© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco PublicCisco Confidential© 2010 Cisco and/or its affiliates. All rights reserved. 1
Cisco Data Center Training for IBMChanging the Economics of the Data Center
Brent AndersonSystems Engineer – DataCenter
IBM - Global
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Business Challenges
BudgetConstraints
Security andCompliance
24x7 BusinessBusiness
Agility
Technology Trends
Cloud Data DelugeProliferationof Devices
Energy Efficiency
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
AT&T transfers about 30 Petabytes of data through
its network daily
150 Exabytes global size of “Big Data” in Healthcare, growing
between 1.2 and 2.4 EX / year
Facebook processes 500+ Terabytes of data daily
By 2016, annual Internet traffic will reach 1.3 Zettabytes
$155B Worldwide sensor market in 2011, forecasted to grow to $240B in
2016
450B Business transactions / day over the Internet by 2020
118B E-mails sent daily from a total of 3.4B e-mail accounts;
volume growing to 168B in 2015
6.8B Mobile phones worldwide
Increasing Demands on IT…
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco PublicSource: IBM Global Technology Outlook, 2012
2010 2015
Percentage of Uncertain Data
You are here.
Sensors & Devices
VoIP
Enterprise Data
Social Media
1023
Data Growth: This is only the beginning!
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Source: IDC, Storage Purchasing Trends Among US Firms, IDC QuickPoll Survey, July 2013, Doc # 243511
© IDC, Visit us at IDC.com and follow us on Twitter: @IDC
2.6
23.8
26.4
28.0
28.3
30.9
42.0
.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
Other
Complexity in managing too many storage product architectures
Quickly fulfilling storage provisioning requests
Time in planning/doing storage migrations/technology refreshes
Time and/or budget to implement advanced storage features
Successfully troubleshooting potentially storage-related problems
Meeting SLAs on performance, availability or recovery
Most Pressing Storage Challenges
% of respondents
Businesses Must AdaptExcluding data growth, Satisfying SLAs is their Top Imperative / Challenge
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
CiscoNexus 5000
CiscoNexus 6000
CiscoNexus 7000
Cisco Nexus 1000V
CiscoNexus 3000
Cisco MDS 9200 Series
Cisco® MDS 9500 Series
Cisco MDS 9100 Series
CiscoNexus 2000
10+ Years of Proven NX-OS Operating System From Hypervisor to Core
Cisco Multi-Protocol Architecture for LAN and SAN
Industry’s Broadest Switching Portfolio
CONSISTENT and SIMPLIFIEDFeatures, Management and Programmability
Cisco Prime Data Center Network Manager (DCNM) Single Point of Management
B22
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Multi-Protocol Storage Networking
© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 8
FCHigh
Performance Data Center Connectivity
FICONMainframe
Connectivity
FCIPLong Distance
Replication Connectivity
iSCSI-NAS
File and Block Over IP
TCP/IPLAN Connectivity
FCoE
SAN Protocols
LAN Protocols
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Multi-Protocol Storage Networking
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Mainframe: LPAR, z/VM, Z-Linux
IBM AIX: LPAR, VIO, P-
Hypervisor, Converged I/O
IBM X86: Hypervisor (ie
Vmware,KVM, HyperV), Blade
Chassis I/O consolidation,
Converged I/O
Cisco MDS with
VSANs, IVR,
NPiV, NPV
Enhanced Ethernet and FCoE FCiP FC
IBM SAN Volume
Controller
Virtualized Disk of DASD
systems
VDISK VDISK
SVC
Multi-Protocol Support
TEST
VSANs
DEV VSAN
Prod. VSAN
WAN
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Cisco Extends SAN Intelligence to Virtual Server Deployments
Fabric Scalability and PerformanceResilient, high performance fabric to support
large, dense VM environments
Performance Monitoring and TrendingVM-granular management and troubleshooting
Quality of Service (QoS)VM-granular policy provisioning
VSANs Isolate Fault DomainsIncrease availability, simplify
troubleshooting, improve security
Long Distance vMotionSeamless migration of applications
between data centers
Tier 1 Tier 2 Tier 3
SAN Fabric
V V V
NPIVV V V
V V V
V V V
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
The MDS architecture has been designed to meet the following principles:
• High Data Transfer Capability – Provide performance to meet customer requirements
• Predictable Performance – All traffic in chassis has equal and consistent performance no matter traffic ingresses or egresses
• Highly Available – Hardware components and Software features are design for maximum availability
• Data Protection – Protect SAN and End devices from corrupted frames
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
THE OF ANY DIRECTOR
NOW!STORAGE DIRECTOR
INDUSTRY’S MOST
WITHINNOVATIONS
UNMATCHED
INVESTMENT PROTECTION for the Next Decade!
