Categories - w6.adi-dist.comw6.adi-dist.com/customer/documents/catalog-us/Q2_2010/np/Fire.pdfSmoke...
-
Upload
truongkhanh -
Category
Documents
-
view
217 -
download
2
Transcript of Categories - w6.adi-dist.comw6.adi-dist.com/customer/documents/catalog-us/Q2_2010/np/Fire.pdfSmoke...
1-7 Zone & 8 Zone & Up ConventionalDigital Fire Communicators
Addressable ControlsCommercial Fire/Intrusion Panels
Voice EvacuationP/E Smoke DetectorsBeam/Duct Detectors
Wireless/Addressable Smoke DetectorsSpecialty Smoke Detectors
Smoke Detector Accessories
Initiation DevicesFlame Detectors
Gas DetectorsPull Stations
Notification AppliancesSounder/Strobes
StrobesSpeaker/Strobes
Notification AccessoriesPower Supplies & Surge Protection
Additional Fire Solutions
FireCategories
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us78
Fire
10-Zone Conventional Control PanelSK-5208 •10zones:8ClassB(StyleB)and
2ClassA(StyleD)/ClassB(StyleB)zones•Expandableto30zones•SupervisedzoneexpandersandI/Omodulescanbe
mountedremotelyawayfrommaincontrolpanel•Allzonesarecompatiblewithlisted2-or4-wiresmoke
detectors•Built-inDACT
2-Zone Conventional Control PanelSK-SK2•2StyleB(ClassB)InitiatingDeviceCircuits•1StyleY(ClassB)NotificationApplianceCircuit•3ampstotalusablecurrent• Form-Calarmandtroublerelays•24VDC
4-Zone Conventional Control PanelSK-SK4•4StyleB(ClassB)InitiatingDeviceCircuits•2StyleY(ClassB)NotificationApplianceCircuits•3ampstotalusablecurrent(expandableto6amps)• Form-Calarmandtroublerelays•24VDC
1-7 Zone and 8 Zone and Up - Digital Fire CommunicatorsComplete Fire Control Panel ProtectionDK-TSS1•Shipswith120VACprotectionand5-positionbase•MixandmatchmodulestoprotectACpower,SLC,IDC
andNACloops•CallyourADIrepresentativeforexactpartnumber
configurationsDK-TSS2•Shipswith120VACprotectionand2-positionbase
DK-TSS3•Shipswith2-positionhardwiredbase
DK-TSS4•Shipswith120VACprotection
Fire Alarm Control Panel with Built-in SynchronizationFL-MS2•NACprogrammableforstrobesynchronization•Upto2.5ampsofNACpower•2StyleB(ClassB)initiatingdevicecircuits•1StyleY(ClassB)notificationappliancecircuits•24VDC
READY
Fire Alarm Panel with Built-in SynchronizationFL-MS4•4StyleB(ClassB)initiatingdevicecircuits•6programmableNACoptions•Upto5.0ampsofNACpower•2StyleY(ClassB)notificationappliancecircuits•Built-instrobesynchronization•24VDC
READY
Fire Alarm Control PanelFL-MS5UD•5programmableStyleB(ClassB)
IndicatingDeviceCircuits•4StyleY(ClassB)NAC(NotificationApplianceCircuit)•Built-inDACT(DigitalAlarmCommunicator/Transmitter),
LCDDisplayandKeypad•Buildinprogrammer•NACprogrammableforstrobesynchronization•3ampsofNACpower•24VDCoperation
Fire Alarm Control PanelFL-MS10UD•10programmableStyleB(ClassB)
IndicatingDeviceCircuits•4StyleY(ClassB)NAC(NotificationApplianceCircuit)•Built-inDACT(DigitalAlarmCommunicator/Transmitter),
LCDDisplayandKeypad•Buildinprogrammer•NACprogrammableforstrobesynchronization•7ampsofNACpower•24VDCoperation
Fire Alarm CommunicatorFL-411UDAC•4supervisedmonitoringinputs:
*(3)fixedClassB*(1)ClassAorClassB
•1.0ampNACpower•Slaveorstandalone•12VDCoperation•ProgramviaFL-PK411UDorFL-PRO411programmer
Digital Alarm CommunicatorFL-DACTUD2•DualphonelinecommunicatorforFL-MS9600LS•Built-inmodemfacilitatesremoteupload/downloadon
theFL-MS9600LS•MountsonFL-MS9600LSmotherboard,noadditional
enclosurerequired
NEW MS-5UD and MS-10UD Conventional Fire Alarm Control PanelsFL-MS5UDFL-MS10UD• ReplacesFL-MS5012,FL-MS5024,FL-MS5024UD,
FL-MS2410BandtheFLMS-5210UD.Thesefirecontrolpanelshavefeaturesnormallyfoundinmoreexpensiveaddressablesystems:*Built-inkeypad&80-characterLCDdisplay*Compatiblewithi3smokedetectorsfromSystemSensor*On-boarddigitalcommunicator&removableterminals*Newlow-costANN-Busannunciators*ProgrammableNACSwithbuilt-insyncforSystem
Fire Control & Long Range Radio7720ULFPLUS 7720ULFKT-EX 7720ULFKT •UtilizesAlarmNet-Aservice•Allowsdirectconnectiontowaterflowdetectors,
pullstations,andsupervisoryswitches•Eliminatestheneedforbothphonelines•Fullyintegratedcontrolpanel•Eightzones:TwoClassA,SixClassB
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 79
FireDigital Fire Communicators - Addressable Controls
6-Zone Fire Alarm CommunicatorSK-5104•6fullysupervisedinputs:
1ClassA(StyleB)&5ClassB(StyleA)•Canbeusedasastand-aloneorasaslaveDACT•Downloadableforremoteprogramming•Fuselessoverloadprotectionwithautomaticreset
circuitryandfaultindicatoreliminatesthecauseofmostfieldcalls
Stand-Alone Commercial Fire CommunicatoriGSMCF •Triple-pathTechnology•UniversalControlPanelCompatibility•SixInputZones•FullContactIDorADEMCOHigh-SpeedReporting•256-bitAESEncryption•Upload/DownloadandDynamicSignalingwithselect
HoneywellControlPanels•DiagnosticLEDs•IntelligentSupervision•QualityofServiceDiagnostics•Web-basedprogramming
Stand-Alone Commercial Fire CommunicatorGSMCF •Dual-pathTechnology•UniversalControlPanelCompatibility•SixInputZones•FullContactIDorADEMCOHigh-SpeedReporting•256-bitAESEncryption•Upload/DownloadandDynamicSignalingwithselect
HoneywellControlPanels•DiagnosticLEDs•IntelligentSupervision•QualityofServiceDiagnostics•Web-basedprogramming
Telguard Digital Cellular CommunicatorAD-TG7F•AllDigitalGSMCellularNetwork•ULListedforCommercialFire•Redmetalenclosurewithlock&key•TelephoneLineMonitor&powersupply•ContactID,SIA2&PulseFormats-FullZoneData•DMP&ModemIle/Illa2formatswillrequireModemCard
(AD-TGMC)•Plug&PlayInstallation
Slave Digital Alarm Comm. TransmitterFL-411•4ClassBmonitoringinputs,(3inputson411)• “DialerRunaway”prevention•12or24VDCoperation,fieldselectable•ProgramviaFL-PRO411orFL-PK411UD
(FL-411UDonly)
Directory AnnunciatorsLE-DA Series •AlarmandAlarmorTroubleperzone•Non-polarizedLEDsfor12or24VDCoperation•Commonnegativeorpositive•Easytochangewordingforzonewindows•Optionalgeneralsystemtroubleandaudibleavailable
Custom Graphic AnnunciatorsLE-LD Series •Providequickandeasyidentificationalongwithlocation
ofalarmevents•HighbrightnessLEDsindicateexactlocationoncustom
floorplandisplaymap•Lampteststandard•Pre-wireaddressabledrivermoduleintographicpanel
Auto Voice Dialers With Verification 24VDCUS-AVD2000F•4-Channel
US-AVD20001F•2-Channel
US-AVD45CF•1-Channel
•Programmablenumberoftimesmessagesrepeatedtoeachnumberdialed
•EEPROMmemorylineseizure-Compact-Easysetup•2-wayvoiceverificationallowsthepersontolistenin
-4alarmmessagezones•Callsupto8telephone,cellphone,pagernumbersper
channel
Addressable Fire Alarm PanelFL-MS9050UD•Singleloopsupportsupto50addressablepointsof
anytype• IntegratedDACTforoff-premisesmonitoringand
remoteup/download•Built-inNACsynchronizationforWheelock,Gentex,
SystemSensor•Annunciatorbussupportsupto8devices
Addressable Fire Alarm PanelFL-MS9200UDLS•SingleSLCprovidessupportfor198addressable
devicesontwisted,unshieldedfirewire•Built-indigitalcommunicatorforoff-premises
monitoringandremoteup/download•4NAC’swithbuilt-insynchronizationforGentex,
SystemSensorandWheelock•3amppowersupplyexpandableto6ampsof
notificationpower•SupportslowercostANN-BUSorLegacyACS
annunciators
Advanced Internet Fire CommunicatorFL-IPDACT2UD•FirstfirealarmIPcommunicationsmodulethatenables
completeupload/downloadcapabilitiesviaanyIPconnection
•Savesthecostoftwodedicatedphonelines.Onlythecustomer’ssharedIPequipmentisrequired.
•Requiresnochangetotheexistingpanelconfiguration.TheIPDACTconnectsdirectlytotheprimaryandsecondarytelephoneports.
• Fastalarmtransmission(lessthan10secondtransmissiontime)
Remote AnnunciatorBK-RA100Z •Designedforbothconventionalandintelligent
applications•ProvidesvisualredLEDalarmindication
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us80
Fire
Addressable Fire Alarm Control PanelSK-5820XL•Upto508addressable points•Usesstandardwire;noshieldedortwistedpairrequired•Built-indigitalcommunicator•Centralstationreportingbypointorbyzone
Addressable Controls
Single Loop Addressable Fire PanelSK-5808•Upto127addressablepoints•Usesstandardwire;noshieldedortwistedpairrequired•Built-indigitalcommunicator•Centralstationreportingbypointorbyzone•SK devices:99detectorsplus99modulesequals198
points•Alternatedevices:upto127addressablepoints
Single Loop Addressable Fire Alarm Control PanelSK-5700•Usesstandardwire;noshieldedortwistedpairrequired•Built-indigitalcommunicator•Centralstationreportingbypointorzone•SKdevices:50detectorsplus50modulesequals100
points•Alternatedevices:upto50addressablepoints
Addressable Fire Alarm PanelFL-MS9600LS•NewLiteSpeedTMcommunicationsprotocolforlightning
fastresponse•Devicesoperateonstandardunshielded“fire”wire•Upto318addressabledevicesperSLC,expandableto636•Easymountchassis•159detectors&159control/relay/monitormodulesper
SLCFL-MS9600UDLS•FeaturesaboveplusRemoteUpload/Download•Builtindigitalcommunicator
Photoelectric Smoke Detector with Thermal SensingSK-PHOTOT•135°Ffixedtemperaturethermalsensing•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•SK-B210LP6"intelligentbasewithtrimringincluded
Photoelectric Smoke DetectorSK-PHOTO•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•SK-B210LP6"intelligentbasewithtrimringincluded
Remote LED AnnunciatorSK-58653•30programmableLEDs•Fitsstandard3-or4-gangelectricalbox•Upto8annunciatorsperaddressablepanel
Remote LCD AnnunciatorSK-5860R•80-characterbacklitannunciator•Availableingrayorred•Surfaceorflush-mount
Monitor ModuleSK-MINIMON•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•Compactfootprintallowsittofitinsidedevicesorin
junctionboxesbehinddevices
Ten Input Monitor ModuleSK-MON10•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•Unusedaddressesmaybedisabled
Fault Isolator ModuleSK-ISO•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•LEDindicatorandwallplateincluded•Mountsinastandard4"junctionbox
Six Zone Interface ModuleSK-ZONE6•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•Unusedaddressesmaybedisabled
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 81
FireAddressable Controls - Commercial Fire/Intrusion Panels
Duct Smoke Detector SK-DUCT•Photoelectricdetectorheadincluded•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Flexiblehousingfootprint-squareorrectangular•Broadopeningtemperaturerange-4°Fto158°Fand
broadhumidityrange
Multi-Criteria Photoelectric DetectorSK-ACCLIMATE•135°Ffixedtemperaturethermalsensing•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•SK-B210LP6"intelligentbasewithtrimringincluded
5110XM Fire Alarm Communicator (DACT)5110XM•FivesupervisedTypeBzones•Supportsupto4keypads•Sevenbuilt-inLEDindicators•Superviseddigitaldialer• Temporalcodecompliant•Supports2-wirecompatiblesmokedetectors•Upload/downloadcapability
4-Zone Releasing Control PanelPL-PFC4410RC•4ClassBinputs•2supervisorycircuits•Allows10,000'oflinearheatdetectionperzone•19preconfiguredprograms•Dedicatedsupervisoryzone•4programmableoutputs•On-boardprogramming•40-eventhistorybuffer
Fire Alarm Control PanelPL-PFC5004E•4ClassB(StyleB)InitiatingCircuitswhichmaybe
configuredas2ClassA(StyleD)circuits.Expandableupto8ClassB(StyleB)or4ClassA(StyleD)InitiatingCircuits
• IfnoSupervisorycircuitsareenabled,theSupervisoryrelaybecomesasecondAlarm relay
•EasyconfigurationviaDIPswitches•5AmpPowerSupply•AutoSignalSilence•ZoneDisconnectSwitches
Commercial Fire Alpha Keypad6160CR-2•Programmablefunctionkeys•Built-insounder•SevenLEDs-Armed,Ready,Power,FireAlarm,Silenced
andTrouble•Largeeasy-to-readdisplayRedremovabledoor•CompatibilitywithVISTA-32FBRev.4andhigher,
VISTA-128FBRev.4andhigher,VISTA-128FBP,VISTA-250FBP
New! 25 Point Addressable Fire Alarm Control Panel SK-5600•Built-insupportforacombinationofupto25Honeywell
FireSystemsdetectorsandmodules•Built-indigitalcommunicator•Usesstandardwire–noshieldedortwistedpair
required•Autolearn“JumpStartTM”featureforeasyprogramming•CustomprogrammingcanbeperformedthroughFACP
built-inbrowser.Noprogrammingsoftwarerequired.
