Change of Use to a Hair Salon 267 Victoria Road, Gladesville

40
Change of Use to a Hair Salon 267 Victoria Road, Gladesville 29.07.2021

Transcript of Change of Use to a Hair Salon 267 Victoria Road, Gladesville

Change of Use to a Hair Salon

267 Victoria Road, Gladesville

29.07.2021

STATEMENT OF ENVIRONMENTAL EFFECTS

© East Coast Property and Planning Australia

ABN 13 626 470 424

All Rights Reserved. No material may be reproduced without prior permission.

ecpp.com.au

STATEMENT OF ENVIRONMENTAL EFFECTS

TABLE OF CONTENTS

1. Introduction................................................................................................................................... 1

2. The Site.......................................................................................................................................... 2

Site Description ............................................................................................................................. 2

Site Context ................................................................................................................................... 3

3. The Proposal .................................................................................................................................. 4

4. Relevant Planning Controls ............................................................................................................ 5

STATE ENVIRONMENTAL PLANNING POLICY NO. 55 – REMEDIATION OF LAND .............................. 5

STATE ENVIRONMENTAL PLANNING POLICY NO. 64 – ADVERTISING AND SIGNAGE ....................... 5

CANTERBURY LOCAL ENVIRONMENTAL PLAN 2012 (LEP 2012) ...................................................... 8

CANTERBURY DEVELOPMENT CONTROL PLAN (DCP) 2012 – PART B (GENERAL CONTROLS) .... Error!

Bookmark not defined.

CANTERBURY DEVELOPMENT CONTROL PLAN (DCP) 2012 – PART D (BUSINESS CENTRES) ...... Error!

Bookmark not defined.

CANTERBURY DEVELOPMENT CONTROL PLAN (DCP) 2012 – PART F (SPECIFIC LAND USES AND

SPECIFIC SITES) ................................................................................. Error! Bookmark not defined.

5. Matters Requiring Further Consideration .......................................... Error! Bookmark not defined.

Parking Provisions ............................................................................. Error! Bookmark not defined.

6. Environmental Planning and Assessment Act 1979 – Matters for Consideration ........................... 35

6. Conclusion ................................................................................................................................... 36

1 STATEMENT OF ENVIRONMENTAL EFFECTS

1. INTRODUCTION

This Statement of Environmental Effects has been prepared for the change of use to a hair salon and use of associated signage in accordance with the Ryde Council Development Application Guide to be assessed under section 4.15 of the Environmental Planning and Assessment Act, 1979. The proposed use is based on all relevant local and state planning instruments. The subject site is located within the B4 Mixed Use zone zone under the provisions of the Ryde Local Environmental Plan 2014 (RLEP 2014). The proposed use and associated signage is permitted within the zone, subject to development consent and there are no major affectations applicable to the subject site. Furthermore, the application has been based on all relevant local planning instruments, state planning instruments and local development controls and guidelines. The Development Application is supported by this Statement of Environmental Effects and is to be assessed in conjunction with the following plans/documentation: • Architectural Plans prepared by Archizone, Project No. 2021_032, Drawing Nos: 000, 001, 002,

003, 004 dated 08.05.21; • Waste Management Plan prepared by Karizma Hair

This Statement describes the site and its context with the surrounding area, together with the relevant planning controls and policies relating to the site and development type. It provides an assessment of relevant planning instruments and controls against the heads of consideration pursuant to Section 4.15 of the Environmental Planning and Assessment Act 1979. The proposed use has considered the predominant character of the development in context with its locality and is considered sympathetic to the amenity enjoyed by adjoining tenancies along Victoria Road. As the assessment of the proposal has not identified any significant environmental or amenity impacts, it is concluded that the development is considered to be acceptable and worthy of the support of City of Ryde Council.

2 STATEMENT OF ENVIRONMENTAL EFFECTS

2. THE SITE

SITE DESCRIPTION

The site is zoned B4 Mixed Use. The premises is located on the ground floor at 267 Victoria Road, Gladesville and is legally described as Lot 1 of DP 608655. The premises is located on the eastern side of Victoria Road and located within a two storey building. The building is located is adjacent to a laneway which access public parking at the rear. Street parking is located along Victoria Road and surrounding streets and loading and waste storage for the tenancy is located at the rear of the site adjacent to the car park.

Figure 1. Aerial (Planning Portal NSW, 2021)

3 STATEMENT OF ENVIRONMENTAL EFFECTS

SITE CONTEXT

The surrounding context is characterised by low to medium scale commercial, retail and mixed use developments along an active street frontage. The site is in proximity to R4 High Density Residential to the north east, R2 Low Density Residential to the East and R3 Medium Density Residential to the south east. The site has a frontage to Victoria Road which is a Classified Road. Victoria Road is zones SP2 Special Purposes. The area is well serviced by public transport with ample street parking available on Victoria Road and surrounding streets.

Figure 2. Zoning Map (Planning Portal NSW, 2021)

3. DEVELOPMENT CONSENT HISTORY AND BACKGROUND

• On 22 June 2020, Private Certifier issued Complying Development Certificate No. 200141-01 for minor internal alterations and refurbishments works to existing commercial building.

• The subject premises was fitted out as a hairdressing salon. As a result of a miscommunication, the proprietor of the hairdresser salon was of the understanding the issued CDC included the hairdresser salon fitout. However, the Principal Certifying Authority confirmed CDC 200141-01 did not include the fitout and as such, a Building Information Certificate for works and Development Application for use was required to regularised the subject works and use.

• On 21 June 2021, Building Information Certificate BC2021/0034 was lodged for fitout of ground floor for purpose of hairdresser salon.

4 STATEMENT OF ENVIRONMENTAL EFFECTS

• On 16 July 2021, Council requested additional information for Building Information Certificate BC2021/0034. In particular, Item 1 requested proof of development consent for use of the ground floor shop as a hairdressing salon.

4. THE PROPOSAL

The proposal seeks development consent for the use of the subject premises as a hairdresser salon and use of associated signage. The fit out which has been undertaken includes the following:

o New partition walls to the eastern side of the lower ground floor for the creation of storerooms and laundry.

o 2 x Awning Facia business identification sign measuring 600mm x 1.8m o LED light box measuring 2.6m x 500mm x 200mm o Furniture and appliances including tables, chairs and reception counter.

The premises will employ a maximum of 6 staff members at one time and the proposed hours of operation are as below: Monday, Tuesday, Thursday, Friday, Saturday – 9am to 5pm Wednesday – (9am to 8pm) Floor plan of the proposed use is as follows:

Figure 3. Proposed Floor Plan

5 STATEMENT OF ENVIRONMENTAL EFFECTS

5. RELEVANT PLANNING CONTROLS

The following planning instruments and controls are relevant to the assessment of this proposal:

• Ryde Local Environmental Plan (RLEP) 2014;

• State Environmental Planning Policy No. 55 – Remediation of Land;

• State Environmental Planning Policy (BASIX) 2004;

• Ryde Development Control Plan (RDCP) 2014; and

• Environmental Planning and Assessment Act 1979 There is no draft Environmental Planning Instrument applicable to this development.

STATE ENVIRONMENTAL PLANNING POLICY NO. 55 – REMEDIATION OF LAND

State Environmental Planning Policy No. 55 – Remediation of Land requires that consent must not be granted to the carrying out of any development on land unless Council has considered whether the land is contaminated or requires remediation for the proposed use. The site is for a restaurant within an existing building that has been previously assessed for contamination. As such, a further assessment under this Policy is not required.

