CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting,...

56
30

Transcript of CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting,...

Page 1: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

Products Services Applications

YEARS OF

QUALITY

M O R E

T H A N 30

CETA Testsysteme GmbH

Your Solution Partner for Industrial Leak Testing and Flow Measurement

Page 2: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

2

Contents

03 General information

08 Test devices and test systems

36 Accessories

48 Services

General information03 Company

04 Test parts

06 Test modes and typical applications

07 Typical Applications

Test devices and test systems08 CETATEST XS - Leak tester with gauge pressure sensor Compact, innovative, cost-e�ective

10 CETATEST 515 - Leak tester with di�erential pressure sensor Optimised for the test of small test parts with high cycle rate

12 CETATEST 715 - Leak tester with gauge pressure sensor Ideally suitable for test parts with large leaks

14 CETATEST 715 Twin - Leak tester with two gauge pressure sensors Parallel testing of two test parts with the same settings

16 CETATEST 815 - Leak tester with di�erential pressure sensors Test device which can be equipped with a lot of test options

18 CETATEST 815 Twin - Leak tester with di�erential pressure sensor For the synchronous two-channel operation

20 CETATEST 815 HP-PR - High pressure leak tester according to the pressure rise method Suitable for leak tests up to 400 bar

22 CETATEST 825 - New generation of leak testers with di�erential pressure sensor Successor of the CETATEST 815 devices

24 Hydrogen Leak Tester Gas-based leak testing down to leak rates of 10-6 mbar • l/s

26 CETATEST 615 - Mass �ow tester Detection of small leaks in large volume test parts

28 CETATEST 915 - Flow tester Flow detection by measuring the pressure decrease at a laminar �ow element (LFE)

30 CETATEST 915-G - Flow tester Especially for leak tests in the gas industry

32 CETA DVPG / 3K - Pressure progress test device Leak testing of the pneumatical circuits of motor vehicles

34 CETA Leak test systems

Semi-automatic test systems in modular design

Accessories36 CETA Soft application software

38 CETA standard leak

40 CETA master jet

42 CETA 2/2-way valve

44 CETA 3/2-way valve

46 CETA �lter combination

Services48 CETA service

50 DAkkS calibration laboratory and factory laboratory

52 International cooperation partners

NEW!

Page 3: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

3

„Your partner for more security in production“

Since more than 30 years CETA Testsysteme GmbH (located in Hilden nearby Duesseldorf ) has been producing physical test devices for the measurement of leaks and �ow rates. Throughout the world several thousand CETA test devices are already in use. These test devices are integrated in many industrial applications, mainly for quality control within the manufacturing process in fully automatic production lines. As test medium we use compressed air and hydrogen (forming gas). Based on continuous product improvement and development of new solutions we present us as a quali�ed and competent partner for the industry.

Partner of industry

Wide range of services

CETA o�ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation, maintenance, calibration, repair, alteration and maintenance contracts.

We carry out following calibrations:DAkkS calibrations for the measurand pressure (in the permanent laboratory and on-site)Factory calibrations for the messurand pressure and �owThe close cooperation between sales and service guarantees optimal customer care.

Company

Our certi�cations

Our customers

Our customers are mainly from the following branches: automotive industry, medical technology, �ttings industry, household appliances industry, packaging industry and E-mobility.

Manifold programm of test devices

We o�er leak detectors, �ow testers, mass �ow testers and the appropriate accessories. Therefore CETA is able to work out the best solution for the industrial test application in the area of leak and �ow testing. Due to di�erent test device technologies and a wide scope of pressure and measurement ranges nearly every test requirement can be ful�lled. An integrated control of the correct test device function guarantees a high standard of process reliability.

Quality award NRW 2002 Long-time excellent credit rating Member of the German Electrical andElectronic Manufacturers‘ Association (ZVEI) Member of the DGZfP - German Society for Non-Destructive Testing e. V.Member of the sponsoring companyKunststo�nstitut Lüdenscheid

DIN ISO 9001DAkkS calibration laboratory for the measurand pressure (DIN EN ISO IEC 17025)Patent for automatic function control (patent number 100 45 472)WEEE-Reg.-No. DE 61168724Science friendly companyConformance to the certi�cation requirements of well-known industrial customers

Page 4: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

4

Test Parts

Automotive industry

Climate industry

Electromobility

Electronics industry

Fittings industry

Household appliances industry

Medical technology

Packaging industry

Valves

FilterFuel lines Gas pressure springGearsHalogen lightsHeadlampsHeating regulatorsIndicatorsInjectorsInjection valvesLambda probesLampsLightsPipesPistonsPneumatic seat controls Pneumatic valvesPower steering systems Pre-burning chambers Pressure regulatorsPumpsRe�ectors RelaysSealing capsSensors Servo steeringsSilencersSucking jet pumpsSwitches TanksTire valves ValvesWindow liftsWiper motors

Automotive industry ABS sensorsABS valves Aerosol pumps Air bag activators Aluminium housings Antenna motors Anti-skid valves ASR-valves (Anti Slip Regulation)Batteries Belt tighteners Brake cylinders Brake lines Carburettors CastingsCatalytic convertersCatalystsCentral locking systemsCompensator reservoirs for brakesand coolers Compensators Connectors Cooler caps Cooler tubes Coolers Cylinder heads Clutch transducersDelivery pumps Diesel injection systems Door closers Drives Electronic control unit Engine blocksExhaust manifoldExhaust systems

Page 5: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

5

Climate industryCoolersCooler tubesHeat exchangersPipesSucking jet pumps

Electromobility (E-Mobility)Electric axle drive (eAxle)Displays for E-Bikes

Electronics industryCameras Connectors Electronic componentsHalogen lights Microswitches Photoelectric barriers RelaisSwitches

Fittings industryAluminium housingsBall valvesBuilt-in �ttingsCapsCastings Concealed �ttingsFittingsFlow heatersGas �ttingsGas heating systems Gas pressure springs Gas pressure regulators Gas ranges PipesSanitary armatures

Solder jointsThermostatesToilet �ushingsValvesValve seats

Household appliances industryBeverage containers Calori�ers Clocks Co�ee machinesConnectorsDoor closer delays Electric toothbrushes Electric razorsFire extinguishersFlow heaters Halogen lampsHot water boilersHousings for remote control unitsInk cartridgesLamps Light barriers LightersPlastic closuresPlastic seals Steam irons Storage water heaters Text markers Thermometers Thermos �asks Thermostats Water picks

Medical technologyBipolar forceps with double irrigationBlood bags

Test Parts

04

CathetersClosure systemsCuvettesDialysis accessoriesDisposable �nger cu�Endoscopy ForcepsInsulin pumpsIntracranial pressure probesInfusion equipmentsPackaging of pen needlesPlastic valvesPipettes Specimen testSyringesTransfer DeviceValves for dialysis machines

Packaging industryDrinking pouchBags for concentratesIntermediate Bulk Container (IBC)Drums

ValvesHydraulic valves Pneumatic valvesMagnetic valvesNon-return valvesOverpressure valves Solenoid valves Toilet �ashing valvesValve seats

Page 6: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

6

Test medium compressed air

Test medium forming gas

Typical applications

Test modes and applications Test medium compressed air The inexpensive and easily available test medium compressed air can be used for a wide range of industrial leak tests. Leak rates down to 10-3 mbar • l/s can be detected.

Test medium forming gasWith the test medium forming gas (5 % hydrogen, 95 % nitrogen) you can detect leak rates down to 10-6 mbar • l/s.

Test modes Typical applicationsPressure decay Leak tightness of �llable test partsPressure rise Leak tightness of combined chambersDynamic pressure Continuity testPressure steps/pressure ramps Opening and closing point of valvesClosed component Leak tightness of capsuled test partsVolume measurement Determination of test part volumesMass �ow Leak tightness of test parts with big volume and small leakageFlow test Determination of �ow through membranes, pipes, valves

Typical applicationsLeak test • Testing for oil- or water tightness • Leak testing according to the

requirements of the IP protection classes

• Testing of enclosures, gear box covers, reservoirs, shiners

• Testing of coolers, gear boxes, valves (internal and outer leak tightness)

Test modes and applications

• Leak testing of parts with venting elements (e.g. membranes)

• Testing of sensors, clocks, micro electronic devices (closed components)

• Testing of elements with hydraulics (e.g. servo pumps, power steering pumps, shock absorbers)

Test Modes and Typical Applications

Flow test• Continuity test of pipes and valves • Determination of the opening and

closing point of valves

• Flow test of tubes, coolant passages, valves, membranes, exhaust-gas systems

Page 7: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

7

Typical Applications

Method Test Parts

Leak Testing

Flow Measurement

Method Test Parts

Flow test Coolant passages, membranes, exhaust-gas-systems, pressure compensation elements, valves, tubes

Mass �ow test Large volume test parts with small leak rates

Continuity test Pipes, valves, openings

Dimensional accuracy Cross section of tubes and pipes

Pneumatic Controls

Existence test

Pressure test

Functional test

Volume determination

Assembly control

Pneumatic tests, multiple pressurisation Opening points, closing points

Adaption control, error prevention („poka yoke“)

Method Application

Direct �llable test parts Capsuled test parts Inner and outer leak tightness

Pressure rise

Gear box covers, reservoirs, headlamps

Micro electronic devices, sensors, clocks, lamps

Coolers, gear boxes, ball valves

Valves, coolers, heat exchangers

Page 8: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

8

Leak Tester CETATEST XS - compact, fast, cost-e�ective

The CETATEST XS is a compact, fully automatic leak tester for the detection of untight parts within the cycle time of the production process . The tester is designed for leak testing of small-volume test parts and short total testing times. It is equipped with a gauge pressure sensor, through which the leak-related pressure decay is detected during the measurement time (relative pressure method). Using the application software CETA Soft XS the parameterisation of the test programs is carried out. Measurement results and pressure variation curves can be recorded.