Looking To Save Money?Watch for ADI’s monthly sales promotions!
Let ADI Stock it for You.Power/Surge protectors, smoke emitters, relays, canned air, test equipment, door holders, training books, enclosures, protective covers, gas detection, linear heat cables, annunciators, explosion proof products, flame detectors and much more.
ADI has your fire accessory needs covered!
THINK THINK THINK THINK THINK THINK THINK FOR ALL YOUR FIRE ACCESSORY NEEDS FOR ALL YOUR FIRE ACCESSORY NEEDS FOR ALL YOUR FIRE ACCESSORY NEEDS FOR ALL YOUR FIRE ACCESSORY NEEDS FOR ALL YOUR FIRE ACCESSORY NEEDS FOR ALL YOUR FIRE ACCESSORY NEEDS FOR ALL YOUR FIRE ACCESSORY NEEDSADI
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us82
Fire
Commercial Fire/Intrusion PanelsCommercial Fire/Burglar Accessories V32FBP-9•Capacity:
Zones:8-32,Users:75,EventLog:512,Partitions:2•3expansionmethods:
*Conventional*V-PlexPollingloop(two-wire)*ULCommercialwireless
•PatentedaddressableV-Plexpollinglooptechnology•ULListedCommercialFire(UL864/NFPA)•Twoon-boardnotificationappliances(NAC)
V32FB-PAK1Kitincludes:
*VISTA-32FBcontrol*6160CR-2redalphakeypad*5140DLMdialermodule
Commercial Fire/Burglar Accessories V128FBP-9•Capacity:
Zones:8-128,Users:128,EventLog:512,Partitions:8•3expansionmethods:
*Conventional*V-PlexPollingloop(two-wire)*ULCommercialwireless•PatentedaddressableV-Plexpollinglooptechnology•ULListedCommercialFire(UL864/NFPA)•SupportsremotecontrolviatheInternet(usingAlarmNet-I)• Twoon-boardnotification(bell)circuits([email protected]@24V)•Supportspanellinking-upto8systemsorbuildingsfromacentrallocationviaVA8200•Accesscontrolintegration•CCTVintegration
V128FBP-9 Power PakV128FBP-PAK1•12VDCoperation•Kitincludes:
*VISTA-128FBPcontrol*6160CR-2redalphakeypad*5140DLMdialermodule
V128FBP-9 Power PakV128FBP-PAK2
•Kitincludes:*VISTA-128FBPcontrol*6160CR-2redalphakeypad*5140DLMdialermodule
Commercial Fire/Burglar Accessories V250FBP-9•Capacity:
Zones:8-250,Users:250,EventLog:1000,Partitions:8•3expansionmethods:
*Conventional*V-PlexPollingloop(two-wire)*ULCommercialwireless•PatentedaddressableV-Plexpollinglooptechnology•ULListedCommercialFire(UL864/NFPA)•SupportsfacilityautomationviaVA8201module•Supportspanellinking-upto8systemsorbuildingsfromacentrallocationviaVA8200•Accesscontrolintegration•CCTVintegration•24Vversionavailable(V250FBP-24)
V250FBP-9(24) Power PakV250FBP-PAK2•24VDCoperation•Kitincludes:
*VISTA-250FBP-24control/comm*6160CR-2redalphakeypad*5140DLMdialer
V250FBP9 Power PakV250FBP-PAK1•12VDCoperation•Kitincludes:
*VISTA-250FBPcontrol/comm*6160CR-2redalphakeypad*5140DLMdialermodule
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 83
FireVoice Evacuation - P/E Smoke Detectors
Voice Evac PanelsEV-EVAX25EV-EVAX50EV-EVAX100•AllEvaxPanelsincludeMic,DMR,Amplifier,Power
Supply,BatteryCharger•Speakercircuits25/70Vfieldselectable•4or8Zonesoptional•Remotemicrophonesavailable•Evac&AuxiliaryMessagesbuilt-in•4minutesmessagecapacity&optionalinputcardsfor
upto64additionalmessages
Voice Evac PanelsEV-EVAX150EV-EVAX200•AllEvaxPanelsincludeMic,DMR,Amplifier,Power
Supply,BatteryCharger•Speakercircuits25/70Vfieldselectable•8to16Zonesoptional•RemoteMicrophonesavailable•Evac&AuxiliaryMessagesbuilt-in•4Minutesmessagecapacity&optionalinputcardsfor
upto64additionalmessages•Largepowerconfigurationsupto2000Wavailable-
consultfactory
Multi-Function Voice Evac PanelWH-109929•Multi-FunctionSupervisedPaging,Messaging,
BackgroundMusicDeliveryandEmergencyVoiceEvacuationSystem
•Availablefeaturesandoptions:*40wattssupervisedaudiopower*SpeakerOutputs:25Vor70.7Vpowerlimited*Contactclosuremessageactivation
•CompatiblewithallWheelockpowersupplies,speakers,strobes,clusters
ADA
Voice Evac Control PanelFL-ACC2550•Fivecommandinputs•25WstyleYorZcircuits•25Wexpandableto50WStyleYorZcircuits•Optionalremotemicrophone
FL-ACC255025T•Firefightertelephonemodulewithkeypad
Distributed Audio Voice Evac PanelsFL-ACC2550DA•DualcircuitdistributedaudiopanelfortheFL-ACC2550•25W25VRMS,expandableto50W
FL-ACC2550DAZ•ForexpandingFL-ACC2550ZSorFL-ACC255025T
Voice Evac Control PanelFL-ACC2550ZS•25Wexpandableto50W•Uptofive12secondmessages•Audiocanbesplitinto8speakercircuits•Audiocircuitsandmessagesarecontrolledviathe
ACSseriallink
DVS+ ExpandableAN-DVS50AN-DVS100AN-DVS150AN-DVS200•25/50Wattsystemsinanexpandablepackage•50,100,150&200Wattaudiooutputcapacities•Upto20stylesY/Zzones,25or70Vrms•8alarmtones,upto14digitalmessages(30sec.each)•Zoneselective,automaticandmanual
SKE Series Voice Evacuation PanelSK-SKE450•50wattsofoutputpowerona25or70.7VRMSspeaker
circuit•Downloadablevoicemessagesviadirectconnect•DigitalmessagerepeaterbuiltintotheSKE
motherboard•DigitalSignalProcessorprocessesdigitalqualityaudio
Voice Evac Control Panel 25 & 50WAN-DVS25PAN-DVS50P•25or50Wattsofaudiooutputpower
(specifiedbypart#)•CompatiblewithallFACPs:conventionaland
addressable•Oneofthemostinstaller-friendlypanelsonthemarket• Fullfeatured,noadd-onsrequired•4StyleY/Zzones,25or70.7Vrms•4alarmtones,60secondsofdigitalmessaging•Livevoice,auxiliarypagingI/F• Integralpowersupplywithbatterycharging
320A Series 120VAC P/E Smoke AlarmsES-320A•Multi-stationsmokealarm
ES-320ACC•SmokealarmwithForm4&Crelays
ES-320ACX•Smokealarmwithtandem
•Commercial-Gradesinglestationsmokealarms•DirectreplacementforextensivelyinstalledESL320•Only120VACsmokealarmwithon-sitetroublealert
Head & Base P/E Smoke DetectorsCW-SM8712W•12-24VDCoperation•ComplieswithUL268,EN54,CNS•Optional4wireunit(CW-SM871A)•Optionalflushmountunit(CW-SM8712WF)•3yearwarranty•Dimensions:4.33"diaX1.97"H
429 Series 2-Wire Smoke DetectorsES-429CES-429CTES-429CRTES-429CST•P/Ewithreplaceableopticalchamber•Optionsinclude:
*(S)sounder,(R)auxrelay*(T)integrated,(H)isolatedheat*(E)end-of-linerelay
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us84
Fire
449 Series 4-Wire Smoke DetectorsES-449CES-449CT10PKES-449CRTES-449CST10PES-449CTE•P/Ewithreplaceableopticalchamber•Optionsinclude:
*(S)sounder,(R)auxrelay*(T)integrated,(H)isolatedheat*(E)end-of-linerelay
Smoke Detector with CleanMe®
ES-521B•2-wire,P/E,6~24VDC
ES-521BXT•2-wireP/E,6~24VDC,fixed/RORheats
•Photoelectricwithreplaceableopticalchamber•CleanMe®signalcancallifcleaningisrequired•Automaticdriftcompensation
541C Series4-Wire Self-Diagnostic Smoke DetectorES-541C10PKG•4-wire12/24VDC
ES-541CXT•4-wirewithfixed/RORheat
•Built-indriftcompensationreducesthechanceofanuisancealarm
•Fieldreplaceableopticalchambermakesservicingeasy
TS7 Series Photoelectric Smoke DetectorsES-TS72 •2-wirehead&base
ES-TS72T •2-wirehead&basewithheat
ES-TS72R •2-wirehead&basewithheat&auxiliaryrelay
ES-TS74 •4-wirehead&base
ES-TS74T •4-wirehead&basewithheat
ES-702E10PK •Optionalsmall4"base
•Head&basedesignreducesinstallation&servicingcosts•Patentedself-diagnosticsprovideon-sitemaintenancealert•Exclusivefieldreplaceableopticalchambermakesservicingasnap•Built-indriftcompensationextendsdetectorlife• Flexible2-&4-wireandauxiliaryrelaymodels•MeetsNFPA72fieldsensitivitytestingrequirementswithoutneed
forexternalmeters•Lowprofiledesignblendsintoenvironment•Small4"baseavailablewhentheultimateinaestheticswinsthejob!