STATE ENVIRONMENTAL PLANNING POLICY NO. 64 – ADVERTISING AND SIGNAGE

This SEPP aims to improve the amenity of urban and natural settings by managing the impact of outdoor advertising. The policy responds to growing concerns from the community, the advertising industry and local government that existing controls and guidelines were not effective. SEPP No. 64 offers the comprehensive provisions and consistent approach needed. In accordance with Part 3, Clause 9, the proposed signage is defined as ‘business identification signs’ and in accordance with the SEPP, consideration of the following design considerations: Character of the Area Is the proposal compatible with the existing or desired future character of the area or locality in which it is proposed to be located? The premise is located within a B4 – Mixed Use zone with many adjoining businesses displaying similar signage and therefore the proposed signage is considered to be compatible with the existing, and desired future character of the locality. Is the proposal consistent with a particular theme for outdoor advertising in the area or locality? Many businesses along Victoria Road display similar signage to what is proposed being awning facias and illuminated under awning signage as well as window signs. The proposed signage is therefore considered to be consistent with the theme of signage within the locality (see Figure 5 below). The proposed signage is unobtrusive and reflects the purpose of the zone.

6 STATEMENT OF ENVIRONMENTAL EFFECTS

Figure 5. Theme of Signage within the Locality (Google Maps, 2021) Special areas Does the proposal detract from the amenity or visual quality of any environmentally sensitive areas, heritage areas, natural or other conservation areas, open space areas, waterways, rural landscapes, or residential areas? The site is not located within the immediate vicinity of the above identified areas. Views and vistas Does the proposal obscure or compromise important views? No important views are obscured by the proposed signage. Does the proposal dominate the skyline and reduce the quality of vistas? The proposed signage is located on or below the awning level and does not dominate the skyline or reduce the quality of vistas. Furthermore, the proposed signage is considered compatible with existing signage for adjoining tenancies along Victoria. Does the proposal respect the viewing rights of other advertisers? The proposed signage respects the viewing rights of other tenancies located along Victoria Road. Streetscape, setting or landscape. Is the scale, proportion, and form of the proposal appropriate for the streetscape, setting or

7 STATEMENT OF ENVIRONMENTAL EFFECTS

landscape? The proposed signage is similar to existing signage within the locality is therefore considered to be appropriate within the Gladesville Victoria Road Local Centre setting. Does the proposal contribute to the visual interest of the streetscape, setting or landscape? The proposed signage is considered compatible with existing signage for tenancies along Victoria Road within the Belmore Local Centre zone. Does the proposal reduce clutter by rationalising and simplifying existing advertising? The signage will act as an appropriate and simple advertising element to the site and is conducive to its total area. Does the proposal protrude above buildings, structures or tree canopies in the area or locality? The proposed signage does not protrude above the building and is located at or below the awning level. Site and building Is the proposal compatible with the scale, proportion and other characteristics of the site or building, or both, on which the proposed signage is to be located? The proposed signage is considered compatible with existing signage for tenancies along Victoria Road within the Gladsesville Victoria Road Mixed Use zone. Does the proposal respect important features of the site or building, or both? The proposed signage is located at or below the awning level and respects the features of the existing building. Does the proposal show innovation and imagination in its relationship to the site or building, or both? The proposed signage relates to the proposed use of the tenancy. Illumination Would illumination result in unacceptable glare? No glare impacts are envisaged as the illumination is within a light box similar to existing under awning signs within the locality. Would illumination affect safety for pedestrians, vehicles, or aircraft? The proposed signage is a light box and is not considered to affect the safety of pedestrians, vehicles, or aircraft. Would illumination detract from the amenity of any residence or other form of accommodation?

8 STATEMENT OF ENVIRONMENTAL EFFECTS

The proposed signage is located along Victoria Road within the Gladesville Local Centre and is not visible from any residence or other form of accommodation. Is the illumination subject to a curfew? Illumination of the signage will be switched off when the premises closes. Safety Would the proposal reduce the safety for any public road? The proposed signage is a light box sign and will not reduce the safety of any public roads. Would the proposal reduce the safety for pedestrians or bicyclists? The proposed signage is located under the awning and will not reduce the safety of pedestrians or bicycles. Would the proposal reduce the safety for pedestrians, particularly children, by obscuring sightlines from public areas? The proposed signage is located under the awning and does not obscure sightlines from public areas. The evaluation of the application having regard to the assessment criteria contained within SEPP 64 indicates that the proposal satisfies the objectives of the SEPP. Accordingly, approval is recommended.

RYDE LOCAL ENVIRONMENTAL PLAN 2014 (LEP 2014)

The subject site is zoned B4 Mixed Use under Ryde LEP 2014. The development defined under this instrument is “Business Premises” which is permissible with consent. The objectives of the B4 Mixed Use zone are as follows:

• To provide a mixture of compatible land uses. • To integrate suitable business, office, residential, retail and other development in accessible

locations so as to maximise public transport patronage and encourage walking and cycling. • To ensure employment and educational activities within the Macquarie University campus

are integrated with other businesses and activities. • To promote strong links between Macquarie University and research institutions and

businesses within the Macquarie Park corridor. The proposed provision of an business premises for the purpose of a hairdressers is consistent with the zone’s objectives as it contributes to the variety of uses within the locality as well as encouraging employment opportunities within an area that is well serviced by public transport. The following table outlines the development standards applicable to the subject site under Ryde LEP 2014:

9 STATEMENT OF ENVIRONMENTAL EFFECTS

LEP Principal Development Standard Proposal Compliance Clause 4.3 – Height of Buildings (2) The height of a building on any land is not to exceed the maximum height shown for the land on the Height of Buildings Map. Max. Building Height = 18m

The application does not seek to alter the height of the existing building.

N/A

Clause 4.4 – Floor Space Ratio (2) The maximum floor space ratio for a building on any land is not to exceed the floor space ratio shown for the land on the Floor Space Ratio Map.

The subject site has not been identified on the floor space ratio map.

N/A

Clause 5.10 – Heritage Conservation The subject site does not contain any items of heritage significance nor is it located within a Heritage Conservation Area.

N/A

Clause 5.11 – Bushfire Hazard Reduction

The subject site is not bushfire prone.

N/A

Clause 6.1 – Acid Sulfate Soils The site does not contain any acid sulphate soils.

N/A

6.4 – Stormwater management The proposed development will not affect the approved stormwater management on the site.

N/A

There are no further development standards or provisions of Ryde LEP 2014 applicable to the proposed development.

RYDE DEVELOPMENT CONTROL PLAN 2014

The following table addresses compliance with relevant development controls of the DCP:

Ryde Development Control Plan 2014 Part 4 Urban Centres Part 4.6 Gladesville Town Centre and Victoria Road Corridor 2.0 VISION 2.1 Vision Statement Gladesville Town Centre is the town centre serving Hunters Hill and the southern part of the Ryde local government area. Gladesville will serve its local communities with a wide range of

The proposed business premises will serve the locality and while utilising the existing built form and is

Yes

10 STATEMENT OF ENVIRONMENTAL EFFECTS

retail, commercial, community, entertainment, religious, residential and other uses appropriate to a vibrant and growing town centre. Gladesville Town Centre and Victoria Road will:

• serve its local communities better with a diverse range of revitalised uses;

• include major retail, commercial and residential developments on key sites;

• develop a more cohesive built form and better landscaped public domain;

• define urban spaces as outdoor rooms lined by consistent built form and street trees;

• have heritage items and conservation areas protected and enhanced;

• contain new buildings which relate in built form to existing streetscapes and heritage items;

• enhance pedestrian links and public domain design to attract people to shop, work and live in the town centre; and

• be accessible for residents and for users of the centre.

therefore consistent with the vison statement of the Gladesville Town Centre.