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
SCALEFOR ANY SAN
Up to 384 Line Rate ports with
48x16G FC or 48x10G FCoE
GROWWITHOUT FORKLIFT
1.5-Tbps/slot capacity
3X thePERFORMANCE of any
Director
MDS 9710 Director –Future-Proofing
For Cloud and Massive Amounts of Data
With
Q1 CY14NOW
PRESERVEIT OPERATIONS and KNOWLEDGE
Ease of migration
With NX-OS and DCNM
CONSISTENTOPERATIONS
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
The MDS 9710 is the next generation Fibre Channel Director from Cisco, designed for:
• Highest Scalability in the Industry
‒ 50% more Line-rate 16G FC Ports than competition
• Highest Availability in the Industry
‒ N+1 Fabric Modules protection1 provides zero impact to Application Bandwidth in the event of a fabric card or supervisor card failure
• Investment protection for the next decade
‒ Three times backplane bandwidth2 than competition
1 With optional fourth fabric module installed2 With six fabric modules installed
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
MDS 9710 Chassis
Supervisor Engine
Fabric
Module
48 Port 16G Line Card
Fan Tray
48 Port 10GbE FCoE Module
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
48-Port 16G Fibre Channel Line Card
Cisco 16-Gbps Line Card
Performance 48 x 16 Gbps ports, 768 Gbps
Port Speeds 2, 4, 8, 10 and 16 Gbps Fibre Channel
Optics (sfp+) 2/4/8G FC, 4/8/16G FC, 10G FC, 10GE (FC with 10GE clock)
Port Types F, FL, E, TE, SD, ST
Port Groups Twelve 4-port port-groups
Intelligent Capabilities VSAN, IVR, FC Redirect
Buffer-to-buffer credits Up to 500 per port, 4095 with Enterprise License (510km @ 16G)
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
MDS 9710 PIDs Distance
16G FC SFP+DS-SFP-FC16G-SW
• OM1 -15M, OM2 – 35M
• OM3 – 100M, OM4 – 125M
DS-SFP-FC16G-LW • 10 km
8G FC SFP+
DS-SFP-FC8G-SW• OM2 -100M, OM3 – 150M
• OM4 – 190M
DS-SFP-FC8G-LW • 10 km
DS-SFP-FC8G-ER • 40 km
10G FC SFP+DS-SFP-FC10G-SW
• OM1 – 33m, OM2 – 82 m, OM3 – 300
m
DS-SFP-FC10G-LW • 10 km
10GE SFP+
SFP-10G-SR • 300 m
SFP-10G-LR • 10 km
SFP-10G-ER • 40 km
8G CWDM* DS-CWDM8G-xxxx• 25 km with CWDM Mux and Demux
• 40 km point to point
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public1
9© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential
MDS 9710 48-Port FCoE ModuleSeamless Bridge FC SANs to Converged Networks
Use-cases Create FCoE ISLs between N7K/MDS
Bridge Converged Networks to FC SANs
Enabling services such as FCIP to Converged Networks
High-density (48-Port) Line Rate FCoE Module
Supported in any MDS 9700 chassis
BenefitsPreserves existing and continued investments in MDS 9700 FC
Seamless interoperability between all MDS 9700 and Nexus platforms
Preserve existing and continued investments in Fibre Channel
48-port 10-Gbps FCoE Line CardMDS 9700 Chassis
Q2’14
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Now With FICON SupportMDS 9710
FICON | FCP | CASCADING | VSAN | CUP
Preparing FICON topologies for 16Gbps and 32Gbps channels
© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 21
MDS 9710:
Multi-hop FCoE:
http://www.cisco.com/en/US/solutio
ns/collateral/ns340/ns517/ns224/un
iversity_of_siegen_external_casest
udy_fnl_01_30_13.pdf
http://www.cisco.com/en/US/
solutions/collateral/ns340/ns5
17/ns224/boeing.pdf
http://www.cisco.com/en/US/solutions/col
lateral/ns340/ns517/ns224/NetApp_exter
nal_casestudy_fnl_04_15_13.pdf
http://www.cisco.com/en/US/s
olutions/collateral/ns340/ns51
7/ns224/itochu_cs.pdf
http://www.cisco.com/en/US/solutions/collateral/ns340/
ns517/ns224/mds-linkedin-cs-11_08_13.pdf
http://www.cisco.com/en/US/solutions/collateral/ns3
40/ns517/ns224/molina_cs_10_31_13_final.pdf
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• Each Fabric Module provides 220 Gbps of actual data bandwidth per slot, equivalent to 256 Gbps of Fibre Channel apparent bandwidth
• Three fabric modules provide 660 Gbps of actual data bandwidth per slot, equivalent to 768 Gbps of Fibre Channel apparent bandwidth
• With six fabric modules, the maximum per slot bandwidth is 1.32 Tbps of actual data bandwidth OR 1.536 Tbps Fibre Channel apparent bandwidth
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Number of Fabric
Cards
Front panel FC Bandwidth
per Slot/ Total BandwidthFull Line-Rate N+1 Fabric Card Protection
1 256 Gbps No No
2 512 Gbps No No
3 768 Gbps Yes No
4 768 Gbps/1024 Yes Yes
5 1280 YES YES
6 1512 YES YES
Host Port
Line-rate on 48-port 16G FC Module needs only 3 Fabric cards
48 Port 16G FC Module
Switching Bandwidth per fabric card
1
2
3
432Gbps
FC ready
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfCRModules
PossibleFront-PanelBandwidthPerSlot
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfFabricCards
PossibleFront-PanelBandwidthPerSlot
Cisco MDS vs Brocade – 3x Performance
Number Of Fabric
Cards
Front-Panel FC
Bandwidth / Slot
1 256 Gbps
2 512 Gbps
3 768 Gbps
4 1024 Gbps
5 1280 Gbps
6 1536 Gbps
Number Of CR
Modules
Front-Panel FC
Bandwidth / Slot
1 256 Gbps
2 512 Gbps
Cisco MDS
9710
Brocade DCX
8510
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfFabricCards
PossibleFront-PanelBandwidthPerSlot
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfFabricCards
PossibleFront-PanelBandwidthPerSlot
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfFabricCards
PossibleFront-PanelBandwidthPerSlot
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfFabricCards
PossibleFront-PanelBandwidthPerSlot
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfFabricCards
PossibleFront-PanelBandwidthPerSlot
Future Proof
Growth
0
256
512
768
1024
1280
1536
1 2 3 4 5 6
Band
width-Gb
ps
NumberOfCRModules
PossibleFront-PanelBandwidthPerSlot
Future Proof with MDS 9710 for 32G FC and 40G FCoE
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
3X Less Latency – any port to any port
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
14 RU
MDS 9710Standard
ConfigurationMax Configuration
Line Cards 8
Supervisor Modules 2
Fabric Modules 3 6
Power Supplies 6 8
Fan Trays 3
Chassis Height 24.35” (14 RU)
Chassis Width 17.3”
Chassis Depth 34"
Line-rate 16G Ports/system 384
Airflow Front-to-Back
17.3”
MDS 9710 Director Highlights
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
MDS 9710 Details
Redundant Supervisor
Engines
8 payload slots
(1.5T/slot)
8 3000W AC/DC power
supplies
14RU
3 fan trays
6 fabric modules
(behind fan trays)
RearFront
Front-to-back airflow
32”
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• New form factor 3000W power supply module
• Autosensing voltage detection
• Both AC and DC power supplies available
• Can mix AC and DC power supplies in same chassis
MDS
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• Maximum MDS 9710 configuration requires 3 power supplies to operate
• Six power supplies provide grid redundancy, three per power grid
Grid A Grid B
Power Distribution Unit-B
Power Distribution Unit-A
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• New half-width form factor
• 10/100/1000 Management port, RJ45 Console port, 2 x USB 2.0 ports
SUP2A
MDS 9500
SUP
MDS 9710
Memory 2G 8G
# of Cores 1 4
Clock Speed 1.4 GHz 2.1 GHz
Instruction 32-bit 64-bit
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
MDS 9710 MDS 9513
Maximum Ports Per Chassis384 x 2/4/8/10/16-Gbps FC
384 x 10-Gbps FCoE1
528 x 1/2/4/8/10-Gbps FC
88 x 10-Gbps FCoE
176 x 1-Gbps Ethernet
Line Card Slots 8 11
Supervisor Slots 2 2
Switching Fabric Slots 62 2
Switching Fabric 256 Gbps FC per fabric 128 Gbps FC per fabric
FC Switching Bandwidth 24-Tbps 8.4-Tbps
Physical Dimensions
(H x W x D)24.5 x 17.37 x 34.0 in. 24.5 x 17.37 x 28.0 in.
Physical Dimensions (RU) 14 14
Weight
Chassis - 185 lbs
Power supply - 6 lbs
Fabric module - 11 lbs
Supervisor-1 - 7 lbs
Chassis - 100 lbs
Power supply - 32.5 lbs
Fabric module - 5.75 lbs
Supervisor-2/2A - 7.2 lbs
Airflow Front to back Side to side
Fan Tray Three fan trays at back Front and back fan tray
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
MDS 9000 Portfolio
Gen-1 (2Gb)
Supervisor-1
MDS 9506 & 9509
IPS-8
FC-32
FC-16
SSM
MPS -14/2
MDS 9216 & 9216i
Gen-2 (4Gb)
12/24/48-port 4Gb FC
MSM-18/4
Supervisor-2/2A 4-port 10Gb FC
MDS 9222i
MDS 9513
MDS 9124 & 9134
Gen-3 (8Gb)
24/48-port 8Gb FC
4/44-port 8Gb FC
SSN-16
Fabric-2
MDS 9148
EOLGen-4
8Gb FLR
4/44-port 8Gb FC
SSN-16
Fabric-3
MDS 9148
32-port 8Gb FLR FC
48-port 8Gb FC
Fabric-3
EOS
Cisco Confidential© 2013 Cisco and/or its affiliates. All rights reserved. 34
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Ethernet1 2 3 4 5 6 7 8
MDS 9250i Multiservice Fabric SwitchNext-Gen Storage Services Platform for Unified FabricFCiP | FC | FICON | iSCSI | FCoE
Features
Line Rate Performance for
• 16G FC, 10GE FCoE, 10GE FCIP, FICON, iSCSI
Rich set of Storage Services for FC and FCoE SANs
• FCIP, IO Accelerator (IOA), Data Mobility Migration (DMM),
Integrated Management via Data Center Network Manager (DCNM)
Benefits
Single Platform for deploying Storage Services across FC and FCoE Storage Area Networks (SANs)
• High-Bandwidth SAN Extension across MAN/WAN
• Migrate Data between FC and FCoE arrays
MDS 9250i
40 Ports 16G FC 8 Ports 10GE FCoE
2 Ports 10GE FCIP/iSCSI 1+1 Redundant Fans
2+1 Redundant Power Supplies
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
DATA MIGRATION
Migrate Data between
Heterogenous Arrays
BUSINESS CONTINUITY/DISASTER RECOVERY
16G FIBRE CHANNEL SWITCH FC TO FCOE GATEWAY
MDS 9250i
IP WAN
MDS 9250i
NexusMDS
9710
10G FCIP
FC
MDS 9250i
DWDM/
SONET
Optical
MAN
FC
FCoE
MDS 9250i
FCoE
FC FCoE
Nexus
Nexus
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• SAN Extension is an integral component of SAN Business Solutions:
‒ Disaster Recovery – Protecting Data Through Offsite Data Replication and Backup
‒ Business Continuance – Restoration of Business After a Failure
‒ Business Resilience – Continued Operation of Business During a Failure
‒ Cloud Storage – Leveraging the Cloud for Data Storage
• Solution dependent on available DCI network and the customer business requirements (RPO, RTO)
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• SAN Extension solutions typically divided into the following categories:
Solution Solution FC FCoE FCIP
Dark FiberReplication -
Synchronous1, 2, 4, 8, 10, 16G 10GE 1, 10GE
CWDMReplication -
Synchronous1, 2, 4, 8 10GE 1, 10GE
DWDMReplication -
Synchronous1, 2, 4, 8, 10G 10GE 1, 10GE
SONET/SDH
Replication –
Synchronous /
Asynchronous,
Backup
1, 2, 4, 8, 10G NA 1, 10GE
FCIP
Replication –
Asynchronous,
Backup
NA NA 1, 10GE
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• SAN Extension distance is limited by two separate factors
‒ Physical Layer – How far can the optics transmit or how far does the interconnect go (dependencies on cable type and speed)?
‒ SW optics – < 1 km,
‒ MR optics – up to 4 km
‒ LW optics – up to 10 km
‒ ER optics – up to 40 km
‒ CWDM/DWDM optics – up to 40 km point-to-point
‒ Flow control – How many frames can I have in flight?
‒ FC – Determined by BB credits
‒ FCoE – Determined by interface buffers
‒ FCIP – Determined by the TCP window size
• It is the combination of these two factors that determines how far a FC solution can be deployed
Cisco Confidential© 2013 Cisco and/or its affiliates. All rights reserved. 40
Cisco Prime
Data Center Network Manager
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public4141
• Device level configuration via Cisco CLI or Device Manager application
• Initial product configuration• VSAN configuration• Port configuration
• Manager SNMP security access• Manage alarms, events and notifications
• View chassis, module, port status
• Fabric wide configuration via DCNM SAN (Java)
• Fabric wide configuration of port channels, FCIP, VSANs, etc• Topology view
• Event monitoring• Fabric trouble shooting tools
• Wizard-based fabric provisioning: verify changes before execution and reduce chances for human error
• Real-time event forwarding for proactive storage network management and reduced response time
MDS Management
IBM System Networking
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public42
The Summary Dashboard is configurable to display choices include: Health, Inventory, Traffic Flows, Connectivity, Used/Remaining Capacity
Cisco Data Center Network Manager AdvancedKey Feature: Dynamic Dashboards
IBM System Networking
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public43
• VMpath
VM connectivity to network and storage
• Standard & Custom Reports
• Provisioning NX-OS features
• Dynamic Topology Views
• Image Management
• Configuration Backup/Restore
• Rule-based event filtering and forwarding
• Threshold Alerting
• Change Tracking and RBAC
Cisco Data Center Network Manager AdvancedFeature Support and User Interface
IBM System Networking
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public44
VMpath: End to End Performance Management
• Troubleshoot Performance across virtualized compute and network domains
• Understand the Impact of the path outage along with event description
• Understand behavior of your applications over a period of time
VM SERVERNEXUSSWITCH
TRUNK / ISLSTORAGE
PORTMDS
SWITCH
IBM System Networking
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Click here for CLI Access
Select switches to open and common
credential
Reduces risk when upgrading
switch and storage arrays
Prevents outages due to missing
redundancy
Reduces time to migrate and
deploy infrastructure
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
SAN Host Path Redundancy Analysis
What it looks for
• Identifies non-redundant hosts
• Exceptions policy for single path hosts
• Optional storage array LUN check
• Fix recommendation
• Description of violation
• Supports FC and FCoE
• Runs every 24 hours or on demand
MDSN77
N5K
STORAGE
SERVER
VMWARE
N5K MDS
STORAGE
MDS
MDS
MDS
Missing Zone
Time
Port Down on redundant fabric
VSAN mismatch
VSAN segmentation
LUN visible through a single fabric only
MDS
MDS
© 2013 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 51
• The snooze feature will prevent forwarding of configured alerts
during specified time range.
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• Scaling work being done in 6.2(7) and beyond allows for greater flexibility in large scale SANs, especially for NPV environments
Feature 6.1(1) - 6.2(5) 6.2(7)
Phase-1
Gibraltar (7.x)
Phase-2
Flogi per line card 500 1000 1000
Flogi per NPIV core switch 2500 4000 4000
Zone members 16000 30000 30000
Zones 8000 16000 16000
Logins per fabric 10000 20000 20000
FCNS entries per fabric 10000 20000 20000
No of Domains 60 60 80
NPV switches/ NPIV Core Switch 105 105 105
Device Alias 8000 8000 20000
No. of VSANs per fabric 80 80 80
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Fault Tolerance in SANs
Addressing Misbehaving Devices
• Port Guard – Shutdown the link after multiple errors
Configurable thresholds (number of errors and duration)
• Slow Drain Devices – Detect, Notify, Recover
Detect - Monitor buffer credits and ASIC queues
Notify - SNMP traps and System Logs
Recover – Configurable multi-step recovery options
Disable the port right away
Attempt to recover through timeouts and frame-drops first
Misbehaving HBA
Affected Host
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Port-Guard The Link failure can happen for any of the following reasons.
- Cable cut (NOS/LOS)
- In case of F ports, the connected device has rebooted
- In case of ISL, the connected line card has rebooted
- Too many bit errors due to bad SFP/Cable etc.
- B2B buffer overflow condition
- Hardware Recoverable errors
Once the condition is hit the link will be down with the ‘Error disabled - port down due to link failure’ as the reason. This reason will also be displayed in the ‘show interface’ command.
User will need to perform the following to bring the link up again.
- ‘shut’ command followed by ‘no shut’ command
- Note: By default, irrespective of if this feature is enabled or not, we shut down the port if the switch receives too many invalid flogi’s from a host.
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Port-Guard config using Device Manager
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Cisco Nexus B22 Fabric Extender for IBM
• Extends FEX connectivity into blade chassis
• Cisco Nexus 5500/6000 Switch is a single management point for all the blade chassis I/O modules
• End-to-end FCoE support
• 50% decrease in blade chassis I/O modules
• 66% decrease in blade management points
• Blade & rack networking consistency
• Increased network resiliency
FEATURES
BENEFITS:
Cisco Nexus B22
IBM
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Cisco Nexus 2000 Series Fabric Extender
+
Cisco Nexus Parent Switch
Nexus 2000 Fabric Extender
Virtual Modular System
=
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public 6565
Nexus 5500 Series
FEX parent switch upgrade
Enhances POD with Layer 3 Intelligence
Enables Cisco Fabric Path
50% Reduction in Latency
40G Ready (future)
Scales to 1,000 hosts and 4K VLANs
Nexus 5500 + Nexus 2000
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Key Feature Cutlass
Number of Ports 14 Internal server ports
8 External FET or SFP+ ports
Speed 1/10Gb internally; 10 Gb externally
Chassis management through I2C only; switch
management through upstream Top of Rack Switch
No CLI
No Configuration
No Ethernet NIC
Minimal CMM interaction
No apparent FSM interaction
No SNMP or MIB support (though Director and FSM
can interrogate CMM and upstream switch through
standard Nexus supported interfaces)
Max Computed Power 65.05w
FEX details
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Part Number information
The part number for the B22 Fabric Extender includes the following items:
• One Cisco Nexus B22 Fabric Extender
• Sixteen Cisco Fabric Extender Transceivers (Cisco part number FET-10G included only in 94Y5355)
• Important Notices Flyer
• Technical Update Flyer
• Warranty Flyer
• CRU/FRU Flyer
• Documentation CD-ROM
Note: Cisco Nexus B22 Fabric Extender, part number 94Y5350, comes without SFP or SFP+ (small form-
factor pluggable plus) transceivers or cables. They must be ordered separately.
Sold Exclusively by
IBM and its Partners
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Fabric Extender Connectivity Options
Fabric Extender Transceiver (FET)
• Cost-effective N5K->N2K interconnect
• SFP+ form-factor
• Reach of 100M (OM3 fiber)
• Incompatible with SR optics
• Used for N2K interconnect only
• Low power & latency
Single Reach (SR)
Long Reach (LR) Direct Attached Copper (Twinax)
Fabric Extender Transceiver (FET)
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Supported Adapters
* The Embedded 10Gb Virtual Fabric Adapter is included in models of the x240 with model numbers of the form x2x.
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
Connecting to Cisco network - Customer already owns Nexus ToR
LOM or CN4054
(pNIC, vNIC mode)
V7000
B22 Cisco FEX
Key value:
• Integrated Virtual Fabric and FCoE on compute node
• Cisco FEX in chassis - unmanaged
• Connects to existing or new Cisco network.
