Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco...

102

Transcript of Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco...

Page 1: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical
Page 2: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking

Mark Allen – Technical Leader

BRKARC-1222

Page 3: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

• Data Center Trends

• Fibre Channel Storage Networking

• Converged Storage Networking

• Storage Deployments

• Storage Networking Management

• Wrap Up

Agenda

Page 4: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Purpose of Storage

Everything we do in storage (including storage networking) is based around completing that job safely, securely, reliably, and without error

One Main

Job: “Give me back the correct bit

I asked you to hold on for me.”

4© 2016 Cisco and/or its affiliates. All rights reserved. Cisco PublicBRKARC-1222 4

Page 5: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Data Center Trends

Page 6: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Sources: Cisco Visual Networking Index (VNI), Cisco Cloud Index, IDC, Gartner, IDC WW Integrated Systems Forecast 2014-2018 (Nov ‘14)IDC WW Hyperconverged Systems 2015-2019 Forecast (April ’15)

EFFECT ON STORAGE INFRASTRUCTURE

6%

14%

58%

Integrated PlatformCAGR by 2015-18

Integrated InfrastructureCAGR by 2015-18

HyperconvergedCAGR by 2015-18

Infrastructure Agility Needed to Enable Greater Speed of Business

Internet of Things40% CAGR by 2017

Cloud69% CAGR by 2017

Analytics69% CAGR by 2014-19

INDUSTRY DYNAMICS

Growth in Information Created by 2020

Higher Demand

on Multiprotocol Storage

STORAGE GROWTH

10Xs

IT Environments Experiencing Accelerating Transitions

DATA CENTER TRENDS

Server Virtualization85% by 2018

Software Defined

Infrastructure65% Growth by 2017

Increased Flash Usage7x Growth SSD by 2018

BRKARC-1222 6

Page 7: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Cisco’s Family of Storage Networking Solutions

Nexus UCS

LAN/SAN SAN COMPUTE

MDS

BRKARC-1222 7

Page 8: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Cisco Multi-Protocol PortfolioSAN, LAN & Compute

LAN/SAN

Cisco Nexus 9000

Cisco Nexus 7000

Cisco Nexus 5600

Cisco Nexus 5500

CiscoNexus 3000

CiscoNexus 2000

Nexus 5672UP-16G

SAN COMPUTE

Nexus 2348UPQ

CiscoMDS 9706/9710

48x16G Line-Rate FC

CiscoMDS 9148S

48x10G Line-Rate FCoE

CiscoMDS 9396S

CiscoMDS 9718

24 x 40GLine-Rate FCoE

CiscoMDS 9250i

Cisco UCS C-SeriesRack Servers

Cisco UCS B-SeriesBlade Servers

Cisco UCS 6200 Series FI

Cisco UCS 6300 Series FI

Common OS, Common Management

BRKARC-1222 8

Page 9: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Fibre Channel Storage Networking

Page 10: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Deploy Small, Medium, Large FC SANs with Cisco MDS 9000 Family

12-48

48-96

48-192

48-384

20-40

Cisco 16G Multi-layer

Director SeriesCisco 16G Multilayer

Fabric Switch Series

Cisco Multiservice

Fabric Switch

Fib

re C

ha

nn

el S

ca

le

48-768

Cisco MDS 9000 16G Fibre Channel Family

MDS 9148S MDS 9396S MDS 9250i MDS 9706 MDS 9710 MDS 9718

BRKARC-1222 10

Page 11: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

MDS 9700 Series Multi Layer Directors

Page 12: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Cisco MDS 9710 Director

Cisco MDS 9706 Director

Cisco 48x16G

Line-rate FC Module

Cisco 48x10GE

Line-rate FCoE Module

Cisco MDS 9706, 9710 and 9718 Product Portfolio

Cisco MDS 9718 Director

Cisco 24x40GE

Line-rate FCoE Module

16G FC, 10/40GE FCoE Today32G FC Ready

BRKARC-1222 12

Page 13: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

1.5-Tbps/Slot384 Line-Rate 16G FC Ports

STORAGE DIRECTORN+1 Fabric

INDUSTRY’S MOST RELIABLE

WITH MULTI-PROTOCOLCONNECTIVITY

UNMATCHEDFLEXIBILITY

INDUSTRY’S HIGHESTPERFORMANCE AND

CAPACITY

14 RU

Launched May 2013

Cisco MDS 9710 Multilayer Director

• Up to 8 Line Cards

• Up to 6 Fabric Modules

• Dual Supervisors

Investment Protection for the Next Decade

BRKARC-1222 13

Page 14: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

3x THE PERFORMANCE

OF ANY COMPACT

DIRECTOR

INDUSTRY’S MOST

RELIABLE COMPACT

DIRECTOR

• AND 15X the performance of current MDS 9506 director

• Grow without forklift –investment protection for future

1.5 Tbps/slot Switching Capacity

• Preserve IT operations and Knowledge – ease of migration with NX-OS and DCNM

• Eliminate loss of bandwidth

N+1 Fabric Redundancy

• Eliminate Downtime

In-Service Software Upgrade

Dual, Redundant Supervisors

Redundant power supplies/fans

• Maintain Performance

Reduced Failure Domains

Launched September 2014

9RU

Cisco MDS 9706 Multilayer DirectorExtending MDS 9710 Director Qualities to a Smaller Form Factor

Front-Back Airflow

Scale up to 192 Line Rate Ports –

16G FC or 10G FCoE

BRKARC-1222 14

Page 15: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Designed for Consolidation and High-Scale SAN Fabrics

Same Features and Functionality as MDS 9706 and 9710

• High Availability – Redundant Supervisors, Power Supplies and Fabric Modules

• Performance – 1.5 Tbps bandwidth per slot = 768 x 32Gbs line rate ports

• Investment Protection – Same NX-OS, Line Cards, Power Supplies as other MDS 9700 directors

Plus

• New Supervisor 1E (Enhanced) with 2x Compute and 4x Memory of Supervisor 1

• Fully populated Fabric Modules – 32Gbps ready at FCS

Cisco MDS 9718 Multilayer DirectorIndustry’s First Ultra-High Density Director

BRKARC-1222 15

Page 16: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Comparison: 9706, 9710 and 9718