2.2 Vision Statement - Precincts 2.2.3 Town Centre Precinct The town centre precinct is to be transformed from a poorly functioning strip shopping centre into a genuine mixed use town centre. The existing shops and pedestrian amenity on Victoria Road have been degraded by traffic and lack of renewal in recent years. The town centre will be revitalised with new large retail developments in Cowell Street and Coulter Street, which will support the existing retail shops with parking and greater pedestrian amenity. An enhanced pedestrian network and new public spaces will be created off Victoria Road, with a new square at the end of Wharf Road and street tree planting around the Coulter Street retail development. A pedestrian bridge across Victoria Road will link the existing shops and the proposed “one-stop” parking in large new retail developments in Cowell and Coulter Streets. Better pedestrian amenity on and around Victoria Road and a greater range of services will revitalise the town centre as the focus of urban life for the communities on both sides of the town centre. The intersection of Wharf Road, Meriton Street

The proposed business premises is consistent with the vision statement of the town centre precinct of Gladesville. The proposed use activates the street front and does not generate and excessive demand for street parking as most patrons will be local patrons walking to the site.

Yes

11 STATEMENT OF ENVIRONMENTAL EFFECTS

and Victoria Road is a key site (refer section 4.3 of this part). The Clocktower marks this important intersection, which will be strongly defined by appropriately scaled buildings built to the street alignments. 3.0 OBJECTIVES AND CONTROLS 3.1 Built Form 3.1.1 Built Form Heights a. Buildings must comply with the maximum heights described in the Ryde Local Environmental Plan 2014 (LEP).

The proposed use does not result in a change in building heights.

Yes

b. Floor to ceiling height must be a minimum of 2.7 m for residential uses.

The use does not result in a change in floor to ceiling heights.

N/A

c. To ensure that the ground floor levels are adaptable over time for a range of uses, the floor to floor height at ground level in all mixed use developments is to be a minimum of 3.6 m, regardless of the initial proposed use.

The use does not result in a change in floor to ceiling heights.

N/A

3.1.2 Active Street Frontages a. Provide ground level active uses where indicated on the Active Street Frontages Control Drawing (Figure 4.6.05).

The proposed use activates the street frontage of the building.

Yes

b. Active uses contribute to personal safety in the public domain and comprise:

i. Community and civic facilities; ii. Recreation and leisure facilities; iii. Shops; iv. Commercial premises; v. Residential uses, particularly entries and

foyers, however, these must not occupy more than 20% of the total length of each street frontage.

The proposed shop is complies with this control.

Yes

c. Where required, active uses must comprise the street frontages for a depth of at least 10 m.

The proposed use occupies the entire depth of the ground floor building.

Yes

d. Vehicle access points may be permitted where Active Street Frontage is required if there are no practicable alternatives.

There are no vehicle access points in the subject building.

Yes

e. Ground floor shop fronts may incorporate security grills provided these ensure light falls

No such security grills or roller shutters proposed.

Yes

12 STATEMENT OF ENVIRONMENTAL EFFECTS

onto the footpath and that the interior of the shop is visible. Blank roller-shutter doors are not permitted. f. Serviced apartments, hotels and motels shall not have apartments at the ground level. Locate retail, restaurants and / or other active uses at the ground level.

Not a serviced apartment. N/A

3.1.3 Buildings Abutting the Street Alignment a. Provide continuous street frontages with buildings built to the street boundary in the Gladesville Town Centre and in Monash Road Precincts except as shown in the Key Sites Diagrams (Refer to Figure 4.6.06).

The proposed business premises provides a continuation of active street frontages along Victoria Road.

Yes

b. Ground level architectural features, such as recessed doors and windows, are permitted to a maximum of 400 mm from the street boundary to design out concealment opportunities and promote personal safety and security.

The existing shop front is retained and unchanged.

Yes

3.1.4 Setbacks 3.1.5 Rear Setbacks and Residential Amenity a. Provide 9 m ground level setback generally at the rear of sites fronting Victoria Road in the North Gladesville and Monash Road Precincts except where adjoining Gerard Lane and as shown in Key Sites Diagrams. Refer Figure 4.6.09 Setback I and Figure 4.6.09 Setback J.

The existing building envelope is unchanged.

N/A

b. Provide 12 m separation minimum above the ground floor between residential buildings (including existing residential buildings on adjacent sites).

The existing building envelope is unchanged.

N/A

c. Buildings fronting Victoria Road may build to the side boundary for a depth of 20 m measured from the street frontage. A side setback is then required to achieve 12 m separation between proposed and potential residential land uses.

The existing building envelope is unchanged.

N/A

d. Predominantly residential activities should be located adjoining low density residential areas including at the rear. If this is not practicable, activities that do not produce negative impacts in terms of noise, light, sound and odour are encouraged.

Surrounding uses are commercial uses.

N/A

13 STATEMENT OF ENVIRONMENTAL EFFECTS

3.1.6 Conservation Area Built Form Design Guidelines 3.2 Access 3.2.1 Minimum Street Frontage / Site Amalgamation a. Any development within the North and South Gladesville Precincts is to have a minimum 40 m frontage to Victoria Road and one driveway crossing maximum, unless it can be demonstrated that access may be achieved from the local road network.

The existing building envelope is unchanged.

N/A

3.2.2 Vehicular Access a. Provide vehicular access from the local roads network in preference to Victoria Road. This will require development of public laneways within the rear setback of most sites in the North Gladesville and Monash Road Precincts in particular.

There is no vehicle access to the site and any pedestrian or vehicle access from the rear car park or footpath remain unchanged.

N/A

b. For all existing and proposed laneways, the laneway must include a 2-way carriageway, 6 m wide (regardless of traffic generation) and a footpath along one side 1.5 m wide, to the satisfaction of Council. A setback of 0.5 m may also be required to any built form (total 8 m allowance). Note: Where a laneway is provided basement carparking may extend under the lane subject to Council approval.

The existing laneway adjacent to the building remains unchanged.

N/A

c. Gerard Lane shall be extended to create a connection running from Osgathorpe Street to Gerard Street.

Not located in proximity to Gerard Lane

N/A

d. Where a new lane is proposed to extend an existing lane, the new lane must be designed to seamlessly connect to the existing lane. The new lane may be required to be wider than the existing to Council’s satisfaction to ensure adequate sightlines and safety to take into account the cumulative traffic demand in relation to the development capacity of the area, vehicular types and other relevant matters.

A new lane is not proposed. N/A

3.2.3 Parking

14 STATEMENT OF ENVIRONMENTAL EFFECTS

a. Provide publicly accessible parking to support retail, entertainment and commercial land uses, church and educational institutions as shown on the Parking Control Drawing (Figure 4.6.12) below, to Council’s satisfaction.

The public car park at the rear of the site is able to service the premises.

Yes

b. The quantity of publicly accessible parking within the Town Centre Precinct shall equal or exceed existing public parking.

The existing quantity of public parking remains unchanged.

Yes

3.3.3 Landscape Character a. Create a consistent planting theme with a number of species to ensure that the planting gives a visual coherence. Build on the palette of existing species in streets.

There are no changes proposed to existing landscaping of the site.

Yes

4.3 Key Sites Built Form and Public Domain Controls 4.3.4 Block 11 (Council Carpark) Built Form Controls a. Provide commercial or retail uses to the ground floor along Victoria Road.

Commercial use is proposed in the subject premises which fronts Victoria Road.

Yes

b. Provide community and retail/commercial uses to the ground floor along Pittwater Road. Encourage community activities at the ground floor level.

Not located on Pittwater Road.

