CHLORINE / BROMINE HIGH CAPACITY COMMERCIAL …...1620 hawkins ave., sanford, nc 27330 • (919)...

2
INSTALLATION This feeder is designed for hard plumbing installation using 1" PVC pipe and includes standard threaded inlet and outlet fittings. It operates by pressure differential which circulates through the feeder. The inlet line, (control valve side of feeder) connects to the plumbing between the pump and filter. The outlet side of the feeder connects to pool return line after the filter and/or heater, pool cleaner, diverter valves or any other piece of equipment (if installed). A corrosion resistant check valve such as Rainbow’s R172288 should be installed between the feeder inlet and outlet and the equipment to help prevent equipment damage. DAMAGE TO THE HEATER OR OTHER EQUIPMENT COULD RESULT FROM A HIGH CONCENTRATION OF SANITIZER BACK FLOWING INTO IT WHEN PUMP IS SHUT OFF. It is recommended that feeder be bolted down. OPERATING INSTRUCTIONS Exercise extreme caution when operating or servicing feeder. NEVER OPEN FEEDER WHEN PUMP IS RUNNING. DO NOT INHALE FUMES, especially in hot weather which can create more gases. Wear protective gear. Follow chemical manufacturer’s instructions for handling the chemical. Before start up of feeder your pool should be properly conditioned and the chlorine residual should be 1.0 to 1.5 ppm (Bromine 2.0 to 4.0 ppm). Consult your local dealer for water conditioning information in your area. Because the sanitizer demand in your pool is dependent on many factors (sunlight, high temperatures, bather load, etc.) your valve setting may have to be changed from time to time to adjust to these conditions.When possible, increase the feed rate a day or two in advance. The recommended start up setting is #1. Use a test kit to deter- mine the sanitizer residual. It is recommended that the sanitizer residual be checked daily for the first 5 days to find the ideal setting. NOTE: Higher numbers dispense more chemical. Small gradual changes are imperative for control. DANGER READ CAREFULLY This feeder is designed to use only CLEAN Trichlor-s-trizinetrione OR CLEAN Bromine tables - slow dissolving type. Never use dirty tablets. UNDER NO CIRCUMSTANCES MIX Trichlor or Bromine with Calcium Hypochlorite, with other forms of concentrated chlorine or with other chemicals. Keep inside of feeder clean of dirt and debris at all times. FIRE AND/OR EXPLOSION MAY RESULT. NEVER use oils or grease to lubricate o-ring. Oil in contact with Trichlor OR Bromine may result in FIRE. Lubricate o-ring with Lifegard Silicone o-ring Lubricant ONLY, available at your dealers. If shock treatments or Algaecides containing chemicals other than sanitizers tablets in feeder must be used, turn off Feeder OR remove tablets until the shock or Algae treatment is complete and all granules have dissolved. Failure to do so may result in granules mixing in feeder causing FIRE AND/OR EXPLOSION. The shock or algae treatment dissolved in water is safe with tablets. If you are not the original owner of this feeder, not sure which chemicals was used, or if dirt and/or debris inside feeder, be SAFE and flush thoroughly with fresh water. CAUTION SHOULD BE USED WHEN REMOVING CAP. DO NOT INHALE FUMES. CALCIUM HYPOCHLORITE IS NOT TO BE USED IN ANY FORM. Use of chemicals other than those recommended by manufacturer may be hazardous. CHLORINE / BROMINE HIGH CAPACITY COMMERCIAL FEEDER Model HC 3315, 3330 & 3340 READ CAREFULLY

Transcript of CHLORINE / BROMINE HIGH CAPACITY COMMERCIAL …...1620 hawkins ave., sanford, nc 27330 • (919)...

INS TALLAT IONThis feeder is designed for hard plumbing installationusing 1" PVC pipe and includes standard threaded inletand outlet fittings. It operates by pressure differentialwhich circulates through the feeder. The inlet line, (controlvalve side of feeder) connects to the plumbing betweenthe pump and filter. The outlet side of the feeder connectsto pool return line after the filter and/or heater, pool cleaner,diverter valves or any other piece of equipment(if installed). A corrosion resistant check valve such asRainbow’s R172288 should be installed between thefeeder inlet and outlet and the equipment to help preventequipment damage. DAMAGE TO THE HEATER OROTHER EQUIPMENT COULD RESULT FROM A HIGHCONCENTRATION OF SANITIZER BACK FLOWINGINTO IT WHEN PUMP IS SHUT OFF. It is recommendedthat feeder be bolted down.

OPE R AT ING INS TR UC T IONSExercise extreme caution when operating or servicing feeder. NEVEROPEN FEEDER WHEN PUMP IS RUNNING. DO NOT INHALE FUMES,especially in hot weather which can create more gases. Wear protectivegear. Follow chemical manufacturer’s instructions for handling thechemical. Before start up of feeder your pool should be properlyconditioned and the chlorine residual should be 1.0 to 1.5 ppm (Bromine2.0 to 4.0 ppm). Consult your local dealer for water conditioninginformation in your area. Because the sanitizer demand in your pool isdependent on many factors (sunlight, high temperatures, bather load, etc.)your valve setting may have to be changed from time to time to adjust tothese conditions. When possible, increase the feed rate a day or two inadvance. The recommended start up setting is #1. Use a test kit to deter-mine the sanitizer residual. It is recommended that the sanitizer residualbe checked daily for the first 5 days to find the ideal setting. NOTE:Higher numbers dispense more chemical. Small gradual changes areimperative for control.

D A N G E RREAD CAREFULLYThis feeder is designed to use only CLEAN Trichlor-s-trizinetrione OR CLEAN Bromine tables - slow dissolving type. Never use dirty tablets. UNDER NO CIRCUMSTANCES MIXTrichlor or Bromine with Calcium Hypochlorite, with other forms of concentrated chlorine or with other chemicals. Keep inside of feeder clean of dirt and debris at all times.FIRE AND/OR EXPLOSION MAY RESULT.NEVER use oils or grease to lubricate o-ring. Oil in contact with Trichlor OR Bromine may result in FIRE. Lubricate o-ring with Lifegard Silicone o-ring Lubricant ONLY, available atyour dealers. If shock treatments or Algaecides containing chemicals other than sanitizers tablets in feeder must be used, turn off Feeder OR remove tablets until the shock or Algaetreatment is complete and all granules have dissolved. Failure to do so may result in granules mixing in feeder causing FIRE AND/OR EXPLOSION. The shock or algae treatmentdissolved in water is safe with tablets. If you are not the original owner of this feeder, not sure which chemicals was used, or if dirt and/or debris inside feeder, be SAFE and flushthoroughly with fresh water. CAUTION SHOULD BE USED WHEN REMOVING CAP. DO NOT INHALE FUMES.CALCIUM HYPOCHLORITE IS NOT TO BE USED IN ANY FORM. Use of chemicals other than those recommended by manufacturer may be hazardous.

CHLORINE / BROMINE HIGH CAPACITY COMMERCIAL FEEDER Model HC 3315, 3330 & 3340

READ CAREFULLY

1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-800010951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 WWW.PENTAIRPOOL.COM

All Pentair trademarks and logos are owned by Pentair, Inc. Pentair Aquatic Systems™ are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.

© 2015 Pentair Aquatic Systems. All rights reserved. This document is subject to change without notice.

P/N 24001 REV E 3/15