Catalog Thomas Betts

182
Product Catalogue Lighting, Boxes, Cabinets, Conduits, Fittings & Accessories for Hazardous and Hostile Areas

description

Catalog Thomas Betts

Transcript of Catalog Thomas Betts

Page 1: Catalog Thomas Betts

Product CatalogueLighting, Boxes, Cabinets,

Conduits, Fittings & Accessories for Hazardous and Hostile Areas

Page 2: Catalog Thomas Betts

Welcome toThomas & Betts

Introduction

2

At Thomas & Betts, our focus is on improving your business

performance by providing practical, reliable electrical

products & services. To connect & protect for life. To solve

everyday problems in the area’s of Wire & Cable Management,

Cable Protection, Power Connection & Control and Safety.

Our extensive engineering, supply chain management

and technical sales support teams are committed to

understanding everything that impacts your ability to

accomplish your business objectives by reducing your total

cost of ownership.

Whether you are designing, installing, operating, maintaining

or owning an offi ce building, off-shore platform, hospital,

or a high speed train, power generating plant, machine

equipment or a manufacturing facility, Thomas & Betts

engineered products fi t and function in your application

while providing superior performance, sustainability, and

value throughout the project life cycle.

All our brands are built upon four product & service

solution platforms. Platforms that address you or your

customers’ critical electrical & lighting needs covering the

protection of data, energy, processes, assets and personal

safety. Beyond hi-performance application characteristics,

Thomas & Betts products, information and services facilitate

and speed up your time critical assembly, installation or

maintenance process.

Thomas & Betts in Europe:

Page 3: Catalog Thomas Betts

Contents

3

ContentsOil & Gas - Upstream Applications 4-5

Oil & Gas - Midstream Applications 6-7

Oil & Gas - Downstream Applications 8-9

Food & Beverage Applications 10

Chemical & Pharmaceutical Applications 11

World Standards & What They Mean 12-13

Zone Defi nitions - Onshore Gases & Vapours 14-15

Zone Defi nitions - Offshore Gases & Vapours 16

Zone Defi nitions - Dust 17

DTS - Product Marking Guide 18-19

Kopex Ex - Product Marking Guide 20-21

Index of Ingress Protection 22

Photometry 23

Ex Lighting Fittings 24-25

Lighting Fittings - Selection Guide 26-27

Ex Lighting

XFF Range - Ex d 28-29

XFP Range - Ex de 30-31

XEL Range - Ex d 32-33

XEP Range - Ex de 34-35

XF Range - Ex de 36-37

XFB / XFL Range - Ex n 38-39

XDF Range - Ex nA 40-41

EVS Range - Ex de 42-43

EVN Range - Ex n 44-45

EVD Range - Ex t 46-47

ESB Range - Ex de 48-49

Ex Emergency and Escape Lighting

XFF-EM Range - Ex d 50-51

XFP-EM Range - Ex de 52-53

XEL-BAES Range - Escape Lighting - Ex d 54-55

EVS-EM Range - Ex de 56-57

EVS-EMA Range - Ex de 58-59

EVN-EM Range - Ex n 60-61

EVN-EMA Range - Ex n 62-63

EVD-EM Range - Ex t 64-65

EVD-EMA Range - Ex t 66-67

ESB-EM Range - Ex de 68-69

Industrial Lighting 70-71

FF Range 72-73

EL Range 74-75

SF / QF / HF Range 76-77

EVT Range 78-79

EST Range 80-81

FB / FL Range 82-83

HF Range 84-85

Industrial Emergency Lighting

FR-EM / FF-EM Range 86-87

EVT-EM Range 88-89

EVT-EMA Range 90-91

EST-EM Range 92-93

Lighting Accessories & Spare Parts 94-99

Lamps Guide 100-103

Ex Boxes & Enclosures 104-105

Boxes & Enclosures - Selection Guide 106-107

XBL Range - XB100 Junction Boxes - GRP 108-109

XBL Range - Junction Boxes - GRP 110-111

XBL Range - Instrumentation Boxes - GRP 112-113

XBL-A Range - Control Boxes - GRP 114-115

XB Range - Instrumentation Boxes - Aluminium 116-117

XB-A Range - Control Boxes - Aluminium 118-119

XBi Range - Instrumentation Boxes - Stainless Steel 120-121

XBi-A Range - Control Boxes - Stainless Steel 122-123

GUV Range - Junction Boxes - Aluminium 124-125

EFDC / SRC / XMC Range - Control Boxes - Aluminium 126-127

EJB Range - Custom Built Panels - Aluminium 128-129

Box Accessories & Spare Parts 130-131

Conduit Systems 132-133

Conduit Fittings - Selection Guide 134-135

EXB / EXBB Range 136-137

EXBQM / EXPQA Range 138-139

EXLB / EXLT / EXLH / EXBBT / EXLHC Range 140-141

EXSB / EXST / EXSH / EXSBBT / EXSHC Range 142-143

G1 Gland / 90º Elbow Gland 144-145

Group II Gland 146-147

Universal & Universal Swivel Gland 148-149

PA / PAP NPT Range 150-151

PE / PEP ISO Range 152-153

PA-B / PAP-B NPT & ISO Range 154-155

XP Flex Range 156-157

Enlargers, Reducers & Thread Convertors 158-161

Ex d Stopping Plugs 162-163

Ex e Stopping Plugs 164-165

Accessories 166-167

INDEX 168-177

Thomas & Betts Worldwide Industrial Capabilities 178-179

Key of Symbols 180

Thomas & Betts • www.tnb-hazardous.com

Page 4: Catalog Thomas Betts

4

Thomas & Betts • www.tnb-hazardous.com

Oil & Gas - Upstream Applications

The oil and gas market is split into three sectors Upstream,

Midstream and Downstream. Upstream consists of Exploration

and production both these areas offer very distinct and unique

challenges to people and equipment working within them.

Firstly there are offshore applications such as the drilling rigs

and production platforms; these are always open to extreme

weather conditions so equipment used here needs to be able to

withstand a salty environment. This is achieved through either

manufacturing product from stainless steel as is the

case for the Kopex-Ex conduit glands, and DTS enclosures, or

by ensuring that the product is coated or painted to withstand

marine environments as in the DTS XFF fl uorescent lighting.

Equipment in offshore applications also needs to be

hardwearing and easy to maintain as production downtime

can be extremely costly for example FPSO (Floating Production

Storage and Offl oading) vessel can produce up to 200,000

barrels of crude oil per day at approx $80 to $90 per barrel.

A breakdown would result in the vessel producing a loss of

revenue of over $700,000 and hour.

Industry Overview Approvals / Characteristics

Product Selection Issues• Salt water corrosion (offshore platforms)• Oil and chemical resistance (Drilling rig MUD)• Extreme ambient temperature (High temperature

Middle East / low temperature Russia)• Protection level• Connectivity to other pieces of equipment• Consequence of down time• Approval level required (Ex e, Ex d, etc.)• Approval specification required ATEX, IECEx,

UL, GOST, etc.• Where product will be positioned, e.g. Zone 1 or Zone 2

Page 5: Catalog Thomas Betts

Oil & Gas - Upstream Applications

5

Thomas & Betts • www.tnb-hazardous.com

EXL Conduit 140 EJB Range 128 XFF Range 28

Related Products

Stopping Plugs 164

This has led to Kopex-Ex conduit systems being used in many

offshore applications to protect critical data and power cables

across these massive vessels, whether it is data cables from

a gas detector or the cable protection on a power transmission

unit, Kopex-Ex offers a whole range of products that are

tested and approved to many of the world standards.

DTS lighting on the other hand offers easy maintenance with

removable gear trays allowing the entire gear tray to be removed

and maintenance to be carried out quickly and safely. In fact

on the XFF Exd luminaries the components such as ballasts and

tubes are standard so the stocking and sourcing of spare parts is

made easy. Again essential to an offshore vessel.

Secondly onshore applications can also be split into exploration

and production. However onshore is more economically viable

than offshore with some wells only producing as few as a dozen

barrels of oil a day. However, they can become extremely

large with wells being networked together to produce up to

a million barrels of oil a day.

This brings with it a whole new series of challenges to be overcome.

Firstly the drilling rigs tend to be mobile with motors and pumps often

mounted on skids for easy transportation. This can lead to issues of

connectivity for which Kopex-Ex have a range of thread converters

in a variety of materials and approvals ready to resolve the problem.

Secondly with so many rigs in a network there is a massive

monitoring operation to be done to ensure that the fl ow of all

the rigs is ongoing and consistent. This is where the DTS range of

instrumentation boxes can offer great fl exibility as they can be

custom made to meet exact specifi cations.

The need to maintain fl ow also leads to the need for motors and

controls on the well heads themselves often referred to as “Christmas

Trees.” These are under high pressure and must be able to withstand

up to 1400 bar this is a critical area and has to be monitored closely

to ensure that pressure do not fl uctuate this is done by the valves

within the wellhead controlled by motors. DTS EJB enclosures can be

custom built to control these valves and at the same time monitor

the pressures and relay it back to the central control point.

Page 6: Catalog Thomas Betts

6

Oil & Gas - Midstream Applications

Midstream relates to the transportation, storage and partial

processing of crude oil and gas from the wellheads to the refi ning

plants. This brings a different set of challenges to overcome.

This all relates to the fact that what is pumped out of the well

is not pure and often contains a mixture of oil, gas, water

and often sand which fi rstly need to be separated off from each

other before being shipped or piped to a storage facility.

This can be done in a variety of ways depending on the type of oil

or gas that the well is pumping and can often take up to 4 processes

before the commodity is separated out ready for piping or

shipping. These processes require energy and this energy is often

created from the commodity itself by the utilization of the gas.

Once the separating has been completed, the commodity can

then be moved to storage. In the case of an offshore rig this

separating is often done on shore away from the rig then

pumped to the storage depots. In the case of the FPSO vessels

it is all done on board and the oil transferred to tankers at

sea for delivery to storage depots.

Industry Overview Approvals / Characteristics

Product Selection Issues• Salt water corrosion (Tankers)• Extreme ambient temperature (High temperature Middle East / low temperature Russia)• Protection level• Consequence of down time• Approval level required (Ex e, Ex d, etc.)• Approval specification required ATEX, IECEx, UL, GOST etc• Where product will be positioned, e.g. Zone 1 or Zone 2

Thomas & Betts • www.tnb-hazardous.com

Page 7: Catalog Thomas Betts

Oil & Gas - Midstream Applications

7

EFDC Range 126 EVS Range 42

Related Products

This is also the point when all metering needs to take place

to calculate invoices and taxes today. This is done very

accurately measuring not only the amount of oil produced but

also the density, viscosity, pressure and temperature, and in

the case of gas, the amount of water vapour.

Oil is often pumped direct to the oil refi nery which is where the

down stream operation starts but often needs to go through

a series of pumps to get the required pressure.

With the DTS and Kopex-Ex range of products, Thomas & Betts can

offer a range of products and services to meet the demands of

Midstream Oil and gas markets. The DTS range of lighting products

is manufactured to meet ATEX and IECEx standards. Designed

to be robust to meet the vigors of the environment whether it is on

oil tankers where the XFF product is ideal. To storage depots

where the EVS range of fl uorescents is often preferred. Added to

this all the fl uorescent lighting has been designed with the

installer and maintenance people in mind with removable gear

trays for easy safe installation and maintenance.

DTS also offers a wide range of standard and custom made

instrumentation boxes often used in the monitoring

equipment to relay signals from the sensors back to the central

control systems. As well as a range of standard confi guration

for control boxes including “Emergency Stop” and “On - Off”

to control motors etc. All of these are available in GRP,

aluminum and Stainless steel 316 therefore meeting any

environmental requirement.

Kopex-Ex conduits are used in many applications including to

protect the critical data cables feeding the information from

sensors to the instrumentation boxes as well as being used

on the compressors protecting the wiring where temperatures

can reach over 100ºC.

Thomas & Betts • www.tnb-hazardous.com

EXL Conduit 140 Stopping Plugs 164

Page 8: Catalog Thomas Betts

8

Oil & Gas - Downstream Applications

The term downstream relates to the processing and delivery of

fi nished carbon related product to the end-user. This covers a whole

range of applications from Refi ning to petrol stations.

There are over 700 refi neries globally all competing to supply

fi nished carbon based products to local and international markets.

The products refi ned are varied including:

• Transportation fuels

LPG, gasoline, jet fuel, diesel, gas oil and bunker fuel.

• Petrochemical feedstocks

LPG, naphtha and aromatics.

• Energy sources

LPG, kerosene, heating oil and fuel oil.

• Specialities

Lubricants, bitumen, coke, solvents and waxes.

• Petrochemical feedstocks

Synthetic fi bres (nylon), plastics (polyethylene, PVC).

Industry Overview Approvals / Characteristics

Product Selection Issues• Continual Movement (CCTV)• Extreme ambient temperature (High temperature

Middle East / low temperature Russia and rail tankers)• Protection level• Consequence of down time• Approval level required (Ex e, Ex d, etc.)• Approval specification required ATEX, IECEx,

UL, GOST, etc.• Where product will be positioned, e.g. Zone 1 or Zone 2

Thomas & Betts • www.tnb-hazardous.com

Page 9: Catalog Thomas Betts

Oil & Gas - Downstream Applications

9

XF Range 36

Related Products

The refi ning process is in four stages, fi rstly distillation which

separates it into 5 product sectors LPG, Naphtha, Kerosine, Gas,

Oil, and Atmospheric residue, this is done using high

temperature. The higher the temperature the higher the quality

of the product.

The second stage is the upgrading or reforming. This stage

is used to change the product at a molecular level for

example changing the low octane version of Naphtha to high

octane which can be blended into gasoline.

Stages three and four are about treating the product to

remove impurities such as sulphur and blending the refi ned

product into distinct products for the market.

The fi nal stage of the downstream process is delivery to the

market which involves storage and transportation. For example

in the case of aviation fuel this can be shipped direct to

airports by road or rail where it is stored, before transferring

to tanker trunks for the refuelling of aircraft.

All the stages in the downstream operation have different

requirements to ensure safety of personnel and the quality of

the end product. DTS and Kopex-Ex products are both used in

this area whether it is the XF fl oodlight range or EVS

fl uorescent range. They are all designed for easy maintenance.

There is also a range of instrumentation boxes either with

standard confi gurations or custom made to end-user

requirements, all of which are essential within a refi nery where

sensors play a key part on the process to ensure quality.

Kopex-Ex also plays a key part within the downstream market

not just used to protect the sensor cables but also for

security on CCTV all the way through to the cable protection

on rail tankers and tanker trucks.

Thomas & Betts • www.tnb-hazardous.com

EVS Range 42EXL Conduit 140 Stopping Plugs 164

Page 10: Catalog Thomas Betts

10

Food Manufacture - Explosion Proof (Dust) Beverage Manufacture - Explosion Proof (Vapour)

Food Industry

Thomas & Betts offer a range of products for the food

processing market, including products for use in areas

where stainless steel is preferred as well as areas classed as

hazardous. Thomas & Betts can offer stainless steel

control stations for use on automated food processing and

packaging machines as well as lighting specifi cally designed

for use in dust fi lled atmospheres such as fl our mills or

other places where the risk of explosion is considered to

be extremely high.

Beverage Industry

Thomas & Betts has a range of products designed for use

in all beverage production sectors in the malting,

brewing, wine, spirits or soft drink business. DTS can supply

lighting products to suit the needs of hazardous areas

where explosive gases may occur or in areas where

cleanliness is required.

Food & Beverage Applications

Thomas & Betts • www.tnb-hazardous.com

Page 11: Catalog Thomas Betts

Pharmaceutical Applications

11

Chemical Engineering - Explosion Proof Pharmaceutical Production - Explosion Proof

Chemical Industry

The chemical industry produces very diverse products,

everything from fertilizers to explosives such as

nitroglycerin. The processes used in this industry mean that

there are lots of applications for the DTS lighting and

box ranges. DTS can offer standard or custom built products,

whether it is for a process control station or for

instrumentation boxes linking sensors back to central

control panels.

Pharmaceutical Industry

The Thomas & Betts range of products and solutions is

ideal for use in the pharmaceutical Industry. Whether

it is upstream in the primary production stage or

downstream in the packing stage. Many of the processes

and applications used in these areas require approvals

to hazardous area standards making stainless steel junction

and control boxes ideal.

Chemical & Pharmaceutical Applications

Thomas & Betts • www.tnb-hazardous.com

Page 12: Catalog Thomas Betts

12

Standards and what they mean

In this Section we will outline the different Standards used

throughout the world and what it means for products

specifi ed for use in Hazardous Areas. Below is a map of the

world which illustrates the Standards that are generally used in

these regions.

The ATEX Europe Directives 94/9/EC

ATEX requires employers to eliminate or control risks from

dangerous substances and to classify areas where explosive

atmospheres may occur into zones, as laid down in regulations.

ATEX Directives are designed to protect employees, the public

and the environment from accidents owing to explosive

atmospheres and since July 1st 2006 all existing sites, as well as

new sites, must be fully ATEX compliant.

Directive ATEX100a applies to equipment suppliers and

manufacturers and ATEX137 applies to end users. These

directives compliment each other, but have different purposes.

ATEX100A covers both electrical and non-electrical products

intended for use in hazardous areas, including mechanical

equipment. The Directive came into existence in 2003 and

products sold within the European Union designed for use in

hazardous areas must have ATEX certifi cation and bear the

World Standardsand what they mean

ATEX marking on the product or on a certifi cate plate. The

obligation is placed upon the manufacturer or supplier of the

product and the intention is to facilitate free movement of

goods within the EU.

Declaration of Conformance

This has to be issued by the supplier for every order which is

to be installed in a hazardous area. This document has to

show that the equipment supplied complies with the latest

harmonized standard.

UL CSA

Product Approvals

IECEx GOST INMETROATEX

Thomas & Betts • www.tnb-hazardous.com

Page 13: Catalog Thomas Betts

13

World Standards

IECEx (International Scheme)

The IECEx scheme is an international certifi cate of

conformance for products used in a hazardous area.

This scheme provides:

a) A single certifi cation of conformity for manufacturers to

comply that includes:

i) Testing and assessment of products to a standard

including a full test report.

ii) Ongoing surveillance of manufacturers premises.

b) A fast-track process for countries where regulations still

require the issuing of national Ex certifi cates or approvals.

This scheme is in the process of being adopted by all the

known standards across the world but are all working to

various time scales.

UL (America) & CSA (Canada)

The American and Canadian standards are the only ones to

have different classifi cations and locations. ATEX & IECEx

work to Groups and Zones whereas the NEC & CEC works

to Classes and Divisions, there is no direct comparison

between the two. This means that it is imperative that the two

standards are not inter-changed within an area.

GOST (Russia)

GOST follows similar rules to that of IECEx as far as the

breakdown of the zones and other criteria are concerned.

However, the requirements for this country mean that

separate GOST markings are required on the product.

GOST is divided into GOST (R) which is the standard for Russian

Federation and GOST (K) that cover Kazakhstan.

Electrical materials for use in potentially explosive

atmospheres must conform to two major certifi cation

standards: IEC/CENELEC and NEC

The IEC (International Electrotechnical Commission) standards

are accepted in practically all countries. They are identical to

the European CENELEC standards.

The NEC (National Electrical Code) is mandatory in the

United States. The 1996 version, art. 505, takes up the IEC

designations for gas, temperature classes for materials and

zone defi nition.

Gases and vapours classifi cation

Gases are divided into four groups in the NEC (National

Electrical Code) and three groups for IEC/CENELEC. The groups

display the same hierachy of classifi cation of gases and vapour.

(See table on page 20).

Temperature classifi cation

The IEC and the NEC have also defi ned a temperature

classifi ciation for material used in zones at risk of explosion.

(See table on page 21).

Thomas & Betts • www.tnb-hazardous.com

Page 14: Catalog Thomas Betts

FOR GASES & VAPOURS ZONE 0 Permanent / Frequent Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is present continuously or for long periods, or frequently.

ZONE 1 Ocassional Site where an atmosphere consisting of a mixture of air and inflammable substances in the form of gas, vapour or mist is likely to arise occasionally during normal operation.

Zones for Onshore Gases & Vapours

Zone Defi nitions Onshore Gases & Vapours (as per ATEX 60079-10)

14

Thomas & Betts • www.tnb-hazardous.com

Page 15: Catalog Thomas Betts

SAFETY ZONELow Explosion Risk

ZONE 2 Gas Irregular / Short Duration Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

15

Zones Explained

Thomas & Betts • www.tnb-hazardous.com

Page 16: Catalog Thomas Betts

16

Zone Defi nitionsOffshore Gases & Vapours (as per ATEX 60079-10)

FOR GASES & VAPOURS ZONE 0 Permanent / Frequent Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is present continuously or for long periods, or frequently.

SAFETY ZONELow Explosion Risk

ZONE 1 Ocassional Site where an atmosphere consisting of a mixture of air and inflammable substances in the form of gas, vapour or mist is likely to arise occasionally during normal operation.

ZONE 2 Gas Irregular / Short Duration Place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Zones for Offshore Gases & Vapours

Thomas & Betts • www.tnb-hazardous.com

Page 17: Catalog Thomas Betts

17

Zones Explained

FOR DUST

ZONE 20 Permanent / Frequent Area in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods, or frequently.

SAFETY ZONENo Explosion Risk

ZONE 21 Occasional Area in which an explosive atmosphere, in the form of a cloudof combustible dust in air is likely to occur, occasionally, in normal operation, ocassionally.

ZONE 22 Dust Irregular / Short Duration Area in which an explosive atmosphere, in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Zone Defi nitions Dust (as per ATEX 60079)

Zones for Dust

Thomas & Betts • www.tnb-hazardous.com

Page 18: Catalog Thomas Betts

18

DTS - Classifi cation of equipmentfor use in potentially explosive atmospheres

Ex II 2 G Exe IIC T6/ 2 D Extb IIIC T85C IP66

U=415V/50Hz12/0116422

Gases or vapours

Subdivision of gases and vapours

Typicalzones

Temporary behaviour offlammable substances inhazardous places

Flammablesubstances

MethaneDusts

Required marking for installation

equipment equipmentgroup protection level

IIA

IIB

IIC

is present continuously or zone 0 II Gafor long periods or frequently

is likely to occur in normal zone 1 II Gboperation occasionally

is not likely to occur in normalopration but, if it does occur, will zone 2 II Gcpersist for a short period only

is present continuously or for zone 20 III Dafor long periods or frequently

is likely to occur in normal zone 21 III Dboperation occasionally

it is not likely to occur in normaloperation but, if it does occur, zone 22 III Dcwill persist for a short period only

- mines I Ma

- mines I Mb

Dusts

GasesVapours

Apparatus maybe used in group

Dust

IIIA Combustible FlyingsIIIB Non-Conductive DustIIIC Conductive Dust

ammonia ethyl alcohol galsoline acetaldehydemethane cyclohexane n-hexaneethane n-butanepropane

town gas, ethylene ethylene ethyl-etheracrylnitril ethylene glycol

oxide

sulphide ofethinehydrogencarbon(acetylene)

LCIE 11 ATEX 3050 X(Certification Number)

(Gas) (Dust)

(Serial No.)

Classification of hazardous areas European/IEC or NEC classifications

Product stamp detail

XB10-SI

19-21, avenue Henri Baudelet77831 Ozoir-la-Ferriere (France)

0081II

Thomas & Betts • www.tnb-hazardous.com

Page 19: Catalog Thomas Betts

DTS Product Marking Guide

All applications

Control stations, motors, fuses,switchgear, power electronics

Installation materials, motors, luminaries

Measurement and control, automationtechnology, sensors, actuators

Switch- and control cupboards,analyse-apparatus, computers

Coils of motors or relays, solenoid valves

Transformers, relays, control stations,magnetic contactors

Capacitors, transformers

Product use depending on temperature class (T1 - T6).

See at the top - only for zone 2

Temperature Class (T) / Ignition Temperature

Restrictionfor using apparatus

Requirements Marking

Equipment without

Equipment with

-restriction

special condition Xmay be noted

Ex component,which is notintended to beused aloneand requiresadditionalcertification before

U

being used inhazardous area

-

Ex d

Ex e

Ex i

Ex p

Ex m

Ex o

450º

Ex q

Ex n

60079-0

60079-1

60079-7

60079-11

60079-2

60079-18

60079-6

60079-5

60079-15

General requirements

Flameproof enclosure

Increased safety

Intrinsic safety

Pressurisation

Encapsulation

Oil immersion

Powder filling

‘Non sparking’

For use in zone 0, 1, 2 / for use in zone 1, 2 Ex t 60079-31Dust atmospheres

IIA T1 Acetone 735ºIIA T1 Ammonia 630º

IIB T1 Carbon Monoxide 605ºIIA T1 Bensene 560º

IIC T1 Hydrogen 560ºIIA T1 Methane 537ºIIA T1 Toluene 535ºIIA T1 Styrene 490º

IIA T1 Propane 470ºIIA T1 1-Butene 455º

IIB T1 Butadiene 430º

IIB T2 Ethylene 425ºIIA T2 Butane 372ºIIA T2 Ethanol 363º

IIA T2 Butylalcohol 359ºIIB T2 Dimetylether 350º

IIC T2 Acetylene 305º

IIA T3 Nafta 290ºIIA T3 Hydrogen Sulphide 270º

IIA T3 Cyclohexane 259ºIIA T3 Hexane 233º

IIA T3 Heptane 215ºIIA T3 Kerosene 210º

IIA T3 Dekane 201º

IIB T4 Diethyl Ether 160º

IIC T6 Carbon Disulphide 95º

Application Marking EN/IEC standardType of protection

Protection technique

300º

200º

135º

100º

85º

T1 > 450º

T2 > 300º

T3 > 200º

T4 > 135º

T5 > 100º

T6 > 85º

600º

750º

19

Thomas & Betts • www.tnb-hazardous.com

Page 20: Catalog Thomas Betts

20

Kopex-Ex - Classifi cation of equipmentfor use in potentially explosive atmospheres

CMPL I M2/II 2GD Exde I Mb Exde IIC Gb Extb IIIC Db

CLI.Div1.ABCD .CLII.Div1.EFG.

Gases or vapours

Subdivision of gases and vapours

Typicalzones

Temporary behaviour offlammable substances inhazardous places

Flammablesubstances

MethaneDusts

Required marking for installation

equipment equipmentgroup protection level

IIA

IIB

IIC

is present continuously or zone 0 II Gafor long periods or frequently

is likely to occur in normal zone 1 II Gboperation occasionally

is not likely to occur in normalopration but, if it does occur, will zone 2 II Gcpersist for a short period only

is present continuously or for zone 20 III Dafor long periods or frequently

is likely to occur in normal zone 21 III Dboperation occasionally

it is not likely to occur in normaloperation but, if it does occur, zone 22 III Dcwill persist for a short period only

- mines I Ma

- mines I Mb

Dusts

GasesVapours

Apparatus maybe used in group

Dust

IIIA Combustible FlyingsIIIB Non-Conductive DustIIIC Conductive Dust

ammonia ethyl alcohol galsoline acetaldehydemethane cyclohexane n-hexaneethane n-butanepropane

town gas, ethylene ethylene ethyl-etheracrylnitril ethylene glycol

oxide

sulphide ofethinehydrogencarbon(acetylene)

(Product stamp detail)

(Class & Divisions)

Classification of hazardous areas European/IEC or NEC classifications

Product stamp detail

CLI (Class I), Div1 Where ignitable concentrations of flammable gases, vapors or liquids are present within the atmosphere under normal operation conditions. CLI (Class I), Div2 Where ignitable concentrations of flammable gases, vapors or liquids arepresent within the atmosphere under abnormal operation conditions.Class I Areas Group A: Acetylene / Group B: Hydrogen / Group C: Propane & Ethylene / Group D: Benzene, Butane & Propane.

CLII (Class II), Div1 Where ignitable concentrations of combustible dusts are present within the atmosphere under normal operation conditions. CLII (Class II), Div2 Where ignitable concentrations of combustible dusts are present within the atmosphere under abnormal operation conditions. Class II Areas Group E: Metal Dust / Group F: Carbon & Charcoal / Group G: Flour, Starch, Wood & Plastic.

Thomas & Betts • www.tnb-hazardous.com

Page 21: Catalog Thomas Betts

Kopex-Ex Product Marking Guide

IECEx SIRA09.0103 X

All applications

Control stations, motors, fuses,switchgear, power electronics

Installation materials, motors, luminaries

Measurement and control, automationtechnology, sensors, actuators

Switch- and control cupboards,analyse-apparatus, computers

Coils of motors or relays, solenoid valves

Transformers, relays, control stations,magnetic contactors

Capacitors, transformers

Product use depending on temperature class (T1 - T6).

See at the top - only for zone 2

Temperature Class (T) / Ignition Temperature

Restrictionfor using apparatus

Requirements Marking

Equipment without

Equipment with

-restriction

special condition Xmay be noted

Ex component,which is notintended to beused aloneand requiresadditionalcertification before

U

being used inhazardous area

-

Ex d

Ex e

Ex i

Ex p

Ex m

Ex o

450º

Ex q

Ex n

60079-0

60079-1

60079-7

60079-11

60079-2

60079-18

60079-6

60079-5

60079-15

General requirements

Flameproof enclosure

Increased safety

Intrinsic safety

Pressurisation

Encapsulation

Oil immersion

Powder filling

‘Non sparking’

For use in zone 0, 1, 2 / for use in zone 1, 2 Ex t 60079-31Dust atmospheres

IIA T1 Acetone 735ºIIA T1 Ammonia 630º

IIB T1 Carbon Monoxide 605ºIIA T1 Bensene 560º

IIC T1 Hydrogen 560ºIIA T1 Methane 537ºIIA T1 Toluene 535ºIIA T1 Styrene 490º

IIA T1 Propane 470ºIIA T1 1-Butene 455º

IIB T1 Butadiene 430º

IIB T2 Ethylene 425ºIIA T2 Butane 372ºIIA T2 Ethanol 363º

IIA T2 Butylalcohol 359ºIIB T2 Dimetylether 350º

IIC T2 Acetylene 305º

IIA T3 Nafta 290ºIIA T3 Hydrogen Sulphide 270º

IIA T3 Cyclohexane 259ºIIA T3 Hexane 233º

IIA T3 Heptane 215ºIIA T3 Kerosene 210º

IIA T3 Dekane 201º

IIB T4 Diethyl Ether 160º

IIC T6 Carbon Disulphide 95º

Application Marking EN/IEC standardType of protection

Protection technique

(Certification Number)

300º

200º

135º

100º

85º

T1 > 450º

T2 > 300º

T3 > 200º

T4 > 135º

T5 > 100º

T6 > 85º

600º

750º

New Marking - EPL’s (Explosion Protection Levels) The introduction of the EPL’s and changes in the EN 60079 series standard has introduced new marking requirements.

21

Thomas & Betts • www.tnb-hazardous.com

Page 22: Catalog Thomas Betts

Index of Ingress Protection

22

IPxx suitability ratings are a system for classifying the

degree of protection provided by enclosures of electrical

equipment. The higher the number, the greater the

degree of protection, in accordance with standards

IEC 60529 and EN 60529.

Protection standrards

• Protection against solid bodies

• Protection against liquids

• Protection against impact a per EN 50102 standard

Protection against Solid Bodies Protection against Liquids

0

1

2

03

04

05

6

0

1

2

3

4

5

6

7

8

9

No protection

Protected against solid bodies of 50mm and greater, (e.g. accidental contact with the hand)

Protected against solid bodies of 12.5mm and greater, (e.g. accidental touch by fingers)

Protected against solid bodies of 2.5mm and greater, (e.g. tools and wires)

Protected against solid bodies of 1mm or greater, (e.g. thin tools and fine wires)

Protected against dust - limited ingress (no harmfull deposits)

Totally protected against dust(Dust-tight)

No protection

Protected against vertically falling drops of water (condensation)

Protected against drops of water falling up to 15º from the vertical

Protected against drops of water falling up to 60º from the vertical

Protected against splashing water from all directions

Protection against jets of water from all directions

Protection against powerful jets of water from all directions

The fi rst digit stands for protection against

solid bodies

The second digit stands for protection

against water

IP Classifi cation

Protected against the effects of temporary immersion in water

Protected against the continuous effects of immersion in water havingregard to specific conditions

IP69k Automotive standard DIN40050 signifies resistance to high pressure jets (up to 80bar) from any angle

Index ofIngress Protection

IP 6 77 =

Thomas & Betts • www.tnb-hazardous.com

Page 23: Catalog Thomas Betts

Example: For a point situated at 60º from the vertical

of a luminaire, the luminous intensity is 27.78 cd in the

lamp’s transverse plane and 26.76 cd in the lamp’s

longitudinal plane (for a 1000 lm fl ux).

Note: the curve ‘integrates’ the lighting fi tting effi ciency, there

is no need to make corrections. However it is neccessary to

multiply the intensity given by the curve by the coeffi cient to

obtain the actual luminous fl ux of the chosen source.

Determination of the illuminance at a given point

A pinhole source of light placed on S at a distance d from a

point P on a surface plane creates an illuminance Ep whose

value is: Ep = where α is the angle forming the

direction Sp from which the luminous intensity comes with the

perpendicular n at P.

This formula is universal and allows the expression of values

of illuminance in horizontal, vertical or any other plane. The

example for a horizontal plane calculation is usually used for

practical reasons. In that case one speaks of a light source

situated at a height h above the plane. The illuminance at the

point P is expressed by the formula: EP =

Photometry

23

Photometric Units and Levels

• Luminous Flux: Symbol F

The amount of light emitted by a source by unit of time:

it’s the fl ow of light. This level is used to rate lamps

photometrically and is epressed in lumen (lm).

• Luminous Intensity: Symbol I

Is the quantity of luminous fl ux in a specifi c direction. The

unit of measurement is the Candela (cd). Values on the

photometric curves are expressed in candelas.

• Illuminance

The quantity of light falling on a unit area, expressed by

the formula: E= F/S, where F is the level of the luminous

fl ux reaching the surface and S is the area of that receiving

surface. The unit is lux (lx) which represents the level

of one lumen falling on a surface of one square metre.

When the surface S is large it is expressed as average

illuminance on the surface. This measurement is important

as it can be measured by a light meter and allow fi ttings

to be controlled.

Photometric Curves

A visual method of showing the luminous intensity distribution

of a lighting fi tting. Values are in candelas (cd). To enable

comparisons to be made for different fi ttings, the curve is

drawn for a 1000 lumen fl ux.