Hardware Feature MDS 9706 MDS 9710 MDS 9718

Line Card slots 4 8 16

RU 9RU 14RU 26RU

Fabric Module slots

(default / available)3 / 6 3 / 6 6 / 6

Sup Slots 2 2 2

Fabric Module location Back Back Back

Airflow Front to Back Front to Back Front to Back

Power Supply slots 4 8 16

BRKARC-1222 16

Page 17: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

FC, FCoE Modules

Cisco MDS 9700 - Designed for Scale1

2

3

4

5

6

Host Ports

Number of Fabric

CardsFC Bandwidth per Slot FCoE Bandwidth per Slot

1 256 Gbps 220 Gbps

2 512 Gbps 440 Gbps

3 768 Gbps 660 Gbps

4 1024 Gbps 880 Gbps

5 1280 Gbps 1100 Gbps

6 1536 Gbps 1320 Gbps

BRKARC-1222 17

Page 18: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

The Benefits Of Multiple Fabrics

Two key design benefits:

1. Operational Redundancy: Uptime at full performance

2. Investment Protection: Scale up with addition rather than replacement: (32G FC)

Number Of

Fabric Cards

Front-Panel FC

Bandwidth / Slot

1 256 Gbps

2 512 Gbps

3 768 Gbps

4 1024 Gbps

5 1280 Gbps

6 1536 Gbps

0

256

512

768

1024

1280

1536

1 2 3 4 5 6

Band

width-Gb

ps

NumberOfFabricCards

PossibleFront-PanelBandwidthPerSlot

Future

Proof

Growth

N+1 redundancy at 8G FC

N+1 redundancy at 16G FC

Cisco MDS 9700

BRKARC-1222 18

Page 19: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

• New half-width form factor

• 10/100/1000 Management port, RJ45 Console port, 2 x USB 2.0 ports

• More powerful Supervisors allow greater scalability

MDS 9500

Sup 2A

MDS 9706/9710

Sup 1

MDS 9718

Sup 1E

Memory 2G 8G 32G

# of Cores 1 4 8

Clock Speed 1.4 Ghz 2.1 GHz 2.1 GHz

Instruction 32-bit 64-bit 64-bit

MDS 9710 Supervisor Modules

BRKARC-1222 19

Page 20: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

MDS 9700 Power Supplies

Grid A Grid B

Power Distribution Unit-B

Power Distribution Unit-A

• New form factor 3000W power supply module

• Autosensing voltage detection

• 80Plus Platinum Certified (>94% efficiency)

• Both AC and DC power supplies available

• Can mix AC and DC power supplies in same chassis

• Grid Redundancy for all chassis

• Four Power Supplies – MDS 9706

• Six to Eight Power Supplies – MDS 9710

• Twelve to Sixteen Power Supplies – MDS 9718

• N+N:N+N Power Redundancy optional for MDS 9710 and 9718 chassis

BRKARC-1222 20

Page 21: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

48-port 16-Gbps Line Card

Performance 48 x 16 Gbps ports, 768 Gbps (3 Fabric Modules for line rate speed)

Port Speeds 2, 4, 8, 10 and 16 Gbps Fibre Channel

Optics (sfp+) 2/4/8G FC, 4/8/16G FC, 10G FC, 10GE (FC with 10GE clock)

Port Types F, FL, TF, E, TE, SD, ST

Port Groups Twelve 4-port port-groups

Intelligent Capabilities VSAN, IVR, FC Redirect

Buffer-to-buffer credits Up to 500 per port, 4095 with Enterprise License (510km @ 16G)

MDS 9700 48-Port 16G Fibre Channel Line Card

BRKARC-1222 21

Page 22: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

MDS 9700 48-port 10GE FCoE Line Card

48-Port 10GE FCoE Line Card

Performance 48 x 10 Gbps ports, 480 Gbps (3 Fabric Modules for line rate speed)

Port Speed 10 Gbps Ethernet

Port Types VF, VE, VTE

Port Groups Twelve 4-port port-groups

Intelligent Capabilities VSAN, IVR

BRKARC-1222 22

Page 23: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

MDS 9700 24-port 40GE FCoE Line Card

24-Port 40GE FCoE Line Card

Performance 24 x 40 Gbps ports, 960 Gbps (5 Fabric Modules for line rate speed)

Port Speed 40 Gbps Ethernet

Port Types VF, VE, VTE

Port Groups Four 6-port port-groups

Intelligent Capabilities VSAN, IVR

BRKARC-1222 23

Page 24: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

MDS 9000 Series Fabric Switches

Page 25: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

High-Performance, Easy to Deploy,Enterprise-class Fabric Switch

Cisco MDS 9148S Fabric Switch

VERSATILE EASY TO USE ENTERPRISE-CLASS

• Line-rate 16/8/4/2G FC Ports

• Industry-leading port range

12-port base

Scale up with 12-port licenses

Full 48-port option available

• Automated Provisioning

• Quick Configuration Wizard

• Same OS and Management across Industry’s broadest SAN Portfolio

• Non-disruptive software upgrades

• Up to 32 Virtual SANs (VSANs)

• Inter-VSAN Routing (IVR), QOS, PortChannels, N-Port ID Virtualization (NPIV), N-Port Virtualization (NPV), Comprehensive Security

• Hardware-based slow-drain detection and recovery

Back

Dual Power Supplies and Fans for Enterprise-Class Availability

Front

48 x 16G FC Line Rate Performance

Expand from 12- to 48-ports in 12-port increments

1 RU

BRKARC-1222 25

Page 26: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

MDS 9396S Fabric Switch2RU 96-port 16G Line-Rate Switch

Front View

Blend of Fabric Switch and Director CapabilitiesDeploy as a Stand-Alone switch or as an Edge Switch for an Edge-Core Network

Rear View

Hardware Platform• 2RU 96-port 16G FC fixed fabric switch• 2/4/8 and 16-Gbps Line-rate Fibre Channel speeds• Redundant power supplies and fans, with Port Side Exhaust or Port Side