Operating methodsOne-channel operation

Signal processing24-bit-A/D-Converter

Valve typeMulti-function block Pressure sensorGauge pressure sensor

Measurement ranges± 2,500 Pa; ± 9,999 Pa / ± 25.0 hPa; ± 99.9 hPa (depending on the pressure range)

Result unitsPa, hPa (pressure decay)bar (test pressure)

Pressure rangesInternal electronically regulated: -1 bar/+1 bar; 0.010 - 0.200 bar; 0.020 - 1.000 bar; 0.20 - 8.00 bar (external pressure regulation as option)

Test modesPressure decay

Test optionsSmooth �lling (pressure ramp), pre�lling, preventing

Programmable test phasesDelay, �lling, stabilizing, measuring, venting, application-speci�c con�gurable, adjustable in 0.01 s-steps

Test mode speci�c limitsFill pressure, test part speci�c reject and rework levels

HandlingDigital I/O or by PC software, remote control (optional)

Parameter memory8 test programs, parameterising via CETA PC software

Languages PC softwareGerman, English, Spanish, French, Turkish, Hungarian, Vietnamese, Czech

Result memoryInternal ring memory (20,000 results)

XS

Page 9: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

9

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Power supply and power consumptionTest device: 24 VDC, max. 20 W External power supply: Input 100-240 VAC/47-63 Hz/1.62-0.72 A Output 24 VDC, max. 2.62 A

Compressed air supply At least 2 bar resp. 1 bar above test pressure, maximum 9.5 bar + 0.5 bar resp. 50 mbar under evacuation pressure (ISO 8573-1:2010 [1:4:1])

Pneumatic connections Input (compressed air supply): 6 x 1 mm �tting Port for test part: 6 x 1 mm �tting (depending on application)

DimensionsW x H x D : 280 mm x 96 mm x 250 mm

WeightApprox. 4.5 kg incl. external power supply

Scope of delivery External power supply, USB-cable, documentation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), 6/4 PA tube, spare sealing caps and spare union nuts

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST XS devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty 3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional) Remote control, standard leak, result label printer, �lter combination, more in the CETA accessories catalogue

Interfaces

Function Start / Stop Program selection

Device status system fault

Evaluation (Pass / Fail)

Measurement results

Parameter output

Parameterisation

Digital I/O (standard)

RS-232 (ASCII) *

USB-Slave (with CETA PC-Software)

**

* for each result **retrievable

Parameterisation of programs Visualisation pressure curveParameterisation of programs Visualisation pressure curve

Application software CETA Soft XS

XS

Page 10: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

10

Leak Tester CETATEST 515 - available in three di�erent types

The CETATEST 515 with di�erential pressure sensor is a full automatically working leak tester for the detection of untight parts within the cycle time of the production process. The leak tester is available in three di�erent types:

The con�guration “closed components - high resolution” can be used for test parts which cannot be �lled, so called “closed components”. It is possible to detect very small ratios of test part volumes (0.03 ml < ∆V < 1.0 ml).

The type “pressure decay - high speed” can be used for leak tests of very small test parts in high speed production cycles.

The con�guration “pressure rise” has a 50 % larger measurement signal (compared to the CETATEST 815).

Result unitsPa, hPa, PSI, Pa/s, hPa/s, mbar*l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure ranges-1 bar, 200 mbar, 1 bar, 6 bar, negative and positive gauge pressure ranges can be combined (e.g. -1 bar/+1 bar), other pressure ranges and mechanical pressure regulator on request

Test modesPressure decay, “closed component – high resolution”, pressure decay - “high speed”, pressure rise

Test optionsPre�ll, program series, smooth �lling, repeated �lling, temperature compensation, variable zero point, test repetition / automatic test time adjustment, free programmable control valves

Operating methodsOne channel operation

Signal processingFast 24-bit-A/D-ConverterReal-time processing of the measurement signals

PneumaticMinimized volume to optimise the resolution ProcessingReal time microcontroller system, 16-bit µC / 40 MHz

Pressure sensorsDi�erential pressure sensor, gauge pressure sensor

Measurement ranges± 500 Pa / ± 5,000 Pa (displayed resolution: 1 Pa, internal resolution: e�ective 0.01 Pa), other ranges on request

System controlStill-Alive-Check with di�erential pressure sensor control, patented automatic function control (option), control of the compressed air supply, consecutive zero results.

Programmable test phasesDelay, �lling, stabilising, measuring, venting, reservoir �lling, �ooding, re�lling

Test mode speci�c limitsPre�ll pressure, �lling pressure, test part speci�c reject and rework levels

HandlingIntuitive menu, password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

1

2

3

515

Application SoftwareCETA Soft 2G for free!

Page 11: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

11

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester 515

Interfaces

Further interfaces on request. The optional RS-232 protocol converter enables the exchange of a CETATEST 510 that communicates via RS-232, against a CETATEST 515.

Function Start / Stop / Reset

Program selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Further functions Result statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply and power consumption100 - 240 V AC, 47 – 63 Hz, 0.6 - 0.3 A, depending on stage of expansion max. 60 W

Compressed air supply 6 - 10 bar and 0.5 bar above test pressure resp. 50 mbar under evacuation pressure (ISO 8573-1:2010 [1:4:1])

Pneumatic connections Input (compressed air supply): 6 mm plug-in �tting

Port for test part: 3 mm clamping ring Up to three pneumatically controlled outputs

Dimensions and weightW x H x D: 345 mm x 145 mm(3 U) x 435 mm Weight: ca. 10 kg

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST 515 devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty 3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional) Filter combination, leak test, leaktight 3/2-way valve, RS-232 protocoll converter, application software CETA Soft 2G, scanner interface, more in the CETA accessories catalogue.

Negative gauge pressure input (option)

Digital signal outputs

Reference output

Digital signal inputs

RS-232 interface p1

Controlled pressure output (option)

Test output

Vent portp2

Compressed air inputInterface for future extensions

Main switch

Voltage supply

Optional interfaces

Page 12: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

12

715

Operating methodsOne channel operation

Signal processing Fast 24-bit-A/D-Converter Real-time processing of the measurement signals

Valve types Sliding valve or poppet valve

ProcessingReal time microcontroller system, 16-bit µC / 40 MHz

Pressure sensorGauge pressure sensor

Measurement rangesMax. +/-10,000 Pa, depending on the pressure range (resolution: 1 Pa), other ranges on request

Result unitsPa, hPa, PSI, Pa/s, hPa/s, mbar*l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure ranges-1 bar, 200 mbar, 1 bar, 6 bar, 10 bar, 16 bar, 20 bar, negative gauge pressure and positive gauge pressure ranges can be combined, (e.g. -1 bar/+1 bar), other pressure ranges and mechanical pressure regulator on request

Test modesPressure decayOptional: dynamic pressure, test of sealed components

Test options Test repetition / automatic test time adjustment, pre�ll (incl. repeated �lling), program series, smooth �lling, variable zero point, free programmable control valves

Leak Tester CETATEST 715 The CETATEST 715 is a fully automatic working leak tester for the detection of untight parts within the cycle time of the production process. The leak tester uses a gauge pressure sensor and has a large measurement range. Therefore the CETATEST 715 is especially quali�ed for the simple testing of parts with large leakages.

System control Supply pressure monitoring, consecutive zero results

Programmable test phases Reservoir �lling, �ooding, re�lling, delay, �lling, stabilising, measuring, venting

Test mode speci�c limits Pre�ll pressure, �lling pressure, test part speci�c reject and rework levels

HandlingIntuitive menu including password protected user levels

Parameter memory 64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

Application SoftwareCETA Soft 2G for free!

Page 13: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

13

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Further functions Result statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply and power consumption 100 - 240 V AC, 47 – 63 Hz, 0.6 - 0.3 A, depending on stage of expansion max. 60 W

Compressed air supply 6 - 10 bar and 0.5 bar above test pressure resp. 50 mbar under evacuation pressure (ISO 8573-1:2010 [1:4:1]). Test devices with pressure ranges higher than10 bar have an additional connection for the external compressed air >10 bar.

Further interfaces on request. The optional RS-232 protocol converter enables the exchange of a CETATEST 710, that communicates via RS-232, against a CETATEST 715.

Pneumatic connectionsInput (compressed air supply): 6 mm plug-in �tting Port for test part: 6 x 1 mm �tting, 6 mm clamping ring (option)Up to three pneumatically driven outputs (option)

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight: Appr. 10 kg

Scope of delivery Special packaging, power cord, documen-tation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST 715 devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories optionalFilter combination, standard leak, leaktight 3/2-way valve, Twin tube, RS-232 protocoll converter, RS-232/Ethernet adapter, application software CETA Soft 2G, scanner interface, more in the CETA accessories catalogue.

Interfaces

Function Start / Stop / Reset

Program selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

715

Digital signal outputs

Digital signal inputs

Controlled pressure output (option)

Test output

Compressed air input

Interface for future extensions

RS-232 interface

Main switch

Voltage supply

Optional additional test pressure input (apply to > 10 bar)

Negative gauge pressure input (option)

p1

Vent port

Optional interfaces

Page 14: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

14

715 Twin

Operating methodsTwo channel operation Synchronous two channel operation, single channel mode possible

Signal processing Fast 24-bit-A/D-Converter Real-time processing of the measurement signals

Valve types Poppet valve

ProcessingReal time microcontroller system, 16-bit µC / 40 MHz

Pressure sensorsTwo gauge pressure sensors

Measurement rangesMax. +/-10,000 Pa, depending on the pressure range (resolution: 1 Pa), other ranges on request

Result unitsPa, hPa, PSI, Pa/s, hPa/s, mbar*l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure ranges-1 bar, 200 mbar, 1 bar, 6 bar, 10 bar, negative gauge pressure and positive gauge pressure ranges can be combined, (e.g. -1 bar/+1 bar), other pressure ranges and mechanical pressure regulator on request

Test modesPressure decay measurement

Test options Pre�ll (incl. repeated �lling), smooth �lling, variable zero point, free programmable control valves

System control Supply pressure monitoring, consecutive zero results

Leak Tester CETATEST 715 Twin The CETATEST 715 Twin is a fully automatic working leak tester for the detection of untight parts within the cycle time of the production process. The leak tester uses two gauge pressure sensors and has a large measurement range. Therefore the CETATEST 715 Twin is especially quali�ed for the simple testing of parts with large leakages. The di�erential pressure leak tester is designed for synchronous two-channel operation and is suitable for applications in which test parts can be tested with the same settings. The channel speci�c adjustment of the leak thresholds is possible.

