207E5100.fm/2 Schneider Electric
Catalogue numbers NT06 to NT16fixed circuit breakersCircuit breaker selection
A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to:
b the basic circuit breaker
b a control unit
b a top connection
b a bottom connectionA communication option and various auxiliaries and accessories may also be added.
.
(1) select a 4P basic circuit breaker with neutral on the right page 18.All other catalogue numbers are unchanged.
Auxiliaries and accessories:
b for fixed devices: see page 4
b for fixed or drawout devices: see page 11Switch-disconnector version: see page 14Source changeover assembly: see page 11
E46
423
Basic circuit breakerType H1
3P 4PIn (A at 40°C) Icu (kA for U = 220/415 V) - Ics = 100% Icu
NT06 630 42 47110 47115NT08 800 42 47120 47125NT10 1000 42 47130 47135NT12 1250 42 47140 47145NT16 1600 42 47150 47155Type L1
3P 4PIn (A at 40°C) Icu (kA for U = 220/415 V) - Ics = 100% Icu
NT06 630 150 47112 47117NT08 800 150 47122 47127NT10 1000 150 47132 47137Option
Neutral on the right (1)
Micrologic control unit"ammeter" A
3P/4PMicrologic 2.0 A basic protection 47282Micrologic 5.0 A selective protection 47285Micrologic 6.0 A selective + earth-fault protection 47286Micrologic 7.0 A selective + earth-leakage protection 47287"power meter" P
3P/4PMicrologic 5.0 P selective protection 47289Micrologic 6.0 P selective + earth-fault protection 47290Micrologic 7.0 P selective + earth-leakage protection 47291"harmonic meter" H
3P/4PMicrologic 5.0 H selective protection 47293Micrologic 6.0 H selective + earth-fault protection 47294Micrologic 7.0 H selective + earth-leakage protection 47295
Communication optionModbus COM 47405Modbus COM eco 47406Digipact COM 47409
207E5100.fm/3Schneider Electric
Catalogue numbers NT06 to NT16 fixed circuit breakers (cont.)Circuit breaker selection (cont.)
Front connection
E47
757
3P 4P630/1600 A Top 47328 47330
Bottom 47329 47331
Front connection accessoriesBare-cable connectors + 1 connector shield for 4 x 240 mm2 cables
E46
887
3P (3 parts) 473334P (4 parts) 47334
Vertical connection adapters 630/1600 A
E46
426
3P (3 parts) 336424P (4 parts) 33643
Cable lug adapters 630/1600 A
E46
427
3P (3 parts) 336444P (4 parts) 33645
Interphase barriers
E79
151
3P/4P top (3 parts) 336483P/4P bottom (3 parts) 33648
Arc chute screen
E74
437
3P 473354P 47336
Rear connectionVertical connection
E46
429
3P 4P630/1600 A Top 33604 33614
Bottom 33605 33615Horizontal connection
E46
430
3P 4P630/1600 A Top 33606 33616
Bottom 33607 33617Rear connection accessories
E79
151
Interphase barriers3P/4P top (3 parts) 336483P/4P bottom (3 parts) 33648
Common accessories for front and rear connectionsSpreaders
E46
431
630/1600 A 3P 336224P 33623
For front and horizontal rear connection
Cable lug kits
E47
820
240 mm2 3P (6 lug kit) 330134P (8 lug kit) 33014
300 mm2 3P (6 lug kit) 330154P (8 lug kit) 33016
207E5100.fm/4 Schneider Electric
Catalogue numbers NT06 to NT16fixed circuit breakers (cont.)Indication contacts
ON/OFF indication contacts (OF)
E46
463
Changeover contacts (6 A - 240 V) 4 (standard)1 low-level OF to replace 1 standard OF (4 max.) 47339
"Fault trip" indication contacts (SDE)
E47
758
Changeover contact (5 A - 240 V) 1 (standard)1 additional SDE (5 A - 240 V) 473401 additional low-level SDE 47341
Programmable contacts (*) (programmed via Micrologic control unit)
E46
434
2 contacts (M2C) (5 A - 240 V) 474036 changeover contacts (M6C) (5 A - 240 V) 47404(*) for Micrologic control units P and H only.
