10.1.1.1. XXX10.1.1. XXX
Section Guide Overview Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
10. EthErnEt nEtworks
sEction 10
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10.1.1.1. XXX10.1.1. XXX
Section Guide Overview Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
10. EthErnEt nEtworks
sEction 10
10-451
EthErnEt nEtworks
10. EthErnEt nEtworks 10-450section Guide overview 10-452
N-Tron Industrial Ethernet Network 10-452N-Tron Product Portfolio 10-453N-Tron OPC Server Software 10-454N-Tron EtherNet/IP with CIP Messaging 10-455Sixnet Industrial Ethernet Switches 10-456Sixnet Product Portfolio 10-457Unmanaged vs. Managed Ethernet Switches 10-458
10.1. Unmanaged Ethernet switches 10-46010.1.1. Light Duty 10-46010.1.2. Heavy Duty 10-46010.1.3. Monitored Heavy Duty 10-463
10.2. Managed Ethernet switches 10-46410.3. iP67 rated Ethernet switches 10-474
10.3.1. Unmanaged 10-47410.3.2. Managed 10-475
10.4. wireless radio Ethernet 10-47610.5. Power over Ethernet (PoE) 10-478
10.5.1. PoE Switches 10-47810.5.2. PoE Injectors 10-47810.5.3. PoE Splitters 10-479
10.6. cellular Modems & routers 10-48010.7. Media converters 10-48310.8. telephone Modem 10-483
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks
10
Section Guide OverviewN-Tron Industrial Ethernet Network
Primary Link
standby Link
control Link1 Gigabit
Fibre
100M Fibre
100M copper
security camera
security camera
nt24kDIN-Rail Modular
Managed Gigabit Switch
1003GX2DIN-Rail Unmanaged Gigabit Switch
7506GX2DIN-Rail Managed
Gigabit Switch(Jumbo-Packet Support)
7026tXRackmount Managed Gigabit Switch
GiG Devices
7012FX2DIN-Rail Managed Gigabit Switch
710FX2DIN-Rail Managed Switch
714FX6DIN-Rail
Managed Switch
708FX2DIN-Rail Managed Switch
100PoE4DIN-Rail PoE Injector
105tXDIN-Rail Unmanaged &
Unmonitored Switch
306tXDIN-Rail Unmanaged &
Monitored Switch
VsDhMiPLc
scADA
Gigabit Fibre optic cable (1000BaseFX)Fibre optic cable (100BaseFX)
Ethernet copper cable (10/100BasetX or 10/100/1000BasetX)
Power-over-Ethernet
10-453
Section Guide Overview
10
N-Tron Product Portfolio
Managed (Layer 2)
Monitored Unmanaged
Unmanaged
PoE
wireless
700 seriesPage 10-464
7000 seriesPage 10-466
nt24k seriesPage 10-470
7900 seriesPage 10-469
300 seriesPage 10-463
100 seriesPage 10-460
100 seriesPage 10-478
700 seriesPage 10-476
1000 seriesPage 10-461
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksSection Guide Overview
10
N-Tron OPC Server Software
The N-TRON N-View™ OLE for Process Control (OPC) Server Software will work with industry standard OPC Client software and most popular Human Machine Interface (HMI) packages, providing complete remote network traffic and status monitoring for N-TRON 300-N, 700, 7000, 7900 & NT24K Series Switches. The N-View OPC Server in combination with one or more of our industrial switches will add complete network visibility to an HMI Control and Monitoring application.
Ethernet switch Monitoring now Available on red Lion hMis
Red Lion Controls Crimson 3.0 configuration software now supports N-View server software from N-Tron. Therefore all N-Tron and Sixnet industrial Ethernet switches can be monitored from any locally-mounted Red Lion G3 operator interface.
This offers the unique benefit of using Red Lion operator interfaces as visible dashboards to monitor, display, log and alert on network status received from N-Tron and Sixnet industrial Ethernet switches. This level of compatibility between a HMI and Ethernet switch is unparalleled in the industry.
For applications with N-Tron switches, the integration of Crimson 3.0 and N-View allows plant managers and IT staff to efficiently monitor a number of different network parameters – including data collisions, received packets, dropped packets, alignment errors and more – from a single dashboard. For customers with Sixnet switches, monitoring is accomplished via Modbus. Advanced data logging features offer users the ability to collect and review network performance history. Email and SMS notification is also available to alert remote personal of network issues.
n-View switch Firmware
N-TRON Switches with the N-View firmware will auto cast a small Ethernet packet, periodically containing port-by-port status of the switch. This information includes 5 switch level data points and 41 data points per port. This data is captured by the N-View OPC Server Software and can be displayed by application software running in the same Windows environment with OPC Client capability.
Ease of Use
The N-TRON N-View Software includes the OPC Server and a configuration and monitoring software utility. This utility will automatically search the network for all N-View enabled switches using the unique IEEE MAC addresses to identify each switch. The switch MAC address can be selected and assigned an 80 character alias name. Meaningful alias names can also be added to all ports using the configuration software.The switch and port alias names can be saved and used by the N-View OPC Server as part of the switch variable names. The alias names can be used to help identify the location of the switch and the areas or equipment connected to the ports.
n-View oPc Data Variables
N-View OPC Server data variables can be accessed using N-View monitoring utility, or most popular HMI application software packages with OPC client capability. These variables can be divided into three general categories: Status variables indicate the operating condition of the switch or port; Traffic variables count the number of OCTETS (BYTES) of a specific type of Ethernet packet that have passed through a port since the start of the switch; and Error variables count the number of packet errors seen at each port since the start of the switch. HMI software packages can convert these variables to the data type required for display, alarming, and trending during the data scan update process.
10-455
Section Guide Overview
10
N-Tron EtherNet/IP with CIP Messaging
Ethernet/iP with ciP Messaging
N-TRON provides the convenience of CIP™ messaging for device management and monitoring with all of the benefits of N-TRON’s robust line of fully managed Hardened Industrial Switches. EtherNet/IP, ™ better known as the Common Industrial Protocol (CIP), was designed for use in process control and industrial automation applications. CIP was designed to provide consistent device access to eliminate the need for vendor specific software for configuration and monitoring of individual devices. With embedded support for CIP, N-TRON switches deliver information and configuration access directly to Programmable Logic Controllers (PLC’s) and HMI’s (Human Machine Interface) through standard CIP messaging. Switch status, trending and configuration are easily viewed from a PanelView Plus with screen resolutions of 640 x 480 and higher.
EtherNet/IP with CIP Messaging is a standard feature on the 700 Series (excluding wireless), 7010TX, 7018TX, 7018FX2, and 7506GX2. CIP tags, sample projects, and diagnostic faceplates for FactoryTalk® View ME/SE software (requires RSLogix 5000 version 17 and higher) are provided for quick setup and configuration in RSLogix 5000 environments.
Quickly view switch status using our provide face plates or access tagged data from your ladder locig program.
EB-PsE-24V-1ADIN-Rail PoE Injector
sLX-5Es-1DIN-Rail Unmanaged Switch
sL-5Es-1DIN-Rail
Unmanaged Switch
sn-6821-GECellular RouterrtU
security camerai/o Devices PLc hMi
Field cabinet control room
outdoor hMi PLc
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksSection Guide Overview
10
Sixnet Industrial Ethernet Switches
Enterprise intranet
EL326Rackmount Layer 3
Managed Gigabit Switch
EL326Rackmount Layer 3 Managed Gigabit Switch
wAn1
wAn2
EL228Rackmount Managed Gigabit Switch
sLX-8Ms-4DIN-Rail Managed Switch
EL228Rackmount Managed
Gigabit Switch
EL212FDIN-Rail Managed
Gigabit Switch
sLX-18MG-1DIN-Rail Managed
Gigabit Switch
sLX-18MG-1DIN-Rail Managed
Gigabit Switch
EL212FDIN-Rail Managed
Gigabit Switch
1 Gigabit Fibre
10 Gigabit Fibre
100M Fibre
100M copper
Gigabit Fibre optic cable (1000BaseFX)Fibre optic cable (100BaseFX)
Ethernet copper cable (10/100BasetX or 10/100/1000BasetX)control cable
Power-over-Ethernet
10-457
Section Guide Overview
10
Sixnet Product Portfolio
Managed (Layer 3)
Managed (Layer 2)
Unmanaged
PoE
Military rated
EL326 seriesPage 10-472
EL228 seriesPage 10-468
sLX seriesPage 10-465
sL seriesPage 10-460
sLX seriesPage 10-462
EB seriesPage 10-479
MiL seriesPage 10-473
Et seriesPage 10-473
EL212F seriesPage 10-467
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksSection Guide Overview
10
Unmanaged vs. Managed Ethernet Switches
Unmanaged switches
• Basic IEEE 802.3 MAC based switching functions.• No configurable parameters.• Some N-Tron unmanaged switches have the N-View option for remote real-time monitoring. Managed switches
• Assignable IP address• Web interface• IGMP snooping & N-View• Trunking (Port Aggregation), VLAN, QoS, RSTP, SNMP• Port Control & Port Mirroring
Layer 3 switches use the IP address to make switching decisions, as routers do, but are hardware optimized to transmit data just as fast as Layer 2 switches. Both routers and Layer 3 switches use a routing protocol and routing table to determine the best path. However, compared to routers, which are usually software-based, Layer 3 switches are faster and less expensive. This is due to their built-in switching hardware with optimized chips and full-wire speed IP frame forwarding performance suitable for interconnecting VLANs. Layer 3 switches use state-of-the-art routing technology to partition a large scale LAN into multiple subnets for improved network performance.
Trunking allows multiple physical ports to be linked together to function as one uplink to another Trunking capable switch configured in the same manner. The Trunking feature will increase the bandwidth between two switches and provides media redundancy.
The Quality of Service (QoS) feature provides prioritization of network traffic in order to provide better network service. The primary goal of QoS is to minimize the latency of prioritized Ethernet packets required for ring management, real-time and other interactive applications.
Virtual Local Area Network (VLAN) allows the segmentation of the network in order to create two or more separate or overlapping local area network domains. Industrial Ethernet switches can be setup for IEEE 802.1Q dynamic tagged VLAN or pre-determined port VLAN.
Unmanaged vs Managed
Managed switch Features
high-performance Layer 3 switching
Port trunking for reliable network redundancy
Qos increases Data Determinism
VLAn for network Planning
EL326 series
sLX-18MG sLX-18MG
sLX-18MG
Low PrioritY
Low PrioritY
hiGh PrioritYtoP PrioritY
hiGh PrioritY
toP PrioritY
collected Data
control Message
ManagementMessage
10-459
Section Guide Overview
10
Unmanaged vs. Managed Ethernet Switches
The Internet Group Management Protocol (IGMP) feature allows IGMP-capable switches to forward multicast traffic based on learned group addresses. IGMP Snooping is enabled by default. The ability to automatically detect bi-directional router ports and seamlessly form IGMP groups across multiple switches in some cases eliminates the need to configure the switch.
Simple Network Management Protocol (SNMP) is an “Internet-standard protocol for managing devices on IP networks. SNMP v3 primarily added security and remote configuration enhancements to the earlier versions. Authentication in SNMP Versions 1 and 2 amounts to nothing more than a password (community string) sent in clear text between a manager and agent in contrast to each SNMPv3 message that contains security parameters which are encoded as an octet string.
The Link Layer Discovery Protocol or LLDP (IEEE 802.1AB) is a data-link layer protocol that advertises device information, such as IP address, description, and system capabilities, to neighbouring devices over the network.
DHCP Option 82 refers to the “DHCP Relay Agent Information Option,” which allows a DHCP Relay Agent to insert detailed information, such as port information and MAC addresses of relay agents, to a request being transmitted to a DHCP server. DHCP servers can use this information to allocate IP addresses and other assignment settings that are mapped to its MAC address table.
Rapid spanning tree functionality permits managed switches to be configured in a ring or mesh topology. It also provides support for redundant path communications with rapid healing.
Port mirroring allows the traffic on one port to be duplicated and sent to a designated mirror port. Port mirroring can be used to monitor Ethernet traffic on the designated source port using the assigned mirror port.
IGMP Snooping for Filtering Multicast Traffic
snMP for Easy network Management
LLDP for Automated topology Discovery
intelligent DhcP option 82 iP Address Allocation
rstP (rapid spanning tree) for fast redundancy
Port Mirroring for enhanced network analysis
Group 2 Multicast streamGroup 1 Multicast stream
iGMP Group 1 iGMP Group 1iGMP Group 2iGMP Group 2
1. Event
1. i need an iP Address MAc: 00:90:E8:03:04:05
client
server
1.
4.
1.
Port 1
Port 3
Port 5
2.
3.
3.
2.
snMP Manager
DhcP server
2. snMP inform
2. i need an iP Address MAc: 00:90:E8:03:04:05 Device A, Port 7
3. snMP response
3. Your iP Address is 192.168.127.54. Your iP Address is 192.168.127.5
Got it!
!
internet
troubleshooting
Mirroring the Port 1 and 3 to 5
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksstock status:normally stocked /Not normally stocked
10
Discount code L7Discount code L7
10.1. Unmanaged Ethernet Switches10.1.1. Light Duty10.1.2. Heavy Duty
sL series - Light Duty
100 series - heavy Duty
order codes
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Unmanaged 5 5 - - - - - Plastic 10.6 x 2.5 x 8.3 sL-5Es-1
5 4 1 - - - - 10.6 x 2.5 x 8.3 sL-5Es-2XX
5 4 - 1 - - - 10.6 x 2.5 x 8.3 SL-5ES-3XX
6 4 2 - - - - 10.6 x 3.8 x 8.3 SL-6ES-4XX
6 4 - 2 - - - 10.6 x 3.8 x 8.3 SL-6ES-5XX
8 8 - - - - - 10.6 x 3.8 x 8.3 sL-8Es-1
9 8 1 - - - - 10.6 x 3.8 x 8.3 SL-9ES-2XX
9 8 - 1 - - - 10.6 x 3.8 x 8.3 SL-9ES-3XX
Ring 6 6 - - - - - 10.6 x 3.8 x 8.3 SL-6RS-1
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Unmanaged 4 4 - - - - - Metal 7.3 x 3.8 x 9.0 104tX
5 5 - - - - - 7.3 x 3.8 x 9.0 105tX
8 8 - - - - - 8.9 x 3.8 x 9.0 108tX
5 4 1 - - - - 8.9 x 3.8 x 9.0 105FX-XX
6 4 2 - - - - 8.9 x 3.8 x 9.0 106FX2-XX
5 5 - - - - - 10.2 x 2.6 x 9.2 105tX-sL
16 16 - - - - - 14.6 x 5.1 x 10.2 116tX
10 8 2 - - - - 10.8 x 6.1 x 11.5 110FX2-XX
10 8 - 2 - - - 10.8 x 6.1 x 11.5 110FX2-XX-YY
11 8 3 - - - - 10.8 x 6.1 x 11.5 111FX3-XX
11 8 - 3 - - - 10.8 x 6.1 x 11.5 111FX3-XX-YY
12 8 4 - - - - 10.8 x 7.9 x 11.5 112FX4-XX
12 8 - 4 - - - 10.8 x 7.9 x 11.5 112FX4-XX-YY
14 8 6 - - - - 10.8 x 7.9 x 11.5 114FX6XX
14 8 - 6 - - - 10.8 x 7.9 x 11.5 114FX6XX-YY
table code 100 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengths
table code sL seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre 20Km LengthsXX = ST or SC connectors
The SL line of unmanaged industrial Ethernet switches are ideal for light to moderate industrial applications. Available in 5, 6, 8 or 9 port options, our unmanaged SL switches offer protected circuitry and DIN-rail packaging to ensure rugged reliability and long-term service in industrial environments.
Product highlights
• Up to 9 fast Ethernet (10/100) ports • Up to 2 fibre optic ports for noise-immune links up to 120km • Low cost with high performance and value • Hardened design for light to medium industrial applications • Slim packaging fits on your DIN-rail • Dual power inputs keeps you running
The 100 Series provides compact network switches designed for high‐performance operation under harsh conditions. Each unmanaged model provides full‐wire speed communication, auto sensing and auto negotiation capabilities and an expanded feature set to tackle the demands of industrial data acquisition, control and Ethernet I/O applications. The series offers an array of port configurations, from all‐copper products to combination units with copper and fibre ports. Fibre optic units support communication over extended distances—up to 80km.
Product highlights
• Full IEEE 802.3 Compliance• Unmanaged Operation• Extended Environmental Specifications• -40ºC to 80ºC Operating Temperature• >2 Million Hours MTBF• Supports Full/Half Duplex Operation• Auto Sensing 10/100BaseTX, Duplex, MDIX
• Full Wire Speed Communication• Store-and-Forward Technology• Redundant Power Inputs • ESD Protection Diodes on all RJ-45 Ports• Surge Protection Diodes on Power Inputs• LED Link/Activity Status Indication• Hardened Metal DIN-Rail Enclosure
10-461
10.1. Unmanaged Ethernet Switches Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
1000 series - heavy Duty
order codes
Accessories
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Unmanaged 5 - - - 5 - - Metal 10.2 x 2.6 x 9.4 1005tX
3 - - - 1 1 1 10.2 x 2.6 x 9.4 1003GX2-B*
3 - - - 1 2 - 10.2 x 2.6 x 9.4 1003GX2-SX
3 - - - 1 - 2 10.2 x 2.6 x 9.4 1003GX2-LX-ZZ
* SFP Transceivers sold separately
table code 1000 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre ZZ = 10,40 or 80 for Single Mode fibre length
Description code
One 1000BaseSX Multimode SFP Gigabit Transceiver ntsFP-sX
One 1000BaseSX Singlemode SFP Gigabit Transceiver ntsFP-LX-ZZ
10.1.2. Heavy Duty
N‐Tron’s 1000 Series is ideal for industrial data acquisition, control and Ethernet I/O applications where a small footprint and gigabit speed is preferred. Ordering tip—the 1003GX2 comes pre‐configured with multimode or singlemode fibre SFP transceivers; 1003GX2‐SX with matching multimode full duplex fibre SFPs; the 1003GX2‐LX‐ZZ with two matching singlemode full duplex fibre SFPs (see full ordering table below). The 1003GX2 may also be ordered a la carte allowing you to mix‐and‐match various lengths of multimode and singlemode full duplex fibre. The 1000 Series is ABS‐approved for maritime environments.
Product highlights
• Compact Industrial Ethernet Gigabit Switches, ideal for Smaller Spaces• Plug‐and‐play Unmanaged Operation• RJ‐45 Ports Support Full/Half Duplex Operation• Auto Sensing Speed and Flow Control (RJ‐45)• Full IEEE 802.3, 802.3u, 802.3z and 802.3ab Compliance• ‐40°C to 85°C Operating Temperature• Fully Redundant Power Inputs (10‐30 VDC)• ESD Protection Diodes on RJ‐45 Ports and• Surge Protection Diodes on Power Inputs
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks10.1. Unmanaged Ethernet Switches Stock Status:
Normally stocked /Not normally stocked
10
Discount code L7
table code sLX seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre 20Km LengthsXX = ST or SC connectors
sLX series - heavy Duty
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Unmanaged 5 5 - - - - - Metal 10.2 x 2.5 x 7.6 SLX-5ES-1
5 4 1 - - - - 10.2 x 2.5 x 7.6 SLX-5ES-2XX
5 4 - 1 - - - 10.2 x 2.5 x 7.6 SLX-5ES-3XX
5 4 - 1 - - - 10.2 x 2.5 x 7.6 SLX-5ES-3XXL*
6 4 2 - - - - 10.2 x 3.8 x 7.6 sLX-6Es-4XX
6 4 - 2 - - - 10.2 x 3.8 x 7.6 SLX-6ES-5XX
6 4 2 - - - - 10.2 x 3.8 x 7.6 SLX-6ES-5XXL*
8 8 - - - - - 10.2 x 3.8 x 7.6 SLX-8ES-1
9 8 1 - - - - 10.2 x 3.8 x 7.6 SLX-9ES-2XX
9 8 - 1 - - - 10.2 x 3.8 x 7.6 SLX-9ES-3XX
9 8 - 1 - - - 10.2 x 3.8 x 7.6 SLX-9ES-3XXL*
8 5 3 - - - - 10.2 x 3.8 x 7.6 SLX-8ES-6XX
8 5 - 3 - - - 10.2 x 3.8 x 7.6 SLX-8ES-7XX
8 5 - 3 - - - 10.2 x 3.8 x 7.6 SLX-8ES-7XXL*
Ring 6 6 - - - - - 10.2 x 3.8 x 7.6 SLX-6RS-1
* Single Mode Fibre 60+Km Lengths
The SLX line of unmanaged industrial Ethernet switches are designed to meet performance requirements that extreme applications demand. Available in 5, 6, 8 or 9 port options, our unmanaged SLX switches offer protected circuitry and tough DIN-rail metal packaging to ensure rugged reliability and long-term service in harsh environments. With over 1,000,000 hours MTBF, industrial networks will stay up and running for many years to come.
Product highlights
• Up to 9 fast Ethernet (10/100) ports• Up to 3 fibre optic ports for noise-immune links up to 60 km• High performance and value • Hardened design for medium or heavier industrial networking applications • Slim packaging fits on your DIN-rail• Dual power inputs keeps you running
10.1.2. Heavy Duty
10-463
10.1. Unmanaged Ethernet Switches Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
10.1.3. Monitored Heavy Duty
table code 300 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengths
300 series - Monitored heavy Duty
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Unmanaged Monitored via OPC
4 4 - - - - - Metal 7.9 x 5.4 x 8.7 304TX-N
6 6 - - - - - 7.8 x 5.4 x 8.6 306TX-N
8 8 - - - - - 8.8 x 5.4 x 8.6 308TX-N
6 4 2 - - - - 8.9 x 5.4 x 8.7 306FX2-n-XX
6 4 - 2 - - - 8.9 x 5.4 x 8.7 306FXE2-n-XX-YY
8 6 2 - - - - 15.0 x 5.8 x 9.7 308FX2-N-XX
8 6 - 2 - - - 15.0 x 5.8 x 9.7 308FXE2-N-XX-YY
9 8 1 - - - - 13.9 x 5.8 x 8.9 309FX-N-XX
9 8 - 1 - - - 13.9 x 5.8 x 8.9 309FXE-N-XX-YY
16 16 - - - - - 18.8 x 5.8 x 8.9 316tX-n
17 16 1 - - - - 18.8 x 5.8 x 8.9 317FX-N-XX
17 16 - 1 - - - 18.8 x 5.8 x 8.9 317FXE-N-XX-YY
The N‐Tron 300 Series of hardened industrial Ethernet switches offer high reliability and full wire speed communications, in a compact size, ideal for use in mission critical, industrial, data acquisition, control and Ethernet I/O applications. These DIN‐Rail mounted switches are designed to exceed the most demanding industrial communications needs and environmental conditions, while providing high throughput and minimum downtime. The 300 Series switches configured with the N‐View option, can be monitored using standard OPC compliant HMI software in order to provide complete network monitoring and performance alarms. Handling up to 4,000 MAC addresses, these products support extremely sophisticated and complex network architectures. The 300 Series provides an affordable solution, while maintaining the simplicity of a plug‐and‐play auto sensing switch. Select 300 Series switches are supplied with the following regulatory approvals: FCC 47 CFR Part 15 Subpart B and ICES‐003 emissions, IEEE 1613 Compliance (Electric Utility Substation), ABS Type Approval (Maritime) and NEMA TS1/TS2 Compliance (Traffic Control).
Product highlights
• Supports UTP or STP Cabling• Compact Size, Small Footprint• ‐40°C to 70°C Operating Temperature• Rugged Industrial DIN‐Rail Enclosure• Full Wire Speed Communications• Redundant Power Inputs|• Auto Negotiates Speed, Duplex and MDIX• N‐View OPC Monitoring• Hardened ESD Port Protection
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksstock status:normally stocked /Not normally stocked
Discount Code L7
10
10.2. Managed Ethernet Switches
700 series
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Managed 8 8 - - - - - Metal 5.8 x 15.3 x 9.6 708tX
8 6 2 - - - - 5.8 x 15.3 x 9.6 708FX2-XX
8 6 - 2 - - - 5.8 x 15.3 x 9.6 708FXE2-XX-YY
9 8 1 - - - - 10.8 x 6.1 x 11.5 709FX-XX
9 8 - 1 - - - 10.8 x 6.1 x 11.5 709FXE-XX-YY
10 8 2 - - - - 10.8 x 6.1 x 11.5 710FX2-XX
10 8 - 2 - - - 10.8 x 6.1 x 11.5 710FXE2-XX-YY
11 8 3 - - - - 10.8 x 6.1 x 11.5 711FX3-XX
11 8 - 3 - - - 10.8 x 6.1 x 11.5 711FXE3-XX-YY
12 8 4 - - - - 10.8 x 7.9 x 11.5 712FX4-XX
12 8 - 4 - - - 10.8 x 7.9 x 11.5 712FXE4-XX-YY
14 8 6 - - - - 10.8 x 7.9 x 11.5 714FX6-XX
14 8 - 6 - - - 10.8 x 7.9 x 11.5 714FXE6-XX-YY
16 16 - - - - - 5.8 x 21.0 x 12.1 716tX
16 14 2 - - - - 5.8 x 21.0 x 12.1 716FX2-XX
16 14 - 2 - - - 5.8 x 21.0 x 12.1 716FXE2-XX-YY
table code 700 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengths
The N‐Tron 700 Series Fully Managed Industrial Fast Ethernet Switches are affordably priced to fit any networking budget while offering outstanding management and monitoring features. They are ideally suited for use as a Ring Manager or anywhere a managed switch is required. The 700 Series comes standard with fully managed features like plug‐and‐play IGMP Snooping, VLAN, QoS, Port Mirroring, Port Trunking, 802.1D RSTP, DHCP Server with Option 82 and N‐Ring. When used as a Ring Manager, N‐Tron’s N‐Ring technology provides detailed fault diagnostics, expanded ring size capacity and ˜30ms ring healing. Added control features such as full SNMP V3, Web Browser Management and N‐View OPC Remote Monitoring provide all of the tools necessary to simplify configuration and diagnostics of the N‐Tron switches. For added convenience, Models 709 and above offer an SD card slot for saving or restoring the switch configuration.
Product highlights
• ‐40°C to 70°C Operating Temperature• SNMP v1, v2, v3 and Web Configuration including MAC Filters and IGMP Groups• GUI Based DHCP Server with Option 61, Option 82 Relay• Agent, Local IP Static Addressing and IP Fallback• N‐Link Redundant N‐Ring Coupling• Port Security ‐ MAC Address Based• Advanced Features: IGMP Auto Config., VLAN, QoS, Trunking, Mirroring, 802.1D RSTP, LLDP & EtherNet/IP CIP Messaging• Ring Manager using N‐Tron’s N‐Ring Technology offers a Standard Healing Time of ˜30ms• N‐View OPC Monitoring with Fault Status for Ring Managers• Redundant Power Inputs
10-465
10.2. Managed Ethernet Switches Stock Status:Normally stocked /Not normally stocked
10
Discount code L7
sLX series
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Managed 5 5 - - - - - Metal 11.9 x 2.7 x 9.7 sLX-5Ms-1
5 3 2 - - - - 11.9 x 2.7 x 9.7 SLX-5MS-4XX
5 3 - 2 - - - 11.9 x 2.7 x 9.7 SLX-5MS-5XX
5 3 - 2 - - - 11.9 x 2.7 x 9.7 SLX-5MS-5XXL*
8 8 - - - - - 11.9 x 4.1 x 9.7 SLX-8MS-1
8 6 2 - - - - 11.9 x 4.1 x 9.7 SLX-8MS-4XX
8 6 - 2 - - - 11.9 x 4.1 x 9.7 SLX-8MS-5XX
8 6 - 2 - - - 11.9 x 4.1 x 9.7 SLX-8MS-5XXL*
8 4 4 - - - - 11.9 x 4.1 x 9.7 SLX-8MS-8XX
8 4 - 4 - - - 11.9 x 4.1 x 9.7 SLX-8MS-9XX
8 4 - 4 - - - 11.9 x 4.1 x 9.7 SLX-8MS-9XXL*
8 - Up to 4** 8 Up to 4** 11.9 x 4.1 x 9.7 SLX-8MG-1
10 7 Up to 2** 3 Up to 2** 14.0 x 4.1 x 10.9 SLX-10MG-1
16 16 - - - - - 14.0 x 5.4 x 10.9 SLX-16MS-1
18 16 Up to 2** 2 Up to 2** 14.0 x 7.3 x 10.9 SLX-18MG-1
Ring 6 6 - - - - - 10.2 x 3.8 x 7.6 SLX-6RS-1
* Single Mode Fibre 60+Km Lengths** SFP Transceivers sold separately (refer below)
table code sLX seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre 20km LengthsXX = ST or SC connectors
Fibre transceivers
speed Mode Max. Distance code
100 Mps Multimode 4km FMFIBER-SFP-4K
Singlemode 30km FSFIBER-SFP-30K
60km FSFIBER-SFP-60K
100km FSFIBER-SFP-100K
Gigabit Multimode 550m GMFIBER-SFP-500
2km GMFIBER-SFP-2K
Singlemode 10km GSFIBER-SFP-10K
30km GSFIBER-SFP-30K
50km GSFIBER-SFP-50K
80km GSFIBER-SFP-80K
Note: Up to 4 required per SLX8MG-1, SLX10MG-1 or SLX18MG-1
The SLX Series managed industrial Ethernet switches are designed to be rugged, reliable and secure. Combining compact DIN-rail packaging and protected circuitry with powerful software, our managed switches keep industrial networks up and running even in the toughest conditions.
Product highlights
• Gigabit combo ports for copper or fibre• Hardened metal enclosure• Rapid Spanning Tree (RSTP) for fast redundant ring or mesh networks • SNMPv1 and v2 network management • SNMPv3 authentication and encryption for security • SNMP notifications (traps) for report on event • Priority Queuing (QoS/CoS) for real-time operation • IGMP for Multicast filtering (snooping and querying) • VLAN for convenient traffic segregation • Broadcast and multicast storm protection • RMON and port mirroring for advanced diagnostics • Security with HTTPS, SSL, SSH, SNMPv3 and more • Easy configuration via Web, Telnet or CLI
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks10.2. Managed Ethernet Switches Stock Status:
Normally stocked /Not normally stocked
Discount Code L7
10
table code 7000 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengths
7000 series
Accessories
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type
case Dimensions h x w x D (cm)
code
MM sM MM sM
Managed 10 8 - - Up to 2* Up to 2* Metal DIN rail Mount
11.0 x 6.5 x 11.5 7010tX
12 8 2 - Up to 2* Up to 2* 10.8 x 7.9 x 11.5 7012FX2-XX
12 8 - 2 Up to 2* Up to 2* 10.8 x 7.9 x 11.5 7012FXE2-XX-YY
18 16 - - Up to 2* Up to 2* 5.8 x 21.0 x 12.1 7018tX
18 14 2 - Up to 2* Up to 2* 5.8 x 21.0 x 12.1 7018FX2-XX
18 14 - 2 Up to 2* Up to 2* 5.8 x 21.0 x 12.1 7018FXE2-XX-YY
6 4 - - Up to 2* Up to 2* 9.6 x 5.1 x 9.9 7506GX2
6 4 - - - 2 - 9.6 x 5.1 x 9.9 7506GX2-sX
6 4 - - - - 2 9.6 x 5.1 x 9.9 7506GX2-LX-10
26 24 - - 2 - - Metal 19” Rack Mount
4.6 x 40.9 x 13.7 7026TX
26 24 - - 2 - - 7026TX-AC
* SFP Transceivers sold separately (refer accessories below)
Description code
SFP (mini-GBIC) transceiver with one 1000BaseT GB copper port NTSFP-TX
SFP (mini-GBIC) transceiver with one 1000BaseSX multimode GB fibre optic port ntsFP-sX
SFP (mini-GBIC) transceiver with one 1000BaseLX singlemode GB fibre optic port ntsFP-LX-ZZ
Configuration card for backup/restore NTCD-128
The N‐Tron 7000 Series is ideal for use as either a fully managed fibre optic Ring Manager or Ring Member. These gigabit capable industrial Ethernet switches carry N‐Tron’s exclusive N‐Ring™ technology providing detailed fault diagnostics, expanded ring size capacity and ˜30ms ring healing. When using all N‐Tron fully managed switches in a ring, a detailed ring map and fault location chart will be provided on the Ring Manager’s web browser and OPC Server to identify the health status of the ring. In addition to N‐Ring, the 7000 Series offers fully managed features such as IGMP Snooping, VLAN, QoS, Port Mirroring, Port Trunking, 802.1D‐2004 fast RSTP, DHCP and N‐Ring. For ease of monitoring, configuration and diagnostics N‐Tron’s N‐View OPC Server Software, SNMP V3 and Web Browser Management come standard on all 7000 Series Switches. N‐View can be combined with popular HMI software packages to add network traffic monitoring, trending and alarming to any application using N‐Tron switches.
Product highlights
• Auto Sensing 10/100BaseTX, Duplex and MDIX• ‐40°C to 70°C Operating Temperature• SNMP v1, v2, v3 and Web Configuration including MAC Filters and IGMP Groups• GUI Based DHCP Server with Option 61, Option 82 Relay• Agent, Local IP Static Addressing and IP Fallback• N‐Link Redundant N‐Ring Coupling plus• N‐View OPC Monitoring with Fault Status for Ring Managers• Port Security ‐ MAC Address Based• Advanced Features: IGMP Auto Config., VLAN, QoS, Trunking, Mirroring, 802.1D RSTP, LLDP, & EtherNet/IP CIP Messaaging• Ring Manager using N‐Tron’s N‐Ring Technology offers a Standard Healing Time of ˜30ms• Redundant Power Inputs
10-467
10.2. Managed Ethernet Switches Stock Status:Normally stocked /Not normally stocked
10
The EL212F is a 12 port (8 + 4G) layer 2 industrial Ethernet switch with managed capabilities, designed to meet the extreme requirements of power substations, traffic control, railway and other harsh environments. This industrial switch meets the needs of the most demanding applications by combining high performance and security of enterprise-class switches with rugged DIN-rail packaging and protected circuitry. With 8 fast Ethernet SFP ports, fibre or copper links can be mixed and matched on the fly to provide the ultimate in port flexibility. Sixnet exclusive mounting features also enables quick DIN-rail or direct panel deployment. The end result is a managed switch that provides users with the lowest cost of ownership of any industrial Ethernet switch in its class.
Product highlights
• IEC 61850/IEEE 1613 compliance ensures applications stay running in the toughest environments • Enterprise-class functionality and security future proofs the network • Powerful management and monitoring simplifies deployment and provides fault isolation • Extreme port flexibility allows for seamless field configuration and upgrade • Up to 12 fibre optic ports offer the ultimate in noise immunity • DIN-rail or direct panel mounting simplifies installation• IEC 61850 & IEEE 1613 for utility substation automation and other power applications • NEMA TS-2 for traffic control systems • EN 50155 & EN 50121-4 for railway installations
Discount code L7
EL212F series
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre
case type (Din-rail)
case Dimensions h x w x D (cm)
code
Managed (Single AC/DC Power Input)
12 Up to 8* Up to 12* Up to 4* Up to 4* Metal 16.5 x 6.5 x 16.0 EL212F-AC-V1
Managed (Dual 18-59VDC Power)
12 Up to 8* Up to 12* Up to 4* Up to 4* Metal 16.5 x 6.5 x 16.0 EL212F-DC-V1
* SFP Transceivers sold separately (refer below)
Fibre transceivers
speed Mode Max. Distance Port compatibility code
10/100 Mbps Copper RJ45 100m Ports 1-8, 11,12 FCOPPER-SFP-100
100 Mps Multimode 4km All SFP Ports FMFIBER-SFP-4K
Singlemode 30km All SFP Ports FSFIBER-SFP-30K
60km All SFP Ports FSFIBER-SFP-60K
100km All SFP Ports FSFIBER-SFP-100K
Gigabit Multimode 550m Ports 9-12 GMFIBER-SFP-500
2km Ports 9-12 GMFIBER-SFP-2K
Singlemode 10km Ports 9-12 GSFIBER-SFP-10K
30km Ports 9-12 GSFIBER-SFP-30K
50km Ports 9-12 GSFIBER-SFP-50K
80km Ports 9-12 GSFIBER-SFP-80K
* Up to 4 required per SLX8MG-1, SLX10MG-1 or SLX18MG-1
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks10.2. Managed Ethernet Switches Stock Status:
Normally stocked /Not normally stocked
10
Discount code L7
EL228 series
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre
case type (Din-rail)
case Dimensions h x w x D (cm)
code
Managed (Single AC/DC Power Input)
28 Up to 24* Up to 26* 4 Up to 2* Metal 4.5 x 43.9 x 30.5 EL228-A0-1
Managed (Dual AC/DC Power Input)
28 Up to 24* Up to 26* 4 Up to 2* Metal 4.5 x 43.9 x 30.5 EL228-AA-1
Managed (Single 18-59VDC Power Input)
28 Up to 24* Up to 26* 4 Up to 2* Metal 4.5 x 43.9 x 30.5 EL228-D0-1
Managed (Dual 18-59VDC Power Input)
28 Up to 24* Up to 26* 4 Up to 2* Metal 4.5 x 43.9 x 30.5 EL228-DD-1
* SFP Transceivers sold separately (refer below)
Fibre transceivers
speed Mode Max. Distance Port compatibility code
100 Mps Multimode 4km Ports 1-26 FMFIBER-SFP-4K
Singlemode 30km Ports 1-26 FSFIBER-SFP-30K
60km Ports 1-26 FSFIBER-SFP-60K
100km Ports 1-26 FSFIBER-SFP-100K
Gigabit Multimode 550m Ports 25,26 GMFIBER-SFP-500
2km Ports 25,26 GMFIBER-SFP-2K
Singlemode 10km Ports 25,26 GSFIBER-SFP-10K
30km Ports 25,26 GSFIBER-SFP-30K
50km Ports 25,26 GSFIBER-SFP-50K
80km Ports 25,26 GSFIBER-SFP-80K
The Sixnet EL228 is a 28 port (24 + 4G) managed industrial Ethernet switch designed to meet the extreme requirements of power substations, traffic control, railway and other harsh environments. It combines the high performance and security of an enterprise-class switch with rugged packaging and protected circuitry to meet the needs of the most demanding applications.
Product highlights
• KEMA tested and approved for IEC61850 and IEEE 1613• Enterprise-class functionality and security future proofs the network• Powerful management & monitoring simplifies deployment and provides fault isolation• Extreme port flexibility allows for seamless field configuration and upgrade• Up to 26 fiber optic ports offer the ultimate in noise immunity• Universal mounting (patent pending) simplifies ordering and deployment• IEC 61850 & IEEE 1613 for utility substation automation and other power applications• NEMA TS-2 for traffic control systems • EN 50155 & EN 50121-4 for railway installations
10-469
10.2. Managed Ethernet Switches Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
7900 series
order codes – Modules (up to 4 per cPU + Backplane)
order codes – cPU & Backplane
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM MM sM
Managed 6 6 - - - - - Metal 13.0 x 23.8 x 16.0 (CPU + Backplane + 4 x Modules)
9006tX
2 - 2 - - - - 9002FX-XX
2 - - 2 - - - 9002FXE-XX-YY
4 - 4 - - - - 9004FX-XX
4 - - 4 - - - 9004FXE-XX-YY
table code 7900 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengths
Description code
CPU Module with two (2) gigabit SFP ports - transceivers sold separately* 7900cPU
Five (5) Slot Backplane (requires 7900CPU Module - sold separately) 9000BP
* SFP Transceivers sold separately (refer accessories below)
Accessories
Description code
SFP (mini-GBIC) transceiver with one 1000BaseT GB copper port NTSFP-TX
SFP (mini-GBIC) transceiver with one 1000BaseSX multimode GB fibre optic port ntsFP-sX
SFP (mini-GBIC) transceiver with one 1000BaseLX singlemode GB fibre optic port ntsFP-LX-ZZ
Filler Panel (required to fill vacant slots) 9000B-FP
Panel Mount Kit 9000-PM
Metal DIN-Rail Clip (note: one included, can accommodate two (2) additional clips—3 total—for increased stability)
9000-UtA107
The N-Tron® 7900 Industrial Ethernet Modular Switch is designed to deliver optimum performance with maximum network versatility. Its flexible modular format allows customization with a variety of fibre and copper port modules. As the network evolves, port configurations can easily be changed to adapt to new communication requirements. The fully managed series is ideal for manufacturing, utilities, transportation, energy generation, wastewater and other extreme networking environments that demand high reliability, superior noise immunity and support across extended distances.
Product highlights
• 4 slot modular switch• Requires 2 SFP gigabit CPU module (transceivers sold separately)• -20oC to 70oC operating temperature• Onboard temperature sensor• ESD & surge protection diodes on all copper ports• Auto sensing 10/100BaseTX, duplex & MDIX• Store-and-forward technology• Rugged DIN-rail enclosure• Redundant power inputs (10-30 VDC)• Configurable bi-colour fault status LEDs• Advanced Features: IGMP Auto Config., VLAN, QoS, Trunking, Mirroring, 802.1D RSTP, LLDP, & EtherNet/IP CIP Messaaging• Ring Manager using N‐Tron’s N‐Ring Technology offers a Standard Healing Time of ˜30ms
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks10.2. Managed Ethernet Switches Stock Status:
Normally stocked /Not normally stocked
Discount Code L7
10
nt24k series
order codes – cPU & Backplane
Description case Dimensions h x w x D (cm)
code
Managed Industrial Ethernet Switch; modular DIN rail design with 2 expansion slots; redundant 18-49VDC power input
15.2 x 17.22 x 11.65 nt24k-Dr16-Dc
Managed Industrial Ethernet Switch; modular DIN rail design with 2 expansion slots; 90-264VAC / 90-300VDC power inputs
NT24K-DR16-AC
Managed Industrial Ethernet Switch; modular DIN rail design with 3 expansion slots; redundant 18-49VDC power input
15.2 x 21.46 x 11.65 nt24k-Dr24-Dc
Managed Industrial Ethernet Switch; modular DIN rail design with 3 expansion slots; 90-264VAC / 90-300VDC power inputs
NT24K-DR24-AC
1U rackmount 3-slot modular Gigabit switch with one redundant 18-49 VDC power input
4.8 x 44.5 x 32 NT24K-DC1
1U rackmount 3-slot modular Gigabit switch with two redundant 18-49 VDC power inputs
NT24K-DC2
1U rackmount 3-slot modular Gigabit switch with one 90-264 VAC/90-300 VDC power input
NT24K-AC1
1U rackmount 3-slot modular Gigabit switch with two 90-264 VAC/90-300 VDC power input
NT24K-AC2
1U rackmount 3-slot modular Gigabit switch with one each 90-264 VAC/90-300 VDC and 18-49 VDC power inputs
NT24K-AC1-DC1
nt24k-Dr16-xx
nt24k-Dr24-xx
nt24k-xxx
The NT24k Series is a modular managed Gigabit Ethernet industrial switch. With up to 24 Gigabit Ethernet ports and a flexible modular format for different configuration options, the NT24k switches are designed to handle the most challenging industrial environments with high reliability and wire-speed performance.
Available in rackmount and DIN rail models, the NT24k switches provide versatility through Gigabit and 100Base connectivity options in both copper and fibre. With all Gigabit capability and a versatile array of connectivity options, the NT24k switches deliver configuration flexibility that meets industrial networking requirements across industries such as factory automation, utilities, video surveillance, security, transportation and alternative energy.
The NT24k includes expanded shock and vibration tolerances and an extreme operating temperature range. It also offers redundant power input options, configuration backup and an onboard temperature sensor to ensure maximum reliability. Its full set of management features include Web browser management, SNMP, Jumbo Frame support, port trunking, port mirroring, DHCP client, 802.1Q VLAN, 802.1p QoS and other features. In addition, N-Ring advanced ring technology restores network communication within ~30ms of fault detection. Robust remote monitoring capabilities make management easy.
Product highlights
• All Gigabit Modular Design• Up to 24 Port Connections• High Environmental Specifications• N-Ring Advanced Ring Technology• Robust Remote Monitoring• Smart Plug-and-Play Operation• -40o C to 85o C operating temperature• Dual power input options ESD & surge protection diodes on all copper ports • Auto-sensing 10/100/1000BaseT(X), duplex and MDIX • USB configuration port • Configurable alarm contact • Optional backup/restore configuration device
10-471
10.2. Managed Ethernet Switches Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
order codes – Port Modules
order codes – transceivers
Description code
8-port 10/100/1000BaseT module nt24k-tX8
Slide-in module with 8 100BaseFX multimode fiber ports, 2km (SC or ST) nt24k-FX8-XX
Slide-in module with 8 100BaseFX singlemode fiber ports (SC or ST) NT24K-FXE8-XX-YY
Slide-in module with 8 1000BaseFX multimode fiber ports, 550m (SC) nt24k-GX8-sc
Slide-in module with 8 1000BaseFX singlemode fiber ports (SC) NT24K-GXE8-SC-ZZ
Slide-in module with 8 SFP expansion slots; supports 1000Base SFP transceivers* nt24k-sFP8
Slide-in module with 8 dual mode SFP expansion slots; supports 100Base or 1000Base SFP transceivers* NT24K-SFP-DM8
* SFP Transceivers sold separately (refer below)
Description code
100BaseFX multimode fiber SFP pluggable mini-GBIC transceiver(LC style connector, 2km)**
ntsFP-FX
100BaseFX singlemode fiber SFP pluggable mini-GBIC transceiver(LC style connector)**
NTSFP-FXE-YY
1000BaseT copper SFP pluggable mini-GBIC transceiver ntsFP-tX
1000BaseSX multimode fiber SFP pluggable mini-GBIC transceiver ntsFP-sX
1000BaseLX singlemode fiber SFP pluggable mini-GBIC transceiver NTSFP-LX-ZZ
where: XX = ST or SC connector (ST not available on some GX modules); YY = 15, 40, or 80 for FX singlemode, blank for multimode; ZZ = 10, 40, or 80 for GX singlemode. **For use with SFP DM8 module only
Accessories
Description code
Filler panel (required to fill vacant module slots) nt24k-FP
Panel mount kit NT24-PMK
Configuration recovery device ntcD-cFG
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks10.2. Managed Ethernet Switches Stock Status:
Normally stocked /Not normally stocked
Discount Code L7
10
EL326 series
order codes
type total Ports GiG copper GiG Fibre optional 10 GiG Ports
case Dimensions h x w x D (cm)
code
Managed (Single AC/DC Power Input)
26 24 Up to 4* Up to 2* 4.5 x 43.9 x 30.5 EL326-AO-1
Managed (Dual AC/DC Power Input)
26 24 Up to 4* Up to 2* 4.5 x 43.9 x 30.5 EL326-AA-1
Managed (Single 18-59VDC Power Input)
26 24 Up to 4* Up to 2* 4.5 x 43.9 x 30.5 EL326-DO-1
Managed (Dual 18-59VDC Power Input)
26 24 Up to 4* Up to 2* 4.5 x 43.9 x 30.5 EL326-DD-1
* SFP Transceivers sold separately (refer below)
Fibre transceivers
speed Mode Max. Distance Port compatibility code
Gigabit Multimode 550m Ports 21-24 GMFIBER-SFP-500
2km Ports 21-24 GMFIBER-SFP-2K
Singlemode 10km Ports 21-24 GSFIBER-SFP-10K
30km Ports 21-24 GSFIBER-SFP-30K
50km Ports 21-24 GSFIBER-SFP-50K
80km Ports 21-24 GSFIBER-SFP-80K
10Gigabit Multimode 500m 10G Port 25,26 10GFIBR-XFP-500
Singlemode 10km 10G Port 25,26 10GFIBR-XFP-10K
40km 10G Port 25,26 10GFIBR-XFP-40K
80km 10G Port 25,26 10GFIBR-XFP-80K
Accessories
Description code
10G expansion module with fibre XFP port (transceiver sold separately) 10GXFP-MOD
Stacking cable, 30cm STACKCBL30
Stacking Cable, 130cm STACKCBL130
The EL326 is a Layer 3 rack-mount managed industrial Ethernet switch with advanced capabilities, designed to meet the performance requirements of power substations, traffic control, railway and other mission-critical networks. Combining the high availability and security of an enterprise-class switch with rugged packaging and protected circuitry, the EL326 easily handles even the most bandwidth intensive applications.
Product highlights
• Industrial-grade Layer 3 hardware functionality increases multi-service network performance • 10Mb/s to 10Gb/s Ethernet provides flexible deployment options • IPv4 & IPv6 management delivers infrastructure sustainability • Enterprise-class functionality and advanced security future proofs the network • Stackable design provides high scalability and investment protection
10-473
10.2. Managed Ethernet Switches Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
Military rated
order codes
type total Ports Fast Ethernet 10/100
Gigabit Ethernet 10/100/1000
connectors case code
Managed 24 4 20 MIL-DTL-38999 Aluminium MIL-324-1
26 4 22 MIL-326-1
8 8 - ET-8MS-MIL-1
8 - 8 ET-8MG-MIL-1
Unmanaged 8 8 - ET-8ES-MIL-1
8 - 8 ET-8EG-MIL-1
8 8 - Threaded Fully-potted EB-GT-8ES-1EP
5 5 - Quick-Connect Fibre-reinforced ET-5ES-IP67-E
rugged, proven hardwareCommercial off-the-shelf (COTS) solutions
• IP67/IP65/NEMA 6 water, oil and dust-tight designs • Protected circuitry withstands noise, transients and surges • Wide operating temperatures with -40 to 75Deg.C
Full Military-rated switchesField tested and proven to support the harshest defence applications
• MIL-STD-810F (shock, vibration, temp, humidity, sand, dust, salt, fog elevation & explosive atmosphere) • MIL-STD-461F (emissions and immunity) • MIL-STD-1275D (power protection) • MIL-STD-108E (steam and water) • MIL-DTL-38999 connector system • Heavy-duty aluminium packaging
Potted, compact iP67 switchesIndustrial rated to be water-tight and shock resistant
• MIL-STD-1275B (power protection) • Quick-connect reverse bayonet and threaded connector options • Water, oil and dust proof
rugged, proven hardware
• Bombers, transports, UAVs and other aircraft • Missile delivery systems • Navel vessels and offshore platforms • Land vehicles with fluctuating power • Ground support facilities
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksstock status:normally stocked /Not normally stocked
Discount Code L7
10
10.3. IP67 Rated Ethernet Switches10.3.1. Unmanaged
100 series - Unmanaged
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type
case Dimensions h x w x D (cm)
code
MM sM MM sM
Unmanaged 5 5 - - - - - Metal 12.7 x 11.0 x 4.6 105M12
8 8 - - - - - 16.9 x 16.9 x 4.6 108M12
Accessories
Description code
Cat5E STP Cable with Straight M12 to Straight M12 Connector, Shielded CAT5E-M12-M12-X
Cat5E STP Cable with Straight M12 to RJ-45 Connector, Shielded CAT5E-M12-RJ45-X
Cat5E STP Cable with Straight M12 Connector to bare end, Shielded CAT5E-M12-X
Cat5E STP Cable with 90º M12 to Straight M12 Connector, Shielded CAT5E-RM12-M12-X
Cat5E STP Cable with 90º M12 to 90º M12 Connector, Shielded CAT5E-RM12-RM12-X
Cat5E STP Cable with 90º M12 to RJ-45 Connector, Shielded CAT5E-RM12-RJ45-X
Cat5E STP Cable with 90º M12 to bare end, Shielded CAT5E-RM12-X
Power Cable, M12 A-Coded Straight Female Connector to bare end, Shielded PWR-M12-A-X
Power Cable, M12 A-Coded 90º Female Connector to bare end, Shielded PWR-RM12-A-X
DIN-Rail kit, two isolated plastic clips M12DRC-ISO
DIN-Rail kit, two metal clips M12DRC-MTL
X = Lenght in feet
Ideal for mission critical data acquisition, control and Ethernet I/O applications with severe environmental conditions, the 105M12 & 108M12 unmanaged fast Ethernet Switches are IP67 rated for protection against dust, low and high pressure water jets and temporary immersion in water. These units utilize standard M12 D-Coded connectors for either five or eight 10/100BaseTX copper ports and carry extended operating temperatures, high MTBF and other specifications for unbeatable reliability. Standard voltage models are ABS and DNV approved for maritime environments and some models are EN50155 certified for railway applications.
Product highlights
• Unmanaged Operation• IP67 Rated Hardened Metal Enclosure• Bulkhead Mountable (DIN‐Rail Mounting Option Available)• Protected Against Low/High Pressure Water Jets & Temporary Immersion in Water• Totally Protected Against Dust Ingress• ‐40°C to 70°C Operating Temperature• Supports up to 2,000 MAC Addresses• Full/Half Duplex Operation• Auto Sensing Speed and Flow Control• ESD Protection Diodes on all Ports• Surge Protection Diodes on Power Inputs• Redundant Power Inputs
10-475
10.3. IP67 Rated Ethernet Switches Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
10.3.2. Managed
700 series - Managed
order codes
type total Ports
10/100 copper
100 Fibre GiG copper
GiG Fibre case type
case Dimensions h x w x D (cm)
code
MM sM MM sM
Managed 8 8 - - - - - Metal 16.9 x 16.9 x 4.6 708M12
Accessories
Description code
Cat5E STP Cable with Straight M12 to Straight M12 Connector, Shielded CAT5E-M12-M12-X
Cat5E STP Cable with Straight M12 to RJ-45 Connector, Shielded CAT5E-M12-RJ45-X
Cat5E STP Cable with Straight M12 Connector to bare end, Shielded CAT5E-M12-X
Cat5E STP Cable with 90º M12 to Straight M12 Connector, Shielded CAT5E-RM12-M12-X
Cat5E STP Cable with 90º M12 to 90º M12 Connector, Shielded CAT5E-RM12-RM12-X
Cat5E STP Cable with 90º M12 to RJ-45 Connector, Shielded CAT5E-RM12-RJ45-X
Cat5E STP Cable with 90º M12 to bare end, Shielded CAT5E-RM12-X
Power Cable, M12 A-Coded Straight Female Connector to bare end, Shielded PWR-M12-A-X
Power Cable, M12 A-Coded 90º Female Connector to bare end, Shielded PWR-RM12-A-X
Serial cable, DB-9 to M12 5 ft, shielded SERIAL-DB9-M12
Serial cable, DB-9 to 90o M12, 5 ft, shielded SERIAL-DB9-RM12
X = Lenght in feet
Housed in an IP67‐rated metal enclosure, the fully managed 708M12 is ideally suited for connecting Ethernet enabled devices in railway, industrial, marine and security applications. The IP67‐rated enclosure provides protection against dust, low and high pressure water jets and temporary immersion in water. All 708M12 models are EN50155 certified for railway applications. Standard models have ABS and DNV Type Approval for maritime environments.
Product highlights
• IP67 Rated for Protection against dust, water jets & temporary immersion in water• ‐40°C to 80°C Operating Temperature• SNMP v1, v2, v3 & Web Configuration including MAC Filters & IGMP Groups• GUI Based DHCP Server with Option 61, Option 82 Relay• Agent, Local IP Static Addressing & IP Fallback• N‐Link Redundant N‐Ring Coupling• Port Security ‐ MAC Address Based• Advanced Features: IGMP Auto Config., VLAN, QoS, Trunking, Mirroring, 802.1D RSTP, LLDP, & EtherNet/IP CIP Messaging• Ring Manager using N‐Tron’s N‐Ring Technology offers a Standard Healing Time of ˜30ms• N‐View OPC Monitoring with Fault Status for Ring Managers• Redundant Power Inputs
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksstock status:normally stocked /Not normally stocked
Discount Code L7
10
10.4. Wireless Radio Ethernet
700 series
Accessories
order codes
Description code
Panel mount kit for use with 702-W Wireless Radio 702-w-PM
Pole Mount Kit for 702M12-W Radio 702M12-PK
702-WLow loss CA-400 coaxial cable with (1) RP-TNC connector and (1) N-male connector ANT-CAB-400-N-RPSMA-X
702-W antenna bulkhead extension cable set; each cable includes (1) straight RP-SMA bulkhead jack and (1) 90° RP-SMA plug (package of 3)
ANT-CAB-195-RPSMA-RPSMA-X
702M12-W Low Loss Coaxial Antenna Cable (1 RP-TNC and 1 N-male connector) ANT-CAB-400-N-RPTNC-X
2.4GHz 12dBi mini directional antenna and pole mount bracket included ANT-MD24-12
2.4GHz 16dBi panel directional antenna and pole mount bracket included ANT-PAD24-16
5.8GHz, 19dBi panel directional antenna N-female connector and pole mount bracket included ANT-PAD58-19
5.8 GHz parabolic dish 32dBi directional antenna and pole mount bracket included ANT-PD58-32
2-6GHz quarter wave lightning arrestor (N-female to N-female, less than 0.2dB insertion loss, IP65, -40° to 85°C)
ANT-LA6-NFF
Low loss CA-400 coaxial cable with (2) N-female connector (for use with the ANT-LA6-NFF lightning arrestor)
ANT-CAB-400-N-X
Description case type (Din-rail)
case Dimensions h x w x D (cm)
code
1 Port (10/100BaseTX) Industrial Wireless Radio with three MIMO antennas
Metal 13.2 x 18.9 x 3.9 702-w
IP67-rated 1-port (10/100BaseTX w/M12 D-coded female connectors) Industrial Wireless Radio with three MIMO antennas, bulkhead mountable
Metal 17.2 x 17.2 x 4.6 702M12-W
The 702W & 702M12-W Industrial Wireless Ethernet Radios offers unprecedented throughput in industrial wireless applications. IEEE 802.11n support allows these radios to utilize three antennas and Multiple In, Multiple Out (MIMO) technology for increased throughput. They also support 802.11a/b/g compatibility for existing wireless networks. The radios can be configured to operate as a wireless Station, Station WDS, Access Point, or Access Point WDS and will operate in either Bridge or Router mode within the network. Power over Ethernet (PoE) technology allows the 702W or 702M12-W to receive power through the Cat5e cable from a PoE sourcing device such as the105TXPOE Switch. The 702M12-W is IP67 rated with M12 connectors which provides complete protection against dust, water jets and temporary immersion in water making it ideal for outdoor, wash down, or extremely dusty environments.
Product highlights
• One 10/100BaseTX RJ‐45 Port• Three Antennas for 3x3 MIMO Operations• 802.3af PoE Powered Device• ‐40°C to 70°C Operating Temperature• Web Browser Management• Data Rates: Legacy 802.11a/b/g = 1‐54Mbps 802.11n = up to 300Mbps• Network Modes: Bridge or Router• Wireless Modes: Station, Station WDS, Access Point, Access Point WDS• Range: Indoor greater than 300m• Outdoor greater than 60km• Security: 802.11i with AES‐CCM & TKIP Encryption 802.1x, 64/128 bit WEP• Redundant Power Inputs
10-477
10.4. Wireless Radio Ethernet
10
typical scenario - Basic Bridge
typical scenario - wDs Peering
Access Point:The “access point” mode allows the 702-W to serve as a wireless switch for the wireless stations attached to it. Wireless access points are commonly used to create one wireless local area network (WLAN) that spans an area around the access point. Each access point typically supports up to 253 stations.
In this scenairio, each 702M12-W has been configured as a peer of selected other 702M12-W(s) by using the MAC Addresses of the select unit(s). This allows forklifts or other mobile wireless devices to maintain communication seamlessly as they move from the area covered by one 702M12-W into the area covered by the next 702M12-W.
station:In “station” configuration, the 702-W is used to connect a single device (MAC address) to a wireless access point.
For added security, the 702-W supports WEP, WPATM, and WPA2TM. WPA and WPA2, TKIP (Temporal Key Integrity Protocol) and CCMP (counter mode with Cipher Block Chaining Message Authentication Code Protocol) are available.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworksstock status:normally stocked /Not normally stocked
Discount Code L7
10
10.5. Power over Ethernet (PoE)10.5.1. PoE Switches10.5.2. PoE Injectors
100 series - PoE switches
100 series - PoE injectors
order codes
order codes
type total Ports Ports w/PoE 10/100 (copper)
Uplink port 10/100 (copper)
Uplink port 10/100 (Fibre)
case type (Din-rail)
case Dimensions h x w x D (cm)
code
MM sM
PoE Switch 5 4 1 - - Metal 9.7 x 3.8 x 9.0 105tX-PoE
5 4 - 1 - Metal 9.7 x 3.8 x 9.0 105FX-XX-POE
5 4 - - 1 Metal 9.7 x 3.8 x 9.0 105FX-XX-YY-POE
type total Ports 4 rJ45 10/100 BasetX Ports in
4 rJ45 with PoE out
supply Power case Dimensions h x w x D (cm)
code
PoE Injector 8 4 4 48VDC 9.7 x 3.8 x 9.0 100-PoE4
table code 100 seriesMM = Multimode Fibre up to 4km LengthssM = Single Mode Fibre XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengths
The N-Tron ® 105TX-POE Unmanaged Industrial Ethernet Switch is designed to trasmit power, along with data, over an Ethernet network and is ideal for PoE capable devices where running an AC power feed is either not possible or cost effective. This feature allows an end user to power a PoE camera, wireless access point, or any other PoE capable device without the need for running separate wires for power. This also allows the ability for a centralized battery backupfor all these devices.
Product highlights
• Full IEEE 802.3 and 802.3af Compliance• American Bureau of Shipping (ABS) Type Approval• EN50155 for Railway applications• Unmanaged Operation• -40ºC to 85º Operating Temperature• Automatic Detection of Connected PoE Devices• Support for Full/Half Duplex Operation• Auto-sensing Duplex, Speed, and MDIX• Up to 1.0 Gb/s Maximum Throughput• Supports 15.4 Watts per port (13 Watts at the PD)• Redundant Power Inputs (46-49 VDC)• Hardened Metal DIN-Rail Enclosure
The 100-POE4 Industrial PoE Mid-Span Injector is designed to transmit power along with data over an Ethernet network. It is ideal for powering PoE capable devices where running an AC power feed is either not possible or cost effective. PoE allows an end user to power a PoE camera, wireless access point, or any other PoE capable device without the need for running separate wires for power. This also allows the ability for a centralized battery backup for all these devices.
Product highlights
• Compact, Space Saving Package• IEEE 802.3af Compliance• American Bureau of Shipping (ABS) Type Approval• EN50155 for Railway applications • Four 10/100BaseTX RJ-45 Ports (Data In)• Four 10/100BaseTX RJ-45 PoE Ports (Data & Power Out)• Unmanaged Operation• Extended Environmental Specifications• -40¼C to 85¼ Operating Temperature• Automatic Detection of Connected PoE Devices• Up to 0.8 Gb/s Maximum Throughput• Full Wire Speed Communications• Supports 15.4 Watts per port (13 Watts at the PD)• Redundant Power Inputs (46-49 VDC)• Power Fault Status LED• LED PoE Status Indication• Hardened Metal DIN-Rail Enclosure
10-479
10.5. Power over Ethernet (PoE) Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
10.5.2. PoE Injectors
EB series - PoE injectors
100 series - PoE splitters
order codes
order codes
type total Ports 4 rJ45 10/100 BasetX Ports in
4 rJ45 with PoE out
supply Power case Dimensions h x w x D (cm)
code
PoE Injector 2 1 1 24VDC 10.7 x 2.5 x 8.3 EB-PsE-24V-1A
4 2 2 48VDC 10.7 x 2.5 x 8.3 EB-PsE-48V-2A
Description output case type (Din-rail) case Dimensions h x w x D (cm)
code
Ethernet PoE splitter 12VDC Metal 10.2 x 2.6 x 9.8 100-POE-SPL-12
24VDC Metal 10.2 x 2.6 x 9.8 100-POE-SPL-24
48VDC Metal 10.2 x 2.6 x 9.8 100-POE-SPL-48
10.5.3. PoE SplittersDiscount code L7
The Power over Ethernet splitters are designed to accept Ethernet with PoE via Cat5 cable and output power via terminal block and Ethernet via RJ-45. This allows devices which are not PoE capable to be connected and powered by a Cat5 cable. The 100-POE-SPL also allows legacy devices which are not PoE capable to be deployed without the need to provide a dedicated power supply. The 100-POE-SPL is ideal for use with the 105TX-POE, 105FX-POE, 100-POE4 or other PoE sourcing equipment. The 100-POE-SPL can be ordered with 12, 24, or 48 volt DC output.
Product highlights
• Compact, Space Saving Package• IEEE 802.3af Compliant• One RJ-45 PoE Port (Data & Power In)• One RJ-45 Port (Data Out)• Unmanaged Operation• -40ºC to 85ºC Operating Temperature• Supports up to 15.4 Watts (Cable and PSE Dependent)• Built in Transient Voltage Suppression• Power Status LED• Hardened Metal DIN-Rail Enclosure
The industrial PoE power injectors add 48 VDC power into 1, 2 or 4 Ethernet ports so that you can pass power and data over the same wire to your Ethernet devices in the field. The 24V powered model steps up your 24 VDC for sourcing 1 PoE port so no separate DC/DC converter is required. The 48V powered models offer either 2 or 4 port injectors in one to save space and money. Both are ultra-rugged, reliable and easy to use.
Product highlights
• Compact, Space Saving Package• IEEE 802.3af Compliance• American Bureau of Shipping (ABS) Type Approval (100-POE4)• EN50155 for Railway applications (100-POE4)• Unmanaged Operation• Extended Environmental Specifications• -40ºC to 85º Operating Temperature (100-POE4)• Automatic Detection of Connected PoE Devices• Up to 0.8 Gb/s Maximum Throughput• Full Wire Speed Communications• Supports 15.4 Watts per port (13 Watts at the PD) (100-POE4)• Redundant Power Inputs
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks
10
stock status:normally stocked /Not normally stocked
10.6. Cellular Modems & Routers
M2M cellular connectivity
industrialPro 6000 series
order codes
Description serial Ports Ethernet Ports cellular network code
HSPA Cellular Router 1 1 3G / Next G / GSM sn-6801-GE
HSPA Cellular Router 1 5 3G / Next G / GSM sn-6821-GE
HSPA Cellular Router with PoE 1 1 3G / Next G / GSM SN-6801EB-GE
Red Lion’s Sixnet’s IndustrialPro M2M industrial cellular routers provide secure, cost-effective wireless connectivity to remote locations and assets. As reliable primary WAN connections or a backup to existing network links, the IndustrialPro routers are ideally suited for harsh industrial environments where space may be limited and wired connectivity is not feasible.
Uninterrupted, cost-effective communications for remote sites
• Rugged compact design optimizes space • Local web-based management and administration • Fully configurable router and firewall
Accessories
Description code
5dB Panel Mount Antenna with 5m cable Ant5DB5M
7dB Panel Mount Antenna with 5m cable Ant7DB5M
Discount code L7
10-481
10.6. Cellular Modems & Routers
10
sixView Management softwareProduct highlights
• Remote site management lowers total cost of ownership• Mass configuration simplifies and accelerates deployment• Configurable parameters enhance security• Manage thousands of devices from a central web-based console
SixView ManagerTM is flexible remote management software designed to increase productivity and reduce cost for organizations using Sixnet industrial-grade wireless routers. With a web-based console and customized dashboard, users are able to remotely access, configure and manage critical device information for several, even thousands, of Sixnet IndustrialPro and EnterprisePro Routers from a central location.
Key metrics such as signal strength, data usage, connectivity, IP addresses and alarms are displayed in real time to help simplify troubleshooting. Administrators can remotely set user-based access control parameters, upgrade firmware, configure VPNs and update firewall settings thereby saving time and reducing maintenance costs.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
10. EthErnEt nEtworks10.6. Cellular Modems & Routers
10
hardware & software requirements
software hardware
Web browser (examples: Firefox; Web Kit (Chrome, Safari); Internet Explorer)
Pentium 4, 3GHz or higher
Linux server (examples: Red Hat Enterprise 5; Centos Fedora) 4GB RAM or higher
Apache 2.x 120GB hard drive or higher (multi-drive RAID recommended)
MySQL 5.0.45 or higher
PHP 5.3.3 or higher
Features & Benefits
Mass Configuration & Auto Provisioning
• Saves time and deployment costs• Prevents unwanted access with enhanced security • Initial unit configuration • Firmware updates • VPN configuration • Firewall policy enforcement • Mass unit migration• Grouping control• Import devices
remote troubleshooting & control
• Saves site visits• Enables faster trouble shooting • Change and update firmware • Change or update policies • Remote reboot • Delete or modify user access rights
remote Administration of Multiple Devices
• Facilitate security compliance • Simplify ease of use • Configuration changes • Job scheduling (single or multi device) • Intent-to-edit protections • Customise data grid views • Control user permissions (control editing capabilities)
remote Monitoring & reporting of key Metrics
• Provide real-time status• Enable proactive decision making • Up-time • Utilization • Signal strength • Firmware version – ESN, MDN or IMEI – IP address
order codes
Description code
SixView Manager – 25 Licenses SN-SVM-25
SixView Manager – Unlimited Device Licenses SN-SVM-UL
stock status:normally stocked /Not normally stocked
Discount code L7
10-483
Stock Status:Normally stocked /Not normally stocked
Discount Code L7
10
10.7. Media Converters
order codes
order codes
type Description code
Serial / Fibre Serial to Multi-mode Fibre Optic Converter. (RS232/RS485/RS422) sEr-485-FXc
Ethernet / Fibre 1 Port 10/100BaseTX to 1 Port 100BaseFX Media Converter (multimode fibre optic port, 4 km)
102Mc-XX
1 Port 10/100BaseTX to 1 Port 100BaseFX Media Converter (singlemode fibre optic port, up to 80 km)
102McE-XX-YY
1 Port 10/100/1000BaseT to 1 Port 1000BaseSX Media Converter multimode fibre
1002MC-SX
1 Port 10/100/1000BaseT to 1 Port 1000Base LX Media Converter singlemode fibre 1002MC-LX-ZZ
type Description code
Ethernet / Fibre 1 Port 10/100BaseTX to 1 Port 100BaseFX Media Converter 1 Port (multimode fibre optic port, 4 km)
sL-2Es-2XX
1 Port 10/100BaseTX to 1 Port 100BaseFX Media Converter 1 Port (singlemode fibre optic port, 20 km)
SL-2ES-3XX
1 Port 10/100BaseTX to 1 Port 100BaseFX Media Converter 1 Port (singlemode fibre optic port, 60 km)
SL-2ES-3XX-L
serial / Ethernet / Fibre converters
serial / Ethernet / Fibre converters
Media converters
telephone Modem
sEr-485-FXc
102Mc
1002Mc
sL-2Es-XXX
Vt series order codes
Description code
DIN-Rail Mount Industrial Telephone Modem (supports baud rates up 56K) Vt-MoDEM-5ww
*Note: Complete with a RS232 modem cable (DB9) and Windows software.
10.8. Telephone Modem
Discount code L7
table code XX = ST or SC connectorsYY = 15,40 or 80 for Km fibre lengthsZZ = 10,40 or 80 for Single Mode fibre length
table code XX = ST or SC connectors
10.9. 10.10.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11.1.1.1. XXX11.1.1. XXX
Section Guide Overview Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
11. Protocol & Signal converterS
Section 11
11-485
Protocol & Signal converterS
11. Protocol & Signal converterS 11-48411.1. Protocol converters 11-48611.2. ethernet to Serial Server 11-49811.3. Modbus ethernet to Serial gateway 11-49911.4. rS 232 to rS 485/422 converter 11-50011.5. rS 485/422 isolated repeater 11-50111.6. Signal converters 11-502
11.6.1. Process Inputs 11-50211.6.1.1. Analog Converter & Switch 11-50211.6.1.2. Analog Converter / Isolator 11-50311.6.1.3. Slim Analog Converter / Isolator 11-50411.6.1.4. Loop Powered Analog Isolator 11-50511.6.1.5. Analog to Frequency Converter 11-505
11.6.2. Temperature Inputs 11-50611.6.2.1. Temperature Converter & Switch 11-50611.6.2.2. RTD to Analog Converter 11-50711.6.2.3. TC to Analog Converter 11-507
11.6.3. Frequency Inputs 11-50811.6.3.1. Frequency to Analog Converter 11-50811.6.3.2. Under / Over Speed Switch 11-509
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS
11
11.1. Protocol Converters
Data Station Plus – the complete Data Management Solution
Seamless integration of multi-vendor systems
• MultipleProtocolConverterallowscompletesystemintegration• IT-readydataloggingforprocesstrackingandimprovement• Remoteassetmanagementandcontrolviabuilt-inwebserver• ReducedowntimewithemailandSMSalarmcapability
now it’s easy to get all your devices on the same page.
Red Lion’s Data Station Plus is the single-device solution forprotocol conversion. The DSP bridges the communication gapbetweendisparateserial,Ethernetandfieldbusdevices—unlockinguntold information from PLCs, drives, motion controllers, etc.,orphaned by incompatiblecommunicationsstandards.Draganddrop registermapping allows aSiemensPLC to talk to anAllenBradleydriveinjustseconds.Withagrowinglistofover130serial,Ethernet andfieldbusdrivers, theDSPallowsyou tochoose thebest-in-class automation components, without worrying overwhether or not they’ll communicate with one another.
network your existing equipment to avoid risk
Getting legacy machines onto a common communications backbone used to be largely impossible, sometimesrequiringacompletereplacementoftheautomationcomponents.TheDataStationPlusallowsyouconvertyouroldPLC’sanddrive’sproprietaryprotocolintoamodernandopenstandard.Byunlockinginformationhiddenintheselegacydevices,yousavemoneywhileavoidingariskyupgradetoequipmentthatisotherwiseworkingperfectly.
oeMS—add ethernet and oPc connectivity to all of your machines.
AddaDataStationPlustoyourequipment,andyoucanofferyourcustomersout-of-boxconnectivitytotheirSCADAsystems,while providing yourself themeans to remotely support themachine. TheDSP’s ability to support fourEthernetprotocolssimultaneously,whileofferingOPCcompatibility,meansyoudon’thavetoworryabouthowthesystemwillbeintegratedattheuser’sfacility.Andthat’sjustthebeginning.The“portsharing”facilityallowstheDataStationPlustoactasaremoteserialporttoyourPC,meaningyoucanreprogramanyconnectedserialdevicefromvirtually anywhere in the world.
11-487
11.1. Protocol Converters
11
Data Station Plus Models
reduce costs using data management
Monitor the vital signs of your machines and processes
Data points logged from devices, machines and processes provide a performancebaselineforanalysis,andcanbeusedtotriggerPLCfunctions,alarmsornotificationswhenpointsstray fromnominalparameters.Thesevariablescanbeusedasreliablepredictorsof impendingmachinefailure,monitoringforpreventativemaintenance,aswellasgeneralperformancemonitoringofdistributedprocessesordiscreteproductionthroughput. Reliable data can be used to identify process vulnerabilities, abnormalconditionsorweartrending.Loggingcanbeusedforreal-timemonitoringofprocessactivities,producttraceabilityandqualitycontrolissues,TPM,downtime,OEE(overallequipment effectiveness), or be used to generate virtually unlimited data sets forstatistical analysis and control decisions.
Know more. Do More
One Data Station Plus allows a user to quickly set up monitoring of a number ofdisparatedevicesinacontrolapplication,collectperformancedata,displayit,storeitforevaluation,ortriggerPLCfunctions,eitherliveorremotely.
TheDataStationPlus’built-inmathcapabilityalsoallowsprobabilitycalculations topre-analyzehardpointdata toprovideonly relevant information.An integratedOPCserverallowseasySCADAconnectivityusingRedLion’sOPCWorx.
ThemultipleData,Alarm,EventandSecurityloggersinCrimson3providedatain“ITready”CSV(commaseparatedvalues)filesthatcanbeeasilyopenedwithapplicationssuchasMicrosoft®Excel.Nosoftwareplug-insarerequiredtoaccessyourapplicationdata.Andabuilt-inCompactFlash®cardslotprovidesunlimiteddatastorageaswellassecureandimmediateretrievaloftheDSP’sconfiguration.
Alltherequirementsforqualitytraceability,productiontrackingormaintenancearenowembeddedintooneplatform.Theabilitytomonitoryourprocesscanbesetupinjustminutes with the DSP’s connectivity and logging tools.
Data logging
alarms and events logging
Security logging
DSPle DSPSX DSPgt DSPZr
Protocol conversion
Data logging
Web server 320x240QuarterVGA 640x480FullVGA 1024x768XGA
email & SMS
Four models to choose from
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.1. Protocol Converters
11
reduce costs using data management
view and control your system remotely
With its built-in web server, the Data Station Plus allows you toremotelymonitorandcontrolyourprocesswiththeclickofamouse.Web-enabling your process facilitates remote real-time monitoring,operation,diagnosticsanddataacquisitionfromanynetworkedPC,aswellassmartphonesoranyweb-enabledtablet.Acompletegraphicspackage,with over 4000 images, can be used to accurately depictyour machine or process.TheDataStationPlus’canautomaticallysynchronize its logfilesviaFTPtoaremoteserver for longtermstorage.Logfilesmayalsoberetrieved manually or emailed on command.
Faster reaction. Save time. Save Money
TheDataStationPlus’messagingfacilitiescanbeusedtosendalarmsoreventsusinge-mailorSMStextmessagestoPCs,aswellasPDAsandmobilephones.Filescanbeattachedtoe-mailsoreportor logginginformationarrivedirectlytotheappropriatepersonnel,facilitatingfaster interventionormaintenancewhenproblemsoccur.
Protocol conversion. ethernet gateway. it-ready data logging. it’s all here.
TheDataStationPlusisconfiguredwithCrimson3configurationsoftware,whichisnotonlypowerfulandeasytouse–it’sfree.Thecombinationofprotocolconversion,webandFTPserversanddatalogging,withitslargelibraryofcommunicationdrivers,createsaseamlessmethodtoconnectallyourdevicestoasecureandeasilyaccessiblenetwork,eventhosestrandedbylegacytechnology.TheDataStationPlusissimplythemosteconomical,easiesttointegrate,datalogging,monitoringandcontrol system ever developed. The Data Station Plus’
11-489
11.1. Protocol Converters
11
the universal solution to monitoring, management and control
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.1. Protocol Converters
11
Port Forwarder Mitsubishi: Q Series tcP/iP Master
raw tcP/iP active Modbus: Device gateway
raw tcP/iP Passive Modbus: encapsulated Master
raw UDP/iP Modbus: tcP/iP Master
ac tech: Simple Servo UDP Modbus: tcP/iP Slave
acromag: tcP/iP Master omron: g9SP-Series via FinS
adenus: telnet Driver omron: Master via FinS
allen-Bradley: DF1 Master oPc: tcP/iP Master
allen-Bradley: DF1 Master via Pccc/eiP Panasonic - Matsushita: FP Series - MeWtocol
allen-Bradley: DF1 Slave Parker: acroloop tcP/iP Master
allen-Bradley: encapsulated DF1 Master Parker: compumotor 6K tcP/iP Master
allen-Bradley: native tag addressing Phoenix contact: nanolc tcP
Allen-Bradley: Native Tags via L5K file Plc Direct Koyo: eBc UDP/iP Master
alstom: alSPa tcP/iP Master via SrtP Plc Direct Koyo: ecoM UDP/iP Master
alstom: geM80 eSP tcP/iP Master Schneider: Plc via Modbus tcP/iP
Bacnet: 802.3 Master Schneider - telemecanique: tSX 57 tcP/iP Master
Bacnet: 802.3 Slave Siemens: S5 aS511 via tcP/iP version 1.04
Bacnet: UDP/iP Master Siemens: S5 aS511 via tcP/iP version 2.02
Bacnet: UDP/iP Slave Siemens: S7 300/400 tcP/iP Master
Banner: PresencePlUS Data Siemens: S7 cP243 via iSo tcP/iP Master
Banner: PresencePlUS image Siemens: ti 500 Series tcP/iP Master
Banner: vision Systems ivu Plus vision SnMP: SnMP agent
Beckhoff: ADS/AMS TCP toshiba: t2 Plc Master
Beta laserMike: laserSpeed UDP Unitronics: PcoM aScii tcP/iP Master
Beta laserMike: laserSpeed UDP Final length Mode Slave Unitronics: PcoM Binary tcP/iP Master
Bristol Babcock BSaP: UDP Yamaha: rcX Series tcP/iP Master
Bristol Babcock BSaP: UDP Slave Yaskawa: tcP/iP Master (legacy only)
cti: 2500/2572 caMP tcP/iP Master Yaskawa: tcP/iP Memobus Master
cti: nitP tcP/iP Master Yaskawa: tcP/iP MP2000iec
ethernet i/P: Slave adapter Yaskawa: tcP/iP Series 7
eZ automation: eZ tcP/iP Master Yaskawa: tcP/iP Universal SMc Master
Fatek: Plc Yokogawa: Fa-M3 Plc tcP/iP Master
galil: tcP/iP Driver
ge: tcP/iP Master via SrtP
Honeywell: S9000
KeB: Din66019ii tcP/iP Master
Maguire: Mlan tcP/iP
MicroMod: tcP/iP Master
Mitsubishi: a/Q/FX Series tcP/iP Master
Mitsubishi: a/Q/FX Series UDP/iP Master
Mitsubishi: FX2n encapsulated tcP/iP Master
Data Station Plus Driver communication list - ethernet
11-491
11.1. Protocol Converters
11
generic Program-thru emerson - control techniques: Quantum
PPP and Modem client eurotherm: BiSYncH aScii
PPP and Modem Server eZ automation: eZ Master
raw Serial Port Fatek: Plc
SMS via gSM Modem Festo: FPc, iPc, Fec, Series controller
virtual Serial Port Flowcom: Master
aBB: coMlinK Master galil: Serial Driver
ac tech: Simple Servo garmin: nMea-0183
adam: 4000 Series Modules ge: SnP Master
allen-Bradley: DF1 Master ge: SnP-X Master
allen-Bradley: DH485 Master giddings and lewis: c/e controller
allen-Bradley: native tag addressing Hardy instruments: Hardy link
allen-Bradley: Ultra 3000 HBM: aeD/PW/Fit
alpha gear: ternary Hectronic: controller
alstom: alSPa Master via SnP Hitachi: Hitachi H Series
alstom: geM80 eSP J/K Master Honeywell: iPc620
alstom: geM80 eSP J/K Slave icP DaS: Dcon Serial Master
alstom: geM80 eSP Program Port Master iDec: Micro 3 Series/onc
animatics: Smart Motor iFM: aSi Master via coDeSys SP
applied Motion: Scl iMo: g Series loader Port
B&r: Mininet Serial Driver iMo: K Series loader Port
Bacnet: MS/tP Master iMo: Plc-cnet
Bacnet: MS/tP Slave indramat: clc Master
Baldor: Mint Host intelligent actuator: robocylinder/e-con
Beta laserMike: laserSpeed intelligent actuator: XSel
Beta laserMike: laserSpeed Final length Mode Slave inUSa: Sci-tUrBo l
Bristol Babcock BSaP: BSaP Serial Slave ircon: Modline
Bristol Babcock BSaP: Serial Johnson controls: Metasys n2 Slave
caterpillar: Data link Monitor 1.0 Julabo: circulator Head
contrex: M(l)-trim/Ml-Drive KeB: Din66019ii Master
contrex: M-rotary/M-cut KeB: Din66019ii Slave
control techniques: Mentor ii Master Keltec: Power Supply
cruisair: temperature controller Keyence: Kv Series
ctc: 2000 Series Master King: KingBus aScii
cti: 25xx caMP Master Klockner Moeller: PS4-201
cti: nitP Serial Master Kollmorgan: ac Drives
Danfoss: vlt/Fc Series Krohne: Flowmeter iFc020D
Dri-air: aDc laetus: Barcode Scanners
Dupline: Mastergenerator via Modbus lenze: lecoM-a/B Master
eaton: elc Master lg-lS industrial Systems: Master-K via cnet
elmo: elmo Drives Maguire: Mlan
eMco: FP-93 Matsushita: FP Series
emerson: er3000 MicroMod: extended Modbus
emerson Process: FloBoss via roc Protocol MicroMod: Micro-Dci
Data Station Plus Driver communication list - Serial
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.1. Protocol Converters
11
Mitsubishi electric: a/Q/FX Series - MelSec Siemens: S7 via PPi version 1.02
Mitsubishi electric: FX Series Siemens: S7 via PPi version 2.00
Mitsubishi electric: MelSec 4 Slave Siemens: ti-500 Series version 1.03
Mitsubishi electric: MelServo Siemens: ti-500 Series version 2.00
Modbus: aScii Slave Siemens: USS Drives
Modbus: Device gateway SMa: Data Master
Modbus: rtU Monitor SMc: lc8
Modbus: rtU Slave SPi: tributary Station
Modbus: Universal Master Square D: SYMaX
Motrona: lecoM Master SSD Drives: 590 (old Style)
MP electronics: gti Series and Similar SSD Drives: 590+
MtS: DDa Master SSD Drives: 631
MtS: DDa Slave SSD Drives: 635/637
MtS: Modbus Master SSD Drives: 690+/650v
omron: g9SP-Series Stiebel eltron: WPMii
omron: Master via FinS toshiba: Series Plc
omron: Series c Plc toshiba: tosvert inverter
oriental Motor: Motor Drive Unitronics: Master
Pacific Scientific: 830 Master Unitronics: PcoM aScii Master
Panasonic - Matsushita: FP Series - FP MeWtocol-coM Unitronics: PcoM Binary Master
Panasonic - Matsushita: FP Series - MeWtocol-Binary Yamaha: rcX Series
Parker: acroloop Motion controller Yaskawa: ac Drives a1000
Parker: compumotor 6K Master Yaskawa: FSP Drive
Pason: WitS Yaskawa: legend/SMc 3010
Phoenix contact: nanolc Yaskawa: MP Series controller
Plc Direct Koyo: Directnet Yaskawa: nS600 indexer
Plc Direct Koyo: K Sequence Yaskawa: Series 7 inverters
PQ Systems: tern controller Yaskawa: SgDH
QuickSilver: Quicksilver Master Yaskawa: Universal SMc
red lion: Big Flexible Display Yet: Xtra Drive
red lion: little Flexible Display Yokogawa: Fa-M3 Plc Master
red lion: Plant Floor Marquee
red lion: rlc instrument
rexroth indramat: ecodrive
rexroth indramat: SiS
richards-Wilcox: intelligent Storage Systems
Schneider: Plc via Modbus
Schneider - telemecanique: Uni-telway Master
Schneider - telemecanique: Uni-telway Slave
SeW: MovilinK a Master
SeW: MovilinK B Master
Siemens: S5 via aS511 version 1.04
Siemens: S5 via aS511 version 2.02
Siemens: S7 via MPi adaptor
Data Station Plus Driver communication list - Serial
11-493
11.1. Protocol Converters Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
Data Station Plus le
• Convertsnumerousprotocolssimultaneously• ExtensiveBuilt-indriverlistallowseasydatamappingtoPLC,PC’sandSCADASystems• Two(2)RS232&one(1)RS485/422serialcommunicationports• 10/100Base-TEthernetportsupportsmultipleprotocolssimultaneously• USBPorttodownloadtheunit’sconfigurationfromaPC• CompactFlashSocketforprogrammingonly• Optionalcardaddsfieldbusconnectivityorextraserialports• Supportsuptonine(9)protocolssimultaneously(withexpansioncardinstalled)
order codes
accessories
Description code
DataStationwithmultipleprotocolconverter,Two(2)RS232&one(1)RS485/422serialcommunicationports,Ethernetandexpansionslot.
DSPle000
options
AdditionalRS232/485portoptioncard XcrS0000
Additional10/100Base-TEthernetportoptioncard Xcenet00
CANopen/CANBusportoptioncard Xccn0000
DeviceNetportoptioncard XcDn0000
Profibus-DPportoptioncard XcPBDP00
Description code
USBProgrammingCable(3m) cBlUSB00
CommunicationsCablestoSerial3rdPartyDevices(3m) cBlxxxxx*
DIN-RailRJ-45ConnectortoScrewTerminalAdapter DrrJ45t8
DIN-RailRJ-11/12ConnectortoScrewTerminalAdapter DrrJ11t6
1GbCompactFlashCard g3cF001g
* Contact Customer Service
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.1. Protocol Converters Stock Status:
Normally stocked /Not normally stocked
Discount Code L3
11
Data Station Plus SX
• Protocolconverterthatconvertsnumerousprotocolssimultaneously• In-builtDataLoggerallowsprocessdatatobeloggeddirectlytoCSVfiles• In-builtWebServerprovidesavirtualHMIwithSCADAfunctionality(QVGADisplay)• Webserverprovidesworld-wideaccesstodatalogsandvirtualHMI• ExtensiveBuilt-indriverlistallowseasydatamappingtoPLC,PC’sandSCADASystems• AlarmnotificationscanbesentviaemailorSMSmessages• 10/100Base-TEthernetportsupportsmultipleprotocolssimultaneously• Two(2)RS232&one(1)RS485/422serialcommunicationports• Optionalcardaddsfieldbusconnectivityorextraserialports• Supportsuptonine(9)protocolssimultaneously(withexpansioncardinstalled)
order codes
accessories
Description code
DataStationwithmultipleprotocolconverter,Two(2)RS232&one(1)RS485/422serialcommunicationports,Ethernetport.Addedfeaturessuchasdatalogger,webserverwithVirtualHMIuptoQVGA(320x240)andexpansionslot.0-50˚CoperatingTemp.
DSPSX000
DataStationwithmultipleprotocolconverter,Two(2)RS232&one(1)RS485/422serialcommunicationports,Ethernetport.Addedfeaturessuchasdatalogger,webserverwithVirtualHMIuptoQVGA(320x240)andexpansionslot.0-70˚CoperatingTemp.
DSPSX001
options
AdditionalRS232/485portoptioncard XcrS0000
Additional10/100Base-TEthernetportoptioncard Xcenet00
CANopen/CANBusportoptioncard Xccn0000
DeviceNetportoptioncard XcDn0000
Profibus-DPportoptioncard XcPBDP00
GSMModemoptioncard XcgSM000
Description code
USBProgrammingCable(3m) cBlUSB00
CommunicationsCablestoSerial3rdPartyDevices(3m) cBlxxxxx*
DIN-RailRJ-45ConnectortoScrewTerminalAdapter DrrJ45t8
DIN-RailRJ-11/12ConnectortoScrewTerminalAdapter DrrJ11t6
1GbCompactFlashCard g3cF001g
2GbCompactFlashCard g3cF002g
5dBPanelMountAntennawith5mCableforXCGSM000OptionCard ant5DB5M
7dBPanelMountAntennawith5mCableforXCGSM000OptionCard ant7DB5M
* Contact Customer Service
11-495
11.1. Protocol Converters Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
Data Station Plus gt
• Protocolconverterthatconvertsnumerousprotocolssimultaneously• In-builtDataLoggerallowsprocessdatatobeloggeddirectlytoCSVfiles• In-builtWebServerprovidesavirtualHMIwithSCADAfunctionality(VGADisplay)• Webserverprovidesworld-wideaccesstodatalogsandvirtualHMI• ExtensiveBuilt-indriverlistallowseasydatamappingtoPLC,PC’sandSCADASystems• AlarmnotificationscanbesentviaemailorSMSmessages• 10/100Base-TEthernetportsupportsmultipleprotocolssimultaneously• Two(2)RS232&one(1)RS485/422serialcommunicationports• Optionalcardaddsfieldbusconnectivityorextraserialports• Supportsuptonine(9)protocolssimultaneously(withexpansioncardinstalled)
order codes
accessories
Description code
DataStationwithmultipleprotocolconverter,Two(2)RS232&one(1)RS485/422serialcommunicationports,Ethernetport.Addedfeaturessuchasdatalogger,webserverwithVirtualHMIuptoVGA(640x480)andexpansionslot.0-50˚CoperatingTemp.
DSPgt000
DataStationwithmultipleprotocolconverter,Two(2)RS232&one(1)RS485/422serialcommunicationports,Ethernetport.Addedfeaturessuchasdatalogger,webserverwithVirtualHMIuptoVGA(640x480)andexpansionslot.0-70˚CoperatingTemp.
DSPgt001
options
AdditionalRS232/485portoptioncard XcrS0000
Additional10/100Base-TEthernetportoptioncard Xcenet00
CANopen/CANBusportoptioncard Xccn0000
DeviceNetportoptioncard XcDn0000
Profibus-DPportoptioncard XcBDP00
GSMModemoptioncard XcgSM000
Description code
USBProgrammingCable(3m) cBlUSB00
CommunicationsCablestoSerial3rdPartyDevices(3m) cBlxxxxx*
DIN-RailRJ-45ConnectortoScrewTerminalAdapter DrrJ45t8
DIN-RailRJ-11/12ConnectortoScrewTerminalAdapter DrrJ11t6
1GbCompactFlashCard g3cF001g
2GbCompactFlashCard g3cF002g
5dBPanelMountAntennawith5mCableforXCGSM000OptionCard ant5DB5M
7dBPanelMountAntennawith5mCableforXCGSM000OptionCard ant7DB5M
* Contact Customer Service
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.1. Protocol Converters Stock Status:
Normally stocked /Not normally stocked
Discount Code L3
11
enhanced Data Station Plus Zr
• ProtocolConversionFeatureConvertsNumerousProtocolsSimultaneously• Allatprocessingspeedssixtimesfasterthanpreviousversions• 250+CommunicationsDriversforCommunicatingDirectlywithPLCs,Drives,Etc.• SyncsDataLogstoFTPServersandMicrosoftSQLServer®• Built-InWebserverAllowsRemoteVieworControlFromAnyInternetConnectedPC(XGADisplay)• ProvidesEmailandSMSTextMessageAlerts• USBHostPorttoDownloadtheUnit’sConfigurationfromaPCorforDataTransferstoaPC• 10BASE-T/100BASE-TXEthernetConnectioncanconnecttoanUnlimitedNumberofDevicesviaTenProtocolsSimultaneously
order codes
accessories
Description code
DataStationwithmultipleprotocolconverter,Two(2)RS232&one(1)RS485/422serialcommunicationports,Ethernetport.Addedfeaturessuchasdatalogger,webserverwithVirtualHMIuptoXGA(1024×768)andexpansionslot.
DSPZr000
options
AdditionalRS232/485portoptioncard XcrS0000
Additional10/100Base-TEthernetportoptioncard Xcenet00
CANopen/CANBusportoptioncard Xccn0000
DeviceNetportoptioncard XcDn0000
Profibus-DPportoptioncard XcPBDP00
GSMModemoptioncard XcgSM000
Description code
USBProgrammingCable(3m) cBlUSB00
CommunicationsCablestoSerial3rdPartyDevices(3m) cBlxxxxx*
DIN-RailRJ-45ConnectortoScrewTerminalAdapter DrrJ45t8
DIN-RailRJ-11/12ConnectortoScrewTerminalAdapter DrrJ11t6
1GbCompactFlashCard g3cF001g
2GbCompactFlashCard g3cF002g
5dBPanelMountAntennawith5mCableforXCGSM000OptionCard ant5DB5M
7dBPanelMountAntennawith5mCableforXCGSM000OptionCard ant7DB5M
* Contact Customer Service
11-497
11.1. Protocol Converters
11
crimson 3.0 Programming Software
Protocol conversion in just 5 steps
ProgrammingsoftwarefortheDataStationPluswithmultipleprotocolsupportbuiltin.Asecondprotocolcanbechosentoacquiredata from theoriginaldriver.Oncecollected, theDataStationPluscanconvert thedata toadifferentprotocol so that it canbeintegratedwithvirtuallyanyPLC,PCorSCADAsystem.ThedatamayalsoberecordedinIT-friendlyCSVfileformatforlaterreview,usingthebuilt-indataloggingfacilities.
WiththeDataStationPlusprotocolconverter,youhavetheabilitytoexchangedatabetweenanyandallconnecteddevices.Withafewclicksofthemouse,youcanmapasetpointfromaPLCtoavariablespeeddrive,orprovideanAllenBradleyPLCprogramwithinformationastothestatusofaSiemensPLC.