Programmable test phases Delay, �lling, stabilising, measuring, venting

Test mode speci�c limits Pre�ll pressure, �lling pressure, test part speci�c reject and rework levels

HandlingIntuitive menu including password protected user levels

Parameter memory 64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

Application SoftwareCETA Soft 2G for free!

Page 15: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

15

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Optional additional test pressure input (apply to > 10 bar)

Negative gauge pressure input (option)

Optional interfaces

Further functions Result statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply and power consumption 100 - 240 V AC, 47 – 63 Hz, 0.6 - 0.3 A, depending on stage of expansion max. 60 W

Compressed air supply 6 - 10 bar and 0.5 bar above test pressure resp. 50 mbar under evacuation pressure (ISO 8573-1:2010 [1:4:1]). Test devices with pressure ranges higher than10 bar have an additional connection for the external compressed air >10 bar.

Further interfaces on request.

Pneumatic connectionsInput (compressed air supply): 6 mm plug-in �tting Port for test part: 6 x 1 mm �tting, 6 mm clamping ring (option)Up to three pneumatically driven outputs (option)

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight: Appr. 11 kg

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST 715 Twin devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories optionalFilter combination, standard leak, leaktight 3/2-way valve, Twin tube, RS-232 protocoll converter, RS-232/Ethernet adapter, application software CETA Soft 2G (limited scope of services), scanner interface, more in the CETA accessories catalogue.

Interfaces

Function Start / Stop / Reset

Program selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

715 Twin

Digital signal outputs

Digital signal inputs

Controlled pressure output (option)

Vent port

Compressed air input

Interface for future extensions

RS-232 interface

Main switch

Voltage supplyTest output 1

Test output 2

Page 16: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

16

Leak Tester CETATEST 815 - makes precision work

The CETATEST 815 is a fully automatic working leak tester for the detection of untight parts within the cycle time of the production process. The pressure in the test part volume due to a leakage is compared with the pressure in a tight reference volume (di�erential pressure method).

Operating methodsOne channel operation

Signal processing Fast 24-bit-A/D-Converter Real-time processing of the measurement signals

Valve types Depending on the application: sliding valve or poppet valve

ProcessingReal time microcontroller system, 16-bit µC / 40 MHz

Pressure sensorsDi�erential pressure sensor gauge pressure sensor

Measurement ranges ± 500 Pa / ± 5,000 Pa (displayed resolution: 1 Pa, internal resolution: e�ective 0.01 Pa), other ranges on request

Result units Pa, hPa, PSI, Pa/s, hPa/s, mbar*l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure ranges-1 bar, +/-5 mbar, +/-50 mbar, 200 mbar, 1 bar, 6 bar, 10 bar, 20 bar, 30 bar, negative gauge pressure and positive gauge pressure ranges can be combined, (e.g. -1 bar/ +1 bar), other pressure ranges and mechanical pressure regulator on request

Test modesPressure decay Optional: sealed component, dynamic pressure, pressure steps, pressure rise (with double leak connector)

Test options Pre�ll (multiple �lling), program series, smooth �lling, repeated �lling, temperature compensation, variable zero point, test repetition / automatic test time adjustment, free programmable control valves

System control Still-Alive-Check with di�erential pressure sensor control, patented automatic function control (option), control of the compressed air supply, consecutive zero results

Programmable test phases Delay, pre�lling, preventing, �lling, stabilising, measuring, venting, reservoir �lling, �ood, re�lling

Test mode speci�c limitsPre�ll pressure, �lling pressure, test part speci�c reject and rework levels

HandlingIntuitive menu including password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

815

Application SoftwareCETA Soft 2G for free!

Page 17: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

17

815

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Interfaces

Further interfaces on request The optional RS-232 protocol converter enables the exchange of a CETATEST 810 that communicates via RS-232, against a CETATEST 815.

Function Start / Stop / Reset

Program selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Further functions Result statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply / Power consumption 100 - 240 V AC, 47 – 63 Hz, 0.6 - 0.3 A, depending on stage of expansion max. 60 W

Compressed air supply 6 - 10 bar and 0.5 bar above test pressure resp. 50 mbar under evacuation pressure (ISO 8573-1:2010 [1:4:1]). Test devices with pressure ranges higher than10 bar have an additional connection for the external compressed air >10 bar.

Pneumatic connections Input (compressed air supply): 6 mm plug-in �tting Port for test part: 6 x 1 mm �tting, 6 mm clamping ring (option),up to three pneumatically driven outputs (option)

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight: appr. 10 kg

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST 815 devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional) Filter combination, standard leak, leaktight 3/2-way valve, RS-232 protocoll converter, RS-232/Ethernet adapter, application software CETA Soft 2G, scanner interface, more in the CETA accessories catalogue.

Digital signal outputs

Digital signal inputs Compressed air input

Optional additional test pressure input (apply to > 10 bar) Negative gauge pressure input (option) or

primary pressure output (pressure rise)

RS-232 interface

p1

Controlled pressure output (option)

Test output

Reference output

Vent port

Interface for future extensions

Main switch

Voltage supply

Optional interfaces

Page 18: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

18

Leak Tester CETATEST 815 Twin - parallel testing

The di�erential pressure leak tester CETATEST 815 Twin is designed for synchronous two-channel operation and is suitable for applications in which test parts can be tested with the same settings. The channel speci�c adjustment of the leak thresholds is possible. The di�erential pressure method compares the pressure decay in the test part volumes due to leakages with the pressures in the reference volumes.

Operating methodsSynchronous two channel operation, single channel mode possible

Signal processingFast 24-bit-A/D-ConverterReal-time processing of the measurement signals

Valve typesSeat valvel

ProcessingReal time microcontroller system, 16-bit μC / 40 MHz Pressure sensorOne gauge pressure sensor Each channel one di�erential pressure sensor

Measurement ranges± 500 Pa / ± 5.000 Pa (displayed resolution: 1 Pa, iinternal resolution: e�ective 0.01 Pa) other ranges on request

Result units

Pa, hPa, PSI, Pa/s, hPa/s, mbar*l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure ranges-1 bar, 200 mbar, 1 bar, 6 bar, 10 bar,negative gauge pressure and positive gauge pressure ranges can be combined (f.e. -1 bar/+1 bar), other pressure ranges on request

Test modes / test optionsPressure loss, Pre�ll, Smooth �lling, Analysis of the �lling and stabilizingcurve, Repeated measurements / Automatic measuring time adjustment, free programmable control valves

System controlControl of the compressed air supply, in the case of test cycle interruption in one channel (e.g. due to a gross leak) the test cycle in the other channel continues, Still-Alive-Check with di�erential pressure sensor control

Programmable test phases Delay, pre�lling, preventing, �lling, stabilising, measuring, venting, reservoir �lling, �ood, re�lling

Test mode speci�c limitsPre�ll pressure, �lling pressure, test mode speci�c reject and rework levels

HandlingIntuitive menu including password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

815 Twin

Application SoftwareCETA Soft 2G for free!

Page 19: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

19

815 Twin

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Interfaces

Further interfaces on request.

Function Start / Stop / Reset

Programm- selection

Device status / system fault

Evaluation (Pass /Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Digital signal outputs

Reference output 1

Controlled pressure output 2 (option)

Compressed air input

Negative gauge pressure input (option)

RS-232 interface

Interface for future extensions

Main switch

Voltage supplyControlled pressure output 1 (option)

Reference output 2

Optional interfaces

Test output 2

Vent port

Test output 1

Digital signal inputs

Further functionsResult statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply and power consumption100 – 240 V AC, 47 – 63 Hz, 0.6 – 0.3 A, depending on stage of expansion max. 60 W

Compressed air supply6 - 10 bar and 0.5 bar above test pressure resp. 50 mbar under evacuation pressure (ISO 8573-1:2010 [1:4:1]).

Pneumatic connections Input (compressed air supply): 6 mm plug-in �tting Port for test part: 6 x 1 mm �tting, 6 mm clamping ring (option)Up to two pneumatically driven outputs (option)

Dimensions and weightW x H x D: 345 mm x 145 mm (3U) x 435 mm Weight: appr. 11kg

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST 815 Twin devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional) Filter combination, standard leak, leak tight 3/2-way valve, RS-232 / Ethernet-adapter, application software CETA Soft 2G (limited scope of services), scanner interface, more in the CETA accessories catalogue.

Page 20: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

20

Leak tester CETATEST 815 HP-PR - testing with high pressure

The CETATEST 815 HP-PR in the variant high pressure can be used for leak tests (e.g. injection valves) up to a test pressure of 400 bar using the test mode pressure rise. Hereby the primary circuit is pressurised with the test pressure (up to 400 bar). The leakage test is performed in the secondary circuit.

Operating methodsTwo channel operation optional

Signal processing Fast 24-bit-A/D-Converter Real-time processing of the measurement signals

Valve type Poppet valve (primary circuit), sliding valve (secondary circuit)

Sequence controllerMicrocontroller system Pressure sensorsPiezo-resistive di�erential pressure transducer (in secondary circuit), Piezo-resistive gauge pressure sensor (in primary and secondary circuit)

815 HP-PR

Measurement rangeDi�erential pressure sensor: ± 500 Pa / ± 5.000 Pa (displayed resolution: 1 Pa, internal resolution: e�ective 0.01 Pa) other ranges on request

Result unitsPa, hPa, PSI, Pa/s, hPa/s, mbar*l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure rangesPrimary pressure: to 400 barSecondary pressure: to 150 mbar, other pressure ranges on request

Test modes Pressure rise

Control systems Still-Alive-Check with control of the di�erential pressure sensor, over�ow valves, consecutive zero results

Programmable test parameterPrimary- and secondary pressure circuit: target pressures, pressure limit value, delay time, �ll time, stabilization time, measurement time, dp-limit value, exhaust time, reject level, rework level

Test mode speci�c limitsPre�ll pressure, �lling pressure, test mode speci�c reject and rework levels

HandlingIntuitive menu including password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

Application SoftwareCETA Soft 2G for free!

