ë Weep Hole

Pipe (Typ)

TYPICAL WINGWALL ELEVATION

~

WINGWALL PLAN

(Inlet shown, outlet similar)

1'-0"

1'-0

"

Ë

Culv

ert (Sy

m)

Nov 2

018

burlap sack.

one cubic foot of coarse aggregate in a securely tied

end and firmly anchored to rear face of wingwall, and

(Minimum wire diameter 0.03") centered over pipe

or galvanized steel wire 4 mesh hardware cloth

through the wingwall, one 6" x 6" piece of aluminum

Each weep hole assembly consists of a pipe 4 STD

Place Set Bars and 509-4 bars with 5C4 bars.

Place short leg of 5C4 bars in footing.

5'-6"

3'-6"

4'-6"1'-0"

8"

419-8

2'-4"

3'-0"

425-3

3" Cl

1'-0"

405-5

409-10

414-4

418-9

Weep Hole Pipe

Keyway

w/ 2" x 4"

Const Jt

6" 6"

6"

1'-0"

1'-0"20'-0"

10'-0" 6'-0" 4'-0"

3'-0"

9'-0"

4'-6"

4'-6"

Set Bars @ 12"=19'-0" (RF)

7 S

pa @ 1

2"=

7'-0"

6"

620-2 (EF)

405-5 (RF)

409-10 (RF)

414-4 (RF)

418-9 (RF)

419-8 (RF)

508-8 (RF)

Expansion Joint Filler

½" Preformed

6"

Pipe (Typ)

Weep Hole

3"

3"

6"

1'-0 Á "

4 ¼

"

22'-0"

20'-0"

21'-0 Á "

15'-6 Á "

15'-6 Á "

18'-1 Á "

24'-6 Á "

3'-6"

2'-7"

1'-5"

3'-6

"

5'-6

"

505-2 @ 6"=

24'-0

"

5C4 @ 12"=

20'-0

"

425-3 @ 12"

=5'-0"

45°