Ethernet
Serial
AB PLC
ABBVSD
Siemens PLC
SCADA
Data Station Plus
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterSStock Status:normally stocked /Not normally stocked
11
Discount code l7
11.2.EthernettoSerialServer
eServ-11t/12t
• UptoTwoActiveSerialPorts• OneEthernetPort(Choose10/100BaseTXRJ-45orMultimodeFibrewithSTstyleconnector)• ConnectsRS-232,RS-422,orRS-485DevicestoyourLANorWAN• DIN-RailEnclosure• -34ºto80°COperatingTemperature• AutoDetecting10/100BaseTXEthernetPort• 10to58VDCInputPowerRange• PairedModeorSerialTunnelling-SerialDevicesExchangeDatausingyourEthernetNetwork• IPApplicationsCommunicateDirectlywithSerialDevices• VirtualCOMPort-PC’sCommunicatewithSerialDevicesasiftheywereConnectedtoaLocalCOMPort• SimpleConfigurationthroughtheBuilt-inWebServerorWindowsConfigurationSoftware• HeartbeatConnection-DetectsCommunicationFailuresandAutomaticallyReconnects• VCOMdriversforWindows2000,2003Server,XP,andVista
order codes
Description code
EthernettoSerialServerwith(1)Serialport(DB9orTBconnector);(1)Ethernetport(RJ-45)
ESERV-11T
EthernettoSerialServerwith(1)Serialport(DB9orTBconnector);(1)EthernetMultimodeFibreport(STstyleconnector)
ESERV-11T-ST
EthernettoSerialServerwith(2)Serialports(TBconnectors);(1)Ethernetport(RJ-45)
ESERV-12T
EthernettoSerialServerwith(2)Serialports(TBconnectors);(1)EthernetMultimodeFibreport(STstyleconnector)
ESERV-12T-ST
eServ-12teServ-11t
11-499
Stock Status:Normally stocked /Not normally stocked
11
Discount code l7
11.3.ModbusEthernettoSerialGateway
eServ-M12t
• UptoTwoActiveSerialPortsviaTBSerialConnectors• OneEthernetPort(Choose10/100BaseTXRJ-45orMultimodeFibrewithSTstyleconnector)• ConnectsModbusRS-232,RS-422,orRS-485SerialDevicestoyourModbusTCPLANorWAN• -34ºto80°COperatingTemperature• AutoDetecting10/100BaseTXEthernetPort• 10to58VDCInputPowerRange• RemovableTerminalBlocksSimplifyPowerandDataCommunications• ModbusMessagingPriorityControl• ViewMessagingStatusinRealTime• SimpleConfigurationthroughtheBuilt-inWebServerorWindowsConfigurationSoftware• HeartbeatConnection-DetectsCommunicationFailuresandAutomaticallyReconnects• VCOMdriversforWindows2000,2003Server,XP,andVista
order codes
Description code
ModbusEthernettoSerialGatewaywith(2)Serialports(TBconnectors);(1)Ethernetport(RJ-45)
eServ-M12t
ModbusEthernettoSerialGatewaywith(2)Serialports(TBconnectors);(1)EthernetMultimodeFibreport(STstyleconnector)
ESERV-M12T-ST
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterSStock Status:normally stocked /Not normally stocked
Discount code l3
11
11.4.RS232toRS485/422Converter
icM5
• ThreeWayIsolationprotectsserialequipmentfromgroundloops(1000VDC)• ModularRJjackorscrewterminalsforRS485connection• 9-pinD-SUBforRS232Connection• SelectableDTE&DCEOperation-WorkswithanyRS232cable• SelectableBaudRatesfrom9600to115200• LEDIndicationforRXD,TXD,andPower• HalfDuplex(RS485)andFullDuplex(RS422)• 9to26VDCPower
TheICM5SerialConverterModuleprovidesthecapabilityofinterfacingequipmentwithRS-485serialcommunicationstoequipmentwithRS-232communicationswhileprovidingthreewayisolation.DataformatoftheRS-232andRS-485equipmentmustbethesame.
order codes
Description code
RS232toRS485/422IsolatedConverter icM50000
11-501
Stock Status:Normally stocked /Not normally stocked
11
Discount code l7
11.5.RS485/422IsolatedRepeater
Ser-485-ir
• SupportsDataRatesupto115.2Kbps• ExtendsSignal4,000feet(1200Meters)• Wide-40to80°CTemperatureRange• 10to48VDCInputPowerRange• 2000V3-WayOpticalIsolation• ULClass1DIV2Listed• Built-in,SwitchableTermination&Bias
TheSER-485-IRisourindustrialRS-422/485isolatedrepeater.Powerfulopticalisolationonbothdataportsprotectsyourequipmentanddatafromdamaginggroundloopsandsurges.Additionalisolationonthepowersupplycircuitsaddsathirddegreeofprotection.
order codes
Description code
RS485/422IsolatedRepeater Ser-485-ir
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterSStock Status:normally stocked /Not normally stocked
Discount code l3
11
11.6. Signal Converters11.6.1. Process Inputs
Universal analog converter & Switch - iaMS Series
• UniversalPowerSupply,21.6to253VAC/19.2to300VDC• 3-wayIsolation(Power/Signal/Output)• ChooseSetpointsand/orAnalogOutputModels• Programming/DisplayModule(PGMMOD)
The IAMS is a universal signal conditioner with unmatched capability that provides users the ultimate in flexibility. As a signalconditioner, the unit provides complete isolation and conversion capability to satisfy almost any application. TheUniversal InputacceptsProcess,DCCurrent,DCVoltage,Thermocouples,RTDs,Potentiometers,andLinearResistancesignalsallowingthemoduletobeconnectedtomostcommonsensors.ThesetpointmodelallowsdualsetpointcontrolcapabilitythroughdualFormArelays.Theanalogmodelprovidesaretransmittedanalogsignal.Athirdmodelprovidesbothanalogandcontrolcapability.Thepowersupplyisalsouniversal,accepting21.6to253VAC/19.2to300VDCasitspowersource.Addtheoptionalprogrammingmoduleandtheunitiseasilyprogrammedthroughmenustyleprogramming.Themodulecanalsobeusedtoprovideadisplayoftheprocessvariablewhenit isnotbeingusedforprogramming.Whentheprogrammingmoduleisnotbeingusedforprogramming,itcanindicatetheinputparameters,justlikeapanelmeter.
current input: Programmable ranges: 0to20and4to20mADCvoltage input: Programmable ranges: 0to1,0.2to1,0to5,1to5,1to10,and2to10VDCthermocouple inputs: B,E,J,K,L,N,R,S,T,U,W3,W5,andLRrtD, linear resistance, Potentiometer inputs: Pt10,Pt20,Pt50,Pt100,Pt200,Pt250,Pt300,Pt400,Pt500,Pt1000, Ni50,Ni100,Ni120,andNi1000
order codes
Description code
Universal Signal Conditioner with Analog Output iaMS0001
Universal Signal Conditioner with Dual Relay Outputs iaMS0010
Universal Signal Conditioner with Analog Output & Dual Relay Outputs iaMS0011
ProgrammingDisplayModule PgMMoD00
11.6.1.1. Analog Converter & Switch
PgMMoD00
11-503
11.6. Signal Converters Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
11.6.1. Process Inputs
Universal analog converter / isolator - iaMa Series
• Economicalbutpowerful• 3-WayIsolation• SwitchSelectableInputs&Outputs• 100DifferentInputandOutputCombinations• 11to36VDCPowered
TheIAMAisauniversalsignalconditionerthatcanisolateandconvertover100combinationsofanalogsignalranges.TheIAMA3535convertsandtransmitssignals linearlyproportionaltothe input,whiletheIAMA6262transmitsthescaledsquarerootofthe inputsignal.ThisallowstheIAMA6262toprovideasignalthatislineartoflowrateinapplicationsutilizingadifferentialpressuretransducer.TheIAMAmodulesfeatureopticallyisolatedInput/OutputsignalcircuitsandtransformerisolatedPowertoInput,PowertoOutputcircuits.DIPswitchrangeselectioneliminatestheneedtoorderandstockdifferentmodulesforeachinputandoutputsignalrange,andallowsquickandconvenientsetupforover100standardsignalconversions.
order codes
input & output ranges
Description code
UniversalSignalConditioningModule/Isolator iaMa3535
SquareRootUniversalSignalConditioningModule IAMA6262
11.6.1.2. Analog Converter / Isolator
input voltages input currents output voltages output currents
0-20mV 0–1mA 0–5V 4–20mA
0–50mV 0–2mA 0–10V 0–20mA
0–100mV 0–5mA
0–200mV 0–10mA
0–500mV 4–20mA
0–1V 0–20mA
0–2V 0–50mA
1–5V 0–100mA
0–5V
0–10V
0–20V
0–50V
0–100V
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.6. Signal Converters Stock Status:
Normally stocked /Not normally stocked
Discount Code L3
11
11.6.1.3. Slim Analog Converter / Isolator11.6.1. Process Inputs
Slimline analog converter / isolator - iaMa Series
• 3-wayIsolationofAnalogSignals• UniversalConversionModule-InputsandOutputsSelectedViaDipSwitchSettings• Over35InputandOutputAnalogConversionCombinations• UltraSlimDesign–Only6.2mmWide• 19to30VDCPower
TheIAMAcanisolateandconvertover35combinationsofanalogsignalranges.TheIAMAconvertsandtransmitssignalslinearlyproportionaltotheinput.DIPswitchrangeselectioneliminatestheneedtoorderandstockdifferentmodulesforeachinputandoutputsignalrange,andallowsquickandconvenientsetupforover35standardsignalconversions.Inadditiontotheconversioncapabilities,theIAMAmodulesfeatureopticallyisolatedInput/OutputsignalcircuitsandisolatedPowertoInput,PowertoOutputcircuits.
input & output ranges
order codes
Description code
SlimlineSignalConditioningModule/Isolator iaMa0006
input voltages input currents output voltages output currents
0–10V 0–20mA 0–10V 0–20mA
2–10V 4–20mA 2–10V 4–20mA
0–5V 0–5V
1–5V 1–5V
11-505
11.6. Signal Converters Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
11.6.1. Process Inputs
loop Powered analog isolator - aiMi0202 Series
analog to Frequency converter - aFcM Series
• 0(4)to20mALoopPoweredIsolator• ProvidesInput/OutputIsolation
TheAIMI0202passivelooppoweredisolatorisusedfortheelectricalisolationandprocessingofanalog0(4)to20mAstandardcurrentsignals.TheAIMI0202provideselectricalisolationbetweenthecontrolelectronicsandprocessI/O.Inaddition.Inputandoutputcircuitdonotrequireseparateauxiliarypower.TheAIMI0202obtainspowerfromtheinputsignal.
• Voltage/CurrenttoFrequencyConverter• 3-wayIsolationofInput/OutputSignals• UniversalConversionModule-InputsandOutputsSelectedviaDIPSwitchSettings• UltraSlimDesign–Only6.2mmWide• 19to30VDCPower
The configurable analog to frequency converter is used to convert analog standard signals to frequency signals or pulse widthmodulated(PWM)signals.Inputsignalrangesare0-20mA,4-20mA,0-10mA,2-10mA,0-10V,2-10V,0-5V,or1-5V.TheDIPswitchesareaccessibleonthesideofthehousingandallowthefollowingparameterstobeconfigured:
• Input signal• Output values• Outputtype(frequencyorPWM)• Filtertype(forsmoothinginterferencesontheinputsignal)• Inputover/underrangefaultdetection
order codes
order codes
Description code
SlimlineSignalConditioningModule/Isolator AFCM0000
Description input output code
Loop Powered Signal Isolator 0(4)-20mA 0(4)-20mA aiMi0202
11.6.1.4. Loop Powered Analog Isolator11.6.1.5. Analog to Frequency Converter
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.6. Signal Converters Stock Status:
Normally stocked /Not normally stocked
Discount Code L3
11
11.6.2.1. Temperature Converter & Switch11.6.2. Temperature Inputs
Universal temperature converter & Switch - iaMS Series
• 3-wayIsolationOfAnalogSignals• UniversalPowerSupply,21.6to253VAC/19.2to300VDC• 3-wayIsolation(Power/Signal/Output)• ChooseSetpointsand/orAnalogOutputModels• Programming/DisplayModule(PGMMOD)
TheIAMSisauniversalsignalconditionerwithunmatchedcapabilitythatprovidesuserstheultimateinflexibility.Asasignalconditioner,theunitprovidescompleteisolationandconversioncapabilitytosatisfyalmostanyapplication.TheUniversalInputacceptsProcess,DCCurrent,DCVoltage,Thermocouples,RTDs,Potentiometers,andLinearResistancesignalsallowingthemoduletobeconnectedtomostcommonsensors.ThesetpointmodelallowsdualsetpointcontrolcapabilitythroughdualFormArelays.Theanalogmodelprovidesaretransmittedanalogsignal.Athirdmodelprovidesbothanalogandcontrolcapability.Thepowersupplyisalsouniversal,accepting 21.6 to 253 VAC/ 19.2 to 300 VDC as its power source. Add the optional programmingmodule and the unit is easilyprogrammedthroughmenustyleprogramming.Themodulecanalsobeusedtoprovideadisplayoftheprocessvariablewhenitisnotbeingusedforprogramming.Whentheprogrammingmoduleisnotbeingusedforprogramming,itcanindicatetheinputparameters,justlikeapanelmeter.
current input: ProgrammableRanges:0to20and4to20mADCvoltage input: ProgrammableRanges:0to1,0.2to1,0to5,1to5,1to10,and2to10VDCthermocouple inputs: B,E,J,K,L,N,R,S,T,U,W3,W5,andLRrtD, linear resistance, Potentiometer inputs: Pt10,Pt20,Pt50,Pt100,Pt200,Pt250,Pt300,Pt400,Pt500,Pt1000, Ni50,Ni100,Ni120,andNi100
order codes
Description code
Universal Signal Conditioner with Analog Output iaMS0001
Universal Signal Conditioner with Dual Relay Outputs iaMS0010
Universal Signal Conditioner with Analog Output & Dual Relay Outputs iaMS0011
ProgrammingDisplayModule PgMMoD00
PgMMoD00
11-507
11.6. Signal Converters Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
11.6.2. Temperature Inputs
rtD to analog converter - irMa Series
thermocouple to analog converter - itMa Series
• RTDInputModule• UserProgrammableInput• MultipleAnalogOutputs(0-20mA,4-20mA,0-10VDC)• ElectricalIsolation• 9to32VDCPowered
TheIRMAacceptsanRTDorresistanceinputandconvertsitintoavoltageorcurrentoutput.Theoutputislinearlyproportionaltothetemperatureorresistanceinput.Thisoutputisidealforinterfacingtoindicators,chartrecorders,controllers,orotherinstrumentationequipment.
• ThermocoupleInputModule• UserProgrammableInput• MultipleAnalogOutputs(0-20mA,4-20mA,0-10VDC)• ElectricalIsolation• 9to32VDCPowered
TheITMAacceptsathermocoupleormillivoltinputandconvertsitintoavoltageorcurrentoutput.Thevoltageorcurrentoutputislinearlyproportionaltothetemperatureormillivoltinput.Thisoutputisidealforinterfacingtoindicators,chartrecorders,controllers,or other instrumentation equipment.
order codes
order codes
Description code
Thermocouple to Analog Converter / Isolator itMa3035
Description code
RTD to Analog Converter / Isolator irMa3035
11.6.2.2. RTD to Analog Converter 11.6.2.3. TC to Analog Converter
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
11. Protocol & Signal converterS11.6. Signal Converters Stock Status:
Normally stocked /Not normally stocked
Discount Code L3
11
11.6.3.1. Frequency to Analog Converter11.6.3. Frequency Inputs
Frequency to analog converter - iFMa Series
• UserSettableFullScaleFrequencyfrom1Hzto25KHz• FourOutputOperatingRanges(0to5V,0to10V,0to20mA,and4to20mA)• ProgrammableInputCircuitAcceptsOutputsfromaVarietyofSensors• 85to250VACand9to32VDCPoweredVersionsAvailable• LowFrequencyCut-outandOverrangeIndication• 3-wayElectricalIsolation(Power/Input/Output)
TheModelIFMAacceptsafrequencyinput,andoutputsananalogvoltageorcurrentinproportiontotheinputfrequency,with0.1%accuracy.Thefullscaleinputfrequencycanbesettoanyvaluefrom1Hzto25KHz.
order codes
Description Supply voltage code
Pulse Rate Frequency to Analog Converter 85-250VAC iFMa0065
9-32VDC iFMa0035
11-509
11.6. Signal Converters Stock Status:Normally stocked /Not normally stocked
Discount Code L3
11
11.6.3. Frequency Inputs
Under / over Speed Switch - iFMr Series
• UserSettableTripFrequency,from0.1Hzto25kHz• Over-speed,Under-speed,andZero-speedDetection• RelayLatching,AlarmOverride,andAlarmResetFunctions• HysteresisandOffsetFunctionsAvailable• 85to250VACand9to32VDCVersionsAvailable
TheModelIFMRacceptsafrequencyinput,andcontrolsasinglerelay(SPDT)basedonthevalueoftheinputfrequency.TheTripfrequencycanbesettoanyvaluefrom0.1Hzto25KHz.TheIFMRcanbesettotriponoverspeed,orunderspeed(includingzerospeed).
order codes
Description Supply voltage code
Underspeed / Overspeed Switch 85-250VAC iFMr0066
9-32VDC iFMr0036
11.6.3.2. Under / Over Speed Switch
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12.1.1.1. XXX12.1.1. XXX
Section Guide Overview Stock Status:Normally stocked /Not normally stocked
Discount Code L3
12
12. Pilot Devices & RaDio contRol
section 12
12-511
Pilot Devices & RaDio contRol
12. Pilot Devices & RaDio contRol 12-51012.1. Pushbuttons 12-512
12.1.1. Standard Range 12-51212.1.2. Heavy Duty Range 12-51412.1.3. IP69K Range 12-516
12.2. Pilot lights 12-51812.2.1. Standard Range 12-51812.2.2. Heavy Duty Range 12-51912.2.3. IP69K Range 12-520
12.3. emergency stop Pushbuttons 12-52112.3.1. Standard Range 12-52112.3.2. Heavy Duty Range 12-52212.3.3. IP69K Range 12-522
12.4. selector switches (2 & 3 Positions) 12-52312.4.1. Standard Range 12-52312.4.2. Heavy Duty Range 12-52512.4.3. IP69K Range 12-526
12.5. selector switches (2 to 12 Pos.) 12-52712.5.1. Heavy Duty Range 12-52712.5.2. IP69K Range 12-527
12.6. Key-operated selector switches 12-52812.6.1. Standard Range 12-52812.6.2. Heavy Duty Range 12-529
12.7. toggle switches 12-53012.7.1. Standard Range 12-53012.7.2. Heavy Duty Range 12-530
12.8. Buzzers 12-53112.9. Potentiometer Drive 12-53112.10. assembled stations 12-532
12.10.1. Enclosed Pushbutton Stations 12-53212.10.2. Blank Enclosures 12-532
12.11. accessories 12-53312.11.1. Standard Range 12-53312.11.2. Heavy Duty Range 12-53612.11.3. IP69K Range 12-537
12.12. Joystick controllers 12-53812.13. Plastic & Metal enclosures 12-54012.14. Radio Wireless control 12-542
12.14.1. Overview 12-54212.14.2. Products 12-54312.14.3. Industry Solutions 12-546
12.14.3.1. Radio Crane 12-54612.14.3.2. Radio Safe 12-54812.14.3.3. Radio Green 12-55012.14.3.4. Radio Lift 12-55212.14.3.5. Radio Farm 12-55412.14.3.6. Radio Build 12-556
12.14.3.7. Radio Motion 12-55812.14.3.8. Radio Drive 12-560
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRolstock status:normally stocked /Not normally stocked
12
Discount code l10
12.1.1. Standard Range12.1. Pushbuttons
non-illuminated Pushbuttons – Plastic Body Metal Front Ring
order codes - supplied complete with Flush Pushbutton operator, Holder & contact Block
order codes - Momentary Pushbutton operator with Flush insert
order codes - Momentary Pushbutton operator with extended insert
order codes - Momentary Double Pushbutton operator
order codes - Maintained Pushbutton operator with insert Pack *
order codes - Momentary Mushroom operator
Description code
Green flush insert and 1 NO contact MP160G-10
Red flush insert and 1 NC contact MP160R-01
Red extended insert and 1 NO contact MP360R-01
Description code
Green MP130G
Red MP130R
Yellow MP130Y
Blue MP130L
White MP130W
Black MP130B
Description code
Green MP330G
Red MP330R
Yellow MP330Y
Blue MP330L
White MP330W
Black MP330B
Description code
Upper lower text
Green Flush Red Flush I/O MPD211B
Green Flush Red Extended I/O MPD1311B
Green Flush Red Extended Start/Stop MPD1511B
Description code
Flush insert MP230M
Raised insert MP430M
*Supplied with pack of 6 inserts (Red, Green, Yellow, Blue, White, Clear)
Description code
Red 40mm MPM110R
Yellow 40mm MPM110Y
Black 40mm MPM110B
complete Momentary Pushbutton operator
Front elements (1)
McBH-10
MP130G
MP330R
MPD211B
MPM110R
1. Front element2. Rear element
MP130Y 1
2
12-513
12.1. Pushbuttons Stock Status:Normally stocked /Not normally stocked
12
Discount code l10
12.1.1. Standard Range
illuminated Pushbuttons – Plastic Body Metal Front Ring
order codes - Momentary Pushbutton operator with coloured lens insert Pack*
order codes - Maintained Pushbutton operator with coloured lens insert Pack*
order codes - complete contact Block & Holder assembly
order codes - complete contact Block & Holder assembly
order codes - Momentary Double Pushbutton operator with coloured lens
order codes - Momentary Mushroom operator
Description code
Full voltage lamp block 6-240V AC/DC for Ba9s filament or LED lamp, max 2W McBH-001
Diode resistor lamp block 240V AC for Ba9s 130V filament bulb, max 2W McBH-003
Description code
1 N/O McBH-10
1 N/C McBH-01
2 N/O McBH-20
1 N/O & 1 N/C McBH-11
2 N/C McBH-02
additional contact blocks
1 N/O McB10
1 N/C McB01
Description code
Upper lower text
Green Flush Red Flush I/O MPD211C
Green Flush Red Extended I/O MPD1311C
Green Flush Red Extended Start/Stop MPD1511C
Description code
Flush insert MP131M
Raised insert MP331M
*Supplied with pack of 6 inserts (Red, Green, Yellow, Blue, White, Clear)
Description code
Flush insert MP231M
Raised insert MP431M
*Supplied with pack of 6 inserts (Red, Green, Yellow, Blue, White, Clear)
Description code
Red 40mm MPM111R
Yellow 40mm MPM111Y
Front elements (1)
Rear elements (2)
Rear elements (2)
MP131M
MP331M
MPD211c
MPM111R
McBH-20
MP331M1
2
1. Front element2. Rear element
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.1. Pushbuttons Stock Status:
Normally stocked /Not normally stocked
12
Discount code c5
12.1.2. Heavy Duty Range
non-illuminated Pushbuttons – Metal Body Metal Front Ring
order codes - Momentary Pushbutton operator
order codes - Maintained Pushbutton operator
order codes - Momentary Mushroom operator
Description code
Green eDt Gn
Red eDt Rt
Yellow eDt GB
Blue eDt Bl
White eDt Ws
Black EDT SW
Description code
Green EDTR GN
Red EDTR RT
Yellow EDTR GB
Blue EDTR BL
White EDTR WS
Black EDTR SW
Description code
Green 55mm EDP55 GN
Red 55mm EDP55 RT
Yellow 55mm EDP55 GB
Blue 55mm EDP55 BL
White 55mm EDP55 WS
Black 55mm EDP55 SW
* Other sizes available upon request.
Front elements (1)
order codes - contact Block
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
Rear elements (2)
eF03.1
1. Front element2. Rear element
eDt1
2
eDt Rt
12-515
12.1. Pushbuttons Stock Status:Normally stocked /Not normally stocked
12
Discount code c5
12.1.2. Heavy Duty Range
order codes - Maintained Pushbutton operator
Description code
Green eDl Gn
Red eDl Rt
Yellow eDl GB
Blue eDl Bl
White eDl Ws
Description code
Green EDLR GN
Red EDLR RT
Yellow EDLR GB
Blue EDLR BL
White EDLR WS
Black EDLR SW
illuminated Pushbuttons – Glass Body Metal Front Ring
order codes - Momentary Pushbutton operator
order codes - complete contact Block / lamp Block
order codes - Multi-leD’s White with Ba9s socket
Description code
Light terminal block 24V AC/DC for Ba9s filament or LED lamp ele
Light terminal block primary 115-230VAC, secondary 24V for Ba9s filament or LED lamp ele 230
Description code
LED lamp 24V AC/DC for Ba9s le24/9 Ws
LED lamp 230VAC for Ba9s le230/9 Ws
Front elements (1)
Rear elements (2)
lamp elements (3)
ele
le24/9 Ws
eDl1
2
3
1. Front element2. Rear element3. lamp (not shown in drawing)
eDl GB
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.1. Pushbuttons Stock Status:
Normally stocked /Not normally stocked
12
12.1.3. IP69K Range
non-illuminated Pushbuttons
order codes - complete iP69K Momentary Pushbutton operator & Holder assembly
order codes - complete iP69K Mushroom Momentary Pushbutton operator & Holder assembly
Description code
Blue nDt Bl
Yellow nDt GB
Green nDt Gn
Grey nDt GR
Red nDt Rt
Black nDt sW
White nDt Ws
Description code
Blue nDP 50Bl
Yellow nDP 50GB
Green nDP 50Gn
Black nDP 50sW
White nDP 50Ws
Front elements (1)
order codes - contact Block
Description code
1 N/C eF 10.1
1 N/O eF 03.1
2 N/C eF 220.1
2 N/O eF 033.1
1 N/C & 1 N/O eF 103.1
1 N/C & 1 N/O Overlapping eF 301.1
1 N/C & 1 N/O Simultaneous eF 303.1
1 N/C & 1 N/O Simultaneous with Safety Spring eF 303s.1
Rear elements (2)
eF03.1
1. Front element2. Rear element
nDt1
2
Discount code c5
nDt Gn
nDt Rt
nDP 50Gn
12-517
12.1. Pushbuttons Stock Status:Normally stocked /Not normally stocked
12
12.1.3. IP69K Range
Description code
Blue nDl Bl
Yellow nDl GB
Green nDl Gn
Red nDl Rt
White nDl Ws
order codes - contact Block
Description code
1 N/C eF 10.1
1 N/O eF 03.1
2 N/C eF 220.1
2 N/O eF 033.1
1 N/C & 1 N/O eF 103.1
1 N/C & 1 N/O Overlapping eF 301.1
1 N/C & 1 N/O Simultaneous eF 303.1
1 N/C & 1 N/O Simultaneous with Safety Spring eF 303s.1
Rear elements (3)
illuminated Pushbuttons
order codes - complete iP69K Momentary Pushbutton operator & Holder assembly
order codes - light terminal Blocks with integrated Multi-leD for illuminated Push Buttons nDl
voltage colour code
24V AC/DC Red elDe.n Rt 24
Green elDe.n Gn 24
Yellow elDe.n GB 24
Blue elDe.n Bl 24
White ELDE.N WS 24
115 – 230V AC Red ELDE.N RT 230
Green ELDE.N GN 230
Yellow ELDE.N GB 230
Blue ELDE.N BL 230
White ELDE.N WS 230
Front elements (1)
Rear elements (2)
Discount code c5
elDe.n Gn 24
nDl
eF 10.1 & eF 03.1
1
23
1. Front element2. Rear element3. contact Blocks
nDl Rt
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRolstock status:normally stocked /Not normally stocked
12
Discount code l10
12.2.1. Standard Range12.2. Pilot Lights
order codes - Pilot light Head
order codes - Rated voltage 230 - 240v ac
Description code
Red insert Ml1100R
Green insert Ml1100G
Yellow insert ML1100Y
Blue insert ML1100L
White insert Ml1100W
Clear insert ML1100C
Description code
Red MLBL07R
Green MLBL07G
Yellow MLBL07Y
Blue MLBL07L
White MLBL07W
Rear element holder McBH00
Front elements (1)
order codes - Holder
order codes - Rated voltage 24v ac/Dc
Description code
Rear element holder McBH00
Description code
Red MLBL01R
Green MlBl01G
Yellow MlBl01Y
Blue MlBl01l
White MlBl01W
Rear element holder McBH00
Rear elements (2)
Rear elements (3) - integrated leD lamp Blocks
Ml1100R
McBH00
MlBl01R
1. Front element2. Rear element3. lamp (not shown in drawing)
Ml1100R 1
2
3
12-519
12.2. Pilot Lights Stock Status:Normally stocked /Not normally stocked
12
eMl ..
Discount code c5
12.2.2. Heavy Duty Range
Description code
Red eMl Rt
Green eMl Gn
Yellow eMl GB
Blue eMl Bl
White eMl Ws
order codes - Pilot light Head
Front elements (1)
order codes - complete contact Block / lamp Block & Holder assembly
order codes - Multi-leD’s White with Ba9s socket
Description code
Light terminal block 24V AC/DC for Ba9s filament or LED lamp ele
Light terminal block primary 115-230VAC, secondary 24V for Ba9s filament or LED lamp ele 230
Description code
LED lamp 24V AC/DC for Ba9s le24/9 Ws
Rear elements (2)
Rear elements (3)
ele
le24/9 Ws
1. Front element2. Rear element3. lamp (not shown in drawing)
eMl1
2
3
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.2. Pilot Lights Stock Status:
Normally stocked /Not normally stocked
12
Discount code c5
12.2.3. IP69K Range
order codes - complete Pilot leD light Head & Holder assembly
Description code
Red nMl Rt
Green nMl Gn
Yellow nMl GB
Blue nMl Bl
White nMl Ws
Description code
Red nMeF Rt
Green nMeF Gn
Yellow nMeF GB
Blue nMeF Bl
White nMeF Ws
Front elements (1)
standard leD type
super Bright leD typeFront elements (1)
order codes - complete Pilot super Bright leD light Head & Holder assembly
order codes - lamp Blocks
order codes - lamp Blocks
Rear elements (2)
Rear elements (2)
Description voltage code
Light Terminal Block 24V AC/DC ele
115 – 230V AC ele 230
48V AC/DC ELE 48
Description voltage code
Light Terminal Block 24V AC/DC ele
115 – 230V AC ele 230
48V AC/DC ELE 48
ele
1. Front element2. Rear element note: lamp (not shown in drawing)
nMeF1
2
nMl GB
order codes - Multi-leD’s White with Ba9s socket
Description code
LED lamp 24V AC/DC for Ba9s le24/9 Ws
Rear elements (3)
ele
le24/9 Ws
1. Front element2. Rear element3. lamp (not shown in drawing)
nMl1
2
3
12-521
Stock Status:Normally stocked /Not normally stocked
12
Discount code l10
12.3. Emergency Stop Pushbuttons12.3.1. Standard Range
order codes - 40mm emergency stop operator
order codes - 60mm emergency stop operator
Description code
Non illuminated red Push on / Twist release MPMt310R
Non illuminated black Push on / Twist release MPMT310B
Non illuminated red Push on / Pull to release MPMP310R
Illuminated red Push on / Twist to release MPMT311R
Description code
Non illuminated red Push on / Twist release MPMT410R
Non illuminated red Push on / Pull to release MPMP410R
Illuminated red Push on / Twist to release MPMT411R
Description code
Non illuminated 40mm with 2 N/C contacts MPMt320R-02
Non illuminated 40mm with 1 N/O and 1 N/C contact MPMT320R-11
Front elements (1)
order codes
complete Push on / twist to Release emergency stop Red operators(suppled complete with holder and contact block)
order codes - complete contact Block & Holder assembly
Rear elements (2)
Description code
1 N/C McBH-01
1 N/O & 1 N/C McBH-11
2 N/C McBH-02
1 N/C & full voltage lamp block MCBH-011
additional contact blocks
1 N/O McB10
1 N/C McB01
1. Front element2. Rear element
1
2
MPMt310R
McBH-02
MPMt310R
MPMP310R
MPMt311R
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.3. Emergency Stop Pushbuttons Stock Status:
Normally stocked /Not normally stocked
12
12.3.2. Heavy Duty Range12.3.3. IP69K Range
order codes - 40mm emergency stop operator & Holder assembly
order codes - 50mm emergency stop operator & Holder assembly
order codes - 50mm emergency stop operator & Holder assembly
Description code
Non Illuminated Red, Push on / Twist & Pull Release eDRR 40 Rt
Description code
Non Illuminated Red, Push on / Twist & Pull Release eDRR 50 Rt
Description code
1 N/O & 1 N/C eF 303.1
2 N/C eF 220.1
Description code
2 N/C eF 220.1
Description code
E-Stop Enclosure Plastic MBK 311/GB
E-Stop Enclosure Metal MBG 311/GB
E-Stop Label Stainless Steel, Yellow with Lettering nDP-70/emergency-stop
Description code
Emergency stop label (70mm) with Emergency Stop Text nDP-70/emergency-stop
Front elements (1)
Front elements (1)
order codes - contact Block
order codes - complete contact Block
accessories
accessories for emergency stop operators
Rear elements (3)
Rear elements (3)
Description code
Non illuminated red Push on / Twist & pull to release nDRR 50Rt
* Required by each operator to secure operator & contact blocks
Heavy Duty Range
iP69K Range
order codes - secure spring element
order codes - secure spring element
Description code
Estop spring element required by each operator to secure operator & contact blocks eFR
Description code
Estop spring element required by each operator to secure operator & contact blocks eFR
Rear elements (2)
Rear elements (2)
eFR
eFR
nDRR 50Rt
eF 220.1
eF 220.1
1. Front element2. Middle element3. Rear element
1. Front element2. Middle element3. Rear element
eDRR 40 Rt
nDRR 50 Rt
1
1
2
2
3
3
Discount code c5
eDRR 40 Rt
12.3.2. 12.3.3.
12-523
Stock Status:Normally stocked /Not normally stocked
12
12.4. Selector Switches (2 & 3 Positions)12.4.1. Standard Range
order codes - 2 Position operator
order codes - 3 Position operator
order codes - supplied complete with Holder & contact Block
symbol Description code
Short handle, stay put operation 60DegB to C
M2SS110B
Long handle, stay put operation 60DegB to C
M2SS410B
Short handle, stay put operation 90Deg A to C
M2ss210B
Long handle, stay put operation 90DegA to C
M2SS510B
Short handle, spring return operation from the right 60DegC to B
M2SS310B
Long handle, spring return operation from the right 60Deg C to B
M2SS610B
symbol Description code
Short handle, stay put operation 90Deg A to B to C
M3ss110B
Long handle, stay put operation 90Deg A to B to C
M3SS410B
Short handle, spring return operation 90DegA to B and C to B
M3SS210B
Long handle, spring return operation 90Deg A to B and C to B
M3SS510B
Short handle, momentary from the left A to B, Spring return from the right C to B
M3SS310B
Short handle, momentary from the left A to B, Stay put from the right C to B
M3SS710B
Description code
2 Position, stay put operation 60Deg short handle with 2 N/O contacts M2SS140B-20
2 Position, stay put operation 90Deg short handle with 1 N/O & 1 N/C contact M2ss240B-11
2 Position, stay put operation 90Deg short handle with 2 N/O contacts M2SS240B-20
3 Position, stay put operation 90Deg short handle with 2 N/O contacts M3SS140B-20
Front elements (1)
complete Position selector switches
non-illuminated
M2ss110B
Discount code l10
Description code
1 N/O McBH-10
1 N/C McBH-01
1 N/O & 1 N/C McBH-11
2 N/C McBH-02
2 N/O McBH-20
additional contact blocks
1 N/O McB10
1 N/C McB01
order codes - complete contact Block & Holder assembly
Rear elements (2)
1. Front element2. Rear element
1
2
M2ss410B
McBH-02
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.4. Selector Switches (2 & 3 Positions) Stock Status:
Normally stocked /Not normally stocked
12
12.4.1. Standard Range
Description code
1 N/O McBH-10
1 N/C McBH-01
1 N/O & 1 N/C McBH-11
2 N/C McBH-02
2 N/O McBH-20
additional contact blocks
1 N/O McB10
1 N/C McB01
order codes - complete contact Block & Holder assembly
Rear elements (2)
order codes - 2 Position illuminated operator short Handle
order codes - 3 Position illuminated operator short Handle
Front elements (1)
illuminated
symbol Description code
stay put operation 60Deg B to c
Red M2SS111R
Green M2SS111G
Yellow M2SS111Y
Blue M2SS111L
Clear M2SS111C
symbol Description code
stay put operation 3 x 60Deg a, B, c
Red M3SS111R
Green M3SS111G
Yellow M3SS111Y
Blue M3SS111L
Clear M3SS111C
1. Front element2. Rear element
1
2
M2ss111R
M2ss111Y
McBH-02
Discount code l10
12-525
12.4. Selector Switches (2 & 3 Positions) Stock Status:Normally stocked /Not normally stocked
12
eWt .../eWs ...
eWt ... .1/eWs ... .1
12.4.2. Heavy Duty Range
symbol Description code
Spring Return 1 eWt21
Spring Return 1, 46mm Long Lever EWT21.1
Latched 2 Position eWs21
Latched 2 Position, 46mm Long Lever EWS21.1
symbol Description code
Spring Return 2 eWt32
Spring Return 2, 46mm Long Lever
EWT32.1
Latched 2 Position eWs32
Latched 2 Position, 46mm Long Lever
EWS32.1
Maintained Spring-Return, Latched Left / Spring Return Right
EWTS32
Maintained Spring-Return, Latched Left / Spring Return Right, 46mm Long Lever
EWTS32.1
Maintained Spring-Return, Spring Return Left / Latched Right
EWTS321
Maintained Spring-Return, Spring Return Left / Latched Right, 46mm Long Lever
EWTS321.1
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
order codes - contact Block
order codes - contact Block
Rear elements (2)
Rear elements (2)
order codes - selector switch operator
order codes - selector switch operator
Front elements (1)
Front elements (1)
Heavy Duty selector switches – non-illuminated 2 Position
Heavy Duty selector switches – 3 Position
1. Front element2. Rear element
1. Front element2. Rear element
1
1
2
2
eWt21
eWt32
eF033.1
eF033.1
Discount code c5
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.4. Selector Switches (2 & 3 Positions) Stock Status:
Normally stocked /Not normally stocked
12
12.4.3. IP69K Range
Discount code c5
symbol Description code
Spring Return 1 nWt 21 Ws
Spring Return 1, 46mm Long Lever nWt 21.1 Ws
Latched 2 Position nWs 21 Ws
Latched 2 Position, 46mm Long Lever nWs 21.1 Ws
symbol Description code
Spring Return 2 nWt 32 Ws
Spring Return 2, 46mm Long Lever
nWt 32.1 Ws
Latched 2 Position nWs 32 Ws
Latched 2 Position, 46mm Long Lever
nWs 32.1 Ws
Maintained Spring-Return, Spring Return Left / Latched Right
nWts 321 Ws
Maintained Spring-Return, Spring Return Left / Latched Right, 46mm Long Lever
nWts 321.1 Ws
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
order codes - contact Block
order codes - contact Block
Rear elements (2)
Rear elements (2)
order codes - selector switch operator
order codes - selector switch operator
Front elements (1)
Front elements (1)
iP69K selector switches – non-illuminated 2 Position
iP69K selector switches – 3 Position
1. Front element2. Rear element
1. Front element2. Rear element
1
1
2
2
nWt 21
nWt 32
eF033.1
eF033.1
nWt .. Ws
nWt .. Ws
12-527
Stock Status:Normally stocked /Not normally stocked
12
12.5. Selector Switches (2 to 12 Pos.)12.5.1. Heavy Duty Range12.5.2. IP69K Range
Discount code c5
number of steps switching angles installation depth (mm) l code
3 Steps 60⁰ 60 EWSE3K
4 Steps 60⁰ 60 EWSE4K
5 Steps 60⁰ 69.5 EWSE5K
6 Steps 60⁰ 69.5 EWSE6K
7 Steps 45⁰ 78 EWSE7K
8 Steps 45⁰ 78 EWSE8K
9 Steps 30⁰ 87.5 EWSE9K
10 Steps 30⁰ 87.5 EWSE10K
11 Steps 30⁰ 97 EWSE11K
12 Steps 30⁰ 97 EWSE12K
number of steps switching angles installation depth (mm) l code
2 Steps 60⁰ 69.5 NWSE2K
3 Steps 60⁰ 60 NWSE3K
4 Steps 60⁰ 60 NWSE4K
5 Steps 60⁰ 69.5 NWSE5K
6 Steps 60⁰ 69.5 NWSE6K
7 Steps 45⁰ 78 NWSE7K
8 Steps 45⁰ 78 NWSE8K
9 Steps 30⁰ 87.5 NWSE9K
10 Steps 30⁰ 87.5 NWSE10K
11 Steps 30⁰ 97 NWSE11K
12 Steps 30⁰ 97 NWSE12K
order codes - selector switch operator
order codes - selector switch operator
selector switches – 2 to 12 Position - Heavy Duty Range
selector switches – 2 to 12 Position - iP69K Range
eWse ...
nWse ...
12.5.1. 12.5.2.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRolstock status:normally stocked /Not normally stocked
12
12.6. Key-Operated Selector Switches12.6.1. Standard Range
symbol Description code
Image Stay put operation 60Deg B to C Key removable in both positions
M2SSK1101
Stay put operation 60Deg B to C Key removable in B only
M2ssK2101
Image Spring return operation from the right 60Deg C to B key removable in B only
M2SSK3101
symbol Description code
Image Stay put operation 90Deg A to B to C Key removable in both positions
M3SSK1101
Stay put operation 90Deg A to B to C Key removable in B only
M3SSK2101
Image Spring return operation to centre 90Deg A to B and C to B Key removable in B only
M3ssK3101
Image Stay put operation from the left A to B, Spring return from the right C to B, Key removable in A only
M3SSK4101
Stay put operation from the left A to B, Spring return from the right C to B, Key removable in all positions
M3SSK5101
order codes - 2 Position operator with Key operation
order codes - 3 Position operator with Key operation
Front elements (1)
order codes - complete contact Block & Holder assembly
Rear elements (2)
Discount code l10
1. Front element2. Rear element
1
2
M2ssK1101
McBH-11
Description code
1 N/O McBH-10
1 N/C McBH-01
1 N/O & 1 N/C McBH-11
2 N/C McBH-02
2 N/O McBH-20
additional contact blocks
1 N/O McB10
1 N/C McB01
12-529
12.6. Key-Operated Selector Switches Stock Status:Normally stocked /Not normally stocked
12
Discount code c5
12.6.2. Heavy Duty Range
1. Front element2. Rear element
1
2
est21s1
eF10.1
Description code
Key-Operated Spring Return 1 x 55⁰, Key withdrawal position 0 est21s1
Key-Operated Latched 2 Position x 90⁰, Key withdrawal position 0 ESS21S1
Key-Operated Latched 2 Position x 90⁰, Key withdrawal position 1 ESS21S2
Key-Operated Latched 2 Position x 90⁰, Key withdrawal position 0+1 ESS21S12
Description code
Key-Operated Spring Return 2 x 35⁰, Key withdrawal position 0 ESTS32S2
Key-Operated Latched 3 Position x 55⁰, Key withdrawal position I ESS32S1
Key-Operated Latched 3 Position x 55⁰, Key withdrawal position 0 ESS32S2
Key-Operated Latched 3 Position x 90⁰, Key withdrawal position II ESS32S3
Key-Operated Latched 3 Position x 90⁰, Key withdrawal position I+0+II ESS32S123
order codes - selector switch operator
order codes - selector switch operator
Front elements (1)
Front elements (1)
Key-operated selector switches – 2 Position
Key-operated selector switches – 3 Position
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
order codes - contact Block
order codes - contact Block
Rear elements (2)
Rear elements (2)
ess.../est...
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRolstock status:normally stocked /Not normally stocked
12
12.7. Toggle Switches
12.7.2. Heavy Duty Range12.7.1. Standard Range
Description code
Toggle Switch EKS
order codes - supplied without Rear elements – supplied separately
order codes - selector switch operator
Front elements (1)
Front elements (1)
Heavy Duty Range
standard Range
order codes - complete contact Block & Holder assembly
order codes - contact Block
Rear elements (2)
Rear elements (2)
symbol Description code
2 Position maintained – Vertical Operation A to C MTS110B
3 Position spring return – Vertical operation A to B and from C to B
MTS210B
3 Position maintained – Vertical operation A to B and from C to B
MTS310B
1. Front element2. Rear element
1. Front element2. Rear element
1
1
2
2
Mts110B
eKs
McBH-11
eF033.1
Discount code l10Discount code c5
eKs
Description code
1 N/O McBH-10
1 N/C McBH-01
1 N/O & 1 N/C McBH-11
2 N/C McBH-02
2 N/O McBH-20
additional contact blocks
1 N/O McB10
1 N/C McB01
Description code
1 N/O eF03.1
1 N/C eF10.1
2 N/O eF033.1
1 N/O & 1 N/C eF103.1
2 N/C eF220.1
12.7.1. 12.7.2.
12-531
Stock Status:Normally stocked /Not normally stocked
12
12.8. Buzzers
Description code
Buzzer, metal bezel, supply voltage 24VDC eMes
Contact Block / Mounting Flange supplied
Description code
24V AC/DC KB14010
230V AC/DC KB14040
order codes - audible signal Device
order codes - Frequency 2400Hz, loudness Min 80dB
Front elements (1)
Heavy Duty Range - Buzzer
standard Range - Buzzer
Discount code l10Discount code c5
12.9. Potentiometer Drive
Description code
Rotary Potentiometer Drive to suit 6mm shaft EDAN 6
Description code
Rotary Potentiometer Drive to suit 6mm shaft nDan 6
Description code
Operator and 5kOhm resistive element MT105B
Operator and 10kOhm resistive element Mt310B
Legend plate for potentiometer dial engraved plate, Aluminium, 29.6 x 44.5mm, Text, Scale 0-10 SK 615.562-88
order codes - audible signal Device
order codes - audible signal Device
order codes - Dial & element supplied complete, legend Plate supplied separately
Front elements (1)
Front elements (1)
Heavy Duty Range - Potentiometer Drive
iP69K Range - Potentiometer Drive
standard Range - Potentiometer Drive
order codes - contact Block
Rear elements (2)
Description voltage code
Terminal Block 24V AC/DC el
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRolstock status:normally stocked /Not normally stocked
12
12.10. Assembled Stations12.10.1. Enclosed Pushbutton Stations12.10.2. Blank Enclosures
Description code
Enclosed 40mm twist to reset Emergency Stop operator with 2 N/C contacts MEPY11005
Enclosed 40mm push to reset Emergency Stop operator with 2 N/C contacts MEPY11015
Description code
1 N/O McB10B
1 N/C McB01B
Description code
DIN rail adaptor MA18131
DIN rail adaptor when only one element is used MA18001
Description code
Full voltage lamp block 6-240V AC/DC for Ba9s filament or LED lamp, max 2W MLB1B
Diode resistor lamp block 115V AC for Ba9s 60V filament bulb, max 1.2W MLB2B
Diode resistor lamp block 240V AC for Ba9s 130V filament bulb, max 2W MLB3B
no. Hole cut-outs Description code
1 hole Dark Grey/Light Grey MEP1
1 hole Yellow/Light Grey MEPY1
2 hole Dark Grey/Light Grey MeP2
3 hole Dark Grey/Light Grey MeP3
4 hole Dark Grey/Light Grey MEP4
6 hole Dark Grey/Light Grey MEP6
Notes:(1) When using base mount contacts a spacer needs to be specified - Order Code MA18150.
Description code
Enclosed stop (red) / start (green) station with momentary operators and contact blocks. Green (1 N/O) Red (1 N/C)
MEP21001
order codes - single Hole Plastic enclosure iP66 (supplied assembled)
order codes - Base Mount contacts for mounting into plastic enclosures
order codes - Din Mount adapter for Base Mount contacts
order codes - Base Mount Ba9s lamp Block
order codes - supplied bare without front or rear elements
order codes - two Hole Plastic enclosure iP66 (supplied assembled)
enclosed Pushbutton stations
Blank enclosures
Blank Plastic enclosure iP66 (1)
Discount code l10
MeP1
MePY1
MlB1B
MeP6
MePY11005
MeP21001
12-533
Stock Status:Normally stocked /Not normally stocked
12
12.11. Accessories12.11.1. Standard Range
Description code
1 N/O McBH-10
1 N/C McBH-01
2 N/O McBH-20
2 N/C McBH-02
1 N/O & 1 N/C McBH-11
1 N/O and full voltage lamp block w/o lamp McBH-101
1 N/C and full voltage lamp block w/o lamp MCBH-011
1 N/O & 1 N/C full voltage lamp block w/o lamp MCBH-111
Description code
1 N/O McB10
1 N/C McB01
* Supplied without holder. Holder must be ordered separately
Primary voltage secondary voltage code
110 -127V AC 6V AC KTR11001
220 – 250V AC 6V AC KTR11002
220 – 250V AC 24V AC* KTR11012
380 – 420V AC 24V AC* KTR11013
* Can be used with LED
Description code
2 N/O MCB20
2 N/C MCB02
1 N/O + 1 N/C MCB11
* Supplied without holder. Holder must be ordered separately
Description code
Full voltage lamp block 6-240V AC/DC for Ba9s filament or LED lamp, max 2W MLB1
Diode resistor lamp block 115V AC for Ba9s 60V filament bulb, max 2W MLB2
Diode resistor lamp block 240V AC for Ba9s 130V filament bulb, max 2W MLB3
Resistor lamp block 24v AC/DC supply for Ba9s LED MLB4
Resistor lamp block 24v AC/DC supply for Ba9s filament bulb MLB5
Description code
For maximum of three rear elements McBH00
For maximum of five rear elements MCBH500
order codes - complete contact Block / lamp Block & Holder assembly
order codes - Panel Mount contact Blocks – single*
order codes - Panel Mount contact Blocks – Double*
order codes - Panel Mount lamp Blocks – Double*
order codes - Rear element Holders
order codes -lamp Blocks (For 6 or 24V filament bulb and 24V LED. Rated Power 1.5W)
Rear elements
McBH-11
McBH-111
McB10
McB11
MlB1
KtR11001
McBH00 McBH500
Discount code l10
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.11. Accessories Stock Status:
Normally stocked /Not normally stocked
12
12.11.1. Standard Range
Primary voltage secondary voltage code
220 - 250V AC 24V AC* KTR12012
380 - 420V AC 24V AC* KTR12013
* Can be used with LED
order codes - transformer Block for illuminated operators(Intended to supply a 1.2W filament bulb mounted in lamp block MLB-1 only)
Description code
Diode Block MDB1
Rated voltage (v) Rated current (ma) Rated output (W) service life (h) luminance (mcd) code
6 200 1.2 10000 350 5911 086-11
12 100 1.2 10000 320 5911 086-12
24 50 1.2 10000 280 5911 086-13
30 40 1.2 10000 250 5911 086-4
48 42 2 6000 500 5911 086-5
60 20 1.2 5000 190 5911 086-14
110 18 2 7500 250 5911 086-7
130 15 2 7500 120 5911 086-15
colour Rated current (ma) luminance (mcd) code
Rated voltage 24v ac/Dc service life > 50 000h
Red 15 250 sF921R2021
Green 15 800 sF921R2022
Yellow 15 250 SF921R2023
Blue 15 400 SF921R2024
White 15 500 sF921R2025
Rated voltage 230v ac service life > 25 000h
Red 4 60 sF921R2221
Green 4 500 sF921R2222
Yellow 4 70 SF921R2223
Blue 4 220 SF921R2224
White 4 350 sF921R2225
order codes - Diode BlockTo be used if several lamps are to be connected to a common lamp-test pushbutton. A diode must be connected in series with each lamp. The diode block snaps onto the lamp block or is placed at the side.
order codes - Filament BulbsBa9s base type of current: AC/DC (A lamp changing tool is required for changing bulb)
order codes - leD’sWith one diode chip mounted on a Ba9s base. Choose the same color for the LED and the lamp cap or else use a clear lamp cap. For white light use white LED with clear lamp cap. At DC the lamp base have to be connected to cathode (-) and the bottom contact to anode (+)
KtR12012
MDB1
Discount code l10
12-535
12.11. Accessories Stock Status:Normally stocked /Not normally stocked
12
12.11.1. Standard Range
legend plate holders with inserts
• Holder of black plastic• Insert of brushed aluminium on black plastic• The insert is securely retained in a pocket and can be removed.• 3mm high text in typeface Helvetica
Ka18072
Ma18130
Discount code l10
Description code
legend plate holder
Black KA18120
inserts
Of brushed aluminium on black plastic without text or symbol KA18121
inserts with text/symbolof brushed aluminium on black plastic with text
Close MA61036
Open MA61037
On MA61038
Off MA61039
Forward MA61056
Reverse MA61057
Down MA61042
Up MA61043
Start MA61044
Stop MA61045
Reset MA61047
Run MA61054
Fault MA61058
inserts for two-position selector switchesof brushed aluminium on black plastic with text or symbol
Pos. 21 Off Pos. 22 On MA61073
Pos. 31 Man Pos. 33 Auto MA61085
inserts for three-position selector switchesof brushed aluminium on black plastic with text or symbol
Pos. 31 Man Pos. 32 Off Pos. 33 Auto MA61086
emergency stop legend plate-suitable for control panels and 1 hole metal enclosure KeM1engraved plate of aluminiumYellow with black textQuantity per package: 10
Text: Emergency Stop SK 615.546-2
emergency stop legend plate-suitable for 1 hole plastic enclosures MeP1 & MePY1engraved plate of aluminiumYellow with black textQuantity per package: 10
Text: Emergency Stop Ma61101
emergency stop legend plate-suitable for control panels and 1 hole metal enclosure KeM1engraved plate of aluminium 29.6 x 44.5mm
Text: Scale 0 - 10 SK 615.562-88
Note: For the full range of legend plates, pushbutton engraved inserts and pilot light diffuser texts, contact customer support.
order codes
Width 48.5 mmHeight 44.5 mm
For two-position. selector switch
For three-position selector switch
▲
▲
30
▲
▲
47
Description code
lamp changing tool
For LEDs and for bulbs KA18072
Blanking plug
Black plastic MA18130
order codes
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.11. Accessories Stock Status:
Normally stocked /Not normally stocked
12
12.11.2. Heavy Duty Range
Description code
Aluminium version, aluminium colour-anodised, with sealInscription area: dark grey RAL 7012Inscription area: 8 mm × 28 mm1 line: max. 8 letters, 5 mm high1 line: max. 11 letters, condensed type, 4 mm high2 lines: per line max. 13 letters, condensed type, 2 mm high
MZSO
Plastic versionInscription area stick-in, dark-grey RAL 7021, aluminiumcolouranodised highlighted, inscription area: 10 × 26 mm1 line: max. 8 letters, 5 mm high1 line: max. 10 letters, condensed type, 4 mm high2 lines: per line max. 12 letters, condensed type, 2 mm high
KZSO
Description code
Installation diameter 22.3 mm:Aluminium, anodised, with sealFront panel thickness: 1.5–6 mm
MBN
Description code
Installation diameter 22.3 mm:Front panel seal
MDT-8/PTFE
Description code
Aluminium, anodised, with seal and thrust washerThe maximum front panel thickness is thus reduced to 4 mm.
MUe
Description code
Spare key SDS 1
Bulb remover E-LR-4
Mounting tool for bulb replacement K-14
Description code
Print on pushbutton* POA
See next page and many more available on request.
order codes
order codes
order codes
order codes
order codes
order codes
Identification plates
Blanking Plug
Front panel seal
adapter for insertion of 22.5 mm actuators in 30.5 mm holes
Miscellaneous
custom symbols
Discount code c5
12-537
12.11. Accessories Stock Status:Normally stocked /Not normally stocked
12
12.11.3. IP69K Range
Discount code c5
Description code
Adapter 22/30 mm nUe1
Description code
Emergency stop legend plate nDP-70/emergency-stop
Label, H 56.5 mm, B 44.5 mm, V4A version, blank nZso/v4a*
ditto, 1 line with lettering (max. 12 characters) NZSO/1/V4A*
ditto, 2 lines with lettering (max. 12 characters per line) NZSO/2/V4A*
* Longer versions: on request
Description code
Print on pushbutton* NBSY
See below and many more available on request.
Description colour code
Blanking plug metallic nB
order codes
order codes
order codes
order codes
Identification plates
custom symbols
Blanking Plug
adapter for insertion of 22.5 mm actuators in 30.5 mm holes
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol
12
12.12. Joystick Controllers
22.3 mm spring-return joystick switchesSpring-return joystick switches belong to the group of special device designs in the Schmersal delivery range of command and indicator devices.Spring-return joystick switches consist of an actuating head with actuating lever movable in up to 4 directions, and the appertaining contact elements.
Protection class iP 69K
These joysticks have 2mm thick silicone sealing bellows which meet the protection class requirements IP 69K.
terminal markings
The devices are provided with stickers – on the side of the contact elements – that indicate the function of the switching contacts in the position at rest (in the non-actuated position of the device lever). NO contacts (contact marking 13/14) are in this case “green” and NC contacts (contact marking 11/12) have “red” shading. The upper contact marking refers to the upper switching contact and the lower contact marking to the lower switching contact for each contact element. To determine which switching contacts act in the respective direction of actuation, the switching direction is marked A, B, C and D on the device ring with reference to the following diagram. Corresponding to this the switching direction marking A, B, C and D is found on the stickers and it is mandatory to place these at the letter C on the device ring as the proper assembly position.
Devices for installation diameter 22.3 mm are supplied pre-assembled in the form of what is known as a basic device (1) – consisting of the contact element(s) and the actuating head mecha- nism in one part – and the spring return joystick handle
(2) – consisting of the device knob with sealing bellows, actuator ball and knurled nut including sealing.
the basic device
(1) is inserted from the rear of the front plate into the installation diameter and tightened securely by means of the knurled nut
(3) on the frontof the assembly
(2) Both the knurled nut and also the ball
(4) must be unscrewed at the same time.
First, the fixing screws on the basic device (5) must be twisted back until flush so that the maximum front plate thickness of 6mm is available. The fixing screws serve in this case exclusively as an anti-twist lock and must therefore be tightened evenly (lightly) after assembling the device.
12-539
12.12. Joystick Controllers Stock Status:Normally stocked /Not normally stocked
12
Discount code c5
switching Position Quantity contacts code
MKTA32
MKTB32
MKTB32/1x401
MKTC32
MKTC42
MKtc52
MKTC52/2x401
MKTE32
MKTE52
MKTE52/206
order codes
MKtc
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRolstock status:normally stocked /Not normally stocked
12
12.13. Plastic & Metal Enclosures
order codes
order codes
order codes
iP55 thermoplastic enclosures
iP65 Polycarbonate enclosures
thermoplastic & Polycarbonate enclosure accessories
cover internal Dimensions (H x W x D) mm lid screw type code
Opaque 100 x 100 x 50 Stainless Steel le00846
105 x 70 x 50 Stainless Steel le00850
100 x 100 x 80 Stainless Steel LE00851
153 x 110 x 66 Stainless Steel le00852
160 x 135 x 77 ¼ turn plastic LE00854
220 x 170 x 80 ¼ turn plastic le00856
310 x 240 x 110 ¼ turn plastic LE00858
160 x 135 x 150 ¼ turn plastic le00860
220 x 170 x 150 ¼ turn plastic le00862
310 x 240 x 160 ¼ turn plastic LE00864
Clear 153 x 110 x 66 ¼ turn plastic LE00872
160 x 135 x 77 ¼ turn plastic LE00874
220 x 170 x 80 ¼ turn plastic LE00876
310 x 240 x 110 ¼ turn plastic LE00878
160 x 135 x 150 ¼ turn plastic LE00880
220 x 170 x 150 ¼ turn plastic LE00882
310 x 240 x 160 ¼ turn plastic LE00884
Description internal Dimensions (H x W x D) mm code
IP65 Polycarbonate Enclosures 140 x 220 x 140 LE12804
205 x 220 x 140 LE12808
275 x 220 x 140 LE12812
275 x 370 x 140 LE12814
275 x 570 x 140 LE12816
380 x 570 x 140 LE12818
Description size (mm) code
Mounting Plates for enclosures IP55 160 x 135 lP00900
220 x 170 lP00902
310 x 240 LP00904
Mounting Plates for enclosures IP65 140 x 220 LP12842
205 x 220 LP12844
275 x 220 LP12845
275 x 370 LP12846
275 x 570 LP12847
275 x 570 LP12848
Wall mounting brackets for IP65 LA12858
35mm DIN-rail slotted 2m length DR12849
le00856
le00878
le12808
le12818
lP009xx
la12858
Discount code c11
12-541
12.13. Plastic & Metal Enclosures Stock Status:Normally stocked /Not normally stocked
12
order codes
order codes
order codes
order codes
Welded steel enclosures manufactured from 1.5mm steel and painted RAL7035. A galvanised steel mounting plate, 2mm thickness is included with the enclosure. Suitable for indoor use.
Metal internal Door
Rain Hoods
Metal enclosure accessories
iP65 Metal enclosures
Description internal Dimensions (H x W x D) mm code
Internal Door 500 x 400 KC5040K
600 x 400 KC6040K
700 x 500 KC7050K
800 x 600 KC8060K
1000 x 600 KC1060K
1000 x 800 KC1080K
1200 x 600 KC1260K
1200 x 800 KC1280K
Description internal Dimensions (H x W x D) mm code
Rain hood 200 x 150 TT2015K
300 x 150 TT3015K
300 x 200 TT3020K
400 x 200 TT4020K
400 x 250 TT4025K
600 x 250 TT6025K
600 x 300 TT6030K
800 x 300 TT8030K
Description code
Document pocket A4 AA5600
Wall mounting kit (set of 4 pieces) AA1206
Double tongue lock and key (spare part) AA8001
Flush key lock with Yale type key AA8002
Tee handle with Yale type key AA8003
Lock with triangle key insert AA5200
Spare triangle key (plastic) AA5190
Spare triangle key (metal) AA1560
25mm spacer for mounting plate AA8025
50mm spacer for mounting plate AA8050
Description Dimensions (H x W x D) mm code
IP65 Metal Enclosure 300 x 200 x 150 SRN3215K
300 x 300 x 150 SRN3315K
400 x 300 x 200 SRN4320K
400 x 400 x 200 SRN4420K
500 x 400 x 250 SRN5425K
600 x 400 x 200 SRN6420K
600 x 600 x 250 SRN6625K
700 x 500 x 250 SRN7525K
800 x 600 x 300 SRN8630K
1000 x 600 x 300 SRN10630K
1200 x 600 x 300 SRN12630K
1000 x 800 x 300 SRN10830K
1200 x 800 x 300 SRN12830K
le12818
Discount code c11
tt3015K
ts6009
aa5600
aa1206
aa8001aa8002
aa8003
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol
12
12.14. Radio Wireless Control12.14.1. Overview
Jay electronique saFiR Radio Remote control Range
RUGGeD
eRGonoMic
easY to Maintain
scReen
saFetY
The SAFIR range of Radio Remote Controls are the latest release from Jay Electronique. The range consists of two families of Handheld controls, “Beta” and “Gama” and two Bellybox families, “Pika” and “Moka”. All of these families can be configured to offer varying combinations of Buttons, Switches or Joysticks to meet your application needs.
Designed to work under the toughest conditions, our products are built and sized to be extra-rugged. Specially designed seals and protective foams ensure the highest level of strength and tightness.
Very special care has been taken in the design and ergonomics of our solutions to ensure rugged products providing maximum comfort in use day after day.JAY’s remote control buttons provide optimum touch sensitivity and are sized to allow the operator to easily use the radio remote control even when wearing gloves.The buttons are laid out to prevent the operator from mistakenly pressing two buttons at the same time.
By the modular architecture of our systems, maintenance is facilitated to allow reduced-cost repairs.To ensure fast diagnostics and preventive maintenance on the radio control system, fault isolation is achieved easily and efficiently by an indication on the display or by connecting to a PC computer on which maintenance software has been installed (supplied with order).The simple, secure match-up between the operator module and the transceiver makes it easy and fast to replace one of the two components in the event of a failure.
As a standard feature on our Safir solutions, the backlit, anti-reflection, shock-proof, scratch-proof screen displays:• The battery charge level• The behaviour of the radio link• The name of the equipment remote-controlled • Feedback from the equipment controlled and
operating alarms (weight of load, overload, limit switches)
• Fault diagnostics.
sophisticated, intuitive and guided navigation with menus allowing you to :• Configure the application• Integrate a large number of functions• Monitor a specific part of the equipment.
Safety is at the heart of our concept. The Safir product line is certified “SIL 3” per EN 61508 and “PLe” per EN 13849 representing the highest level of safety. Different options are available to enhance the safety of those applications requiring it (infrared startup, action zone limitation, validation buttons, use in ATEX area, function buttons are SIL2 according to EN61508 and PLd according to EN13849). Access to the radio remote control and certain functions can be limited to authorised operators by password (PIN codes).
customisableEach product comes with a software to allow you to customize the display, logos and pictograms which appear on the screen.
12-543
12.14. Radio Wireless Control
12
12.14.2. Products
Beta series
GaMa series
PiKa series
MoKa series
Compact, easy to handle, flexible Operator module2 or 6 function buttons + 2 navigation buttons + start/validation + stop3 different buttons types availableIP65 tightness transmitterIntegrated or Plug-in rechargeable battery Transmitter support chargerSafety stop PLe EN13849 and SIL 3 EN61508 64 frequencies in 433MHz12 frequencies in 869MHz Many options
Robust, Ergonomic, Secure Operator module6 or 10 function buttons + 2 navigation buttons + start/validation + stop3 different buttons types availableIP65 tightness transmitterPlug-in rechargeable batteryTransmitter support chargerSafety stop PLe EN13849 and SIL 3 EN61508 64 frequencies in 433MHz12 frequencies in 869MHzInfrared start-up option
Compact, Ergonomic Operator module1 or 2 joysticks + 4 or 6 function buttons+ 2 navigation buttons + start/validation + stop 6 different buttons types availableIP65 tightness transmitterPlug-in rechargeable batterySafety stop PLe EN13849 and SIL 3 EN61508 64 frequencies in 433MHz12 frequencies in 869MHzDifferent options available
Modular, multifunction Operator module2,3 joysticks or 6 levers + 4 to 16 function buttons + 2 navigation buttons + start/validation + stop6 different buttons types availableIP65 tightness transmitterPlug-in rechargeable batterySafety stop PLe EN13849 and SIL 3 EN61508 64 frequencies in 433MHz12 frequencies in 869MHzDifferent options available
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.2. Products
UR
Uc
UD
XD
compact industrial remote control4 function buttons + start + stop5 different buttons types available Electronic keyLight-weight, compact transmitter IP65 tightness, protective foams Integrated rechargeable battery Transmitter support charger Safety stop PLd EN138496+3 relays64 frequencies in 433MHzInfrared start-up option
standard industrial remote control6 or 8 function buttons + start + stop 3 different buttons types available Electronic keyIP65 tightness transmitter and receiversPlug-in rechargeable battery Safety stop PLd EN138499 or 12 +3 relays64 frequencies in 433MHz12 frequencies in 869MHz
Modular industrial remote control6, 8 or 10 function buttons + start + stop6 different buttons types available Electronic keyIP65 tightness transmitter and receiversPlug-in rechargeable battery Safety stop PLd EN138496, 12 or 18 +3 relays64 frequencies in 433-434MHz12 frequencies in 869MHz64 frequencies in 911-918MHz Infrared start-up optionSpecial functions
Hazardous area rated industrial remote control 6, 8 or 10 function buttons + start + stop 6 different buttons types available Electronic keyIP65 tightness transmitter and receiversPlug-in rechargeable battery Safety stop PLd EN138418 +3 relays64 frequencies in 433-434MHz 12 frequencies in 869MHz
12-545
12.14. Radio Wireless Control
12
12.14.2. Products
orion
isis
Rs
simple industrial remote control1, 2, 4, 6, 8, 12 or 16 function buttons Versions with start/stop buttonsSingle step push buttonsIP65 tightness transmitters and receivers Standard battery or rechargeable battery Transmitter support charger 2,4,8 or 16 + 1relays1 or 18 frequencies in 433-434MHz Programmable
Radio logical signal transfers8 logical signalsIP65 tightness housings4 or 8 relays18 frequencies in 433-434MHz Programmable
Radio emergency stop - Radio validation handle4 function buttons + start/stop or 3 position trigger Light-weight, compact and ergonomic transmitters IP65 tightness, protective foamsIntegrated rechargeable batteryTransmitter support chargerSafety stop PLe EN13849 and SIL 3 EN61508 6 static outputs + 2 safety relays64 frequencies in 433MHzInfrared start-up option
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3. Industry Solutions12.14.3.1. Radio Crane
SOLUTIONS
SOLUTIONS
Your operational needs • Lifting system with 1 or 2 speeds per movement and 3 axes working in an environment which is hazardous to the operators.
solutions
Gama Moka lD XD
Functions and options • Contactless buttons with optimum touch sensitivity in both control positions, even when wearing gloves.• Precise, safe control of crane using screen menus, multi-position selector switches and joysticks.• Optional industrial connector on receiver. • Black box for monitoring use of travelling crane for manufacturer warranty and preventive maintenance purposes.• Information feedback on condition of crane (malfunctions).• Infrared startup.• Information feedback and display, with• indication of weight and warning relative to overshoot of load limit.• Control layout designed for error-free use .
saFetY oveRHeaD tRavellinG cRane
12-547
12.14. Radio Wireless Control
12
12.14.3.1. Radio Crane12.14.3. Industry Solutions
Your operational needs • 1 or 2 axis lifting system with one or two speeds per movement.
solutions
Beta UR
Functions and options • Compact receiver for optimum integration in equipment in just a few seconds.• Infrared startup.
Your operational needs • Master/Slave crane : lifting system using two cranes with two transmitters or two cranes with one transmitter, securing access to selected cranes.• Tandem crane : lifting system using several travelling cranes to lift a load using a single transmitter• Pitch & Catch crane : lifting system shared between two users, using two transmitters inhibited against simultaneous control of the crane.
solutions
Pika Beta Gama UD
Functions and options • Built-in horn on transceiver.• Black box for monitoring use of travelling crane for manufacturer warranty and preventive maintenance purposes. • Information feedback on condition of crane (malfunctions).• Infrared startup.• Indication of weight and warning relative to overshoot of load limit.• Control layout designed for error-free use . Commands conditioned in accordance with crane limit switches.
Your operational needs • Control of moving loads attached to carriers between different operator workstations.
solutions
Beta UD
Functions and options • Flexible match-up between operator and desired carrier.• Special bi-manual button for release of carrier
Hoist, MonoRail, JiB cRane, WincH
MasteR/MasteR, MasteR/slave, tanDeM, PitcH & catcH cRanes
oveRHeaD conveYoR
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.2. Radio Safe12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Safe intervention in machine area for manual control (adjustment or maintenance)• Safe intervention in a zone on a machine which is operating (normal or downgraded operation) for monitoring or fault diagnostics
solutions
Beta UR Rs
Functions and options • LCD display and scrolling menus for selection and control of machine (or part of a machine)• High programming flexibility (adaptable to application)• Limitation of action zone• ”Deadman“ detection and isolated worker safety system• Infrared startup• Special bi-manual button (movement validation)• BUS interface on receiver for enhanced compactness and connectivity
Maintenance inteRvention / aDJUstMent on an aUtoMateD MacHine
12-549
12.14. Radio Wireless Control
12
12.14.3.2. Radio Safe12.14.3. Industry Solutions
Your operational needs • Wireless control of handling truck.
solutions
Beta PiKa
Functions and options • Secure controls
• Truck movements are controlled safely• Action zone around truck is limited• Precision manoeuvres by proportional commands
Your operational needs • Transmission of a secure emergency stop command between a stationary piece of machinery and a mobile piece of machinery (automatic crane, overhead or floor-mounted conveyor, handling carriage...)
solutions
Rs
Functions and options • Rail-DIN transmitter and receivers for integration in cabinet
Your operational needs • Control of machine startup and/or movement functions.
solutions
orion Beta
Functions and options • LCD display and scrolling menus for selection and monitoring of machine (or part of a machine)• High programming flexibility (adaptable to application)• Industrial connector• BUS interface to limit number of cables required
• Flexible control system (wide range of applications)
Your operational needs • Control of lifting functions of a table used to raise equipment in a workshop. • Control of inclination when this function is used.
solutions
orion UR Beta
Functions and options • Compact transmitter and user-friendly MMI • Flexible, easy selection• Industrial connector • Information feedback
• Compact transmitter and receiver, easy connection to equipment• Multiple selection of lift tables
selF-PRoPelleD HanDlinG
secURe eMeRGencY stoP oF MoBile eQUiPMent
ManUal contRol MacHine
liFt taBle anD tiPPeR
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.3. Radio Green12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Remote control of a fixed or mobile shearing or compacting press working from a crane.
solutions
Moka
Functions and options • Customisable, modular ergonomics (selector switches, keyswitches, potentiometer)• Information feedback for machines controlled.• Industrial connector• BUS interface to limit cable requirements
• Operator module can be used while battery is being charged from loading crane cab• Enhanced productivity (one operator safely handles two machines)
iRon anD steel scaRP PRess (sHeaRinG anD coMPactinG)
12-551
12.14. Radio Wireless Control
12
12.14.3.3. Radio Green12.14.3. Industry Solutions
Your operational needs • Control of a stationary or mobile (tracked) brush chipper used for recycling purposes
solutions
Beta UD PiKa
Functions and options • Operator module availability, including charging mode on holder• Remote installation of operator module antenna for control from a loading machine• Action radius limitation for certain dangerous movements• Anti-condensation pellet• Information feedback• Backlit LCD display for indication of equipment alarms (jamming)• Monitoring of ambient temperature to improve battery service life.
• Grinder emergency stop from remote location• Allows you to manage adjustment and unjamming of equipment
Your operational needs • Manual control of an equipment using a radio remote control (conveyor, hopper, baling press, ...) to perform an adjustment, a test following maintenance or unjam a machine.)
solutions
Beta
Functions and options • Backlit LCD display for easy selection of equipment controlled and intervention area• Special bi-manual button for validation of each command to avoid any handling mistakes.• Management of manual and automatic modes by detection of transmitter on charger.• Device holder to keep operator hands free • Optional BUS interface for receiver
• Optimum safety for operator and his environment• Allows you to select equipment to be controlled• ”Deadman“ detection and isolated worker alarm system
Your operational needs • Safe control of rake movements (lifting of grids, translation)• Control of auxiliary pumps in maintenance mode for treatment plant
solutions
Beta
Functions and options • Anti-condensation pellet for improved resistance to humidity• User-friendly selection of components on display• Infrared startup
• Compact equipment• High resistance to humidity
Your operational needs • Remote control of a high pressure pump used for cleaning of industrial and infrastructure equipment (on/off, pressure adjustment)• Control of vacuuming machine or gun for cleaning of industrial equipment, public works and farming equipment
solutions
orion Beta
Functions and options • LCD display for information feedback relative to equipment (pressure)• Anti-condensation pellet• Monitoring of ambient temperature to improve service life of batteries• Carrying strap and holder
• Extra-rugged (resistant to humidity, mud, water)• Allows selection of several machines and numerous functions
BRUsH GRinDeR anD cHiPPeR
soRtinG centeR eQUiPMent (conveYoR, BalinG PRess), caRDBoaRD coMPactoRs anD Plastic GRinDeRs
WateR tReatMent eQUiPMent
PRessURe cleaneR, vacUUM cleaneR anD aiR GUn
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.4. Radio Lift12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Control of equipment (translation and axles) for correct, safe positioning on rails.
solutions
Pika
Functions and options • Wire-type backup connection for optimum use of equipment• Anti-condensation pellet• Compact receiver with built-in antenna for quick and easy installation• Joystick with movement validation • Safety keyswitch• Toggles for additional functions• Limitation of action zone for certain movements
• Extra-rugged (resistant to impacts, weather)• Operator stays clear of equipment during dangerous phases when positioning lift on rail• Risks related to cable control are eliminated
selF-PRoPelleD Rail anD WHeel MoUnteD liFt
12-553
12.14. Radio Wireless Control
12
12.14.3.4. Radio Lift12.14.3. Industry Solutions
Your operational needs • Remote control of all lift functions using same transmitter : rotation, translation, spreading of tracks, positioning of stabilisers, lifting of platform
solutions
Moka
Functions and options • Two-mode configuration to manage movement / stabilisation, then elevation of platform using the same radio remote control• LCD display showing the work mode selected and providing customised information feedback (alarms)• Detection of transmitter in platform to authorise lifting• Anti-condensation pellet• Toggles for additional functions • Wire-type backup connection• BUS interface on receiver for connection to equipment in just a few seconds.
• Risks related to cable control are eliminated• Movements are secured (no lifting possible from ground)
Your operational needs • Control of elevator cabin for elevator equipment assembly and renovation operations
solutions
UR Beta
Functions and options • A compact radio control solution (transportable).
Your operational needs • Control of equipment for inspection and maintenance operations to ensure operator safety
solutions
Beta
Functions and options • LCD display for sensor fault indication• Industrial connector for quick installation in just a few seconds• Detects when transmitter is not on its charger (radio control / desk control modes interlocked)• Optional bus receiver• Magnetic studs for quick installation
• ”Deadman“ detection and isolated worker alarm system• Movements validated by unintentional bi-manual control
Your operational needs • Control of ski lift (stop, start, +/- speed, control of gates) while monitoring automatic operation• Control of service platform (forward/reverse) for maintenance work
solutions
Beta Rs
Functions and options • Validation trigger ensuring operator safety • LCD display for function selection• Detection of absence of transmitter on charger (radio control / desk control modes interlocked)• Anti-condensation pellet• Carrying strap and holder• Operator identification by PIN code• ”Deadman“ detection and isolated worker alarm system• Optional BUS interface on receiver
• Optimum radio performance (maximum range)• Extra-rugged (for tough atmospheric conditions)• Extended endurance even at low temperatures• Efficient monitoring, assistance and immediate intervention in the event of an incident
tRacKeD sPiDeR liFt
BUilDinG elevatoR
escalatoR
sKi liFt
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.5. Radio Farm12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Remote-control of farm equipment functions (liquid manure spreader, plant treatment equipment, seeder, bailing machine) whether self-propelled or hooked up to a tractor.• On-the-ground control of tractor forward movement function for fruit/vegetable gathering
solutions
orion Beta
Functions and options • Industrial connector on receiver for fast connection to equipment in just a few seconds• Extended radio range in an open environment (up to 150m)• Anti-condensation pellet• Single or double-action buttons • Information feedback• BUS interface on receiver for dialogue with machine controller or tractor computer
• Compact, easy to install• Saves time, user-friendly• Resistant to aggressive environment (humidity, mud)
FaRM MacHineRY
12-555
12.14. Radio Wireless Control
12
12.14.3.5. Radio Farm12.14.3. Industry Solutions
Your operational needs • Control of conveyors in manual mode for maintenance and adjustment purposes • Control of opening/closing of hopper and silos for food storage
solutions
orion orion Beta
Functions and options • LCD display for selection and control of desired equipment• Automatic adjustment of frequency channels• Detection of absence of transmitter on charger (control panel inhibition)• Anti-condensation pellet• Monitoring of charging temperature
Your operational needs • Control of main functions of splitters (horizontal and vertical) and debarkers• Monitoring of operator intervening on automatic sawmill machines
solutions
Beta Rs
Functions and options • LCD display and menu for selection of functions• Configurable deadman function• Detection of absence of transmitter on charging base (control panel inhibition)• Anti-condensation pellet • Information feedback
• Extra-rugged• « Deadman » detection and isolated worker alarm system
Your operational needs • Control of winder and water pump on/off functions from a remote location or from tractor cab.
solutions
orion orion
Functions and options • 2 to 16 function buttons + On/Off button• Resistant to aggressive external environments• Compact and ultra-light• Radio range of 150m in open space
Your operational needs • Remote-selection and control of electric stock prod to facilitate milking operations• Control of opening/closure of various barriers and gates associated to the equipment
solutions
orion orion Beta
Functions and options • LCD display and navigation menu for selec- tion of desired function• Extended radio range in an enclosed environment• Automatic adjustment of frequency channels• Anti-condensation pellet • Built-in horn
FooD stoRaGe anD tRansPoRt eQUiPMent (conveYoR, HoPPeR, silo)
saWMill MacHineRY
FielD WateRinG sYsteM
livestocK FolDinG
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.6. Radio Build12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Control of movement of main functions of mobile crushers / sifters, motor speed, startup, jamming, unjamming, belt, unfolding)• Portable emergency stop button for fixed crushers / sifters
solutions
Beta
Functions and options • LCD display for error-free indication of working mode and function selected• Monitoring of ambient temperature to improve battery service life• Anti-condensation pellet • Information feedback
cRUsHeR anD MateRials siFteR
12-557
12.14. Radio Wireless Control
12
12.14.3.6. Radio Build12.14.3. Industry Solutions
Your operational needs • Control of crane lifting movements (telescopic arm and hoist/hook) for work requiring better visibility and precision.
solutions
Moka
Functions and options • LCD display for information feedback (wind speed, overload, maximum offset, functional status) and choice of operating mode• Anti-condensation pellet• Joysticks with movement validation• Monitoring of ambient air temperature to improve battery service life • Wire-type backup solution• BUS interface on receiver
• High movement precision• Ergonomic controls• High level of safety
Your operational needs • Control of arm extension and operation of concrete pump (rate, On/Off).• Remote control of concrete mixers (loading of materials, start/end of cycle, rate, +/- water)
solutions
Beta Moka
Functions and options • Anti-condensation pellet• Monitoring of ambient temperature to improve battery service life• Optional BUS interface on receiver
• Extra-rugged (resistant to impacts, concrete corrosion, weather)• Extensive transmit range
Your operational needs • Control of conveyor belts in manual mode for maintenance or adjustment procedures • Remote control of hopper opening/closing at material storage silos (for example, from a truck)
solutions
orion Beta
Functions and options • Detection of absence of transmitter on charger (interlocks with automatic startup command)• Monitoring of ambient temperature to improve battery service life• “Deadman” detection and isolated worker safety system• Optional BUS interface on receiver
• Flexible match-up between operator and desired equipment• Optimum radiolink performance (range and reliability)
Your operational needs • Control of movement and monitoring of various machine components (mast, digger rotation, motors) for core sampling, consolidation of foundations, and other earth perforation operations.
solutions
Gama Moka
Functions and options • LCD display for information feedback (drilling speed, depth, alarms...)• Anti-condensation pellet• Removable battery• Joysticks with movement validation
• Wire-type backup solution• Toggles for additional functions• Industrial connector for quick connection• Optional BUS interface on receiver
• Numerous functions• Extra-rugged (resistant to impacts, weather, mud)• Adapts to radio environment
MoBile cRane anD cRaWleR cRane
selF-DRiven PUMP, Belt, concRete MiXeR
tRansPoRt anD stoRaGe oF MateRials (conveYoR Belt, HoPPeR)
DRillinG, PeRFoRation anD slicinG MacHineRY
• Adapts to radio environment• Charging support with “operator module forgotten” detection
• Adapts to radio environment• Charging support with “operator module forgotten” detection
• Extra-rugged design (resistant to dust, rocks, weather)• “Deadman” detection and isolated worker alarm system
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.7. Radio Motion12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Manual control of aircraft pushers used to take aircraft out of parking area • Control of aircraft toilet draining system• Control of aircraft de-icing system
solutions
UR Beta
Functions and options • Information feedback on status of equipment (fill level...)• Anti-condensation pellet for enhanced resistance to humidity.
• Extra-rugged (resistant to impacts, weather)
aiRPoRt eQUiPMent : aiRcRaFt PUsHeRs, aiRcRaFt cleaninG anD De-icinG eQUiPMent
12-559
12.14. Radio Wireless Control
12
12.14.3.7. Radio Motion12.14.3. Industry Solutions
Your operational needs • Control a crane or conveyor at a ship loading/unloading port.• Control handling on a ship
solutions
Pika Moka
Functions and options • Information feedback on status of equipment (weight, overload...) • Built-in horn in receiver• Black box for monitoring use of crane for manufacturer’s warranty and preventive maintenance purposes.• Anti-condensation pellet• Intentional action secure joysticks
• Extra-rugged (resistant to impacts, weather)• Highly resistant to humidity.• High movement precision
Your operational needs • Remote-control of movement of a freight locomotive used for switching of wagons in a yard.• The radio remote control is used to move and hook up the wagons to the locomotive, and for braking purposes.
solutions
Pika
Functions and options • Intentional action secure joysticks• Anti-condensation pellet for enhanced resistance to humidity• Information feedback on status of safety components (brakes test...)• Safety keyswitch instead of PIN code• Deadman detection• BUS interface for fast connection to locomotive
• PIN identification for secure access to equipment by a qualified employee.• High movement precision.• Extra-rugged (resistant to impacts, weather)
Your operational needs • Control opening and closure of one or several industrial doors by one or several operators on a lift truck or using a walkie lift truck.
solutions
orion UR Beta
Functions and options • Easy, flexible programming of doors controlled by association of doors to a radio remote control which is easy to implement.• IR-secured selection of door controlled
• Radio system flexibility.• Can control up to 30 doors • Compact and ultra-light
Your operational needs • Control equipment required to install/move/dismantle stage sets, lighting assemblies, stage curtains.
solutions
Beta
Functions and options • IR-secured control of equipment handled
• Optimised machinery handling• LCD display and navigation menu for selection of stage set elements handled.• PIN code identification for secure access to equipment by a qualified employee
PoRt cRane oR conveYoR Belt, anD sHiP HanDlinG eQUiPMent
RailWaY eQUiPMent : RoaD sWitcHes
inDUstRial DooR
liGHtinG anD HanDlinG oF staGe sets
• Radio control availability• ATEX version for transfer of bulk products
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
12. Pilot Devices & RaDio contRol12.14. Radio Wireless Control
12
12.14.3.8. Radio Drive12.14.3. Industry Solutions
SOLUTIONS
SOLUTIONS
Your operational needs • Precision, effortless control of unloading arm• Control of auxiliary engine and worm screw.
solutions
Beta UD
Functions and options • LCD display for information feedback (engine speed, functional status ...)• Receivers mounted on vibration mounts• Recording of number of controls and their duration for preventive maintenance / troubleshooting procedures on vehicle• Recording of events to facilitate on-site and remote diagnostics• Anti-condensation pellet• Monitoring of ambient temperature to improve battery service life• TWO-MODE variant : in addition to its main functions, your remote control can be used to control directional axles or the functions of a tow truck.
• Compact design• Extra-rugged (resistant to impacts, weather, dust)• Assists in preventive maintenance and diagnostics
tRansPoRt oF BUlK anD DRieD FooD
12-561
12.14. Radio Wireless Control
12
12.14.3.8. Radio Drive12.14.3. Industry Solutions
Your operational needs • Selection and control of various truck platforms to facilitate loading and unloading of vehicles.
solutions
Beta
Functions and options • LCD display and navigation menu for selection of truck platforms• Special processing of extreme conditions • Charging support with operator module forgotten detection
• Suitable for vibration encountered on rolling equipment• Anti-condensation pellet• Monitoring of ambient temperature to improve battery service life
• Easy, error-free selection of truck platforms to be controlled• Compact and ergonomic• Easy to use
Your operational needs • Control of various components of auxiliary cranes used for loading and unloading (unfolding of arms, extension of boom, hook/grabber/fork).
solutions
Moka
Functions and options • LCD display for information feedback (overload, oil temperature and pressure, stabilisers alarm ...)• Proportional controls with excellent touch sensitivity• Anti-condensation pellet
• Industrial connector for fast-connection• Limitation of action zone for certain movements• Toggles for additional functions• Wire-type backup solution• Optional BUS interface on receiver
• High movement precision• Optimum visibility• Extra-rugged (resistant to impacts, weather)
Your operational needs • Unloading of tank
solutions
Beta XD
Functions and options • Automatic adjustment of frequency channels• Anti-condensation pellet• Receiver mounted on vibration mounts
• Industrial connector for fast connection • Carrying strap and holder
• High level of safety for use in explosive environment (ATEX approved)• Deadman detection and isolated worker alarm system• Charging support with operator module forgotten detection
Your operational needs • Remote control of various components of truck ( handling arm, hoses, HP pump ...) and portable emergency shutdown to ensure operator protection.
solutions Beta Gama Pika Moka
Functions and options • LCD display for information feedback (engine speed, functional status, pressure level...).• Receivers mounted on vibration mounts• Anti-condensation pellet• Charging support with operator module forgotten detection
• Carrying strap and holder• Wire-type backup solution (Pika and Moka) • Monitoring of charging temperature• Radio signal propagation post• Optional BUS interface on receiver.
• Extra-rugged (resistant to impacts, humidity)• Optimum radio link performance• Deadman detection and isolated worker alarm system• Limitation of action zone for certain movements
veHicle caRRieR
tRUcK-MoUnteD aUXiliaRY cRane
Gas/FUel tRansPoRt
seWeR HYDRocleaninG veHicle
• Extra-rugged (resistant to impacts, weather)• Adapts to radio environment
• Adapts to radio environment• Charging support with operator module forgotten detection• Assists in preventive maintenance and diagnostics
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13.1.1.1. XXX13.1.1. XXX
Section Guide Overview Stock Status:Normally stocked /Not normally stocked
Discount Code C10
13
13. Power Distribution
section 13
13-563
Power distribution
13. Power Distribution 13-56213.1. circuit breakers 13-564
13.1.1. AC Type 13-56413.1.2. DC Type 13-569
13.2. residual current Devices 13-57013.3. Auxiliary elements & Accessories 13-574
13.3.1. Suit AC MCB, RCD & RCBO 13-57413.3.2. Suit DC Circuit Breakers 13-575
13.4. busbars & Accessories 13-57613.5. enclosed isolator 13-57813.6. Mcb consumer enclosures 13-57913.7. switches 13-580
13.7.1. Load Break Switches 13-58013.7.2. Switch Disconnectors 13-58313.7.3. Change Over Switches 13-58513.7.4. Optional Handles 13-58713.7.5. Extended Shafts 13-58913.7.6. Auxiliary Contacts 13-59013.7.7. Fourth Poles & Neutral Links 13-59213.7.8. Terminal Shrouds 13-59313.7.9. Conversion Kits 13-594
13.8. Fuse switch Disconnectors 13-59613.9. Vacuum contactors 13-600
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
Discount Code C10
13
13.1. Circuit Breakers13.1.1. AC Type
s200c 6kA ‘c’ curve
order codes
tripping characteristic kA rating no of Poles rated current (A) code
‘C’ Curve For Residential, commercial & industrial applications for resistive & inductive loads with low inrush currents
6 1 (UBmax 253VAC, 72VDC)
0.5 S201C 0.5
1 S201C 1
1.6 S201C 1.6
2 s201c 2
3 S201C 3
4 s201c 4
6 s201c 6
8 S201C 8
10 s201c 10
13 S201C 13
16 s201c 16
20 s201c 20
25 S201C 25
32 s201c 32
40 S201C 40
50 S201C 50
63 S201C 63
‘C’ Curve For Residential, commercial & industrial applications for resistive & inductive loads with low inrush currents
6 2 (UBmax 440VAC, 125VDC)
0.5 S202C 0.5
1 S202C 1
1.6 S202C 1.6
2 S202C 2
3 S202C 3
4 S202C 4
6 S202C 6
8 S202C 8
10 s202c 10
13 S202C 13
16 s202c 16
20 s202c 20
25 S202C 25
32 s202c 32
40 S202C 40
50 S202C 50
63 s202c 63
‘C’ CurveFor Residential, commercial & industrial applications for resistive & inductive loads with low inrush currents
6 3 (UBmax 440VAC, 125VDC)
0.5 S203C 0.5
1 S203C 1
1.6 S203C 1.6
2 S203C 2
3 S203C 3
4 S203C 4
6 S203C 6
8 S203C 8
10 S203C 10
13 S203C 13
16 S203C 16
20 S203C 20
25 S203C 25
32 S203C 32
40 S203C 40
50 S203C 50
63 S203C 63
s201
s202
s203
13-565
13.1. Circuit Breakers Stock Status:Normally stocked /Not normally stocked
Discount Code C10
13
13.1.1. AC Type
s200K 6kA ‘K’ curve
order codes
tripping characteristic kA rating no of Poles rated current (A) code
‘K’ Curve For Commercial & industrial applications for circuits supplying motors, transformers etc… with high inrush currents
6 1 (UBmax 253VAC, 72VDC)
0.5 S201K 0.5
1 S201K 1
1.6 S201K 1.6
2 S201K 2
3 S201K 3
4 S201K 4
6 S201K 6
8 S201K 8
10 S201K 10
13 S201K 13
16 S201K 16
20 S201K 20
25 S201K 25
32 S201K 32
40 S201K 40
50 S201K 50
63 S201K 63
‘K’ Curve For Commercial & industrial applications for circuits supplying motors, transformers etc… with high inrush currents
6 2 (UBmax 440VAC, 125VDC)
0.5 S202K 0.5
1 S202K 1
1.6 S202K 1.6
2 S202K 2
3 S202K 3
4 S202K 4
6 S202K 6
8 S202K 8
10 S202K 10
13 S202K 13
16 S202K 16
20 S202K 20
25 S202K 25
32 S202K 32
40 S202K 40
50 S202K 50
63 S202K 63
‘K’ Curve For Commercial & industrial applications for circuits supplying motors, transformers etc… with high inrush currents
6 3 (UBmax 440VAC, 125VDC)
0.5 S203K 0.5
1 S203K 1
1.6 S203K 1.6
2 S203K 2
3 S203K 3
4 S203K 4
6 S203K 6
8 S203K 8
10 S203K 10
13 S203K 13
16 S203K 16
20 S203K 20
25 S203K 25
32 S203K 32
40 S203K 40
50 S203K 50
63 S203K 63
s201
s202
s203
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.1. Circuit Breakers Stock Status:
Normally stocked /Not normally stocked
Discount Code C10
13
13.1.1. AC Type
s200M 10kA ‘c’ curve
order codes
tripping characteristic kA rating no of Poles rated current (A) code
‘C’ Curve For Residential, commercial & industrial applications for resistive & inductive loads with low inrush currents
10 1 (UBmax 253VAC, 72VDC)
0.5 S201MC 0.5
1 S201MC 1
1.6 S201MC 1.6
2 S201MC 2
3 S201MC 3
4 S201MC 4
6 S201MC 6
8 S201MC 8
10 S201MC 10
13 S201MC 13
16 S201MC 16
20 S201MC 20
25 S201MC 25
32 S201MC 32
40 S201MC 40
50 S201MC 50
63 S201MC 63
‘C’ CurveFor Residential, commercial & industrial applications for resistive & inductive loads with low inrush currents
10 2 (UBmax 440VAC, 125VDC)
0.5 S202MC 0.5
1 S202MC 1
1.6 S202MC 1.6
2 S202MC 2
3 S202MC 3
4 S202MC 4
6 S202MC 6
8 S202MC 8
10 S202MC 10
13 S202MC 13
16 S202MC 16
20 S202MC 20
25 S202MC 25
32 S202MC 32
40 S202MC 40
50 S202MC 50
63 S202MC 63
‘C’ CurveFor Residential, commercial & industrial applications for resistive & inductive loads with low inrush currents
10 3 (UBmax 440VAC, 125VDC)
0.5 S203MC 0.5
1 S203MC 1
1.6 S203MC 1.6
2 S203MC 2
3 S203MC 3
4 S203MC 4
6 S203MC 6
8 S203MC 8
10 S203MC 10
13 S203MC 13
16 S203MC 16
20 S203MC 20
25 S203MC 25
32 S203MC 32
40 S203MC 40
50 S203MC 50
63 S203MC 63
s201M
s202M
s203M
13-567
13.1. Circuit Breakers Stock Status:Normally stocked /Not normally stocked
Discount Code C10
13
13.1.1. AC Type
s200K 10kA ‘K’ curve
order codes
tripping characteristic kA rating no of Poles rated current (A) code
‘K’ Curve For Commercial & industrial applications for circuits supplying motors, transformers etc… with high inrush currents
10 1 (UBmax 253VAC, 72VDC)
0.5 S201MK 0.5
1 S201MK 1
1.6 S201MK 1.6
2 S201MK 2
3 S201MK 3
4 S201MK 4
6 S201MK 6
8 S201MK 8
10 S201MK 10
13 S201MK 13
16 S201MK 16
20 S201MK 20
25 S201MK 25
32 S201MK 32
40 S201MK 40
50 S201MK 50
63 S201MK 63
‘K’ CurveFor Commercial & industrial applications for circuits supplying motors, transformers etc… with high inrush currents
10 2 (UBmax 440VAC, 125VDC)
0.5 S202MK 0.5
1 S202MK 1
1.6 S202MK 1.6
2 S202MK 2
3 S202MK 3
4 S202MK 4
6 S202MK 6
8 S202MK 8
10 S202MK 10
13 S202MK 13
16 S202MK 16
20 S202MK 20
25 S202MK 25
32 S202MK 32
40 S202MK 40
50 S202MK 50
63 S202MK 63
‘K’ CurveFor Commercial & industrial applications for circuits supplying motors, transformers etc… with high inrush currents
10 3 (UBmax 440VAC, 125VDC)
0.5 S203MK 0.5
1 S203MK 1
1.6 S203MK 1.6
2 S203MK 2
3 S203MK 3
4 S203MK 4
6 S203MK 6
8 S203MK 8
10 S203MK 10
13 S203MK 13
16 S203MK 16
20 S203MK 20
25 S203MK 25
32 S203MK 32
40 S203MK 40
50 S203MK 50
63 S203MK 63
s201M
s202M
s203M
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.1. Circuit Breakers Stock Status:
Normally stocked /Not normally stocked
Discount Code C10
13
13.1.1. AC Type
s280 6kA ‘c’ curve 80A & 100A
order codes
tripping characteristic kA rating no of Poles rated current (A) code
‘C’ Curve For Residential, commercial & industrial applications for resistive & inductive loads with low inrush current
6 1 (UBmax 253VAC, 72VDC)
80 S281C 80
100 S281C 100
2 (UBmax 440VAC, 125VDC)
80 S282C 80
100 S282C 100
3 (UBmax 440VAC, 125VDC)
80 S283C 80
100 S283C 100
Protection and control of the circuits against overloads and short–circuits; protection for resistive and inductive loads with low inrush current.
