    1

    0.6/1(1.2) KV AL - Aerial Bundled Cable for Overhead Distribution Lines.IEC 60228, IEC 60811, BS 2627, IEC 60502-1 : 2004

    S/N Cable SizeStandard Packing Street Lighting

    Length(m)

    Weight(kg)

    No.ofstrands

    Diameter(mm)

    Cross-section

    area(mm2)

    Max.conductor

    resistance at20ºC deg(ohm/km)

    No.ofstrands

    Diameter(mm)

    Cross-section

    area(mm2)

    Max.conductor

    resistance at20ºC deg(ohm/km)

    No.ofstrands

    Diameter(mm)

    Cross-section

    area(mm2)

    Max.conductor

    resistance at20ºC deg(ohm/km)

    11 x 16mm2 + 1 x25mm2

    1000 170 7 4.9 16 1.91 7 6.0 25 1.312 - - - - 55

    23 x 16mm2 + 1 x25mm2

    1000 285 7 4.9 16 1.91 7 6.0 25 1.312 - - - - 50

    33 x 35mm2 + 1 x25mm2

    1000 500 7 7.0 35 0.868 7 5.9 25 1.312 - - - - 123

    43 x 50mm2 + 1 x35mm2

    1000 680 7 8.4 50 0.641 7 7.0 35 0.99 - - - - 147

    53 x 70mm2 + 1 x50mm2

    1000 940 19 9.9 70 0.443 7 8.4 50 0.69 - - - - 164

    63 x 95mm2 + 1 x70mm2 + 1 x16mm2

    500 848 19 11.7 95 0.320 19 9.9 70 0.469 7 4.9 16 1.91 189

    73 x 185mm2 + 1 x120mm2 + 1 x16mm2

    500 1540 37 16.2 185 0.164 19 13.0 120 0.273 7 4.9 16 1.91 279

    Phase Conductor Messenger/Suspension Unit Continuouscurrentrating at

    30ºCambienttemp (A)

  • Central Cables Berhad

    AERIAL BUNDLED CABLE (ABC)- MEDIUM VOLTAGE (MV)

    2

    6.35/11kV AL - Aerial Bundled Cable for Overhead Distribution Lines.IEC 60502-2: 2005

    No. ofstrands

    WireDiameter

    (mm)

    Nominalcross-section

    area(mm2)

    Maxconductor

    resistance at20ºC

    No. ofstrands

    WireDiameter

    (mm)

    Nominalcross-section

    area(mm2)

    BreakingLoad(kN)

    2 3C x 70mm2 +

    1C x 50mm2 19 2.14 70 0.443 7 3.15 50 62 210

    3 3C x 95mm2 +

    1C x 50mm2 19 2.52 95 0.320 7 3.00 50 60 173

    4 3C x 185mm2 +

    1C x 120mm2 37 2.52 185 0.164 7 4.67 120 150 259

    5 3C x 150mm2 +

    1C x 50mm2 37 2.25 150 0.206 7 3.15 50 62 365

    6 3C x 240mm2 +

    1C x 50mm2 61 2.25 240 0.125 7 3.15 50 62 500

    Continuouscurrentrating

    at30ºC

    ambienttemp (A)

    S/N Cable Size Phase Conductor Messenger/Suspension Unit

    1 3C x 50mm2 +

    1C x 25mm2 19 1.78 50 0.641 7 3.00 50 60 116

  • Central Cables Berhad

    AERIAL BUNDLED CABLE (ABC)MEDIUM VOLTAGE (MV)

    3

    19/33kV AL - Aerial Bundled Cable for Overhead Distribution Lines.IEC 60502-2: 2005

    No. ofstrands

    WireDiameter

    (mm)

    Nominalcross-section

    area(mm2)

    Maxconductor

    resistance at20ºC

    No. ofstrands

    WireDiameter

    (mm)

    Nominalcross-section

    area(mm2)

    BreakingLoad(kN)

    Continuouscurrentrating

    at30ºC

    ambienttemp (A)