N/A

c. Provide residential or commercial uses on the upper floors.

The upper floor of the building has approved commercial use.

Yes

Street Frontages d. Provide a landscaped setting for the Presbyterian Church on the corner of Pittwater Road and Victoria Road, with a row of closely spaced trees planted between future development and the rear façade of the church

There are no changes to the public domain or existing landscaping.

N/A

e. Setback the building on Pittwater Road to create a forecourt to the building, addressed by the library, child care centre and possible retail uses.

The site does not front Pittwater Road.

N/A

f. Provide a continuous active frontage at ground level abutting the property boundary on Victoria Road

The proposed salon will contribute to the active street frontage at ground level.

Yes

Building Heights g. Provide development in accordance with Block 11 Built Form Plan (Figure 4.6.29) per building

There are no changes proposed to the existing building envelope.

N/A

15 STATEMENT OF ENVIRONMENTAL EFFECTS

heights in storeys, measured to the ceiling of the top most floor. Note: The articulation of the top floor in the 3 dimensional building envelope drawing (Figure 4.6.28) is indicative of a top floor treatment, and is not a development control. Building Depth and Separation h. Provide building depth and separation in accordance with Block 11 Built Form Plan (Figure 4.6.29).

There are no changes proposed to the existing building envelope.

N/A

Building Setbacks i. Provide setbacks to Pittwater Road as shown on Block 11 Built Form Plan (Figure 4.6.29).

There are no changes proposed to the existing building envelope.

N/A

j. The ground, first and second floors along Victoria Road are to be built to the existing street boundary.

There are no changes proposed to the existing building envelope.

N/A

k. The upper floors along Victoria Road are to be set back a minimum 5 metres from the edge of any balcony or building façade. Minimising Vibration, Noise and Air Pollution in Residential Buildings Near Busy Roads

There are no changes proposed to the existing building envelope.

N/A

l. Design to minimise vibration, noise and air pollution in the internal layout and materials selection of residential buildings. Development must comply with NSW Planning & Infrastructure, Development Near Rail Corridors and Busy Roads - Interim Guidelines.

The proposed use will not increase the impact of noise and vibration from Victoria Road.

Yes

m. Internal circulation corridors, bathrooms, laundries and other non-habitable spaces should be located adjacent to the busy road.

The store entry (internal circulation space) is located adjacent to Victoria Road.

Yes

o. Living rooms and primary balconies should be located and oriented away from the main road. Additional techniques to minimise the impacts of a busy road include glazed balconies or wintergardens, louvred balcony screens and double glazing.

There are no living rooms or balconies proposed (change of use proposed)

N/A

p. Cross ventilation is to be maintained by means such as glass and metal louvres, and cross over or two storey apartment types.

The subject premises occupies the ground floor and cross ventilation is possible.

Yes

Part 7.1 Energy Smart, Water Wise

16 STATEMENT OF ENVIRONMENTAL EFFECTS

2.4 New Shops, Industrial and Commercial Premises (including those Contained in a Mixed-use Development). a. The total anticipated energy consumption for the base building is no greater than 450 Mega

Joules/ annum/metre square [MJ/am2] (commercial) and 900 Mega Joules/annum/metre

square [MJ/am2] (retail).

There are no changes to the base building proposed.

N/A

b. Any hot water system/s installed as part of a development or as a replacement must consider the most efficient option available to minimise greenhouse gas emissions (see diagram below as a guide). Note: The Federal Governments Energy Rating website has a comprehensive list of efficient hot water systems rated through the Minimum Energy Performance Standard (MEPS) and is currently working on a rating scheme. The preferred system should be no worse than heat pump. http://www.energyrating.gov.au

The existing hot water system is used.

N/A

c. Any products installed as part of a development or as a replacement that are regulated for energy efficiency under the Australian Standards for Products and/or Minimum Energy Performance Standards (MEPS) must achieve a Minimum energy rating of 4.5 stars. Note: Products that carry an energy star label and are regulated under MEPS include refrigerators, freezers, clothes washers and dryers, dishwashers and air conditioners. The energy star rating as well as date of purchase of the product should be visible on the product at all times. The Federal Governments Energy Rating website has a comprehensive list of efficient appliances based on star ratings. http://www.energyrating.gov.au

All appliances used have low energy consumption ratings.

Yes

d. Water Efficient Fixtures: where new or replacement fittings are required, Shower heads shall be at least 3 star rated water efficient 4 star dual flush toilets, 4 star taps (for all taps other than bath outlets and garden taps) and 3 star urinals, bathroom and kitchen taps shall be fitted with aerators; and water closets shall have a dual flush cistern.

All fixtures are water saving as required by Australian Standards.

Yes

17 STATEMENT OF ENVIRONMENTAL EFFECTS

e. The installation of energy efficient lighting, motion detectors and dimmers where appropriate are encouraged.

All lighting is LED low energy consumption.

Yes

f. Any products installed as part of a development or as a replacement that are regulated for water efficiency under Water Efficiency Labelling and Standards (WELS) Scheme must obtain a Minimum WELS rating of 4.5 stars. Products that carry a star water label and are regulated under WELS include clothes washing machines and dishwashers. The water star rating as well as date of purchase of the product should be visible on the product at all times. The Federal Governments WELS website has a comprehensive list of efficient appliances based on star ratings. http://www.waterrating.gov.au

All fixtures are water saving as required by Australian Standards.

Yes

Information to be submitted with Application g. Energy Efficiency Performance Report. This report shall include evidence from a suitably qualified consultant to confirm compliance with the total anticipated energy consumption. Details of complying water heater type and location on plan information. Site Analysis. Details of energy and water efficient appliances.

All appliances and products used are energy and water efficient as required by Australian Standards.

Yes

Part 7.2 Waste Minimisation and Management 2.8 Commercial and Retail a. All commercial premises must have a dedicated waste and recycling storage room or area, which has adequate storage space to meet the needs of the land use activity. Indicative waste generation rates for various commercial developments are listed in Schedule 3 Commercial Waste/Recycling Generation Rates attached to this Part. Note: Depending upon the size and type of the development, it may be necessary to include a separate waste/recycling storage room/area for each tenancy.

Specialist commercial waste contract for hairdressers is engaged for the proposed use.

Yes

18 STATEMENT OF ENVIRONMENTAL EFFECTS

b. All waste and recycling storage rooms and areas must be designed and constructed in accordance with the requirements of Schedule 4 (refer S4.2 Waste and Recycling Storage Rooms and S4.5. External Waste and Recycling Storage Areas).

There are no waste and recycling rooms for the existing building.

N/A

c. The waste and recycling storage room or area must provide separate containers for the separation of recyclable materials from general waste. Standard and consistent signage on how to use the waste management facilities should be clearly displayed.

There is sufficient area for waste storage provided to comply with this control.

Yes

d. Space must be provided in each occupancy for the temporary storage of garbage and recyclables generated in that area.

There is sufficient area for waste storage provided to comply with this control.

Yes

e. Hazardous and special waste is to be stored in accordance with relevant occupational, health and safety and environmental protection legislation.

There are no hazardous or special waste (no sharps applicable as skin penetration is not proposed)

Yes

f. In multi storey developments, consideration must be given to the convenient transportation of waste and recycling from the various floors to the central storage area. Such transportation system may include a passenger or goods lifts, or a garbage chute system.

Not a multi storey development.

N/A

g. Separate space must be allocated for the storage of liquid wastes and oils etc. The liquid waste storage areas must be undercover and bunded to prevent the escape of spills or leaks.

There is sufficient area for waste storage provided to comply with this control.

