Chemical and solvent resistant countertops, casework, fumehood liners, pegboards and shelving for today's modern laboratory environments. ©2001 Buy America Compliant! - 100% American Made Phone: (718) 649-1661 Fax: (718) 649-6859 JHC Lab-Resin phenolic casework, countertops, lab furniture file:///F|/JHC/home.htm [12/27/2001 5:56:44 PM]

Transcript of Chemical and solvent resistant countertops, casework, fumehood

Page 1: Chemical and solvent resistant countertops, casework, fumehood

Chemical and solvent resistant countertops, casework,fumehood liners, pegboards and shelving

for today's modern laboratory environments.

©2001 Buy America Compliant! - 100% American MadePhone: (718) 649-1661Fax: (718) 649-6859

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/home.htm [12/27/2001 5:56:44 PM]

Page 2: Chemical and solvent resistant countertops, casework, fumehood

Company Information

JHC Lab-Resin™ is a manufacturing and distributioncompany offering top quality lab grade phenolic resincountertops and furniture. Our phenolic resin materialsgive you the necessary protection and stability for all ofyour work surface needs, even in harsh chemicalenvironments.

You can choose between standard black or a varietyof colors for your laboratory work surfaces whileretaining the protection you need for a durable worksurface. We manufacture everything from basiclaboratory tops and shelving to chemical resistantfume hood liners to provide you with everything youneed to design or upgrade your lab.

JHC Lab-Resin™ is located in Brooklyn, New York and offers delivery and installationthroughout all 50 states, as well as internationally. Our lab grade phenolic resin givesyou the chemical resistance you need for all of your routine, or not so routine laboratoryneeds.

©2001

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/companyinfo/companyinfo.htm [12/27/2001 5:59:36 PM]

Page 3: Chemical and solvent resistant countertops, casework, fumehood

Customer References

   JHC Lab-Resin has been installed at the following:

Arco ChemicalDupont MerckCornell UniversityColumbia UniversityPall CorporationDow CorningNASANY Blood CenterUnion CarbideArramco - TXAmgen Corp.Dept. of the NavyPfizer Corp.Duracell Corp.Bayer Corp.Incyte PharmaceuticalsExxon CorporationWhitehead InstituteUCLA

Albert Einstein College of MedicineMassachusetts Institute of TechnologyBristol Meyers SquibbState University of New York SystemNational Institutes of HealthBrookhaven National LabsProctor and GambleRockefeller UniversityUS Geological SurveyUS Environmental Protection AgencyExxon Mobile CorporationM.D. Anderson Cancer CenterDept. of Food and AgricultureDana Farber Cancer InstituteUniversity of New HampshireSaudi Arramco - Saudi ArabiaRockfeller UniversityLos Alamedas National LabsCalifornia Institute of Technology

Medical University of South CarolinaProctor and Gamble - Bejing ChinaChildrens Hospital of CincinattiUniversity of California Institute ofTechnologyUS Department of EnergyUniversity of South FloridaAres Serono Pharmaceuticals

Lab-Resin™ is available through an extensive networkof laboratory furniture distributors and manufacturers

Please contact us for a complete listing

Procured contracts for 2001:National Institutes of Health: Buildings 37, 38, 40 - Bethesda, MDTexas Department of Transportation - Austin, TXAmgen Corp. - CA, MABayer Corp. Building 27 - West Haven, CTUniversity of New HampshireJornada Experimental Range Headquarters - NMUniversity of Beijing - Beijing China

©2001

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/customerref/customerref.htm (1 of 2) [12/28/2001 10:40:12 AM]

Page 4: Chemical and solvent resistant countertops, casework, fumehood

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/customerref/customerref.htm (2 of 2) [12/28/2001 10:40:12 AM]

Page 5: Chemical and solvent resistant countertops, casework, fumehood

Casework Specifications

1.00 General1.01 General Conditions

The General Conditions and supplementary General Conditions apply to all work in thisdivision.

.