PhotometryPhotometric Data Explained

lcos α d2

lcos3 α h2

h

P

α

S

n

P

d

100110100

20 10 0 10 20

110

80

70

60

50

40

30

9090

80

70

60

50

40

30

0 . 6 8 H + 0 . 1 0 T

255075

100125150175200

Thomas & Betts • www.tnb-hazardous.com

Page 24: Catalog Thomas Betts

Ex Lighting Fittings

2624

Thomas & Betts • www.tnb-hazardous.com

Page 25: Catalog Thomas Betts

Ex Lighting Fittings

25

Thomas & Betts • www.tnb-hazardous.com

Page 26: Catalog Thomas Betts

26

Ex Lighting Range

Ex Lighting Fittings - Selection Guide

Thomas & Betts • www.tnb-hazardous.com

XFP Page 30

XEL Page 32

XEP Page 34

XFF Page 28

XDF Page 40

EVS Page 42

EVN Page 44

XF Page 36

EVD Page 46

ESB Page 48

Prot

ectio

n Ty

peG

asG

roup

sD

ust

Gro

ups

Zo

nes

Page 27: Catalog Thomas Betts

Ex Lighting Fittings - Selection Guide

27

Ex Emergency & Escape Lighting Range

Thomas & Betts • www.tnb-hazardous.com

XFP-EM Page 52

XEL-BAES Page 54

EVS-EM Page 56

XFF-EM Page 50

EVN-EM Page 60

EVN-EMA Page 62

EVD-EM Page 64

EVS-EMA Page 58

EVD-EMA Page 66

ESB-EM Page 68

Page 28: Catalog Thomas Betts

Approved to: EN60079-0, 60079-1, 60079-31 EC TYPE Examination Certificate:INERIS 11 ATEX 0051XEx II 2 GEx d IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (All Polycarbonate tubes)Ex d IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass tubes)Ex d IIB T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass versions - XFR140, XFR165, XFF240 and XFF265)Ex II 2 DEx tb IIIC T80°C Db IP66Glow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +55ºC

Certifi cation & Standards

• Manufactured from marine grade aluminium• All components mounted on slide gear tray for easy installation and maintenance• Standard components used inside body allowing reduced maintenance costs• Available in Glass for paint shop and other spray applications for easy cleaning• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

28

XFF RangeTubular fl uorescent fi tting

Thomas & Betts • www.tnb-hazardous.com

Page 29: Catalog Thomas Betts

EXL Conduit 140

Ex lighting - XFF Range

Wiring Nominal Dimensions (mm)

Type Configuration Rating (W) Current (A) Diffuser A B Weight (kg)

XFR120-0G000 3 Wire 1 x 18 0.15 Polycarbonate 780 565 5.5

XFR136-0G000 3 Wire 1 x PL36 0.2 Polycarbonate 1385 1170 6

XFR140-0G000 3 Wire 1 x 36 0.2 Polycarbonate 1385 1170 9

XFR155-0G000 3 Wire 1 x PL55 0.25 Polycarbonate 1690 1475 6

XFR165-0G000 3 Wire 1 x 58 0.35 Polycarbonate 1690 1475 11

XFF220-0G000 3 Wire 2 x 18 0.3 Polycarbonate 780 565 6.5

XFF236-0G000 3 Wire 2 x PL36 0.4 Polycarbonate 1385 1170 6.5

XFF240-0G000 3 Wire 2 x 36 0.4 Polycarbonate 1385 1170 10

XFF255-0G000 3 Wire 2 x PL55 0.5 Polycarbonate 1690 1475 6.5

XFF265-0G000 3 Wire 2 x 58 0.5 Polycarbonate 1690 1475 12

XFR120V-0G000 3 Wire 1 x 18 0.15 Glass 780 565 7

XFR136V-0G000 3 Wire 1 x PL36 0.2 Glass 1385 1170 8

XFR140V-0G000 3 Wire 1 x 36 0.2 Glass 1385 1170 17

XFR155V-0G000 3 Wire 1 x PL55 0.25 Glass 1690 1475 8

XFR165V-0G000 3 Wire 1 x 58 0.35 Glass 1690 1475 17

XFF220V-0G000 3 Wire 2 x 18 0.3 Glass 780 565 8.5

XFF236V-0G000 3 Wire 2 x PL36 0.4 Glass 1385 1170 8.5

XFF240V-0G000 3 Wire 2 x 36 0.4 Glass 1385 1170 18

XFF255V-0G000 3 Wire 2 x PL55 0.5 Glass 1690 1475 8.5

XFF265V-0G000 3 Wire 2 x 58 0.5 Glass 1690 1475 20

Technical Specifi cations

29

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 162

EnclosureEnd caps according to standard: EN1706:EN AC-AISi12(Fe) DF or EN AC-AISi10Mg(a) DF marine grade aluminium Yellow polyurethane paint RAL 1003IP66 / IP67 IEC60529 if installed to manufacturersinstructionsFixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesElectronic ballast:AC/DC 220V-240V, 50-60HzFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesStandard: Two entries 3/4” NPT includedOne 3/4” zinc chromed steel plug and One cable gland - 3/4” NPT Brass for non-armoured cable, diameter 8-10.5mm

Terminal block (plug in terminal block)Up to 10mm² (rigid wire), 6mm² (fl exible wire)Terminals supplied L, N, PELooping possibleLamps (order separately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lampOther optionsStainless steel shock proof kit 304LEnclosure: Offshore and other colours

GUV Range 124 PA NPT Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 30: Catalog Thomas Betts

Approvals / Characteristics Features

30

XFP RangeTubular fl uorescent fi tting with

automatic switch off

Approved to: EN60079-0, 60079-1, 60079-7, EN61241-0, 61241-1 EC TYPE Examination Certificate:INERIS 11 ATEX 0052XEx II 2 GEx de IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (All Polycarbonate tubes)Ex de IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass tubes)Ex de IIB T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass versions - XFP140V, XFP165V, XFP240V and XFP265V)Ex II 2 DEx tD IIIC A21 IP6x T80°CGlow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +55ºC

Certifi cation & Standards

• Manufactured from marine grade aluminium• All components mounted on slide gear tray for easy installation and maintenance• Maintenance in hazardous area is quick and easy with isolation switch for safe maintenance• Standard components used inside body allowing reduced maintenance costs• Available in Glass for paint shop and other spray applications for easy cleaning• Including accessories, cable gland & fixing brackets

Thomas & Betts • www.tnb-hazardous.com

Page 31: Catalog Thomas Betts

EXL Conduit 140

Ex lighting - XFP Range

Technical Specifi cations

31

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 162

EnclosureEnd caps according to standard: EN1706:EN AC-AISi12(Fe) DF or EN AC-AISi10Mg(a) DF marine grade aluminiumYellow polyurethane paint RAL 1003FixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesStandard electronic ballast:AC/DC 220V-240V, 50-60HzFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesStandard: M20 cable entry includedOne cable gland - Nickel Plated Brass ISO M20 for non-armoured cable, diameter 8-13mm

Terminal block (plug in terminal block)Up to 6mm² (rigid wire), 4mm² (fl exible wire)Lamps (order separately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lampOther optionsStainless steel shock proof kit 304LEnclosure: Offshore and other colours

Wiring Nominal Dimensions (mm)

Type Configuration Rating (W) Current (A) Diffuser A B Weight (kg)

XFP120-0G000 3 Wire 1 x 18 0.15 Polycarbonate 780 565 5.5

XFP136-0G000 3 Wire 1 x PL36 0.2 Polycarbonate 1385 1170 6

XFP140-0G000 3 Wire 1 x 36 0.2 Polycarbonate 1385 1170 9

XFP155-0G000 3 Wire 1 x PL55 0.25 Polycarbonate 1690 1475 6

XFP165-0G000 3 Wire 1 x 58 0.35 Polycarbonate 1690 1475 11

XFP220-0G000 3 Wire 2 x 18 0.3 Polycarbonate 780 565 6.5

XFP236-0G000 3 Wire 2 x PL36 0.4 Polycarbonate 1385 1170 6.5

XFP240-0G000 3 Wire 2 x 36 0.4 Polycarbonate 1385 1170 10

XFP255-0G000 3 Wire 2 x PL55 0.5 Polycarbonate 1690 1475 12

XFP265-0G000 3 Wire 2 x 58 0.5 Polycarbonate 1690 1475 12

XFP120V-0G000 3 Wire 1 x 18 0.15 Glass 780 565 7

XFP136V-0G000** 3 Wire 1 x PL36 0.2 Glass 1385 1170 8

XFP140V-0G000 3 Wire 1 x 36 0.2 Glass 1385 1170 17

XFP155V-0G000** 3 Wire 1 x PL55 0.25 Glass 1690 1475 8

XFP165V-0G000 3 Wire 1 x 58 0.35 Glass 1690 1475 17

XFP220V-0G000 3 Wire 2 x 18 0.3 Glass 780 565 8.5

XFP236V-0G000** 3 Wire 2 x PL36 0.4 Glass 1385 1170 8.5

XFP240V-0G000** 3 Wire 2 x 36 0.4 Glass 1385 1170 18

XFP255V-0G000** 3 Wire 2 x PL55 0.5 Glass 1690 1475 18

XFP265V-0G000 3 Wire 2 x 58 0.5 Glass 1690 1475 20

**T5 for gas or T95ºC for dust when supply is 240V AC

GUV Range 124 PA Metric Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 32: Catalog Thomas Betts

• Manufactured from marine grade aluminium• All components mounted on the gear tray for easy installation and maintenance• Standard components used inside the body allowing reduced maintenance costs• Available in Glass for paint shop and other spray applications for easy cleaning• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

32

XEL RangeMiniature tubular fl uorescent fi tting

Approved to: EN60079-0, 60079-1, 60079-7, 60079-31EC TYPE Examination Certificate:INERIS II ATEX 0051XEx II 2 GEx d IIC T6 GbEx II 2 DEx tb IIIC T80°C Db IP66Glow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +55ºC

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 33: Catalog Thomas Betts

Ex lighting - XEL Range

Technical Specifi cations

33

EnclosureEnd caps according to standard: EN1706:EN AC-AISi12(Fe) DF or EN AC-AISi10Mg(a) DF marine grade aluminiumYellow polyurethane paint RAL 1003FixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesStandard electronic ballast: AC/DC 220-240V, 50-60HzPower factor0.9 with capacitor included in all modelsCable entriesXEL: Two entries 3/4” NPT includedOne 3/4” stopping plug and One cable gland - 3/4” NPT Brass for non-armoured cable, diameter 8-10.5mm

Terminal blockUp to 10mm² (rigid wire), 6mm² (fl exible wire)Terminals supplied for L, N, PE loopingLamps (order separately)T5 bi-pin G5 tubes, Ø 16 coolwhite 4000°KCompact fl uorescent PL lamp with G11 base (18W) or G23 (7W, 9W, 11W)Other optionsStainless steel shockproof kit 304LEnclosure: Offshore and other colours

Dimensions

Wiring Nominal Dimensions (mm)

Type Configuration Rating (W) Current (A) Diffuser A B Weight (kg)

XEL3008-0G000 3 Wire 1 x 8 0.1 Polycarbonate 780 565 5

XEL3009-0G000 3 Wire 1 x PL9 0.1 Polycarbonate 780 565 9

XEL30011-0G000 3 Wire 1 x PL11 0.1 Polycarbonate 780 565 5

XEL120-0G000 3 Wire 1 x PL18 0.1 Polycarbonate 780 565 4.5

XEL220-0G000 3 Wire 2 x PL18 0.1 Polycarbonate 780 565 5

XEL30028-0G000 3 Wire 2 x 8 0.1 Polycarbonate 780 565 5

XEL3008V-0G000 3 Wire 1 x 8 0.1 Glass 780 565 7

XEL3009V-0G000 3 Wire 1 x PL9 0.1 Glass 780 565 9

XEL30011V-0G000 3 Wire 1 x PL11 0.1 Glass 780 565 7

XEL120V-0G000 3 Wire 1 x PL18 0.1 Glass 780 565 6.5

XEL220V-0G000 3 Wire 2 x PL18 0.1 Glass 780 565 7

XEL30028V-0G000 3 Wire 2 x 8 0.1 Glass 780 565 7

EXL Conduit 140

Related Products

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 162 GUV Range 124 PA NPT Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 34: Catalog Thomas Betts

Approvals / Characteristics Features

34

Approved to: EN60079-0, 60079-1, 60079-7, EN61241-0, 61241-1EC TYPE Examination Certificate:INERIS II ATEX 0052XEx II 2 GEx de IIC T6 GbEx II 2 DEx tD A21 IP66 T80ºCGlow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +55ºC

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

• Manufactured from marine grade aluminium• All components mounted on the gear tray for easy installation and maintenance• Standard components used inside the body allowing reduced maintenance costs• Available in Glass for paint shop and other spray applications for easy cleaning• Maintenance in hazardous area - quick and easy isolation switch for safe maintenance in hazardous area• Including accessories, cable gland & fixing brackets

XEP RangeMiniature tubular fl uorescent fi tting

with automatic switch off

Page 35: Catalog Thomas Betts

Ex lighting - XEP Range

Technical Specifi cations

35

EnclosureEnd caps according to standard: EN1706:EN AC-AlSi12(Fe) DF or EN AC-AlSi10Mg(a) DF marine grade aluminiumYellow polyurethane paint RAL 1003FixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesStandard electronic ballast: AC/DC 220-240V, 50-60HzPower factorSuperior to 0.98Cable entriesOne M20 cable entry includedOne cable gland - Nickel Plated Brass ISO M20 for non-armoured cable, diameter 8-13mm

Terminal blockUp to 6mm² (rigid wire), 4mm² (fl exible wire)Terminals supplied for L, N, PELamps (oder separately)T5 bi-pin G5 tubes, Ø 16 coolwhite 4000°KCompact fl uorescent PL lamp with G11 base (18W) or G23 (7W, 9W, 11W)Other optionsStainless steel shockproof kit 304L (factory fi tted)Enclosure: Offshore and other colours

Dimensions

Wiring Nominal Dimensions (mm)

Type Configuration Rating (W) Current (A) Diffuser A B Weight (kg)

XEP3008-0G000 3 Wire 1 x 8 0.1 Polycarbonate 780 565 5

XEP3009-0G000 3 Wire 1 x PL9 0.1 Polycarbonate 780 565 5

XEP30011-0G000 3 Wire 1 x PL11 0.1 Polycarbonate 780 565 5

XEP120-0G000 3 Wire 1 x PL18 0.1 Polycarbonate 780 565 4.5

XEP220-0G000 3 Wire 2 x PL18 0.1 Polycarbonate 780 565 5

XEP30028-0G000 3 Wire 2 x 8 0.1 Polycarbonate 780 565 5

XEP3008V-0G000 3 Wire 1 x 8 0.1 Glass 780 565 7

XEP3009V-0G000 3 Wire 1 x PL9 0.1 Glass 780 565 7

XEP30011V-0G000 3 Wire 1 x PL11 0.1 Glass 780 565 7

XEP120V-0G000 3 Wire 1 x PL18 0.1 Glass 780 565 6.5

XEP220V-0G000 3 Wire 2 x PL18 0.1 Glass 780 565 7

XEP30028V-0G000 3 Wire 2 x 8 0.1 Glass 780 565 7

EXL Conduit 140

Related Products

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 162 GUV Range 124 PA Metric Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 36: Catalog Thomas Betts

• Compact, lightweight and robust

• Ex e integral juction box: easy connection

• Excellent photometric properties, wide or narrow beam

• Internationally recognised

• Supplied with lamp installed and cable gland

Approvals / Characteristics Features

36

XF RangeFloodlight fi ttings

Approved to: EN60079-0, 60079-1, 60079-7EC TYPE Examination Certificate:LCIE 00 ATEX 6019X / IECEx LCI 11-0062XEx II 2 GEx de IIB T1 to T5 Gb for ≤ -20ºC to ≤ +60ºCdepending on model

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 37: Catalog Thomas Betts

EXL Conduit 140

Ex lighting - XF Range

Nominal Temperature Class

Type Mounting Rating (W) Current (A) Version -20ºC to +40ºC -20ºC to +60ºC Weight (kg)

XSF70P-00000 Flat 1 x 70 0.4 HP Sodium T4 T3 17

XSF70G-00000 Pole 1 x 70 0.4 HP Sodium T4 T3 17

XSF150P-00000 Flat 1 x 150 0.8 HP Sodium T4 T3 17

XSF150G-00000 Pole 1 x 150 0.8 HP Sodium T4 T3 17

XSF250P-00000 Flat 1 x 250 1.3 HP Sodium T3 T3 18

XSF250G-00000 Pole 1 x 250 1.3 HP Sodium T3 T3 18

XSF400P-00000 Flat 1 x 400 2.1 HP Sodium T3 T2 20

XSF400G-00000 Pole 1 x 400 2.1 HP Sodium T3 T2 20

XQF250P-00000 Flat 1 x 250 1.3 Metal Halide T3 T2 20

XQF250G-00000 Pole 1 x 250 1.3 Metal Halide T3 T3 18

XQF400P-00000 Flat 1 x 400 2.1 Metal Halide T3 T3 18

XQF400G-00000 Pole 1 x 400 2.1 Metal Halide T3 T2 20

XEF110P-00000 Flat 2 x 55 9.2 Halogen (12V) T5 T5 13

XEF110G-00000 Pole 2 x 55 9.2 Halogen (12V) T5 T5 13

XEF140P-00000 Flat 2 x 70 5.8 Halogen (24V) T5 T5 13

XEF140G-00000 Pole 2 x 70 5.8 Halogen (24V) T5 T5 13

Technical Specifi cations

37

Related Products

EnclosureMarine grade aluminium alloy type according to EN1706:EN AC-AlSi7 Mg 0,6 T6Cataphoretically treated - yellow polyester paint RAL 1003 12mm toughened glass

Rated voltagesVersion HPS/metal halide:Standard: 230V 50Hz ferromagnetic ballast,with capacitorFor other voltages contact SalesPower factor0.85 for version with compensated ballast (Sodium HP and metal halide)Cable entriesStandard: Two entries M20 included One Nickel Plated Brass M20 cable gland withfi xing fl ange for non-armoured cable, Ø 8-13mm and One M20 Nickel Brass plug

Terminal blockUp to 6mm² (rigid wire), 4mm² (fl exible wire)Lamps (Installed)Polished aluminium refl ectorStandard:wide beamFixingStandard:galvanised steel fl at mounting bracket, yellow polyester paint RAL1003Pole mounted: Ø 40 to 60mm

Dimensions

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 164 GUV Range 124

Standard Flat Pole Mounting

PA Metric Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 38: Catalog Thomas Betts

• Lightweight and robust for easy installation

• Static or flashing versions available for use in a

variety of applications

• Choice of 5 colours

• 2 or 3 light versions available for traffic signals

• Supplied with single cable gland and lamps installed

Approvals / Characteristics Features

38

XFB / XFL RangeWarning lights and beacons

Approved to: EN60079-0, 60079-15, 60079-31EC TYPE Examination Certificate:Ex II 3 G / DEx nA IIC T5 GcEx tc IIIC T100ºC DC IP6X for ≤ -20ºC to ≤ +60ºC

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 39: Catalog Thomas Betts

Type Rating (W) Lamp Version Weight (kg)

XFB30-00000 1 x 28 E27 Halogen 3.5

XFB70-00000 1 x 8 E27 LED 3.5

XFL30P-00000 30 Joules Picots Xenon flash 4

Ex lighting - XFB / XFL Range

Technical Specifi cations

39

EnclosureMarine grade aluminium alloy type EN1706 AC-43100KF-AlSi 10MgYellow polyurethane paint RAL1003Aluminium refl ectorTemperatureAmbient temperature: -20°C to +60°C

Rated voltagesHalogen AC: 230V, 50-60HzLED AC: 100-240V, 50-60HzXenon Flash AC: 230V, 50-60HzCable entriesStandard: Two entries M20 includedOne plug and one cable gland - Nickel ISO M20 for non-armoured cable, diameter 8-13mmTerminal blockUp to 6mm2

Terminals supplied for L, N,P, E.

Lamps (supplied)For xenon fl ash versionsFlashing rate: 45 to 60 - per minuteGlobe3mm thick polycarbonateStandard: RedOption: Green, Orange / Yellow, Blue, Transparent

Dimensions

Related Products

Spares & Fixings Accessories see pages 94-99

EXL Conduit 140 Stopping Plugs 164 GUV Range 124 Thread Convertors 158

Thomas & Betts • www.tnb-hazardous.com

Contact Sales for Mounting Options8

Page 40: Catalog Thomas Betts

Approvals / Characteristics Features

40

XDF RangeDrilling fl uorescent fi tting

Approved to: EN60079-0, 60079-15EC TYPE Examination Certificate:Ex II 3 G / DEx nA IIC T4 GcEx tc IIIC T135ºC Dc IP6X Temperature range: -20ºC to +60ºC

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

X

• Vibration resistant lighting system

• Plug in system for fast installation

• Designed to minimise heat build up and overheating

• Corrosion resistant ideal for marine applications

• Hazardous and safe area versions available

Page 41: Catalog Thomas Betts

Wiring Nominal

Type Configuration Rating (W) Current (A) Diffuser A B Weight (kg)

XDF140-00000 3 Wire 1 x 36 0.20 Polycarbonate 1173 1540 8.5

XDF165-00000 3 Wire 1 x 58 0.35 Polycarbonate 1474 1841 9

Ex lighting - XDF Range

Technical Specifi cations

41

EnclosureEnd caps according to standard: EN1706:EN AC-AISi12(Fe) DF or EN AC-AISi10Mg(a) DF marine grade aluminium Including offshore optionYellow polyurethane paint RAL 1003

Rated voltagesFerromagnetic ballast:230V, 50HzCable entriesStandard: Three M20 cable entriesSupplied with: One plug entry: male - 2 poles & earth - 10Amp - 250VACOne socket entry: female - 2 poles & earth -10 Amp - 250VACOne extendable cable with male plug and female socket (Helical cable) expandable to 5 metre max

Terminal block (plug in terminal block)Up to 6mm² (fl exible wire)Terminals supplied L, N, PELamps (supplied on request)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KFixing2 Brackets for beam clamp fi xing

Dimensions

Related Products

Spares & Fixings Accessories see pages 94-99

EXL Conduit 140 Stopping Plugs 164 GUV Range 124

Thomas & Betts • www.tnb-hazardous.com

264

B

A 80

145

108

145

108

11

155 220

Must be used with XD104RContact Sales for further details

Page 42: Catalog Thomas Betts

• Easy disconnector for safer maintenance out of zones • Main body constructed of a GRP for high impact strength• Polycarbonate diffuser to resist harsh environments• Automatic switch off upon opening for safe maintenance• All components mounted on hinged and removable gear tray which gives easy access for intallation and maintenance• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

42

EVS RangeFluorescent fi tting with easy disconnect

Approved to: EN60079-0, 60079-1, 60079-5, 60079-7, EN61241-1EC TYPE Examination Certificate:LCIE 11 ATEX 3065X IEC Ex LCI 11.0053XEx II 2 GEx de IIC T4 Gb for ≤ -40ºC to ≤ +60ºCEx de IIC T5 Gb for ≤ -40ºC to ≤ +35ºCEx II 2 DEx tD IIIC A21 T85ºC Db IP64Glow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +50ºC

Certifi cation & Standards

4

Thomas & Betts • www.tnb-hazardous.com

Page 43: Catalog Thomas Betts

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166

Ex lighting - EVS Range

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Current (A) A B C Weight (kg)

EVS120-0000 3 Wire Loop 1 x 18 0.09 785 432 400 5.5

EVS120-A000 5 Wire Loop 1 x 18 0.09 785 432 400 5.5

EVS120-B000 5 Wire Through 1 x 18 0.09 785 432 400 5.5

EVS140-0000 3 Wire Loop 1 x 36 0.17 1370 900 700 7.5

EVS140-A000 5 Wire Loop 1 x 36 0.17 1370 900 700 7.5

EVS140-B000 5 Wire Through 1 x 36 0.17 1370 900 700 7.5

EVS165-0000 3 Wire Loop 1 x 58 0.26 1670 900 700 9

EVS165-A000 5 Wire Loop 1 x 58 0.26 1670 900 700 9

EVS165-B000 5 Wire Through 1 x 58 0.26 1670 900 700 9

EVS220-0000 3 Wire Loop 2 x 18 0.17 785 432 400 6.5

EVS220-A000 5 Wire Loop 2 x 18 0.17 785 432 400 6.5

EVS220-B000 5 Wire Through 2 x 18 0.17 785 432 400 6.5

EVS240-0000 3 Wire Loop 2 x 36 0.33 1370 900 700 8.5

EVS240-A000 5 Wire Loop 2 x 36 0.33 1370 900 700 8.5

EVS240-B000 5 Wire Through 2 x 36 0.33 1370 900 700 8.5

EVS265-0000 3 Wire Loop 2 x 58 0.5 1670 900 700 10

EVS265-A000 5 Wire Loop 2 x 58 0.5 1670 900 700 10

EVS265-B000 5 Wire Through 2 x 58 0.5 1670 900 700 10

*EVS... C000 - 3 Wire loop & continuity plate*EVS... E000 - 5 Wire through & 2 continuity plates

Technical Specifi cations

43

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser EPDM cellular gasketsFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC 220-240V, 50-60HzDC 220-240VFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesStandard: Three M20 entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option:Nickel Brass cable gland (1 or 2 according to number of plates)

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Lamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

XB100 Range 108

Thomas & Betts • www.tnb-hazardous.com

Page 44: Catalog Thomas Betts

• Main body constructed of a GRP for high impact strength• Polycarbonate diffuser to resist harsh and corrosive environments• All components mounted on hinged and removable gear tray which gives easy access for installation and maintenenace• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

44

EVN RangeFluorescent fi tting with diffuser

Approved to: EN60079-0, 60079-15, EN61241-1EC TYPE Examination Certificate: Under new 94/9/EC self certifiedEx II 3 GEx nr IIC T4 Gb for ≤ -40ºC to ≤ +60ºCEx nr IIC T6 Gb for ≤ -40ºC to ≤ +35ºCEx II 3 DEx tD IIIC A22 T85ºC to T135ºC Db IP6xGlow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +50ºC

Certifi cation & Standards

4

Thomas & Betts • www.tnb-hazardous.com

Page 45: Catalog Thomas Betts

Ex lighting - EVN Range

Technical Specifi cations

45

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser EPDM cellular gasketFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC 220-240V, 50-60HzDC 220-240VFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option: Nickel Brass cable gland (1 or 2 according to number of plates)

Terminal blockUp to 6mm² (rigid wire), 4mm² (fl exible wire)Lamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Current (A) A B C Weight (kg)

EVN120-0000 3 Wire Loop 1 x 18 0.09 785 432 400 4.2

EVN120-A000 5 Wire Loop 1 x 18 0.17 785 432 400 4.2

EVN120-B000 5 Wire Through 1 x 18 0.17 785 432 400 4.2

EVN140-0000 3 Wire Loop 1 x 36 0.17 1370 900 700 6.5

EVN140-A000 5 Wire Loop 1 x 36 0.17 1370 900 700 6.5

EVN140-B000 5 Wire Through 1 x 36 0.17 1370 900 700 6.5

EVN165-0000 3 Wire Loop 1 x 58 0.26 1670 900 700 8

EVN165-A000 5 Wire Loop 1 x 58 0.26 1670 900 700 8

EVN165-B000 5 Wire Through 1 x 58 0.26 1670 900 700 8

EVN220-0000 3 Wire Loop 2 x 18 0.17 785 432 400 4.5

EVN220-A000 5 Wire Loop 2 x 18 0.17 785 432 400 4.5

EVN220-B000 5 Wire Through 2 x 18 0.17 785 432 400 4.5

EVN240-0000 3 Wire Loop 2 x 36 0.33 1370 900 700 6.8

EVN240-A000 5 Wire Loop 2 x 36 0.33 1370 900 700 6.8

EVN240-B000 5 Wire Through 2 x 36 0.33 1370 900 700 6.8

EVN265-0000 3 Wire Loop 2 x 58 0.5 1670 900 700 8.5

EVN265-A000 5 Wire Loop 2 x 58 0.5 1670 900 700 8.5

EVN265-B000 5 Wire Through 2 x 58 0.5 1670 900 700 8.5

*EVN... C000 - 3 Wire loop & continuity plate*EVN... E000 - 5 Wire through & 2 continuity plates

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 46: Catalog Thomas Betts

46

EVD RangeFluorescent fi tting

• Main body constructed of a GRP for high impact strength

• Polycarbonate diffuser to resist harsh and

corrosive environments

• All componets mounted on hinged and removable gear tray

which gives easy access for installation and maintenance

• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

Approved to: EN60079-0, 60079-31EC TYPE Examination Certificate: Under new 94/9/EC self certifiedLCIE II ATEX 3092XIECEx LCI 11.0064XEx II 2 DEx t IIIC T82ºC (≤ +60ºC) DbEx t IIIC T62ºC (≤ +40ºC) DbGlow wire test: 960ºC EN60598-2-22Safe operating temperature range: -40°C to +60ºC

Certifi cation & Standards

4

Thomas & Betts • www.tnb-hazardous.com

Page 47: Catalog Thomas Betts

Ex lighting - EVD Range

Technical Specifi cations

47

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuserEPDM cellular gasketFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC/DC 220-240V, 50-60HzFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries included Two M20 Nylon plugs andOne cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option: Nickel Brass cable gland (1 or 2 according to number of plates)

Terminal blockUp to 6mm² (rigid wire), 4.5mm² (fl exible wire)Terminals supplied for L1, L2, L3, N, PE (1 max 16A)Lamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Current (A) A B C Weight (kg)

EVD120-00J0 3 Wire Loop 1 x 18 0.09 785 432 400 4.2

EVD120-A0J0 5 Wire Loop 1 x 18 0.09 785 432 400 4.2

EVD120-B0J0 5 Wire Through 1 x 18 0.09 785 432 400 4.2

EVD140-00J0 3 Wire Loop 1 x 36 0.17 1370 900 700 6.5

EVD140-A0J0 5 Wire Loop 1 x 36 0.17 1370 900 700 6.5

EVD140-B0J0 5 Wire Through 1 x 36 0.17 1370 900 700 6.5

EVD165-00J0 3 Wire Loop 1 x 58 0.26 1670 900 700 8

EVD165-A0J0 5 Wire Loop 1 x 58 0.26 1670 900 700 8

EVD165-B0J0 5 Wire Through 1 x 58 0.26 1670 900 700 8

EVD220-00J0 3 Wire Loop 2 x 18 0.17 785 432 400 4.5

EVD220-A0J0 5 Wire Loop 2 x 18 0.17 785 432 400 4.5

EVD220-B0J0 5 Wire Through 2 x 18 0.17 785 432 400 4.5

EVD240-00J0 3 Wire Loop 2 x 36 0.33 1370 900 700 6.8

EVD240-A0J0 5 Wire Loop 2 x 36 0.33 1370 900 700 6.8

EVD240-B0J0 5 Wire Through 2 x 36 0.33 1370 900 700 6.8

EVD265-00J0 3 Wire Loop 2 x 58 0.5 1670 900 700 8.5

EVD265-A0J0 5 Wire Loop 2 x 58 0.5 1670 900 700 8.5

EVD265-B0J0 5 Wire Through 2 x 58 0.5 1670 900 700 8.5

*EVD... C0J0 - 3 Wire loop & continuity plate*EVD... E0J0 - 5 Wire through & 2 continuity plates

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 48: Catalog Thomas Betts

• Main body made from powder coated steel

• 6mm toughened glass making it perfect

for laboratories

• Automatic switch off upon opening

for safe maintenance

• Including accessories & cable gland

Approvals / Characteristics Features

48

ESB RangeRecessed fl uorescent fi tting

Approved to: EN60079-0, 60079-1, 60079-7EC TYPE Examination Certificate: Under 94/9/EC INERIS II ATEX 0058XEx II 2 GEx de IIC T4 Gb for ≤ -20ºC to ≤ +40ºCGlow wire test: 850°C EN60598-2-22Safe operating temperature range: -20°C to +40ºC

Certifi cation & Standards

5

Thomas & Betts • www.tnb-hazardous.com

Page 49: Catalog Thomas Betts

Ex lighting - ESB Range

Technical Specifi cations

49

Related Products

EnclosureSteel housing and body painted in white polyester powderpaint RAL 9016 6mm clear toughened glass panel (optional frosted low lumen output) Neoprene gasket

Rated voltagesStandard: electronic ballast AC/DC 220-240V, 50-60HzFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesTwo M20 cable entries includedOne M20 Nylon stopping plug and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cable

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Terminals supplied for L, N, PELamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k FixingFixing by 4 M6 threaded bolts (not supplied) joined to the main body

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Current (A) Glass A B C Weight (kg)

ESB220-0000 3 Wire 2 x 18 0.17 Toughened 753 702 105 12.5

ESB220-A000 3 Wire 2 x 18 0.17 Frosted 753 702 105 12.5

ESB240-0000 3 Wire 2 x 36 0.33 Toughened 1364 1312 105 20

ESB240-A000 3 Wire 2 x 36 0.33 Frosted 1364 1312 105 20

ESB265-0000 3 Wire 2 x 58 0.5 Toughened 1664 1612 105 25

ESB265-A000 3 Wire 2 x 58 0.5 Frosted 1664 1612 105 25

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

240

240

Page 50: Catalog Thomas Betts

Approvals / Characteristics Features

50

XFF-EM RangeEmergency tubular fl uorescent fi tting

Approved to: EN60079-0, 60079-1, 60079-31 EC TYPE Examination Certificate:INERIS 11 ATEX 0051XEx II 2 GEx d IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (All Polycarbonate tubes)Ex d IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass tubes)Ex d IIB T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass versions - XFR140EMand XFF240EM)Ex II 2 DEx tb IIIC T80°C Db IP66Glow wire test: 960ºC EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

• Manufactured from marine grade aluminium• All components mounted on the gear tray for easy installation and maintenance• Standard components used inside the body allowing reduced maintenance costs• Available in Glass for paint shop and other spray applications for easy cleaning• Battery duration 2 hours• Including accessories, cable gland & fixing brackets

Thomas & Betts • www.tnb-hazardous.com

Page 51: Catalog Thomas Betts

EXL Conduit 140

Ex Emergency lighting - XFF-EM Range

Technical Specifi cations

51

Related Products

EnclosureEnd caps and cover in marine grade aluminium alloy type EN 1706 EN AC-AlSi12(Fe) DF orEN AC-AlSi10 Mg(a) DFYellow polyurethane paint RAL 1003FixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesElectronic ballast:AC/DC 220V-240V, 50-60HzPower factorSuperior to 0.98Cable entriesStandard: Two entries 3/4” NPT includedOne 3/4” zinc chromed steel plug and One cable gland - 3/4” NPT Brass for non-armoured cable, diameter 8-10.5mmBatteryLumen output in emergency mode (1 tube lit)40% for 18W33% for 40W

