Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months...
Transcript of Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months...
![Page 1: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/1.jpg)
Practice Advisor
Worldwide collection of before and after images and few settings from the renowned laser physicians
Clinical Casebook LightSheer® Treatments
LUMENIS.COM/AESTHETIC
![Page 2: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/2.jpg)
Images of treatments performed on Lumenis Diode Lasers Family, LightSheer®:
About LightSheer® Family:
Practice Advisor: LightSheer
® Family Treatments
LightSheer® DESIRETM
LightSheer® INFINITYTM
LightSheer® DUETTM
LightSheer® ET
The Gold Standard of Laser Hair Removal
FDA cleared for all skin types including treatments of pigmented and vascular lesions
Over 50 peer-reviewed articles
Best-in-class efficacy and comfort through customised treatments
All LightSheer systems are equipped with 805nm wavelength.
INFINITY has two diode wavelengths: 805nm and 1060nm
Hair Removal
• Shoulders
• Chin
• Legs
• Axillas
Pigmented Lesions Leg Vein Telangiectasia
• Back
• Arm
• Face
• Lower Abdomen
Unique technologies for pain reduction
Fastest treatments of all body areas with various spot-sizes, high peak power and adjustable pulse duration
Rapid proven return on investment
Images include:
![Page 3: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/3.jpg)
LightSheer Systems - Handpieces Overview
Handpiece DescriptionLightSheer
ETLightSheer
DUETLightSheer
DESIRELightSheer
DESIRE lightLightSheer INFINITY
ET (9x9 mm)
XC (12x12 mm)
HS (22x35 mm)
LR (9x27mm)
The ET has a Sapphire ChillTip of 9x9mm designed to treat small areas that require maximum precision and high fluence.
The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction,providing the safest, fastest and most comfortable treatment available in the market.
Variety of ChillTip applicators - utilize the ChillTip contact cooling technology and empowered by high fluence. Designed to treat small to medium size areas.
The XC has a Sapphire ChillTip of 12X12mm spot size, providing optimal solution for large and small areas requiring higher fluence levels.
![Page 4: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/4.jpg)
Courtesy of Girish Munavalli, M.D., M.H.S
Baseline 6 months follow up after 5 treatments
LightSheer DUET (HS Handpiece) - Lower Abdomen
![Page 5: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/5.jpg)
Courtesy of Girish Munavalli, M.D., M.H.S
Baseline 5 months follow up after 5 treatments
LightSheer DUET (HS Handpiece) - Axilla
![Page 6: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/6.jpg)
Courtesy of Suzanne Kilmer, M.D.
Skin type III, Brown hair, Fluence: 9-12 J/cm2, Pulse duration: 60-66ms, Vacuum: Medium
Baseline 6 months follow up after 3 treatments
LightSheer DUET (HS Handpiece) - Axilla
![Page 7: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/7.jpg)
Courtesy of Suzanne Kilmer, M.D.
Baseline 6 months follow up after 3 treatments
LightSheer DUET (HS Handpiece) - Axilla
Skin type IV, Brown hair , Fluence: 11 J/cm2, Pulse duration : 60-66ms, Vacuum: Medium
![Page 8: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/8.jpg)
Courtesy of Suzanne Kilmer, M.D.
Baseline 6 months follow up after 3 treatments
Skin type IV, Brown hair, Fluence: 10-11 J/cm2, Pulse duration: 54-100msec, Vacuum: Medium
LightSheer DUET (HS Handpiece) - Axilla
![Page 9: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/9.jpg)
Courtesy of Suzanne Kilmer, M.D.
Baseline 6 months follow up after 3 treatments
Fluence: 12 J/cm2, Pulse duration: 66ms, Vacuum: Medium
LightSheer DUET (HS Handpiece) - Axilla
![Page 10: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/10.jpg)
Courtesy of Mitchel Goldman, M.D.
Baseline After 2 treatments
LightSheer (HS Handpiece) - Back and Shoulders
Fluence: 10J/cm2, Pulse duration range: 30-70 ms (Custom mode), Vacuum: Medium, Number of Pulses: single pulsing
![Page 11: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/11.jpg)
Courtesy of Girish Munavalli, M.D.
Baseline After 5 treatments
LightSheer (ET Handpiece) - Lower Arm
Fluence: 34-38 J/cm2, Auto mode
![Page 12: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/12.jpg)
Courtesy of Valeria B. Campos, M.D., Christine C. Dierickx, M.D. and R. Rox Anderson, M.D.
36 months follow up after 5 treatmentsBaseline
LightSheer ET - Chin
Skin type III, Fluence: 40 J/cm2, Pulse duration: 20 ms
![Page 13: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/13.jpg)
Courtesy of Valeria B. Campos, M.D., Christine C. Dierickx, M.D. and R. Rox Anderson, M.D.
14 months follow up after 2 treatmentsBaseline
LightSheer ET - Lower Arm
Skin type II, Fluence: 40 J/cm2, Pulse duration: 20 ms
![Page 14: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/14.jpg)
Valeria B. Campos, M.D., Christine C. Dierickx, M.D. and R. Rox Anderson, M.D.