Warranty: JHC Fabrications Phenolic Casework is warranted for a period of five years.Warranty includes factory-supplied labor and materials should any equipment of ourmanufacture show failure in material or workmanship. The company will be pleased torepair or replace such defective parts. Warranties do not apply in the event of neglect orabuse of the unit or parts involved.

B.

1.02 Scope of Work

Provide all Phenolic Resin Casework and accessory items as specified herein. Refer toplans for specific details and requirements.

.

Include all countertops, backsplashes, filler panels, scribe pieces as necessary for acomplete installation.

B.

See drawings for equipment schedules by section.C.

1.03 Related work specified elsewhere

General millwork and custom cabinetry unless specified or so noted on plans..

Resilient base unless so noted on plans.B.

Blocking within wallsC.

Sinks, plumbing fixtures, electrical and mechanical equipment and its related installation,unless noted on drawings to be provided by casework contractors.

D.

1.04 Submittals

Submit in accordance with the general, supplementary, and special conditions of thespecifications

.

Submit shop drawings for approval-showing materials, dimensions, sink locationsfittings, and other accessories. Show relation of material furnished under this section withconnecting or related work of other suppliers and trades.

B.

Submit samples of colors and hardware cuts as requiredC.

Submit one full size sample of finished base cabinet complete with hardware, doors, anddrawers, without finished top.

D.

Submit one full sized sample of finished wall mounted cabinet complete with hardware,doors, and adjustable shelves.

E.

1.05 Qualifications

Drawings and specifications are based upon casework manufactured by JHC Fabrications.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (1 of 9) [12/28/2001 10:44:24 AM]

Page 6: Chemical and solvent resistant countertops, casework, fumehood

595 Berriman Street Brooklyn, NY 11208

Casework of other recognized institutional manufacturers may be considered for openingof the bids. Casework must conform to design, quality of materials, workmanship andfunction of casework as specified and shown on plans.

B.

Manufacturers requesting approval shall submit cabinets, catalogs, and specificationswith the written request as well as a list detailing those areas in which their productdeviates from this specification. Samples may be retained until completion of the job forverification of compliance with these specifications.

C.

Architect/Owners opinion and decision shall be final in evaluation of manufacturer'sproducts.

D.

2.00 Materials2.01 Phenolic Sheets

Phenolic sheets in thickness as specified and in accordance with the test results as shownbelow.

.

Technical Data for JHC Fabrications Phenolic Resin Casework.

Solid Phenolic Performance Properties as per NEMA Standards:

Coefficient of Linear Expansion ASTM D696 1.65x105 in/°C

Comprehensive Strength ASTM D695 4.390x104 psi

Fire Resistance ASTM D635 Self Extinguishing

Flexural Strength(Ultimate)(Modulus)

ASTM D7902.30x104 psi1.50x104 psi

Impact Strength ASTM D256 0.68 ft-lbs in

Tensile Strength(Ultimate)(Modulus)

ASTM D6382.20x104 psi1.70x104 psi

Rockwell Hardness ASTM D785 120

Water Absorption ASTM D570 0.30%

Direct Flame Resistance Bunsen Burner 3 minutes

B.

JHC Phenolic Resin Casework Chemical Resistance Test Procedure

The sample panel was placed on a flat surface, cleaned with soap and water andblotted dry. The panel was then conditioned for 48 hours at 73° F+/- 3°F and50%+/- 5%relative humidity. The Phenolic resin sample was then tested forchemical resistance using 48 different chemical reagents by the followingmethods:

Volatile Chemicals were tested by placing a cotton ball saturated with thereagent in the mouth of a one-ounce bottle and inverting the bottle on the

.

1.

C.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (2 of 9) [12/28/2001 10:44:24 AM]

Page 7: Chemical and solvent resistant countertops, casework, fumehood

surface panel.

Non-volatile Chemicals were tested by placing five (5) drops of the reagenton the surface of the panel and covering with a 25mm watch glass.

b.

For both of the above methods, the reagents were left on the panel for a period of24 hours. The panel was then washed off with water, cleaned with detergent andnaptha, and rinsed with deionized water. The panel was then dried with a toweland evaluated after 24 hours at 73° F+/- 3°F and 50%+/- 5%relative humidityusing the following rating system:

No Effect - No detectable changes in working surface material.