Terminal block (plug in terminal block)Up to 10mm² (rigid wire), 6mm² (fl exible wire)Supplied L, N, PE terminalsSelect function: Lighting in maintained mode or lighting in non-maintained modeLamps (order seperately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lampOther optionsStainless steel shockproof kit 304LEnclosure: Offshore and other colours

Dimensions

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 162

Wiring Dimensions (mm)

Type Configuration Rating (W) Battery Diffuser A B Weight (kg)

XFR120EM-0G000 3 Wire 1 x 18 2h Polycarbonate 780 565 7.5

XFR140EM-0G000 3 Wire 1 x 36 2h Polycarbonate 1385 1170 9.5

XFF220EM-0G000 3 Wire 2 x 18 2h Polycarbonate 780 565 7.5

XFF240EM-0G000 3 Wire 2 x 36 2h Polycarbonate 1385 1170 9.5

XFR120VEM-0G000 3 Wire 1 x 18 2h Glass 780 565 9.5

XFR140VEM-0G000 3 Wire 1 x 36 2h Glass 1385 1170 9.5

XFF220VEM-0G000 3 Wire 2 x 18 2h Glass 780 565 9.5

XFF240VEM-0G000 3 Wire 2 x 36 2h Glass 1385 1170 9.5

GUV Range 124 PA NPT Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 52: Catalog Thomas Betts

Approvals / Characteristics Features

52

Approved to: EN60079-0, 60079-1, 60079-7, 60079-31, EN61241-0, 61241-1 EC TYPE Examination Certificate:INERIS 11 ATEX 0052XEx II 2 GEx de IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (All Polycarbonate tubes)Ex de IIC T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass tubes)Ex de IIB T6 Gb for ≤ -20ºC to ≤ +55ºC (Glass versions - XFP140EM and XFP240EM)Ex II 2 DEx tD IIIC A21 IP6x T80°C Glow wire test: 960ºC EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

• Manufactured from marine grade aluminium• Maintenance in hazardous area is quick and easy with isolation switch for safe maintenance• All components mounted on the gear tray for easy installation and maintenance• Standard components used inside the body allowing reduced maintenance costs• Available in Glass for paint shop and other spray applications for easy cleaning• Battery duration 2 hours• Including accessories, cable gland & fixing brackets

Thomas & Betts • www.tnb-hazardous.com

XFP-EM RangeEmergency tubular fl uorescent fi tting

with automatic switch off

Page 53: Catalog Thomas Betts

Ex Emergency lighting - XFP-EM Range

Technical Specifi cations

53

Related Products

Dimensions

EnclosureEnd caps and cover in marine grade aluminium alloy type EN1706:EN AC-AlSi12(Fe) DF orEN AC-AlSi10 Mg(a) DFYellow polyurethane paint RAL 1003FixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesStandard: electronic ballast:AC/DC 220V-240V, 50-60HzPower factorSuperior to 0.98Cable entriesStandard M20 cable entry includedOne cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableBatteryLumen output in emergency mode (1 tube lit)40% for 18W33% for 33WMonitored by one LED

Terminal block (plug in terminal block)Up to 6mm² (rigid wire), 4mm² (fl exible wire)Supplied L, N, PE terminalsSelect function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lampOther optionsStainless steel shockproof kit 304LEnclosure: Offshore and other colours

Wiring Dimensions (mm)

Type Configuration Rating (W) Battery Diffuser A B Weight (kg)

XFP120EM-0G000 3 Wire 1 x 18 2h Polycarbonate 780 565 7.5

XFP120EM-0G000 3 Wire 1 x 36 2h Polycarbonate 1385 1170 7.5

XFP120EM-0G000 3 Wire 2 x 18 2h Polycarbonate 780 565 9.5

XFP120EM-0G000 3 Wire 2 x 36 2h Polycarbonate 1385 1170 9.5

XFP120VEM-0G000 3 Wire 1 x 18 2h Glass 780 565 9.5

XFP120VEM-0G000 3 Wire 1 x 36 2h Glass 1385 1170 11

XFP120VEM-0G000 3 Wire 2 x 18 2h Glass 780 565 9.5

XFP120VEM-0G000 3 Wire 2 x 36 2h Glass 1385 1170 11

Thomas & Betts • www.tnb-hazardous.com

Spares & Fixings Accessories see pages 94-99

Stopping Plugs 162 GUV Range 124 PA Metric Gland 150 EFDC Range 126

Page 54: Catalog Thomas Betts

Approvals / Characteristics Features

54

XEL-BAES RangeSelf-contained emergency lighting fi tting

Approved to: EN60079-0, 60079-1, 60079-7, 60079-31, EN61241-0, 61241-1EC TYPE Examination Certificate:Models SI & AIINERIS II ATEX 0052XEx II 2 GEx de IIC T6 Gb Ex II 2 DEx tD A21 IP6x T80°CGlow wire test: 960ºC EN60598-2-22Safe operating temperature range: -20°C to +55ºC

Certifi cation & Standards

• Manufactured from marine grade aluminium• All components mounted on the gear tray for easy installation and maintenance• Self contained luminaires with built in automatic facility to give local indication of result, test or control monitoring• Available in Glass for paint shop and other spray applications for easy cleaning• Including accessories, cable gland & fixing brackets

Part No. B019T

Models A & AKINERIS II ATEX 0051XEx II 2 GEx d IIC T6 Gb Ex II 2 DEx tb IIIC T80ºC IP66 Db

Thomas & Betts • www.tnb-hazardous.com

Page 55: Catalog Thomas Betts

205

Ex Emergency lighting - XEL-BAES Range

Technical Specifi cations

55

EnclosureEnd caps and cover in marine grade aluminium alloy type AS10GY30. Yellow polyurethane paint RAL 1003 (other colour on request) including offshore availableStainless steel screwsRated voltages and emergency functionElectronic ballast: AC/DC 230V, 50HzPower factorSuperior to 0.98

Self test SATISafety lighting with automatic built in systems test the lamps every 7 days and the battery pack every 12 weeks. Results of the test are displayed by yellow and green diodes.

Cable entryModel SI & AI: One M20 cable entry includedOne cable gland - Nickel Plated Brass ISO M20, diameter 8-13mm for non-armoured cableModel A & AK: Two entries 3/4” NPT includedOne 3/4” stopping plug andOne cable gland - 3/4” NPT Brass, diameter 8-10.5mm for non-armoured cableBatteryXEL80: Lumen output for 1 hour = 70lm, XEL300: Lumen output for 1 hour = 280lm, XEL3001 and XEL3002: Battery 3h for all markets except France - No NFCTerminal blockModel SI & AI: Up to 6mm² (rigid wire), 4mm² (fl exible wire) Terminals supplied for L, N, PE loopingModel A & AK: Up to 10mm² (rigid wire), 6mm² (fl exible wire) Terminals supplied for L, N, PE loopingLamps (supplied fi tted)XEL 80: emergency lamp: 1 x 6W tube with G5 (70 lumen) lampholder, 2 charge lamp using LEDsXEL 300: emergency lamp: 1 x 8W tube with G5 (280 lumen) lampholder, 2 charge lamp using LEDsFixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Dimensions

Testing Type Switch Type (see diagrams)

Type Function Rating (W) Diffuser Manual Automatic Addressable Unswitched Switch Off Combined Weight (kg)

XEL3001-00000 Large area 1 x 8 Polycarbonate ● – – ● – – 5

XEL3002-00000* Large area 2 x 8 Polycarbonate ● – – ● – – 5

XEL80A-00000 Escape route 1 x 6 Polycarbonate – ● – ● – – 4.7

XEL80AK-00000 Escape route 1 x 6 Polycarbonate – ● – – ● – 4.7

XEL80AI-00000 Escape route 1 x 6 Polycarbonate – ● – – – ● 5.5

XEL80SI-0J000 Escape route 1 x 6 Polycarbonate – – ● – – ● 5.5

XEL300A-00000 Large area 1 x 8 Polycarbonate – ● – ● – – 5

XEL300AK-00000 Large area 1 x 8 Polycarbonate – ● – – ● – 5

XEL300AI-00000 Large area 1 x 8 Polycarbonate – ● – – – ● 5.5

XEL300SI-00000 Large area 1 x 8 Polycarbonate – – ● – – ● 5.5

XEL3001V-00000 Large area 1 x 8 Glass ● – – ● – – 7

XEL3002V-00000* Large area 2 x 8 Glass ● – – ● – – 7

XEL80VA-0J000 Escape route 1 x 6 Glass – ● – ● – – 6.5

XEL80VAK-00000 Escape route 1 x 6 Glass – ● – – ● – 6.5

XEL80VAI-00000 Escape route 1 x 6 Glass – ● – – – ● 7.3

XEL80VSI-0J000 Escape route 1 x 6 Glass – – ● – – ● 7.3

XEL300VA-00000 Large area 1 x 8 Glass – ● – ● – – 7

XEL300VAK-00000 Large area 1 x 8 Glass – ● – – ● – 7

XEL300VAI-00000 Large area 1 x 8 Glass – ● – – – ● 7.5

XEL300VSI-00000 Large area 1 x 8 Glass – – ● – – ● 7.5

*Permanent lighting

SI & AI A & AK265

Thomas & Betts • www.tnb-hazardous.com

Healthy Emergency or Indicator

Lamp Fault

Test inProgress

Fault

UNSWITCHED enclosureCompulsary power socketFitting has to be removedMaintenance must be done in safe area

Enclosure with battery SWITCH OFFNo power socketExternal cut-out requiredMaintenance done in hazardous area

Enclosure with COMBINED battery and supply switch offNo power socketNo external cut-outMaintenance done in hazardous area

Page 56: Catalog Thomas Betts

Approvals / Characteristics

56

EVS-EM RangeEmergency fl uorescent fi tting with easy disconnect

Features

Approved to: EN60079-0, 60079-1, 60079-5, 60079-7, EN61241-1EC TYPE Examination Certificate:LCIE 11 ATEX 3065X IEC Ex LCI 11.0053XEx II 2 GEx de IIC T4 Gb for ≤ -40ºC to ≤ +60ºCEx de IIC T5 Gb for ≤ -40ºC to ≤ +35ºCEx II 2 DEx tD IIIC A21 T85ºC Db IP64Glow wire test: 960ºC EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

• Easy disconnector for safer maintenance out of zones• Main body constructed of a GRP for high impact strength• Battery duration 2 hours• All componets mounted on hinged and removable gear tray which gives easy access for installation and maintenance• Automatic switch off upon opening for safe maintenance• Including accessories, cable gland & fixing brackets

4

Thomas & Betts • www.tnb-hazardous.com

Page 57: Catalog Thomas Betts

Ex Emergency lighting - EVS-EM Range

Technical Specifi cations

57

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser (protective coating optional) EPDM cellular gasketsFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cad 7.2V 4Ah battery in fl ameproof case(Auto cut out of defective light)Lumen output in emergency mode (1 tube lit): 40% at 18W, 33% at 36WBattery duration: 18W = 2 hours, 36W = 2hoursMonitored by one LEDPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option: Nickel Brass cable gland (1 or 2 according to number of plates)

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Select function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVS120EM-0000 3 Wire Loop 1 x 18 2h 0.09 785 432 400 7.5

EVS120EM-A000 5 Wire Loop 1 x 18 2h 0.09 785 432 400 7.5

EVS120EM-B000 5 Wire Through 1 x 18 2h 0.09 785 432 400 7.5

EVS140EM-0000 3 Wire Loop 1 x 36 2h 0.17 1370 900 700 9.5

EVS140EM-A000 5 Wire Loop 1 x 36 2h 0.17 1370 900 700 9.5

EVS140EM-B000 5 Wire Through 1 x 36 2h 0.17 1370 900 700 9.5

EVS220EM-0000 3 Wire Loop 2 x 18 2h 0.17 785 432 400 8.5

EVS220EM-A000 5 Wire Loop 2 x 18 2h 0.17 785 432 400 8.5

EVS220EM-B000 5 Wire Through 2 x 18 2h 0.17 785 432 400 8.5

EVS240EM-0000 3 Wire Loop 2 x 36 2h 0.33 1370 900 700 10.5

EVS240EM-A000 5 Wire Loop 2 x 36 2h 0.33 1370 900 700 10.5

EVS240EM-B000 5 Wire Through 2 x 36 2h 0.33 1370 900 700 10.5

*EVS... EM-C000 - 3 Wire loop & continuity plate*EVS... EM-E000 - 5 Wire through & 2 continuity plates

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 58: Catalog Thomas Betts

Approvals / Characteristics

58

EVS-EMA RangeEmergency fl uorescent fi tting with automatic test

Features

Approved to: EN60079-0, 60079-1, 60079-5, 60079-7, EN61241-1EC TYPE Examination Certificate:LCIE 11 ATEX 3065X IEC Ex LCI 11.0053XEx II 2 GEx de IIC T4 Gb for ≤ -40ºC to ≤ +60ºCEx de IIC T5 Gb for ≤ -40ºC to ≤ +35ºCEx II 2 DEx tD IIIC A21 T85ºC Db IP64Glow wire test: 960°C EN605988-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

• Main body constructed of a GRP for high impact strength• Battery duration 3 hours• Automatic testing for preventitive maintenance• Clear LED for visual inspection• Polycarbonate diffuser to resist harsh and corrosive environments• All componets mounted on hinged and removable gear tray• Automatic switch off upon opening for safe maintenance• Including accessories, cable gland & fixing brackets

4

Thomas & Betts • www.tnb-hazardous.com

Page 59: Catalog Thomas Betts

Ex Emergency lighting - EVS-EMA Range

Technical Specifi cations

59

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuserEPDM cellular gasketsPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC/DC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cad 6V 4Ah for 18W / Ni-Cad 6V 7Ah for 36W battery in fl ameproof case(Auto cut out of defective light)Lumen output in emergency mode (1 tube lit): 40%at 18W, 33% at 36WBattery duration: 3h max 36WPreventive maintenance - Self test- Battery charge - daily- Emergency lamp during 1min - weekly- Battery charge capacity during 1hr - quaterly- Clean system test displayBattery charge monitored by 2 LED

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Lamps (order separately)Command must be supplied with switch on lineTube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVS120EMA-A000 5 Wire Loop 1 x 18 3h 0.09 785 432 400 7.5

EVS140EMA-A000 5 Wire Loop 1 x 36 3h 0.17 1370 900 700 9.5

EVS140EMA-B000 5 Wire Through 1 x 36 3h 0.17 1370 900 700 9.5

EVS220EMA-A000 5 Wire Loop 2 x 18 3h 0.17 785 432 400 8.5

EVS240EMA-A000 5 Wire Loop 2 x 36 3h 0.33 1370 900 700 10.5

EVS240EMA-B000 5 Wire Through 2 x 36 3h 0.33 1370 900 700 10.5

Healthy(test OK)

Emergency or Indicator

Lamp Fault(must bereplaced)

Test inProgress

(waiting endof test)

Fault(replacebattery)

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 60: Catalog Thomas Betts

60

EVN-EM RangeEmergency fl uorescent fi tting

• Main body constructed of a GRP for high impact strength

• Battery duration 2 hours

• All components mounted on hinged and removable

gear tray which gives easy access for installation

and maintenance

• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

Approved to: EN60079-0, 60079-15, 61241-1EC TYPE Examination Certificate:Ex II 3 GEx nr IIC T4 Gb for ≤ -40ºC to ≤ +60ºCEx nr IIC T6 Gb for ≤ -40ºC to ≤ +35ºCEx II 3 DEx td IIIC A22 T85ºC to T135ºC Db IP6xGlow wire test: 960°C EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

4

Thomas & Betts • www.tnb-hazardous.com

Page 61: Catalog Thomas Betts

Ex Emergency lighting - EVN-EM Range

Technical Specifi cations

61

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuserFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC/DC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cd 7.2V 4Ah batteryAuto cut-off for defective lightLumen output in emergency mode (1 tube lit)40% at 18W, 33% at 36WMonitored by one LEDPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor non-armoured cable - continuity plate option: Nickel Brass cable gland (1 or 2 according to number of plates)

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Select function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVN120EM-0000 3 Wire Loop 1 x 18 2h 0.09 785 432 400 6.5

EVN120EM-A000 5 Wire Loop 1 x 18 2h 0.09 785 432 400 6.5

EVN120EM-B000 5 Wire Through 1 x 18 2h 0.09 785 432 400 6.5

EVN140EM-0000 3 Wire Loop 1 x 36 2h 0.17 1370 900 700 8.5

EVN140EM-A000 5 Wire Loop 1 x 36 2h 0.17 1370 900 700 8.5

EVN140EM-B000 5 Wire Through 1 x 36 2h 0.17 1370 900 700 8.5

EVN220EM-0000 3 Wire Loop 2 x 18 2h 0.17 785 432 400 7.5

EVN220EM-A000 5 Wire Loop 2 x 18 2h 0.17 785 432 400 7.5

EVN220EM-B000 5 Wire Through 2 x 18 2h 0.17 785 432 400 7.5

EVN240EM-0000 3 Wire Loop 2 x 36 2h 0.33 1370 900 700 10.5

EVN240EM-A000 5 Wire Loop 2 x 36 2h 0.33 1370 900 700 10.5

EVN240EM-B000 5 Wire Through 2 x 36 2h 0.33 1370 900 700 10.5

*EVN... EM-C000 - 3 Wire loop & continuity plate*EVN... EM-E000 - 5 Wire through & 2 continuity plates

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 62: Catalog Thomas Betts

• Main body constructed of a GRP for high impact strength• Polycarbonate diffuser to resist harsh and corrosive environments• Battery duration 3 hours• Automatic testing for preventive maintenance• Clear LED for easy visual inspection• Including accessories, cable gland & fixing brackets

62

EVN-EMA RangeEmergency fl uorescent fi tting with automatic test

Approvals / Characteristics Features

Approved to: EN60079-0, 60079-15, EN61241-1EC TYPE Examination Certificate: Under new 94/9/EC self certifiedEx II 3 GEx nr IIC T4 Gb for ≤ -40ºC to ≤ +60ºCEx nr IIC T6 Gb for ≤ -40ºC to ≤ +35ºCEx II 3 DEx td IIIC A22 T85ºC to T135ºC Db IP6xGlow wire test: 960°C EN605988-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

4

Thomas & Betts • www.tnb-hazardous.com

Page 63: Catalog Thomas Betts

Ex Emergency lighting - EVN-EMA Range

Technical Specifi cations

63

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser (protective coating optional) EPDM cellular gasketPower factorSuperior to 0.98Cable entriesStandard: Three M20 entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: single tube electronic ballast AC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cd 6V 4Ah for 18W /Ni-Cd 6V 7Ah for 36W batteryLumen level in emergency mode (1 tube lit): 40%in 18W, 33% in 36WBattery duration in emergency mode:3 hoursPreventive maintenance - Self test- Battery charge - daily- Emergency lamp during 1min - weekly- Battery charge capacity during 1hr - quaterly- Clean system test displayBattery charge monitored by 2 LED

Terminal blockUp to 6mm² (rigid wire), 4.5mm² (fl exible wire)Separate switch from lineLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVN120EMA-A000 5 Wire Loop 1 x 18 3h 0.09 785 170 432 6.5

EVN140EMA-A000 5 Wire Loop 1 x 36 3h 0.17 1370 170 900 8.5

EVN140EMA-B000 5 Wire Through 1 x 36 3h 0.17 1370 170 900 8.5

EVN220EMA-A000 5 Wire Loop 2 x 18 3h 0.17 785 170 432 7.5

EVN240EMA-A000 5 Wire Loop 2 x 36 3h 0.33 1370 170 900 10.5

EVN240EMA-B000 5 Wire Through 2 x 36 3h 0.33 1370 170 900 10.5

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Healthy(test OK)

Emergency or Indicator

Lamp Fault(must bereplaced)

Test inProgress

(waiting endof test)

Fault(replacebattery)

Page 64: Catalog Thomas Betts

64

EVD-EM RangeEmergency fl uorescent fi tting

Approvals / Characteristics Features

Approved to: EN60079-0, 60079-31EC TYPE Examination Certificate: Under new 94/9/EC self certifiedLCIE II ATEX 3092XIECEx LCI 11.0064XEx t IIIC T82ºC (≤ +60ºC) DbEx t IIIC T62ºC (≤ +40ºC) DbGlow wire test: 960°C EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

• Main body constructed of a GRP for high impact strength• Polycarbonate diffuser to resist harsh and corrosive environments• All componets mounted on hinged and removable gear tray which gives easy access for installation and maintenance• Battery duration 2 hours• Including accessories, cable gland & fixing brackets

4

Thomas & Betts • www.tnb-hazardous.com

Page 65: Catalog Thomas Betts

Ex Emergency lighting - EVD-EM Range

Technical Specifi cations

65

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser (protective coating optional) EPDM cellular gasketFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: dual tube electronic ballast AC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cd 7.2V 4Ah batteryLumin level in emergency mode (1 tube lit): 40%at 18W, 33% at 36WBattery duration in emenrgency mode: 2 hoursBattery charge monitored by one LEDPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option: Nickel Brass cable gland (1 or 2 ccording to number of plates)

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Terminals supplied for L1, L2, L3, N, PE (1 max 16A)Select function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVD120EM-00J0 3 Wire Loop 1 x 18 2h 0.09 785 432 400 6.5

EVD120EM-A0J0 5 Wire Loop 1 x 18 2h 0.09 785 432 400 6.5

EVD120EM-B0J0 5 Wire Through 1 x 18 2h 0.09 785 432 400 6.5

EVD140EM-00J0 3 Wire Loop 1 x 36 2h 0.17 1370 900 700 8.5

EVD140EM-A0J0 5 Wire Loop 1 x 36 2h 0.17 1370 900 700 8.5

EVD140EM-B0J0 5 Wire Through 1 x 36 2h 0.17 1370 900 700 8.5

EVD220EM-00J0 3 Wire Loop 2 x 18 2h 0.17 785 432 400 7.5

EVD220EM-A0J0 5 Wire Loop 2 x 18 2h 0.17 785 432 400 7.5

EVD220EM-B0J0 5 Wire Through 2 x 18 2h 0.17 785 432 400 7.5

EVD240EM-00J0 3 Wire Loop 2 x 36 2h 0.33 1370 900 700 10.5

EVD240EM-A0J0 5 Wire Loop 2 x 36 2h 0.33 1370 900 700 10.5

EVD240EM-B0J0 5 Wire Through 2 x 36 2h 0.33 1370 900 700 10.5

*EVD... EM-C0J0 - 3 Wire loop & continuity plate*EVD... EM-E0J0 - 5 Wire through & 2 continuity plates

Thomas & Betts • www.tnb-hazardous.com

Spares & Fixings Accessories see pages 94-99

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 66: Catalog Thomas Betts

• Main body constructed of a GRP for high impact strength• Polycarbonate diffuser to resist harsh and corrosive environments• Battery duration 3 hours• All componets mounted on hinged and removable gear tray • Automatic testing for preventive maintenance• Clear LED for easy visual inspection• Including accessories, cable gland & fixing brackets

66

EVD-EMA RangeEmergency fl uorescent fi tting with automatic test

Approvals / Characteristics Features

Approved to: EN60079-0, 60079-31EC TYPE Examination Certificate: Under new 94/9/EC self certifiedLCIE II ATEX 3092XIECEx LCI 11.0064XEx t IIIC T82ºC (≤ +60ºC) DbEx t IIIC T62ºC (≤ +40ºC) DbGlow wire test: 960°C EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

4

Thomas & Betts • www.tnb-hazardous.com

Page 67: Catalog Thomas Betts

Ex Emergency lighting - EVD-EMA Range

Technical Specifi cations

67

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser (protective coating optional) EPDM cellular gasketPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mmFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard: electronic ballast AC 220-240V, 50-60HzFor other voltages contact SalesBattery: Ni-Cd batteryLumin level in emergency mode (1 tube lit): 40%at 18W, 33% at 36WBattery duration: 3h max 36WPreventive maintenance - Self test- Battery charge - daily- Emergency lamp during 1min - weekly- Battery charge capacity during 1hr - quaterly- Clean system test displayBattery charge monitored by 2 LED

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Terminals supplied for L1, L2, L3, N, PE (1 max 16A)Through wire 16 Amp maxCommand must be supplied with switch on lineLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

170

137

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVD120EMA-A000 5 Wire Loop 1 x 18 3h 0.09 785 432 400 6.5

EVD140EMA-A000 5 Wire Loop 1 x 36 3h 0.17 1370 900 700 8.5

EVD140EMA-B000 5 Wire Through 1 x 36 3h 0.17 1370 900 700 8.5

EVD220EMA-A000 5 Wire Loop 2 x 18 3h 0.17 785 432 400 7.5

EVD240EMA-A000 5 Wire Loop 2 x 36 3h 0.33 1370 900 700 10.5

EVD240EMA-B000 5 Wire Through 2 x 36 3h 0.33 1370 900 700 10.5

Healthy(test OK)

Emergency or Indicator

Lamp Fault(must bereplaced)

Test inProgress

(waiting endof test)

Fault(replacebattery)

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 68: Catalog Thomas Betts

• Main body made from powder coated steel• 6mm toughened glass making it perfect for laboratories• Automatic switch off upon opening for safe maintenance• Battery duration 2 hours• Including accessories & cable gland

Approvals / Characteristics Features

68

ESB-EM RangeRecessed emergency fl uorescent fi tting

Approved to: EN60079-0, 60079-1, 60079-7EC TYPE Examination Certificate: Under 94/9/EC INERIS II ATEX 0058XEx II 2 GEx de IIC T4 Gb for ≤ -40ºC to ≤ +60ºCGlow wire test: 850°C EN60598-2-22Safe operating temperature range: -10°C to +40ºC

Certifi cation & Standards

5

Thomas & Betts • www.tnb-hazardous.com

Page 69: Catalog Thomas Betts

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) Glass A B C Weight (kg)

ESB240EM-0000 3 Wire 2 x 36 2h 0.33 Toughened 1364 1312 105 22

ESB240EM-A000 3 Wire 2 x 36 2h 0.33 Frosted 1364 1312 105 22

Ex Emergency lighting - ESB-EM Range

Technical Specifi cations

69

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

EnclosureSteel housing and body painted in white polyester powderpaint RAL 9016 6mm clear toughened glass panel (optional frosted low lumen output) Neoprene gasket

Rated voltagesConcealed white painted Standard: electronic ballast:AC/DC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cd 6V 7Ah battery in fl ameproof caseLumen level in emergency mode (1 tube lit): 33% Emergency load duration: 2 hoursPower factorSuperior to 0.98Cable entriesStandard: Two M20 cable entries includedOne M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Select function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k FixingFixing by 4 M6 threaded bolts (not supplied) joined to the main body

240

240

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 70: Catalog Thomas Betts

2670

Thomas & Betts • www.tnb-hazardous.com

Industrial Lighting

Page 71: Catalog Thomas Betts

Industrial Lighting

71

Thomas & Betts • www.tnb-hazardous.com

Page 72: Catalog Thomas Betts

72

FF RangeWeatherproof tubular fl uorescent fi tting

Approvals / Characteristics Features

• Ingress protection IP66 ideal for wash down areas

• All componets mounted on a removable gear tray which

gives easy access for installation and maintenance

• Including accessories, cable gland & fixing brackets

Thomas & Betts • www.tnb-hazardous.com

Page 73: Catalog Thomas Betts

Industrial Lighting - FF Range

Technical Specifi cations

73

Related Products

EnclosureReinforced black polycarbonate end capsLEXAN 2034 UV protected extruded polycarbonate tube, thickness 2.5mmTemperatureAmbient temperature: -20°C to +50°CFixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesElectronic ballast: AC/DC 220-240V, 50-60HzPower factorSuperior to 0.98Cable entriesStandard: Two M20 entries includedOne plug and one cable gland - ISO M20 Nylon, diameter 8-13mm

Terminal block (plug in terminal block)Up to 10mm2 (rigid wire), 6mm2 (fl exible wire)Standard: terminals supplied for L, N, PE, looping possibleLamps (order separately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lamp

Dimensions

Spares & Fixings Accessories see pages 94-99

Nominal Dimensions (mm)

Type Diffuser Rating (W) Current (A) A B Weight (kg)

FR120-0G000 Polycarbonate 1 x 18 0.15 780 565 4

FR136-0G000 Polycarbonate 2 x PL36 0.2 1385 1170 4.5

FR140-0G000 Polycarbonate 1 x 36 0.2 1385 1170 7

FR155-0G000 Polycarbonate 1 x PL55 0.35 1690 1475 4.5

FR165-0G000 Polycarbonate 1 x 58 0.35 1690 1475 8

FF220-0G000 Polycarbonate 2 x 18 0.3 780 565 4.5

FF236-0G000 Polycarbonate 2 x PL36 0.4 1385 1170 5

FF240-0G000 Polycarbonate 2 x 36 0.4 1385 1170 7

FF255-0G000 Polycarbonate 2 x PL55 0.7 1690 1475 5

FF265-0G000 Polycarbonate 2 x 58 0.7 1690 1475 9

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 74: Catalog Thomas Betts

74

EL RangeWeatherproof miniature tubular fl uorescent fi tting

Approvals / Characteristics Features

• Ingress protection IP66 ideal for wash down areas

• All componets mounted on a removable gear tray which

gives easy access for installation and maintenance

• Small and compact for confined spaces

• Including accessories, cable gland & fixing brackets

Thomas & Betts • www.tnb-hazardous.com

Page 75: Catalog Thomas Betts

Industrial Lighting - EL Range

Technical Specifi cations

75

Related Products

EnclosureReinforced black polycarbonate end capsLEXAN 2034 UV protected extruded polycarbonate tube, thickness 2.5mmNeoprene gasketTemperatureAmbient temperature: -20°C to +50°CFixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Rated voltagesStandard: Electronic ballast: AC/DC 220 to 240VPower factorSuperior to 0.98Standard: Two M20 entries includedOne plug and one cable gland - ISO M20 Nylon, diameter 8-13mm

Terminal block (plug in terminal block)Up to 10mm2 (rigid wire), 6mm2 (fl exible wire)Standard: terminals supplied for L, N, PE, looping possibleLamps (order separately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lampLamp with G11 base (18W)or G23 (7W, 9W, 11W)

Dimensions

Spares & Fixings Accessories see pages 94-99

Nominal Dimensions (mm)

Type Diffuser Rating (W) Current (A) A B Weight (kg)

EL3008-0G000 Polycarbonate 1 x 8 0.1 780 565 3

EL3009-0G000 Polycarbonate 1 x PL9 0.1 780 565 3

EL30011-0G000 Polycarbonate 1 x PL11 0.1 780 565 3.5

EL120-0G000 Polycarbonate 1 x PL18 0.1 780 565 3.5

EL220-0G000 Polycarbonate 2 x PL18 0.1 780 565 4

EL30028-0G000 Polycarbonate 2 x 8 0.1 780 565 3.5

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 76: Catalog Thomas Betts

76

SF / QF / EF RangeWeatherproof fl oodlight fi tting

Approvals / Characteristics Features

• Compact, lightweight and robust ideal for lighting

large areas

• Integral junction box: rapid installation

• Excellent photometric properties, wide or narrow beam

• Including accessories, cable gland & lamps installed

Thomas & Betts • www.tnb-hazardous.com

Page 77: Catalog Thomas Betts

Industrial Lighting - SF / QF / EF Range

Technical Specifi cations

77

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

Standard Flat Pole Mounting

Nominal

Type Rating (W) Current (A) Fixing Weight (kg)

SF70P-00000 1 x 70 HP Sodium 0.4 Flat 17

SF70G-00000 1 x 70 HP Sodium 0.4 Pole 17

SF150P-00000 1 x 150 HP Sodium 0.8 Flat 17

SF150G-00000 1 x 150 HP Sodium 0.8 Pole 17

SF250P-00000 1 x 250 HP Sodium 1.3 Flat 18

SF250G-00000 1 x 250 HP Sodium 1.3 Pole 18

SF400P-00000 1 x 400 HP Sodium 2.1 Flat 20

SF400G-00000 1 x 400 HP Sodium 2.1 Pole 20

QF250P-00000 1 x 250 Metal Halide 1.3 Flat 18

QF250G-00000 1 x 250 Metal Halide 1.3 Pole 18

QF400P-00000 1 x 400 Metal Halide 2.1 Flat 20

QF400G-00000 1 x 400 Metal Halide 2.1 Pole 20

EF110P-00000 2 x 55 Halogen 9.2 Flat 13

EF110G-00000 2 x 55 Halogen 9.2 Pole 13

EF140P-00000 2 x 55 Halogen 5.8 Flat 13

EF140G-00000 2 x 55 Halogen 5.8 Pole 13

EnclosureMarine grade aluminium alloy type according to EN1706:EN AC-AlSi7 Mg 0,6 T6Cataphoretically treated - yellow polyester paint RAL 1003 12mm toughened glassStainless steel screwsTemperatureAmbient temperature: -20°C to +60°C

Rated voltagesStandard: 230V 50Hz ferromagnetic ballast,with capacitorFor other voltages contact SalesPower factor0.85 for version with compensated ballast (Sodium HP and metal halide)Cable entriesStandard: Two M20 entries includedOne M20 nickel chromed brass plug andOne cable gland - Nickel Plated Brass ISO M20 for non-armoured cable, diameter 8-13mm

Terminal blockUp to 6mm² (rigid wire), 4mm² (fl exible wire)Lamps (Installed)Polished aluminium refl ectorStandard:wide beamFixingStandard:galvanised steel fl at mounting bracket, yellow polyester paint RAL1003Pole mounted: Ø 40 to 60mm

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 78: Catalog Thomas Betts

• Double central locking: for easy installation

and ingress protection

• Including accessories, cable gland & fixing brackets

78

EVT RangeWeatherproof fl uorescent fi tting with diffuser

Approvals / Characteristics Features

Thomas & Betts • www.tnb-hazardous.com

Page 79: Catalog Thomas Betts

Industrial Lighting - EVT Range

Technical Specifi cations

79

Related Products

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuser (protective coating optional) TemperatureAmbient temperature: -20ºC to +50ºCFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesStandard electronic ballast: AC/DC 220-240V, 50-60HzPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plug andOne cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option:Nickel Brass cable gland (1 or 2 according to number of plates)

Terminal blockUp to 6mm² (rigid wire), 4.5mm² (fl exible wire)Standard: Terminals supplied for L, N, PE,looping possibleLamps (order separately)T8 bi-pin G13 tube, Ø 26 - cool white 4000°K