14 months follow up after 4 treatmentsBaseline
LightSheer ET - Chin
Skin type IV, Fluence: 2 treatments at 30 J/cm2, 2 treatments at 40 J/cm2
Pulse duration: 2 treatments at 15 ms, 2 treatments at 20 ms
![Page 15: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/15.jpg)
Courtesy of Nimish Patel, M.D.
Baseline 5 months follow up after 4 treatments
LightSheer ET - Back and Shoulders
Skin type V, Fluence: 23 J/cm2 Pulse Duration: treatments 1-3: 30 ms, treatment 4: Auto mode
![Page 16: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/16.jpg)
Courtesy of Nimish Patel, M.D.
Baseline 4 months follow up after 3 treatments
LightSheer ET - Axilla
Skin type: V, Fluence: 22-24 J/cm2, Pulse duration: 30 ms
![Page 17: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/17.jpg)
Courtesy of Nimish Patel, M.D.
Baseline 4 months follow up after 7 treatments
LightSheer ET - Face
Skin type: V, Fluence: 22-24 J/cm2, Pulse Duration: treatments 1-4: 30 ms, treatment 5-7: Auto
![Page 18: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/18.jpg)
Courtesy of Sushil Tahiliani, M.D.
Baseline 6 months follow up after 5 treatments
LightSheer INFINITY (1060nm HS Handpiece) - Upper Back and Shoulders
Skin type IV, Fluence: 6-7.5 J/cm2, Pulse Duration: 30 ms, Number of pulses: 3
![Page 19: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/19.jpg)
Baseline 6 months follow up after 5 treatments
LightSheer INFINITY (HS Handpiece) - Axilla
Courtesy of Sushil Tahiliani, M.D.
Skin type IV, Fluence: 12 J/cm2, Pulse Duration: 50-100 ms, Number of pulses: 2
![Page 20: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/20.jpg)
Baseline 6 months follow up after 5 treatments
LightSheer INFINITY (1060nm HS Handpiece) - Axilla
Courtesy of Sushil Tahiliani, M.D.
Skin type IV, Fluence: 12.5 J/cm2, Pulse Duration: 50-100 ms, Number of pulses: 1
![Page 21: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/21.jpg)
Courtesy of Sushil Tahiliani, M.D.
Baseline 6 months follow up after 5 treatments
LightSheer INFINITY (1060nm HS Handpiece) – Lower Arms
Skin type V, Fluence: 7.5-12.5 J/cm2, Pulse Duration: 30-50 ms
![Page 22: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/22.jpg)
LightSheer ET - Axilla
Skin type II, Fluence: 40J/cm2, Pulse Duration: 20 ms
Baseline 8 months follow up after 3 treatments
Courtesy of Robert M. Adrian, M.D., F.A.C.P.
![Page 23: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/23.jpg)
LightSheer ET - Neck
Skin type III, Fluence: 35J/cm2, Pulse Duration: 30 ms
Baseline 3 months follow up after 1 treatment
Courtesy of Robert M. Adrian, M.D., F.A.C.P.
![Page 24: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/24.jpg)
LightSheer ET - Face
Skin type III, Fluence: 35J/cm2, Pulse duration: 30 ms
Baseline 5 months follow up after 3 treatments
Courtesy of Robert M. Adrian, M.D., F.A.C.P.
![Page 25: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/25.jpg)
LightSheer ET - Bikini
Skin type II, Fluence: 40J/cm2, Pulse duration: 30 ms
Baseline 4 months follow up after 3 treatments
Courtesy of Robert M. Adrian, M.D., F.A.C.P.
![Page 26: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/26.jpg)
LightSheer DUET (ET Handpiece) - Face
Skin Type V, 1st session 22J/cm², 100ms, 2nd session 26J/cm², 100ms, 36 days post session #1, 3rd session 20J/cm², 30ms, 69 days post session #2, 4th session 22Jcm², 30ms, 63 days post session #3
Baseline 2 months follow up after 4 treatments
Courtesy of Rahul Pillai, M.D.
![Page 27: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/27.jpg)
LightSheer DUET (ET Handpiece) - Chin
Baseline 4 months follow up after 8 treatments
Courtesy of Rahul Pillai, M.D.
Skin Type IV, 1st session 22J/cm², 100ms, 2nd session 24J/cm², 100ms, 31 days post session #1, 3rd session 26J/cm², 100ms, 34 days post session #2, 4th session 18Jcm², 30ms, 49 days post session #3, 5th session 20J/cm², 30ms, 64 days post session#4, 6th session 22J/cm², 30ms, 62 days post session #5, 7th session 24J/cm², 30ms, 80 days post session #6, 8th session 24J/cm², 30ms, 120 days post session #7
![Page 28: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/28.jpg)
LightSheer DUET (HS Handpiece) - Axilla
Skin type IV, 1st session 5.5J/cm², 100ms, 2nd session 6J/cm², 100ms, 4 weeks post session #1,3rd session 5.5J/cm², 30ms, 8 weeks post session #2, 3 Months follow up post 3 treatments
Baseline 3 months follow up after 3 treatments
Courtesy of Soni Nanda, M.D.