Intake air flow

Enterprise Class • Up to 4095 B2B credits / port• FC TrustSec Encryption• Forward Error Correction

Fabric Switch-like Capabilities• On demand port licensing (48-port base with 12-port incremental licenses)• NPV Mode• Power-On-Auto-Provisioning (POAP), Quick Configuration Wizard

BRKARC-1222 26

Page 27: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

MDS 9396S: Performance of a Director

• Same Port ASICs

• Same Crossbar ASIC

Based on the architecture of 48-port 16G FC line card of MDS9700 director

BRKARC-1222 27

Page 28: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Entry-Level SANs Mid-Tier Standalone SANs Mid-Tier Private Cloud SANs

MDS 9148S

• Start with 12-Port 16G FC base• Grow in 12-port increments

12 24 36 48 ports• Two base configurations

12, 48 ports

• Start with 48-Port 16G FC base• Grow in 12-port increments

48 60 72 84 96 ports• Two base configurations

48, 96 ports

MDS 9396S

MDS 9396S deployed

as a Middle-of-Row (MoR)

Switch

. . . . . . .

MDS 9700

• Deploy MDS 9396S across two racks as a MoR switch – connect to end-of-row MDS 9700 Director

• Deploy in N-Port Virtualization (NPV) mode to reduce number of managed switches

Use MDS 16G FC Fabric Switches to deploy state-of-the-art SAN solutions for small to mid-Tier SANs

Versatile, High-Performance FC Solutions

BRKARC-1222 28

Page 29: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

MDS 9000 Series Multiservice Fabric Switch

Page 30: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

FCoE1 2 3 4 5 6 7 8

MDS 9250i Multiservice Fabric Switch

FeaturesLine Rate Performance for:

• 16G FC, 10GE FCoE, 10GE FCIP, FICON, iSCSI

Rich set of Storage Services for FC and FCoE SANs:

• FCIP, IO Accelerator (IOA), Data Mobility Migration (DMM),

• Integrated Management via Data Center Network Manager (DCNM)

Next-Gen Storage Services Platform for Unified Fabric

40 Ports 16G FC 8 Ports 10GE FCoE

2 Ports 10GE FCIP/iSCSI 1+1 Redundant Fans2+1 Redundant Power Supplies

BenefitsSingle Platform for deploying Storage Services across FC and FCoE Storage Area Networks (SANs):

• High-Bandwidth SAN Extension across MAN/WAN• Migrate Data between FC and FCoE arrays

BRKARC-1222 30

Page 31: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

MDS 9250i Multiservice Fabric SwitchBUSINESS CONTINUITY/DISASTER RECOVERY

Production

DC

Disaster Recovery

DC

IP WAN

FC FCoE

SAN

FC FCoE

SAN

DATA MIGRATION

FC FCoE

SAN SAN

FC SAN GATEWAY

FC

FCoE

Converged

Fabric

SAN

FC SAN SWITCH

FC

FC

SAN

Migrate data between

heterogenous storage

One SAN Appliance, Multiple Use-CasesBRKARC-1222 31

Page 32: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

MDS Architecture

Page 33: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Crossbar Switch with Central Arbitration

Ingress

Egress

Crossbar

Control and

Scheduling

Cisco MDS Architecture Overview

MDS Family - Arbitrated Crossbar Architecture

• Crossbar maybe external (MDS 9700 Directors, MDS 9396S) or integrated into ASIC (MDS 9250i and MDS 9148S)

• Crossbar establishes a temporary connection between input and output port for duration of the frame exchange

• Frames are not transmitted unless there is an available path

• Scheduler uses arbiter grants to provide traffic fairness and QoS

• Virtual Output Queues used to eliminate HOL blocking

BRKARC-1222 33

Page 34: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Cisco MDS Frame Flow

• Frames always follow same logic – ingress to egress (consistent switching latency)

• Newer generation line cards use fewer components compared to first generation line cards, however, the frame forwarding logic is the same

SupCentral

Arbiter

Egress Access Control and QoS

Forwarding and Load balancing

Inter VSAN Routing

SupCentral

Arbiter

MAC

Port Type / Modes:

• F_Port

• Loop port (FL_Port)

• ISL (E_Port)

• EISL (TE_Port)

• SPAN Port (SD_Port)

PHY / MAC Forwarding

Queuing

PHY

Optical to Electrical

interface:

• SFP+ (2/4/8/10/16 Gbps)

Error Checking

Timestamp

VSAN Header

Linecard

Access Control

Forwarding and Load balancing

Inter VSAN Routing

Interface Statistics

Buffering and Virtual Output Queues

QoS

Arbitration Requests

Redundant Arbiters

Transmit, loopback or Expire frame

Remove VSAN header (end device) or prepend

EISL header (EISL to Cisco switch) Redundant crossbar fabrics

BRKARC-1222 34

Page 35: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows

• PHY

• Optical to electrical conversion

• 2/4/8/10/16-Gbps SFP

• MAC

• Decipher FC frames from incoming bit stream using SOF/EOF primitives

• Issue R_RDYs (return buffer credits)

• Check incoming frame for errors (CRC check)

• Prepend switch-internal header• Ingress port, ingress VSAN, QoS markings, frame arrival time, etc

1. Frame arrives on ingress PHY/MAC

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

BRKARC-1222 35

Page 36: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows

• H/W-based frame forwarding distributed on each line card:

• VSAN-aware (forwarding based on VSAN & D_ID – “virutal fabric aware”)

• Ingress ACLs (Hard zoning)

• Load-balancing (FSPF and/or Port Channels)

• Inter VSAN Routing including FC-NAT (integrated – no loss of performance)

2. Ingress Forwarding logic

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

Per-VSAN

Ingress ACL

Lookup

PermitPer-VSAN

Forwarding Table

Lookup

Multiple

Destinations?

SRC/DST

require

Inter VSAN

Routing?