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Current (A) A B C Weight (kg)

EVT120-00J0 3 Wire Loop 1 x 18 0.09 785 170 432 4.2

EVT120-A0J0 5 Wire Loop 1 x 18 0.09 785 170 432 4.2

EVT120-B0J0 5 Wire Through 1 x 18 0.09 785 170 432 4.2

EVT140-00J0 3 Wire Loop 1 x 36 0.17 1370 170 900 6.5

EVT140-A0J0 5 Wire Loop 1 x 36 0.17 1370 170 900 6.5

EVT140-B0J0 5 Wire Through 1 x 36 0.17 1370 170 900 6.5

EVT165-00J0 3 Wire Loop 1 x 58 0.26 1670 170 900 8

EVT165-A0J0 5 Wire Loop 1 x 58 0.26 1670 170 900 8

EVT165-B0J0 5 Wire Through 1 x 58 0.26 1670 170 900 8

EVT220-00J0 3 Wire Loop 2 x 18 0.17 785 170 432 4.5

EVT220-A0J0 5 Wire Loop 2 x 18 0.17 785 170 432 4.5

EVT220-B0J0 5 Wire Through 2 x 18 0.17 785 170 432 4.5

EVT240-00J0 3 Wire Loop 2 x 36 0.33 1370 170 900 6.8

EVT240-A0J0 5 Wire Loop 2 x 36 0.33 1370 170 900 6.8

EVT240-B0J0 5 Wire Through 2 x 36 0.33 1370 170 900 6.8

EVT265-00J0 3 Wire Loop 2 x 58 0.5 1670 170 900 8.5

EVT265-A0J0 5 Wire Loop 2 x 58 0.5 1670 170 900 8.5

EVT265-B0J0 5 Wire Through 2 x 58 0.5 1670 170 900 8.5

*EVT... C0J0 - 3 Wire loop & continuity plate*EVT... E0J0 - 5 Wire through & 2 continuity plates

170

137

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 80: Catalog Thomas Betts

• Fitting combines photometric qualities, strength

and design

• Easy access to components

• Including accessories, cable gland & fixing brackets

Approvals / Characteristics Features

80

EST RangeWeatherproof recessed fl uorescent fi tting

5

Thomas & Betts • www.tnb-hazardous.com

Page 81: Catalog Thomas Betts

Industrial Lighting - EST Range

Technical Specifi cations

81

Related Products

EnclosureSteel housing and body painted in white polyester powder paint RAL 9016 (stainless steel 304L on request) 6mm clear toughened glass panel (optional frosted low lumen output) Neoprene gasketTemperatureOperating temperature range: -20°C to +40°C

Rated voltagesStandard: electronic ballast AC 220-240V, 50-60HzDC 220-240VFor other voltages contact SalesPower factorSuperior to 0.98Cable entriesStandard: Two M20 cable entries includedOne M20 Nylon plug andOne cable gland - ISO M20 Nylon, diameter 8-13mm

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Lamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k FixingFixing by 4 M6 threaded bolts (not supplied) joined to the main body

Dimensions

Spares & Fixings Accessories see pages 94-99

240

240

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Glass Current (A) A B C Weight (kg)

EST220-00J0 3 Wire Loop 2 x 18 Toughened 0.17 753 702 105 12.5

EST220-A0J0 3 Wire Loop 2 x 18 Frosted 0.17 753 702 105 12.5

EST240-00J0 3 Wire Loop 2 x 36 Toughened 0.33 1364 1312 105 20

EST240-A0J0 3 Wire Loop 2 x 36 Frosted 0.33 1364 1312 105 20

EST265-00J0 3 Wire Loop 2 x 58 Toughened 0.5 1664 1612 105 25

EST265-A0J0 3 Wire Loop 2 x 58 Frosted 0.5 1664 1612 105 25

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 82: Catalog Thomas Betts

• Lightweight and robust for easy installation

• Static or flashing versions available for use in a

variety of applications

• Choice of 5 colours

• 2 or 3 light versions available for traffic signals

• Including accessories, cable gland & lamps installed

Approvals / Characteristics Features

82

FB / FL RangeWeatherproof warning lights and beacons

Thomas & Betts • www.tnb-hazardous.com

Page 83: Catalog Thomas Betts

Type Rating (W) Lamp Version Weight (kg)

FB30-00000 1 x 28 E27 Halogen 3.5

FB70-00000 1 x 8 E27 LED 3.5

FL30P-00000 30 Joules Picots Xenon flash 4

Industrial Lighting - FB / FL Range

Technical Specifi cations

83

EnclosureMarine grade aluminium alloy type EN1706 AC-43100KF-AlSi 10MgYellow polyurethane paint RAL1003Aluminium refl ectorTemperatureAmbient temperature: -20°C to +60°C

Rated voltagesHalogen AC: 230V, 50-60HzLED AC: 100-240V, 50-60HzXenon Flash AC: 230V, 50-60HzCable entriesStandard: Two entries M20 includedOne plug and one cable gland - Nickel ISO M20 for non-armoured cable, diameter 8-13mmTerminal blockUp to 6mm2

Terminals supplied for L, N, P, E

Lamps (supplied)For xenon fl ash versionsFlashing rate: 45 to 60 - per minuteGlobe3mm thick polycarbonateStandard: RedOption: Green, Orange / Yellow, Blue, Transparent

Dimensions

Thomas & Betts • www.tnb-hazardous.com

Contact Sales for Mounting Options8

Related Products

Spares & Fixings Accessories see pages 94-99

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 84: Catalog Thomas Betts

• Lightweight and robust for easy carriage

• Free standing on base plate for stable use

in high winds

• Fully portable (carrying handle)

• Including accessories, cable gland & lamps installed

Approvals / Characteristics Features

84

HF RangePortable fl oodlight

Thomas & Betts • www.tnb-hazardous.com

Page 85: Catalog Thomas Betts

Nominal

Type Rating (W) Lamp Power Supply (V) Current (A) Weight (kg)

HF55P-00000 55 Halogen H3 12 4.6 6

HF70P-00000 70 Halogen H3 24 2.9 6

Industrial Lighting - HF Range

Technical Specifi cations

85

EnclosureMarine grade aluminium alloy Yellow polyurethane paint RAL1003Globe: 3mm thick transparent polycarbonateTemperatureAmbient temperature: -20°C to +60°C

Cable entriesOne M20 entry includedOne cable gland - ISO M20 Nylon, diameter 8-13mmMetallic cable gland for non-armoured cable or armoured cable on requestTerminal blockUp to 6mm2

Lamps (supplied)70W - 24V iodine lamp - H3 lampholder55W - 12V iodine lamp - H3 lampholderFixingTreated steel support with base plate ref. SA103

Dimensions

Related Products

Spares & Fixings Accessories see pages 94-99

EXL Conduit 140 Stopping Plugs 164 GUV Range 124 PA Gland 150

Thomas & Betts • www.tnb-hazardous.com

Page 86: Catalog Thomas Betts

86

FR-EM / FF-EM RangeEmergency weatherproof tubular fl uorescent fi tting

Approvals / Characteristics Features

• Ingress protection IP66 ideal for wash down areas

• All componets mounted on hinged and removable gear tray

which gives easy access for installation and maintenance

• Battery 2h duration

• Including accessories, cable gland & fixing brackets

Thomas & Betts • www.tnb-hazardous.com

Page 87: Catalog Thomas Betts

Industrial Emergency Lighting - FR-EM / FF-EM Range

Technical Specifi cations

87

Related Products

EnclosureReinforced black polycarbonate end capsLEXAN 2034 UV protected extruded polycarbonate tube, thickness 2.5mmTemperatureAmbient temperature: -10°C to +40°CFixingStandard: D023 - 2 Zinc Plated Steel articulated brackets for ceiling mounting

Power FactorSuperior to 0.98Rated voltagesElectronic ballast: AC/DC 220-240V, 50-60HzBatteryNi-Cd battery 7.2V, 4AhLumen output in emergency mode (1 tube lit):40% for 8W, 33% for 36WBattery duration in emergency mode: 2 hoursMonitored by one LEDCable entriesStandard: Two M20 entries includedOne cable gland - ISO M20 Nylon, diameter 8-13mm

Terminal block (plug in terminal block)Up to 10mm2 (rigid wire), 6mm2 (fl exible wire)Standard: terminals supplied for L, N, PE Lamps (order separately)T8 bi-pin G13 tube, Ø 26 - white industry 4000°KG11 compact fl uorescent PL lamp

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Nominal Dimensions (mm)

Type Confi guration Diffuser Rating (W) Current (A) Battery A B Weight (kg)

FR120EM-0G000 3 Wire loop Polycarbonate 1 x 18 0.15 2h 780 565 8

FR140EM-0G000 3 Wire loop Polycarbonate 1 x 36 0.2 2h 1385 1170 8

FF220EM-0G000 3 Wire loop Polycarbonate 2 x 18 0.2 2h 780 565 8

FF240EM-0G000 3 Wire loop Polycarbonate 2 x PL36 0.35 2h 1385 1170 8

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 88: Catalog Thomas Betts

• Double central locking: for easy installation

and ingress protection

• Battery duration 2 hours

• Including accessories, cable gland & fixing brackets

88

EVT-EM RangeEmergency weatherproof fl uorescent fi tting with diffuser

Approvals / Characteristics Features

Thomas & Betts • www.tnb-hazardous.com

Page 89: Catalog Thomas Betts

Industrial Emergency Lighting - EVT-EM Range

Technical Specifi cations

89

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuserTemperatureAmbient temperature: -10ºC to +40ºCFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesElectronic ballast: AC/DC 220-240V, 50-60HzBatteryNi-Cd 7.2V battery 4AhLumen level in emergency mode (1 tube lit):40% for 18W, 33% for 36WBattery duration in emergency mode:2 hoursBattery charge monitored by LEDPower factor0.98 with electronic ballastCable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs andOne cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFor armoured cable - continuity plate option:Nickel Brass cable gland (1 and 2 according to number of plates)

Terminal block (plug in terminal block)Up to 6mm² (rigid wire), 4mm² (fl exible wire)Select function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)T8 bi-pin G13 tube, Ø 26 - cool white 4000°K

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) A B C Weight (kg)

EVT120EM-00J0 3 Wire Loop 1 x 18 2h 0.09 785 170 432 6.5

EVT120EM-A0J0 5 Wire Loop 1 x 18 2h 0.09 785 170 432 6.5

EVT120EM-B0J0 5 Wire Through 1 x 18 2h 0.09 785 170 432 6.5

EVT140EM-00J0 3 Wire Loop 1 x 36 2h 0.17 1370 170 900 8.5

EVT140EM-A0J0 5 Wire Loop 1 x 36 2h 0.17 1370 170 900 8.5

EVT140EM-B0J0 5 Wire Through 1 x 36 2h 0.17 1370 170 900 8.5

EVT220EM-00J0 3 Wire Loop 2 x 18 2h 0.17 785 170 432 7.5

EVT220EM-A0J0 5 Wire Loop 2 x 18 2h 0.17 785 170 432 7.5

EVT220EM-B0J0 5 Wire Through 2 x 18 2h 0.17 785 170 432 7.5

EVT240EM-00J0 3 Wire Loop 2 x 36 2h 0.33 1370 170 900 10.5

EVT240EM-A0J0 5 Wire Loop 2 x 36 2h 0.33 1370 170 900 10.5

EVT240EM-B0J0 5 Wire Through 2 x 36 2h 0.33 1370 170 900 10.5

*EVT... EM-C0J0 - 3 Wire loop & continuity plate*EVT... EM-E0J0 - 5 Wire through & 2 continuity plates

170

137

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 90: Catalog Thomas Betts

• Double central locking: for easy installation

and ingress protection

• Battery life 3 hours with battery charge monitor

• Including accessories, cable gland & fixing brackets

90

EVT-EMA RangeEmergency weatherproof fl uorescent fi tting with diffuser

Approvals / Characteristics Features

Thomas & Betts • www.tnb-hazardous.com

Page 91: Catalog Thomas Betts

Industrial Emergency Lighting - EVT-EMA Range

Technical Specifi cations

91

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

Wiring Battery 3h+ Nominal Dimensions (mm)

Type Confi guration Rating (W) Auto Test Current (A) A B C Weight (kg)

EVT120EMA-A0J0 5 Wire Loop 1 x 18 3h 0.09 785 170 432 6.5

EVT140EMA-A0J0 5 Wire Loop 1 x 36 3h 0.17 1370 170 900 8.5

EVT140EMA-B0J0 5 Wire Through 1 x 36 3h 0.17 1370 170 900 8.5

EVT220EMA-A0J0 5 Wire Loop 2 x 18 3h 0.17 785 170 432 7.5

EVT240EMA-A0J0 5 Wire Loop 2 x 36 3h 0.33 1370 170 900 10.5

EVT240EMA-B0J0 5 Wire Through 2 x 36 3h 0.33 1370 170 900 10.5

170

137

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 136 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

EnclosureFibreglass reinforced polyester bodyPolycarbonate diffuserPower factorSuperior to 0.98Cable entriesStandard: Three M20 cable entries includedTwo M20 Nylon plugs and One cable gland - ISO M20 Nylon, diameter 8-13mm for non-armoured cableFixingStandard: V015 - 2 Zinc Plated Steel brackets for ceiling mounting

Rated voltagesElectronic ballast: AC/DC 220-240V, 50-60HzFor other voltages contact SalesBatteryNi-Cad 6V 4Ah for 18W / Ni-Cad 6V 7Ah for 36W Battery in fl ameproof case (Auto cut out of defective light)Lumen output in emergency mode (1 tube lit): 40% at 18W, 33% at 36WBattery duration: 3h max 36WPreventive maintenance - Self test- Battery charge - daily- Emergency lamp during 1min - weekly- Battery charge capacity during 1hr - quaterly- Clean system test displayBattery charge monitored by 2 LED

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Command must be supplied with switch on lineLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

Healthy(test OK)

Emergency or Indicator

Lamp Fault

Test inProgress

(waiting end

Fault(replacebattery)

Page 92: Catalog Thomas Betts

• Fitting combines photometric qualities, strength

and design

• Easy access to components

• Battery duration 2 hours

• Including accessories & cable gland

Approvals / Characteristics Features

92

EST-EM RangeEmergency weatherproof recessed fl uorescent fi tting

5

Thomas & Betts • www.tnb-hazardous.com

Page 93: Catalog Thomas Betts

Industrial Emergency Lighting - EST-EM Range

Technical Specifi cations

93

Related Products

Dimensions

Spares & Fixings Accessories see pages 94-99

EnclosureSteel housing and body painted in white polyester powder paint RAL 90166mm clear toughened glass panel (optional frosted low lumen output) Neoprene gasketTemperatureOperating temperature range:-10°C to +40°C

Rated voltagesElectronic ballast:Standard: AC/DC 220-240V, 50-60HzFor other voltages contact SalesBattery: Ni-Cd 6V 7Ah batteryLumen level in emergency mode (1 tube lit): 33% Emergency load duration: 2 hoursBattery charge monitored by LEDPower factorSuperior to 0.98Cable entriesStandard: Two M20 cable entries includedOne M20 Nylon plug andOne cable gland - ISO M20 Nylon, diameter 8-13mm

Terminal blockUp to 4mm² (rigid wire), 2.5mm² (fl exible wire)Terminals for L, N, PE terminal 1 and terminal 2Select function: Lighting in maintained mode or lighting in non-maintained modeLamps (order separately)Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k

240

240

Wiring Nominal Dimensions (mm)

Type Confi guration Rating (W) Battery Current (A) Glass A B C Weight (kg)

EST240EM-00J0 3 Wire Loop 2 x 36 2h 0.33 Toughened 1364 1312 105 22

EST240EM-A0J0 3 Wire Loop 2 x 36 2h 0.33 Frosted 1364 1312 105 22

Thomas & Betts • www.tnb-hazardous.com

EXB Conduit 138 Nylon Stopping Plugs 164

Exe Nylon Gland 166XB100 Range 108

Page 94: Catalog Thomas Betts

Fixing Accessories

94

,602 Ø 8.5

Fixing Accessories for EV Fluorescent Light Fitting Range

3 5

Ø11

35 35

Ø8

R

55

35 3

2 Ø 113

Fixing Accessories for XFF / XFR / XFP / XEL / XEP / XFF-EM / XFP-EM Range

Fixing Accessories for DTS lighting fi ttings

U-bolt for pole mountingfor 1”1/4

D025: zinc plated steel

BracketStandard D023: zinc plated steel

D024: stainless steel

fl 9

20 30

60¡maxi

30

2

10070

2 x fl 9

fl 36fl 20

M 8

18

25

M8

100

41ø9

~70α

25 ø9

25160200

2 oblong holes18x9

Hinged bracketV023: plastic coated

HookV024: zinc plated steel

Fixing bracket and fl ange for ø 1”1/4 and 1”1/2

V018: zinc plated steel (V015 - 2”)V021: stainless steel (V022 - 2”)

BracketsStandard V015: zinc plated steel

V016: stainless steel

Mounting bracket clipV014: stainless steel

Thomas & Betts • www.tnb-hazardous.com

Page 95: Catalog Thomas Betts

Spare Parts

Accessories & Spare Parts

95

Spare Parts for EV Fluorescent Light Fitting Range

005003

002

004008009

007002

004

001

Spare Parts for DTS lighting fi ttings

EVS RangeType Specifications

V001 Transparent diffuser

V002 Gasket

V004 Complete gear tray*

V005 XIN switch

V006 Exe terminal block

V008 G13 bi-pin lampholder

EVN / EVD RangeType Specifications

V001 Transparent diffuser

V002 Gasket

V004 Complete gear tray*

V005 XIN switch

V006N Terminal block

V007N Electronic ballast*

V008N Bi-pin lampholder

ESB / ESB-EM RangeType Specifications

Z001 Transparent frame

V003 Box cover

V005 XIN switch

V006 Exe terminal block

V007 Electronic ballast Exd* (ESB)

V012A Electronic ballast Exd* (ESB-EMA)

V008 G13 bi-pin lampholder

Spare Parts for ESB / ESB-EM Range

*Defi ne type, rating and operating voltage

*Defi ne type, rating and operating voltage

005

003

007

008

001

Thomas & Betts • www.tnb-hazardous.com

Page 96: Catalog Thomas Betts

P

96

Spare Parts

Spare Parts for XFF / XFR Range

XFF / XFR RangeType Specifications

D001 Tube (+ D002, + D003, +D011)

D003 Gasket

D004 Slide for gear tray

D005 Sliding gear tray*

D006 Connector

D007 Starter socket

Type Specifications

D008 Starter

D009 Ballast*

D009E Electronic ballast

D010 Lamp holder

D010PL G11 lampholder for PL

*Specify rating plus voltage

Spare Parts for DTS lighting fi ttings

Spare Parts for XFP Range

XFP RangeType Specifications

D001P Tube (+ D002, + D003, +D011)

D003 Gasket

D004 Slide for gear tray

D005 Sliding gear tray*

D006 Connector

D007 Starter socket

Type Specifications

D008 Starter

D009 Ballast*

D009E Electronic ballast

D010 Lamp holder

D010PL G11 lampholder for PL

*Specify rating plus voltage

Type Specifications

D017 Box gasket

D018 Box cover

D019 Screw for box cover

D020 Terminal block

D021 Switch

D022 Interlock

Thomas & Betts • www.tnb-hazardous.com

Page 97: Catalog Thomas Betts

Accessories & Spare Parts

97

Spare Parts

Spare Parts for DTS lighting fi ttings

*Specify rating plus voltage

Thomas & Betts • www.tnb-hazardous.com

Spare Parts for XEL / XEP Range

*Specify rating plus voltage

XEL

XEP

Spare Parts for XF Range

XF RangeType Specifications

P001 Closing screw

P002 Sealed front glass

P004 Gasket

P006 Lamp*

P007 Lampholder E40

P008 Reflector

P009 Ballast 230 / 240V (150, 250, 400W)*

P010 Ballast 120V (400W)

Type Specifications

P012 Starter

P015 Safety support cable

P017 Mounting bracket

P018 Support screw

P019 Terminal block 2 x 6

P021 Earthing terminal

P022 Box gasket

P023 Box cover

XEL / XEP RangeType Specifications

B001 Tube (+ D002, + D003, + D011)

D003 Gasket

B004 Slide for gear tray

M005.1 Sliding gear tray - XEL300/8*

M005.2 Sliding gear tray - XEL300/28*

M005.3 Sliding gear tray - XEL30011

M005.4 Sliding gear tray - XEL120*

Type Specifications

M005.5 Sliding gear tray - XEL220*

D006 Connector

D007 Starter socket

D008 Starter

D009 Ballast

D010 Lampholder

D010PL G11 lampholder for PL lamps

Type Specifications

D017 Box gasket

D018 Box cover

D019 Screw for box cover

D20 Terminal block

D021 Switch

D022 Interlock

Type Specifications

P025 Cover screw

P026 Cable gland

P030 Ex through wiring connector

E006 Optic

E007 70W iodine lamp

E008 Gear tray support

E009 Attachment for optic

Page 98: Catalog Thomas Betts

98

Spare Parts

Spare Parts for XFF-EM / XFP-EM Range

*Specify rating plus voltage

Spare Parts for DTS lighting fi ttings

Spare Parts for EV Range

EV RangeType Specifications

D002 Cover

D003 Gasket

D004 Slide for gear tray

D005 Sliding gear tray*

D006 Connector

D007 Starter socket

Type Specifications

D008 Starter

D009 Ballast*

D009E Electronic ballast

D010 Lamp holder

D010PL G11 lampholder for PL

D011 Chain

*Specify rating plus voltage

XFF-EM RangeType Specifications

D001 Tube (+ D002, + D003, +D011)

D003 Gasket

D004 Slide for gear tray

D005 Sliding gear tray*

D006 Connector

D007 Starter socket

Type Specifications

D008 Starter

D009 Ballast*

D009E Electronic ballast

D010 Lamp holder

D010PL G11 lampholder for PL

XFP-EM RangeType Specifications

D001P Tube (+ D002, + D003, + D011)

D003 Gasket

D004 Slide for gear tray

D005 Sliding gear tray*

D006 Connector

D007 Starter socket

Type Specifications

D008 Starter

D009 Ballast*

D009E Electronic ballast

D010 Lamp holder

D010PL G11 lampholder for PL

D017 Box gasket

Type Specifications

D018 Box cover

D019 Screw for box cover

D020 Terminal block

D021 Switch

D022 Interlock

Thomas & Betts • www.tnb-hazardous.com

Page 99: Catalog Thomas Betts

Spare Parts for XDF Range

XDF RangeType Specifications

XF001 Gear cover

FF002 Cover fixing screw

FF003 Cover gasket

FF004 Starter switch

FF005 Starter socket

FF006 Ballast 120VAC - 50Hz

FF007 Ballast 120VAC - 60Hz

FF008 Ballast 208/220VAC - 50Hz

FF009 Ballast 208/220VAC - 60Hz

Type Specifications

FF010 Ballast 240VAC - 50Hz

FF011 Ballast 240VAC - 60Hz

XFF012 Lamp holder

XFF013 Body

FF014 Mounting brackets

FF015 Beam mounting brackets

FF016 Stainless steel tube support bracket

FF017 Bi pin tube

Type Specifications

FF018 Fixing screws

FF019 Connecting terminals

FF020 Earthing terminal

FF021 Lamp cover

FF022 M20 cable gland

FF023 3 pole 10A male connector

FF024 3 pole 10A female connector

FF025 Protective cap

99

Accessories & Spare Parts

Spare Parts

Spare Parts for DTS lighting fi ttings

Spare Parts for XEL-BAES Range - XEL / XEP

XFF / XFR RangeType Specifications

B001 Tube (+ D002, + D003, + D011)

B001P Tube (+ D002, + D003, + D011)

D003 Gasket

B004 Sliding gear tray

B005B Gear tray - XEL80A

B006 Gear tray - XEL300

B006L Gear tray - XEL300/1

B007 Gear tray - XEL300/2

Type Specifications

B008B Batteries - XEL80

B009A Batteries - XEL300A

B010B Gear tray - XEL80AK / AI

B011 Gear tray - XEL300AK

B013 Gear tray - XEL300A

B013K Gear tray - XEL300AK

B014B Gear tray - XEL80SI*

B015 Gear tray - XEL300SI*

*Specify address number

Type Specifications

B016 Kit - XEL80K

B017 Kit - XEL300K

D017 Box gasket

D018 Box cover

D019 Screw for box cover

D20 Terminal block

D021B Switch

D022 Interlock

Thomas & Betts • www.tnb-hazardous.com

001002

003

004

005006007

012

012

013

014

015

014015

016

008009010011

019

017

020

022023024

025

018

003

002

021

XEP

XEL

Page 100: Catalog Thomas Betts

Compact fluorescent lampsSpecifications: PN Power (W) Flux (lm) Cap Lighting equipment Reference

PL7W 7 400 G23 Miniature XEL / XEP...

PL9W 9 600 G23 Weatherproof miniature EL...

PL11W 11 900 G23 Fluorescent XFR / XFF / XFP

PL18W 18 1200 2 G11

PL36W 36 2900 2 G11

PL55W 55 4800 2 G11

LED lampsSpecifications: Power (W) Flux (lm) Cap Lighting equipment Reference

8 345 E27 Beacon XFB

12 806 E27 Weatherproof beacon FB

E27

CRI: 80 - Lm/W: 55

Colour temperature: 3000K

Average life: 25,000 hours

Integral electronic ballast

For Part Number - Contact Sales

100

Lamps Guide

Bi-pin T8/T12 fluorescent tubesSpecifications: PN Power (W) Flux (lm) Cap Lighting equipment Reference

TL18W 18 1250 G13 Fluorescent EVS...

TL36W 36 3350 G13 Fluorescent XFR / XFF / XFP...

TL58W 58 5200 G13 Fluorescent EVN...

Fluorescent EVD...

Weatherproof fluorescent EVT... FR/FF

Guide to Lamps for use in DTS lighting fi ttings

Miniature T5 fluorescent tubesSpecifications: PN Power (W) Flux (lm) Cap Lighting equipment Reference

TL8W 8 430 G5 Miniature XEL / XEP...

Weatherproof miniature EL...

BAES range XEL BAES...

G5 - ø 15mm

CRI: 60 > 85 - Lm/W: 51 > 59

Colour temperature:

2700K > 4100K

Average life: 6,000 hours

Electronic ballast or inverter

G13 - ø 26mm or ø 38mm

CRI: > 80 - Lm/W: 65 > 93

Colour temperature:

2700K > 6500K

Average life: 6,000 > 10,000 hours

Standard or electronic ballast

Thomas & Betts • www.tnb-hazardous.com

Halogen lampsSpecifications: Power (W) Flux (lm) Cap Lighting equipment Reference

28 345 E27 Beacon XFB

70 1200 E27 Wellglass EVX / EVH

140 3000 E27 Weatherproof beacon FB

CRI: 100 - Lm/W: 10 > 17

Colour temperature:

2700K

Average life: 1,000 hours

For Part Number - Contact Sales

G23 or G11

CRI: 85 > 90 - Lm/W: 57 > 87

Colour temperature:

2700K > 4000K

Average life: 20,000 hours

Standard or electronic ballast,

inverter

Page 101: Catalog Thomas Betts

101

Lamps Guide

High pressure sodium tubular lampsSpecifications: NP Power (W) Flux (lm) Cap Lighting equipment Reference

P00670SHP 70 6000 E40 Ex d floodlight XSF...

P006150SHP 150 45000 E40 Weatherproof floodlight SF...

P006250SHP 250 28000 E40

P006400SHP 400 48000 E40

Guide to Lamps for use in DTS lighting fi ttings

Metal halide tubular lampsSpecifications: NP Power (W) Flux (lm) Cap Lighting equipment Reference

P006250IM 250 20000 E40 Ex d floodlight XQF...

P006400IM 400 42000 E40 Weatherproof floodlight QF...

Halogen lampsSpecifications: NP Power (W) Flux (lm) Cap Lighting equipment Reference

S00755W 55 1350 H3 Ex d floodlight XEF / XHF...

S00770W 70 1770 H3 Weatherproof floodlight EF / HF...

H3

CRI: 100 - Lm/W: 25

Colour temperature:

3000K

Average life: 1,000 hours

CRI: 65 - Lm/W: 68 > 76

Colour temperature:

4300K > 4600K

Average life: 3,000 > 6,000 hours

Mimimum starting temperature: -25ºC

Time to full power: 5 > 10mm

With control gear and ignitor

CRI: NS - Lm/W: 100 > 120

Colour temperature: 2100K

Average life: 15,000 > 20,000 hours

Mimimum starting temperature: -30ºC

Time to full power: 1 > 10mm

With control gear and ignitor

Metal halide egg-shaped lampsSpecifications: Power (W) Flux (lm) Cap Lighting equipment Reference

250 12700 E40 Ex d wellglass EVX

400 22000 E40

250 12700 E40

400 22000 E40

High pressure sodium egg-shaped lampsSpecifications: Power (W) Flux (lm) Cap Lighting equipment Reference

70 6300 E27 Ex d wellglass EVX / EVH Na...

150 17000 E40

250 31100 E40

400 55500 E40

CRI: NS - Lm/W: 80 > 125

Colour temperature:

2000K > 2200K

Average life:

34,000 hours

Mimimum starting temperature: -25ºC

Time to full power: 1 > 10mm

With control gear and ignitor

For Part Number - Contact Sales

Thomas & Betts • www.tnb-hazardous.com

CRI: 33 > 49 - Lm/W: 50 > 60

Colour temperature:

3900K > 4300K

Average life: 15,000 > 20,000 hours

Mimimum starting temperature: -25ºC

Time to full power: 5 > 10mm

With control gear

For Part Number - Contact Sales

Page 102: Catalog Thomas Betts

EVH 100 (Halogen) EVX 100 (Halogen)

EVX Range - Halogen Dimensions (mm)

Type Rating (W) Lamps Nominal (A) A/A’ B Tº Class Weight in (kg)

EVX100-00000 70 E27 Halogen 0.45 250/283 150 T4 2.9

EVX200-00000 140 E27 Halogen 0.90 313/346 170 T3 3.5

EVX300-00000 250 E27 Mixed light 1.30 410/463 220 T3 7.2

*EVH version, remove X and add H, e.g. EVH120-00000

102

EnclosureBody in marine grade aluminium alloy (CU<0.05%) Yellow polyurethane paint RAL1003Borosilicate glass globeGalvanised steel protection grillIngress rating: IP65 (EN60529), neoprene ingress gasketStainless steel screwsTemperatureAmbient temperature range:-20°C to +60°C Surface temperature classifi cation: T4 to T3 (gas)

Rated voltagesHP Sodium metal halide Standard: 230V 50Hz compensated, wirewound ballastPower factor0.85 (HP Sodium and metal halide)Cable entriesEVH: four 3/4” NPT entries - fi tted 2 plugsEVX: four 3/4” NPT entries - fi tted 2 plugsTerminal blockUp to 6mm² (rigid wire), 4mm² (fl exible wire)

LampsNot suppliedFixingCeiling screw M8 (EVX)Suspension ring (EVH)Spare part: 30º angle wall mounting arm (R018)

EC TYPE Examination Certificate:IECEx CES 07.0004CESI 12 ATEX 006GOST RII 2 GDEx d IIC T...ºC GbEx tb IIIC T...ºC Db IP66

Lamps Guide

EV Range - Wellglass, Lantern or High Bay FIttings

EVX / EVH Range

Thomas & Betts • www.tnb-hazardous.com

Page 103: Catalog Thomas Betts

EVH Na (HP Sodium) EVX Na (HP Sodium) EVH Im (Metal Halide) EVX Im (Metal Halide)

Lamps Guide

103

EnclosureBody in marine grade aluminium alloy (CU<0.05%) Yellow polyurethane paint RAL1003Borosilicate glass globeGalvanised steel protection grillIngress rating: IP65 (EN60529), neoprene ingress gasketStainless steel screwsTemperatureAmbient temperature range:-20°C to +60°C Surface temperature classifi cation: T4 to T3 (gas)

Rated voltagesHP Sodium metal halide Standard: 230V 50Hz compensated, wirewound ballastPower factor0.85 (HP Sodium and metal halide)Cable entriesEVH: four 3/4” NPT entries - fi tted 2 plugsEVX: four 3/4” NPT entries - fi tted 2 plugsVariants: Other options available on requestTerminal blockUp to 6mm² (rigid wire), 4mm² (fl exible wire)

LampsNot suppliedFixingCeiling screw M8 (EVX)Suspension ring (EVH)Spare part: 30º angle wall mounting arm (R018)

EC TYPE Examination Certificate:IECEx CES 07.0004CESI 12 ATEX 006GOST RII 2 GDEx d IIC T...ºC GbEx tb IIIC T...ºC Db IP66

EV Range - Wellglass, Lantern or High Bay FIttings

EVXNa / EVXlm / EVHNa / EVHlm Range

EVXNa Range - HP Sodium Dimensions (mm)

Type Rating (W) Lamps Nominal (A) A/A’ B TºC Class Weight in (kg)

EVXNa20-00000 70 E27 Egg shaped 0.40 470/500 200 T4 6.5

EVXNa30-00000 150 E40 Egg shaped 0.80 600/633 220 T3 9.7

EVXNa40-00000 250 E40 Egg shaped 1.30 600/633 220 T3 9.7

EVXNa50-00000 400 E40 Egg shaped 2.10 630/670 270 T3 12

*EVH version, remove X and add H, e.g. EVHNa120-00000

EVXlm Range - Metal Halide Dimensions (mm)

Type Rating (W) Lamps Nominal (A) A/A’ B TºC Class Weight in (kg)

EVXlm40-00000 250 E40 Egg shaped 1.30 600/633 220 T3 9.7

EVXlm50-00000 400 E40 Egg shaped 2.10 630/670 270 T3 12

*EVH version, remove X and add H, e.g. EVHlm120-00000

Thomas & Betts • www.tnb-hazardous.com

Page 104: Catalog Thomas Betts

Ex Boxes & EnclosuresEx Boxes & Enclosures

26104

Thomas & Betts • www.tnb-hazardous.com

Page 105: Catalog Thomas Betts

Ex Boxes & Enclosures

105

Thomas & Betts • www.tnb-hazardous.com

Page 106: Catalog Thomas Betts

Prot

ectio

n Ty

pe

106

Ex Boxes & Enclosures Range

Ex Boxes & Enclosures - Selection Guide

Thomas & Betts • www.tnb-hazardous.com

XBL InstrumentBoxes Page 112

XBInstrumentBoxes Page 116

XB-AControlBoxes Page 118

XBL Junction Boxes Page 108

XBi-AControlBoxes Page 122

XBiInstrumentBoxes Page 120

Gas

Gro

ups

Dus

tG

roup

Zo

nes

XBL-AControlBoxes Page 114

Page 107: Catalog Thomas Betts

Ex Boxes & Enclosures - Selection Guide

107

Thomas & Betts • www.tnb-hazardous.com

EFDCControlBoxes Page 126

GUVJunction Boxes Page 124

EJBCustom Built Panel Page 128

SRCControlBoxes Page 126

XMCControlBoxes Page 126

Page 108: Catalog Thomas Betts

• External mounting points allowing for junction boxes to be mounted without the need for the removal of lid• Robust design• Manufactured from anti static GRP so eliminating any chance of static build up• Supplied complete with terminals and glands so all

on site combinations are covered

Approvals / Characteristics Features

108

XBL RangeXB100 Junction boxes

Certifi cation & StandardsApproved to: EN60079-0, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/ECLCIE 11 ATEX 3049X / IECEx LCI 11.0045XEx II 2 G / II 2 DEx e II T6 to T5Ex tD A21 IP66 T85ºC to T100ºCT6: -20ºC to 40ºCT5: -20ºC to 55ºCGlow wire test: 960ºC EN60598-2-22

Thomas & Betts • www.tnb-hazardous.com

Page 109: Catalog Thomas Betts

XFF Range 28 EVS Range 42 Exe Nylon Gland 166

Ex Boxes & Enclosures - XBL Range

Technical Specifi cations

109

Related Products

Dimensions

Stopping Plugs 164

AVERTISSEMENT- NE PAS OUVRIR SOUS TENSIONWARNING- DO NOT OPEN WHILE ENERGIZED

32

121

121

R3.2

100

100

75.5

No. of Glands Plug No. of Terminal Plate Bonding

Type Entries Material Gland Size Thread Size Provided Connectors Type Section Conncetion Conductors

XB100-6BV 4 Poly M20a 8-13mm 1 x M20 6 4 x Grey 6mm2 bridge x2 Screw/Screw –

2 x 6mm2 bridge x2 Screw/Screw –

XB100-6BR 4 Poly M20a 8-13mm 1 x M20 6 4 x Grey 4mm2 bridge Spring/Spring –

2 x 4mm2 bridge Spring/Spring –

XB100-10BV 4 Poly 3 x M20a 8-13mm 1 x M20 6 4 x Grey 10mm2 bridge x2 Screw/Screw –

1 x M32 17-25mm 2 x 10mm2 bridge x2 Screw/Screw –

XB100A-6BV 4 Nickel Plated Brass M20T6* 6-12mm Int. 1 x M20 6 4 x Grey 6mm2 bridge x2 Screw/Screw Yes

8.5-16mm Ext. 2 x 6mm2 bridge x2 Screw/Screw

XB100A-6BR 4 Nickel Plated Brass M20T6* 6-12mm Int. 1 x M20 6 4 x Grey 4mm2 bridge x2 Spring/Spring Yes

8.5-16mm Ext. 2 x 4mm2 bridge x2 Spring/Spring

XB100A-10BV 4 Nickel Plated Brass 3 x M20T6* 6-12mm Int. 1 x M20 6 4 x Grey 10mm2 bridge x2 Screw/Screw Yes

8.5-16mm Ext.