Excellent - Slight detectable change in color or gloss, but no change orsignificant impairment of working surface function or life.

b.

Good - A clearly discernable change in color or gloss, but no change orsignificant impairment of working surface function or life.

c.

Fair - Objectionable change in appearance due to surface discoloration oretch, possibly resulting in deterioration in function over a period of time.

d.

Failure - Pitting, cratering or erosion of working surface material. Obviousand significant deterioration.

e.

2.

JHC Phenolic Resin casework Chemical Resistance:

Chemical Reagent Black White & Colors

Acetate, Amyl No Effect No Effect

Acetate, Ethyl No Effect No Effect

Acetic Acid 98% No Effect No Effect

Acetone No Effect No Effect

Acid Dichromate, 5% No Effect No Effect

Alcohol, Butyl No Effect No Effect

Alcohol, Ethyl No Effect No Effect

Alcohol, Methyl No Effect No Effect

Ammonium Hydroxide, 28% No Effect No Effect

Benzene No Effect No Effect

Carbon Tetrachloride No Effect No Effect

Chloroform No Effect No Effect

Chromic Acid, 60% No Effect Excellent

Cresol No Effect No Effect

Dichlor Acetic Acid No Effect No Effect

Dimethylformanide No Effect No Effect

Dixane No Effect No Effect

Ethyl Ether No Effect No Effect

D.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (3 of 9) [12/28/2001 10:44:24 AM]

Page 8: Chemical and solvent resistant countertops, casework, fumehood

Formaldehyde, 37% No Effect No Effect

Formic Acid, 90% No Effect Excellent

Furfural No Effect No Effect

Gasoline No Effect No Effect

Hydrochloric Acid, 37% No Effect No Effect

Hydroflouric Acid, 48% No Effect Excellent

Hydrogen Peroxide, 3% No Effect No Effect

Iodine Tincture of No Effect No Effect

Methyl Ethyl Ketone No Effect No Effect

Methylene Chloride No Effect No Effect

Mono Chlorobenzene No Effect No Effect

Naphthalene No Effect No Effect

Nitric Acid, 20% No Effect Good

Nitric Acid, 30% No Effect Good

Phenol, 90% No Effect No Effect

Phosphoric Acid, 85% No Effect No Effect

Silver Nitrate Saturated No Effect No Effect

Sodium Hydroxide, 10% No Effect No Effect

Sodium Hydroxide, 20% Failure No Effect

Sodium Hydroxide, 40% Failure Excellent

Sulfuric Acid 33% No Effect Excellent

2.02 Hardware

Hinges to be heavy duty, five-knuckle institutional-tip, fixed pin feature with all edgeseased. Hinge to be full wrap-around type of tempered steel .095" thick. Each hinge tohave a minimum of nine screw attachment holes. Hinges to accommodate door thicknessof ½". Hinge to be black epoxy powder finish.

.

Hinges: one pair per door to 48" height. One and one-half pair over 48" in height. Hingeto allow 270 degrees of swing.

B.

Pulls to be selected from, but not limited to the following options:

Dull chrome 4" projecting type: LH 3191.

Satin chrome 4" wire pull: LH 3212.

Black Nylon 4" wire pull: LH 3253.

C.

Pulls: Drawers under 30" in width to receive one pull. Drawers over 30" in width toreceive two pulls. All doors to receive one pull.

D.

Catches: Steel zinc finish polyethylene roller type heavy duty catch with adjustabletension feature.

E.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (4 of 9) [12/28/2001 10:44:24 AM]

Page 9: Chemical and solvent resistant countertops, casework, fumehood

Drawer slides: As shown below or as specified by Owner/Architect.

Standard Drawers: Self closing epoxy coated steel bottom corner mounted with80% extension. Rollers to be nylon with tempered steel axles. Drawer slides tohave captive profiles to provide stable tracking and positive pullout stop with asecondary lock-out position. Load capacity to be 100 lbs. Standard drawer slides tohave lifetime guarantee.