Incoming

Frame

Load-balancing

Update Flow,

Interface & VSAN

Statistics

Statistics Lookup

YesYes

FC-NAT

to Queuing

Drop Frame

BRKARC-1222 36

Page 37: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows3. Ingress Queuing / Request-to-send logic

Ingress FC Port

Transmit

Queue

PQ

Classify

DWRR 2

DWRR 3

DWRR 4

Choose Crossbar

Channel

Signal free

Destination

Queue slot

Wait

For

Grant

Incoming

Frame

Request Grant from

Arbiter

Queue Frame on

ingress-port VoQ

Determine Destination

Virtual Output QueueTransmit Frame

to Crossbar

Switch Fabric

Virtual Output queuing

Interface to centralized arbitration

Buffering/Queuing (in case of congestion)

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

BRKARC-1222 37

Page 38: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows4a. Centralized Arbiters

Responsible for scheduling frames from ingress to egress

Capable of scheduling more than a billion frames/sec

Ensures fairness when there is congestion on output ports:

Congestion does not result in blocking because of VoQs

VOQ model

Frame to port 5Frame to port 5 Frame to port 6

Frame to port 4Frame to port 4

Frame to port 6

Frame to port 6Frame to port 4

Input queue at port 1

Top of virtual output queue

Input queue at port 1 Input queue at port 1

Top of virtual output queue

Top of virtual output queue

Switch without VOQ

Frame to port 5Frame to port 5Frame to Port 6Frame to port 4Frame to port 4Frame to port 6Frame to port 6Frame to port 4

Input queue at port 1

Top of queue

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

BRKARC-1222 38

Page 39: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows

• Low-latency, high-throughput non-blocking, non-oversubscribed crossbar switch fabric

• Guaranteed bandwidth for frames being transmitted

• No over-subscription in MDS 16G platforms

4b. Crossbar switch fabrics

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

BRKARC-1222 39

Page 40: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows

• Check frame integrity (again)

• Egress ACLs

• Egress QoS

5. Egress forwarding logic

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

Incoming

frame

from Crossbar

Switch Fabric

IVR

FC-NAT RewritePer-Port

Class-of-Service

Output Queue

Per-VSAN Egress ACL

Lookup

Permit

DenyDrop Frame

Valid

BadDrop Frame

Check Frame for

Errors

BRKARC-1222 40

Page 41: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Frame Flows

• Remove internal switch header

• If output port is a Trunked E_Port (VSAN Trunking), prepend EISL header

• Check frame timestamp (drop expired frames)

• Transmit frame onto wire with appropriate encoding & primitives

6. Egress MAC/PHY logic

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

Fabric

Crossbar

Switch

Fabric

SupCentral

Arbiter

SupCentral

Arbiter

PHY / MAC Forwarding

Queuing

BRKARC-1222 41

Page 42: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

VSANs – The Technical Details

• Several fields are added to the VSAN header that provide a variety of functions

• Each frame on a VSAN trunk carries up to an extra 8 bytes of header which includes:• User priority – 3 bits – used for QoS functionality to designate

priority of frame

• VSAN ID – 12 bits – used to mark the frame as part of a particular VSAN – supports up to 4096 VSANs

• MPLS flag – 1 bit – used to designate whether this frame is subject to Multi-Protocol Label Switching processing – future use

• Time-to-live (TTL) – 8 bits – used to help avoid routing loops

• Other misc. fields including version, frame type, and other reserved fields

EISL Header – What’s inside?SOF

EISL Header

4B

8B

FC Header24B

Payload≤2112B

CRC

EOF

4B

4B

BRKARC-1222 42

Page 43: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Designed For Fabric Resiliency

• Lossy Media such as loose SFPs, dirty cables can result in packets getting corrupted

• CRC Checking drops corrupted frames from end devices or internally corrupted frames

• FEC corrects frames corrupted in-flight to preserve frames

CRC Detection and 16 Gbps FC Forward Error Correction (FEC)

Ingress

CRC

checking

Internal

CRC

checking

Forward

Error

Correction

Drop

frame

Drop

frame

BRKARC-1222 43

Page 44: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Converged Storage Networking

Page 45: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Industry’s Broadest Converged Ethernet Portfolio

Max FCoE / IP

Ports/Chassis

Nexus 7700/7000 Nexus 5600 Nexus 2300 Nexus 9000

10GE1536 (IP),

768 (FCoE)384 48 2048

40GE 384 96 6 512

Cisco NEXUS

Use 10/40G Ethernet to Converge IP and Fibre Channel Storage Traffic

Application Centric

Infrastructure (ACI)

MDS 9000

768 (FCoE only)

2 (IP)

384 Ports

Cisco MDS

UCS FI

6200/6300

96

32

Cisco UCS

BRKARC-1222 45

Page 46: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

6x 40G QSFP+ Ports

Flexibility to use 4x10G or

40G

24 Fixed 1/10G SFP+

Ports24 Unified Ports provide

2/4/8/16G FC

or 10G Ethernet/FCoE

Cisco Nexus 5672UP-16G

• Flexible – Traditional Ethernet plus Storage: File, iSCSI, FCoE and FC

• Reduced cost – Deploy once, implement solutions as needed

All Features of Nexus 5600 and More

Enhanced 5672UP for SAN

BRKARC-1222 46

Page 47: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Unified Ports provide 2/4/8/16G

FC or 10G Ethernet/FCoE

Up to 24 x 16G FC ports

Up to 48 x 2/4/8G FC ports

6 x 40G QSFP+ Ports

Flexibility to use

4 x 10G or 40G

• Flexible – Deploy ports as required, LAN or SAN

• Reduced cost – Lower cost than Ethernet switch

• Reduced management –Configuration and OS done on parent switch

First FEX Solution Designed for All Storage Connectivity

Cisco Nexus 2348UPQ Fabric Extender

BRKARC-1222 47

Page 48: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

FI 633232 x 40GbE QSFP+ ports

FI 6332-16UP24 x 40GbE QSFP+ and 16 x UP ports (1/10GbE or 4/8/16G FC)