1 x M32T8* 12-21mm Int. 2 x 10mm2 bridge x2 Screw/Screw

16-27.5mm Ext.

*For reinforced cable EGFA

Thomas & Betts • www.tnb-hazardous.com

Page 110: Catalog Thomas Betts

Approvals / Characteristics Features

110

XBL RangeJunction boxes

Certifi cation & Standards

• Robust design• Manufactured from anti static GRP so eliminating any chance of static build up• Supplied complete with terminals and glands so all on site combinations are covered

Approved to: EN60079-0, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/ECLCIE 11 ATEX 3049X / IECEx LCI 11.0045XEx II 2 G / II 2 DEx e II T6 to T5Ex ia IIC T6Ex tD A21 IP66 T85ºC to T100ºCT6: -20ºC to 40ºCT5: -20ºC to 55ºCGlow wire test: 960ºC EN60598-2-22

Thomas & Betts • www.tnb-hazardous.com

Page 111: Catalog Thomas Betts

EJB Range 128 EVS Range 42 Exe Nylon Gland 166

Ex Boxes & Enclosures - XBL Range

Glands Plug No. of Terminal Plate Bonding

Type No. of Entries Material Gland Size Thread Size Provided Connectors Section Connection Conductors

XBL28-25BR 6 Poly M20a 8-13mm 1 x M20 3 8 x 2, 5mm2 deck Spring/Spring –

XBL26-25R 4 Poly M20a 8-13mm 1 x M20 3 4 x 2, 5mm2 deck Spring/Spring –

Technical Specifi cations

111

Related Products

Dimensions

Stopping Plugs 164

110

75

25

75.5

AVERTISSEMENT- NE PAS OUVRIR SOUS TENSIONWARNING- DO NOT OPEN WHILE ENERGIZED

25

81

81

R6.5

75.5

XB10-SI Boxes for connecting SI Sensors (for Instrumentation Box Zone 0 Products)

Dimensions

No. of Glands Plug No. of Terminal Plate Bonding

Type Entries Material Gland Size Thread Size Provided Connectors Colour Section Connection Conductors

XB10-SI 3 Poly (Blue) M16b 6-10mm 1 x M16 6 4 x Blue 2.5mm2 Screw/Screw –

2 x V/J 2.5mm2 Screw/Screw –

XB10A-SI 3 Poly (Blue) M16b 8-13mm 1 x M16 6 4 x Blue 2.5mm2 Screw/Screw Yes

Nickel Plated Brass M20T6* 6-12mm Int. 2 x V/J 2.5mm2 Screw/Screw

8.5-16mm Ext.

*For reinforced cable EGFA

Type Connection Nominal Section Maximum Intensity

XB10-SI Rigid 0.5 - 6mm2 21A

Semi Rigid 0.5 - 4mm2

XB10A-SI Flexible 0.5 - 4mm2 21A

Flexible Tip 0.5 - 2.5mm2

Thomas & Betts • www.tnb-hazardous.com

Page 112: Catalog Thomas Betts

112

XBL RangeInstrumentation boxes

• Robust design• Manufactured from ant static GRP so eliminating any chance of static build up• Can be supplied complete with terminals and glands so

all on site combinations are covered

Approvals / Characteristics Features

Certifi cation & StandardsApproved to: EN60079-0, 60079-1, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/EC LCIE 11 ATEX 3049X / IECEx LCI 11.0045XEx II 2 G / DEx e or ia or eia IIC T6, T5 or T4Ex tD A21 IP66 T85ºC, T100ºC or T135ºCT4: ≤ -20ºC to ≤ +90ºCT5: ≤ -20ºC to ≤ +55ºCT6: ≤ -20ºC to ≤ +40ºCLCIE 11 ATEX 3035 U / IECEx LCI 11.0028UEx e IIEx tD A21 IP66Glow wire test: 960°C EN60598-2-22

Thomas & Betts • www.tnb-hazardous.com

Page 113: Catalog Thomas Betts

Ex Boxes & Enclosures - XBL Range

Technical Specifi cations

113

Related Products

Dimensions

EnclosureGlass fi bre reinforced polyester with graphite fi nish (R<1G Ohm)Stainless steel unlosable screwsOptional hinges

Rated voltagesDependent on the components fi tted in the box (eg:with terminal block: Un max = 500V)Cable entriesISO entries and threadsNylon cable glands for non-armoured cableNickel chromed brass cable glands for non-armoured cableNickel chromed brass PE series cable glands for armoured cable PEP series with brass continuity plate on XBL

Terminal block Equipment of the terminal lock wire any type of certifi ed Exe or Exia terminals. The maximum number of terminal blocks per box isdependent on the certifi cationStainless steel external earthOther options available upon request

Maximum number of terminals

Dimensions (mm) size (in mm2) / In Max (in A) Weight in

Type Material A B C D E 2.5/21 4/28 6/36 10/50 16/66 35/109 70/167 70/95/100 120/234 185/307 240/350 (kg)

XBL15 Poly 122 120 91 106 82 13 11 8 6 – – – – – – – 0.8

XBL20 Poly 110 75 75 98 45 11 (Min) 9 (Min) – – – – – – – – – 0.4

XBL25 Poly 220 120 91 204 82 33 28 21 16 – – – – – – – 1.1

XBL35 Poly 360 160 91 340 110 60 50 38 30 25 – – – – – – 2.2

XBL40 Poly 405 400 121 380 355 204 171 129 68 58 21 – – – – – 5.6

XBL45 Poly 400 250 121 380 200 136 114 86 34 29 21 – – – – – 3.7

XBL55 Poly 400 250 161 380 200 136 114 86 34 29 21 17 – – – – 4.8

XBL65 Poly 600 250 121 580 200 216 180 136 54 45 34 – – – – – 5.2

XBL75 Poly 405 605 252 370 570 312 261 130 104 86 32 25 19 6 5 5 7.2

For mounting ø 06.5

Thomas & Betts • www.tnb-hazardous.com

EJB Range 128 EVS Range 42 Exe Nylon Gland 166Stopping Plugs 164

For full details and design service contact Sales

Page 114: Catalog Thomas Betts

• Wide variety of sizes and functions available as standard products for speed of supply and custom

built to meet the end users exact requirements• All manufactured with approved components• Manufactured from anti static GRP so eliminating any chance of static build up

Approvals / Characteristics Features

114

XBL-A RangeStandard control boxes

Certifi cation & StandardsApproved to: EN60079-0, 60079-1, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/EC LCIE 11 ATEX 3049X / IECEx LCI 11.0045XEx II 2 G / DEx de or e or ia or eia IIC T6, T5 or T4Ex tD A21 IP66 T85ºC, T100ºC or T135ºCT4: ≤ -20ºC to ≤ +90ºCT5: ≤ -20ºC to ≤ +55ºCT6: ≤ -20ºC to ≤ +40ºCGlow wire test: 960ºC EN60598-2-22

Thomas & Betts • www.tnb-hazardous.com

Page 115: Catalog Thomas Betts

Ex Boxes & Enclosures - XBL-A Range

Technical Specifi cations

115

Related Products

Dimensions

EnclosureXBL-A: Glass fi bre reinforced polyester with graphite fi nish (R< 1 Gohm)Stainless steel unlosable screws Optional hingesProtection class: ITechnical CharacteristicsAC: U = 415V max. I = 1,75A or U = 240V, I = 3A orU = 120V, I = 6A DC: U = 415V max. I = 0,165A or U = 250V, I = 0,27A or U = 125V, I = 0,55A

Cable entriesEntries and threads ISO Nylon cable glands for non-armoured cableNickel chromed brass PE series cable glands for non- armoured cable Nickel chromed brass PEP cable glands for armoured cable with brass continuity plate on XBL-A

ComponentsDrilling on request Full range indicator lamp with LED Voltage of use 24V-254V AC/DCPush button (green, red, black, yellow or blue) 1 contact (3 contacts maximum)Emergency stop 1 contact (3 contacts maximum) Rotary switch 2 or 3 positions (2 contacts maximum) Anmeter Ex e: direct 1A or with CT/1Amp. max.

For Accessories see page 130

XBL: 122 x 120 x 91 (mm) XBL: 220 x 120 x 91 (mm)

1 Function 2 Functions Ammeter 3 Functions 4 Functions Ammeter

Type 21A 21FA 21VA 215A 215VA 22A 23A AMP 26A 38A 41A 43A 22AMP 38AMP

Push Button Green 1 NO ● – – – – ● ● – ● ● ● ● ● ●

Emergency Stop PB Push/Pull 1 NC – ● – – – – – – ● – – – – –

Emergency Stop PB Push/Pull 1 NC with Key 455 – – ● – – – – – – – – – – –

Switch 0-1, 2NO – – – ● – – – – – ● – – – ●

Switch with Key 0-1, 1 NO – – – – ● – – – – – – – – –

Push Button Red 1 NC – – – – – ● – – – ● ● ● ● ●

Green Indicator Lamp – – – – – – ● – ● – ● ● – –

Red Indicator Lamp – – – – – – – – – – – ● – –

Ammeter TC/IA Graduate – – – – – – – ● – – – – ● ●Scale 0-In-3In dilo IN= to be indicated

Front Plug – – – – – – – – – – – – ● –

*Add function to complete part number, e.g. XBL21A

**Second cablegland impossible

M6

M20 x 1,5M6

M6

M20 x 1,5M20 x 1,5

**Second cablegland impossible

M6M20 x 1,5

3 x ø22.5

XB300 / XBL15 XB400 / XBL25XB300 / XBL15with ammeter

XB400 / XBL25with ammeter

Visu 50x50

3x ø22.5

Visu 50x50 104

80

80

214

80

214

104

80

ø22.5

Standard Confi gurations

Thomas & Betts • www.tnb-hazardous.com

EJB Range 128 EVS Range 42 Exe Nylon Gland 166Stopping Plugs 164

Page 116: Catalog Thomas Betts

116

• Robust design and paint finish ideal for marine application

• Can be supplied complete with terminals and glands

so all on site combinations are covered

Approvals / Characteristics Features

Approved to: EN60079-0, 60079-1, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/EC LCIE 11 ATEX 3051X / IECEx LCI 11.0046XEx II 2 G / DEx e or ia or eia IIC T6, T5 or T4Ex tD A21 IP66 T85ºC, T100ºC to T135ºCT4: ≤ -20ºC to ≤ +90ºCT5: ≤ -20ºC to ≤ +55ºCT6: ≤ -20ºC to ≤ +40ºCLCIE 11 ATEX 3046 U / IECEx LCI 11.0043UEx e II Ex tD A21 IP66

Certifi cation & Standards

XB RangeInstrumentation boxes

Thomas & Betts • www.tnb-hazardous.com

Page 117: Catalog Thomas Betts

Maximum number of terminals

Dimensions (mm) size (in mm2) / In Max (in A) Weight in

Type Material A B C D E 2.5/21 4/28 6/36 10/50 16/66 35/109 70/167 70/95/100 120/234 185/307 240/350 (kg)

XB300 Alu 122 120 91 106 82 13 11 8 6 – – – – – – – 1.0

XB400 Alu 220 120 91 204 82 33 27 21 16 – – – – – – – 1.4

XB510 Alu 160 160 91 140 110 20 17 13 10 – – – – – – – 1.5

XB520 Alu 260 160 91 240 110 40 33 25 20 – – – – – – – 2.0

XB570 Alu 202 232 111 180 180 56 46 36 14 11 9 – – – – – 2.4

XB700 Alu 360 160 91 340 110 61 50 38 30 – – – – – – – 2.5

XB710 Alu 330 230 111 310 180 108 90 68 54 22 17 15 – – – – 3.4

XB750 Alu 403 312 141 382 262 204 171 129 51 42 21 16 – – – – 6.7

XB950 Alu 600 230 111 580 260 216 180 134 54 45 33 – 19 6 5 5 7.0

XB960 Alu 600 600 202 555 525 432 360 204 162 135 132 39 20 11 9 9 26.0

EJB Range 128 EVS Range 42 Exe Nylon Gland 166

Ex Boxes & Enclosures - XB Range

Technical Specifi cations

117

Related Products

EnclosureAluminium ALSi 12, yellow polyurethane paintRAL 1003 (other colours available on request)Stainless steel unlosable screwsOptional hingesRated voltagesDependent on the components fi tted in the box (eg:with terminal block: Un max = 500V)

Cable entriesISO entries and threadsNylon cable glands for non-armoured cableNickel chromed brass cable glands for non-armoured cableNickel chromed brass PE series cable glands for armoured cable PEP series with brass continuity plate on XBL

Terminal block Equipment of the terminal lock wire any type of certifi ed Exe or Exia terminals. The maximum number of terminal blocks per box is dependent on the certifi cationStainless steel external earthOther options available upon request

Dimensions

Stopping Plugs 164

For mounting ø 06.5

Thomas & Betts • www.tnb-hazardous.com

For full details and design service contact Sales

Page 118: Catalog Thomas Betts

• Wide variety of sizes and functions available as standard products for speed of supply and custom

built to meet the end users exact requirements• All manufactured with approved components allowing

peace of mind• Manufactured from aluminium ideal for marine applications

Approvals / Characteristics Features

118

XB-A RangeStandard control boxes

Certifi cation & StandardsApproved to: EN60079-0, 60079-1, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/EC LCIE 11 ATEX 3051X / IECEx LCI 11.0046XEx II 2 G / DEx de or e or ia or eia IIC T6, T5 or T4Ex tD A21 IP66 T85ºC, T100ºC to T135ºCT4: ≤ -20ºC to ≤ +90ºCT5: ≤ -20ºC to ≤ +55ºCT6: ≤ -20ºC to ≤ +40ºC

Thomas & Betts • www.tnb-hazardous.com

Page 119: Catalog Thomas Betts

Exe Nylon Gland 166

Ex Boxes & Enclosures - XB-A Range

Technical Specifi cations

119

Related Products

EnclosureXB-A: Aluminium ALSi 12, yellow polyurethane paint RAL1003 (other colours on request)Stainless steel unlosable screws Optional hingesProtection class: ITechnical CharacteristicsAC: U = 415V max. I = 1,75A or U = 240V, I = 3A orU = 120V, I = 6A DC: U = 415V max. I = 0,165A or U = 250V, I = 0,27A or U = 125V, I = 0,55A

Cable entriesEntries and threads ISO Nylon cable glands for non-armoured cableNickel chromed brass PE series cable glands for non- armoured cable Nickel chromed brass PEP cable glands for armoured cable with brass continuity plate on XBL-A

ComponentsDrilling on request Full range indicator lamp with LED Voltage of use 24V-254V AC/DCPush button (green, red, black, yellow or blue) 1 contact (3 contacts maximum)Emergency stop 1 contact (3 contacts maximum) Rotary switch 2 or 3 positions (2 contacts maximum) Anmeter Ex e: direct 1A or with CT/1Amp. max.

Dimensions

Stopping Plugs 164EJB Range 128 EVS Range 42

Standard Confi gurations

XB: 122 x 120 x 91 (mm) XB: 220 x 120 x 91 (mm)

1 Function 2 Functions Ammeter 3 Functions 4 Functions Ammeter

Type 21A 21FA 21VA 215A 215VA 22A 23A AMP 26A 38A 41A 43A 22AMP 38AMP

Push Button Green 1 NO ● – – – – ● ● – ● ● ● ● ● ●

Emergency Stop PB Push/Pull 1 NC – ● – – – – – – ● – – – – –

Emergency Stop PB Push/Pull 1 NC with Key 455 – – ● – – – – – – – – – – –

Switch 0-1, 2NO – – – ● – – – – – ● – – – ●

Switch with Key 0-1, 1NO – – – – ● – – – – – – – – –

Push Button Red 1 NC – – – – – ● – – – ● ● ● ● ●

Green Indicator Lamp – – – – – – ● – ● – ● ● – –

Red Indicator Lamp – – – – – – – – – – – ● – –

Ammeter TC/IA Graduate – – – – – – – ● – – – – ● ●Scale 0-In-3In dilo IN= to be indicated

Front Plug – – – – – – – – – – – – ● –

*Add function to complete part number, e.g. XBL21A

**Second cablegland impossible

M6

M20 x 1,5M6

M6

M20 x 1,5M20 x 1,5

**Second cablegland impossible

M6M20 x 1,5

3 x ø22.5

XB300 / XBL15 XB400 / XBL25XB300 / XBL15with ammeter

XB400 / XBL25with ammeter

Visu 50x50

3x ø22.5

Visu 50x50 104

80

80

214

80

214

104

80

ø22.5

Thomas & Betts • www.tnb-hazardous.com

For Accessories see page 130

Page 120: Catalog Thomas Betts

• Robust design• Manufactured from stainless steel 316 so ideal for offshore applications• Can be supplied complete with terminals and glands so all on site combinations are covered

Approvals / Characteristics Features

120

XBi RangeInstrumentation boxes

Certifi cation & StandardsApproved to: EN60079-0, 60079-1, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/EC LCIE 11 ATEX 3050X / IECEx LCI 11.0044XEx II 2 G / DEx e or ia or eia IIC T6, T5 or T4Ex tD A21 IP66 T85ºC, T100ºC or T135ºCT4: ≤ -20ºC to ≤ +90ºCT5: ≤ -20ºC to ≤ +55ºCT6: ≤ -20ºC to ≤ +40ºCLCIE 11 ATEX 3045 U / IECEx LCI 11.0041UEx e IIEx tD A21 IP66

Thomas & Betts • www.tnb-hazardous.com

Page 121: Catalog Thomas Betts

Maximum number of terminals

Dimensions (mm) size (in mm2) / In Max (in A) Weight in

Type Material A B C D E 2.5/21 4/28 6/36 10/50 16/66 35/109 70/167 70/95/100 120/234 185/307 240/350 (kg)

XBi100 Inox 100 100 61 60 60 9 (Min) 8 (Min) – – – – – – – – – 0.8

XBi150 Inox 150 150 81 110 110 19 16 12 10 – – – – – – – 0.4

XBi200 Inox 200 100 61 160 110 29 (Min) 24 (Min) – – – – – – – – – 1.1

XBi300 Inox 300 200 81 260 160 98 80 60 25 – – – – – – – 2.2

XBi400 Inox 400 300 161 360 260 138 116 86 70 56 21 17 – – – – 5.6

XBi500 Inox 500 400 161 460 360 356 296 224 135 87 46 14 11 – – – 3.7

XBi600 Inox 600 200 121 560 360 218 182 136 55 45 34 – – – – – 4.8

Exe Nylon Gland 166

Ex Boxes & Enclosures - XBi Range

Technical Specifi cations

121

Related Products

Dimensions

Stopping Plugs 164

Enclosure316L stainless steel,1.25mm thickStainless steel unlosable screwsOptional hinges

Rated voltagesDependent on the components fi tted in the box (eg:with terminal block: Un max = 500V)Cable entriesISO entries and threadsNylon cable glands for non-armoured cableNickel chromed brass cable glands for non-armoured cableNickel chromed brass PE series cable glands for armoured cable PEP series with brass continuity plate on XBL

Terminal block Equipment of the terminal lock wire any type of certifi ed Exe or Exia terminals. The maximum number of terminal blocks per box isdependent on the certifi cationStainless steel external earthOther options available upon request

A

D

E B

C

EJB Range 128 EVS Range 42

Thomas & Betts • www.tnb-hazardous.com

For full details and design service contact Sales

Page 122: Catalog Thomas Betts

• Robust design• Manufactured from stainless steel 316 so ideal for offshore applications• Can be supplied complete with terminals and glands so all onsite combinations are covered

Approvals / Characteristics Features

122

XBi-A RangeStandard control boxes

Certifi cation & StandardsApproved to: EN60079-0, 60079-1, 60079-7, 60079-11, EN61241-0, 61241-1EC TYPE Examination Certificate: Under 94/9/EC LCIE 11 ATEX 3050 / IECEx LCI 11.0044Ex II 2 G / DEx de or e or ia or eia IIC T6, T5 or T4Ex tD A21 IP66 T85ºC, T100ºC or T135ºCEx de IIC T6, T5 or T4 IP66T4: ≤ -20ºC to ≤ +90ºCT5: ≤ -20ºC to ≤ +55ºCT6: ≤ -20ºC to ≤ +40ºCGlow wire test: 960°C EN60598-2-22

Thomas & Betts • www.tnb-hazardous.com

Page 123: Catalog Thomas Betts

EJB Range 128 EVS Range 42 Exe Nylon Gland 166

Ex Boxes & Enclosures - XBi-A Range

Technical Specifi cations

123

Related Products

Dimensions

Stopping Plugs 164

EnclosureXBi-A (upon request): 316L stainless steel, 1.25mm thickStainless steel unlosable screwsProtection class: ITechnical CharacteristicsAC: U = 415V max. I = 1,75A or U = 240V, I = 3A orU = 120V, I = 6A DC: U = 415V max. I = 0,165A or U = 250V, I = 0,27A or U = 125V, I = 0,55A

Cable entriesEntries and threads ISO Nylon cable glands for non-armoured cableNickel chromed brass PE series cable glands for non- armoured cable Nickel chromed brass PEP cable glands for armoured cable with brass continuity plate on XBL-A

ComponentsDrilling on request Full range indicator lamp with LED Voltage of use 24V-254V AC/DCPush button (green, red, black, yellow or blue) 1 contact (3 contacts maximum)Emergency stop 1 contact (3 contacts maximum) Rotary switch 2 or 3 positions (2 contacts maximum) Anmeter Ex e: direct 1A or with CT/1Amp. max.

60

60 160

4x

3x ø22.5

Label

XBi100 XBi200

ø20.5

ø22.5 ø20.560

Standard Confi gurations

XBi: 100 x 100 x 61 (mm) XBi: 200 x 100 x 61 (mm)

1 Function 2 Functions 3 Functions 4 Functions

Type 21A 21FA 21VA 215A 215VA 22A 23A 26A 38A 41A 43A

Push Button Green 1 NO ● – – – – ● ● ● ● ● ●

Emergency Stop PB Push/Pull 1NC – ● – – – – – ● – – –

Emergency Stop PB Push/Pull 1NC with Key 455 – – ● – – – – – – – –

Switch 0-1, 2NO – – – ● – – – – ● – –

Switch with Key 0-1, 1NO – – – – ● – – – – – –

Push Button Red 1 NC – – – – – ● – – ● ● ●

Green Indicator Lamp – – – – – – ● ● – ● ●

Red Indicator Lamp – – – – – – – – – – ●

Ammeter TC/IA Graduate – – – – – – – – – – –Scale 0-In-3In dilo IN= to be indicated

Front Plug – – – – – – – – – – –

*Add function to complete part number, e.g. XBL21A

Thomas & Betts • www.tnb-hazardous.com

For Accessories see page 130

Page 124: Catalog Thomas Betts

• External mounting points allowing for junction boxes to be mounted without the need for the removal of the lid• Robust design in cast aluminium• Supplied complete with terminals and glands so onsite combinations are covered

Approvals / Characteristics Features

124

GUV RangeAluminium junction boxes

Approved to: EN60079-0, 60079-1EC TYPE Examination Certificate:LCIE 00 ATEX 6022 / IECEx in progressEx II 2 GEx d IIC T6 to T4LCIE 00 ATEX 6022T6: ≤ -20°C to ≤ +40°CT5: ≤ -20°C to ≤ +55°CT4: ≤ -20°C to ≤ +60°C

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 125: Catalog Thomas Betts

EXL Conduit 142 XFF Range 28

Ex Boxes & Enclosures - GUV Range

Technical Specifi cations

125

Related Products

EnclosureAluminium alloy body EN 1706 AC - 43100KF - AISI 10MgYellow polyurethane paint RAL1003Stainless steel screws

Cable entriesStandard:Two to four 3/4” NPT entries, accordingto modelOptions: 1” NPT entry on GUV36Metric entries upon request

TerminalsGUV26: 4 terminals up to 6mm2 supplied on request4 interconnected earthing terminals (M4 clampingscrews) (1 terminal per earth)GUV36: terminals supplied on request, maximumnumber 8 x 25mm2 terminals or 6 x 35mm2

terminals

Dimensions

Stopping Plugs 164

Type Number of entries Number of terminals (optional) Weight (Kg)

GUVC26-00000 2 -c- 4 x 2.5 to 6mm2 0.6

GUVC36-00000 2 -c- Max 8 x 25mm2 or 6 x 35mm2 1.6

GUVL26-00000 2 i- 4 x 2.5 to 6mm2 0.6

GUVL36-00000 2 i- Max 8 x 25mm2 or 6 x 35mm2 1.6

GUVT26-00000 3 T 4 x 2.5 to 6mm2 0.6

GUVT36-00000 3 T Max 8 x 25mm2 or 6 x 35mm2 1.7

GUVX26-00000 4 X 4 x 2.5 to 6mm2 0.7

GUVX36-00000 4 X Max 8 x 25mm2 or 6 x 35mm2 1.8

Thomas & Betts • www.tnb-hazardous.com

PA Gland 152

Page 126: Catalog Thomas Betts

• Ex d approved allowing it to be used in more

sensitive applications

• Manufactured from cast aluminium and machined to

ensure flame paths are correct

Approvals / Characteristics Features

126

EFDC / SRC / XMC RangeControl stations

Certifi cation & StandardsApproved to: EN60079-0, 60079-1EC TYPE Examination Certificate:LCIE 00 ATEX 6022 / IECEx in progressEx II 2 GEx d IIC T6 to T4Type (without light): EFDC, SRCT6: ≤ -20°C to ≤ +40°CT5: ≤ -20°C to ≤ +55°CT4: ≤ -20°C to ≤ +60°CType (with light): EFDC, SRCT6: ≤ -20°C to ≤ +40°C

Thomas & Betts • www.tnb-hazardous.com

Page 127: Catalog Thomas Betts

SRC / EFDC(enclosure size 1)

SRC / EFDC(enclosure size 2)

XMC 36(enclosure size 3)

166137

140

3/4343/4

3/4

ø6.5

ø765

23

195

124112

105

3/4

3/4

58

150

M6M6

Type SRC Rotary Switch Unit 215 415 330 340 215V

16A 2NO ● – – – ●

32A 3NO Lockable – – ● – –

40A 3NO Lockable – – – ● –

With Key 455 – – – – ●

16A 4 NO – ● – – –

EXL Conduit 142

Ex Boxes & Enclosures - EFDC / SRC / XMC Range

Technical Specifi cations

127

Related Products

EnclosureBody in marine grade aluminium alloyEN1706 AC - 43100KF - AISI 10MgPolyurethane paint: yellow RAL1003 except EFDC21G (red paint RAL3001)Stainless steel screwsPower supplyMaximum operating power: 400 Vac max for the indicator lamps6 A max for the push buttons40 A max for the rotary switchesFor indicator and potentiometer: please enquire

Cable entriesStandard: Two 3/4”NPT one being equipped with onezinc chromed steel plugOption:T wo 1” NPT (or ISO M32) on control stationssizes 2 and 3Recommendation: For Zone I and explosion proof IIC Compound cable gland is required

Terminal blockDirect connection to the component

Dimensions

For Accessories see page 130

Stopping Plugs 164 PA Gland 152 XFF Range 28

Type EFDC 21 25 41 43 44 22 40 42 38 23 21F 21V 21G 21P 24 23A 39 37 36

Green Push Button NO+NC ● – ● ● ● ● ● – ● ● – – – – – – – – –

2 x Green Push button NO+NF – – – – – – – ● – – – – – – – – – – –

Push/Pull Emergency Button NO+NF – ● – – – – – – – – ● – – – – – – – –

Emergency Key Operated Push Button 455 NO+NF – – – – – – – – – – – ● – – – – – – –

Break Glass Automatic Cut-off NO+NC – – – – – – – – – – – – ● – – – – – –

Potentiometer Driver – – – – – – – – – – – – – ● – – – – –

Green Indicator Light – ● ● ● ● – – – – ● – – – – ● ● ● ● –

Push Button Red NO+NC – – ● ● ● ● ● – ● – – – – – – – – – –

2 x Push Button Red NO+NC – – – – – – – ● – – – – – – – – – – –

Indicator Light Red 230V – – – ● – – – – – – – – – – – ● ● – –

Push Button Black NO+NC – – – – ● – ● – – – – – – – – – – – –

Rotary Switch Unit 2x16A – – – – – – – – ● – – – – – – – ● ● –

2 x Rotary Switch Unit 2x16A – – – – – – – – – – – – – – – – – – ●

Type XMC

XMC36 1 display diameter 80 with base plate - no equipment

*Add function to complete part number, e.g. EDFC21, SRC215, XMC36

Thomas & Betts • www.tnb-hazardous.com

Page 128: Catalog Thomas Betts

• Robust construction

• Wide variety of sizes

• Large choice of electrical components

• Customised to user’s specification

Approvals / Characteristics Features

128

EJB RangeCustom built panels

Approved to: EN60079-0, 60079-1EC TYPE Examination Certificate:INERIS 11 ATEX 0050XEx II 2 GEx d IIB T5 or T6 GbEx II 2 (1) GEx d (ia IIC Ga, or ib, or ib IIC, or ia Ga) IIB T6 GbSafe operating temperature range: -20ºC to +40ºCIECEx Summer 2012: Contact Sales for more information onZones 21 and 22

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 129: Catalog Thomas Betts

EXL Conduit 142 GUV Range 124

Ex Boxes & Enclosures - EJB Range

Technical Specifi cations

129

Related Products

EnclosureMarine grade aluminium alloy type EN 1706 AC - 43100KF - AISI 10Mg Yellow polyurethane paint RAL1003 (alternatives on request) Stainless steel external earth Stainless steel screws Hinged door if command buttons are on the panel (except EJB0)Cable entriesNPT or ISO entries and threads as requested Brass, nickel chromed brass or stainless steel cable gland for non armoured cableBrass, nickel chromed brass or stainless steel cable gland for armoured cableRecommendation: For Zone I and explosion group IIB Compound cable gland is required (except EJB0)

Switches and IndicatorsOn request Rotary switches: 1 to X positions two-way, spring return, layout on request (eg : 3NO + 1NC, 1 NO / Position...) Push buttons: Colours: green, red, black, yellow, blue Mechanical reactivation Contacts: maximum 6 contacts as specifi ed, NO or NC Indicator lamps: Colours: green, red, white, yellow, blue, power supply not exceeding 400V LEDs Potentiometer: please advise: value in Ohms, power in W, Number of turns, linear or logarithmic For all components: legends as requested Isolating switch/circuit-breaker: up to 800A Meters behind visual display: ammeter, voltmeter or others upon request

Fixing4 threaded holes on the back plate (see table) Frame or supporting feet on request

Dimensions

For Accessories see page 130

Stopping Plugs 162

GxH

External Internal Fixing / Mounting Internal Plate

Type A B C D E F G H L (mm) Weight (kg)

EJB0 200 145 130 145 90 90 140 85 M6 138 x 85 4

EJB1 302 190 170 225 115 130 200 100 M6 215 x 110 8

EJB2 295 230 165 225 165 132 185 130 M6 220 x 160 9

EJB4 410 300 167 340 220 127 290 190 M8 320 x 210 16

EJB5 475 295 220 390 207 179 335 178 M8 380 x 200 18

EJB8 625 360 250 525 260 195 480 210 M8 510 x 250 33

EJB11 595 505 275 485 395 207 436 335 M10 470 x 380 55

EJB12 805 435 315 690 345 246 605 262 M12 675 x 325 75

EJB13 832 612 323 720 435 252 628 405 M12 790 x 470 92

PA Gland 152

Thomas & Betts • www.tnb-hazardous.com

Page 130: Catalog Thomas Betts

Box Accessories

130

Complete Units for DTS control stations and boxes

(SRC - EFDC Mod 1 & 2 or EJB as specified)

Type Function

BPN10 Push button Black NO+NC

BPR10 Push button Red NO+NC

BPV10 Push button green NO+NC

REA20 Reset button (customised for EJB ranges)

BCP30 Simple emergency stop push button NO+NC

BCP40 Push/Pull button Emergency Stop NO+NC

BCP50 Push button, unlockable by key N° 455

PRC10 Rotary switch 2x16A 0-1 2NO

PRC20 Rotary switch operated by key No 455 2x 16A 0-1 2NO

PRC30 Rotary switch 2x16A 1-2 NO+NC

PRC40 Rotary switch 2x16A 1-0-2 NO-0-NC

PRC50 Rotary switch 2x16A 0-1-2-0-NO-NO

PRC60 Rotary switch 4x16A 0-1 4NO

PRC70 Lockable rotary switch 3x25A 3NO

VAV10 Indicator lamp 230V - Green

VAR10 Indicator lamp 230V - Red

VAC10 Indicator lamp 230V - White

VAJ10 Indicator lamp 230V - Yellow

VAB10 Indicator lamp 230V - Blue

OptionsRotary Switch Options:- Spring return (40A max for SRC) - Confi guration on request (eg : 3NO+1NF, 1 NO/Position...)Push button options:- Colours: Green, Red, Black,Amber, Blue- Contacts (model 1 & EJB):Max 3 contacts according to request NO or NC - Contacts (model 2): Max 6 contacts according to request NO or NCIndicator Lamp Options:- Power supply up to 400V- LEDFor all products:Legends as requested

Spare Components for Control Panels & Enclosures

Components for Control Station

Spare Parts for the complete units

(EFDC / SRC or EJB as specified)

Type Function

BP01 Contacts NO+NC for push button switches

PR01 Rotary switch unit 2x16A 0-1 2NO

PR02 Rotary switch unit 2x16A 1-2 NO+NC

PR03 Rotary switch unit 2x16A 1-0-2 NO-0-NC

PR04 Rotary switch unit 2x16A 0-1-2-0-NO-NO

PR05 Rotary switch unit 4x16A 0-1 4NO

PR06 Rotary switch unit 3x25A 0-1 3NO

PR07 Rotary switch top

PR07V Key operated switch top

BP02 Cap for push switch Green

BP03 Cap for push switch Red

BP04 Cap for push switch Black

BP05 Cap for mushroom push/pull switch

BP05V Cap for key operated mushroom push switch

DE01 Indicator lamp lens Green

DE02 Indicator lamp lens Red

DE03 Indicator lamp lensWhite

DE04 Indicator lamp lens Amber

DE05 Indicator lamp lens Blue

DE10 Lamp holder for BA9S lamp

OptionsRotary Switch Options:- Spring return (40A max for SRC) - Confi guration on request (eg : 3NO+1NF, 1 NO/Position...)