Page 21: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

21

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester 815 HP-PR

Interfaces

Further interfaces on request.

Function Start / Stop / Reset

Programm selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Further functionsResult statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply and power consumption100 – 240 V AC, 47 – 63 Hz, 0.6 – 0.3 A, depending on stage of expansion, max. 60 W (for each CETATEST 815)

Compressed air supply 6 - 10 bar and 0.5 bar above test pressure (ISO 8573-1:2010 [1:4:1]), High pressure input up to 450 bar

Pneumatic connectionInput (compressed air supply): 6 mm plug-in �tting , primary circuit: 6 mm clamping ringsecundary circuit: 3 mm clamping ring

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight approx. 23 kg (for one channel version), approx. 33 kg (for two channel version)

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, DAkkS calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

DAkkS calibration and DAkkS calibration certi�cateAll new CETATEST 815 HP-PR devices up to 60 bar pressure range will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional) Filter combination, standard leak, leak tight 3/2-way valve, RS-232 / Ethernet adapter, application software CETA Soft 2G, more in the CETA accessories catalogue.

Test output test part 1

Test output test part 2 (option) Test output control device 2 (option)

Vent port

Test pressure output

High pressure input

Test output control device 1

Vent port

Compressed air inputp1

Reference output

Test output

Digital signal outputs

Interface for future extensions

Digital signal inputs

Main switch

Optional interfaces

RS-232 interface

Connection to control device

Page 22: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

22

System architectureIndustrial PC: Quad Core CPU, 1.8 GHz,4 GB RAM, 128 GB SSD,Micro-controller system for the test process control: 32-bit ARM μC / 84 MHz

Signal processingFast 24-bit A/D converter, real-time processing of measurement signals

Valve typesSliding valve or poppet valve(depending on the application)

System featuresFlow-optimized pneumaticsLow inherent volume of the measuring circuitIntegrated security functionsFlexible con�guration of test phasesExternal sensors can be integrated

Pressure sensorsGauge pressure sensorDi�erential pressure sensor

Measurement ranges± 500 Pa / ± 5,000 Pa (display resolution: 1 Pa, internal resolution: e�ectively 0.01 Pa), other ranges on request

Result unitsPa, hPa, PSI, Pa/s, hPa/s, mbar • l/s, ml/min, ml/h, l/min, l/h, mmHg, mmWs, Torr

Pressure ranges-1 bar, +/- 5 mbar, +/- 50 mbar, 200 mbar, 1 bar, 6 bar, 10 bar, 20 bar, 30 barnegative and positive gauge pressure ranges can be combined (for example -1 bar/+10 bar), other pressure ranges on request

Test modesPressure decayOptional: sealed component, dynamic pressure, pressure steps, pressure rise

Optional additional functionsPre�ll, program series, smooth �lling, pulsing, temperature compensation, variable zero point, test repetition, automatic test time adjustment, freely programmable control valves

OperationTouch screen, dual jog dial,separate start / stop buttons,password protected user levels,CETA app for tablets / smartphones

Display7-inch color screen,various graphical diagrams (measurement curves, histogram, measurement series overview), list of results

System monitoringSelf-tightness test, logging of valve switching times, Still-Alive-Check with di�erential pressure sensor monitoring,patented, automatic function control (option), control of the compressed air supply, consecutive zero results

MemoryFor more than 1 million measurement results, 256 individually parameterizable test programs with alpha-numeric program names, export / import of test programs via device interfaces or by usage of a USB storage device

825

CETATEST 825 - New generation of innovative leak testers with di�erential pressure sensor

The CETATEST 825 is the fourth generation of CETA di�erential pressure testers, as a variant of the new series of test devices CETATEST x25. Following the x15 series, known for the quality, reliability and durability of its devices, the new x25 series features a large number of technical innovations.

NEW

Page 23: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

23

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

InterfacesI/O interface for start/stop/reset, program selection, device status, system faults and test results (pass/fail).RS-232, USB (host), Ethernet, WLAN, Bluetooth for additional functions parameterization, measurement results, detailed information in real time (e. g. measurement curve) and failure messages.

An optional Anybus module can be used to implement additional interfaces such as Pro�bus DP, Pro�net, EtherCAT or USB (Slave).

The CETATEST 825 is fully interface compatible with the CETATEST 815 and well prepared for Industry 4.0 requirements.

Further functionsResult statistics, cycle counter, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming, integration of test part image / barcode / QR code, user administration, export of test parameters, measurement curves and measurement series to USB storage media, nominal pressure optimization

User supportAutomatic parameter determinationLeak rate set-up wizardTeach-in modeMaintenance monitoringOverview of parameter changes

Supply voltageTest device: 24 VDCExternal power supply:Input 100-240 VAC/47-63 HzOutput 24 VDC

Air supply6 - 10 bar, min. 0.5 bar above test pressure resp. 50 mbar below evacuation pressureTest devices with pressure ranges higher than 10 bar have an additional connection for the external compressed air > 10 bar.Quality or purity according to ISO 8573-1: 2010 [1: 4: 1]

Pneumatic connectionsInput (compressed air supply):6 mm plug-in �ttingPort for test part: 6 x 1 mm �tting,6 mm clamping ring (option),up to three pneumatically driven outputs (option)

DAkkS calibration and DAkkS certi�cateAll new devices will be delivered free of charge with DAkkS calibration certi�cate according to DIN EN ISO/IEC 17025.

Dimensions and weightW x H x D: 367 mm x 183 mm (4 U) x 435 mm Weight: approx. 10 kg

Scope of deliverySpecial packaging, power supply, power cord, documentation on CD, DAkkS calibration certi�cate,EU declaration of conformity,D-Sub-plug, digital input and output cable, spare sealing caps and spare caps for union nuts coupling or spare clamp rings

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional)Filter combination, test leak, leaktight 3/2-way valve, RS-232 protocol converter, application software CETA Soft 2G available on request free of charge, scanner interface, remote control panel, further accessories in the CETA accessories catalogue

825

Option: Negative gauge pressure input

Optional Anybus module for additional interfaces such as Pro�bus DP, Pro�net, EtherCAT or USB (Slave)

Digital signal inputs

RS-232 interface

USB Host

Digital signal outputs

Ethernet

Interface for optional extensions

Option: Controlled pressure output

Reference output Test outputVent port

Additional test pressure input (apply to > 10 bar)

Compressed air input

24 VDC input

Page 24: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST Leak Tester

24

The Hydrogen Leak Tester for leak rates down to 10-6 mbar . l/s The Hydrogen Leak Tester is a modular system for leak testing of gas-�lled or liquid-�lled product packaging and molded components and parts. The system’s patented and highly sensitive operating method is based on the detection of gases or vapors evaporating from such packaging or molded parts in case of leakage. If the packaging or molded parts do not already contain gases or vapors, tracer gases can be injected prior to leak testing. Typical test gases and test vapors are forming gas 95/5 (95% nitrogen and 5% hydrogen), alcohols, solvents and other volatile organic gas- and vapor mixtures. A multiphase test sequence with a reference phase, which suppresses ambient �uctuations, enables the detection of leaks up to 10-6 mbar • l/s.

1. The test medium escaping from a leak in the test part is accumulated in a closed test chamber.

2. The gas volume from the chamber passes the sensor and the resulting signal is measured.

Hydrogen Leak Tester

�lter

valve 1

valve 2

test chamber

sensor

pump

Accumulation

�lter

valve 1

valve 2

test chamber

sensor

pump

Injection

Highly sensitiveLow costFastPressurelessBroadband (for ingredients)Selective (for tracer gases)Modular

      

Page 25: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

25

Measuring method • Detection limit:

10-6 mbar . l/s (optimal con�guration)

• Automated test procedure

• Di�erent test methods

• Pressure at the test piece: approx. 1 bar

• Selective sampling (via pump)

• Flow rate: 1 - 3 l/min (optional: 180 - 700 ml/min)

• Detectable gases: all oxidisable and reducible gases

Power supply • 100 – 240 V / 50 – 60 Hz

Dimensions and weight• L x H x W:

465 mm x 198 mm x 315 mm

• Weight without test chamber: 9 - 12,5 kg

Con�guration• Sensors for pressure, �ow, humidity

(option)

• Operation of an external test chamber

• Control of sensors, valves, heating - additional external components on demand

• Touch screen operation

• USB port

Calibration unit Test leak with tracer gas

• Pressure on test leak : 0,9 - 7 bar

• Test leak incl. 3-point calibration

• Connection: pipe Ø 3 mm

I/O-unit• Ethernet (optional)

• Proprietary, extensible module interface (on demand)

• Pro�bus (optional)

• Additional interfaces (on demand)

Measuring unit• Number of gas sensors: 2

(depending on application)

• Sensors for pressure, �ow, humidity (optional)

• Connection: tube Ø 4 mm (other sizes on demand)

Purging unit Purging gas pressure up to 2 bar

• Connection: tube Ø 6 mm (other sizes on demand)

Filling unit• Evacuating DUT

• Filling DUT with test gas

• Purging DUT with compressed air

• Filling pressure: 0 – 8 bar

• Connection: pipe Ø 6 mm

Purging unit Calibration unit

I/O-unitMeasuring unit Filling unit

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Hydrogen Leak Tester Leak Tester

Page 26: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

26

Mass Flow Tester CETATEST 615 - for the leak test of large volume parts

The CETATEST 615 is a fully automated mass �ow tester for the detection of small leaks in large volume test parts. The measurement method is based on the principle of the thermal mass �ow measurement. By using a previously pressurised reservoir volume leakages can be measured without the disturbing e�ects of a pressure regulation. Temperature e�ects are automatically compensated. The mass �ow caused by the leakage is displayed directly for standard conditions, which can be parameterised.