Applications: residential, commercial and industrial.Standard: AS/NZS 60898, AS/NZS 60947-2, IEC/EN 60898, IEC/EN 60947–2 Icu=6 kA
s282
13-569
13.1. Circuit Breakers Stock Status:Normally stocked /Not normally stocked
Discount Code C10
13
13.1.2. DC Type
order codes - Photovoltaic Dc Main switch
no of Poles rated current (A) code2(UBmax 800 V ...)
32 S802PV-M 32
63 S802PV-M 63
125 S802PV-M 1253(UBmax 1200 V ...)
32 S803PV-M 32
63 S803PV-M 63
125 S803PV-M 1254(UBmax 1200 V ...)
32 S804PV-M 32
63 S804PV-M 63
125 S804PV-M 125
s280PV for Photovoltaic Applications
order codes - Photovoltaic switch
Applications kA rating no of Poles rated current (A) codeSolar Panels & Railways up to 800VDC
10 2 (UBmax 800VDC)
10 S802PV-S 10
13 S802PV-S 1316 S802PV-S 1620 S802PV-S 2025 S802PV-S 2532 S802PV-S 3240 S802PV-S 4050 S802PV-S 5063 S802PV-S 6380 S802PV-S 80100 S802PV-S 100125 S802PV-S 125
Solar Panels & Railways up to 1200VDC
10 3 (UBmax 1200VDC)
10 S803PV-S 1013 S803PV-S 1316 S803PV-S 1620 S803PV-S 2025 S803PV-S 2532 S803PV-S 3240 S803PV-S 4050 S803PV-S 5063 S803PV-S 6380 S803PV-S 80100 S803PV-S 100125 S803PV-S 125
Solar Panels & Railways up to 1200VDC
10 4 (UBmax 1200VDC)
10 S804PV-S 1013 S804PV-S 1316 S804PV-S 1620 S804PV-S 2025 S804PV-S 2532 S804PV-S 3240 S804PV-S 4050 S804PV-S 5063 S804PV-S 6380 S804PV-S 80100 S804PV-S 100125 S804PV-S 125
The specially developed double arcing chamber system of the S800PV guarantees excellent DC current operating properties. The series connection of 2 arcing chambers creates a big rise in the extinction voltage in the case of a short circuit, which means the arc is extinguished safely and very quickly.
Applications: solar panels and railwaysRated operating voltage 800VDC (2pole), 1200VDC (3/4 pole) Standard: AS/NZS 60947-2, IEC/EN 60947–2Icu=5 kA
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution
13
13.2. Residual Current Devices
Functions and classification criteria for RCDs
A residual current operated circuit-breaker is a current sensing protection device which is tripped when the system leaks a significant current to earth.
This device continuously calculates the vector sum of the single-phase system line currents and while the sum is equal to zero allows electricity to be supplied. This supply is rapidly interrupted if the sum exceeds a value preset according to the sensitivity of the device.
residual current operated circuit breakers can be classed according to four parameters:
• Type of construction• Detectable wave form• Tripping sensitivity• Tripping time
Depending on the type of construction, rcDs may be classed as:
• RCBOs (magnetothermic with overcurrent protection)• RCCBs (without overcurrent protection releaser incorporated)• RCD blocks
RCBOs combine, in a single device, the residual current function and the overcurrent protection function typical of MCBs. RCBOs are tripped by both current leakage to earth and overloads and short-circuits and they are self-protecting up to a maximum short-circuit current value indicated on the label.
RCCBs are only sensitive to current leakage to earth. They must be used in series with an MCB or fuse which protects them from the potentially damaging thermal and dynamic stresses of any overcurrents.
These devices are used in systems already equipped with MCBs which preferably limit the specific energy passing through, also acting as the main disconnecting switches upstream of any derived MCBs (eg: domestic consumer unit).RCD blocks are residual current devices suitable for assembly with a standard MCB. IEC/EN 61009 app. G only allows assembly of RCBOs once on site, that is to say outside the factory, using adaptable RCD blocks and the appropriate MCBs. Any subsequent attempts to separate them must leave permanent visible damage. The residual current operated circuit-breaker obtained in this way maintains both the electrical characteristics of the MCB and those of the RCD block.
According to the wave form of the earth leakage currents they are sensitive to, the rcDs may be classed as:
• AC type (for alternating current only)• A type (for alternating and/or pulsating current with DC components)• B type (for alternating and/or pulsating current with DC components and continuous fault current)
Ac type rcDs are suitable for all systems where users have sinusoidal earth current. They are not sensitive to impulsive leakage currents up to a peak of 250A (8/20 wave form) such as those which may occur due to overlapping voltage impulses on the mains (eg: insertion of fluorescent bulbs, X-ray equipment, data processing systems and SCR controls).
A type rcDs are not sensitive to impulsive currents up to a peak of 250 A (8/20 wave form).They are particularly suitable for protecting systems in which the user equipment has electronic devices for rectifying the current or phase cutting adjustment of a physical quantity (speed temperature, light intensity, etc.) supplied directly by the mains without the insertion of transformers and insulated in class I (class II is, by definition, free of faults to earth). These devices may generate a pulsating fault current with DC components which the A type RCD can recognise.
b type rcDs are recommended for use with drives and inverters for supplying motors for pumps, lifts, textile machines, machine tools, etc., since they recognise a continuous fault current with a low level ripple.
13-571
13.2. Residual Current Devices Stock Status:Normally stocked /Not normally stocked
13
Discount code L10
FH200 Ac type
F200 Ac type
order codes
order codes
nominal Fault current (mA)
kA rating no of Poles rated current (A) code
30 6 2 25 FH202 25
40 FH202 40
63 FH202 63
4 25 FH204 25
40 FH204 40
63 FH204 63
100 6 2 25 FH202 25/0.1
40 FH202 40/0.1
63 FH202 63/0.1
4 25 FH204 25/0.1
40 FH204 40/0.1
63 FH204 63/0.1
300 6 2 25 FH202 25/0.3
40 FH202 40/0.3
63 FH202 63/0.3
4 25 FH204 25/0.3
40 FH204 40/0.3
63 FH204 63/0.3
nominal Fault current (mA)
kA rating no of Poles rated current (A) code
30 10 2 25 F202 25
40 F202 40
63 F202 63
4 25 F204 25
40 F204 40
63 F204 63
100 10 2 25 F202 25/0.1
40 F202 40/0.1
63 F202 63/0.1
4 25 F204 25/0.1
40 F204 40/0.1
63 F204 63/0.1
300 10 2 25 F202 25/0.3
40 F202 40/0.3
63 F202 63/0.3
4 25 F204 25/0.3
40 F204 40/0.3
63 F204 63/0.3
Rated short circuit current = 6kA with 63A fuse. For use in both residential and commercial applications. Type AC RCD’s are used where the earth fault waveform is sinusoidal. Refer to page 13-570 for further details. Not suitable for fitting of auxiliaries.
Rated short circuit current = 10kA with 100A fuse. For use in residential, commercial and industrial applications. Type AC RCD’s are used where the earth fault waveform is sinusoidal. Refer to page 13-570 for further details. Suitable for use with S200 auxiliaries.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.2. Residual Current Devices Stock Status:
Normally stocked /Not normally stocked
13
Discount code L10
F200 PV b type for Photovoltaic Applications
Dsn 201 Ac type compact 1 Pole rcbo 1P+n 30mA sensitivity
Ds 201 Ac type rcbo bs Version with blanked neutral terminal 1P+n 2 Module
order codes
order codes
order codes
nominal Fault current (mA)
kA rating no of Poles rated current (A) code
30 10 4 25 F202PVB 25
63 F202PVB 63
300 10 4 25 F202PVB 25/0.3
63 F202PVB 63/0.3
nominal Fault current (mA)
kA rating no of Poles rated current (A) code
30 6 1 6 DSN 201C6
10 Dsn 201c10
13 DSN 201C13
16 Dsn 201c16
20 Dsn 201c20
25 DSN 201C25
32 Dsn 201c32
nominal Fault current (mA)
kA rating no of Poles rated current (A) code
30 6 1 6 DS 201BS-C6
10 Ds 201bs-c10
13 DS 201BS-C13
16 Ds 201bs-c16
20 Ds 201bs-c20
25 DS 201BS-C25
32 Ds 201bs-c32
40 DS 201BS-C40
Rated short circuit current = 10kA with 100A fuse. For use in commercial and industrial applications. Type B RCDs are used where the earth fault waveform in sinusoidal, pulsating DC or smooth DC. Refer to page 13-570 for further details. Type B RCDs are best used where problems from VSDs or similar loads have been encountered.
Rated short circuit current = 6kA. For use in domestic and commercial applications. The DSN201 RCBO provides all of the features of a 2 pole RCBO in a compact housing the same size as a MCB. Advanced technology means the DSN201 can have line connections on either side of the device providing installation convenience. Use interface module SN201-IH to utilise accessories such as shunt trips etc.
Rated short circuit current = 6kA. For use in domestic and commercial applications. The DS201BS RCBO provides an electrically isolated terminal on the neutral connection enabling the DS201BS to be fitted to a standard three phase CM style busbar chassis. Supply neutral must be wired.
13-573
13.2. Residual Current Devices Stock Status:Normally stocked /Not normally stocked
13
Discount code L10
Ds 271 A type 10kA
order codes
nominal Fault current (mA)
kA rating no of Poles rated current (A) code
30 10 1 6 DS271C6
10 Ds271c10
16 Ds271c16
20 Ds271c20
25 DS271C25
32 Ds271c32
40 DS271C40
10 10 1 6 DS271C6/0.01
10 DS271C10/0.01
16 DS271C16/0.01
20 DS271C20/0.01
25 DS271C25/0.01
32 DS271C32/0.01
40 DS271C40/0.01
Function: protection against the effects of sinusoidal alternating earth fault currents: protection against indirect contacts and additional protection against direct (with I∆n=30mA) contacts; command and isolation of resistive and inductive circuits.For use in residential, commercial and industrial applications.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
Discount Code C10
13
13.3.1. Suit AC MCB, RCD & RCBO13.3. Auxiliary Elements & Accessories
signal / Auxiliary contacts
Auxiliary contact / interface Module
bottom Fitting Auxiliary contacts
shunt trip
undervoltage release
Auxiliary contacts
order codes - suitable for Mcbs s200, sn 200 series, rcDs F 200 series, rcbo Ds201
order codes - suitable for Dsn201 rcbo & sn201 Mcb
order codes - suitable for Mcbs s200, s200M, s200P
order codes - suitable for Mcbs s200, s200M, s200P
order codes
order codes - suitable for rcDs F200/Ds201
order codes - suitable for Mcbs s200, rcDs F 200 series. F200 does not accept ‘L’ version auxiliary contacts.
Description contacts code
Signal Contact / Auxiliary Switch S200/F200/DS201 1 CO S2CSH6R
Signal Contact / Auxiliary Switch SN200 1 CO SN201S
Description contacts code
Interface Module / Aux Contact 1 NO, 1 NC SN201-IH
Description contacts code
Auxiliary Contact 1 NC S2CH01
1 NO S2CH10
Description code
Shunt Trip 12…60V AC/DC S2CA1
Shunt Trip 110…415V AC / 110…250V DC S2CA2
Description code
Shunt Trip 12…60V AC/DC F2CA1
Shunt Trip 110…415V AC / 110…250V DC F2CA2
Description contacts code
Auxiliary Contact S200/F200/DS201 1 CO S2CH6R
Auxiliary Contact S200 1 NO / 1 NC S2CH11L
Auxiliary Contact S200 2 NO S2CH20L
Auxiliary Contact S200 2 NC S2CH02L
Description contacts code
Undervoltage release 24V AC S2CUA24AC
Undervoltage release 230V AC S2CUA230AC
Undervoltage release 24V DC S2CUA24DC
Note: Other voltages are available upon request.
Allows remote opening of the device when a voltage is applied.
Offers load protection in the event of a voltage drop (between 70% and 35% of its rated value); positive safety (devices tripping when the voltage is disconnected) emergency stop by means of a button. Suitable for MCBs S200 series and RCDs F200 / DS201 series.
s2csH6r
s2cH6r
s2cH01
s2cA1
s2cuA230Ac
13-575
13.3. Auxiliary Elements & Accessories Stock Status:Normally stocked /Not normally stocked
Discount Code C10
13
13.3.2. Suit DC Circuit Breakers
s800PV series Auxiliary / signal contacts
s800PV series shunt trip
s800PV series under Voltage release
s800PV series remote switching unit
order codes
order codes
order codes
order codes
Description code
Auxiliary Contact S800AUX
Signal Contact S800AUX/ALT
Description code
Shunt Trip 24V AC/DC S800-SOR24
Shunt Trip 110…250V AC/DC S800-SOR250
Description code
Under Voltage Release 24…36V AC/DC S800-UVR36
Under Voltage Release 220…250V AC/DC S800-UVR250
Description code
Remote Switching Unit S800-RSU-H
s800AuX
s800sor
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
Discount Code C10
13
13.4. Busbars & Accessories
busbarsorder codes - For use with Pro M compact series Mcbs s200, rcDs F200 and Ds200
Phases no of pins capacity mm2 Amps code
busbars not to be cut to length (closed design) no end caps required
1 12 10 63 PS 1/12
3 12 10 63 PS 3/12
Phase busbars suitable to cut to length - use end caps Ps-enD 0
1 12 10 63 PS 1/12N
60 10 63 PS 1/60
60 16 80 PS 1/60/16
Phase busbars suitable to cust to lenth - use end caps Ps-enD
2 12 10 63 PS 2/12
58 10 63 PS 2/58
58 16 80 PS 2/58/16
Phase busbars suitable to cut to lenth - use end caps Ps-enD
3 60 10 63 PS 3/60
60 16 80 PS 3/60/16
Phase busbars suitable to cut to length - 1 pole with auxiliary - use end caps Ps-enD
1 38 10 63 PS 1/38/6
end capsorder codes
Description code
2 phase and 3 phase cut to length busbars PS-END
1 phase cut to length busbars PS-END 0
4 phase cut to length busbars PS-ENS 1
13-577
13.4. Busbars & Accessories Stock Status:Normally stocked /Not normally stocked
Discount Code C10
13
rotary operating Mechanism
Locking Device for Mcb and rcbos
Locking Device for Mcbs and switches
Special device mounted locking accessory that remains attached to the device in normal operation. The S2C-PD range can be fitted to protective devices without the need for modification of escutcheons. Clamping securely onto the toggle of the device, the MCB or RCBO can be operated normally with the lock device fitted. When a padlock is fitted and the device has been locked out.
Prevents unauthorised or dangerous operation of the operating lever. An adaptor makes it possible to block the operating lever whether switched ON or OFF. The lever is blocked with a padlock having a cross bar section of 3 or, as the case may be, 6mm max. For multiple devices, one lock may be fitted per pole.
The lock adaptor can be used for all MCBs of the S200, S280 series as well as for switches E200.
Lock adaptor for s800
order codes - For operating of s200 Mcbs in closed distribution boards)
order codes
order codes
order codes - For operating of s800 Mcbs
order codes
Description code
Rotary mechanism (suits 5mm or 6mm shafts) S2C-DH
Note: For 6mm shafts and handles, please refer to the OT switch range. (Handle OH__ and shaft OX__).See Page 13-587 - 13-589
Description code
Locking device - Suits S200 MCB, DS271 RCBO S2C-PD-S200
Locking device - Suits DS201 S2C-PD-DS201
Description code
Rotary mechanism S800RD
Red handle S800RHEEM
Extension shaft 500mm S800RHES
Description code
Locking device 4mm S800PLL
Description crossbar section max. code
Locking devices 3mm SA1
For padlock bar 6mm SA1E
Padlock with 2 keys SA2
Lock adaptor incl. padlock with 3 keys in transparent box
SA3
sA1
sA2
s800rD
s2c-DH
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
Discount Code C10
13
13.5. Enclosed Isolator
enclosed isolator
order codes
Description current rating (A) rating Poles Dimensions H x w x D (mm)
code
Switch Isolator 20 2 83x167x73 WSD220
Switch Isolator 32 2 83x167x73 WSD232
Switch Isolator 45 2 83x167x73 WSD245
Switch Isolator 63 2 83x167x73 WSD263
Switch Isolator 20 4 83x167x73 WSD420
Switch Isolator 32 4 83x167x73 WSD432
Switch Isolator 45 4 83x167x73 WSD445
Switch Isolator 63 4 83x167x73 WSD463
IP66 Switch-Isolator in 2 and 4 pole versions in current ratings from 20-63A.Suitable for switching and isolating applications where a high level of dust and water ingress protection is required.Padlockable in the OFF and ON positions.Utilisation category – AC23A
13-579
Stock Status:Normally stocked /Not normally stocked
13
Discount code c11
13.6. MCB Consumer Enclosures
europa series - iP40 Flush and surface Mount
europa series - iP40 surface Mount consumer unit covers
Order Codes - IP40, flush mount, E/N bars included, white thermoplastic, white or transparent cover
order codes - iP40, surface mount, no e/n bars, white thermoplastic
order codes - iP40, surface mount, e/n bars included, white thermoplastic, white or transparent cover
order codes - iP55, surface mount, no e/n bars, white thermoplastic, transparent cover
Accessories - Flush mount rear protection plate (1mm galvanised steel) - supplied loose.
order codes - iP65, surface mount, e/n bars included, white thermoplastic, transparent cover
Pole capacity Dimensions H x w x D (mm) code white cover code transparent cover
12W (1 x 12p) 180 x 300 x 90 LF12041 LF12061
24W (2 x 12p) 395 x 300 x 90 LF12045 LF12063
36W (3 x 12p) 545 x 300 x 90 LF12048 LF12065
54W (3 x 18p) 545 x 410 x 90 LF12052 LF12067
Lock with key LA12867 LA12867
Pole capacity Dimensions H x w x D (mm) code white cover code transparent cover
12W (1 x 12p) 200 x 305 x 95 LS12442 LS12462
24W (2 x 12p) 350 x 305 x 95 LS12444 LS12464
36W (3 x 12p) 545 x 305 x 120 LS12446 LS12466
54W (3 x 18p) 570 x 380 x 120 LS12447 LS12467
Lock with key LA12864 LA12864
suits enclosure Dimensions H x w x D (mm) code
LF series, 12W flush mount 330 x 280 LF12WPP
LF series, 24W flush mount 530 x 280 LF24WPP
LF series, 36W flush mount 680 x 280 LF36WPP
LF series, 54W flush mount 680 x 380 LF54WPP
Pole capacity Dimensions H x w x D (mm) code
4W (1 x 4p) 220x140x140 LS12744
8W (1 x 8p) 220x205x140 LS12748
12W (1 x 12p) 220x275x140 LS12752
24W (2 x 12p) 370x275x140 LS12754
36W (3 x 12p) 570x275x140 LS12756
Lock with key LA12866
Pole capacity Dimensions H x w x D (mm) code
1W (1 x 1p) 220 x 140 x 140 SPE1
2W (1 x 2p) 140 x 50 x 65 LE12402
4W (1 x 4p) 160 x 95 x 65 LE12404
6W (1 x 6p) 160 x 140 x 65 LE12406
8W (1 x 8p) 200 x 230 x 95 LE12408
Pole capacity Dimensions H x w x D (mm) code
4W (1 x 4p) 180 x 125 x 105 LE12644
6W (1 x 6p) 180 x 160 x 105 LE12646
10W (1 x 10p) 180 x 230 x 105 LE12650
20W (2 x 10p) 320 x 240 x 139 LE12652
Lock with key LA12865
Ls12752
scP
LF12061
LF12065
Lc12st
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
13
Discount code L11
13.7. Switches13.7.1. Load Break Switches
Front operated load break switches, base and Din rail mountingorder codes - 3 pole with pistol handle
order codes - 4 pole with pistol handle
order codes - 3 pole with selector handle
order codes - 4 pole with selector handle
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 ot16F3P
32 25 20 9 ot25F3P
40 40 23 11 OT40F3P
63 63 45 22 ot63F3P
80 80 75 30 ot80F3P
115 100 80 37 ot100F3P
125 125 90 45 ot125F3P
Includes: OXP6X290 extension shaft with 6mm diameter and 290mm in length OHB45J6 IP65 pistol handle for 6mm diameter shaft
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F4P
32 25 20 9 OT25F4P
40 40 23 11 OT40F4P
63 63 45 22 OT63F4P
80 80 75 30 OT80F4P
115 100 80 37 OT100F4P
125 125 90 45 OT125F4P
Includes: OXP6X290 extension shaft with 6mm diameter and 290mm in length OHB45J6 IP65 pistol handle for 6mm diameter shaft
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F3S
32 25 20 9 OT25F3S
40 40 23 11 OT40F3S
63 80 75 22 OT63F3S
80 80 55 30 OT80F3S
115 100 80 37 OT100F3S
125 125 90 45 OT125F3S
Includes: OXS6X250 extension shaft with 6mm diameter and 250mm in length OHB45J6 IP65 selector handle for 6mm diameter shaft
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F4S
32 25 20 9 OT25F4S
40 40 23 11 OT40F4S
63 80 75 22 OT63F4S
80 80 55 30 OT80F4S
115 100 80 37 OT100F4S
125 125 90 45 OT125F4S
Includes: OXS6X250 extension shaft with 6mm diameter and 250mm in length OHB45J6 IP65 selector handle for 6mm diameter shaft
ot16 - 40F3
oH_
ot63 - 80F3
oXP6X_
otP_32_
ot100 - 125F3
oXs6X_
oH_2_
13-581
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.1. Load Break Switches
Front operated load break switches, base and Din rail mountingorder codes - ot16...125 kits, 6 pole with pistol handle
order codes - ot16...125 kits, 8 pole with pistol handle
order codes - ot16...125 kits, 6 pole with direct handle
order codes - ot16...125 kits, 8 pole with direct handle
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F6P
32 25 20 9 OT25F6P
40 40 23 11 OT40F6P
63 63 45 22 OT63F6P
80 80 75 30 OT80F6P
115 100 80 37 OT100F6P
125 125 90 45 OT125F6P
Includes: 2 x OT switches Multi pole adaptor OXP6X290 extension shaft with 6mm diameter and 290mm in length OHB45J6 IP65 pistol handle for 6mm diameter shaft
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F8P
32 25 20 9 OT25F8P
40 40 23 11 OT40F8P
63 63 45 22 OT63F8P
80 80 75 30 OT80F8P
115 100 80 37 OT100F8P
125 125 90 45 OT125F8P
Includes: 2 x OT switches Multi pole adaptor 2 x OTPS 4th pole OXP6X290 extension shaft with 6mm diameter and 290mm in length OHB45J6 IP65 pistol handle for 6mm diameter shaft
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F6D
32 25 20 9 OT25F6D
40 40 23 11 OT40F6D
63 80 75 22 OT63F6D
80 80 55 30 OT80F6D
115 100 80 37 OT100F6D
125 125 90 45 OT125F6D
Includes: 2 x OT switches OHRS3 direct handle Multi pole adaptor
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16F8D
32 25 20 9 OT25F8D
40 40 23 11 OT40F8D
63 80 75 22 OT63F8D
80 80 55 30 OT80F8D
115 100 80 37 OT100F8D
125 125 90 45 OT125F8D
Includes: 2 x OT switches OHRS3 direct handle Multi pole adaptor 2 x OTPS 4th pole
ot16 - 40F6
oH_
oHr 3
oXP6X_
otP_32_
owP5D1
oXs6X_
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
13.7.1. Load Break Switches
Front operated load break switches, base and Din rail mounting
Front operated load break switches, panel mount
optional handles for front operated panel mount switches
order codes - ot16...125F, 3 pole switch only. Handle and shaft to be ordered separately
order codes - ot16...100F, 3 pole switch only. Handle ordered separately
order codes - ot125...160 kits, 3 pole switch larger pistol handle (65mm)
order codes - snap-on mounting, door drilling 22.5mm Padlockable with max. 3 padlocks, suitable for ot16...32et, iP65, neMA 1, 3r, 12.
order codes - screw mounting Padlockable with max. 3 padlocks, suitable for ot16...32et, iP65, hold distance both 36mm and 48mm, neMA 1, 3r, 12.
ith encl Ac22A415V [A]
Ac23A415V [A]
415V [A] code
25 16 16 7.5 ot16F3
32 25 20 9 ot25F3
40 40 23 11 OT40F3
63 63 45 22 ot63F3
80 80 75 30 OT80F3
115 100 80 37 ot100F3
125 125 90 45 ot125F3
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
25 16 16 7.5 OT16FT3
32 25 20 9 ot25Ft3
40 40 23 11 ot40Ft3
63 63 45 22 OT63FT3
80 80 75 30 ot80Ft3
115 100 80 37 OT100FT3
ith encl Ac22A 415V [A] Ac23A 415V [A] 415V [A] code
115 100 80 37 ot125A3
125 125 90 45 OT160E3
Includes: OXP6X210 extension shaft with 6mm diameter and 210mm in length OHB65J6 IP65 selector handle for 6mm diameter shaft
See dimension drawings. Selector type handles. Indication I-O and ON-OFF. No separate shaft needed.
colour code
Black OHBS2PJ
Yellow-Red OHYS2PJ
colour code
Black OHBS2RJ
Yellow-Red OHYS2RJ
ot16 - 40F3
ot 160A3
ot63 - 80F3
ot 16...32Ft3
ot 100...Ft3
ot100 - 125F3
ot 45...63Ft3
oH_2PJ
13-583
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.2. Switch Disconnectors
Front operated switch disconnectors, with pistol handle
order codes - ot160...800e, 3 pole switch with iP65 pistol handle and outboard shaft
order codes - ot160...800e, 3 pole switch with iP65 pistol handle and inboard shaft
Including a black ON-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF position and with door interlock in the ON-position. The shaft is adjustable for a range of installation depths.
ith open [A] Ac22A 415V [A] Ac23A 415V [A] code
200 200 160 OT160EV03P
200 200 200 ot200e03P
250 250 250 ot250e03P
315 315 315 OT315E03P
400 400 400 ot400e03P
630 630 630 OT630E03P
800 800 800 OT800E03P
ith open [A] Ac22A 415V [A] Ac23A 415V [A] code
200 200 160 OT160EV12P
200 200 200 OT200E12P
250 250 250 OT250E12P
315 315 315 OT315E12P
400 400 400 OT400E12P
630 630 630 OT630E12P
800 800 800 OT800E12P
ot315 - 400e04
ot630 - 800e03
ot630 - 800e04
ot200 - 250e03
ot315 - 400e03
ot200 - 250e04
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
13.7.2. Switch Disconnectors
Front operated switch disconnectorsorder codes - ot1000...2500, 3 pole switch with iP65 pistol handle and outboard shaft
order codes - ot1000...2500, 3 pole switch with iP65 pistol handle and inboard shaft
ith open [A] Ac22A 415V [A] Ac23A 415V [A] code
1000 1000 800 OT1000E03P
1250 1250 1000 OT1250E03P
1600 1600 1000 OT1600E03P
1600 1600 1000 OT1600E03W8P (1)
2000 2000 - OT2000E03P
2500 2500 - OT2500E03P
(1) With extended phase distance 185mm
ith open [A] Ac22A 415V [A] Ac23A 415V [A] code
1000 1000 800 OT1000E12P
1250 1250 1000 OT1250E12P
1600 1600 1000 OT1600E12P
2000 2000 - OT2000E12P
2500 2500 - OT2500E12P
order codes - oetL3150 switch with iP65 metallic handle
number of poles ith open [A] Ac22A 415V [A] Ac23A 415V [A] code
3 3150 3150 1600 OETL3150K3 (3)
3 3150 3150 1600 OETL3150K185 (2)(3)
4 3150 3150 1600 OETL3150K4 (3
3 3150 3150 1600 OETL3150KV12
4 3150 3150 1600 OETL3150KV22
(2) With extended phase distance: - OETL3150K185:185mm(3) The busbar connections for different busbar arrangements have to be ordered separately.
Handles and bolt kits included as standard
suitable for switches included shaft included handle included terminal bolts
OT1000...1250_P OXP12X280 OHB274J12 M12x50
OT1600_P OXP12X280 OHB274J12 M12x60
OT2000...2500_P OXP12X280 OHB274J12 M12x60
OETL3150 OXP12X325 YASDA7 M12x60
13-585
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.3. Change Over Switches
ot 16 F3c
ot 45...63 F3c
ot 125 F3c
order codes - ot 16… 125 Kits - 3 pole change/over with direct handle
number of pieces Ac22A 415V [A] Ac23A 415V [A] 415V [kw] code
including the oHrs3 direct handle and 2x ot switches complete with change over mech.
3 16 16 7.5 OT16F3CD
3 25 20 9 OT25F3CD
3 40 23 11 OT402F3CD
3 63 45 22 OT635F3CD
3 80 75 37 OT803F3CD
3 100 80 37 OT100F3CD
3 125 90 45 OT125F3CD
4 pole change/over with direct handleincluding the oHrs3 direct handle and 2x ot switches complete with change over mech.
number of poles Ac21A/Ac22A 415V [A] Ac23A 415V [A] 415V [kw] code
4 16 16 7.5 OT16F4CD
4 25 20 9 OT25F4CD
4 40 23 11 OT402F4CD
4 63 45 22 OT63F4CD
4 80 75 37 OT80F4CD
4 100 80 37 OT100F4CD
4 125 90 45 OT125F4CD
ot 16… 125 Kits - 3 pole change/over with pistol handleIncluding handle OHB45J6E311, IP 65 pistol handle, shaft OXP6X265, length 265 mm and 2x OT switches complete with change over mech.
3 16 16 7.5 OT16F3CP
3 25 20 9 OT25F3CP
3 40 23 11 OT402F3CP
3 63 45 22 OT63F3CP
3 80 75 37 OT80F3CP
3 100 80 37 OT100F3CP
3 125 90 45 OT125F3CP
4 pole change/over with pistol handleIncluding handle OHB45J6E311, IP 65 pistol handle, shaft OXP6X265, length 265 mm and 2x OT switches complete with change over mech.
3 16 16 7.5 OT16F4CP
3 25 20 9 OT25F4CP
3 40 23 11 OT402F4CP
3 63 45 22 OT63F4CP
3 80 75 37 OT80F4CP
3 100 80 37 OT100F4CP
3 125 90 45 OT125F4CP
Front operated load break switches, base and Din-rail mounting
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
13.7.3. Change Over Switches
ot2000...2500e03cP
ot630...800e03cP
ot 1000... 1250e03cP
ot 1600e03cP
oA_G_
oA_G_
oA_G_, ots_s
oetLZXc 19...22
order codes - 3 Pole
order codes
order codes - terminal shrouds
rated current/ rated power Ac-21A / Ac-22A up to 415V i/[A]
Ac23A 400V-415V i/[A], P/[kw] code
200 200/110 OT 200E03CP
250 250/132 OT 250E03CP
315 315/160 OT 315E03CP
500 500/200 OT 400E03CP
630 630/315 OT 630E03CP
800 720/355 OT 800E03CP
1000 800/400 OT 1000E03CP
1250 800/400 OT 1250E03CP
1600 800/400 OT 1600E03CP
2000 OT 2000E03CP
2500 OT 2500E03CP
suitable for switches contact function code
OT16...125F_C 1NO oA1G10
1NC oA3G01
OT_200...2500E_C 1NO oA1G10
1NC oA3G01
OT63...125F3C 1NO+1NC OA2G11
suitable for switches number of poles contact function code
snap-on mounting, transparent plasticiP20. the full shrouding of a 3-pole change-over switch is achieved with four 3-pole shrouds
OT16...40 3 OTS40T3
OT63...80 3 OTS63T3
OT100...125 3 OTS125T3
snap-on mounting, grey plastic (3 in a pack)suitable for the upper switch. A kit includes three (four) shrouds which can be used on either side of the switch. transparent shrouds for ot_200...2500 available on request, please replace the letter “G” with “t”.
OT200…250E_C 3 Long type OTS250G1L3
3 Short type OTS250G1S3
OT315…400E_C 3 Long type OTS400G1L3
3 Short type OTS400G1S3
OT630…800E_C 3 Long type OTS800G1L3
3 Short type OTS800G1S3
OT1000…1600E_C 3 Long type OTS1600G1L3
3 Short type OTS1600G1S3
OT2000…2500E_C 3 Long type OTS2500G1L3
3 Short type OTS2500G1S3
For 4 pole switches purchase 3 packs
Front operated load break switches, base and Din-rail mounting
Accessories
change over switches, 3-pole, i-o-ii -indicationIncluding a black plastic IP65 I - 0 - II pistol type handle, see the table below, shaft and bolt set for the cable connection. Handle padlockable in the 0-position, door interlock in the I- and II-positions and when padlocked.
Auxiliary contact blocksMounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Simultaneous action with the main contacts, IP20.
13-587
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.4. Optional Handles
order codes
order codes
order codes
optional Handles for front operated switches
optional Handles for front operated, base and Din-rail mounted switches
colour code
Handle knobs, mounting directly to the switch, no shaft needed.suitable for ot16...125F3/F4, ot16...32F6/F8
Red OHBS2PJ
Black OHYS2PJ
suitable for 6 and 8 pole switches ot45...125F6 and _F8
Red OHBS9
Black OHRS9
suitable for ot160
Black YAST1
colour code
selector type handlesindication i-o and on-oFF, shaft (diameter 6mm) has to be ordered separately, door drilling 22.5mm.iP54 handles, padlockable with one padlock with bail diameter 5...6.3mm, door interlock in on- position.suitable for ot16...125F, neMA 1
Black OHBS3AH1
Yellow-Red OHYS3AH1
iP65 handles, padlockable with max. 3 padlocks, with bail diameter 5...8mm, door interlock in on- position, defeatable.suitable for ot16...125F, neMA 1, 3r, 12
Black OHBS2AJ
Yellow-Red OHYS2AJ
Pistol type handles, plastic iP65, neMA 1, 3r, 12OH_handles: IP65, NEMA 1, 3R, 12, padlockable, with 3 padlocks in OFF-position, door interlock in ON-position (defeatable1) to allow authorised personnel access for inspection.The shaft has to be ordered separately. Screw fixing from back side of the handle. Now screws on the front ensures double insulation.
colour Handle length [mm] suitable for switches code
For shaft diameter 6mm, indication i-0, on-oFF
Black 45 OT16...125F OHB45J6
Yellow-red 45 OT16...125F OHY45J6
For shaft diameter 6mm, indication i-0, on-oFF
Black 65 OT160...250 oHb65J6
Yellow-red 65 OT160...250 OHY65J6
Black 80 OT160...250 OHB80J6
Yellow-red 80 OT160...250 OHY80J6
For shaft diameter 6mm, indication test-oFF-on/test-0-i
Black 65 OT200...250 OHB65J6T
Yellow-red 65 OT200...250 OHY65J6T
For shaft diameter 12mm, indication i-0, on-oFF
Black 95 OT315...400 OHB95J12
Yellow-red 95 OT315...400 OHY95J12
Black 125 OT630...800 OHB125J12
Yellow-red 125 OT630...800 OHY125J12
Black 274 OT1000...2500 OHB274J12
Yellow-red 274 OT1000...2500 OHY274J12
oHb 9
oH_ 3_
YAst 1
oH_ 2_
oHb200J12P
oHr 3
oH_
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
13.7.4. Optional Handles
optional Handles
order codes
order codes
order codes
Metallic handles, iP65, neMA 1, 3r, 4, 4x, 12, padlockable with 3 padlocks in oFF-position, door interlock on-positionFor shaft diameter 12mm, indication ON-OFF
Handle support for direct mountingHandle support for direct mounting on the OT160 switch mechanism for OH_65, 80 handles.
stainless steel handlesStainless steel handles, indication I-O/ON-OFF, padlockable with 3 padlocks in the OFF-position, door interlock in the ON- position, IP66 (NEMA 4X)
colour Handle length [mm] suitable for switches code
Black 320 OT1000...2500 YAsDA28
Black 220 OT3150 YASDA8
colour Height from the bottom of the switch code
Black 83mm OHZX5
colour Handle length [mm] code
For shaft diameter 6mm
Grey 65 OHM65L6
For shaft diameter 12mm
Grey 125 OHM125L12
Grey 175 OHM175L12
Grey 275 OHM275L12
Grey 2x200 OHM200L12P
YAsDA_
oHM125L12
13-589
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.5. Extended Shafts
extended shaftsorder codes
order codes - step shaft (step shaft diameter 6-12mm)
order codes - shaft extension socket (For extending the shaft of combination attachment)
order codes - Adapter for extension socket (the adapter can be placed inside the extension socket)
shaft length [mm] Handle length [mm] suitable for switches code
shaft diameter 6mm, for selector type shafts
85 OT16...125F OXS6X85
120 OT16...125F OXS6X120
180 OT16...125F OXS6X180
250 OT16...125F OXS6X250
330 OT16...125F OXS6X330
shaft diameter 6mm, for pistol type handles
150 OT16...125F OXP6X150
265 OT16...125F OXP6X265
430 OT16...125F OXP6X430
shaft diameter 6mm
210 189...254 OT160...250 OXP6X210
290 269...334 OT160...250 oXP6X290
360 339...404 OT160...250 OXP6X360
430 409...474 OT160...250 oXP6X430
shaft diameter 12mm
250 224...304 OT315...400 OXP12X250
325 299...379 OT315...400 OXP12X325
395 369...449 OT315...400 OXP12X395
465 439...519 OT315...400 OXP12X465
535 509...589 OT315...400 OXP12X535
shaft diameter 12mm
325 305...415 OT630...800 OXP12X325
330...400 OT1000...2500
340...535 OETL3150
395 375...485 OT630...800 OXP12X395
400...470 OT1000...2500
410...605 OETL3150
465 445...555 OT630...800 OXP12X465
470...540 OT1000...2500
480...675 OETL3150
535 515...625 OT630...800 OXP12X535
540...610 OT1000...2500
550...745 OETL3150
shaft length [mm] code
190 OXP612X190
shaft length [mm] code
suitable for shaft with diameter [mm]
5...6 OESAZX167
12 OETLZX95
shaft length [mm] code
suitable for shaft with diameter [mm]
5...6 OETLZK19
oXP12
oXP612X190
oetLZX 95, oesAZX 167
oetL ZK 19 (x = 6 mm)
oXsX_
oXP6X_
oXP6X_
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Description suitable for switches code
1NC 21(31) 22(32)
OT16...125F oA1G01 (1)
1NO 13(43) 14(44)
OT16...125F oA1G10 (2)
1NO + 1NC
13 21 14 22
OT16...125FOT80
oA2G11 (3) (6)OA2L11 (3) (6)
Discount code L11
13.7.6. Auxiliary Contacts
Auxiliary contact blocks and accessories
Auxiliary contact blocks for ot 125A and ot 160e
order codes
order codes
order codes
order codes
Auxiliary contact blocks for ot16...125FSnap-on mounting to the switch, IP20, Ith = 16A, cable cross section max. 2 x 2.5 mm2.Performance data Ue / Ie (AC15): 230V/6A, 400V/4A, 415V/4A, 690V/2A. Early-break types (OA1G10)
Mountable on top of switch. Wire cross section 0.5 mm2...2 x 2.5 mm2. Insulation voltage Ui 690V. Thermal current Ith=10A. Mounting on the adapter OEZNP1 (has to be ordered separately, see below), max. 6 aux. blocks. Early break type.Performance data Ue / Ie (AC12): 120V/8A, 240V/6A, 400V/4A, 415V/4A, 480V/3A, 500V/3A, 690V/2A,Performance data Ue / Ie (DC12): 125V/1.1A, 250V/0.55A, 440V/0.31A, 500V/0.27A, 600V/0.2A
Adapter for auxiliary contact blocks oA2G11Auxiliary contact blocks, OA2G11, max. two blocks/side, have to be ordered separately, see auxiliary contacts for OT16...125 switches. Mountable on either side of the switch.
Adapter for auxiliary contact blocks obeA_Mountable on top of the switch.
Function Protection degree code (2)
1NO IP20 obeA10
1NC IP20 obeA01
suitable for switches code
OT160E OAZX1
suitable for switches number of poles code
OT 125AOT 160E
3 and 4 OEZNP1
(1) Mountable on the left side of the switch, max. 2 pcs(2) Mountable on the right side of the switch, max. 2 pcs(3) For base-mounted switches only. Max. 4NO + 4NC, (OT16...32E: max. 2NO + 2NC) (83) (43) (53) 13 21 (61) (31) (71) (84) (44) (54) 14 22 (62) (32) (72)(6) Not mountable on the same side as the fourth pole.
oA2G11 oA1G_ oA2L11
oeZnP 1 obeA 10, obeA 01
Auxiliary contacts - mounted on both sides of the switch.
oA2G11, oAZX1
13-591
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.6. Auxiliary Contacts
Auxiliary contact blocks and accessories
order codes
order codes
Auxiliary contact blocks for ot 200...2500Mounting on the left side of the switch: Max. 8 auxiliary contact blocks with the OEA28 moduleMounting under the mechanism cover: OT200-250: Max. 4 test contacts or 2 test contacts + 2 test indication contacts. OT315-800: Max. 4 test contacts + 4 test indication contacts. OT1000-2500: Max 4 test indication contacts + 8 test contacts. The test contacts can be used as standard auxiliary contacts as well.
Auxiliary contact blocks for oetL 3150Wire cross section 0.5 mm2...2 x 2.5 mm2. Insulation voltage Ui 690 V. Thermal current Ith = 10 A. Protection degree IP 20. Early break type.Performance data 3) Ue /Ie (AC12):120V/8A, 240V/6A, 400V/4A, 415V/4A, 480V/3A, 500V/3A, 690V/2A, Ue /Ie (DC12): 125V/1.1A, 250V/0.55A, 440V/0.31A, 500V/0.27A, 600V/0.2A.
Function protection degree code
1NO IP20 oA1G10
1NC IP20 oA3G01
Module for auxiliary contacts
Screw mounting to the left side of the switch OEA28
Auxiliary contacts (2) suitable for switches code
1NO+1NC OETL 3150 OZXK1
2NO+2NC OETL 3150 OZXK2
4NO+4NC OETL 3150 OZXK3
2NO OETL 3150 OXZK4
4NO OETL 3150 OZXK5
8NO OETL 3150 OZXK6
oA_G_
oeA28
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
13.7.7. Fourth Poles & Neutral Links
Fourth Poles
neutral Links
order codes
order codes
suitable for switches code
simultaneous function with the main contacts
OT16...40F3 OTPS40FPN1
OT63...80F3 OTPS80FP
OT100...125F3 OTP125FP
OT125A3...160E OTPS160EP
OT16...40FT3 OTPS40FDNI
OT63...80FT3 OTPS80FD
OT100FT3 OTPS125FD
Late-break and early-make
OT16...40FT3 OTPL40FD
OT63...80FT3 OTPL80FD
OT100.125FT3 OTPL125FD
Mountable on side of the 3 pole switches, ot160e3, ot200...2500
OT200...250 OTZ250E
OT315...400 OTZ400E
OT630...800 OTZ800E
OT1000...1250 OTZ1250E
OT1600 OTZ1600E
OT2000...2500 OTZ2500E
suitable for switches ith [A] code
OT200...250 250 OXN250
OT315...400 400 OXN400
OT630...800 800 OXN800T
OT1000...1250 1250 OXN1250TotP_ 125_
otPs160_ P
oXn250
otP_ 40_
otP_ 80_
otP_ 80_
13-593
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.8. Terminal Shrouds
terminal shrouds
Phase separators
order codes - snap-on mounting, transparent
order codes - Grey plastic plate. snap-on mounting.
order codes - snap-on mounting, grey plastic
suitable for switches code
For 3 pole switches
OT16...40F3, -FT3 ots40t3
OT63...80F3, -FT3 OTS63T3
OT100...125F3, FT3 OTS125T3
OT160E3 OTS160T3
For 1 to 4 pole switches, shroud for single pole and for fourth pole
OTP_40F_ OTS40T1
OTP_80F_ OTS63T1
OTP_125F OTS125T1
suitable for switches Description code
For 3 pole switches (3 in a pack)
OT200...250 Long Type OTS250G1L3
OT200...250 Short Type OTS250G1S3
OT315...400 Long Type OTS400G1L3
OT315...400 Short Type OTS400G1S3
OT630...800 Long Type OTS800G1L3
OT630...800 Short Type OTS800G1S3
OT1000...1600 Long Type OTS1600G1L3
OT1000...1600 Short Type OTS1600G1S3
OT2000...2500 Long Type OTS2500G1L3
OT2000...2500 Short Type OTS2500G1S3
Note: For 4 pole switches purchase 3 packets.IP 3X. Transparent shrouds available on request.
suitable for switches Description code
OT200...800 27.50 ISDA054970R1
OT630...800E 3 and 4 pole Long type (OTB800/6) OTB800/6
ots_t3 ots 160t3
ots_t1 ots125t1
otb800/6
ots_s_ ots_L_
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.7. Switches Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
13.7.9. Conversion Kits
conversion Kits for front operated switch combinations
6 and 8 pole switch mechanismParallel attachment for connecting two 3 or 4-pole switches. The switches work simultaneously mounting directly on the top of two switch-disconnectors, snap-on mounting. The switch size is printed on stickers for the different switch sizes. The fourth pole or auxiliary contacts can be mounted on the outer side of the combination.
change over switch mechanismTwo switches connected with a mechanism operation into I-O-II positions. Two 3 or 4 pole switches needed.
by-pass switch mechanismA combination of two switches in parallel with a third switch for change-over operation to by-pass, for example, a breaker for maintenance. The by-pass attachment can be used together with another combination attachment. Three 3 or 4-pole switches needed.
Mechanical interlock mechanismPrevents one switch from closing to ON-position, if the other is not in OFF-position. When mounted upside down, prevents one switch from opening to OFF-position, if the other is not in ON-position. (UPS-usage, make-before-break).
order codes
order codes
order codes
order codes
suitable for switches shaft distance [mm] code
OT16-40F OWP6D40
OT63-80F OWP6D80
OT100-125F OWP6D125
Attachment levers provided with holes, enabling different shaft distances. The combination switches can be mounted either horizontally or vertically. two 3 or 4 pole switches required.
OT160 45+(0 - 11)x15 OESAZW2
OT200-250 45+(0 - 13)x15
OT315-800 60+(0 - 19)x20 OETLZW9
suitable for switches shaft distance [mm] code
OT200-250 210+(0-18)x20 OTZW25
OT315-400 210+(0-11)x20 OETLZW11
OT630-800 210+(0-20)x20 OETLZW12
suitable for switches shaft distance [mm] code
OT16-125 Between 1 and 2: 90+(0-6)x15 Between 1 and 3: 90+(0-10)x15
OTZW17
OT200-250 Between 1 and 2: Between 1 and 3: 250+(0-9)x20
OTZW26
OT315-800 Between 1 and 2: 210+(0-18)x20 Between 1 and 3: 250+(0-18)x20
OETLZW13
suitable for switches shaft distance [mm] code
two 3 pole switches needed
OT16-125 100 OTZW24
two 4 pole switches needed
OT160-250 190 OTZW10
two 3 or 4 pole switches needed
OT315-400 250 OETLZW14
OT315-800 300 OETLZW3
OT315-2500 & OETL3150 500 OETLZW15
Note: See the table of handles and shafts included in the conversion kits on the next page.
otZw25, oetLZw11
oetLZw 12
otZw 17
otZw24, 10oetLZw 14, 3, 15
otZw26, oetLZw13
owP5D1
owP6D1
oesA Zw 2, oetLZw9
13-595
13.7. Switches Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
13.7.9. Conversion Kits
shafts and handles for conversion kitsorder codes
to be ordered separately included in conversion kit delivery
the standard handleor shaft of one of the combined switches can be used
code
shaft Handle shaft Handle shaft Handle
6 and 8 pole switches
x (shaft dia 6mm)
OHBS1A_ - - - - OWP6D40
x (shaft dia 6mm)
OHBS1A_ - - - - OWP6D80
x (shaft dia 6mm)
OHBS1A_ - - - - OWP6D125
x (shaft dia 6mm)
OHBS1A_ - - - - OWP6D40
x (shaft dia 6mm)
OHB45J6 - - - - OWP6D80
x (shaft dia 6mm)
OHB45J6 - - - - OWP6D125
- - x (2 pcs) OHB145J12 - - OESAZW2
- - - - x x OETLZW9 for OT
- YASDA7 or 8 - - x - OETLZW9 for OETL
change-over switches
- x (2 pcs) OHB80J6E011 - - OESAZW1
- - x (2 pcs) OHB80J6E011 - - OTZW25
- - x (2 pcs) OHB145J12E011 - - OETLZW11
- x (2 pcs) YASDA21 (metallic) - - OETLZW12
by-pass switches
- - x (3 pcs) OHB80J6E011 OTZW17
- - x (3 pcs) OHB95J12E011 - - OTZW26
- - x (3 pcs) YASDA 6 - - OETLZW13
Mechanical interlock
- - - - x x OTZW24
- - - - x x OTZW10
- - - - x x OETLZW14
- - - - x x OETLZW3
- - - - x x OETLZW15
change-over switches
change-over and by-Pass switches
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
13
Discount code L11
13.8. Fuse Switch Disconnectors
3 Pole
XLP 000 100 AmpXLP 00 160 AmpXLP 1 250 AmpXLP 2 400 AmpXLP 3 630 Amp
Properties of the easyLine XLP:
• Compact XLP 000• Typetested according to EN IEC 60947- 3• Fullfills BGV A2• Easy to recycle / EN ISO 14001 standards• Quick- make operation device• Integrated IP 20 cable termination• IP 30 degree of protection from the front• Replacement compatible to similar types in the market• Voltage measuring from the front• V- 0 plastic materials
XLP Fuse switch Disconnectors
3 Pole
busbar adapters for XLP 00 and XLP 160 mm Busbar systemDesigned for 60 mm busbar distanceCu/ Al 5/ 10x10,12, 20, 25 or 30 mm.3 pieces of distance shoes for 5 mm busbars are included with the adapter.Adapter 60 mm for cable connection below : A 60 - Down
Description units XLP 000 XLP 00 XLP 1 XLP 2 XLP 3
000 00 0 1 use size acc. to DIN 43620 /
EC / EN 60269- 2- 1 Max. W=21 mm
Rated operational voltage Ue V 400 500 690 400 500 690 400 500 690 400 500 690
Rated operational current Ie A 80 100 50 125 160 125 250 200 400 315
Thermal current w/ fuse link lth A 100 160 250 400
Rated insulation voltage Ui V 690 1000 1000 1000
Rated impulse withstand voltage Uimp
V 6000 8000 8000 8000
Fuse protected short circuit making kArms 50 50 50 50
Rated making and breaking capacity :
AC23B AC22B AC21B
AC23B AC22B AC21B
AC23B AC22B AC21B
AC23B AC22B AC21B
Rated frequency Hz 50/60 50/60 50/60 50/60
Power loss at Ith without fuse link/ phase
W 1.4 3.5 7.5 13
Electrical durability 300 200 200 200
Mechanical durability 1700 1400 1400 800
Open IP20 IP20 IP20 IP20 Degree of protection from the front
Closed IP30 IP30 IP30 IP30 acc. to IEC / EN 60529 Closed
Advantages of the easyLine XLP:
• Easy to install• Easy to snap on DIN rails• Easy to operate• Easy to understand• Modern cable terminals• Modern and functional design• Additional arc protection shroud in front cover-increased personal safety• Wide range of modern cable clamps and accessories• Electronice fuse monitoring• Wide range of busbar adapters
13-597
13.8. Fuse Switch Disconnectors Stock Status:Normally stocked /Not normally stocked
13
Discount code L11
XLP Fuse switch Disconnectors
item Description XLP 000 code
XLP 000100 A with Bolts XLP 000
XLP 00160 A with bolts XLP 00
XLP 00 with 60 mm busbar centres160 A incl. A60/60 Adapter incl. 3 BC, cable down XLP 00-A60/60
XLP 1250 A with bolts XLP 1
XLP 1 with 60 mm busbar centres250 A XLP 1-A60/85
XLP 2400 A with bolts XLP 2
XLP 3630 A with bolts XLP 3
order codes
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distribution13.8. Fuse Switch Disconnectors Stock Status:
Normally stocked /Not normally stocked
13
Discount code L11
Fuse bases
terminal Accessories
number of poles terminal width [mm] [pcs] in [A] [kg] code
terminal width 15 mm. Full protection iP 20
1 15 160 OFAX 00 S1
3 15 160 OFAX 00 S3
terminal width 15 mm. open with phase barriers iP 00
1 15 160 OFAX 00 P1
3 15 160 OFAX 00 P3
Fuse bases for fuse size 1, ui = 1000 VFull protection iP 20
1 25 250 OFAX 1 S1
3 25 250 OFAX 1 S3
open with phase barriers iP 00
1 25 250 OFAX 1 P1
3 25 250 OFAX 1 P3
Fuse bases for fuse size 2, ui = 1000 VFull protection iP 20
1 30 400 OFAX 2 S1
3 30 400 OFAX 2 S3
open with phase barriers iP 00
1 30 400 OFAX 2 P1
3 30 400 OFAX 2 P3
Fuse bases for fuse size 3, ui = 690 VFull protection iP 20
1 40 630 OFAX3S1
3 40 630 OFAX3S3
open with phase barriers iP 00
1 40 630 OFAX3P1
3 40 630 OFAX3P3
For fuse base sizes terminal width [mm] remarks code
terminal width 15 mm. Full protection iP 20
00_L 20 25...120 mm2 Al/Cu OZXB 2
1, 2, 3 25,30,40 70...185 mm2Al/Cu OZXB 3
1, 2, 3 25,30,40 2 x (70...185) mm2 Al/Cu OZXB 4
1, 2, 3 25,30,40 120...300 mm2 Al/Cu OZXB 5
order codes - Fuse bases for fuse size 00, ui = 1000 V
order codes
13-599
13.8. Fuse Switch Disconnectors Stock Status:Normally stocked /Not normally stocked
13
Discount code L10
number of poles terminal width [mm] [pcs] in [A] [kg] code
000
2 3,9 OFAF000H24 1,5 OFAF000H46 1,6 OFAF000H610 1,1 OFAF000H1016 1,8 OFAF000H1620 2,4 OFAF000H2025 2,4 OFAF000H2532 2,7 OFAF000H3235 3,0 OFAF000H3540 3,4 OFAF000H4050 3,9 oFAF000H5063 4,7 OFAF000H6380 5,7 OFAF000H80100 6,7 OFAF000H100
00125 8,4 oFAF00H125160 10,6 OFAF00H160
0
100 8,7 OFAF0H100125 11,0 OFAF0H125160 11,7 OFAF0H160200 15,0 oFAF0H200
1
16 2,5 OFAF1H1620 3,5 OFAF1H2025 3,3 OFAF1H2532 3,2 OFAF1H3235 3,5 OFAF1H3540 4,2 OFAF1H4050 5,1 OFAF1H5063 6,2 OFAF1H6380 7,1 OFAF1H80100 8,7 OFAF1H100125 11,0 OFAF1H125160 11,7 oFAF1H160200 14,5 oFAF1H200224 15,9 OFAF1H224
2
80 8,6 OFAF2H80100 10,6 OFAF2H100125 11,9 OFAF2H125160 14,0 OFAF2H160200 15,4 OFAF2H200224 19,1 OFAF2H224250 22,5 OFAF2H250300 24,0 OFAF2H300315 26,2 OFAF2H315355 27,5 OFAF2H355400 30,2 OFAF2H400
3
250 17,9 OFAF3H250300 20 OFAF3H300315 22,4 OFAF3H315355 23,5 OFAF3H355400 30,1 OFAF3H400425 33,0 OFAF3H425450 36 OFAF3H450500 44,0 OFAF3H500630 47,5 OFAF3H630800 56,9 OFAF3H800
order codes - Hrc Fuse links, universal fuses, gG, up to 500V.
order code - Fuse replacement handle
Fuse Line Hrc Fuse links, type gG, 500V
For fuse sizes Description code
000, 00, 1, 2, 3 Compact OFAE 504
690 V gG and aM fuses from 2 A up to 1250 A available on indent.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
13. Power Distributionstock status:normally stocked /Not normally stocked
13
Discount code c14
13.9. Vacuum Contactors
Description 200A 1500V 400A 1500V 600A 1500V
order code (cat 3 Pole 1.5KV) cV 77u031615-* cV 77u034A15-* cV77u036A15-*
Auxiliary contacts - standard 2 NO & 2 NC
insulating and operational Voltage
1500V
rated oper. Ac1 200A 400A 600A
rated oper. Ac3 500 HP 370KW-1500V 850 HP 650KW-1500V 1200 HP 900KW-1500V
rated oper. Ac4 315 HP -235KW-1500V 650 HP 570KW-1500V 950 HP 700KW-1500V
rated Frequency 50-400Hz
Making current 2000A 4000A 6000A
breaking current 1600A 3200A 4800A
short time current 1 sec.10 sec. 5000A 7000A 9000A
1600A 3200A 4800A
Mechanical Life 1.2 x 106 0.75 x 106
electrical Life Ac3 Duty 1 x 106 0.5 x 106
switching Frequency 600/Hr (1 every 6 sec) 300/Hr (1 every 12 sec)
operating range -15% +10% - at Range Voltage
-15% +10% - over Range Voltage
inrush Power VA 1200VA 20ms Duration 1100VA 120ms Duration 1600VA 120ms Duration
Holding Power 12VA 10-12VA 10-12.5VA
recommended cPt 400VA Machine Tool Transformer 5% Regulation at 20% pf
500VA Machine Tool Transformer 5% Regulation at 20% pf
Mounting installation All Planes (Contactor only)
Ambient operating temp. -40°C +50°C
weight 5.9Kg 11.8kg 12.7kg
Price (ex Gst) $2800.00 $3300.00 $4700.00
Price (incl Gst) $3080.00 $3630.00 $5170.00
Additional option Add AK1 2NO & 2NC aux contact
International Ratings for World Wide Applications UL Listed CSA certified 600V/ 660V/ 1000V/ 1500V
Joslyn Clark’s unique Compact AC Vacuum Contactors & Starters are ideal for tough industrial applications. The compact design provides flexibility for retrofitting to all existing air break contactors, thus enabling an existing application to continue with maintenance cost and down time eliminated.
• Suitable for worldwide applications and for use with all types of motors including high efficiency IEC motors• IEC HP/KW rated 200A, 400A or 600A and 660V/1000V/ 1500VAC - UL508 Listed CSA22.2 certified IEC 947-4-1• Purpose rated 160A, 400A or 600A and 660V/ 1000V/ 1500V AC - UL508 Listed CSA22.2 certified IEC 947-4-1
• Front accessible • Compact • Fully phase insulated • Long Mechanical Life • Mounts in any plane • Lightweight• Quiet• Rugged• Long electrical life
usAVAc® compact international Ac Vacuum contactor
For your information:For QLD Customers only
13-601
13.9. Vacuum Contactors Stock Status:Normally stocked /Not normally stocked
13
Discount code c14
order code (cat no. 3 Pole 3.6KV)
320A 600A 1000AVc77u03536 Vc77u03636 sVc77u031036
rated insulating & operational Voltage
3600V
rated operational current 320A 600A 1000Arated Frequency 50/400HzMaking current 3200A 6000A 6000Abreaking current 3200A 6000A 6000Ashort time current 1 sec. 7000A 9000A 11000A2 sec. 5000A 7000A 9000AMechanical Life 2 x 106electrical Life at rated //current - Ac3 Duty
1 x 106
switching Frequency 600/hr every 6 secondsrated control Voltage 120/240V 50/400HzAllowable Fluctuation +10% of rated, -25% voltageclosing Power VA/ Duration 950VA/17MS 1900VA/17MS 2850VA/17MSHolding Power 9VA 18VA 27VArecommended control transformer
when required 250VA when required 500VA when required 750VA
installation All Planes (Contactor only)Ambient operating temp. -40°C + 57°Cweight 5.45kg 11kg 16.36kgDimensions 225 x 189 x 200mm 450 x 189 x 200mm 676 x 189 x 200mm
order code (cat no. 3 Pole 3.6KV) 300A
cV77u033A12
insulating and operational Voltage 1.14kV
rated impulse withstanding voltage 8kV
rated operating current utilization category Ac1 AC1 at 40C = 330 AAC1 at 60C = 300A
rated Power for Ac loads (resistance heating) P.F. = 0.95 (at 60c) 230V-73kW, 400V-197kW, 500V-246kW, 690V-340kW, 1000V-492kW
rated Frequency 50-60Hz
Making current 3000A
breaking current 2400A
short time current 1 sec. 6kA
10 sec. 2.4kA
electrical Life Ac3 Duty 1 million
switching Frequency 600/hr (every 6 seconds)
operating range -30% +25% at Range Voltage
closing Power VA 1680VA < 100ms Duration
Holding Power VA 17VA
Auxiliary contacts - standard 2 NO & 2 NC
Application ratings All Planes (Contactor only)
Ambient operating temp. range -25°C + 60°C
As one of the most demanding industries for rugged duty, mining equipment requires reliable power switching and motor starting solutions to ensure dependable productivity in harsh environments.
Joslyn Clark vacuum contactors are recognised by the leading coal-mine machine builders for applications on long-wall mining equipment, continuous miners, conveyors, power centres and other related equipment. Joslyn Clark’s newest product, the rugged 300A, 1140V Vacuum Contactor, meets the specific power requirements of the mining industry and offers several other benefits such as a small footprint and front accessibility. It also features a long electrical life and the kind of durability and reliability you’ve come to expect from Joslyn Clark vacuum contactors.
The Joslyn Clark USAVAC low voltage vacuum contactors are ideal for applications from 200V to 3600V, and motor rating for 50 to 500Hp at 460 volts. Contactors are available open or enclosed in Type 1, 3R, 4 & 12 enclosures for non combination and reduced voltage applications.
The low voltage vacuum contactors incorporate many useful features to insure ease of maintenance, versatility, and reliability. A three phase contactor contains ten basic parts. The contactor can be assembled or dismantled without the use of any tools.
new 300A, 1140 Volt Heavy Duty Mining Vacuum contactor
usAVAc® - Low Voltage Ac Vacuum contactors
For your information:For QLD Customers only
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14.1.1.1. XXX14.1.1. XXX
Section Guide Overview Stock Status:Normally stocked /Not normally stocked
Discount Code C12
14
14. Motor Control & ProteCtion
SeCtion 14
14-603
Motor Control & ProteCtion
14. Motor Control & ProteCtion 14-60214.1. Variable Speed Drives 14-604
Selection Guide 14-60414.1.1. Micro Drives 14-60614.1.2. Fan & Pump 14-60814.1.3. Machinery 14-60914.1.4. General Purpose 14-61114.1.5. HVAC 14-61314.1.6. Water & Wastewater 14-61414.1.7. Industrial 14-61514.1.8. DC Drives 14-618
14.2. Motor Protection relays 14-62014.2.1. Motor Temperature Monitoring Relay 14-62014.2.2. The Vision Relay Range 14-62014.2.3. Retrofit/Replacement 14-622
14.3. Soft Starters 14-62414.3.1. Overview 14-62414.3.2. Compact Range up to 105A 14-62614.3.3. Efficient Range up to 370A 14-62714.3.4. Advanced range up to 1050A 14-628
14.4. Contactors 14-63014.4.1. 3-Pole AC Operated 14-63014.4.2. 3-Pole DC Operated 14-63014.4.3. 3-Pole AC/DC Operated 14-63114.4.4. 4-Pole AC/DC Operated 14-63314.4.5. A & AF Series Accessories 14-63514.4.6. AF 09…AF 38 Accessories 14-638
14.5. thermal overload relays 14-64014.6. Manual Motor Starters 14-64214.7. enclosed Starters 14-648
14.7.1. D.O.L. Starters 14-64814.7.2. YRA Star Delta Starters 14-64914.7.3. WRA Reversing Starters 14-649
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion
14
Selection Guide14.1. Variable Speed Drives
Hardware Features ACS55 ACS150 ACS310 ACS355 ACS550 ACH550 ACS800 ACS850 ACQ810
Sizes 0.18 to 2.2kW 0.37 to 4kW 0.37 to 22kW 0.37 to 22kW 0.75 to 160kW 0.75 to 355kW 0.55 to 5600 1.1 to 500 0.37 to 400
Accel / Decel times 0.1 to 30sec 0.1 to 1800sec 0.1 to 1800sec 0.1 to 1800sec 0.1 to 1800sec N/A 0.1 to 1800 sec 0.1 to 1800 sec 0.1 to 1800 sec
Supply Voltage ratings 115V, 200/240V 1 Phase 200/240V 1 Phase, 200/240V 3 Phase, 380/480V 3 Phase
200/240V 3 Phase, 380/480V 3 Phase
200/240V 1 Phase, 200/240V 3 Phase, 380/480V 3 Phase
200/240V 3 Phase, 380/480V 3 Phase
200/240V 3 Phase, 380/480V 3 Phase
380 to 690 380 to 500 380 to 480
Motor Control V/Hz only V/Hz only V/Hz only (linear, squared, user defined)
V/Hz, Sensorless Vector & Flux Vector
V/Hz, Sensorless Vector & Flux Vector
V/Hz, Sensorless Vector & Flux Vector
V/Hz & Direct Torque Control (exceeds Flux Vector
Performance)
V/Hz & Direct Torque Control (exceeds Flux Vector
Performance)
V/Hz & Direct Torque Control (exceeds Flux Vector
Performance)
overload torque 150% for 1 min 150% for 1 min 110% for 1 min 150% for 1 min180% for 2 sec
150% for 1 min180% for 2 sec
150% for 1 min180% for 2 sec
150% for 1 min, 200% for 10 sec
150% for 1 min, 200% for 10 sec
110% for 1 min
Dynamic Brake N/A Internal Chopper Standard N/A Internal Chopper Standard Internal Chopper through to 11kWOptional External Brake Chopper
N/A Standard up to 15 kW and then available as an option
Standard N/A
Analog inputs 1 x Configurable 0-10V, 0-20mA or Potentiometer Reference
1 x Configurable 0-10V, 0-20mA or Potentiometer Reference
2 x Non-Isolated Configurable +/- 0-10V, +/-0-20mA or Potentiometer Reference
2 x Configurable 0-10V, 0-20mA or Potentiometer
Reference
2 x Configurable 0-10V, 0-20mA or Potentiometer
Reference
2 x Configurable 0-10V, 0-20mA or Potentiometer
Reference
1 x 0-10V, (2) 0-20mA 2 x configurable as 0-10V or 0-20mA
2 x configurable as 0-10V or 0-20mA
Analog outputs N/A N/A 1 x Non-Isolated 0-20mA 1 x Non-Isolated 0-20mA 2 x Non-Isolated 0-20mA 2 x Non-Isolated 0-20mA 2 x 0-20mA 2 x 0-20mA 2 x 0-20mA
Communications N/A N/A RS232 & RS485 Modbus Standard Modbus, DeviceNet, Profibus, CANopen & Modbus TCP/IP,
Ethernet IP, SREA-01
RS485 Modbus Standard, DeviceNet, Profibus, CANopen & Modbus TCP/IP, Ethernet IP,
ControlNet, SREA-01, EtherCAT
RS485 Modbus, BACnet MS/TP, N2, FLN
Optional BACnet / IP Router, LONworks adapter
DeviceNet, Profibus-DP, Modbus-RTU, Ethernet/
IP, Modbus TCP, Profinet, LonWorks, CANopen, ControlNet SREA-01
DeviceNet, Profibus-DP, Modbus-RTU, Ethernet/
IP, Modbus TCP, CANopen, SREA-01
DeviceNet, Profibus-DP, Modbus-RTU, Ethernet/
IP, Modbus TCP, LonWorks, SREA-01
Digital inputs 3 x 12 to 24VDC Fixed Function – Start/Stop,
Reverse, Jog
5 x 12 to 24VDC All Programmable
Pulse Train (0 to 16kHz)
5 x 12 to 24VDC with internal or external power supply, PNP & NPN,
Pulse Train (0 to 10kHz)
5 x 12 to 24VDC All Programmable
Pulse Train (0 to 10kHz)
6 x 12 to 24VDC StandardAll Programmable
6 x 12 to 24VDCAll Programmable
7, 6 of which are freely programmable
6, freely programmable 6, 5 of which are freely programmable
Function Blocks / Sequence Programming
N/A N/A - Sequence Programming N/A N/A Yes Yes Yes
PiD loop N/A N/A 2 x Loops with Sleep, 1 x Loop without Sleep
1 x Loops without Sleep, 1 x Loop with Sleep
2 x Loops without Sleep, 1 x Loop with Sleep
2 x Loops without Sleep, 1 x Loop with Sleep
1 x Loop with Sleep 1 x Loop with Sleep 1 x Loop with Sleep
Program interface 8 x DIP Switches 3 x Potentiometers
Basic LCD None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
See the description you currently have in place
See the description you currently have in place
See the description you currently have in place
outputs 1 x N/O Relay Contact (Run or Fault)
1 Form C Relay (NO + NC) 1 x 1 Form C Relay (NO + NC), 1 x Transistor 100mA / 30VDC
(N/O + N/C)3 x Optional Relays 250VAC/30VDC/2A
1 x Form C Relay, 1 x Transistor 100mA / 30VDC (N/O
+ N/C) Optional Relays
3 x Relays with 1 x N/O & 1 x N/C Contact Each2A, 230V Max
3 x Optional Relays with 1 x N/O & 1 x N/C Contacts 2A, 230V Max,
Programmable
3 x Relays with 1 x N/O & 1 x N/C Contact Each2A, 230V Max
3 x Optional Relays with 1 x N/O & 1 x N/C Contacts 2A, 230V Max,
Programmable
3 relay outputs 1 Relay Output & 2 of the inputs can be configured as transistor
outputs
2 Relay Outputs & 2 of the inputs can be configured as
transistor outputs
Special Firmware N/A N/A Pump & Fan Control & Panel Software
Panel Software Panel Software Tailor-made HVAC Software Different Firmware packages available
Standard Induction & permanent magnet motors capability
Tailor-made pump control functions for single and multi-
pump applications
DriveWare DriveConfig Kit FlashDrop DriveWindow Light, FlashDrop DriveWindow Light, FlashDrop DriveWindow Light, FlashDrop DriveWindow Light, FlashDrop Drive Windows Light and Drive Windows
Drive Studio & Drive SPC Drive Studio & Drive SPC
eMC Filter Internal 1st Environment Internal 2nd Environment Internal 2nd Environment Internal 2nd Environment Internal 1st Environment Internal 1st Environment 2nd Environment 2nd Environment 2nd Environment
operation temperature -20 to +40 C˚ -10 to +40 C˚ -10 to +50 C˚ -10 to +40 C˚ -15 to +40 C˚ -15 to +40 C˚ -10 to +40 -10 to +40 -10 to +40
Page reference Page 14-606 Page 14-607 Page 14-608 Page 14-609 Page 14-611 Page 14-613 Page 14-615 Page 14-617 Page 14-614
14-605
14.1. Variable Speed Drives
14
Selection Guide
Hardware Features ACS55 ACS150 ACS310 ACS355 ACS550 ACH550 ACS800 ACS850 ACQ810
Sizes 0.18 to 2.2kW 0.37 to 4kW 0.37 to 22kW 0.37 to 22kW 0.75 to 160kW 0.75 to 355kW 0.55 to 5600 1.1 to 500 0.37 to 400
Accel / Decel times 0.1 to 30sec 0.1 to 1800sec 0.1 to 1800sec 0.1 to 1800sec 0.1 to 1800sec N/A 0.1 to 1800 sec 0.1 to 1800 sec 0.1 to 1800 sec
Supply Voltage ratings 115V, 200/240V 1 Phase 200/240V 1 Phase, 200/240V 3 Phase, 380/480V 3 Phase
200/240V 3 Phase, 380/480V 3 Phase
200/240V 1 Phase, 200/240V 3 Phase, 380/480V 3 Phase
200/240V 3 Phase, 380/480V 3 Phase
200/240V 3 Phase, 380/480V 3 Phase
380 to 690 380 to 500 380 to 480
Motor Control V/Hz only V/Hz only V/Hz only (linear, squared, user defined)
V/Hz, Sensorless Vector & Flux Vector
V/Hz, Sensorless Vector & Flux Vector
V/Hz, Sensorless Vector & Flux Vector
V/Hz & Direct Torque Control (exceeds Flux Vector
Performance)
V/Hz & Direct Torque Control (exceeds Flux Vector
Performance)
V/Hz & Direct Torque Control (exceeds Flux Vector
Performance)
overload torque 150% for 1 min 150% for 1 min 110% for 1 min 150% for 1 min180% for 2 sec
150% for 1 min180% for 2 sec
150% for 1 min180% for 2 sec
150% for 1 min, 200% for 10 sec
150% for 1 min, 200% for 10 sec
110% for 1 min
Dynamic Brake N/A Internal Chopper Standard N/A Internal Chopper Standard Internal Chopper through to 11kWOptional External Brake Chopper
N/A Standard up to 15 kW and then available as an option
Standard N/A
Analog inputs 1 x Configurable 0-10V, 0-20mA or Potentiometer Reference
1 x Configurable 0-10V, 0-20mA or Potentiometer Reference
2 x Non-Isolated Configurable +/- 0-10V, +/-0-20mA or Potentiometer Reference
2 x Configurable 0-10V, 0-20mA or Potentiometer
Reference
2 x Configurable 0-10V, 0-20mA or Potentiometer
Reference
2 x Configurable 0-10V, 0-20mA or Potentiometer
Reference
1 x 0-10V, (2) 0-20mA 2 x configurable as 0-10V or 0-20mA
2 x configurable as 0-10V or 0-20mA
Analog outputs N/A N/A 1 x Non-Isolated 0-20mA 1 x Non-Isolated 0-20mA 2 x Non-Isolated 0-20mA 2 x Non-Isolated 0-20mA 2 x 0-20mA 2 x 0-20mA 2 x 0-20mA
Communications N/A N/A RS232 & RS485 Modbus Standard Modbus, DeviceNet, Profibus, CANopen & Modbus TCP/IP,
Ethernet IP, SREA-01
RS485 Modbus Standard, DeviceNet, Profibus, CANopen & Modbus TCP/IP, Ethernet IP,
ControlNet, SREA-01, EtherCAT
RS485 Modbus, BACnet MS/TP, N2, FLN
Optional BACnet / IP Router, LONworks adapter
DeviceNet, Profibus-DP, Modbus-RTU, Ethernet/
IP, Modbus TCP, Profinet, LonWorks, CANopen, ControlNet SREA-01
DeviceNet, Profibus-DP, Modbus-RTU, Ethernet/
IP, Modbus TCP, CANopen, SREA-01
DeviceNet, Profibus-DP, Modbus-RTU, Ethernet/
IP, Modbus TCP, LonWorks, SREA-01
Digital inputs 3 x 12 to 24VDC Fixed Function – Start/Stop,
Reverse, Jog
5 x 12 to 24VDC All Programmable
Pulse Train (0 to 16kHz)
5 x 12 to 24VDC with internal or external power supply, PNP & NPN,
Pulse Train (0 to 10kHz)
5 x 12 to 24VDC All Programmable
Pulse Train (0 to 10kHz)
6 x 12 to 24VDC StandardAll Programmable
6 x 12 to 24VDCAll Programmable
7, 6 of which are freely programmable
6, freely programmable 6, 5 of which are freely programmable
Function Blocks / Sequence Programming
N/A N/A - Sequence Programming N/A N/A Yes Yes Yes
PiD loop N/A N/A 2 x Loops with Sleep, 1 x Loop without Sleep
1 x Loops without Sleep, 1 x Loop with Sleep
2 x Loops without Sleep, 1 x Loop with Sleep
2 x Loops without Sleep, 1 x Loop with Sleep
1 x Loop with Sleep 1 x Loop with Sleep 1 x Loop with Sleep
Program interface 8 x DIP Switches 3 x Potentiometers
Basic LCD None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
None, Basic LCD or Advanced Interface with Real Time Clock, Full Graphic LCD Screen, Soft Keys &
Parameter Upload/Download
See the description you currently have in place
See the description you currently have in place
See the description you currently have in place
outputs 1 x N/O Relay Contact (Run or Fault)
1 Form C Relay (NO + NC) 1 x 1 Form C Relay (NO + NC), 1 x Transistor 100mA / 30VDC
(N/O + N/C)3 x Optional Relays 250VAC/30VDC/2A
1 x Form C Relay, 1 x Transistor 100mA / 30VDC (N/O
+ N/C) Optional Relays
3 x Relays with 1 x N/O & 1 x N/C Contact Each2A, 230V Max
3 x Optional Relays with 1 x N/O & 1 x N/C Contacts 2A, 230V Max,
Programmable
3 x Relays with 1 x N/O & 1 x N/C Contact Each2A, 230V Max
3 x Optional Relays with 1 x N/O & 1 x N/C Contacts 2A, 230V Max,
Programmable
3 relay outputs 1 Relay Output & 2 of the inputs can be configured as transistor
outputs
2 Relay Outputs & 2 of the inputs can be configured as
transistor outputs
Special Firmware N/A N/A Pump & Fan Control & Panel Software
Panel Software Panel Software Tailor-made HVAC Software Different Firmware packages available
Standard Induction & permanent magnet motors capability
Tailor-made pump control functions for single and multi-
pump applications
DriveWare DriveConfig Kit FlashDrop DriveWindow Light, FlashDrop DriveWindow Light, FlashDrop DriveWindow Light, FlashDrop DriveWindow Light, FlashDrop Drive Windows Light and Drive Windows
Drive Studio & Drive SPC Drive Studio & Drive SPC
eMC Filter Internal 1st Environment Internal 2nd Environment Internal 2nd Environment Internal 2nd Environment Internal 1st Environment Internal 1st Environment 2nd Environment 2nd Environment 2nd Environment
operation temperature -20 to +40 C˚ -10 to +40 C˚ -10 to +50 C˚ -10 to +40 C˚ -15 to +40 C˚ -15 to +40 C˚ -10 to +40 -10 to +40 -10 to +40
Page reference Page 14-606 Page 14-607 Page 14-608 Page 14-609 Page 14-611 Page 14-613 Page 14-615 Page 14-617 Page 14-614
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives Stock Status:
Normally stocked /Not normally stocked
Discount Code C12
14
14.1.1. Micro Drives
ACS55 Series
Micro drives are used in a wide variety of simple machines such as automatic gates, solar trackers, treadmills, whirlpool baths and other applications. They are used in both commercial and domestic environments.
Drive parameters are easily set by configuring the drive’s DIP switches and potentiometers on the front panel. For volume configuration, the optional DriveConfig kit, which includes PC software, can be used. DriveConfig provides advanced drive configuration options with different macros for default I/O connections. DriveConfig can even be used to configure unpowered drives.
Highlights
• Built-in 1st environment EMC filter as standard: suitable for single phase residential and commercial applications• Compact and slim design• Several installation alternatives• Reduced motor noise with high switching frequency• Easy configuration using potentiometers and switches• Fast programming of drives without the need for a power connection
Applications
• Fans and pumps• Exercise equipment• Gate control• Conveyors• Whirlpool baths
order Codes
Accessories
Description Code
Integrated Potentiometer ACS55-Pot
Motor rating (kW)
output Current (A)
Supply Voltage (VAC)
Dimensions (mm) iP rating Code
H W D
0.18 1.4 240 170 45 128 IP20 ACS55-01e-01A4-2
0.37 2.2 ACS55-01e-02A2-2
0.75 4.3 170 67.5 128 ACS55-01e-04A3-2
1.5 7.6 226 70 159 ACS55-01e-07A6-2
2.2 9.8 ACS55-01e-09A8-2
14-607
14.1. Variable Speed Drives Stock Status:Normally stocked /Not normally stocked
Discount Code C12
14
14.1.1. Micro Drives
ACS150 Series
The ACS150 Series drives are designed to be incorporated into a wide variety of machines such as mixers, conveyors, fans or pumps or anywhere where a fixed speed motor needs to run at variable speed.
The ACS150 drives have an integrated user panel and potentiometer, and a variety of features such as macros, which are pre-defined I/O configurations like 3-wire, PID-control and motor potentiometer macro. In addition, the drives offer extensive range of parameters that help obtaining the best performance out of the application.
FlashDrop, an optional drive configuration tool designed for volume configuration, can be used to quickly and easily configure unpowered drives. FlashDrop stores up to 20 different drive parameter sets and can copy parameters from one drive to another, or between a PC and a drive.
Highlights
• User-friendly LCD user panel and integrated potentiometer• Flexible mounting alternatives• PID control• Integrated EMC filter• Built-in brake chopper• FlashDrop tool for fast drive commissioning
Applications
• Conveyors• Mixers• Material handling• Fans and pumps
order Codes
Motor rating (kW)
output Current (A)
Supply Voltage (VAC)
Dimensions (mm) iP rating Code
H W D
0.37 2.4 240 239 70 142 IP20 ACS150-01e-02A4-2
0.75 4.7 ACS150-01e-04A7-2
1.1 6.7 ACS150-01e-06A7-2
1.5 7.5 239 105 142 ACS150-01e-07A5-2
2.2 9.8 ACS150-01e-09A8-2
0.37 1.2 415 239 70 142 IP20 ACS150-03e-01A2-4
0.55 1.9 ACS150-03e-01A9-4
0.75 2.4 ACS150-03e-02A4-4
1.1 3.3 ACS150-03e-03A3-4
1.5 4.1 ACS150-03e-04A1-4
2.2 5.6 ACS150-03e-05A6-4
3 7.3 ACS150-03e-07A3-4
4 8.8 ACS150-03e-08A8-4
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives Stock Status:
Normally stocked /Not normally stocked
Discount Code C12
14
14.1.2. Fan & Pump
ACS310 Series
The ACS310, are dedicated to variable torque applications such as booster pumps and centrifugal fans. The drive design includes a powerful set of features which benefit pump and fan applications including built in PID controllers and PFC (pump and fan control) that varies the drive’s performance in response to changes in pressure, flow or other external data. The drives also have pre-programmed protection functions such as pipe cleaning for preventive maintenance.
The ACS310 drives provide built-in energy efficiency features. Energy savings can be easily monitored using the built-in energy calculators, that display energy savings in kilowatt hours and saved carbon dioxide emissions. The savings can also be displayed in local currencies.
Highlights
• Pump and fan features such as pump and fan control (PFC and SPFC)• Pipe cleaning and fill functions• Energy efficiency calculators• Energy optimizer• Load analyzer for optimized dimensioning of the drive, motor and process• Embedded Modbus EIA-485 fieldbus interface• FlashDrop tool for fast parameter setting• Unified height and depth• Full output current at 50 °C ambient• Short parameter menu view
Applications
• Booster pumps• Irrigation systems• Level control• Centrifugal fans
order Codes
Accessories
Description Code
Basic Control Panel ACS-CP-C
Advanced Control Panel ACS-CP-D
Control Panel 3m Extension Kit ACS/H-CP-eXt
IP66 Control Panel 3m Extension Kit ACS/H-CP-eXt-iP66
Motor rating (kW)
output Current (A)
Supply Voltage (VAC)
Dimensions (mm) iP rating Code
H W D
0.37 1.3 415 239 70 161 IP20 ACS310-03E-01A3-4
0.55 2.1 ACS310-03E-02A1-4
0.75 2.6 ACS310-03e-02A6-4
1.1 3.6 ACS310-03e-03A6-4
1.5 4.5 ACS310-03e-04A5-4
2.2 6.2 ACS310-03e-06A2-4
3 8 ACS310-03e-08A0-4
4 9.7 ACS310-03e-09A7-4
5.5 13.8 236 169 169 ACS310-03e-13A8-4
7.5 17.2 ACS310-03e-17A2-4
11 25.4 ACS310-03e-25A4-4
15 34.1 244 260 169 ACS310-03e-34A1-4
18.5 41.8 ACS310-03e-41A8-4
22 48.4 ACS310-03e-48A4-4
* No control panel with drive, please order separately* Integrated EMC Filter included
14-609
14.1. Variable Speed Drives Stock Status:Normally stocked /Not normally stocked
Discount Code C12
14
14.1.3. Machinery
ACS355 SeriesThe ACS355 Series drives are designed to be fast drives to install, parameter-set and commission. Thus saving hours of engineering work. They are highly compact and cost effective and equipped with cutting edge intelligence and an innovative safety capability. The drives are designed specifically to meet the production and performance needs of system integrators, original equipment manufacturers (OEMs) and panel builders, as well as the requirements of end users in a broad range of applications.
Saving cost with cutting-edge intelligence and flexibility
Up to eight pre-set sequences of operations can be created in minutes with the drive’s PC tool to reduce the need for external PLC components. Versatile fieldbus connectivity to most PLCs on the market is also available. The drive includes Safe torque-off function as standard helping machine builders to fulfil the latest machinery directives.
Additional features include Speed Compensated Stop. This makes the drive ideal for material handling applications that require precision stopping that is independent of variations in process speed. For demanding environments high protection class variants are available in IP66/IP67/UL Type 4X classes that are NSF certified.
Highlights
• Exceptionally compact drives and uniform design• Quick commissioning with application macros and panel assistants• Safe torque-off function (SIL3 ) as standard• Sensorless vector control for induction and permanent magnet motors• Built-in brake chopper• High protection class variants for demanding environments
Applications
• Food & beverage • Material handling • Printing • Rubber & plastics
order Codes
Motor rating (kW)
output Current (A)
Supply Voltage (VAC)
Dimensions (mm) iP rating Code
H W D
0.37 2.4 240 239 70 161 IP20 ACS355-01e-02A4-2
0.75 4.7 ACS355-01e-04A7-2
1.1 6.7 ACS355-01e-06A7-2
1.5 7.5 239 105 165 ACS355-01e-07A5-2
2.2 9.8 ACS355-01E-09A8-2
0.37 1.2 415 239 70 161 IP20 ACS355-03e-01A2-4
0.55 1.9 ACS355-03e-01A9-4
0.75 2.4 ACS355-03e-02A4-4
1.1 3.3 ACS355-03e-03A3-4
1.5 4.1 ACS355-03e-04A1-4
2.2 5.6 ACS355-03e-05A6-4
3 7.3 ACS355-03e-07A3-4
4 8.8 ACS355-03e-08A8-4
5.5 12.5 236 169 169 ACS355-03e-12A5-4
7.5 15.6 ACS355-03e-15A6-4
11 23.1 ACS355-03e-23A1-4
* No control panel included with IP20 versions, please order separately* Integrated EMC Filter
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives Stock Status:
Normally stocked /Not normally stocked
Discount Code C12
14
14.1.3. Machinery
Accessories
Description Code
Basic Control Panel (for IP20 versions) ACS-CP-C
Advanced Control Panel ACS-CP-D
Control Panel 3m Extension Kit (for IP20 versions) ACS/H-CP-eXt
IP66 Control Panel 3m Extension Kit (for IP20 versions) ACS/H-CP-eXt-iP66
DeviceNet Adaptor FDNA-01
Profibus-DP Adaptor FPBA-01
Modbus Adaptor FMBA-01
Ethernet Adaptor (Ethernet IP/Modbus TCP/IP) FENA-01
CANOpen Adaptor FCAN-01
ACS355 Potentiometer MPOT-01
order Codes
Motor rating (kW)
output Current (A)
Supply Voltage (VAC)
Dimensions (mm) iP rating Code
H W D
15 31 415 244 260 169 IP20 ACS355-03E-31A0-4
18.5 38 ACS355-03E-38A0-4
22 44 ACS355-03E-44A0-4
0.37 1.2 415 305 195 281 IP67 ACS355-03E-01A2-4+B063
0.55 1.9 ACS355-03E-01A9-4+B063
0.75 2.4 ACS355-03E-02A4-4+B063
1.1 3.3 ACS355-03E-03A3-4+B063
1.5 4.1 ACS355-03E-04A1-4+B063
2.2 5.6 ACS355-03E-05A6-4+B063
3 7.3 ACS355-03E-07A3-4+B063
4 8.8 ACS355-03E-08A8-4+B063
5.5 12.5 436 246 277 ACS355-03E-12A5-4+B063
7.5 15.6 ACS355-03E-15A6-4+B063
* No control panel included with IP20 versions, please order separately* ACS-CP-D control panel included with IP67 versions* Integrated EMC Filter
ACS355 Series continued
14-611
14.1. Variable Speed Drives Stock Status:Normally stocked /Not normally stocked
Discount Code C12
14
14.1.4. General Purpose
ACS550 Series
The ACS550 Series general purpose drives are simple to buy, install, configure and use, saving considerable time. The drives have common user and process interfaces with fieldbuses, common software tools for sizing, commissioning, maintenance and common spare parts.
Typical applications include pump, fan and constant torque use, such as conveyors. General purpose drives are ideal in those situations where there is a need for simplicity to install, commission and use and where customizing or special product engineering is not required. The drives include several features as standard, such as swinging choke, EMC filter and control panel. All drives are tested with full load at the factory ensuring premium quality.
Energy efficiency achieved with general purpose drives can be easily monitored using the built-in counters, which display energy savings in kilowatt hours, carbon dioxide emissions.
Highlights
• Energy efficiency counters• Intuitive use with assistant control panel• Swinging choke for superior harmonic reduction• Vector control• Coated boards for harsh environments• Built-in category C2 EMC filter (1st environment) as standard• Flexible fieldbus system with builtin Modbus and numerous internally mountable fieldbus adaptors• Brake chopper as standard in the frames R1 and R2• FlashDrop tool for cold configuration
order Codes – iP21, 415VAC
normal Duty Heavy Duty Dimensions (mm) Code
Motor rating (kW)
output Current (A)
Motor rating (kW)
output Current (A)
H W D
1.1 3.3 0.75 2.4 369 125 212 ACS550-01-03A3-4+0J400
1.5 4.1 1.1 3.3 ACS550-01-04A1-4+0J400
2.2 5.4 1.5 4.1 ACS550-01-05A4-4+0J400
3 6.9 2.2 5.4 ACS550-01-06A9-4+0J400
4 8.8 3 6.9 ACS550-01-08A8-4+0J400
5.5 11.9 4 8.8 ACS550-01-012A-4+0J400
7.5 15.4 5.5 11.9 469 125 222 ACS550-01-015A-4+0J400
11 23 7.5 15.4 ACS550-01-023A-4+0J400
15 31 11 23 583 203 231 ACS550-01-031A-4+0J400
18.5 38 15 31 ACS550-01-038A-4+0J400
22 45 18.5 38 ACS550-01-045A-4+0J400
30 59 22 45 689 203 262 ACS550-01-059A-4+0J400
37 72 30 59 ACS550-01-072A-4+0J400
45 87 37 72 ACS550-01-087A-4+0J400
55 125 45 96 736 265 286 ACS550-01-125A-4+0J400
75 157 55 125 888 302 400 ACS550-01-157A-4+0J400
90 180 75 156 ACS550-01-180A-4+0J400
110 205 90 162 ACS550-01-195A-4+0J400
132 246 110 192 979 302 400 ACS550-01-246A-4+0J400
160 290 132 246 ACS550-01-290A-4+0J400
Note: No control panel included, please order separately
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives Stock Status:
Normally stocked /Not normally stocked
Discount Code C12
14
14.1.4. General Purpose
order Codes – iP54, 415VAC
Accessories
Description Code
Basic Control Panel ACS-CP-C
Advanced Control Panel ACS-CP-D
Control Panel 3m Extension Kit ACS/H-CP-eXt
IP66 Control Panel 3m Extension Kit ACS/H-CP-eXt-iP66
DeviceNet Adaptor rDnA-01
Profibus-DP Adaptor rPBA-01
LONWorks Adaptor RLON-01
Control Net Adaptor RCNA-01
CANOpen Adaptor RCAN-01
Ethernet Adaptor (Ethernet IP/Modbus TCP/IP) retA-01
Ethernet Adaptor (Ethernet IP/Modbus TCP/IP, Profinet) RETA-02
normal Duty Heavy Duty Dimensions (mm) Code
Motor rating (kW)
output Current (A)
Motor rating (kW)
output Current (A)
H W D
1.1 3.3 0.75 2.4 461 213 234 ACS550-01-03A3-4+B055+0J400
1.5 4.1 1.1 3.3 ACS550-01-04A1-4+B055+0J400
2.2 5.4 1.5 4.1 ACS550-01-05A4-4+B055+0J400
3 6.9 2.2 5.4 ACS550-01-06A9-4+B055+0J400
4 8.8 3 6.9 ACS550-01-08A8-4+B055+0J400
5.5 11.9 4 8.8 ACS550-01-012A-4+B055+0J400
7.5 15.4 5.5 11.9 561 213 245 ACS550-01-015A-4+B055+0J400
11 23 7.5 15.4 ACS550-01-023A-4+B055+0J400
15 31 11 23 629 256 254 ACS550-01-031A-4+B055+0J400
18.5 38 15 31 ACS550-01-038A-4+B055+0J400
22 45 18.5 38 ACS550-01-045A-4+B055+0J400
30 59 22 45 760 257 284 ACS550-01-059A-4+B055+0J400
37 72 30 59 ACS550-01-072A-4+B055+0J400
45 87 37 72 ACS550-01-087A-4+B055+0J400
55 125 45 96 775 369 309 ACS550-01-125A-4+B055+0J400
75 157 55 125 924 410 423 ACS550-01-157A-4+B055+0J400
90 180 75 156 ACS550-01-180A-4+B055+0J400
110 205 90 162 ACS550-01-195A-4+B055+0J400
132 246 110 192 1119 410 423 ACS550-01-246A-4+B055+0J400
160 290 132 246 ACS550-01-290A-4+B055+0J400
Note: No control panel included, please order separately
14-613
14.1. Variable Speed Drives Stock Status:Normally stocked /Not normally stocked
Discount Code C12
14
14.1.5. HVAC
ACH550 Series
The introduction of a dedicated ABB drive for HVAC marks a significant milestone in the development of AC drives. Macros for the most common applications are built into the drive as standard. The drive is programmed with several HVAC applications, including supply and return fans, cooling tower fans, booster pumps and condensers.
The intelligence within the HVAC control panel means that the user is given direct and understandable instructions in clear text at all times. Harmonics and RFI emissions are major concerns within many HVAC installations. The ABB drive for HVAC fulfils demanding requirements for electromagnetic compatibility. A swinging choke cuts harmonics emissions by up to 25 percent.