M2C
E46
435
M6C
207E5100.fm/5Schneider Electric
Catalogue numbers NT06 to NT16fixed circuit breakers (cont.)Remote operation
Remote ON/OFFGear motor
E46
436
MCHAC 50/60 Hz 48 V 47391
100-130 V 47395200-240 V 47396277-415 V 47398440-480 V 47400
DC 24-30 V 4739048-60 V 47391100-130 V 47392200-250 V 47393
Instantaneous voltage releases
E46
437
Closing release Opening releaseStandard XF MXAC 50/60 Hz 12 V DC 47349 47359DC 24-30 V DC, 24 V AC 47350 47360
48-60 V DC, 48 V AC 47351 47361100-130 V 47352 47362200-250 V 47353 47363277 V AC 47354 47364380-480 V AC 47355 47365
Communicating XF com MX comAC 50/60 Hz 12 V DC 47310 47320DC 24-30 V DC, 24 V AC 47311 47321
48-60 V DC, 48 V AC 47312 47322100-130 V 47313 47323200-250 V 47314 47324277 V AC 47315 47325380-480 V AC 47316 47326
"Ready to close" contact (1 max.)
E46
438
PF1 changeover contact (5 A - 240 V) 473421 low-level changeover contact 47343
Electrical closing pushbutton
E46
439
BPFE1 pushbutton 47512
Remote reset after fault trip
E46
660
Electrical reset Res110-130 V AC 47344220-240 V AC 47345Automatic reset RARAdaptation 47346 (*)
Remote trippingInstantaneous voltage release
E46
437
2nd MX or MNAC 50/60 Hz 12 V DC 47369DC 24-30 V DC, 24 V AC 47370 47380
48-60 V DC, 48 V AC 47371 47381100-130 V 47372 47382200-250 V 47373 47383277 V AC 47374380-480 V AC 47375 47385
MN delay unit
E46
694
R (non-adjustable) Rr (adjustable)AC 50/60 Hz 48-60 V 33680DC 100-130 V 33684 33681
200-250 V 33685 33682380-480 V 33683
(*) no charge.
207E5100.fm/6 Schneider Electric
Catalogue numbers NT06 to NT16drawout circuit breakersCircuit breaker selection
A Masterpact drawout circuit breaker is described by 5 catalogue numbers corresponding to:b the basic circuit breakerb a control unitb a chassisb a top connectionb a bottom connectionA communication option and various auxiliaries and accessories may also be added.
.
(1) select a 4P basic circuit breaker with neutral on the right page 18.All other catalogue numbers are unchanged.
Auxiliaries and accessories:b for drawout devices: see page 8b for fixed or drawout devices: see page 11Switch-disconnector version: see page 14Source changeover assembly: see page 11
E46
441
Basic circuit breakerType H1
3P 4PIn (A at 40°C) Icu (kA for U = 220/415 V) - Ics = 100% Icu
NT06 630 42 47200 47205NT08 800 42 47210 47215NT10 1000 42 47220 47225NT12 1250 42 47230 47235NT16 1600 42 47240 47245Type L1
3P 4PIn (A at 40°C) Icu (kA for U = 220/415 V) - Ics = 100% Icu
NT06 630 150 47202 47207NT08 800 150 47212 47217NT10 1000 150 47222 47227Option
Neutral on the right (1)
Micrologic control unit"ammeter" A
3P/4PMicrologic 2.0 A basic protection 33525Micrologic 5.0 A selective protection 33532Micrologic 6.0 A selective + earth-fault protection 33533Micrologic 7.0 A selective + earth-leakage protection 33534"power meter" P
3P/4PMicrologic 5.0 P selective protection 47297Micrologic 6.0 P selective + earth-fault protection 47298Micrologic 7.0 P selective + earth-leakage protection 47299"harmonic meter" H
3P/4PMicrologic 5.0 H selective protection 47301Micrologic 6.0 H selective + earth-fault protection 47302Micrologic 7.0 H selective + earth-leakage protection 47303
ChassisFor type H1
3P 4P630/1250 A 33722 337251600 A 33723 33726For type L1
3P 4P630/1000 A 33723 33726
Communication optionChassis + Circuit breaker
Modbus COM 33852 47485Modbus eco COM 33843Digipact COM 33855 47489
207E5100.fm/7Schneider Electric
Catalogue numbers NT06 to NT16drawout circuit breakers (cont.)Circuit breaker selection (cont.)