P/E Smoke Detectors
700 Series Head & Base P/E Smoke DetectorsES-711U10PAKES-711UTES-721UTES-731UES-741UT•Detachablehead&basedesign•Built-indriftcompensation•Intelligentself-diagnostics•2&4-wiremodels•Basesoldseparately
710/7109 CS/LS Series Smoke AlarmsGN-9070248•120VAC(9VDCBatteryBack-upon7109/7139Models)•177CandelaADAListedStrobe•TandemCapabilities(CSModels)•Patented3-PositionTestSwitch•FormCContacts(CSModels)•9'LineCord(LSModels)•On-SiteWashingProgram
ADA
8000 Series Smoke DetectorsGN-9081233•Availablein24VDC&120VAC•Patented3-positionTestSwitch•ListedforReleasingDevice• FormA/FormCcontacts•EasyWash-onsitewashingprogram•OptionalsounderincontinuousorTemporal3•Optionalintegralorisolatedthermal• Latchingunit(non-latchingavailable)
7000 Series Photoelectric Smoke AlarmsGN-9071109•120VAC&220VACOperation•90dBAPiezoHorn•Continuous(7000Models)orTemporal3(7003Models)
Sounder•OptionalIntegralorIsolatedThermal•OptionalFormA/CContacts•TandemInterconnectCapabilities•QuickDisconnectWiringHarness•EasyWashTM-On-SiteWashingProgram
90000 Series Smoke AlarmsGN-9170004•120VAC&220VACwith9VDCbatteryback-up•90dBApiezohorn•Continuous(9000Models)orTemporal3(9003Models)
Sounder•Optionsincludeintegralorisolatedthermal•OptionalFormA/CContacts•Tandemcapabilities•Quickdisconnectwiringharness•On-Sitewashingprogram
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 85
FireP/E & Beam/Duct Detectors - Wireless/Addressable
Plug-In Smoke DetectorsBK-2151•Photodetectorhead
BK-2151T•Withthermal
•2-and4-wirebasesavailable•Requiresseparate100Seriesbase
Series 2-Wire DetectorsBK-2WBBK-2WTB•Withthermal
•Photoelectricdetectors•Driftcompensation•DualLEDindicators•Plug-inunitwithbaseatdirectwireprice•Withorwithoutthermal
GN-200/GN-300 Series Smoke AlarmsGN-9170050•120VAC(GN-200/GN-203Models)•120VACwith9VDCbatteryback-up
(GN-300/GN-303Models)•85dBAPiezoHorn•Continuous(GN-200/GN-300Models)orTemporal3
(GN-203/GN-303Models)•Pushbuttontestfeature•Quickdisconnectwireharness•On-Sitewashingprogram
Series Temporal Sounder DetectorsBK-2WTAB•2-wirewithsounder,thermal
BK-4WTAB•4-wirewithsounder,thermal
BK-4WTARB•4-wirewithsounder,thermal,FormCrelay
BK-4WITARB•4-wirewithsounder,isolatedthermal,FormCrelay
Series Form “C” Relay DetectorsBK-2WTRB•2-wirewithFormCrelay,thermal
BK-4WTRB•4-wirewithFormCrelay,thermal
Series 4-Wire DetectorsBK-4WBBK-4WTB•Withthermal
•Photoelectricdetectors•Remotemaintenancesignal•Driftcompensation•DualLEDindicators•Plug-inunitwithbaseatdirectwireprice•Withorwithoutthermal
Single-Ended Beam Smoke DetectorBK-BEAM1224•Single-endedoperation•16'to328'protectionrange•Simplealignmentwithvisualfeedback•4-wire,12/24VDCoperation•BK-BEAM1224Sintegralsensitivitytestfeature
Single-Ended Reflected Beam Smoke Detector SK-BEAM•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•Reflectorkitincluded•Range16-230feet;230-328feetwithoptionallong
rangekit
Single-Ended Reflected Beam Smoke Detector SK-BEAMT•Built-intestfeature•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•Reflectorkitincluded•Range16-230feet;230-328feetwithoptionallong
rangekit
Watertight Duct DetectorBK-D4120W•Low-flowtechnologyandNEMA4rating•Eliminatesneedforcostlyseparateenclosures•4wirephotowithauxrelay•Airflowspeedsof100to4000perminute•Broadtemperaturerange-4ºFto158ºF•UV-resistant,ULlistedhousingandcovermaterials•Broadhumidity0to95%non-condensing
Duct Smoke DetectorBK-D4120•4-wireconventional
BK-D2•2-wireconventional
• FlexibleHousingFootprint-square,rectangularoranythinginbetween
•Plug-insensorofferssuperbfalsealarmimmunityandthelatestsensortechnology
•BroadOperatingTemperatureRange-4°Fto158°Fandbroadhumidityrange(0%to95%non-condensing)
Wireless Smoke DetectorsCA-TX6010011•Self-Diagnosticsreducesthechanceofanuisance
alarm•Replaceableopticalchamber•23VLithiumbatteries•Automaticdriftcompensation• Learnmodefeaturereducesinstallationtime•Alarmsignalsenttocentralstationontest
Detectors Are IdealFor Residential ApplicationsThe National Fire Protection Association (NFPA)
reports that 2,189,500 calls to U.S. fi re departments in 2003 were nui-
sance alarms. Safeguard your customers from fi nes related to nuisance
alarms with the loop test/maintenance module (2W-MOD2). The
2W-MOD2 sends a signal to the control panel when any 2-wire i3 de-
tector on the loop requires cleaning. This will allow you to schedule a
service call to clean the detector before it false alarms.
Also, use interconnected sounders with the relay/synchroniza-
tion module (RRS-MOD) to activate all sounders on your loop when
one detector goes into alarm. And, to ensure that your system follows
the temporal-three code requirements, the
RRS-MOD will automatically synchronize your
sounders.
To learn more about i3 products from System
Sensor, call or visit your local distributor today.
Advanced Ideas from System Sensor
*Statistics from NFPA survey, 09/04.Details available at www.nfpa.org.
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 87
FireWireless/Addressable - Specialty Smoke Det. & Accessories
• EquippedwithdualLED(greenandred)statusindicators•Convenientlywiretomountingbase•Nodisassemblyrequiredformaintenance/cleaning•Availablewithintegralheatsensor(5193SDT)
V-PlexTM Addressable Smoke Detector5193SD5193SDT•Lowprofiledesign•Automaticmaintenancereporting• Simpletwo-wireinstallation• Automaticdriftcompensation
Wireless Smoke Alarms3K-12799999•RF-SM-AC(ACcurrent)
3K-09199999•RF-SM-DC(DCcurrent)• Allowforaninterconnectedsystemwithoutcostlyrewiring•ACwithDCbatterybackupunittobridgetoexisting
interconnectedsystem•DCunitsforaquickandeasilyinstalledinterconnected
system•Easyinstallationandsetup• Ionizationsensor•10yearlimitedwarranty
Wireless Smoke/Heat Detector5808W3•Dualsmokeandfixedtemperature(135°F)
heatdetector•Sendsalarm,tamper,maintenanceandbatterycondition•DualLEDsforlocalstatus•Capableofsensingapre-freezeconditioniftemperature
dropsbelow41ºF•Alsoavailable:5806W3-WirelessSmokeDetector
350 Series 120VAC with Battery Back-UpES-350•120VACwithbatterybackup
ES-350CC•120VACwithauxiliaryrelay
•BackwardcompatiblewithextensivelyinstalledESL320•Bringexistinginstallationsuptocodewithout
electricians•Only120VACsmokealarmwithon-sitetroublealert
135° F Fixed Temperature Thermal DetectorSK-HEAT•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•B210LP6"intelligentbasewithtrimringincluded
IIonization Smoke DetectorSK-ION•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•B210LP6"intelligentbasewithtrimringincluded
190° F Fixed Temperature Thermal DetectorSK-HEATHT•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•B210LP6"intelligentbasewithtrimringincluded
135° F Fixed Temperature Rate of RiseSK-HEATROR•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•DualLEDsfor360°visibility•B210LP6"intelligentbasewithtrimringincluded
Power Supervisory Relay ModuleES-2041224V•12/24VUL•ApprovedforallListed•4-wiresmokedetectors•CodeCompliantforfire&lifesafetyuse•Fitseasilyintojunctionbox•6Vor12/24Vmodelsavailable
Smoke Alarms3K-21006371•PE120EPhotoelectric
3K-21006378• i12040Ionization
• ACwithDCbatterybackup• Testbutton• Hushbuttontotemporarilysilencefalsealarms• EasyInstallation• Fewercallbacks• 10yearlimitedwarranty
Smoke! In A Can®
ES-SM20012P•Onlyfunctionaltestsystembacked-upbyGE•MeetsNFPAfunctionaltestrequirements•ecomaginationTM-“Green”aerosolprovidesvisibility•Doesnotcontaminatedetector•Evaporatescompletely
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us88
Fire
Smoke Detector Accessories2.5 oz. Smoke CheckTM Smoke Detector TesterHO-25S•Designedforfunctionaltestingofallsmokedetectors,ResidentialorCommercial,
batterypoweredorwired/wireless,singlestationorpanelinstallation,ionizationorphoto-electric
•GreatforDuctDetectors•250+testsprayspercan•UL/ULCListed•Alarmmanufacturerapproved•MeetsallNFPA72andInternationalFireCodeRequirements•SafeonSensors•Leavesnoresidue•Doesnotcontributetoglobalwarming•Ozonesafe,environmentallyfriendly•MeetsKyotoandMontrealProtocols•TheOriginal-AcceptNoImitations
Individual PartsHO-N30•30"AluminumOpenDeliveryTestHead
HO-N59•50"AluminumOpenDeliveryExtensionPole
HO-1490•18"OpenDeliveryAdapter
HO-VT1•EnclosedDeliveryTestHead
HO-VP4X•FiberglassExtensionEnclosedDeliveryExtension
HO-VP8•8',2section,TelescopingFiberglassEnclosedDeliveryExtensionPole
HO-VP16•16',4section,TelescopingFiberglassEnclosedDeliveryExtensionPole
HO-VT694•HeatDetectorTesterHeadAssembly,adaptabletoEnclosedDeliveryEquipment
HO-HDTC•ConsumableHeatPadsandSalineforHO-VT694,
includes:72HeatPadsand32SalineSachets
• 100%lifetimeguaranteeonallHSIFire&SafetyGroupproducts
CoCheck Carbon Monoxide Detector TesterHO-VTCO1•Manufactureroftheoriginalcarbonmonoxidedetector
tester-newandimprovedHO-COT97•5to10testspercan•Allnatural,usesonlymaterialsfoundintheairwe
breathe•Ozonesafe,environmentallyfriendly,doesnotcontribute
toglobalwarming•DOTApproved,ULListingandPatentPending
DustAirTM CleanerHO-DUS97•5oz.PushButtonactuated(designedforusewithVersa-Toolsequipment)
HO-DUS97T•5oz.Triggeractuatedhandheldunit-(notforusewiththeVersa-Toolsequipment)
HO-DUS9710•10oz.Triggeractuatedhandheldunit-(notforusewiththeVersa-Toolsequipment)
•DustAir,aerosoldusterforusewithallelectronicequipment.Usedtocleardebris,dustandcob-webswithoutdamagingtheelectronics.RecommendedforcleaningsmokedetectorspriortotestingwithHO-25SSmokeCheck,SmokeDetectorTester.
•Mosteconomicalairduster•Notintendedforconsumption
Complete Inspectors KitHO-VTCOMPLET•Everythingtheprofessionalinspectorneedstotestboth
smokeandheatdetectors•MaximumReach:34'•Kitincludes:
(1)HO-VT-ODOpenDeliveryTestKit(1)HO-VTED8EnclosedDeliveryTestKit(1)HO-VT694HeatDetectorHeadAssembly(1)HO-VP1616'TelescopingFiberglassExtensionPole(1)HO-VP4X4'FiberglassExtension(1)EquipmentCarryingBag
Enclosed Delivery Test EquipmentHO-VTED8H•AneconomicalequipmentkitforbothSmokeand
HeatDetectorTesting•MaximumReach:24'•KitIncludes:
(1)HO-ED88'EnclosedDeliveryTestKit(1)HO-VT694HeatDetectorHeadAssembly(1)HO-VPAdapter(1)EquipmentCarryingBag
•ConsumableHeatPadsandsaline(reorderHO-HDTC)
Enclosed Delivery Test KitHO-VTED16•AneconomicalequipmentkitforbothSmokeand
HeatDetectorTesting•MaximumReach:24'•KitIncludes:
(1)HO-ED1616'EnclosedDeliveryTestKit(1)HO-VT694HeatDetectorHeadAssembly(1)HO-VPAdapter(1)EquipmentCarryingBag
•ConsumableHeatPadsandsaline(reorderHO-HDTC)
The OriginalaerOsOl adapTer...
HO-1490fOr Open delivery TesTing
Since 1994
For Use...By Hand
With professional extension tools
The HO-1490™ 18” (45.72cm) Adapter reduces cost per test while controlling the tendency to overspray and maintaining the aerosol at an appropriate distance from detector preventing aerosol residue.