Highlights
• EMC filters for building sector, class C2 (1st environment)• Meets mandatory harmonic standard EN 61000-3-12• Built-in Real Time Clock provides true time and date stamps to drive events• Built-in timers allow control of the drive according to the time of day or night• Full motor 9kW output at 50Deg.C• BACNet MS/TP, N2, FLN and Modbus RTU embedded• Taylor made HVAC application macros
order Codes - iP54, 415VAC
Accessories
Description Code
Advanced Control Panel ACS-CP-B
Control Panel 3m Extension Kit ACS/H-CP-eXt
IP66 Control Panel 3m Extension Kit ACS/H-CP-eXt-iP66
DeviceNet Adaptor rDnA-01
Profibus-DP Adaptor rPBA-01
LONWorks Adaptor RLON-01
Control Net Adaptor RCNA-01
CANOpen Adaptor RCAN-01
Ethernet Adaptor (Ethernet IP/Modbus TCP/IP) retA-01
Ethernet Adaptor (Ethernet IP/Modbus TCP/IP, Profinet) RETA-02
BACnet/IP Router Module RBIP-01
normal Duty Dimensions (mm) Code
Motor rating (kW) output Current (A) H W D
0.75 2.4 449 213 234 ACH550-01-02A4-4+B055
1.1 3.3 ACH550-01-03A3-4+B055
1.5 4.1 ACH550-01-04A1-4+B055
2.2 5.4 ACH550-01-05A4-4+B055
3 6.9 ACH550-01-06A9-4+B055
4 8.8 ACH550-01-08A8-4+B055
5.5 11.9 ACH550-01-012A-4+B055
7.5 15.4 549 213 245 ACH550-01-015A-4+B055
11 23 ACH550-01-023A-4+B055
15 31 611 257 254 ACH550-01-031A-4+B055
18.5 38 ACH550-01-038A-4+B055
22 45 ACH550-01-045A-4+B055
30 59 742 257 284 ACH550-01-059A-4+B055
37 72 ACH550-01-072A-4+B055
45 87 ACH550-01-087A-4+B055
55 125 776 369 309 ACH550-01-125A-4+B055
75 157 924 410 423 ACH550-01-157A-4+B055
90 180 ACH550-01-180A-4+B055
110 205 ACH550-01-195A-4+B055
132 246 1119 410 423 ACH550-01-246A-4+B055
160 290 ACH550-01-290A-4+B055
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives
14
14.1.6. Water & Wastewater
ACQ810 Series
The ACQ810 drive for water and wastewater applications features tailor made functions for single and multipump system control. These pump specific functions help reduce total life cycle operating and maintenance costs across the pumping system. The drives achieve this by:
• Reducing startup stress on the pump system• Calculating the required motor speed based current process conditions• Optimizing energy consumption in parallel pumping systems• Sharing operating times across pumps• Monitoring, preventing and scheduling automated pump cleaning runs• Preventing cavitation and pump dry run• Providing redundancy in parallel pump systems• Monitoring energy consumption• Monitoring and protecting the pump’s motor• Displaying energy saving information in kWh, currency or CO2 emissions
Benefits
optimal pump control for various applications
• Raw water pumps, booster pumps, wastewater pumps• Rain water pumps, irrigation pumps, slurry pumps• Submersible pumps, dry-installed pumps
intelligent solution for controlling pump performance
• Tailor-made pump control functions for single and multipump applications• Clear, easy-to-understand documentation and software• Compliance with mandatory EN 61000-3-12 standard on harmonic currents• Advanced energy saving functions
Easy and cost-effective cabinet assembly
• Fast and easy installation• Narrow, compact design• Side-by-side installation saves space• Modular structure provides flexibility in system design and configuration
rapid and simple pumping system startup
• Intelligent startup assistant ensures simple pumping system commissioning• Easy-to-use documentation based on real pumping applications• Preprogrammed and preconfigured macros for typical pump applications
Advanced energy efficiency in pumping systems
• Energy savings up to 50 percent in speed controlled pump applications – save energy and reduce carbon dioxide emissions• Advanced functions such as energy optimizer to improve energy efficiency• Optimized energy consumption in parallel pumping systems• Easy energy efficiency management - built-in calculator monitors used and saved energy and displays them in kWh, currency ($ or €) or volume of CO2 emission
Maximized process uptime
• Maintenance assistant handles preventive maintenance for drive and pump, reminding users about planned maintenance based on running hours• Diagnostic assistant helps to locate problems or reasons for performance changes in pumping system and suggests remedies• Redundancy in parallel pumping systems keeps process running even if one pump fails• Prevention of dry running and cavitation• Coated boards for longer drive lifetime
14-615
14.1. Variable Speed Drives
14
14.1.7. Industrial
ACS800 Series
Single drives are complete AC drives, which can be installed without anyadditional cabinet or enclosure andused in process industries suchas pulp and paper, metals, mining,cement, power, chemical, oil and gas. A single drive configuration contains a rectifier, reactor, DC link and an inverter in one single AC drive unit. Single drives are available as wallmounted, free-standing and cabinetbuiltconstructions. The degree of protection is at least IP21, and higher protection classes are available as an option.
ACS800 Drive Family Descriptions
Common technology for different applicationss
One of the main benefits of the ACS800 series is a wide range of drive products with common technologies. This includes Start-up Assistant, Adaptive Programming and DTC, common user and process interfaces, software tools for sizing, commissioning and maintenance, and common spare parts.
Premium technology Direct torque Control
The heart of the ACS800 is DTC — Direct Torque Control. lt’s a first class motor control system. The consistently excellent performance of the ACS800 guarantees that the drive is not the limiting factor in your process.
DTC technology is well proven in various applications and demanding environments, guaranteeing the high reliability of the drive.
Start-up AssistantABB AC drives have always been top of their class in user-friendliness. This product series brings a whole new meaning to "user-friendliness." Thanks to the Start-up-Assistant, the commissioning and tuning of a high-performance drive could not be easier.
Adaptive Programming
The ACS800 goes one step further (compared to parameter programming) with the addition of Adaptive Programming. It is like having a small PLC inside your drive. Adaptive Programming needs no additional hardware or software but is always there when needed.
integration and Compact Design
Anything that is required from an AC drive, like EMC and harmonic filters, is inside the drive, so no extra space or cabling is needed. Furthermore, there is always space inside the ACS800 for three option modules for I/O extensions, fieldbuses, pulse encoder interface or a PC connection.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives
14
14.1.7. Industrial
FlexibilityThe ACS800 family is a fully configurable product line. It allows the customer to choose what they need and want. The ACS800 is available in a number of packages and configurations:
Direct torque Control technologyDtC technology - key in the ACS800 family
Direct Torque Control is an optimized motor control method for AC drives that allows direct control of all the core motor variables. This opens up AC drive capabilities never before realised and offers benefits for all applications.
What is Direct torque Control?
Direct Torque Control, DTC, is a revolutionary motor control method for AC drives which allows accurate control of both motor speed and torque- without pulse encoder feedback from the motor shaft, down to zero speed!
ln DTC, stator flux and torque ars used as primary control variables. The motor-state calculations are updated by the high speed digital signal processor at 40,000 times a second in the advanced motor software model. Due to the continuous updating of the motor state and the comparison of the actual values to the reference values, every single switching in the drive is determined separately. This faeature will always produce the optimal switching combination and can instantly react to dynamic changes such as load shocks or power interruptions. ln DTC, there is no need for a separate voltage and frequency controlled pulse width modulator.
Unequalled motor speed & torque control
Open—loop dynamic, speed-control accuracy matches that of AC drives using closed loop flux vector control. The ACS800 delivers static speed control accuracy of 0.1 % to 0.5% of nominal speed - more than adequate for most industrial applications. ln applications requiring even more precise speed regulation, an optional pulse encoder can be used. With an open-loop torque step rise time of less than 5 milliseconds - compared to over 100 ms in AC drives using sensorless flux vector control - the ACS800 AC drive is unbeatable.
Standard Module Drives (45 to 560 kW):Designed for efficient installation in user supplied enclosures and offer the most cost-effective solution for performance drives.
Cabinet Drives (45 to 2500 kW):Available in IP21 & IP54 enclosures. Available with hundreds of option combinations, these drives are built to your order and standards.
regenerative AC Drives: Available from 5.5 to 110 kW in IP21 wall mount drive and from 45 to 2800 kW in a IP21 or IP54 cabinet drive.
Standard Wall Mount Drives (75 to 160 kW): Available in IP21 & IP55 enclosures and ready for
installation right on the factory floor.
low Harmonic Drives:Available from 5.5 to 110 kW in IP21 wall mount
drive and from 45 — 2800 KW in IP21 or IP54 cabinet drive. ABB’s LH drives meet AS519—1992
at the drive’s AC input terminals.
14-617
14.1. Variable Speed Drives
14
14.1.7. Industrial
ACS850 Series
The ACS850 Series drives are designed to meet the production and performance needs of machine builders, system integrators, panel builders and end users in a broad range of applications. The compact design of the ACS850 low voltage AC drive makes it ideal for cabinet installation. Direct torque control provides highly accurate motor torque and speed control without any encoder feedback. Depending on the challenges of the application, the drive can be programmed in a variety of ways. The drive´s integrated safety function helps to enhance the safe operation of the application.
Highlights
• Compact size, ideal for cabinets• Easy access to power terminals in cabinet installations• DTC (direct torque control) as standard for highly accurate motor torque and speed control• Wide range of options including fieldbuses and PC tools• Safe torque-off (STO) as standard• Maintenance and diagnostic assistants• Removable memory unit
Diverse options provide flexibility
ACS850 drives feature many options, including various speed feedback devices and different fieldbus adapters. Extensive set of standard inputs and outputs provide easy integration into most applications.
Safety as standard
The drive’s safety functions comply with European Union Machinery Directive 2006/42/EC. Functional safety is provided by integrated safe torque-off (STO), which removes the torque from the motor shaft. Other safety functions such as safe brake control (SBC) and safely limited speed (SLS) are available when combined with external safety components.
Applications
• Cranes• Extruders• Conveyors• Winders• Pumps• Fans• Mixers
The drives provide configuration flexibility from simple parameter linking to creating custom function block programs. A crane control program, developed by ABB is also available.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.1. Variable Speed Drives
14
14.1.8. DC Drives
DCS550 Series
The OEM machine manufacturing market places high demands on modern DC-drives. With its compact dimensions and robust technology, the DCS550 is an ideal drive solution for this market – both in new installations or as a replacement for older analog devices.Integrated “winder”, high-performance field supply and various interfaces provide machine manufacturers with a maximum of flexibility in terms of machine integration. In the DCS550, the extremely user friendly operational concept of the DCS400 has been consistently refined and optimized based on practical experience.
DCS550 – the highlights
• Compact dimensions for installations with limited space• Integrated high performance three phase field exciter up to 35 A• “Winder” with commissioning assistant for easy and fast adaption to applications• Different Fieldbus interfaces (incl. EtherCAT, Profinet…) for easy integration into automation• Additional PID-controller for overriding control functions (e. g. pressure- or level control)• Adaptive programming with Drive AP, ABB’s graphical PC-tool for easy implementation of additional functions• Various start-up assistants and auto-tune functions For fast commissioning• Large control pane for straight forward and self-explanatory operation• Rugged design for rough environments, high reliability
DCS550 – Extensive applications
• Extruders• Sugar centrifuges• Wire drawing machines• Coating lines• Printing machines• Presses• Tools machines main drives• Food processing machines• Woodworking (wooden products and MDF industry)• Retrofit of analog DC-technology
14-619
14.1. Variable Speed Drives
14
14.1.8. DC Drives
DCS800 Series
the latest technology on a proven platform
The DCS800 DC industrial drive is the latest drive from ABB, combining the newest control technology with a thyristor power platform that has been factory-proven all over the world. The DCS800 boasts a wider power range than any other DC drive on the market. The hardware and software are designed with you, the user, in mind. Special features make installation and configuration simple and allow you to customize the application to your needs.
Start-up Assistant
The Start-up assistant is part of the standard DCS800 DC drives software package. It guides you through the commissioning procedure either through the control panel or with your PC using DriveWindow Light. It is multilingual, requests data with clear and plain text messages, and sets the required parameters to your needs.
Adaptive Programming
Adaptive programming gives you the ability to customize the drive to your needs without adding more hardware. Change how a digital output works, modify speed or torque reference, or filter an analog input - all these things are possible. You program the drive with the control panel or you PC using DriveWindow Light. Sixteen function blocks are available. If more are required, Control Builder, which uses compact flash memory, is available with expanded capacity.
Macros
DCS800 drives are equipped with macros to cover the most frequent parameter settings. macros are pre-programmed parameter subsets. The functions of inputs and outputs and elements of the control structure are set up by downloading the macro. Macros will configure for: basic operation, torque control, manual/auto, manual/motor-pot, and motor-pot operation.
Additional Features
• AC and DC contactor control• DC breaker control• Motor brake control• Motor temperature monitoring• Ramp stop, DB stop, and torque limit stop• Field weakening• Field heating (field economy)• Field reversal• Two motor control• Master-Follower operation• 12-pulse operation• Flying start• Drive position display
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtionStock Status:normally stocked /Not normally stocked
14
14.2. Motor Protection Relays
Discount Code A5
Motorvision 2 (MV2) - intelligent Motor Protection & Control relay
Developed from many years experience of intelligent protection and control applications within the high specification offshore / onshore Oil and Gas and Petrochemical sectors. P&B Engineering’s intelligent MV2 has been designed to offer cost effective, versatile, protection and control relaying for low and medium voltage motors forming the integral part of any motor control switchgear.
Highlights
• 4x Output Relays with Changeover Contacts 12x Programmable Digital Inputs• 16K Pixel Graphical LCD• 4x Push Buttons for Menu Driven LCD• 2x Tri Colour LEDs for Indication and Status• 1x Front Mounted RS232 Port• 1x Rear Mounted RS485 Port / Profibus DP 9Way• D Type or Optional RJ45 Ethernet 4x 1A or 5A CT Inputs• 1x VT Inputs• Wide Ranging Auxiliary AC/DC Power Supply Optional Dual channel TCS with 2x C/O Output Relays• Optional 1x RTD/PTC/NTC Input and 4-20mA Output Controller• Optional 3x ph-n VT inputs• Optional 6x or 12x Channel RTD Input
Motorvision [MV2]
Specifically designed to provide complete and comprehensive protection and control for low voltage 3-phase motors which are either circuit breaker or contactor controlled. Multiple starter options provide full control and transfer timing for most DOL, dual wound, reversing, or reduced starting voltage drives. Combined with configurable automatic re-acceleration of the drive on restoration of the auxiliary supply or bus bar voltages. Flexible programming for the digital inputs and relay outputs allow the MV2 to be installed in either the most basic or most complex starter schemes allowing the switchgear designer to easily integrate the MV2 into almost any type of system. Optional Trip Circuit
14.2.1. Motor Temperature Monitoring Relay14.2.2. The Vision Relay Range
order Codes
input output Supply Voltage Code
Thermistors (6max) 1 C/O, 5A / 250VAC 230 VAC Mr-et1P
Mr-et1P
the Vision relay range
• Monitoring of motor temperature• The relay responds to short circuit or wire break• Test function with integrated Test/Reset key• 1 changeover contact: 1 C/O• Ratedload:5A/250VACatcat.AC1
temperature sensor monitoring thermal contact monitoring
note: only one of this circuit versions (either monitoringof the temperature sensor or monitoring of the thermal contact) can be executed.
14-621
14.2. Motor Protection Relays
14
14.2.2. The Vision Relay Range
typical Applications
Supervision and multiple RTD inputs and 3ph VT connections also allow the MV2 to be employed on MV applications, meaning the same MV2 relay can be applied to motors varying from 0.5A, 380V right up to 1.5kA at 22kV. One of the main features of the MV2 is the clear and simple navigation of the graphical display, during starting the graphical display will trend the machine energising current and display this for comparison to a previously recorded starting curve.
Connectivity
As well as comprehensive protection and monitoring the MV2 relay has been designed for integration to control and monitoring systems which allows the protective system to provide remote data telemetry and control. Multiple communication and interface options, including Modbus RTU over RS485, DNP3, Profibus DP, Modbus TCP/IP and IEC61850, allow the MV2 to be connected to virtually any upstream control system.
lCD Display The navigable LCD menu is driven by the four push buttons, this allows access to measured and recorded data as well as providing a programming interface for the relay settings. The large display allows the menu to be structured in an intuitive way to allow easy of use and understanding of the presented information.
Programming
The front RS232 port can be used for local programming or data extraction as well as firmware updates. A Smart Card facility can be included within the relay to further aid programming or be used to collect statistical and recorded data. Settings are stored to a card and those settings can then be downloaded to relays of the same type and function. A credit card sized slot is provided on the rear of the device to allow smart card access whilst the relay remains functional within the panel. Vision Control, P&Bs PC based programming tool can be used to program and configure multiple relays through either communication port. Settings can then be saved, stored & printed.
Disturbance recording
Each relay can be equipped with its own onboard disturbance recording facility. This provides up to 8 seconds of waveform capture and can be multi triggered and weighted pre and post fault. Each phase is individually recorded and can be extracted from the relay using the front RS232 port in a ‘comtrade’ format for analysis by any compatible software. Uniquely, due to the powerful graphical display, waveform traces can also be viewed directly at the relay with zoom and scroll functions without the need for any external equipment.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.2. Motor Protection Relays
14
14.2.3. Retrofit/Replacement
MPr3e5
Vision3000
PBSJ Retrofit
The new MPR3E5 relay, for motor overload and earth fault protection of LV and MV motors, uses the same pin out as the original relay providing a direct and immediate replacement. The fixed case provides self shorting CT contacts when the relay body is withdrawn. As the pin out is uniform across the 100 series case format, we can provide other protective functions within this same relay size. Refer to 100 series relays within the Vision range for further information.
replacement Protection relay
A replacement relay body which is directly compatible with the existing terminals of the older MPR3E5.100x150mm Drawout Case.2 line, 16 Char LCD with 2x Tri-Colour LEDs, 2x DIs, 4x DOs, 4x CTs, (or 4x VTs : function dependent)
Designed as a Replacement for the original MPC2000 relay available in either a vertical or horizontal mounting. This relay is mounted within a 192x96mm case and comes complete with an adaptor plate to mount neatly within the original relay cut-out. The new terminals replicate that of the existing relay, although by the very nature that the terminals were a mix of both screw and plug in type, there are some reconnections to be made to the new relay.
intelligent Protection & Control
A replacement relay for the original and very successful MPC2000 either vertically or horizontally mounted.192x96mm DIN Case mounted within a dished adaptor plate to the original cutout size.50x50mm Graphical LCD with 9x Status LEDs, 19x DIs, 4x DOs, 4x CTs, 3x VTs, 5x RTDs
The PBSJ retrofit uses a vertical Motorvision (MV2) or Feeder Protection Control (FPC) relay mounted within a pre-wired chassis which provides the same terminations in the same position as the existing relay. The replacement is therefore extremely quick, involving the removal of the older relay and the installation of the new relay without panel aperture adjustment or any wiring changes.
replacement Protection relay
A direct replacement for the PBSJ range of relays and the ABB SPAM and SPAJ range of relays, suitable for motor overload or overcurrent and earth fault protection applications using a vertically mounted vision relay.144x96mm DIN Case mounted within a prewired chassis of the same aperture size of the original PBSJ relay. 50x50mm Graphical LCD, 2x Tri-Colour LEDs, 12x DIs, 4x DOs, 4x CTs, 1x VT
14-623
14.2. Motor Protection Relays
14
14.2.3. Retrofit/Replacement
Golds Retrofit
MPr/MPC3000
The P&B Golds was regarded by many as the finest motor protection relay ever made, this direct replacement provides motor overload or overcurrent and earth fault protection using a vertically mounted vision relay. The flag reset plunger now makes contact with a convenient reset switch. The existing relay chassis is removed of its electromechanical contents and the vertical vision relay is mounted to newly fitted stirrups, the terminals are then wired directly to the existing contacts of the Golds chassis. The whole process is fast and could easily be carried out as a site work-scope.
replacement Protection relay
Direct replacement providing motor overload or overcurrent and earth fault protection using a vertically mounted vision relay housed within the Gold relay's withdrawable chassis.l44x96mm DIN Case mounted within a prewired withdrawable chassis50x50mm Graphical LCD, 2x Tri-Colour LEDs, 12x Dls, 4x DOs, 4x CTs, 1 x VT
The MPR2000 or MPC2000D has been used extensively for protection of large motors in many industries.
The 3000 is a replacement module, meaning the wired 2000 blue casing remains in place within the switchgear panel and the new relay module fits directly without the need for any wiring alterations. Those familiar with the 2000 will recognise the LED status bank and the intuitive graphical display adds a further dimension of relay operability. The bezel mounted push button will even align with the fault reset/display scroll prompt key of the new relay. The 3000 can be provided with its casing for use in new projects or extensions.
intelligent Protection & Control
Replacement module using the Vision relay hardware which is directly compatible with the withdrawable MPR2000, MPC2000D.200x150mm Drawout Case50x50mm Graphical LCD with 9x Status LEDs, 5x DIs (19x DIs MPC), 4x DOs, 4x CTs, 3x VTs, 5x RTDs
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion
14
14.3. Soft Starters14.3.1. Overview
PSr PSe PSt (B) • Standard о Optional - Not available
• • • 1) Built-in bypass 1) on PSTB
- - • Inside delta connection
- • о Coated PCBs
- • • Display and keypad
- • • Torque control
- • • Settable current limit function
- • • Electronic motor overload protection
- - • PTC input for motor protection
- - • Phase imbalance protection
- - • Phase reversal protection
- • • Locked rotor protection
- • • Thyristor overtemperature protectio
- • • Underload protection
- - • Programmable warning functions
- • • Analogue output
о о • FieldBus communication
- о • Event log
- о о External keypad
ABB Softstarters
The Softstarter is the solution to both mechanical and electrical problems.
Fewer electrical problemsThe starting current will be significantly lower than with direct on line (DOL) starting and compared with Y/D starters the switching transients will be eliminated.
Fewer mechanical problemsSlipping drive belts and gearbox wear caused by heavy torque peaks are familiar problems that require lots of maintenance. Softstarters reduce the torque peaks as they apply the torque smoothly.
Fewer operational problemsPressure surges in pipelines are often called water hammer. It is a common but undesirable effect when stopping almost all pumps. Softstarters allow smooth stops and reduce the problems associated with water hammer. The torque control algorithm in the PST (B) softstarter guarantees the elimination of water hammer in pumping applications.
typical Applications:• Pumps• Fans• Compressors• Conveyors
ABB Softstarters - Advanced, Flexible and Compact Range
ABB offers three different ranges of softstarter to cover every customer need for solutions for small to medium sized motor applications.
PSr - Compact range up to 105 Amp covers motor currents from up to 105A. Simple to use with inbuilt bypass contacts, the PSR can be connected to MS motor circuit breakers to offer the perfect solution for simple motor starting applications.
PSE - Efficient range from 18 to 370 Amp offers torque control and advanced functionality for most applications with built-in HMI and bypass contactor.
PSt (B) - Advanced range from 9 to 1050 Amp provides advanced functionality, including integrated protections, programmable signal relays, a flexible communication system, plain text LCD display and torque control.
• Crushers• Mixers• Lifting equipment• Escalators
14-625
14.3. Soft Starters
14
14.3.1. Overview
the Complete range
PSr - the compact range, 3 to 105A
The PSR softstarter is the most compact of all the softstarter ranges, thereby making it possible to design compact starting equipments. The system concept with Manual Motor Starters and the PSR provides a far more compact starting solution than for instance a star-delta starter.
Built-in by-pass reduces the energy loss and makes the connection easier and with only three potentiometers the set-up couldn’t be any easier. Still, the optimized ramping characteristics will ensure a very smooth start and stop for all applications.
PSE – The efficient range, 18 to 370A
The PSE softstarter is the world’s first compact softstarter with both built-in electronic overload for motor protection and torque control for an excellent control of pumps. The compact design with the most important functionality integrated provides a very efficient starting solution.
The illuminated language neutral display and the four button keypad make it easy to take advantage of all the advanced functionality in the softstarter. The display will also provide all the necessary information both during ramping and continuous operation.
PSt(B) – the advanced range, 9 to 1050A
The PST(B) softstarter is the most advanced softstarter in the range with almost all imaginable functionality included. All the advanced protections for the motor, the softstarter and the load ensure a trouble free operation. Pre-warnings even allow problems to be detected before the motor needs to be stopped and thereby avoiding unnecessary downtime.
The torque control function has been developed and tested together with well known pump manufacturers to ensure the absolutely best possible stop of pumps without water hammering and pressure surges.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.3. Soft Starters Stock Status:
Normally stocked /Not normally stocked
14
Discount Code C11
14.3.2. Compact Range up to 105A
PSr Series
The PSR softstarter is the most compact of all the softstarter ranges, thereby making it possible to design compact starting equipments. The system concept with Manual Motor Starters and the PSR provides a far more compact starting solution than for instance a star -delta starter.
Built-in by-pass reduces the energy loss and makes the connection easier and with only three potentiometers, the set-up couldn’t be any easier. Still, the optimized ramping characteristics will ensure a very smooth start and stop for all applications.
order Codes
Accessories
Description Code
Connection kit PSR3-16 and MS116 or MS132 PSR16 MS116
Connection kit PSR25-30 and MS132-12 or MS132-32 PSR16 MS132
Connection kit PSR37-45 and MS450 PSR16 MS450
Connection kit PSR60-105 and MS495 PSR16 MS495
Fan PSR3-45 PSR FAN
Fan PSR60-105 PSR FAN 60
Motor rating (kW) @ 415V output Current (A) Code
1.5 3.9 PSR3-600
3 6.8 PSR6-600
4 9 PSr9-600
5.5 12 PSr12-600
7.5 16 PSr16-600
11 25 PSr25-600
15 30 PSr30-600
18.5 37 PSr37-600
22 45 PSr45-600
30 60 PSR60-600
37 72 PSr72-600
45 85 PSR85-600
55 105 PSr105-600
14-627
14.3. Soft Starters Stock Status:Normally stocked /Not normally stocked
14
Discount Code C11
14.3.3. Efficient Range up to 370A
The PSE softstarter is the world’s first compact softstarter with both built-in electronic overload for motor protection and torque control for an excellent control of pumps. The compact design with the most important functionality integrated provides a very efficient starting solution.
The illuminated language neutral display and the four button keypad make it easy to take advantage of all the advanced functionality in the softstarter. The display will also provide all the necessary information both during ramping and continuous operation.
PSe Series
order Codes
Accessoriesterminal enlargements
terminal nut Washer
terminal nut Washer
terminal Shrouds
Motor rating (kW) @ 415V output Current (A) Code
7.5 18 PSE18-600-70
11 25 PSE25-600-70
15 30 PSE30-600-70
18.5 37 PSE37-600-70
22 45 PSE45-600-70
30 60 PSE60-600-70
37 72 PSE72-600-70
45 85 PSE85-600-70
55 106 PSE105-600-70
75 143 PSE142-600-70
90 171 PSE170-600-70
110 210 PSE210-600-70
132 250 PSE250-600-70
160 300 PSE300-600-70
200 370 PSE370-600-70
For Softstarter type Dimensions Hole Dia. (mm2) Bar (mm) Code
PSE18…105 10.5 17.5 x 5 LW110
PSE142…170 10.5 20 x 5 LW185
PSE210…370 13 40 x 6 LW300
For Softstarter type Suitable for req. Qty Code
PSE142…170 Cable Connectors 2 LT185-AC
PSE142…170 Compression Lugs 2 LT185-AL
PSE210…370 Cable Connectors 2 LT300-AC
PSE210…370 Compression Lugs 2 LT300-AL
For Softstarter type req. Qty Code
PSE142…170 2 LE185
PSE210…370 2 LE300
For Softstarter type Code
PSE18…370 PSEEK
lt ... –Al
lW...
le185
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.3. Soft Starters Stock Status:
Normally stocked /Not normally stocked
14
Discount Code C11
14.3.4. Advanced range up to 1050A
PSt & PStB Series – 9 to 1050A, 415V in-line 3-Wire Connection
PSt & PStB Series – 9 to 1050A, 415V inside Delta 6-Wire Connection
order Codes
order Codes
Motor rating (kW) @ 415V output Current (A) Current Setting range (A) Code
15 30 9.0 – 30 PST30-600
18.5 37 11.1 – 37 PST37-600
22 44 13.2 – 44 PST44-600
25 50 15.0 – 50 PST50-600
30 60 18.0 – 60 PST60-600
37 72 21.6 – 72 PST72-600
45 85 25.5 – 85 PST85-600
55 105 31.5 – 105 PST105-600
75 142 42.6 -142 PST142-600
90 175 52.5 – 175 PST175-600
110 210 63.0 – 210 PST210-600
132 250 75.0 – 250 PST250-600
160 300 90.0 – 300 PST300-600
200 370 111 – 370 PSTB370-600
250 470 141 – 470 PSTB470-600
315 570 171 – 570 PSTB570-600
400 720 216 – 720 PSTB720-600
450 840 280 – 840 PSTB840-600
560 1050 315 – 1050 PSTB1050-600
Motor rating (kW) @ 415V output Current (A) Current Setting range (A) Code
25 52 9.0 – 30 PST30-600
30 64 11.1 – 37 PST37-600
37 76 13.2 – 44 PST44-600
45 85 15.0 – 50 PST50-600
55 105 18.0 – 60 PST60-600
59 124 21.6 – 72 PST72-600
75 147 25.5 – 85 PST85-600
90 181 31.5 – 105 PST105-600
132 245 42.6 -142 PST142-600
160 300 52.5 – 175 PST175-600
184 360 63.0 – 210 PST210-600
220 430 75.0 – 250 PST250-600
257 515 90.0 – 300 PST300-600
355 640 111 – 370 PSTB370-600
450 814 141 – 470 PSTB470-600
560 987 171 – 570 PSTB570-600
710 1247 216 – 720 PSTB720-600
800 1455 280 – 840 PSTB840-600
1000 1810 315 – 1050 PSTB1050-600
The PST(B) softstarter is the most advanced softstarter in the range with almost all imaginable functionality included. All the advanced protections for the motor, the softstarter and the load ensure a trouble free operation. Pre-warnings even allow problems to be detected before the motor needs to be stopped and thereby avoiding unnecessary downtime.
The torque control function has been developed and tested together with well known pump manufacturers to ensure the absolutely best possible stop of pumps without water hammering and pressure surges. With the full text LCD display in your own language, pre-programmed application settings and event logging, it couldn’t be easier to set-up and operate.
By using the ABB FieldBusPlug, you can decide at any time which bus protocol to use. The fieldbus system will allow you to set-up, control and monitor the softstarter.
14-629
14.3. Soft Starters Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
14.3.4. Advanced range up to 1050A
Accessories PSt & PStB
terminal enlargements
Terminal Extensions
Connection Kit
External Keypad incl. 3m Cable
terminal Shrouds
For Softstarter type Dimensions Hole Dia. (mm2) Bar (mm) Code
PST30…72 6.5 15 x 3 LW110
PST85…142 10.5 17.5 x 5 LW185
PST175…300 10.5 20 x 5 LW300
PSTB370…470 10.5 25 x 5 LW460
PSTB570…1050 13 40 x 6 LW750
For Softstarter type Dimensions Hole Dia. (mm2) Bar (mm) Code
PST85…142 8.5 17.5 x 5 LX185
PST175…300 10.5 20 x 5 LX300
PSTB370…470 10.5 25 x 5 LX460
PSTB570…1050 13 40 x 6 LX750
For Softstarter type Suitable for req. Qty Code
PST85…142 Cable Connectors 1 LT185AC
1 LT460AC
PST85…142 Compression Lugs 1 LT185AL
1 LT460AL
PST175…300 Cable Connectors 3 LT300AC*
Compression Lugs 3 LT300AL*
PSTB370…470 Cable Connectors 2 LT460AC
Compression Lugs 2 LT460AL
PSTB570…1050 Cable Connectors 2 LT750AC
Compression Lugs 2 LT750AL
For Softstarter type Code
PST85…142 LE185*
PST175…300 LE300**
PSTB370…470 LE460
PSTB570…1050 LE750
For Softstarter type Code
PST30…300, PSTB370…1050 PSTEK
lt ... –Al
PSteK
lW...
lX...
le185
* Only fits on the motor side** Use 2 sets of the accessories on the line side and 1 set on the motor side
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtionStock Status:normally stocked /Not normally stocked
14
Discount Code C10
14.4. Contactors14.4.1. 3-Pole AC Operated14.4.2. 3-Pole DC Operated
Ae 95-30-00
Ae 50-30-00
Al 40-30-10
A 50-30
A 95-30
A 300-30
3-Pole Contactors AC operated - A40...A300 Series
3-Pole Contactors DC operated - Al40...Ae110 Series
order Codes
order Codes
Coil Voltages and Codes
Coil Voltages and Codes
415V 415V 690V 690V 1000V Aux. Contacts Code
AC-3 (kW) AC-3 (A) AC-3 (A) AC-1 (A) AC-3 (A) no nC
18.5 37 25 60 1 - A 40-30-10**
- 1 A 40-30-01**
25 50 35 100 23 1 1 A 50-30-11**
37 65 43 115 25 1 1 A 63-30-11**
40 75 46 125 28 1 1 A 75-30-11**
55 96 65 145 30 1 1 A 95-30-11**
59 110 82 160 30 1 1 A 110-30-11**
75 145 120 250 80 1 1 A 145-30-11**
90 185 170 275 95 1 1 A 185-30-11**
110 210 210 350 1 1 A 210-30-11**
140 260 220 400 1 1 A 260-30-11**
160 300 280 500 1 1 A300-30-10**
** Complete code with coil voltage. Eg: A 50-30-11 81 for 24VAC (see table below)Note: For current ratings up to 40A select from the AF Series on the next page.
415V 415V 690V 690V Aux. Contacts Code
AC-3 (kW) AC-3 (A) AC-3 (A) AC-1 (A) no nC
18.5 37 25 60 1 - AL40-30-10**
- 1 AL40-30-01**
25 50 35 100 1 1 AE50-30-11**
37 65 43 115 1 1 AE63-30-11**
40 75 46 125 1 1 AE75-30-11**
55 96 65 145 1 1 AE95-30-11**
59 110 82 160 1 1 AE110-30-11**
** Complete code with coil voltage. Eg: A L40-30-10 81 for 24VDC (see table below)Note: For current ratings up to 30A select from the AF Series on the next page.
Voltage (AC) @ 50Hz ** = Code
24 81
48 83
110 84
220…230 80
230…240 88
400…415 86
Voltage @ 50Hz ** = Code
12 80
24 81
48 83
110 86
125 87
220 88
240 89
250 38
14-631
14.4. Contactors Stock Status:Normally stocked /Not normally stocked
14
Discount Code C10
14.4.3. 3-Pole AC/DC Operated
3-Pole Contactors AC/DC operated - AF09Z...AF38Z Series
order Codes
Coil Voltages and Codes
415V 415V 690V 690V Aux. Contacts Code
AC-3 (kW) AC-3 (A) AC-3 (A) AC-1 (A) no nC
4 9 7 25 - 1 AF09Z-30-01**
4 9 7 25 1 - AF09Z-30-10**
5.5 12 9 28 - 1 AF12Z-30-01**
5.5 12 9 28 1 - AF12Z-30-10**
9 18 10.5 30 - 1 AF16Z-30-01**
9 18 10.5 30 1 - AF16Z-30-10**
11 26 17 45 - - AF26Z-30-00**
11 26 17 45 1 1 AF26Z-30-11**
15 32 21 50 - - AF30Z-30-00**
15 32 21 50 1 1 AF30Z-30-11**
18.5 38 24 50 - - AF38Z-30-00**
18.5 38 24 50 1 1 AF38Z-30-11**
** Complete code with coil voltage. Eg: A L40-30-10 81 for 24VDC (see table below)
Voltage (AC) @ 50Hz Voltage (DC) ** = Code
12…20 20
24…60 20…60 21
48…130 48…130 22
100…250 100…250 23
AF09Z-30
AF16Z-30
Low coil consumption for direct PLC control
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.4. Contactors Stock Status:
Normally stocked /Not normally stocked
14
Discount Code C10
14.4.3. 3-Pole AC/DC Operated
3-Pole Contactors AC/DC operated - AF09...AF2050 Series
order Codes
415V 415V 690V 690V 1000V 1000V 1000V Aux. Contacts Code
AC-3 (kW) AC-3 (A) AC-3 (A) AC-1 (A) AC-3 (kW) AC-3 (A) AC-1 (A) no nC
4 9 7 25 - 1 AF09-30-01**
4 9 7 25 1 - AF09-30-10**
5.5 12 9 28 - 1 AF12-30-01**
5.5 12 9 28 1 - AF12-30-10**
9 18 10.5 30 - 1 AF16-30-01**
9 18 10.5 30 1 - AF16-30-10**
11 26 17 45 - - AF26-30-00**
11 26 17 45 1 1 AF26-30-11**
15 32 21 50 - - AF30-30-00**
15 32 21 50 1 1 AF30-30-11**
18.5 38 24 50 - - AF38-30-00**
18.5 38 24 50 1 1 AF38-30-11**
25 50 35 100 1 1 AF50-30-11**
37 65 43 115 1 1 AF63-30-11**
40 75 46 125 1 1 AF75-30-11**
55 96 65 145 40 30 1 1 AF95-30-00**
59 110 82 160 40 30 1 1 AF110-30-11**
75 145 120 250 110 80 180 1 1 AF145-30-11**
90 185 170 275 132 95 200 1 1 AF185-30-11**
110 210 210 350 1 1 AF210-30-11**
140 260 220 400 1 1 AF260-30-11**
160 300 280 500 1 1 AF300-30-11**
220 400 350 600 220 155 600 1 1 AF400-30-11**
250 460 400 700 280 200 700 1 1 AF460-30-11**
355 580 500 800 355 250 800 1 1 AF580-30-11**
425 750 650 1050 400 300 1000 1 1 AF750-30-11**
500 860 800 1350 1350 1 1 AF1350-30-11**
600 1050 950 1650 1650 1 1 AF1650-30-11**
2050 2050 1 1 AF2050-30-11**
** Complete code with coil voltage. Eg: AF50-30-11 72 for 24VDC (see tables below)
AF 460–30
AF 750–30
AF 1650-30
AF 300–30
Coil Voltages and Codes: AF09…AF38 Coil Voltages and Codes: AF50…AF300
Coil Voltages and Codes: AF400…AF1250 Coil Voltages and Codes: AF1350…AF2050
Voltage (AC) @ 50Hz
Voltage (DC) ** = Code
24…60 20…60 11
48…130 48…130 12
100…250 100…250 13
250…500 250…500 14
Voltage (AC) @ 50Hz
Voltage (DC) ** = Code
- 20…60 72
48…130 48…130 69
100…250 100…250 70
Voltage (AC) @ 50Hz
Voltage (DC) ** = Code
20…60 68
48…130 48…130 69
100…250 100…250 70
250…500 250…500 71
Voltage (AC) @ 50Hz
Voltage (DC) ** = Code
100…250 100…250 70
14-633
14.4. Contactors Stock Status:Normally stocked /Not normally stocked
14
Discount Code C10
14.4.4. 4-Pole AC/DC Operated
Coil Voltages and Codes: AF09…AF38
Coil Voltages and Codes: AF45…AF75
order Codes
Voltage (AC) @ 50Hz Voltage (DC) ** = Code
24…60 20…60 11
48…130 48…130 12
100…250 100…250 13
250…500 250…500 14
Voltage (AC) @ 50Hz Voltage (DC) ** = Code
- 20…60 72
48…130 48…130 69
100…250 100…250 70
4-Pole Contactors AC/DC operated - AF09...AF75 Series
AF09–40
AF45–40
690V Aux. Contacts Code
AC-1 (A) no nC
4 no main poles AC/DC coil
25 - - AF09-40-00**
30 - - AF16-40-00**
45 - - AF26-40-00**
55 - - AF38-40-00**
70 - - AF45-40-00**
100 - - AF50-40-00**
125 - - AF75-40-00**
2 no + 2 nC main poles AC/DC coil
20 - - AF09-22-00**
30 - - AF16-22-00**
45 - - AF26-22-00**
55 - - AF38-22-00**
70 - - AF45-22-00**
125 - - AF75-22-00**
** Complete code with coil voltage. Eg: AF16-40-00 11 for 24VDC (see tables below)
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.4. Contactors Stock Status:
Normally stocked /Not normally stocked
14
Discount Code C10
14.4.4. 4-Pole AC/DC Operated
Coil Voltages and Codes: AF09Z…AF38Z
Coil Voltages and Codes: AF45…Ae75 DC Coil Voltages and Codes
order Codes
order Codes
Voltage (AC) @ 50Hz Voltage (DC) ** = Code
- 12…20 20
24…60 20…60 21
48…130 48…130 22
100…250 100..250 23
4-Pole AC/DC operated - AF09Z...AF38Z Series
4-Pole AC/DC operated - A45...Ae75 Series
690V Aux. Contacts Code
AC-1 (A) no nC
4 no main poles AC/DC coil
25 - - AF09Z-40-00**
30 - - AF16Z-40-00**
45 - - AF26Z-40-00**
55 - - AF38Z-40-00**
2 no + 2 nC main poles AC/DC coil
20 - - AF09Z-22-00**
30 - - AF16Z-22-00**
45 - - AF26Z-22-00**
55 - - AF38Z-22-00**
** Complete code with coil voltage. Eg: AF09Z-40-00 21 for 24VDC (see tables below)
690V Aux. Contacts Code
AC-1 (A) no nC
4 no main poles AC coil
70 - - A 45-40-00**
100 - - A 50-40-00**
125 - - A 75-40-00**
4 nC main poles AC coil
30 - - A 16-04-00**
2 no + 2nC main poles AC coil
70 - - A 45-22-00**
125 - - A 75-22-00**
4 no main poles DC coil
70 - - AE 45-40-00**
125 - - AE 75-40-00**
2 no + 2 nC main poles DC coil
70 - - AE 45-22-00**
125 - - AE 75-22-00**
** Complete code with coil voltage. Eg: AE 45-40-00 88 for 240VAC (see tables below)
Voltage (AC) @ 50Hz ** = Code
24 81
48 83
110 84
230 80
230…240 88
400…415 86
Voltage (DC) ** = Code
24 81
48 83
110 86
125 87
220 88
240 89
250 38
Low coil consumption for direct PLC control
AF09–40
AF45–40
14-635
14.4. Contactors Stock Status:Normally stocked /Not normally stocked
14
Discount Code C10
14.4.5. A & AF Series Accessories
order Codes
order Codes
Auxiliary Contact Blocks
Pneumatic timers
Positioning Mounting on Contacts Code
no nC
Front A 9…A 110, AL…AE, AF 50…AF 110 1 - CA 510
- 1 CA 501
A9…A 40-30-01, AL…AE 3 1 CA 531 M
2 2 CA 522 M
A 9…A 40-30-01, AL…AE 4 - CA 540 U
2 2 CA 531 U
A 50…A 110, AE/AF 50…AF 110, A 9…A 26 4 pole
4 - CA 540 E
3 1 CA 531 E
2 2 CA 522 E
AF 45 – AF 110 2 2 CA 522 E
3 1 CA 531 E
4 - CA 540 E
- 4 CA 504 E
Side A 9 – A 300, AF 45 – AF 750 1 1 CAL 511
A/AF 145 – A/AF 750 1 1 CAL 511B
A/AF 95 – A/AF 2050 1 1 CAL 1811
A/AF 145 – A/AF 2050 1 1 CAL 1811 B
Mounting on timing range Contacts Code
no nC
A 9…A 75AF 50 – AF 75
Delay On 0.1…40s 1 1 TP 40 DA
Delay On 10…180s 1 1 TP 180 DA
Delay Off 0.1…40s 1 1 tP 40 iA
Delay Off 10…180s 1 1 TP 180 IA
CAl 511
CA 510
tP 40 DA
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.4. Contactors Stock Status:
Normally stocked /Not normally stocked
14
Discount Code l10
14.4.5. A & AF Series Accessories
Coil Voltages and Codes: A9…Ae75
order Codes
order Codes
order Codes
Mechanical latch
interlocks
Surge Suppressors
to suit contactors Code
A 9…A 75, AF 50…AF 75, AL 9…AL 40, AL 9Z…AL 16Z, AE 45…AE 75 WB 75A**
Feature Mounting on Contacts Code
no nC
Mech/Elect A 9…A 40 - 2 Ve 51
A 50…A 110 - 2 VE 52
AF 09…AF 38 - 2 VEM4
Mech A 9…A 40 - 2 VM 51
Note : Use type VE 52 for mechanical & electrical interlocking between contactors A40 & A50
Feature Mounting on Contacts Code
Varistor A 9…A 110 24…50V AC/DC RV 5/50
50…133V AC/DC RV 5/133
110…250V AC/DC RV 5/250
250…440V AC/DC RV 5/440
RC A 9…A 40 24…50V AC RC 51/50
50…133V AC RC 51/133
110…250V AC RC 51/250
250…440V AC RC 51/440
A 50…A 110A 145…A 300
24…50V AC RC 52/50
50…133V AC RC 52/133
110…250V AC RC 52/250
250…440V AC RC 52/440
Voltage (AC) @ 50Hz ** = Code
24 01
48 03
110 04
230…240 05
380…440 07
440…480 08
WB 75
Ve 51
rV 5/50
rC 51/50
14-637
14.4. Contactors Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
14.4.5. A & AF Series Accessories
order Codes
order Codes
Mechanical interlocking of two Horizontally Mounted Contactors
Mechanical interlocking of two Vertically Mounted Contactors
left Contactor right Contactor Code
A/AF 95…A/AF 300 A 145…A 300 VM 300H
A/AF 210…A/AF 300 A 400…A 460 VM 300/460H
AF 400…AF 750 AF 400…AF 750 VM 750H
AF 1350…AF 2050 AF 1350…AF 2050 VM1650H
left Contactor right Contactor Code
AF 95…AF 300 AF 145…AF 300 VM 300V
AF 210…AF 300 AF 400…AF 460 VM 300/460V
AF 400…AF 750 AF 400…AF 750 VM 750V
VM 300H
order Codes
3-Pole Connections for Phase to Phase
Application: Connections between the main poles of two 3-pole contactors horizontal mounted
Mounting on 3-pole contactors Code
AF 50…AF 75 BEM75-30
AF 95, AF 110 BEM110-30
AF 125, AF 185 BEM185-30
AF 210…AF 300 BEM300-30
AF 400, AF 460 BEM460-30
AF 580, AF 750 BEM750-30
Mounting on 3-pole contactors Code
AF 50…AF 75 BES75-30
AF 95, AF 110 BES110-30
AF 125, AF 185 BES185-30
AF 210…AF 300 BES300-30
AF 400, AF 460 BES460-30
AF 580, AF 750 BES750-30
order Codes
Connection Sets for reversing Contactors
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.4. Contactors Stock Status:
Normally stocked /Not normally stocked
14
Discount Code l10
14.4.6. AF 09…AF 38 Accessories
order Codes
order Codes
order Codes
Side Mounted Instantaneous Auxiliary Contact Blocks
Front Mounted Instantaneous Auxiliary Contact & A1/A2 Coil Terminal Blocks
Additional Coil terminal Block
For Contactors Aux. Contacts Aux. Contacts Contacts Code
no nC no lead nC lag
AF 09…AF30 AF 09…AF 38-40-00
1 1 - - CAL4-11
For Contactors Aux. Contacts Aux. Contacts Contacts Code
no nC no lead nC lag
AF 09…AF 16..-30-10 1 1 - - CAT4-11M
AF 26…AF 30..-30-00AF 09…AF 38-40-00 AF 09…AF38-22-00
1 1 - - CAT4-11E
AF 09…AF 16..-30-01 1 1 - - CAT4-11U
For Contactors Code
AF 09…AF 30 LDC4
lDC4
CAl4-11
CAt4-11M
order Codes
order Codes
Front Mounted Auxiliary Contact Blocks with NO Leading & Lagging Contacts
Front Mounted Instantaneous Auxiliary Contact Blocks
For Contactors Aux. Contacts Contacts Code
no nC no lead nC lag
AF 09…AF30 AF 09…AF 38-40-00 AF 09…AF38-22-00
1 0 - - CA4-10
0 1 - - CA4-01
AF 09…AF16..-30-10 2 2 - - CA4-22M
3 1 - - CA4-31M
1 3 - - CA4-13M
0 4 - - CA4-04M
AF 26…AF 30..-30-00 AF 09…AF 38-40-00 AF 09… AF 38-22-00
2 2 - - CA4-22E
3 1 - - CA4-31E
4 0 - - CA4-40E
0 4 - - CA4-04E
AF 09…AF 16..-30-01 2 2 - - CA4-22U
3 1 - - CA4-31U
4 0 - - CA4-40U
For Contactors Aux. Contacts Contacts Code
no nC no lead nC lag
AF 09…AF30AF 09…AF 38-40-00 AF 09…AF38-22-00
- - 1 0 CC4-10
- - 0 1 CC4-01
CA4-10
CA4-22
14-639
14.4. Contactors Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
14.4.6. AF 09…AF 38 Accessories
order Codes
order Codes
order Codes
order Codes
Mechanical interlock Unit
Connecting links with Manual Motor Starters
Mechanical and electrical interlock Set
Protective Covers Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
For Contactors Code
AF 09…AF 38 VM4
For Contactors Code
AF 09…AF 16 with MS116 and MS132 BEA16-4
AF 26…AF 38 with MS132-12…MS132-32 BEA38-4
Description Code
All 1-stack contacts BX4
For 4-pole CA4 and 2-pole CAT4 auxiliary contact blocks BX4-CA
For Contactors Aux. Contacts Code
no nC
AF 09…AF 16 1 1 VEM4
AF 26…AF 38
BX4
VeM4
BeA16-4
Ber38-4
BeY38-4
order Codes
order Codes
Connection Sets for reversing Contactors
Connection Sets for reversing Contactors
For Contactors Code
AF 09…AF 16 BER16-4
AF 26…AF 30 BER38-4
For line, Delta and Star Contactors interlock unit between Delta and Star Contactors Code
AF 09…AF 16 With or without BEY16-4
AF 26…AF 30 VM4 or VEM4 BEY38-4
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtionStock Status:normally stocked /Not normally stocked
14
Discount Code l10
14.5. Thermal Overload Relays
For Contactor Setting range (A) Code
A 9…A 40AL 9…AL 40
0.1…0.16 TA 25 DU0.16
0.16…0.25 TA 25 DU0.25
0.25…0.4 TA 25 DU0.4
0.4…0.63 TA 25 DU0.63
0.63…1.0 TA 25 DU1.0
1.0…1.4 TA 25 DU1.4
1.3…1.8 TA 25 DU1.8
1.7…2.4 TA 25 DU2.4
2.2…3.1 TA 25 DU3.1
2.8…4.0 TA 25 DU4.0
3.5…5.0 tA 25 DU5.0
4.5…6.5 TA 25 DU6.5
6.0...8.5 tA 25 DU8.5
7.5…11 TA 25 DU11
10…14 TA 25 DU14
13…19 TA 25 DU19
18…25 TA 25 DU25
24…32 TA 25 DU32
A 30… A40AL 30… AL 40
18…25 TA 42 DU25
22…32 TA 42 DU32
29…42 TA 42 DU42
A 50…A 75 AE 50…AE 75 AF 50…AF 75
18…25 TA 75 DU25
22…32 TA 75 DU32
29…42 TA 75 DU42
36…52 TA 75 DU52
45…63 TA 75 DU63
60…80 TA 75 DU80
A 95…A 110 AE 95…AE 110 AF 95…AF 110
29…42 TA 80 DU42
36…52 TA 80 DU52
45…63 TA 80 DU63
60…80 TA 80 DU80
65…90 TA 110 DU90
80…110 TA 110 DU110
A 145A 185 AF 145AF 185
66…90 TA 200 DU90
80…110 TA 200 DU110
100…135 TA 200 DU135
110…150 TA 200 DU150
130…175 TA 200 DU175
150…200 TA 200 DU200
A 210… A 300AF 210…AF 300
230…185 TA 450 DU185
165…235 TA 450 DU235
220…310 TA 450 DU310
280…400 TA 450 DU400
order Codes
thermal overload relays, Class 10A for A9…A 300, AF 50…300 Series
order CodesSeparate Mounting Kit
For overload relays Code
TA 25 DU </= 25 DB 25 25
TA 25 DU 32 DB 25 32
TA 42 DU, TA 75 DU, TA 80 DU DB 80
TA 110 DC, TA 200 DU DB 200
tA 25 DU
tA 80 DU
tA 42 DU
tA 110 DU
DB 25
tA 75 DU
14-641
14.5. Thermal Overload Relays Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
Discount Code l10
Discount Code l10
Discount Code l10
Discount Code C10
Discount Code C10
order Codes
order Codes
remote reset Coils
thermal overload relays, trip Class 10 for AF 09…AF 38 Series
For overload relays Code
TA 25, TA 450 DR25A-**
TA 42 DU 75 DRTA42-**
TA 110, TA 200 DRTA110-**
E 500, E 800 DRE500-**
** Reset coils 24V, 110V, 220-415V
For Contactor Setting range (A) Code
AF 09…AF 38 0.10…0.13 TF42-0.13
0.13…0.17 TF42-0.17
0.17…0.23 TF42-0.23
0.23…0.31 TF42-0.31
0.31…0.41 TF42-0.41
0.41…0.55 TF42-0.55
0.55…0.74 TF42-0.74
0.74…1.00 TF42-1.0
1.00…1.30 tF42-1.3
1.30…1.70 tF42-1.7
1.70…2.30 tF42-2.3
2.30…3.10 tF42-3.1
3.10…4.20 tF42-4.2
4.20…5.70 tF42-5.7
5.70…7.60 tF42-7.6
7.60…10.0 tF42-10
10.0…13.0 tF42-13
13.0…16.0 TF42-16
16.0…20.0 TF42-20
20.0…24.0 TF42-24
24.0…29.0 TF42-29
29.0…35.0 TF42-35
35.0…38.0/40.0 TF42-38
tF42
eF19
DB42
order Codes
electronic overload relays, trip Class 10,20,30 for AF 09…AF 38
Separate Mounting Kit
For overload relays Code
TF42 DB42
For Contactor Setting range (A) Code
AF 09…AF 38 0.10…0.32 EF19-0.32
0.30…1.00 EF19-1.0
0.8…2.70 EF19-2.7
1.90…6.30 EF19-6.3
5.70…18.9 EF19-18.9
AF 26…AF 38 9.0…30.0 EF45-30
15.0…45.0 EF45-45
order Codes
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtionStock Status:normally stocked /Not normally stocked
14
Discount Code l10
14.6. Manual Motor Starters
Setting range A...A ics 415V Code
0.10...0.16 50kA MS1160.16
0.16...0.25 50kA MS1160.25
0.25...0.40 50kA MS1160.4
0.40...0.63 50kA MS1160.63
0.63...1.00 50kA MS1161
1.00...1.60 50kA MS1161.6
1.60...2.50 50kA MS1162.5
2.50...4.00 50kA MS1164
4.00...6.30 50kA MS1166.3
6.30...10.00 50kA MS11610
8.00...12.00 25kA MS11612
10.00...16.00 16kA MS11616
16.00...20.00 10kA MS11620
20.00...25.00 10kA MS11625
25.00...32.00 10kA MS11632
Setting range A...A ics 415V Code
0.10...0.16 100kA MS1320.16
0.16...0.25 100kA MS1320.25
0.25...0.40 100kA MS1320.4
0.40...0.63 100kA MS1320.63
0.63...1.00 100kA MS1321.0
1.00...1.60 100kA MS1321.6
1.60...2.50 100kA MS1322.5
2.50...4.00 100kA MS1324.0
4.00...6.30 100kA MS1326.3
6.30...10.00 100kA MS13210
8.00...12.00 100kA MS13212
10.00...16.00 100kA MS13216
16.00...20.00 100kA MS13220
20.00...25.00 50kA MS13225
25.00...32.00 25kA MS13232
rated operational current [A] ics 415V Code
0.16 100kA MO1320.16
0.25 100kA MO1320.25
0.4 100kA MO1320.4
0.63 100kA MO1320.63
1 100kA MO1321.0
1.6 100kA MO1321.6
2.5 100kA MO1322.5
4 50kA MO1324.0
6.3 50kA MO1326.3
10 50kA MO13210
12 50kA MO13212
16 50kA MO13216
20 50kA MO13220
25 50kA MO13225
order Codes
order Codes
order Codes
MS 116 with thermal and electromagnetic trips
MS132 with thermal and electromagnetic trips, tripping class 10 (0.16 class 10A)
Mo132 with magnetic trip only
MS 116
MS 132
Mo 132
14-643
14.6. Manual Motor Starters Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
rated operationalpower 400VAC-3kW
Setting rangeA
Short circuitbreaking capacityics at 400V ACkA
ratedinstantaneousshort circuitcurrent setting ii A
Code
MS450 manual motor starter
15.8 28.0...40.0 25 520.00 MS450-40
22 36.0...45.0 25 585.00 MS450-45
22 40.0...50.0 25 650.00 MS450-50
MS495 manual motor starter
30 45.0...63.0 25 819.00 MS495-63
37 57.0...75.0 25 975.00 MS495-75
45 70.0...90.0 25 1170.00 MS495-90
55 80.0...100.0 25 1235.00 MS495-100
order Codes
MS450, MS495 - 28-100A with thermal and electromagnetic protectionManual motor starters (MMS) are protection devices for the main circuit. They combine motor control and protection in a single device. MMS are used mainly to switch motors manually ON/OFF and protect them and the installation fuse less against short circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short circuit condition, by switching off the motor within milliseconds.
Further features are the built in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three and single phase applications. The handle is lockable to protect against unauthorised changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, three phase busbars, power in feed blocks are available as accessories.
MS 450
MS 495
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.6. Manual Motor Starters Stock Status:
Normally stocked /Not normally stocked
14
Discount Code l10
rated control supply voltage V Frequency Hz Code
20...24 50/60 AA4-24
90...110 50/60 AA4-110
200...240 50/60 AA4-230
350...415 50/60 AA4-400
Description Auxiliary Contacts NO Auxiliary Contacts NC Code
1 1 HK4-11
Changeover HK4-W
Description Auxiliary Contacts NO Auxiliary Contacts NC Code
Max 1 piece 1 1 HKS4-11
Max 1 piece 2 0 HKS4-20
Max 1 piece 0 2 HKS4-02
Description Auxiliary Contacts NO Auxiliary Contacts NC Code
Separate signalling acc. UL508E1 NO + 1 NC for short circuit and1 NO + NC for general tripping, max. 2 pieces
2 2 SK4-11
rated control supply voltage V Frequency Hz Code
24 50/60 UA4-24
110/120 50/60 UA4-110
230/240 50/60 UA4-230
400/440 50/60 UA4-400
230/240 50/60 UA4-HK-230
400/440 50/60 UA4-HK-400
order Codes - Shunt trip units - mountable on the left
Order Codes - Auxiliary contacts - mountable on the front
Order Codes - Auxiliary contacts - mountable on the left
Order Codes - Auxiliary contacts - mountable on the right
order Codes - Undervoltage releases - mountable on the left
MS450, MS495 - AccessoriesMS450 and MS495 manual motor starters can be equipped with auxiliary contacts for lateral/front mounting, signalling contact for lateral mounting, undervoltage release and shunt trips. The accessories can be fitted wirig free and without tools. A variety of combinations is possible as required for the application. The auxiliary contacts change position with the main contacts. Undervoltage release are used for remote tripping of the manual motor starter especially for emergency stop circuits. Shunt trips release the MMS used for remotetripping.
HK4-11
HKS4-11
SK4-11
14-645
14.6. Manual Motor Starters Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
Accessories - MS116, MS132 and Mo132
Description Code
1 NO + 1 NC MS116HKF111
2 NO MS116HKF120
Description Code
1 NO + 1 NC MS116HK111
2 NO MS116HK120
2 NC MS116HK102
Description Code
1 NO + 1 NC MS116SK111
2 NO MS116SK120
2 NC MS116SK102
Description Code
1 NO + 1 NC MS132CK111
2 NO MS132CK120
2 NC MS132CK102
Description Code
2 NO MS116HKF120L
Description Code
24V, 50Hz MS116UA124
48V, 50Hz MS116UA148
60V, 50Hz MS116UA160
110V, 50Hz - 120V, 60Hz MS116UA1120
230V, 50Hz - 240V,60Hz MS116UA1230
400V, 50Hz MS116UA1400
415v, 50Hz - 480V, 60Hz MS116UA1415
Description Code
24V, 50/60Hz MS116AA124
110V, 50/60Hz MS116AA1110
200-240V, 50/60Hz MS116AA1230
350-415V, 50/60Hz MS116AA1400
Order Codes - MS116, MS132 and MO132 Auxiliary switches for front panel installation
Order Codes - Auxiliary switches, lateral attachment at right - MS116, MS/MO132
order Codes - Signal contact for general "tripped" signal, lateral attachment at right - MS116, MS/Mo132
order Codes - Signall contacts for short circuit alarm, mountable on the right - MS/Mo132 only
Order Codes - Auxiliary contacts with lead contacts, lateral attachment at right, also to use with undervoltage release,MS116 and MS/Mo132
order Codes - Undervoltage release, mountable on the left - MS116 and MS/Mo132
order Codes - Shunt trip, mountable on the left - MS116 and MS/Mo132
HKF111
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtion14.6. Manual Motor Starters Stock Status:
Normally stocked /Not normally stocked
14
Discount Code l10
Accessories
Description Code
For 2 devices without auxiliary switches PS1-2-0-65
For 3 devices without auxiliary switches PS1-3-0-65
For 4 devices without auxiliary switches PS1-4-0-65
For 5 devices without auxiliary switches PS1-5-0-65
For 2 devices with 1 auxiliary switch PS1-2-1-65
For 3 devices with 1 auxiliary switch PS1-3-1-65
For 4 devices with 1 auxiliary switch PS1-4-1-65
For 5 devices with 1 auxiliary switch PS1-5-1-65
For 2 devices with 2 auxiliary switches PS1-2-2-65
For 3 devices with 2 auxiliary switches PS1-3-2-65
For 4 devices with 2 auxiliary switches PS1-4-2-65
For 5 devices with 2 auxiliary switches PS1-5-2-65
Description Code
For 3 devices without auxiliary switches PS1-3-0-100
For 4 devices without auxiliary switches PS1-4-0-100
For 5 devices without auxiliary switches PS1-5-0-100
For 3 devices with 1 auxiliary switch PS1-3-1-100
For 4 devices with 1 auxiliary switch PS1-4-1-100
For 5 devices with 1 auxiliary switch PS1-5-1-100
For 3 devices with 2 auxiliary switches PS1-3-2-100
Description Code
Flat S1-M1-25
High S1-M2-25
order Codes - MS116 and MS132 Phase buses for cross wiring 63A, 690V
order Codes - MS116 and MS132 Phase buses for cross wiring 100A, 690V
Order Codes - Power infeed blocks, 63A, 690V, stranded 25mm2, flexible 16mm2
Manual motor starters Colour Code
MS116 MS132
• • Yellow/red IB132-Y
• • Grey/black IB132-G
Indication I-O-T and ON-OFF-T
Manual motor starters Colour Code
MS116 MS132
• • Yellow/red DMS132-Y
• • Grey/black DMS132-G
Indication I-O-T and ON-OFF-T
order Codes - enclosures iP65
Padlockable max. 3 padlocks with bail diameter 4...6.5mm
order Codes - Door mounting kit iP65
Padlockable max. 3 padlocks with bail diameter 4...6.5mm
14-647
14.6. Manual Motor Starters Stock Status:Normally stocked /Not normally stocked
14
Discount Code l10
Accessories
Description Code
Lock adapter - MS116 Only SA1
Padlock +2 keys - MS116, MS132, MO132 SA2
Locking device assembly MS116 Only SA3
(Adapter SA1 + padlock + 2 keys)
Note: MS132 only needs SA2
Description Code
Mini contactors B6/B7 BEA7116
Contactors A9/A12/A16 BEA16116
Contactors AL9/A12/A16 BEAL16116AL
Description Code
MSH MSHD shaft alignment ring MSH-AR
Description Code
Shaft length = 180mm (MS116, MS132, MO132, MS450, MS495) OXS6X180
Description Code
Black, MS116 only MSHDLB (1)
Yellow, MS116 only MSHDLY (1)
Black, MS132, MO132, MS450, MS495 MSHDLTB (2)
Yellow, MS132, MO132, MS450, MS495 MSHDLTY (2)
(1) Indication I-O and ON-OFF(2) Indication I-O-T and ON-OFF-T
Description Code
Coded driver for MS116, MS132, MS450, MS495 MSMN (1)
Uncoded driver for MS116, MS132, MS450, MS495 MSMNO (2)
(1) Coded - positioning of ON indication dependant on mounting orientation of the MS - use for vertically mounted MS.(2) Uncoded - positioning of ON indication independant of mounting orientation of MS
Description Code
Shaft length 32mm MSOX32 (1)
Shaft length 30mm MSOX30 (2)
(1) Permits correct orientation of external operator when MS is mounted vertically on panel(2) Permits correct orientation of external operator when MS is mounted horizontally on panel
order Codes - locking device for MS116 and MS132
order Codes - Direct adapter MS116
order Codes - Shaft alignment ring
order Codes - ShaftsFor selector type handles, shaft diameter 6mm. Shaft extension for door coupling driver.
order Codes - Selector type handles iP64Padlockable max. 3 with bail dia. 5-8, door interlock in ON position defeatable, use with 6mm OXS6... or driver shafts MSOX.
order Codes - Selector type handles iP64Coupling driver for use with 6mm OXS6... up to 180mm
order Codes - Driver shaftsMS116, MS132, MS450 and MS495 driver shaft - combination driver and shaft. Shaft diameter 6mm.
SA1
BeA16
MSHDlB
MSHDlY
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
14. Motor Control & ProteCtionStock Status:normally stocked /Not normally stocked
14
Discount Code C11
14.7. Enclosed Starters14.7.1. D.O.L. Starters
rated operating currentAC-3415VA
Motor PowerAC-3415 VkW
Code
Starters in iP65 plastic enclosures (1)
9 4 DYA 9-30 xxx
12 5.5 DYA 12-30 xxx
17 9 DYA 16-30 xxx
22 11 DRA 26-30 xxx
28 15 DRA 30-30 xxx
34 18.5 DRA 40-30 xxx
40 22 DRA 50-30 xxx
53 30 DRA 63-30 xxx
64 37 DRA 75-30 xxx
77 45 DRA 95-30 xxx
(1) Applicable up to 18.5kW, IP55 from 22-45kWOverloads to be purchased separately.xxx - Coil Voltages please see Page 14-630
order Codes - Undervoltage releases - mountable on the left
enclosed D.o.l. Starters - Starters for the control of three phase asynchronous motors, Direct on line (Dol)
D.A9...D.A16 Wiring Diagrams
• Operational voltage - up to 690V 50-60Hz• Starting time 1.5s maximum and switching frequency ≤ 15 starts with a load factor of 80% ≤ 30 starts/hour with a load factor of 50%• Ambient temperature ≤ 40°C around the enclosure
3 Phase Power
DYA 9-30
1 Phase Power Control
14-649
14.7. Enclosed Starters Stock Status:Normally stocked /Not normally stocked
14
Discount Code C11
14.7.2. YRA Star Delta Starters14.7.3. WRA Reversing Starters
rated operating currentAC-3415VA
Motor PowerAC-3415 VkW
Code
Starters in iP65 plastic enclosures
15.5 7.5 YRA 9-30 xxx
22 11 YRA 12-30 xxx
28 15 YRA 16-30 xxx
40 22 YRA 26-30 xxx
64 37 YRA 40-30 xxx
78 45 YRA 50-30 xxx
98 55 YRA 63-30 xxx
130 75 YRA 95-30 xxx
Plastic enclosures up to 22kW, above are metalFitted with E series electronic overloadsxxx - Coil Voltages please see Page 14-630
rated operating currentAC-3415VA
Motor PowerAC-3415 VkW
Code
Starters in iP65 plastic enclosures
9 4 WRB 6-30 xxx
12 5.5 WRA 12-30 xxx
17 9 WRA 16-30 xxx
28 15 WRA 30-30 xxx
Overloads to be purchased separatelyxxx - Coil Voltages please see Page 14-630
order Codes
order Codes
Starters for the control of three phase asynchronous motors, 6 wire connection
reversing Dol starters for the control of three phase asynchronous motors
• Operational voltage – up to 690 V, 50 or 60 Hz• Ambient temperature – < 40˚C around the enclosure
Maximum duty is dependant on:
• Switching frequency/hour, according to acceleration time and load factor.• Respecting the stated conditions enables utilisation of the starter without excessive overheating of the connections or nuisance tripping of the O/L relay
• Operational voltage 690 V, 50 or 60 Hz• Starting time 1.5 s maximum Switching frequency < 15 starts with a load factor of 80% or ≤ 30 starts/hour with a load factor of 50%• Ambient temperature - < 40˚C around the enclosure
YrA 26-30
WrA 12-30
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15.1.1. Micro
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
15. EnErgy ManagEMEnt
SEction 15
15-651
EnErgy ManagEMEnt
15. EnErgy ManagEMEnt 15-650Selection guide overview 15-65215.1. Power Meters 15-65415.2. Energy consumption Meters 15-65915.3. Multi-tenant Submetering 15-66015.4. Power Quality analyzers 15-66115.5. Power Quality revenue Meters 15-66515.6. Power Factor Manager 15-66615.7. Portable analyzers 15-66715.8. current Sensors 15-66815.9. current transformers 15-66915.10. Split-core current transformers 15-67315.11. current transducers 15-67515.12. current Switches 15-67615.13. Software 15-677
15.13.1. Power Analysis 15-67715.13.2. ExpertPower 15-678
15.14. on Site testing Services 15-679
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt
Discount Code L14
15
Selection Guide Overview Legend: = Option = Standard
Basic Masurements
Power Mesurements Energy Mesurement total Harm.
DistortionPower Harm.
individual Harmonics
Event, Data, Waveform Logging
(PQa) Power Quality
analysis
c19
2
15-6
66
• • • • • • • • • • • • • •
EM72
0
15-6
65
• • • • • • • • • 0.2S • • • • • • • 50 • • • • • • • • •
PM17
5
15-6
64
• • • • • • • • • 0.2S • • • • • • • 50 • • • • • • • •
PM29
6
15-6
63
• • • • • • • • • 0.2S • • • • • • • 40 • • • • • • •
FLaS
H 9
6
15-6
61
• • • • • • • 1 • • • 31
PM17
2 Se
ries
EH
15-6
58
• • • • • • • • • 0.2S • • • • • • • • • 40 • • • •
E • • • • • • • • • 0.2S • • • • • • • • • •
P • • • • • • • • • • •
BFM
136
15-6
60
• • • • • • • 0.5S
Impo
rt O
nly
• • • •
EM13
3
15-6
59
• • • • • • • • • 0.5S • • • • • • • 40 • • •
EM13
2
15-6
59
• • • • • • • • • 0.5S • • •
PM13
0/PM
135
EH
15-6
56 /
15-6
57 • • • • • • • • • 0.5S • • • • • 40 • • •
P • • • • • • • •
FEM
to
15-6
54
• • • • • • • • 1 • • • •
Page
refe
renc
e
V / A
/ H
z
Max
/Min
V /
A
V/A
Dem
ands
, Max
. Dem
ands
Neu
tral C
urre
nt
Unb
alan
ce V
/A
kW, k
VAR,
kVA
Max
kW
, kVA
R, k
VA
kW/k
VAR/
kVA
Dem
ands
, Max
. Dem
and
PF (P
ower
Fac
tor)
Accu
racy
Cla
ss
kWh,
kVA
Rh Im
port
& Ex
port,
kVA
h
Puls
e O
utpu
ts
Puls
e In
puts
TOU
Tar
iffs
THD
(Vol
tage
/ C
urre
nt)
TDD
(Tot
al D
isto
rtion
Dem
and)
K-Fa
ctor
Tota
l Har
mon
ic P
ower
s kW
, kVA
Tota
l Har
mon
ic E
nerg
ies
kWh,
kVA
h
Indi
v. H
arm
. (Vo
ltage
/Cur
rent
): up
to o
rder
Dire
ctio
nal H
arm
. Flo
ws
kW, k
VAR
Inte
rhar
mon
ic C
alcu
latio
n
Even
t Log
Data
Log
s
PQ L
og
Faul
t Log
Wav
efor
m L
og
Tim
e St
amps
Dips
/Sag
s, In
terru
ptio
ns, S
wel
ls R
ecor
ding
Tran
sien
ts R
ecor
ding
•
15-653
Selection Guide Overview
15
Legend: = Option = Standard
(PQa) Power Quality
analysis
Transformer calculation
i/o Programmable
Basic communications
Special communications g
PS communication Protocols
auxiliary inputs
additional Features
8 1* 1 • • • LED •
• • • • • • 4* 4+4* • • • • • • • 1 LCD •
• • • 2+2* 2* 2+2* 2* • • • • • • • LED
• 6 2* 12 • • • • • 1 1 LED
• LCD
2+2* 2* 2+2* 2* • • • • • • • LED
• 2+2* 2* 2+2* 2* • • • • • • • LED
• 2+2* 2* 2+2* 2* • • • • • • • LED
• • • • • LCD
1+2* 4* 2+4* • • • • • • LED
2* 4* 4* • • • • • • LED
2* 4* 4* • • • • • •
130
PLU
S: L
ED13
5: L
CD
2* 4* 4* • • • • • •
• • • • • LCD
Flic
ker
Sym
met
rical
Com
pone
nts
EN50
160
Repo
rts
Faul
t Cur
rent
Tran
sfor
mer
Cor
rect
ion
Tran
sfor
mer
/Lin
e Lo
ss C
ompe
nsat
ions
Digi
tal O
utpu
ts
Anal
og O
utpu
ts
Digi
tal I
nput
s
Anal
og In
puts
Anal
og O
utpu
t Exp
ande
r AX-
8
RS48
5
RS23
2
RS42
2
RS23
2/42
2/48
5
Dial
-up
Mod
em
Ethe
rnet
Por
t
USB
IR Profi
bus
DP
GSM
/GPR
S W
irele
ss M
odem
IRIG
-B (G
PS T
ime
Sync
hron
izatio
n)
Mod
bus
RTU
Mod
bus/
TCP
DNP3
.0
DNP3
/TC
P
ASC
II
AC C
urre
nt
AC V
olta
ge
DC V
olta
ge
Disp
lay
Back
-up
Pow
er S
uppl
y
Cap
acito
r Ban
k C
ontro
l
•
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt
15
15.1. Power Meters
FEMto 96 / FEMto D4
The Femto is a microprocessor based Energy analyzer with outstanding flexibility and accuracy designed to meet the most demanding applications of electrical parameters analyses and energy supply monitoring. The instrument combines the functions of a multimeter, power & energy meter and analyzer.
true-rMS
All the readings are “true-RMS” and they are obtained with a continuous sampling of the voltage and current waveforms in order to ensure the maximum metering accuracy of rapidly varying loads.
Simple to use
A graphic dot matrix LCD display with a led backlight and adjustable contrast allows the simultaneous reading of 4 parameters and their symbols with high visibility digits.
Versatile
The Femto is suitable for virtually all type of electrical grid, 3 and 4 wire, symmetrical and asymmetrical, balanced or unbalanced, single- and bi-phase, low tension and high tension, with 1, 2 or 3 CT’s as well as for 2 and 4 quadrant (import/export) measurement.
Digital and 4-20ma analogue outputs
The Femto comes complete with 1 x Digital Input and 2 x Digital Outputs which are optically insulated with programmable filter for input glitches. The digital input is set to operate for external pulse count of water meters and gas meters for example. Additionally it is equipped with 2 galvanically insulated analogue outputs (4-20 mA or 0-20 mA) providing an extremely high accuracy and signal stability.
alarms
The Femto comes with 2 programmable alarms. Each alarm can be selected to link to any one of the parameters available, for example, either as a minimum and/or as a maximum.
Serial communication
The Femto is equipped with an opto insulated and over-voltage protected RS485 serial communication port. The protocol is a fully compliant with Modbus-RTU suitable for communication with PLCs and with SCADA systems.
Power supply The Femto is equipped with 230-240Vac power supply.
FEMto 96 FEMto D4
15-655
15.1. Power Meters Stock Status:Normally stocked /Not normally stocked
15
Discount code L4
readings
order codes
Parameter type L1 L2 L3 n ∑ P range
Voltage UL-N X X X X 20.0V...400kV
UL-L X X X X
UL-N MAX (1) X X X
UL-L MAX (1) X X X
UL-N MIN (1) X X X
UL-L MIN (1) X X X
current I X X X X X 10mA...10kA
I MAX (1) X X X
IAVG THERM (2) X X X
IMD THERM (2) X X X
Power Factor PF X X X X 0.00ind...1.00...0.00cap
Frequency f X 45...65Hz
Harmonic Distortion THD-UL-N X X X X 0...199.9%
THD-UL-L X X X X
THD-I X X X X
active Power P X X X X ± 0.00…1999 MW
Pm (3) X
PMD (3) X
PMAX (1) X X X
reactive Power Q IND X X X X ± 0.00…1999 Mvar
Q CAP X X X X
Qm IND (3) X
Qm CAP (3) X
QMD IND (3) X
QMD CAP (3) X
apparent Power S X X X X ± 0,00…1999 MVA
Sm (3) X
SMD (3) X
temperature T (°C e F) (4) X -10…+50 °C
Life time h (1/100 h) X X 0.01…99.999.99
active Energy Ea IMP (5) X X X X X 0,1 kWh…99.999,9 MWh
Ea EXP (5) X X
reactive Energy Er IND IMP (5) X X X X X 0.1 kvarh…99.999.9 Mvarh
Er CAP IMP (5) X X
Er IND EXP (5) X X
Er CAP EXP (5) X X
apparent Energy Es IMP (5) X X 0.1kVAh…99.999.9 MVAh
Es EXP (5) X X
Pulse counter CNT X X
(1) Absolute value (mean over 10 cycles - example: 200ms at 50Hz). (2) Mean value (rolling average) over the integration time (1.. 60 min. programmable). (3) Import /Export mean value (rolling average) over the integration time (1.. 60 min. programmable). (4) Internal temperature of the microprocessor. (5) Import/Export energies displayed as 9 digits in floating-point readings; internal energy metering performed with 0,1 Wh minimum resolution and 99.999.999,9999 kWh maximum energy count before rollover.
Description Series Mounting code
Built-in RS485 serial port (Modbus Protocol), 1 digital input & 2 isolated digital outputs (programmable for pulse or alarm transmission or as remote output devices)
Femto 96 Panel 96x96mm PFa6c11-12
Femto D4 DIN-Rail PFa6411-12
Built-in RS485 serial port (Modbus protocol), 2 active 4 to 20mA analog outputs
Femto 96 Panel 96x96mm PFa6c11-62
Femto D4 DIN-Rail PFa6411-62
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.1. Power Meters
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
PM130-Plus Multi Function Power Meters class 0.5
order codes
type Description code 1
Power Version
LED Display. Measures Volts, Amps, Vars, VA, PF, Hz, Phase Rotation, Neutral Current, Voltages and Currents Unbalance, Max. Demand (Amps, Watts), Min/Max Values, nominal voltage range of 0-690V L-L, One communication port RS485, protocol: ASCII, MODBUS and DNP 3.0 Level 2.Memory 59KB for Event/Data Logging, Date/Time stamping.
PM130P-PLUS
Energy and Harmonic Version
All above features plus: THD and individual Harmonics to 40 for Voltages and Currents, TDD and K-Factor for Currents, Neutral Current, Voltages and Currents Unbalance, Energy (Import/Export) - kWh, kVAh, kvarh and Demand (Max. Accum, Sliding, Projected) - kW, kVA, kvar, Energy Registers, Max Demand Registers. Harmonic Measurements - synthesized voltage and current waveforms (via PAS software).
PM130EH-PLUS
Energy Only All above features without Total THD and without Individual Harmonics PM130E-PLUS
options code 2
current inputs
5 Ampere 5
1 Ampere 1
5A split core remote high accuracy current sensor (HACS)
RS5
High Accuracy Current Sensors (HACS).Requires ordering of 3 HACS
HACS
calibration at Frequency
50 Hz 50HZ
Power Supply
85-265V AC and 85-290V DC acDc
9.5-18V DC 1DC
18.5-58V DC (24VDC, 48VDC) 23DC
communication Protocol
Modbus and DNP 3.0 -
Modbus and IEC 60870-101/104 870
Mounting
Panel Mount (standard) -
DIN Rail Mounting DIN
options code 3
Expansion Module (Max. 1 module per instrument, can be ordered separately)
4 Analog Outputs: 0-20mA AO2
4 Analog Outputs: 4-20mA AO4
4 Digital Inputs (Dry Contact) / 2 Relay Outputs 250V / 5A AC Dior
Communication: Ethertnet (TCP/IP) EtH
Communication: PROFIBUS PRO
Communication: RS232 RS232
Example to build a code number:
code 1 code 2 code 3
PM130P-PLUS 5 50HZ ACDC - - DIOR
15-657
15.1. Power Meters
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
order codes
type Description code 1
Power Version
Measures Volts, Amps, Vars, VA, PF, Hz, Phase Rotation, Neutral Current, Voltages and Currents Unbalance, Max. Demand (Amps, Watts), Min/Max Values, nominal voltage range of 0-690V L-L, One communication port RS485, protocol: ASCII, improved MODBUS and DNP 3.0 Level 2. Bright LCD display standard. Memory 120KB
PM135P
Energy and Harmonic Version
All above features plus: THD and individual Harmonics to 40 for Voltages and Currents, TDD and K-Factor for Currents, Neutral Current, Voltages and Currents Unbalance, Energy (Import/Export) - kWh, kVAh, kvarh and Demand (Max. Accum, Sliding, Projected) - kW, kVA, kvar, Energy Registers, Max Demand Registers. Harmonic Measurements - synthesized voltage and current waveforms (via PAS software).
PM135EH
Energy Only All above features without Total THD and individual Harmonics PM135E
PM135 Multi Function Power Meters class 0.5
options code 2
current inputs
5 Ampere 5
1 Ampere 1
5A split core remote high accuracy current sensor (HACS)
RS5
High Accuracy Current Sensors (HACS).Requires ordering of 3 HACS
HACS
calibration at Frequency
50 Hz 50HZ
Power Supply
85-265V AC and 85-290V DC acDc
9.5-18V DC 1DC
18.5-58V DC (24VDC, 48VDC) 23DC
communication Protocol
Modbus and DNP 3.0 -
Modbus and IEC 60870-101/104 870
Mounting
Panel Mount (standard) -
DIN Rail Mounting DIN
options code 3
Expansion Module (Max. 1 module per instrument, can be ordered separately)
4 Analog Outputs: 0-20mA AO2
4 Analog Outputs: 4-20mA AO4
4 Digital Inputs (Dry Contact) / 2 Relay Outputs 250V / 5A AC Dior
Communication: Ethertnet (TCP/IP) EtH
Communication: PROFIBUS PRO
Communication: RS232 RS232
Example to build a code number:
code 1 code 2 code 3
PM135P 5 50HZ ACDC - - DIOR
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.1. Power Meters
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
PM172 Multifunction Power Meters class 0.2
order codes
type Description code 1
Power Version
Measures Volts, Amps, Vars, VA, PF, Hz, Phase Rotation, Max. Demand (Amps, Watts), Min/Max Values, Harmonics per phase (%THD Voltage and %TDD Current), Two status inputs, Two relayoutputs, PLUS Two communication ports for simultaneous use RS232/422 and RS485 in ASCII, improved MODBUS and DNP 3.0 Level 2. Bright LED display standard.
PM172P-N
Energy Version
All “Power Version” features plus: Energy (Import/Export) - kWh, kVAh, kvarh and Demand (Max. Accum, Sliding, Projected) - kW, kVA, kvar, Time Of Use (TOU) - Energy Registers, Max Demand Registers.1MB Internal Memory for Data Logging and Energy Management.
PM172E-N
Energy and Harmonic Version
All “Energy Version” features plus: Harmonic Measurements - synthesized voltage and current waveforms (via PAS software) and total harmonic powers and energies, Fast Waveform Recordings provided for waveform capture and logging on different events. Along with the disturbance monitor, it allows for capture and recording of various types of disturbances with a duration from 1ms to 10sec - transients, outages, sags, surges and deviations in voltage level.
PM172EH-N
RPM072 Transducer version (without display / remote display) of the PM172E RPM072
Example to build a code number:
code 1 code 2
PM172P-N U 5 50HZ ACDC DIO -
options code 2
Voltage inputs
690V AC Nominal Voltage Input
-
120V AC Nominal Voltage Input
U
current inputs
5 Ampere 5
1 Ampere 1
5A split core remote high accuracy current sensor (HACS)
RS5
High Accuracy Current Sensors (HACS). Requires ordering of 3 HACS
HACS
calibration at Frequency
50 Hz 50HZ
Power Supply
85-265V AC and 88-290V DC ACDC
9.6-19V DC 1DC
19-37V DC 2DC
37-72V DC 3DC
i/o Module (max. 1 per device)
2 Digital Input / 2 Digital Output (total 4DI/4DO)
DIO
2 Analog Output: 0-20mA AO2
2 Analog Output: 4-20mA AO4
2 Analog Input: 0-20mA AI2
2 Analog Input: 4-20mA AI4
communication
Standard Communications RS232/422/485
-
Ethertnet (TCP/IP) ETH
PROFIBUS PRO
15-659
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
15.2. Energy Consumption Meters
order codes
type Description code 1
EM132AU
Energy Load Management Meter - Measures Volts, Amps, Vars, VA, PF, Hz, Phase Rotation, Neutral Current, Voltages and Currents Unbalance, Max. Demand (Amps, Watts), Energy (Import/Export) - kWh, kVAh, kVArh and Demand (Max. Accum, Sliding, Projected) - kW, kVA, kVAr, Energy Registers, Max Demand Registers, Min/Max Values, nominal voltage range of 0- 690V L-L, One communication port RS485, protocol: ASCII, improved MODBUS and DNP 3.0 Level 2. Wide temperature LCD characters display and battery backup for real time clock.
EM132aU
EM133AU
Energy Meter - All above features plus: THD and individual Harmonics to 40 for Voltages and Currents, TDD and K-Factor for Currents, Neutral Current, Voltages and Currents Unbalance and Time Of Use (TOU). Harmonic Measurements - synthesized voltage and current waveforms (via PAS software).Includes 2 digital inputs, relay output and Infra Red (IR) port.
EM133aU
EM133AR
Residential Energy Meter - Same as EM133, plus display of current and previous day, week, month and quarter of all energy, hot and cold water and gas with customized pulse input labels and customized decimal point (e.g., “kL” or “M3” for water). The information is stored using 8 energy registers and is available via the comm’s.Note: Only Single Phase or 4 wire connection and Modbus protocol.
EM133AR
EM132/EM133 class 0.5 Energy Meter
options code 2
current inputs
5 Ampere 5
1 Ampere 1
Direct current measurement up to 100A 100
High Accuracy Current Sensors (HACS).Requires ordering of 3 HACS
HACS
calibration at Frequency
50 Hz 50HZ
Power Supply
40-300V AC/DC acDc
communication Protocol
Modbus and DNP 3.0 -
Modbus and IEC 60870-101/104 870
options code 3
Expansion Module (Max. 1 module per instrument, can be ordered separately)
Analog Outputs: 0-20mA AO2
Analog Outputs: 4-20mA AO4
Digital Inputs (Dry Contact) / Relay Outputs 250V / 5A AC Dior
Communication: Ethertnet (TCP/IP) EtH
Communication: PROFIBUS PRO
Communication: RS232 RS232
Example to build a code number:
code 1 code 2 code 3
EM132AU 5 50HZ ACDC - DIOR
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt
Discount Code L14
Stock Status:normally stocked /Not normally stocked
15
15.3. Multi-Tenant Submetering
order codes
type Description code 1
BFM136 - Branch Feeder Monitor
36 channel energy meter, accuracy class 0.5S according to IEC62053-221 Standard RS485 communication port1 Optional communication port - COM22 row 16 character LCD DisplayMeasurement Voltage (115/230/277) 88-320 VAC
BFM136
BFM136 - Branch Feeder Monitor
options code 2
Frequency
50HZ 50HZ
coM2 Second communication Port
None -
RS232 R2
RS485 R4
Ethernet (TCP/IP) EtH
Mounting
Wall Mount (standard) -
DIN Rail Mounting D
Seal
No Terminal Seal (Standard) -
With Terminal Seal S
note: RF module and accessories are available in certain regions only - please consult your local supplier
Example to build a code number:
code 1 code 2
BFM136 50HZ - D -
15-661
15
15.4. Power Quality Analyzers
Flash 96
The Flash 96 is a microprocessor based Energy analyzer with outstanding flexibility and accuracy designed to meet the most demanding applications of energy supply monitoring in the industrial environment. All the readings are “true-RMS” and they are obtained with a continuous sampling of the voltage and current waveforms in order to ensure the maximum metering accuracy of rapidly varying loads (e.g. spot welding) as well as the instrument’s suitability for energy quality supervision functions.
The Flash 96 is a revolutionary instrument that may be upgraded after installation to new user needs and to its installation parameters. Two expansion ports make it possible to select the data transmission mode by means of a simple connection of optional modules (RS232, RS485, Analogue, I/O) while the instrument architecture is designed to enable the implementation, in the field, at any time, of the harmonics analyses by means of simple code entries operated via front key board.
Simple to use
A large high-contrast LCD display with backlight allows the simultaneous reading of 4 parameters and their symbols with high visibility digits. A bar-graph indicator supplements the reading mode of 3 parameters in analogue format also. 9 keys, with clear indication of their function, make the instrument use simple and intuitive. A Led indicator, pulsing with a frequency proportional to the active import power, is also provided on the front panel for field calibration verification by means of external optical devices.
Versatile
The Flash 96 is suitable for virtually all type of electrical grid, 3- and 4 wire, symmetrical and asymmetrical, balanced or unbalanced, single- and bi-phase, low tension and high tension, with 1, 2 or 3 CT’s as well as for 2 and 4 quadrant (import/export) measurement. A simple keyboard programming allows the setting of all the operational parameters such as grid type, LV/HV, CT and VT ratios (free setting) integration time (1-60 min), alarms (thresholds, delays, hysteresis), digital outputs and configuration of the optional modules that may be connected.
alarms
The Flash 96 is equipped with 2 programmable alarms offering the maximum configuration flexibility for adapting to the most diverse requirements.
Serial communication
The Flash 96 supports an RS485 or RS232 serial communication by means of optional add-on modules. The protocol is the Modbus RTU or ASCII, suitable for communication with PLCs and with SCADA systems.
Digital outputs
The Flash 96 is equipped with two programmable optically isolated transistor outputs rated 27Vdc 27mA per DIN 43864 standards.
Hardware Expansions (optional modules)
The Flash 96 is fitted with 2 expansion sockets for the connection of external expansion modules supporting specific communication functions (serial, analogue, digital).
Firmware Expansions (options)
The instrument firmware already embeds the possibility of additional metering possibilities like the FFT harmonics analyses that may be implemented at any time by the entry, via front keyboard, of a unique PUK code that may be ordered separately
FLaSH 96
FLaSH D6
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.4. Power Quality Analyzers Stock Status:
Normally stocked /Not normally stocked
15
Discount code L4
order codes
Description Series Mounting code 1
Over 60 readings including phase THD-I, THD-U, average peak import / export powers, 2-4 quadrant energies (Ea, Er). 85-265VAC / 100-374VDC power supply
FLASH 96 Panel 96x96mm PFa2c10-82
FLASH D6 DIN-Rail PFE430-00
readings
Flash 96 with FFt harmonics option or Flash 96 H
Parameter type L1 L2 L3 ∑ range
Voltage UL-N X X X X 20.0V...400kV
VL-L X X X X
current I-Phase X X X 10 mA…10,0 kA
I-Neutral X
Power Factor PF X X X X 0.00ind...1.00…0.00cap
Frequency Hz X 45...65Hz
Harmonic Distortion THD-V X X X X 0…199.9%
THD-I X X X X
Life time H (1/100h) X 0.01…99.999.99 hours
active Power P X X X X ± 0,00…1999 MW
Pm (1) X
Pmd (1) X
reactive Power Q X X X X ± 0,00…1999 Mvar
Qm-ind (1) X
Qm-cap (1) X
Qmd-ind (1) X
Qmd-cap (1) X
apparent Power S X X X X ± 0,00…1999 MVA
Sm (1) X
Smd (1) X
active Energy KWh (2) X 0.1 kWh…99.999.9 MWh
reactive Energy Kvarh-ind (2) X 0.1 kvarh…99.999.9 Mvarh
Kvarh-cap (2) X
apparent Energy KVAh (2) X 0.1kVAh…99.999.9MVAh
Parameter type L1 L2 L3 ∑ range
FFT Harmonics H Voltage X X X Value (H01),% (H02-H31)
H Current X X X Value (H01),% (H02-H31)
H Power & direction X X X Value (H01),% (H02-H31)
(1) Mean value over the integration time (1.. 60 min. programmable)(2) Energies are displayed as 6 digit floating-point readings; internal energy metering is performed with 0,1 Wh minimum resolution and99.999.999,9999 kWh maximum energy count before rollover.
order codes
Description For Use With code 1
RS485 Flash 96 PFE420-00
RS232 PFE421-00
2 x 4 to 20mA programmable outputs PFE422-00
2 x Digital inputs + 2 x Relay outputs (30VDC @ 2A) PFE425-00
Adaptor DIN/96 – Cable for use of “DIN” options into “96”meters PCADL00-00
RS485 Flash D6 PFE830-00
RS232 PFE825-00
2 x 4 to 20mA programmable outputs PFE835-00
Adaptor DIN/96 – Cable for use of “96” options into “DIN” meters PCACL00-00
FFT Harmonics readings option that enables the FFT harmonics readings per phase of U, I & P up to 31st order + direction of flow
Flash 96 & Flash D6 PFSW399-00
Flash 96
FLaSH 96
FLaSH D6
15-663
15.4. Power Quality Analyzers
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
PM296 Power Quality analyzer
order codes
type Description code 1
PM296
PM296 Power Quality analyzer and revenue Meter class 0.2sBasic Measures: Volts, Amps, Watts, Vars, VA, PF, Hz, Voltage and Current Unbalance, Nuetral Current, Auxilliary: AC Current and DC VoltageDemands: Amps, Volts, VA, Export/Import: Watts, VarsMin/Max: Volts, Amps, Hz, kW, KVAr, KVAEnergy: Vh, Ah, KVAh, Export/Import: KWh, KVArh, Time of Use (TOU)- Energy and Max. Demand RegistersPower Quality: Voltage Disturbance, Phase Angles, 6-Waveform Capture (3-Current, 3-Voltage)Harmonics: Voltages and Currents THD per Phase, Current TDD and K-FactorHarmonic Values: Amps, Volts, KW, KVAr, PF up to 63rd. Programmable Min/Max Log for Harmonic Valuesoutputs: 6 programmable (Pulse, Alarms, Events) Relay 5A, 250VAC, 2 programmable Analog Outputs (+1mA, 0-20mA, 0-1mA, 4-20mA)inputs: 12 Digital Inputs (Voltage free for dry contact sensing), DC-Voltage input 0-300VDC, AC- Current input 1A or 5Acommunication: 2 comm. ports RS232/422/485 Protocols ASCII, MODBUS, DNP3.0
PM296
Example to build a code number:
code 1 code 2
PM296 U 5 50HZ ACDC - AI20 N1
options code 2
Voltage inputs
690V AC Nominal Voltage Input
-
120V AC Nominal Voltage Input
U
current inputs
5 Ampere 5
1 Ampere 1
Frequency
50 Hz 50HZ
Power Supply
85-265V AC and 88-290V DC ACDC
9.6-19V DC 1DC
19-37V DC 2DC
37-72V DC 3DC
analog output
No analog output -
Two programmable analog outputs 2AP
analog Voltage input Dc
0.4 - 20 V AI20
2 - 100 V AI100
6 - 300 V AI300
neutral current input
Neutral Current 1Amp Input (Standard with 1CT)
N1
Neutral Current 5Amp Input (Standard with 5CT)
N5
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.4. Power Quality Analyzers
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
PM175 Power Quality Meters with Waveform capture class 0.2 (iEcStandards)
order codes
type Description code 1
PM175 Power Quality Analyzer
Measures Volts, Amps, Vars, VA, PF, Hz, Phase Rotation, Max. Demand (Amps, Watts), Min/Max Values, Neutral Current, Voltages and Currents Unbalance. Energy (Import/Export) - kWh, kVAh, kvarh and Demand (Max. Accum, Sliding, Projected) - kW, kVA, kvar, Time Of Use (TOU) - Energy Registers, Max Demand Registers.Two status inputs, Two relay outputs, Two communication ports for simultaneous use RS232/422 and RS485 in ASCII, improved MODBUS and DNP 3.0 Level 2, 1MB Internal Memory for Data Logging and Energy Management. Bright LED display standard.Harmonic Measurements - THD and individual Harmonics to 50 for Voltages and Currents, TDD and K-Factor for Currents, harmonic powers and energies. Fast Waveform Recordings provided for waveform capture and logging on different events. It allows capture and recording of various types or power quality events such as transients (down to 1ms), dups, overvoltages and interruptions.EN50160 or GOST13109 compliance statistics and power quality recorder (via PAS software).Flicker measurement according to IEC 61000-4-15.