Chassis front connection
E46
440
3P 4P630/1600 A Top 33727 33733
Bottom 33728 33734
Front connection accessoriesVertical connection adapters 630/1600 A
E46
426
3P (3 parts) 336424P (4 parts) 33643
Cable lug adapters 630/1600 A
E46
427
3P (3 parts) 336444P (4 parts) 33645
Chassis rear connectionVertical connection
E46
429
3P 4P630/1600 A Top 33729 33735
Bottom 33730 33736Horizontal connection
E46
430
3P 4P630/1600 A Top 33731 33737
Bottom 33732 33738Rear connection accessories
E46
428
Interphase barriers3P/4P (3 parts) 33768
Common accessories for front and rear connectionSpreaders
E46
431
630/1600 A 3P 336224P 33623
For front and horizontal rear connection.
Cable lug kits
E47
820
240 mm2 3P (6 lug kit) 330134P (8 lug kit) 33014
300 mm2 3P (6 lug kit) 330154P (8 lug kit) 33016
207E5100.fm/8 Schneider Electric
Catalogue numbers NT06 to NT16drawout circuit breakers (cont.)Chassis locking and accessories
Chassis locking"Disconnected" position locking
E46
685
By padlocksStandard
By keylocksProfalux 1 lock 33773
1 lock + 1 lock with same key profile 337742 locks (different key profiles) 33775
Ronis 1 lock 337761 lock + 1 lock with same key profile 337772 locks (different key profiles) 33778
Optional disconnected/test/connected position locking 33779 (*)Locking kit without locks for
Profalux 33769Ronis 33770Castell 33771Kirk 33772
Door interlock (1 part)
E46
464
Right-hand side of chassis (VPECD) 33786Left-hand side of chassis (VPECG) 33787
Racking interlock
E46
465
Racking interlock (VPOC) 33788
Breaker mismatch protection
E47
765
Breaker mismatch protection (VDC) 33767
Chassis accessoriesArc chute cover
E46
700
3P/4P Standard
Auxiliary terminal shield (CB)
E46
698
Terminal shield 3P 337634P 33764
Safety shutters
E46
699
Safety shutters (VO) 3P 337654P 33766
(*) no charge.
207E5100.fm/9Schneider Electric
Catalogue numbers NT06 to NT16drawout circuit breakers (cont.)Indication contacts
ON/OFF indication contacts (OF)
E46
467
Changeover contacts (6 A - 240 V) 4 (standard)
1 low-level OF to replace 1 standard OF (4 max.) 33806
"Fault trip" indication contacts (SDE)
E47
759
Changeover contact (5 A - 240 V) 1 (standard)
1 additional SDE (5 A - 240 V) 47430
1 additional low-level SDE 47431
Programmable contacts (*) (programmed via Micrologic control unit)
E46
686
2 contacts M2C (5 A - 240 V) 47483
6 changeover contacts M6C (5 A - 240 V) 47484(*) for Micrologic control units P and H only.