IOM 23048 x 40GbE server links and 4 x 40GbE QSFP+ uplinks

Next Generation UCS Fabric Interconnect UCS FI 6332, UCS FI6332-16UP, IOM 2304

Enabling High Performance, Low-Latency and Lossless Fabric

• High-density 40GbE

ports: enables 40G

end-to-end Fabric

• 2.6X increase in

throughput

• 3X lower latency

BRKARC-1222 48

Page 49: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Storage Deployments

Page 50: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

CORE-EDGE DESIGN

6 x 384 port directors

256 ISL ports

1792 ports deployed

704 Server ports

per fabric

64 Target ports

per fabric

COLLAPSED CORE DESIGN

2 x 768 port directors

0 ISL ports

1536 ports deployed

704 Server ports

per fabric

64 Target ports

per fabricREDUCED

MANAGEMENT

Fewer switches to manage

No ISLs to manage

REDUCED

POWER

Fewer switches

Fewer ports deployed (no

ports used by ISLs)

REDUCED

CABLING Elimination of ISL cables

BENEFITS:

MDS 9718 Use Case:Switch Consolidation

BRKARC-1222 50

Page 51: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

EDGE-CORE-EDGE DESIGN

26 x 384 port directors

3072 ISL ports

9216 ports deployed

Core at maximum capacity

384 Target ports

per fabric

2688 host ports per

fabric

….8…. ….8….

CORE-EDGE DESIGN

4 x 768 port directors, 16 x 384 port directors

1536 ISL ports

7680 ports deployed

Core can continue to grow storage and edges

384 Target ports

per fabric

2688 host ports per

fabric

….8…. ….8….

REDUCED

OPEX

Fewer switches to manage

Fewer ISLs to manage

REDUCED

CAPEX

Fewer switches deployed

Fewer ports deployed

(fewer ISLs)

REDUCED

CABLING

Elimination of ISL

ports/cables

BENEFITS:

MDS 9718 USE CASE:SCALED GROWTH

CORE-EDGE DESIGN

5151

Page 52: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

CISCO 40G QSFP BIDI TRANSCEIVERSUTILIZING EXISTING DUPLEX FIBER

LC Fiber Cable

Duplex 20 Gbps (Receive and

Transmit on Two Different Wavelengths)

OM3 MMF: 100m

OM4 MMF: 150m

LC Cable with 40G QSFP-BiDi

Duple

x L

C

Duple

x L

C

OM3 MMF: 100m

OM4 MMF: 150m

MPO-12 Fiber Cable

8 Fiber Strands Carry 10 Gbps Each;

4 Fiber Strands Unused

MPO-12 Cable with 40G QSFP-

SR4

12-F

iber

MP

O

12-F

iber M

PO

LC Fiber Cable

Each Fiber Strand Carries

16G/10 Gbps

OM3 MMF: 300m (10G), 100m (16G)

OM4 MMF: 400m (10G), 125m (16G)

LC Cable with SFP+

LC

LC

No Need to Upgrade the Fiber Plant

52BRKARC-1222 52

Page 53: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

40GE FCoE ISLs

6 x 384 port directors

96 ISL ports

1632 ports deployed

704 Server ports

per fabric

64 Target ports

per fabric

96

ISL Ports

REDUCED

MANAGEMENT Fewer ISLs to manage

REUSE

CABLING

BiDi Optics allow use of

existing LC cabling

BENEFITS:

16G FC ISLs

6 x 384 port directors

256 ISL ports

1792 ports deployed

704 Server ports

per fabric

64 Target ports

per fabric

256

ISL Ports

40GE ISL USE CASE:ISL CONSOLIDATION

53BRKARC-1222 53

Page 54: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

NEXUS Fixed / Modular

40GE FCoE

10GE FCoE

NEXUS with FEX

40GE FCoE

10GE FCoE

UCS with 6333 Fabric Interconnect

40GE FCoE

40GE ISL USE CASES:CONVERGED NETWORKS TO FIBRE CHANNEL SAN

54BRKARC-1222 54

Page 55: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Ethernet and FC Connectivity

5672UP-16

16G FC

8/16G FC

Ethernet LAN

Converged Access to FC and IP Storage

10GE FCoE

16G FC 40GE

Ethernet LAN

5672UP-16

FC SAN

IP Storage

10GE 5672UP-16

Nexus Spine

40GE

Cisco Nexus 5672UP-16G Use Cases

55BRKARC-1222 55

Page 56: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

UP FEX RACK ARCHITECTURE

2 x LAN/SAN

2348UPQ FEX

To LAN/SAN Parent Switch

Rack Mount

Servers

TRADITIONAL RACK

ARCHITECTURE

2 x TOR LAN

Switches

To LAN

Rack Mount

Servers

To SAN

2 x TOR SAN

Switches

CISCO NEXUS 2348UPQ USE CASE:LAN/SAN ACCESS CONVERGENCE

56BRKARC-1222 56

Page 57: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Data Mobility Manager (DMM)

Page 58: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Cisco Data Mobility Manager (DMM)Migrating data across heterogeneous storage array with minimum disruption

SAN “A” SAN “B”Host I/Os

Data Migration

Existing Storage Pool

Server

New Storage Pool

BRKARC-1222 58

Page 59: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

DMM Synchronous

• Supports Dual Fabric Topology

• One DMM node in each Fabric

• DMM node performsMirroring for Server WRITE I/Os

Data movement for Migration

• Server HBA Port, Existing/New Storage Port needs to be in the same VSAN (per Fabric)

Existing Storage Pool

Server

New Storage Pool

MDS 9700

MDS 9700

MDS 9250iw/DMM

MDS 9250iw/DMM

BRKARC-1222 59

Page 60: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

DMM Asynchronous

• Additional Replication Fabric added for “out-of-band” copy

• One DMM node in each Production Fabric and one DMM node for Replication Fabric

• Replication DMM node copies data from existing Storage to new Storage with information provided by production DMM nodes.