1.

File Drawers: Self closing epoxy coated steel bottom corner mounted with 100%extension. Drawer slides to have captive profiles to provide stable tracking andpositive stop with a secondary lock-out position. Load capacity to be 150 lbs.

2.

F.

Adjustable shelf supports: Shelves to be supported by plated metal shelf rests which fitinto pre-bored 5mm holes. Shelf rest holes to be bored by automatic computer controlledboring machine.

G.

Sliding door hardware: As shown below or as specified by Owner/Architect:

Phenolic framed glass doors and solid Phenolic doors: to be supported from top ofdoor by extruded aluminum track. Fully adjustable steel carriers with two nylonwheels per carrier to be attached to door, two carrier assemblies to be attached toeach door. Load capacity per door to be 75 lbs. Nylon floor guides to be attachedto cabinet bottom to hold doors captive and insure proper sliding action.

1.

Unframed glass doors: Doors to be ¼ laminated safety glass with all edgespolished. Bottom of door to receive extruded aluminum shoe track assembly,lower edge of glass to fit into the top of this track. The bottom of this same track toreceive metal wheel assembly. One metal wheel assembly to be located every 12".Metal wheel assembly to ride on extruded aluminum track with flange, which is tobe screwed to top of wall cabinet bottom. Top of glass doors to receive snap-onsilencing guide which is guided by extruded aluminum upper track that is screwedto the bottom of wall cabinet top.

2.

H.

Locks: Drawer and hinged door locks to be disc tumbler cam locks in satin chromefinish, keyed alike and master keyed, with removable lock core for changing lockarrangements. Drawer cabinets which have locks that are keyed differently are to receivesecurity panels located between drawers. Phenolic framed glass doors and solid Phenolicsliding doors to have push type pin tumbler lock in satin chrome finish. Unframed glassdoors to have sliding panel lock specifically designed to fit in bottom aluminum shoetrack assembly.

I.

Wardrobe rod: 1-1/16" chrome plate steel rod supported by flanges.J.

Cabinet levelers: 3/8" Stem levelers attached to 4 hole steel mounting brace containing astrengthening rib for added reinforcement.

K.

3.00 Construction3.01 General

All cabinet body component shall be secured utilizing concealed interlocking mechanicalfasteners as approved by AW1400B.S.8-A, AWI1600B-S-4.A, sections 14 and 25 of theWoodwork Institute of California Manual of Millwork, and shall be especially designedfor use in joining flat panels.

.

All joints to be tight fitting and shall not rupture or loosen due to:B.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (5 of 9) [12/28/2001 10:44:24 AM]

Page 10: Chemical and solvent resistant countertops, casework, fumehood

Racking of casework during shipment and installation1.

Normal use2.

Seismic shock as tested and approved by the Woodwork Institute of California forcasework used in schools and hospitals.

3.

All fastening devices and screws shall be treated to deter or resist corrosion. If specifiedby Owner/Architect, all screws shall be stainless steel.

C.

3.02 Construction Features

General conditions: All Cabinets

All end panels, cabinet bottoms, wall and tall cabinet tops, vertical dividers,vertical rails, exposed finished back panels, toe kicks, drawer fronts, drawerbodies, and doors, to be 1/2" phenolic resin as described in section 2.01 of thisspecification.

1.

All base cabinet horizontal rails, adjustable shelves, and wall cabinet hangingcleats to be 3/4" phenolic resin as described in section 2.01 of this specification.

2.

All removable and fixed backs to be 1/8" phenolic resin as described in section2.01 of this specification.

3.

Unless specified by Owner/Architect, all cabinets in wood grain phenolic shallhave the grain running parallel with the length of the component. Grain directionof drawer fronts shall be horizontal. Grain direction of doors shall be vertical.

4.

.

Base Cabinets

Cabinet and panels to be secured to cabinet bottom and to horizontal and verticalrails with a minimum of 10 interlocking mechanical fasteners.

1.

Cabinet base to be integral with cabinet and end panels as a standard feature unlessa separate base unit is specifically called for and indicated on plans. Standardintegral base to have toe kick attached to cabinet end panels by means of steelangles and screws. Cabinet to be vermin proof.