Operating methodsOne channel operation

Signal processing Fast 24-bit-A/D-Converter Real-time processing of the measurement signals

ProcessingReal time microcontroller system, 16-bit µC / 40 MHz

Sensors Gauge pressure sensor Thermal mass �ow sensor

Measurement ranges 0 - 10 ml/min, 0 - 25 ml/min, 10 - 600 ml/min (displayed resolution: 0.01 ml/min), other ranges on request

Result units Nml/min, Nml/h, Nl/min, Nl/h, scc/min, scc/h, sl/min, sl/h, mbar*l/s

Pressure ranges200 mbar, 1 bar, 6 bar, 10 bar, other pressure ranges and mechanical pressure regulator on request

Test optionsProgram series

System control Control of the compressed air supply, consecutive zero results

Programmable test phases Delay, reservoir �lling, �ooding , �lling, stabilising, measuring, venting

Test mode speci�c limitsReservoir pressure, test pressure, test part speci�c reject and rework levels

HandlingIntuitive menu including password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

CETATEST 615 Mass Flow Tester

Application SoftwareCETA Soft 2G for free!

Page 27: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

27

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester CETATEST 615 Mass Flow Tester

Interfaces

Further interfaces on request.

Function Start / Stop / Reset

Program selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Further functions Result statistics, indicator for service intervals, registration of parameter change, recording of measurement series and measurement curves, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply / power consumption 100 - 240 V AC, 47 – 63 Hz, 0.6 - 0.3 A, depending on stage of expansion max. 60 W

Compressed air supply 6 - 10 bar and 0.5 bar above test pressure (ISO 8573-1:2010 [1:4:1]).

Pneumatic connections Input (compressed air supply): 6 mm plug-in �tting

Port for test part: 8 x 1 mm �tting Port for reservoir: 8 x 1 mm �tting Up to three pneumatically driven outputs (option)

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight: appr. 10 kg

Scope of delivery Special packaging, power cord, documentation on CD, calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional) Filter combination, standard leak, leaktight 3/2-way valve, RS-232/Ethernet adapter, application software CETA Soft 2G, scanner interface, more in the CETA accessories catalogue.

Digital signal outputs

Digital signal inputs Compressed air input

RS-232 interface

Test part

Interface for future extensions

Main switch

Voltage supply

Optional interfaces

Vent port

Reservoir volume

Controlled pressure output (option)

Page 28: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

28

Flow Tester CETATEST 915 - for volume �ow measurement The �ow tester CETATEST 915 is used to measure the �ow using compressed air. The device contains a measurement system consisting of a laminar �ow element (LFE) and a di�erential pressure sensor. In the direct test method the air,provided by the internal pressure regulator, �ows through the measuring section before it enters the test part. In the indirect test method the measuring section is located behind the test part. Due to the special design of the measuring section a laminar �ow is generated. The resulting pressure di�erence is directly proportional to the volume �ow. With the optional electronical pressure regulator and four calibrations for up to four test pressures the application range is substantially broadened.

Signal processingFast 24-bit-A/D-Converter

Sequence controllerReal time microcontroller system, 16-bit μC / 40 MHz

Pressure sensorsDi�erential pressure sensor, gauge pressure sensor (test pressure)

Pressure ranges-1,000 mbar, 150 mbar, 1,000 mbar, 6 bar, other pressure ranges and electronical pressure regulator on request

Result unitsml/min, ml/h, l/min, l/h, mbar*l/s

Test modes / test optionsDirect method, indirect method, exponential extrapolation, bypass

Test phasesDelay, �lling, stabilising, measuring, venting

RGK

RK

RM

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

8 x 1 mm �tting

10 x 1 mm �tting

10 x 1 mm �tting

10 x 1 mm �tting

10 x 1 mm �tting

Type of LFE Flow at positive gauge pressure Test connections of 50 mbar in the LFE

1

1

1

1

2

3

5

8

20

30

55

80

100

148

3 - 250 ml/min

4 - 310 ml/min

11 - 890 ml/min

60 - 2,450 ml/min

110 - 5.000 ml/min

175 - 7,500 ml/min

16 - 750 l/h

24 - 1,200 l/h

70 - 2,850 ml/min

130 - 4,650 l/h

3.5 - 140 l/min

5.8 - 200 l/min

7.5 - 200 l/min

10.2 - 200 l/min

Measurement ranges of the laminar �ow elements

CETATEST 915Flow Tester

Application SoftwareCETA Soft 2G for free!

Page 29: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

29

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester 915Flow Tester

Power supply and power consumption100 – 240 V AC, 47 – 63 Hz, 0,6 – 0,3 A, depending on stage of expansion max. 60 W

Compressed air supply1.0 bar above test pressure resp. 50 mbar under evacuation pressure(ISO 8573-1:2010 [1:4:1])

Pneumatic connectionsInput (compressed air supply): 6 mm plug-in �tting Port for test part: depending on the LFE used Pneumatically controlled and individually adaptable outputs (option)

Special calibration

Flow calibrations for up to four test pressures optional

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight: appr. 10kg

Further interfaces on request. The optional RS-232 protocol converter enables the exchange of a CETA 900 that communicates via RS-232, against a CETATEST 915.

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional)Filter combination, master jet, leak tight 3/2-way valve, RS-232 / Ethernet-adapter, control- and evaluation software, application software CETA Soft 2G, scanner interface, more in the CETA accessories catalogue

Test mode speci�c limitsFilling pressure, test part speci�c reject and rework levels

HandlingIntuitive menus, password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

Further functionsResult statistics, indicator for service intervals, recording of parameter change, recording of measurement curves and measurement series, Dynamic Link Library (DLL) for RS-232 interface programming

Digital signal outputs Compressed air input

RS-232 interface

Interface for future extensions

Main switch

Controlled pressure output (option)

Digital signal inputsTest output

Power supply

Optional interfaces

Option: bypass

Interfaces

Function Start / Stop / Reset

Programm selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Page 30: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

30

Flow Tester CETATEST 915-GThe CETATEST 915-G is a fully automatic �ow test device for the detection of untight parts. The test is automatically started after adaption of the test part. This method of operation has been developed especially for the gas industry and for reworking in the automobile industry. The pressure drop of the laminar �ow element (LFE) is measured by a di�erential pressure sensor and converted into a �ow value.

Operating methodsDirect laminar �ow measurement

Signal processingFast 24-bit-A/D-Converter Real time processing of the measurement signals

ProcessingReal time microcontroller system, 16-bit μC / 40 MHz

Start functionSelectable automatic start

Pressure sensorsDi�erential pressure sensor, gauge pressure sensor (test pressure)

Measurement ranges10 bis 600 ml/hother ranges on request

Result unitsml/min, ml/h, l/min, l/h, mbar*l/s

Pressure ranges150 mbar and 600 mbar(other pressures on request)

Test modes / test optionsLeak test on �ow basis, zero result measurements

Programmable test phasesDelay, �lling, stabilising, measuring

Adjustable threshold valuesFilling pressure, test part speci�c reject and rework levels

HandlingIntuitive menus, password protected user levels

Parameter memory64 individually parameterizable test programs with alpha-numeric program names, parameters of the test programs can be exported resp. imported via the test device interfaces or by usage of a USB storage device.

CETATEST 915-GFlow Tester

Application SoftwareCETA Soft 2G for free!

Page 31: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

31

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Further functionsResult statistics, indicator for service intervals, recording of parameter change, recording of measurement curves and measurement series, Dynamic Link Library (DLL) for RS-232 interface programming

Power supply and power consumption100 – 240 V AC, 47 – 63 Hz, 0.6 – 0.3 A je nach Ausbaustufe max. 60 W

Compressed air supply1.0 bar above test pressure

Pneumatic connectionsInput (compressed air supply): 6 mm plug-in �ttingPort for test part �tting for 6 x 1 mm

polyamide tubesThree pneumatically controlled and individually adaptable outputs (option)

Dimensions and weightW x H x D: 345 mm x 145 mm (3 U) x 435 mm Weight: appr. 10kg

Scope of delivery Special packaging, power cord, documentation and PC-software on CD, calibration certi�cate, EU declaration of conformity, D-Sub-plug including cable for inputs and outputs (PLC-communication), spare sealing caps and spare caps for union nuts coupling or spare clamp rings

Digital signal outputs

Compressed air inputInterface for

future extensions

Power supply

Controlled pressure output (option)

Digital signal inputs

Optional interfaces

Test output

Main switch

RS-232 interface

Warranty3 years in case of yearly maintenance, optional prolongation to 5 years

Accessories (optional)Filter combination, master jet, leak tight 3/2-way valve, RS-232 / Ethernet-adapter, control- and evaluation software, application software CETA Soft 2G, scanner interface, more in the CETA accessories catalogue

915-GFlow Tester

Further interfaces on request.

Interfaces

Function Start / Stop / Reset

Programm selection

Device status / system fault

Evaluation (Pass / Fail)

Parameterization Measurement results

Detailed fault messages

Digital I/O (standard)

RS-232 (standard)

Pro�bus DP (option)

Pro�net (option)

Ethernet (option)

EtherCAT (option)

Page 32: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

32

DVPG | 3KPressure Progress Test Device

Operating methodsThree channel operation

SystemμPC with Solid State Disk (SSD),16 bit A/D converter module

Display8-line display with 40 characters each, blue-white design

Pressure sensorsHigh precision gauge sensors 21 bar

Measuring range0.00 to 20.00 bar

Result unitbar

Rating indicationDisplay, LEDs

Test modesPressure di�erence

ParameterisationVia XML �le (generated with CETA XML editor)

Programmable test phases Stabilising, measuring

Pressure Progress Test Device DVPG / 3KThe compact, transportable Pressure Progress Test Device DVPG / 3K is designed for the leak testing of pneumatical circuits, which are pre-�lled up to the target pressure. Typical applications are vehicles for the transport of commercial goods and passengers. The integrated UPS allows a continuous operation of up to 8 hours. The tester is equipped with a specially designed holding device, which allows a problem-free attachment to the vehicle frame.