PM175
PM175 with 5.7” touchscreen graphic color display PM175-TFT
Transducer version (without display / remote display) of the PM175 RPM075
Example to build a code number:
code 1 code 2
PM175 U 5 50HZ ACDC DIO -
options code 2
Voltage inputs
690V AC Nominal Voltage Input
-
120V AC Nominal Voltage Input
U
current inputs
5 Ampere 5
1 Ampere 1
Lindsey sensors -
5A split core remote high accuracy current sensor (HACS)
RS5
High Accuracy Current Sensors (HACS). Requires ordering of 3 HACS
HACS
calibration at Frequency
50 Hz 50HZ
Power Supply
85-265V AC and 88-290V DC ACDC
9.6-19V DC 1DC
19-37V DC 2DC
37-72V DC 3DC
i/o Module (max. 1 per device)
4 Digital Input / 4 Digital Output DIO
2 Analog Output: 0-20mA AO2
2 Analog Output: 4-20mA AO4
2 Analog Input: 0-20mA AI2
2 Analog Input: 4-20mA AI4
communication
Standard Communications RS232/422/485
-
Ethertnet (TCP/IP) ETH
PROFIBUS PRO
15-665
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
15.5. Power Quality Revenue Meters
EM720 eXpertMeter
order codes
type Description code 1
Basic Model
EM 720 - Measures Volts, Amps, Vars, VA, PF, Hz, Phase Rotation, Max. Demand (Amps, Watts), Min/Max Values, Neutral Current, Voltages and Currents Unbalance. Energy (Import/Export) - kWh, kVAh, kvarh and Demand (Max. Accum, Sliding, Projected) - kW, kVA, kvar, Time Of Use (TOU) - Energy Registers, Max Demand Registers.Includes 4 digital inputs for synchronization/status/counter functions with 1ms sampling rate. 8MB non-volatile memory for data logging, power and energy management. Harmonics and interharmonics measurements according to IEC 61000-4-7. Waveform recording for waveform capture and logging on different events. Flicker measurement according to IEC 61000-4- 15. eXpertMeter EM720 includes the following capabilities in one device:• Precise Energy/Revenue meter (IEC 62053 Class 0.2S)• Advanced Power Quality Analyzer (IEC 61000-4-30)• Transient Recorder (EM720T)
EM720
Transient Power Master
Transducer version (without display / remote display) of the PM175 EM720T
Example to build a code number:
code 1 code 2
EM720 480V 5 50HZ - XM IRIG
options code 2
Voltage inputs
480V AC (L-L) 480V
120V AC (L-L) 120V
current inputs
5 Ampere 5
1 Ampere 1
calibration at Frequency
50 Hz 50HZ
rechargeable Battery
Without Battery -
Memory
Standard Memory - 8MB -
Expanded Memory - 16MB XM
optional Modules (see notes)[1] Default communication: IRIG-B, IR and RS-232/485
IRIG
[1] Default communication plus USB, Ethernet and 2nd RS232/485 (2 cards)
IRIG-ETH
[1] Default communication plus USB, Ethernet and 2nd RS232/485 with IEC 61850 protocol support (2 cards)
IRIG-ETH-850
[1] Replacing the IRIG-B on the default communication card with USB and Ethernet
ETH
[1] Replacing the IRIG-B on the default communication card with USB, Ethernet and IEC 61850 protocol support
ETH-850
[2] 2 DI/2 Relay Output (Form C) 250VAC/5A
DIOR
[3] Aux. PS: 88-265V AC and 90-290V DC
AUX-ACDC
[3] Aux. PS: 24 VDC AUX-24
Notes: Maximum 3 cards per device, with the following limitations: [1] Select only one of the [1] options [2] Maximum 2 I/O modules per device [3] Maximum 1 Aux. Power Supply module per device
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt
Discount Code L14
Stock Status:normally stocked /Not normally stocked
15
15.6. Power Factor Manager
c192
order codes
type Description code 1
C192PF8
C192PF8 Power Factor Manager controls up to 8 capacitor banks, Multipurpose switches. Measures and displays up to 65 parameters and has 8 programmable relays for alarms/setpoints/pulses, 1 digital input for synchronization or status, and one optional analog output. Communication is available (RS-485) with ASCII/Modbus protocols. The PM190 features a triple bright LED display plus LED indicators for alarm and communications, as well as a LED bar-graph indicating percent load. Also offered is a programmable automatic scrolling feature. Phase rotation indication is provided.
C192PF8
Example to build a code number:
code 1 code 2
C192PF8 U 5 50HZ ACDC - -
options code 2
Voltage inputs
690V AC Nominal Voltage Input
-
120V AC Nominal Voltage Input
U
current inputs
5 Ampere 5
1 Ampere 1
Frequency
50 Hz 50HZ
Power Supply
85-265V AC and 88-290V DC (Standard)
ACDC
9.6-19V DC 1DC
19-37V DC 2DC
37-72V DC 3DC
communications
RS485 (Standard) -
RS232 R2
analog output
No Analog Output -
0-20mA A2
4-20mA A4
15-667
Discount Code L14
Stock Status:Normally stocked /Not normally stocked
15
15.7. Portable Analyzers
EDL-Xr
order codes
type Description code 1
EDLXR172
EDL-XR “Portable Event & Data Logger Extended Range”Includes PM172 W/Bright LED’s.Adds the ability to measure low currents (5A nominal) using clamps. + Battery Backup. Current Input 1 A ONLYIncludes 4 voltage cables and bag for accessories.
EDLXR172
EDLXR175
EDL-XR “Portable Event & Data Logger Extended Range”Includes PM175 W/Bright LED’s.Adds the ability to measure low currents (5A nominal) using clamps. + Battery Backup. Current Input 1 A ONLYIncludes 4 voltage cables and bag for accessories.
EDLXR175
Example to build a code number:
code 1 code 2
EDLXR172 200A 50HZ -
options code 2
current calmps
200A / 2VAC - set of three 200A
Flex Sensor 30A / 300A / 3000A - set of three FLEX
Frequency
50 Hz 50HZ
communications
Standard RS232/485 -
Expanded Memory - 16MB ETH
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt
Discount Code L14
Stock Status:normally stocked /Not normally stocked
15
15.8. Current Sensors
HacS - Series
order codes
Description code
100A Solid Core High Accuracy Current Sensor (HACS), Φ12mm hole CS1
100A Solid Core High Accuracy Current Sensor (HACS), Φ23mm hole CS1L
100A Split Core High Accuracy Current Sensor (HACS), Φ16mm hole CS1S
200A Split Core High Accuracy Current Sensor (HACS), 23×33mm hole CS2SL
400A Solid Core High Accuracy Current Sensor (HACS), Φ26mm hole CS4
400A Split Core High Accuracy Current Sensor (HACS), 23×33mm hole CS4S
800A Solid Core High Accuracy Current Sensor (HACS), 100×32mm / Φ62mm hole CS8
800A Split Core High Accuracy Current Sensor (HACS), 80×50mm hole CS8S
1200A Split Core High Accuracy Current Sensor (HACS), 80×121mm hole CS12S
SATEC’s Properiatary High Accuracy Current Sensors (HACS) are designed to be used with our HACS meters and analyzers.SATEC current sensors have several benefits over CTs:
• High accuracy• Wide bandwidth (for harmonics measurement)• Safe to use - no need for shorting CT links/bars• Standard cable length 2.5 metres.• Cable Length canextended up to 200m without performance reduction using 1.5mm2 cable.• For standard 3 phase meter/analyzer, please order 3 Current Sensors. For BFM specify quantity, up to 36 sensors per BFM
15-669
Stock Status:Normally stocked /Not normally stocked
15
Discount code c4
15.9. Current Transformers
current transformerstat022 Series - order codes
tac032 Series - order codes
cable Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1 cL 3
ø 22mm 20 x 5mm 40/5A 1.2 tat022040X05
50/5A 1.2 TAT022050X05
60/5A 1.5 tat022060X05
80/5A 1 2.5 tat022080X05
100/5A 1.5 3 tat022100X05
120/5A 2 4 TAT022120X05
150/5A 1 3 5 tat022150X05
200/5A 1 1.5 2 tat022200X05
250/5A 1 1.5 3 tat022250X05
300/5A 1 2 4 tat022300X05
400/5A 1.5 3 5 tat022400X05
500/5A 2 4 6 TAT022500X05
600/5A 2.5 5 7 TAT022600X05
cable Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1 cL 3
ø 24mm 32 x 10mm 40/5A 1 TAC032040X05
50/5A 1.2 TAC032050X05
60/5A 1.5 TAC032060X05
80/5A 1 2.5 TAC032080X05
100/5A 1 2 3 tac032100X05
120/5A 2 3 4 TAC032120X05
150/5A 2.5 3 5 tac032150X05
200/5A 3 5 8 tac032200X05
250/5A 4 7 10 tac032250X05
300/5A 6 10 12 tac032300X05
400/5A 10 12 12 tac032400X05
500/5A 12 15 15 tac032500X05
600/5A 12 15 15 TAC032600X05
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.9. Current Transformers Stock Status:
Normally stocked /Not normally stocked
15
Discount code c4
tac040 Series - order codes
cable Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1 cL 3
ø 32mm 40 x 10mm 100/5A 1.5 4 TAC040100X05
120/5A 2 4 TAC040120X05
150/5A 1.5 3 5 TAC040150X05
200/5A 2 4 6 TAC040200X05
250/5A 3 6 9 TAC040250X05
300/5A 5 8 12 tac040300X05
400/5A 10 15 20 tac040400X05
500/5A 12 20 25 tac040500X05
600/5A 15 20 25 tac040600X05
800/5A 18 25 30 TAC040800X05
1000/5A 20 25 30 TAC0401K0X05
15-671
15.9. Current Transformers Stock Status:Normally stocked /Not normally stocked
15
Discount code c4
tat061 Series - order codes
tat084 Series - order codes
cable Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1 cL 3
ø 51mm 61 x 31mm 250/5A 3 5 TAT061250X05
300/5A 4 6 TAT061300X05
400/5A 2 6 10 TAT061400X05
500/5A 4 10 12 TAT061500X05
600/5A 6 15 18 TAT061600X05
800/5A 8 15 20 tat061800X05
1000/5A 10 20 30 tat0611K0X05
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1
62 x 34mm 200/5A 2 4 TAT084200X05
250/5A 3 6 TAT084250X05
300/5A 4 8 TAT084300X05
400/5A 5 10 TAT084400X05
500/5A 6 15 TAT084500X05
600/5A 8 20 tat084600X05
800/5A 10 20 tat084800X05
1000/5A 15 25 tat0841K0X05
1200/5A 20 40 TAT0841K0X05
1500/5A 25 50 TAT0841K2X05
2000/5A 30 60 TAT0841K5X05
2500/5A 40 80 TAT0842K5X05
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.9. Current Transformers Stock Status:
Normally stocked /Not normally stocked
15
Discount code c4
tat125 Series - order codes
tat126 Series - order codes
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1
127 x 55mm 400/5A 2 7 TAT125400X05
500/5A 4 10 TAT125500X05
600/5A 6 12 TAT125600X05
800/5A 12 16 TAT125800X05
1000/5A 15 22 TAT1251K0X05
1200/5A 15 30 TAT1251K2X05
1500/5A 22 35 TAT1251K5X05
2000/5A 27 40 TAT1252K0X05
2500/5A 30 50 tat1252K5X05
3000/5A 35 50 tat1253K0X05
4000/5A 35 50 TAT1254K0X05
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1
105 x 38mm 400/5A 3 5 TAT126400X05
500/5A 4 8 TAT126500X05
600/5A 6 12 TAT126600X05
800/5A 8 15 TAT126800X05
1000/5A 12 20 tat1261K0X05
1200/5A 15 30 TAT1261K2X05
1500/5A 20 40 TAT1261K5X05
2000/5A 30 60 tat1262K0X05
2500/5A 40 80 tat1262K5X05
3000/5A 50 80 TAT1263K0X05
4000/5A 60 100 TAT1264K0X05
15-673
Stock Status:Normally stocked /Not normally stocked
15
Discount code c4
15.10. Split-Core Current Transformers
taa031 Series - order codes
taa081 Series - order codes
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1 cL 3
21 x 32mm 100/5A 1.5 taa031100X05
150/5A 1.5 TAA031150X05
250/5A 1 2.5 4 taa031200X05
400/5A 2.5 3.75 6 taa031400X05
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1
50 x 81mm 250/5A 1 2 TAA081250X05
400/5A 1.5 3 taa081400X05
500/5A 2.5 5 TAA081500X05
600/5A 2.5 5 taa081600X05
800/5A 4 5 taa081800X05
1000/5A 5 10 taa0811K0X05
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.10. Split-Core Current Transformers Stock Status:
Normally stocked /Not normally stocked
15
Discount code c4
taa121 Series - order codes
taa161 Series - order codes
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1
80.5 x 121mm 800/5A 3 6 TAA121800X05
1000/5A 4 8 taa1211K0X05
1200/5A 5 10 TAA1211K2X05
1500/5A 7.5 10 taa1211K5X05
Busbar ratio accuracy class (Burdens Va) code
cL 0.5 cL 1
80.5 x 161mm 1000/5A 6 10 TAA1611K0X05
1500/5A 8 10 TAA1611K5X05
2000/5A 10 15 TAA1612K0X05
2500/5A 15 20 TAA1612K5X05
3000/5A 20 25 TAA1613K0X05
4000/5A 20 25 TAA1614K0X05
5000/5A 20 25 TAA1615K0X05
15-675
Stock Status:Normally stocked /Not normally stocked
15
Discount code c4Discount code L13
15.11. Current Transducers
Mac Series – Solid core - order codes
H92x Series – Split core - order codes
Hx21 Series – Split core - order codes
output Selectable input range aux. Supply cable Busbar code
4 to 20mA 5A, 6A, 7.5A, 10A, 15A, 20A, 25A, 30A
10-32VDC ø 21mm 20 x 10mm Mac022XXXg42
50A, 60A, 75A,100A, 125A, 150A, 200A, 250A, 300A
10-32VDC ø 23mm 32 x 10mm Mac032XXXg42
100A, 120A, 150A, 200A, 250A, 300A, 400A, 500A, 600A
10-32VDC ø 32mm 40 x 10mm Mac040XXXg42
output Selectable input range aux. Supply cable code
4 to 20mA 0 – 30/60/120A N/A ø 21mm H921
0 to 10VDC 0 – 20/100/150A N/A ø 21mm H923
output Selectable input range aux. Supply cable code
4 to 20mA 0 – 300A 12 -30VDC ø 30mm H221
0 – 800A 12 – 30VDC ø 58mm H321
0 – 2400A 12 – 30VDC ø 60mm H421
Mac022XXXg42 Mac032XXXg42 Mac040XXXg42
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEntStock Status:normally stocked /Not normally stocked
15
15.12. Current Switches
Xac Series adjustable trip Point – Solid core - order codes
Hx08 Series adjustable trip Point – Split core - order codes
Hx00 Series Fixed trip Point go/no go – Split core - order codes
output range alarm range cable Busbar code
NO Relay Contact (100mA, 250V AC1)
50A 5 - 60A ø 23mm 32 x 10mm XAC032050XMO
100A 10 – 120A ø 23mm 32 x 10mm XAC032100XMO
150A 15 – 180A ø 23mm 32 x 10mm XAC032150XMO
250A 25 – 300A ø 23mm 32 x 10mm XAC032250XMO
400A 40 - 480A ø 23mm 32 x 10mm XAC032400XMO
600A 60 – 720A ø 23mm 32 x 10mm XAC032600XMO
400A 40 - 480A ø 32mm 40 x 10mm XAC040400XMO
600A 60 – 720A ø 32mm 40 x 10mm XAC040600XMO
1000A 100 – 1200A ø 32mm 40 x 10mm XAC0401K0XMO
* Note – It is possible to set the max. Alarm threshold from 10% to 120% of the current range. (Example: Range = 100A therefore max. alarm threshold if from 10A to 120A)
output range alarm range cable code
N.O. 1.0A@30VAC/DC
175A 0.5 – 175A ø 13mm H608
135A 2.5 – 135A ø 21mm H908
output range alarm range cable code
N.O. 1.0A@30VAC/DC
200A 0.15 – 200A ø 13mm H600
1.5 – 200A ø 21mm H900
Discount code c4Discount code L13
H600, H608
Xac032
H900, H908
Xac040
15-677
15
15.13. Software15.13.1. Power Analysis
PAS is SATEC’s comprehensive analysis and engineering software designed to program and monitor all SATEC devices. It includes a variety of additional tools to assist in system setup, such as the communication debugging module. PAS is bundled with all SATEC instruments at no extra charge.
Power analysis Software
Features:
Automatic power quality reports for EN50160, IEEE1159 and GOST 13109Automatic polling of devicesSimple off-line instrument setupDirect data access for status monitoring or analysis
Wide range of communication platforms:• RS standard serial lines• TCP/IP• USB
Sophisticated analysis:• Data logs—historical or current• Trends—individual or 3 phases together• Trend over time data log or waveform• Trend based on user-selected parameters or limits• Harmonic spectrum• Harmonics power direction• EN50160 comparison tables for HV and LV applications• G5/4 comparison tables for HV and LV applications• Vector analysis/phasor diagram• Automatic power quality and fault categorization• Synchronized waveforms from multiple devices in a single plot• ITI (CBEMA) curve• Automatic sort and filter capabilities• Uploading TOU settings• Uploading with variable setpoints• Alarms with variable setpoints• Delta measurement
Easy export to spreadsheet, Word, Excel or databaseExtensive graphic and report capabilities for waveforms and harmonicsExport COMTRADE (IEEE standard common format for transient data exchange)
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
15. EnErgy ManagEMEnt15.13. Software
15
15.13.2. ExpertPower
eXpertpowerTM software solution provides comprehensive energy management, billing, demand response, power quality analysis and generator control. eXpertpowerTM is available either as an on-line service (SaaS—Software as a Service) or as a stand-alone package.
SATEC’s solution includes our wide range of analyzers and the eXpertpowerTM software, providing the information and analytics to improve the efficiency, reliability, security and profitability of our customers’ energy system.
applications
real time & Historic data display• Electrical data• Max demands• Data logs
Energy consumption• Import, Export and Total• TOU (Time of Use)
Power Quality analysis• Events• Compliance reports• Waveforms analysis
ExpertPower
DashboardThe Dashboard page enables a customized view for each user. It offers many optional modules, such as last reading, history, events, graphical maps and more.
Summary toUThe summary TOU (Time of Use) page displays energy and cost values for each measured point for a selected site. The pie chart presents a clear view for comparing each measured point behavior.
Last readingThe Last Reading page shows the lastbasic measurement readings according to the selected device type. The data can be printed or exported to datasheet. The user can also drill down to gain the detailed historic data by selecting the appropriate History link.
Energy BillingThe energy billing page details all the data required to generate a bill for a selected period. The bill is constructed based on tariff definitions. Energy and cost indicator graphs are also available.
History graphThe page shows historic data in graphic and tabular forms. There is an option to change the shown parameter type as well as the presented date range, through the toolbar options. Also, there is full support for datasheet data export and printing of all the selected data.
Power QualityThe Power Quality analysis module provides comprehensive tools for troubleshooting events. It includes statistical and detailed event information, including waveforms, phasors and tables, for easy generation of compliance reports according to EN50160, IEEE1159, GOST 13109 and more.
Selected Screenshots
eXpertpowerTM’s web-enabled concept makes controlling comprehensive electrical data as easy as ABC. It reduces the total cost of ownership (TCO) by eliminating the need for training, special hardware or software—without compromising the power of the server side. With installations of over 10,000 managed devices at one site, it is the most powerful energy management solution in the market. Its scalability allows you to start with small installations and to expand as your business grows.
Sub-metering Billing• Dynamic tariff definitions• Accurate cost calculations• Invoices generations
Demand response• Calculate facility usage and energy
distribution• Automatic generators operation
advanced reporting• Scheduled reports• Multidimensional comparisons• Customized content and look per report• Print, export, save and send reports
15-679
15
15.14. On Site Testing Services
control Logic + SatEc provide a comprehensive range of value added on-site serives that support and enhance our energy management solution for your site.
Below is a list of services we can supply:
• NABERS Assessment• Energy Audits• Power Quality Audits• Meter Verification
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16.1.1. MicroSection Guide Overview
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16. Lightning & Surge Protection
Section 16
16-681
Lightning & Surge Protection
16. Lightning & Surge Protection 16-680Section guide overview 16-682
A Systematic Approach 16-682Key Product Features 16-683Product Specification Reference Terms 16-684
16.1. Power Protection 16-685Selecting Power Protection 16-68516.1.1. Surge Diverters 16-68616.1.2. High Voltage Surge Diverters 16-69116.1.3. Spark Gap Arresters 16-69216.1.4. Hybrid Spark Gap Arresters 16-69316.1.5. Series Surge Protectors 16-69416.1.6. Surge Filters 16-696
16.2. Process control Protection 16-704Selecting Process Control Protection 16-70416.2.1. Twisted Pair Signal Protection 16-70616.2.2. High Current Signal Line Protectors 16-70916.2.3. Multiline Signal Protection 16-71016.2.4. Serial Port Protection 16-71116.2.5. Load Cell Protection 16-712
16.3. LAn & cctV Protection 16-71316.3.1. Coaxial CCTV Protection 16-71316.3.2. CCTV Protection 16-71516.3.3. LAN Protection 16-716
16.4. coaxial Protection 16-717Selecting Coaxial Protection 16-71716.4.1. RF Equipment Protection 16-718
16.5. telephone Protection 16-72416.5.1. KP KRONE-LSA® 16-72416.5.2. RJ Modular Plug Protection 16-725
16.6. intrinsically Safe 16-72616.6.1. IS Signal Line Protectors 16-72616.6.2. IS High Speed Signal Line Protectors 16-72716.6.3. IS Series Surge Protectors 16-72816.6.4. IS Instrument Protectors 16-72916.6.5. IS Load Cell Protectors 16-730
16.7. Special Products 16-73116.7.1. Surge Indicator Panel 16-73116.7.2. EC Earth Clamp 16-73216.7.3. Cable Bonding Kit 16-73416.7.4. Transient Surge Counter 16-735
16.8. overview 16-736Standards & Safety 16-736Risk Assessment 16-736Surge Ratings 16-737Installation 16-738
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection
For your information:NSW & VIC only
16
Section Guide OverviewA Systematic Approach
Lightning strikes are an unpredictable natural phenomenon. However the way equipment can be protected from lightning strikes is predictable. The ‘Novaris Systematic Approach’ is a step-by-step solution to lightning and surge protection that can be applied to any application.
Define Boundaries Boundaries divide areas of different potential.
Protect Structure Novaris supports conventional lightning protection methods.
Install Bonded Earthing System A single bonded earthing system within each boundary is essential.
Protect Power Lines Protect all power lines crossing protection boundaries.
Protect Signal/Data Lines Protect all signal/data lines crossing protection boundaries.
Control Logic offers:
Investigation and Analysis - Novaris offers a complete package from analysis of your existing lightning and surge protection system to providing complete recommendations based on site surveys and technical analysis.
Structural Lightning Protection and Earthing Systems- Design and advice on lightning protection systems for all structures in accordance with recognised world standards.- supply of structural lightning protection and earthing components.
A Comprehensive range of Surge Protection Products to suit any application - Ranging from main switchboard and distribution board surge protection, PLC and control system protection, to RF coaxial protection.
Custom Product Design - The Novaris innovative R&D team can engineer a surge protection solution for even the most demanding of applications.
Project Management & Installation - Novaris actively seeks consultancy, project management and installation work. Our experience extends from Australia to the Pacific, Asia, Africa and the Middle East.
12345
16-683
Section Guide OverviewFor your Information:NSW & VIC only
16
Key Product Features
All ModeProtection
MultistagetransientProtection
redundantSegments
ThermalSensing
88%PercentageActive Display
LeD StatusDisplay
SiP and External Alarms
Din 43880Compliant
Safe Metalenclosure
IECiecCompliant
Compliant with the relevant IEC lightning and surge protection standards, in particular IEC 62305 and IEC 61643.
Novaris models featuring all mode protection provide protection for all combinations of lines (L-N, L-E, N-E) ensuring the maximum level of protection is achieved at all times. They have been designed for installation in any wiring system worldwide.
Models featuring multistage transient protection deliver greater levels of protection through a staged approach. The primary stage absorbs the majority of the surge energy. The remaining stages provide accurate clamping and a degree of redundancy.
Models featuring redundant segments have a parallel redundant arrangement of high energy metal oxide varistors (MOVs), thus promoting long life and exceptional surge handling capacity.
Sustained overvoltages can cause components to overheat and degrade. Thermal sensing warns of this condition without disconnecting the protection.
A digital display confirms the device rating upon switch on, then displays percentage active. The display indicates segment status and thermal overload.
LED indicators are provided to indicate operating status.
The Novaris Surge Indicator Panel (SIP) allows remote monitoring of any Novaris product featuring external alarms. Models featuring external alarms have voltage free changeover contacts (SPDT) for remote status indication.
Protection devices housed in DIN 43880 compliant enclosures allow for convenient installation on DIN rail fittings commonly used in switchboards worldwide.
Novaris surge protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge ProtectionSection Guide Overview
For your Information:NSW & VIC only
16
Product Specification Reference Terms
Ph Phase
iimp Defined by three parameters, a current peak value, a charge and a specific energy. Generally relates the IEC definition of a direct lightning strike modelled by a 10/350µs waveshape. This is used for the classification of SPDs for test class I in accordance with IEC61643-1.
Q Charge contained in a test waveform. Expressed in coulombs (As).
W/R Specific Energy relating to a test waveform. Expressed in kJ/µs.
imax Defined as the peak value of a current through the SPD having an 8/20µs waveshape. This is used for the classification of SPDs for test class II in accordance with IEC61643-1. This is generally recognized for MOV based SPDs as the single shot impulse rating.
in Defined as the peak value of a current through the SPD having an 8/20µs waveshape. This is used for the classification of SPDs for test class II in accordance with IEC61643-1. This is known as the nominal discharge current and is generally recognized for MOV based SPDs as the rating of the SPD for 15 such impulses.
iL The maximum continuous RMS or DC current that can be supplied to a load connected to a two port or series connected SPD.
if The current supplied by the electrical power system which flows through an SPD after a discharge current impulse. This is called the follow-on current and is particularly applicable to voltage switching type SPDs such as spark gaps and gas discharge tubes.
ifi Follow-on current interrupting rating. This is the maximum AC RMS current that a voltage switching SPD such as a spark gap can interrupt.
u0 The RMS line to neutral voltage of the power system.
uc The maximum RMS or DC voltage, which may be continuously applied to an SPD.
up The let through voltage of an SPD defined for a specified test waveform.
tA Response time of an SPD to a defined test waveform.
Du Voltage drop of a two port SPD at rated current expressed as a percentage of U0.
fc The maximum usable frequency.
16-685
For your Information:NSW & VIC only
16
16.1. Power ProtectionSelecting Power Protection
1. Provide adequate protection for all equipment.2. Achieve a long working life.3. Optimise the cost and size of the surge protection devices (SPDs).
There are two common configurations of SPDs: One port SPDs are parallel or shunt connected across the line. These include the Novaris SD, SG and HSG products.
Two port SPDs are connected in series with the line. These include the Novaris SSP, SF and PP products.There are two classes of SPD components:
Voltage limiting SPDs include metal oxide varistors and suppressor diodes. These have a high impedance when no surge is present but can reduce impedance continuously with increased surge current and voltage. These are also called “clamping devices”. Novaris SD, SSP, SF and PP products are voltage clamping SPDs.
Voltage switching SPDs include spark gaps, gas discharge tubes, thyristors and triacs. These have a high impedance when no surge is present but can have a sudden change to a low impedance in response to a voltage surge. These are also called “crowbar devices”. The Novaris SG products are voltage switching SPDs.
Sometimes a combination of these components may be used. The Novaris HSG is an example of a combination SPD.
1. Surge Diverters, SDAll Novaris surge diverters with initial product code SD employ metal oxide varistor (MOV) voltage limiting components. These can be used for main switchboard primary protection, distribution board and final circuit protection. As voltage limiting components there is no follow on current, and with suitable fusing these are easy to install and operate.
SD products are suitable for all applications except where extreme voltage fluctuations may be experienced. Excessive overvoltage can damage MOV based SPDs although all Novaris surge diverters are housed in metal enclosures and meet the fail-safe requirements of UL1449 - specifically package rupture and the effects of excessive heating.
2. Spark Gaps, SGSpark gaps have high surge ratings and are suitable for point of entry protection in installations with highly exposed overhead LV power lines with no local transformer in high lightning areas. As voltage switching SPDs, spark gaps have a crowbar effect and effectively place a short circuit across the line once fired. Thus high levels of AC follow on current will flow. Unless properly configured to be compatible with the AC fault rating of the supply and suitably fused, spark gaps can cause nuisance tripping of supply circuit breakers and extreme voltage disturbances whilst the follow on current flows.
3. Hybrid Spark Gaps, HSGHybrid spark gaps combine the best qualities of voltage switching and voltage limiting components. Novaris HSG hybrid spark gaps are suitable for all high exposure installations and meet the recommendations of IEC61643-12 in relation to surge ratings with Imax of 250kA (8/20µs) or Iimp of 25kA (10/350µs)*. The spark gap in the HSG is a high energy gas discharge tube with a clearly defined impulse firing voltage, its let through voltage closely approaches that of an MOV based surge diverter.
4. Series Surge Protector, SSPAll shunt connected SPDs are compromised in performance by the presence of their interconnecting leads. Typically voltage drops of 500V per meter of connecting lead can be expected. Such lead lengths are often unavoidable in physically large main switchboards. Nevertheless one port SPDs provide effective protection for the main switchboard.
For circuits that are more sensitive the SSP provides a means of eliminating the shunt connected leads and places the SPD directly across the line. Such applications might include UPS inputs, rectifiers, VSDs and motors.
5. Surge Filters, SF The surge filter is a true two port SPD offering an extremely low let through voltage capable of protecting the most sensitive of electronic circuits. The Novaris range of surge filters is extensive: from 2A DIN rail mount units designed to protect sensitive PLCs and process equipment; plug in units for final circuit outlets; to 2000A per phase filters designed to protect major data centres. Surge ratings up to 250kA (8/20µs) are available making surge filters suitable for providing primary and secondary protection in one package as may be required at a cellular basestations, process plant control rooms or data centres. As surge filters are series connected they must have a current rating IL equal to or greater than the protected circuit.
Power line surge protection must
Options for Surge Protection Devices
Selection of Surge Protection Devices
SPD
SPD
U
U
U
U
Z
U
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.1. Surge Diverters
SD Surge Diverters
Novaris MULTIMOV MSB surge diverters offer unsurpassed safety, quality and reliability in protection for your electrical system. MULTIMOV surge diverters are an ideal point-of-entry protector for all industrial, commercial and communications applications.
Electrical Specifications
Connection Type Shunt
Modes of protection L-N
Phases 1 3
Nominal voltage U0 230V / 50Hz (110V / 60Hz by request only)
Maximum continuous voltage Uc 275V / 50Hz (130V / 60Hz by request only)
Maximum discharge current (8/20µs) Imax 100kA 150kA 200kA 250kA 100kA 150kA 200kA 250kA
Voltage protection level @ 3kA (8/20µs)
Up <800V
Response time tA <5ns
Earth leakage current <5µA
Display 7-segment LED, percentage active
Alarms Segment / thermal failure, clean SPDT contact
Alarm isolation to active circuitry 4kV
Recommended backup fuse (HRC) / circuit breaker
63A 80A 100A 125A 63A 80A 100A 125A
Dimensions
Width 60mm 260mm
Height 200mm 310mm
Depth 70mm 78mm
SD1-
100-
275
SD1-
150-
275
SD1-
200-
275
SD1-
250-
275
SD3-
100-
275
SD3-
150-
275
SD3-
200-
275
SD3-
250-
275
SD 1 - 100 - 275 - [M]
Product Series Options Phase Uc Imax
IEC
order codes
Description code
Surge Diverter, MULTIMOV, 1Ph, 100kA, Redundant with Alarm Contact SD1-100-275
Surge Diverter, MULTIMOV, 1Ph, 150kA, Redundant with Alarm Contact SD1-150-275
Surge Diverter, MULTIMOV, 1Ph, 200kA, Redundant with Alarm Contact SD1-200-275
Surge Diverter, MULTIMOV, 1Ph, 250kA, Redundant with Alarm Contact SD1-250-275
Surge Diverter, MULTIMOV, 3Ph, 100kA, Redundant with Alarm Contact SD3-100-275
Surge Diverter, MULTIMOV, 3Ph, 150kA, Redundant with Alarm Contact SD3-150-275
Surge Diverter, MULTIMOV, 3Ph, 200kA, Redundant with Alarm Contact SD3-200-275
Surge Diverter, MULTIMOV, 3Ph, 250kA, Redundant with Alarm Contact SD3-250-275
options
N-E Protection for SD3-XXX N
Metal Enclosure for SD3-XXX M
Polycarbonate Enclosure for SD3-XXX P
Extended Voltage Option for SDN3 Only (95-415V / 50Hz) X
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 category C
IEEE C62.41 category C
BS 6651 category C
CP 33 category C
IEC 1000-4-5
UL1449 third edition
A-tick
16-687
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.1. Surge Diverters
SDN All Mode Surge Diverters
Novaris SDN Surge Diverters are the ideal choice for all mode protection in major distribution switchboards. Being all mode the SDN is particularly suitable for switchboards in non MEN installations.
SDN 1 - 50 - 275 - P
Product Series Options Phase Uc Imax
order codes
Description code
Surge Diverter, A-N, A-E, N-E 50kA with Alarm Contact SDN1-50-275
Surge Diverter, A-N, A-E, N-E 100kA with Alarm Contact SDn1-100-275
Surge Diverter, 3Ph-N, N-E 50kA with Alarm Contact SDn3-50-275
Surge Diverter, 3Ph-N, N-E 100kA with Alarm Contact SDn3-100-275
Surge Diverter, 3Ph-N, N-E 150kA with Alarm Contact SDn3-150-275
Surge Diverter, 3Ph-N, N-E 200kA with Alarm Contact SDn3-200-275
options
Metal Enclosure for SDN M
Polycarbonate Enclosure for SDN P
Extended Voltage Option for SDN3 Only (95-415V / 50Hz) X
Electrical Specifications
Connection type Shunt
Modes of protection All mode (L-N, L-PE, N-PE)
Phases 1 3
Nominal voltage U0 230V / 50Hz (110V / 60Hz by request only)
Maximum continuous voltage Uc 275V / 50Hz (130V / 60Hz by request only)
Maximum discharge current (8/20µs) Imax 50kA 100kA 50kA 100kA 150kA 200kA
Voltage protection level @ 3kA (8/20µs) Up <800V
Response time tA <5ns
Earth leakage current <500µA
Display LED, status
Alarms Segment / thermal failure, clean SPDT contact
Alarm isolation 4kV
Backup fuse (HRC) 32A 63A 32A 63A 80A 100A
Dimensions
Width 60mm 80mm 120mm
Height 200mm
Depth 70mm
IECSD
N1-
50-2
75
SDN
1-10
0-27
5
SDN
3-50
-275
SDN
3-10
0-27
5
SDN
3-15
0-27
5
SDN
3-20
0-27
5
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 categories B, C
IEEE C62.41 categories B, C
BS 6651 categories B, C
CP 33 categories B, C
IEC 1000-4-5
UL1449 third edition
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
SDD DINsafe Surge Diverters
Novaris SDD DINsafe Surge Diverters offer powerful performance at domestic MSB and industrial DBs. The SDD diverters are housed in DIN compliant, fail-safe metal enclosures and are fully compliant to AS/NZS1768-2007 and to AS/NZS3000 wiring rules.
order codes
Description code
Surge Diverter, 1Ph, 50kA, DINSafe, 3 Mode SDD1-50-275
Surge Diverter, 1Ph, 50kA, DINSafe, 3 Mode with Alarm Contact SDD1-50-275-A
Surge Diverter, 1Ph, 100kA, DINSafe, 3 Mode SDD1-100-275
Surge Diverter, 1Ph, 100kA, DINSafe, 3 Mode with Alarm Contact SDD1-100-275-A
Surge Diverter, 3Ph, 50kA, DINSafe, 3 Mode SDD3-50-275
Surge Diverter, 3Ph, 50kA, DINSafe, 3 Mode with Alarm Contact SDD3-50-275-A
Surge Diverter, 3Ph, 100kA, DINSafe, 3 Mode SDD3-100-275
Surge Diverter, 3Ph, 100kA, DINSafe, 3 Mode with Alarm Contact SDD3-100-275-A
IEC Electrical Specifications
Connection type Shunt
Modes of protection All mode (L-N, L-PE, N-PE)
Phases 1 3
Nominal voltage U0 230V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum discharge current (8/20µs) Imax 50kA 100kA 50kA 100kA
Nominal Discharge current (8/20µs) In 20kA 40kA 20kA 40kA
Maximum switchboard fault rating ISCCR 25kA 50kA 25kA 50kA
Voltage protection level @ 3kA (8/20µs)
Up <800V
Response time tA <5ns
Earth leakage current <10µA
Display LED status per phase
Alarms (optional) Power fail safe, thermal overload, SPDT voltage free contact
Alarm isolation 4kV
Maximum fuse (HRC) 125A 250A 125A 250A
Dimensions
Width 18mm 36mm 54mm 72mm
Height 95mm
Depth 70mm
SDD1
-50-
275
SDD1
-50-
275-
A
SDD1
-100
-275
SDD1
-100
-275
-A
SDD3
-50-
275
SDD3
-50-
275-
A
SDD3
-100
-275
SDD3
-100
-275
-A
SDD 1 - 50 - 275 - [*]Product Series Options Phase Uc Imax
Standards Compliance
IEC 61643-1 class II
AS/NZS 1768 categories B, C
IEEE C62.41 categories B, C
UL1449 third edition
16.1.1. Surge Diverters
16-689
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
SDD2 DINsafe Surge Diverters
Novaris SDD2 Surge Diverters offer an ideal solution for DC and two phase systems. The SDD2 diverters are housed in a DIN compliant, fail-safe metal enclosure.
order codes
Description code
Surge Diverter,10kA, 2 Pole 12VDC Nominal Voltage SDD2-10-18-DC
Surge Diverter,10kA, 2 Pole 24VDC Nominal Voltage SDD2-10-45-DC
Surge Diverter,10kA, 2 Pole 24VAC Nominal Voltage SDD2-10-30-AC
Surge Diverter,32kA, 2 Pole 48VDC Nominal Voltage SDD2-32-65-DC
Surge Diverter,50kA, 2 Pole 110VAC Nominal Voltage SDD2-50-130-AC
Surge Diverter,50kA, 2 Pole 110VDC Nominal Voltage SDD2-50-150-DC
Surge Diverter,100kA, 2 Pole 110VDC Nominal Voltage SDD2-100-150-DC
IEC Electrical Specifications
Connection Type Shunt
Modes of protection Common and transverse modes or L1-PE and L2-PE
Phases / poles 2
AC / DC DC AC DC AC DC
Nominal voltage UN 12V 24V 48V 110V
Maximum continuous voltage Uc 18V 45V 30V 65V 130V 150V
Maximum discharge current (8/20µs) Imax 10kA 32kA 50kA 100kA
Voltage protection level @ 3kA (8/20µs) Up <80V <150V <190V <400V
Response time tA <5ns
Earth leakage current <10µA
Display LED status
Dimensions
Width 72mm
Height 95mm
Depth 80mm
SDD2
-10-
18-D
C
SDD2
-10-
45-D
C
SDD2
-10-
30-A
C
SDD2
-32-
65-D
C
SDD2
-50-
130-
AC
SDD2
-50-
150-
DC
SDD2
-100
-150
-DC
Product Series AC / DCImax Uc
SDD2 - 10 - 18 - DC
Standards Compliance
IEC 61643-1 class II, III
AS/NZS 1768 categories A, B, C
IEEE C62.41 categories A, B, C
BS 6651 categories A, B, C
CP 33 categories A, B, C
IEC 1000-4-5
UL1449 third edition
16.1.1. Surge Diverters
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
SDPV Surge Diverters - Photovoltaic
Novaris SDPV surge diverters provide the highest level of protection for photovotaic equipment with voltages up to 1000V. Their compact design makes them an ideal choice for space restricted applications.
order codes
Description code
Surge Diverter,40kA, 2 pole 400VDC nominal SDPV-40-400
Surge Diverter,40kA, 2 pole 400VDC nominal with alarm output SDPV-40-400-A
Surge Diverter,40kA, 2 pole 600VDC nominal SDPV-40-600
Surge Diverter,40kA, 2 pole 600VDC nominal with alarm output SDPV-40-600-A
Surge Diverter,40kA, 2 pole 800VDC nominal SDPV-40-800
Surge Diverter,40kA, 2 pole 800VDC nominal with alarm output SDPV-40-800-A
Surge Diverter,40kA, 2 pole 1000VDC nominal SDPV-40-1000
Surge Diverter,40kA, 2 pole 1000VDC nominal with alarm output SDPV-40-1000-A
IEC
Product Series OptionsImax Uc
SDPV - 40 - 1000 - [*]
Standards Compliance
IEC 61643-31
AS/NZS 1768 categories A, B
Electrical Specifications
Connection type Series
Modes of protection All mode ((+)-(-), (+)-PE, (-)-PE)
Phases 2
Maximum continuous voltage Ucpv 400V 600V 800V 1000V
Maximum discharge current (8/20μs) Imax 40kA
Nominal Discharge Current (8/20μs) In 20kA
Voltage protection level @ 3kA (8/20μs) UP <1600V <2500V <3600V <4000V
Response time tA Instantaneous
Earth leakage current <200μA
Display LED status
Alarms (optional) Thermal failure
Alarm isolation to active circuitry 4kV
Dimensions
Width 90mm
Height 95mm
Depth 70mm
SDPV
-40-
400
SDPV
-40-
400-
A
SDPV
-40-
600
SDPV
-40-
600-
A
SDPV
-40-
800
SDPV
-40-
800-
A
SDPV
-40-
1000
SDPV
-40-
1000
-A
16.1.1. Surge Diverters
16-691
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
SDH High Voltage Surge Diverters
Novaris SDH High Voltage Surge Diverters have been engineered for system voltages above 600VRMS. Typical applications include aviation runway lighting, mining and railway industries.
order codes
Description code
Surge Diverter, 100kA, 550V, Fuse Base Mount SDH-100-550
Surge Diverter, 200kA, 1000V, Fuse Base Mount SDH-200-1000
Surge Diverter, 100kA, 1500V, Fuse Base Mount SDH-100-1500
Surge Diverter, 100kA, 2000V, Fuse Base Mount SDH-100-2000
IEC
Product Series Imax Uc
SDH - 100 - 2000
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 category C
IEEE C62.41 category C
BS 6651 category C
CP 33 category C
Electrical Specifications
Connection type Shunt
Modes of protection L-PE
Phases 1
Maximum continuous voltage U0 550V 1000V 1500V 2000V
Maximum discharge current (8/20µs) Imax 100kA 200kA 100kA
Voltage protection level @ 3kA (8/20µs) Up 1.6kV 2.6kV 3.8kV 4.8kV
Response time tA <5ns
Dimensions
Width 164mm 193mm 164mm 193mm
Height 56mm
Depth 162mm
SDH
-100
-550
SDH
-200
-100
0
SDH
-100
-150
0
SDH
-100
-200
0
16.1.2. High Voltage Surge Diverters
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.3. Spark Gap Arresters
Sg Spark gap Arresters
Novaris SG Spark Gap Arresters have high surge ratings suitable for point of entry protection in installations with highly exposed overhead LV power lines with no local transformer. These are triggered spark gaps resulting in relatively low let through voltages sufficient to protect switchgear in main switchboards.
SG 1 - 50 - 275 - [M]Product Series Options Phase Uc Iimp
IEC Electrical Specifications
Connection type Shunt
Modes of protection L-N L-N N-PE
Phases 1 3 -
Nominal voltage U0 230V / 50Hz
Maximum continuous voltage Uc 255V / 50Hz 275V / 50Hz 255V / 50Hz 275V / 50Hz
Interrupting follow current @ Uc Ifi 25kARMS 60kARMS 25kARMS 60kARMS 100ARMS
Lightning impulse voltage sparkover (1.2/50µs) Up <1.3kV <2.5kV <1.3kV <2.5kV <1.5kV
Maximum impulse current (10/350µs) Iimp 50kA 110kA 50kA 110kA 100kA
Charge Q 25As 55As 25As 55As 50As
Specific energy W/R 600kJ/W 3000kJ/W 600kJ/W 3000kJ/W 2500kJ/W
Response time tA <100ns
Backup fuse (HRC) 315A 500A 315A 500A -
Dimensions
Width 36mm 67mm 106mm 201mm 36mm
Height 90mm 150mm 90mm 150mm 90mm
Depth 67mm 94mm 67mm 94mm 67mm
SG1-
50-2
55
SG1-
110-
275
SG3-
50-2
55
SG3-
110-
275
SGN
-100
-275
order codes
Description code
Spark Gap Arrestor L-N, 50kA 10/350us Class 1, Uc 255VRMS SG1-50-255
Spark Gap Arrestor L-N, 110kA 10/350us Class 1, Uc 255VRMS SG1-110-275
Spark Gap Arrestor Combination 3Ph (For MEN Systems) SG3-50-255
Spark Gap Arrestor Combination 3Ph (For MEN Systems) SG3-110-275
Spark Gap Arrestor N-E, 100kA 10/350us Class 1, Uc 275VRMS SGN-100-275
options
Metal Enclosure M
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 category C
IEEE C62.41 category C
BS 6651 category C
CP 33 category C
IEC 1000-4-5
16-693
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.4. Hybrid Spark Gap Arresters
hSg hybrid Spark gap Arresters
Novaris HSG Hybrid Spark Gap Arresters combine the best qualities of voltage switching and voltage limiting components. Novaris HSG hybrid spark gaps suit all high exposure installations. There is no follow on current. The HSG is ideal for applications where mains voltages fluctuations are significant.
Product Series Options Phase Uc Iimp
HSG 1 - 25 - 275 - [M]
IEC Electrical Specifications
Connection type Shunt
Modes of protection L-N
Phases 1 3
Nominal voltage U0 230V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Interrupting follow current @ Uc Ifi -
Lightning impulse voltage sparkover (1.2/50µs) Up <1.1kV
Maximum impulse current (10/350µs) Iimp 25kA
Charge Q 12.5As
Specific energy W/R 625kJ/W
Response time tA <100ns
Display LED status
Alarms Clean SPDT contact
Alarm isolation to active circuitry 4kV
Backup fuse (HRC) 63A
Dimensions
Width 60mm 240mm
Height 200mm 260mm
Depth 70mm 78mm
HSG
1-25
-275
HSG
3-25
-275
order codes
Description code
Hybrid Diverter L-N, 25kA 10/350us 275VRMS HSG1-25-275
Hybrid Diverter L-N 3Ph, 25kA 10/350us 275VRMS HSG3-25-275
options
Neutral-Earth Protection (For Non MEN Systems) N
Metal Enclosure M
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 category C
IEEE C62.41 category C
BS 6651 category C
CP 33 category C
IEC 1000-4-5
UL1449 third edition
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.5. Series Surge Protectors
SSP Surge Protectors - Single Phase
Novaris SSP protectors are suitable for installation in circuits up to 63A. The SSP range has been engineered to provide excellent performance and economical protection. Their compact design makes them an ideal choice for space restricted applications.
order codes
Description code
Series Surge Protector, 1Ph, 6A, 6.5kA, DINSafe, 275VRMS SSP1-6-6.5-275
Series Surge Protector, 1Ph, 10A, 6.5kA, DINSafe, 275VRMS SSP1-10-6.5-275
Series Surge Protector, 1Ph, 20A, 50kA, DINSafe, 275VRMS SSP1-20-50-275
Series Surge Protector, 1Ph, 20A, 100kA, DINSafe, 275VRMS SSP1-20-100-275
Series Surge Protector, 1Ph, 32A, 50kA, DINSafe, 275VRMS SSP1-32-50-275
Series Surge Protector, 1Ph, 32A,100kA, DINSafe, 275VRMS SSP1-32-100-275
Series Surge Protector, 1Ph, 63A, 50kA, DINSafe, 275VRMS SSP1-63-50-275
Series Surge Protector, 1Ph, 63A,100kA, DINSafe, 275VRMS SSP1-63-100-275
Standards Compliance
IEC 61643-1 class II, III
AS/NZS 1768 categories A, B, C
IEEE C62.41 categories A, B, C
BS 6651 categories A, B, C
CP 33 categories A, B, C
IEC 1000-4-5
UL1449 third edition
IEC
Product Series Phase Uc IL Imax
SSP 1 - 63 - 100 - 275
SSP1
-6-6
.5-2
75
SSP1
-10-
6.5-
275
SSP1
-20-
50-2
75
SSP1
-20-
100-
275
SSP1
-32-
50-2
75
SSP1
-32-
100-
275
SSP1
-63-
50-2
75
SSP1
-63-
100-
275
Electrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Phases 1
Nominal voltage U0 240V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum load current IL 6A 10A 20A 32A 63A
Maximum discharge current (8/20µs) Imax 6.5kA 50kA 100kA 50kA 100kA 50kA 100kA
Voltage protection level @ 3kA (8/20µs)
Up <800V
Response time tA <5ns
Earth leakage current <10µA
Display - LED status
Alarms (optional) - Segment / thermal failure, clean SPDT contact
Alarm isolation to active circuitry - 4kV
Backup fuse 6A 10A 20A 32A 63A
Dimensions
Width 18mm 27mm 54mm 72mm
Height 95mm
Depth 80mm
16-695
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
IEC
16.1.5. Series Surge Protectors
SSP Surge Protectors - Three Phase
Novaris SSP protectors are suitable for installation in circuits up to 63A. The SSP range has been engineered to provide excellent performance and economical protection. Their compact design makes them an ideal choice for space restricted applications.
order codes
Description code
Series Surge Protector, 3Ph, 20A, 50kA, DINSafe, 275VRMS, with Alarm Contact SSP3-20-50-275-A
Series Surge Protector, 3Ph, 20A,100KA, DINSafe, 275VRMS, with Alarm Contact SSP3-20-100-275-A
Series Surge Protector, 3Ph, 32A, 50kA, DINSafe, 275VRMS, with Alarm Contact SSP3-32-50-275-A
Series Surge Protector, 3Ph, 32A,100KA, DINSafe, 275VRMS, with Alarm Contact SSP3-32-100-275-A
Series Surge Protector, 3Ph, 63A, 50kA, DINSafe, 275VRMS, with Alarm Contact SSP3-63-50-275-A
Series Surge Protector, 3Ph, 63A,100KA, DINSafe, 275VRMS, with Alarm Contact SSP3-63-100-275-A
Standards Compliance
IEC 61643-1 class II, III
AS/NZS 1768 categories A, B, C
IEEE C62.41 categories A, B, C
BS 6651 categories A, B, C
CP 33 categories A, B, C
IEC 1000-4-5
UL1449 third edition
Product Series Phase Uc IL Imax
SSP 3 - 63 - 100 - 275
SSP3
-20-
50-2
75-A
SSP3
-20-
100-
275-
A
SSP3
-32-
50-2
75-A
SSP3
-32-
100-
275-
A
SSP3
-63-
50-2
75-A
SSP3
-63-
100-
275-
A
Electrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Phases 3
Nominal voltage U0 240V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum load current IL 20A 32A 63A
Maximum discharge current (8/20µs) Imax 50kA 100kA 50kA 100kA 50kA 100kA
Voltage protection level @ 3kA (8/20µs) Up <800V
Response time tA <5ns
Earth leakage current <10µA
Display LED status
Alarms (optional) Segment / thermal failure, clean SPDT contact
Alarm isolation to active circuitry 4kV
Backup fuse 20A 32A 63A
Dimensions
Width 126mm
Height 95mm
Depth 80mm
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.6. Surge Filters
SFH Surge Filters 250 - 800A
Novaris SFH surge filters provide the highest level of protection with the lowest let through voltage. When installed at a main switchboard Novaris surge filters will protect all connected equipment.
order codes
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 category C
IEEE C62.41 category C
BS 6651 category C
CP 33 category C
IEC 1000-4-5
UL1449 third edition
IEC
Product Series OptionsPhase UcIL Imax
SFH 3 - 250 - 100 - 275 - [M]
Electrical Specifications
Connection type SeriesModes of protection All mode (L-N, L-PE, N-PE)Nominal voltage U0 230V / 50HzMaximum continuous voltage Uc 275V / 50Hz Phases 3Discharge current 8/20µs Imax 100kA 200kA 100kA 200kA 100kA 200kA 100kA 200kAMaximum load current IL 250A 400A 630A 800AProtection stages Metal oxide varistor / LC filter / metal oxide varistorVoltage protection @ 3kA (8/20µs) Up <360VResponse time tA InstantaneousEarth leakage current <1µAMaximum voltage drop (% of U0) DU <1%3dB Frequency @ 50W 200Hz 150Hz 80HzDisplays 7-segment LED, percentage activeAlarms Segment / thermal failure, clean SPDT contactAlarm isolation to active circuitry 4kV
Dimensions (in enclosure)Width 710mm 800mmHeight 710mm 1200mmDepth 285mm 400mm
SFH
3-25
0-10
0-27
5
SFH
3-25
0-20
0-27
5
SFH
3-40
0-10
0-27
5
SFH
3-40
0-20
0-27
5
SFH
3-63
0-10
0-27
5
SFH
3-63
0-20
0-27
5
SFH
3-80
0-10
0-27
5
SFH
3-80
0-20
0-27
5Description codeSurge Filter, 250A, 3Ph, 100kA SFH3-250-100-275Surge Filter, 250A, 3Ph, 200kA SFH3-250-200-275optionsHRC Fusing for SFH3-250 HMetal Enclosure for SFH3-250 MDescriptionSurge Filter, 400A, 3Ph, 100kA SFH3-400-100-275Surge Filter, 400A, 3Ph, 200kA SFH3-400-200-275optionsHRC Fusing for SFH3-400 HMetal Enclosure for SFH3-400 MDescriptionSurge Filter, 630A, 3Ph, 100kA SFH3-630-100-275Surge Filter, 630A, 3Ph, 200kA SFH3-630-200-275optionsHRC Fusing for SFH3-630 HMetal Enclosure for SFH3-630 MDescriptionSurge Filter, 800A, 3Ph, 100kA SFH3-800-100-275Surge Filter, 800A, 3Ph, 200kA SFH3-800-200-275optionsHRC Fusing for SFH3-800 HMetal Enclosure for SFH3-800 M
16-697
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.6. Surge Filters
SFH Surge Filters 1200 - 2000A
Novaris SFH surge filters provide the highest level of protection with the lowest let through voltage. When installed at a main switchboard Novaris surge filters will protect all connected equipment.
order codes
Description codeSurge Filter, 1200A, 3Ph, 100kA SFH3-1200-100-275Surge Filter, 1200A, 3Ph, 200kA SFH3-1200-200-275optionsMetal Enclosure for SFH3-1200 MDescriptionSurge Filter, 1600A, 3Ph, 100kA SFH3-1600-100-275Surge Filter, 1600A, 3Ph, 200kA SFH3-1600-200-275optionsMetal Enclosure for SFH3-1600 MDescriptionSurge Filter, 2000A, 3Ph, 100kA SFH3-2000-100-275Surge Filter, 2000A, 3Ph, 200kA SFH3-2000-200-275optionsMetal Enclosure for SFH3-2000 M
Standards Compliance
IEC 61643-1 class I
AS/NZS 1768 category C
IEEE C62.41 category C
BS 6651 category C
CP 33 category C
IEC 1000-4-5
UL1449 third edition
IEC
Product Series OptionsPhase UcIL Imax
SFH 3 - 1200 - 100 - 275 - [M]
Electrical Specifications
Connection type SeriesModes of protection All mode (L-N, L-PE, N-PE)Nominal voltage U0 230V / 50HzMaximum continuous voltage Uc 275V / 50Hz Phases 3Discharge current 8/20µs Imax 100kA 200kA 100kA 200kA 100kA 200kAMaximum load current IL 1200A 1600A 2000AProtection stages Metal oxide varistor / LC filter / metal oxide varistorVoltage protection @ 3kA (8/20µs) Up <360VResponse time tA InstantaneousEarth leakage current <1µAMaximum voltage drop (% of U0) DU <1%3dB Frequency @ 50W 80HzDisplays 7-segment LED, percentage activeAlarms Segment / thermal failure, clean SPDT contactAlarm isolation to active circuitry 4kV
Dimensions (in enclosure)
Width 700mm
Height 1300mm
Depth 340mm
SFH
3-12
00-1
00-2
75
SFH
3-12
00-2
00-2
75
SFH
3-16
00-1
00-2
75
SFH
3-16
00-2
00-2
75
SFH
3-20
00-1
00-2
75
SFH
3-20
00-2
00-2
75
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
SFM Surge Filters 40 -63A
Novaris SFM surge filters provide excellent and effective MSB and DB protection for critical equipment up to 63A per phase.
16.1.6. Surge Filters
IECElectrical SpecificationsConnection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Nominal Voltage U0 230V / 50Hz (110V / 60Hz by request only)
Maximum continuous voltage Uc 275V / 50Hz (130V / 60Hz by request only)
Phases 1 3 1 3
Discharge current 8/20µs Imax 50kA 100kA 50kA 100kA 50kA 100kA 50kA 100kA
Maximum load current IL 40A 63A
Protection stages Metal oxide varistor / LC filter / metal oxide varistor
Voltage protection @ 3kA (8/20µs) Up <360V
Response time tA Instantaneous
Displays LED status
% active LED status
% active LED status
% active LED status
% active
Alarms Segment failure and overcurrent / thermal overload, SPDT contact
Dimensions (in enclosure)Width 310mm 426mm 310mm 426mmHeight 390mm 506mm 390mm 506mmDepth 130mm 200mm 130mm 200mm
SFM
1-40
-50
-275
SFM
1-40
-10
0-27
5
SFM
3-40
-50
-275
SFM
3-40
-10
0-27
5
SFM
1-63
-50
-275
SFM
1-63
-10
0-27
5
SFM
3-63
-50
-275
SFM
3-63
-10
0-27
5
Product Series OptionsPhase UcIL Imax
SFM 1 - 40 - 50 - 275 - [M]
Standards Compliance
IEC 61643-1 class I, II
AS/NZS 1768 categories B, C
IEEE C62.41 categories B, C
BS 6651 categories B, C
CP 33 categories B, C
IEC 1000-4-5
UL1449 third edition
order codes
Description codeSurge Filter, 40A, 1Ph, 50kA SFM1-40-50-275Surge Filter, 40A, 1Ph, 100kA SFM1-40-100-275optionsCircuit Breaker for SFM1-40 CHRC Fusing for SFM1-40 HMetal Enclosure SFM1-40 M DescriptionSurge Filter, 40A, 3Ph, 50kA SFM3-40-50-275Surge Filter, 40A, 3Ph, 100kA SFM3-40-100-275optionsCircuit Breaker for SFM3-40 CHRC Fusing for SFM3-40 HMetal Enclosure SFM3-40 M DescriptionSurge Filter, 63A, 1Ph, 50kA SFM1-63-50-275Surge Filter, 63A, 1Ph, 100kA SFM1-63-100-275optionsCircuit Breaker for SFM1-63 CHRC Fusing for SFM1-63 HMetal Enclosure SFM1-63 M DescriptionSurge Filter, 63A, 3Ph, 50kA SFM3-63-50-275Surge Filter, 63A, 3Ph, 100kA SFM3-63-100-275optionsCircuit Breaker for SFM3-63 CHRC Fusing for SFM3-63 HMetal Enclosure SFM3-63 M
16-699
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
SFM Surge Filters 125A
Novaris SFM surge filters provide excellent and effective MSB and DB protection for critical equipment up to 125A per phase.
16.1.6. Surge Filters
IECElectrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Nominal Voltage U0 230V / 50Hz (110V / 60Hz by request only)
Maximum continuous voltage Uc 275V / 50Hz (130V / 60Hz by request only)
Phases 1 3
Discharge current 8/20µs Imax 50kA 100kA 50kA 100kA
Maximum load current IL 125A
Protection stages Metal oxide varistor / LC filter / metal oxide varistor
Voltage protection @ 3kA (8/20µs) Up <360V
Response time tA Instantaneous
Earth leakage current <1µA
Maximum voltage drop (% of U0) DU <1%
3dB Frequency @ 50W 350Hz
Displays LED status % active LED status % active
Alarms Seg failure and o’current / thermal o’load, SPDT contact
Alarm isolation to active circuitry 4kV
Dimensions (in enclosure)
Width 310mm 426mm
Height 390mm 506mm
Depth 130mm 200mm
SFM
1-12
5-50
-275
SFM
1-12
5-10
0-27
5
SFM
3-12
5-50
-275
SFM
3-12
5-10
0-27
5
Product Series OptionsPhase UcIL Imax
SFM 1 - 125 - 50 - 275 - [M]
Standards Compliance
IEC 61643- class I, II
AS/NZS 1768 categories B, C
IEEE C62.41 categories B, C
BS 6651 categories B, C
CP 33 categories B, C
IEC 1000-4-5
UL1449 third edition
order codes
Description codeSurge Filter, 125A, 1Ph, 50kA SFM1-125-50-275Surge Filter, 125A, 1Ph, 100kA SFM1-125-100-275optionsCircuit Breaker for SFM1-125 CHRC Fusing for SFM1-125 HMetal Enclosure SFM1-125 M DescriptionSurge Filter, 125A, 3Ph, 50kA SFM3-125-50-275Surge Filter, 125A, 3Ph, 100kA SFM3-125-100-275optionsHRC Fusing for SFM3-125 HMetal Enclosure SFM3-125 M
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.6. Surge Filters
SFD Surge Filters - Single Phase
Novaris SFD surge filters provide the highest level of protection for critical and essential equipment up to 32A per phase. Their compact design makes them an ideal choice for space restricted applications.
Product Series Phase Uc IL Imax
SFD 1 - 32 - 100 - 275
Standards Compliance
IEC 61643-1 class II, III
AS/NZS 1768 categories A, B
IEEE C62.41 categories A, B
BS 6651 categories A, B
CP 33 categories A, B
IEC 1000-4-5
UL1449 third edition
Electrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Phases 1
Nominal voltage U0 240V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum load current IL 2A 6A 10A 20A 32A
Maximum discharge current (8/20µs) (L-N)
Imax 6.5kA 50kA 50kA 100kA 500kA 100kA
Nominal Discharge Current (8/20μs) In 3kA 20kA 40kA 20kA 40kA
Voltage protection level @ 3kA (8/20µs) Up <700V <600V
Response time tA Instantaneous
Earth leakage current <500µA <1µA
Maximum voltage drop (% of U0) ΔU <1%
Display LED status
Alarms (optional) - Segment / thermal failure, clean SPDT contact
Alarm isolation to active circuitry - 4kV
Dimensions
Width 27mm (54mm with LED)
54mm 72mm 108mm
Height 116mm (95mm with LED)
95mm
Depth 78mm 70mm
SFD1
-2-6
.5-2
75
SFD1
-6-6
.5-2
75
SFD1
-10-
50-2
75
SFD1
-10-
50-2
75-A
SFD1
-20-
50-2
75
SFD1
-20-
100-
275
SFD1
-32-
50-2
75
SFD1
-32-
100-
275
IEC
order codes
Description code
Filter, 1 Ph, 2A, 6.5kA, 275VRMS SFD1-2-6.5-275
Filter, 1 Ph, 6A, 6.5kA, 275VRMS SFD1-6-6.5-275
Filter, 1 Ph, 10A, 50kA, 275VRMS SFD1-10-50-275
Filter, 1 Ph, 10A, 50kA, 275VRMS with Alarm Contact SFD1-10-50-275-A
Filter, 1 Ph, 20A, 50kA, 275VRMS SFD1-20-50-275
Filter, 1 Ph, 20A, 100kA, 275VRMS with Alarm Contact SFD1-20-100-275-A
Filter, 1 Ph, 32A, 50kA, 275VRMS with Alarm Contact SFD1-32-50-275-A
Filter, 1 Ph, 32A, 100kA, 275VRMS with Alarm Contact SFD1-32-100-275-A
Note: Other options available, please contact customer service.
16-701
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.6. Surge Filters
SFD Surge Filters - Three Phase
Novaris SFD surge filters provide the highest level of protection for critical and essential equipment up to 32A per phase. Their compact design makes them an ideal choice for space restricted applications.
Product Series Phase Uc IL Imax
SFD 3 - 32 - 50 - 275
Standards Compliance
IEC 61643-1 class II, III
AS/NZS 1768 categories A, B, C
IEEE C62.41 categories A, B, C
BS 6651 categories A, B, C
CP 33 categories A, B, C
IEC 1000-4-5
UL1449 third edition
IEC
order codes
Description code
Filter, 3 Ph, 10A, 50kA, 275VRMS with Alarm Contact SFD3-10-50-275-A
Filter, 3 Ph, 20A, 50kA, 275VRMS with Alarm Contact SFD3-20-50-275-A
Note: Other options available, please contact customer service.
Electrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Phases 3
Nominal voltage U0 240V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum load curent IL 10A 20A
Maximum discharge current (8/20µs) (L-N) Imax 50kA
Nominal Discharge Current (8/20μs) In 20kA
Voltage protection level @ 3kA (8/20µs) Up <600V
Response time tA Instantaneous
Earth leakage current <1µA
Maximum voltage drop (% of U0) ΔU <1%
Display LED status
Alarms (optional) Segment / thermal failure, clean SPDT contact
Alarm isolation to active circuitr 4kV
Dimensions
Width 180mm
Height 95mm
Depth 70mm
SFD3
-10-
50-2
75-A
SFD3
-20-
50-2
75-A
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.6. Surge Filters
Plug-in Surge Filters
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.
PP10
A2-5
0
PP10
A4-5
0
PP10
A6-5
0
PP10
A8-5
0
Electrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Nominal voltage U0 230V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum discharge current (8/20µs) Imax 50kA
Maximum load curent IL 10A
Protection stages Metal oxide varistor / LC filter / Metal oxide varistor
Voltage protection level @3kA (8/20µs) Up <600V
Response time tA Instantaneous
Power Consumption (@230V 50Hz) <1W
Attenuation -3dB at 900Hz, -60dB at 100kHz
Earth leakage current <200µA
Maximum voltage drop (% of U0) ΔU <1%
Display LED power and status
Dimensions
Width 155mm 205mm 255mm 305mm
Height 140mm
Depth 60mm
Standards Compliance
IEC 61643-1 class II
AS/NZS 1768 categories B, C
IEEE C62.41 categories B, C
BS 6651 categories B, C
CP 33 categories B, C
IEC 1000-4-5
UL1449 third edition
IEC
Product Series IL Imax Plug type Outlets
PP 10 A 2 - 50
order codes
Description code
Surge Filter Plug In, 10A, Two Outlets, 50kA PP10A2-50
Surge Filter Plug In, 10A, Four Outlets, 50kA PP10A4-50
Surge Filter Plug In, 10A, Six Outlets, 50kA PP10A6-50
Surge Filter Plug In, 10A, Eight Outlets, 50kA PP10A8-50
Surge Filter Plug In, 10A, Eight Outlets, 19" Rack Style PP10A8-19
16-703
16.1. Power Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.1.6. Surge Filters
PP Plug-in Surge Filters 15A and Rack Mount
Novaris plug-in surge filters plug into Australian 15A outlet sockets and provide premium protection for sensitive electronic equipment.
PP15
A1-1
9
PP15
A1-5
0
PP10
A8-1
9
Electrical Specifications
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Nominal voltage U0 230V / 50Hz
Maximum continuous voltage Uc 275V / 50Hz
Maximum discharge current (8/20µs) Imax 19kA 50kA 19kA
Maximum load curent IL 15A 10A
Protection stages Metal oxide varistor / LC filter / metal oxide varistor
Voltage protection level @ 3kA (8/20µs) Up <360V
Response time tA Instantaneous
Earth leakage current <200µA
Maximum voltage drop (% of U0) DU <1%
Display LED power and status LED Status
Dimensions
Width 170mm 484mm
Height 100mm 44mm
Depth 60mm 220mm
Product Series IL Imax Plug type Outlets
PP 15 A 1 - 19
Standards Compliance
IEC 61643-1 class III
AS/NZS 1768 category A
IEEE C62.41 category A
BS 6651 category A
CP 33 category A
IEC 1000-4-5
UL1449 third edition
IEC
order codes
Description code
Surge Filter Plug In, 15A, Single Outlet, 19kA PP15A1-19
Surge Filter Plug In, 15A, Single Outlet, 50kA PP15A1-50
Surge Filter Plug in, 10A, Eight Outlets, 19” Rack Style PP10A8-19
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection
For your information:NSW & VIC only
16
16.2. Process Control ProtectionSelecting Process Control Protection
1. Provide adequate protection for all equipment.2. Achieve a long working life.3. Allow the signal to pass under normal operation.4. Optimise the cost and size of the surge protection devices (SPDs).
Two port SPDs are connected in series with the line. Almost all Novaris process control SPDs incorporate this configuration where a low let through voltage, (Up) is always required to adequately protect low level signals.
Novaris process control SPDs contain a combination of voltage switching components comprising gas discharge tubes, series impedances and voltage limiting components comprising MOVs and suppressor diodes.
The selection of SPDs for process control requires more attention than the selection of power line SPDs to ensure the signal is not attenuated or lost through the SPD. Novaris manufactures process control SPDs for almost all applications and can design custom solutions for unique applications.
1. Determine the signalling protocol and peak line voltage
Table 1 on page 60 provides common signalling protocols and the appropriate Novaris SPD for each application. Even if the actual protocol is unknown the peak signal voltage must be determined.
2. Select the clamping voltage
The clamping voltage of the SPD must be greater than the peak signalling voltage. The following is a guide.
3. Determine the signal current
Standard SL models are rated at IL = 250mA. For current up to IL = 6A use the SSP6A series. For higher current applications, consider using SFD surge filters.
4. Select signal frequency / data rate
Standard SL series will pass signals up to 250kHz. For higher frequency / faster data rates consider the SL485 or SL-DH.
5. consider earth isolation
The normal SL DIN rail base, designated -G, connects the protective earth to the DIN rail to provide a low impedance earth path. If the earth must be isolated, for example with instrument loops, use the -EC90 base.
U
Z
Z
Nominal Peak Signal Voltage (V) Power System (V) Clamping Voltage (V)
0-6 6 7v5
6-15 12 18
15-30 24 36
30-60 48 68
Process control protection must:
Options for Surge Protection Devices
Selection of Surge Protection Devices
16-705
16.2. Process Control ProtectionFor your Information:NSW & VIC only
16
Selecting Process Control Protection
table 1 outlines some of the most common signalling protocols along with the Novaris surge protection product best suited to your application. For other signalling protocols please contact Novaris to discuss your protection requirements.
Table 1. Signalling Protocols.
Signal Type novaris Product
5V SL7v5-G6V SL7v5-G12V SL18-G24V SL36-G0-5V SL7v5-G0-10V SL18-G0-20V SL36-G±10V SL18-G0-20mA SL420-G4-20mA SL420-G10Base2 CLB-MF-1010BaseT UTP-RJ45-xCAT6100BaseT UTP-RJ45-xCAT61000BaseT UTP-RJ45-xCAT6BitBus DB9-RS485CAN - high speed SL485-EC90CAN - low speed SL485-EC90CCTV CLB-MF-10ControlNet CLB-MF-10Data Highway SL-DH-EC90Data Highway Plus SL-DH-EC90DeviceNet (signal pair) SL7v5-GDupline (signal pair) SL7v5-GFIP Bus SL485-EC90Foundation Fieldbus SSP6A-38-GHART SL420-GInterbus SL485-EC90ISDN SL-PTSN-G, KP1, KP10, MPP-RJ12, MPP-RJ45Load cells LCP-36P-Net SL485-EC90Power over Ethernet UTP-RJ45-xPoEProcess Bus (P-Bus) SL485-EC90Profibus DP SL485-EC90Profibus FMS SL485-EC90Profibus PA SSP6A-38-GPTSN SL-PTSN-G, KP1, KP10, MPP-RJ12, MPP-RJ45RS232 DB9-RS232, DB25-RS232RS422 2x SL485-EC90, DB9-RS485RS432 2x SL485-EC90, DB9-RS485RS485 2x SL485-EC90, DB9-RS485V.10 2x SL485-EC90, DB9-RS485V.11 2x SL485-EC90, DB9-RS485V.24 SL36-EC90, DB9-RS232, DB25-RS232V.35 SL485-EC90WorldFIP SSP6A-38-GX.21 SL36-EC90, DB9-RS232, DB25-RS232DSL SL-PTSN-G, KP1, KP10, MPP-RJ12, MPP-RJ45
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.2.1. Twisted Pair Signal Protection
SL Slimline Signal Line Protectors
Novaris SL range of plug-in signal line protectors provide surge protection for most twisted pair signalling schemes. Ideal for the protection of PLCs, fire and security systems, telecommunications and telemetry systems, railway signalling, SCADA and other industrial monitoring and control equipment.
Electrical Specifications
Connection type Series
Modes of protection Transverse and common mode
Maximum continuous voltage (DC) U0 7V 16V 34V 65V 200V 200V
Maximum continuous voltage (AC) Uc 5V 11V 24V 46V 140V 140V
Discharge current 8/20µs Imax 10kA
Maximum load current IL 250mA 180mA
Impulse voltage 1.2/50µs Up 8V 19V 40V 76V 235V 30V
Impulse durability C2 8/20µs, 5kA, 10 times
AC durability 1 Arms, 1s, 5 times
Overstessed fault mode Mode 3
Line resistance 9W 8.2W 17W
Dimensions
Width 7mm
Height 102mm
Depth 68mm
SL7v
5
SL18
SL36
SL68
SL-P
STN
SL-iS
witc
h
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
A-tick (PSTN & iSwitch)
Product Series Base optionTop
SL 7v5 - [*]
IEC
order codes
Description code
Module Only (Without Base)
1 Pair (Signal Types 5V,6V,0-5V, DeviceNet & Dupline) Protection SL7v5
1 Pair (Signal Types 12V,0-10V & +/-10V) Protection SL18
1 Pair (Signal Types 24V & 0-20V) Protection SL36
1 Pair (Signal Types up to 65VDC / 46VAC) Protection SL68
1 Pair (Signal Type ISDN & DSL) Protection SL-PSTN
1 Pair (Signal Types 200VDC / 140VAC) Protection SL-iSwitch
Module c/w Base
1 Pair (Signal Types 5V,6V,0-5V. DeviceNet & Dupline) Protection SL7v5-g
1 Pair (Signal Types 12V,0-10V & +/-10V) Protection SL18-g
1 Pair (Signal Types 24V & 0-20V) Protection SL36-g
1 Pair (Signal Types up to 65VDC / 46VAC) Protection SL68-g
1 Pair (Signal Type ISDN & DSL) Protection SL-PSTN-G
1 Pair (Signal Types 200VDC / 140VAC) Protection SL-iSwitch-G
Module c/w 90V Earth Clamp Base
1 Pair (Signal Types 5V,6V,0-5V. DeviceNet & Dupline) Protection SL7v5-EC90
1 Pair (Signal Types 12V,0-10V & +/-10V) Protection SL18-EC90
1 Pair (Signal Types 24V & 0-20V) Protection SL36-EC90
1 Pair (Signal Types up to 65VDC / 46VAC) Protection SL68-EC90
1 Pair (Signal Type ISDN & DSL) Protection SL-PSTN-EC90
1 Pair (Signal Types 200VDC / 140VAC) Protection SL-iSwitch-EC90
Accessories
Description code
Base with Ground Connection SLDIN-G
Base with 90V Isolation to Base SLDIN-EC90
Earth Comb, 9x Contact, 2 x 6.3mm Spade Terminals SL-COMB
16-707
16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.2.1. Twisted Pair Signal Protection
SL Slimline Signal Line Protectors
Novaris SL range of plug-in signal line protectors provide surge protection for most twisted pair signalling schemes. Ideal for the protection of PLCs, fire and security systems, telecommunications and telemetry systems, railway signalling, SCADA and other industrial monitoring and control equipment.
Electrical Specifications
Connection type Series
Modes of protection Transverse and common mode
Maximum continuous voltage (DC) U0 8V 34V 8V 34V
Maximum continuous voltage (AC) Uc 6V 24V 6V -
Discharge current 8/20µs Imax 10kA
Maximum load current IL 250mA 30mA
Impulse voltage 1.2/50µs Up 15V 50V 15V 40V
Impulse durability C2 8/20µs, 5kA, 10 times
AC durability 1 Arms, 1s, 5 times -
Overstressed fault mode Mode 3
Line resistance 3.9W 8.2W
Display - LED Status
Dimensions
Width 7mm
Height 102mm
Depth 68mm
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
SL48
5-EC
90
SL-D
H
SL-R
TD
SL-4
20
Product Series Base optionTop
SL 485 - [*]
IEC
order codes
order codes
Description code
Module c/w 90V Earth Clamp Base
1 Pair RS485 (ProfiBus-DP, FIP Bus, ProfiBus-FMS, InterBus, CAN, ASCII, Modbus) Protection SL485-EC90
1 Pair Data Highway / Data Highway Plus Protection SL-DH-EC90
Module c/w Base
1 Pair RTD Protection SL-RTD-G
1 Pair 0/4 to 20mA (HART as well) Protection SL-420-G
Description code
Base with Ground Connection SLDIN-G
Base with 90V Isolation to Base SLDIN-EC90
Earth Comb, 9x Contact, 2 x 6.3mm Spade Terminals SL-COMB
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.2.1. Twisted Pair Signal Protection
SSP Slimline Series Surge Protectors
Novaris SL range of plug-in signal line protectors provide surge protection for power supplies with loads up to 6A. Ideal for the protection of PLCs, fire and security systems, telecommunications and telemetry systems, railway signalling, SCADA and other industrial monitoring and control equipment.
Electrical Specifications
Connection type Series
Modes of protection Transverse and common mode
Maximum continuous voltage (DC) U0 14V 26V 38V 65V 170V
Maximum continuous voltage (AC) Uc 11V 20V 30V 50V 130V
Maximum discharge current (8/20µs) Imax 9.6kA 3.6kA
Maximum load current IL 6A
Voltage protection level @ 5kV (10/700µs) Up 26V 52V 70V 120V 250V
Line resistance 0W
3dB Frequency @ 50W 100kHz
Dimensions
Width 7mm
Height 102mm
Depth 68mm
SSP6
A-14
SSP6
A-26
SSP6
A-38
SSP6
A-65
SSP6
A-13
0
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
Product Series IL Uc
SSP 6A - 14
IEC
order codes
Description code
Module Only (Without Base)
Series Surge Protector, 14VDC / 11VAC Peak SSP6A-14
Series Surge Protector, 26VDC / 2oVAC Peak SSP6A-26
Series Surge Protector, 38VDC / 30VAC Peak (Foundation Fieldbus, Profibus PA & World FIP)
SSP6A-38
Series Surge Protector, 65VDC / 50VAC Peak SSP6A-65
Series Surge Protector, 170VDC / 130 VAC Peak SSP6A-130
Module c/w G Base
Series Surge Protector, 14VDC / 11VAC Peak SSP6A-14-g
Series Surge Protector, 26VDC / 2oVAC Peak SSP6A-26-g
Series Surge Protector, 38VDC / 30VAC Peak (Foundation Fieldbus, Profibus PA & World FIP)
SSP6A-38-g
Series Surge Protector, 65VDC / 50VAC Peak SSP6A-65-G
Series Surge Protector, 170VDC / 130 VAC Peak SSP6A-130-G
Module c/w 90V Earth Clamp Base
Series Surge Protector, 14VDC / 11VAC Peak SSP6A-14-EC90
Series Surge Protector, 26VDC / 2oVAC Peak SSP6A-26-EC90
Series Surge Protector, 38VDC / 30VAC Peak (Foundation Fieldbus, Profibus PA & World FIP)
SSP6A-38-EC90
Series Surge Protector, 65VDC / 50VAC Peak SSP6A-65-EC90
Series Surge Protector, 170VDC / 130 VAC Peak SSP6A-130-EC90
Accessories
Description code
Base with Ground Connection SLDin-g
Base with 90V Isolation to Base SLDIN-EC90
Earth Comb, 9x Contact, 2 x 6.3mm Spade Terminals SL-COMB
16-709
16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
order codes
Description code1 Line Signal Protector 7V Peak SLD1-7v51 Line Signal Protector 18V Peak SLD1-181 Line Signal Protector 36V Peak SLD1-361 Line Signal Protector 68V Peak SLD1-681 Line Signal Protector PSTN SLD1-PSTN1 Line Signal Protector RS485 SLD1-RS4851 Line Signal Protector DH485 SLD1-DH2 Line Signal Protector 7V Peak SLD2-7v52 Line Signal Protector 18V Peak SLD2-182 Line Signal Protector 36V Peak SLD2-362 Line Signal Protector 68V Peak SLD2-682 Line Signal Protector PSTN SLD2-PSTN2 Line Signal Protector RS485 SLD2-RS4852 Line Signal Protector DH485 SLD2-DH4 Line Signal Protector 7V Peak SLD4-7v54 Line Signal Protector 18V Peak SLD4-184 Line Signal Protector 36V Peak SLD4-364 Line Signal Protector 68V Peak SLD4-684 Line Signal Protector PSTN SLD4-PSTN4 Line Signal Protector RS485 SLD4-RS4854 Line Signal Protector DH485 SLD4-DHoptions2A Version 2High Frequency HIsolated Base I
16.2.2. High Current Signal Line Protectors
SLD - hardwired
Novaris hardwired high energy multistage transient protection for highly exposed circuits.
SLD1
SLD2
SLD4
Electrical Specifications
Connection type Series
Modes of protection Transverse and common modes
Number of pairs 1 2 4
Maximum discharge current (8/20µs) Imax 20kA
Protection stages Multistage
Dimensions
Width 19.5mm 29mm 49mm
Height 95mm
Depth 78mm
Standards Compliance
ITU-T K.44
AS/NZS 1768
AS4117
BS 6651
CP 33
IEC 61643-21
UL497B
A-tick
IEC
Product Series Pairs Signal Type
SLD 1 - [SIG]
PSTN
DH48
5
RS48
5
7v5
18 36 68
Signal Type [SIG] Electrical Specifications
Maximum Continuous Voltage (DC) Uc 200V 34V 8V 7V 18V 36V 68VMaximum Continuous Voltage (AC) Uc - 24V 6V 5V 11V 24V 46VImpulse Voltage 1.2/50µs Up - 50V 15V 8V 19V 40V 76VVoltage Protection Level @ 1kV/µs Up <130V -Maximum Load Current IL 250mA 500mA 250mALine Resistance 8.2W 3.9W 8.2W3dB Frequency @ 50W 20MHz 10Mhz 250kHz
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.2.3. Multiline Signal Protection
SLM Multiline Protectors
Novaris SLM offers protection for up to 12 signal lines. Typical applications include process control, telemetry, PLC, and irrigation systems.
order codes
Description code
12 Line Signal Protector 7VDC / 5VAC Peak SLM-7v5
12 Line Signal Protector 16VDC / 11VAC Peak SLM-18
12 Line Signal Protector 34VDC / 24VAC Peak SLM-36
12 Line Signal Protector 65VDC / 46VAC Peak SLM-68
12 Line Signal Protector 200VDC / 140VAC Peak SLM-200
SLM
-7v5
SLM
-18
SLM
-36
SLM
-68
SLM
-200
Electrical Specifications
Connection type Series
Modes of protection Transverse and common mode
Number of lines 12
Maximum continuous voltage (DC) Uc 7V 16V 34V 65V 200V
Maximum continuous voltage (AC) Uc 5V 11V 24V 46V 140V
Discharge current 8/20µs Imax 20kA
Protection stages Multistage
Maximum load current IL 350mA (2A for option 2; 500mA for option H)
Impulse voltage 10/700µs Up 8V 19V 40V 76V 235V
Line resistance - base 8.2W
Line resistance - 2A 0.1W
Line resistance - high frequency 3.9W
Maximum frequency fc 250kHz (25MHz high frequency option)
Dimensions
Width 128mm
Height 80mm
Depth 42mm
Standards Compliance
IEC61643-21
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
UL497B
SLM - 7v5
Product Series Uc
IEC
16-711
16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.2.4. Serial Port Protection
rS Serial Port Protectors
Novaris RS Protectors provide protection for serial protocol systems in RS232 and RS485 applications. These units are housed in a headshell enclosure.
order codes
Description code
RS232 Protector, DB9 Headshell DB9-RS232
RS232 Protector, DB25 Headshell DB25-RS232
RS422/RS485 Protector, DB9 Headshell DB9-RS485
DB9-
RS23
2
DB25
-RS2
32
DB9-
RS48
5
Electrical Specifications
Connection type Series
Modes of protection Transverse and common
Maximum continuous voltage Uc 36V 8.2V
Discharge current 8/20µs Imax 250A
Protection stages SAD and GDT
Number of lines 8
Impulse voltage 10/700µs Up 40V 14V
Signalling protocol RS232 RS485
Dimensions
Width 34mm 56mm 34mm
Height 17mm
Depth 63mm
DB 9 - RS232
Product Series Signalling ProtocolConnector
Standards Compliance
IEC61643-21
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
UL497B
IEC
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.2. Process Control Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.2.5. Load Cell Protection
LcP Load cell Protector
The Novaris LCP provides protection for both 4-wire and 6-wire loadcells as well as the measuring instrument. The LCP is contained within an IP65 enclosure, or alternatively as a PCB only. Installation of the LCP is certified and does not affect weighbridge calibration.
order codes
Description code
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Enclosed 12V System LCP-18
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Non Enclosed 12V System LCP-18-PCB
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Enclosed 24V System LCP-36
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Non Enclosed 24V System LCP-36-PCB
LCP-
18
LCP-
36
LCP-
18-P
CB
LCP-
36-P
CB
Electrical Specifications
Connection type Series
Modes of protection Transverse and common mode
Maximum continuous voltage (DC) Uc 18V 36V 18V 36V
Maximum discharge current (8/20µs) Imax 250A
Protection stages SAD and GDT
Maximum load current IL 6.5A 5A
Lines protected 4 or 6
Dimensions
Width 116mm 76mm
Height 65mm 63mm
Depth 56mm 20mmStandards Compliance
IEC61643-21
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
UL497B
NSC No: S366
IEC
LCP - 36 - PCB
Product Series Option Uc
16-713
16.3. LAN & CCTV Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.3. LAN & CCTV Protection16.3.1. Coaxial CCTV Protection
cL coaxial cctV Protectors
Novaris Coaxial CCTV protectors are suited to the protection of security and CCTV applications.
order codes
Description code
BNC Male / BNC Female, 10V Peak Voltage CLB-MF-10
BNC Female / BNC Female, 10V Peak Voltage CLB-FF-10
BNC Female / BNC Male, 10V Peak Voltage CLB-FM-10
F Type Female / F Female, 10V Peak Voltage CLF-FF-10
BNC Male / BNC Female, 18V Peak Voltage CLB-MF-18
BNC Female / BNC Female, 18V Peak Voltage CLB-FF-18
BNC Female / BNC Male, 18V Peak Voltage CLB-FM-18
F Type Female / F Female, 18V Peak Voltage CLF-FF-18
CLB
-MF-
10
CLB
-FF-
10
CLB
-FM
-10
CLF
-FF-
10
CLB
-MF-
18
CLB
-FF-
18
CLB
-FM
-18
CLF
-FF-
18
Standards Compliance
ITU-T K.44
AS/NZS 1768
BS 6651
IEEE C62.41
CP 33
IEC 61643-21
UL497B
Electrical Specifications
Connection type Series
Modes of protection Transverse and common modes
Maximum continuous voltage Uc 8.2V 18V
Maximum discharge current (8/20µs) Imax 20kA
Maximum load current IL 500mA
Protection stages Multistage
Voltage protection level @ 5kV (10/700µs)
Up 14V 20V
3dB frequency 20MHz
Insertion loss <1dB @ 20MHz
Dimensions
Width 26mm
Height 26mm
Depth 89mm 86mm 86mm 88mm 89mm 86mm 86mm 88mm
Product Series UcConnector Gender LineGender EQPT
CL B - M F - 10
IEC
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.3. LAN & CCTV Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.3.1. Coaxial CCTV Protection
cL coaxial cctV Protectors
Novaris Coaxial CCTV protectors are suited to the protection of security and CCTV applications.
order codes
Description code
BNC Male / BNC Female, 36V Peak Voltage CLB-MF-36
BNC Female / BNC Female, 36V Peak Voltage CLB-FF-36
BNC Female / BNC Male, 36V Peak Voltage CLB-FM-36
F Type Female / F Female, 36V Peak Voltage CLF-FF-36
CLB
-MF-
36
CLB
-FF-
36
CLB
-FM
-36
CLF
-FF-
36
Electrical Specifications
Connection type Series
Modes of protection Transverse and common modes
Maximum continuous voltage Uc 36V
Maximum discharge current (8/20µs) Imax 20kA
Maximum load current IL 500mA
Protection stages Multistage
Voltage protection level @ 5kV (10/700µs) Up 40V
3dB frequency 20MHz
Insertion loss <1dB @ 20MHz
Dimensions
Width 26mm
Height 26mm
Depth 89mm 86mm 86mm 88mm
Standards Compliance
ITU-T K.44
AS/NZS 1768
BS 6651
IEEE C62.41
CP 33
IEC 61643-21
UL497B
Product Series UcConnector Gender LineGender EQPT
CL B - M F - 36
IEC
16-715
16.3. LAN & CCTV Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.3.2. CCTV Protection
SFD Combined Power and Signal Protectors
Novaris protection for both power and signal is provided in one compact and economical DIN compliant package. Ideal for security and CCTV camera protection.
order codes
Description code
Combined Surge Protector, 2A, 30V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-2-2-30-C
Combined Surge Protector, 6A, 30V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-6-2-30-C
Combined Surge Protector, 2A, 50V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-2-6.5-50-C
Combined Surge Protector, 6A, 50V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-6-6.5-50-C
Combined Surge Protector, 2A, 130V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-2-6.5-130-C
Combined Surge Protector, 6A, 130V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-6-6.5-130-C
Combined Surge Protector, 2A, 275V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-2-6.5-275-C
Combined Surge Protector, 6A, 275V Surge Filter, BNC Female / BNC Female, 10V Clamp SFD1-6-6.5-275-C
SFD1
-2-2
-30-
C
SFD1
-6-2
-30-
C
SFD1
-2-6
.5-5
0-C
SFD1
-6-6
.5-5
0-C
SFD1
-2-6
.5-1
30-C
SFD1
-6-6
.5-1
30-C
SFD1
-2-6
.5-2
75-C
SFD1
-6-6
.5-2
75-C
Power Line Protection
Connection type Series
Modes of protection All mode (L-N, L-PE, N-PE)
Nominal voltage U0 24V / 50Hz 40V / 50Hz 110V / 50Hz 230V / 50Hz
Maximum continuous voltage Uc 30V / 50Hz 50V / 50Hz 130V / 50Hz 275V / 50Hz
Phases 1
Maximum discharge current (8/20µs) Imax 2kA 6.5kA
Maximum load current IL 2A 6A 2A 6A 2A 6A 2A 6A
Protection stages Metal oxide varistor / LC filter / metal oxide varistor
Voltage protection level @ 3kA (8/20µs)
Up <50V <150V <450V <750V
Response time tA Instantaneous
Earth leakage current <500uA
Maximum voltage drop (% of U0) DU <1%
Signal Line Protection
Connection type Series
Modes of protection Transverse and common modes
Maximum continuous voltage Uc 8.2V
Maximum discharge current (8/20µs) Imax 20kA
Maximum load current IL 500mA
Protection stages Gas discharge tube / series impedance / SAD
Impulse voltage 1.2/50µs Up 14V
3dB frequency 20MHz
Insertion loss <1dB @ 20MHz
Dimensions
Width 28mm
Height 116mm
Depth 78mm
Standards Compliance
IEC 61643-1 class II, III
AS/NZS 1768 categories A, B
IEEE C62.41 categories A, B
BS 6651 categories A, B
CP 33 categories A, B
IEC 1000-4-5
UL1449 third edition
ITU-T K.44
IEC 61643-21
UL497B
Product Series CCTVPhase Uc IL Imax
SFD 1 - 2 - 2 - 30 - C
IEC
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.3. LAN & CCTV Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.3.3. LAN Protection
RJ45 UTP Network Protectors - Terminal
Novaris RJ45 terminal protectors are compliant with 1000BaseT (gigabit Ethernet), CAT6 and power over ethernet applications.
order codes
Description code
1 Port, RJ45 Connectors for 1000 BaseT, CAT5e & CAT6 utP-rJ45-1cAt6
8 Port, RJ45 Connectors for 1000 BaseT, CAT5e & CAT6 utP-rJ45-8cAt6
16 Port, RJ45 Connectors for 1000 BaseT, CAT5e & CAT6 utP-rJ45-16cAt6
24 Port, RJ45 Connectors for 1000 BaseT, CAT5e & CAT6 UTP-RJ45-24CAT6
1 Port, RJ45 Connectors for POE Applications, CAT5 utP-rJ45-1Poe
8 Port, RJ45 Connectors for POE Applications, CAT5 utP-rJ45-8Poe
16 Port, RJ45 Connectors for POE Applications, CAT5 UTP-RJ45-16PoE
24 Port, RJ45 Connectors for POE Applications, CAT5 UTP-RJ45-24PoE
UTP
-RJ4
5-1C
AT6
UTP
-RJ4
5-8C
AT6
UTP
-RJ4
5-16
CAT
6
UTP
-RJ4
5-24
CAT
6
UTP
-RJ4
5-1P
oE
UTP
-RJ4
5-8P
oE
UTP
-RJ4
5-16
PoE
UTP
-RJ4
5-24
PoE
Electrical Specifications
Connection type Series
Modes of protection Transverse and common modes
Lines protected All
Maximum continuous voltage Uc 6VDC 6VDC, 230VDC
Maximum discharge current (8/20µs) Imax 10kA
Protection stages Multistage Multistage
Voltage protection level @ 5kV (10/700µs)
Up <20V
Maximum frequency fc 250MHz
Dimensions
Width 26mm 483mm 26mm 483mm
Height 26mm 89mm 26mm 89mm
Depth 85mm 80mm 85mm 80mm
Standards Compliance
100BaseT
1000BaseT (excluding PoE models)
CAT5 (excluding PoE models)
CAT5e (excluding PoE models)
CAT6 (excluding PoE models)
TIA/EIA 568A
TIA/EIA 568B
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
Product Series Connector Circuits
UTP - RJ45 - 1CAT6
IEC
16-717
16.4. Coaxial ProtectionFor your Information:NSW & VIC only
16
16.4. Coaxial ProtectionSelecting Coaxial Protection
1. Provide adequate protection for all equipment.2. Achieve a long working life.3. Allow the signal to pass under normal operation and not have an adverse affect on insertion loss and return loss.4. Optimise the cost and size of the surge protection devices (SPDs).
Novaris manufacturers two types of RF coaxial SPDs. Those containing a gas discharge tube (GDT) are suitable for a wide frequency range but must be chosen carefully taking into account the power on the line if used for a transmitting application. Quarter wave stub protectors offer exceptionally low let through voltages but are frequency sensitive. Their power handling capability is only limited by the rating of the coaxial connectors employed.
Selection of Surge Protection Devices
1. identify the connector type
Novaris manufactures a range of coaxial SPDs to suit most common connectors and gender variations.
2. Select the clamping voltage
The clamping voltage of the SPD must be greater than the peak voltage on the line. This is particularly important when used for transmitting applications. The following is a guide.
3. Identify the maximum operating frequency
For standard models using N-type connectors the maximum frequency is 2GHz. 3G models feature replaceable GDTs and will operate to 3GHz. For other variations the upper frequency is dependent upon the connector type.
4. tuned stub protectors
For narrow bandwidth applications where no DC voltage is injected, tuned stub protectors provide exceptionally low let through voltages and very low intermodulation products. The centre operating frequency must be specified when ordering.