1994 Innovative Original Design UL Listed since 1994 Designed to be reusable Approved by all Detector Manufacturers for more than a decade Designed to work for testing by hand or with professional tools and extension poles 100% Life Time Guarantee
••••
•
•
Product Benefits:
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us90
Fire
Smoke Detector Accessories Open Delivery Testing EquipmentHO-VTOD•OpenDeliverySmokeDetectorTestingEquipment•MaximumReach:34Feet•Kitincludes:
(1)HO-1490Adapter(1)HO-N3030"OpenDeliveryHead(1)HO-N5950"ExtensionPole
•OpenDeliveryTestingsimulatestherisingeffectofrealsmokeassociatedwithfire•Upto(5)HO-N59Extensionscanbeconnected•Recommendedforuseinareaswhereairflowdoesnotneedtoberestricted;
suchas;warehouses,multi-storyatriums,privateresidences•DesignedwithSafetyinMind;Noladders,Noclimbing,Noreachingaroundobstacles•Availableinoneconvenientequipmentcarryingbag•ProfessionalEquipmentDesignedforyoureveryneed
Enclosed Delivery Testing EquipmentHO-VTED8•8footEnclosedDeliveryTestingEquipment•MaximumReach:24feet•Kitincludes:
(1)HO-VT1EnclosedDeliveryTestHead(1)HO-VP88footTelescopingFiberglassPole
•EnclosedDeliverytestingisolatestestingsprayfromgeneralairflow•Recommendedforuseinareaswhereairflowmustberestricted,
suchas:hospitalsandcleanrooms•DesignedwithSafetyinMind;Noladders,Noclimbing,Noreachingaroundobstacles•Availableinoneconvenientequipmentcarryingbag•ProfessionalEquipmentDesignedforyoureveryneed
Heat Detector TesterHO-VT6948•8footHeatDetectorTestingEquipment•MaximumReach:24feet•Kitincludes:
(1)HO-VT694HeatDetectorHeadAssembly(1)HO-VP88footTelescopingFiberglassPole(12)HeatPadsand(6)SalineSachets
•AnInstantHeatSourcewithoutbatteriesorelectricalcords•Non-Toxic,EnvironmentallySafe•Availableinoneconvenientequipmentcarryingbag•HeatPadsandSalineavailableforrestocking,(HO-HDTC)•ProfessionalEquipmentDesignedforyoureveryneed
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 91
FireSmoke Detector Accessories
HSI IS PROUD TO BE GREENHO-25SWiththerisingcalltoenvironmentalconscientiousness,HSIisproudtobeabletosay;weareawareoftheerosivevalueofsomechemicalsonouratmosphere.OurHO-25SSmokeCheck,SmokeDetectorTesterhasNOHFC,NOCFC,doesnotcontributetoglobalwarmingortoozonedepletion.WehavebeenGreensince1979,beforeitwaspopulartobegreen,beforeitwasinthenetworknewseveryday,whenitwasfirstULListed.
*NOHFC,NOCFC*100%OZONESAFE*DOESNOTCONTRIBUTETOGLOBALWARMING.
SmokeCheckTMSmokeDetectorTesterisandalwayshasbeenEnvironmentallySafe
Enclosed Delivery Smoke & Heat TesterHO-VTED16H•Aneconomicalequipmentkitforbothsmokeand
heatdetectortesting•Maximumreach:24'•KitIncludes:
(1)HO-ED1616'EnclosedDeliveryTestKit(1)HO-VT694HeatDetectorHeadAssembly(1)HO-VPAdapter(1)EquipmentCarryingBag
•ConsumableHeatPadsandsaline(reorderHO-HDTC)
Professional Inspector Test KitHO-VTKIT1•Everythingtheprofessionalinspectorneedstotest
smokedetectorsinanyenvironment•MaximumReach:24'•Kitincludes:
(1)HO-VT1EnclosedDeliveryTestHead(1)HO-VP1616'TelescopingFiberglassExtensionPole(1)HO-VP4X4'Fiberglassextension1)EquipmentCarryingBag
•Encloseddeliveryisolatestestsprayfromgeneralairflow
Smoke/CO Alarm Relays3K-SM120X •SmokeRelay
3K-CO120X •CORelay•120VAC,0.08A•ActivatesonsignalfrominterconnectedsmokeandCO
alarms•Usetoactivateauxiliarydevicessuchasbells,sirens,
lighting,orsysteminputs
Pulse Load Battery Tester2S-CELL01•Extremelyaccuratetestofthebattery’sperformance•Testsabilitytodelivercurrent&maintainvoltageunder
load• Identifiesweakorfailingbatteries•Quicktesttime,15-20seconds•Additionalitems:
2S-CELL01-Pulseloadbatterytesteronly2S-CELL01CS-Paddedcase
Sound Level Meter2S-DB01•ANSIS1.4Type2(requiredbyNFPA)•TwoweightedSoundPressurelevelsAandC
Duct Detector Tester2S-DUCT01•Acceptedtestdeviceforannualtestingofpressure
andairsamplingabilityofductdetectors• Includeshardcaseandsamplingtubeplugs
Smoke Detector Sensitivity Tester2S-TRUTEST80•Universalandportableunit•Manufacturerapproved•Readingmeasured&readin%perfootforeasy
documentation• Includes:
(1)2S-SOLO100 -15'Telescopicpole(1)2S-TRUTEST801-Smokedetectorsensitivitytesterunitwithcase(1)Case/122S-SMOKE400aerosolcans
808 Starter Smoke Test Kit2S-SOLO808•Testssmokedetectorsupto12'professionally•Economical&efficienttestmethod•Mostbangforthebuck!• Includes:
(1)2S-SOLO108-8'telescopicpole(1)2S-SOLO330-Smokedispenser(1)2S-SOLO602-Starterkitbag(1)Canof2S-SOLOA4AERaerosol
461 Starter Smoke Test Kit2S-SOLO461•Cordless•TestSpottype,ROR&combinationdetectors•Heatupto194°F•Activates95%ofallheatdetectorswithinseconds• Includes:
(1)2S-SOLO460-Heatdetectortester(2)2S-SOLO760-NiMhbatterybatons(1)2S-SOLO725-Fastbatterycharger
851 Smoke/Heat/CO Test Kit2S-SOLO851KT•Professionallytest&removedetectorsupto24'• Includes:
(1)2S-SOLO10015'Telescopicpole(1)2S-SOLO1014'Fixedextensionpole(1)2S-SOLO200Removal/replacementtool(1)2S-SOLO330Smokedispenser(1)2S-SOLO461Heatdetectortestkit(1)2S-SOLO610Technicianbag
•Additionalkits:2S-SOLO850KT(w/out2S-SOLO461)
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 93
FireSmoke Detector Accessories
330 Smoke Dispenser2S-SOLO330•Testalltypesofsmokedetectors•Ruggedanddurableforeverydayuse•Professionalandpreferredmethodoftesting•Encloseddeliveryconservesaerosol• LifetimeWarranty• “Theoriginalsmokedetectordispenser,everythingelse
isinconsequential”
A4 Smoke Detector Aerosol2S-SOLOA4AER• Theonlynonflammablesmokeonthemarket•10ozcansyields500+tests•Economicalaerosolusage•ForusewithSolo330•ULListedandManufacturerapproved
3 oz Smoke Detector Tester2S-SABRE•UniqueFlick’nTestaction•Suitableforuseonionizationandphotoelectricdetectors•3ozcandeliversmoreteststhenanyotherhandhelddetectortester• Fasterdetectoractivationandclearing•Sabredesigneliminatesharmfulresidue•Siliconefree-eliminatesdetectorcontamination•Eco-friendly-theonlydetectortesterwithaunique100%bio-degradable‘sabre’•OzoneFriendlywithnoCFC’s•LOWESTCOSTPERTEST•Approvedbymajormanufacturer’s•ULListed•Thenewkidontheblock-cuttingedge,fast,efficient.Whybe“original”whenyoucanbe
thiscool!
C6 Carbon Monoxide Detector Tester 2S-SOLOC6•SafetouseCOgasdetectortester•Suitsdetectorswithspeeduptestmode•Non-flammablemixtureofcompressedgas•OnlygasapprovedforusewithSystemSensor’s1224T
COdetector
•ManufacturerEndorsed•150testspercan•Smalllightweighteasytousecanister-
NONEEDFORDISPENSER!
Dual Monitor ModuleSK-MONITOR2•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•LEDindicatorandwallplateincluded•Mountsinstandard4"junctionbox
Monitor ModuleSK-MONITOR•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•LEDindicatorandwallplateincluded•Mountsinstandard4"junctionbox
Zone Interface ModuleSK-ZONE•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•LEDindicatorandwallplateincluded•Mountsinstandard4"junctionbox
Supervised Control ModuleSK-CONTROL•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•LEDindicatorandwallplateincluded•Mountsinstandard4"junctionbox
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us94
Fire
Smoke Detector Accessories - Initiation Devices
Series Sensitivity ReaderBK-SENSRDR•Fori3Seriesdetectors• Infraredreader•Novoltmeterrequired•Outputs%perfoot&textmessage•Handheldorconnecttopole
Series AccessoriesBK-RRSMOD•Reversespowertoi3Seriessoundermodels•Synchronizesi3sounders
BK-RT•Removaltool-handheldorpolemount
BK-A77AB2•Retrofitadaptorbracket
Non-Flammable Smoke Alarm TesterT8-191425S•Testphotoelectric&ionizationdetectors•Non-flammable•Verticalactuatorspraysupto7feet•Quicklysoundsalarm•Non-ozonedepleting•Safeonplastics
Six Relay Control ModuleSK-RELAY6•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels• (6)3AmpformCrelayoutputs•Rotaryaddressswitch•Unusedaddressesmaybedisabled
Relay Control ModuleSK-RELAY•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels• (2)3AmpformCrelayoutputs•Rotaryaddressswitch•LEDindicatorandwallplateincluded•Mountsinstandard4"junctionbox
Six Circuit Supervised Control ModuleSK-CONTROL6•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•Rotaryaddressswitch•Unusedaddressesmaybedisabled
Plug-Type Supervisory SwitchPL-PTSC•Designedtosupervisesprinklersystemvalvesandalso
maybeusedtosecureotherapplications•Non-corrosivecompositematerial•NEMA6Pratedenclosurewhenproperelectricalfittings
areused•UL&CULlisted
PS Series Pressure & Waterflow SwitchesPL-PS10•NEMA4solidmetalenclosure•Two1/2"knockoutsfordualvoltageapplications•SeparateisolatedwiringchamberseliminateNEC
questionsregardingmulti-voltageapplications•5-yearwarranty
PL-PS40•10-60PSIpressurerange
PL-PS120•2contacts
Supervisory SwitchesPL-OSYSUPL-PCVS
•Availablewithoneortwocontacts•NEMA6Prating(submersible)• Foroutsidestem&yoke(OS&Y)valves•Adjustablebrackets(OS&Y)• Fitsvalves1/2"to12"(OS&Y)• Foryardorwalltypepostindicatorvalves(PCVS)• Forbutterflyvalves(PCVS)•Removable1/2"malenipple
formounting(PCVS)
Retrofit Ball Valve SwitchPL-RBVS•Perfectforbackflowpreventors1"-2"•Fitsvirtuallyany1/2"-2"ballvalve•Optionalcovertamperswitch•NEMA4ratedenclosureforindoor/outdooruse•Patentpending
ADA
VSR Vane Type Waterflow Switch with RetardPL-VSR•2"-10"steelpipe•Schedules10-40•Non-corrosivesleevefactoryinstalledinsaddle•450PSIservicepressure•TwosetsofSPDT,FormCcontacts•NEMA-4/IP54ratedenclosure•Temperaturerange:40°Cto120°C
Small Pipe Vane Type with RetardPL-VSRS•For1"-2"steel,copper,orplasticpipe•Standardpaddlesfor1"-2",threadedandsweattees;
1"-1-1/2"CPVCtees•Adjustableinstantlyrecyclingpneumaticretard
PL-VSRSGST•FitsCPVCpipesizes1"thru2"•Specialfittingallowsforinstallationinconfinedspaces
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 95
FireInitiation Devices - Flame Detectors
OSY2 Supervisory SwitchBK-OSY2•ForOS&Yvalves•1-pieceadjustablemountingbracket•Singlesideentryforconduit•2SPDT(FormC)contacts•Adjustableactuator•3yearwarranty
Control Valve Supervisory SwitchBK-PIBV2•Forpostindicator&butterflyvalves•Bi-directionalactuatorforrising&fallingflags•2SPDT(FormC)contacts•Adjustablelengthactuator•3yearwarranty
EPS Series Pressure SwitchesBK-EPS402•Foruseondry,pre-actionanddelugesystems
orwetsystemswithalarmcheckvalve•Alarmpressureswitchandsupervisorypressureswitch
modelsavailable•3pressuresettings-6modelsavailable•3yearwarranty