Yes

h. Space must be provided for the installation of grease traps or other wastewater pre-treatment equipment required by Sydney Water Corporation. Grease traps must be installed outside the building or in a dedicated grease trap room. Grease traps must not be accessed through food handling and storage areas.

Grease trap is not applicable for this development.

N/A

i. In premises where more than 50 litres of seafood, poultry or meat waste per day is generated, the waste must be stored in a refrigerated waste room until collected or have that waste collected daily.

Premises is not a food premises.

N/A

j. Space is to be provided for compactors and for any other equipment necessary to manage the

No compactors proposed. N/A

19 STATEMENT OF ENVIRONMENTAL EFFECTS

waste and recycling likely to be generated on the premises. Sufficient space is also required for storage of the waste (such as cardboard boxes) prior to processing. k. Sufficient space in the development must be allocated to store bulky items such as used pallets and crates to prevent illegal dumping in the public domain.

No such bulky items to be stored at the premises.

N/A

L. Adequate access must be provided for the users, waste collection staff and collection vehicles. Where collection vehicles are required to drive into a property to collect waste and recycling:

i. The site must be designed to allow collection vehicles to enter and exit the property in a forward direction with minimal need for reversing and to be operated with adequate clearances; and

ii. The driveway and any basement space needed are to be suitable for collection vehicles in terms of pavement strength, spatial design, access width, and height clearances. Appendix C Collection Vehicles and Appendix D Vehicle access/Turning Circles under the Better Practice Guide for Waste Management in Multi-Unit Dwellings, DECC 2008 are to be used as a guide.

Adequate space is provided for waste collection which occurs at the rear of the building.

N/A

Schedule 3 COMMERCIAL WASTE / RECYCLING GENERATION RATES Hairdresser Beauty Salon Waste Generation: 60L/100m2 floor area/week Recyclable Material Generation: Variable

The waste generation will not exceed this rate and operational waste management provisions will be capable of managing these volumes.

Yes

Schedule 4 DESIGN REQUIREMENTS S4.5. External Waste and Recycling Storage Areas

a. All external waste and recycling storage areas in commercial and industrial developments must be designed and constructed in accordance with the following requirements:

• The waste and recycling storage area must be of adequate dimensions to store all garbage and recyclable wastes generated on the premises between

Sufficient areas are provided for waste disposal and recycling. Floor waste are provided for all wet areas.

Yes

20 STATEMENT OF ENVIRONMENTAL EFFECTS

collections and allow easy access for users and servicing purposes.

• The waste and recycling storage area must be roofed to prevent the entry of rainwater. The ceiling must be of a minimum height to enable access for cleaning and the lids of bins to be fully opened.

• The floor of the waste and recycling storage area must be constructed of concrete finished to a smooth even surface.

• All uncontaminated stormwater from the roof and uncovered paved areas of the site must be directed away from the waste and recycling storage area and be drained to Council’s stormwater drainage system.

• Where garbage or putrescible waste is to be stored, the floor must be graded to a floor waste connected to the sewerage system. The floor waste must be fitted with an in-floor dry basket arrestor approved by Sydney Water Corporation.

• Where garbage or putrescible waste is to be stored, a tap with a hose connection must be provided in or adjacent to the waste and recycling storage area to facilitate cleaning.

• The waste and recycling storage area must be adequately screened from the street to prevent the creation of unsightly conditions.

Stormwater will be managed by the existing building’s services.

Part 9 Other Provisions 9.1 Signage 2.0 GENERAL REQUIREMENTS FOR ALL SIGNAGE 2.1 Signage Content a. A sign must be either:

• A business identification sign or a building identification sign as defined in Ryde Local Environmental Plan 2014; or

• A directional sign, that is a sign that directs persons to development on the land to which it is displayed.

• Billboard Type Signage and Advertising Structures are prohibited.

There are three business identification sign (under awning light box and awning facia sign) the awning facia signs replace existing signs which were much more visually dominating than the newly installed signs. Furthermore, these signs comply with Subdivision 4

Yes

21 STATEMENT OF ENVIRONMENTAL EFFECTS

Clause 2.87 (Facia Signs) and Subdivision 5 Clause 2.93 (Under awning signs) of SEPP Exempt and Complying Development Codes 2008.

2.2 Language a. advertising signs are to be displayed in the English language but may include a translation into another language using letters or characters that are no larger than the English language letters or characters.

All signage is in English. Yes

b. Any translated message must be accurate and complete.

All signage is in English. N/A

2.3 Number of Signs a. Visual clutter through the proliferation of signage and advertising structures is not permitted. Note: Excessive signage usually has an opposite effect to its original intention. The cluttering causes visual pollution and confusion to the observer. Having fewer, but clearer advertising assists not only the advertiser, but also the appearance of the building and the overall streetscape. Excessive signage tends to have a “domino effect”, by competing with neighbouring premises in order to gain the advantage in exposure.

There are three business identification signs which do not result in visual clutter.

Yes

2.4 Design, Safety and Maintenance b. All signs must be sympathetic to, and compatible with the architectural style and finishes of the building to which they are attached, so as to look an integral part of the building rather than a “tack-on” appearance. They should not obscure existing architectural features such as windows.

The three business identification signs are in keeping with the architectural style of the building.

Yes

c. Signs are to be unobtrusive in design, colour, height and scale, so as not to impact adversely on the streetscape.

The three business identification signs are text adhered to the facia or light box of a recessive size and colour.

Yes

22 STATEMENT OF ENVIRONMENTAL EFFECTS

d. Signs must be attractive and professionally written as well as being simple, clear and efficient. Note: A well-designed sign inspires and promotes confidence in the business or product advertised

The three business identification signs are professionally printed and installed.

Yes

e. Signs should be located at a height which avoids impact from footpath maintenance vehicles and discourages vandalism.

The subject signs are integrated with the existing facia and light box.

Yes

f. Signs facing roads with high traffic volumes, traffic lights or major intersections may be referred to other relevant authorities such as the Roads and Maritime Services for comment.

Not considered necessary as signs comply with exempt development provisions.

N/A

g. Signs that are prone to deterioration in appearance and condition, and may order removal of objectionable or unsightly advertisements, pursuant to the provisions of Section 124 of the Local Government Act 1993. Note: Council will give due attention to all applications with respect to possible distraction of motorists due to illumination, position, colours, design and proximity to traffic lights.

The subject signs are not prone to deterioration.

N/A

2.5 Illuminated Signs a. The lighting intensity and hours of illumination must not unreasonably impact on any residential properties adjoining the sign or that is within its locality.

The subject signs are not illuminated.

N/A

b. The lighting intensity of a sign must be capable of modification or control after installation.

The subject signs are not illuminated.

N/A

c. Illuminated signs must minimise the spill effects or escape of light beyond the subject sign and must not compromise safety for pedestrians, vehicles or aircraft.

The subject signs are not illuminated.

N/A

d. Illumination of a sign (with the exception of floodlit signs) must not be external to the sign i.e. surrounding a sign. Illumination must be part of the advertisement.

The subject signs are not illuminated.

N/A

e. Electric wiring to illuminated signs is to be concealed.

The subject signs are not illuminated.

N/A

f. Depending on its location and its relationship to residential properties, Council may require that

The subject signs are not illuminated.

N/A

23 STATEMENT OF ENVIRONMENTAL EFFECTS

illumination be controlled by automatic time clocks extinguishing illumination between 11 pm and 6 am, or as is considered reasonable in the circumstances. 2.7 Corporate Branding a. it is permitted only in business and industrial zones;

No corporate branding proposed.

N/A

b. it is permitted only on one sign per site;

No corporate branding proposed.