M2C
E46
687
M6CCarriage switches (connected / disconnected / test position)
E46
661
Changeover contacts (6A - 240 V)1 connected position contact (3 max.) 337511 test position contact (1 max.) 337521 disconnected position contact (2 max.) 33753And/or low-level changeover contacts
1 connected position contact (3 max.) 337541 test position contact (1 max.) 337551 disconnected position contact (2 max.) 33756
Auxiliary terminals for chassis alone3 wire terminal (30 parts) 470716 wire terminal (10 parts) 47072Jumpers (10 parts) 47900
207E5100.fm/10 Schneider Electric
Catalogue numbers NT06 to NT16drawout circuit breakers (cont.)Remote operation
Remote ON/OFFGear motor
E46
662
MCHAC 50/60 Hz 48 V 47461
100-130 V 47465200-240 V 47466277-415 V 47468440-480 V 47470
DC 24-30 V 4746048-60 V 47461100-130 V 47462200-250 V 47463
Instantaneous voltage releaseClosing release Opening release
Standard XF MXAC 50/60 Hz 12 V DC 47439 33809DC 24-30 V DC, 24 V AC 47440 33810
48-60 V DC, 48 V AC 47441 33811100-130 V 47442 33812200-250 V 47443 33813277 V AC 47444 33814380-480 V AC 47445 33815
Communicating XF com MX comAC 50/60 Hz 12 V DC 47411 33791DC 24-30 V DC, 24 V AC 47412 33792
48-60 V DC, 48 V AC 47413 33793100-130 V 47414 33794200-250 V 47415 33795277 V AC 47416 33796380-480 V AC 47417 33797
"Ready to close" contact (1 max.)
E46
664
PF1 changeover contact (5 A - 240 V) 474321 low-level changeover contact 47433
Electrical closing pushbutton
E46
439
BPFE1 pushbutton 47512
Remote reset after fault trip
E46
660
Electrical reset Res110-130 V AC 47434220-240 V AC 47435Automatic reset RARAdaptation 47346 (*)
Remote trippingInstantaneous voltage release
E46
663
2nd MX or MNAC 50/60 Hz 12 V DC 47449DC 24-30 V DC, 24 V AC 47450 33819
48-60 V DC, 48 V AC 47451 33820100-130 V 47452 33821200-250 V 47453 33822277 V AC 47454380-480 V AC 47455 33824
MN delay unit
E46
694
R (non-adjustable) Rr (adjustable)AC 50/60 Hz 48-60 V 33680DC 100-130 V 33684 33681
200-250 V 33685 33682380-480 V 33683
(*) no charge.
207E5100.fm/11Schneider Electric
Catalogue numbers Accessories for NT06 to NT16 fixed or drawout circuit breakers
Circuit breaker lockingPushbutton locking device
E46
666
By padlocks 33897
OFF position locking
E46
666
By padlocks + BPFE support47514
By keylocks + BPFE supportProfalux 1 lock 47519
1 lock + 1 lock with same key profile 47520Ronis 1 lock 47521
1 lock + 1 lock with same key profile 47522Locking kit without locks for
Profalux 47515Ronis 47516Kirk 47517Castell 47518
Other circuit breaker accessoriesMechanical operation counter
E46
667
operation counter CDM 33895
Escutcheon and accessories
E46
668
Fixed DrawoutEscutcheon 33718 33857Transparent cover (IP 54) 33859Escutcheon blanking plate 33858
Escutcheon Cover Blanking plate
Mechanical interlocking for source changeoverInterlocking using connecting rods
E47
760
Complete assembly with 2 adaptation fixtures + rods2 Masterpact NT fixed devices 339122 Masterpact NT drawout devices 33913
Interlocking using cables (*)Choose 2 adaptation fixtures (1 for each breaker) + 1 set of cables1 adaptation fixture for Masterpact NT fixed devices 332001 adaptation fixture for Masterpact NT drawout devices 332011 set of 2 cables 33209(*) Can be used with any combination of NT or NW, fixed or drawout devices.
Cable-type door interlock
E70
742
1 complete assembly for Masterpact NT fixed devices 339201 complete assembly for Masterpact NT drawout devices 33921
E46
669
E46
670
207E5100.fm/12 Schneider Electric
Catalogue numbers Accessories for NT06 to NT16 fixed or drawout circuit breakers(cont.)