For all products:- Legends as requested

Thomas & Betts • www.tnb-hazardous.com

Page 131: Catalog Thomas Betts

Accessories & Spare Parts

131

Polyester / Aluminium Plug & Socket (Safe Disconnect)

DPX / DRX/ RPX / PPX Range

Socket Plug Nominal Power Cable Dimensions (mm) Weight (kg)

Type DRX Type DPX Poles Current (A) Supply (V) Gland A B ø C D E F G ø d AI A0 BI B0 Y Socket Plug

116E250 116E250 IP+N+PE 20 200/250 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

216X24 216X24 2P 20 24 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

216E24 216E24 2P+PE 20 24 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

216E250 216E250 2P+PE 20 200/250 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

216E415 216E415 2P+PE 20 380/450 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

316E250 316E250 3P+PE 20 200/250 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

316E415 316E415 3P+PE 20 380/450 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

416E250 416E250 3P+N+PE 20 200/250 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

416E415 416E415 3P+N+PE 20 380/450 M20 125 58 8-13 127 131 68 90 78 4.5 204 215 162 168 180 0.3 0.16

132E250 132E250 IP+N+PE 32 200/250 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

232X24 232X24 2P 32 24 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

232E24 232E24 2P+PE 32 24 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

232E250 232E250 2P+PE 32 200/250 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

232E415 232E415 2P+PE 32 380/450 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

332E250 332E250 3P+PE 32 200/250 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

332E415 332E415 3P+PE 32 380/450 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

432E250 432E250 3P+N+PE 32 200/250 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

432E415 432E415 3P+N+PE 32 380/450 M25 145 68 13-19 138 132 84 107 70 6 214 229 162 171 200 0.46 0.24

163E250 163E250 IP+N+PE 63 200/250 M32 152 83 17-25 165 162 89 122 88 6.5 233 259 184 199 236 0.64 0.42

263X24 263X24 2P 63 24 M32 152 83 17-25 165 162 89 122 88 6.5 233 259 184 199 236 0.64 0.42

363E415 363E415 3P+PE 63 380/450 M32 152 83 17-25 165 162 89 122 88 6.5 233 259 184 199 236 0.64 0.42

463E415 463E415 3P+N+PE 63 380/450 M32 152 83 17-25 165 162 89 122 88 6.5 233 259 184 199 236 0.64 0.42

Plug

Wall socket (30°)

Wall socket RPX Fitting plugged in to/unplugged from wall socket (30°)

D

CØ d

E

G

B

A

ø

Socket Plug Nominal Power Cable DImensions (mm) Weight (kg)

Type RPX Type PPX Poles Current (A) Supply (V) Gland A B ø C D E F G ø d AI A0 BI B0 Y Socket Plug

1125E250 1125E250 IP+N+T 125 200/250 M50 220 146 27-41 378 175 221 – 174 9.5 513 – 175 – – 8.0 2.6

3125E415 3125E415 3P+T 125 380/450 M50 220 146 27-41 378 175 221 – 174 9.5 513 – 175 – – 8.0 2.6

4125E415 4125E415 3P+N+T 125 380/450 M50 220 146 27-41 378 175 221 – 174 9.5 513 – 175 – – 8.0 2.6

Approved to: IEC 60079-0, 60079-1, 60079-7, 61241-0, 61241-1 60309-1, 60309-4EC TYPE Examination Certificate: under new directive 94/9/EC20A versions: LCIE 99 ATEX 6027X, IECEx LCI09.005X, ≤ -40°C to ≤ +60°C T5 T90ºC, ≤ -40°C to ≤ +40°C T6 T70ºC32A versions: LCIE 05 ATEX 6149, IECEx LCI09.0006, ≤ -40°C to ≤ +60°C T4 T98ºC, ≤ -40°C to ≤ +40°C T6 T78ºC63A versions: LCIE 05 ATEX 6150, IECEx LCI09.0007, ≤ -40°C to ≤ +60°C T4 T107ºC, ≤ -40°C to ≤ +40°C T5 T87ºC125A versions: LCIE 04 ATEX 6038, IECEx LCI09.0015, ≤ -40°C to ≤ +60°C T5 T90ºC, ≤ -40°C to ≤ +50°C T6 T80ºCATEX II 2 G / D, IP6x Exd e II C tDA21 Ingress protection: IP66/67 (PBT), IP65 (aluminium)

Thomas & Betts • www.tnb-hazardous.com

Page 132: Catalog Thomas Betts

26132

Thomas & Betts • www.tnb-hazardous.com

Conduit Systems

Page 133: Catalog Thomas Betts

Conduit Systems

133

Thomas & Betts • www.tnb-hazardous.com

Page 134: Catalog Thomas Betts

134

Conduit / Fitting Range

Conduit Fittings - Selection Guide

Thomas & Betts • www.tnb-hazardous.com

EXBB BraidNylon Conduit Page 136

Group 1 Gland Page 144

Group 1 90ºElbow Gland Page 144

EXB Nylon Conduit Page 136

Group 1 Universal Swivel Fitting Page 148

Group IIGland Page 146

Group 1 Univeral Fitting Page 148

XP Flex Page 156

Prot

ectio

n Ty

peG

asG

roup

Dus

tG

roup

Zo

nes

1DIV

2DIVI

2DIV

1DIV

For use with Liquid Tight Conduits

Page 135: Catalog Thomas Betts

Conduit Fittings - Selection Guide

135

Thomas & Betts • www.tnb-hazardous.com

Standard Stopping Plugs Page 162

TamperproofStopping Plugs Page 162

Hex HeadStoppingPlugs Page 164

Thread Convertors Page 158

Nylon StoppingPlugs Page 164

Coupler Page 166

Dome HeadStopping Plugs Page 164

Page 136: Catalog Thomas Betts

• Anti-static Nylon conduit

• Approved for use in Ex e applications for

Zones 1, 2, 21 & 22

Approvals / Characteristics Features

136

EXB / EXBB RangeNon-metallic nylon conduit

EC TYPE Examination Certificate:ATEX: Baseefa 08 ATEX 0003XIECEx: IECEx BAS08.0001XGOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0091Temperature: -20°C to 80ºCRTI 110ºC to EN60079-0Special Characteristics: EXB: Surface resistivity 106ΩEXBB: Screening level 60dB at 1MHz

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 137: Catalog Thomas Betts

EXPQM Fitting 140

Non-Metallic Nylon Conduit - EXB / EXBB Range

Technical Specifi cations

137

Related Products

For Accessories see page 166

EXBQM Fitting 140

British Conduit Size (mm) 16 20 28 34 42 54

Coil Lengths (m) 10/30/50 10/30/50 10/30/50 10/30/50 10/30/50 10/30/50

Minimum Bore (mm) 11.15 16.45 21.5 27.5 35.2 46.2

Type Outside Diameter (mm) 16.5 21.20 28.35 34.5 42.4 54.3

Anti-Static Nylon 12 (Stainless Steel) EXBB03* EXBB04* EXBB05* EXBB06* EXBB07* EXBB08*

*Add coil length to complete part number, e.g. 10 metres = EXBB0510

British Conduit Size (mm) 16 20 28 34 42 54

Coil Lengths (m) 10/30/50 10/30/50 10/30/50 10/30/50 10/30/50 10/30/50

Minimum Bore (mm) 11.15 16.45 21.5 27.5 35.2 46.2

Type Outside Diameter (mm) 16.5 21.20 28.35 34.5 42.4 54.3

Anti-Static Nylon 12 (Black) EXB03* EXB04* EXB05* EXB06* EXB07* EXB08*

*Add coil length to complete part number, e.g. 10 metres = EXB0510

EXB Anti-Static Conduit

EXBB Overbraided Conduit

Thomas & Betts • www.tnb-hazardous.com

Page 138: Catalog Thomas Betts

• Manufactured in Nickel Plated Brass

• Approved for use in Ex e applications for

Zones 1, 2, 21 & 22

Approvals / Characteristics Features

138

EXBQM / EXPQA RangeNylon conduit fi ttings

EC TYPE Examination Certificate:ATEX: Baseefa 08 ATEX 0003XIECEx: IECEx BAS08.0001XGOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0091Temperature: -20°C to 80ºC

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 139: Catalog Thomas Betts

EXPQM Straight Male Conduit Fitting

Non-Metallic Nylon Fittings - EXPQM / EXBQA Range

Technical Specifi cations

139

Related Products

For Accessories see page 166

British Conduit Size (mm) 16 20 28 34 42 54

Metric Thread Size (mm) 20 20 25 32 40 50

Type NPT Thread Size (inch) 1/2 1/2 3/4 1 11/4 11/2

Metric - Nickel Plated Brass EXPQM0304 EXPQM0404 EXPQM0505 EXPQM0606 EXPQM0707 EXPQM0808

NPT Thread - Nickel Plated Brass EXPQA0304 EXPQA0404 EXPQA5305 EXPQA0606 EXPQA0707 EXPQA0808

*For use with EXB Nylon Conduit see pages 140-141

British Conduit Size (mm) 16 20 28 34 42 54

Metric Thread Size (mm) 20 20 25 32 40 50

Type NPT Thread Size (inch) 1/2 1/2 3/4 1 11/4 11/2

Metric - Nickel Plated Brass EXBQM0304 EXBQM0404 EXBQM0505 EXBQM0606 EXBQM0707 EXBQM0808

NPT Thread - Nickel Plated Brass EXBQA0304 EXBQA0404 EXBQA5305 EXBQA0606 EXBQA0707 EXBQA0808

*For use with EXBB Nylon Conduit see pages 140-141

EXBQM Straight Male Conduit Fitting

Locknuts 166 Sealing 166Washers

EXB Range 138 EXBB Range 138

Thomas & Betts • www.tnb-hazardous.com

Page 140: Catalog Thomas Betts

140

General Oil Resistant - Galzanised Steel Core with a general purpose oil resistant coating

Low Fire Hazard - Galzanised Steel Core with a LFH coating

Certification Standard: IEC 61386Static Temp: -25°C to +105°CFlexing Temp: -5°C to +105°C

Special Characteristics: Flame retardant PVC covering

Flame Propogation:

Flame dies in less than 30 seconds after ignition source

is removed

Certifi cation & Characteristics

Certification Standard: IEC 61386 LUL Fully Compliant (E1042A6)MOD to NES 518: Issue 3 DEF STAN 61-12 (Part 31) Issue 1

Static Temp: -25°C to +90°CFlexing Temp: -5°C to +90°CSpecial Characteristics: Limited Fire Hazard, zero halogen (BS6425 Pt 1)

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Certifi cation & Characteristics

High Temperature - Galvanised Steel Core with a high temperature resistant coating

Low Fire Hazard with EMC Protection - Galvanised Steel Core with a galvanised steel EMC shield and LFH Covering

Certification Standard: IEC 61386Static Temp: -50°C to +130°CFlexing Temp: -5°C to +90°C

Special Characteristics: Flame resistance: UL94 V2Chemical and oil resistant

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Certifi cation & Characteristics

Certifi cation & Characteristics

High Temperature Highly Flexible - Galvanised Steel Core with a high temperature, highly fl exible coating

Certification Standard: IEC 61386Static Temp: -65°C to +150°CFlexing Temp: -45°C to +135°C

Special Characteristics: High FlexibilityHigh Temperature

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Certifi cation & Characteristics

Certification Standard: IEC 61386MOD to NES 518: Issue 3 DEF STAN 61-12 (Part 31) Issue 1 Static Temp: -25°C to +90°C

Flexing Temp: -5°C to +90°CSpecial Characteristics: Limited Fire Hazard coveringEMC Screening level: 60db at 1MHz Braided

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Thomas & Betts • www.tnb-hazardous.com

Page 141: Catalog Thomas Betts

Liquid Tight Conduit - EXLB / EXLT / EXLH / EXBBT / EXLHC Range

141

Related Products

Universal 150Gland

90º Elbow 146Gland

Group II 148Gland

Group I & II 146Gland

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

General Oil Resistant (Black) EXLB03* EXLB04* EXLB05* EXLB06* EXLB07* EXLB08* EXLB09*

*Add coil length to complete part number, e.g. 10 metres = EXLB0510

Technical Specifi cations

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

Low Fire Hazard with EMC (Black) EXBBT03* EXBBT04* EXBBT05* EXBBT06* EXBBT07* EXBBT08* EXBBT09*

*Add coil length to complete part number, e.g. 10 metres = EXBBT0510

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

Low Fire Hazard (Black) EXLT03* EXLT04* EXLT05* EXLT06* EXLT07* EXLT08* EXLT09*

*Add coil length to complete part number, e.g. 10 metres = EXLT0510

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

High Temperature Highly Flexible (Black) EXLHC03* EXLHC04* EXLHC05* EXLHC06* EXLHC07* EXLHC08* EXLHC09*

*Add coil length to complete part number, e.g. 10 metres = EXLHC0510

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

High Temperature (Black) EXLH03* EXLH04* EXLH05* EXLH06* EXLH07* - -

High Temperature (Blue) EXLLH03* EXLLH04* EXLLH05* EXLLH06* EXLLH07* - -

*Add coil length to complete part number, e.g. 10 metres = EXLH0510

Thomas & Betts • www.tnb-hazardous.com

Page 142: Catalog Thomas Betts

142

General Oil Resistant - Stainless Steel 316 Core with a general purpose oil resistant coating

Low Fire Hazard - Stainless Steel Core with a LFH coating

Certification Standard: IEC 61386Static Temp: -25°C to +105°CFlexing Temp: -5°C to +105°C

Special Characteristics: Flame retardant PVC covering

Flame Propogation:

Flame dies in less than 30 seconds after ignition source

is removed

Certifi cation & Characteristics

Certification Standard: IEC 61386 LUL Fully Compliant (E1042A6)MOD to NES 518: Issue 3 DEF STAN 61-12 (Part 31) Issue 1

Static Temp: -25°C to +90°CFlexing Temp: -5°C to +90°CSpecial Characteristics: Limited Fire Hazard, zero halogen (BS6425 Pt 1)

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Certifi cation & Characteristics

High Temperature - Stainless Steel Core with a high temperature resistant coating

Low Fire Hazard with EMC Protection - Stainless Steel Core with a galvanised steel EMC shield and LFH Covering

Certification Standard: IEC 61386Static Temp: -50°C to +130°CFlexing Temp: -5°C to +130°C

Special Characteristics: Flame resistance: UL94 V2Chemical and oil resistant

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Certifi cation & Characteristics

Certifi cation & Characteristics

High Temperature Highly Flexible - Stainless Steel Core with a high temperature, highly fl exible coating

Certification Standard: IEC 61386Static Temp: -65°C to +150°CFlexing Temp: -45°C to +135°C

Special Characteristics: High FlexibilityHigh Temperature

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Certifi cation & Characteristics

Certification Standard: IEC 61386, UL full compliantMOD to NES 518: Issue 3 DEF STAN 61-12 (Part 31) Issue 1 Static Temp: -25°C to +90°C

Flexing Temp: -5°C to +90°CSpecial Characteristics: Zero halogen (BS6425 pt1) Limited Fire Hazard covering EMC Screening level: 60db at 1MHz Braided

Flame Propogation:

Flame dies in less than 30 seconds after ignition source is removed

Thomas & Betts • www.tnb-hazardous.com

Page 143: Catalog Thomas Betts

Related Products

Universal 150Gland

90º Elbow 146Gland

Group II 148Gland

Group I & II 146Gland

Liquid Tight Conduit - EXSB / EXST / EXSH / EXSBBT / EXSHC Range

143

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

General Oil Resistant (Black) EXSB03* EXSB04* EXSB05* EXSB06* EXSB07* EXSB08* EXSB09*

*Add coil length to complete part number, e.g. 10 metres = EXLB0510

Technical Specifi cations

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

Low Fire Hazard with EMC (Black) EXSBBT03* EXSBBT04* EXSBBT05* EXSBBT06* EXSBBT07* EXSBBT08* EXSBBT09*

*Add coil length to complete part number, e.g. 10 metres = EXLBBT0510

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

Low Fire Hazard (Black) EXST03* EXST04* EXST05* EXST06* EXST07* EXST08* EXST09*

*Add coil length to complete part number, e.g. 10 metres = EXLT0510

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

High Temperature Highly Flexible (Black) EXSHC03* EXSHC04* EXSHC05* EXSHC06* EXSHC07* EXSHC08* EXSHC09*

*Add coil length to complete part number, e.g. 10 metres = EXLHC0510

British Conduit Size (mm) 16 20 25 32 40 50 63

US Trade Sizes (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Inside Diameter (mm) 12.5 16.0 21.0 26.4 35.3 40.4 51.6

Type Coil Lengths (m) 10/30 10/30 10/30 10/20 10/20 10/20 10/20

High Temperature (Black) EXSH03* EXSH04* EXSH05* EXSH06* EXSH07* - -

High Temperature (Blue) EXSLLH03* EXSLLH04* EXSLLH05* EXSLLH06* EXSLLH07* - -

*Add coil length to complete part number, e.g. 10 metres = EXLH0510

Thomas & Betts • www.tnb-hazardous.com

Page 144: Catalog Thomas Betts

• Constructed from either Brass or Stainless Steel

with an epoxy resin barrier the Group I Flameproof

Gland is a high specification product, ideal for all

hazardous area applications

Approvals / Characteristics Features

G1 Gland / 90º Elbow

Liquid tight hazardous area fl ameproof glands

EC TYPE Examination Certificate:ATEX: Sira 09 ATEX 1231XIECEx: IECEx SIR09.0103XCSA: CSA File No: 2310045GOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0339XEx de I MbEx de IIC GbEx tb IIIC DbClass I DIv 2 ABCDClass II Div 1 EFGTemperature: -60ºC to +130ºC

Certifi cation & Standards

144

1DIV

2DIV

I

Thomas & Betts • www.tnb-hazardous.com

Page 145: Catalog Thomas Betts

General Oil Resistant 140

High Temperature Conduit 142

Low Fire Flexible Conduit 142

Sealing 166Washers

145

Liquid Tight Hazardous Area Flameproof G1 Gland

British Conduit Size (mm) 16 20 25 32 40 50 63

Metric Thread Size (mm) 20 20 25 32 40 50 63

Type NPT Thread Size (inch) 1/2 1/2 3/4 1 11/4 11/2 2

Metric - Brass HAM0304E HAM0404E HAM0505E HAM0606E HAM0707E HAM0808E HAM0909E

Metric - Nickel Plated HAMM0304E HAMM0404E HAMM0505E HAMM0606E HAMM0707E HAMM0808E HAMM0909E

NPT Thread - Brass HAA0304E HAA0404E HAA0505E HAA0606E HAA0707E HAA0808E HAA0909E

NPT Thread - Nickel Plated HAAM0304E HAAM0404E HAAM0505E HAAM0606E HAAM0707E HAAM0808E HAAM0909E

See pages 140-143 for suitable conduits *Stainless Steel available but elbow is Nickel Plated Brass **Elbow supplied is for liquid tight conduit only

British Conduit Size (mm) 16 20 25 32 40 50 63

Metric Thread Size (mm) 20 20 25 32 40 50 63

Type NPT Thread Size (inch) 1/2 1/2 3/4 1 11/4 11/2 2

Metric - Brass HAM0304G1 HAM0404G1 HAM0505G1 HAM0606G1 HAM0707G1 HAM0808G1 HAM0909G1

Metric - Nickel Plated HAMM0304G1 HAMM0404G1 HAMM0505G1 HAMM0606G1 HAMM0707G1 HAMM0808G1 HAMM0909G1

Metric - Stainless Steel HAMS0304G1 HAMS0404G1 HAMS0505G1 HAMS0606G1 HAMS0707G1 HAMS0808G1 HAMS0909G1

NPT Thread - Brass HAA0304G1 HAA0404G1 HAA0505G1 HAA0606G1 HAA0707G1 HAA0808G1 HAA0909G1

NPT Thread - Nickel Plated HAAM0304G1 HAAM0404G1 HAAM0505G1 HAAM0606G1 HAAM0707G1 HAAM0808G1 HAAM0909G1

NPT Thread - Stainless Steel HAAS0304G1 HAAS0404G1 HAAS0505G1 HAAS0606G1 HAAS0707G1 HAAS0808G1 HAAS0909G1

See pages 140-143 for suitable conduits

Related Products

Technical Specifi cationsATEX Flameproof G1 Gland

ATEX Flameproof 90º Elbow Gland

For Accessories see page 166

Thomas & Betts • www.tnb-hazardous.com

Page 146: Catalog Thomas Betts

• Constructed from either Brass or Stainless Steel

with an epoxy resin barrier the Group II Flameproof

Gland is a high specification product, ideal for all

hazardous area applications

Approvals / Characteristics Features

Group II Gland

Liquid tight hazardous area fl ameproof gland

EC TYPE Examination Certificate:Baseefa 06 ATEX 0256XIECEx BAS06.0059XEx d IICEx e IIEx tD A21Temperature: -60ºC to +80ºC

Certifi cation & Standards

146

Thomas & Betts • www.tnb-hazardous.com

Page 147: Catalog Thomas Betts

147

Liquid Tight Hazardous Area Flameproof Group II Gland

British Conduit Size (mm) 16 20 25 32 40 50 63

Metric Thread Size (mm) 20 20 25 32 40 50 63

Type NPT Thread Size (inch) 1/2 1/2 3/4 1 11/4 11/2 2

Metric - Brass HAM0304 HAM0404 HAM0505 HAM0606 HAM0707 HAM0808 HAM0909

Metric - Nickel Plated HAMM0304 HAMM0404 HAMM0505 HAMM0606 HAMM0707 HAMM0808 HAMM0909

Metric - Stainless Steel HAMS0304 HAMS0404 HAMS0505 HAMS0606 HAMS0707 HAMS0808 HAMS0909

NPT Thread - Brass HAA0304 HAA0404 HAA0505 HAA0606 HAA0707 HAA0808 HAA0909

NPT Thread - Nickel Plated HAAM0304 HAAM0404 HAAM0505 HAAM0606 HAAM0707 HAAM0808 HAAM0909

NPT Thread - Stainless Steel HAAS0304 HAAS0404 HAAS0505 HAAS0606 HAAS0707 HAAS0808 HAAS0909

See pages 140-143 for suitable conduits

Related Products

Technical Specifi cationsATEX Flameproof Group II Gland

For Accessories see page 166

Thomas & Betts • www.tnb-hazardous.com

General Oil Resistant 140

High Temperature Conduit 142

Low Fire Flexible Conduit 140

Sealing 166Washers

Page 148: Catalog Thomas Betts

• Constructed from either Brass or Stainless Steel with

an epoxy resin barrier

• The Group I Universal Flameproof Gland is a high specification

product, ideal for all hazardous area applications

Approvals / Characteristics Features

Universal Gland & Universal Swivel Gland

Liquid tight hazardous area fl ameproof glands

EC TYPE Examination Certificate:ATEX: Sira 09 ATEX 1231XIECEx: IECEx SIR09.0103XCSA: CSA File No: 2310045GOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0339XEx de I MbEx de IIC GbEx tb IIIC DbClass I DIv 1 BCD (Rigid conduit only)Class I Div 2 ABCDClass II Div 1 ABCDTemperature: -60ºC to +130ºC

Certifi cation & Standards

1DIV

2DIV

I

148

1DIV

Thomas & Betts • www.tnb-hazardous.com

Page 149: Catalog Thomas Betts

149

Liquid Tight Hazardous Areas Flameproof Universal Gland

Metric Thread Size (mm) 20 20 25 32 40 50 63

Type NPT Thread Size (inch) 3/8 1/2 3/4 1 11/4 11/2 2

Metric - Brass HAM0304U/SW HAM0404U/SW HAM0505U/SW HAM0606U/SW HAM0707U/SW HAM0808U/SW HAM0909U/SW

Metric - Nickel Plated HAMM0304U/SW HAMM0404U/SW HAMM0505U/SW HAMM0606U/SW HAMM0707U/SW HAMM0808U/SW HAMM0909U/SW

NPT Thread - Brass HAA0304U/SW HAA0404U/SW HAA0505U/SW HAA0606U/SW HAA0707U/SW HAA0808U/SW HAA0909U/SW

NPT Thread - Nickel Plated HAAM0304U/SW HAAM0404U/SW HAAM0505U/SW HAAM0606U/SW HAAM0707U/SW HAAM0808U/SW HAAM0909U/SW

Metric Thread Size (mm) 20 20 25 32 40 50 63

Type NPT Thread Size (inch) 3/8 1/2 3/4 1 11/4 11/2 2

Metric - Brass HAM0304U HAM0404U HAM0505U HAM0606U HAM0707U HAM0808U HAM0909U

Metric - Nickel Plated HAMM0304U HAMM0404U HAMM0505U HAMM0606U HAMM0707U HAMM0808U HAMM0909U

Metric - Stainless Steel HAMS0304U HAMS0404U HAMS0505U HAMS0606U HAMS0707U HAMS0808U HAMS0909U

NPT Thread - Brass HAA0304U HAA0404U HAA0505U HAA0606U HAA0707U HAA0808U HAA0909U

NPT Thread - Nickel Plated HAAM0304U HAAM0404U HAAM0505U HAAM0606U HAAM0707U HAAM0808U HAAM0909U

NPT Thread - Stainless Steel HAAS0304U HAAS0404U HAAS0505U HAAS0606U HAAS0707U HAAS0808U HAAS0909U

For use with all conduits including Rigid

HAA 03 04 U

Thread B = 1/2” NPTThread A = 3/8” NPT

THREAD B THREAD A THREAD B THREAD A

HAM 03 04 U

Thread A = M16 Thread B = M20

Technical Specifi cationsDimensions

Universal Gland

Universal Swivel Gland

Flameproof GlandConstructed from either brass or stainless steel, with an epoxy resin barrier, the Group I Flameproof Universal Gland is a high quality, high specifi cation product, ideal for Ex I & II 2 GD gas and dust, Exde IIC and Exe II applications, Extb II applications.

Related Products

For Accessories see page 166

Thomas & Betts • www.tnb-hazardous.com

General Oil Resistant 140

High Temperature Conduit 142

Low Fire Flexible Conduit 140

Sealing 166Washers

Page 150: Catalog Thomas Betts

• Solid brass cable gland

• Single compression for non-armoured cable (PA)

• Double compression for armoured cable (PAP)

Approvals / Characteristics Features

PA / PAP NPT Range

Cable glands

150

Thomas & Betts • www.tnb-hazardous.com

Approved to: EN60079-0, 60079-1, 60079-7, EN61241-0, EN61421-1EC TYPE Examination Certificate:INERIS 06 ATEX 0014XEx II 2 GD / I M2Ex d IIC / Ex e II / Ex d I / Ex e IEx tD A21 IP66/68Temperature: -40ºC to +100ºC

Certifi cation & Standards

Page 151: Catalog Thomas Betts

151

PA / PAP NPT Range

Technical Specifi cationsDimensions

GlandMarine grade brassOption: nickel chromed brass and stainless steelIngress rating IP66 (EN 60529), neoprene compression gasket

ThreadsNPT threads, for size see tableOptions: ISO threadsSleeve

Sealing 166Washers

Related Products

For Accessories see page 166

ø Min-Max

External Dimension (mm) Weight

PN Type (mm) D E F L (kg)

PA18L PA1-8 1/2” 5.5-8 41 32 35 18 0.15

PA110L PA1-10 1/2” 8-10.5 41 32 35 18 0.15

PA113L PA1-13 1/2” 10.5-13 41 32 35 18 0.15

PA210L PA2-10 3/4” 8-10.5 41 32 35 18 0.15

PA213L PA2-13 3/4” 10.5-13 41 32 35 18 0.15

PA215L PA2-15 3/4” 13-15.5 41 36 39 18 0.20

PA218L PA2-18 3/4” 15.5-18 41 36 39 18 0.20

PA318L PA3-18 1” 15-18 52 45 49 22 0.38

PA321L PA3-21 1” 18-21 52 45 49 22 0.38

PA324L PA3-24 1” 21-24 52 45 49 22 0.38

PA424L PA4-24 1,1/4” 21-24 53 50 55 22 0.42

PA427L PA4-27 1,1/4” 24-27 53 50 55 22 0.42

PA430L PA4-30 1,1/4” 27-30 53 50 55 22 0.42

PA533L PA5-33 1,1/2” 30-33 53 57 62 22 0.52

PA536L PA5-36 1,1/2” 33-36 53 57 62 22 0.52

PA639L PA6-39 2” 36-39 53 67 73 22 0.75

PA642L PA6-42 2” 39-42 53 67 73 22 0.75

PA645L PA6-45 2” 42-45 53 67 73 22 0.75

PA748L PA7-48 2,1/2” 45-48 53 80 88 27 1.20

PA751L PA7-51 2,1/2” 48-51 53 80 88 27 1.20

ø Min-Max

Internal External Dimension (mm) Weight

PN Type (mm) (mm) D E F L (kg)

PAP18L PAP1-8 1/2” 5,5-8 10-15 65 32 35 18 0,22

PAP110L PAP1-10 1/2” 8-10.5 10-15 65 32 35 18 0.22

PAP113L PAP1-13 1/2” 10.5-13 14-19 65 32 35 18 0.22

PAP210L PAP2-10 3/4” 8-10.5 10-15 65 32 35 18 0.22

PAP213L PAP2-13 3/4” 10.5-13 15-20 65 32 35 18 0.22

PAP215L PAP2-15 3/4” 13-15.5 15-20 65 36 39 18 0.29

PAP218L PAP2-18 3/4” 15.5-18 19-24 65 36 39 18 0.29

PAP318L PAP3-18 1” 15-18 20-26 82 45 49 22 0.50

PAP321L PAP3-21 1” 18-21 20-26 82 45 49 22 0.50

PAP324L PAP3-24 1” 21-24 25-31 82 45 49 22 0.50

PAP424L PAP4-24 1,1/4” 21-24 26-32 83 50 55 22 0.55

PAP427L PAP4-27 1,1/4” 24-27 26-32 83 50 55 22 0.55

PAP430L PAP4-30 1,1/4” 27-30 31-37 83 50 55 22 0.55

PAP533L PAP5-33 1,1/2” 30-33 36-43 83 57 62 22 0.70

PAP536L PAP5-36 1,1/2” 33-36 36-43 83 57 62 22 0.70

PAP639L PAP6-39 2” 36-39 42-48 83 67 73 22 0.85

PAP642L PAP6-42 2” 39-42 42-48 83 67 73 22 0.85

PAP645L PAP6-45 2” 42-45 47-53 83 67 73 22 0.85

PAP748L PAP7-48 2,1/2” 45-48 52-58 83 80 88 27 1.45

PAP751L PAP7-51 2,1/2” 48-51 52-58 83 80 88 27 1.45

XB-A Range 118 GUV Range 124Locknuts 166

Thomas & Betts • www.tnb-hazardous.com

Page 152: Catalog Thomas Betts

• Nickel chromed brass cable gland

• Single compression for non-armoured cable (PE)

• Double compression for armoured cable (PEP)

Approvals / Characteristics Features

PE / PEP ISO Range

Cable glands

152

Thomas & Betts • www.tnb-hazardous.com

Approved to: EN60079-0, 60079-1, 60079-7, EN61241-0, EN61421-1EC TYPE Examination Certificate:LCIE 97 ATEX 6008X / IECEx LCI 05.0004XEx II 2 GDEx d IIC / Ex e II / Ex tDEx tD A21 IP66/68Temperature: -60ºC to +80ºC or -40ºC to 100ºC

Certifi cation & Standards

Page 153: Catalog Thomas Betts

153

PE / PEP ISO Range

Technical Specifi cationsDimensions

GlandNickel chrome brassOption: stainless steelIngress rating IP68 10 bar (EN 60529), neoprene compression gasket