N/A

c. it is permitted only on a business directory board or pylon sign;

No corporate branding proposed.

N/A

d. it is to occupy a maximum area of 0.6 m2 ;

No corporate branding proposed.

N/A

e. it is to consist of words, symbols and shapes;

No corporate branding proposed.

N/A

f. the use of corporate colours is restricted to permitted signage only and the use of corporate colours in the external finishes of a building is prohibited.

No corporate branding proposed.

N/A

2.8 Other Prohibited Signage a. Development for the purpose of erecting or displaying any of the following types of advertisements and signs is prohibited General advertising; Signs not defined as a temporary sign made of canvas, fabric, similar sheet material or any type of airborne sign; Signs affixed to the surface of a public footway or public roadway; Signs that obscure obstruct or interfere with any road traffic signs or motorists vision or otherwise adversely affecting road safety; and Signs prohibited under the Tobacco Advertising Prohibition Act, 1991 or any other Act.

No such signage proposed or installed.

N/A

3.0 SIGNAGE REQUIREMENTS BY TYPE OF ZONE AND LOCATION 3.2 Business Zones 3.2.1 Sign options for Office and Retail Shop - Fronts within Shopping Precincts or Areas a. Sign options in business zones are:

• An Illuminated Under Awning Sign (one per site);

• Fascia Sign;

The existing signs are facia signs and drop awning sign.

Yes

24 STATEMENT OF ENVIRONMENTAL EFFECTS

• Top Hamper Sign; • Window Sign; • Drop Awning Sign; • Under Awning Bracket Sign; • Real Estate Sign; • viii.Temporary Sign; • Flush Wall Sign (Only if it relates to

activity at that level); and • Internally Illuminated Sign.

3.2.2 Extent of Signage Permitted For Two or More Storey Buildings a. Maximum Sign Area – The total area of signs to be erected on a building (this includes elevations)

should not exceed 1.5 m2 per 1 metre of frontage of the property to the street.

The shop front has a width of 4.49 metres and the total area of the signage measures 4.76m2

Yes

Front Elevation – All signage above the ground floor or awning level of a building must relate to the activity or use of the building at the first floor level. The maximum area of signs above the ground floor or awning level on the front elevation should not exceed 15% of the area of the elevation situated at that level

All signage for the proposed use is at or below the awning level.

Yes

Side and Rear Elevations – The maximum area of signs on side or rear walls should not exceed 15% of the area of each elevation visible from a public place. Where there is a break in any elevation the maximum coverage should apply to each part of that elevation.

There are no signs on the side and rear walls.

N/A

Part 9.2 Access for People With Disabilities 4.1.7 Class of Building – Class 6 A shop or other building for the sale of goods by retail or the supply of services direct to the public, including: an eating room, café, restaurant, milk or soft-drink bar; a dining room, bar shop or kiosk portion of a hotel or motel; a hairdresser’s or barber’s shop, public laundry, or undertaker’s establishment;

The proposed use is capable of complying with AS1428.2.

Yes

25 STATEMENT OF ENVIRONMENTAL EFFECTS

market or sales room, showroom, or service station. Existing building/change of use or alterations - Must comply with all applicable provisions of this Part where there are structural alterations, major refurbishment or significant change of use affecting a substantial proportion of the gross floor area of the premises. - Where there is minor refurbishment to an existing building, accessibility shall not be made worse.

The proposed use is capable of complying with AS1428.2. The accessibility of the premises remains consistent with the previous use.

Yes

5.3 Continuous Accessible Path Of Travel The provision of a continuous accessible path of travel is the basic tenet on which access to premises is based. It allows people with disabilities to move without restriction into and throughout the building or other area. In general, it is expected that all parts of buildings will be accessible to people with disabilities. To do this requires careful planning so that access is not prevented by the inappropriate design or construction of minor aspects of the building that undo or negate the efforts that have been made in other areas. Note : There is little point in providing an accessible parking bay if a wheelchair user cannot get from the parking area and through the front door because of a step at the door. There is little point in making the entrance accessible if access throughout the building is impeded by steps or narrow doors or obstacles placed in the path of travel. Australian Standard, AS1428.2 provides technical details of what needs to be done to ensure a continuous accessible path of travel for most people with disabilities and should be referred to for complete specifications. Some of the major factors, however, are explained below. (AS1428.2 Clause 7)

Continuous path of travel is provided for the entire service area.

Yes

A wheelchair user needs a minimum of 1200 mm except at doors where more space is required. In addition, passing spaces need to be provided every 6 metres to allow two wheelchair users to pass. (AS1428.2 Clauses 6.1 to 6.5)

A minimum 1921mm wide pathof travel is provided in the service area.

Yes

5.5 Changes in Level The steps are at the rear of the store which access the

Yes

26 STATEMENT OF ENVIRONMENTAL EFFECTS

Even small steps or lips can prevent some wheelchairs from movement and may also be a hazard to ambulant people with disabilities. Any change in level that exceeds 3 mm must be ramped or an alternative access means provided (e.g. a lift). (AS1428.2 Clause 6.6)

storage area. The service area does not have any steps.

5.6 Vertical Clearance People who have visual impairment or who are blind need to be sure that the path of travel is free from obstacles that might strike them on the head or upper body. There must be clearance above the path of at least 2000 mm. (AS1428.2 Clause 6.7)

There are no vertical obstacles.

Yes

5.7 Ramps and Landings Wheelchairs are difficult for many users to push up slopes. This is because of the effort involved and because a steep slope may tip the wheelchair over backwards. Generally ramps must not have a gradient greater than 1:14.

The ramp at the entry remains unchanged and is less than 1:14 in grade.

Yes

5.8 Ground and Floor Surfaces Floor surfaces must be slip resistant so as not to be a hazard to people with disabilities. Where carpet is used it must provide a firm surface and be attached so that there are no changes in level greater than 3 mm between the carpet and any other surface. (AS1428.2 Clause 9)

There are no changes in level more than 3mm on the ground floor and all surfaces are non-slip.

Yes

5.9 Approaches and Entrances All public entrances and employee entrances are to be accessible to people with disabilities. Thresholds are to be avoided but where they are essential, they must be no higher than 56 mm and be ramped using a threshold ramp with a gradient of no more than 1:8. (AS1428.1 Clause 11.2)

The main entry is ramped. Yes

5.10 Doors and Doorways People who use wheelchairs and people using other mobility aids need clear door openings of at least 960 mm wide to enable equitable access. There also needs to be sufficient circulation space at doors to allow people with disabilities to open and close the doors independently. Where they can be used, automatically operated sliding doors offer a good solution for most people with disabilities. Where revolving doors and turnstiles

The main entry has a clear opening of 4.49m

Yes

27 STATEMENT OF ENVIRONMENTAL EFFECTS

are installed, an alternative entrance shall be provided. (AS1428.2 Clause 11) 5.11 Lifts Lifts should be provided in easily accessible locations in all buildings of more than two levels, excluding carparking levels, as required by Part B (Coverage of Development Control Plan) of this document. Lifts must be able to be operated independently by people with disabilities. There must be sufficient room for a wheelchair user to turn around in the lift car and control buttons are to be within reach of a wheelchair user. Handrails are to be provided. (AS1428.2 Clause 12) Information in lifts must be provided in tactile, aural and visual formats. Visual information must be able to be read by a person with visual impairment. (AS1428.4)

No lifts in the subject premises.

N/A

5.12 Tactile Ground Surface Indicators People who are visually impaired or blind need to be warned of hazards in or adjacent to the path of travel. This can be done by including tactile indicators in the path of travel ahead of hazards such as ramps, steps, roadways or before overhead obstacles that are close to the path of travel. In addition, directional information can be provided by appropriate tactile indicators at points in the path of travel where there are changes of direction. (AS1428.4)

Not considered necessary as there are no hazards throughout the path of travel.