Accessories for Micrologic control unitsExternal sensorsExternal sensor for earth-leakage protection (TCE)
E46
671
Sensor rating 400/1600 A (for Micrologic P and H with 3P devices) 33576
Rectangular sensor for earth-leakage protection
E46
672
280 mm x 115 mm 33577
Source ground return (SGR) earth fault protection
E46
671
External sensor (SGR) 33579
MDGF summing module 48891
Voltage measurement input (for breakers supplied via bottom terminals)
E46
674
Voltage measurement input Fixed 47506
Drawout 47507
Long-time rating plug (limits setting range for higher accuracy)
E46
674
Standard 0.4 to 1 x Ir 33542
Low-setting option 0.4 to 0.8 x Ir 33543
High-setting option 0.8 to 1 x Ir 33544
Without long-time protection off 33545
Zone Selective Interlocking option for Micrologic P and HZSI Standard
External power supply module
E47
787
24-30 V DC 5444048-60 V DC 54441125 V DC 54442110 V AC 54443220 V AC 54444380 V AC 54445
Battery module1 24 V battery 54446
Test equipmentMini test kit
E59
921
33594
Portable test kit
E59
554
33595
Special settingsFor circuit breaker deratingCatalogue number to be added to those describing the circuit breaker rating
Rating NT08 NT10 NT12 NT16400 47053 47053630 33091 33091 33091800 33092 33092 330921000 33093 330931250 33094Note: for ratings In = 100 or 250 A, please contact us.
L3
G1
AD 220A
L4
G2
Input
24VDC
Output
24VDC
207E5100.fm/13Schneider Electric
207E5100.fm/14 Schneider Electric
Catalogue numbers NT06 to NT16fixed switch-disconnectorsSwitch-disconnector selection
A Masterpact fixed switch-disconnector is described by 3 catalogue numbers corresponding to:b the basic switch-disconnectorb a top connectionb a bottom connectionA communication option and various auxiliaries and accessories may also be added.
.
Auxiliaries and accessories:b for fixed devices: see page 4b for fixed or drawout devices: see page 11Source changeover assembly: see page 11
E46
675
Basic switch-disconnectorType HA
3P 4PIn (A at 40°C) Icm (kA peak for U = 220/690 V)
NT06 630 60 47159 47160NT08 800 60 47161 47162NT10 1000 60 47163 47164NT12 1250 60 47165 47166NT16 1600 60 47167 47168
Communication optionModbus COM 47405Digipact COM 47409
207E5100.fm/15Schneider Electric
Catalogue numbers NT06 to NT16fixed switch-disconnectors (cont.)Switch-disconnector selection (cont.)
Front connection
E47
757
3P 4P630/1600 A Top 47328 47330
Bottom 47329 47331
Front connection accessoriesBare-cable connectors + 1 connector shield for 4 x 240 mm2 cables
E46
887
3P (3 parts) 473334P (4 parts) 47334
Vertical connection adapters 630/1600 A
E46
426
3P (3 parts) 336424P (4 parts) 33643
Cable lug adapters 630/1600 A
E46
427
3P (3 parts) 336444P (4 parts) 33645
Interphase barriers
E79
151
3P/4P top (3 parts) 336483P/4P bottom (3 parts) 33648
Rear connectionVertical connection
E46
429
3P 4P630/1600 A Top 33604 33614
Bottom 33605 33615Horizontal connection
E46
430
3P 4P630/1600 A Top 33606 33616
Bottom 33607 33617Rear connection accessories
E79
151
Interphase barriers3P/4P top (3 parts) 336483P/4P bottom (3 parts) 33648
Common accessories for front and rear connectionSpreaders
E46
431
630/1600 A 3P 336224P 33623
For front and horizontal rear connection
Cable lug kits
E47
820
240 mm2 3P (6 lug kit) 330134P (8 lug kit) 33014
300 mm2 3P (6 lug kit) 330154P (8 lug kit) 33016
207E5100.fm/16 Schneider Electric
Catalogue numbers NT06 to NT16drawout switch-disconnectorsSwitch-disconnector selection
A Masterpact drawout switch-disconnector is described by 4 catalogue numbers corresponding to:b the basic switch-disconnectorb a chassisb a top connectionb a bottom connectionA communication option and various auxiliaries and accessories may also be added.
.