ThreadsNPT threads, for size see tableOptions: Clamping moduleLead sheaf earthing washerShroud

Related Products

For Accessories see page 166

ø Min-Max

External Dimension (mm)

Type (mm) E F D L Weight (kg)

PEM20T4 4-8.5 15 24 20 15 0.056

PEM20T5 6-12 19 24 22 15 0.038

PEM20T6 8.5-15 24 24 25 15 0.045

PEM25T6 8.5-16 24 30 25 15 0.055

PEM25T7 12-20.5 30 30 27 15 0.070

PEM32T7 12-21 30 36 27 15 0.100

PEM32T8 16-27.5 41 41 34 15 0.150

PEM40T9 21-33 48 48 36 15 0.210

PEM50T10 27-41 55 55 39 16 0.285

PEM63T11 33-48 64 67 41 17 0.400

PEM75T12 40-56 72 80 43 18 0.570

ø Min-Max

Internal External Dimension (mm)

Type (mm) (mm) E F D L Weight (kg)

PEPM20T5 4-8.5 6-12 19 24 36 15 0.080

PEPM20T6 6-12 8.5-16 24 24 42 15 0.090

PEPM20T7 8.5-15.5 12-21 30 30 46 15 0.123

PEPM25T7 8.5-16 12-21 30 30 46 15 0.170

PEPM25T8 12-21 16-27.5 41 41 56 15 0.270

PEPM32T8 12-21 16-27.5 41 41 56 15 0.310

PEPM32T9 16-27.5 21-33 48 48 63 15 0.400

PEPM40T10 21-33 27-41 55 55 68 15 0.540

PEPM50T11 27-41 33-48 64 64 74 16 0.735

PEPM63T12 33-48 40-56 72 72 77 17 0.996

PEPM75T13 40-55 47-65 85 85 85 18 1.590

Sealing 166Washers

XB-A Range 118 GUV Range 124Locknuts 166

Thomas & Betts • www.tnb-hazardous.com

Page 154: Catalog Thomas Betts

• Solid Brass Nickel cable gland

• Single compression for non-armoured cable (PA-B)

• Double compression for armoured cable (PAP-B)

• Accessories included - compound kit and different

rings to cover multi-cable sizes

Approvals / Characteristics Features

PA-B / PAP-B NPT & ISO Range

Barrier compound cable glands

154

Thomas & Betts • www.tnb-hazardous.com

Approved to: EN60079-0, 60079-1, 60079-7, EN61241-0, EN61421-1EC TYPE Examination Certificate:INERIS 06 ATEX 0014XEx II 2 GD / I M2Ex d IIC / Ex e II / Ex d I / Exe IEx tD A21 IP66/68Temperature: -40ºC to 100ºC

Certifi cation & Standards

Page 155: Catalog Thomas Betts

PA-B / PAP-B NPT & ISO Range

155

ø Min-Max

External Dimension (mm)

Type (mm) D E F L Weight (kg)

PA1B-1/2NPT 5,5-8 40 32 35 18 0,156

8-10.5 40 32 35 18 0.156

10.5-13 40 32 35 18 0.156

PA2B-3/4NPT 8-10.5 40 36 39 18 0.20

10.5-13 40 36 39 18 0.20

13-15.5 40 36 39 18 0.20

15.5-18 40 36 39 18 0.20

PA3B-1NPT 15-18 52 45 49 22 0.38

18-21 52 45 49 22 0.38

21-24 52 45 49 22 0.38

PA4B-1,1/4NPT 21-24 52 50 55 22 0.421

24-27 52 50 55 22 0.421

27-30 52 50 55 22 0.421

PA5B-1,1/2NPT 30-33 52 57 62 22 0.537

33-36 52 57 62 22 0.537

PA6B-2NPT 36-39 52 67 72 22 0.75

39-42 52 67 72 22 0.75

42-45 52 67 72 22 0.75

PA7B-2,1/2NPT 45-48 52 80 88 27 1.20

48-51 52 80 88 27 1.20

51-54 52 80 88 27 1.20

ø Min-Max

Internal External Dimension (mm)

Type (mm) (mm) D E F L Weight (kg)

PAP1B-1/2NPT 5,5-8 10-15 64 32 35 18 0,228

8-10.5 10-15 64 32 35 18 0.228

10.5-13 14-19 64 32 35 18 0.228

PAP2B-3/4NPT 8-10.5 10-15 65 32 35 18 0.22

10.5-13 15-20 65 32 35 18 0.22

13-15.5 15-20 64 36 39 18 0.29

15.5-18 19-24 64 36 39 18 0.29

PAP3B-1NPT 15-18 20-26 83 45 49 22 0.50

18-21 20-26 83 45 49 22 0.50

21-24 25-31 83 45 49 22 0.50

PAP4B-1,1/4NPT 21-24 26-32 83 50 55 22 0.576

24-27 26-32 83 50 55 22 0.576

27-30 31-37 83 50 55 22 0.576

PAP5B-1,1/2NPT 30-33 36-43 83 57 62 22 0.730

33-36 36-43 83 57 62 22 0.730

PAP6B-2NPT 36-39 42-48 83 67 73 22 0.961

39-42 42-48 83 67 73 22 0.961

42-45 47-53 83 67 73 22 0.961

PAP7B-2,1/2NPT 45-48 52-58 83 80 88 27 1.45

48-51 52-58 83 80 88 27 1.45

51-54 52-58 83 80 88 27 1.45

Technical Specifi cationsDimensions

ø Min-Max

External Dimension (mm)

Type (mm) D E F L Weight (kg)

PA1B-M20 5,5-8 40 32 35 18 0,156

8-10.5 40 32 35 18 0.156

10.5-13 40 32 35 18 0.156

PA2B-M25 8-10.5 40 36 39 18 0.20

10.5-13 40 36 39 18 0.20

13-15.5 40 36 39 18 0.20

15.5-18 40 36 39 18 0.20

PA3B-M32 15-18 52 45 49 22 0.38

18-21 52 45 49 22 0.38

21-24 52 45 49 22 0.38

PA4B-M40 21-24 52 50 55 22 0.421

24-27 52 50 55 22 0.421

27-30 52 50 55 22 0.421

PA5B-M50 30-33 52 57 62 22 0.537

33-36 52 57 62 22 0.537

PA6B-M63 36-39 52 67 72 22 0.75

39-42 52 67 72 22 0.75

42-45 52 67 72 22 0.75

PA7B-M75 45-48 52 80 88 27 1.20

48-51 52 80 88 27 1.20

51-54 52 80 88 27 1.20

ø Min-Max

Internal External Dimension (mm)

Type (mm) (mm) D E F L Weight (kg)

PAP1B-M20 5,5-8 10-15 64 32 35 18 0,228

8-10.5 10-15 64 32 35 18 0.228

10.5-13 14-19 64 32 35 18 0.228

PAP2B-M25 8-10.5 10-15 65 32 35 18 0.22

10.5-13 15-20 65 32 35 18 0.22

13-15.5 15-20 64 36 39 18 0.29

15.5-18 19-24 64 36 39 18 0.29

PAP3B-M32 15-18 20-26 83 45 49 22 0.50

18-21 20-26 83 45 49 22 0.50

21-24 25-31 83 45 49 22 0.50

PAP4B-M40 21-24 26-32 83 50 55 22 0.576

24-27 26-32 83 50 55 22 0.576

27-30 31-37 83 50 55 22 0.576

PAP5B-M50 30-33 36-43 83 57 62 22 0.730

33-36 36-43 83 57 62 22 0.730

PAP6B-M63 36-39 42-48 83 67 73 22 0.961

39-42 42-48 83 67 73 22 0.961

42-45 47-53 83 67 73 22 0.961

PAP7B-M75 45-48 52-58 83 80 88 27 1.45

48-51 52-58 83 80 88 27 1.45

51-54 52-58 83 80 88 27 1.45

Thomas & Betts • www.tnb-hazardous.com

Page 156: Catalog Thomas Betts

• UL Listed for use in hazardous and wet locations

• Corrosion-resistant - ideal for washdown areas

• Flexible bronze construction with arc-resistant inner

sleeve and brass fittings

• Terminated with two threaded female end fittings

and male close nipples

• No bonding jumper required

156

1DIV

2DIV

I

1DIV

Approvals / Characteristics Features

XP Flex™ RangeExplosion-proof fl exible couplings

UL Listed and CSA Certified for Hazardous Locations:0.5” and 0.75” Hub Sizes: Class I Div 1 & 2 ABCD; Class II Div 1 EFG, Class III1” Hub Size: Class I Div 1 & 2 CD; Class II Div 1 EFG, Class IIIUL Listed 886

Certifi cation & Standards

Thomas & Betts • www.tnb-hazardous.com

Page 157: Catalog Thomas Betts

Explosion-Proof Flexible Couplings - XP Flex™ Range

Dimensions (mm)

Reference Thread Type (inch) Flexible Length (mm) A B

XPLFL16 1/2” NPT 150 39.1 36.6

XPLFL18 1/2” NPT 200 39.1 36.6

XPLFL110 1/2” NPT 250 39.1 36.6

XPLFL112 1/2” NPT 300 39.1 36.6

XPLFL115 1/2” NPT 380 39.1 36.6

XPLFL118 1/2” NPT 460 39.1 36.6

XPLFL124 1/2” NPT 610 39.1 36.6

XPLFL212 3/4” NPT 300 40.6 47.5

XPLFL215 3/4” NPT 380 40.6 47.5

XPLFL218 3/4” NPT 460 40.6 47.5

XPLFL224 3/4” NPT 610 40.6 47.5

XPLFL236 3/4” NPT 915 40.6 47.5

XPLFL318 1” NPT 460 50.08 58.7

157

Explosion-Proof and Dust- Ignition-Proof for Use in Hazardous LocationsWith their fl exible design, T&B® XP FlexTM Couplings make it easy to achieve tight bends in conduit systems in confi ned spaces - or to connect stationary equipment to equipment that moves or vibrates. Their explosion-proof and corrosion-resistant construction mean you can use them with confi dence in hazardous and wet locations.

Technical Specifi cationsDimensions

FlexibleLength

AB

NPTThreads

Enlargers, Reducers & Thread Convertors 160

Sealing 166Washers

Related Products

Locknuts 166

Thomas & Betts • www.tnb-hazardous.com

Page 158: Catalog Thomas Betts

• Adaptors and Reducers provide a method of

matching threadforms on hazardous approved

equipment whilst ensuring the integrity and approval

of the installation is maintained

Approvals / Characteristics Features

Thread ConvertorsEnlargers, reducers & convertors

Certification Standard: ATEX: Baseefa07 ATEX 0247X, IECEx: IECEx BAS07.0090XGOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0339XClass I Div1 ABCD, Class II Div1 EFG (does not include M16 & 3/8”NPT or unplated brass products)Approved to UL 1203Approved to CSA C22.2 No.60079-04Approved to C22.2 No.60079-1

Certifi cation & Standards

158

1DIV

I 1DIV

Thomas & Betts • www.tnb-hazardous.com

Page 159: Catalog Thomas Betts

Male

External Metric Female Internal Thread

Thread M16 M20 M25 M32 M40 M50 M63 M75

M16 EX/M16-M20/E EX/M16-M25/E

M20 EX/M20-M16/R EX/M20-M25/E EX/M20-M32/E

M25 EX/M25-M16/R EX/M25-M20/R EX/M25-M32/E EX/M25-M40/E

M32 EX/M32-M16/R EX/M32-M20/R EX/M32-M25/R EX/M32-M40/E EX/M32-M50/E

M40 EX/M40-M16/R EX/M40-M20/R EX/M40-M25/R EX/M40-M32/R EX/M40-M50/E EX/M40-M63/E

M50 EX/M50-M16/R EX/M50-M20/R EX/M50-M25/R EX/M50-M32/R EX/M50-M40/R EX/M50-M63/E EX/M50-M75/E

M63 EX/M63-M16/R EX/M63-M20/R EX/M63-M25/R EX/M63-M32/R EX/M63-M40/R EX/M63-M50/R EX/M63-M75/E

M75 EX/M75-M16/R EX/M75-M20/R EX/M75-M25/R EX/M75-M32/R EX/M75-M40/R EX/M75-M50/R EX/M75-M63/R

PG9 EX/PG9-M16/TC EX/PG9-M20/TC

PG11 EX/PG11-M16/TC EX/PG11-M20/TC

PG13 EX/PG13-M16/TC EX/PG13-M20/TC

PG16 EX/PG16-M16/TC EX/PG16-M20/TC EX/PG16-M25/TC

PG21 EX/PG21-M16/TC EX/PG21-M20/TC EX/PG21-M25/TC EX/PG21-M32/TC

PG29 EX/PG29-M16/TC EX/PG29-M20/TC EX/PG29-M25/TC EX/PG29-M32/TC EX/PG29-M40/TC

PG36 EX/PG36-M16/TC EX/PG36-M20/TC EX/PG36-M25/TC EX/PG36-M32/TC EX/PG36-M40/TC EX/PG36-M50/TC

PG42 EX/PG42-M16/TC EX/PG42-M20/TC EX/PG42-M25/TC EX/PG42-M32/TC EX/PG42-M40/TC EX/PG42-M50/TC EX/PG42-M63/TC

PG48 EX/PG48-M16/TC EX/PG48-M20/TC EX/PG48-M25/TC EX/PG48-M32/TC EX/PG48-M40/TC EX/PG48-M50/TC EX/PG48-M63/TC

NPT 3/8 EX/038-M16/TC

NPT 1/2 EX/050-M16/TC EX/050-M20/TC EX/050-M25/TC

NPT 3/4 EX/075-M16/TC EX/075-M20/TC EX/075-M25/TC EX/075-M32/TC

NPT 1 EX/100-M16/TC EX/100-M20/TC EX/100-M25/TC EX/100-M32/TC EX/100-M40/TC

NPT 1 1/4 EX/125-M16/TC EX/125-M20/TC EX/125-M25/TC EX/125-M32/TC EX/125-M40/TC EX/125-M50/TC

NPT 1 1/2 EX/150-M16/TC EX/150-M20/TC EX/150-M25/TC EX/150-M32/TC EX/150-M40/TC EX/150-M50/TC EX/150-M63/TC

NPT 2 EX/200-M16/TC EX/200-M20/TC EX/200-M25/TC EX/200-M32/TC EX/200-M40/TC EX/200-M50/TC EX/200-M63/TC

NPT 2 1/2 EX/250-M16/TC EX/250-M20/TC EX/250-M25/TC EX/250-M32/TC EX/250-M40/TC EX/250-M50/TC

NPT 3 EX/300-M16/TC EX/300-M20/TC EX/300-M25/TC EX/300-M32/TC EX/300-M40/TC EX/300-M50/TC EX/300-M75/TC

*For Nickel Plated Brass version, add N to the reference, e.g. EXN/M20-M16/R**For Stainless Steel 316 version, add S to the reference, e.g. EXS/M20-M16/R

Enlargers, Reducers & Thread Convertors

159

Metric - Technical Specifi cation

Connector Description:EX - BrassEXN - Nickel Plated BrassEXS - Stainless Steel 316

Enlargers (/E) are used where the thread size of the Female side of the device is larger than the male side.Reducers (/R) are used where the thread size of the female side of device is smaller than the male side.Thread Converters (/TC) are used where a conversion is required between thread types, e.g. Metric to PG.

Our comprehensive range of Adaptors and Reducers provide a method of matching threadforms on hazardous area approved equipment whilst ensuring the integrity and approval of the installation is maintained.

Manufactured in the UK, this new range of converters meets the latest ATEX / IECEx & CSA / UL standards. This means that all the standards are marked on the product around the main body. This allows for them to be seen easily once installed, a key component of the new standard.

Kopex’s Enlargers, Reducers and thread converters are designed for hazardous area applications and are certifi ed to protection concepts Exd “Flameproof” and Exe “Increased Safety” for use in Zone 1, 2, 2.1, 2.2 applications. Under NEC Class I Div1 ABCD Class II Div1 EFG.

EFDC Range 126 XB100 Range 108

Related Products

GUV Range 124 PA Gland 152

Thomas & Betts • www.tnb-hazardous.com

Page 160: Catalog Thomas Betts

160

Male

External NPT Female Internal Thread

Thread NPT 1/2 NPT 3/4 NPT 1 NPT 1 1/4 NPT 1 1/2 NPT 2 NPT 2 1/2 NPT 3

M16 EX/M16-050/TC

M20 EX/M20-050/TC EX/M20-075/TC

M25 EX/M25-050/TC EX/M25-075/TC EX/M25-100/TC

M32 EX/M32-050/TC EX/M32-075/TC EX/M32-100/TC EX/M32-125/TC

M40 EX/M40-050/TC EX/M40-075/TC EX/M40-100/TC EX/M40-125/TC EX/M40-150/TC

M50 EX/M50-050/TC EX/M50-075/TC EX/M50-100/TC EX/M50-125/TC EX/M50-150/TC EX/M50-200/TC

M63 EX/M63-050/TC EX/M63-075/TC EX/M63-100/TC EX/M63-125/TC EX/M63-150/TC EX/M63-200/TC

M75 EX/M75-050/TC EX/M75-075/TC EX/M75-100/TC EX/M75-125/TC EX/M75-150/TC EX/M75-200/TC

PG9 EX/PG9-050/TC

PG11 EX/PG11-050/TC

PG13 EX/PG13-050/TC

PG16 EX/PG16-050/TC EX/PG16-075/TC

PG21 EX/PG21-050/TC EX/PG21-075/TC EX/PG21-100/TC

PG29 EX/PG29-050/TC EX/PG29-075/TC EX/PG29-100/TC EX/PG29-125/TC EX/PG29-150/TC

PG36 EX/PG36-050/TC EX/PG36-075/TC EX/PG36-100/TC EX/PG36-125/TC EX/PG36-150/TC

PG42 EX/PG42-050/TC EX/PG42-075/TC EX/PG42-100/TC EX/PG42-125/TC EX/PG42-150/TC EX/PG42-200/TC

PG48 EX/PG48-050/TC EX/PG48-075/TC EX/PG48-100/TC EX/PG48-125/TC EX/PG48-150/TC EX/PG48-200/TC

NPT 1/2 EX/050-075/E

NPT 3/4 EX/075-050/R EX/075-100/E

NPT 1 EX/100-050/R EX/100-075/R EX/100-125/E

NPT 1 1/4 EX/125-050/R EX/125-075/R EX/125-100/R EX/125-150/E

NPT 1 1/2 EX/150-050/R EX/150-075/R EX/150-100/R EX/150-125/R EX/150-200/E

NPT 2 EX/200-050/R EX/200-075/R EX/200-100/R EX/200-125/R X/200-150/R

NPT 2 1/2 EX/250-050/R EX/250-075/R EX/250-100/R EX/250-125/R EX/250-150/R EX/250-200/R EX/250-300/E

NPT 3 EX/300-050/R EX/300-075/R EX/300-100/R EX/300-125/R EX/300-150/R EX/300-200/R EX/300-250/R

*For Nickel Plated Brass version, add N to the reference, e.g. EXN/M20-M16/R**For Stainless Steel 316 version, add S to the reference, e.g. EXS/M20-M16/R

NPT - Technical Specifi cation

Thomas & Betts • www.tnb-hazardous.com

Page 161: Catalog Thomas Betts

Male

External PG Female Internal Thread

Thread PG9 PG11 PG13 PG16 PG21 PG29 PG36 PG42 PG48

M16 EX/M16-PG9/TC EX/M16-PG11/TC EX/M16-PG13/TC

M20 EX/M20-PG9/TC EX/M20-PG11/TC EX/M20-PG13/TC EX/M20-PG16/TC

M25 EX/M25-PG9/TC EX/M25-PG11/TC EX/M25-PG13/TC EX/M25-PG16/TC EX/M25-PG21/TC

M32 EX/M32-PG9/TC EX/M32-PG11/TC EX/M32-PG13/TC EX/M32-PG16/TC EX/M32-PG21/TC EX/M32-PG29/TC

M40 EX/M40-PG9/TC EX/M40-PG11/TC EX/M40-PG13/TC EX/M40-PG16/TC EX/M40-PG21/TC EX/M40-PG29/TC EX/M40-PG36/TC

M50 EX/M50-PG9/TC EX/M50-PG11/TC EX/M50-PG13/TC EX/M50-PG16/TC EX/M50-PG21/TC EX/M50-PG29/TC EX/M50-PG36/TC EX/M50-PG42/TC

M63 EX/M63-PG9/TC EX/M63-PG11/TC EX/M63-PG13/TC EX/M63-PG16/TC EX/M63-PG21/TC EX/M63-PG29/TC EX/M63-PG36/TC EX/M63-PG42/TC EX/M63-PG48/TC

M75 EX/M75-PG9/TC EX/M75-PG11/TC EX/M75-PG13/TC EX/M75-PG16/TC EX/M75-PG21/TC EX/M75-PG29/TC EX/M75-PG36/TC EX/M75-PG42/TC EX/M75-PG48/TC

PG11 EX/PG11-PG9/R

PG13 EX/PG13-PG9/R EX/PG13-PG11/R

PG16 EX/PG16-PG9/R EX/PG16-PG11/R EX/PG16-PG13/R EX/P16-PG21/E

PG21 EX/PG21-PG9/R EX/PG21-PG11/R EX/PG21-PG13/R EX/PG21-PG16/R EX/PG21-PG29/E

PG29 EX/PG29-PG9/R EX/PG29-PG11/R EX/PG29-PG13/R EX/PG29-PG16/R EX/PG29-PG21/R EX/PG29-PG36/E

PG36 EX/PG36-PG9/R EX/PG36-PG11/R EX/PG36-PG13/R EX/PG36-PG16/R EX/PG36-PG21/R EX/PG36-PG29/R EX/PG36-PG48/E

PG42 EX/PG42-PG9/R EX/PG42-PG11/R EX/PG42-PG13/R EX/PG42-PG16/R EX/PG42-PG21/R EX/PG42-PG29/R EX/PG42-PG36/R EX/PG42-PG48/E

PG48 EX/PG48-PG9/R EX/PG48-PG11/R EX/PG48-PG13/R EX/PG48-PG16/R EX/PG48-PG21/R EX/PG48-PG29/R EX/PG48-PG36/R EX/PG48-PG42/R

NPT 1/2 EX/050-PG9/TC EX/050-PG11/TC EX/050-PG13/TC EX/050-PG16/TC

NPT 3/4 EX/075-PG9/TC EX/075-PG11/TC EX/075-PG13/TC EX/075-PG16/TC EX/075-PG21/TC

NPT 1 EX/100-PG9/TC EX/100-PG11/TC EX/100-PG13/TC EX/100-PG16/TC EX/100-PG21/TC EX/100-PG29/TC

NPT 1 1/4 EX/125-PG9/TC EX/125-PG11/TC EX/125-PG13/TC EX/125-PG16/TC EX/125-PG21/TC EX/125-PG29/TC EX/125-PG36/TC

NPT 1 1/2 EX/150-PG9/TC EX/150-PG11/TC EX/150-PG13/TC EX/150-PG16/TC EX/150-PG21/TC EX/150-PG29/TC EX/150-PG36/TC EX/150-PG42/TC

NPT 2 EX/200-PG9/TC EX/200-PG11/TC EX/200-PG13/TC EX/200-PG16/TC EX/200-PG21/TC EX/200-PG29/TC EX/200-PG36/TC EX/200-PG42/TC EX/200-PG48/TC

*For Nickel Plated Brass version, add N to the reference, e.g. EXN/M20-M16/R**For Stainless Steel 316 version, add S to the reference, e.g. EXS/M20-M16/R

Enlargers, Reducers & Thread Convertors

161

PG - Technical Specifi cation

Connector Description:EX - BrassEXN - Nickel Plated BrassEXS - Stainless Steel 316

Enlargers (/E) are used where the thread size of the Female side of the device is larger than the male side.Reducers (/R) are used where the thread size of the female side of device is smaller than the male side.Thread Converters (/TC) are used where a conversion is required between thread types, e.g. Metric to PG.

Our comprehensive range of Adaptors and Reducers provide a method of matching threadforms on hazardous area approved equipment whilst ensuring the integrity and approval of the installation is maintained.

Manufactured in the UK, this new range of converters meets the latest ATEX / IECEx & CSA / UL standards. This means that all the standards are marked on the product around the main body. This allows for them to be seen easily once installed, a key component of the new standard.

Kopex’s Enlargers, Reducers and thread converters are designed for hazardous area applications and are certifi ed to protection concepts Exd “Flameproof” and Exe “Increased Safety” for use in Zone 1, 2, 2.1, 2.2 applications. Under NEC Class I Div1 ABCD Class II Div1 EFG.

Related Products

Thomas & Betts • www.tnb-hazardous.com

EFDC Range 126 XB100 Range 108GUV Range 124 PA Gland 152

Page 162: Catalog Thomas Betts

• For use in potentially explosive atmospheres

• Manufactured from either Brass, Nickel Plated Brass

or Stainless Steel

Approvals / Characteristics Features

Standard Ex d Stopping Plug & Tamperproof Ex d Stopping Plug

Exd stopping plugs

EC TYPE Examination Certificate:ATEX: Baseefa 08 ATEX 6324IECEx: IECEx BAS08.0109XGOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0093UL 1203 (Nickel Plated Brass and Stainless Steel only)Ex d IEx d IICClass I Div 1 ABCDClass II Div 1 EFGTemperature: -60ºC to +130ºC

Certifi cation & Standards

1DIV

I 1DIV

162

Thomas & Betts • www.tnb-hazardous.com

Page 163: Catalog Thomas Betts

163

Ex d Stopping Plugs

NPT Thread Size (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Type Metric Thread Size (mm) 16 20 25 32 40 50 63

NPT Thread - Brass EX/038/SP EX/050/SP EX/075/SP EX/100/SP EX/125/SP EX/150/SP EX/200/SP

Metric - Brass EX/M16/SP EX/M20/SP EX/M25/SP EX/M32/SP EX/M40/SP EX/M50/SP EX/M63/SP

NPT Thread - Nickel Plated Brass EXN/038/SP EXN/050/SP EXN/075/SP EXN/100/SP EXN/125/SP EXN/150/SP EXN/200/SP

Metric - Nickel Plated Brass EXN/M16/SP EXN/M20/SP EXN/M25/SP EXN/M32/SP EXN/M40/SP EXN/M50/SP EXN/M63/SP

NPT Thread - Stainless Steel EXS/038/SP EXS/050/SP EXS/075/SP EXS/100/SP EXS/125/SP EXS/150/SP EXS/200/SP

Metric - Stainless Steel EXS/M16/SP EXS/M20/SP EXS/M25/SP EXS/M32/SP EXS/M40/SP EXS/M50/SP EXS/M63/SP

*Does not include M16 & 3/8 NPT or Unplated Brass products

NPT Thread Size (inch) 3/8 1/2 3/4 1 1 1/4 1 1/2 2

Type Metric Thread Size (mm) 16 20 25 32 40 50 63

NPT Thread - Brass EX/038/TSP EX/050/TSP EX/075/TSP EX/100/TSP EX/125/TSP EX/150/TSP EX/200/TSP

Metric - Brass EX/M16/TSP EX/M20/TSP EX/M25/TSP EX/M32/TSP EX/M40/TSP EX/M50/TSP EX/M63/TSP

NPT Thread - Nickel Plated Brass EXN/038/TSP EXN/050/TSP EXN/075/TSP EXN/100/TSP EXN/125/TSP EXN/150/TSP EXN/200/TSP

Metric - Nickel Plated Brass EXN/M16/TSP EXN/M20/TSP EXN/M25/TSP EXN/M32/TSP EXN/M40/TSP EXN/M50/TSP EXN/M63/TSP

NPT Thread - Stainless Steel EXS/038/TSP EXS/050/TSP EXS/075/TSP EXS/100/TSP EXS/125/TSP EXS/150/TSP EXS/200/TSP

Metric - Stainless Steel EXS/M16/TSP EXS/M20/TSP EXS/M25/TSP EXS/M32/TSP EXS/M40/TSP EXS/M50/TSP EXS/M63/TSP

*Does not include M16 & 3/8 NPT or Unplated Brass products

Related Products

Technical Specifi cationsStandard Exd Stopping Plug

Tamperproof Exd Stopping Plug

XFF Range 28 GUV Range 124EJB Range 128 XEL Range 32

Thomas & Betts • www.tnb-hazardous.com

Page 164: Catalog Thomas Betts

• For use in potentially explosive atmospheres

• Hex Head and Dome Head stopping plugs manufactured

from either Brass, Nickel Plated Brass or Stainless Steel

• Nylon Stopping Plug manufactured in Nylon only

Approvals / Characteristics Features

Hex Head Ex e Stopping Plug / Dome Head Ex e & Nylon Stopping Plug

Ex e & nylon stopping plugs

Hex Head Exe Stopping Plug & Dome Head Stopping PlugEC TYPE Examination Certificate:ATEX: Baseefa 08 ATEX 0325XIECEx: IECEx BAS08.0108XGOST R: POCC GB.ГБ05.B03850INMETRO: TÜV 11.0090UL 1203 (Nickel Plated Brass and Stainless Steel only)Ex d IEx e II Ex tDTemperature: -60ºC to +80ºC

Certifi cation & Standards

164

Nylon Stopping PlugEC TYPE Examination Certificate:Sira 00 ATEX 1074XLCIE 98 ATEX 0001U

Thomas & Betts • www.tnb-hazardous.com

Page 165: Catalog Thomas Betts

165

Ex e & Nylon Stopping Plugs

Type Metric Thread Size (mm) 16 20 25 32 40 50 63

Metric - Brass EX/M16/HSP EX/M20/HSP EX/M25/HSP EX/M32/HSP EX/M40/HSP EX/M50/HSP EX/M63/HSP

Metric - Nickel Plated Brass EXN/M16/HSP EXN/M20/HSP EXN/M25/HSP EXN/M32/HSP EXN/M40/HSP EXN/M50/HSP EXN/M63/HSP

Metric - Stainless Steel EXS/M16/HSP EXS/M20/HSP EXS/M25/HSP EXS/M32/HSP EXS/M40/HSP EXS/M50/HSP EXS/M63/HSP

*Does not include M16 & 3/8 NPT or Unplated Brass products

Related Products

Technical Specifi cationsHex Head Exe Stopping Plug

Type Metric Thread Size (mm) 16 20 25 32 40 50 63

Metric - Brass EX/M16/DSP EX/M20/DSP EX/M25/DSP EX/M32/DSP EX/M40/DSP EX/M50/DSP EX/M63/DSP

Metric - Nickel Plated Brass EXN/M16/DSP EXN/M20/DSP EXN/M25/DSP EXN/M32/DSP EXN/M40/DSP EXN/M50/DSP EXN/M63/DSP

Metric - Stainless Steel EXS/M16/DSP EXS/M20/DSP EXS/M25/DSP EXS/M32/DSP EXS/M40/DSP EXS/M50/DSP EXS/M63/DSP

*Products supplied with sealing washers and ‘O’ rings **Does not include M16 & 3/8 NPT or Unplated Brass products

Dome Head Exe Stopping Plug

XFF Range 28 GUV Range 124XB Range 116 EVS Range 42

Type Metric Thread Size (mm) 16 20 25 32 40 50 63

Metric - Nylon (supplied without locknut) BEM16POLY BEM20POLY BEM25POLY BEM32POLY BEM40POLY BEM50POLY BEM63POLY

Nylon Stopping Plug ( only)

Thomas & Betts • www.tnb-hazardous.com

Page 166: Catalog Thomas Betts

166

Ex e Nylon Gland - Group II, Zones 1, 2, 21 and 22

Coupler - Female to Female thread couplers for use in both Exd and Exe applications

Certification Standard: LCIE 97 ATEX 6007X

Certifi cation & Standards

Certification Standard: Baseefa 08 ATEX 0359U

IECEx BAS08.0121U

TÜV11.0158U

Temperature: -60°C to +200°C

Certifi cation & Standards

Hex Locknut - for Metric Threads and NPT Threads (Nickel Plated Brass only)

Sealing Joint Washer - for use with all ATEX and IECEx approved products (Nylon only)

Certification Standard: Nylon Metric approved for use

with all ATEX / IECEx products

Certifi cation & Standards

Earth Tag - to be used to create an earthing bond on an enclosure, when a cable gland is used

Accessories

Thomas & Betts • www.tnb-hazardous.com

Page 167: Catalog Thomas Betts

Cable Glands, Sealing Washers & Locknuts - Accessories

167

Metric Thread Size (mm) 12 16a 16b 20a 20b 25 32 40 50 63

Type Cable Diameter (mm) 3,5-6 5-8 6-10 8-13 10-15 13-19 17-25 23-32 25-38 34-40

Ex e Nylon Gland PCM12 PCM16A PCM16B PCM20A PCM20B PCM25 PCM32 PCM40 PCM50 PCM63

Ex i Nylon Gland (Blue) PCM12i PCM16iA PCM16iB PCM20iA PCM20iB PCM25i PCM32i PCM40i PCM50i PCM63i

Technical Specifi cations

Metric Thread Size (mm) 16 20 25 32 40 50 63 75

Type PG Thread Size 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2

Metric - Brass EX/M16/C EX/M20/C EX/M25/C EX/M32/C EX/M40/C EX/M50/C EX/M63/C EX/M75/C

NPT Thread - Brass EX/038/C EX/050/C EX/075/C EX/100/C EX/125/C EX/150/C EX/200/C EX/250/P

Metric - Nickel Plated Brass EXN/M16/C EXN/M20/C EXN/M25/C EXN/M32/C EXN/M40/C EXN/M50/C EXN/M63/C EXN/M75/C

NPT Thread - Nickel Plated Brass EXN/038/C EXN/050/C EXN/075/C EXN/100/C EXN/125/C EXN/150/C EXN/200/C EXN/250/P

Metric - Stainless Steel EXS/M16/C EXS/M20/C EXS/M25/C EXS/M32/C EXS/M40/C EXS/M50/C EXS/M63/C EXS/M75/C

NPT Thread - Stainless Steel EXS/038/C EXS/050/C EXS/075/C EXS/100/C EXS/125/C EXS/150/C EXS/200/C EXS/250/P

Metric Thread Size (mm) 16 20 25 32 40 50 63 75

Type PG Thread Size 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2

Metric - Stainless Steel - MXWH04 MXWH05 MXWH06 MXWH07 MXWH08 - -

Metric - Brass WHMB03 WHMB04 WHMB05 WHMB06 WHMB07 WHMB08 - -

Metric - Nickel Plated Brass WHMM03 WHMM04 WHMM05 WHMM06 WHMM07 WHMM08 WHMM09 -

NPT Thread - Nickel Plated Brass - WHAM04 WHAM05 WHAM06 WHAM07 WHAM08 WHAM09 -

Metric Thread Size (mm) 16 20 25 32 40 50 63 75

PG Thread Size 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2

Outside Diameter (mm) 22 26 34.3 41.5 52 66.5 84.5 -

Type Thickness (mm) 1.6 1.6 1.7 1.7 2 2 2 -

Metric - Nylon (ATEX / IECEx approved) EXFM03 EXFM04 EXFM05 EXFM06 EXFM07 EXFM08 EXFM09 -