Page 33: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETATEST

33

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Leak Tester

Test mode speci�c limits (individual for each channel)Stabilising pressure tolerances,Di�erential pressure thresholds

OperationKeypad (20 keys), Stainless steel, IP 65

Parameter memory Individually parameterisable test programs with alphanumeric program names. Test programs can be exported and imported as an XML �le via the USB interface

Power supply Current consumption9 - 36 V DC, 6 A max., wrong polarity and short circuit protected, Neutrik cable plug NC3FX

Maximum input pressure21 bar

Pneumatic connections Plug-in nipple RBE 03

Dimensions and weight(inclusive handles, holding deviceand pneumatic connections)450 x 270 x 220 mm (W x H x D)Weight approx. 10 kg

Scope of delivery Power supply, Documentation on CETA-USB-Stick, Excel macro for measuring curve analysis, Parameterisation software, calibration certi�cate, EU declaration of conformity

Warranty 3 years

Accessories (optional) Specially assembled test hoses, cables for simple clamping to the vehicle battery, label printer

DVPG | 3KPressure Progress Test Device

Page 34: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

34

Sequence controllerPLC controlled semi-automatic test system, with manual insertion of the test part, automatic test procedure, evaluation of the measurement result (pass / fail)

Standard components• Optimised concept regarding the

pneumatical design and the technical application

• Mobile Rittal control cabinet (with drawer) including integrated maintenance unit, valve cluster and control components, savety devices, 2-hand-start

• Table frame with safety devices

• Siemens PLC (basic model) with pass / fail evaluation, malfunction indicator, acknowledge reset, emergency stop switch

• Use of components from reputed manufacturers for pneumatic and sensor technology, guiding systems and mechanical pro�les

• Prepared for the integration of a CETA test device

Components speci�c to the customerTest part �xture (CAD data in Step format required), adaption, number of clamping cylinders, modi�cation of the standard layout and additional functions

Power supply230 V AC, 5 A (standard con�guration)

Compressed air supply6 - 10 bar and 1 bar above test pressure (ISO 8573-1:2010 [1:4:1])

Modi�cations and optionsPLCSiemens S7/226 control system (24 inputs / 16 outputs)Extension of the PLC with additional modulesDisplay for visualization

Safety systemsSafety door with end position controlLight grid

CETA Leak Test SystemsLeak Test System

Optional extensions (examples)

PC connectionSignature / marking of test partSignal lampDouble receptacle for test parts with sliding table

WeightDepending on the customised modi�cations

Accessories (optional)Standard leak, master jet, leak tight 3/2-way valve, more in the CETA accessories catalogue

Scope of delivery Transport packing, engineering drawing, list with spare and wear parts, CE marking, EU conformity declaration, user manual, calibration certi�cate for test device

Short descriptionThe CETA leak detection system is conceived as a semi-automatic test stand. The modular construction and the use of standardised components allow the o�er of a price attractive system. The integration of di�erent types of test devices (leak tester, �ow tester, mass �ow tester) enables a variety of industrial solutions for the most di�erent applications and test parts. The �xture and adaption of the test part as well as optional add-ons are customerspeci�c. During the project planning phase the technical feasibility of the leak test is ensured.

Page 35: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

35

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Application example 1Mobile CETA 3-channel test system for the autonomous leak test of pneumatical systems with customer speci�c adjustments, (16 bar test pressure, pneumatical measuring line and hose reel, industrial PC controlled, network compatible, bar-code-scanner, label printing for documentation of the measuring results)

Application example 2CETA leak test system with �xture for the leak test of ball valves• Test of the internal and external tightness in di�erent positions of

the ball valve• Switching by mechanical actuator• Use of the test mode „closed component“ (volume determination

and test of gross leaks)• Use of the test mode „pressure decay test“ (test of �ne leaks)

CETA Leak Test SystemsLeak Test System

Page 36: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

36

CETA Soft 2G Application SoftwareSoftware

Range of application The control- and analysis software CETA Soft 2G has been developed especially for the communication with the CETA test device series CETATEST x15 and x 25. It enables the remote control of the test devices, the transfer of parameters, the recording and the evaluation of measured values (including the test part rating).

Supported devices • CETATEST 515 • CETATEST 615 • CETATEST 715• CETATEST 815• CETATEST 815 HD-DA• CETATEST 825• CETATEST 915• CETATEST 915-G

Overview of functions• Recording of series of measurements including measuring curves• Management of measurement series• Exchange of program parameters• Editing and analysis of test series (o�ine mode)

* Please request your free Application software CETA Soft 2G here: +49 (0)2103 2471-75  [email protected]

Application SoftwareCETA Soft 2G for free!*

Page 37: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

37

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Measurement results and series of measurements• Creating and storage of measuring series

• Continuation of a recorded series of measurements

• Im- and export of measurement series

• Management of measuring series

• Comparison of measurement series (incl. Cg- value determination)

• Input of additional data concerning a series of measurements (article number, comment)

• Storage of the measured value with date and time

Export of data • Export of data in csv-format (.csv)

• Save charts to memory device or to clipboard

Statistical evaluations• Number of all measured values of the

measurement series

• Number of the test results (pass, fail, abort)

• Maximum value, minimum value within a series of measurements

• Average value and standard deviation

• Show / hide of individual test results

• Measurementsystem analysis (MSA)

Visualization • Measurement diagram (pro�le of the

measured values, colored visualization of the measurement rating)

• Histogram (colored visualization of the measurement rating)

• Measuring curve with the option to overlay the last curve with the current curve

Parameter exchange with CETA test devices • Setting of the test mode and parameter

input over a test mode speci�c input screen

Operation of several CETA test devices• Simultaneous control of several CETA test

devices via one PC

• Storage of the measured data for each test device

O�ine mode • Analysis of the measured values without

connecting a CETA test device

• Comparison of measurement series

• Import/Export of measurement series

Languages • German and English

Minimum PC requirements • Windows XP SP3

Windows Vista, Windows 7 (32/64 bit), Windows 8 (32/64 bit), Windows 10 (32/64 bit)

• Intel Core i3 or comparable multi-core processor

• 2 GB RAM

• Screen resolution 1024 x 768

Scope of delivery • Installation CD

• USB / RS-232 Adapter (option)

Remark• Limited scope of services when operating

two-channel devices (CETATEST 715 Twin, CETATEST 815 Twin)

CETA Soft 2G Application SoftwareSoftware

Page 38: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

38

CETA Standard LeakAccessories

CETA Standard LeakThe CETA standard leak can be used for the quick and comfortable monitoring of the CETA leak testers according to the documents of quality assurance. At a selected pressure this calibration device has a de�ned �ow (ml/min). By connecting the standard leak to the measuring circuit of the leak tester a determined leak can be simulated. This procedure enables the check of the correct adjustment of the test equipment and/or the entire test system including the adapter �xture within seconds. The CETA standard leak is supplied with a calibration certi�cate.

MaterialThe leak consists of a porous sintered precision metal. According to the quality controlled manufacturing the standard leaks show a constant �ow.

Standard leaks and customized leaksIf the necessary �ow value is not listed in the CETA standard table, a customized leak can be manufactured.Special version for pressure rise test with double plug nipple connections in the front panel of the CETA leak tester.

ConnectionThe standard leak can be connected directly to the standard leak receptacle of the CETA leak tester or can be connected to the adapter �xture.

Type of connectionPressure inlet: plug nipple RBE 03Pressure outlet: • ¼ -inch outside thread• plug nipple RBE 03 (version pressure

rise)• PA tube connection (6x4/8x6/10x8)

Maintenance recommendationThe CETA standard leak has to be calibrated at regular intervals. This calibration (with certi�cate) can be done by the CETA service.

AdviceThe leak is designed for the use with clean and dry compressed air.

Scope of delivery Standard leak, calibration certi�cate, storage case

Page 39: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

39

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

CETA Standard LeakAccessories

The pressure values are speci�ed as negative resp. positive gauge pressures.

Due to production reasons, the exact �ow value is determined at the time of time of delivery.

It can deviate up to +/- 25% (Standard leak

Table of available standard leaks (excerpt)

with �ow bigger than 1 ml/min) or +/-30 % (Standard Leak with �ow smaller than 1 ml/min) from the value listed in the standard table of standard leaks.

In case the necessary value is not listed in the CETA standard leak table, a customized leak can be manufactured.

Stan

dard

Lea

k (t

ype)

Pessure/bar -0.5 -0.1 0.02 0.05 0.1 0.5 1 2 3 4 5 6 7 8 9 10

TL1 - - - - - 0.02 0.04 0.10 0.15 0.25 0.30 0.45 0.55 0.70 0.85 1.10

TL2 - - - - 0.02 0.15 0.4 0.87 1.6 2.5 3.7 4.8 6.3 7.9 9.8 11.2

TL3 - - - 0.03 0.07 0.40 0.93 2.4 4.3 6,8 9.5 13 15 20 23 27

TL4 0.5 0.12 0.02 0.07 0.15 0.8 1.8 4.5 7.9 13.5 18 24 31 40 45 52

TL5 1.1 0.23 0.05 0.10 0.25 1.5 3.5 9.5 16.5 26 34 45 57 68 82 96

TL6 2.4 0.63 0.12 0.3 0.6 3.7 8.6 21 38 58 79 102 127 154 180 210

TL7 4.8 1.15 0.3 0.65 1.3 7.5 17 45 77 115 158 202 250 300 320 370

TL8 10.5 2.7 0.6 1.4 2.8 17 38 91 156 227 305 390 470 560 590 670

TL8a 24 6 1.2 3.2 6.5 38 93 230 420 630 890 1170 1450 1750 2050 2400

TL9 46 11.5 2.5 6.4 13 74 173 440 790 1200 1600 2100 2600 3100 - -

TL10 107 28 5.9 15.5 31 185 400 880 1400 2000 2600 3200 3800 4500 - -

All �ow values are speci�ed in ml/min (pressure outlet direction).

Page 40: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

40

CETA Master JetAccessories

CETA Master JetThe CETA master jet is used for a quick and comfortable monitoring of the CETA test devices according to the documents of quality assurance. An exactly de�ned �ow combined with a pre-selected pressure is the characteristic of this calibration device.

The CETA master jet has a higher �ow than the CETA standard leak and therefore is provided for the use with CETA �ow testers (CETA 900 / CETATEST 915 / CETATEST 915-G).

For some leak test applications with large leak rates the master jet can be equipped with a plug nipple and can be connected also to leak testers.