Auxiliaries and accessories:b for drawout devices: see page 8b for fixed or drawout devices: see page 11Source changeover assembly: see page 11
E00
000
Basic switch-disconnectorType HA
3P 4PIn (A at 40°C) Icm (kA peak for U = 220/690 V)
NT06 630 60 47248 47249NT08 800 60 47250 47251NT10 1000 60 47252 47253NT12 1250 60 47254 47255NT16 1600 60 47256 47257
Chassis3P 4P
630/1250 A 33722 337251600 A 33723 33726
Communication optionChassis + Switch-disconnector
COM Modbus 33852 47485COM Digipact 33855 47489
207E5100.fm/17Schneider Electric
Catalogue numbers NT06 to NT16drawout switch-disconnectors (cont.)Switch-disconnector selection (cont.)
Chassis front connection
E46
440
3P 4P630/1600 A Top 33727 33733
Bottom 33728 33734
Front connection accessoriesVertical connection adapters 630/1600 A
E46
426
3P (3 parts) 336424P (4 parts) 33643
Cable lug adapters 630/1600 A
E46
427
3P (3 parts) 336444P (4 parts) 33645
Chassis rear connectionVertical connection
E46
429
3P 4P630/1600 A Top 33729 33735
Bottom 33730 33736Horizontal connection
E46
430
3P 4P630/1600 A Top 33731 33737
Bottom 33732 33738Rear connection accessories
E46
428
Interphase barriers
3P/4P (3 parts) 33768
Common accessories for front and rear connectionSpreaders
E46
431
630/1600 A 3P 336224P 33623
For front and horizontal rear connection
Cable lug kits
E47
820
240 mm2 3P (6 lug kit) 330134P (8 lug kit) 33014
300 mm2 3P (6 lug kit) 330154P (8 lug kit) 33016
207E5100.fm/18 Schneider Electric
Catalogue numbers NT06 to NT16 circuit breakers with neutral on the rightBasic circuit breaker selection
A 4 pole Masterpact circuit breaker with neutral on the right is described by the same catalogue numbers as a standard 4 pole one, except for the basic circuit breaker, which is specific.
Fixed circuit breakers with neutral on the rightType H1
4PNT06 630 42 47116NT08 800 42 47126NT10 1000 42 47136NT12 1250 42 47146NT16 1600 42 47156
Drawout circuit breakers with neutral on the rightType H1
4PNT06 630 42 47206NT08 800 42 47216NT10 1000 42 47226NT12 1250 42 47236NT16 1600 42 47246
207E5100.fm/19Schneider Electric
Catalogue numbers Communication bus accessories and Display Modules
Display modulesDMB300
E67
954
Monochrome display module Max. 4 breakers 50894
DMC300
E67
955
Color display module Max. 16 breakers 50895
Spare partsDMC300PCM: DMC300 memory card 50959
RS485 Modbus pre-wired systemRS485 Modbus junction block
E67
958
CJB306: 6 SubD 9 pins connectors junction block 50963
RS485 Modbus connector
E67
959
CSD309: 9 pins SubD with screw terminals 50964
RS485 Modbus cables
E67
960
CDM303: display module pre-wired cable, 3 m length 50960
E79
015
CCP303: Masterpact or Compact pre-wired cable (4 RS485 wires + 2 power wires) 3 m length 50961
E67
961
CCR301: RS485 roll cable (2 RS485 wires + 2 power wires) 60 m length 50965
Digipact Bus pre-wired systemData concentrator DC150
E79
014
Auxiliary supply voltage 110-240 V AC, 50/60 Hz and 115-125 V DC 50823
Junction block
E67
956
Junction block for internal Bus 50778
Cables
E67
957
Cable for internal bus 20-meter roll (0.75 mm2) 50779100-meter roll (0.75 mm2) 50780
ConverterRS485/RS232 (ACE909) 12 V DC power supply included 50786RS485/RS232 TSX SCA72RS485/Ethernet 174 CEV 300-10RS485/Ethernet (SMS compatible) 3050 EGW2
(1) see catalogue Telemecanique.(2) see catalogue Square D.