• Replication SAN can be local (same Data Center) or extended between Data Centers (DWDM or FCIP)

Existing Storage Pool

Server

New Storage Pool

Replication SAN

MDS 9250iw/DMM

BRKARC-1222 60

Page 61: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Up to 16 TB LUN size

Up to 7680 LUNs

3.7 TB/hr Data Migration Throughput

Save Time: Resume job after WAN link failure

MDS DMM: Meeting SLAsFast Time To Completion Is Key

BRKARC-1222 61

Page 62: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

DMM Job Resumption after Failure

• WAN link fails due to failed nodes or bad links or CRC errors

• DMM Migration job needs to be restarted from beginning, loosing time

• With NX-OS 6.2(9) release, job resumes after WAN link recovery

Existing Storage Pool

Server

New Storage Pool

Replication SAN

Save time & effort and meet SLA requirementsBRKARC-1222 62

Page 63: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

I/O Acceleration (IOA)

Page 64: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Application Acceleration

• Distance between data centers impacts performance of disk replication and tape backups

• Latency introduced by distance is compounded by multiple round trips per command

• Different acceleration methods are available to accelerate data over distance

I/O Accelerator (IOA) for disk and tape over FC or FCIP

Write Acceleration for disk over FCIP (FCIP-WA)

Tape Acceleration for tape over FCIP (FCIP-TA)

BRKARC-1222 64

Page 65: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

WRITE-1

XFER_RDYXFER_RDY

STATUS

DATA

Tape Acceleration (TA)

STATUS

WRITE-2

XFER_RDY

DATA

STATUS

XFER_RDY

STATUS

WRITE-1

WRITE-2

WRT file mark

WRT file mark

WRT fm stsWRT fm sts

TA TAWRITE

XFER_RDYXFER_RDY

Write Acceleration (WA)

Reduction in I/O

Latency ~equal to one

round trip time (RTT)

STATUS

DATA

WA WA

Acceleration Data Flow Concepts

• Synchronous Replication and Tape Backup are Similar –both have one outstanding I/O

• Tape drives further impacted by limited buffering and physical media

• Write Acceleration spoofs Transfer Ready only, Tape Acceleration spoofs Command Status

BRKARC-1222 65

Page 66: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Replication IO Acceleration Use Cases

• Acceleration only works for replication or back-up protocols that use a SCSI write or SCSI-like write sequence with two round-trips

• EMC SRDF/s, SRDF/A, SRDF/AC, Mirrorview and SANcopy

• HDS TrueCopy

• HP CA-XP, CA-MVA

• IBM FlashCopy, FastT, XIV

• Protocols that use a single round trip do not require IO Acceleration

• EMC SRDF/S with SiRT enabled

• HDS Universal Replicator (HUR)

• HP CA-EVA

• IBM PPRC, PPRC-XD, XRC/Global Mirror, Metro Mirror

• NetApp Metro Cluster

BRKARC-1222 66

Page 67: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

• Port Based FCIP-WA and FCIP-TA only accelerate IOs egressing through their bound 1/10GE port

• Only works with FCIP

• Restrictions on HA topologies

• Accelerates all flows over a given FCIP interface

• Network Based IO Acceleration (IOA) accelerates any IO in the fabric over any ISL type

• No restrictions on HA topologies

• Can selectively accelerate flows based on PWWN of devices

• Both methods function the same at the SCSI layer

Port vs. Network Based Acceleration

BRKARC-1222 67

Page 68: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Comparison of Acceleration Methods

IOA-WA and IOA-TA FCIP-WA FCIP-TA

Attached Devices 1/2/4/8/16G 1/2/4/8/16G 1/2/4/8/16G

ISLs supported FC and FCIP FCIP FCIP

ISL Speed 1/2/4/8/10/16G 1/10GE 1/10GE

Port Channels Yes, up to 16 ISLs Yes, up to 16 ISLs No

Equal Cost Multi-Path Yes, up to 16 No No

Disk Acceleration Yes Yes No

Tape Acceleration Yes No Yes

BRKARC-1222 68

Page 69: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

FA RA

1) Server writes to disk

2) Local Array (I) writes to remote Array (T)

3) FCR switch redirects original flow I, T to IOA

engine (I, VT1)

RA FA

IOA

4) IOA accelerates flow and sends to remote IOA

engine over normal routing path (VI1, VT2)

5) Remote IOA engine changes flow to VI2, T

6) FCR switch change flow back to I, T

• IOA configured - Virtual Initiators and Virtual

Targets are created and distributed through

the fabric

• Virtual Initiators (VI) and Virtual Targets (VT)

are transparent to the end devices

• No changes to end devices or zoning required

IOAI,T

I,VT1

VI1,VT2

VI1,VT2

VI1,VT2

VI2, T

I,T

IOA Operation

BRKARC-1222 69

Page 70: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Site: rtp-bldg8Site: sjc-bldg6

FA RA RA FA

IOA Sites and Engines• IOA Site

A local set of switches within the fabric (e.g. sjc-bldg6)

• IOA Engine (interface)

Represents a Storage Service Engine within the MDS 9250i, MDS 9222i, SSN-16 or MSM-18/4

Ex. ioa2/1, ioa3/1-3/4

Note: a separate IOA license is required for each engine

IOA IOA

BRKARC-1222 70

Page 71: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Site: rtp-bldg8Site: sjc-bldg6

FA RA RA FA

IOA Clusters• IOA Cluster

A set of IOA engines in a pair of IOA sites that operate as one group to provide IOA service

E.g. switches S1, S2, S3 and S4

Automatic load balancing among engine pairs

A site can be in multiple clusters (bunker sites)

A switch can be in multiple clusters

Note: an engine is bound to only one cluster

IOA IOA

IOA IOA

S1

S2

S3

S4

Cluster 1

Site: bunker

IOA

IOA

BRKARC-1222 71

Page 72: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Site: rtp-bldg8Site: sjc-bldg6

FA RA RA FA

IOA Flows• IOA Flow

A flow accelerated within an IOA cluster

Each flow is identified by

{Initiator PWWN, Target PWWN, VSAN ID}

E.g. (DI1, DT1, V1) or (BI1, TT1, V1)

• IOA Flow Group

A set of IOA flows classified for a given purpose.

E.g. SRDF flow group and TSM flow group.