MaterialThe master jet contains a ruby with a precision drill hole.

Standard master jetsOn the reverse side of this data sheet an excerpt of the available CETA master jets is listed.

Special master jetsIf the necessary �ow value is not found in the CETA standard table, a customized master jet can be manufactured.

Connection The master jet is connected instead of the test part.

Type of connectionPressure inlet:Optionally �tting for polyamid tube(6 x 1 mm, 8 x 1 mm, 10 x 1 mm) 1/4“ external threadPressure outlet:5 x 1 mm �tting

AdviceThe master jet is designed for the use with clean and dry compressed air.

Recommendation of maintenanceThe CETA master jet has to be calibrated in regular intervals. This calibration (with certi�cate) can be done by the CETA service.

Scope of delivery Master jet, calibration certi�cate, storage case

Page 41: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

41

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Pressure/bar 0.02 0.05 0.1 0.5 1 2 3 4 5 6 7 8

TD 1 9.6 16.5 25 59 87 137 182 230 278 322 373 420

TD 2 18.8 31.7 47 112 164 253 338 427 510 600 685 772

TD 3 50 82 120 280 400 610 810 1020 1240 1440 1650 1850

TD 4 84 137 197 460 660 1000 1360 1700 2030 2370 2700 3030

TD 5 138 225 330 740 1050 1610 2140 2670 3190 3730 4260 4660

TD 6 200 330 490 1040 1510 2280 3020 3760 4500 5240 5970 6700

TD 7 280 470 690 1510 2140 3200 4250 5310 6350 7420 8490 9560

TD 8 380 640 940 1970 2750 4130 5480 6840 8170 9520 10800 11800

Mas

te je

t (ty

pe)

Table of available standard master jets (excerpt)

The �ow values are indicated in ml/min for the master jet types TD 1 up to TD 8.

Pressure/bar 0.02 0.05 0.1 0.5 1 2 3 4 5 6 7 8 9 10

TD 10 0.8 1.5 2.1 4.5 6.0 9.6 12.0 14.3 18.2 21.0 24.4 27.3 30.0 32.6

TD 11 1.1 1.9 2.7 5.7 8.0 12.0 16.2 20.0 24.8 28.6 33.7 36.1 41.1 48.4

TD 12 1.5 2.2 3.3 7.1 10.2 15.4 20.3 25.4 30.3 34.9 40.0 44.8 50.9 54.5

TD 13 1.9 3.4 4.8 10.0 12.6 19.8 27.7 34.1 40.5 47.6 51.7 61.2 68.2 69.8

TD 14 2.2 4.0 5.5 11.8 16.1 24.7 32.7 41.7 46.8 57.7 65.2 75.0 85.7 90.9

Mas

ter j

et (t

ype)

The pressure values are speci�ed as positive gauge pressures.Master jets for negative gage pressures are available upon request.

Due to production reasons the exact �ow value is determined at the time of delivery. It can deviate up to +/-10 % from the value listed in the standard master jet table.

The �ow values are indicated in l/min for the master jet types TD 10 up to TD 14.

CETA Master JetAccessories

Page 42: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

42

ApplicationThe leak tight and pneumatically controlled 2/2-way valve can be used as a blocking valve.

UseThe 2/2-way valve is used for controlled opening or closing and is regulating the entrance, �ow or exhaust of compressed air connection pipes.Advice:Due to the integrated valve technology the 2/2-way valve has a preferential direction.The main compressed air pipe that has to be closed has to be connected to port 1.

PropertiesLeak tested poppet valve.No minimum pressure required, as the valve is externally switched by control pressure.The quality of used materials as well as the elaborated tests guarantee a high reliability and a long lifetime.

MediumAir or neutral gas (�ltered)

MaterialHousing: AluminiumInternal Components: Aluminium and steelSealing rings: Nitril NBR

Maximum leak ratemax. 0.2 cm³ / min • bar

Valve controlControl: pneumatic (option: electrical)Resetting : spring

Pneumatic controlControl pressure: 5 bar (minimum) 6 bar (maximum) Advice: At low control pressures a pressure booster has to be used. At high control pressures a pressure reducer is necessary.

Electrical control (option)If the 2/2-way valve shall not be controlled pneumatically, a separately mountable electromagnetic valve (24 V DC / 5 W) can be delivered for each 2/2-way valve (option).

Test pressure0 to 10 bar as standard, up to 16 bar on request (if control pressure 10 bar)

CETA 2/2-Way ValveValves

Page 43: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

43

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

64

36

15,5

46 38

43,5

71,5

4,0

4,0

30

Control pressure

connection

1 2

2

4,2

CETA 2/2-Way ValveValves

ConnectionPneumatic line: 6 x 1 mm Union nut connectionControl line: Quick coupling 6 mm Plug-in �tting (3 mm optional)

Nominal width4 mm

Operation temperature+ 10º C to + 40º C

Response timeApprox. 200 ms

MountingThere are 4 mounting holes with a diameter of 4.2 mm in the housing. The valves can be mounted one upon the other.

NoteThe CETA test devices can be equipped with a pneumatical output (as option), which can be used to switch the 2/2-way valve (program selective).

MaintenanceThe 2/2-way valve has to be maintained at regular intervals. This can be done by the CETA service.

WeightApprox. 0.45 kg

Scope of delivery Test record, sealing caps

Page 44: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

44

CETA 3/2-Way ValveValves

PropertiesLeak tested slide valve. No minimum pressure required as the valve is externally switched by control pressure.The quality of the used material as well as extensive tests guarantees high reliability and long durability.

MediumAir or neutral gas (�ltered)

MaterialHousing : AluminiumInternal Components : Stainless steelSealing rings : Nitril NBR

Maximum leak ratemax. 0.2 cm³/min • bar

Means of controlControl: pneumatic (option: electrical)Reset: spring

Pneumatic controlControl pressure: 5 bar (minimum) 6 bar (maximum) Advice: At low control pressures a pressure booster has to be used. At high control pressures a pressure reducer is necessary.

Electrical control (option)If the 3/2-way valve shall not be controlled pneumatically, a separately mountable electromagnetic valve (24 V DC / 5 W) can be delivered for each 3/2-way valve (option).

Test pressure0 to 10 bar and -1,000 mbar as standard, up to 16 bar on request (if control pressure 10 bar) Advice: If the pressure at connection no. 3 is much higher than at connection 1 (meaning p3 » p2), the pneumatic line between connection no. 1 and no. 2 might be shut.

Application

The leak tight and pneumatically controlled 3/2-way valve can be used for bidirectional operation. Typical applications are switching between measurement points or external exhausting.

Switching between test points

Fixture 1 Fixture 2

Test Device

RT

External exhausting

Fixture

Test Device

RT

Page 45: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

45

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

ConnectionPneumatic line:

Standard: 6 x 1 mm Union nut connection On request: 8 x 1 mm Union nut connection or 6 mm clamping ring or 4 mm clamping ring or 3 mm clamping ring

Control line:Quick coupling 6 mm Plug-in �tting (3 mm optional)

Nominal width4 mm

Operation temperature+ 10º C bis + 40º C Response timeApprox. 200 ms

MountingThere are 4 mounting holes with a diameter of 4.2 mm in the housing. The valves can be mounted one upon the other.

NoteThe CETA test devices can be equipped with a pneumatical output (as option), which can be used to switch the 3/2-way valve (program selective).

MaintenanceThe 3/2-way valve has to be maintained at regular intervals. This can be done by the CETA service

Weightapprox. 0.45 kg

Scope of delivery Test record, sealing caps

4436

30

97

145429

ø 4,2

1

2 3Steuerdruck-anschluss

CETA 3/2-Way ValveValves

Page 46: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

46

CETA Filter CombinationFilter

ApplicationThe �lter combination consists of two �lter systems, which are connected in series. A manometer (econometer) is mounted at the input connection and displays the abrasion.The econometer controls the current pressure di�erence and informs about the necessary change of the used �lter element.

DimensionsH x W x D: 295 mm x 266 mm x 130 mm(Height incl. manometer) Pneumatic connection: G ¼“ (input and output)

MountingThe �lter combination has to be mounted vertically.

MediumAir oder neutral gas (�ltered)

MaterialSurface : Polyester resin (powder-coated)Case : Aluminium pressure castingUnion nut : Aluminium with acoustic warning signalEconometer : PlasticEnclosure sealing : Solvent free O-ring (material Perbunan)

Weight1.0 kg (volume 0.37 l) per �lter

Operating pressureMinimum: 1.5 bar, maximum: 16 barFilter combinations for maximum pressures of 50 bar resp. 350 bar are available on request.

OutputInput Output

Page 47: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

47

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Filter elements1. Filter stage (PE �lter unit)Sintered polyethylenePore size 25 μmSeparation of solid particles, oil and water

2. Filter stage (SMF �lter unit)Polyurethane micro�lter �eecePore size 0.01 μmSeparation e�ciency 99.99999 %Concentration of remaining oil 0.01 mg/m³

Functioning1. Filter stage (PE �lter unit): Compressed air, contaminated with �ne dust is �ltered by the �lter material. Solid particles, which are larger than 25 μm, cannot pass the �lter because of di�erent �lter processes like impact and �ltration.

2. Filter stage (SMF �lter unit): E�ective two stage �lter process with a integrated 1 μm upstream �lter. Fluid and solid particles up to a size of 0.01 μm will be separated by using di�erent �lter processes like impact, �ltration and di�usion.

We recommend the exchange of the PE- and SMF �lter units after one year at the latest referring to the degree of soiling.

Permissible temperaturesEnclosure: min. -25°C / max. +120°CEconometer (manometer): max. +60°CPE �lter unit: max. +80°CSMF �lter unit: max. +80°C

FixingIn the scope of delivery included wall mount. The �lter combination is delivered pre-assembled. Before installing only the both wall fastenings must be mounted to the right and left. Please remove the cap nuts and spring washers, slide the wall fastening to the threaded bar and secure it with the lock washer and the nut.

Scope of delivery 2-stage �lter combination with PE- and SMF-�lter unit, wall fastening, screws, installation manual Advice:The package does not include �ttings that in the �lter combination on input and output 1/4 inch thread can be scewed. Matching �ttings: see our accessories catalog.