![Page 29: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/29.jpg)
LightSheer DUET (ET Handpiece) - Lower Abdomen
Baseline After
Courtesy of Daniela Cangelosi, MD
![Page 30: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/30.jpg)
LightSheer INFINITY (1060 HS Handpiece) - Bikini
Courtesy of Suzanne Kilmer, M.D.
Baseline 6 months follow up after 7 treatments
Skin type III, Fluence: 7-12J/cm2, Pulse Duration: 50 ms, 1 pulse
![Page 31: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/31.jpg)
LightSheer INFINITY – Axilla
Courtesy of Suzanne Kilmer, M.D.
Baseline 6 months follow up after 7 treatments
Skin type III, Fluence: 6-12J/cm2, Pulse Duration: 50 ms, 1 pulse
![Page 32: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/32.jpg)
LightSheer INFINITY (1060nm HS Handpiece) - Lower Leg
Courtesy of E. Vic Ross, M.D.
Baseline 6 months follow up after 7 treatments
Skin type IV, Fluence: 10-12J/cm2, Pulse Duration: 40-50 ms, 1 pulse
![Page 33: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/33.jpg)
LightSheer INFINITY (HS Handpiece) - Axilla
Courtesy of E. Vic Ross, M.D.
Baseline 6 months follow up after 7 treatments
Skin type IV, Fluence: 9-12J/cm2, Pulse Duration: 40-50 ms, 1 pulse
![Page 34: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/34.jpg)
LightSheer ET (ET Handpiece) - Pigmented Lesions
Fluence: 40J/cm2, Pulse Duration: 30 ms
Baseline 2.5 months follow up after 1 treatment
Courtesy of Suzanne Kilmer M.D., Vera A. Chotzen, M.D. and Marla McClaren, M.D.
http://www.lumenis.com/Portals/0/Zoomedia/Use%20of%20the%20LightSheer%20Diode%20Laser%20System%20for%20the%20Treatment%20of%20Benign%20Pigmented%20Lesions.pdf
![Page 35: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/35.jpg)
LightSheer ET - Leg Veins
Courtesy of Valeria B. Campos, M.D., R. Rox Anderson M.D., and Christine C. Dierickx, M.D.
www.researchgate.net/publication/240635101_Use_of_an_800_nm_High-power_Diode_Laser_for_the_Treatment_of_Leg_Vein_Telangiectasia
Baseline 6 months follow up after 3 treatments
Fluence: 40 J/cm², Pulse Duration: 20 ms
![Page 36: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/36.jpg)
Baseline 24 months follow up after 3 treatments
Courtesy of Valeria B. Campos, M.D., R. Rox Anderson M.D., and Christine C. Dierickx, M.D.
Fluence: 40 J/cm², Pulse Duration: 20 ms
LightSheer ET (ET Handpiece) - Leg Veins
www.researchgate.net/publication/240635101_Use_of_an_800_nm_High-power_Diode_Laser_for_the_Treatment_of_Leg_Vein_Telangiectasia
![Page 37: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/37.jpg)
Lumenis - a Heritage in Innovation for Nearly Five Decades
First CO2 laser
supplied to Albert Einstein Hospital (NY, USA)
Introduced SuperPulseTM CO2 established as the standard in modern laser applications
Invented IPL, Intense Pulsed Light
Launched LightSheer® Technology for laser hair removal
Launched ActiveFXTM,
the world’s first fractional CO2
Launched DeepFXTM,
the world’s first micro-fractional CO2
Launched SCAAR FXTM, the
world’s first fractional CO2 to impact up to 4mm in depth for the most effective treatment of scars
Launched ResurFXTM,
the only true non-ablative fractional solution
Launched LightSheer® DUET, the first solution to include high speed diode hair removal with unique HIT technology
1973
1980
1993
1999
2005
2012
2013
2007
2008Over 50,000 Systems Installed in 6 Continents
![Page 38: Clinical Casebook LightSheer Treatments · LightSheer DUET (ET Handpiece) - Chin Baseline 4 months follow up after 8 treatments Courtesy of Rahul Pillai, M.D. Skin Type IV, 1st session](https://reader035.fdocuments.us/reader035/viewer/2022062506/5f08017e7e708231d41fdb47/html5/thumbnails/38.jpg)
For information on Lumenis’ products, please contact us at: [email protected] or at our direct offices in Germany, Italy or UK.
LUMENIS.COM/AESTHETIC
Lumenis GermanyHeinrich-Hertz-Strasse 363303 Dreieich Phone: +49 6103 83350E-mail: [email protected]
Lumenis ItalyVia Giulio Vincenzo Bona 8700156 RomaPhone: +39 06 90 75 230E-mail: [email protected]
Lumenis UK418 Centennial Park, ElstreeBorehamwood, Hertfordshire WD6 3TN Phone: +44 20 8736 4110E-mail: [email protected]
Engage with us on our social media channels: