Circuit Breaker Identification Matrix

6
July 2006 1 0100DB0602 CIRCUIT BREAKER IDENTIFICATION MATRIX NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included. Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces Notes Customer UL (489) ANSI (UL1066) C37 IEC (60947-2) Tradename Frame Catalog Reference Masterpact NT NT 1200 ICCB 800 LV PCB 1600 Air CB/PCB M, MP, MC (Masterpact), SE<800A, 800–1200A, DS206_H Fixed/Drawout 3-pole and 4-pole Masterpact NW NW 6000 ICCB 5000 LV PCB 6300 Air CB/PCB M, MP, MC (Masterpact), SE>1200A, all SEH, DS (except DS206_H) Fixed/Drawout 3-pole and 4-pole Powerpact (Powerpact C) C-frame CG, CJ 250 MCCB X (dual rated) Same as Compact NSF 3-pole and 4-pole Compact NSF NFN, NFH, (Square D brand labeled) 250 MCCB X (dual rated) Compact NSF will transition to the H- and J-frame (15–250A) Same as Powerpact C-frame 3-pole and 4-pole Powerpact (Powerpact D) D-frame DG, DJ, DL (Square D brand labeled) 600 MCCB X (dual rated) Same as Compact NSJ 3-pole and 4-pole Compact NSJ NJN, NJH, NJL X (dual rated) 630 MCCB Same as Powerpact D-frame 3-pole and 4-pole Powerpact GJL GJL (Square D brand labeled) 100 MCCB X (dual rated) 3-pole Compact NSE NEN, NEH 100 MCCB X (dual rated) 3-pole Masterpact NT Masterpact NW C-frame NSF D-frame NSJ GJL NSE

Transcript of Circuit Breaker Identification Matrix

Page 1: Circuit Breaker Identification Matrix

July 2006

0100DB0602

Notes

• Fixed/Drawout• 3-pole and 4-pole

• Fixed/Drawout• 3-pole and 4-pole

• Same as Compact NSF• 3-pole and 4-pole• Same as Powerpact C-frame• 3-pole and 4-pole

• Same as Compact NSJ• 3-pole and 4-pole

• Same as Powerpact D-frame• 3-pole and 4-pole

• 3-pole

• 3-pole

1

CIRCUIT BREAKER IDENTIFICATION MATRIX

NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.

Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces

Customer UL(489)

ANSI(UL1066)

C37

IEC(60947-2)

Tradename Frame Catalog Reference

Masterpact NT NT 1200ICCB

800LV PCB

1600Air CB/PCB

M, MP, MC (Masterpact),SE<800A, 800–1200A, DS206_H

Masterpact NW NW 6000ICCB

5000LV PCB

6300Air CB/PCB

M, MP, MC (Masterpact),SE>1200A, all SEH,

DS (except DS206_H)

Powerpact(Powerpact C)

C-frame CG, CJ 250MCCB

— X(dual rated)

Compact NSF NFN, NFH,(Square D brand

labeled)

250MCCB

— X(dual rated)

Compact NSF will transition to theH- and J-frame (15–250A)

Powerpact(Powerpact D)

D-frame DG, DJ, DL(Square D brand

labeled)

600MCCB

— X(dual rated)

Compact NSJ NJN, NJH, NJL X(dual rated)

— 630MCCB

Powerpact GJL GJL(Square D brand

labeled)

100MCCB

— X(dual rated)

Compact NSE NEN, NEH 100MCCB

— X(dual rated)

Masterpact NT

Masterpact NW

C-frameNSF

D-frameNSJ

GJLNSE

Page 2: Circuit Breaker Identification Matrix

July 2006

0100DB0602

ag A, d,

• Toggle Mechanism• 3-pole and 4-pole

• Toggle Mechanism• 3-pole and 4-pole• Drawout P-frame with toggle mechanism• 3-pole and 4-pole• Drawout P-frame with toggle mechanism

or with motor operator• 3-pole and 4-pole• P-frame with motor operator• 3-pole and 4-pole• P-frame with motor operator• 3-pole and 4-pole• Toggle Mechanism• 3-pole• Released in 2004

• Toggle Mechanism• 3-pole and 4-pole• Toggle Mechanism• 3-pole and 4-pole

• Released in 2004• 2-pole and 3-pole

• Released in 2004

• Released in March 2006• 240 Vac 480Y/277• UL1077• Ratings (A): 0.5–63• MCB• 120 / 240 Vac UL• 440 Vac IEC• 60 Vdc 1-pole• 125 Vdc 2-pole

Notes

2

Powerpact(Powerpact P)

P-frame PG, PJ, PL, PK 1200MCCB

— X(dual rated)

MA<800A, MH>800A, all M-frame MGard, all M-frame, ME, MX, NA>800NC, NX, NH, NE-unit mount, CK-fixe

CKAEF_CKHCompact NS630b–

NS1600NS630b–NS1600

— — 1600MCCB

C1251

Powerpact(Powerpact P)

P-frame PG, PJ, PL, PK 1200MCCB

— X(dual rated)

CK-drawout

Compact NS630b–NS1600

NS630b–NS1600

— — 1600MCCB

C1251-drawout

Powerpact(Powerpact P)

P-frame PG, PJ, PL, PK 1200MCCB

— X(dual rated)

CK, ME, MX-with operator

Compact NS630b–NS1600

NS630b–NS1600

— — 1600MCCB

C1251-with motor operator

Powerpact(Powerpact M)

M-frame MG, MJ 800MCCB

— X(dual rated)

MA ≤ 800A MH ≤ 800A NA ≤ 800ACK ≤ 800A

Powerpact(Powerpact R)

R-frame RG, RJ, RL, RK 3000MCCB

— X(dual rated)

PA, PC, PH, PE, PX, CM, NE

Compact NS1600b–NS3200

NS1600b–NS3200

— — 3200MCCB

CM

Powerpact(Powerpact H)

H-frame HD, HG, HJ, HL 150MCCB

— X(dual rated)

Compact NSF 150A,FC,

KA (70–150A),KH (70–150A), KC (70–150A)

Powerpact(Powerpact J)

J-frame JD, JG, JJ, JL 250MCCB

— X(dual rated)

Compact NSF 250A,KA (150–250A),KH (150–250A), KC (150–250A)

Multi-9 — C60 0.5–35MCB

— X(dual rated)

Multi-9 — C60 — — X(dual rated)

Multi-9 — C120 20–100MCB

— X(dual rated)

NC100

CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)

NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.

Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces

Customer UL(489)

ANSI(UL1066)

C37

IEC(60947-2)

Tradename Frame Catalog Reference

P-frameNS630b–NS1600

M-frame

R-frameNS1600b–NS3200

H-frame, J-frame

Multi-9

Page 3: Circuit Breaker Identification Matrix

July 2006

0100DB0602

• Released in 2002

• Released in April 2004

• Released in 2000

• Fixed (SEF)• Drawout (SED)• 3-pole

n to • 3-pole• Rotary mechanism and motor operator

(not available in Powerpact R-frame)

e

2)

• Toggle mechanism• 3-pole

Notes

3

Powerpact Q-frame QB, QD, QC, QJ 250 — X(dual rated)

Q2, QE, KD, KG

Vigirex ground-fault relay

RH10, RH21, RH99

30mA–30A — X(dual rated)

IEC Vigirex, GA, GAT

GC-200 ground-fault relay

GC-200AGC-200BGC-200CGC-200DGC-200E

30mA–1200A — — GC-100

— SE SEF (fixed)SED (drawout)

4000ICCB

— — SEF and SED will transition to theMasterpact NT/NW (2001)

— P-frame PA, PH, PC, PX, PE

2500MCCB

— X(dual rated)

PA, PH, PC, PX and PE will transitiothe R-frame (2002)

— N-frame NA, NC, NX, NE 1200MCCB

— X(dual rated)

NA, NC, and NX will transition to thP-frame (2002)

NE will transition to the R-frame (200

CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)

NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.

Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces

Customer UL(489)

ANSI(UL1066)

C37

IEC(60947-2)

Tradename Frame Catalog Reference

Q-frame

Vigirex

GC-200

SE

PE

NE, NX

Page 4: Circuit Breaker Identification Matrix

July 2006

0100DB0602

• Toggle mechanism• 3-pole• Motor operator

(not available in Powerpact M-frame)• 800 amp I-line• 800 amp unit mount

• Toggle mechanism• 3-pole

• Toggle Mechanism• Motor operator• 3-pole

the

the

he

• Toggle mechanism• Motor Operator• 3-pole

Notes

4

— M-frame MA, MH, MX, ME

1200MCCB

— X(dual rated)

MA and MH will transition to the M-frame (2004)

MX and ME will transition to the P-frame (2002)

L-frame LC, LX, LE, LI, LXI

600MCCB

— X(dual rated)

— L-frame Q4, LA, LH 400MCCB

— X(dual rated)

— K-frame KA, KH, KC, KI 250MCCB

— X(dual rated)

KA (250A 42/25/22) will transition to J-frame (150–250A) (2004)

KH (250A 65/35/25) will transition to J-frame (150–250A) (2004)

KC (250A 100/65) will transition to tJ-frame (150–250A) (2004)

CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)

NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.

Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces

Customer UL(489)

ANSI(UL1066)

C37

IEC(60947-2)

Tradename Frame Catalog Reference

ME, MX

LE, LX

Q4, LA

KA

Page 5: Circuit Breaker Identification Matrix

July 2006

0100DB0602

e

e

• Toggle mechanism• Motor operator• 1-, 2-, 3-pole

• Toggle mechanism• 1-, 2-, 3-pole• Lighting circuit breaker, used in NF panel

boards

• Intended as a branch circuit breaker• 2-pole using a 4-pole space• Released in January 2003

Notes

5

— F-frame FA, FH, FC, FI, FY

100MCCB

— X(dual rated)

FC (100A 100/65) will transition tothe H-frame (2004)

FA (100A 25/18/14) and the H-fram(15–150A) are alternates

FH (100A 65/25/18) and the H-fram(15–150A) are alternates

— E-frame EDB, EGB, EJB 125MCCB

— — Replaces EH(B)(100A 65/14)

— QO QO, QO-H, QO-VH, QH, QOT,

QO-GFI, QOVH-GFI,

QO-AFI, QOVH-AFI

125MCB

— — —

— QO-high Amp QO, QOVH 150–200MCB

— — —

CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)

NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.

Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces

Customer UL(489)

ANSI(UL1066)

C37

IEC(60947-2)

Tradename Frame Catalog Reference

1-pole, 2-pole, 3-pole FA

1-pole, 2-pole, 3-pole EDB

QO, QOGFI, QOAFI

QO-high Amp

Page 6: Circuit Breaker Identification Matrix

July 2006

0100DB0602

• Intended as a branch circuit breaker• 2-pole using a 4-pole space

Notes

6

— Homeline High Amp

HOM BB 150–200MCB

— — —

— HOM HOM, HOMT, HOM-AFI, HOM-GFI, HOM-EPD

15–200MCB

— — —

CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)

NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.

Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces

Customer UL(489)

ANSI(UL1066)

C37

IEC(60947-2)

Tradename Frame Catalog Reference

Homeline High Amp

HOM 1-pole, HOM 2-pole, HOMT 1-pole, HOMT 2-pole,

HOM AFI