Power in 50W (W) GDT Voltage (V)
0-40 90
40-125 230
125-300 350
300-800 600
800-2000 1000
Coaxial line surge protection must:
Options for Surge Protection Devices
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.4. Coaxial Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
RF Equipment Protection up to 3GHz
Novaris gas discharge surge protectors are capable of passing RF signals to 3GHz (limited by connector type). N-type female / female protectors are suitable for bulkhead mounting.
order codes
Accessories
Description code
N-Type Male to N-Type Female to 3GHz Bulkhead with 90V Peak Voltage CN-MF-90-3
SMA Type Female to SMA Female to 3GHz Bulkhead with 90V Peak Voltage CN-FF-90-3
N-Type Male to N- Type Female to 3GHz Bulkhead with 230V Peak Voltage CN-MF-230-3
SMA Type Female to SMA Female to 3GHz Bulkhead with 230V Peak Voltage CN-FF-230-3
N-Type Male to N- Type Female to 3GHz Bulkhead with 350V Peak Voltage CN-MF-350-3
SMA Type Female to SMA Female to 3GHz Bulkhead with 350V Peak Voltage CN-FF-350-3
Description code
Mounting Bracket with Sealing Kit M1
Mounting Bracket M
DIN Clip Mount D
Earth Stud ES
Electrical Specifications
Connection type Series
Modes of protection Signal-Earth
Sparkover voltage Uc 90VDC 230VDC 350VDC
Maximum discharge current (8/20µs) Imax 20kA
Power rating 0 - 40W 40 - 125W 125 - 300W
Maximum working frequency fc 3GHz
Voltage protection level @ 3kA (8/20µs) UP <650V <820V <1.1kV
Characteristic impedance 50W (75W F-type only)
VSWR <1.1:1
Return loss >26dB
Insertion loss <0.2dB
Dimensions
Configuration CB-MF CB-FF CD-MF CD-FF CF-FF CN-MF CN-FF CU-MF CU-FF CT-MF CT-FF
Width 26mmØ40mm Ø40mm
26mm
Height 26mm 26mm
Maximum length 64mm 61mm 70mm 73mm 57mm 64mm 72mm 57mm 80mm
CN
-MF-
90-3
CN
-FF-
90-3
CN
-MF-
230-
3
CN
-FF-
230-
3
CN
-MF-
350-
3
CN
-FF-
350-
3
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
Product Series OptionsConnector fcGender Uc
C N - FF - 90 - 3 - [M]
IEC
16.4.1. RF Equipment Protection
16-719
16.4. Coaxial Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
Product Series OptionsConnector fcGender Uc
C N - FF - 600 - 3 - [D]
IEC
RF Equipment Protection up to 3GHz
Novaris gas discharge surge protectors are capable of passing RF signals to 3GHz (limited by connector type). N-type female / female protectors are suitable for bulkhead mounting.
CN
-MF-
600-
3
CN
-FF-
600-
3
CN
-MF-
1000
-3
CN
-FF-
1000
-3
Electrical Specifications
Connection type Series
Modes of protection Signal-Earth
Sparkover voltage Uc 600VDC 1000VDC
Maximum discharge current (8/20µs) Imax 20kA
Power rating 300 - 800W 800 - 1000W
Maximum working frequency fc 3GHz
Voltage protection level @ 3kA (8/20µs) UP <1.3kV <1.5kV
Characteristic impedance 50W (75W F-type only)
VSWR <1.1:1
Return loss >26dB
Insertion loss <0.2dB
Dimensions
Configuration CB-MF CB-FF CD-MF CD-FF CF-FF CN-MF CN-FF CU-MF CU-FF CT-MF CT-FF
Width 26mmØ40mm Ø40mm
26mm
Height 26mm 26mm
Maximum length 64mm 61mm 70mm 73mm 57mm 64mm 72mm 57mm 80mm
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
order codes
Accessories
Description code
N-Type Male to N- Type Female to 3GHz Bulkhead with 600V Peak Voltage CN-MF-600-3
SMA Type Female to SMA Female to 3GHz Bulkhead with 600V Peak Voltage CN-FF-600-3
N-Type Male to N- Type Female to 3GHz Bulkhead with 1000V Peak Voltage CN-MF-1000-3
SMA Type Female to SMA Female to 3GHz Bulkhead with 1000V Peak Voltage CN-FF-1000-3
Description code
Mounting Bracket with Sealing Kit M1
Mounting Bracket M
DIN Clip Mount D
Earth Stud ES
16.4.1. RF Equipment Protection
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.4. Coaxial Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.4.1. RF Equipment Protection
Electrical Specifications
Connection type Series
Modes of protection Signal-Earth
Sparkover voltage Uc 90VDC 230VDC 350VDC
Maximum discharge current (8/20µs) Imax 20kA
Power rating 0 - 40W 40 - 125W 125 - 300W
Maximum working frequency fc 6GHz
Voltage protection level @ 3kA (8/20µs) UP <650V <820V <1.1kV
Characteristic impedance 50W
VSWR <1.1:1
Return loss >26dB
Insertion loss <0.2dB
Dimensions
Width 26mm
Height 26mm
Maximum length 69mm
CN
-MF-
90-6
CN
-FF-
90-6
CN
-MF-
230-
6
CN
-FF-
230-
6
CN
-MF-
350-
6
CN
-FF-
350-
6
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
Product Series fcConnector UcGender
C N - FF - 90 - 6
IEC
RF Equipment Protection up to 6GHz
Novaris gas discharge surge protectors are capable of passing RF signals to 6GHz (limited by connector type). N-type female / female protectors are suitable for bulkhead mounting.
order codes
Description code
N-Type Female to N- Type Female to 6GHz Bulkhead with 90V Peak Voltage CN-MF-90-6
N-Type Male to N- Type Female to 6GHz Bulkhead with 90V Peak Voltage CN-FF-90-6
N-Type Female to N- Type Female to 6GHz Bulkhead with 230V Peak Voltage CN-MF-230-6
N-Type Male to N- Type Female to 6GHz Bulkhead with 230V Peak Voltage CN-FF-230-6
N-Type Female to N- Type Female to 6GHz Bulkhead with 350V Peak Voltage CN-MF-350-6
N-Type Male to N- Type Female to 6GHz Bulkhead with 350V Peak Voltage CN-FF-350-6
Accessories
Description code
Mounting Bracket with Sealing Kit M1
Mounting Bracket M
DIN Clip Mount D
Earth Stud ES
16-721
16.4. Coaxial Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.4.1. RF Equipment Protection
CN
-MF-
600-
6
CN
-FF-
600-
6
CN
-MF-
1000
-6
CN
-FF-
1000
-6
Electrical Specifications
Connection type Series
Modes of protection Signal-Earth
Sparkover voltage Uc 600VDC 1000VDC
Maximum discharge current (8/20µs) Imax 20kA
Power rating 300 - 800W 800 - 1000W
Maximum working frequency fc 6GHz
Voltage protection level @ 3kA (8/20µs) UP <1.3kV <1.5kV
Characteristic impedance 50W
VSWR <1.1:1
Return loss >26dB
Insertion loss <0.2dB
Dimensions
Width 26mm
Height 26mm
Maximum length 69mm
Product Series fcConnector UcGender
C N - FF - 600 - 6
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
IEC
RF Equipment Protection up to 6GHz
Novaris gas discharge surge protectors are capable of passing RF signals to 6GHz (limited by connector type). N-type female / female protectors are suitable for bulkhead mounting.
order codes
Description code
N-Type Female to N- Type Female to 6GHz Bulkhead with 600V Peak Voltage CN-MF-600-6
N-Type Male to N- Type Female to 6GHz Bulkhead with 600V Peak Voltage CN-FF-600-6
N-Type Female to N- Type Female to 6GHz Bulkhead with 1000V Peak Voltage CN-MF-1000-6
N-Type Male to N- Type Female to 6GHz Bulkhead with 1000V Peak Voltage CN-FF-1000-6
Accessories
Description code
Mounting Bracket with Sealing Kit M1
Mounting Bracket M
DIN Clip Mount D
Earth Stud ES
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.4. Coaxial Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.4.1. RF Equipment Protection
RF Equipment Protection Tuned Stub
Novaris tuned stub surge protectors employ quarter-wavelength short circuit stub technology. Suitable for narrow bandwidth applications where no DC voltage is injected. RF power and surge rating are limited by the cables and connectors only.
CST
UB-
D-M
F-90
0
CST
UB-
D-FF
-900
CST
UB-
N-M
F-90
0
CST
UB-
N-F
F-90
0
CST
UB-
D-M
F-24
00
CST
UB-
D-FF
-240
0
CST
UB-
N-M
F-24
00
CST
UB-
N-F
F-24
00
Electrical Specifications
Connection type Series
Modes of protection Signal-Earth
Maximum discharge current (8/20µs) Imax 50kA
Power rating Limited only by connectors and cables used.
Tuned frequency range tf 400MHz to 3GHz (specify)
Voltage protection level @ 3kA (8/20µs)
UP <20V
Characteristic impedance 50W
Bandwidth ±10% of tuned frequency
VSWR <1.1:1 within bandwidth
Return loss >26dB within bandwidth
Insertion loss <0.1dB at tuned bandwidth
Dimensions
Body diameter 32mm
Height Depends upon operating frequency
Maximum length 63mm 60mm 56mm 54mm 63mm 60mm 56mm 54mm
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
Product Series tfConnector Gender
CSTUB - N - MF - 2400
IEC
order codes
Description code
Quarter Wave Stub 7/16 DIN Male / 7/16 DIN Female, 900MHz Tuned Frequency CSTUB-D-MF-900
Quarter Wave Stub 7/16 DIN Female / 7/16 DIN Female, 900MHz Tuned Frequency CSTUB-D-FF-900
Quarter Wave Stub N Male / N Female, 900MHz Tuned Frequency CSTUB-N-MF-900
Quarter Wave Stub N Female / N Female, 900MHz Tuned Frequency CSTUB-N-FF-900
Quarter Wave Stub 7/16 DIN Male / 7/16 DIN Female, 2400MHz Tuned Frequency CSTUB-D-MF-2400
Quarter Wave Stub 7/16 DIN Female / 7/16 DIN Female, 2400MHz Tuned Frequency CSTUB-D-FF-2400
Quarter Wave Stub N Male / N Female, 2400MHz Tuned Frequency CSTUB-N-MF-2400
Quarter Wave Stub N Female / N Female, 2400MHz Tuned Frequency CSTUB-N-FF-2400
16-723
16.4. Coaxial Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.4.1. RF Equipment Protection
RF Equipment Protection High Power
Novaris high power surge protectors suit applications including MF, HF and VHF transmitters to 50kW. The spark gap arrester has an optical arc sensor which may be used to momentarily interrupt the transmitter.
CEI
A-07
8
CEI
A-15
8
CEI
A-31
8
Electrical Specifications
Connection type Series
Modes of protection Signal-Earth
Maximum discharge current (8/20µs) Imax 100kA
Power rating >50kW limited only by coaxial cable
Surge element Spark gap, gap setting: 2mm / 10kW
Spark over voltage 2.6kV for 2mm gap
Characteristic impednce 50W
Insertion loss <0.1dB to 500MHz<0.2db to 1GHz (gap setting: 1mm)
Return loss >26dB to 500MHz>20dB to 1GHz (gap setting: 1mm)
Arc sensor Optical detector utilising photodiode, feeding transmitter interface to provide momentary shutdown
Power requirements Arc sensor: 12VDC @ 35mA
Transmission medium Arc detector fed to transmitter via optic fibre.Alternate metallic cable available.
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
Product Series OptionsConnector Size
CEIA - 078 - 1
IEC
order codes
Description code
7/8" EIA / EIA Spark Gap CEIA-078
1 5/8" EIA / EIA Spark Gap CEIA-158
3 1/8" EIA / EIA Spark Gap CEIA-318
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection
Discount code c3
Stock Status:normally stocked /Not normally stocked
For your information:NSW & VIC only
16
16.5. Telephone Protection16.5.1. KP KRONE-LSA®
KP Krone-LSA® MDF - 1 Pair / 10 Pair
The Novaris KP provides protection for KRONE-LSA® termination systems and is suitable for all twisted pair telecommunication services. The unique iSwitch technology offers the ultimate in protection against induced transients and AC induction by totally isolating the load from the incoming line during the disturbance.
order codes
Description code
KRONE-LSA Protector, 1 Pair, PSTN, 10 kA KP1
KRONE-LSA Protector, 10 Pair, PSTN 10kA KP10
KRONE-LSA Protector, 1 Pair, iSwitch Technology, 10kA KP1-i
KRONE-LSA Protector, 10 Pair, iSwitch Technology, 10kA KP10-i
KP1
KP10
KP1-
i
KP10
-i
Electrical Specifications
Connection type Series
Modes of protection Transverse and common modes
Maximum continuous voltage Uc 200VDC
Maximum discharge current (8/20µs) Imax 10kA
Maximum load current IL 350mA 180mA
Protection stages Multistage
Voltage protection level @ 1kV/µs Up <150V <30V
Maximum frequency fc 20MHz
Series resistance 8.2W 17W
Dimensions
Width 9.4mm 125mm 9.4mm 125mm
Height 21mm 18mm 21mm 18mm
Depth 36mm 42mm 36mm 42mm
Note: KRONE-LSA® is a trademark of KRONE, GmbH, Germany
Standards Compliance
ITU-T K.44
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
A-tick
KP 10 - iProduct Series iSwitchPairs
IEC
16-725
16.5. Telephone Protection
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.5.2. RJ Modular Plug Protection
RJ Modular Plug Protection
Novaris Modular Plug provides protection for twisted pair telecommunication services suitable for telephones, FAX, dial-up, ISDN and DSL modems.
order codes
Description code
PSTN Protector, RJ12 Connectors, 1 Pair MPP-rJ12-1
PSTN Protector, RJ12 Connectors, 2 Pair MPP-rJ12-2
PSTN Protector, RJ45 Connectors, 2 Pair MPP-rJ45
MPP
-RJ1
2-1
MPP
-RJ1
2-2
MPP
-RJ4
5
Electrical Specifications
Connection type Series
Modes of protection Transverse and common
Number of pairs 1 2
Maximum continuous voltage Uc 200VDC
Maximum discharge current (8/20µs) Imax 10kA
Maximum load current IL 350mA
Protection stages Multistage
Voltage protection level @ 5kV (10/700µs) Up <150V
Maximum frequency 20MHz
Series resistance 8.2W
Dimensions (enclosure only)
Width 26mm
Height 26mm
Depth 90mm
Standards Compliance
AS/NZS 4117
AS/ACIF S002
AS/NZS 60950
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC 61643-21
UL497B
A-tick
Product Series Connector Type
MPP - RJ12
IEC
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection
Discount code c3
Stock Status:normally stocked /Not normally stocked
For your information:NSW & VIC only
16
16.6.1. IS Signal Line Protectors16.6. Intrinsically Safe
iS-SL Series
The IS-SL range provides protection to any analogue and digital interface. Commonly analogue inputs and outputs are the most susceptible to damage from surge and transients induced onto the signal lines. The IS-SL range is designed exclusively for low current applications less than 350mA. For applications requiring a higher current rating Novaris recommend the IS-SSP6A range. The Novaris IS-SL range are suitable for both input and output applications.
order codes
IEC
IS-S
L7v5
IS-S
L18
IS-S
L36
IS-S
L420
Electrical Specifications
Maximum continuous voltage (DC) UO 7V 16V 34V 34V
Maximum continuous voltage (AC) Uc 5V 11V 24V 24V
Primary GDT rating 8/20us 10kA
Maximum load current IL 350mA 30mA
Signal Type Marshalling Cubicle Field / Remote
0-5V analogue IS-SL7V5-G IS-SL7V5-EC90
0-10V analogue IS-SL18-G IS-SL18-EC90
5V digital IS-SL7V5-G IS-SL7V5-EC90
12V digital IS-SL18-G IS-SL18-EC90
24V digital IS-SL36-G IS-SL7V5-EC90
0-20mA analogue IS-SL36-G/IS-SL420-G IS-SL36-EC90/IS-SL420-EC90
4-20mA analogue IS-SL36-G/IS-SL420-G IS-SL36-EC90/IS-SL420-EC90
Standards Compliance
Ex ia IIC T4 IP20
ITU(CCITT) IX K17
AS1768:2007
BS6651:1999
CP33:1996
IEEE C62.41:2002
IEC 61643-21
UL497B
Description code
Module Only (Without Base)
1 Pair (Signal Types 0-5V Analog , 5V Digital) Protection IS-SL7v5
1 Pair (Signal Types 0-10V Analog , 12V Digital) Protection IS-SL18
1 Pair (Signal Types 24V Digital, 0/4 to 20mA ) Protection IS-SL36
1 Pair (Signal Types 0/4 to 20mA) IS-SL420
Module c/w G Base
1 Pair (Signal Types 0-5V Analog , 5V Digital) Protection IS-SL7v5-G
1 Pair (Signal Types 0-10V Analog , 12V Digital) Protection IS-SL18-G
1 Pair (Signal Types 24V Digital, 0/4 to 20mA ) Protection IS-SL36-G
1 Pair (Signal Types 0/4 to 20mA) IS-SL420-G
Module c/w 90V Earth Clamp Base
1 Pair (Signal Types 0-5V Analog , 5V Digital) Protection IS-SL7v5-EC90
1 Pair (Signal Types 0-10V Analog , 12V Digital) Protection IS-SL18-EC90
1 Pair (Signal Types 24V Digital, 0/4 to 20mA ) Protection IS-SL36-EC90
1 Pair (Signal Types 0/4 to 20mA) IS-SL420-EC90
Accessories
Description code
Base with Ground Connection IS-SLDIN-G
Base with 90V Isolation to Base IS-SLDIN-EC90
16-727
16.6. Intrinsically Safe
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.6.2. IS High Speed Signal Line Protectors
iS-SL Series
High-speed data applications are catered for with the IS-SL485 and IS-SLDH models feature operation up to 20MHz. The IS-SL485 is ideal for applications such as RS485 serial communication and protocols such as Profibus and CAN. Similarly IS-SLDH is designed for other high speed protocols such as Data Highway and Data Highway Plus. Typically, these models are used in conjunction with the EC90 base to provide isolation from earth.
order codes
Description code
Module Only (Without Base)
1 Pair (Signal Types, RS485, Profibus-DP, CAN) Protection IS-SL485
1 Pair (Signal Types , Data Highway) Protection IS-SLDH
1 Pair (Signal Types, RTD ) Protection IS-SL-RTD
Module c/w G Base
1 Pair (Signal Types, RS485, Profibus-DP, CAN) Protection IS-SL485-G
1 Pair (Signal Types , Data Highway) Protection IS-SLDH-G
1 Pair (Signal Types, RTD ) Protection IS-SL-RTD-G
Module c/w 90V Earth Clamp Base
1 Pair (Signal Types, RS485, Profibus-DP, CAN) Protection IS-SL485-EC90
1 Pair (Signal Types , Data Highway) Protection IS-SLDH-EC90
1 Pair (Signal Types, RTD ) Protection IS-SL-RTD-EC90
IEC
Standards Compliance
Ex ia IIC T4 IP20
ITU(CCITT) IX K17
AS1768:2007
BS6651:1999
CP33:1996
IEEE C62.41:2002
IEC 61643-21
UL497B
IS-S
L485
IS-S
LDH
IS-S
L-RT
D
Electrical Specifications
Maximum continuous voltage (DC) UO 7V 34V 7V
Maximum continuous voltage (AC) Uc 5V 24V 5V
Primary GDT rating 8/20us 10kA
Maximum load current IL 500mA 350mA
Signal Type Marshalling Cubicle Field / Remote
RS485 IS-SL485-G IS-SL485-EC90
Profibus DP IS-SL485-G IS-SL485-EC90
CAN IS-SL485-G IS-SL485-EC90
Data Highway IS-SLDH-G IS-SLDH-EC90
RTD applications IS-SL-RTD-G IS-SL-RTD-EC90
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.6. Intrinsically Safe
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.6.3. IS Series Surge Protectors
iS-SSP Series
The IS-SSP6A Hazardous Ares series surge protectors complement the IS-SL range for applications of load currents up to 6A. Typical applications may include power supplies, digital outputs and other low voltage requirements up to 6A. The design of the Novaris IS-SSP6A range include high energy metal oxide varistors. The series connected design eliminates the effect of connection leads inductance encountered with shunt connected surge protectors.
IEC
Description code
Module Only (Without Base)
1 Pair (Signal Types, 12VDC) Protection IS-SSP6A-14
1 Pair (Signal Types , 24VDC) Protection IS-SSP6A-26
1 Pair (Signal Types, 36VDC ) Protection IS-SSP6A-38
Module c/w G Base
1 Pair (Signal Types, 12VDC) Protection IS-SSP6A-14-G
1 Pair (Signal Types , 24VDC) Protection IS-SSP6A-26-G
1 Pair (Signal Types, 36VDC ) Protection IS-SSP6A-38-G
Module c/w 90V Earth Clamp Base
1 Pair (Signal Types, 12VDC) Protection IS-SSP6A-14-EC90
1 Pair (Signal Types , 24VDC) Protection IS-SSP6A-26-EC90
1 Pair (Signal Types, 36VDC ) Protection IS-SSP6A-38-EC90
Accessories
Description code
Base with Ground Connection IS-SLDIN-G
Base with 90V Isolation to Base IS-SLDIN-EC90
order codes
Standards Compliance
Ex ia IIC T4 IP20
ITU(CCITT) IX K17
AS1768:2007
BS6651:1999
CP33:1996
IEEE C62.41:2002
IEC 61643-21
UL497B
IS-S
L485
IS-S
LDH
IS-S
L-RT
D
Electrical Specifications
Maximum continuous voltage (DC) UO 14V 26V 38V
Maximum continuous voltage (AC) Uc 11V 20V 30V
Primary GDT rating 8/20us Imax 9.6kA
Maximum load current IL 6A
Signal Type Marshalling Cubicle Field / Remote
12VDC IS-SSP6A-14-G IS-SSP6A-14-EC90
24VDC IS-SSP6A-26-G IS-SSP6A-26-EC90
36VDC IS-SSP6A-38-G IS-SSP6A-38-EC90
16-729
16.6. Intrinsically Safe
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.6.4. IS Instrument Protectors
IS-SLT1 Intrinsically Safe Instrument Protector
The IS-SLT1 range provides protection for most single twisted pair signalling schemes. The units are shunt connected to the terminals and hence do not interrupt or interfere with the signal. Therefore, the IS-SLT1 range can be adapted to most instruments. Typical applications are analogue and digital instrument transmitters.
IEC
order codes
Description code
20mm Thread Type
One Pair (Signal Type 0-5V Analog, 5V Digital) Protection IS-SLT1-7V5-M20
One Pair (Signal Type 0-10V Analog, 12V Digital) Protection IS-SLT1-18-M20
One Pair (Signal Type 24V Digital) IS-SLT1-36-M20
½” nPt thread type
One Pair (Signal Type 0-5V Analog, 5V Digital) Protection IS-SLT1-7V5-N12
One Pair (Signal Type 0-10V Analog, 12V Digital) Protection IS-SLT1-18-N12
One Pair (Signal Type 24V Digital) IS-SLT1-36-N12
¾” nPt thread type
One Pair (Signal Type 0-5V Analog, 5V Digital) Protection IS-SLT1-7V5-N34
One Pair (Signal Type 0-10V Analog, 12V Digital) Protection IS-SLT1-18-N34
One Pair (Signal Type 24V Digital) IS-SLT1-36-N34
Accessories
Description code
20mm Thread, Y Piece SLT-Y-M20
1/2" NPT Thread, Y Piece SLT-Y-N12
3/4" NPT Thread, Y Piece SLT-Y-N34
Standards Compliance
Ex ia IIC T4 IP20
AS1768:2007
BS6651:1999
CP33:1996
IEEE C62.41:2002
IEC 61643-21
IS-S
LT1-
7V5
IS-S
LT1-
18
IIS-S
LT1-
36
Electrical Specifications
Maximum continuous voltage (DC) UO 7V 16V 34V
Maximum continuous voltage (AC) Uc 5V 11V 24V
Primary GDT rating 8/20us 10kA
Signal Type novaris Product
0-5V analogue IS-SLT1-7V5
0-10V analogue IS-SLT1-18
5V digital IS-SLT1-7V5
12V digital IS-SLT1-18
24V digital IS-SLT1-36
0-20mA analogue IS-SLT1-36
4-20mA analogue IS-SLT1-36
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.6. Intrinsically Safe
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.6.5. IS Load Cell Protectors
iS-LcP intrinsically Safe eX Approved Load cell Protector
The EX Approved IS-LCP provides protection for both 4-wire and 6-wire loadcells as well as the measuring instrument. The LCP is contained within an IP65 enclosure, or alternatively it may be supplied as an assembled PCB. As well as having IS certification the IS-LCP is NSC certified for installation into a loadcell circuit without affecting calibration.
IEC
Description code
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Enclosed 12V System IS-LCP-18
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Non Enclosed 12V System IS-LCP-18-PCB
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Enclosed 24V System IS-LCP-36
Load Cell Protector, with Terminal Strip, 4 & 6 Wire, Non Enclosed 24V System IS-LCP-36-PCB
order codesStandards Compliance
Ex ia IIC T4 IP20
AS1768:2007
BS6651:1999
CP33:1996
IEEE C62.41:2002
IEC 61643-21
NSC No. S366
IS-L
CP-
18
IS-L
CP-
36
IS-L
CP-
18-P
CB
IS-L
CP-
36-P
CB
Electrical Specifications
Maximum continuous voltage (DC) UO 18V 36V 18V 36V
Maximum discharge current 8/20us Imax 250A
Lines protected 4 or 6
16-731
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.7. Special Products16.7.1. Surge Indicator Panel
SIP Surge Indicator Panel
SIP-
110
SIP-
230
Electrical Specifications
Nominal voltage U0 110V / 60Hz 230V / 50Hz
Display LED power and status
Alarm SPDT contacts
Alarm isolation to active circuitry 4kV
Mechanical Specifications
Operating temperature / humidity -40 to +70ºC / 5 to 95%
Connector type 2.5mm2 polarised plug
Terminal screw torque 0.5Nm
Environmental IP 20
Mounting Flush panel mount
Panel cut-out 68mm x 68mm
Weight 200g
Dimensions
Width 72mm
Height 72mm
Depth 55mm
Product Series Nominal voltage
SIP - 230
Novaris Surge Indicator Panel allows remote monitoring of any Novaris product featuring external alarms. Visual and audible indicators provide at-a-glance surge protection status. Designed to fit in standard 72mm panel meter cutouts, integration into switchboards is simple.
order codes
Description code
110VAC Surge Indicator Panel SIP-110
230VAC Surge Indicator Panel SiP-230
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.7. Special Products
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.7.2. EC Earth Clamp
EC Earth Clamp 20kA
Novaris EC provides a means to electrically clamp different earthing systems during transient disturbances. Applications include computer rooms and in the bonding of cable sheaths to ground where direct bonding would introduce interference and “earth loops”.
Electrical Specifications
Active element Gas Discharge Tube (GDT)
DC spark over voltage Uc 90V 230V 350V 600V 1000V
Voltage tolerance ± 20%
Discharge current 8/20µs Imax 20kA
Isolation resistance >1010W
Capacitance <2pF
Mechanical Specifications
Operating temperature / humidity -40 to +70ºC / 5 to 95% non-condensing
Connection type 6mm2 flying leads
Environmental IP 65
Weight 160g
Dimensions
Body diameter 20mm
Body length 60mm
Lead length 500mm each
EC20
-90
EC20
-230
EC20
-350
EC20
-600
EC20
-100
0
Standards Compliance
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC61643
Product Series Uc
Imax
EC 20 - 90
IEC
Description code
Earth Clamp 20kA, 90V EC20-90
Earth Clamp 20kA, 230V EC20-230
Earth Clamp 20kA, 350V EC20-350
Earth Clamp 20kA, 600V EC20-600
Earth Clamp 20kA, 1000V EC20-1000
order codes
16-733
16.7. Special Products
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.7.2. EC Earth Clamp
EC Earth Clamp 100kA
Novaris EC provides a means to electrically clamp different earthing systems during transient disturbances. Applications include computer rooms, defence installations and gas pipeline insulated joints.
Electrical Specifications
Active element Gas Discharge Tube (GDT)
DC spark over voltage Uc 230V 350V 500V 1000V
Voltage tolerance ± 20%
Discharge current 8/20µs Imax 100kA
Isolation resistance >1010W
Capacitance <4pF
Mechanical Specifications
Operating temperature / humidity -40 to +70ºC /5 to 95% non-condensing
Connection type 10mm2 flying leads
Environmental IP 65
Weight 200g
Dimensions
Body diameter 30mm
Body length 100mm
Lead length 500mm each
EC10
0-23
0
EC10
0-35
0
EC10
0-50
0
EC10
0-10
00
Standards Compliance
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
IEC61643 Class 1
EC 100 - 230
Product Series Uc
Imax
IEC
Description code
Earth Clamp 100kA, 230V EC100-230
Earth Clamp 100kA, 350V EC100-350
Earth Clamp 100kA, 500V EC100-500
Earth Clamp 100kA, 1000V EC100-1000
order codes
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.7. Special Products
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.7.3. Cable Bonding Kit
EKIT Cable Bonding Kit
Description code
Cable Bonding Kit Suits 3/8” Heliax EKIT-038
Cable Bonding Kit Suits 1/2” Heliax EKIT-012
Cable Bonding Kit Suits 7/8” Heliax EKIT-078
Cable Bonding Kit Suits 1 5/8” Heliax EKIT-158
Cable Bonding Kit Suits 3 1/8” Heliax EKIT-318
order codes
Electrical Specifications
Connection type Cable clamp
Sheath connection 25mm braid
Earth connection 900mm 6mm2 flying lead
Cable sealing Self amalgamating upper and lower seals
Coaxial cable size 3/8” 1/2” 7/8” 1 5/8” 3 1/8”
EKIT-
038
EKIT-
012
EKIT-
078
EKIT-
158
EKIT-
318
Standards Compliance
AS/NZS 1768
IEEE C62.41
BS 6651
CP 33
Novaris Cable Bonding Kits are used to bond the shields of coaxial feeders and wave guides on communication towers and at cable entry points to communications buildings.
Product Series Cable size
EKIT - 012
16-735
16.7. Special Products
Discount Code C3
Stock Status:Normally stocked /Not normally stocked
For your Information:NSW & VIC only
16
16.7.4. Transient Surge Counter
TSC Transient Surge Counter
Description code
Transient Surge Counter, 100A 98/20uS), IP65 Polycarbonate Enclosure TSC1-IP65
Transient Surge Counter, 100A 98/20uS), DIN Mount External Meter TSC1-DIN
Transient Surge Counter, 100A 98/20uS), DIN Mount External Meter with 100kA Earth Clamp TSC1-DIN-EC
order codes
TSC
1-IP
65
TSC
1-DI
N
TSC
1-DI
N-E
C
Electrical Specifications
Sensitivity 150A
DC spark over voltage Uc - 230V
Discharge current 8/20µs Imax - 150kA
Battery life of counter 7 years
Display Resettable, LCD
Active element - GDT
Voltage tolerance - ± 20%
Isolation resistance - >1010W
Capacitance - <4pF
Mechanical Specifications
Operating temperature / humidity -40 to +70ºC /5 to 95% non-condensing
Terminal capacity - 16mm2
Terminal screw torque - 2.5Nm
Environmental IP 65 IP 20
Mounting Clamp TS35 DIN rail
Counter connection - 2-way plug
Weight 400g 600g
Dimensions
Width 80mm 54mm
Height 110mm 95mm
Depth 65mm 80mm
IEC
Novaris Transient Surge Counters count direct lightning strikes and transient events. They may be clamped to the downconductor of a building or tower or in the earth return conductor of a surge diverter or filter. The EC version also acts as a transient earth clamp.
Product Series Earth ClampType
TSC1 - DIN - EC
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection
For your information:NSW & VIC only
16
16.8. OverviewStandards & SafetyRisk Assessment
Many countries have comprehensive lightning protection standards. As a global provider of lightning and surge protection solutions Novaris strives to provide its solutions in accordance with recognised world standards.
As an Australian company Novaris conforms strictly to the guidelines contained in the Australian and New Zealand standard on lightning protection AS/NZS1768:2007.
Additionally Novaris’ solutions and products conform to the relevant IEC standards, notably IEC62305 (Protection against Lightning) and IEC61643 (Low-voltage Surge Protection Devices).
In line with AS/NZS1768:2007, Novaris does not recommend or endorse the use of so called non-conventional lightning ‘attraction’ or protection systems.
Because Novaris cares about personnel and equipment safety all our products are subjected to rigorous testing in our laboratory. We are able to generate most of the test waveforms specified in the IEC, Australian and US standards. We can test for temporary overvoltage and high current test series connected or two port SPDs up to 2000A per phase.
Because of the unpredictable nature of lightning transients and the follow on effects of power systems overvoltages, surge protection components can be overloaded and fail catastrophically. For this reason our laboratory is equipped to carry out the most severe of destructive tests.
From years of experience we know that surge protection components can rupture and be subject to excessive heating under fault conditions. It is for this reason that all Novaris power line surge protection products are housed in robust metal enclosures and we recommend that all SPDs be protected with appropriate fuses or circuit breakers in accordance with the relevant standards.
Standards
Safety
Risk AssessmentHistorically, lightning protection consulting only concentrated on the protection of buildings and structures. Little thought was ever given to protecting against the indirect effects of lightning strikes which causes damage to equipment, regardless of whether structural protection is present or not. It was simply assumed that structural lightning protection would protect everything.
This is far from being the case, and protection against the indirect effects of a lightning strike is often more important that structural protection.
When it is considered that many modern buildings with steel frames and metal sheet roofing are inherently self protecting, it is regrettable to see structural lightning protection added for absolutely no reason, particularly when the indirect protection has been completely ignored.
Fortunately this situation is now recognised and both the IEC and the Australian and New Zealand lightning protection standards present risk assessment procedures capable of clearly defining the need for both structural and surge (or indirect) protection. The IEC standard (IEC62305-2) recognizes the need for both structural and surge protection but mandates that structural protection is necessary whenever surge protection is needed (Figure 1). The Australian and New Zealand standard (AS/NZS1768:2007) allows surge protection in the absence of structural protection (Figure 2). This is entirely rational.
Any lightning protection design should first start with a risk assessment. If structural protection is required,first determine if the structure is self protecting before following the procedures in the standards.
Figure 1. IEC Risk Assessment Procedure (from IEC62305-2) Figure 2. Australian and New Zealand Standard
Risk Assessment Procedure (from AS/NZS1768:2007)
16-737
16.8. OverviewFor your Information:NSW & VIC only
16
Surge Ratings
The ratings of primary and secondary surge protection can be obtained from the Australian Standard.AS/NZS1768:2007 makes specific recommendations for the surge ratings of surge protection devices.Figure 3 is taken from this standard.
The above table recommends that for main switchboards at sites fitted with a lightning protection system, or fed with long overhead power lines, the surge rating of primary LV arresters (per phase) should be at least 100kA for an 8/20µs impulse.
All SPDs should be installed in accordance with AS4070, or the equivalent wiring standard for that country, and be connected between each phase and neutral. At switchboards where there is no MEN, neutral-earth protection is also required. The neutral-earth protection is generally provided by means of a high energy gas discharge tube (GDT), with Imax = 100kA.
RECOMMENDED SURGE RATINGS FOR A.C. POWER SYSTEMSPDs Per PhASe
Category SPD location Imax ratings
A Long final subcircuits and electricity supply outlets 3-10kA
B Major submains, short final subcircuits and load centres 10-40kA
C1 Service entrance, other than below 40kA
C2 Service entrance, building fed by long overhead service lines, or is a large industrial or commercial premises
40-100kA
C3 Service entrance, building in a high lightning area, or fitted with a LPS 100kA Figure 3. Table 5.1 from AS/NZS1768:2007
Secondary protection generally requires a lower surge rating. Sub-boards within buildings can be regarded as occupying location category B and surge ratings around 40kA are suitable. The most appropriate surge protector for these applications is a series connected device, either a series surge protector or surge filter. These will require all mode protection since there is unlikely to be an MEN link in the equipment cabinet.
The normal configuration of primary and secondary protection would be shunt surge diverters as the primary protection and suitably rated series protection devices as secondary protection in the sub or distribution boards.
At sites where primary and secondary protection is required, yet the cable length from MSB to equipment is short (typically less than 10m), a surge filter protecting the whole site should be considered. This would have the appropriate category C surge rating plus an LC filter and a final stage of category B surge protection. The series inductance “builds out” (artificially lengthens) the line. The above is appropriate for small sites such as cellular basestations, TV translators, remote telemetry field sites etc.
At installations with an MSB and a number of distribution boards, such as a multi-storey building, primary and secondary protection should be provided. The primary protection would comprise shunt connected surge diverters fitted to the main switchboard. These provide a path to earth, via the neutral, for the surge energy.
Note: These SPDs are wired from phase to neutral in accordance with the IEC and other standards. In countries employing the MEN system the MEN link provides the neutral to earth path. In other countries the neutral to earth connection may be via a high energy gas discharge tube (GDT).
The effectiveness of this primary protection depends upon how it is installed. In large switchboards long shunt leads are unavoidable and the voltage let through by such primary protection is unlikely to be low enough to provide effective protection for sensitive loads. It is generally sufficient to protect the switchboard.For this reason secondary protection is recommended.
Surge filters provide the best protection and are recommended to protect electronic and computing equipment. Being series connected these eliminate the degradation caused by long shunt connected leads; and with an inbuilt low pass LC filter their let through voltage (Up), is low enough to protect the most sensitive electronic equipment.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
16. Lightning & Surge Protection16.8. Overview
For your Information:NSW & VIC only
16
Installation
Effective surge protection is highly dependant upon installation practices. All Novaris products are supplied with detailed installation instructions to ensure they are installed correctly. The following diagrams show examples of power line surge diverter and surge filter installations.
Install protection:- Downstream of the main switch.- Upstream of all equipment including earth leakage devices where possible.- Protect with 63A HRC fuses or circuit breaker.- Keep lead lengths as short as possible.
MEN systems - install single mode (L-N) protection as close to the MEN link as possible.Non-MEN systems - install all mode (L-N, L-PE, N-PE) protection.
Install all mode protection:- Downstream of main switch.- Upstream of all equipment, including earth leakage devices where possible.- Protect with HRC fuses or circuit breaker, with current rating less than or equal to the load current rating of the filter.- Keep output cables away from input cables.
Install all mode protection:- Downstream of main switch.- Upstream of all equipment, including earth leakage devices where possible.- Protect with 32A HRC fuses or circuit breakers.- Keep lead lengths as short as possible.
Install all mode protection:- Downstream of fuses or circuit breaker with current rating less than or equal to the load current rating of the filter.- As close to the equipment as possible.- Keep output cables away from input cables.
For further details see individual product installation instructions.
Surge Diverter – Main Switchboard
Surge Filter – Distribution Board
Surge Diverter – Distribution Board
Surge Filter – Final Circuit / Equipment
16-739
16.8. OverviewFor your Information:NSW & VIC only
16
Installation
1. Provide adequate protection for all equipment.2. Achieve a long working life.3. Allow the signal to pass under normal operation and not have an adverse affect on insertion loss and return loss.4. Optimise the cost and size of the surge protection devices (SPDs).
Novaris manufacturers two types of RF coaxial SPDs. Those containing a gas discharge tube (GDT) are suitable for a wide frequency range but must be chosen carefully taking into account the power on the line if used for a transmitting application. Quarter wave stub protectors offer exceptionally low let through voltages but are frequency sensitive. Their power handling capability is only limited by the rating of the coaxial connectors employed.
1. identify the connector type
Novaris manufactures a range of coaxial SPDs to suit most common connectors and gender variations.
2. Select the clamping voltage
The clamping voltage of the SPD must be greater than the peak voltage on the line. This is particularly important when used for transmitting applications. The following is a guide.
3. Identify the maximum operating frequency
For standard models using N-type connectors the maximum frequency is 2GHz. 3G models feature replaceable GDTs and will operate to 3GHz. For other variations the upper frequency is dependent upon the connector type.
4. tuned stub protectors
For narrow bandwidth applications where no DC voltage is injected, tuned stub protectors provide exceptionally low let through voltages and very low intermodulation products. The centre operating frequency must be specified when ordering.
Power in 50W (W) GDT Voltage (V)
0-40 90
40-125 230
125-300 350
300-800 600
800-2000 1000
Coaxial line surge protection must:
Options for Surge Protection Devices
Selection of Surge Protection Devices
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17.1.1. MicroSection Guide Overview
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17.1.1.1. XXX
17
17. TerminaTion & Wiring SySTemS
SecTion 17
17-741
17
TerminaTion & Wiring SySTemS
17. TerminaTion & Wiring SySTemS 17-74017.1. Screw connection Terminals 17-742
Overview 17-74217.1.1. Standard Feed Through Terminals 17-74317.1.2. High Current Terminals 17-74517.1.3. Bolt Connection Terminals 17-74617.1.4. Double-Deck Terminals 17-74717.1.5. Multilevel Terminals 17-74817.1.6. Sensor Terminals 17-74917.1.7. Disconnect Terminals 17-75017.1.8. Test & Disconnect Terminals 17-75117.1.9. Fuse Terminals 17-752
17.2. Spring clamp Terminals 17-753Overview 17-75317.2.1. Standard Feed Through Terminals 17-75417.2.2. Double-Deck & Multilevel Terminals 17-75617.2.3. Sensor Terminals 17-75717.2.4. Disconnect Terminals 17-75817.2.5. Fuse & Disconnect Terminals 17-75917.2.6. Multi Input/Output Terminals 17-760
17.3. Warning Labels 17-76117.4. markers 17-76117.5. Din-rail 17-76217.6. Wiring Duct 17-76217.7. Typical Specifications 17-763
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS
17
17.1. Screw Connection TerminalsOverview
Screw clamp Terminal Blocks
This is the most popular of all known methods of connection. Screw connection refers to any connection in which the conductor is stripped of its insulation and clamped without any special preparation. Klemsan screw clamp system is built in protection against loosening.
When the screw is tightened, the resultant pressure pulls apart both halves of the clamping yoke. This generates a particularly high locking action on the screw. These clamping systems provide excellent vibration resistance.
17-743
17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.1. Standard Feed Through Terminals
order codes - Terminals
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 2.5mm 24A/750V~ 44.2 5 44.5 100 AVK 2.5 GREY 304 120
4mm 32A/750V~ 44.2 6 44.5 100 AVK 4 GREY 304 130
6mm 41A/630V~ 44.2 8 44.5 100 AVK 6 GREY 304 140
10mm 57A/630V~ 44.2 10 44.5 100 AVK 10 GREY 304 150
16mm 76A/750V~ 50 12 55.5 50 AVK 16 GREY 304 160
35mm 125A/750V~ 52,8 16 58.7 40 AVK 35 GREY 304 250
Blue 2.5mm 24A/750V~ 44.2 5 44.5 100 AVK 2.5 BLUE 304 121
4mm 32A/750V~ 44.2 6 44.5 100 AVK 4 BLUE 304 131
6mm 41A/630V~ 44.2 8 44.5 100 AVK 6 BLUE 304 141
10mm 57A/630V~ 44.2 10 44.5 100 AVK 10 BLUE 304 151
16mm 76A/750V~ 50 12 55.5 50 AVK 16 BLUE 304 161
35mm 125A/750V~ 52,8 16 58.7 40 AVK 35 BLUE 304 251
Earth 4mm - 42 6 44.5 50 AVK 2.5/4T YELLOW-GREEN 334 120
10mm - 42 10 44.5 25 AVK 6/10T YELLOW-GREEN 334 140
16mm - 52.8 12 58.7 50 AVK 16TRD YELLOW-GREEN 334 200
35mm - 52.8 16 58.7 40 AVK 35TRD YELLOW-GREEN 334 210
50mm - 80 20 81.8 10 AVK 50T YELLOW-GREEN 334 190
aVK Series
aVK Series Terminals
aVK 2.5 grey
aVK 2.5/4T yellow-green
aVK 16 grey
AVK Series Screw Connection Rail Terminals provide the whole range of cross sections from 2,5 up to 240 mm2. Terminals accessories like Cross Connection, End Plate, Comb Connector are available.
The strict IEC requirement imposed on ground connections, such as low contact resistance, corrosion-free connection points, secured screws are fully observed by the KLEMSAN Earth terminal blocks, which are available with cross sections 2,5 mm2 ..... 50 mm2.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.1. Standard Feed Through Terminals
order codes - end covers
order codes - Partitions
order codes - end Stops
order codes - cross connectors
Type Terminal Size Box Qty Description codeGrey 2.5mm 100 NPP 2.5-10 GREY 444 120
4mm6mm10mm16mm 100 NPP 16 GREY 444 16035mm - - -
Type Terminal Size Box Qty Description codeGrey 2.5mm 100 APP 2.5-10 GREY 462 120
4mm6mm10mm16mm 100 APP 16 GREY 462 16035mm 25 APP/AVK 35 RD GREY 462 180
Type Description Box Qty Type codeGrey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059Mid duty with screw 50 KD7 GREY 495 219
Suit Terminal Size number of Poles Box Qty Description code2.5mm 2 25 UK 2.5/2-AVK 2.5 474 122
3 20 UK 2.5/3 2-AVK 2.5 474 12310 5 UK 2.5/10 2-AVK 2.5 474 129
4mm 2 25 UK 4/2-AVK 4 474 1323 20 UK 4/3-AVK 4 474 13310 5 UK 4/10-AVK 4 474 139
6mm 2 25 UK 6/2-AVK 6 474 1423 20 UK 6/3-AVK 6 474 14310 5 UK 6/10-AVK 6 474 149
10mm 2 25 UK 10/2-AVK 10 474 1523 20 UK 10/3-AVK 10 474 15310 5 UK 10/10-AVK 10 474 159
16mm 2 25 UK 16/2-AVK 16 474 1623 20 UK 16/3-AVK 16 474 16310 5 UK 16/10-AVK 16 474 169
35mm 2 25 UK 35/2-AVK 35 474 1723 20 UK 35/3-AVK 35 474 17310 5 UK 35/10-AVK 35 474 179
nPP 2.5-10 grey
aPP 2.5-10 grey
KD3 KD4
KD7
order codes - comb connectors
Suit Terminal Size number of Poles Box Qty Description code2.5mm 2 25 TKO 2.5/2-AVK 2.5 476 262
3 20 TKO 2.5/3-AVK 2.5 476 26310 5 TKO 2.5/10-AVK 2.5 476 269
4mm 2 25 TKO 4/2-AVK 4 476 2723 20 TKO 4/3-AVK 4 476 27310 5 TKO 4/10-AVK 4 476 279
6mm 2 25 TKO 6/2-AVK 6 476 2823 20 TKO 6/3-AVK 6 476 28310 5 TKO 6/10-AVK 6 476 289
10mm 2 25 TKO 10/2-AVK 10 476 2923 20 TKO 10/3-AVK 10 476 29310 5 TKO 10/10-AVK 10 476 299
17-745
17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
order codes - Terminals
aVK Series
High current / Bolt connection Terminals
aVK50 grey
aVK240 grey
AVK Series Screw Connection High Current Terminals provide 50 ..... 240 mm2 cross- section range. Cross Connection can be used for terminals with all cross-sections. These terminal blocks are fixed to each other via pins on sides, providing a rigid performance on DIN Rail and easy montage advantages in constricted environments where connection with Insulated Terminals are difficult. EK-6 terminals are used for taking additional cable (for signals etc.) from high current (big cross sectioned) terminal blocks.
AVK Busbar Type High Current Terminals provides 95 ..... 240 mm2 cross-section range, when cable connection is done by insulated terminals connected to the Types of the conductor. Isolation cover is designed for insulated terminals having different dimensions. Cross Connection can be used for terminals with all cross-sections. A fixing screw is available in order to maintain a more secure mounting on the DIN rail.
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 50mm 150A/1000V~ 80 20 84.7 25 AVK50 GREY 304 330
70mm 192A/1000V~ 80 22 88.7 10 AVK70 RD GREY 304 490
95mm 232A/1000V~ 80 25 94.5 6 AVK95 GREY 304 340
150mm 309A/1000V~ 93 31 111.75 4 AVK150 GREY 304 350
240mm 415A/1000V~ 93 36 127 4 AVK240 GREY 304 360
order codes - cross connectors
order codes - end Stops
order codes - additional Signal cable connectors
Suit Terminal Size number of Poles Box Qty Description code
50mm 2 5 UK 50/2-AVK50 478 332
3 5 UK 50/3-AVK50 478 333
4 5 UK 50/4-AVK50 478 334
70mm 2 5 UK 70/2-AVK70 478 372
3 5 UK 70/3-AVK70 478 373
4 5 UK 70/4-AVK70 478 374
95mm 2 5 UK 95/2-AVK95 478 342
3 5 UK 95/3-AVK95 478 343
4 5 UK 95/4-AVK95 478 344
150mm 2 5 UK 150/2-AVK150 478 352
3 5 UK 150/3-AVK150 478 353
4 5 UK 150/4-AVK150 478 354
240mm 2 5 UK 240/2-AVK240 478 362
3 5 UK 240/3-AVK240 478 363
4 5 UK 240/4-AVK240 478 364
Type Description Box Qty Type code
Grey Heavy duty with screw 50 KD6 GREY 495 099
Suit Terminal Size Box Qty Description code
95mm 20 AVK/EK6 304 370
150mm
240mm
17.1.2. High Current Terminals
UK 50/2
UK 95/2
UK 150/2
aVK/eK6
KD6
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.3. Bolt Connection Terminals
aVK95B grey
aVK240B greyorder codes - cross connectors
order codes - isolation cover
Suit Terminal Size number of Poles Box Qty Description code
95mm 2 5 UKB 95/2-AVK95B 478 302
3 5 UKB 95/3-AVK95B 478 303
4 5 UKB 95/4-AVK95B 478 304
150mm 2 5 UKB 150/2-AVK150B 478 312
3 5 UKB 150/3-AVK150B 478 313
4 5 UKB 150/4-AVK150B 478 314
240mm 2 5 UKB 240/2-AVK240B 478 322
3 5 UKB 240/3-AVK240B 478 323
4 5 UKB 240/4-AVK240B 478 324
Suit Terminal Size Box Qty Description code
95mm 4 KKB 95 GREY 466 100
150mm 4 KKB 150 GREY 466 110
240mm 4 KKB 240 GREY 466 120
order codes - Terminals
aVK Series
Type Size ratings Dimensions Box Qty Description code
L W H
Grey 95mm 232A/1000V~ 90 40 54 4 AVK95B GREY 304 300
150mm 309A/1000V~ 108 48 54 4 AVK150B GREY 304 310
240mm 415A/1000V~ 122 53 54 4 AVK240B GREY 304 320
UKB 95/2
UKB 150/2
UKB 240/2
17-747
17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.4. Double-Deck Terminals
order codes - cross connectors
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-AVK 2.5 474 122
3 20 UK 2.5/3 2-AVK 2.5 474 123
10 5 UK 2.5/10 2-AVK 2.5 474 129
4mm 2 25 UK 4/2-AVK 4 474 132
3 20 UK 4/3-AVK 4 474 133
10 5 UK 4/10-AVK 4 474 139
10mm 2 25 UK 10/2-AVK 10 474 152
3 20 UK 10/3-AVK 10 474 153
10 5 UK 10/10-AVK 10 474 159
Screw Type multilevel / Sensor Terminals
PUK Series Screw Connection Sensor Terminals are making sensor connections, which are often used in industry, more practical and esthetic. Provide individual cross connections for each layer, time saving in mounting process. Can be used with NPN and PNP types of sensors.
PIK Series Screw Connection Double-Deck Rail Terminals provide 2,5 - 4 - 10 mm2 cross-section range. Double wiring density available without extension of mounting rails. Interconnection / shorting can be done at both layers.
Double Deck Earth Terminals can be used in panels with limited space. Multipole connection on a single block and cross connection on both levels provide practical Earth connection.
PUK Series Screw Connection Multilevel terminals provides solutions for different users’ needs. They are ideal for limited spaces with their compact designs. In panels which exist switch lines & lighting, provide phase-neutral-Earth connection in one terminal. PUK Series are ideal for usage in industries where motors are working a lot, with practical wiring. Cross connection can be used on each level.
order codes - Terminals
PiK Series
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 2.5mm 24A/500V~ 64 5 61.3 100 PIK 2.5N GREY 317 109
4mm 32A/500V~ 64 6 61.3 100 PIK 4N GREY 319 109
10mm 57A/800V~ 77.9 10 73 20 PIK 10N GREY 319 909
Blue 2.5mm 24A/500V~ 64 5 61.3 100 PIK 2.5N BLUE 317 101
4mm 32A/500V~ 64 6 61.3 100 PIK 4N BLUE 319 101
Earth 2.5mm - 64 5 61.3 100 PIK 2.5NT YELLOW-GREEN 336 560
4mm - 64 6 61.3 100 PIK 4NT YELLOW-GREEN 336 570
order codes - end covers
Type Terminal Size Box Qty Description code
Grey 2.5mm4mm
25 NPP PIK2.5-4N GREY 449 019
10mm 20 NPP PIK10N GREY 449 039
Earth 2.5mm4mm
25 NPP PIK2.5-4N YELLOW-GREEN 449 012T
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Heavy duty with screw 50 KD6 GREY 495 099
KD4
PiK 2.5n
PiK 4nT
KD7
KD6
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.5. Multilevel Terminals
order codes - cross connectors
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-PUK3 480 132
3 20 UK 2.5/3 2-PUK3 480 133
10 5 UK 2.5/10 2-PUK3 480 139
order codes - Terminals
PUK Series
Configuration Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Feed-Through Grey 2.5mm 24A/440V~ 87.15 6 65.2 20 PUK3 GREY 324 109
2 Pole & Earth Grey 2.5mm 24A/440V~ 87.15 6 65.2 20 PUK2T GREY 324 209
3 Pole & Earth Grey 2.5mm 24A/440V~ 87.15 6 65.2 20 PUK3T GREY 324 309
order codes - end covers
Type To Suit Box Qty Description code
Grey PUK3 10 NPP PUK3 GREY 450 139
PUK2T 10 NPP PUK2T GREY 450 149
PUK3T 10 NPP PUK3T GREY 450 159
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Heavy duty with screw 50 KD6 GREY 495 099
PUK3 grey
PUK 2T grey
PUK 3T grey
nPP PUK 3
KD4
KD7
KD6
17-749
17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.6. Sensor Terminals
order codes - cross connectors
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-PUK3 480 132
3 20 UK 2.5/3 2-PUK3 480 133
10 5 UK 2.5/10 2-PUK3 480 139
order codes - Terminals
Configuration Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Standard Grey 2.5mm 24A/500V~ 74.3 6 65.2 20 PUK3S GREY 324 409
NPN Grey 2.5mm 24A/-V~ 74.3 6 65.2 20 PUK3 SLD NPN GREY
324 419
PNP Grey 2.5mm 24A/-V~ 74.3 6 65.2 20 PUK3 SLD PNP GREY
324 309
order codes - end covers
Type To Suit Box Qty Description code
Grey PUK3S PUK3 SLD 10 NPP PUK 3S GREY 450 169
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Heavy duty with screw 50 KD6 GREY 495 099
PUK Series
PUK3S grey
PUK 3SLD nPn grey
PUK 3SLD PnP grey
KD4
KD7
KD6
nPP PUK 3 S
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.7. Disconnect Terminals
order codes - cross connectors
order codes - Blade Type Terminals
order codes - Screw Type Terminals
aSK & aVK Series
Screw connection Disconnect / Test and Disconnect / Fuse Terminals
order codes - end covers
Type To Suit Box Qty Description code
Grey 2.5mm 25 NPP AVK 2.5 CC GREY 444 139
4mm 10 NPP ASK 3 GREY 450 059
6mm 25 NPP ASK 2 GREY 450 049
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 459 219
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 2.5mm 16A/400V~ 57.1 6 50.1 80 AVK 2.5 EA GREY 324 949
4mm 16A/500V~ 60 6.2 50.5 50 ASK 3 A GREY 353 109
6mm 6.3A/500V~ 60 8 45 25 ASK 2 B GREY 360 119
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 4mm 16A/500V~ 53.5 6.2 72.5 20 ASK 3 MB GREY 363 009
6mm 6.3A/750V~ 74.4 10 51.4 20 ASK 4 B GREY 360 129
Knife Disconnect System, enables Screw Connection Disconnect Terminals to switch energy in the system.
Screw Connection Fuse Rail Terminals can be used with glass fuse between 1A...10A. The fuse inside of the terminal is easily mounted and dismounted, and is an ideal solution when there is a necessity to change it even when the power is on in the system.
Test and Disconnect Terminals provide safe connection with spring force under the contact of the terminal block. Practical accessories like sliding cross connection system, isolated Test Sockets, Test Plugs and Comb Connectors are available.
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-AVK 2.5 474 122
3 20 UK 2.5/3 2-AVK 2.5 474 123
10 5 UK 2.5/10 2-AVK 2.5 474 129
4mm 2 25 UK 4/2-AVK 4 474 132
3 20 UK 4/3-AVK 4 474 133
10 5 UK 4/10-AVK 4 474 139
6mm 2 25 UK 6/2-AVK 6 474 142
3 20 UK 6/3-AVK 6 474 143
10 5 UK 6/10-AVK 6 474 149
aSK 2B grey
aSK 3a grey
aSK 3mB
aSK 4B
nPP aSK 3
KD3 KD4
KD7
17-751
17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.8. Test & Disconnect Terminals
order codes - cross connectors
order codes - comb connectors
order codes - Terminals
Wgo Series
accessories
order codes - end covers
Type Description code
Disconnect Tool WGO UAA 498 300
Type To Suit Box Qty Description code
Grey 6mm 25 NPP WGO 3 GREY 450 229
10mm 25 NPP WGO 2N GREY 450 239
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 6mm 41A/400V~ 65 8 49.5 50 WGO 3 GREY DOUBLE SOCKET
375 692
10mm 57A/400V~ 74.6 10 51.7 50 WGO 2N GREY DOUBLE SOCKET
375 892
Suit Terminal Size number of Poles Box Qty Description code
6mm 2 10 IZUK 6/2 476 302
3 10 IZUK 6/3 476 303
4 10 IZUK 6/4 476 304
10 5 IZUK 6/10 476 309
10mm 2 10 IZUK 10/2 476 402
3 10 IZUK 10/3 476 403
4 10 IZUK 10/4 476 404
10 5 IZUK 10/10 476 409
Suit Terminal Size number of Poles Box Qty Description code
6mm 2 25 TKO 6/2 476 282
3 20 TKO 6/3 476 283
4 15 TKO 6/4 476 284
10 5 TKO 6/10 476 289
10mm 2 25 TKO 10/2 476 292
3 20 TKO 10/3 476 293
4 15 TKO 10/4 476 294
10 5 TKO 10/10 476 299
Wgo 2n grey
Wgo 3 grey
KD3 KD4
KD7
iZUK
Wgo - Uaa
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.1. Screw Connection Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.1.9. Fuse Terminals
order codes - Push-in cross connectors
order codes - Terminals
aSK Series
order codes - end covers
Type To Suit Box Qty Description code
Grey 4mm 10 NPP ASK 3 GREY 450 059
6mm 25 NPP ASK 2 GREY 450 049
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
grey 4mm 10A/500V~ 53.5 6.2 65 50 ASK 3F GREY 354 109
6mm 6.3A/500V~ 60 8 45 30 ASK 2S GREY 351 109
Suit Terminal Size number of Poles Box Qty Description code
4mm 2 25 UK 4/2-YBK 4/ASK 3 476 232
3 20 UK 4/3-YBK 4/ASK 3 476 233
4 15 UK 4/4-YBK 4/ASK 3 476 234
aSK 2S grey
aSK 3F grey
KD3 KD4
KD7
nPP aSK 3
nPP aSK 2
17-753
17
17.2. Spring Clamp TerminalsOverview
Spring clamp Terminal Blocks
Catch the technology with PYK series terminal blocks. PYK is the newest technology in the spring clamp connection type; it provides users with fast and secure connection. Cable is connected to the terminal just by pushing-in, without the need to use a screwdriver. PYK is suitable for applications with or without ferrules. All you need to do is to push the cable into the cable hole to make the connection. If needed, cable can be released easily by using a screwdriver.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.1. Standard Feed Through Terminals
order codes - Terminals
PyK Series
PyK Series Terminals
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Grey 1.5mm 17.5A/800V~ 53.3 4.2 43 80 PYK 1.5 GREY 307 009
2.5mm 24A/800V~ 53.3 5 43 100 PYK 2.5 GREY 307 109
4mm 32A/800V~ 55.9 6 44 100 PYK 4 GREY 307 119
6mm 41A/800V~ 65.6 8 46.2 60 PYK 6 GREY 307 129
10mm 57A/800V~ 75.4 10 52.2 50 PYK 10 GREY 307 139
Blue 1.5mm 17.5A/800V~ 53.3 4.2 43 80 PYK 1.5 BLUE 307 001
2.5mm 24A/800V~ 53.3 5 43 100 PYK 2.5 BLUE 307 101
4mm 32A/800V~ 55.9 6 44 100 PYK 4 BLUE 307 111
6mm 41A/800V~ 65.6 8 46.2 60 PYK 6 BLUE 307 121
10mm 57A/800V~ 75.4 10 52.2 50 PYK 10 BLUE 307 131
Earth 1.5mm - 53.3 4.2 43 80 PYK 1.5 T YELLOW-GREEN 336 490
2.5mm - 53.3 5 43 50 PYK 2.5 T YELLOW-GREEN 336 500
4mm - 55.9 6 44 50 PYK 4 T YELLOW-GREEN 336 510
6mm - 65.6 8 46.2 60 PYK 6 T YELLOW-GREEN 336 520
10mm - 75.4 10 52 25 PYK 10 T YELLOW-GREEN 336 530
PYK Series Practical Spring Clamp Terminals provide 1,5 ..... 10 mm2 cross-section range. Screwdriver is not necessary to install wire into the terminal block. Are suitable for usage with or without ferrules.
PYK Series Earth Terminals provides 1,5 ..... 10 mm2 cross-section range. Screwdriver is not necessary to mount the terminal block on the rail. Mounting is more time-saving and practical. Yellow- Green color of the insulation body provides easy identification out of other Terminals.
PyK 1.5 grey
PyK 1.5T yellow-green
PyK 10 grey
PyK 10T yellow-green
17-755
17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.1. Standard Feed Through Terminals
order codes - Push-in cross connectors
order codes - end covers
order codes - Partitions
Type To Suit Box Qty Description code
Grey 1.5mm 2.5mm
100 NPP PYK 2.5 GREY 446 449
4mm 100 NPP PYK 4 GREY 446 459
6mm 50 NPP PYK 6 GREY 446 469
10mm 50 NPP PYK 10 GREY 446 479
Earth 1.5mm 2.5mm
100 NPP PYK 1.5-2.5 T YELLOW-GREEN
446 442 T
4mm 10 NPP PYK 4 T YELLOW-GREEN 446 452 T
6mm 10 NPP PYK 6 T YELLOW-GREEN 446 462 T
10mm 10 NPP PYK 10 T YELLOW-GREEN 446 472 T
Type To Suit Box Qty Description code
Grey 1.5mm2.5mm4mm
25 APP PYK 1.5 GREY 463 180
6mm 25 APP PYK 6 GREY 463 190
10mm 25 APP PYK 10 GREY 463 200
Suit Terminal Size number of Poles Box Qty Description code
1.5mm 2 25 UK 1.5/2-PYK 1.5 476 602
3 20 UK 1.5/3-PYK 1.5 476 603
10 5 UK 1.5/10-PYK 1.5 476 609
2.5mm 2 25 UK 2.5/2-PYK 2.5 476 222
3 20 UK 2.5/3-PYK 2.5 476 223
10 5 UK 2.5/10-PYK 2.5 476 229
4mm 2 25 UK 4/2-PYK 4 476 232
3 20 UK 4/3-PYK 4 476 233
10 5 UK 4/10-PYK 4 476 239
6mm 2 25 UK 6/2-PYK 6 476 242
3 20 UK 6/3-PYK 6 476 243
10 5 UK 6/10-PYK 6 476 249
10mm 2 25 UK 10/2-PYK 10 476 252
3 20 UK 10/3-PYK 10 476 253
10 5 UK 10/10-PYK 10 476 259
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
KD3 KD4
KD7
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.2. Double-Deck & Multilevel Terminals
PyK Series Sensor
Double Deck Practical Spring Terminals are available in 2,5 - 4 mm cross section range. Double wiring density available without extension of mounting rails. Interconnection / shorting can be done at both layers.
Multilevel Practical Spring Terminals make wiring more practical, reduce the installation costs and speed the wiring. Panels which exist switch lines & lightening, provide phase-neutral-Earth connection in one terminal.
Practical Spring Terminals are making sensor connections, which are often used in industry, more practical and esthetic. Can be used with NPN and PNP types of sensors.
order codes - Push-in cross connectors
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-YBK 2.5 476 222
3 20 UK 2.5/2-YBK 2.5 476 223
10 5 UK 2.5/2-YBK 2.5 476 229
order codes - Terminals
PyK Series
Configuration Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Feed-Through Grey 2.5mm 24A/500V~ 75.3 5 62.9 40 PYK 2.5-2F GREY 307 179
Feed-Through Grey 2.5mm 24A/500V~ 98.7 5 83.1 30 PYK 2.5-3F GREY 307 199
3 Pole & Earth Grey 2.5mm 24A/500V~ 117.1 5 93 30 PYK 2.5-3FT GREY 307 209
order codes - end covers
Type To Suit Box Qty Description code
Grey PYK 2.5-2F 25 NPP PYK 2.5-2F GREY 446 519
PYK 2.5-3F 10 NPP PYK 2.5-3F GREY 446 529
PYK 2.5-3FT 30 NPP PYK 2.5-3FT GREY 446 539
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Heavy duty with screw 50 KD6 GREY 495 099
PyK 2.5-2F grey
PyK 2.5-3F grey
PyK 2.5-3FT grey
KD4
KD7
KD6
17-757
17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.3. Sensor Terminals
PyK Series
order codes - Push-in cross connectors
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-YBK 2.5 476 222
3 20 UK 2.5/3 2-YBK 2.5 476 223
10 5 UK 2.5/10 2-YBK 2.5 476 229
order codes - Terminals
Configuration Type Size ratings Dimensions (mm) Box Qty Description code
L W D
Standard Grey 2.5mm 24A/250V~ 79.4 5 56.7 20 PYK3S GREY 307 409
NPN Grey 2.5mm 24A/-V~ 79.4 5 56.7 20 PYK3S SLD NPN GREY
307 419
PNP Grey 2.5mm 24A/-V~ 79.4 5 56.7 20 PYK3S SLD PNP GREY
307 429
order codes - end covers
Type To Suit Box Qty Description code
Grey PYK3S PYK3 SLD 10 NPP PYK 3S GREY 446 609
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Heavy duty with screw 50 KD6 GREY 495 099
PyK3S grey
PyK3S SLD nPn grey
PyK3S SLD PnP grey
KD4
KD7
KD6
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.4. Disconnect Terminals
order codes - Push-in cross connectors
order codes - Terminals
Disconnect Terminals
PyK Series
order codes - end covers
Type To Suit Box Qty Description code
Grey 2.5mm 100 NPP PYK 2.5A 446 509
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
grey 2.5mm 20A/400V~ 70.8 5 43.7 50 PYK 2.5A 307 169
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-YBK 2.5 476 222
3 20 UK 2.5/3 2-YBK 2.5 476 223
10 5 UK 2.5/10 2-YBK 2.5 476 229
Disconnect Terminals enables to safely open- close the circuit , when the energy is on in the system.
Practical Spring Clamp Fuse Terminals has a sliding type hinged carrier that has a specially designed space for catridge type glass fuse of size Ø 5x20 or Ø 5x25 together with a spare one.
PyK 2.5a grey
KD3 KD4
KD7
17-759
17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.5. Fuse & Disconnect Terminals
order codes - Push-in cross connectors
order codes - Terminals
PyK Series
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty with screw 100 KD3 GREY 495 049
Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Type Size ratings Dimensions (mm) Box Qty Description code
L W D
grey 4mm 10A/500V~ 63.1 8 61.1 15 PYK 4S 307 249
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 6/2-YBK 6 476 242
3 20 UK 6/3 2-YBK 6 476 243
10 5 UK 6/10 2-YBK 6 476 249
PyK 4S grey
KD3 KD4
KD7
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS17.2. Spring Clamp Terminals
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.2.6. Multi Input/Output Terminals
order codes - Push-in cross connectors
order codes - Terminals
PyK Series multi input/output Terminals
PyK Series
order codes - end covers
Type To Suit Box Qty Description code
Grey PYK 2.5 E GREY 10 NPP PYK 2.5 E GREY 446 619
PYK 2.5 C GREY 10 NPP PYK 2.5 C GREY 446 499
PYK 4 E GREY 10 NPP PYK 4 E GREY 446 559
Earth PYK 2.5 ET YELLOW-GREEN 10 NPP PYK 2.5 ET YELLOW-GREEN 446 612T
PYK 2.5 CT YELLOW-GREEN 10 NPP PYK 2.5 CT YELLOW-GREEN 446 492T
order codes - end Stops
Type Description Box Qty Type code
Grey Light duty without screw 100 KD4 GREY 495 059
Mid duty with screw 50 KD7 GREY 495 219
Heavy duty with screw 50 KD6 GREY 495 099
Configuration Type Size ratings Dimensions (mm) Box Qty Description code
L W D
One Input – Two Output
Grey 2.5mm 24A/800V~ 64.85 5 43 50 PYK 2.5 E GREY 307 439
Grey 4mm 32A/800V~ 70.8 6 44 50 PYK 4 E GREY 307 229
Earth 2.5mm - 64.85 5 43 50 PYK 2.5 ET YELLOW-GREEN
336 550
Two Input – Two Output
Grey 2.5mm 24A/800V~ 76.4 5 43 20 PYK 2.5 C GREY 307 389
Earth 2.5mm - 76.4 5 43 50 PYK 2.5 CT YELLOW-GREEN
336 540
Suit Terminal Size number of Poles Box Qty Description code
2.5mm 2 25 UK 2.5/2-YBK 2.5 476 222
3 20 UK 2.5/3 2-YBK 2.5 476 223
10 5 UK 2.5/10 2-YBK 2.5 476 229
4mm 2 25 UK 4/2-PYK 4 476 232
3 20 UK 4/3-PYK 4 476 233
10 5 UK 4/10-PYK 4 476 239
Multi Input/Output Terminals make wiring more practical,reduce the installation costs where double and multilevel terminals cannot be used in the panels. Have same features in Earth terminals with same cross sections.
PyK 2.5e grey
PyK 2.5eT yellow-green
KD4
KD7
KD6
17-761
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.3. Warning Labels
order codes
order codes - group markers
markers
Warning Labels
order codes - end covers
Terminal Width Suitable for use with Qty Description code
4mm PYK 1.5 500 DB4* 503 000
5mm AVK 2.5 / PIK 2.5 / PYK 2.5 / PYK 3 500 DG10/5* 505 310
6mm AVK 4 / PIK 4 / PUK / AVK 2.5 / ASK 3 / PYK 4 400 DB10/6* 505 320
8mm AVK 6 / AVK 95...AVK 240 / ASK 2 / WGO 3 / PYK 6 / PYK 4 200 DG10/8* 505 410
10-16mm AVK 10...AVK 35 / PIK 10 / ASK 4 / WGO 2 / PYK 10 / PIK 10 200 DG10/10* 505 430
20-36mm AVK 50...AVK 240 200 KOIPSMW* 508 511
* See table below for available marking ex. DG 10/5-A
0 1-50 A L11 51-100 B L22 101-150 C L33 151-200 D +4 201-300 E -5 301-400 F PE6 401-500 G GND7 501-600 H BLANK8 601-700 I9 701-800 J10 801-900 K1-10 901-1000 L11-20 M21-30 N31-40 O41-50 P51-60 Q61-70 R71-80 S81-90 T91-100 U10-100 V
WXYZ
Siutable for use with Qty Description code
AVK 2.5 ... AVK 10 25 IP 2S 498 130
AVK 16 ... AVK 35RD 25 IP 3S 498 143
PYK 2.5 ... PYK 10 25 IP 4S 498 160
AVK 50...AVK 240 25 IP 5S 498 250
Size Qty Description code
6 x 15mm 25 ME1-1 Transparent 496 12A
10 x 20mm 25 ME1-2 Transparent 496 13A
7 x 44mm 50 ME 3 Transparent 496 300
Standard 50 ME 4 496 119
me1-1 me1-2
me3 me4
17.4. Markers
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
17. TerminaTion & Wiring SySTemS
Discount Code C15
Stock Status:normally stocked /Not normally stocked
17
17.5. Din-Rail17.6. Wiring Duct
order codes
accessories
mounting rail Din 35mm
Description Type Unit Length Pack Qty code
MR 35 x 7.5 Slotted 1 100 500 602
2 20 500 604
Description Type Pack Qty code
RT Angled support bracket 25 501 101
Wiring Ductsorder codes - Slottet Wiring ducts
order codes - Wiring Ducts covers
accessories - Wiring Ducts
order codes - cutting Tool
Description Box Qty Product code
25 x 30 Slotted Wiring Duct 50 x 2m KKC 2530 551 010
25 x 40 Slotted Wiring Duct 50 x 2m KKC 2540 551 011
25 x 60 Slotted Wiring Duct 30 x 2m KKC 2560 551 012
40 x 40 Slotted Wiring Duct 26 x 2m KKC 4040 551 013
40 x 60 Slotted Wiring Duct 18 x 2m KKC 4060 551 014
40 x 80 Slotted Wiring Duct 20 x 2m KKC 4080 551 015
60 x 40 Slotted Wiring Duct 18 x 2m KKC 6040 551 016
60 x 60 Slotted Wiring Duct 12 x 2m KKC 6060 551 017
60 x 80 Slotted Wiring Duct 12 x 2m KKC 6080 551 018
80 x 60 Slotted Wiring Duct 14 x 2m KKC 8060 551 019
80 x 80 Slotted Wiring Duct 12 x 2m KKC 8080 551 020
100 x 60 Slotted Wiring Duct 10 x 2m KKC 1006 551 021
100 x 80 Slotted Wiring Duct 8 x 2m KKC 1008 551 022
120 x 60 Slotted Wiring Duct 8 x 2m KKC 1206 551 023
120 x 80 Slotted Wiring Duct 6 x 2m KKC 1208 551 024
Description Box Qty Product code
25mm Wiring Duct Cover 10 x 2m KKK 25 551 050
40mm Wiring Duct Cover 10 x 2m KKK 40 551 051
60mm Wiring Duct Cover 10 x 2m KKK 60 551 052
80mm Wiring Duct Cover 10 x 2m KKK 80 551 053
100mm Wiring Duct Cover 10 x 2m KKK 100 551 054
120mm Wiring Duct Cover 10 x 2m KKK 120 551 055
Description Box Qty Product code
Wiring Retainer 10 KKT 40x40 553 315
10 KKT 40x60 553 325
10 KKT 40x80 553 335
Cable Clamp 10 KKB 553 405
Cable Holder 10 KKM 553 415
Description Box Qty Product code
Wiring Duct Cutter 1 KKMR 553 230
mr 35 x 7.5
rT
KKmr
17-763
Discount Code C15
Stock Status:Normally stocked /Not normally stocked
17
17.7. Typical Specifications
Wiring Ducts
Wire retainer
cable Holder
Dimensions
DescriptionDimensions (mm)
ProductA B C D E F G H I
Wiring Duct 25 30 11,4 4 6 2,1 4,5 6,5 25 KKC 2530
Wiring Duct 25 40 12,4 4 6 2,1 4,5 6,5 25 KKC 2540
Wiring Duct 25 60 13,6 4 6 2,1 4,5 6,5 25 KKC 2560
Wiring Duct 40 40 12,4 4 6 2,1 4,5 6,5 25 KKC 4040
Wiring Duct 40 60 13,6 4 6 2,1 4,5 6,5 25 KKC 4060
Wiring Duct 40 80 15,8 4 6 2,1 4,5 6,5 25 KKC 4080
Wiring Duct 60 40 12,6 4 6 2,1 4,5 6,5 25 KKC 6040
Wiring Duct 60 60 13,8 4 6 2,1 4,5 6,5 25 KKC 6060
Wiring Duct 60 80 15,8 4 6 2,1 4,5 6,5 25 KKC 6080
Wiring Duct 80 60 13,8 4 6 2,1 4,5 6,5 25 KKC 8060
Wiring Duct 80 80 15,8 4 6 2,1 4,5 6,5 25 KKC 8080
Wiring Duct 100 60 16 4 6 2,1 4,5 6,5 25 KKC 1006
Wiring Duct 100 80 16 4 6 2,1 4,5 6,5 25 KKC 1008
Wiring Duct 120 60 16,3 4 6 2,1 4,5 6,5 25 KKC 1206
Wiring Duct 120 80 16,3 4 6 2,1 4,5 6,5 25 KKC 1208
Wiring Retainer 34 35 KKT 40 x 40
Wiring Retainer 34 53 KKT 40 x 60
Wiring Retainer 53 75 KKT 60 x 80
Cable Clamp 15 11 6 KKB
Cable Holder 83,6 14 15 20 19,8 KKM
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
Product Code Indexindex
index
Find products via their product code listed in alphanumeric order.