Plug-In Type Supervisory SwitchBK-PSP1•Fornon-risingstemgateandball&anglevalves•360°mountingbracketinstallseasily•Adjustablelengthsupervisorycord•Covertamperswitchincluded•3yearwarranty
WFD Series Waterflow DetectorsBK-WFD40•2"through8"steelpipes•NEMA4,450psirated•Vanetypewaterflowswitch• Indoor/outdooruse•Visualswitchactivation•3yearwarranty
Explosion Proof Waterflow DevicesBK-WFD40EXPBK-EPS40EXPBK-OSYEXPBK-PIBEXP•WFD2"through8"models•3EPSmodelsavailable•3yearwarranty
T-Tap Waterflow DetectorsBK-WFDT•StandardT-tap
BK-WFDTH•Forresidentialapplications
•Paddlesfor1",1.25",1.5",and2"ferrousandcoppersweats,1"CPVCtee
•Forresidentialsystems&branchlinesignaling•1"NPTconnection•3yearwarranty
Fire Door Concealed ContactUS-260•Upto.675"Gap•3/8"x5/8"•ClosedCircuit•24"Leads•ApprovedbyCAFireMarshalforfiredoors
*675"Gap*3/8"x5/8"Size–PrecisionMachinedMetals*100MillionLifeCycleOperation*LightningResistant1.0AmpContacts*24"Leads*ClosedCircuit,SPDT,OC
• OneTurnLocks,OneTurnRemovesforTests
DETECT-A-FIRE®
Detection & Release DevicesFN-12000 Series•Reliable,auto-reset,fieldtestable•Rugged;withstandsshockandvibration•Versatile;offersvarioustemperaturesettings•Factorysetandtheinternalcontactareaishermetically
sealedinstainlesssteel
Wireless Rate-of-Rise Fixed Temperature Heat Detector5809•Providesrate-of-riseheatnotification(when
temperaturerisesmorethan15°Fperminute)•Providesfixedtemperaturedetection(tripsat>135°F)•Requires5881seriesreceiver•ULListedforuseincommercial/residentialapplications
Thermal DetectorBK-5451•Electronicheatdetection•Provides135°Ffixedtempalarm,pointandrate-of-rise
thermalsensor•Varietyofmountingbases•3yearwarranty
5600 Series Mechanical Heat DetectorsBK-5601P•135°FFixed/ROR
BK-5602•194°FFixed/ROR
BK-5603•135°FFixed
BK-5604•194°FFixed
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us96
Fire
Flame Detectors - Gas DetectorsFlame SensorPU-FS2000E•33'x120°detectionpattern•10to30VDC•Adjustablesensorhead•Detectsultravioletraysinflame•Selectabledetectiontimer:0.2second,1second,6
second,30second•AlarmForm“C”,Tamper&AlarmMemory•AlarmsounderwithOn/Offswitch•5yearreplacementwarranty
PU-FS1000,PU-FS3000,PU-FS5000&PU-FS6000arealsoavailable
Macurco CM-15/15A Gas DetectorMA-CM15MA-CM15A•ULListedtoUL2075•12-24VACorDCinput•SPDTrelay-workswithN.O.orN.C.circuit• Troublesignal•Buzzer(MA-CM15Aonly)• Flushmountsovera4x4or2gangelectricalbox•Lowmaintenanceandlonglastingsensortechnology
Carbon Monoxide Macurco CM-E1 Gas DetectorMA-CME1•ULListedtoUL2075,testedtoUL2034•9-32VACinput•Workswithfireorburglaralarmsystems•SPDTrelay-workswithN.O.orN.C.circuit•Simple3stepSpeedMountinstallation•Sleek,compactdesignwithflushmountconfiguration•Troublesignal•Patented3MEZ-CheckTechnologyforquickand
convenienton-siteCOtesting
Carbon Monoxide 9V AlarmQN-9SIR•9-voltbatteryoperation•85dBsounder•UL2034listed•UniversalMountingPlate-wallorceilingmount•UsedwithFireandSecuritycontrolpanels•6yearlimitedwarranty
Carbon Monoxide System DetectorQN-1224SIR•12or24VDCinput•60microampsstandby•Alarm&Troublesignalrelays•UL2075listed•UniversalMountingPlate-wallorceilingmount•UsedwithFireandSecuritycontrolpanels
SafeAirTM Carbon Monoxide DetectorES-250CO•NextgenerationtothemostwidelyinstalledES-240COE
COdetector• Long-lifesix-yearsensor•Built-introublerelay• FullyListedtotheUL2075Standard•12or24VDCoperation•AdapterplatemakesreplacingES-240COECOdetector
simple•SKU#ES-250COPLT5PKG
Wireless Carbon Monoxide Detector5800CO•Sendsalarm,trouble,tamperandbatterycondition• EquippedwithdualLED(greenandred)statusindicators•Generatestemporal4patternaudiblewarninginan
alarmcondition•Surface-mounttowallorceiling• Includes3Vlithiumbattery•UL2075listed,COsensitivityisevaluatedonUL2034
CO1209GN-9180009•120VACwith9VDCback-up•Electrochemicalsensor•Pushbuttonfunctionaltest•Endoflifesignal• Lowormissingbatteryindicator•Relaymodelavailable,relaysfunctiononbattery
back-up•Hornfrequency3100Hz,Temporal4soundingpattern•Quickdisconnectwireharness
GN-503 Series Combination Smoke/CO AlarmGN-9180005•120VACwith9VDCBatteryBack-Up•CombinationPhotoelectricSmokeandElectrochemical
COAlarm•PushButtonFunctionalTest•EndofLifeSignalforCOSensor•LoworMissingBatteryIndicator•RelayModelAvailable,RelaysFunctiononBattery
Back-Up•Temporal3SounderforSmokeAnnunciation
E3 PointH8-E3SCOE3Point=EfficientOperations+EnergySavings+EconomicalValue•ToxicandCombustibleGasMonitorforall Commercial
BuildingAreas•Standaloneorstandalonewithremote(dualgas)
operation•DetectsCarbonMonoxide(CO),NitrogenDioxide(NO2),
Oxygen(O2),Hydrogen(H2),HydrogenSulfide(H2S),Methane(CH4)andPropane(C3H8)
•Plug-n-playsensor•85dbhorn&2DPDTrelaysincluded
Carbon Monoxide Alarms (CO)3K-21006406 •AC/DCpoweredCO
3K-9000146004 •DCpoweredCOwithDigitalDisplay
3K-21006377 •AC/DCpoweredSmoke/COcomboalarm
•NighthawkCOtechnologyoffers40%longerlife•Hardwireunitscanbeinterconnectedandcomewith
easytousewiringharness•Comboalarmhelpsprotectagainst
bothsmokeandCO•7yearlife
Carbon Monoxide Detector KitLN-DXCOKIT •ThekitisdesignedtoprovidewirelessCOdetection
capabilityforANYhardwiredalarmcontrolpanel•Kitcontains;
*(1)LN-DXS80carbonmonoxidealarmand*(1)LN-DXR7022-channelreceiver
•TheLN-DXS80providesawarningtoalertagainstboththeacuteandchroniceffectsofcarbonmonoxide(CO)poisoning
•TheLN-DXR702providesForm“C”relayoutputsforconnectiontoanalarmcontrolpanel
•RFfrequency:315MHz
The original wave of system-connected carbon monoxide
(CO) detectors have reached their end-of-life. Every day more
aged detectors require replacement. This is a huge opportunity for
you to gain recurring monthly revenues and obtain new product
sales through CO detector retrofits. Upgrade to the award-winning
CO1224T with RealTest™ and get these benefits:
No costly system upgrades or installation hassles — The CO1224T
requires low current draw, provides 12/24 volt operation, and offers several mounting options
with ample room for wiring.
Full compliance with NFPA 720: 2009 — RealTest is the first and only functional test that
quickly verifies that the CO cell is functioning using a short spray of canned CO.
Proactive service calls — A six-year end-of-life
notification alerts the central station at the end of
the detector’s functional life span, enabling you to
proactively meet customer needs.
Go to systemsensor.com/co to learn more.
Time for a Change
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us98
Fire
Gas Detectors - Pull StationsCarbon Monoxide DetectorBK-CO1224T•RealTestTMtechnologyallowsforfunctionaltestingin
thefield•Troublerelayforcircuittroubleordetectorendoflife•Provideswiringsupervision•4-wiredetector;mountstowallorceiling•Mostreliablesensingtechnologyintheindustry
Manual Pull StationFD-4050001T•Singleactionoperation•4-wirepigtailconnection•Rigidmetalconstruction•Surfacemountingorsemi-flushmounting
usinganoptionalbackbox•Non-coded•FD-4050211Toffersterminalconnections
Explosion Proof Pull StationFD-MPEX•2-stepactivation•Listedforhazardousandexplosion-proofatmospheres•Rugged,corrosionresistantcastaluminumhousing•Universalone(1)N/Oorone(1)N/Ccontact•NEMA7CS,9EFG•ClassI,Div.1and2GroupCandD•ClassII,Div.1and2GroupE,F,andG•ClassIIIHazardouslocations
Wireless Carbon Momoxide DetectorVS-MCT442•PowerCodecompatiblewirelessdetector• Fullysupervisedwithselfandmanualtesting•Loudbuilt-inalarmbuzzer(95db)withvisualLEDalarm
Gas DetectorDW-GHD200012UL•12VDC,UL•24VAC/DC&110VAC•Naturalgas,propane,butane•Longlifeelectronicsensor•Normallyopenrelayoutput
Fire-Lite Pull StationFL-BG8•Aluminumdie-formed•Wireleads,SPST•Singleaction,keyreset•ADAcompliant•18monthwarranty
Versatile 4x4 Box for Power or Low Voltage9N-FSR404S•Platedsteel,alsoavailableinredsteel
(9N-FSR404SRD)9N-FSR404RD•Redplastic
9N-FSR404BL•Blackplastic
• Forretrofitprojectsor“oldwork”•Screwlocationsfor4x4and2-gangdeviceboxes-ideal
forfirealarmorsignalingdeviceinstallations•Adjustabletofitwallsfrom1/4"tomorethan1-1/2"
thick
Arlington
Outdoor Manual Pull StationFL-BG12LAOB•Dualactionoperation•Listedforoutdoorapplications•Approvedbackbox(FL-SBIO)included•Modelwithoutbackbox
FL-BG12LAO•ListedforusewithFL-WBB,FL-WP10orFL-SBIO
Manual Pull StationFL-BG12•Dual&singleactionwithhexorkeylockmodels
available•Non-codedmanualpullstations•MeetsADA5lb.maxpullforce•Providesmanualalarminitiatinginputsignal
Spanish Pull StationFL-BG12LSP•Spanish/English“Fuego/Fire”•Capturescrewterminalswireready•Dualactionoperation•1/4-Turnkeylock/unlock
Addressable Pull StationFL-BG12LX•Addressablemanualpullstation
(addressableinterfacemountedinsidepullstation)•Capturescrewterminalswire-ready•UsewithFire-LiteaddressableFACP’s•Dual-actionoperation
Single Action Manual Pull StationFL-BG12SL•Singleactionoperation•Keylock/reset•Wireleads,SPSTswitch•ADAcompliant
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 99
FirePull Stations
Metal Pull StationsES-10321 •Singleaction(DPST)withhexreset
ES-10322 •Dualaction(SPST)withhexreset
ES-10342 •Dualaction(SPST)withkeyreset
ES-10360 •Weatherproofpullstation
•Single&dualactionpullstations•Terminalorflyingleads•Semi-flushorsurfacemount
ADA
Relocator for Pull StationLE-RELOCATOR•TheRELOCATORisdesignedtolowertheheightofapull
stationtomeettheADAheightrequirement
Specialty Push Button StationsFL-FSS SERIES•Labeled-Evacuation(yellow),Emergency(blue)&
Exit(green)•Key-reset,momentaryswitchandPush/Turnrelease•Availablewithorwithoutacover• Idealforavarietyofnon-fireapplications
ADA
SPECTRUM Special Application Pull StationAN-SG32CXK2R•SingleAction
AN-SG32CXK1•Dualaction
•Rugged,butlightweight,die-castmetalalloyconstruction
•Variouscolor/labelcombinationstosatisfyspecialapplicationrequirements* i.e.weatheralerts,medicalemergencies,door
release,firesuppression,etc.•Colormatchedsurfaceorweather-proofbackbox
ADA
Explosion-Proof Pull StationAN-SGX32SK2S•SingleAction
AN-SGX32SK1•DualAction
•ULListedandFMApprovedforClassI,IIandIII•MarineandNEMAType4XRatedforhighlycorrosive
environments•Die-castmetal,DPDTwithterminalconnectors•Specialcolorsandapplicationlabelsavailablefor
non-fireuse•Stainlesssteeloptions
available
Manual Pull StationsPL-P32 SeriesPL-RMS Series•SingleorDualAction•Terminalconnectors•10AmpSnapActionSwitch•Customtext•Mountsonstandardsinglegangbox•Optionalauxiliarycontacts•High-glossredenamelfinish•Weather-proofandexplosion-proofavailable•MadeintheU.S.A.
