Circuit Breaker Identification Matrix
-
Upload
dabsorangejuice -
Category
Documents
-
view
76 -
download
3
Transcript of Circuit Breaker Identification Matrix
July 2006
0100DB0602
Notes
• Fixed/Drawout• 3-pole and 4-pole
• Fixed/Drawout• 3-pole and 4-pole
• Same as Compact NSF• 3-pole and 4-pole• Same as Powerpact C-frame• 3-pole and 4-pole
• Same as Compact NSJ• 3-pole and 4-pole
• Same as Powerpact D-frame• 3-pole and 4-pole
• 3-pole
• 3-pole
1
CIRCUIT BREAKER IDENTIFICATION MATRIX
NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.
Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces
Customer UL(489)
ANSI(UL1066)
C37
IEC(60947-2)
Tradename Frame Catalog Reference
Masterpact NT NT 1200ICCB
800LV PCB
1600Air CB/PCB
M, MP, MC (Masterpact),SE<800A, 800–1200A, DS206_H
Masterpact NW NW 6000ICCB
5000LV PCB
6300Air CB/PCB
M, MP, MC (Masterpact),SE>1200A, all SEH,
DS (except DS206_H)
Powerpact(Powerpact C)
C-frame CG, CJ 250MCCB
— X(dual rated)
—
Compact NSF NFN, NFH,(Square D brand
labeled)
250MCCB
— X(dual rated)
Compact NSF will transition to theH- and J-frame (15–250A)
Powerpact(Powerpact D)
D-frame DG, DJ, DL(Square D brand
labeled)
600MCCB
— X(dual rated)
—
Compact NSJ NJN, NJH, NJL X(dual rated)
— 630MCCB
—
Powerpact GJL GJL(Square D brand
labeled)
100MCCB
— X(dual rated)
—
Compact NSE NEN, NEH 100MCCB
— X(dual rated)
—
Masterpact NT
Masterpact NW
C-frameNSF
D-frameNSJ
GJLNSE
July 2006
0100DB0602
ag A, d,
• Toggle Mechanism• 3-pole and 4-pole
• Toggle Mechanism• 3-pole and 4-pole• Drawout P-frame with toggle mechanism• 3-pole and 4-pole• Drawout P-frame with toggle mechanism
or with motor operator• 3-pole and 4-pole• P-frame with motor operator• 3-pole and 4-pole• P-frame with motor operator• 3-pole and 4-pole• Toggle Mechanism• 3-pole• Released in 2004
• Toggle Mechanism• 3-pole and 4-pole• Toggle Mechanism• 3-pole and 4-pole
• Released in 2004• 2-pole and 3-pole
• Released in 2004
• Released in March 2006• 240 Vac 480Y/277• UL1077• Ratings (A): 0.5–63• MCB• 120 / 240 Vac UL• 440 Vac IEC• 60 Vdc 1-pole• 125 Vdc 2-pole
Notes
2
Powerpact(Powerpact P)
P-frame PG, PJ, PL, PK 1200MCCB
— X(dual rated)
MA<800A, MH>800A, all M-frame MGard, all M-frame, ME, MX, NA>800NC, NX, NH, NE-unit mount, CK-fixe
CKAEF_CKHCompact NS630b–
NS1600NS630b–NS1600
— — 1600MCCB
C1251
Powerpact(Powerpact P)
P-frame PG, PJ, PL, PK 1200MCCB
— X(dual rated)
CK-drawout
Compact NS630b–NS1600
NS630b–NS1600
— — 1600MCCB
C1251-drawout
Powerpact(Powerpact P)
P-frame PG, PJ, PL, PK 1200MCCB
— X(dual rated)
CK, ME, MX-with operator
Compact NS630b–NS1600
NS630b–NS1600
— — 1600MCCB
C1251-with motor operator
Powerpact(Powerpact M)
M-frame MG, MJ 800MCCB
— X(dual rated)
MA ≤ 800A MH ≤ 800A NA ≤ 800ACK ≤ 800A
Powerpact(Powerpact R)
R-frame RG, RJ, RL, RK 3000MCCB
— X(dual rated)
PA, PC, PH, PE, PX, CM, NE
Compact NS1600b–NS3200
NS1600b–NS3200
— — 3200MCCB
CM
Powerpact(Powerpact H)
H-frame HD, HG, HJ, HL 150MCCB
— X(dual rated)
Compact NSF 150A,FC,
KA (70–150A),KH (70–150A), KC (70–150A)
Powerpact(Powerpact J)
J-frame JD, JG, JJ, JL 250MCCB
— X(dual rated)
Compact NSF 250A,KA (150–250A),KH (150–250A), KC (150–250A)
Multi-9 — C60 0.5–35MCB
— X(dual rated)
—
Multi-9 — C60 — — X(dual rated)
—
Multi-9 — C120 20–100MCB
— X(dual rated)
NC100
CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)
NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.
Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces
Customer UL(489)
ANSI(UL1066)
C37
IEC(60947-2)
Tradename Frame Catalog Reference
P-frameNS630b–NS1600
M-frame
R-frameNS1600b–NS3200
H-frame, J-frame
Multi-9
July 2006
0100DB0602
• Released in 2002
• Released in April 2004
• Released in 2000
• Fixed (SEF)• Drawout (SED)• 3-pole
n to • 3-pole• Rotary mechanism and motor operator
(not available in Powerpact R-frame)
e
2)
• Toggle mechanism• 3-pole
Notes
3
Powerpact Q-frame QB, QD, QC, QJ 250 — X(dual rated)
Q2, QE, KD, KG
Vigirex ground-fault relay
RH10, RH21, RH99
30mA–30A — X(dual rated)
IEC Vigirex, GA, GAT
GC-200 ground-fault relay
GC-200AGC-200BGC-200CGC-200DGC-200E
30mA–1200A — — GC-100
— SE SEF (fixed)SED (drawout)
4000ICCB
— — SEF and SED will transition to theMasterpact NT/NW (2001)
— P-frame PA, PH, PC, PX, PE
2500MCCB
— X(dual rated)
PA, PH, PC, PX and PE will transitiothe R-frame (2002)
— N-frame NA, NC, NX, NE 1200MCCB
— X(dual rated)
NA, NC, and NX will transition to thP-frame (2002)
NE will transition to the R-frame (200
CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)
NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.
Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces
Customer UL(489)
ANSI(UL1066)
C37
IEC(60947-2)
Tradename Frame Catalog Reference
Q-frame
Vigirex
GC-200
SE
PE
NE, NX
July 2006
0100DB0602
• Toggle mechanism• 3-pole• Motor operator
(not available in Powerpact M-frame)• 800 amp I-line• 800 amp unit mount
• Toggle mechanism• 3-pole
• Toggle Mechanism• Motor operator• 3-pole
the
the
he
• Toggle mechanism• Motor Operator• 3-pole
Notes
4
— M-frame MA, MH, MX, ME
1200MCCB
— X(dual rated)
MA and MH will transition to the M-frame (2004)
MX and ME will transition to the P-frame (2002)
L-frame LC, LX, LE, LI, LXI
600MCCB
— X(dual rated)
—
— L-frame Q4, LA, LH 400MCCB
— X(dual rated)
—
— K-frame KA, KH, KC, KI 250MCCB
— X(dual rated)
KA (250A 42/25/22) will transition to J-frame (150–250A) (2004)
KH (250A 65/35/25) will transition to J-frame (150–250A) (2004)
KC (250A 100/65) will transition to tJ-frame (150–250A) (2004)
CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)
NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.
Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces
Customer UL(489)
ANSI(UL1066)
C37
IEC(60947-2)
Tradename Frame Catalog Reference
ME, MX
LE, LX
Q4, LA
KA
July 2006
0100DB0602
e
e
• Toggle mechanism• Motor operator• 1-, 2-, 3-pole
• Toggle mechanism• 1-, 2-, 3-pole• Lighting circuit breaker, used in NF panel
boards
—
• Intended as a branch circuit breaker• 2-pole using a 4-pole space• Released in January 2003
Notes
5
— F-frame FA, FH, FC, FI, FY
100MCCB
— X(dual rated)
FC (100A 100/65) will transition tothe H-frame (2004)
FA (100A 25/18/14) and the H-fram(15–150A) are alternates
FH (100A 65/25/18) and the H-fram(15–150A) are alternates
— E-frame EDB, EGB, EJB 125MCCB
— — Replaces EH(B)(100A 65/14)
— QO QO, QO-H, QO-VH, QH, QOT,
QO-GFI, QOVH-GFI,
QO-AFI, QOVH-AFI
125MCB
— — —
— QO-high Amp QO, QOVH 150–200MCB
— — —
CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)
NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.
Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces
Customer UL(489)
ANSI(UL1066)
C37
IEC(60947-2)
Tradename Frame Catalog Reference
1-pole, 2-pole, 3-pole FA
1-pole, 2-pole, 3-pole EDB
QO, QOGFI, QOAFI
QO-high Amp
July 2006
0100DB0602
• Intended as a branch circuit breaker• 2-pole using a 4-pole space
—
Notes
6
— Homeline High Amp
HOM BB 150–200MCB
— — —
— HOM HOM, HOMT, HOM-AFI, HOM-GFI, HOM-EPD
15–200MCB
— — —
CIRCUIT BREAKER IDENTIFICATION MATRIX (continued)
NOTE: This is an abbreviated summary of our circuit breaker naming convention. Not all possible variations are included.
Circuit Breaker Names Standard, Amp Ratings (Max), Class Replaces
Customer UL(489)
ANSI(UL1066)
C37
IEC(60947-2)
Tradename Frame Catalog Reference
Homeline High Amp
HOM 1-pole, HOM 2-pole, HOMT 1-pole, HOMT 2-pole,
HOM AFI