2.

Cabinet end panels to be secured at top of base cabinet by means of 2 - 3/4" x 31/2" horizontal rails and 1 - 1/2" x 7 3/4" upper back panel which also serves aswall attachment cleat. Cabinet end panels to be secured at bottom of base cabinetwith a solid 1/2" thick cabinet bottom and 1/2" thick integral toe kick panel.

3.

Removable cabinet backs to be 1/8" thick white phenolic resin. Backs to beremoved from inside of cabinet without the use of tools or mechanical fasteners.Cabinets with only banks of drawers do not receive removable backs.

4.

Drawer body sides, subfronts, and backs to be 1/2" thick white phenolic resin.Drawer body bottoms to be 1/8" thick white phenolic resin. Attachments of drawerbody sides to drawer body fronts and backs to be a screwed butt joint.

5.

Locked drawers within the same cabinet which are keyed differently to have 1/2"thick phenolic resin security panels attached to cabinet end panels with a minimumof 4 concealed interlocking mechanical fasteners.

6.

All interior cabinet components to be white.7.

Base cabinet toe kicks to be black.8.

B.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (6 of 9) [12/28/2001 10:44:24 AM]

Page 11: Chemical and solvent resistant countertops, casework, fumehood

All cabinets to have independently adjustable 3/8" stern levelers accessible frominside of cabinet. Levelers to be attached to cabinet end panels by means of a steel4 hole mounting brace containing a strengthening rib for added reinforcement.Leveler access holes to be covered with white plastic caps.

9.

Color of exposed end panels to match color selection of drawer fronts, doors, kneespace panels, and fillers. Colors of unexposed end panels to be off-white.Construction fasteners used for attachment of cabinet end panels to vertical cabinetmembers to be concealed. Visible construction fasteners or hole covers shall not beacceptable.

10.

All base fillers to be 1/2" phenolic resin.11.

Wall Cabinets

Cabinet end panels to be secured to cabinet top and bottom with a minimum of 8interlocking mechanical fasteners.

1.

Cabinet end panels to be rabbeted to receive cabinet back and hanging cleat.2.

Cabinet back to be 1/8" phenolic resin attached to cabinet top, and bottom withscrews.

3.

Hanging cleat to be 1/4" thick phenolic resin attached to cabinet end panels, top,and bottom with screws. Bottom edge of top cleat to be cut on an angle. Matchingangle to be cut on hanging cleat attached to the wall.

4.

All interior components to be white.5.

All exposed end panels to match color of doors and cabinet bottom. Color ofunexposed end panels to be off white. Color of cabinet bottom to match all otherexposed surfaces. Construction fasteners used for attachment of cabinet end panelsto vertical cabinet members to be concealed. Visible construction fasteners or holecovers shall not be acceptable.

6.

All wall fillers to be 1/2" phenolic resin.7.

C.

Tall Cabinets

Cabinet end panels to be secured to cabinet top, fixed shelf, wall attachment cleat,and bottom with a minimum of 14 interlocking mechanical fasteners.

1.

Cabinet base to be integral with cabinet end panel as a standard feature unless aseparate base unit is specifically called for and indicated on plans. Standardintegral base to have toe kick attached to cabinet end panels by means of steelangles and screws. Cabinet to be vermin proof.

2.

Cabinet end panels to be rabbeted to receive cabinet back.3.

Cabinet back to be 1/8" phenolic resin attached to cabinet top, fixed shelf, wallattachment cleat and bottom with screws.

4.

The following interior cabinet components to be white: cabinet end panels,bottoms, tops, fixed shelves, back, wall attachment cleats, and inside of doors.

5.

D.

4.00 Countertops4.01 Phenolic Resin

1" thick phenolic resin countertops as shown on drawings and as described in section.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (7 of 9) [12/28/2001 10:44:24 AM]

Page 12: Chemical and solvent resistant countertops, casework, fumehood

2.01 of this specification.