    S/N Cable Size Phase Conductor Messenger/Suspension Unit

    1 3C x 50mm2 +

    1C x 50mm2 19 1.78 50 0.641 7 3.00 50 60 165

    3 3C x 185mm2 +

    1C x 70mm2 37 2.52 185 0.164 7 3.57 70 91 355

    4 3C x 70mm2 +

    1C x 50mm2 19 2.14 70 0.443 7 3.15 50 62 250

    2 3C x 150mm2 +

    1C x 50mm2 37 2.25 150 0.206 7 3.00 50 60 315

    5 3C x 150mm2 +

    1C x 50mm2 37 2.25 150 0.206 7 3.15 50 62 370

  • Central Cables Berhad

    AERIAL BUNDLED CABLE (ABC)- MEDIUM VOLTAGE (MV)

    Cross Section of Medium Voltage Aerial Bundled Cable

    No. Description 1

    2

    3

    4

    5

    6

    7

    8

    Conductor

    Conductor Screen

    Insulation

    Insulation Screen

    Metallic Screen

    Binder

    Outer Sheath

    Messenger

    1

    2

    3

    4

    5

    6

    7

    8

    4

  • Central Cables Berhad

    BARE ALUMINIUM CONDUCTOR

    5

    Stranded Aluminium ConductorStranded Multi Wires To BS 6360:1991

    Size of ConductorNominal cross

    sectional area ofconductor

    No. & sizeof wire

    Nominal diameterof conductor

    Maximumresistance at

    20ºCApprox.mass

    mm2 No./mm mm kg/km

    4610162535507095120

    1501852403004005006308001000

    7/0.857/1.047/1.357/1.7019/1.3519/1.5319/1.7819/2.1419/2.5237/2.03

    37/2.2537/2.5261/2.2561/2.5261/2.8561/3.2061/3.63127/2.85127/3.20

    2.553.124.055.106.427.658.9010.7012.6014.21

    15.7517.6420.2522.6825.6528.8032.7637.0541.60

    7.414.613.081.911.200.8680.6410.4430.3200.253

    0.2060.1640.1250.1000.07780.06050.04690.03670.0291

    10.1016.0027.0042.2069.5094.1012.58183.00255.18323.36

    405.30500.00648.10810.101073.001350.001701.892162.002703.00

  • Central Cables Berhad

    ALL ALUMINIUM CONDUCTOR (AAC)

    Standard Sizes of All Aluminium Conductors for Overhead PowerTransmission

    ConductorNominal

    crosssectional area of

    conductor

    mm2

    Equivalentcopperarea

    Construction

    No. / wirediameter

    Approx.overall

    diameter

    Calculatedbreaking

    load

    CalculatedD.C

    resistanceat 20ºC

    Approx.Net

    Weight

    CodeName

    mm2 mm2 mm kN kg/km

    22

    50

    60

    100

    150

    200

    250

    300

    400

    14.2

    32.2

    38.78

    64.7

    96

    130

    162

    197

    253

    7/2.06

    7/3.10

    7/3.40

    7/4.39

    19/3.25

    19/3.78

    19/4.22

    19/4.65

    37/3.78

    6.18

    9.30

    10.20

    13.17

    16.25

    18.90

    21.10

    23.25

    26.46

    3.99

    8.28

    9.90

    16.00

    24.70

    32.40

    40.40

    48.75

    63.10

    1.227

    0.5419

    0.4505

    0.2702

    0.1825

    0.1349

    0.10830

    0.08916

    0.06944

    64

    144

    175

    291

    435

    586

    730

    886

    1143

    Midge

    Ant

    Fly

    Wasp

    Hornet

    Chafer

    Cockroach

    Centipede

    6

  • Central Cables Berhad

    Stranded Hard - Drawn All AluminiumConductor (AAC)