N/A

5.13 Stairways, Escalators and Moving Pathways Some people with ambulant disabilities prefer stairs to ramps. However, any stairs, escalators or moving pathways used must be provided in addition to the continuous accessible path of travel and not as part of it. Stairs may have a rise of 150 to 165 mm and a tread of 275 to 300 mm. However, where possible, the rise should be 95 to 105 mm with a tread of 575 to 600 mm which suits people using assistive devices such as walking frames. Stairways are to have dual handrails on both sides of the stairway. The top rail is to be 865 to 900 mm from the top of a step and the lower rail

There are no stairs to facilities.

Yes

28 STATEMENT OF ENVIRONMENTAL EFFECTS

is to be 665 to 700 mm from the top of a step. Railings are to be a minimum of 30 and a maximum of 50 mm diameter. (AS1428.2 Clause 10.1) 5.14 Lighting Poor lighting can cause a safety hazard for all people. People with disabilities, particularly people with vision impairment, need good lighting for both safety and so they can find their way around. Lighting should not glare nor reflect unduly off surfaces as this can cause confusion and disorientation. In general, the minimum lighting level that complies is 150 lx. Some areas, such as toilets, counter tops and general displays, require more light – up to 300 lx.

All lighting is of appropriate brightness.

Yes

5.15 Gateways and Checkouts If access to, or egress from, a premises is through a gateway or checkout, care needs to be taken that people with disabilities can negotiate it. Gateways and checkouts suitable for people with disabilities are to be identified by the international symbol for access. Turnstiles are not appropriate for people with disabilities. An opening of at least 850 mm is required and any coin device or ticket machine is to be located at a height of between 800 and 900 mm to enable wheelchair users to use it. Any barrier must be at least 1200 mm past the ticket or coin feed point to allow a wheelchair user access.

Not checkout or gates in the subject premises.

N/A

5.16 Parking Areas Many people with disabilities use motor vehicles, at least in part because most public transport is inaccessible.

All access is via the front entry, parking is street parking or the parking at the rear via the laneway.

Yes

5.15.1 Off Street Parking Off Street Parking Parking spaces for people with disabilities are to be located close to exits of the parking area or close to entrances to premises (including close to lifts, ramps or walkways). There must be a continuous accessible path of travel from all parking spaces for people with disabilities to entrances to the premises.

No off street parking applicable to this premises.

N/A

29 STATEMENT OF ENVIRONMENTAL EFFECTS

In undercover parking areas, lifts are to provide access to all levels. The ground surface of parking bays is to be smooth, but non-slip and have a slope in any direction not exceeding 1:40. (There are special provisions for outdoor car parks – see AS2890.1 Clause 2.4.5 (a)). Parking spaces are to be a minimum of 3660 mm wide to allow a wheelchair user to fully open the car door and then transfer from the car to the wheelchair. Wheelchairs are often carried on the roof of the car using a wheelchair hoist. A vertical clearance of at least 2500 mm is required to allow the hoist to operate. This clearance must extend from the entrance to the parking bays for people with disabilities. Parking spaces are to be identified by the international access symbol. Where boom-gates are used at either the entrance or the exit, any ticket machine is to be within reach of a driver seated in the car and, for drivers who cannot operate the ticket machine, an intercom system provided that can be operated from the driver’s seat of the car. Class 5, 6, 7 and 8 In parking areas with more than 10 spaces, 3% of spaces are wide bay. That is : 10 to 33 spaces - 1 space 34 to 66 spaces - 2 spaces 67 to 100 spaces - 3 space 101 to 133 spaces - 4 spaces, etc

No on-site parking is available.

N/A

5.17 Sanitary Facilities Accessible sanitary facilities are to be provided in every location where other sanitary facilities are provided. Many people with disabilities need assistance with toileting and this is often provided by a person of the opposite sex to the person with a disability. It is therefore required that accessible facilities should be located so they can be accessed without the need to enter a male only or female only area. Generally, one unisex accessible facility is required to be provided near each block of male and female facilities. Developers are particularly urged to consult AS1428.2 Clause 15 before settling on a sanitary facility design.

Sanitary facilities are accessible with direct path of travel. All sanitary facilities were existing and were no constructed as part of the works included in the BIC.

Yes

30 STATEMENT OF ENVIRONMENTAL EFFECTS

Accessible sanitary facilities will be a minimum of 2300 mm by 1900 mm, unless a wash basin or other facility is also provided in the same area, in which case extra space is required. As some wheelchair users are able to transfer to one side only, where more than one accessible sanitary facility is provided there will equal numbers of facilities that allow transfer from wheelchair to toilet from the left and from the right hand side of the wheelchair. At least one emergency call button will be provided in each facility. Grabrails will be provided which comply with AS1428.2 Clause 10.2. (AS1428.2 Clauses 15.1 to 15.3) In each single sex facility there will be a cubicle that people with ambulant disabilities can use. It will comply with AS1428.2 Figure 12. 5.18 Washbasins Washbasins will allow a wheelchair user to sit front-on to the basin with room under it for clearance over the person’s knees. Provision should also be made for an area which allows for the easy placement of such things as hair brushes

Wash basin was existing and did not form part of the works under the BIC.

N/A

5.19 Shower Facilities Where shower facilities are provided, they will also be provided for people with disabilities. The accessible shower facility may be incorporated into the accessible sanitary facility provided sufficient circulation space is provided. The minimum circulation space required for an accessible shower is 1600 by 2350 mm. A fold-away seat and grabrails will be provided. A shower hose will be provided. An adjustable temperature control valve will be installed to prevent scalding. There shall be two levers on which to hang the shower hose.

No shower facilities proposed.

N/A

5.121 Controls, Handles, Fixtures Many people with disabilities are limited in their reach, in their strength and in their hand function. Controls for such things as lights, doors and power outlets must be designed and positioned to allow their operation by people with disabilities. In addition there needs to be sufficient contrast between the control and its background to enable a person with vision impairment to detect it.

No such controls applicable. N/A

31 STATEMENT OF ENVIRONMENTAL EFFECTS

Door handles must be able to be operated with one hand and be of a design that enables a person with no grip to use it – a “D” handle will often suffice where the door is unlocked. Lever handles allow people with limited hand function to open locked doors. Controls are to be located no less than 900 and no more than 1100 mm from the floor. Switches are to be no less than 500 mm from any corner to allow a wheelchair user to reach them. Should an outwards opening door be used, for example in a sanitary facility, a horizontal handrail or pull bar will be fitted to the inside of the door. A preferable solution is the use of sliding doors as internal doors. 5.22 Symbols and Signs Access will be identified by use of the international symbol for access. The figure will be white on a blue background. In general, a sign using the international symbol for access will face in the direction of the travel and may also include an arrow and a sign or word indicating a facility. Where hearing augmentation is provided it will be notified by use of the international symbol for deafness. Signs need to be clear and easily understood. The height of lettering and the colour contrast between lettering and the background needs to be sufficient to ensure signs can be read from a distance. For example, for a sign to be read from 2 metres the lettering must be at least 6 mm high, to be read from 12 metres, 40 mm high and from 50 metres, 150 mm high. (AS1428.2 Clause 17.2) Signs are to be illuminated without glare or reflection. (AS1428.2 Clause 17.3) Signs are to be located so they can be read from both a standing and a seated position. In general, signs are to be placed not more than 1600 and not less than 1400 mm from the floor. (AS1428.2 Clauses 17.4 and 25)

No such signage required for the proposed use.