4.02 Stainless Steel

Stainless Steel, Type 304, non-magnetic, 18-8, Galvanized, cold rolled steel, 16 gaugethroughout. Shall be fabricated in one piece, where practicable, with welded corners,channel shaped exposed edges and reinforced with three (3) full length hat shapedgalvanized channels. Sink bowls, where required, shall be fabricated with horizontal andvertical corners covered to a 1" (2.54) radius, corners made spherical without fillers orsolder, and welded to top. Back and/or end splashes shall be integral with top andcovered at point of turn up to a 1/2" (1.27) radius. Exposed edges of sink tops shall beprovided with integral inverted "V" nosing. After fabrication, a moisture proof, sounddeadening, mastic shall be applied to the underside of the top and outside of sink bowls.All welding shall be accomplished by heli-arc method with all exposed welds groundsmooth. All exposed surfaces shall be free of pit marks, weld seams and scale, andpolished to a stain finish.

.

5.00 Execution5.01 Shipping

All casework shall be blanket wrapped and delivered to jobsite in furniture vans..

5.02 Casework Installation

Casework shall not be delivered to jobsite until building has become adequately dry andsecure. Installation shall be by Casework Manufacturer's authorized representative.

.

Casework is to be installed plumb and true, and is to be securely anchored in place.Scribe casework fillers as necessary for a tight fit.

B.

Wall cabinets shall be securely fastened to horizontal blocking, not to plaster, lath, orwallboard. Reinforcement of stud walls shall be provided by appropriate trade duringerection of walls. Casework Manufacturer shall accurately locate blocking requirementson shop drawings.

C.

Install countertops on base cabinets using screws.D.

5.03 Cleaning and Protection

Empty drawers of dust and dirt. Wipe out cabinet interiors to remove dust and dirt.Remove pencil ad other marks from cabinets and countertops. Remove all packaging,scraps, and debris resulting from installation activities.

.

Make final adjustment to doors and drawers. Doors shall swing freely, catches shall holdsecurely, and all doors shall be aligned both vertically and horizontally. Drawers shallopen and close smoothly, without binding and without excessive slide play.

B.

Keys shall be appropriately labeled and turned over to the Owner.C.

JHC Fabrications, Inc. reserves the right to change this specification without notice orobligation to incorporate improved materials, hardware, or manufacturing techniques.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (8 of 9) [12/28/2001 10:44:24 AM]

Page 13: Chemical and solvent resistant countertops, casework, fumehood

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/cabinetspecs2.htm (9 of 9) [12/28/2001 10:44:24 AM]

Page 14: Chemical and solvent resistant countertops, casework, fumehood

Phenolic Casework

Phenolic casework is made from solid phenolicpanels which have been thermofused under heatand pressure to form a solid black chemicalresistant phenolic core. Phenolic resin caseworkshould be used wherever superior chemical orcorrosion resistance is required. Lab-Resin™Phenolic Casework is designed for use ascabinets, lockers, countertops, shelving,pegboards, and reagent racks.

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/phenolic/phenolic.htm (1 of 2) [12/28/2001 10:40:53 AM]

Page 15: Chemical and solvent resistant countertops, casework, fumehood

Chemical and corrosion resistantphenolic resin cabinet. Constructedwith concealed fasteners.

1.

Reinforced cabinet bottom preventsdeflection under maximum loads.Bottom of cabinet is recessed foroptional under cabinet lighting.

2.

Sliding doors mounted on upper trackfor more efficient operation.

3.

Front edge of shelf supported toprevent deflection.

4.

Durable black nylon pulls.5.

Chemical and corrosion resistantphenolic resin cabinet. Constructedwith concealed fasteners.

1.

Drawer body made with 1/2" thickblack chemical and corrosion resistantphenolic resin.

2.

Self-closing epoxy coated drawerslides.

3.

Removable back panel for convenientaccess to service chase.

4.

270° heavy duty five knuckleinstitutional hinge with baked on blackepoxy finish.

5.

Durable black nylon wire pulls.6.