    7

    Nominal

    crosssectional area of

    conductor

    ConstructionNo. / wirediameter

    Calculatedarea

    Approx.overall

    diameter

    Approx.net

    weight

    Minimumbreaking

    load

    CalculatedDC

    resistanceat 20ºC

    Hard-drawncopper

    equivalentarea

    mm2 No./mm mm2 mm kg/km kgf mm2

    30

    38

    55

    95

    150

    200

    240

    300

    400

    510

    660

    850

    980

    1260

    7/2.3

    7/2.6

    7/3.2

    7/4.2

    19/3.2

    19/3.7

    19.4.0

    37/3.2

    37/3.7

    37/4.2

    61/3.7

    61/4.2

    91/3.7

    91/4.2

    29.09

    37.16

    56.29

    96.95

    152.8

    204.3

    238.8

    297.6

    397.8

    512.5

    655.8

    844.9

    978.3

    1260

    6.9

    7.8

    9.6

    12.6

    16.0

    18.5

    20.0

    22.4

    25.9

    29.4

    33.3

    37.8

    40.7

    46.2

    80

    102

    154

    265

    419

    560

    645

    820

    1090

    1410

    1820

    2330

    2710

    3500

    469

    575

    838

    1410

    2270

    3030

    3490

    4430

    5890

    7460

    9720

    12300

    14500

    18350

    0.983

    0.769

    0.507

    0.295

    0.188

    0.140

    0.120

    0.0969

    0.0726

    0.0563

    0.0441

    0.0342

    0.0297

    0.0230

    12.62

    23.34

    35.35

    60.88

    95.96

    128.3

    150.0

    186.9

    249.8

    321.9

    411.8

    530.6

    614.4

    791.3

  • Central Cables Berhad

    All Aluminium Alloy Conductor (AAAC)

    Standard Sizes of All Aluminium Conductors for Overhead PowerTransmission

    ConductorNominal

    crosssectional area of

    conductor

    mm2

    Equivalentcopperarea

    Construction

    No. / wirediameter

    Approx.overall

    diameter

    Calculatedbreaking

    load

    CalculatedD.C

    resistanceat 20ºC

    Approx.Net

    WeightCodeName

    mm2 No./mm mm kN kg/km

    25

    30

    40

    50

    100

    150

    175

    300

    16.2

    19.1

    25.8

    32.3

    64.5

    97

    113

    194

    7/2.34

    7/2.54

    7/2.95

    7/3.30

    7/4.65

    19/3.48

    19/3.76

    37/3.53

    7.02

    7.62

    8.85

    9.90

    13.95

    17.40

    18.80

    24.71

    8.44

    9.94

    33.30

    50.65

    59.10

    101.50

    13.4

    16.80

    1.094

    0.9281

    0.6880

    0.5498

    0.2769

    0.1830

    0.1568

    0.09155

    81

    98

    130

    165

    137

    495

    578

    995

    Almond

    Caedar

    Fir

    Hazel

    Oak

    Ash

    Elm

    Upas

    8

  • Central Cables Berhad

    Bare All Aluminium Alloy Conductor (AAAC)

    9

    Aluminium alloy (AAAC) contains a small percentage (about 0.6%) of silicon and magnesium elements. It

    (i) Strength : About twice that of aluminium 1350 (EC).

    (ii) Weight : 20% (approx.) lighter than ACSR conductor of equal diameter.

    (iii) Corrosion resistance : It has a high resistance to atmospheric corrosion which is suitable for coastal and indusrial areas.

    liable to damage during installation which is an important advantage of EHV transmission lines where corona and radio interference is a major consideration.

    (v) Termination : Much simpler jointing accessories required compared to ACSR.

    (vi) AC Resistance : AAAC is an non-magnetic material. It does not exhibit the magnetic core losses found in ACSR conductor

    7(1 + 6) 19(1 + 6 + 12) 37(1 + 6 +12 + 18)

    6(1 + 6 + 12 + 18 + 24) 91(1 + 6 + 12 + 18 + 24 + 30) 127(1 + 6 + 12 + 18 + 24 + 30 + 36)

  • Central Cables Berhad

    Aluminium Conductor Steel Reinforced (ACSR)

    Standard Sizes of All Aluminium Conductors Steel Reinforced for OverheadPower Transmission.