N/A

5.23 Auditoriums and Assembly Areas Many people with disabilities patronize theatres, concert halls and the like. As often as other people they are accompanied by family or friends who may or may not have a disability. Seating in

No such development proposed.

N/A

32 STATEMENT OF ENVIRONMENTAL EFFECTS

these kinds of venues needs to be designed so that people with disabilities have a range of options as to where they sit. That is, seating should be available to people with disabilities in all price areas and levels of the venue. Provision must be made for people with disabilities to sit with others with disabilities and with others who do not have a disability. The surface of any wheelchair seating space will have a gradient no greater than 1:40. Seating for people with disabilities will be accessible along a continuous accessible path of travel from the street or car parking area. Any stage or podium is to be accessible by ramp or other means. The stage or podium will have sufficient circulation space for a wheelchair user. All controls will be able to be operated by a seated person. 5.24 Listening Systems for Hearing Augmentation Many people with hearing impairment can benefit from a hearing augmentation system which amplifies sound and in some cases can be used by people with “T” switches on their hearing aids. Other systems use supplied headphones or other devices. Where a sound amplification system is provided, at least 10% of the audience area in each classification of seating will be provided with a hearing augmentation system. The several types of hearing augmentation systems that are available are detailed in AS1428.2 Clause 21

No such systems required. N/A

5.25 Background Sound Levels For hearing systems to be effective, there needs to be a low level of background noise. Particular care should be taken with the installation of air conditioning and computer systems. (AS1428.2 Clause 20 & AS2107)

No amplified music proposed which may affect hearing systems.

N/A

5.26 Furniture and Fitments People with disabilities need to be able to use the furniture installed in premises. Tables, counters and worktops all need to be designed so that access is provided. No one table height suits all people with disabilities. Therefore it is necessary to provide for adjustment to table and worktop height or,

Wheelchairs may be used to access service tables and counters.

Yes

33 STATEMENT OF ENVIRONMENTAL EFFECTS

where this is impractical, to provide tops at a range of heights between 700 and 850mm. Tables, counters and worktops also need to have clearance under them for a wheelchair user. Generally this clearance should be no less than 710mm. The width of clearance under a table or counter must be no less than 800 mm. 5.27 Street Furniture Street furniture will not be situated so that it causes a hazard to people with disabilities. Items such as seats, tables, drinking fountains, planter boxes, etc will be positioned at least 500 mm from any accessible path of travel. All seating should have armrests at a height of 210 to 300 mm above the seat, and have a seat height of 450 mm unless a high proportion of elderly people are likely to use the seating. In this case at least some of the seats are to have a seat height of 520 mm which enables people to stand up from the seat more easily.

No street furniture proposed.

N/A

5.28 Emergency Warning Alarms Emergency warning systems need to include both visual and audible alarms so that as many people as possible can be alerted to any emergency. Signs that warn of danger are to be placed sufficiently ahead of the hazard to allow avoidance.

No audible alarm systems. All essential fire services comply with relevant Australian standards.

N/A

5.29 Emergency Egress Emergency exits need to be accessible to people with disabilities. Where egress is required from upper levels, the use of fire rated lifts or other means may be required. There is no Australian Standard dealing with this issue, however the Human Rights and Equal Opportunity Commission’s Advisory Notes on Access to Premises provide advice.

Emergency exit is the main entry which is accessible.

Yes

5.30 Outdoor Areas – Parks, etc It is just as important for people with disabilities to have access to outdoor areas as it is for them to have access to buildings. Continuous accessible pathways of travel are to be provided from all entrances to all of the facilities in the area – e.g. toilets, change rooms, barbecues, activity areas, tables and seats.

No outdoor areas proposed. Yes

34 STATEMENT OF ENVIRONMENTAL EFFECTS

In addition, all facilities are to be constructed so as to provide access to them or to enable their use by people with disabilities. 5.31 Infrastructure People with disabilities need to be able to move between buildings and between transport nodes and their destinations. This means all train stations, bus interchanges, footpaths, shopping malls and the like must not only be accessible in themselves but also linked by continuous accessible paths of travel. Kerb ramps are particularly important and must conform to AS1428.1. To ensure that wheelchair accessible buses can be effective, all kerbs must be a minimum of 150 mm high. When footpath upgrading occurs, there needs to be a concerted effort to use the opportunity to increase access to shops. This might involve encouraging the shopkeeper / owner to meet some of the cost of making their shop accessible. Shops can often be made accessible by ramps within the shop, perhaps in combination with a threshold ramp on the footpath.

The storey is accessible to the public domain.

Yes

Part 9.3 Parking Controls 2.0 PARKING REQUIRED IN RESPECT OF SPECIFIC USES 2.1 General a. Where the calculation of the parking required results in a fraction, the parking requirement will be rounded up to the nearest whole number.

The is no on-site parking provided which is consistent with the previous uses of the building and buildings in the immediate locality fronting Victoria Road. The premises is services of street parking on Victoria Road and the public parking available at the rear of the site.

Yes

35 STATEMENT OF ENVIRONMENTAL EFFECTS

7. ENVIRONMENTAL PLANNING AND ASSESSMENT ACT 1979 –

MATTERS FOR CONSIDERATION

As per Section 4.15(1) of the Environmental Planning and Assessment Act 1979 the subject application is consistent with the required matters for consideration as demonstrated below.

In determining a development application, a consent authority is to take into consideration such of the following matters as are of relevance to the development the subject of the development application:

a) the provisions of:

(i) any environmental planning instrument,

The relevant environmental planning instrument (Ryde LEP 2014) has been addressed under Section 4 of this report.

(ii) any proposed instrument that is or has been the subject of public consultation under this Act and that has been notified to the consent authority (unless the Secretary has notified the consent authority that the making of the proposed instrument has been deferred indefinitely or has not been approved),

There are no relevant proposed instruments pertaining to the subject site.

(iii) any development control plan

The Ryde DCP has been addressed under Section 5 of this report.

(iii) any planning agreement that has been entered into under section 7.4, or any draft planning agreement that a developer has offered to enter into under section 7.4,

There are no relevant planning agreements pertaining to the site.

(iv) the regulations (to the extent that they prescribe matters for the purposes of this paragraph),

The proposed development is not inconsistent with any of the relevant regulations.

(v) (Repealed)

that apply to the land to which the development application relates,

b) the likely impacts of that development, including environmental impacts on both the natural and built environments, and social and economic impacts in the locality,

The proposal will not create any adverse impacts to both the natural and built environments, nor will it have any adverse social or economic impacts in the locality.

c) the suitability of the site for the development,

The site is appropriately zoned for the proposed development and the proposal is in keeping with the intended land use of the site.

d) any submissions made in accordance with this Act or the regulations,

36 STATEMENT OF ENVIRONMENTAL EFFECTS

It is understood that the application will be notified to surrounding landowners as per requirements of the Environmental Planning and Assessment Regulations 2000 and The Ryde DCP.

e) the public interest.

The proposal is considered to be in the public interest by providing a restaurant within a Local Centre zone.

8. CONCLUSION

The proposed hairdresser salon and signage is permissible within the B4 Mixed Use zone and is consistent with all zone objectives and desired outcomes.

The proposed development complies with the objectives and development controls of the Ryde Local Environmental Plan 2014 and Ryde Development Control Plan 2014. The proposed design and use has consideration and is sympathetic to the amenity enjoyed by adjoining surrounding developments and locality while appropriately and effectively addressing the attributes and characteristics of the site. On the basis that the proposal results in no adverse environmental and amenity impacts it is recommended that Council approve the development, subject to conditions.