Manual Dual Action PullSK-PSDALOB•Outdooruselisting•Dualactionwithkeybox•MeetsADA5lb.maxpullforce•Resetswithsamekeyaspanelenclosures
ADA
Conventional Dual Action Pull StationSK-PSDAH•Costeffective•MadeofdurableLexan•HexKeyReset•Screwterminalconnections
ADA
Manual Dual Action Pull StationSK-PSDA•Dualactionwithkeylock•MeetsADA5lb.maxpullforce•Resetswithsamekeyaspanelenclosures
ADA
Manual Single Action Pull StationSK-PSSA•Singleactionwithkeylock•MeetsADA5lb.maxpullforce•Resetwithsamekeyaspanelenclosures
Dual Action Pull StationSK-PULLDA•Keylockreset•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•LEDindicatorvisiblethroughpullstationhandle•Rotaryaddressswitch
ADA
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us100
Fire
Pull Stations - Notification Appliances
Motor Bells/Vibrating BellsWH-103942•6"MotorBell,12VDC-red
WH-103941•6"MotorBell,24VDC-red
WH-103944•10"MotorBell,12VDC-red
WH-103943•10"MotorBell,24VDC-red
WH-101627•6"VibratingBell,115VAC-red
Explosion Proof HornFD-FHEX24SMR•24VDCoperation•Louddistincttone•NEMA4Xrated•Corrosionresistantcastaluminum•ULSoundpressurelevel94dBat10feet• Firelistedforhazardous/explosion-proofatmospheres
Amplified SpeakersFD-ASHP24SMRFD-ASHX24SMRFD-UTC•Stand-alone24VDCoperationusingtonecard(single
toneapplication)-FD-UTCrequiredfortonefunction•HighdBoutputforcoverageoflarge,highnoiseareas•CompatiblewithPowertone,Voice,&otheraudio
systemswithconnectorcard• FD-ASHP24SMRavailablewithV1971strobesratedat
15/75,30/75,75,and110CD•FD-ASHX24SMRratedforhazardous/
explosion-proofatmospheres
Explosion Proof Strobe LightFD-LSEX24WMC•Ruggedcastironhousingandglobeguard•Lowcurrentdraw-500mA•Wallorceilingmountavailable•Clearoroptionalredlensavailable•1/2inchconduitopenings•15Candelaoutput• Largeblackboxforeasyinstallation
Fire Alarm BellGN-9041278•Availablein24VDCor120VAC•Availablein6"or10"housing•4-wireoperation•Mountsto4"squareelectricalbox•18AWGwireleads•OutdoorListedwhenusedwithGentexGBBBBackBox
SSPKCLP SpeakerGN-9041445•25or70.7VRMs•Fieldselectablepowertaps:1/8,1/4,1/2,1,2or4
watts• FrequencyRange:400-4000Hz•Usedforceilingorwallmountapplications•Mountstoa4"x21/8"squaredeepbackbox•Faceplatesavailableinredorwhite
GX91/GX93 Mini-HornsGN-9041274•Fieldselectable12VDCor24VDCoperation•HornFrequencyof3100Hz•TerminalBlocks(12-18AWG)•ContinuousTone(GX91Models)• FieldSelectable:
ContinuousorTemporal3Tone(GN-GX93Models)•GN-GX93modelshaveSynchronizationCapabilities•Faceplateavailableinredorwhite
Remote Mini-HornPL-MH1224•4-wireleads
PL-MH1224T•TerminalStripModel
•Soundoutput97dB•Singlegangplate•12-24VDCand120VAC•15mAcurrentdraw•ULandcULlisted
Single Action Pull Station with Key LockSK-PULLSA•CompatiblewithSilentKnight®IntelliKnight®
addressablefirecontrolpanels•LEDindicatorvisiblethroughpullstationhandle•Rotaryaddressswitch
ADA
Mass Notification AppliancesPL-CSL1224PL-CSH1224PL-CSH24CPL-CSL24CPL-CSS Series
•Amber,blue,redorgreenlens•AllstrobeslistedtoUL1638• Indoororoutdoor•Wallorceilingmount(PL-CSH24C,PL-CSL24C,
PL-CSSSeries)
Self-Amplified SpeakerAN-DVS511•24VDC,PolarityProtected•ListedforLifeSafety/FireAlarmuse
AN-DVS512•120VAC,GeneralSignaling• ListedforGeneralSignalingapplications
•15Wattaudiooutput,25or70.7Vrms•108dBA@10feet• LowNAClineload(0.064W)•Clear,penetratingvoicetransmissions•Castaluminumforindoorandoutdooruse
Advanced Weatherproof PlatesBK-WTPBK-WTPW•Flushmountoutdoorplateforhorns,strobesandhorn/
strobesBK-WTPSPBK-WTPSPW•Flushmountoutdoorplatesforspeakerandspeaker/
strobes
•EspeciallyforusewithSpectrAlertAdvance-Routdoorreplacementmodels
•NEMA3Rrated
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 101
FireNotification Appliances - Sounder/Strobes
Alarm BellsBK-SSM246•6"diameter-24V
BK-SSM2410•10"diameter-24V
BK-SSV1206•6"diameter-120V
BK-SSV12010•10"diameter-120V
•8"alsoavailable
Wall Mount Mini HornBK-MHR•Red
BK-MHW•White
•12or24voltoperation•High&lowvolumesettings•Temporalorcontinuoustones•Abletobesynchronized
Outdoor SpeakersBK-SPWKBK-SPRKBK-SPCWK/WHK• -40°Fto151°Ftemperaturerange•NEMA4Xrated•Plasticweatherproofbackboxincluded•Wallmountavailableinredorwhite• .25or70.7VRMS
SpeakersBK-SPWBK-SPRBK-SPCWBK-SPCR•Plug-indesign•4selectabletaps(1/4to2watts)•25or70.7VRMS•Redorwhite
SpeakersBK-SPWVBK-SPRVBK-SPCWVBK-SPCRV•HighdBoutput•Plug-indesign•4selectabletaps(1/4to2watts)•25or70.7VRMS•Redorwhite
Weatherproof Horns & StrobesWH-127416 •SeriesAHHorn,24VDC,Red
WH-125023 •SeriesMTMultitoneHorn
WH-129013 •SeriesRSSWPWeatherproofStrobe
WH-128420 •SeriesMTWPWeatherproofMultitoneStrobe•Checkmanufacturersguideforbackbox
requirementsADA
Wall Mount HornsBK-HR•Red
BK-HW•White
•88dBA@16VDC•12&24VDC/FWR•3volumesettings•Mountstosingle/doublegang,4"x4"and4"octagonal
boxes
Outdoor HornsBK-HRK• -40°to151°Ftemperaturerange•88dBAhorn@16VDC•12&24VDC/FWR•3volumesettings•Outdoorbackboxincluded
ADA
ExcederTM Horn Strobes & HornsWH-STWC WH-HNWC WH-HSWC •CeilingMount•8CandelaSettings:15/30/60/75/95/115/150/177•12/24VDC,3AudibleSettings(90,95,99)•UniversalMountingBasemountsto5backboxtypes•Contactcoverprovidesprotectionandallowsforpre-
wiretestingandtroubleshooting
Series MIZ Mini HornWH-MIZ24SR•Highsoundoutputminihorn•24VDC,wallmount•ContinuousorCode3Output•Mounttosinglegangboxes
ADA
ExcederTM Horn Strobes & HornsWH-HSR WH-HNR WH-STR •WallMount• FingerSlideSwitches,VoltageTestPoints•12/24VDC,3AudibleSettings(90,95,99)•8CandelaSettings:15/1575/30/75/95/110/135/185•UniversalMountingBasemountsto5backboxtypes•Contactcoverprovidesprotection
andallowsforpre-wiretestingandtroubleshooting
Commander4 GC SeriesGN-9041209•24VDCStrobeandHorn/Strobe•Nowwith30%currentdrawreduction!•TamperproofFieldSelectableCandelas:
15,30,75,95,115&150•SuperSlideTMFeature-TestforSupervision•CheckmateTMFeature-InstantVoltageVerification•FieldSelectableTones:Temporal3orContinuous
ADA
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us102
Fire
Sounder/Strobes - StrobesWGE Outdoor SeriesGN-9041217•24VDCStrobeandHorn/Strobe•ShippedasKitwithStrobeorHorn/Strobeand
GOEorGOELPenclosure•Fixed75candelaunit•SuperSlideTMfeature-testforsupervision•CheckmateTMfeature-instantvoltageverification
ADA
Commander3 GE3 SeriesGN-9041317•12VDCor24VDChorn,strobesand
horn/strobes•Nowwith30%currentdrawreduction!•Tamperprooffieldselectablecandela:
15,30,60,75&110(24VDConly)•SuperSlideTMFeature-TestforSupervision•CheckmateTMFeature-InstantVoltageVerification•FieldSelectableTones:
Temporal3,Continuous,Chime&Whoop
ADA
ADA
Commander2 GE SeriesGN-9041127•24VDCHorn,StrobeandHorn/Strobe•FixedCandelaOptions:
15,30,60,75,110,177&15/75•SuperSlideTMFeature-TestforSupervision•CheckmateTMFeature-InstantVoltageVerification•FieldSelectableTones-
Temporal3,Continuous,Chime&Whoop
Ceiling Horn/StrobesBK-PC2R/RPBK-PC2RHBK-PC2W/WPBK-PC2WH/WHP•2-wire
BK-PC4RBK-PC4RHBK-PC4RW•4-wire
•Plug-inmountingbracketdesign•Fieldselectablecandela•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•88dBAhorn@16VDC•3volume&temporal/non-temporalsettings•Redorwhite• “P”suffixplainnon-fireprinted
Select-A-Strobe® and Strobe/Horn®
PL-SH1224PL-SL1224PL-SH1224WPPL-SL1224WP•12VDCwith15,35or60cdsetting•24VDCwith15,35,60,75,95or110cdsetting•6candelasettingsperdevice•Candelaselectionviewwindow•Universal,pre-wirebackplate
PL-SL24C
ADA
Chimes & Chime StrobeBK-CHR•Chime-Red
BK-CHW•Chime-White
BK-CHSR•Chime/Strobe-Red
BK-CHSW•Chime/Strobe-White
•2volumesettings•4distincttonesettings•Abletobesynchronized
Wall Horn/StrobesBK-P2R/RPBK-P2RHBK-P2W/WPBK-P2WH/WHP•2-wire
BK-P4RBK-P4RHBK-P4W•4-wire
•Plug-inmountingbracketdesign•Fieldselectablecandela•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•3volume&temporal/non-temporalsettings•88dBAhorn@16VDC•Redorwhite• “P”suffixplainnon-fireprinted
Outdoor Wall Horn/StrobeBK-P2RK/RKPBK-P2RHK/RHKPBK-P2WK/WKPBK-P2WHK/WHKP•2-wire
BK-P4RKBK-P4WK•4-wire
• -40°to151°Ftemperaturerange•Fieldselectablecandela
Outdoor Ceiling Horn/StrobesBK-PC2RKBK-PC2RHKBK-PC2WKBK-PC2WHK•2-wire• -40to151°Ftemperaturerange•Fieldselectablecandela•Outdoorbackboxincluded•Redorwhite