Black line is FCOE
Red line is Fibre Channel
Yellow line is Ethernet
Cisco
SAN
Nexus 55XX
Nexus 55XX
Adapter Integrated Switch FCoE Top Of Rack Switch SAN Switch Storage Target OS levels
LOM & CN4054 4-port adapter
(BE3) pNIC and vNIC modes
B22 Cisco FEX Nexus 5548 / 5596 Cisco SAN FC: V7000, SVC, DSXXX Win2008 R2SP1, ESX 5.0 U1,
RHEL 6.3
Nexus7K
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
FEX Parent - Cisco Nexus 5548UP & 5596UP
Mgmt 0, Console,
USB
Redundant Fan
Modules
Redundant 750W AC
Power Supplies
• Fixed Unified Ports
• Line Rate
• 1/10GE & FCoE
• 8/4/2/1 Native FC
Expansion Module
• 16p Unified Ports
Back of the Switch
Front to Back AirflowFront of the
Switch
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
FEX Parent - Nexus 6004 Chassis
12 QSFP ports
Expansion Module48 Fixed QSFP Interfaces
4RU
30”
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
FEX cable support plan – IBM cables
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
FEX cable support plan – Cisco cables
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
IBM and Cisco: How to design a state-of-the art data center and
networking infrastructure combining Cisco and IBM solutions
IBM and Cisco Building Blocks for the Data Center
Physical Access Layer Evolution
Cisco Virtual Networking Solutions
Convergence of LAN and SAN
DCN Management and Automation
SDN and Cisco ONE
Reference Designs for Small, Medium and Large
DCs
Link to Redbook:
http://www.redbooks.ibm.com/redpieces/abstracts/sg248105.html?Open
75
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
• Hardware
‒ 48-port 16G FC fixed fabric switch
‒ 1RU with field replaceable redundant power supplies and fans, with B2F air flow
‒ 10/100/1000 Ethernet, USB, and serial console for management access
‒ Base configuration of 12, 24, or 48 active ports
• Software
‒ NX-OS SAN 7.x release
• Licenses
‒ 12-port port upgrade license
Q3CY14
© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 78
6.2(1)Scope: MDS-9710
6.2(9)Scope: 16G
1RU, FC Scale, 9710 CTS
6.2(5) Scope: MDS
9250i, Pathtrace
6.2(3)Scope: bug fix release, plus
FCR, CLI
* Not engineering committed
Helsinki*Scope: 9706, OnePK, TBD
6.2(7)Scope: FCoE on 9710, FC Scale,
16G FEC
6.2(2) FCoE: F2-NG (N7710/N7718)
6.2(6)FCoE with Ethernet
vPC
Gibraltar 7.0(2)FCoE over FEX on F2,
FCoE on F2E (N7706) , FCoE Scale, FCoE over FabricPath Spine
Nexus 7000Helsinki*FCoE on F3 (10G/40G)
5.2(8c)Scope: Bug fixes
5.2(8a)Scope: Bug fixes
5.2(8b)Scope: Bug fixesMDS
Q3 CY13 Q4 CY13 Q1 CY14 Q2 CY14 Q4CY14Q3 CY14
6.0(2)N1(1)N6004 w/ 12p 10/40GE LEM, FCoE 10G Base-T
(N5596T), N2248PQ
Illuka (Maint.) 7.0(1)N1(1)20P 8G/10GE UP LEM (N6004), Nexus 56128, Nexus 5672UP, FCoE
over FabricPath
6.0(2)N1(2)N6001P, iSCSI
TLV (N5x)
Illuka (Plus)* 7.1.x16G FC GEM (N6K)
FCoE over DFA (Leaf/Spine), 4-port VFC, IVR, Smart Zoning, FCoE with
Switch-to-Switch vPC, FCoE Slow Drain (N6K)
Illuka 7.0(0)N1(1)FC Slow Drain and Port Monitor
(N55xx), FCoE Slow Drain (N55xx, N55xx w/ FEX), VFC
Scale, iSCSI TLV (N6K)
Nexus Fixed
Q2 CY13Q1 CY13
© 2012 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
New White Papers
Large Scale Design Best Practices
Using Cisco MDS 9500 Series and
9710 Multilayer Directors
Large Scale Design Best
Practices Using Cisco 9710
Multilayer Directors
Slow Drain Device Detection
and Congestion Avoidance
Design SANs with Detailed Best Practices Guides