IOA IOADI1 DT1

BI2

TT1

BI1

BRKARC-1222 72

Page 73: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Ethernet Storage Networking

Page 74: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

New Application Design is EmergingIP Storage Trends Tracking these changes

BRKARC-1222 74

Page 75: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Resource sharing amongst multiple application workloads

Low latency high throughput networks for sensitive workloads

BANDWIDTH

LATENCY

SCALABILITY

HIGH AVAILABILITY

Meet the increasing demands of network and data without compromising fan out and performance

Hardware and software redundancy needed at the Server, Fabric and Storage levels

Design Considerations for IP SANS

BRKARC-1222 75

Page 76: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Workloads are increasing

demand on networks Increased Virtualization

Hyper-convergence

Image courtesy of the Ethernet Alliance: http://www.ethernetalliance.org/wp-

content/uploads/2015/03/Front-of-Map-04-28-15.jpg

Future technologies will drive

requirements further NVMe over fabrics

RoCE

iWARP

RDMA

Data Center Bandwidth Requirements

BRKARC-1222 76

Page 77: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

1 2

1 2 20

Probability of 100% throughput = 3.27%

Probability of 100% throughput = 99.95%

20×10Gbps

Uplinks2×100Gbps

Uplinks

11×10Gbps flows

(55% load)

On the Data Path Performance of Leaf-Spine Datacenter Fabrics - M. Alizadeh, T. Edsall:

http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6627738

BANDWIDTH = BETTER EFFICIENCYHIGHER SPEED LINKS IMPROVE MULTI-PATH EFFICIENCY

Higher speed links improve multi-path efficiency77BRKARC-1222 77

Page 78: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

3-Tier Network

L2

L3

Spine Leaf Network

L2/L3

LATENCYNETWORK DESIGN CONSIDERATION FOR LATENCY

78BRKARC-1222 78

Page 79: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Flexible Scalibility

………

………

Future Data Centers need

to be flexible Grow Vertically (racks)

Grow Horizontally (rows)

Scale Performance

Solution Architectures and

Infrastructure need to be

designed to meet these needs

from the start

BRKARC-1222 79

Page 80: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Typical Hierarchal Design – Dual

Networks for Redundancy If Network A path breaks all traffic

fails over to Network B

If a core switch goes down, the

entire Network A goes down

Impact of is failure high, so

greater requirement for

equipment HA

Typical High Availability

XX

BRKARC-1222 80

Page 81: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Spine/Leaf topology reduces

impact of failure XX

Spine

Leaf

Reduces impact of failure

Reduces dependency hardware

redundancy

Loss of path reduces edge switch

bandwidth fractionally

Loss of Spine does not take down

entire fabric, only fractional capacity lost

Rethinking High Availability

BRKARC-1222 81

Page 82: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Storage Networking Management

Page 83: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Data Center Components

Network:

Nexus and MDS Fabrics

Virtual Compute:

VMware

Storage Arrays:

FC Block Based Vendors

Compute:

Cisco UCSNetwork

Compute

Storage

BRKARC-1222 83

Page 84: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

AUTOMATE

CONFIGURE

VISUALIZE

DIAGNOSE

MEASURE

SC

AL

AB

LE

Simplified Operations of NX-OS

PR

OG

RA

MA

BL

E

Nexus and MDS Fabric Management Solution

BRKARC-1222 84

Page 85: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Slowdrain Analytics Automates Troubleshooting• Collects the whole fabric at once

Automates Collection• From hours of collection to minutes

Shows Fluctuations in counters• Graphs counters • Enables user to zero in on specific counters

Reduces False Positives • prioritizing ports highest severity counters

BRKARC-1222 85

Page 86: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Masking

DatabaseVSAN 2,10,12

SAN Host Path Redundancy AnalysisOn-Demand and Automated Redundancy Checks

Reduce

Mean Time to RepairRisk to Switch and Array

Upgrades

Risk to Hardware

Maintenance Activities

Enclosure

Port Down on

Redundant

Path

VSAN initiator

to target

Mismatch

VSAN

Segmentation

Both Paths On

Same Line

Card

Physical

Fabric

Separation

Host_Memoria

VSAN 10

VSAN 11

Nexus5000-FabA

Nexus5000-FabB

MDS9710-FabA

MDS9710-FabB

VSAN 3, 11

VSAN 10 Port A

VSAN 11 Port BVSAN 13 Storage

Array

LUN 1 > A/B

LUN 2 > A/B

LUN 3 > A

LUN 4 > A/B

Root

Cause

VSAN 3, 13

Port LUN

Masking

Mismatch

Fabric Separation

Fabric A

Fabric B

HBA1

HBA0

Page 87: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

N5K-access-71

N5K-access-70

M97-75

M97-74

Storage

Array

Visualize Hypervisor: VMware

End-to-End Visibility

Windows

2k8-R2-151.102

172.20.151.101

RedHat-151.103

VMsESX

UCSor GENERIC

SERVER

MDSor NEXUS ISL/FCIP MDS or NEXUS

STORAGE PORT

& LUN(s)

FC + FICON CNA Adapters

FCoE + iSCSI

• VM and ESX Inventory

• Monitor VM and ESX

CPU/Memory

• Monitor storage and

network traffic & Events

• Max Datastore Latency

• VM to DataStore

Mapping

Page 88: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

UCS-FI-6120XP MDS9710-16GBIT

Storage

Array

UCS-FI-6120XP MDS9710-16GBIT

Visualize Compute: Cisco UCS

End-to-End Visibility

Windows

2k8-R2-151.102

172.20.151.101

RedHat-151.103

VMsESX

UCSor GENERIC

SERVER

UCS FI or MDSor NEXUS ISL/FCIP MDS or NEXUS

STORAGE PORT

& LUN(s)

FC + FICONCNA Adapters

FCoE + iSCSI

• Mapping Service Profile

• Blade Inventory

• Module and Port view

Page 89: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Windows

2k8-R2-151.102

172.20.151.101

RedHat-151.103

Storage

Array

Visualize Virtual and Physical Fabrics

End-to-End Visibility

VMsESX

UCSor GENERIC

SERVER

MDSor NEXUS ISL/FCIP MDS or NEXUS

STORAGE PORT

& LUN(s)