BK-PC4WK•4-wire
Explosion Proof Strobe LightFD-FSEX24PMR•24VDCoperation•Corrosionresistantcastaluminum•NEMA4Xrated•Approvedformarinevisualsignaling•Pendantmountstandard•Additionalmountingoptionsspecialorder• Indoororoutdoormounting•Firelisted
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 103
FireStrobes - Speaker/Strobes
GXS Remote Visual SignalGN-9040780•120VACoperation•Fixed177candelastrobe•Terminalblocks•Wallorceilingmount•Widevarietyofmountingoptions•Faceplateavailableinredorwhite
ADA
Outdoor Ceiling StrobeBK-SCRBK-SCRHKBK-SCWKBK-SCWHK• -40°to151°Ftemperaturerange•Fieldselectablecandela•Outdoorbackboxincluded•Redorwhite
Commander3 Colored Lens DevicesGN-9041327•24VDCoperation•Tamperprooffieldselectablecandelas
15,30,60,75,95&110•SuperSlideTMFeature-testforsupervision•CheckmateTMFeature-instantvoltageverification•FieldSelectableTones:
Temporal3,Continuous,Chime&Whoop•LenscolorsavailableinAmber,Blue,Green&Red
Commander4 Colored Lens DevicesGN-9041375•24VDCOperation•Tamperprooffieldselectablecandelas:
15,30,75,95&115•SuperSlideTM-checkforsupervision•CheckmateTM-InstantVoltageVerification•Fieldselectabletones:
Temporal3orContinuous•LenscolorsavailableinAmber,Blue,Green&Red
Ceiling StrobesBK-SCRBK-SCRHBK-SCW/WPBK-SCWH•Plug-inmountingbracketdesign•Fieldselectablecandela•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•Redorwhite• “P”suffixplainnon-fireprinted
Outdoor Wall StrobesBK-SRK/RKPBK-SRHK/RHKPBK-SWK/WKPBK-SWHK/WHKP• -40°to151°Ftemperaturerange•Fieldselectablecandela•Outdoorbackboxincluded•Redorwhite• “P”suffixplainnon-fireprinted
Wall StrobesBK-SR/RPBK-SRH/RHPBK-SW/WPBK-SWH/WHP•Plug-inmountingbracketdesign•Fieldselectablecandela•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•Redorwhite• “P”suffixplainnon-fireprinted
Colored LensesBK-LENS(X)•Wall
BK-LENS(XX)•Ceiling
•EasytoinstalltoanyindoororoutdoorSpectrAlertAdvancedstrobedevice
•Outdoorratedto-46°Fto151°F•Applicationsincludemassnotification,severeweather
emergencyresponseandmore•UL1638ListedX=(B)bluewall,(R)redwall,(G)greenwall,(A)amberwallXX=(BC)blueceiling,(RC)redceiling,(GC)greenceiling,(AC)amberceiling
Mass Notification Speaker StrobesBK-SPSWALERT•Whiteamberlensspeakerstrobew/“ALERT”
BK-SPSCWCLRALERT•Whiteceilingclearlensspeakerstrobew/“ALERT”
BK-SPSWCLRALERT•Whitewallclearlensspeakerstrobew/“ALERT”
•Plug-indesign•4selectabletapsettings(1/4wattto2watts)• Standardcandelas
Wheelock Semi-Flush Speaker StrobesWH-E50 SeriesWH-E60 Ceiling Series•Fieldselectabletapsfro25or70VRMSoperationfrom
1/8to2watts•Mountto4"squarex2-1/8"deepbackboxwithno
extensionringrequired•FastinstallationwithIN/OUTscrewterminals
WH-110226(red),WH-110227(white)•Wallmount,15/30/75/110cdWH-113747(white),
WH-113748(red)
ET70WP Weatherproof Speaker StrobesWH-119077WH-113179• 24VDCwallmount,75cd
WH-114885WH-114891•24VDCwallmount,selectable135/185cd
WH-114452WH-114454•24VDCceilingmount,Selectable115/177cd
SSPK24WLP Wall Mount Speaker/StrobesGN-9041413•24VDCstrobeoperation•25or70.7VRMS•Fieldselectablepowertaps:
1/8,1/4,1/2,1,2or4Watts•Tamperprooffieldselectablecandelaoptions:
15,30,60,75and110•Fixed15/75candelaunitalsoavailable•Frequencyrange:400-4000Hz•Mountstoa4"x21/8"squaredeepbackbox
ADA
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us104
Fire
Speaker/Strobes - Notification AccessoriesSSPKCLP Ceiling Speaker/StrobeGN-9041441•24VDCstrobeoperation•25or70.7VRMS•Fieldselectablepowertaps:
1/8,1/4,1/2,1,2,or4Watts•Tamperprooffieldselectablecandelaoptions:
15,30,75,95&115•Frequencyrange:400-4000Hz•Mountstoa4"x21/8"squaredeepbackbox
ADA
Wall Mount Speaker StrobesBK-SPSW/WP/WH/WHPBK-SPSR/RP/RH/RHP•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•4selectabletapsettings(1/4wattto2watts)•Stroberatedfor12&24VDC/FWR•Speaker25or70.7VRMSselectable•Plug-indesign•Redorwhite• “P”suffixplainnon-fireprinted
Select-A-SpeakerTM SeriesPL-SSRPL-SSSPL-SS/SR2PL-SS/SR8• Indoororoutdoor•Selectable25VRMSor70VRMS•HighdBoutput•12-18AWGterminals•400Hz-4000Hzfrequencyrange•ULlisted1480•Mustuse4BX-3or4BX-5backbox
WSSPK Outdoor Speaker & Speaker/StrobeGN-9041433GN-9041437•24VDCstrobeoperation•25or70.7VRMs•Fieldselectablepowertaps:1/8,1/4,1/2,1,2or4
watts•Speaker/Strobefixed15/75candelastrobe•Frequencyrange:400-4000Hz•ShippedaskitwithGBLPoutdoorbackbox
ADA
Wall Mount Speaker StrobesBK-SPSWV/WVPBK-SPSRV/RVP•HighdBoutput•Plug-indesign•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•4selectabletapsettings(1/4wattto2watts)•Stroberatedfor12&24VDC/FWR•Speaker25or70.7VRMSselectable•Redorwhite
Outdoor Speaker/StrobesBK-SPSWK/WKPBK-SPSRK/RKPBK-SPSCWK/WHK• -40°to151°Ftemperaturerange•NEMA4Xrated•Plasticweatherproofbackboxincluded•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•Redorwhite• “P”suffixplainnon-fireprinted
Ceiling Mount Speaker/StrobesBK-SPSCW/WP/WH/WHPBK-SPSCR/RH•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•4selectabletapsettings(1/4wattto2watts)•Stroberatedfor12&24VDC/FWR•Speaker25or70.7VRMSselectable•Plug-indesign• “P”suffixplainnon-fireprinted
Ceiling Mount Speaker/StrobesBK-SPSCWV/WVP/WVH/WVHPBK-SPSCRV/RVH•HighdBoutput•Plug-indesign•Standardcandelas:15,15/75,30,75,95,110,115• “H”suffixcandelas:135,150,177,185•4selectabletapsettings(1/4wattto2watts)•Stroberatedfor12&24VDC/FWR•Speaker25or70.7VRMS
selectable•Redorwhite
Mass Notification StrobesBK-SWALERT•Whiteamberlensstrobewith“ALERT”
BK-SCWCLRALERT•Whiteceilingclearlensstrobewith“ALERT”
BK-SWCLRALER•Whiteclearlensstrobewith“ALERT”
•Plug-indesign• Fieldselectablecandela
Back Box SkirtBK-BBS2BK-BBSW2BK-BBSC2BK-BBSCW2•Forsurfacemountapplications•Redandwhite•Wallorceiling•Compatiblewith4"x4",4"octagonand2"x4"
backboxes
Sync-CircuitTM ModuleBK-MDL3BK-MDLW3•WorkswithSpectrAlertAdvancehorns,strobes,
horn/strobes,chimes,chime/strobes,andminihorns•2wirestohorns,strobes&horn/strobecombo•Hornssynctotemp3•3yearwarranty
120VAC Adaptor Mounting PlateBK-MP120K•Operatesat120VAC• Indoor/outdooruse•Compatiblewithall2-wireSpectrAlertAdvancedevices•Plug-indesign
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 105
FireNotification Accessories - Power Supplies & Surge Protection
NAC Power ExtenderAX-AL842ULAD•24VDC@8amp
AX-AL1042ADA•24VDC@10amp
•GeneratesWheelock®,SystemSensor®,Gentex®,FaradayandAmsecosyncprotocols
• Four(4)ClassAorfour(4)ClassBIndicatingCircuits•Two(2)Aux.PowerOutputs•ULlisted8649thEd.
End of Line RelayUS-R64•ULlistedandCAStateFireMarshalApproved•Adaptabletoanystandard4or6wiresystem•Provides12-24VDCE.O.L.PowerSupervision•ULlistedandCAStateFireMarshallApproved•Size2-3/8"x2-1/4"x1"
Speaker/Strobe Back Box SkirtsBK-SPBBSWBK-SPBBS•Wall
BK-SPBBSCWBK-SPBBSC•Ceiling
•ForSpectrAlertAdvancespeakerandspeakerstrobes•Forsurfacemountapplications•Availableinredorwhite
Speaker/Strobe AccessoriesBK-RFPW•RetrofitPlate•9.5"x7.5"forretrofitapplications•FitsfootrprintoflegacySpectrAlertspeakerstrobes
BK-TRW•TrimRing• Optionalaccessorytoprovideadditionalspaceinbackbox
BK-TRCW•Ceiling
•Redorwhite
Remote Power Supply/SyncFL-FCPS24FS6FL-FCPS24FS8•ULListedfor2operatingmodes:•4/6ampsinstandalone&6/8ampsinexpandermode• Integralbatterychargerupto18Ah•Built-inNACsyncforSystemSensor,Wheelockand
Gentexstrobes
Fire Control Panel Power ProtectorDK-120S20A•120VACpowerprotection•39,000Ampsurgecapacity,20Amaximumcurrent• FourstagehybriddesignwithEMI/RFInoisefiltering•Seriesconnection
DK-120S15A•15Amaximumcurrent
DK-DTK2LVLPF•Firealarmpanelsurgeprotection•Specificallydesignedtoprotect24VSLCloops
Power Supply & Expansion ModWH-PS6WH-PS8•4ClassB,2ClassAcircuits•UL864,9thEdition•DistinguishableGroundFault(GF)DiagnosticLED’s• IntegratedSynchronizationBus•TrueInputFollowermode•WH-PS8withLargerChassisforcontrolmodules
WH-PSEXP•WH-PSEXPExpansionBoardtoexpandto
8ClassBor4ClassAcircuits
NAC Power ExtenderAX-AL802ULAD•24VDC@8amp
AX-AL1002ADA•24VDC@10amp•GeneratesWheelock®,SystemSensor®,Gentex®,
FaradayandAmsecosyncprotocols•Two(2)ClassAorfour(4)ClassBIndicatingCircuits.•One(1)Aux.PowerOutput@1ampsupplycurrent
withBatteryBackUp•UL8649thEd.