1. Filter stage PE �lter unit

2. Filter stage SMF �lter unit

Filter elements

CETA Filter CombinationFilter

Page 48: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

48

CETA ServiceService

Overview of services• Service work on CETA leak and �ow testers

• Maintenance on request, calibration and repair of leak and �ow testers from other manufacturers

• Customer support by phone

• Performing of DAkkS calibrations for pressure and factory calibrations for pressure and �ow (details below)

• Rental of replacement equipment (depending on availability)

• Subject to prior agreement, on-site servicing and calibration in Germany and abroad (including planning and coordination of dates for on-site appointments)

• Maintenance contracts adapted to the speci�c needs of the customers with commitment to a �xed maintenance schedule

• Life cycle documentation of all CETA test devices in test device �les, including repair, maintenance, calibration and modi�cations

• O�ce hours: Monday to Friday from 8:00 to 17:00

• Maintenance and service training for speci�c applications

Performance data• More than 1200 servicing assignments per year

• 75 % maintenance and calibration work, recalibration of test leaks and master jets

• 25 % repair, modi�cation

• 95 % of the maintenance and calibration works scheduled by appointment are generally completed within 1 - 2 working days processing time.

• If any defects are detected, an estimate of costs will be provided automatically.

DAkkS calibrations and factory calibrations for the measurand pressure• The calibration laboratory of CETA Testsysteme GmbH is

accredited as DAkkS calibration laboratory (D-K-19566-01-00) for the mechanical measurand pressure.

• DAkkS calibrations can be performed within a pressure range of -1 bar to +60 bar, using gas as test medium.

Factory calibrations for the measurand �ow• Factory calibrations cover the �ow range of 0.1 ml/min to

220 l/min.

Page 49: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

49

Basics• Check of the electrical and pneumatic components

• Initial calibration of pressure sensors prior to adjustment

• Hardware and �rmware updates if technically required

• Cleaning of the whole device (inside and outside)

• Shipment of the equipment in special packaging

Work on electrical components• Measurement of the supply voltages including correction if

needed

• Electric protection tests according to standards, including necessary revisions

Work on pneumatic components• Assessment, dismantling and cleaning of all removable parts

(valves, multifunction valve, bypass, pressure regulator, etc.)

• Check of the pre-pressure regulator and adjustment if necessary

• Replacement of wear material (grease, O-rings, springs, protecting caps, sound absorbers, etc.)

• Calibration of the gage pressure sensors and di�erential pressure sensors at several measuring points (in positive and negative gage pressure range)

• Control of the hysteresis of the measuring cells

Test and documentation• Multi-stage test phases and �nal tests adapted to the

di�erent test modes, including endurance test

• Logged function tests, DAkkS- or factory calibration certi�cates, update lists, maintenance protocols, graphical printouts, repair reports for the customer

• In-house documentation of all works performed on the devices

CETA ServiceService

Page 50: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

50

DAkkS- and Factory Calibration LaboratoryLaboratory

DAkkS calibrations - measurand pressureThe calibration laboratory of CETA has been accredited as DAkkS calibration laboratory (D-K-19566-01-00) for the measurand pressure. By use of the test medium gas we provide DAkkS calibrations in the measuring range of -1 bar to +60 bar in the permanent laboratory and on-site (details regarding measurand, measuring range and measuring uncertainty see next page).The DAkkS calibration is carried out in accordance with the norm DIN EN ISO/IEC 17025.The calibration certi�cate of a DAkkS laboratory automatically documents traceability to national standards. Regular audits by the DAkkS ensure the high quality of the used measuring equipment and the test procedures.By multilateral agreements the DAkkS calibration certi�cate is accepted in many countries. You will �nd more information on the homepages of the ILAC, the EA and the DAkkS (Deutsche Akkreditierungsstelle GmbH).

DAkkS calibrations - measurand pressure Factory calibrations - measurand pressure & �ow

Factory calibrations - measurand pressureThe pressure range of -1 bar to +60 bar is also covered by factory calibrations. Factory calibrations are realized with DAkkS calibrated instruments. The traceability of the used measuring equipment is documented in detail.

Factory calibrations - measurand �owBy factory calibration the �ow range of 0.1 ml/min to 220 l/min is covered. The used calibration standards are calibrated regularly with DAkkS calibration certi�cate at accredited institutes.

Meaning of the traceability of measurement and test equipment. The certi�cation according DIN ISO 9000 in the industrial environment and the quality management requires the traceability of the measuring equipment to national standards. Advantage of traceable measuring and testing equipment:• Certainty in production• Securing a constant product and

manufacturing quality• Assurance of the market position• Build-up of customer con�dence

Page 51: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

51

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

* Speci�ed are the standardized values by conversion to Pabs = 1,000 mbar and T = 20 °C as reference condition to ISO 1217. 1) Measurement capabilities stated according to EA-4/02 M:2013. These are expanded uncertainties with a coverage probability of approximately 95 % (coverage factor of k = 2). 2) The uncertainty for measured quantity �ow are typical measuring uncertainties.

DAkkS calibrations for measurand pressure - Permanent Laboratory

Measured quantity / Calibration item

Range Measurement conditions / procedure

Expanded uncertainty of measurement1)

Remarks

PressureNegative and positive gauge pressure pe

-1.0 bar to -0.07 barDKD-R 6-1: 2014DIN EN 837: 1997

0.4 mbarPressure transfer medium: gas > -0.07 bar to -0.01 bar 3.5 Pa

> -0.01 bar to 0.03 bar 3•10-4 • pebut not lower than 3 µbar

> 0.03 bar to 0.07 bar 3.5 Pa

> 0.07 bar to 1.0 bar 0.4 mbar

> 1.0 bar to 17 bar 8 mbar

> 17 bar to 30 bar 20 mbar

> 30 bar to 60 bar 30 mbar

DAkkS calibrations for measurand pressure - On-site-calibration

Measured quantity / Calibration item

Range Measurement conditions / procedure

Expanded uncertainty of measurement1)

Remarks

PressureNegative and positive gauge pressure pe

-1,0 bar to -0.07 barDKD-R 6-1: 2014DIN EN 837: 1997

0.4 mbarPressure medium: gas> -0.07 bar to 0.07 bar 3,5 Pa

> 0.07 bar to 1.0 bar 0.4 mbar

> 1.0 bar to 17 bar 8 mbar

> 17 bar to 30 bar 20 mbar

> 30 bar to 60 bar 30 mbar

Factory calibrations for measurand �ow

Measured quantity Range Procedure Uncertainty 2) Remarks

Flow 0.1 ml/min to 1 ml/min* CETA calibration instructions

5 % of measuring value Flow medium: gas

>1 ml/min to 220 l/min* 3 % of measuring value

DAkkS- and Factory Calibration LaboratoryLaboratory

Page 52: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

52

International Cooperation Partners

52

Germany CETA Testsysteme GmbH40721 Hildenwww.cetatest.comMain o�ce +49 2103 2471 [email protected] +49 2103 2471 [email protected] +49 2103 2471 [email protected]

PolandTechControl47-400 RacibórzMr. Adam [email protected] +48 32 4578043

Czech RepublicCRESSTO s.r.o.756 61 Roźnov Pod RadhoštěmMr. Michal Konvičný[email protected]://cressto.cz +420 571 845 338

HungaryIGS-Kontakt Kft1147 Budapest Mr. Géza Pál�pal�[email protected]://www.igs-kontakt.hu +36-1-221 8573

SpainAplival, S.L.46136 Museros (Valencia)Mr. Antonio Palanca [email protected] +34 96 145 2256

Europe America

MéxicoMeyerV, S.A. de C.V.52175 MetepecMr. Carlos [email protected]://meyerv.com.mx +52 722 216 21 88

PortugalTOJALTEC - Fabrico de Máquinas, Lda.3465-190 TONDELAMr. Cândido [email protected] +35 1 232 848 042

52

Page 53: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

53

Subj

ect t

o m

odi�

catio

n du

e to

tech

nica

l pro

gres

s |

Sep

tem

ber 2

019

CETA Testsysteme GmbH Marie-Curie-Str. 35-37 | 40721 Hilden - Germany | phone +49 2103 2471 - 75 | fax +49 2103 2471 - 76 | [email protected] | www.cetatest.com

International Cooperation Partners

Asia

SingapurLFC PTE. LTD.Singapore 408538 Mr. Temmy [email protected] +65 67499697

IndonesiaPT. Yakin Maju Sentosa Jakarta 11180 Mr. Kwa Tjie [email protected] +62 21 6263851

South KoreaETC Co., Ltd.Uiwang-Si, Kyinggi-DoKorea (437-753)Dr. Lee Wan-Bae [email protected] +82 31 4271780

ThailandMax Value Technology Co., Ltd.Bangkok 10250Mr. Manat [email protected] www.maxvalue.co.th +66 2717 7199

IndiaSP LEAK TEST & AUTOMATION PVT LTD.Kamakshipalya, Bangalore 560079, KarnatakaMr. Mishra [email protected] +91 80 23 48 41 47

P. R. ChinaDantsin Technologies Ltd.Beijing 101300Mrs. May [email protected]@dantsin.cnwww.dantsin.com +86 10 5822 0390 8003

TurkeyTEKIN Otomasyon Sanayi ve Ticaret Ltd. Şti.Nilüfer / BursaMr. Erdem [email protected] +90 532 162 8150

Page 54: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

54

Notices

Page 55: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

55

Page 56: CETA Testsysteme GmbH · 2019. 11. 7. · CETA o˜ers a wide range of services like consulting, feasibility studies, engineering, training, instruction, installation, setting-up operation,

September 2019

CETA Testsysteme GmbH Marie-Curie-Strasse 35-37 | 40721 Hilden - Germany tel +49 2103 2471 - 0 | fax +49 2103 2471 - 71 [email protected] | www.cetatest.com

Sales tel +49 2103 2471 - 75 fax +49 2103 2471 - 76 [email protected]

Service tel +49 2103 2471 - 72 fax +49 2103 2471 - 78 [email protected]