FC + FICONCNA Adapters

FCoE + iSCSI

N5K-access-71 M97-75

N5K-access-70 M97-74

• Switch and Port Events

• Average & Peak TX/RX

• Switch CPU/Memory

• Performance monitoring

of ISLs, Trunks, FCIP

• Discards and Errors

Page 90: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

N5K-access-71 M97-75

N5K-access-70 M97-74

Windows

2k8-R2-151.102

172.20.151.101

RedHat-151.103

Visualize Storage Systems

End-to-End Visibility

VMs

ESX

UCS

or GENERIC

SERVER

MDS

or NEXUS ISL/FCIP MDS or NEXUS

STORAGE PORT

& LUN(s)

FC + FICONCNA Adapters

FCoE + iSCSI

Storage

Array

• Array port mapping

• Host to LUN mapping

• Array Capacity View

• Array Inventory

• Capacity Report

Page 91: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Configure: Wizards and Templates

Provision Virtual

Port Channel

Provision

Zone

StorageNetwork

Fabric Provisioning

• Wizards & Templates

OS Upgrade Wizard

Backup/Roll Back

Data Replication

FCIP IO Acceleration

BRKARC-1222 91

Page 92: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Diagnose

Database Crashes

Event Filtering and De-dup

Misconfiguration Analysis

Rule Based Fault Notification

Health Score

BRKARC-1222 92

Page 93: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Measure

Identify

Bottlenecks

Port Capacity Array Capacity

Identify Orphaned

PortsTop Array

Ports & Hosts

Port inventory

FORECAST

VIEW + REPORT CAPACITY and PERFORMANCE

BRKARC-1222 93

Page 94: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

DCNM Resources

http://cisco.com/go/dcnm

Videos

Release Notes

Datasheets

Configuration Guides

Installation and Licensing Guide

Programmable Guide

http://cisco.com/go/license

Evaluation and Permanent Licensing

License transfer to another DCNM server

BRKARC-1222 94

Page 95: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Wrap Up

Page 96: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Storage Networking for Agile Data Centers

Deploy Cisco MDS for Fibre Channel Storage Networks with Superior

Performance, Scale, and Architectural Flexibility

Enable Seamless Multi-protocol Fabrics with Nexus and MDS for highly efficient

architectures that can adapt to changing storage

requirements

Provision, Monitor, and Automate Physical and

Virtual Datacenters using integrated and third party cloud software platforms

BRKARC-1222 96

Page 97: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Complete Your Online Session Evaluation

Don’t forget: Cisco Live sessions will be available for viewing on-demand after the event at CiscoLive.com/Online

• Give us your feedback to be entered into a Daily Survey Drawing. A daily winner will receive a $750 Amazon gift card.

• Complete your session surveys through the Cisco Live mobile app or from the Session Catalog on CiscoLive.com/us.

BRKARC-1222 97

Page 98: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Continue Your Education

• Demos in the Cisco campus

• Walk-in Self-Paced Labs

• Table Topics

• Meet the Engineer 1:1 meetings

• Related sessions• BRKSAN-2883 - Advanced Storage Area Network Design

• BRKSAN-3101 - Troubleshooting Cisco MDS 9000 Fibre Channel Fabrics

• BRKSAN-3446 - SAN Congestion! Understanding, Troubleshooting, Mitigating in a Cisco Fabric

• PSOSAN-1089 - Cisco Storage Networking: Linking Technology and Innovation to Solve Business Problems

• BRKVIR-1121 - Fiber Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices

BRKARC-1222 98

Page 99: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Please join us for the Service Provider Innovation Talk featuring:

Yvette Kanouff | Senior Vice President and General Manager, SP Business

Joe Cozzolino | Senior Vice President, Cisco Services

Thursday, July 14th, 2016

11:30 am - 12:30pm, In the Oceanside A room

What to expect from this innovation talk

• Insights on market trends and forecasts

• Preview of key technologies and capabilities

• Innovative demonstrations of the latest and greatest products

• Better understanding of how Cisco can help you succeed

Register to attend the session live now or

watch the broadcast on cisco.com

Page 100: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

© 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public

Data Center / Virtualization Cisco Education OfferingsCourse Description Cisco Certification

Introducing Cisco Data Center Networking (DCICN);

Introducing Cisco Data Center Technologies (DCICT)

Learn basic data center technologies and skills to build a

data center infrastructure.

CCNA® Data Center

Implementing Cisco Data Center Unified Fabric (DCUFI);

Implementing Cisco Data Center Unified Computing (DCUCI)

Designing Cisco Data Center Unified Computing (DCUDC)

Designing Cisco Data Center Unified Fabric (DCUFD)

Troubleshooting Cisco Data Center Unified Computing

(DCUCT)

Troubleshooting Cisco Data Center Unified Fabric (DCUFT)

Obtain professional level skills to design, configure,

implement, troubleshoot data center network infrastructure.

CCNP® Data Center

Product Training Portfolio: DCNMM, DCAC9K, DCINX9K,

DCMDS, DCUCS, DCNX1K, DCNX5K, DCNX7K

Gain hands-on skills using Cisco solutions to configure,

deploy, manage and troubleshoot unified computing, policy-

driven and virtualized data center network infrastructure.

Designing the FlexPod® Solution (FPDESIGN);

Implementing and Administering the FlexPod® Solution

(FPIMPADM)

Learn how to design, implement and administer FlexPod

solutions

Cisco and NetApp Certified

FlexPod® Specialist

For more details, please visit: http://learningnetwork.cisco.com

Questions? Visit the Learning@Cisco Booth or contact [email protected]

BRKARC-1222 100

Page 101: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical

Thank you

Page 102: Cisco MDS/Nexus SAN Portfoliod2zmdbbm9feqrf.cloudfront.net/2016/usa/pdf/BRKARC-1222.pdf · Cisco MDS/Nexus SAN Portfolio: Next phase of Storage Networking Mark Allen –Technical