207E5100.fm/20 Schneider Electric
Catalogue numbers Order formMasterpact NT and NW
To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles
Basic device Quantity
Masterpact type NT, NWFrame size 06 to 63Sensor rating ACircuit breaker N1, H1, H2, H3, L1Switch-disconnector NA, HA, HFNumber of poles 3 or 4Option : Neutral on right sideType of device Fixed
Drawout with chassisChassis aloneDrawout without chassis
Micrologic control unitA - ammeter
2.0 A 5.0 A 6.0 A 7.0 AP - power meter
5.0 P 6.0 P 7.0 PH - harmonic meter
5.0 H 6.0 H 7.0 HTCE - external sensor (CT) for neutral + earth-fault protection
TCE - external sensor (CT) for double neutral protection (Micrologic P and H with 3-poles)
TCW - external sensor for SGR protectionRectangular sensor for earth-leakage protection
280 x 115470 x 160
LT - long-time rating plug (standard setting 0.4 to 1 x Ir)Low setting option 0.4 to 0.8 IrHigh setting option 0.8 to 1 IrLT OFF option
PTE - external voltage measurement inputAD - external power-supply moduleBAT - battery module
CommunicationCOM Digipact
ModbusEco COM Modbus
ConnectionHorizontal Top BottomVertical Top BottomFront Top BottomBare-cable connectors 4 x 240 mm2 + connector shield
NT-FC fixed
Vertical-connection adapters NT-FC, fixed, draw.Cable-lug adapters NT-FC, fixed, draw.Interphase barriers NT, NW-fixed, draw.Spreaders NT-fixed, drawoutDisconnectable front-connection adapter
NW-fixed
VO - safety shutters on chassis NT, NWVIVC - shutter position indication and locking
NW
Key for Micrologic control units:2.0 : basic protection (long-time + inst.)5.0 : selective protection (long-time + short-time + inst.)6.0 : selective + earth-fault protection (long-time + short-time + inst. + earth-fault)7.0 : selective + earth-leakage protection (long-time + short-time + inst. + earth-leakage)
LockingVBP - ON/OFF pushbutton lockingOFF position lockingVCPO - by padlocksVSPO - by keylocks Locking kit
withoutkeylocks
Profalux Ronis
1 lock 1 lock + 1 lock withsame key profile
2 locks (different key profiles) for NWVSPD - chassis locking in ''disconnected'' position
Locking kitwithoutkeylocks
Profalux Ronis
1 lock 1 lock + 1 lock withsame key profile
2 locks (different key profiles)Optional connected - disconnected - test position locking
VPEC - door interlock Latch on right-hand side of chassisLatch on left-hand side of chassis
VPOC - racking interlockIPA - cable-type door interlockIBPO - racking interlock between crank and OFF pushbutton for NWDAE - automatic spring discharge before breaker removal for NWVDC - mismatch protection
Indication contactsOF - ON/OFF indication contactsStandard 4 OF 6 A - 240 V AC (10 A - 240 V AC and low-level for NW)Alternate(replaces a standard contact)
1 OF low-level for NT Max. 4 qty
Additional 1 block of 4 OF for NW Max. 2 qtyEF - combined ''connected/closed'' contacts
1 EF 5 A - 240 V AC for NW Max. 8 qty1 EF low-level for NW Max. 8 qty
SDE - ''fault-trip'' indication contactsStandard 1 SDE 5 A - 240 V ACAdditional 1 SDE 5 A - 240 V AC
1 SDE low-levelProgrammable contacts 2 M2C contacts
6 M6C contactsCarriage switches low-level
6 A - 240 V ACCE - ''connected'' position Maxi. 3 for NT and NW qtyCD - ''disconnected'' position Maxi. 2 for NT and 3 for NW qtyCT - ''test'' position Maxi. 1 for NT and 3 for NW qtyAC - actuator for additional carriage switches qty
Remote operationRemote ON/OFF MCH - gear motor V
XF - closing voltage release VMX - opening voltage release VPF - ''ready to close'' contact low-level
6 A - 240 V ACBPFE - electrical closing pushbuttonRes - electrical reset optionRAR - automatic reset option
Remote tripping MN - undervoltage release VR - delay unit (non-adjustable)Rr - adjustable delay unit2nd MX - shunt release V
AccessoriesCDM - mechanical operation counterCB - auxiliary terminal shield for chassisCDP - escutcheonCP - transparent coverOP - blanking plateBrackets for mounting on backplates