    Conductor

    Nominal Al.

    area

    Equivalentcopperarea

    ActualSectional

    Construction

    No./ Size of Wire

    Approx.overall

    diameter

    Calculatedbreaking

    load

    CalculatedD.C

    resistanceat 20ºC

    Approx.Weight

    CodeNameAI Steel

    AI. Steel AI. Steel

    mm2 mm2 mm2 mm2 No./mm No./mm mm kN ohm/km kg/km kg/km

    25

    30

    40

    50

    *60

    70

    100

    150

    150

    175

    175

    200

    200

    *300

    400

    16.0

    19.3

    25.8

    32.3

    38.6

    44.8

    64.0

    96.4

    96.8

    111.9

    112.4

    129.0

    128.0

    197.0

    262.0

    26.25

    31.61

    42.41

    52.88

    63.22

    73.37

    105.0

    158.1

    158.7

    183.4

    184.3

    212.1

    210.6

    323.0

    428.9

    4.37

    5.27

    7.07

    8.81

    36.88

    42.8

    13.5

    36.8

    8.8

    42.8

    10.2

    49.5

    11.7

    15.5

    55.6

    6/2.36

    6/2.59

    6/3.00

    6/3.35

    12/2.59

    12/2.79

    6/4.72

    30/2.59

    18/3.35

    30/2.79

    18/3.61

    30/3.00

    18/3.86

    18/4.78

    54/3.18

    1/2.36

    1/2.59

    1/3.00

    1/3.35

    7/2.59

    7/2.79

    7/1.57

    7/2.59

    1/3.35

    7/2.79

    1/3.61

    7/3.00

    1/3.86

    7/1.68

    7/3.18

    7.08

    7.77

    9.00

    10.05

    12.95

    13.95

    14.15

    18.13

    16.75

    19.53

    18.05

    21.00

    19.30

    24.16

    28.62

    9.61

    11.45

    15.20

    18.35

    52.94

    61.20

    32.70

    69.20

    35.70

    79.80

    41.10

    92.25

    46.55

    69.67

    131.90

    1.093

    0.9077

    0.6766

    0.5426

    0.4566

    0.3936

    0.2733

    0.1828

    0.1815

    0.1576

    0.1563

    0.1363

    0.13670

    0.08914

    0.06740

    72

    87

    117

    145

    175

    203

    288

    437

    437

    507

    507

    586

    580

    887

    1186

    34

    41

    55

    69

    289

    335

    106

    289

    69

    335

    81

    388

    91

    123

    435

    Gopher

    Weasel

    Ferret

    Rabbit

    Skunk

    Horse

    Dog

    Wolf

    Dingo

    Lynx

    Caracal

    Panther

    Jaguar

    Batang

    Zebra

    Note: 1) *Not a standard Size in BS 215 : Part 2.

    ACSR is a composite, concentrically stranded conductor in which the light weight and good conductivity

    of aluminium are combined with the high tensile strength of steel. It is composed of one or more layers

    of EC grad hard-drawn aluminium wires helically stranded around an inner core of high strength zinc-

    coated steel wires. The inner steel core may be a single zinc coated steel wire, or concentrically stranded

    of one or more layer of zinc-coated steel wires.

    ACSR has long been widely used as overhead high tension transmission lines and has an established

    reputation for economy and dependability. The illustrarion below shows typical standard sizes and

    stranding patterns.10

  • Central Cables Berhad

    Bare Aluminium Conductor Steel Reinforced(ACSR)

    11

    6 + 1 6 + 7(1 + 6) 12 + 7(1 + 6) 14 + 7(1 + 6) 14 + 19(1 + 6 + 12)

    18(6 + 12) + 1 24(9 + 15) + 7(1 + 6) 26(10 + 16) + 7(1 + 6) 30(12 + 18) + 7(1 + 6)

    45(9 + 15 + 21) + 7(1 + 6) 48(10 + 16 + 22) + 7(1 + 6) 58(12 + 18 + 24) + 7(1 + 6) 30 (12 + 18) + 19(1 + 6 + 12)

    54(12 + 18 + 24) + 19(1 + 6 + 12) 72(9 + 15 + 21 + 27) + 7 (1 + 6) 84(12 + 18 + 24 + 30) + 19(1 + 6 +12)

  • Central Cables Berhad

    LOW LOSS CONDUCTORTHERMAL ALUMINIUM ALLOY CONDUCTOR STEEL REINFORCED

    (STEEL ALUMINIUM CLAD) / TRAPEZOIDAL SHAPED WIRE (TACSR(SA)/TW)

    12