Page Number(s)
UB10.241
765
Product Code Index
numeric10GFIBR-XFP-10K 10-47210GFIBR-XFP-40K 10-47210GFIBR-XFP-80K 10-47210GFIBR-XFP-500 10-47210GXFP-MOD 10-47215S60M10100NCHVV1G2STIP50 2-11315S60M10360NCHVV1G2STIP50 2-11315S60M10500NCHVV1G2STIP50 2-11315S60M11000NCHVV1G2STIP50 2-11315T04SF0100NCHVV1G2STIP50 2-11715T04SF0360NCHVV1G2STIP50 2-11715T04SF0500NCHVV1G2STIP50 2-11715T04SF1000NCHVV1G2STIP50 2-11715T05SF0100NCHVV1G2STIP50 2-11715T05SF0360NCHVV1G2STIP50 2-11715T05SF0500NCHVV1G2STIP50 2-11715T05SF1000NCHVV1G2STIP50 2-11726.600 G 5-235, 5-268100-POE4 10-478100-POE-SPL-12 10-479100-POE-SPL-24 10-479100-POE-SPL-48 10-479102MCE-XX-YY 10-483102MC-XX 10-483104TX 10-460105FX-XX 10-460105FX-XX-POE 10-478105FX-XX-YY-POE 10-478105M12 10-474105TX 10-460105TX-POE 10-478, 10-479105TX-SL 10-460106FX2-XX 10-460108M12 10-474108TX 10-460110FX2-XX 10-460110FX2-XX-YY 10-460111FX3-XX 10-460111FX3-XX-YY 10-460112FX4-XX 10-460112FX4-XX-YY 10-460114FX6XX 10-460114FX6XX-YY 10-460116TX 10-460304TX-N 10-463306FX2-N-XX 10-463306FXE2-N-XX-YY 10-463306TX 10-463308FX2-N-XX 10-463308FXE2-N-XX-YY 10-463308TX-N 10-463309FXE-N-XX-YY 10-463309FX-N-XX 10-463316TX-N 10-463317FXE-N-XX-YY 10-463317FX-N-XX 10-463702M12-PK 10-476702M12-W 10-476702-W 10-476702-W-PM 10-476708FX2-XX 10-464708FXE2-XX-YY 10-464708M12 10-475708TX 10-464709FXE-XX-YY 10-464709FX-XX 10-464710FX2-XX 10-464710FXE2-XX-YY 10-464711FX3-XX 10-464711FXE3-XX-YY 10-464712FX4-XX 10-464712FXE4-XX-YY 10-464714FX6-XX 10-464714FXE6-XX-YY 10-464716FX2-XX 10-464716FXE2-XX-YY 10-464716RD60100HVSW 2-113716RD60360HVSW 2-113716RD60500HVSW 2-113716RD61000HVSW 2-113716RD61600HVSW 2-113716RS60100HVSW 2-113716RS60360HVSW 2-113716RS60500HVSW 2-113716RS61000HVSW 2-113716RS61600HVSW 2-113716TX 10-464755HS102FF0100RHVG2ST 2-117755HS102FF0360RHVG2ST 2-117755HS102FF0500RHVG2ST 2-117755HS102FF1000RHVG2ST 2-117755HS104FF0100RHVG2ST 2-117755HS104FF0360RHVG2ST 2-117
755HS104FF0500RHVG2ST 2-117755HS104FF1000RHVG2ST 2-117755RG161MA0100RHVG2ST 2-114755RG161MA0360RHVG2ST 2-114755RG161MA0500RHVG2ST 2-114755RG161MA1000RHVG2ST 2-114755RG161RG0100RHVG2ST 2-114755RG161RG0360RHVG2ST 2-114755RG161RG0500RHVG2ST 2-114755RG161RG1000RHVG2ST 2-114755RG261MA2500RHVG2ST 2-114755RG261RG2500RHVG2ST 2-114760N1T05FB0100NCHVSXSTIP64 2-118760N1T05FB0360NCHVSXSTIP64 2-118760N1T05FB0500NCHVSXSTIP64 2-118760N1T05FB1000NCHVSXSTIP64 2-118760N1T14FB0100NCHVSXSTIP64 2-118760N1T14FB0360NCHVSXSTIP64 2-118760N1T14FB0500NCHVSXSTIP64 2-118760N1T14FB1000NCHVSXSTIP64 2-118760N2T05FB2500NCHVSXSTIP64 2-118760N2T14FB2500NCHVSXSTIP64 2-118925B10FF10360CWPPS19STIP65 2-120925B10FF10500CWPPS19STIP65 2-120925B10FF11000CWPPS19STIP65 2-120925B10FF14096CWPPS19STIP65 2-120958B6FSS260360CWPPSG2STIP65 2-120958B6FSS260500CWPPSG2STIP65 2-120958B6FSS261000CWPPSG2STIP65 2-120958B6FSS264096CWPPSG2STIP65 2-120960T04SF0256GPPG2IP64 2-121960T04SF0360XPPG2IP64 2-121960T04SF0512GPPG2IP64 2-121960T04SF1024GPPG2IP64 2-121960T05SF0256GPPG2IP64 2-121960T05SF0360XPPG2IP64 2-121960T05SF0512GPPG2IP64 2-121960T05SF1024GPPG2IP64 2-1211002MC-LX-ZZ 10-4831002MC-SX 10-4831003GX2-B 10-4611003GX2-LX-ZZ 10-4611003GX2-SX 10-4611005TX 10-4615911 086-4 12-5345911 086-5 12-5345911 086-7 12-5345911 086-11 12-5345911 086-12 12-5345911 086-13 12-5345911 086-14 12-5345911 086-15 12-5346351A-NP9125 3-1476352A-NP9125 3-1476353A-NP9125 3-1476354A-NP9125 3-1476355A-NP9125 3-1476356A-NP9125 3-1476357A-NP9125 3-1476358A-NP9125 3-1476359A-NP9125 3-1476360A-NP9125 3-1476361A-NP9125 3-1476362A-NP9125 3-1476363A-NP9125 3-1476364A-NP9125 3-1476365A-NP9125 3-1476366A-NP9125 3-1476367A-NP9125 3-1476368A-NP9125 3-1476369A-NP9125 3-1476370A-NP9125 3-1476371A-NP9125 3-1476372A-NP9125 3-1476373A-NP9125 3-1476374A-NP9125 3-1476455-B 3-1486455-T 3-1556456-B 3-1486456-T 3-1556458-B 3-1486458-T 3-1556459-B 3-1486459-T 3-1556461-B 3-1486461-T 3-1556462-B 3-1486462-T 3-1556464-B 3-1486464-T 3-1556465-B 3-1486465-T 3-155
6655D-NP9125 3-1546656D-NP9125 3-1546657D-NP9125 3-1546658D-NP9125 3-1546659D-NP9125 3-1546660D-NP9125 3-1546661D-NP9125 3-1546662D-NP9125 3-1546663D-NP9125 3-1546664D-NP9125 3-1546665D-NP9125 3-1546667D-NP9125 3-1546668D-NP9125 3-1546669D-NP9125 3-1546670D-NP9125 3-1546671D-NP9125 3-1546731 3-1456732 3-1456733 3-1456734 3-1456735 3-1456736 3-1456737 3-1456738 3-1456739 3-1456740 3-1456741 3-1456742 3-1456743 3-1456744 3-1456745 3-1456746 3-1456747 3-1456748 3-1456749 3-1456750 3-1456761A-NP9124 3-1466762A-NP9124 3-1466763A-NP9124 3-1466764A-NP9124 3-1466765A-NP9124 3-1466766A-NP9124 3-1466767A-NP9124 3-1466768A-NP9124 3-1466769A-NP9124 3-1466770A-NP9124 3-1466771A-NP9124 3-1466772A-NP9124 3-1466773A-NP9124 3-1466774A-NP9124 3-1466775A-NP9124 3-1466776A-NP9124 3-1466777A-NP9124 3-1466778A-NP9124 3-1466779A-NP9124 3-1466780A-NP9124 3-1466781A-NP9124 3-1466782A-NP9124 3-1466783A-NP9124 3-1466784A-NP9124 3-1466835 3-1526836 3-1526837 3-1526838 3-1526839 3-1526840 3-1526841 3-1526842 3-1526843 3-1526844 3-1526845 3-1526846 3-1526847 3-1526848 3-1526849 3-1526850 3-1526865D-NP9124 3-1536866D-NP9124 3-1536867D-NP9124 3-1536868D-NP9124 3-1536869D-NP9124 3-1536870D-NP9124 3-1536871D-NP9124 3-1536872D-NP9124 3-1536873D-NP9124 3-1536874D-NP9124 3-1536875D-NP9124 3-1536876D-NP9124 3-1536877D-NP9124 3-1536878D-NP9124 3-1536879D-NP9124 3-1536880D-NP9124 3-1537010TX 10-4667012FX2-XX 10-4667012FXE2-XX-YY 10-4667018FX2-XX 10-466
7018FXE2-XX-YY 10-4667018TX 10-4667026TX 10-4667026TX-AC 10-4667051A-NP9134 3-1497053A-NP9134 3-1497055A-NP9134 3-1497057A-NP9134 3-1497059A-NP9134 3-1497071 3-1497071-T 3-1567073 3-1497073-T 3-1567075 3-1497075-T 3-1567076 3-1497076-T 3-1567077 3-1497077-T 3-1567081 3-1497081-T 3-1567083 3-1497083-T 3-1567085 3-1497085-T 3-1567086 3-1497086-T 3-1567087 3-1497087-T 3-1567111-B 3-1507111-T 3-1577113-B 3-1507113-T 3-1577115-B 3-1507115-T 3-1577116-B 3-1507116-T 3-1577117-B 3-1507117-T 3-1577121-B 3-1507121-T 3-1577123-B 3-1507123-T 3-1577125-B 3-1507125-T 3-1577126-B 3-1507126-T 3-1577127-B 3-1507127-T 3-1577153-B 3-1507153-T 3-1577154-B 3-1507154-T 3-1577155-B 3-1507155-T 3-1577156-B 3-1507156-T 3-1577157-B 3-1507157-T 3-1577163-B 3-1507163-T 3-1577164-B 3-1507164-T 3-1577165-B 3-1507165-T 3-1577166-B 3-1507166-T 3-1577167-B 3-1507167-T 3-1577403-B 3-1517403-T 3-1587404-B 3-1517404-T 3-1587405-B 3-1517405-T 3-1587406-B 3-1517406-T 3-1587407-B 3-1517407-T 3-1587506GX2 10-4667506GX2-LX-10 10-4667506GX2-SX 10-4667900CPU 10-4698020-CE-RH 7-3878021-CE-LH 7-3878041-CC-35 7-3878042-CC-85 7-3878043-CC-12 7-3878044-CC-20 7-3878080-FC-10 7-3878081-FC-20 7-3878082-FC-30 7-3878085-FC-10 7-3878086-FC-20 7-3878087-FC-30 7-3878101-HI-TX 7-386
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
8102-HO-IP 7-3868103-AI-TX 7-3868104-AO-IP 7-3868105-TI-TC 7-3868106-TI-RT 7-3868109-DI-DC 7-3868110-DI-DC 7-3868111-DI-AC 7-3868112-DI-AC 7-3868113-DI-AC 7-3868114-DI-AC 7-3868115-DO-DC 7-3868116-DO-AC 7-3868117-DO-DC 7-3868118-DO-AC 7-3868119-VI-05 7-3868121-DI-DC 7-3868122-DI-DC 7-3868123-PI-QU 7-3868125-DI-DC 7-3868127-DI-SE 7-3868129-IO-DC 7-3868132-AI-UN 7-3868133-HI-TX 7-3868410-NS-PS 7-3868413-FK-DN 7-3878414-FK-SU 7-3878521-EB-MT 7-3868521-HC-MT 7-3868521-LC-MT 7-3868521-PC-MT 7-3868601-FT-NI 7-3878602-FT-ST 7-3878603-FT-FU 7-3878604-FT-FU 7-3878605-FT-TC 7-3878606-FT-RT 7-3878607-FT-TC 7-3878608-FT-NI 7-3878610-FT-NA 7-3878611-FT-FU 7-3878615-FT-4W 7-3878617-FT-NI 7-3878618-FT-MT 7-3878619-FT-MT 7-3878650-FT-PX 7-3878707-CA-08 7-3878709-CA-08 7-3878710-CA-04 7-3878750-CA-NS 7-3868913-PS-AC 5A 7-3878914-PS-AC 7-3879000B-FP 10-4699000BP 10-4699000-PM 10-4699000-UTA107 10-4699002FXE-XX-YY 10-4699002FX-XX 10-4699004FXE-XX-YY 10-4699004FX-XX 10-4699006TX 10-46977612CBA0100RHVG2ST 2-11877612CBA0256RHVG2ST 2-11877612CBA0512RHVG2ST 2-11877612CBA1000RHVG2ST 2-118702110F1S0100RHV1SYSTIP65 2-114702110F1S0360RHV1SYSTIP65 2-114702110F1S0500RHV1SYSTIP65 2-114702110F1S1000RHV1SYSTIP65 2-114702110FF0100RHV1SYSTIP65 2-114702110FF0360RHV1SYSTIP65 2-114702110FF0500RHV1SYSTIP65 2-114702110FF1000RHV1SYSTIP65 2-114702210F1S2500RHV1SYSTIP65 2-114702210FF2500RHV1SYSTIP65 2-114702310F1S5000RHV1SYSTIP65 2-114702310FF5000RHV1SYSTIP65 2-114725110FF10100RHV1SYSTIP65 2-115725110FF10360RHV1SYSTIP65 2-115725110FF10500RHV1SYSTIP65 2-115725110FF11000RHV1SYSTIP65 2-115725110FS10100RHV1SYSTIP65 2-115725110FS10360RHV1SYSTIP65 2-115725110FS10500RHV1SYSTIP65 2-115725110FS11000RHV1SYSTIP65 2-115725210FF12500RHV1SYSTIP65 2-115725210FS12500RHV1SYSTIP65 2-115725310FF15000RHV1SYSTIP65 2-115725310FS15000RHV1SYSTIP65 2-115745112KS0100RHV1SXSTIP64 2-116745112KS0360RHV1SXSTIP64 2-116745112KS0500RHV1SXSTIP64 2-116745112KS1000RHV1SXSTIP64 2-116745112KS2500RHV1SXSTIP64 2-116745112KS5000RHV1SXSTIP64 2-116745112KS10000RHV1SXSTIP64 2-116
758110F200100RHVSG2STIP65 2-115758110F200360RHVSG2STIP65 2-115758110F200500RHVSG2STIP65 2-115758110F201000RHVSG2STIP65 2-115758110F260100RHVSG2STIP65 2-115758110F260360RHVSG2STIP65 2-115758110F260500RHVSG2STIP65 2-115758110F261000RHVSG2STIP65 2-115758210F202500RHVSG2STIP65 2-115758210F262500RHVSG2STIP65 2-115758310F205000RHVSG2STIP65 2-115758310F265000RHVSG2STIP65 2-115758310F2010000RHVSG2STIP65 2-115758310F2610000RHVSG2STIP65 2-115776135BA0100RHVG2ST 2-118776135BA0256RHVG2ST 2-118776135BA0512RHVG2ST 2-118776135BA1000RHVG2ST 2-118858110F200100RHVSG2STIP65 2-116858110F200360RHVSG2STIP65 2-116858110F200500RHVSG2STIP65 2-116858110F201000RHVSG2STIP65 2-116858110F260100RHVSG2STIP65 2-116858110F260360RHVSG2STIP65 2-116858110F260500RHVSG2STIP65 2-116858110F261000RHVSG2STIP65 2-116858210F202500RHVSG2STIP65 2-116858210F262500RHVSG2STIP65 2-116858310F205000RHVSG2STIP65 2-116858310F265000RHVSG2STIP65 2-116858310F2010000RHVSG2STIP65 2-116858310F2610000RHVSG2STIP65 2-1161087930 2-61, 2-59, 2-60, 6-3311155097SS 2-61, 2-59, 2-60, 6-3311186490 2-61, 2-59, 2-60, 6-3311186696 2-61, 2-59, 2-60, 6-3311192471 2-61, 2-59, 2-60, 6-3311203476 2-61, 2-59, 2-60, 6-3311203478 2-61, 2-59, 2-60, 6-331
Alphabetical
AA 16-04-00** 14-634A 40-30-01** 14-630A 40-30-10** 14-630A 45-22-00** 14-634A 45-40-00** 14-634A 50-30-11** 14-630A 50-40-00** 14-634A 63-30-11** 14-630A 75-22-00** 14-634A 75-30-11** 14-630A 75-40-00** 14-634A 95-30-11** 14-630A 110-30-11** 14-630A 145-30-11** 14-630A 185-30-11** 14-630A 210-30-11** 14-630A 260-30-11** 14-630A300-30-10** 14-630AA4-24 14-644AA4-110 14-644AA4-230 14-644AA4-400 14-644AA1206 12-541AA1560 12-541AA5190 12-541AA5200 12-541AA5600 12-541AA8001 12-541AA8002 12-541AA8003 12-541AA8025 12-541AA8050 12-541ACC RSS 36-SK 6-300ACH550 14-605, 14-613ACH550-01-02A4-4+B055 14-613ACH550-01-03A3-4+B055 14-613ACH550-01-04A1-4+B055 14-613ACH550-01-05A4-4+B055 14-613ACH550-01-06A9-4+B055 14-613ACH550-01-08A8-4+B055 14-613ACH550-01-012A-4+B055 14-613ACH550-01-015A-4+B055 14-613ACH550-01-023A-4+B055 14-613ACH550-01-031A-4+B055 14-613ACH550-01-038A-4+B055 14-613ACH550-01-045A-4+B055 14-613ACH550-01-059A-4+B055 14-613ACH550-01-072A-4+B055 14-613
ACH550-01-087A-4+B055 14-613ACH550-01-125A-4+B055 14-613ACH550-01-157A-4+B055 14-613ACH550-01-180A-4+B055 14-613ACH550-01-195A-4+B055 14-613ACH550-01-246A-4+B055 14-613ACH550-01-290A-4+B055 14-613ACQ810 14-605, 14-614ACS55 14-605, 14-606ACS55-01E-01A4-2 14-606ACS55-01E-02A2-2 14-606ACS55-01E-04A3-2 14-606ACS55-01E-07A6-2 14-606ACS55-01E-09A8-2 14-606ACS55-POT 14-606ACS150 14-605, 14-607ACS150-01E-02A4-2 14-607ACS150-01E-04A7-2 14-607ACS150-01E-06A7-2 14-607ACS150-01E-07A5-2 14-607ACS150-01E-09A8-2 14-607ACS150-03E-01A2-4 14-607ACS150-03E-01A9-4 14-607ACS150-03E-02A4-4 14-607ACS150-03E-03A3-4 14-607ACS150-03E-04A1-4 14-607ACS150-03E-05A6-4 14-607ACS150-03E-07A3-4 14-607ACS150-03E-08A8-4 14-607ACS310 14-605, 14-608ACS310-03E-01A3-4 14-608ACS310-03E-02A1-4 14-608ACS310-03E-02A6-4 14-608ACS310-03E-03A6-4 14-608ACS310-03E-04A5-4 14-608ACS310-03E-06A2-4 14-608ACS310-03E-08A0-4 14-608ACS310-03E-09A7-4 14-608ACS310-03E-13A8-4 14-608ACS310-03E-17A2-4 14-608ACS310-03E-25A4-4 14-608ACS310-03E-34A1-4 14-608ACS310-03E-41A8-4 14-608ACS310-03E-48A4-4 14-608ACS355 14-605, 14-609, 14-610ACS355-01E-02A4-2 14-609ACS355-01E-04A7-2 14-609ACS355-01E-06A7-2 14-609ACS355-01E-07A5-2 14-609ACS355-01E-09A8-2 14-609ACS355-03E-01A2-4 14-609ACS355-03E-01A2-4+B063 14-610ACS355-03E-01A9-4 14-609ACS355-03E-01A9-4+B063 14-610ACS355-03E-02A4-4 14-609ACS355-03E-02A4-4+B063 14-610ACS355-03E-03A3-4 14-609ACS355-03E-03A3-4+B063 14-610ACS355-03E-04A1-4 14-609ACS355-03E-04A1-4+B063 14-610ACS355-03E-05A6-4 14-609ACS355-03E-05A6-4+B063 14-610ACS355-03E-07A3-4 14-609ACS355-03E-07A3-4+B063 14-610ACS355-03E-08A8-4 14-609ACS355-03E-08A8-4+B063 14-610ACS355-03E-12A5-4 14-609ACS355-03E-12A5-4+B063 14-610ACS355-03E-15A6-4 14-609ACS355-03E-15A6-4+B063 14-610ACS355-03E-23A1-4 14-609ACS355-03E-31A0-4 14-610ACS355-03E-38A0-4 14-610ACS355-03E-44A0-4 14-610ACS550 14-605, 14-611, 14-612ACS550-01-03A3-4+0J400 14-611ACS550-01-03A3-4+B055+0J400 14-612ACS550-01-04A1-4+0J400 14-611ACS550-01-04A1-4+B055+0J400 14-612ACS550-01-05A4-4+0J400 14-611ACS550-01-05A4-4+B055+0J400 14-612ACS550-01-06A9-4+0J400 14-611ACS550-01-06A9-4+B055+0J400 14-612ACS550-01-08A8-4+0J400 14-611ACS550-01-08A8-4+B055+0J400 14-612ACS550-01-012A-4+0J400 14-611ACS550-01-012A-4+B055+0J400 14-612ACS550-01-015A-4+0J400 14-611ACS550-01-015A-4+B055+0J400 14-612ACS550-01-023A-4+0J400 14-611ACS550-01-023A-4+B055+0J400 14-612ACS550-01-031A-4+0J400 14-611ACS550-01-031A-4+B055+0J400 14-612ACS550-01-038A-4+0J400 14-611ACS550-01-038A-4+B055+0J400 14-612ACS550-01-045A-4+0J400 14-611
ACS550-01-045A-4+B055+0J400 14-612ACS550-01-059A-4+0J400 14-611ACS550-01-059A-4+B055+0J400 14-612ACS550-01-072A-4+0J400 14-611ACS550-01-072A-4+B055+0J400 14-612ACS550-01-087A-4+0J400 14-611ACS550-01-087A-4+B055+0J400 14-612ACS550-01-125A-4+0J400 14-611ACS550-01-125A-4+B055+0J400 14-612ACS550-01-157A-4+0J400 14-611ACS550-01-157A-4+B055+0J400 14-612ACS550-01-180A-4+0J400 14-611ACS550-01-180A-4+B055+0J400 14-612ACS550-01-195A-4+0J400 14-611ACS550-01-195A-4+B055+0J400 14-612ACS550-01-246A-4+0J400 14-611ACS550-01-246A-4+B055+0J400 14-612ACS550-01-290A-4+0J400 14-611ACS550-01-290A-4+B055+0J400 14-612ACS800 14-605, 14-615, 14-616ACS850 14-605, 14-617ACS-CP-B 14-613ACS-CP-C 14-608, 14-610, 14-612ACS-CP-D 14-608, 14-610, 14-612ACS/H-CP-EXT 14-608, 14-610, 14-612, 14-613ACS/H-CP-EXT-IP66 14-608, 14-610, 14-612, 14-613AE 45-22-00** 14-634AE 45-40-00** 14-634AE50-30-11** 14-630AE63-30-11** 14-630AE 75-22-00** 14-634AE75-30-11** 14-630AE 75-40-00** 14-634AE95-30-11** 14-630AE110-30-11** 14-630AF09-22-00** 14-633AF09-30-01** 14-632AF09-30-10** 14-632AF09-40-00** 14-633AF09Z-22-00** 14-634AF09Z-30-01** 14-631AF09Z-30-10** 14-631AF09Z-40-00** 14-634AF12-30-01** 14-632AF12-30-10** 14-632AF12Z-30-01** 14-631AF12Z-30-10** 14-631AF16-22-00** 14-633AF16-30-01** 14-632AF16-30-10** 14-632AF16-40-00** 14-633AF16Z-22-00** 14-634AF16Z-30-01** 14-631AF16Z-30-10** 14-631AF16Z-40-00** 14-634AF26-22-00** 14-633AF26-30-00** 14-632AF26-30-11** 14-632AF26-40-00** 14-633AF26Z-22-00** 14-634AF26Z-30-00** 14-631AF26Z-30-11** 14-631AF26Z-40-00** 14-634AF30-30-00** 14-632AF30-30-11** 14-632AF30Z-30-00** 14-631AF30Z-30-11** 14-631AF38-22-00** 14-633AF38-30-00** 14-632AF38-30-11** 14-632AF38-40-00** 14-633AF38Z-22-00** 14-634AF38Z-30-00** 14-631AF38Z-30-11** 14-631AF38Z-40-00** 14-634AF45-22-00** 14-633AF45-40-00** 14-633AF50-30-11** 14-632AF50-40-00** 14-633AF63-30-11** 14-632AF75-22-00** 14-633AF75-30-11** 14-632AF75-40-00** 14-633AF95-30-00** 14-632AF110-30-11** 14-632AF145-30-11** 14-632AF185-30-11** 14-632AF210-30-11** 14-632AF260-30-11** 14-632AF300-30-11** 14-632AF400-30-11** 14-632AF460-30-11** 14-632AF580-30-11** 14-632AF750-30-11** 14-632
767
Product Code Index
AF1350-30-11** 14-632AF1650-30-11** 14-632AF2050-30-11** 14-632AFCM0000 11-505AFP7AD4H 7-363AFP7CCM1 7-363AFP7CCM2 7-363AFP7CCS1 7-363AFP7CCS1M1 7-363AFP7CCS2 7-363AFP7CPS3 7-363AFP7CPS3E 7-363AFP7CPS4E 7-363AFP7DA4H 7-363AFP7PHLSM 7-364AFP7PP02L 7-364AFP7PP02T 7-364AFP7PP04L 7-364AFP7PP04T 7-364AFP7PSA1 7-363AFP7PSA2 7-363AFP7X16DW 7-363AFP7X32D2 7-363AFP7X64D2 7-363AFP7XY64D2P 7-363AFP7XY64D2T 7-363AFP7Y16P 7-363AFP7Y16R 7-363AFP7Y16T 7-363AFP7Y32P 7-363AFP7Y32T 7-363AFP7Y64P 7-363AFP7Y64T 7-363AFP0523N 7-346, 7-352AFPRP1X08D2 7-364AFPRP1X16D2 7-364AFPRP1XY16D2T 7-364AFPRP1Y16T 7-364AFPRP2X08D2E 7-364AFPRP2X16D2 7-364AFPRP2XY16D2T 7-364AFPRP2Y04R 7-364AFPRP2Y16T 7-364AFPX-A21 7-350AFPX-AD2 7-350AFPX-BATT 7-352, 7-364, 8-418AFPX-C14P 7-350AFPX-C14PD 7-350AFPX-C14R 7-350AFPX-C14RD 7-350AFPX-C14T 7-350AFPX-C14TD 7-350AFPX-C30P 7-350AFPX-C30PD 7-350AFPX-C30R 7-350AFPX-C30RD 7-350AFPX-C30T 7-350AFPX-C30TD 7-350AFPX-C38AT-S 7-350AFPX-C60P 7-350AFPX-C60PD 7-350AFPX-C60R 7-350AFPX-C60RD 7-350AFPX-C60T 7-350AFPX-C60TD 7-350AFPX-COM1 7-351AFPX-COM2 7-351AFPX-COM3 7-351AFPX-COM4 7-351AFPX-COM5 7-351AFPX-COM6 7-351AFPX-DA2 7-350AFPX-E14YR 7-350AFPX-E16P 7-350AFPX-E16R 7-350AFPX-E16T 7-350AFPX-E16X 7-350AFPX-E30P 7-350AFPX-E30PD 7-350AFPX-E30R 7-350AFPX-E30RD 7-350AFPX-E30T 7-350AFPX-E30TD 7-350AFPX-EC08 7-352AFPX-EC30 7-352AFPX-EC80 7-352AFPX-EFP0 7-352AFPX-IN4T3 7-350AFPX-IN8 7-350AFPX-MRTC 7-351AFPX-PLS 7-351AFPX-RTD2 7-350AFPX-TAN1 7-352AFPX-TC2 7-350AFPX-TR6P 7-350AFPX-TR8 7-350
AHKA21P 1-27AHN111X1 1-25AHN111Y2 1-25AHN211X1 1-25AHN211Y2 1-25AHN11124 1-25AHN12112 1-25AHN12124 1-25AHN12148 1-25AHN12312 1-25AHN12324 1-25AHN21124 1-25AHN22112 1-25AHN22124 1-25AHN22312 1-25AHN22324 1-25AHNA11P 1-25AHNA21P 1-25AIG02GQ02D 8-418AIG02GQ04D 8-418AIG02GQ12D 8-418AIG02GQ14D 8-418AIG02GQ22D 8-418AIG02GQ24D 8-418AIG03MQ03DE 8-418AIG03MQ05DE 8-418AIG03TQ13DE 8-418AIG03TQ15DE 8-418AIG12GQ12D 8-419AIG12GQ14D 8-419AIG12MQ12D 8-419AIG12MQ14D 8-419AIG32MQ02D 8-420AIG32MQ03DE 8-420AIG32MQ04D 8-420AIG32MQ05DE 8-420AIG32TQ02D 8-420AIG32TQ03DE 8-420AIG32TQ04D 8-420AIG32TQ05DE 8-420AIG32TQ12D 8-420AIG32TQ14D 8-420AIG03810E 8-418AIGT8001V2 8-418, 8-419, 8-420, 8-421AIGT8142 (N) 8-418AIGT8142 N 8-418AIGT8192 8-418AIGT8192 (N) 8-418, 8-419, 8-420AIGT8192 N 8-418, 8-419, 8-420AIMI0202 11-505A-K4P-M12-S-G-2M-BK-2-X-A-1 2-94, 2-98A-K4P-M12-S-G-5M-BK-2-X-A-1 2-94, 2-98A-K4P-M12-S-G-10M-BK-2-X-A-1 2-94, 2-98A-K4P-M12-S-W-2M-BK-2-X-A-1 2-94, 2-98A-K4P-M12-S-W-5M-BK-2-X-A-1 2-94, 2-98A-K4P-M12-S-W-10M-BK-2-X-A-1 2-94, 2-98A-K6P-M8-R-G-5M-GY-1-X-A-4 6-297A-K8P-M12-S-G-5M-BK-1-X-A-2 6-308, 6-309A-K8P-M12-S-G-5M-BK-1-X-A-4-69 6-309A-K8P-M12-S-G-10M-BK-1-X-A-2 6-308, 6-309AKT4H111100 4-199AKT4H111200 4-199AKT4H112100 4-199AKT4H113100 4-199AKT4H211100 4-199AKT2111200 4-198AKT4111100 4-198AKT4111140 4-198AKT4111200 4-198AKT4112100 4-198AKT4113100 4-198AKT4211100 4-198AKT7111100 4-199AKT7112100 4-199AKT7113100 4-199AKT7211100 4-199AKT8111100 4-200AKT8112100 4-200AKT8113100 4-200AKT9111100 4-200AKT9112100 4-200AKT9113100 4-200AL40-30-01** 14-630AL40-30-10** 14-630AM1300KF 2-50AM1301KF 2-50AM1303KF 2-50AM1305KF 2-50
AM1306KF 2-50AM1307KF 2-50AM1701KF 2-50AM1703KF 2-50AM1704KF 2-50AM1711KF 2-50AM1714KF 2-50AM1731KF 2-50AM1734KF 2-50AM1743KF 2-50AM51610C53-A 2-50AM51611C53-A 2-50AM51612C53-A 2-50AM51613C53-A 2-50AM51614C53-A 2-50AM51615C53-A 2-50AM51616C53-A 2-50AM130811KF 2-50AM130812KF 2-50ANT5DB5M 4-225, 7-403, 8-412, 10-480, 11-494, 11-495, 11-496ANT7DB5M 4-225, 7-403, 8-412, 10-480, 11-494, 11-495, 11-496ANT-CAB-195-RPSMA-RPSMA-X 10-476ANT-CAB-400-N-RPSMA-X 10-476ANT-CAB-400-N-RPTNC-X 10-476ANT-CAB-400-N-X 10-476ANT-LA6-NFF 10-476ANT-MD24-12 10-476ANT-PAD24-16 10-476ANT-PAD58-19 10-476ANT-PD58-32 10-476APP 2.5-10 GREY 17-744APP 16 GREY 17-744APP/AVK 35 RD GREY 17-744APP PYK 1.5 GREY 17-755APP PYK 6 GREY 17-755APP PYK 10 GREY 17-755APSCM010 4-201, 4-202, 4-203, 4-204, 4-205, 4-211APSCM100 4-201, 4-202, 4-203, 4-204, 4-205, 4-211AQA211VL 1-30AQA221VL 1-30AQA411VL 1-30AQA421VL 1-30AQA611VL 1-30AQA621VL 1-30AQA801 1-30AQAD551DL 1-30AQP-DPJ 1-30AQP- HS-30/40A 1-30AQP-HS-J10A 1-30AQP-HS-J25A 1-30AQP-HS-SJ20A 1-30ASK 2 B GREY 17-750ASK 2S GREY 17-752ASK 3 A GREY 17-750ASK 3F GREY 17-752ASK 3 MB GREY 17-750ASK 4 B GREY 17-750AT8-DA4 1-34, 1-38, 1-39, 1-40, 1-41AT8-DF8K 1-34, 1-38, 1-39, 1-40, 1-41AT8-DF11K 1-34, 1-38, 4-180AT8-R8K 1-34, 1-38, 1-39, 1-40, 1-41AT8-R11K 1-34, 1-38, 4-180ATB71918 1-42ATB75017 1-42ATC18002 1-34ATHD4V40SRS 4-226ATHDV12 4-226AVK 2.5/4T YELLOW-GREEN 17-743AVK 2.5 BLUE 17-743AVK 2.5 EA GREY 17-750AVK 2.5 GREY 17-743AVK 4 BLUE 17-743AVK 4 GREY 17-743AVK 6/10T YELLOW-GREEN 17-743AVK 6 BLUE 17-743AVK 6 GREY 17-743AVK 10 BLUE 17-743AVK 10 GREY 17-743AVK 16 BLUE 17-743AVK 16 GREY 17-743AVK 16TRD YELLOW-GREEN 17-743AVK 35 BLUE 17-743AVK 35 GREY 17-743AVK 35TRD YELLOW-GREEN 17-743AVK50 GREY 17-745AVK 50T YELLOW-GREEN 17-743AVK70 RD GREY 17-745AVK95B GREY 17-746AVK95 GREY 17-745AVK150B GREY 17-746AVK150 GREY 17-745AVK240B GREY 17-746
AVK240 GREY 17-745AVK/EK6 17-745AXY52000FP 7-346AZ 15/16-B1 6-290AZ 15/16-B1 – 1747 6-290AZ 15/16-B1 – 2024 6-290AZ 15/16-B1 – 2053 6-290AZ 15/16-B1 – 2177 6-290AZ 15/16-B2 6-290AZ 15/16-B2 – 1747 6-290AZ 15/16-B3 6-290AZ 15/16-B3 – 1747 6-290AZ 15/16-B6 6-290AZ 15-ZVK-M20 6-289AZ 15-ZVRK-M20 6-289AZ 16-02ZVK-M20 6-289AZ 16-02ZVRK-M20 6-289AZ 16-03ZVK-M20 6-289AZ 16-03ZVRK-M20 6-289AZ 16-12ZVK-M20 6-289AZ 16-12ZVRK-M20 6-289AZ 16ZVK-M20 6-289AZ 16ZVRK-M20 6-289AZ 17-02ZK 6-288AZ 17-11ZK 6-288AZ 17/170-B1 6-288, 6-301AZ 17/170-B1-2245 6-288, 6-301AZ 17/170-B5 6-288, 6-301AZ 17/170-B11 6-288, 6-301AZ 17/170-B15 6-288, 6-301AZ 17-B6 6-288AZ 200SK-T-1P2P 6-293AZ 415-02/02ZPK-M20 6-292AZ 415-11/11ZPK-M20 6-292AZ 3350-03ZK 6-291AZ 3350-12ZUEK 6-291AZ 3350-B1 6-291AZ 3350-B5 6-291AZ 3350-B6 6-291AZ/AZM 200 - B1-LT 6-306AZ/AZM 200-B1-LT 6-293AZ/AZM 200 - B1-RT 6-306AZ/AZM 200-B1-RT 6-293AZ/AZM 200 - B30-LTAG1 6-306AZ/AZM 200-B30-LTAG1 6-293AZ/AZM 200 - B30-LTAG1P1 6-306AZ/AZM 200-B30-LTAG1P1 6-293AZ/AZM 200 - B30-RTAG1 6-306AZ/AZM 200-B30-RTAG1 6-293AZ/AZM 200 - B30-RTAG1P1 6-306AZ/AZM 200-B30-RTAG1P1 6-293AZ/AZM 300-B1 6-304AZ/AZM 415 B1 6-307AZ/AZM 415-B1 6-292AZ/AZM 415 B2 6-307AZ/AZM 415-B2 6-292AZ/AZM 415 B3 6-307AZ/AZM 415-B3 6-292AZ/AZM 415 B4PS 6-307AZ/AZM 415-B4PS 6-292AZM 161-B1 6-302AZM 161-B1-2177 6-302AZM 161-B6 6-302AZM 161-B6 -2177 6-302AZM 161SK-12/12RK 24VACDC 6-302AZM 161SK-12/12RK 110/230VAC 6-302AZM 161SK-12/12RKA 24VACDC 6-302AZM 161SK-12/12RKA 110/230VAC 6-302AZM 170-B6 6-301AZM 170SK-02ZRK-2197 24VACDC 6-301AZM 170SK-02ZRKA 24VACDC 6-301AZM 170SK-11ZRK-2197 24VACDC 6-301AZM 170SK-11ZRK-2197 230VAC 6-301AZM 170SK-11ZRKA 24VACDC 6-301AZM 170SK-11ZRKA 240VAC 6-301AZM 190-02/10RKA-M20 24VACDC 6-303AZM 190-02/10RK-M20 24VACDC 6-303AZM 190-11/01RKA-M20 24VACDC 6-303AZM 190-11/01RK-M20 24VACDC 6-303AZM 190 - B1 6-303AZM 190 - B3/2x15 6-303AZM 200SK-T-1P2PW 6-306AZM 200SK-T-1P2PWA 6-306AZM300 6-305AZM300B-I1-ST-1P2P 6-304AZM300B-I1-ST-1P2P-A 6-304AZM300B-I1-ST-SD2P 6-304AZM300B-I1-ST-SD2P-A 6-304AZM300B-I2-ST-1P2P 6-304AZM300B-I2-ST-1P2P-A 6-304AZM300B-I2-ST-SD2P 6-304AZM300B-I2-ST-SD2P-A 6-304AZM300B-ST-1P2P 6-304AZM300B-ST-1P2P-A 6-304AZM300B-ST-SD2P 6-304AZM300B-ST-SD2P-A 6-304
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
AZM300Z-I1-ST-1P2P 6-304AZM300Z-I1-ST-1P2P-A 6-304AZM300Z-I1-ST-SD2P 6-304AZM300Z-I1-ST-SD2P-A 6-304AZM300Z-I2-ST-1P2P 6-304AZM300Z-I2-ST-1P2P-A 6-304AZM300Z-I2-ST-SD2P 6-304AZM300Z-I2-ST-SD2P-A 6-304AZM300Z-ST-1P2P 6-304AZM300Z-ST-1P2P-A 6-304AZM300Z-ST-SD2P 6-304AZM300Z-ST-SD2P-A 6-304AZM 415-11/11ZPK 24VACDC 6-307AZM 415-11/11ZPK 230VAC 6-307AZM 415-11/11ZPKA 24VACDC 6-307AZM 415-11/11ZPKA 230VAC 6-307AZM 415-11/11ZPKF 24VACDC 6-307AZR 31 S1 24 VAC 6-322AZR 31 S1 24 VDC 6-322AZR 31 S1 230 VAC 6-322AZS 2305 6-323
BBAROLI 02 5-274BAROLI 05 5-275BDL4245E 4-226BE 20 2-108BEA16-4 14-639BEA38-4 14-639BEA7116 14-647BEA16116 14-647BEAL16116AL 14-647BEM75-30 14-637BEM110-30 14-637BEM185-30 14-637BEM300-30 14-637BEM460-30 14-637BEM750-30 14-637BER16-4 14-639BER38-4 14-639BES75-30 14-637BES110-30 14-637BES185-30 14-637BES300-30 14-637BES460-30 14-637BES750-30 14-637BEY16-4 14-639BEY38-4 14-639BFM136 15-660BMK60000 4-179, 4-182, 4-184, 4-187, 4-189, 4-201, 4-203, 4-208, 4-210, 4-216BMK80000 1-43, 4-178BMK90000 4-179, 4-181, 4-182, 4-183, 4-185, 4-186, 4-187, 4-188, 4-189, 4-190, 4-191, 4-192, 4-197, 4-201, 4-202, 4-203, 4-204, 4-205, 4-206, 4-207, 4-208, 4-209, 4-210, 4-211, 4-212, 4-213, 4-214, 4-215, 4-216, 4-217, 4-218, 4-219, 4-220, 4-221BN 20-01Z 2-108BN 20-2RZ 2-108BN 20-02Z 2-108BN 20-10Z 2-108BN 20-11RZ 2-108BN 20-11Z 2-108BN 20-20Z 2-108BN 20-RZ 2-108BN 65-10Z/V 2-108BN 65-RZ 2-108BN 80-01Z 2-109BN 80-10Z 2-109BN 85-R 2-109BN 310-01Z 2-108BN 310-10Z 2-108BN 310-RZ 2-108BNS 16-12ZD 6-294BNS 16-12ZL 6-294BNS 16-12ZLR 6-294BNS 16-12ZR 6-294BNS 16-12ZU 6-294BNS 16-12ZV 6-294BNS 33-02Z-2187 6-295BNS 33-02Z-2187 5M 6-295BNS 33-02Z-2187 10M 6-295BNS 33-02ZG-2187 6-295BNS 33-02ZG-2187 5M 6-295BNS 33-11Z 6-295BNS 33-11Z 5M 6-295BNS 33-11Z 10M 6-295BNS 33-11ZG 6-295BNS 33-11ZG 5M 6-295BNS 33-11ZG 10M 6-295BNS 33-12Z-2187 6-295BNS 33-12Z-2187 5M 6-295BNS 33-12ZG 6-295
BNS 33-12ZG 5M 6-295BNS 33-12ZG 10M 6-295BNS 33-12ZG-2187 6-295BNS 33-12ZG-2187 5M 6-295BNS 33-12ZG-2187 10M 6-295BNS 40S-12Z 6-299BNS 40S-12Z 5M 6-299BNS 40S-12Z 10M 6-299BNS 40S-12Z-C 6-299BNS 40S-12Z-C 5M 6-299BNS 40S-12Z-C 10M 6-299BNS 40S-12ZG 6-299BNS 40S-12ZG 5M 6-299BNS 40S-12ZG 10M 6-299BNS 40S-12ZG-C 6-299BNS 40S-12ZG-C 5M 6-299BNS 40S-12ZG-C 10M 6-299BNS 250-11Z 6-296BNS 250-11Z 5M 6-296BNS 250-11Z 10M 6-296BNS 250-11ZG 6-296BNS 250-11ZG 5M 6-296BNS 250-11ZG 10M 6-296BNS 250-12Z 6-296BNS 250-12Z 5M 6-296BNS 250-12Z 10M 6-296BNS 250-12Z-2187 6-296BNS 250-12Z-2187 5M 6-296BNS 250-12ZG 6-296BNS 250-12ZG 5M 6-296BNS 250-12ZG 10M 6-296BNS 260-02/01ZG-ST-L 6-297BNS 260-02/01ZG-ST-R 6-297BNS 260-02/01Z-L 5M 6-297BNS 260-02/01Z-R 5M 6-297BNS 260-02/01Z-ST-L 6-297BNS 260-02/01Z-ST-R 6-297BNS 303-11Z 6-298BNS 303-11Z 5M 6-298BNS 303-11Z 10M 6-298BNS 303-11ZG 6-298BNS 303-11ZG 5M 6-298BNS 303-11ZG 10M 6-298BNS 303-12Z 6-298BNS 303-12Z 5M 6-298BNS 303-12Z 10M 6-298BNS 303-12Z-2187 5M 6-298BNS 303-12ZG 6-298BNS 303-12ZG 5M 6-298BNS 303-12ZG 10M 6-298BNS 303-12ZG-2187 6-298BNS 303-12ZG-2187 5M 6-298BP 8 2-109BP 10 2-108, 2-109BP 11N 2-108, 2-109BP 11S 2-108, 2-109BP 12N 2-108, 2-109BP 12S 2-108, 2-109BP 15 2-108, 2-109BP 20 2-108, 2-109BP 20N 2-108, 2-109BP 20S 2-108, 2-109BP 21N 2-108BP 21S 2-108BP 22NS 2-108BP 31 2-108, 2-109BP 31N 2-108, 2-109BP 31S 2-108, 2-109BP 34 2-108, 2-109BPS 16 6-294BPS 33 6-295BPS 33-2326 6-295BPS 40S-1 6-299BPS 40S-1-C 6-299BPS 40S-2 6-299BPS 40S-2-C 6-299BPS 250 6-296BPS 260-1 6-297BPS 260-2 6-297BPS 300 6-298BPS 303 6-298BPS 303 SS* 6-298BQ2320-9R-EX2 7-387BT7052S 4-226BT7822S 4-226BT7850-20S 4-226BT8432S 4-226BX4 14-639BX4-CA 14-639
CC06 2-122C07 2-122C10 2-122C19 2-122C48CB003 4-180C48CB103 4-180C48CD002 4-180C48CD012 4-180C48CD102 4-180C48CD112 4-180C48CS003 4-180C48CS013 4-180C48CS103 4-180C48CS113 4-180C48TD002 1-36C48TD012 1-36C48TD102 1-36C48TD112 1-36C48TS003 1-36C48TS013 1-36C48TS103 1-36C48TS113 1-36C110-2 2-67, 2-68C192PF8 15-666C695CHS012 7-379CA4-01 14-638CA4-04E 14-638CA4-04M 14-638CA4-10 14-638CA4-13M 14-638CA4-22E 14-638CA4-22M 14-638CA4-22U 14-638CA4-31E 14-638CA4-31M 14-638CA4-31U 14-638CA4-40E 14-638CA4-40U 14-638CA 501 14-635CA 504 E 14-635CA 510 14-635CA 522 E 14-635CA 522 M 14-635CA 531 E 14-635CA 531 M 14-635CA 531 U 14-635CA 540 E 14-635CA 540 U 14-635CAL4-11 14-638CAL 511 14-635CAL 511B 14-635CAL 1811 14-635CAL 1811 B 14-635CAT4-11E 14-638CAT4-11M 14-638CAT4-11U 14-638CAT5E-M12-M12-X 10-474, 10-475CAT5E-M12-RJ45-X 10-474, 10-475CAT5E-M12-X 10-474, 10-475CAT5E-RM12-M12-X 10-474, 10-475CAT5E-RM12-RJ45-X 10-474, 10-475CAT5E-RM12-RM12-X 10-474, 10-475CAT5E-RM12-X 10-474, 10-475CBLADK76 8-415CBLADKXX 8-415CBLPFM00 4-227CBLPRO4K 8-415CBLPRO7K 8-415CBLPROG0 7-401, 8-411, 8-412CBLUSB00 4-225, 7-401, 8-411, 8-412, 11-493, 11-494, 11-495, 11-496CBLUSB01 1-36, 1-43, 4-184, 4-186, 4-189, 4-191, 4-197, 4-203, 4-205, 4-210, 4-212, 4-216, 4-218, 4-221CBLUSB4K 8-415CBLUSB7K 8-415CBLxxxxx 4-225, 7-401, 7-403, 8-411, 8-412, 8-415, 11-493, 11-494, 11-495, 11-496CC4-01 14-638CC4-10 14-638CD5.121 3-144CD5.241 3-144CD5.241-L1 3-144CD5.241-S1 3-144CD5.242 3-144CD5.243 3-144CEIA-078 16-723CEIA-158 16-723CEIA-318 16-723CLB-FF-10 16-713CLB-FF-18 16-713CLB-FF-36 16-714
CLB-FM-10 16-713CLB-FM-18 16-713CLB-FM-36 16-714CLB-MF-10 16-705, 16-713CLB-MF-18 16-713CLB-MF-36 16-714CLF-FF-10 16-713CLF-FF-18 16-713CLF-FF-36 16-714CN-24A-C2 2-67, 2-72, 2-76CN-24A-C5 2-67, 2-72, 2-76CN-24AL-C2 2-67, 2-72, 2-76CN-24AL-C5 2-67, 2-72, 2-76CN-24B-C2 2-80CN-24B-C5 2-80CN-24BL-C2 2-80CN-24BL-C5 2-80CN-24-C2 2-74CN-24-C5 2-74CN-24C-C2 2-66, 2-70, 2-75, 2-93, 2-100CN-24C-C5 2-66, 2-70, 2-75, 2-93, 2-100CN-24CL-C2 2-66, 2-70, 2-75, 2-93, 2-100CN-24CL-C5 2-66, 2-70, 2-75, 2-93, 2-100CN-24L-C2 2-74CN-24L-C5 2-74CN-71-C2 2-78CN-71-C5 2-78CN-72-C2 2-78CN-72-C5 2-78CN-73-C2 2-78CN-73-C5 2-78CN-74-C2 2-78CN-74-C5 2-78CN-FF-90-3 16-718CN-FF-90-6 16-720CN-FF-230-3 16-718CN-FF-230-6 16-720CN-FF-350-3 16-718CN-FF-350-6 16-720CN-FF-600-3 16-719CN-FF-600-6 16-721CN-FF-1000-3 16-719CN-FF-1000-6 16-721CN-MF-90-3 16-718CN-MF-90-6 16-720CN-MF-230-3 16-718CN-MF-230-6 16-720CN-MF-350-3 16-718CN-MF-350-6 16-720CN-MF-600-3 16-719CN-MF-600-6 16-721CN-MF-1000-3 16-719CN-MF-1000-6 16-721CPA66 2-122CPA106 2-122CPA1010 2-122CPA1212 2-122CPAS6 2-122CPASS 2-122CPS20.121 3-131CPS20.241 3-131CPS20.241-D1 3-144CPS20.481 3-131CPS20.481-D1 3-144CS1 15-668CS1L 15-668CS1S 15-668CS2SL 15-668CS3.241 3-131CS4 15-668CS4S 15-668CS5.241 3-131CS8 15-668CS8S 15-668CS10.241 3-131CS10.242 3-131CS10.481 3-131CS12S 15-668CSBASE00 7-403CSBUNG00 7-403CSDIO14R 4-225, 7-402CSDIO14S 4-225, 7-402CSINI8L0 4-225, 7-402CSINI800 4-225, 7-402CSINV8L0 4-225, 7-402CSINV800 4-225, 7-402CSMSTRGT 7-401CSMSTRSX 7-401CSMSTRV2 7-401CSMSTRZR 7-401CSOUT400 4-225, 7-403CSPID1R0 4-225, 7-402CSPID1RA 4-225, 7-402CSPID1RM 7-402
769
Product Code Index
CSPID1S0 4-225, 7-402CSPID1SA 4-225, 7-402CSPID1SM 7-402CSPID1TA 4-225, 7-402CSPID2R0 4-225, 7-402CSPID2RM 7-402CSPID2S0 4-225, 7-402CSPID2SM 7-402CSPID2T0 4-225, 7-402CSPID2TM 7-402CSRTD600 4-225, 7-402CSSG10RA 4-225, 7-403CSSG10SA 4-225, 7-403CSSG11RA 4-225, 7-403CSSG11SA 4-225, 7-403CSTC8IS0 7-402CSTC8000 4-225, 7-402CSTERM00 7-403CSTUB-D-FF-900 16-722CSTUB-D-FF-2400 16-722CSTUB-D-MF-900 16-722CSTUB-D-MF-2400 16-722CSTUB-N-FF-900 16-722CSTUB-N-FF-2400 16-722CSTUB-N-MF-900 16-722CSTUB-N-MF-2400 16-722CT5.121 3-133CT5.241 3-133CT10.241 3-133CT10.481 3-133CT005050 4-206CT020050 4-206CUB4CL 4-168CUB4CL10 4-187CUB4CL20 4-187CUB4I000 4-201CUB4I010 4-201CUB4I020 4-201CUB4L000 4-179CUB4L010 4-179CUB4L020 4-179CUB4L800 4-179CUB4L810 4-179CUB4L820 4-179CUB4LP00 4-187CUB4LP40 4-187CUB4V000 4-208CUB4V010 4-208CUB4V020 4-208CUB5B000 4-184CUB5COM1 1-36, 1-43, 4-184, 4-189, 4-203, 4-210, 4-216CUB5COM2 1-36, 1-43, 4-184, 4-189, 4-203, 4-210, 4-216CUB5IB00 4-203CUB5IR00 4-203CUB5PB00 4-189CUB5PR00 4-189CUB5R000 4-184CUB5RLY0 1-36, 1-43, 4-184, 4-189, 4-203, 4-210, 4-216CUB5RTB0 4-216CUB5RTR0 4-216CUB5SNK0 1-36, 1-43, 4-184, 4-189, 4-203, 4-210, 4-216CUB5TB00 1-36, 1-43CUB5TCB0 4-216CUB5TCR0 4-216CUB5TR00 1-36, 1-43CUB5USB0 1-36, 1-43, 4-184, 4-189, 4-203, 4-210, 4-216CUB5VB00 4-210CUB5VR00 4-210CUB7CCG0 4-178CUB7CCR0 4-178CUB7CCS0 4-178CUB7CVG0 4-178CUB7CVR0 4-178CUB7CVS0 4-178CUB7TCG0 1-43CUB7TCR0 1-43CUB7TCS0 1-43CUB7TVG0 1-43CUB7TVR0 1-43CUB7TVS0 1-43CV77U033A12 13-601CV 77U034A15-* 13-600CV77U036A15-* 13-600CV 77U031615-* 13-600CX-411 2-76CX-411-P 2-76CX-411-P-Z 2-76CX-411-Z 2-76CX-413 2-76CX-413-P 2-76CX-413-P-Z 2-76
CX-413-Z 2-76CX-422 2-72CX-422-P 2-72CX-422-P-Z 2-72CX-422-Z 2-72CX-423 2-72CX-423-P 2-72CX-423-P-Z 2-72CX-423-Z 2-72CX-441 2-72CX-441-P 2-72CX-441-P-Z 2-72CX-441-Z 2-72CX-442 2-72CX-442-P 2-72CX-442-P-Z 2-72CX-442-Z 2-72CX-443 2-72CX-443-P 2-72CX-443-P-Z 2-72CX-443-Z 2-72CX-444 2-72CX-444-P 2-72CX-444-P-Z 2-72CX-444-Z 2-72CX-481 2-67CX-481-P 2-67CX-481-P-Z 2-67CX-481-Z 2-67CX-482 2-67CX-482-P 2-67CX-482-P-Z 2-67CX-482-Z 2-67CX-483 2-67CX-483-P 2-67CX-483-P-Z 2-67CX-483-Z 2-67CX-491 2-67CX-491-P 2-67CX-491-P-Z 2-67CX-491-Z 2-67CX-493 2-67CX-493-P 2-67CX-493-P-Z 2-67CX-493-Z 2-67CY-111A 2-75CY-111A-P 2-75CY-111A-P-Z 2-75CY-111A-Z 2-75CY-111B 2-75CY-111B-P 2-75CY-111B-P-Z 2-75CY-111B-Z 2-75CY-111VA 2-75CY-111VA-P 2-75CY-111VA-P-Z 2-75CY-111VA-Z 2-75CY-111VB 2-75CY-111VB-P 2-75CY-111VB-Z 2-75CY-121A 2-70CY-121A-P 2-70CY-121A-P-Z 2-70CY-121A-Z 2-70CY-121B 2-70CY-121B-P 2-70CY-121B-P-Z 2-70CY-121B-Z 2-70CY-121VA 2-70CY-121VA-P 2-70CY-121VA-P-Z 2-70CY-121VA-Z 2-70CY-121VB 2-70CY-121VB-P 2-70CY-121VB-P-Z 2-70CY-121VB-Z 2-70CY-122A 2-70CY-122A-P 2-70CY-122A-P-Z 2-70CY-122A-Z 2-70CY-122B 2-70CY-122B-P 2-70CY-122B-P-Z 2-70CY-122B-Z 2-70CY-122VA 2-70CY-122VA-P 2-70CY-122VA-P-Z 2-70CY-122VA-Z 2-70CY-122VB 2-70CY-122VB-P 2-70CY-122VB-P-Z 2-70CY-122VB-Z 2-70CY-191A-P-Y 2-66CY-191A-P-Z-Y 2-66CY-191A-Y 2-66CY-191A-Z-Y 2-66
CY-191B-P-Y 2-66CY-191B-P-Z-Y 2-66CY-191B-Y 2-66CY-191B-Z-Y 2-66CY-191VA-P-Y 2-66CY-191VA-P-Z-Y 2-66CY-191VA-Y 2-66CY-191VA-Z-Y 2-66CY-191VB-P-Y 2-66CY-191VB-P-Z-Y 2-66CY-191VB-Y 2-66CY-191VB-Z-Y 2-66CY-192A-P-Y 2-66CY-192A-P-Z-Y 2-66CY-192A-Y 2-66CY-192A-Z-Y 2-66CY-192B-P-Y 2-66CY-192B-P-Z-Y 2-66CY-192B-Y 2-66CY-192B-Z-Y 2-66CY-192VA-P-Y 2-66CY-192VA-P-Z-Y 2-66CY-192VA-Y 2-66CY-192VA-Z-Y 2-66CY-192VB-P-Y 2-66CY-192VB-P-Z-Y 2-66CY-192VB-Y 2-66CY-192VB-Z-Y 2-66
dDB4* 17-761DB9-RS23 16-705DB9-RS232 16-705, 16-711DB9-RS485 16-705, 16-711DB10/6* 17-761DB 25 25 14-640DB 25 32 14-640DB25-RS232 16-705, 16-711DB42 14-641DB 80 14-640DB 200 14-640DC25 2-123DC425 2-123DG10/5* 17-761DG10/8* 17-761DG10/10* 17-761DKH101UP 4-226DM01 5-276DM 10 5-277DMD 331 5-270DMD 831 5-271DMK 331 5-235, 5-259DMK 331P 5-235, 5-262DMK 351 5-235, 5-260DMK 351P 5-235, 5-263DMP 331 5-235, 5-253DMP 331P 5-235, 5-261DMP 333 5-235, 5-254DMP 334 5-235, 5-257DMP 335 5-235, 5-255DMP 339 5-235, 5-256DMP 343 5-235, 5-252DMP 457 5-235, 5-258DMS132-G 14-646DMS132-Y 14-646DP5D0000 4-202, 4-209DP5D0010 4-202, 4-209DP5P0000 4-188DP5P0010 4-188DP5T0000 4-215DP5T0010 4-215DPS 300 5-272DR25A-** 14-641DR12849 12-540DRA 26-30 xxx 14-648DRA 30-30 xxx 14-648DRA 40-30 xxx 14-648DRA 50-30 xxx 14-648DRA 63-30 xxx 14-648DRA 75-30 xxx 14-648DRA 95-30 xxx 14-648DRE500-** 14-641DRRJ11T6 4-225, 7-403, 8-411, 8-413, 11-493, 11-494, 11-495, 11-496DRRJ45T8 4-225, 7-403, 8-411, 8-413, 11-493, 11-494, 11-495, 11-496DRTA42-** 14-641DRTA110-** 14-641DS 200 5-236, 5-278DS 201 5-236, 5-279DS 201BS-C6 13-572DS 201BS-C10 13-572DS 201BS-C13 13-572DS 201BS-C16 13-572
DS 201BS-C20 13-572DS 201BS-C25 13-572DS 201BS-C32 13-572DS 201BS-C40 13-572DS 217 5-236, 5-282DS 230 5-236, 5-284DS271C6 13-573DS271C6/0.01 13-573DS271C10 13-573DS271C10/0.01 13-573DS271C16 13-573DS271C16/0.01 13-573DS271C20 13-573DS271C20/0.01 13-573DS271C25 13-573DS271C25/0.01 13-573DS271C32 13-573DS271C32/0.01 13-573DS271C40 13-573DS271C40/0.01 13-573DS 400 5-236, 5-280DS 400P 5-236, 5-283DS 401 5-236, 5-281DSN 201C6 13-572DSN 201C10 13-572DSN 201C13 13-572DSN 201C16 13-572DSN 201C20 13-572DSN 201C25 13-572DSN 201C32 13-572DSPGT000 11-495DSPGT001 11-495DSPLE000 11-493DSPSX000 11-494DSPSX001 11-494DSPZR000 11-496DT800000 4-182DT800010 4-182DT800020 4-182DYA 9-30 xxx 14-648DYA 12-30 xxx 14-648DYA 16-30 xxx 14-648
eE2-8AO20M-D 7-395E2-10RTD-D 7-395E2-16AI-8AO-D 7-395E2-16AI20M-D 7-395E2-16DI24-D 7-395E2-16DIAC-D 7-395E2-16DO24-D 7-395E2-16ISO20M-D 7-395E2-16ISOTC-D 7-395E2-32AI10V-D 7-395E2-32AI20M-D 7-395E2-32DI24-D 7-395E2-32DO24-D 7-395E2-MIX24880-D 7-395E2-MIX24882-D 7-395EB-8AO20M-D 7-395EB-10RTD-D 7-395EB-16AI-8AO-D 7-395EB-16AI20M-D 7-395EB-16DI24-D 7-395EB-16DO24-D 7-395EB-16ISO20M-D 7-395EB-16ISOTC-D 7-395EB-32AI10V-D 7-395EB-32AI20M-D 7-395EB-32DI24-D 7-395EB-32DO24-D 7-395EB-GT-8ES-1EP 10-473EB-MIX24880-D 7-395EB-MIX24882-D 7-395EB-PSE-24V-1A 10-479EB-PSE-48V-2A 10-479EC20-90 16-732EC20-230 16-732EC20-350 16-732EC20-600 16-732EC20-1000 16-732EC100-230 16-733EC100-350 16-733EC100-500 16-733EC100-1000 16-733EDAN 6 12-531EDL BL 12-515EDL GB 12-515EDL GN 12-515EDLR BL 12-515EDLR GB 12-515EDLR GN 12-515EDLR RT 12-515
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
4-204, 4-205, 4-206, 4-207, 4-208, 4-209, 4-210, 4-211, 4-212, 4-213, 4-214, 4-215, 4-216, 4-217, 4-218, 4-219, 4-220, 4-221ENC5C000 4-179, 4-181, 4-182, 4-183, 4-185, 4-186, 4-187, 4-188, 4-189, 4-190, 4-191, 4-197, 4-201, 4-202, 4-203, 4-204, 4-205, 4-206, 4-207, 4-208, 4-209, 4-210, 4-211, 4-212, 4-213, 4-214, 4-215, 4-216, 4-217, 4-218, 4-219, 4-220, 4-221ENC8A000 1-36, 1-43, 4-179, 4-182, 4-184, 4-187, 4-189, 4-201, 4-203, 4-208, 4-210, 4-216ENC8B000 1-36, 1-43, 4-179, 4-182, 4-184, 4-187, 4-189, 4-201, 4-203, 4-208, 4-210, 4-216ENC11A00 1-36, 4-180, 4-193, 4-194, 4-195, 4-196ENC11B00 1-36, 4-180, 4-193, 4-194, 4-195, 4-196ENC13000 1-43, 4-178ENC90000 4-231EPAX0500 4-230EPAX0600 4-230EPAXENSH 4-231EPAXPGM0 4-231EQ-34 2-74EQ-34-J 2-74EQ-34-PN 2-74EQ-34-PN-J 2-74EQ-34W 2-74EQ-501 2-74, 2-85EQ-501T 2-74ESERV-11T 11-498ESERV-11T-ST 11-498ESERV-12T 11-498ESERV-12T-ST 11-498ESERV-M12T 11-499ESERV-M12T-ST 11-499ESS21S1 12-529ESS21S2 12-529ESS21S12 12-529ESS32S1 12-529ESS32S2 12-529ESS32S3 12-529ESS32S123 12-529EST21S1 12-529ESTS32S2 12-529ET-5ES-IP67-E 10-473ET-8EG-MIL-1 10-473ET-8ES-MIL-1 10-473ET-8MG-MIL-1 10-473ET-8MS-MIL-1 10-473EWS21 12-525EWS21.1 12-525EWS32 12-525EWS32.1 12-525EWSE3K 12-527EWSE4K 12-527EWSE5K 12-527EWSE6K 12-527EWSE7K 12-527EWSE8K 12-527EWSE9K 12-527EWSE10K 12-527EWSE11K 12-527EWSE12K 12-527EWT21 12-525EWT21.1 12-525EWT32 12-525EWT32.1 12-525EWTS32 12-525EWTS32.1 12-525EWTS321 12-525EWTS321.1 12-525EX-14A 2-71EX-14A-PN 2-71EX-14B 2-71EX-14B-PN 2-71EX-15 2-76EX-17 2-76EX-31A 2-76EX-31A-PN 2-76EX-31B 2-76EX-31B-PN 2-76EX-32A 2-71EX-32A-PN 2-71EX-32B 2-71EX-32B-PN 2-71EX-AZ 16ZVK-3D 6-289EX-L211 2-81, 2-90EX-L211-P 2-81EX-L212 2-81, 2-90EX-L212-P 2-81EX-L221 2-81, 2-90EX-L221-P 2-81EX-L291 2-81, 2-90EX-L291-P 2-81
FF2CA1 13-574F2CA2 13-574F202 25 13-571F202 25/0.1 13-571F202 25/0.3 13-571F202 40 13-571F202 40/0.1 13-571F202 40/0.3 13-571F202 63 13-571F202 63/0.1 13-571F202 63/0.3 13-571F202PVB 25 13-572F202PVB 25/0.3 13-572F202PVB 63 13-572F202PVB 63/0.3 13-572F204 25 13-571F204 25/0.1 13-571F204 25/0.3 13-571F204 40 13-571F204 40/0.1 13-571F204 40/0.3 13-571F204 63 13-571F204 63/0.1 13-571F204 63/0.3 13-571FCAN-01 14-610FCOPPER-SFP-100 10-467FD-31 2-79FD-42G 2-79FD-61 2-79FD-H35-M2 2-79FDNA-01 14-610FD-R60 2-79FEMTO 15-654FENA-01 14-610FH202 25 13-571FH202 25/0.1 13-571FH202 25/0.3 13-571FH202 40 13-571FH202 40/0.1 13-571FH202 40/0.3 13-571FH202 63 13-571FH202 63/0.1 13-571FH202 63/0.3 13-571FH204 25 13-571FH204 25/0.1 13-571FH204 25/0.3 13-571FH204 40 13-571FH204 40/0.1 13-571FH204 40/0.3 13-571FH204 63 13-571FH204 63/0.1 13-571FH204 63/0.3 13-571Flash 96H 15-661FMBA-01 14-610FMFIBER-SFP-4K 10-465, 10-467, 10-468FP0-A04I 7-346, 7-351FP0-A04V 7-346, 7-351FP0-A21-A 7-346, 7-351FP0-A80-A 7-346, 7-351FP0-CABLE-9N 7-346, 7-352FP0-E32RS 7-346, 7-351FP0-PSA4 7-346FP0R-C14CRS 7-345FP0R-C14MRS 7-345FP0R-C14RS 7-345FP0R-C16CP 7-345FP0R-C16CT 7-345FP0R-C16MP 7-345FP0R-C16MT 7-345FP0R-C16P 7-345FP0R-C16T 7-345FP0R-C32CP 7-345FP0R-C32CT 7-345FP0R-C32MP 7-345FP0R-C32MT 7-345FP0R-C32P 7-345FP0R-C32T 7-345FP0R-CABLE-USB 7-346FP0R-E8RS 7-346, 7-351FP0R-E8X 7-346, 7-351FP0R-E8YP 7-346, 7-351FP0R-E8YRS 7-346, 7-351FP0R-E8YT 7-346, 7-351FP0R-E16P 7-346, 7-351FP0R-E16RS 7-346, 7-351FP0R-E16T 7-346, 7-351FP0R-E16X 7-346, 7-351FP0R-E16YP 7-346, 7-351FP0R-E16YT 7-346, 7-351FP0R-E32P 7-346, 7-351FP0R-E32T 7-346, 7-351FP0R-F32CP 7-345FP0R-F32CT 7-345
FP0R-F32MP 7-345FP0R-F32MT 7-345FP0R-T32CP 7-345FP0R-T32CT 7-345FP0R-T32MP 7-345FP0R-T32MT 7-345FP0-RTD6 7-346, 7-351FP0-TC4 7-346, 7-351FP0-TC8 7-346, 7-351FPBA-01 14-610FPWINPROFEN6 7-346, 7-352, 7-365FPWINPROSEN6 7-346, 7-352, 7-365FSFIBER-SFP-30K 10-465, 10-467, 10-468FSFIBER-SFP-60K 10-465, 10-467, 10-468FSFIBER-SFP-100K 10-465, 10-467, 10-468FT-31 2-79FT-42 2-79FT-140 2-79FT-H35-M2 2-79FT-R40 2-79FWS 1205 C 6-322FX-101-CC2 2-78FX-101P-CC2 2-78FX-501 2-78FX-501P 2-78FX-502 2-78FX-502P 2-78FX-505-C2 2-78FX-505P-C2 2-78FX-LE1 2-79FX-MR2 2-79
GG3AD0607 8-411G3AD0807 8-411G3AD1009 8-411G3AD1010 8-411G3AD1012 8-411G3AD1515 8-411G3BR06A0 8-413G3BR08A0 8-413G3BR10C1 8-413G3BR10S1 8-413G3CF001G 4-225, 7-403, 8-411, 8-413, 11-493, 11-494, 11-495, 11-496G3CF002G 4-225, 7-403, 8-411, 8-413, 11-494, 11-495, 11-496G3CN0000 8-412G3DN0000 8-412G3ENET00 8-412G3FILM4K 8-415G3FILM06 8-411, 8-413G3FILM6K 8-415G3FILM08 8-413G3FILM10 8-413G3FILM15 8-413G3GSM000 8-412G3PBDP00 8-412G3RS0000 8-412G4 1052 1-23G07C0000 8-410G07S0000 8-410G09C0000 8-410G09C1000 8-410G10C0000 8-410G10C1000 8-410G10R0000 8-410G10R1000 8-410G10S0000 8-410G10S1000 8-410G12C0000 8-410G12C1100 8-410G15C0000 8-410G15C1100 8-410G303M000 8-413G303S000 8-413G304K200 8-415G306A000 8-413G306M000 8-413G306MS00 8-413G307K200 8-415G308A210 8-413G308A230 8-413G308C100 8-413G310C210 8-413G310C230 8-413G310R210 8-413G310R230 8-413G310S210 8-413G310S230 8-413G315C210 8-413
EDLR SW 12-515EDL RT 12-515EDLR WS 12-515EDL WS 12-515EDLXR172 15-667EDLXR175 15-667EDP55 BL 12-514EDP55 GB 12-514EDP55 GN 12-514EDP55 RT 12-514EDP55 SW 12-514EDP55 WS 12-514EDRR 40 RT 12-522EDRR 50 RT 12-522EDT BL 12-514EDT GB 12-514EDT GN 12-514EDTR BL 12-514EDTR GB 12-514EDTR GN 12-514EDTR RT 12-514EDTR SW 12-514EDT RT 12-514EDTR WS 12-514EDT SW 12-514EDT WS 12-514EF 03.1 12-516, 12-517EF03.1 12-514, 12-516, 12-525, 12-526, 12-529, 12-530EF 10.1 12-516, 12-517EF10.1 12-514, 12-525, 12-526, 12-529, 12-530EF19-0.32 14-641EF19-1.0 14-641EF19-2.7 14-641EF19-6.3 14-641EF19-18.9 14-641EF 033.1 12-516, 12-517EF033.1 12-514, 12-525, 12-526, 12-529, 12-530EF45-30 14-641EF45-45 14-641EF 103.1 12-516, 12-517EF103.1 12-514, 12-525, 12-526, 12-529, 12-530EF 220.1 12-516, 12-517, 12-522EF220.1 12-514, 12-525, 12-526, 12-529, 12-530EF 301.1 12-516, 12-517EF 303.1 12-516, 12-517, 12-522EF 303S.1 12-516, 12-517EFR 12-522EKIT-012 16-734EKIT-038 16-734EKIT-078 16-734EKIT-158 16-734EKIT-318 16-734EKS 12-530EL 12-531EL212F-AC-V1 10-467EL212F-DC-V1 10-467EL228-A0-1 10-468EL228-AA-1 10-468EL228-D0-1 10-468EL228-DD-1 10-468EL326-AA-1 10-472EL326-AO-1 10-472EL326-DD-1 10-472EL326-DO-1 10-472ELDE.N BL 24 12-517ELDE.N BL 230 12-517ELDE.N GB 24 12-517ELDE.N GB 230 12-517ELDE.N GN 24 12-517ELDE.N GN 230 12-517ELDE.N RT 24 12-517ELDE.N RT 230 12-517ELDE.N WS 24 12-517ELDE.N WS 230 12-517ELE 12-515, 12-519, 12-520ELE 230 12-515, 12-519, 12-520E-LR-4 12-536EM132AU 15-659EM133 15-659EM133AR 15-659EM133AU 15-659EM720 15-665EM720T 15-665EMES 12-531EML BL 12-519EML GB 12-519EML GN 12-519EML RT 12-519EML WS 12-519ENC5B000 4-179, 4-181, 4-182, 4-183, 4-185, 4-186, 4-187, 4-188, 4-189, 4-190, 4-191, 4-192, 4-197, 4-201, 4-202, 4-203,
771
Product Code Index
G315C230 8-413GD18/GV18/73/120 2-75GD18/GV18/115/120 2-75GLV18-8-450/73/120 2-71GLV18-8-450/115/120 2-71GLV18-55/73/120 2-67GLV18-55/115/120 2-67GMDIOR00 8-410GMDIOS00 8-410GMFIBER-SFP-2K 10-465, 10-467, 10-468, 10-472GMFIBER-SFP-500 10-465, 10-467, 10-468, 10-472GMINI800 8-410GMINV800 8-410GMOUT400 8-410GMP1RA00 8-410GMP1RM00 8-410GMP1SA00 8-410GMP1SM00 8-410GMP2R000 8-410GMP2RM00 8-410GMP2S000 8-410GMP2SM00 8-410GMRTD600 8-410GMTC8000 8-410GMUIN400 8-410GSFIBER-SFP-10K 10-465, 10-467, 10-468, 10-472GSFIBER-SFP-30K 10-465, 10-467, 10-468, 10-472GSFIBER-SFP-50K 10-465, 10-467, 10-468, 10-472GSFIBER-SFP-80K 10-465, 10-467, 10-468, 10-472GX-F8A 2-101GX-F8A-P 2-101GX-F8B 2-101GX-F8B-P 2-101GX-F12A-C5 2-101GX-F12A-P-C5 2-101GX-F12B-C5 2-101GX-F12B-P-C5 2-101GX-H8A 2-101GX-H8A-P 2-101GX-H8B 2-101GX-H8B-P 2-101GX-H12A-C5 2-101GX-H12A-P-C5 2-101GX-H12B-C5 2-101GX-H12B-P-C5 2-101GX-M8A 2-92GX-M8A-P 2-92GX-M8A-P-Z 2-92GX-M8A-U 2-100GX-M8A-U-J 2-100GX-M8A-Z 2-92GX-M8B 2-92GX-M8B-P 2-92GX-M8B-P-Z 2-92GX-M8B-U 2-100GX-M8B-U-J 2-100GX-M8B-Z 2-92GX-M12A 2-92GX-M12A-P 2-92GX-M12A-P-Z 2-92GX-M12A-U 2-100GX-M12A-U-Z 2-100GX-M12A-Z 2-92GX-M12B 2-92GX-M12B-P 2-92GX-M12B-P-Z 2-92GX-M12B-U 2-100GX-M12B-U-Z 2-100GX-M12B-Z 2-92GX-M18A 2-92GX-M18A-P 2-92GX-M18A-P-Z 2-92GX-M18A-U 2-100GX-M18A-U-Z 2-100GX-M18A-Z 2-92GX-M18B 2-92GX-M18B-P 2-92GX-M18B-P-Z 2-92GX-M18B-U 2-100GX-M18B-U-Z 2-100GX-M18B-Z 2-92GX-M30A 2-92GX-M30A-P 2-92GX-M30A-P-Z 2-92GX-M30A-U 2-100GX-M30A-U-Z 2-100GX-M30A-Z 2-92GX-M30B 2-92GX-M30B-P 2-92GX-M30B-P-Z 2-92
GX-M30B-U 2-100GX-M30B-U-Z 2-100GX-M30B-Z 2-92GX-MK12A 2-92GX-MK12A-P 2-92GX-MK12A-P-Z 2-92GX-MK12A-Z 2-92GX-MK12B 2-92GX-MK12B-P 2-92GX-MK12B-P-Z 2-92GX-MK12B-Z 2-92GX-MK18A 2-92GX-MK18A-P 2-92GX-MK18A-P-Z 2-92GX-MK18A-Z 2-92GX-MK18B 2-92GX-MK18B-P 2-92GX-MK18B-P-Z 2-92GX-MK18B-Z 2-92GX-MK30A 2-92GX-MK30A-P 2-92GX-MK30A-P-Z 2-92GX-MK30A-Z 2-92GX-MK30B 2-92GX-MK30B-P 2-92GX-MK30B-P-Z 2-92GX-MK30B-Z 2-92GX-ML8A-U 2-100GX-ML8A-U-J 2-100GX-ML8B-U 2-100GX-ML8B-U-J 2-100GX-ML12A-U 2-100GX-ML12A-U-Z 2-100GX-ML12B-U 2-100GX-ML12B-U-Z 2-100GX-ML18A-U 2-100GX-ML18A-U-Z 2-100GX-ML18B-U 2-100GX-ML18B-U-Z 2-100GX-ML30A-U 2-100GX-ML30A-U-Z 2-100GX-ML30B-U 2-100GX-ML30B-U-Z 2-100GZM2 1-23GZM4 1-23GZM80 1-20, 1-21GZM80-0041 1-20GZM92 1-20, 1-21GZT2 1-23GZT4 1-23GZT4-0035 1-23GZT4-0040 1-23GZT80 1-20, 1-21GZT80-0035 1-20, 1-21GZT80-0040 1-20, 1-21GZT92 1-20, 1-21
HH60 2-68, 2-69H221 15-675H321 15-675H421 15-675H600 15-676H608 15-676H900 15-676H908 15-676H921 15-675H923 15-675HE1AN-AC24V 1-28HE1AN-AC120V 1-28HE1AN-AC240V 1-28HE1AN-DC24V 1-28HE1AN-S-AC24V 1-28HE1AN-S-AC120V 1-28HE1AN-S-AC240V 1-28HE1AN-S-DC24V 1-28HE2AN-AC24V 1-28HE2AN-AC120V 1-28HE2AN-AC240V 1-28HE2AN-DC24V 1-28HE2AN-S-AC24V 1-28HE2AN-S-AC120V 1-28HE2AN-S-AC240V 1-28HE2AN-S-DC24V 1-28HE693SNPCBL 7-382HJ2-L-AC24V 1-26HJ2-L-AC120V 1-26HJ2-L-AC240V 1-26HJ2-L-DC24V 1-26HJ2-L-T-AC24V 1-26HJ2-L-T-AC120V 1-26HJ2-L-T-AC240V 1-26HJ2-L-T-DC24V 1-26
HJ2-SFD-S 1-26HJ4-L-AC24V 1-26HJ4-L-AC120V 1-26HJ4-L-AC240V 1-26HJ4-L-DC24V 1-26HJ4-L-T-AC24V 1-26HJ4-L-T-AC120V 1-26HJ4-L-T-AC240V 1-26HJ4-SFD-S 1-26HK4-11 14-644HK4-W 14-644HKS4-02 14-644HKS4-11 14-644HKS4-20 14-644HL2-L-AC24V 1-27HL2-L-AC120V 1-27HL2-L-AC240V 1-27HL2-L-DC24V 1-27HSG1-25-275 16-693HSG3-25-275 16-693HT-20 2-124HT-20C 2-125HT-20-X 2-124HTT-20 2-124
iIAMA0006 11-504IAMA3535 11-503IAMA6262 11-503IAMS0001 11-502, 11-506IAMS0010 11-502, 11-506IAMS0011 11-502, 11-506IB132-G 14-646IB132-Y 14-646IC200ACC003 7-371, 7-375IC200ACC414 7-368IC200ALG230 7-371IC200ALG240 7-371IC200ALG260 7-371IC200ALG261 7-371IC200ALG262 7-371IC200ALG263 7-371IC200ALG264 7-371IC200ALG265 7-371IC200ALG266 7-371IC200ALG320 7-371IC200ALG321 7-371IC200ALG322 7-371IC200ALG325 7-371IC200ALG326 7-371IC200ALG327 7-371IC200ALG331 7-371IC200ALG430 7-371IC200ALG431 7-371IC200ALG620 7-371IC200ALG630 7-371IC200BEM002 7-371IC200BEM103 7-371IC200BEM104 7-371IC200CBL001 7-371IC200CBL105 7-370IC200CBL110 7-370IC200CBL120 7-370IC200CBL230 7-370IC200CBL500 7-368IC200CBL600 7-371IC200CBL601 7-371IC200CBL602 7-371IC200CHS001 7-369IC200CHS002 7-369IC200CHS003 7-369IC200CHS005 7-369IC200CHS006 7-371IC200CHS011 7-369IC200CHS012 7-369IC200CHS014 7-369IC200CHS015 7-369IC200CHS022 7-369IC200CHS025 7-369IC200CHS101 7-369IC200CHS102 7-369IC200CHS111 7-369IC200CHS112 7-369IC200CHS211 7-369IC200CHS212 7-369IC200CMM020 7-371IC200CPU001 7-369IC200CPU002 7-369IC200CPU005 7-369IC200CPUE05 7-369IC200DBI001 7-371IC200EBI001 7-371IC200ERM001 7-371
IC200ERM002 7-371IC200ETM001 7-371IC200GBI001 7-371IC200MDD840 7-370IC200MDD841 7-370IC200MDD842 7-370IC200MDD843 7-370IC200MDD844 7-370IC200MDD845 7-370IC200MDD846 7-370IC200MDD847 7-370IC200MDD848 7-370IC200MDD849 7-370IC200MDD850 7-370IC200MDD851 7-370IC200MDL140 7-370IC200MDL141 7-370IC200MDL143 7-370IC200MDL144 7-370IC200MDL240 7-370IC200MDL241 7-370IC200MDL243 7-370IC200MDL244 7-370IC200MDL329 7-370IC200MDL330 7-370IC200MDL331 7-370IC200MDL631 7-370IC200MDL632 7-370IC200MDL635 7-370IC200MDL636 7-370IC200MDL640 7-370IC200MDL643 7-370IC200MDL644 7-370IC200MDL650 7-370IC200MDL730 7-370IC200MDL740 7-370IC200MDL741 7-370IC200MDL742 7-370IC200MDL743 7-370IC200MDL744 7-370IC200MDL750 7-370IC200MDL930 7-370IC200MDL940 7-370IC200NAL110 7-366IC200NAL211 7-366IC200NDD010 7-366IC200NDD101 7-366IC200NDR001 7-366IC200NDR010 7-366IC200PBI001 7-371IC200PNS001 7-371IC200PNS002 7-371IC200PWB001 7-369IC200PWR001 7-369IC200PWR002 7-369IC200PWR101 7-369IC200PWR102 7-369IC200PWR201 7-369IC200PWR202 7-369IC200SET001 7-368IC200UAA003 7-367IC200UAA007 7-367IC200UAL004 7-367IC200UAL005 7-367IC200UAL006 7-367IC200UAR014 7-367IC200UAR028 7-367IC200UDD020 7-367IC200UDD040 7-367IC200UDD104 7-367IC200UDD110 7-367IC200UDD112 7-367IC200UDD120 7-367IC200UDD140 7-367IC200UDD212 7-367IC200UDD220 7-367IC200UDR001 7-367IC200UDR002 7-367IC200UDR003 7-367IC200UDR005 7-367IC200UDR006 7-367IC200UDR010 7-367IC200UDR020 7-367IC200UDR040 7-367IC200UDR120 7-367IC200UDR140 7-367IC200UDR228 7-367IC200UDR440 7-367IC200UEC008 7-368IC200UEC108 7-368IC200UEC208 7-368IC200UEI008 7-368IC200UEI016 7-368IC200UEM001 7-368IC200UEO008 7-368IC200UEO016 7-368
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
IC200UEO108 7-368IC200UEO116 7-368IC200UER008 7-368IC200UER016 7-368IC200UEX009 7-368IC200UEX010 7-368IC200UEX011 7-368IC200UEX012 7-368IC200UEX013 7-368IC200UEX014 7-368IC200UEX015 7-368IC200UEX122 7-368IC200UEX209 7-368IC200UEX210 7-368IC200UEX211 7-368IC200UEX212 7-368IC200UEX213 7-368IC200UEX214 7-368IC200UEX215 7-368IC200UEX222 7-368IC200UEX616 7-368IC200UEX624 7-368IC200UEX626 7-368IC200UEX636 7-368IC200UEX724 7-368IC200UEX726 7-368IC200UEX734 7-368IC200UEX736 7-368IC200UMB001 7-368IC200UMM002 7-367, 7-368IC200UMM102 7-367, 7-368IC200USB001 7-368IC200USB002 7-368IC200UUB001 7-368IC690ACC001 7-382IC690ACC901 7-382IC690CRG001 7-382IC690RBT001 7-382IC693ACC300 7-373IC693ACC301 7-375IC693ACC302 7-375, 7-382IC693ACC307 7-382IC693ACC310 7-375IC693ACC311 7-382IC693ACC329 7-375IC693ACC330 7-375IC693ACC331 7-375IC693ACC332 7-375IC693ACC333 7-375IC693ACC337 7-375IC693ACC341 7-373IC693ACC350 7-373IC693ALG220 7-374IC693ALG221 7-374IC693ALG222 7-374IC693ALG223 7-374IC693ALG390 7-374IC693ALG391 7-374IC693ALG392 7-374IC693ALG442 7-374IC693APU300 7-374IC693APU301 7-374IC693APU302 7-374IC693APU305 7-374, 7-381IC693BEM331 7-374IC693CBK001 7-375IC693CBK002 7-375IC693CBK003 7-375IC693CBK004 7-375IC693CBL300 7-375, 7-382IC693CBL301 7-375, 7-382IC693CBL302 7-375, 7-382IC693CBL312 7-375, 7-382IC693CBL313 7-375, 7-382IC693CBL314 7-375, 7-382IC693CBL327 7-375IC693CBL328 7-375IC693CBL329 7-375IC693CBL330 7-375IC693CBL331 7-375IC693CBL332 7-375IC693CBL333 7-375IC693CBL334 7-375IC693CHS391 7-372, 7-374IC693CHS392 7-372IC693CHS393 7-372IC693CHS397 7-372, 7-374IC693CHS398 7-372IC693CHS399 7-372IC693CMM302 7-374IC693CPU311 7-372IC693CPU313 7-372IC693CPU323 7-372IC693CPU350 7-372IC693CPU360 7-372IC693CPU363 7-372
IC693CPU366 7-372IC693CPU367 7-372IC693CPU370 7-372IC693CPU372 7-372IC693CPU374 Plus 7-372IC693DNM200 7-374IC693DNS201 7-374IC693DSM302 7-374IC693DSM314 7-374IC693DSM324 7-374IC693MAR590 7-373IC693MDL230 7-373IC693MDL231 7-373IC693MDL240 7-373IC693MDL241 7-373IC693MDL250 7-373IC693MDL260 7-373IC693MDL310 7-373IC693MDL330 7-373IC693MDL340 7-373IC693MDL350 7-373IC693MDL390 7-373IC693MDL632 7-373IC693MDL634 7-373IC693MDL645 7-373IC693MDL646 7-373IC693MDL648 7-373IC693MDL654 7-373IC693MDL655 7-373IC693MDL660 7-373IC693MDL730 7-373IC693MDL731 7-373IC693MDL732 7-373IC693MDL733 7-373IC693MDL734 7-373IC693MDL740 7-373IC693MDL741 7-373IC693MDL742 7-373IC693MDL748 7-373IC693MDL752 7-373IC693MDL753 7-373IC693MDL754 7-373IC693MDL760 7-374, 7-381IC693MDL916 7-373IC693MDL930 7-373IC693MDL931 7-373IC693MDL940 7-373IC693MDR390 7-373IC693NIU004 7-374, 7-381IC693PBM200 7-374IC693PBS201 7-374IC693PTM101 7-374, 7-381IC693PWR321 7-373IC693PWR322 7-373IC693PWR328 7-373, 7-379IC693PWR330 7-373IC693PWR331 7-373IC693PWR332 7-373, 7-379IC693TCM302 7-374, 7-381IC693TCM303 7-374, 7-381IC694ACC300 7-379IC694ACC310 7-382IC694ALG220 7-380IC694ALG221 7-380IC694ALG222 7-380IC694ALG223 7-380IC694ALG390 7-380IC694ALG391 7-380IC694ALG392 7-380IC694ALG442 7-380IC694APU300 7-381IC694BEM331 7-381IC694CHS392 7-379IC694CHS393 7-379IC694CHS398 7-379IC694CHS399 7-379IC694DNM200 7-381IC694DSM314 7-381IC694DSM324 7-381IC694MDL230 7-379IC694MDL231 7-379IC694MDL240 7-379IC694MDL241 7-379IC694MDL250 7-379IC694MDL260 7-379IC694MDL310 7-380IC694MDL330 7-380IC694MDL340 7-380IC694MDL350 7-380IC694MDL390 7-380IC694MDL632 7-379IC694MDL634 7-379IC694MDL645 7-379IC694MDL646 7-379IC694MDL654 7-379IC694MDL655 7-379
IC694MDL660 7-379IC694MDL732 7-380IC694MDL734 7-380IC694MDL740 7-380IC694MDL741 7-380IC694MDL742 7-380IC694MDL752 7-380IC694MDL753 7-380IC694MDL754 7-380IC694MDL916 7-380IC694MDL930 7-380IC694MDL931 7-380IC694MDL940 7-380IC694PWR321 7-379IC694PWR330 7-379IC694PWR331 7-379IC694TBB032 7-375, 7-382IC694TBB132 7-375, 7-382IC694TBS032 7-375, 7-382IC694TBS132 7-375, 7-382IC695ACC302 7-382IC695ACC400 7-382IC695ACC600 7-382IC695ALG106 7-380IC695ALG112 7-380IC695ALG306 7-380IC695ALG312 7-380IC695ALG508 7-380IC695ALG600 7-380IC695ALG608 7-380IC695ALG616 7-380IC695ALG626 7-380IC695ALG628 7-380IC695ALG704 7-380IC695ALG708 7-380IC695ALG728 7-380IC695ALG808 7-380IC695CBL001 7-382IC695CHS007 7-379IC695CHS016 7-379IC695CMM002 7-381IC695CMM004 7-381IC695CMX128 7-381IC695CPE305 7-378IC695CPE310 7-378IC695CPU315 7-378IC695CPU320 7-378IC695CRU320 7-378IC695CRU320QP 7-378IC695ETM001 7-381IC695FTB1B032 7-382IC695FTB1S032 7-382IC695HSC301 7-381IC695HSC308 7-381IC695LRE001 7-381IC695NIU001 7-381IC695NKT001 7-381IC695PBM300 7-381IC695PBS301 7-381IC695PMM335 7-381IC695PNC001 7-381IC695PNS001 7-381IC695PSA040 7-379IC695PSA140 7-379IC695PSD040 7-379IC695PSD140 7-379IC695RBK001 7-382IC695RMX128 7-381IC698ACC701 7-382IC754V*B06CTD 8-424IC754V*B06MTD 8-424IC754V*F08CTD 8-422IC754V*F12CTD 8-422IC754V*F15CTD 8-422IC754V*I06MTD 8-423IC754V*I06STD 8-423IC754V*I08CTD 8-423IC754V*I12CTD 8-423IC754V*I12MTD 8-423IC754V*L06CTD 8-422IC754V*L06MTD 8-422ICM50000 11-500ICM80000 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221ICRXIACCBPL 7-376ICRXIACCIDM01A 7-376ICRXIACCIFM01A 7-376ICRXICTL000A 7-376ICRXIFC0E111A 7-388ICRXIFC0P111A 7-388ICRXIFC7E111A 7-388ICRXIFC7P111A 7-388IFL 2-8M-10N 2-94IFL 2-8M-10P 2-94
IFL 2-12-01 2-99IFL 2-12-10 2-95, 2-99IFL 2-12-10N 2-94IFL 2-12-10P 2-94IFL 2-12-10STN 2-94IFL 2-12-10STP 2-94IFL 4-12-01 2-99IFL 4-12-10 2-95, 2-99IFL 4-12-10N 2-94IFL 4-12-10P 2-94IFL 4-12-10STN 2-94IFL 4-12-10STP 2-94IFL 5-18-01 2-99IFL 5-18-01A 2-99IFL 5-18-10 2-95, 2-99IFL 5-18-10A 2-99IFL 5-18-10N 2-94IFL 5-18-10P 2-94IFL 5-18-10STN 2-94IFL 5-18-10STP 2-94IFL 5-18L-11N 2-98IFL 5-18L-11P 2-98IFL 5-18L-11STN 2-98IFL 5-18L-11STP 2-98IFL 8-18-01 2-99IFL 8-18-10 2-95, 2-99IFL 8-18-10N 2-94IFL 8-18-10P 2-94IFL 8-18-10STN 2-94IFL 8-18-10STP 2-94IFL 8-18L-11N 2-98IFL 8-18L-11P 2-98IFL 8-18L-11STN 2-98IFL 8-18L-11STP 2-98IFL 10-30-01T 2-99IFL 10-30-10T 2-99IFL 10-30L-10/01N 2-94IFL 10-30L-10/01P 2-94IFL 10-30L-10TN 2-94IFL 10-30L-10TP 2-94IFL 10-30L-11TN 2-98IFL 10-30L-11TP 2-98IFL 10-30M-10ST1P 2-94IFL 15-30-01T 2-99IFL 15-30-10T 2-99IFL 15-30L-10/01N 2-94IFL 15-30L-10/01P 2-94IFL 15-30L-10TN 2-94IFL 15-30L-10TP 2-94IFL 15-30L-11TN 2-98IFL 15-30L-11TP 2-98IFL 15-30M-10ST1P 2-94, 2-95IFL 15-333-10/01 2-106IFL 15-333E-11N 2-103IFL 15-333E-11P 2-103IFL 20-333-10/01 2-106IFL 20-333E-11N 2-103IFL 20-333E-11P 2-103IFL 50-385-10/01 2-106IFL 50-385-11N-M20 2-103IFL 50-385-11P-M20 2-103IFMA0035 11-508IFMA0065 11-508IFMR0036 11-509IFMR0066 11-509IP 2S 17-761IP 3S 17-761IP 4S 17-761IP 5S 17-761IRMA3035 11-507ISDA054970R1 13-593IS-LCP-18 16-730IS-LCP-18-PCB 16-730IS-LCP-36 16-730IS-LCP-36-PCB 16-730IS-SL7v5 16-726IS-SL7v5-EC90 16-726IS-SL7v5-G 16-726IS-SL18 16-726IS-SL18-EC90 16-726IS-SL18-G 16-726IS-SL36 16-726IS-SL36-EC90 16-726IS-SL36-G 16-726IS-SL420 16-726IS-SL420-EC90 16-726IS-SL420-G 16-726IS-SL485 16-727IS-SL485-EC90 16-727IS-SL485-G 16-727IS-SLDH 16-727IS-SLDH-EC90 16-727IS-SLDH-G 16-727IS-SLDIN-EC90 16-726, 16-728IS-SLDIN-G 16-726, 16-728IS-SL-RTD 16-727
773
Product Code Index
IS-SL-RTD-EC90 16-727IS-SL-RTD-G 16-727IS-SLT1-7V5-M20 16-729IS-SLT1-7V5-N12 16-729IS-SLT1-7V5-N34 16-729IS-SLT1-18-M20 16-729IS-SLT1-18-N12 16-729IS-SLT1-18-N34 16-729IS-SLT1-36-M20 16-729IS-SLT1-36-N12 16-729IS-SLT1-36-N34 16-729IS-SSP6A-14 16-728IS-SSP6A-14-EC90 16-728IS-SSP6A-14-G 16-728IS-SSP6A-26 16-728IS-SSP6A-26-EC90 16-728IS-SSP6A-26-G 16-728IS-SSP6A-38 16-728IS-SSP6A-38-EC90 16-728IS-SSP6A-38-G 16-728ITMA3035 11-507IZUK 6/2 17-751IZUK 6/3 17-751IZUK 6/4 17-751IZUK 6/10 17-751IZUK 10/2 17-751IZUK 10/3 17-751IZUK 10/4 17-751IZUK 10/10 17-751
KK-14 12-536KA 0804 6-327, 6-328, 6-330KA 0805 6-327, 6-328, 6-330KA 0808 6-327, 6-328, 6-330KA 0904 6-327, 6-328, 6-330KA 0905 6-327, 6-328, 6-330KA 0908 6-327, 6-328, 6-330KA18072 12-535KA18120 12-535KA18121 12-535KB14010 12-531KB14040 12-531KC1060K 12-541KC1080K 12-541KC1260K 12-541KC1280K 12-541KC5040K 12-541KC6040K 12-541KC7050K 12-541KC8060K 12-541KD3 GREY 17-744, 17-750, 17-751, 17-752, 17-755, 17-758, 17-759KD4 GREY 17-744, 17-747, 17-748, 17-749, 17-750, 17-751, 17-752, 17-755, 17-756, 17-757, 17-758, 17-759, 17-760KD6 GREY 17-745, 17-747, 17-748, 17-749, 17-756, 17-757, 17-760KD7 GREY 17-744, 17-747, 17-748, 17-749, 17-750, 17-751, 17-752, 17-755, 17-756, 17-757, 17-758, 17-759, 17-760KKB 17-762, 17-763KKB 95 GREY 17-746KKB 150 GREY 17-746KKB 240 GREY 17-746KKC 1006 17-762, 17-763KKC 1008 17-762, 17-763KKC 1206 17-762, 17-763KKC 1208 17-762, 17-763KKC 2530 17-762, 17-763KKC 2540 17-762, 17-763KKC 2560 17-762, 17-763KKC 4040 17-762, 17-763KKC 4060 17-762, 17-763KKC 4080 17-762, 17-763KKC 6040 17-762, 17-763KKC 6060 17-762, 17-763KKC 6080 17-762, 17-763KKC 8060 17-762, 17-763KKC 8080 17-762, 17-763KKK 25 17-762KKK 40 17-762KKK 60 17-762KKK 80 17-762KKK 100 17-762KKK 120 17-762KKM 17-762, 17-763KKMR 17-762KKT 40 x 40 17-763KKT 40x40 17-762KKT 40 x 60 17-763KKT 40x60 17-762KKT 40x80 17-762KKT 60 x 80 17-763
KOIPSMW* 17-761KP1 16-705, 16-724KP1-i 16-724KP10 16-705, 16-724KP10-i 16-724KTR11001 12-533KTR11002 12-533KTR11012 12-533KTR11013 12-533KTR12012 12-534KTR12013 12-534KZSO 12-536
LLA12858 12-540LA12864 13-579LA12865 13-579LA12866 13-579LA12867 13-579LC2H-F-2KK 4-178LC2H-F-DL-2KK 4-178LC2H-F-DL-2KK-B 4-178LC2H-F-FV-30 4-178LC4H-R4-AC240V 4-180LC4H-R4-AC240VS 4-180LC4H-R4-DC24V 4-180LC4H-R4-DC24VS 4-180LC4H-R6-AC240V 4-180LC4H-R6-AC240VS 4-180LC4H-R6-DC24V 4-180LC4H-R6-DC24VS 4-180LC4HW-R6-AC24V 4-180LC4HW-R6-AC24VS 4-180LC4HW-R6-AC240V 4-180LC4HW-R6-AC240VS 4-180LC4HW-R6-DC24V 4-180LC4HW-R6-DC24VS 4-180LCP-18 16-712LCP-18-PCB 16-712LCP-36 16-705, 16-712LCP-36-PCB 16-712LD2A05P0 4-227LD2SG5P0 4-229LD2SS6P0 4-228LD2T06P0 4-229LD4A05P0 4-227LD4SG5P0 4-229LD4SS6P0 4-228LD4T06P0 4-229LD2006P0 4-228LD4006P0 4-228LD200400 4-228LD200600 4-228LD400400 4-228LD400600 4-228LDC4 14-638LE24/9 WS 12-515, 12-519, 12-520LE185 14-627, 14-629LE230/9 WS 12-515LE300 14-627, 14-629LE460 14-629LE750 14-629LE00846 12-540LE00850 12-540LE00851 12-540LE00852 12-540LE00854 12-540LE00856 12-540LE00858 12-540LE00860 12-540LE00862 12-540LE00864 12-540LE00872 12-540LE00874 12-540LE00876 12-540LE00878 12-540LE00880 12-540LE00882 12-540LE00884 12-540LE12402 13-579LE12404 13-579LE12406 13-579LE12408 13-579LE12644 13-579LE12646 13-579LE12650 13-579LE12652 13-579LE12804 12-540LE12808 12-540LE12812 12-540LE12814 12-540LE12816 12-540LE12818 12-540
LF12WPP 13-579LF24WPP 13-579LF36WPP 13-579LF54WPP 13-579LF12041 13-579LF12045 13-579LF12048 13-579LF12052 13-579LF12061 13-579LF12063 13-579LF12065 13-579LF12067 13-579LH2H-F-DHK 1-44LH2H-F-DHK-DL 1-44LH2H-F-DHK-FV 1-44LH2H-F-HMK 1-44LH2H-F-HMK-DL 1-44LH2H-F-HMK-FV 1-44LMK 306 5-234, 5-239LMK 307 5-234, 5-241LMK 331 5-234, 5-250LMK 351 5-234, 5-251LMK 358H 5-234, 5-247LMK 382 5-234, 5-243LMK 382H 5-234, 5-248LMK 807 5-234, 5-244LMK 809 5-234, 5-245LMP 305 5-234, 5-238LMP 307 5-234, 5-240LMP 307T 5-234, 5-242LMP 308i 5-234, 5-246LMP 331 5-234, 5-249LP00900 12-540LP00902 12-540LP00904 12-540LP12842 12-540LP12844 12-540LP12845 12-540LP12846 12-540LP12847 12-540LP12848 12-540LPAX0500 4-230LPAX0600 4-230LPAXCK00 4-230LPAXDA00 4-230LS-401-C2 2-81, 2-90LS-401P-C2 2-81, 2-90LS12442 13-579LS12444 13-579LS12446 13-579LS12447 13-579LS12462 13-579LS12464 13-579LS12466 13-579LS12467 13-579LS12744 13-579LS12748 13-579LS12752 13-579LS12754 13-579LS12756 13-579LS-H21 2-81, 2-90LS-H22 2-81, 2-90LS-H91 2-81, 2-90LS-H92 2-81, 2-90LT4H8-AC24V 1-38LT4H8-AC240V 1-38LT4H8-DC24V 1-38LT4H-AC24V 1-38LT4H-AC240V 1-38LT4H-DC24V 1-38LT4H-DC24VS 1-38LT4HL8-AC24V 1-38LT4HL8-AC240V 1-38LT4HL8-DC24V 1-38LT4HW8-AC24V 1-38LT4HW8-AC240V 1-38LT4HW8-DC24V 1-38LT4HW-AC24V 1-38LT4HW-AC240V 1-38LT4HW-DC24V 1-38LT185-AC 14-627LT185AC 14-629LT185-AL 14-627LT185AL 14-629LT300-AC 14-627LT300AC 14-629LT300-AL 14-627LT300AL 14-629LT460AC 14-629LT460AL 14-629LT750AC 14-629LT750AL 14-629LUZB12.051 3-141LUZB12.071 3-141LUZB12.121 3-141LUZB12.261 3-141
LUZB12.351 3-141LUZB12.551 3-141LUZB12.751 3-141LUZB12.1001 3-141LUZB12.1201 3-141LW110 14-627, 14-629LW185 14-627, 14-629LW300 14-627, 14-629LW460 14-629LW750 14-629LX-101 2-80LX-101-P 2-80, 2-89LX-101-P-Z 2-80, 2-89LX-101-Z 2-80, 2-89LX185 14-629LX300 14-629LX460 14-629LX750 14-629
MM2C 441-11Y-M20 2-57M2L 035-11Z 2-58M2S 015-11Y-M20 2-56M2S 330-11Y-M20 2-53M2S 441-11Y-M20 2-57M2SS110B 12-523M2SS111C 12-524M2SS111G 12-524M2SS111L 12-524M2SS111R 12-524M2SS111Y 12-524M2SS140B-20 12-523M2SS210B 12-523M2SS240B-11 12-523M2SS240B-20 12-523M2SS310B 12-523M2SS410B 12-523M2SS510B 12-523M2SS610B 12-523M2SSK1101 12-528M2SSK2101 12-528M2SSK3101 12-528M3SS110B 12-523M3SS111C 12-524M3SS111G 12-524M3SS111L 12-524M3SS111R 12-524M3SS111Y 12-524M3SS140B-20 12-523M3SS210B 12-523M3SS310B 12-523M3SS410B 12-523M3SS510B 12-523M3SS710B 12-523M3SSK1101 12-528M3SSK2101 12-528M3SSK3101 12-528M3SSK4101 12-528M3SSK5101 12-528M3V4D 330-11Y-M20 2-53M-4 2-122M7/MV7/59/76A/103/115 2-77M12DRC-ISO 10-474M12DRC-MTL 10-474M12/MV12-F1/76b/82b/115/128 2-77M41G 1-21, 1-23M42G 1-21, 1-23M43G 1-21, 1-23M51 1-21, 1-23M52 1-21, 1-23M53 1-21, 1-23M61G 1-21, 1-23M61R 1-21, 1-23M62G 1-21, 1-23M62R 1-21, 1-23M63G 1-21, 1-23M63R 1-21, 1-23M 250-11Z-1224 2-62M 250-22Z-1224 2-62M 441-11Y-14 2-63M.441-11Y-243 2-63M.441-11Y-966 2-63M.441-11Y-1224 2-63MA18001 12-532MA18130 12-535MA18131 12-532MA61036 12-535MA61037 12-535MA61038 12-535MA61039 12-535MA61042 12-535MA61043 12-535MA61044 12-535
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
MA61045 12-535MA61047 12-535MA61054 12-535MA61056 12-535MA61057 12-535MA61058 12-535MA61073 12-535MA61085 12-535MA61086 12-535MA61101 12-535MAC022XXXG42 15-675MAC032XXXG42 15-675MAC040XXXG42 15-675MAF 330-11Y-M20 2-53MBG 311/GB 12-522MBK 311/GB 12-522MBLPAX00 4-231MBN 12-536M-C 2-122MCB01 12-513, 12-521, 12-523, 12-524, 12-528, 12-530, 12-533MCB01B 12-532MCB02 12-533MCB10 12-513, 12-521, 12-523, 12-524, 12-528, 12-530, 12-533MCB10B 12-532MCB11 12-533MCB20 12-533MCBH00 12-518, 12-533MCBH-01 12-513, 12-521, 12-523, 12-524, 12-528, 12-530, 12-533MCBH-02 12-513, 12-521, 12-523, 12-524, 12-528, 12-530, 12-533MCBH-003 12-513MCBH-10 12-512, 12-513, 12-523, 12-524, 12-528, 12-530, 12-533MCBH-11 12-513, 12-521, 12-523, 12-524, 12-528, 12-530, 12-533MCBH-20 12-513, 12-523, 12-524, 12-528, 12-530, 12-533MCBH-101 12-533MCBH-111 12-533MCBH500 12-533MD 250-02/02Z 2-58MD 250-02Z 2-58MD 250-11Z 2-58MD 441-11Y-M20 2-57MDB1 12-534MDT-8/PTFE 12-536ME1-1 Transparent 17-761ME1-2 Transparent 17-761ME 3 Transparent 17-761ME 4 17-761MEP1 12-532MEP2 12-532MEP3 12-532MEP4 12-532MEP6 12-532MEP21001 12-532MEPY1 12-532MEPY11005 12-532MEPY11015 12-532MIL-324-1 10-473MIL-326-1 10-473M-J 2-122MJ 441-11Y-M20 2-57MK 015-11Y-M20 2-56MKTA32 12-539MKTB32 12-539MKTB32/1x401 12-539MKTC32 12-539MKTC42 12-539MKTC52 12-539MKTC52/2x401 12-539MKTE32 12-539MKTE52 12-539MKTE52/206 12-539ML7-8-200/25/103/115 2-73ML7-55/59/103/115 2-68ML15.051 3-130ML15.121 3-130ML15.241 3-130ML30.100 3-130ML30.101 3-130ML30.102 3-130ML30.106 3-130ML30.241 3-130ML50.101 3-130ML50.102 3-130ML50.105 3-130ML60.121 3-130ML60.241 3-130ML70.100 3-130ML100.100 3-130ML100.102 3-130ML100.105 3-130ML100.109 3-130
ML120.241 3-130ML 441-11Y-M20 2-57ML1100C 12-518ML1100G 12-518ML1100L 12-518ML1100R 12-518ML1100W 12-518ML1100Y 12-518MLB1 12-533MLB1B 12-532MLB2 12-533MLB2B 12-532MLB3 12-533MLB3B 12-532MLB4 12-533MLB5 12-533MLBL01G 12-518MLBL01L 12-518MLBL01R 12-518MLBL01W 12-518MLBL01Y 12-518MLBL07G 12-518MLBL07L 12-518MLBL07R 12-518MLBL07W 12-518MLBL07Y 12-518MLPS1000 1-36, 1-43, 4-179, 4-182, 4-184, 4-187, 4-189, 4-201, 4-203, 4-208, 4-210, 4-216MLV12-8-H-250-RT/65b/115/128 2-73MLV12-54/76b/115/128 2-68MLY10.241 3-136MO1320.4 14-642MO1320.16 14-642MO1320.25 14-642MO1320.63 14-642MO1321.0 14-642MO1321.6 14-642MO1322.5 14-642MO1324.0 14-642MO1326.3 14-642MO13210 14-642MO13212 14-642MO13216 14-642MO13220 14-642MO13225 14-642MP130B 12-512MP130G 12-512MP130L 12-512MP130R 12-512MP130W 12-512MP130Y 12-512MP131M 12-513MP160G-10 12-512MP160R-01 12-512MP230M 12-512MP231M 12-513MP330B 12-512MP330G 12-512MP330L 12-512MP330R 12-512MP330W 12-512MP330Y 12-512MP331M 12-513MP360R-01 12-512MP430M 12-512MP431M 12-513MPAXC020 4-231MPAXC030 4-231MPAXCK00 4-231MPAXCK10 4-231MPAXD000 4-230MPAXD010 4-230MPAXDP00 4-231MPAXDP10 4-231MPAXDR00 4-231MPAXDR10 4-231MPAXH000 4-230MPAXI020 4-231MPAXI030 4-231MPAXP000 4-230MPAXP010 4-230MPAXR020 4-231MPAXR030 4-231MPAXS000 4-230MPAXS010 4-230MPAXT000 4-230MPAXT010 4-230MP-AZ/AZM 300-1 6-304MPD211B 12-512MPD211C 12-513MPD1311B 12-512MPD1311C 12-513MPD1511B 12-512MPD1511C 12-513MPM110B 12-512
MPM110R 12-512MPM110Y 12-512MPM111R 12-513MPM111Y 12-513MPMP310R 12-521MPMP410R 12-521MPMT310B 12-521MPMT310R 12-521MPMT311R 12-521MPMT320R-02 12-521MPMT320R-11 12-521MPMT410R 12-521MPMT411R 12-521MPOT-01 14-610MPP-RJ12 16-705MPP-RJ12-1 16-725MPP-RJ12-2 16-725MPP-RJ45 16-705, 16-725MR 35 x 7.5 17-762MR 441-11Y-M20 2-57MR-EI1W1P 1-32MR-ET1P 14-620MR-EU1W1P 1-31MR-EU3M1P 1-31MS 015-11Y-M20 2-56MS116AA124 14-645MS116AA1110 14-645MS116AA1230 14-645MS116AA1400 14-645MS116HK102 14-645MS116HK111 14-645MS116HK120 14-645MS116HKF111 14-645MS116HKF120 14-645MS116HKF120L 14-645MS116SK102 14-645MS116SK111 14-645MS116SK120 14-645MS116UA124 14-645MS116UA148 14-645MS116UA160 14-645MS116UA1120 14-645MS116UA1230 14-645MS116UA1400 14-645MS116UA1415 14-645MS132CK102 14-645MS132CK111 14-645MS132CK120 14-645MS 330-11Y-M20 2-53MS 441-11Y-M20 2-57MS450-40 14-643MS450-45 14-643MS450-50 14-643MS495-63 14-643MS495-75 14-643MS495-90 14-643MS495-100 14-643MS1160.4 14-642MS1160.16 14-642MS1160.25 14-642MS1160.63 14-642MS1161 14-642MS1161.6 14-642MS1162.5 14-642MS1164 14-642MS1166.3 14-642MS1320.4 14-642MS1320.16 14-642MS1320.25 14-642MS1320.63 14-642MS1321.0 14-642MS1321.6 14-642MS1322.5 14-642MS1324.0 14-642MS1326.3 14-642MS11610 14-642MS11612 14-642MS11616 14-642MS11620 14-642MS11625 14-642MS11632 14-642MS13210 14-642MS13212 14-642MS13216 14-642MS13220 14-642MS13225 14-642MS13232 14-642MS-AJ3 2-66, 2-70, 2-75MS-CX-1 2-67MS-CX2-1 2-72, 2-76MS-CX-3 2-67, 2-72, 2-76MS-CY1-1 2-66, 2-70, 2-75MS-CY1-2 2-66, 2-70, 2-75MS-EQ3-1 2-74MS-EQ3-2 2-74MS-EXL2-1 2-81
MS-GXL8-4 2-101MSH-AR 14-647MSHDLB 14-647MSHDLTB 14-647MSHDLTY 14-647MSHDLY 14-647MS-LX-1 2-80MS-LX-2 2-80MSMN 14-647MSMNO 14-647MS MZM 100-W 6-308, 6-309MS-NX5-1 2-68, 2-72, 2-76MS-NX5-2 2-68, 2-72, 2-76MS-NX5-3 2-68, 2-72, 2-76MSOX30 14-647MSOX32 14-647MS-RF21-1 2-81MT105B 12-531MT310B 12-531MTS110B 12-530MTS210B 12-530MTS310B 12-530MT-TSD-17S-11-9240 1-39MT-TUA-17S-11-9240 1-33MT-TUB-17S-11-9240 1-33MUE 12-536MV3H 015-11Y 2-56MV7H 015-11Y 2-56MV7H 330-11Y-M20 2-53MV8H 015-11Y 2-56MV8H 330-11Y-M20 2-53MV10H 015-11Y 2-56MV10H 330-11Y-M20 2-53MV10H 330-11Y-M20-1348 2-62MV 330-11Y-M20 2-53MVH 330-11Y-M20 2-53MWB2KN200 2-122MWB2KN2006MM 2-122MWB2KN20010MM 2-122MWB2RU200 2-122MWB2RU2006MM 2-122MWB2RU20010MM 2-122MWB3KN300 2-122MWB3KN3006MM 2-122MWB3KN30010MM 2-122MWB3RU300 2-122MWB3RU3006MM 2-122MWB3RU30010MM 2-122MWB4KN400 2-122MWB4KN4006MM 2-122MWB4KN40010MM 2-122MWB4RU400 2-122MWB4RU4006MM 2-122MWB4RU40010MM 2-122MWB5KN500 2-122MWB5KN5006MM 2-122MWB5KN50010MM 2-122MWB5RU500 2-122MWB5RU5006MM 2-122MWB5RU50010MM 2-122MZM 100 - B1.1 6-308MZM 100 ST2-1P2PW-A 6-308MZM 120 - B1.1 6-309MZM 120BM ST2- 1P2PW2RE-A 6-309MZM 120B ST2- 1P2PW2RE-A 6-309MZSO 12-536
nNBB2-8GM50-E0 2-96NBB2-8GM50-E2 2-96NBB2-12GM50-E0 2-96NBB2-12GM50-E0-V1 2-96NBB2-12GM50-E2 2-96NBB2-12GM50-E2-V1 2-96NBB5-18GM50-E0 2-96NBB5-18GM50-E0-V1 2-96NBB5-18GM50-E2 2-96NBB5-18GM50-E2-V1 2-96NBB10-30GM50-E0 2-96NBB10-30GM50-E0-V1 2-96NBB10-30GM50-E2 2-96NBB10-30GM50-E2-V1 2-96NBB15-U1-A0 2-104NBB15-U1-A2 2-104NBB15-U1-Z2 2-105NBB20-U1-A0 2-104NBB20-U1-A2 2-104NBB20-U1-Z2 2-105NBN2-8GM50-E0 2-96NBN2-8GM50-E2 2-96NBN4-12GM50-E0 2-96NBN4-12GM50-E0-V1 2-96NBN4-12GM50-E2 2-96
775
Product Code Index