©2001

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/phenolic/phenolic.htm (2 of 2) [12/28/2001 10:40:53 AM]

Page 16: Chemical and solvent resistant countertops, casework, fumehood

Product Information

JHC Lab-Resin™ is a solid, modified, phenolicresin composite, thermo-fused under heat andpressure to form a solid, black, chemical-resistantcomposition throughout the entire thickness of thepanel.

JHC Lab-Resin™ is designed for use ascountertops, casework, shelving, pegboards, andreagent racks. It should be used wherever superiorchemical, abrasion or stain resistance is required.An additional benefit of JHC Lab-Resin™ is that itwill not support bacteria or fungus.

JHC Lab-Resin™ is:Extremely chemical and solvent resistant●

Corrosion and stain resistant●

Impact resistant●

Available in sheet sizes up to 12 feet x 5feet

Non-asbestos●

Finished two sides●

UV stable●

Easily modified using carbide tipped tools●

Solid phenolic throughout●

Care and Maintenance

JHC Lab-Resin™ products will not stain or etch when exposed to most chemicals orsolvents. Periodic cleaning with liquid detergents will keep JHC Lab-Resin™ countertops looking good. All spills must be cleaned up as soon as possible. The use of steelwool and any abrasive cleaners should be avoided.

©2001

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/productinfo/productinfo.htm (1 of 2) [12/28/2001 10:41:25 AM]

Page 17: Chemical and solvent resistant countertops, casework, fumehood

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/productinfo/productinfo.htm (2 of 2) [12/28/2001 10:41:25 AM]

Page 18: Chemical and solvent resistant countertops, casework, fumehood

Product Options

Solid Phenolic Pegboards:Our Lab-resin pegboards set an industry standard for quality andcraftsmanship. Each pegboard is precision drilled to accept ourunique 5" long, two prong, polypropylene pegs. Pegs protrude at45 degrees to assure quick drying of glassware. Pegboards havea finished back and can be mounted on a wall column, pipechase, open unistrut or umbilical.

Self Supporting Pegboards:Self supporting pegboards can be used on any flat surface suchas demo tables, countertops, or a reagent shelf. Each pegboard issupplied with two solid phenolic resin fixed supports sloping at45 degrees.

Finish Options:

Non-Glare Matt (NGM)Low gloss smooth finish. Suggestedapplications; chemical work areas, writingareas, wall and reagent shelving andpegboards.

Textured Surface Finish (TSF)Medium gloss fine pebble grained finish.Suggested applications are areas prone tochemical and mechanical abuse. TSF finishprovides optimum abrasion resistance.

Colors:A colletion of 25 standard colors andpatterns are available. All colored lab resinhas a black core. Samples of actual materialsor a color card is available upon request.Please consult with JHC Fabrications forcustom colors.

Click Here for Color Samples

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/productoptions/productoptions.htm (1 of 2) [12/28/2001 10:42:01 AM]

Page 19: Chemical and solvent resistant countertops, casework, fumehood

Architectural Specification:

JHC Lab-Resin™ products are specified inLaboratory Casework Sections 11600 and12345 of most equipment specifications.

JHC Lab-Resin™ work surfaces provide ahomogeneous blend of modified phenolicresins fused together under high pressure andheat in specially designed thermoset pressmolds to form a solid black chemical resistantcomposite throughout the entire thickness.Work surface shall be good two sides, with aremovable plastic peel coat to protect worksurface from other trades during construction.

Drying racks (Pegboards) shall be of the samematerial as the work surface.

Back Splashes: All back splashes shall be ofthe same material, thickness and finish aswork surface. Back splashes are to be suppliedloose for field application

Wall Shelving, Reagent Shelving and relatedUprights: Lab-Resin Solid Phenolic shall befinished two sides at time of thermosettingentire panel. No other means of finishing willbe acceptable.

Acceptable Thickness Tolerance: +/- 0625●

Tests:

Maximum Uniform Self Load (lbs.) - 1/4 Deflection at Center Shelf

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/specifications.htm (1 of 3) [12/28/2001 10:43:23 AM]

Page 20: Chemical and solvent resistant countertops, casework, fumehood

(A) ShelfSize(B)Thickness

12x24 12x36 12x48 24x36

1/4" 40 15 7 253/8" 172 52 24 1101/2" 371 110 50 2253/4" 1400 401 172 8151" 2605 785 335 1500

Shelf sizes and thickness arerepresented in inches.