Addressable Monitor ModuleFL-MMF300•ClassAorBIDC(Drycontactinputdevices)•Providesinterfacetocontactdevices,waterflow
switchesorpullstations
Power SupplyPL-PSN Series•PL-PSN64has6Ampswith4Outputs•PL-PSN106has10ampswith6Outputs•TroubleMemoryfeaturecapturestroubleswhichhave
previouslyrestored•SupervisedBatteryCharger:27.3@1A
(supports7-55AHbatteries)•PassThrumodeallowstheOutputstomatchtheInput
Signal•Quadrasynctechnologyallowssynchronized
notificationappliancecircuitsformultiplebrands:Potter/AMSECO®,Wheelock®,Gentex®,SystemSensor®
6-Amp Distributed Power ModuleSK-5495•6ampsofnotificationpower•Advancedswitchmodedesignreducesdamagingheat
andmanagespowerupto50%moreefficientlythanothersystems
•Dipswitchesallowforeasyconfiguration•24VDCfilteredoutputvoltages
9-Amp Distributed Power ModuleSK-5499•9ampsofnotificationpower•Advancedswitchmodedesignreducesdamagingheat
andmanagespowerupto50%moreefficientlythanothersystems
•Dipswitchesallowforeasyconfiguration•24VDCfilteredoutputvoltages
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us106
Fire
Additional Fire SolutionsDH Series Electromagnetic Door HoldersES-DHF24120C •Chromesemi-flushmount
ES-DHS24120C •Chromesurfacemount
ES-DHR24120C •Chromerecessedmount
•360°swivelmountreducesinstallationtime•Flexibleavailablemountinghardware•Low15mA@24VAC/DC-35lb.holdingforce•Availableindesignerchrome&brassplatedfinishessubstitute“B”for“C”inpartnumberforbrassfinish
ES-ER1C •Chrome1"extensionrod
ES-ER3C •Chrome3"extensionrod
ES-BPC •Chromebackplate
DH Series Floor MountElectromagnetic Door HoldersES-DHFM12412 •Singlecoil,24/120V
ES-DHFM22412 •Dualcoil,24/120V
ES-DHFM11224 •Singlecoil,12/24V
ES-DHFM21224 •Dualcoil,12/24V
SEM1960 Wall Magnet (Surface Mount)4N-SEM1960•Tri-Voltage-12VDC,24VAC/DC,or120VACinputs•35lb.holdingforce•HighImpactplastichousing•EasyPeelN’Stickinstallationtemplate•ULListedforsmokebarrierandlabeledfiredoors• Installationplacementchartformountingaccuracy
Latching AnnunciatorDA-LA Series •Supportsmultipleunitsinparallel•Monitorsdoorcontacts•Easyinstallation•Scalableconfiguration•HighintensityLEDs=highvisibility•Acceptszonebypassswitches•Provideszoneoutputs•Flexible,tamper-proofzonelabeling•Alarmindicationonpowerfailure
Tabular AnnunciatorDA-TA Series •10-25%lowercostthancustomannunciators•Easytoinstallandmodify•Shipscompletelyassembled• Interoperateswithstandardcontrolpanels•HighintensityLEDs=highvisibility• Interior/exterior,surfaceorflushmount•ULListed
Intelligibility Meter for Fire Evacuation Systems GO-DSP2B •ComplieswithCodeNFPA,Section4-3.1.5(IEC)
Standard60268-16•MeasuresSTIandCISplusSoundPressureLevel•ComputerInterfacetomakereportsormodifyfornoise•Quickandrepeatableresults
GO-DSP2BKIT • IncludesTAALKBOXtoinsertSTI-PACDintobuilding
controlrooms
SEM7830 Wall Magnet (Surface Mount)4N-SEM7830•Tri-Voltage-12VDC,24VAC/DC,or120VACinputs•35lb.holdingforce•Heavydutydiecastarmatureandhousing•EasyPeelN’Stickinstallationtemplate•ULListedforsmokebarrierandlabeledfiredoors• Installationplacementchartformountingaccuracy
AVS Synchronization ModuleGN-9041243•Synchronizehorn&strobewithonly2wires•Moduleisratedfor3Ampscontinuouscurrent
&5Ampssurgeorin-rushcurrent•Optiontosilencehornwhilestrobescontinuetoflash•Operates1ClassAcircuitor2ClassBcircuits
Temperature Controlled EnclosuresBW-BW124ACHT•24"Wx24"Hx12"D,2000BTUAC,500WattHeater
BW-BW136ACHT•24"Wx36"Hx12"D,2000BTUAC,500WattHeater
BW-BW1248ACHT•24"Wx24"Hx8"D,800BTUAC,150WattHeater
•ULlistedAC,heater,airfilter,andthermostat•AsshownwithACandheat,butalsoavailablewithAC
only,heatonly,asfan-cooledunitsorasenclosureonly•Add“W”totheendofthesepart#stoaddawindow
MR-100/200 Series Relays06-MR101CR•24VDC,24/120/230VAC,10A,SPDT
06-MR201CR•24VDC,24/120/230VAC,10A,DPDT
•Codecompliantforfire&lifesafetyuse• Idealforgeneralpurposeapplications•Polarized•Redenclosure•Completelineavailable
MR-300 Low Voltage, Low Current, TTL + RelaysO6-MR311CR•1position,SPDT,redenclosure
O6-MR321CR•1position,DPDT,redenclosure
•12-27VDChost/5-27VDCtrip(smA-17mA)•Contacts10A@120VAC/7A@24VDC/AC•Superlowcurrent&TTLleveltripformultipurpose
applications•Polarized
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us 107
FireAdditional Fire Solutions
SENTRY Pull Station Protective CoverAN-STFRC01•Rugged,poly-carbonatecoverprotectsmanualpullstationsfrom:
* Accidentalormaliciousfalsealarms* Vandalism* Weather* Otherharmfulelements
•Bottomhingedesignallowsforeasyaccesstoactivatepullstationsinanemergencywithoutobstruction
•Protrudeslessthan4"perADArequirementsandfeaturesraisedletteringandBrailleinstructionsoncover
•Onlycoverwithtrueonehandoperationcapability•Varietyofconfigurationsavailabletosatisfymostapplicationrequirements•Accessoriesinclude:
*AlarmModule-AN-STALM01*ExtenderKit-AN-STXTR01*BackPlateKit(roughsurfacemounting)-AN-STBKP01*NEMA3RWeatherProofKit-AN-STWPK01
•MeetsADA;28CPRPart36
ADA
Top
Bottom
PAM Series RelaysO6-PAM1•24VDC,24/120VAC,10A,SPDT
O6-PAM2•12/24VDC,7A,SPDT
O6-PAM4•9-40VDC,10A,SPDT
O6-PAMSD•18-32VDC,7A,SPDT•Codecompliantforfire&lifesafetyuse•Polarized
RIC1, RIC2 Multi-Voltage Relay ModulesO6-SSURIC1•24VAC/24VDC/115VAC,10A,SPDT
O6-SSURIC2•24VAC/24VDC/115VAC,10A,DPDT•RedLEDilluminateswhencoilisenergized•Mountsina1/2"knockout•12"wireleads•Sturdyfullplasticenclosure•SuitableforusewithHVAC,temperaturecontrol,
firealarms,security,energymanagement,andlightingcontrolsystems
Universal® StopperSF-13020FR•Flushmountedprotectivecoverwithhorn,firelabel• Lowprofile–lessthan4inches•Accommodatesdualactionpullstations•ADACompliant,NEMA3RPending
SF-13220FR•SameasSF-13020FR,Surfacemount
SF-13420FR•Enclosedbackbox,sealedmountingplate,withhorn,firelabel•NEMA3RandNEMA4XPending
•Manyothermodelsavailable
ADA
Stopper® II Protective CoverSF-1100•Protectivepolycarbonatecoverhelpspreventfalsefirealarmswithoutrestrictinglegitimatealarms•Alarmlocatedincoverisactivatedwhenunitisopenedafractionofaninch,drawingattentioninahurry!• Lifetimeguaranteeagainstbreakageofpolycarbonatehousing,oneyearguaranteeonelectronics
(modelswithhorn,etc.)•Hornhastwoselectablewithaswitchvolumeoptions:95dBor105dB•9-voltbatteryoperatedalarm,locatedincover(batteryincluded)•Designedforuseoverflushmountedpullstations•CoverisUV-stabilized•UL/cULListedforusewithstandardfirelabelingandcustomlabelingwhenprotectingnon-fireunits•Polycarbonatetestedto-40°Fto120°F(-40°Cto49°C)• Idealforpublicbuildings,schools,universities,hospitals,nursinghomes,daycares,governmentoffices,etc.•Availableinred,blue,greenoryellow(redshown)•Modelsavailable:
SF-1100:Coverwithhornforflushmountapplications(shown)SF-1130:Coverwithhornforsurfacemountapplications(shown)SF-1200:CoverwithnohornforflushmountapplicationsSF-1230:Coverwithnohornforsurfacemountapplications
•Weathermodels:SF-1150:CoverwithhornandgasketsforflushmountapplicationsSF-1155:CoverwithhornandgasketsforsurfacemountapplicationsSF-1200AHTR:NEMA3RheatedcoverSF-1250:CoverwithnohornandgasketsforflushmountapplicationsSF-3150:Coverwithnohornandgasketsforsurfacemountapplications
For Orders, Call: 1-800-233-6261 | For Systems Sales And Support, Call 1-800-234-7971 | www.adiglobal.com/us108
Fire
Additional Fire SolutionsHeated Polycarbonate EnclosureSF-7510AHTR•Encloseddeepbackbox,keylock
SF-7510FHTR•Enclosedbackbox,keylock
SF-7511AHTR•Encloseddeepbackbox,thumblock
SF-7511FHTR•Enclosedbackbox,thumblock
• Heatedcoverhelpsprotectdevicesfromsevereenvironments•Offers3thermostats(control,overtemp,lowtemp)•RadiantheatplatepreventsLCDdisplaysfromfreezing
NEMA 4X Polycarbonate CabinetSF-7520•Helpsguardagainstvandalism,dirt,dustandgrime• Includeskeylock(modelSF-7521forthumblock)•Cleardesignallowsvisibilityatalmostanyangle• Steelinternalmountingplateprovided•Additionalopeningwheresecondarypadlockorsafety
sealcanbeused• Lifetimeguaranteeagainstbreakageofpolycarbonatecover•Availablewithalarm•Alsoavailablewithheater(SF-7520HTR)
Polycarbonate EnclosuresSF-7550•19.75"x24.8"x7.3",ULListed,NEMA4X
SF-STI7530•12"x14"x6.44"•Multipurposecabinetforlargeelectronicdevices• Includeskeylock•Designallowsvisibilityfromalmostanyangle• 2rotaryactionlatchesw/additionaleyeletsforsecondarylock•Lifetimeguaranteeagainstbreakageinnormaluse
SF-7551•Modelwiththumblock,ULListed,NEMA4X
Steel Web Stopper® Protective CoverSF-9601•Helpsprotectsmokedetectorsfromvandalism
andaccidentaldamage•Web-likeoctagonshapeof9-gaugecoatedsteelwire
makesthemextremelydifficulttobreak•Lifetimeguaranteeagainstbreakageinnormaluse•Simpleremovalforservicingdetector•Stainlesssteelversionsalsoavailable•3modelsavailableforflushmount:
SF-9601,SF-9604,SF-9609•3modelsavailableforsurfacemount:
SF-9602,SF-9605,SF-9610
Series Loop Test/Maintenance ModuleBK-2WMOD2•Fori3Seriesdetectors•Enablesremotemaintenancesignalon2-wiredetectors
toworkon4-wireoutputs•ProvidesStyleDinitiatingcircuit• EnablesEZwalktest
Beam Smoke Detector AccessoriesBK-BEAMMMK• Multi-mountkitforBK-BEAM1224(S),allowsthedetector
tomountonwall,ceilingandvariousanglesBK-BEAMSMK•AllowsforsurfacemountingoftheBK-BEAM1224(S),
mustbeusedwhenBK-BEAMMMKisusedBK-BEAMLRK•LongrangekitforBK-BEAM1224(S),
increasesbeamdetectorrangeupto328'
Multi-Voltage RelaysBK-PR1BK-PR2BK-PR3•EpoxyencapsulatedSPDTrelayswithanactivationLED
BK-EOLR1•EndoflineepoxyencapsulatedSPDTrelay
•Highcurrentswitchingapplications,suchasfan&damperassemblycontrol,doorcontrol,airhandlingunitcontrolsandmore
•Easy&flexibleinstallation•Reliable&robustdesign
Multi-Voltage RelaysBK-R10T/R20T•Singletrackmountrelays,SPDT/DPDT
BK-R14T/R24T•4-gangtrackmountrelays,SPDT/DPDT
BK-R10E/R20E•Singlesteelenclosurerelays,SPDT/DPDT
BK-R14E/R24E•4-gangsteelenclosurerelays,SPDT/DPDT
Piezo AnnunciatorBK-APA151•ProvidesgreenpowerLEDandredalarmLED•Audibleannunciatorofanalarmsignal• Intendedforusein4-wireconventionalductsmoke
detectorapplicationswithoutasystemcontrolpanel,tocomplywithNFPA90A
Remote Test Station with KeyBK-RTS151KEY•Keyactivatedtest&resetfunctions•Multi-coloredLEDindicatespower(green)andalarm
(red)• Installsintoasingle-gangelectricalbox
Multi-Signaling AccessoryBK-RTS2•Multi-functionaccessory•ProvidesLEDdetectorstatus•Audible&visiblenotification•Remotetestcapable,sensitivitytestcapable•CompatibletoInnovairFlex4-wireductdetectorsonly•AOS(AddonStrobe)option
Envi-ro-tech DusterT8-167115S•Cleanawaydustandcontaminants•Clearsmokealarmtesters•100%non-flammable•15oz.aerosol•Bestvalue