NBN4-12GM50-E2-V1 2-96NBN8-18GM50-E0 2-96NBN8-18GM50-E0-V1 2-96NBN8-18GM50-E2 2-96NBN8-18GM50-E2-V1 2-96NBN15-30GM50-E0 2-96NBN15-30GM50-E0-V1 2-96NBN15-30GM50-E2 2-96NBN15-30GM50-E2-V1 2-96NBN30-U1-A0 2-104NBN30-U1-A2 2-104NBN30-U1-Z2 2-105NBN40-U1-A0 2-104NBN40-U1-A2 2-104NBN40-U1-Z2 2-105NBSY 12-537NCN50-FP-A2-P1 2-104NCN50-FP-W-P1 2-107NCN50-FP-Z2-P1 2-105NDAN 6 12-531NDL BL 12-517NDL GB 12-517NDL GN 12-517NDL RT 12-517NDL WS 12-517NDP 50BL 12-516NDP 50GB 12-516NDP 50GN 12-516NDP 50SW 12-516NDP 50WS 12-516NDP-70/Emergency-Stop 12-522, 12-537NDRR 50RT 12-522NDT BL 12-516NDT GB 12-516NDT GN 12-516NDT GR 12-516NDT RT 12-516NDT SW 12-516NDT WS 12-516NJ15+U1+W 2-107NJ20+U1+W 2-107NJ30+U1+W 2-107NJ40+U1+W 2-107NMEF BL 12-520NMEF GB 12-520NMEF GN 12-520NMEF RT 12-520NMEF WS 12-520NML BL 12-520NML GB 12-520NML GN 12-520NML RT 12-520NML WS 12-520NP-9135 3-145, 3-146, 3-147, 3-148, 3-149, 3-150, 3-152, 3-153, 3-154, 3-155, 3-156, 3-157NP-9155 3-146, 3-147, 3-153, 3-154NPP 2.5-10 GREY 17-744NPP 16 GREY 17-744NPP ASK 2 GREY 17-750, 17-752NPP ASK 3 GREY 17-750, 17-752NPP AVK 2.5 CC GREY 17-750NPP PIK2.5-4N GREY 17-747NPP PIK2.5-4N YELLOW-GREEN 17-747NPP PIK10N GREY 17-747NPP PUK2T GREY 17-748NPP PUK3 GREY 17-748NPP PUK 3S GREY 17-749NPP PUK3T GREY 17-748NPP PYK 1.5-2.5 T YELLOW-GREEN 17-755NPP PYK 2.5-2F GREY 17-756NPP PYK 2.5-3F GREY 17-756NPP PYK 2.5-3FT GREY 17-756NPP PYK 2.5A 17-758NPP PYK 2.5 C GREY 17-760NPP PYK 2.5 CT YELLOW-GREEN 17-760NPP PYK 2.5 E GREY 17-760NPP PYK 2.5 ET YELLOW-GREEN 17-760NPP PYK 2.5 GREY 17-755NPP PYK 3S GREY 17-757NPP PYK 4 E GREY 17-760NPP PYK 4 GREY 17-755NPP PYK 4 T YELLOW-GREEN 17-755NPP PYK 6 GREY 17-755NPP PYK 6 T YELLOW-GREEN 17-755NPP PYK 10 GREY 17-755NPP PYK 10 T YELLOW-GREEN 17-755NPP WGO 2N GREY 17-751NPP WGO 3 GREY 17-751NR25 2-123, 2-125NT24K-AC1 10-470NT24K-AC1-DC1 10-470NT24K-AC2 10-470NT24K-DC1 10-470NT24K-DC2 10-470
NT24K-DR16-AC 10-470NT24K-DR16-DC 10-470NT24K-DR24-AC 10-470NT24K-DR24-DC 10-470NT24K-FP 10-471NT24K-FX8-XX 10-471NT24K-FXE8-XX-YY 10-471NT24K-GX8-SC 10-471NT24K-GXE8-SC-ZZ 10-471NT24K-SFP8 10-471NT24K-SFP-DM8 10-471NT24K-TX8 10-471NT24-PMK 10-471NTCD 10-466NTCD-CFG 10-471NTSFP-FX 10-471NTSFP-FXE-YY 10-471NTSFP-LX-ZZ 10-461, 10-466, 10-469, 10-471NTSFP-SX 10-461, 10-466, 10-469, 10-471NTSFP-TX 10-466, 10-469, 10-471NUE1 12-537NWS 21.1 WS 12-526NWS 21 WS 12-526NWS 32.1 WS 12-526NWS 32 WS 12-526NWSE2K 12-527NWSE3K 12-527NWSE4K 12-527NWSE5K 12-527NWSE6K 12-527NWSE7K 12-527NWSE8K 12-527NWSE9K 12-527NWSE10K 12-527NWSE11K 12-527NWSE12K 12-527NWT 21.1 WS 12-526NWT 21 WS 12-526NWT 32.1 WS 12-526NWT 32 WS 12-526NWTS 321.1 WS 12-526NWTS 321 WS 12-526NX5-D700A 2-72, 2-86NX5-D700B 2-72, 2-86NX5-M10RA 2-76, 2-86NX5-M10RB 2-76, 2-86NX5-M30A 2-76, 2-86NX5-M30B 2-76, 2-86NX5-PRVM5A 2-68NX5-PRVM5B 2-68NX5-RM7A 2-68NX5-RM7B 2-68NZSO/1/V4A 12-537NZSO/2/V4A 12-537NZSO/V4A 12-537
OOA1G01 13-590OA1G10 13-586, 13-591OA1G109 13-590OA2G11 13-586, 13-590, 13-591OA3G01 13-586, 13-591OAZX1 13-590OBEA01 13-590OBEA10 13-590OEA28 13-591OESAZW1 13-595OESAZW2 13-594, 13-595OESAZX167 13-589OETL3150 13-584OETL3150K3 13-584OETL3150K4 13-584OETL3150K185 13-584OETL3150KV12 13-584OETL3150KV22 13-584OETLZK19 13-589OETLZW3 13-594, 13-595OETLZW9 13-594, 13-595OETLZW11 13-594, 13-595OETLZW12 13-594, 13-595OETLZW13 13-594, 13-595OETLZW14 13-594, 13-595OETLZW15 13-594, 13-595OETLZX95 13-589OEZNP1 13-590OFAE 504 13-599OFAF000H2 13-599OFAF000H4 13-599OFAF000H6 13-599OFAF000H10 13-599OFAF000H16 13-599OFAF000H20 13-599
OFAF000H25 13-599OFAF000H32 13-599OFAF000H35 13-599OFAF000H40 13-599OFAF000H50 13-599OFAF000H63 13-599OFAF000H80 13-599OFAF000H100 13-599OFAF00H125 13-599OFAF00H160 13-599OFAF0H200 13-599OFAF1H16 13-599OFAF1H20 13-599OFAF1H25 13-599OFAF1H32 13-599OFAF1H35 13-599OFAF1H40 13-599OFAF1H50 13-599OFAF1H63 13-599OFAF1H80 13-599OFAF1H100 13-599OFAF1H125 13-599OFAF1H160 13-599OFAF1H200 13-599OFAF1H224 13-599OFAF2H80 13-599OFAF2H100 13-599OFAF2H125 13-599OFAF2H160 13-599OFAF2H200 13-599OFAF2H224 13-599OFAF2H250 13-599OFAF2H300 13-599OFAF2H315 13-599OFAF2H355 13-599OFAF2H400 13-599OFAF3H250 13-599OFAF3H300 13-599OFAF3H315 13-599OFAF3H355 13-599OFAF3H400 13-599OFAF3H425 13-599OFAF3H450 13-599OFAF3H500 13-599OFAF3H630 13-599OFAF3H800 13-599OFAX 00 P1 13-598OFAX 00 P3 13-598OFAX 00 S1 13-598OFAX 00 S3 13-598OFAX 1 P1 13-598OFAX 1 P3 13-598OFAX 1 S1 13-598OFAX 1 S3 13-598OFAX 2 P1 13-598OFAX 2 P3 13-598OFAX 2 S1 13-598OFAX 2 S3 13-598OFAX3P1 13-598OFAX3P3 13-598OFAX3S1 13-598OFAX3S3 13-598OHB45J6 13-587OHB65J6 13-587OHB65J6T 13-587OHB80J6 13-587OHB95J12 13-587OHB125J12 13-587OHB200J12P 13-587OHB274J12 13-584, 13-587OHBS2AJ 13-587OHBS2PJ 13-582, 13-587OHBS2RJ 13-582OHBS3AH1 13-587OHBS9 13-587OHM65L6 13-588OHM125L12 13-588OHM175L12 13-588OHM200L12P 13-588OHM275L12 13-588OHRS9 13-587OHY45J6 13-587OHY65J6 13-587OHY65J6T 13-587OHY80J6 13-587OHY95J12 13-587OHY125J12 13-587OHY274J12 13-587OHYS2AJ 13-587OHYS2PJ 13-582, 13-587OHYS2RJ 13-582OHYS3AH1 13-587OHZX5 13-588OMH-ML7-01 2-68, 2-73, 2-77OMH-MLV12-HWK 2-68, 2-73, 2-77OMH-RL39 2-69, 2-74, 2-77
OT16F3 13-582OT16F3CD 13-585OT16F3CP 13-585OT16F3P 13-580OT16F3S 13-580OT16F4CD 13-585OT16F4CP 13-585OT16F4P 13-580OT16F4S 13-580OT16F6D 13-581OT16F6P 13-581OT16F8D 13-581OT16F8P 13-581OT16FT3 13-582OT25F3 13-582OT25F3CD 13-585OT25F3CP 13-585OT25F3P 13-580OT25F3S 13-580OT25F4CD 13-585OT25F4CP 13-585OT25F4P 13-580OT25F4S 13-580OT25F6D 13-581OT25F6P 13-581OT25F8D 13-581OT25F8P 13-581OT25FT3 13-582OT32F3CD 13-585OT32F3CP 13-585OT32F4CD 13-585OT32F4CP 13-585OT40F3 13-582OT40F3P 13-580OT40F3S 13-580OT40F4P 13-580OT40F4S 13-580OT40F6D 13-581OT40F6P 13-581OT40F8D 13-581OT40F8P 13-581OT40FT3 13-582OT45F3CD 13-585OT45F3CP 13-585OT45F4CD 13-585OT45F4CP 13-585OT63F3 13-582OT63F3CD 13-585OT63F3CP 13-585OT63F3P 13-580OT63F3S 13-580OT63F4CD 13-585OT63F4CP 13-585OT63F4P 13-580OT63F4S 13-580OT63F6D 13-581OT63F6P 13-581OT63F8D 13-581OT63F8P 13-581OT63FT3 13-582OT80F3 13-582OT80F3P 13-580OT80F3S 13-580OT80F4P 13-580OT80F4S 13-580OT80F6D 13-581OT80F6P 13-581OT80F8D 13-581OT80F8P 13-581OT80FT3 13-582OT100F3 13-582OT100F3CD 13-585OT100F3CP 13-585OT100F3P 13-580OT100F3S 13-580OT100F4CD 13-585OT100F4CP 13-585OT100F4P 13-580OT100F4S 13-580OT100F6D 13-581OT100F6P 13-581OT100F8D 13-581OT100F8P 13-581OT100FT3 13-582OT125A3 13-582OT125F3 13-582OT125F3CD 13-585OT125F3CP 13-585OT125F3P 13-580OT125F3S 13-580OT125F4CD 13-585OT125F4CP 13-585OT125F4P 13-580OT125F4S 13-580OT125F6D 13-581OT125F6P 13-581
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
OXP6X430 13-589OXP12X250 13-589OXP12X280 13-584OXP12X325 13-584, 13-589OXP12X395 13-589OXP12X465 13-589OXP12X535 13-589OXP612X190 13-589OXS6X85 13-589OXS6X120 13-589OXS6X180 13-589, 14-647OXS6X250 13-589OXS6X330 13-589OXZK4 13-591OZXB 2 13-598OZXB 3 13-598OZXB 4 13-598OZXB 5 13-598OZXK1 13-591OZXK2 13-591OZXK3 13-591OZXK5 13-591OZXK6 13-591
PP481010A 4-196P481011A 4-196P1610000 4-194P1610010 4-194P1611100 4-194P1611110 4-194P1620000 4-194P1620010 4-194P1621100 4-194P1621110 4-194P1641100 4-194P1641110 4-194P4800001 4-196P4800011 4-196P4810000 4-196P4810010 4-196P4810101 4-196P4810105 4-196P4810107 4-196P4810111 4-196P4810115 4-196P4810117 4-196P4811100 4-196P4811102 4-196P4811110 4-196P4811112 4-196PA 430 5-269PAX2A000 4-191, 4-205, 4-212, 4-218PAX2D000 4-186PAX2S000 4-221PAXC0020 4-181PAXC0030 4-181PAXCDC1C 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC2C 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC4C 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC10 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC20 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC30 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC40 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDC50 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDL10 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-218, 4-221PAXCDS10 4-181, 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDS20 4-181, 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204,
4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDS30 4-181, 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCDS40 4-181, 4-183, 4-185, 4-186, 4-190, 4-191, 4-192, 4-197, 4-204, 4-205, 4-207, 4-211, 4-212, 4-214, 4-217, 4-218, 4-220, 4-221, 4-231PAXCK000 1-37PAXCK010 1-37PAXD0000 4-204, 4-211PAXD0010 4-204, 4-211PAXDP000 4-192PAXDP010 4-192PAXDR000 4-183PAXDR010 4-183PAXH0000 4-207, 4-214PAXI0020 4-185PAXI0030 4-185PAXLA000 4-189, 4-203, 4-210PAXLBK10 4-188, 4-190, 4-192, 4-202, 4-204, 4-207, 4-209, 4-211, 4-214, 4-220PAXLBK30 4-187, 4-188, 4-189, 4-201, 4-203, 4-206, 4-208, 4-210, 4-213, 4-219PAXLC600 4-179PAXLC800 4-179PAXLCL00 4-187PAXLCR00 4-184PAXLHV00 4-213PAXLIA00 4-206PAXLID00 4-201PAXLIT00 4-206PAXLPV00 4-188PAXLR000 4-182PAXLRT00 4-215PAXLSG00 4-219PAXLT000 4-216PAXLTC00 4-215PAXLVA00 4-213PAXLVD00 4-208PAXP0000 4-190PAXP0010 4-190PAXR0020 4-183PAXR0030 4-183PAXS0000 4-220PAXS0010 4-220PAXT0000 4-217PAXT0010 4-217PCACL00-00 15-662PCADL00-00 15-662PFA2C10-82 15-662PFA6C11-12 15-655PFA6C11-62 15-655PFA6411-12 15-655PFA6411-62 15-655PFE420-00 15-662PFE421-00 15-662PFE422-00 15-662PFE425-00 15-662PFE430-00 15-662PFE825-00 15-662PFE830-00 15-662PFE835-00 15-662PF-EXL2 2-81PFM1608B 4-227PFM2412B 4-227PFSW399-00 15-662PGMMOD00 11-502, 11-506PI6W-1P-12VDC 1-29PI6W-1P-24VAC/DC 1-29PI6W-1P-115VAC/DC 1-29PI6W-1P-230VAC/DC 1-29PIK 2.5N BLUE 17-747PIK 2.5N GREY 17-747PIK 2.5NT YELLOW-GREEN 17-747PIK 4N BLUE 17-747PIK 4N GREY 17-747PIK 4NT YELLOW-GREEN 17-747PIK 10N GREY 17-747PIR6W-1P-12VDC 1-29PIR6W-1P-24VAC/DC 1-29PIR6W-1P-24VAC/DC-01 1-29PIR6W-1P-115VAC/DC 1-29PIR6W-1P-230VAC/DC 1-29PISA11.401 3-138PISA11.402 3-138PISA11.403 3-138PISA11.404 3-138PISA11.406 3-138PISA11.410 3-138PISA11.203206 3-138PISA11.206212 3-138PISA11.CLASS2 3-138PM4HA-H-24V 1-34PM4HA-H-AC240V 1-34
PM4HA-H-AC240VS 1-34PM4HA-H-AC240VW 1-34PM4HA-H-DC12V 1-34PM4HF8-M-AC24V 1-40PM4HF8-M-AC120V 1-40PM4HF8-M-AC240V 1-40PM4HF8-M-DC12V 1-40PM4HF8-M-DC24V 1-40PM4HF8R-M-AC24V 1-40PM4HF8R-M-AC120V 1-40PM4HF8R-M-AC240V 1-40PM4HF8R-M-DC12V 1-40PM4HF8R-M-DC24V 1-40PM4HF8R-S-AC24V 1-40PM4HF8R-S-AC120V 1-40PM4HF8R-S-AC240V 1-40PM4HF8R-S-DC24V 1-40PM4HF8-S-AC24V 1-40PM4HF8-S-AC120V 1-40PM4HF8-S-AC240V 1-40PM4HF8-S-DC12V 1-40PM4HF8-S-DC24V 1-40PM4HM-H-24V 1-34PM4HM-H-AC240V 1-34PM4HM-H-AC240VW 1-34PM4HM-H-DC12V 1-34PM4HSDM-S-AC24V 1-39PM4HSDM-S-AC240V 1-39PM4HSD-S-AC24V 1-39PM4HSD-S-AC240V 1-39PM4HS-H-24V 1-34PM4HS-H-24VS 1-34PM4HS-H-AC240V 1-34PM4HS-H-AC240VS 1-34PM4HS-H-AC240VW 1-34PM4HS-H-DC12V 1-34PM4HS-H-DC12VS 1-34PM4HW-H-24V 1-41PM4HW-H-AC240V 1-41PM4HW-H-DC12V 1-41PM130EH-PLUS 15-656PM130E-PLUS 15-656PM130P-PLUS 15-656PM135E 15-657PM135EH 15-657PM135P 15-657PM172EH-N 15-658PM172E-N 15-658PM172P-N 15-658PM175 15-664, 15-665PM175-TFT 15-664PM296 15-663PMK70000 4-193, 4-194, 4-195, 4-196PP10A2-50 16-702PP10A4-50 16-702PP10A6-50 16-702PP10A8-19 16-702, 16-703PP10A8-50 16-702PP15A1-19 16-703PP15A1-50 16-703Proficy Cause+ 9-443Proficy Change Management 9-432Proficy Historian 9-434Proficy Historian Analysis 9-436Proficy HMI/SCADA - Cimplicity 9-428Proficy HMI/SCADA - iFIX 9-430Proficy Maintenance Gateway 9-447Proficy Open Enterprise 9-446Proficy Plant Applications 9-444Proficy Process Systems 9-448Proficy Real-Time Information Portal 9-440Proficy Troubleshooter 9-442Proficy Vision 9-438Proficy Workflow 9-445PROTECT – PE-02 6-319PROTECT – PE-11 6-319PS1-2-0-65 14-646PS1-2-1-65 14-646PS1-2-2-65 14-646PS1-3-0-65 14-646PS1-3-0-100 14-646PS1-3-1-65 14-646PS1-3-1-100 14-646PS1-3-2-65 14-646PS1-3-2-100 14-646PS1-4-0-65 14-646PS1-4-0-100 14-646PS1-4-1-65 14-646PS1-4-1-100 14-646PS1-4-2-65 14-646PS1-5-0-65 14-646PS1-5-0-100 14-646PS1-5-1-65 14-646PS1-5-1-100 14-646PS1-5-2-65 14-646PS 1/12 13-576
OT125F8D 13-581OT125F8P 13-581OT160E3 13-582OT160EV03P 13-583OT160EV12P 13-583OT 200E03CP 13-586OT200E03P 13-583OT200E12P 13-583OT 250E03CP 13-586OT250E03P 13-583OT250E12P 13-583OT 315E03CP 13-586OT315E03P 13-583OT315E12P 13-583OT 400E03CP 13-586OT400E03P 13-583OT400E12P 13-583OT 630E03CP 13-586OT630E03P 13-583OT630E12P 13-583OT 800E03CP 13-586OT800E03P 13-583OT800E12P 13-583OT1000...1250_P 13-584OT 1000E03CP 13-586OT1000E03P 13-584OT1000E12P 13-584OT 1250E03CP 13-586OT1250E03P 13-584OT1250E12P 13-584OT 1600E03CP 13-586OT1600E03P 13-584OT1600E03W8P 13-584OT1600E12P 13-584OT1600_P 13-584OT2000...2500_P 13-584OT 2000E03CP 13-586OT2000E03P 13-584OT2000E12P 13-584OT 2500E03CP 13-586OT2500E03P 13-584OT2500E12P 13-584OTB800/6 13-593OTP125FP 13-592OTPL40FD 13-592OTPL80FD 13-592OTPL125FD 13-592OTPS40FDNI 13-592OTPS40FPN1 13-592OTPS80FD 13-592OTPS80FP 13-592OTPS125FD 13-592OTPS160EP 13-592OTS40T1 13-593OTS40T3 13-586, 13-593OTS63T1 13-593OTS63T3 13-586, 13-593OTS125T1 13-593OTS125T3 13-586, 13-593OTS160T3 13-593OTS250G1L3 13-586, 13-593OTS250G1S3 13-586, 13-593OTS400G1L3 13-586, 13-593OTS400G1S3 13-586, 13-593OTS800G1L3 13-586, 13-593OTS800G1S3 13-586, 13-593OTS1600G1L3 13-586, 13-593OTS1600G1S3 13-586, 13-593OTS2500G1L3 13-586, 13-593OTS2500G1S3 13-586, 13-593OTZ250E 13-592OTZ400E 13-592OTZ800E 13-592OTZ1250E 13-592OTZ1600E 13-592OTZ2500E 13-592OTZW10 13-594, 13-595OTZW17 13-594, 13-595OTZW24 13-594, 13-595OTZW25 13-594, 13-595OTZW26 13-594, 13-595OWP6D40 13-594, 13-595OWP6D80 13-594, 13-595OWP6D125 13-594, 13-595OXN250 13-592OXN400 13-592OXN800T 13-592OXN1250T 13-592OXP6X150 13-589OXP6X210 13-589OXP6X265 13-589OXP6X290 13-589OXP6X360 13-589
777
Product Code Index
PS 1/12N 13-576PS 1/38/6 13-576PS 1/60 13-576PS 1/60/16 13-576PS 2/12 13-576PS 2/58 13-576PS 2/58/16 13-576PS 3/12 13-576PS 3/60 13-576PS 3/60/16 13-576PSC-CPU-MON 6-340PSC-NS-IN 6-340PSC-NS-OUT 6-340PSC-S-IN-E 6-340PSC-S-IN-LC 6-340PSC-S-OUT 6-340PSC-S-RELAYS 6-340PSC-S-STP-E 6-340PSC-S-STP-ELC 6-340PSC-S-STP-LC 6-340PSC-SUB-MON 6-340PSE18-600-70 14-627PSE25-600-70 14-627PSE30-600-70 14-627PSE37-600-70 14-627PSE45-600-70 14-627PSE60-600-70 14-627PSE72-600-70 14-627PSE85-600-70 14-627PSE105-600-70 14-627PSE142-600-70 14-627PSE170-600-70 14-627PSE210-600-70 14-627PSE250-600-70 14-627PSE300-600-70 14-627PSE370-600-70 14-627PSEEK 14-627PS-END 13-576PS-END 0 13-576PS-ENS 1 13-576PSR3-600 14-626PSR6-600 14-626PSR9-600 14-626PSR12-600 14-626PSR16-600 14-626PSR16 MS116 14-626PSR16 MS132 14-626PSR16 MS450 14-626PSR16 MS495 14-626PSR25-600 14-626PSR30-600 14-626PSR37-600 14-626PSR45-600 14-626PSR60-600 14-626PSR72-600 14-626PSR85-600 14-626PSR105-600 14-626PSR FAN 14-626PSR FAN 60 14-626PST30-600 14-628PST37-600 14-628PST44-600 14-628PST50-600 14-628PST60-600 14-628PST72-600 14-628PST85-600 14-628PST105-600 14-628PST142-600 14-628PST175-600 14-628PST210-600 14-628PST250-600 14-628PST300-600 14-628PSTB370-600 14-628PSTB470-600 14-628PSTB570-600 14-628PSTB720-600 14-628PSTB840-600 14-628PSTB1050-600 14-628PSTEK 14-629PTV00000 4-225PUK2T GREY 17-748PUK3 GREY 17-748PUK3S GREY 17-749PUK3 SLD NPN GREY 17-749PUK3 SLD PNP GREY 17-749PUK3T GREY 17-748PWR-M12-A-X 10-474, 10-475PWR-RM12-A-X 10-474, 10-475PX2C8H00 4-197PX2C8V00 4-197PYK 1.5 BLUE 17-754PYK 1.5 GREY 17-754PYK 1.5 T YELLOW-GREEN 17-754PYK 2.5-2F GREY 17-756PYK 2.5-3F GREY 17-756PYK 2.5-3FT GREY 17-756
PYK 2.5A 17-758PYK 2.5 BLUE 17-754PYK 2.5 C GREY 17-760PYK 2.5 CT YELLOW-GREEN 17-760PYK 2.5 E GREY 17-760PYK 2.5 ET YELLOW-GREEN 17-760PYK 2.5 GREY 17-754PYK 2.5 T YELLOW-GREEN 17-754PYK3S GREY 17-757PYK3S SLD NPN GREY 17-757PYK3S SLD PNP GREY 17-757PYK 4 BLUE 17-754PYK 4 E GREY 17-760PYK 4 GREY 17-754PYK 4S 17-759PYK 4 T YELLOW-GREEN 17-754PYK 6 BLUE 17-754PYK 6 GREY 17-754PYK 6 T YELLOW-GREEN 17-754PYK 10 BLUE 17-754PYK 10 GREY 17-754PYK 10 T YELLOW-GREEN 17-754PZ8 1-24PZ11 1-24
QQS3.241 3-132QS5.241 3-132QS5.241-A1 3-132QS5.DNET 3-132QS10.121 3-132QS10.241 3-132QS10.241-A1 3-132QS10.241-C1 3-132QS10.241-D1 3-144QS10.301 3-132QS10.481 3-132QS10.481-D1 3-144QS10.DNET 3-132QS20.241 3-132QS20.241-A1 3-132QS20.241-C1 3-132QS20.361 3-132QS20.481 3-132QS40.241 3-132QS40.244 3-132QS40.484 3-132QT20.241 3-134QT20.241-C1 3-134QT20.361 3-134QT20.481 3-134QT40.241 3-134QT40.481 3-134
RR2-2012-23-1012-WTL 1-22R2-2012-23-1024-WTL 1-22R2-2012-23-1048-WTL 1-22R2-2012-23-1110-WTL 1-22R2-2012-23-5012-WTL 1-22R2-2012-23-5024-WTL 1-22R2-2012-23-5048-WTL 1-22R2-2012-23-5110-WTL 1-22R2-2012-23-5240-WTL 1-22R2-2112-23-1024-WTL 1-22R4-2014-23-1012-WTL 1-22R4-2014-23-1024-WTL 1-22R4-2014-23-1048-WTL 1-22R4-2014-23-1110-WTL 1-22R4-2014-23-5012-WTL 1-22R4-2014-23-5024-WTL 1-22R4-2014-23-5048-WTL 1-22R4-2014-23-5110-WTL 1-22R4-2014-23-5240-WTL 1-22R4-2114-23-1024-WTL 1-22R11 2-124R15-2012-23-1012-WTL 1-24R15-2012-23-1024-WTL 1-24R15-2012-23-1048-WTL 1-24R15-2012-23-1110-WTL 1-24R15-2012-23-5012-WTL 1-24R15-2012-23-5024-WTL 1-24R15-2012-23-5048-WTL 1-24R15-2012-23-5110-WTL 1-24R15-2012-23-5240-WTL 1-24R15-2013-23-1012-WTL 1-24R15-2013-23-1024-WTL 1-24R15-2013-23-1048-WTL 1-24R15-2013-23-1110-WTL 1-24R15-2013-23-5012-WTL 1-24R15-2013-23-5024-WTL 1-24
R15-2013-23-5048-WTL 1-24R15-2013-23-5110-WTL 1-24R15-2013-23-5240-WTL 1-24RBIP-01 14-613RC 51/50 14-636RC 51/133 14-636RC 51/250 14-636RC 51/440 14-636RC 52/50 14-636RC 52/133 14-636RC 52/250 14-636RC 52/440 14-636RCAN-01 14-612, 14-613RCNA-01 14-612, 14-613RDNA-01 14-612, 14-613RETA-01 14-612, 14-613RETA-02 14-612, 14-613RF-40RL5 2-66RF-210 2-81RF-410 2-66, 2-82RF-420 2-66, 2-70, 2-75, 2-82RLK39-8-2000-Z/31/40a/116 2-74, 2-77RLK39-55-Z/31/35/40a/116 2-69RLON-01 14-612, 14-613RM84-2012-25-1012 1-20RM84-2012-25-1024 1-20RM84-2012-25-1048 1-20RM84-2012-25-1110 1-20RM84-2012-25-5012 1-20RM84-2012-25-5024 1-20RM84-2012-25-5048 1-20RM84-2012-25-5110 1-20RM84-2012-25-5240 1-20RM84-2312-25-1024 1-20RM87N-2011-25-1012 1-20RM87N-2011-25-1024 1-20RM87N-2011-25-1048 1-20RM87N-2011-25-1110 1-20RM87N-2011-25-5012 1-20RM87N-2011-25-5024 1-20RM87N-2011-25-5048 1-20RM87N-2011-25-5110 1-20RM87N-2011-25-5240 1-20RM87N-2311-25-1024 1-20RM699BV-3011-85-1012 1-29RM699BV-3011-85-1024 1-29RM699BV-3011-85-1060 1-29RM699BV-3211-85-1024 1-29RPBA-01 14-612, 14-613RPM072 15-658RPM075 15-664RSRSTP00 7-403RSS 36-D 6-300RSS 36-D-R 6-300RSS 36-D-R-ST 6-300RSS 36-D-ST 6-300RSS 36-I1-D 6-300RSS 36-I1-D-R 6-300RSS 36-I1-D-R-ST 6-300RSS 36-I1-D-ST 6-300RSS 36-I1-SD-R-ST 6-300RSS 36-I1-SD-ST 6-300RSS 36-I2-D 6-300RSS 36-I2-D-R 6-300RSS 36-I2-D-R-ST 6-300RSS 36-I2-D-ST 6-300RSS 36-I2-SD-R-ST 6-300RSS 36-I2-SD-ST 6-300RSS 36-SD-R-ST 6-300RSS 36-SD-ST 6-300RST 36-1 6-300RST 36-1-R 6-300RT 17-762RT-610-10 2-77, 2-89RT-610-10G 2-77RT-610-10R 2-77RT-610-20 2-77, 2-89RT-610-20G 2-77RT-610-20R 2-77RT-610-50 2-77, 2-89RV 5/50 14-636RV 5/133 14-636RV 5/250 14-636RV 5/440 14-636
SS1-M1-25 14-646S1-M2-25 14-646S2CA1 13-574S2CA2 13-574S2C-DH 13-577S2CH01 13-574S2CH02L 13-574S2CH6R 13-574S2CH10 13-574S2CH11L 13-574S2CH20L 13-574S2C-PD-DS201 13-577S2C-PD-S200 13-577S2CSH6R 13-574S2CUA24AC 13-574S2CUA24DC 13-574S2CUA230AC 13-574S201C 0.5 13-564S201C 1 13-564S201C 1.6 13-564S201C 2 13-564S201C 3 13-564S201C 4 13-564S201C 6 13-564S201C 8 13-564S201C 10 13-564S201C 13 13-564S201C 16 13-564S201C 20 13-564S201C 25 13-564S201C 32 13-564S201C 40 13-564S201C 50 13-564S201C 63 13-564S201K 0.5 13-565S201K 1 13-565S201K 1.6 13-565S201K 2 13-565S201K 3 13-565S201K 4 13-565S201K 6 13-565S201K 8 13-565S201K 10 13-565S201K 13 13-565S201K 16 13-565S201K 20 13-565S201K 25 13-565S201K 32 13-565S201K 40 13-565S201K 50 13-565S201K 63 13-565S201MC 0.5 13-566S201MC 1 13-566S201MC 1.6 13-566S201MC 2 13-566S201MC 3 13-566S201MC 4 13-566S201MC 6 13-566S201MC 8 13-566S201MC 10 13-566S201MC 13 13-566S201MC 16 13-566S201MC 20 13-566S201MC 25 13-566S201MC 32 13-566S201MC 40 13-566S201MC 50 13-566S201MC 63 13-566S201MK 0.5 13-567S201MK 1 13-567S201MK 1.6 13-567S201MK 2 13-567S201MK 3 13-567S201MK 4 13-567S201MK 6 13-567S201MK 8 13-567S201MK 10 13-567S201MK 13 13-567S201MK 16 13-567S201MK 20 13-567S201MK 25 13-567S201MK 32 13-567S201MK 40 13-567S201MK 50 13-567S201MK 63 13-567S202C 0.5 13-564S202C 1 13-564S202C 1.6 13-564S202C 2 13-564S202C 3 13-564S202C 4 13-564S202C 6 13-564S202C 8 13-564
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
S202C 10 13-564S202C 13 13-564S202C 16 13-564S202C 20 13-564S202C 25 13-564S202C 32 13-564S202C 40 13-564S202C 50 13-564S202C 63 13-564S202K 0.5 13-565S202K 1 13-565S202K 1.6 13-565S202K 2 13-565S202K 3 13-565S202K 4 13-565S202K 6 13-565S202K 8 13-565S202K 10 13-565S202K 13 13-565S202K 16 13-565S202K 20 13-565S202K 25 13-565S202K 32 13-565S202K 40 13-565S202K 50 13-565S202K 63 13-565S202MC 0.5 13-566S202MC 1 13-566S202MC 1.6 13-566S202MC 2 13-566S202MC 3 13-566S202MC 4 13-566S202MC 6 13-566S202MC 8 13-566S202MC 10 13-566S202MC 13 13-566S202MC 16 13-566S202MC 20 13-566S202MC 25 13-566S202MC 32 13-566S202MC 40 13-566S202MC 50 13-566S202MC 63 13-566S202MK 0.5 13-567S202MK 1 13-567S202MK 1.6 13-567S202MK 2 13-567S202MK 3 13-567S202MK 4 13-567S202MK 6 13-567S202MK 8 13-567S202MK 10 13-567S202MK 13 13-567S202MK 16 13-567S202MK 20 13-567S202MK 25 13-567S202MK 32 13-567S202MK 40 13-567S202MK 50 13-567S202MK 63 13-567S203C 0.5 13-564S203C 1 13-564S203C 1.6 13-564S203C 2 13-564S203C 3 13-564S203C 4 13-564S203C 6 13-564S203C 8 13-564S203C 10 13-564S203C 13 13-564S203C 16 13-564S203C 20 13-564S203C 25 13-564S203C 32 13-564S203C 40 13-564S203C 50 13-564S203C 63 13-564S203K 0.5 13-565S203K 1 13-565S203K 1.6 13-565S203K 2 13-565S203K 3 13-565S203K 4 13-565S203K 6 13-565S203K 8 13-565S203K 10 13-565S203K 13 13-565S203K 16 13-565S203K 20 13-565S203K 25 13-565S203K 32 13-565S203K 40 13-565S203K 50 13-565S203K 63 13-565S203MC 0.5 13-566S203MC 1 13-566
S203MC 1.6 13-566S203MC 2 13-566S203MC 3 13-566S203MC 4 13-566S203MC 6 13-566S203MC 8 13-566S203MC 10 13-566S203MC 13 13-566S203MC 16 13-566S203MC 20 13-566S203MC 25 13-566S203MC 32 13-566S203MC 40 13-566S203MC 50 13-566S203MC 63 13-566S203MK 0.5 13-567S203MK 1 13-567S203MK 1.6 13-567S203MK 2 13-567S203MK 3 13-567S203MK 4 13-567S203MK 6 13-567S203MK 8 13-567S203MK 10 13-567S203MK 13 13-567S203MK 16 13-567S203MK 20 13-567S203MK 25 13-567S203MK 32 13-567S203MK 40 13-567S203MK 50 13-567S203MK 63 13-567S281C 80 13-568S281C 100 13-568S282C 80 13-568S282C 100 13-568S283C 80 13-568S283C 100 13-568S800AUX 13-575S800AUX/ALT 13-575S800PLL 13-577S800RD 13-577S800RHEEM 13-577S800RHES 13-577S800-RSU-H 13-575S800-SOR24 13-575S800-SOR250 13-575S800-UVR36 13-575S800-UVR250 13-575S802PV-M 32 13-569S802PV-M 63 13-569S802PV-M 125 13-569S802PV-S 10 13-569S802PV-S 13 13-569S802PV-S 16 13-569S802PV-S 20 13-569S802PV-S 25 13-569S802PV-S 32 13-569S802PV-S 40 13-569S802PV-S 50 13-569S802PV-S 63 13-569S802PV-S 80 13-569S802PV-S 100 13-569S802PV-S 125 13-569S803PV-M 32 13-569S803PV-M 63 13-569S803PV-M 125 13-569S803PV-S 10 13-569S803PV-S 13 13-569S803PV-S 16 13-569S803PV-S 20 13-569S803PV-S 25 13-569S803PV-S 32 13-569S803PV-S 40 13-569S803PV-S 50 13-569S803PV-S 63 13-569S803PV-S 80 13-569S803PV-S 100 13-569S803PV-S 125 13-569S804PV-M 32 13-569S804PV-M 63 13-569S804PV-M 125 13-569S804PV-S 10 13-569S804PV-S 13 13-569S804PV-S 16 13-569S804PV-S 20 13-569S804PV-S 25 13-569S804PV-S 32 13-569S804PV-S 40 13-569S804PV-S 50 13-569S804PV-S 63 13-569S804PV-S 80 13-569S804PV-S 100 13-569S804PV-S 125 13-569SA1 13-577, 14-647SA1E 13-577
SA2 13-577, 14-647SA3 13-577, 14-647SD1-100-275 16-686SD1-150-275 16-686SD1-200-275 16-686SD1-250-275 16-686SD3-100-275 16-686SD3-150-275 16-686SD3-200-275 16-686SD3-250-275 16-686SDD1-50-275 16-688SDD1-50-275-A 16-688SDD1-100-275 16-688SDD1-100-275-A 16-688SDD2-10-18-DC 16-689SDD2-10-30-AC 16-689SDD2-10-45-DC 16-689SDD2-32-65-DC 16-689SDD2-50-130-AC 16-689SDD2-50-150-DC 16-689SDD2-100-150-DC 16-689SDD3-50-275 16-688SDD3-50-275-A 16-688SDD3-100-275 16-688SDD3-100-275-A 16-688SDH-100-550 16-691SDH-100-1500 16-691SDH-100-2000 16-691SDH-200-1000 16-691SDN1-50-275 16-687SDN1-100-275 16-687SDN3-50-275 16-687SDN3-100-275 16-687SDN3-150-275 16-687SDN3-200-275 16-687SDPV-40-400 16-690SDPV-40-400-A 16-690SDPV-40-600 16-690SDPV-40-600-A 16-690SDPV-40-800 16-690SDPV-40-800-A 16-690SDPV-40-1000 16-690SDPV-40-1000-A 16-690SDS 1 12-536SE 304C 6-337SE 400C 6-337SE-AL10-1250 6-337SE-AL10-2500 6-337SE-AL20-1250 6-337SE-AL20-2500 6-337SEP 01.0.1.0.22/95 6-334SEP 01.0.L.22 6-334SE-P40-1250 6-337SE-P40-2500 6-337SE-P40-5000 6-337SE-P40-10000 6-337SE-P70-1250 6-337SE-P70-2500 6-337SE-P70-5000 6-337SE-P70-10000 6-337SEPK 02.0.4.0.22/95 6-334SEPK 02.0.L.22 6-334SER-485-FXC 10-483SER-485-IR 11-501SERIAL-DB9-M12 10-475SERIAL-DB9-RM12 10-475SE-SET VER.2.0 6-337SE-T40 6-337SE-T70 6-337SF921R2021 12-534SF921R2022 12-534SF921R2023 12-534SF921R2024 12-534SF921R2025 12-534SF921R2221 12-534SF921R2222 12-534SF921R2223 12-534SF921R2224 12-534SF921R2225 12-534SFD1-2-2-30-C 16-715SFD1-2-6.5-50-C 16-715SFD1-2-6.5-130-C 16-715SFD1-2-6.5-275 16-700, 16-715SFD1-6-2-30-C 16-715SFD1-6-6.5-50-C 16-715SFD1-6-6.5-130-C 16-715SFD1-6-6.5-275 16-700, 16-715SFD1-10-50-275 16-700SFD1-10-50-275-A 16-700SFD1-20-50-275 16-700SFD1-20-100-275-A 16-700SFD1-32-50-275-A 16-700SFD1-32-100-275-A 16-700SFD3-10-50-275-A 16-701SFD3-20-50-275-A 16-701SFH3-250-100-275 16-696
SFH3-250-200-275 16-696SFH3-400-100-275 16-696SFH3-400-200-275 16-696SFH3-630-100-275 16-696SFH3-630-200-275 16-696SFH3-800-100-275 16-696SFH3-800-200-275 16-696SFH3-1200-100-275 16-697SFH3-1200-200-275 16-697SFH3-1600-100-275 16-697SFH3-1600-200-275 16-697SFH3-2000-100-275 16-697SFH3-2000-200-275 16-697SFM1-40-50-275 16-698SFM1-40-100-275 16-698SFM1-63-50-275 16-698SFM1-63-100-275 16-698SFM1-125-50-275 16-699SFM1-125-100-275 16-699SFM3-40-50-275 16-698SFM3-40-100-275 16-698SFM3-63-50-275 16-698SFM3-63-100-275 16-698SFM3-125-50-275 16-699SFM3-125-100-275 16-699SFS2-L-DC24V 6-325SFS3-L-DC24V 6-325SFS4-L-DC24V 6-325SFS4-SFD 6-325SFS5-L-DC24V 6-325SFS6-L-DC24V 6-325SFS6-SFD 6-325SG1-50-255 16-692SG1-110-275 16-692SG3-50-255 16-692SG3-110-275 16-692SGN-100-275 16-692SHRLPAX0 4-231SIP-110 16-731SIP-230 16-731SK4-11 14-644S-K4P-M12-S-G-X-X-X-X-A 2-94, 2-98S-K4P-M12-S-W-X-X-X-X-A-1 2-94, 2-98SK 615.546-2 12-535SK 615.562-88 12-531, 12-535SL-2ES-2XX 10-483SL-2ES-3XX 10-483SL-2ES-3XX-L 10-483SL-5ES-1 10-460SL-5ES-2XX 10-460SL-5ES-3XX 10-460SL-6ES-4XX 10-460SL-6ES-5XX 10-460SL-6RS-1 10-460SL7v5 16-706SL7v5-EC90 16-706SL7v5-G 16-705, 16-706SL-8ES-1 10-460SL-9ES-2XX 10-460SL-9ES-3XX 10-460SL18 16-706SL18-EC90 16-706SL18-G 16-705, 16-706SL36 16-706SL36-EC90 16-705, 16-706SL36-G 16-705, 16-706SL68 16-706SL68-EC90 16-706SL68-G 16-706SL-420 16-707SL-420-G 16-707SL420-G 16-705SL485-EC90 16-705, 16-707SLC 420-E/R0170-14-69-RFB 6-329SLC 420-E/R0170-30-69-RFB 6-329SLC 420-E/R0170-xx-69-RFB 6-330SLC 420-E/R0250-14-69-RFB 6-329SLC 420-E/R0250-30-69-RFB 6-329SLC 420-E/R0250-xx-69-RFB 6-330SLC 420-E/R0330-14-69-RFB 6-329SLC 420-E/R0330-30-69-RFB 6-329SLC 420-E/R0330-xx-69-RFB 6-330SLC 420-E/R0410-14-69-RFB 6-329SLC 420-E/R0410-30-69-RFB 6-329SLC 420-E/R0410-xx-69-RFB 6-330SLC 420-E/R0490-14-69-RFB 6-329SLC 420-E/R0490-30-69-RFB 6-329SLC 420-E/R0490-xx-69-RFB 6-330SLC 420-E/R0570-14-69-RFB 6-329SLC 420-E/R0570-30-69-RFB 6-329SLC 420-E/R0570-xx-69-RFB 6-330SLC 420-E/R0650-14-69-RFB 6-329SLC 420-E/R0650-30-69-RFB 6-329SLC 420-E/R0650-xx-69-RFB 6-330SLC 420-E/R0730-14-69-RFB 6-329SLC 420-E/R0730-30-69-RFB 6-329
779
Product Code Index
SLC 420-E/R0730-xx-69-RFB 6-330SLC 420-E/R0810-14-69-RFB 6-329SLC 420-E/R0810-30-69-RFB 6-329SLC 420-E/R0810-xx-69-RFB 6-330SLC 420-E/R0890-14-69-RFB 6-329SLC 420-E/R0890-30-69-RFB 6-329SLC 420-E/R0890-xx-69-RFB 6-330SLC 420-E/R0970-14-69-RFB 6-329SLC 420-E/R0970-30-69-RFB 6-329SLC 420-E/R0970-xx-69-RFB 6-330SLC 420-E/R1050-14-69-RFB 6-329SLC 420-E/R1050-30-69-RFB 6-329SLC 420-E/R1050-xx-69-RFB 6-330SLC 420-E/R1130-14-69-RFB 6-329SLC 420-E/R1130-30-69-RFB 6-329SLC 420-E/R1130-xx-69-RFB 6-330SLC 420-E/R1210-14-69-RFB 6-329SLC 420-E/R1210-30-69-RFB 6-329SLC 420-E/R1210-xx-69-RFB 6-330SLC 420-E/R1290-30-69-RFB 6-329SLC 420-E/R1290-xx-69-RFB 6-330SLC 420-E/R1370-14-69-RFB 6-329SLC 420-E/R1370-30-69-RFB 6-329SLC 420-E/R1370-xx-69-RFB 6-330SLC 420-E/R1450-14-69-RFB 6-329SLC 420-E/R1450-30-69-RFB 6-329SLC 420-E/R1450-xx-69-RFB 6-330SLC 420-E/R12910-14-69-RFB 6-329SLC 440-E/R0170-14-01 6-326SLC 440-E/R0170-30-01 6-326SLC440-ER-0170-XX 6-327SLC 440-E/R0250-14-01 6-326SLC 440-E/R0250-30-01 6-326SLC440-ER-0250-XX 6-327SLC 440-E/R0330-14-01 6-326SLC 440-E/R0330-30-01 6-326SLC440-ER-0330-XX 6-327SLC 440-E/R0410-14-01 6-326SLC 440-E/R0410-30-01 6-326SLC440-ER-0410-XX 6-327SLC 440-E/R0490-14-01 6-326SLC 440-E/R0490-30-01 6-326SLC440-ER-0490-XX 6-327SLC 440-E/R0570-14-01 6-326SLC 440-E/R0570-30-01 6-326SLC440-ER-0570-XX 6-327SLC 440-E/R0650-14-01 6-326SLC 440-E/R0650-30-01 6-326SLC440-ER-0650-XX 6-327SLC 440-E/R0730-14-01 6-326SLC 440-E/R0730-30-01 6-326SLC440-ER-0730-XX 6-327SLC 440-E/R0800-03-01 6-328SLC 440-E/R0810-14-01 6-326SLC 440-E/R0810-30-01 6-326SLC440-ER-0810-XX 6-327SLC 440-E/R0890-14-01 6-326SLC 440-E/R0890-30-01 6-326SLC440-ER-0890-XX 6-327SLC 440-E/R0900-04-01 6-328SLC 440-E/R0970-14-01 6-326SLC 440-E/R0970-30-01 6-326SLC440-ER-0970-XX 6-327SLC 440-E/R1050-14-01 6-326SLC 440-E/R1050-30-01 6-326SLC440-ER-1050-XX 6-327SLC 440-E/R1130-14-01 6-326SLC 440-E/R1130-30-01 6-326SLC440-ER-1130-XX 6-327SLC 440-E/R1210-14-01 6-326SLC 440-E/R1210-30-01 6-326SLC440-ER-1210-XX 6-327SLC440-ER-1290-XX 6-327SLC440-ER-1370-XX 6-327SLC440-ER-1450-XX 6-327SLC440-ER-1530-XX 6-327SLC440-ER-1610-XX 6-327SLC440-ER-1690-XX 6-327SLC440-ER-1770-XX 6-327SL-COMB 16-706, 16-707, 16-708SLD1-7v5 16-709SLD1-18 16-709SLD1-36 16-709SLD1-68 16-709SLD1-DH 16-709SLD1-PSTN 16-709SLD1-RS485 16-709SLD2-7v5 16-709SLD2-18 16-709SLD2-36 16-709SLD2-68 16-709SLD2-DH 16-709SLD2-PSTN 16-709SLD2-RS485 16-709SLD4-7v5 16-709SLD4-18 16-709
SLD4-36 16-709SLD4-68 16-709SLD4-DH 16-709SLD4-PSTN 16-709SLD4-RS485 16-709SL-DH 16-704, 16-705, 16-707SL-DH-EC90 16-705, 16-707SLDIN-EC90 16-706, 16-707, 16-708SLDIN-G 16-706, 16-707, 16-708SLG 440-E/R0500-02-01 6-328SLG440-ER-0500-02-01 6-328SLG440-ER-0800-03-01 6-328SLG440-ER-0900-04-01 6-328SL-iSwitch 16-706SL-iSwitch-EC90 16-706SL-iSwitch-G 16-706SLM-7v5 16-710SLM-18 16-710SLM-36 16-710SLM-68 16-710SLM-200 16-710SL-PSTN 16-706SL-PSTN-EC90 16-706SL-PSTN-G 16-706SL-PTSN-G 16-705SL-RTD 16-707SL-RTD-G 16-707SLT-Y-M20 16-729SLT-Y-N12 16-729SLT-Y-N34 16-729SLX-5ES-1 10-462SLX-5ES-2XX 10-462SLX-5ES-3XX 10-462SLX-5ES-3XXL 10-462SLX-5MS-1 10-465SLX-5MS-4XX 10-465SLX-5MS-5XX 10-465SLX-5MS-5XXL 10-465SLX-6ES-4XX 10-462SLX-6ES-5XX 10-462SLX-6ES-5XXL 10-462SLX-6RS-1 10-462, 10-465SLX-8ES-1 10-462SLX-8ES-6XX 10-462SLX-8ES-7XX 10-462SLX-8ES-7XXL 10-462SLX-8MG-1 10-465SLX-8MS-1 10-465SLX-8MS-4XX 10-465SLX-8MS-5XX 10-465SLX-8MS-5XXL 10-465SLX-8MS-8XX 10-465SLX-8MS-9XX 10-465SLX-8MS-9XXL 10-465SLX-9ES-2XX 10-462SLX-9ES-3XX 10-462SLX-9ES-3XXL 10-462SLX-10MG-1 10-465SLX-16MS-1 10-465SLX-18MG-1 10-465SMS 4 250-500 6-336SMS 4 500-500 6-336SMS 4 500-1000 6-336SMS 4 750-1000 6-336SMS 4 1000-1000 6-336SMS 4 1000-1500 6-336SMS 4-BS-3000 6-336SMS 4-EV 6-336SMS 4-RS-3000 6-336SN201-IH 13-574SN201S 13-574SN-6801EB-GE 10-480SN-6801-GE 10-480SN-6821-GE 10-480SN-SVM-25 10-482SN-SVM-UL 10-482Spacer BN 31 6-295Spacer BN 33 6-295Spacer BNS 250 6-296Spacer BNS 260 6-297SPE1 13-579SRB 200 EXI-1A 6-324SRB 200 EXI-1R 6-324SRB 201 LC 6-315SRB 201ZH 24VDC 6-320SRB 202 MSL 6-323SRB 207 AN-24VDC 6-314SRB 207 AN-230VDC 6-314SRB 301 AN 24VAC/DC 6-314SRB 301 HC/R 6-320SRB 301HC/R 6-321SRB 301HC/T 6-321SRB 301 LC 6-315SRB 301 MA 6-316SRB 301MC 6-316SRB 301 MC 24 VAC/DC 6-316
SRB 301 ST V.2 24 VAC/DC 6-317SRB 401EM-230V 6-318SRB 402EM 6-318SRN3215K 12-541SRN3315K 12-541SRN4320K 12-541SRN4420K 12-541SRN5425K 12-541SRN6420K 12-541SRN6625K 12-541SRN7525K 12-541SRN8630K 12-541SRN10630K 12-541SRN10830K 12-541SRN12630K 12-541SRN12830K 12-541SSP1-6-6.5-275 16-694SSP1-10-6.5-275 16-694SSP1-20-50-275 16-694SSP1-20-100-275 16-694SSP1-32-50-275 16-694SSP1-32-100-275 16-694SSP1-63-50-275 16-694SSP1-63-100-275 16-694SSP3-20-50-275-A 16-695SSP3-20-100-275-A 16-695SSP3-32-50-275-A 16-695SSP3-32-100-275-A 16-695SSP3-63-50-275-A 16-695SSP3-63-100-275-A 16-695SSP6A-14 16-708SSP6A-14-EC90 16-708SSP6A-14-G 16-708SSP6A-26 16-708SSP6A-26-EC90 16-708SSP6A-26-G 16-708SSP6A-38 16-705, 16-708SSP6A-38-EC90 16-708SSP6A-38-G 16-705, 16-708SSP6A-65 16-708SSP6A-65-EC90 16-708SSP6A-65-G 16-708SSP6A-130 16-708SSP6A-130-EC90 16-708SSP6A-130-G 16-708ST-121F 7-397ST-122F 7-397ST-131F 7-397ST-221F 7-397ST-222F 7-397ST-1114 7-397ST-1124 7-397ST-1214 7-397ST-1218 7-397ST-1224 7-397ST-1228 7-397ST-1314 7-397ST-1324 7-397ST-1804 7-397ST-1904 7-397ST-2114 7-397ST-2124 7-397ST-2314 7-397ST-2318 7-397ST-2324 7-397ST-2328 7-397ST-2414 7-397ST-2424 7-397ST-2514 7-397ST-2524 7-397ST-2614 7-397ST-2624 7-397ST-2742 7-397ST-2744 7-397ST-2748 7-397ST-2792 7-397ST-2852 7-397ST-3114 7-397ST-3118 7-397ST-3134 7-397ST-3214 7-397ST-3218 7-397ST-3234 7-397ST-3274 7-397ST-3424 7-397ST-3428 7-397ST-3444 7-397ST-3524 7-397ST-3544 7-397ST-3624 7-397ST-3644 7-397ST-3702 7-397ST-3704 7-397ST-3708 7-397ST-3714 7-398ST-3734 7-398
ST-3802 7-397ST-3804 7-397ST-3808 7-397ST-3814 7-398ST-3834 7-398ST-4112 7-398ST-4114 7-398ST-4212 7-398ST-4214 7-398ST-4274 7-398ST-4422 7-398ST-4424 7-398ST-4474 7-398ST-4491 7-398ST-4522 7-398ST-4622 7-398ST-4911 7-398ST-5101 7-398ST-5111 7-398ST-5112 7-398ST-5114 7-398ST-5211 7-398ST-5212 7-398ST-5221 7-398ST-5231 7-398ST-5232 7-398ST-5252 7-398ST-5272 7-398ST-5351 7-398ST-5422 7-398ST-5442 7-398ST-5444 7-398ST-5641 7-398ST-5642 7-398ST-5651 7-398ST-5725 7-399ST-5726 7-399ST-7008 7-399ST-7108 7-399ST-7111 7-399ST-7118 7-399ST-7188 7-399ST-7241 7-399ST-7408 7-399ST-7508 7-399ST-7511 7-399ST-7518 7-399ST-7588 7-399ST-7641 7-399STACKCBL30 10-472STACKCBL130 10-472STXACC001 7-399STXACC002 7-399STXACC004 7-399STXCAN001 7-396STXCCL001 7-396STXDNS001 7-396STXECT001 7-396STXEIP001 7-396STXMBE001 7-396STXMBS001 7-396STXMBS002 7-396STXPBS001 7-396STXPBS016 7-399STXPBS032 7-399STXPBS116 7-399STXPBS132 7-399STXPBS232 7-399STXPBS332 7-399STXPBS432 7-399STXPBS532 7-399STXPBS824 7-399STXPBS825 7-399STXPBS924 7-399STXPBS925 7-399STXPNS001 7-396STXRTB009 7-399SVC77U031036 13-601SX-1131-S-1K 7-393SX-1131-S-32 7-393SX-1131-S-256 7-393SX-1131-S-BIG 7-393SXIPM-AGA-1 7-392SXIPM-DNP3-1 7-392SXIPM-IEC870-1 7-392SXIPM-PPP-1 7-392SXIPM-SAFE 7-392SXIPM-SNMP 7-392SXTOOLS-1 7-392SXTOOLS-2 7-392SXTOOLS-3 7-392SXTOOLS-4 7-392SXTOOLS-5 7-392SXTOOLS-P 7-392
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexProduct Code Index
TT2L 035-11Z 2-58T3C 235-11Z-M20 6-310T3C 236-11Z-M20 6-310T3Z 068-11YR 6-333T3Z 068-22YR 6-333T4C 235-11Z-M20 6-310T4C 236-11Z-M20 6-310T5C 235-11Z-M20 6-310T5C 236-11Z-M20 6-310T 250-11Z-1224 2-62T 250-22Z-1224 2-62T 441-11Y-14 2-63T.441-11Y-243 2-63T.441-11Y-966 2-63T.441-11Y-1224 2-63T1610000 4-193T1610010 4-193T1611100 4-193T1611110 4-193T1620000 4-193T1620010 4-193T1621100 4-193T1621110 4-193T1641100 4-193T1641110 4-193T4810000 4-195T4810101 4-195T4810105 4-195T4810107 4-195T4810111 4-195T4810115 4-195T4810117 4-195T4811100 4-195T4811110 4-195T4820205 4-195T4820208 4-195T4820211 4-195T4820215 4-195T4820218 4-195T4821100 4-195T4821110 4-195TA 25 DU0.4 14-640TA 25 DU0.16 14-640TA 25 DU0.25 14-640TA 25 DU0.63 14-640TA 25 DU1.0 14-640TA 25 DU1.4 14-640TA 25 DU1.8 14-640TA 25 DU2.4 14-640TA 25 DU3.1 14-640TA 25 DU4.0 14-640TA 25 DU5.0 14-640TA 25 DU6.5 14-640TA 25 DU8.5 14-640TA 25 DU11 14-640TA 25 DU14 14-640TA 25 DU19 14-640TA 25 DU25 14-640TA 25 DU32 14-640TA 42 DU25 14-640TA 42 DU32 14-640TA 42 DU42 14-640TA 75 DU25 14-640TA 75 DU32 14-640TA 75 DU42 14-640TA 75 DU52 14-640TA 75 DU63 14-640TA 75 DU80 14-640TA 80 DU42 14-640TA 80 DU52 14-640TA 80 DU63 14-640TA 80 DU80 14-640TA 110 DU90 14-640TA 110 DU110 14-640TA 200 DU90 14-640TA 200 DU110 14-640TA 200 DU135 14-640TA 200 DU150 14-640TA 200 DU175 14-640TA 200 DU200 14-640TA 450 DU185 14-640TA 450 DU235 14-640TA 450 DU310 14-640TA 450 DU400 14-640TAA0811K0X05 15-673TAA1211K0X05 15-674TAA1211K2X05 15-674TAA1211K5X05 15-674TAA1611K0X05 15-674TAA1611K5X05 15-674TAA1612K0X05 15-674TAA1612K5X05 15-674TAA1613K0X05 15-674
TAA1614K0X05 15-674TAA1615K0X05 15-674TAA031100X05 15-673TAA031150X05 15-673TAA031200X05 15-673TAA031400X05 15-673TAA081250X05 15-673TAA081400X05 15-673TAA081500X05 15-673TAA081600X05 15-673TAA081800X05 15-673TAA121800X05 15-674TAC0401K0X05 15-670TAC032040X05 15-669TAC032050X05 15-669TAC032060X05 15-669TAC032080X05 15-669TAC032100X05 15-669TAC032120X05 15-669TAC032150X05 15-669TAC032200X05 15-669TAC032250X05 15-669TAC032300X05 15-669TAC032400X05 15-669TAC032500X05 15-669TAC032600X05 15-669TAC040100X05 15-670TAC040120X05 15-670TAC040150X05 15-670TAC040200X05 15-670TAC040250X05 15-670TAC040300X05 15-670TAC040400X05 15-670TAC040500X05 15-670TAC040600X05 15-670TAC040800X05 15-670TAT0611K0X05 15-671TAT0841K0X05 15-671TAT0841K2X05 15-671TAT0841K5X05 15-671TAT0842K5X05 15-671TAT1251K0X05 15-672TAT1251K2X05 15-672TAT1251K5X05 15-672TAT1252K0X05 15-672TAT1252K5X05 15-672TAT1253K0X05 15-672TAT1254K0X05 15-672TAT1261K0X05 15-672TAT1261K2X05 15-672TAT1261K5X05 15-672TAT1262K0X05 15-672TAT1262K5X05 15-672TAT1263K0X05 15-672TAT1264K0X05 15-672TAT022040X05 15-669TAT022050X05 15-669TAT022060X05 15-669TAT022080X05 15-669TAT022100X05 15-669TAT022120X05 15-669TAT022150X05 15-669TAT022200X05 15-669TAT022250X05 15-669TAT022300X05 15-669TAT022400X05 15-669TAT022500X05 15-669TAT022600X05 15-669TAT061250X05 15-671TAT061300X05 15-671TAT061400X05 15-671TAT061500X05 15-671TAT061600X05 15-671TAT061800X05 15-671TAT084200X05 15-671TAT084250X05 15-671TAT084300X05 15-671TAT084400X05 15-671TAT084500X05 15-671TAT084600X05 15-671TAT084800X05 15-671TAT125400X05 15-672TAT125500X05 15-672TAT125600X05 15-672TAT125800X05 15-672TAT126400X05 15-672TAT126500X05 15-672TAT126600X05 15-672TAT126800X05 15-672TB100003 1-43, 4-178TB100004 1-43, 4-178TB100005 1-43, 4-178TB5560187N 1-42TB5590185N 1-42TB5630187N 1-42TB5640185N 1-42
TD 250-02/02Z 2-58TD 250-02Z 2-58TD 250-11Z 2-58TESF-14 6-311TESF/S 6-311TESF/U 6-311TES/S 6-311TESZ1102 6-311TESZ1102/S 6-311TF42-0.13 14-641TF42-0.17 14-641TF42-0.23 14-641TF42-0.31 14-641TF42-0.41 14-641TF42-0.55 14-641TF42-0.74 14-641TF42-1.0 14-641TF42-1.3 14-641TF42-1.7 14-641TF42-2.3 14-641TF42-3.1 14-641TF42-4.2 14-641TF42-5.7 14-641TF42-7.6 14-641TF42-10 14-641TF42-13 14-641TF42-16 14-641TF42-20 14-641TF42-24 14-641TF42-29 14-641TF42-35 14-641TF42-38 14-641TFH 232-11 6-338TFH 232-11UEDR 6-338TFH 232-22 6-338TFH 232-22UEDR 6-338TH144 1-45TH144S 1-45TH145 1-45TH145S 1-45TH146 1-45TH146S 1-45TH149 1-45TH149S 1-45TH244 1-45TH244S 1-45TH245 1-45TH245S 1-45TH246 1-45TH246S 1-45TH249 1-45TH249S 1-45TH404 1-45TH404S 1-45TH405 1-45TH405S 1-45TH406 1-45TH406S 1-45TH409 1-45TH409S 1-45TH504 1-46TH504S 1-46TH505 1-46TH505S 1-46TH506 1-46TH506S 1-46TH509 1-46TH509S 1-46TH634 1-46TH635 1-46TH636 1-46TH639 1-46TH644 1-46TH645 1-46TH646 1-46TH649 1-46TH703 1-47TH703S 1-47TH704 1-47TH704S 1-47TH833C 1-47TH834C 1-47TK-M5 6-301, 6-307TKO 2.5/2-AVK 2.5 17-744TKO 2.5/3-AVK 2.5 17-744TKO 2.5/10-AVK 2.5 17-744TKO 4/2-AVK 4 17-744TKO 4/3-AVK 4 17-744TKO 4/10-AVK 4 17-744TKO 6/2 17-751TKO 6/2-AVK 6 17-744TKO 6/3 17-751TKO 6/3-AVK 6 17-744TKO 6/4 17-751TKO 6/10 17-751TKO 6/10-AVK 6 17-744
TKO 10/2 17-751TKO 10/2-AVK 10 17-744TKO 10/3 17-751TKO 10/3-AVK 10 17-744TKO 10/4 17-751TKO 10/10 17-751TKO 10/10-AVK 10 17-744TP 40 DA 14-635TP 40 IA 14-635TP 180 DA 14-635TP 180 IA 14-635TQ 441-01/01UE-RS-M20 2-59TQ 441-01/01Y-UE-M20 2-59TQ 441-01/01Y-UE-R-M20 2-59TQ 700-02 2-60TQ 700-11 2-60TQ 700-20 2-60TQ 900-02 2-61TQ 900-04 2-61TQ 900-11 2-61TQ 900-13 2-61TQ 900-22 2-61TR1E2R60360V1HVG2STIP64 2-119TR1E2R60500V1HVG2STIP64 2-119TR1E2R61000V1HVG2STIP64 2-119TR1E2R62500V1HVG2STIP64 2-119TR3K3B0360V1HVG2STIP66 2-119TR3K3B0500V1HVG2STIP66 2-119TR3K3B1000V1HVG2STIP66 2-119TR3K3B2500V1HVG2STIP66 2-119TR3R3B0360V1HVG2STIP66 2-119TR3R3B0500V1HVG2STIP66 2-119TR3R3B1000V1HVG2STIP66 2-119TR3R3B2500V1HVG2STIP66 2-119TR12KR60360V1HVG2STIP64 2-119TR12KR60500V1HVG2STIP64 2-119TR12KR61000V1HVG2STIP64 2-119TR12KR62500V1HVG2STIP64 2-119TSC1-DIN 16-735TSC1-DIN-EC 16-735TSC1-IP65 16-735TT2015K 12-541TT3015K 12-541TT3020K 12-541TT4020K 12-541TT4025K 12-541TT6025K 12-541TT6030K 12-541TT8030K 12-541TV10S 335-02Z-M20 6-310TV10S 335-11Z-M20 6-310TZQ-10KIT 2-59, 2-61, 2-60, 6-331, 6-332, 6-333TZQ-20KIT 2-61, 6-332TZQ-30KIT 2-59TZQ-50KIT 2-61, 6-332, 6-333
UUA4-24 14-644UA4-110 14-644UA4-230 14-644UA4-400 14-644UA4-HK-230 14-644UA4-HK-400 14-644UB10.241 3-141UB10.242 3-141UB10.245 3-141UB20.241 3-141UBC10.241-N1 3-141UC10.241 3-139UC10.242 3-139UC300-F43-2KIR2-V17 2-110UC500-30GM-E6R2-V15 2-110UC500-30GM-IUR2-V15 2-110UC2000-30GM-E6R2-V15 2-110UC2000-30GM-IUR2-V15 2-110UC2000-F43-2KIR2-V17 2-110UC4000-30GM-E6R2-V15 2-110UC4000-30GM-IUR2-V15 2-110UC6000-30GM-E6R2-V15 2-110UC6000-30GM-IUR2-V15 2-110UF20.241 3-139UF20.481 3-139UK 1.5/2-PYK 1.5 17-755UK 1.5/3-PYK 1.5 17-755UK 1.5/10-PYK 1.5 17-755UK 2.5/2-AVK 2.5 17-744, 17-747, 17-750UK 2.5/2-PUK3 17-748, 17-749UK 2.5/2-PYK 2.5 17-755UK 2.5/2-YBK 2.5 17-756, 17-757, 17-758, 17-760UK 2.5/3 2-AVK 2.5 17-744, 17-747, 17-750UK 2.5/3 2-PUK3 17-748, 17-749
781
Product Code Index
UK 2.5/3 2-YBK 2.5 17-757, 17-758, 17-760UK 2.5/3-PYK 2.5 17-755UK 2.5/10 2-AVK 2.5 17-744, 17-747, 17-750UK 2.5/10 2-PUK3 17-748, 17-749UK 2.5/10 2-YBK 2.5 17-757, 17-758, 17-760UK 2.5/10-PYK 2.5 17-755UK 4/2-AVK 4 17-744, 17-747, 17-750UK 4/2-PYK 4 17-755, 17-760UK 4/2-YBK 4/ASK 3 17-752UK 4/3-AVK 4 17-744, 17-747, 17-750UK 4/3-PYK 4 17-755, 17-760UK 4/3-YBK 4/ASK 3 17-752UK 4/4-YBK 4/ASK 3 17-752UK 4/10-AVK 4 17-744, 17-747, 17-750UK 4/10-PYK 4 17-755, 17-760UK 6/2-AVK 6 17-744, 17-750UK 6/2-PYK 6 17-755UK 6/2-YBK 6 17-759UK 6/3 2-YBK 6 17-759UK 6/3-AVK 6 17-744, 17-750UK 6/3-PYK 6 17-755UK 6/10 2-YBK 6 17-759UK 6/10-AVK 6 17-744, 17-750UK 6/10-PYK 6 17-755UK 10/2-AVK 10 17-744, 17-747UK 10/2-PYK 10 17-755UK 10/3-AVK 10 17-744, 17-747UK 10/3-PYK 10 17-755UK 10/10-AVK 10 17-744, 17-747UK 10/10-PYK 10 17-755UK 16/2-AVK 16 17-744UK 16/3-AVK 16 17-744UK 16/10-AVK 16 17-744UK 35/2-AVK 35 17-744UK 35/3-AVK 35 17-744UK 35/10-AVK 35 17-744UK 50/2-AVK50 17-745UK 50/3-AVK50 17-745UK 50/4-AVK50 17-745UK 70/2-AVK70 17-745UK 70/3-AVK70 17-745UK 70/4-AVK70 17-745UK 95/2-AVK95 17-745UK 95/3-AVK95 17-745UK 95/4-AVK95 17-745UK 150/2-AVK150 17-745UK 150/3-AVK150 17-745UK 150/4-AVK150 17-745UK 240/2-AVK240 17-745UK 240/3-AVK240 17-745UK 240/4-AVK240 17-745UKB 95/2-AVK95B 17-746UKB 95/3-AVK95B 17-746UKB 95/4-AVK95B 17-746UKB 150/2-AVK150B 17-746UKB 150/3-AVK150B 17-746UKB 150/4-AVK150B 17-746UKB 240/2-AVK240B 17-746UKB 240/3-AVK240B 17-746UKB 240/4-AVK240B 17-746UTP-RJ45-1CAT6 16-716UTP-RJ45-1PoE 16-716UTP-RJ45-8CAT6 16-716UTP-RJ45-8PoE 16-716UTP-RJ45-16CAT6 16-716UTP-RJ45-16PoE 16-716UTP-RJ45-24CAT6 16-716UTP-RJ45-24PoE 16-716UTP-RJ45-xCAT6 16-705UTP-RJ45-xPoE 16-705UZO12.07 3-142UZO12.26 3-142UZO24.071 3-142UZO24.121 3-142UZS24.100 3-142
VV1-G-2M-PVC 2-67, 2-71, 2-75, 2-96V1-G-5M-PVC 2-67, 2-71, 2-75, 2-96V1-W-2M-PVC 2-67, 2-71, 2-75, 2-96V1-W-5M-PVC 2-67, 2-71, 2-75, 2-96V15-G-2M-PVC 2-110V15-G-5M-PVC 2-110V15-W-2M-PVC 2-110V15-W-5M-PVC 2-110V17-G-2M-PUR 2-110V17-G-5M-PUR 2-110V17-W-2M-PUR 2-110V17-W-5M-PUR 2-110VC77U03536 13-601VC77U03636 13-601
VE 51 14-636VE 52 14-636VEM4 14-636, 14-639VF-D500-3 2-74VF-D500T-3 2-74VF-D1000-3 2-74VF-D1000T-3 2-74VF-M10-3 2-77VF-M10T-3 2-77VF-PRM3-3 2-69VF-RM5-3 2-69VF-RM5T-3 2-69VM4 14-639VM 51 14-636VM 300/460H 14-637VM 300/460V 14-637VM 300H 14-637VM 300V 14-637VM 750H 14-637VM 750V 14-637VM1650H 14-637VMICBL-000-F5-0xx 7-382VT-IPM2M-113-D 7-390VT-IPM2M-213-D 7-390VT-MIPM-135-D 7-390VT-MIPM-245-D 7-390VT-MODEM-5WW 10-483VT-UIPM-431-H 7-390
WWB 75A** 14-636WGO 2N GREY DOUBLE SOCKET 17-751WGO 3 GREY DOUBLE SOCKET 17-751WGO UAA 17-751WRA 12-30 xxx 14-649WRA 16-30 xxx 14-649WRA 30-30 xxx 14-649WRB 6-30 xxx 14-649WSD220 13-578WSD232 13-578WSD245 13-578WSD263 13-578WSD420 13-578WSD432 13-578WSD445 13-578WSD463 13-578
xXAC0401K0XMO 15-676XAC032050XMO 15-676XAC032100XMO 15-676XAC032150XMO 15-676XAC032250XMO 15-676XAC032400XMO 15-676XAC032600XMO 15-676XAC040400XMO 15-676XAC040600XMO 15-676x|act ci 5-235, 5-267x|act i 5-235, 5-266XCBDP00 11-495XCCN0000 4-225, 7-401, 11-493, 11-494, 11-495, 11-496XCDN0000 4-225, 7-401, 11-493, 11-494, 11-495, 11-496XCENET00 4-225, 7-401, 11-493, 11-494, 11-495, 11-496XCGSM000 4-225, 7-401, 11-494, 11-495, 11-496XCPBDP00 4-225, 7-401, 11-493, 11-494, 11-496XCRS0000 4-225, 7-401, 11-493, 11-494, 11-495, 11-496XLP 00 13-596, 13-597XLP 00-A60/60 13-597XLP 1 13-596, 13-597XLP 1-A60/85 13-597XLP 2 13-596, 13-597XLP 3 13-596, 13-597XMD 5-273XMP ci 5-235, 5-265XMP i 5-235, 5-264
YYASDA7 13-584YASDA8 13-588YASDA28 13-588YAST1 13-587YR2.DIODE 3-136YR40.241 3-136YR40.242 3-136
YR40.245 3-136YR80.241 3-136YR80.242 3-136YRA 9-30 xxx 14-649YRA 12-30 xxx 14-649YRA 16-30 xxx 14-649YRA 26-30 xxx 14-649YRA 40-30 xxx 14-649YRA 50-30 xxx 14-649YRA 63-30 xxx 14-649YRA 95-30 xxx 14-649YRM2.DIODE 3-136
ZZ3K 235-11Z-M20 2-52Z3K 236-11Z-M20 2-51Z3K 335-11Z-M20 2-55Z3K 336-11Z-M20 2-54Z4K 235-11Z-M20 2-52Z4K 236-11Z-M20 2-51Z4V7H 335-11Z-M20-2138 2-55Z4V7H 336 -11Z-M20-2138 2-54Z4V10H 335-11Z-M20 2-55Z4V10H 336-11Z-M20 2-54Z4VH 335-11Z-M20 2-55Z4VH 336-11Z-M20 2-54ZG20-1 1-29ZG20-2 1-29ZG20-3 1-29ZGGZ4 1-23ZGGZ80 1-20, 1-21ZQ 700-02 6-331ZQ 700-11 6-331ZQ 900-02 6-332ZQ 900-02N 6-332ZQ 900-11 6-332ZQ 900-11N 6-332ZQ 900-22 6-332ZQ 900-22N 6-332ZR 235-11Z-M20 2-52ZR 236-11Z-M20 2-51ZR 335-11Z-M20 2-55ZR 336-11Z-M20 2-54ZS 235 -11Z-M20 2-52ZS 236 -11Z-M20 2-51ZS 335-11Z-M20 2-55ZS 336-11Z-M20 2-54ZSD 5/0.LTG 6-335ZSD 6/0.LTG 6-335ZV1H 235-11Z-M20 2-52ZV1H 236-11Z-M20 2-51ZV7H 235-11Z-M20-2138 2-52ZV7H 236-11Z-M20-2138 2-51ZV10H 235-11Z-M20 2-52ZV10H 236-11Z-M20 2-51ZV12H 235-11Z-M20 2-52ZV12H 236-11Z-M20 2-51
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
indexTerms and Conditions of Sale
1. GOOdS And SeRViCeS(a) Control Logic Pty Ltd (ABN 64 485 468 272) (Control Logic, Us, We, Our) conducts the business of supplying industrial, electrical and automation products, services and solutions.(b) Any equipment, goods or services supplied by Us (Goods and Services) to customers (Customer, You, Your) will be provided in accordance with these standard terms and conditions of sale (Terms and Conditions).
2. AGReeMenT(a) Publication of any materials by Us (including any catalogue, promotional material or marketing material) shall not constitute an offer for the supply of Goods and/or Services.(b) You may order Goods and/or Services from Us by any available means, including by submitting an order form, purchase order or other written request to Us (Order). Your Order will constitute an offer by You to Us for Us to supply the Goods and/or Services to You. We may accept such offer by written notice or confirmation to You. We may accept or reject any Orders from You in Our absolute discretion.(c) A binding agreement between Us and You (each a party and together the parties) for supply of Goods and/or Services on these Terms and Conditions (Agreement) will arise where (i) We have given written notice to You of acceptance of Your Order and agreed to supply the Goods and/or Services in accordance with the preceding paragraph; or (ii) You make a payment to Us for the Goods and/or Services (including the payment of any deposit) that is accepted by Us. Where We have accepted Your Order, the Order may not be withdrawn by You without Our prior written consent.(d) No other terms and conditions (including any terms and conditions which You provide to Us or seek to incorporate into this Agreement) will be binding upon Us or form part of this Agreement unless We have expressly agreed to them in writing. This shall apply irrespective of whether such terms and conditions have been communicated by You to Us in any purchase order or other correspondence between You and Us.
3. QUOTATiOnS(a) All quotations by Us for the supply of Goods and Services (Quotations) shall be made subject to these Terms and Conditions. We may withdraw Quotations at any time. Any clerical, calculation, or typographical error revealed in Our Quotation shall be subject to correction.(b) Unless specified otherwise any prices for Goods and/or Services: (i) will only be valid for a period of 30 days from the date of the Quotation; (ii) are given in Australian Dollars; (iii) are based upon costs and/or sale prices effective as at the date of the Quotation; (iv) are exclusive of GST, other taxes, charges and duties and any freight, insurance or delivery costs.
4. PRiCe And PAYMenT(a) You must pay to Us any price, charges or fees in respect of the Goods and Services as may be published by Us from time to time or as may be otherwise agreed between the parties in writing (Price).(b) Where We specify handling, packaging, crating, cartage, freight, insurance and/or delivery charges (Charges), such Charges are estimates only. Charges are payable to third parties and We reserve the right to vary Charges having regard to the amount actually due to third parties in connection with handing, cartage, freight, insurance or delivery.(c) Unless agreed otherwise, Goods will be made available for collection from Our premises which are located at 25 Lavarack Avenue, Eagle Farm QLD 4009 (Our Premises). Any Charges in connection with delivery to any other address will be payable by You.(d) We reserve the right to adjust Our prices from time to time to reflect fluctuations in currency exchange rates.(e) Prices are at all times subject to variation: (i) in accordance with increases and decreases in Our own internal costs of the Goods and/or Services or the prices of the manufacturers of the relevant Goods; and/or (ii) having regard to any cause beyond Our reasonable control. We reserve the right to change prices from time to time and update Charges to reflect the price of Goods and/or Services as applicable at the date of supply of the Goods and/or Services. In such circumstances, additional amounts may be payable by You. We will use reasonable endeavours to advise You of any variations in Price.(f) Unless We agree otherwise in writing, You must pay Us within 30 days from the date of Our invoice (Payment Terms). You must pay Us in accordance with any applicable Payment Terms. We may set off any amount owing to You against any amounts payable by You to Us under this Agreement.(g) We may charge interest on any amounts owing by You to Us which are not paid within the Payment Terms. Such amounts shall accrue interest at the current overdraft rate as published by Westpac Banking Corporation from time to time. Interest will arise from the date that payment was due and will be calculated monthly in arrears. We may capitalise interest. We reserve the right to charge a reasonable administration fee for late payment.(h) You shall not be entitled to withhold any amounts as a retention amount in respect of any Goods or Services.
5. iMPROVeMenTS And CHAnGeS in SPeCiFiCATiOn OF GOOdSIt is the policy of each manufacturer of Goods for continuous improvement of their Goods. We reserve the right to make changes to Goods in connection with any element (including materials, dimensions, specifications and design) and to obtain Goods from different sources in Our absolute discretion. We may make such changes where We consider (acting reasonably) that the alternative Goods are substantially similar to or an improvement to the original Goods. Such changes may be made without notice to You and will not affect the validity of any Agreement.
6. RiSK And TiTLe(a) Title in the Goods will remain with Us until payment of the Price for the relevant Goods has been received by Us in cleared funds.(b) Until legal and beneficial title in Goods passes to the You, You will hold the Goods as bailee for Us and must store the Goods separately and in a manner to enable them to be identified and cross-referenced to Our invoices. We reserve the right to enter Your premises or the premises of any associated company or agent where the Goods are located (Premises) without liability to trespass or any resulting damage and retake possession of the Goods.(c) Without limiting the generality of the preceding sub-clause, if You fail to pay any amounts owed to Us in accordance with the Payment Terms or are otherwise in default of these Terms and Conditions, We may or We may cause Our nominee to enter Your premises without notice to You and We or Our nominee may repossess the Goods.(d) For the purposes set out in paragraphs (b) and (c), You irrevocably grant Us and each of Our officers and agents (without the necessity of giving any notice) a licence to enter into and upon the Premises and to send for, remove and take possession of the Goods without being liable to You or any of Your officers, employees, agents of contractors (Associates) for so doing.(e) If the Goods are resold, or products manufactured using the Goods are sold, by You, You must hold such part of the proceeds of any such sale as represents the invoice price of the Goods sold or used in the manufacture of the Goods sold in a separate identifiable account as the beneficial property of Us and shall pay such amount to Us upon request. (f) Notwithstanding the provisions above, We shall be entitled to maintain an action against You for the Price and the risk of the Goods shall pass to the buyer at the earlier of the time at which the Goods: (i) are delivered to You; or (ii) are made available to You for collection.(g) Where We repossess Goods in accordance with this clause, We may elect to refund to You any part-payment that may have been made for the Goods and/or credit Your account for the value of the Goods less any charges for recovery of the Goods.
7. ACCePTAnCe OF GOOdSYou will be deemed to have accepted the Goods on the date that is 14 days after the date that the Goods were delivered to, or collected by, You.
8. YOUR OBLiGATiOnSWhen We or any of Our sub-contractors are required to perform any Services at Your premises, You must: (a) give Us access to Your premises to perform the Services; (b) ensure that there are adequate facilities made available for the performance of the Services; (c) comply with all applicable laws (including health and safety laws) and other applicable requirements in respect of such premises and their use; and (d) maintain adequate public liability insurance for those premises.
9. GSTWhere any supply made by Us is subject to GST, You will upon receipt of a valid tax invoice pay, in addition to any other consideration payable to Us, an amount equal to the GST on that supply.
10. AUSTRALiAn COnSUMeR LAWUnder the Australian Consumer Law (ACL), consumers have certain rights which cannot be excluded, including guarantees as to the acceptable quality and fitness for purpose of goods and services. Nothing in these Terms and Conditions shall be read or applied so as to exclude, restrict or modify or have the effect of excluding, restricting or modifying any condition, warranty, guarantee, right or remedy implied by law (including the ACL) and which by law cannot be excluded, restricted or modified and clause 11 shall be read subject to this clause.
11. WARRAnTieS(a) We warrant that all Goods ordered pursuant to these Terms and Conditions, will: (i) be of acceptable quality; (ii) be reasonably fit for their intended purpose; and (iii) be free from defect in material and workmanship (Warranties), in each case, for a period of 12 calendar months from the earlier of the date of delivery or collection (Warranty Period).(b) Written notice of any claim (a Warranty Claim) that Goods ordered pursuant to these Terms and Conditions do not comply with the Warranties must be given by You promptly (and in any event within 30 days of the date You first become aware or should have become aware that the Goods are properly the subject of a Warranty Claim).
783
Terms and Conditions of Sale
(c) The Warranties are in lieu of and exclude, to the maximum extent possible at law, all other guarantees and warranties, express or implied, arising by operation of law or otherwise. The Warranties do not apply to the extent that the non-conformance is due to: (i) normal wear and tear; (ii) the Goods, having been subject to neglect, accident, contamination, damage, misuse or improper installation, removal, maintenance or application by You; or (iii) any alteration, modification, repairs or attempts to correct a defect in the Goods which are made by persons that have not been authorised by Us to do so. (d) To the extent permitted by law and without limiting Your rights under the ACL, if We: (i) breach a Warranty; or (ii) fail to comply with a statutory guarantee which by law cannot be excluded, then to the extent the law permits Us to limit Our liability, Our liability for any breach of a Warranty shall be limited, at the election of Us, to providing You with any one or more of the following remedies: (iii) in relation to Goods: (A) replacement of (or payment for the replacement of) the Goods; (B) supply of (or payment for supply of) equivalent Goods; or (C) the repair or correction of (or payment for repair or correction of) the Goods; or (iv) in relation to Services: (A) supplying the Services again; or (B) payment of the cost of having the Services supplied again.
12. ReTURnS(a) We reserve the right to inspect any Goods which You consider are non-conforming. We will not accept liability for any costs of any inspection of, work on or other costs in connection with such Goods unless We have given Our prior written consent.(b) Unless We agree otherwise in writing: (i) the place of inspection for any Goods shall be at Our premises; and (ii) You will be responsible for the costs and expenses of returning any Goods to Us for the purposes of any inspection. If We agree to pay any costs for return of Goods, We reserve the right to select the method of transport used for any returns.(c) Goods will not be accepted for credit unless prior written agreement has been made by both parties. Acceptance by Us of Goods returned does not imply an agreement by Us to issue a credit note for the Goods. We will only issue a credit note for Goods once We have determined that the returned Goods are non-conforming.
13. deLAYS(a) Subject to the following sub-clause, We will use reasonable endeavours to deliver the Goods and/or supply the Services within agreed timeframes for delivery.(b) We will not be liable for any delay or failure to perform Our obligations if such failure or delay has been caused by You or is due to an act, omission or circumstance over which We could not reasonably have exercised control (Force Majeure Event). We will notify You as soon as practicable and within 5 days after that We become aware of the Force Majeure Event. The performance of Our obligations under this Agreement will be suspended for the period of the delay due to Force Majeure Event. If a delay due to Force Majeure Event exceeds 30 days, We may terminate this Agreement immediately on giving written notice to You. If We give such notice to You: (a) We will refund amounts previously paid by You under this Agreement for which no Goods or Services have been provided; and (b) You must pay Us for Goods supplied and a reasonable sum in relation to Services rendered or costs and expenses incurred by Us prior to such termination.(c) Under no circumstances will We be liable to pay You liquidated damages for any reason whatsoever.
14. deFAULTWe may refuse to deliver Goods or Services to You and/or otherwise withhold supply of Goods and/or Services to You and/or may terminate the Agreement if You: (a) are in default of these Terms and Conditions (including any payment obligations); (b) fail to meet Our credit requirements or are in breach of any terms and conditions of any credit agreement You have entered into with Us; or (c) enter into liquidation or administration, are adjudged bankrupt, become insolvent or are otherwise unable to pay Your debts as and when they fall due.
15. LiABiLiTY(a) You indemnify and hold harmless Control Logic against any liabilities, claims, actions, suits, proceedings, losses, damages, costs, fees and expenses (Claims) in connection with Our performance or otherwise of any obligations under these Terms and Conditions to the extent that such Claims have been caused by or contributed to by You or any of Your officers, employees or agents.(b) We shall not be liable to You, whether for loss of profits, or liability for any consequential or indirect loss of any nature whatsoever, including without limitation liabilities, losses, damage, damages, penalties, fines, taxes, judgments, costs and legal and other expenses including but not limited to loss of use, revenue or any loss of business, loss of opportunity, loss of production, contract or goodwill.
16. diSPUTe ReSOLUTiOnEither party may require any dispute between the parties arising out of or in connection with this Agreement (Dispute), which has not been resolved within 14 days, to be referred to the senior management of the respective parties. If within 28 days of such referral, a resolution of the Dispute has not been achieved then
either party may commence court proceedings. Notwithstanding the existence of a Dispute, or the undertaking of the dispute resolution steps set out in this clause, each party must continue to perform its obligations under this Agreement. The provisions of this clause shall not limit or affect the rights of either party to apply to the court at any time for any interim or preliminary relief in respect of the Dispute.
17. inTeLLeCTUAL PROPeRTY RiGHTS And MATeRiALS(a) Any information, documents or other materials We provide to You in connection with the Services (Our Materials) and any intellectual property rights (including copyright) comprised in Our Materials will remain the property of Us and/or Our third party licensors. You must not modify, copy, reproduce, re-publish or distribute Our Materials in any way except with Our express prior written consent. Our Materials contain information of a general nature only. Any information or data contained in Our Materials is not intended to replace or serve as a substitute for any professional consultation or service and must not be relied upon as such.(b) You warrant to Us that You are authorised to provide any information, designs, documents or other materials (Your Materials) that You provide to Us. You warrant to Us that You are the owner or licensee of any intellectual property rights comprised within Your Materials and that You are authorised to provide such materials to Us. You grant Us an irrevocable, perpetual, worldwide, royalty-free licence to use Your Materials for the purpose of delivering Goods and/or Services to You. You indemnify and hold Us harmless against all Claims arising in connection with Our use of Your Materials.
18. PRiVACYWe may collect information about You and/or Your Associates in connection with the performance of this Agreement and the Services. We may not be able to perform the Services if all the information requested by Us is not provided. Information collected and held about You and Your Associates may be used by Us in connection with the performance of Our obligations under this Agreement (including provision of the Services). We may disclose such information to Our related bodies corporate and contractors for the purposes of performing the Services. Under the Privacy Act 1988 (Cth), individuals have rights of access to, and correction of, their personal information. We will comply with the Privacy Act 1988 (Cth) and any applicable regulations and codes in connection with the collection and use such information.
19. PeRSOnAL PROPeRTY SeCURiTieS ACTYou acknowledge that these Terms and Conditions constitute a security agreement for the purposes of section 20 of the Personal Property Securities Act 2009 (Cth) (PPSA) and that a purchase money security interest exists in all Goods (and their proceeds) supplied by Us to You pursuant to these Terms and Conditions. To the extent permitted by law, You waive any rights to receive any notice or statement under Part 4 of the PPSA.
20. GeneRAL PROViSiOnS(a) The Terms and Conditions (as may be amended from time to time in writing): (i) are governed by the law in force in Queensland and each party irrevocably submits to the non-exclusive jurisdiction of the courts of Queensland; (ii) together with any applicable credit terms and other terms to which We have expressly agreed constitute the entire agreement between the parties in relation to the Goods and Services and supersede all other terms and conditions issued by You otherwise than in accordance with this Agreement; and (iii) do not create a relationship of principal and agent, joint venture, partnership or fiduciary relationship between the parties.(b) Other than as permitted by these Terms and Conditions, any variation of this Agreement must be in writing signed by both parties.(c) You must not assign, transfer or novate this Agreement or any rights or obligations under this Agreement, without the prior written consent of Us. You authorise Us to sub-contract the provision of any of the Services as We may require in Our absolute discretion from time to time and at any time.(d) Neither party may rely on the words or conduct of the other party as a waiver of any right unless that waiver is in writing and signed by the party granting the waiver.(e) To the extent that any clause or part of any clause is in any way unenforceable, invalid or illegal, it is to be read down so as to be enforceable, valid and legal. In the event this is not possible, the clause (or where possible, the offending part) is to be severed from this Agreement without affecting the enforceability, validity or legality of the remaining clauses (or parts of those clauses as the case may be) which will continue in full force and effect.(f) In this document: (i) a reference to a clause is a reference to a clause of this document; (ii) clause headings are inserted for convenience only and do not form part of this document; (iii) including and includes are not words of limitation; and (iv) the singular includes the plural and vice-versa.
PHONE 1800 557 705 | FAX 1800 237 743 | www.control-logic.com.au | [email protected]
Disclaimer
Terms of Supply and disclaimer:
This publication has been prepared by Control Logic Pty Ltd (ABN 64 485 468 272) (Control Logic, Us, We, Our).Unless stated otherwise:
• the product details and specifications stated in this publication are correct as at July 2013;• products set out in this publication are only available for sale within Australia;
Products offered for sale in this publication are subject to our standard Terms and Conditions of Supply, which are applicable at the date the order is placed. Our standard Conditions of Supply may be viewed on our website at:
http://www.control-logic.com.au/about-us/terms-and-conditions
Alternatively, you may request a copy of Our standard Conditions of Supply from Our office.The products described in this publication should only be installed and/or used in accordance with any accompanying instruction sheets, manuals and/or specifications.
All product specifications are subject to change without notice and should be confirmed at the time of placing your order.
Whilst every effort has been taken to ensure that this publication is accurate, to the maximum extent permitted by law, no representation or warranty, express or implied, is or will be made in relation to, nor will any responsibility or liability (whether for negligence, under statute or otherwise) be accepted by Us or by any of Our respective officers, directors, shareholders, employees or agents, contractors as to or in relation to the accuracy or completeness of the information, details, specifications, statements or matters (express or implied) arising out of, contained in or derived from this publication or any omission from this publication. Information in this publication may have been provided to Control Logic by third parties. We do not adopt or endorse any information which has been obtained from third parties and to the maximum extent permitted by law, We make no warranty as to the validity or accuracy of such information.
We reserve the right at any time and without notice to change any products, product details and product specifications.This publication, any part of this publication and any reference to this publication must not be included in any published materials without Our prior written approval.
July 2013
© Control Logic Pty Ltd 2013
785industrial. electrical. Automation. P 1800 557 705 | www.control-logic.com.au | [email protected]
If you‘ve got the best equipment, you feel good about taking the plunge. But you‘re only truly safe when you have an experienced partner by your side. As far as machine safety is concerned, people all over Australia trust in expertise from Control Logic.
Safety is a matter of trust.
Queensland ::Brisbane (Head Office)25 Lavarack Ave Eagle FarmPO Box 1456 Eagle FarmQLD Australia 4009P : 07 3623 1212F : 07 3623 1211
South Australia ::Adelaide2/474 Port Rd Hindmarsh SA 5007P : 08 8340 0833F : 08 8241 5536
Western Australia ::Perth4/83 Kent Way Malaga WA 6090P : 08 9249 5158F : 08 9209 2151
New South Wales ::Sydney4/1B Kleins RdNorthmead NSW 2152P : 02 9890 1120F : 02 9890 2204
Newcastle 4/155 Lambton RdBroadmeadow NSW 2292P : 02 4956 1761F : 1800 237 743
Victoria ::MelbourneUnit 5/8 Samantha CourtKnoxfield, VIC 3180P : 03 9763 1666F : 03 9753 2702
CUSTOMER SERVICEPH: 1800 557 705FAX: 1800 237 743Email: [email protected]: www.control-logic.com.au
Control Logic Pty LtdABN No. 64 485 468 272 | © Copyright Control Logic
Visit the Control Logic website by simply scaning the QR code to the left using your smartphone’s camera.
You can download a free QR scanner application from your phone’s app store.