Deflection Tests conducted withshelves supported at both ends.

All of the information, suggestions, andrecommendations to the properties and usesof the JHC Lab-Resin product describedherein are based upon tests and data believedto be accurate. However, the finaldetermination regarding the stability of anymaterial described herein for the usecontemplated, the manner of such use, andwhether the use infringes any patents is thesole responsibility of the user. There is nowarranty express or implied, including,without limitation, warranty ofmerchantability or fitness for a particularpurpose. Under no circumstances shall we beliable for the incidental or consequential lossor damage.

Technical Data SheetPerformance Properties as per NEMA Standards

Coefficient of linerexpansionCompressive StrengthFire ResistanceFlexural Strength       Ultimate       ModulusImpact StrengthTensile Strength       Ultimate       ModulusRockwell HardnessWater AbsorptionDirect Flame Resistance

TestASTM D696ASTM D695ASTM D635ASTM D790

ASTM D256ASTM D638

ASTM D785ASTM D570

Bunsen Burner

Result1.65 x 105 in/degC

43,000 PSISelf Extinguishing

23,000 PSI15,000 PSI

.68 ft-lbs inch

22,000 PSI17,000 PSI

1200.30%

3 minute

Cabinet Specifications Chemical Resistance

©2001

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/specifications.htm (2 of 3) [12/28/2001 10:43:23 AM]

Page 21: Chemical and solvent resistant countertops, casework, fumehood

©2001

Configurations:Black twosides

Color twosides

NGM twosides

TSF twosides

Differentcoloreachside

Available SheetSizes:

96 inches x 48inches

96 inches x 60inches

120 inches x 60inches

144 inches x 60inches

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/productoptions/productoptions.htm (2 of 2) [12/28/2001 10:42:01 AM]

Page 22: Chemical and solvent resistant countertops, casework, fumehood

Tests

Protectability Grading

NO EFFECTNo detectable change inworking surface material.

EXCELLENTSlight detectable changein color or gloss.

GOODA clearly discernablechange in color orworking surface.

FAIRObjectionable change inappearance due to etch.

FAILUREPitting, cratering orerosion of workingsurface.

Acetate, AmylAcetate, EthylAcetic Acid 98%AcetoneAcid Dichromate, 5%Alcohol, ButylAlcohol, EthylAlcohol, MethylAmmonium HydroxideBenzeneCarbon TetrachlorideChloroformChromic Acid, 60%CresolDichlor Acetic AcidDimethylformanide

Black

No EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo Effect

Colors

No EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo Effect

FormaldehydeFurfuralHydroflouric Acid, 48%Hydrogen PeroxideIodine Tincture ofMethyl Ethyl KetoneMethylene ChlorideMono ChlorobenzeneNaphthaleneNitric Acid, 30%Phenol, 90%Phosphoric Acid, 85%Silver Nitrate SaturatedSodium Hydroxide 10%Sodium Hydroxide 20%Sodium Hydroxide 40%Sulfuric Acid 33%

Black

No EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectFailureFailureNo Effect

Colors

No EffectNo EffectExcellentNo EffectNo EffectNo EffectNo EffectNo EffectNo EffectGoodNo EffectNo EffectExcellentNo EffectNo EffectExcellentNo Effect

JHC Lab-Resin phenolic casework, countertops, lab furniture

file:///F|/JHC/specifications/testing.htm (1 of 2) [12/28/2001 10:44:55 AM]

Page 23: Chemical and solvent resistant countertops, casework, fumehood

DixaneEthyl Ether

No EffectNo Effect

No EffectNo Effect

Sulfuric & Nitric Acids    mix 77%, 70%Zinc Chloride Saturated

No EffectNo Effect

GoodNo Effect

Test results are compiled in a controlled environment. Users should test counter top samples beingconsidered for any general or specific application.