Metric - Fibre EXFM03F EXFM04F EXFM05F EXFM06F EXFM07F EXFM08F - -

Metric Thread Size (mm) 16 20 25 32 40 50 63 75

Type PG Thread Size 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2

Earth Tag - Brass EX/M16/TAG EX/M20/TAG EX/M25/TAG EX/M32/TAG EX/M40/TAG EX/M53/TAG EX/M63/TAG EX/M75/TAG

EFDC Range 126 XB100 Range 108

Related Products

GUV Range 124 PA Gland 152

Thomas & Betts • www.tnb-hazardous.com

Page 168: Catalog Thomas Betts

168

Index

Thomas & Betts • www.tnb-hazardous.com

B004 97

B005B 99

B006 99

B006L 99

B007 99

B008B 99

B009A 99

B010B 99

B011 99

B013 99

B013K 99

B014B 99

B015 99

B016 99

B017 99

BCP30 130

BCP40 130

BCP50 130

BP01 130

BP02 130

BP03 130

BP04 130

BP05 130

BP05V 130

BPN10 130

BPR10 130

BPV10 130

D002 96

D003 96

D004 96

D005 96

D006 96

D007 96

D008 96

D009 96

D010 96

D010PL 96

D011 96

D017 96

D018 96

D019 96

D020 96

D021 96

D021B 99

D022 96

D023 94

D024 94

D09E 96

DE01 130

DE02 130

DE03 130

DE04 130

DE05 130

DE10 130

E006 97

E007 97

E008 97

E009 97

EF110G-00000 77

EF110P-00000 77

EF140G-00000 77

EF140P-00000 77

EFDC21 127

EFDC21F 127

EFDC21G 127

EFDC21P 127

EFDC21V 127

EFDC22 127

EFDC23 127

EFDC23A 127

EFDC24 127

EFDC25 127

EFDC36 127

EFDC37 127

EFDC38 127

EFDC39 127

EFDC40 127

EFDC41 127

EFDC42 127

EFDC43 127

EFDC44 127

EJB0 129

EJB1 129

EJB11 129

EJB12 129

EJB13 129

EJB2 129

EJB4 129

EJB5 129

EJB8 129

EL120-0G000 75

EL220-0G000 75

EL30011-0G000 75

EL30028-0G000 75

EL3008-0G000 75

EL3009-0G000 75

ESB220-0000 49

ESB220-A000 49

ESB240-0000 49

ESB240-A000 49

ESB240EM-0000 69

ESB240EM-A000 69

ESB265-0000 49

ESB265-A000 49

EST220-00J0 81

EST220-A0J0 81

EST240-00J0 81

EST240-A0J0 81

EST240EM-00J0 93

EST240EM-A0J0 93

EST265-00J0 81

EST265-A0J0 81

EVD120-00J0 47

EVD120-A0J0 47

EVD120-B0J0 47

EVD120EM-00J0 65

EVD120EM-A0J0 65

EVD120EMA-A000 67

EVD120EM-B0J0 65

EVD140-00J0 47

EVD140-A0J0 47

EVD140-B0J0 47

EVD140EM-00J0 65

EVD140EM-A0J0 65

EVD140EMA-A000 67

EVD140EMA-B000 67

EVD140EM-B0J0 65

EVD165-00J0 47

EVD165-A0J0 47

EVD165-B0J0 47

EVD220-00J0 47

EVD220-A0J0 47

EVD220-B0J0 47

EVD220EM-00J0 65

EVD220EM-A0J0 65

EVD220EMA-A000 67

EVD220EM-B0J0 65

EVD240-00J0 47

EVD240-A0J0 47

EVD240-B0J0 47

EVD240EM-00J0 65

EVD240EM-A0J0 65

EVD240EMA-A000 67

EVD240EMA-B000 67

EVD240EM-B0J0 65

EVD265-00J0 47

EVD265-A0J0 47

EVD265-B0J0 47

EVN120-0000 45

EVN120-A000 45

EVN120-B000 45

EVN120EM-0000 61

EVN120EM-A000 61

EVN120EMA-A000 63

EVN120EM-B000 61

EVN140-0000 45

EVN140-A000 45

EVN140-B000 45

EVN140EM-0000 61

EVN140EM-A000 61

EVN140EMA-A000 63

EVN140EMA-B000 63

EVN140EM-B000 61

EVN165-0000 45

EVN165-A000 45

EVN165-B000 45

EVN220-0000 45

EVN220-A000 45

EVN220-B000 45

EVN220EM-0000 61

EVN220EM-A000 61

EVN220EMA-A000 63

EVN220EM-B000 61

EVN240-0000 45

EVN240-A000 45

EVN240-B000 45

EVN240EM-0000 61

EVN240EM-A000 61

EVN240EMA-A000 63

EVN240EMA-B000 63

EVN240EM-B000 61

EVN265-0000 45

EVN265-A000 45

EVN265-B000 45

EVS120-0000 43

EVS120-A000 43

EVS120-B000 43

EVS120EM-0000 57

EVS120EM-A000 57

EVS120EM-B000 57

EVS120EMEA-0000 59

EVS120EMEA-A000 59

EVS120EMEA-B000 59

EVS140-0000 43

EVS140-A000 43

EVS140-B000 43

EVS140EM-0000 57

EVS140EM-A000 57

EVS140EM-B000 57

EVS140EMEA-0000 59

EVS140EMEA-A000 59

EVS140EMEA-B000 59

EVS165-0000 43

EVS165-A000 43

EVS165-B000 43

EVS220-0000 43

EVS220-A000 43

EVS220-B000 43

EVS220EM-0000 57

EVS220EM-A000 57

EVS220EM-B000 57

EVS220EMA-0000 59

EVS220EMA-A000 59

EVS220EMA-B000 59

EVS240-0000 43

EVS240-A000 43

EVS240-B000 43

EVS240EM-0000 57

EVS240EM-A000 57

EVS240EM-B000 57

EVS240EMA-0000 59

EVS240EMA-A000 59

EVS240EMA-B000 59

EVS265-0000 43

EVS265-A000 43

EVS265-B000 43

EVT120-00J0 79

EVT120-A0J0 79

EVT120-B0J0 79

EVT120EM-00J0 89

EVT120EM-A0J0 89

EVT120EMA-A0J0 91

EVT120EM-B0J0 89

EVT140-00J0 79

EVT140-A0J0 79

EVT140-B0J0 79

EVT140EM-00J0 89

EVT140EM-A0J0 89

EVT140EMA-A0J0 91

EVT140EMA-B0J0 91

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 169: Catalog Thomas Betts

Index

169

Thomas & Betts • www.tnb-hazardous.com

EVT140EM-B0J0 89

EVT165-00J0 79

EVT165-A0J0 79

EVT165-B0J0 79

EVT220-00J0 79

EVT220-A0J0 79

EVT220-B0J0 79

EVT220EM-00J0 89

EVT220EM-A0J0 89

EVT220EMA-A0J0 91

EVT220EM-B0J0 89

EVT240-00J0 79

EVT240-A0J0 79

EVT240-B0J0 79

EVT240EM-00J0 89

EVT240EM-A0J0 89

EVT240EMA-A0J0 91

EVT240EMA-B0J0 91

EVT240EM-B0J0 89

EVT265-00J0 79

EVT265-A0J0 79

EVT265-B0J0 79

EVX100-00000 102

EVX200-00000 102

EVX300-00000 102

EVXlm40-00000 103

EVXlm40-00000 103

EVXNa20-00000 103

EVXNa30-00000 103

EVXNa40-00000 103

EVXNa50-00000 103

EX/038/SP 163

EX/038/TSP 163

EX/038-M16/TC 159

EX/050/SP 163

EX/050/TSP 163

EX/050-075/E 160

EX/050-M16/TC 159

EX/050-M20/TC 159

EX/050-M25/TC 159

EX/050-PG11/TC 161

EX/050-PG13/TC 161

EX/050-PG16/TC 161

EX/050-PG9/TC 161

EX/075/SP 163

EX/075/TSP 163

EX/075-050/R 160

EX/075-100/E 160

EX/075-M16/TC 159

EX/075-M20/TC 159

EX/075-M25/TC 159

EX/075-M32/TC 159

EX/075-PG11/TC 161

EX/075-PG13/TC 161

EX/075-PG16/TC 161

EX/075-PG21/TC 161

EX/075-PG9/TC 161

EX/100/SP 163

EX/100/TSP 163

EX/100-050/R 160

EX/100-075/R 160

EX/100-125/E 160

EX/100-M16/TC 159

EX/100-M20/TC 159

EX/100-M25/TC 159

EX/100-M32/TC 159

EX/100-M40/TC 159

EX/100-PG11/TC 161

EX/100-PG13/TC 161

EX/100-PG16/TC 161

EX/100-PG21/TC 161

EX/100-PG29/TC 161

EX/100-PG9/TC 161

EX/125/SP 163

EX/125/TSP 163

EX/125-050/R 160

EX/125-075/R 160

EX/125-100/R 160

EX/125-150/E 160

EX/125-M16/TC 159

EX/125-M20/TC 159

EX/125-M25/TC 159

EX/125-M32/TC 159

EX/125-M40/TC 159

EX/125-M50/TC 159

EX/125-PG11/TC 161

EX/125-PG13/TC 161

EX/125-PG16/TC 161

EX/125-PG21/TC 161

EX/125-PG29/TC 161

EX/125-PG36/TC 161

EX/125-PG9/TC 161

EX/150/SP 163

EX/150/TSP 163

EX/150-050/R 160

EX/150-075/R 160

EX/150-100/R 160

EX/150-125/R 160

EX/150-200/E 160

EX/150-M16/TC 159

EX/150-M20/TC 159

EX/150-M25/TC 159

EX/150-M32/TC 159

EX/150-M40/TC 159

EX/150-M50/TC 159

EX/150-M63/TC 159

EX/150-PG11/TC 161

EX/150-PG13/TC 161

EX/150-PG16/TC 161

EX/150-PG21/TC 161

EX/150-PG29/TC 161

EX/150-PG36/TC 161

EX/150-PG42/TC 161

EX/150-PG9/TC 161

EX/200/SP 163

EX/200/TSP 163

EX/200-050/R 160

EX/200-075/R 160

EX/200-100/R 160

EX/200-125/R 160

EX/200-150/R 160

EX/200-M16/TC 159

EX/200-M20/TC 159

EX/200-M25/TC 159

EX/200-M32/TC 159

EX/200-M40/TC 159

EX/200-M50/TC 159

EX/200-M63/TC 159

EX/200-PG11/TC 161

EX/200-PG13/TC 161

EX/200-PG16/TC 161

EX/200-PG21/TC 161

EX/200-PG29/TC 161

EX/200-PG36/TC 161

EX/200-PG42/TC 161

EX/200-PG48/TC 161

EX/200-PG9/TC 161

EX/250-M50/TC 159

EX/300-M50/TC 159

EX/M16/C 167

EX/M16/DSP 165

EX/M16/HSP 165

EX/M16/SP 163

EX/M16/TAG 167

EX/M16/TSP 163

EX/M16-038/TC 160

EX/M16-050/TC 160

EX/M16-M20/E 159

EX/M16-M25/E 159

EX/M16-PG11/TC 161

EX/M16-PG13/TC 161

EX/M16-PG9/TC 161

EX/M20/C 167

EX/M20/DSP 165

EX/M20/HSP 165

EX/M20/SP 163

EX/M20/TAG 167

EX/M20/TSP 163

EX/M20-050/TC 160

EX/M20-075/TC 160

EX/M20-M16/R 159

EX/M20-M25/E 159

EX/M20-M32/E 159

EX/M20-PG11/TC 161

EX/M20-PG13/TC 161

EX/M20-PG16/TC 161

EX/M20-PG9/TC 161

EX/M25/C 167

EX/M25/DSP 165

EX/M25/HSP 165

EX/M25/SP 163

EX/M25/TAG 167

EX/M25/TSP 163

EX/M25-050/TC 160

EX/M25-075/TC 160

EX/M25-100/TC 160

EX/M25-M16/R 159

EX/M25-M20/R 159

EX/M25-M32/E 159

EX/M25-M40/E 159

EX/M25-PG11/TC 161

EX/M25-PG13/TC 161

EX/M25-PG16/TC 161

EX/M25-PG21/TC 161

EX/M25-PG9/TC 161

EX/M32/C 167

EX/M32/DSP 165

EX/M32/HSP 165

EX/M32/SP 163

EX/M32/TAG 167

EX/M32/TSP 163

EX/M32-050/TC 160

EX/M32-075/TC 160

EX/M32-100/TC 160

EX/M32-125/TC 160

EX/M32-M16/R 159

EX/M32-M20/R 159

EX/M32-M25/R 159

EX/M32-M40/E 159

EX/M32-M50/E 159

EX/M32-PG11/TC 161

EX/M32-PG13/TC 161

EX/M32-PG16/TC 161

EX/M32-PG21/TC 161

EX/M32-PG29/TC 161

EX/M32-PG9/TC 161

EX/M40/C 167

EX/M40/DSP 165

EX/M40/HSP 165

EX/M40/SP 163

EX/M40/TAG 167

EX/M40/TSP 163

EX/M40-050/TC 160

EX/M40-075/TC 160

EX/M40-100/TC 160

EX/M40-125/TC 160

EX/M40-150/TC 160

EX/M40-M16/R 159

EX/M40-M20/R 159

EX/M40-M25/R 159

EX/M40-M32/R 159

EX/M40-M50/E 159

EX/M40-M63/E 159

EX/M40-PG11/TC 161

EX/M40-PG13/TC 161

EX/M40-PG16/TC 161

EX/M40-PG21/TC 161

EX/M40-PG29/TC 161

EX/M40-PG36/TC 161

EX/M40-PG9/TC 161

EX/M50/C 167

EX/M50/DSP 165

EX/M50/HSP 165

EX/M50/SP 163

EX/M50/TAG 167

EX/M50/TSP 163

EX/M50-050/TC 160

EX/M50-075/TC 160

EX/M50-100/TC 160

EX/M50-125/TC 160

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 170: Catalog Thomas Betts

170

Index

Thomas & Betts • www.tnb-hazardous.com

EX/M50-150/TC 160

EX/M50-200/TC 160

EX/M50-M16/R 159

EX/M50-M20/R 159

EX/M50-M25/R 159

EX/M50-M32/R 159

EX/M50-M40/R 159

EX/M50-M63/E 159

EX/M50-M75/E 159

EX/M50-PG11/TC 161

EX/M50-PG13/TC 161

EX/M50-PG16/TC 161

EX/M50-PG21/TC 161

EX/M50-PG29/TC 161

EX/M50-PG36/TC 161

EX/M50-PG42/TC 161

EX/M50-PG9/TC 161

EX/M63/C 167

EX/M63/DSP 165

EX/M63/HSP 165

EX/M63/SP 163

EX/M63/TAG 167

EX/M63/TSP 163

EX/M63-050/TC 160

EX/M63-075/TC 160

EX/M63-100/TC 160

EX/M63-125/TC 160

EX/M63-150/TC 160

EX/M63-200/TC 160

EX/M63-M16/R 159

EX/M63-M20/R 159

EX/M63-M25/R 159

EX/M63-M32/R 159

EX/M63-M40/R 159

EX/M63-M50/R 159

EX/M63-M75/E 159

EX/M63-PG11/TC 161

EX/M63-PG13/TC 161

EX/M63-PG16/TC 161

EX/M63-PG21/TC 161

EX/M63-PG29/TC 161

EX/M63-PG36/TC 161

EX/M63-PG42/TC 161

EX/M63-PG48/TC 161

EX/M63-PG9/TC 161

EX/M75/C 167

EX/M75/TAG 167

EX/M75-050/TC 160

EX/M75-075/TC 160

EX/M75-100/TC 160

EX/M75-125/TC 160

EX/M75-150/TC 160

EX/M75-200/TC 160

EX/M75-M16/R 159

EX/M75-M20/R 159

EX/M75-M25/R 159

EX/M75-M32/R 159

EX/M75-M40/R 159

EX/M75-M50/R 159

EX/M75-M63/R 159

EX/M75-PG11/TC 161

EX/M75-PG13/TC 161

EX/M75-PG16/TC 161

EX/M75-PG21/TC 161

EX/M75-PG29/TC 161

EX/M75-PG36/TC 161

EX/M75-PG42/TC 161

EX/M75-PG48/TC 161

EX/M75-PG9/TC 161

EX/PG11/DSP 165

EX/PG11/HSP 165

EX/PG11/SP 163

EX/PG11/TSP 163

EX/PG11-050/TC 160

EX/PG11-M16/TC 159

EX/PG11-M20/TC 159

EX/PG11-PG9/R 161

EX/PG13/DSP 165

EX/PG13/HSP 165

EX/PG13/SP 163

EX/PG13/TSP 163

EX/PG13-050/TC 160

EX/PG13-M16/TC 159

EX/PG13-M20/TC 159

EX/PG13-PG11/R 161

EX/PG13-PG9/R 161

EX/PG16/DSP 165

EX/PG16/HSP 165

EX/PG16/SP 163

EX/PG16/TSP 163

EX/PG16-050/TC 160

EX/PG16-075/TC 160

EX/PG16-M16/TC 159

EX/PG16-M20/TC 159

EX/PG16-M25/TC 159

EX/PG16-PG11/R 161

EX/PG16-PG13/R 161

EX/PG16-PG21/E 161

EX/PG16-PG9/R 161

EX/PG21/DSP 165

EX/PG21/HSP 165

EX/PG21/SP 163

EX/PG21/TSP 163

EX/PG21-075/TC 160

EX/PG21-100/TC 160

EX/PG21-M16/TC 159

EX/PG21-M20/TC 159

EX/PG21-M25/TC 159

EX/PG21-M32/TC 159

EX/PG21-PG11/R 161

EX/PG21-PG13/R 161

EX/PG21-PG16/R 161

EX/PG21-PG29/E 161

EX/PG21-PG9/R 161

EX/PG29/DSP 165

EX/PG29/HSP 165

EX/PG29/SP 163

EX/PG29/TSP 163

EX/PG29-050/TC 160

EX/PG29-075/TC 160

EX/PG29-100/TC 160

EX/PG29-125/TC 160

EX/PG29-150/TC 160

EX/PG29-M16/TC 159

EX/PG29-M20/TC 159

EX/PG29-M25/TC 159

EX/PG29-M32/TC 159

EX/PG29-M40/TC 159

EX/PG29-PG11/R 161

EX/PG29-PG13/R 161

EX/PG29-PG16/R 161

EX/PG29-PG21/R 161

EX/PG29-PG36/E 161

EX/PG29-PG9/R 161

EX/PG36/DSP 165

EX/PG36/HSP 165

EX/PG36/SP 163

EX/PG36/TSP 163

EX/PG36-050/TC 160

EX/PG36-075/TC 160

EX/PG36-100/TC 160

EX/PG36-125/TC 160

EX/PG36-150/TC 160

EX/PG36-M16/TC 159

EX/PG36-M20/TC 159

EX/PG36-M25/TC 159

EX/PG36-M32/TC 159

EX/PG36-M40/TC 159

EX/PG36-M50/TC 159

EX/PG36-PG11/R 161

EX/PG36-PG13/R 161

EX/PG36-PG16/R 161

EX/PG36-PG21/R 161

EX/PG36-PG29/R 161

EX/PG36-PG48/E 161

EX/PG36-PG9/R 161

EX/PG42/DSP 165

EX/PG42/HSP 165

EX/PG42/SP 163

EX/PG42/TSP 163

EX/PG42-050/TC 160

EX/PG42-075/TC 160

EX/PG42-100/TC 160

EX/PG42-125/TC 160

EX/PG42-150/TC 160

EX/PG42-200/TC 160

EX/PG42-M16/TC 159

EX/PG42-M20/TC 159

EX/PG42-M25/TC 159

EX/PG42-M32/TC 159

EX/PG42-M40/TC 159

EX/PG42-M50/TC 159

EX/PG42-M63/TC 159

EX/PG42-PG11/R 161

EX/PG42-PG13/R 161

EX/PG42-PG16/R 161

EX/PG42-PG21/R 161

EX/PG42-PG29/R 161

EX/PG42-PG36/R 161

EX/PG42-PG48/E 161

EX/PG42-PG9/R 161

EX/PG48/DSP 165

EX/PG48/HSP 165

EX/PG48/SP 163

EX/PG48/TSP 163

EX/PG48-050/TC 160

EX/PG48-075/TC 160

EX/PG48-100/TC 160

EX/PG48-125/TC 160

EX/PG48-150/TC 160

EX/PG48-200/TC 160

EX/PG48-M16/TC 159

EX/PG48-M20/TC 159

EX/PG48-M25/TC 159

EX/PG48-M32/TC 159

EX/PG48-M40/TC 159

EX/PG48-M50/TC 159

EX/PG48-M63/TC 159

EX/PG48-PG11/R 161

EX/PG48-PG13/R 161

EX/PG48-PG16/R 161

EX/PG48-PG21/R 161

EX/PG48-PG29/R 161

EX/PG48-PG36/R 161

EX/PG48-PG42/R 161

EX/PG48-PG9/R 161

EX/PG9/DSP 165

EX/PG9/HSP 165

EX/PG9/SP 163

EX/PG9/TSP 163

EX/PG9-050/TC 160

EX/PG9-M16/TC 159

EX/PG9-M20/TC 159

EX-8160 167

EX-8240 167

EX-8560 167

EX-8640 167

EX-8720 167

EX-8800 167

EXB0310 137

EXB0330 137

EXB0350 137

EXB0410 137

EXB0430 137

EXB0450 137

EXB0510 137

EXB0530 137

EXB0550 137

EXB0610 137

EXB0630 137

EXB0650 137

EXB0710 137

EXB0730 137

EXB0750 137

EXB0810 137

EXB0830 137

EXB0850 137

EXBB0310 137

EXBB0410 137

EXBB0430 137

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 171: Catalog Thomas Betts

Index

171

Thomas & Betts • www.tnb-hazardous.com

EXBB0450 137

EXBB0510 137

EXBB0530 137

EXBB0550 137

EXBB0610 137

EXBB0630 137

EXBB0650 137

EXBB0710 137

EXBB0810 137

EXBBT0110 141

EXBBT0130 141

EXBBT0210 141

EXBBT0230 141

EXBBT0310 141

EXBBT0330 141

EXBBT0410 141

EXBBT0430 141

EXBBT0450 141

EXBBT0510 141

EXBBT0530 141

EXBBT0550 141

EXBBT0610 141

EXBBT0630 141

EXBBT0710 141

EXBBT0720 141

EXBBT0810 141

EXBBT0820 141

EXBBT0910 141

EXBBT0920 141

EXBQA0304 139

EXBQA0404 139

EXBQA0505 139

EXBQA0606 139

EXBQA0707 139

EXBQA0808 139

EXBQM0303 139

EXBQM0404 139

EXBQM0505 139

EXBQM0606 139

EXBQM0707 139

EXBQM0808 139

EXFM03 167

EXFM03F 167

EXFM04 167

EXFM04F 167

EXFM05 167

EXFM05F 167

EXFM06 167

EXFM06F 167

EXFM07 167

EXFM07F 167

EXFM08 167

EXFM08F 167

EXLB0110 141

EXLB0130 141

EXLB0210 141

EXLB0230 141

EXLB0310 141

EXLB0330 141

EXLB0410 141

EXLB0430 141

EXLB0450 141

EXLB0510 141

EXLB0530 141

EXLB0550 141

EXLB0610 141

EXLB0630 141

EXLB0710 141

EXLB0720 141

EXLB0810 141

EXLB0820 141

EXLB0910 141

EXLB0920 141

EXLH0310 141

EXLH0330 141

EXLH0410 141

EXLH0430 141

EXLH0510 141

EXLH0530 141

EXLH0610 141

EXLH0620 141

EXLH0710 141

EXLH0720 141

EXLH0810 141

EXLH0820 141

EXLH0910 141

EXLH0920 141

EXLHC0310 141

EXLHC0330 141

EXLHC0410 141

EXLHC0430 141

EXLHC0510 141

EXLHC0530 141

EXLHC0610 141

EXLHC0630 141

EXLHC0710 141

EXLHC0810 141

EXLHC0820 141

EXLHC0910 141

EXLLH0310 141

EXLLH0330 141

EXLLH0410 141

EXLLH0430 141

EXLLH0510 141

EXLLH0530 141

EXLLH0610 141

EXLLH0620 141

EXLLH0710 141

EXLLH0720 141

EXLLH0810 141

EXLLH0820 141

EXLLH0910 141

EXLLH0920 141

EXLT0310 141

EXLT0330 141

EXLT0410 141

EXLT0430 141

EXLT0510 141

EXLT0530 141

EXLT0610 141

EXLT0620 141

EXLT0710 141

EXLT0720 141

EXLT0810 141

EXLT0820 141

EXLT0910 141

EXLT0920 141

EXLT0930 141

EX-M16 165

EX-M20 165

EX-M25 165

EX-M32 165

EX-M40 165

EX-M50 165

EX-M63 165

EXN/038/SP 163

EXN/038/TSP 163

EXN/038-M16/TC 159

EXN/050/SP 163

EXN/050/TSP 163

EXN/050-075/E 160

EXN/050-M16/TC 159

EXN/050-M20/TC 159

EXN/050-M25/TC 159

EXN/050-PG11/TC 161

EXN/050-PG13/TC 161

EXN/050-PG16/TC 161

EXN/050-PG9/TC 161

EXN/075/SP 163

EXN/075/TSP 163

EXN/075-050/R 160

EXN/075-100/E 160

EXN/075-M16/TC 159

EXN/075-M20/TC 159

EXN/075-M25/TC 159

EXN/075-M32/TC 159

EXN/075-PG11/TC 161

EXN/075-PG13/TC 161

EXN/075-PG16/TC 161

EXN/075-PG21/TC 161

EXN/075-PG9/TC 161

EXN/100/SP 163

EXN/100/TSP 163

EXN/100-050/R 160

EXN/100-075/R 160

EXN/100-125/E 160

EXN/100-M16/TC 159

EXN/100-M20/TC 159

EXN/100-M25/TC 159

EXN/100-M32/TC 159

EXN/100-M40/TC 159

EXN/100-PG11/TC 161

EXN/100-PG13/TC 161

EXN/100-PG16/TC 161

EXN/100-PG21/TC 161

EXN/100-PG29/TC 161

EXN/100-PG9/TC 161

EXN/125/SP 163

EXN/125/TSP 163

EXN/125-050/R 160

EXN/125-075/R 160

EXN/125-100/R 160

EXN/125-150/E 160

EXN/125-M16/TC 159

EXN/125-M20/TC 159

EXN/125-M25/TC 159

EXN/125-M32/TC 159

EXN/125-M40/TC 159

EXN/125-M50/TC 159

EXN/125-PG11/TC 161

EXN/125-PG13/TC 161

EXN/125-PG16/TC 161

EXN/125-PG21/TC 161

EXN/125-PG29/TC 161

EXN/125-PG36/TC 161

EXN/125-PG9/TC 161

EXN/150/SP 163

EXN/150/TSP 163

EXN/150-050/R 160

EXN/150-075/R 160

EXN/150-100/R 160

EXN/150-125/R 160

EXN/150-200/E 160

EXN/150-M16/TC 159

EXN/150-M20/TC 159

EXN/150-M25/TC 159

EXN/150-M32/TC 159

EXN/150-M40/TC 159

EXN/150-M50/TC 159

EXN/150-M63/TC 159

EXN/150-PG11/TC 161

EXN/150-PG13/TC 161

EXN/150-PG16/TC 161

EXN/150-PG21/TC 161

EXN/150-PG29/TC 161

EXN/150-PG36/TC 161

EXN/150-PG42/TC 161

EXN/150-PG9/TC 161

EXN/200/SP 163

EXN/200/TSP 163

EXN/200-050/R 160

EXN/200-075/R 160

EXN/200-100/R 160

EXN/200-125/R 160

EXN/200-150/R 160

EXN/200-M16/TC 159

EXN/200-M20/TC 159

EXN/200-M25/TC 159

EXN/200-M32/TC 159

EXN/200-M40/TC 159

EXN/200-M50/TC 159

EXN/200-M63/TC 159

EXN/200-PG11/TC 161

EXN/200-PG13/TC 161

EXN/200-PG16/TC 161

EXN/200-PG21/TC 161

EXN/200-PG29/TC 161

EXN/200-PG36/TC 161

EXN/200-PG42/TC 161

EXN/200-PG48/TC 161

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 172: Catalog Thomas Betts

172

Index

Thomas & Betts • www.tnb-hazardous.com

EXN/200-PG9/TC 161

EXN/250-M50/TC 159

EXN/300-M50/TC 159

EXN/M16/C 167

EXN/M16/DSP 165

EXN/M16/HSP 165

EXN/M16/SP 163

EXN/M16/TSP 163

EXN/M16-038/TC 160

EXN/M16-050/TC 160

EXN/M16-M20/E 159

EXN/M16-M25/E 159

EXN/M16-PG11/TC 161

EXN/M16-PG13/TC 161

EXN/M16-PG9/TC 161

EXN/M20/C 167

EXN/M20/DSP 165

EXN/M20/HSP 165

EXN/M20/SP 163

EXN/M20/TSP 163

EXN/M20-050/TC 160

EXN/M20-075/TC 160

EXN/M20-M16/R 159

EXN/M20-M25/E 159

EXN/M20-M32/E 159

EXN/M20-PG11/TC 161

EXN/M20-PG13/TC 161

EXN/M20-PG16/TC 161

EXN/M20-PG9/TC 161

EXN/M25/C 167

EXN/M25/DSP 165

EXN/M25/HSP 165

EXN/M25/SP 163

EXN/M25/TSP 163

EXN/M25-050/TC 160

EXN/M25-075/TC 160

EXN/M25-100/TC 160

EXN/M25-M16/R 159

EXN/M25-M20/R 159

EXN/M25-M32/E 159

EXN/M25-M40/E 159

EXN/M25-PG11/TC 161

EXN/M25-PG13/TC 161

EXN/M25-PG16/TC 161

EXN/M25-PG21/TC 161

EXN/M25-PG9/TC 161

EXN/M32/C 167

EXN/M32/DSP 165

EXN/M32/HSP 165

EXN/M32/SP 163

EXN/M32/TSP 163

EXN/M32-050/TC 160

EXN/M32-075/TC 160

EXN/M32-100/TC 160

EXN/M32-125/TC 160

EXN/M32-M16/R 159

EXN/M32-M20/R 159

EXN/M32-M25/R 159

EXN/M32-M40/E 159

EXN/M32-M50/E 159

EXN/M32-PG11/TC 161

EXN/M32-PG13/TC 161

EXN/M32-PG16/TC 161

EXN/M32-PG21/TC 161

EXN/M32-PG29/TC 161

EXN/M32-PG9/TC 161

EXN/M40/C 167

EXN/M40/DSP 165

EXN/M40/HSP 165

EXN/M40/SP 163

EXN/M40/TSP 163

EXN/M40-050/TC 160

EXN/M40-075/TC 160

EXN/M40-100/TC 160

EXN/M40-125/TC 160

EXN/M40-150/TC 160

EXN/M40-M16/R 159

EXN/M40-M20/R 159

EXN/M40-M25/R 159

EXN/M40-M32/R 159

EXN/M40-M50/E 159

EXN/M40-M63/E 159

EXN/M40-PG11/TC 161

EXN/M40-PG13/TC 161

EXN/M40-PG16/TC 161

EXN/M40-PG21/TC 161

EXN/M40-PG29/TC 161

EXN/M40-PG36/TC 161

EXN/M40-PG9/TC 161

EXN/M50/C 167

EXN/M50/DSP 165

EXN/M50/HSP 165

EXN/M50/SP 163

EXN/M50/TSP 163

EXN/M50-050/TC 160

EXN/M50-075/TC 160

EXN/M50-100/TC 160

EXN/M50-125/TC 160

EXN/M50-150/TC 160

EXN/M50-200/TC 160

EXN/M50-M16/R 159

EXN/M50-M20/R 159

EXN/M50-M25/R 159

EXN/M50-M32/R 159

EXN/M50-M40/R 159

EXN/M50-M63/E 159

EXN/M50-M75/E 159

EXN/M50-PG11/TC 161

EXN/M50-PG13/TC 161

EXN/M50-PG16/TC 161

EXN/M50-PG21/TC 161

EXN/M50-PG29/TC 161

EXN/M50-PG36/TC 161

EXN/M50-PG42/TC 161

EXN/M50-PG9/TC 161

EXN/M63/C 167

EXN/M63/DSP 165

EXN/M63/HSP 165

EXN/M63/SP 163

EXN/M63/TSP 163

EXN/M63-050/TC 160

EXN/M63-075/TC 160

EXN/M63-100/TC 160

EXN/M63-125/TC 160

EXN/M63-150/TC 160

EXN/M63-200/TC 160

EXN/M63-M16/R 159

EXN/M63-M20/R 159

EXN/M63-M25/R 159

EXN/M63-M32/R 159

EXN/M63-M40/R 159

EXN/M63-M50/R 159

EXN/M63-M75/E 159

EXN/M63-PG11/TC 161

EXN/M63-PG13/TC 161

EXN/M63-PG16/TC 161

EXN/M63-PG21/TC 161

EXN/M63-PG29/TC 161

EXN/M63-PG36/TC 161

EXN/M63-PG42/TC 161

EXN/M63-PG48/TC 161

EXN/M63-PG9/TC 161

EXN/M75-050/TC 160

EXN/M75-075/TC 160

EXN/M75-100/TC 160

EXN/M75-125/TC 160

EXN/M75-150/TC 160

EXN/M75-200/TC 160

EXN/M75-M16/R 159

EXN/M75-M20/R 159

EXN/M75-M25/R 159

EXN/M75-M32/R 159

EXN/M75-M40/R 159

EXN/M75-M50/R 159

EXN/M75-M63/R 159

EXN/M75-PG11/TC 161

EXN/M75-PG13/TC 161

EXN/M75-PG16/TC 161

EXN/M75-PG21/TC 161

EXN/M75-PG29/TC 161

EXN/M75-PG36/TC 161

EXN/M75-PG42/TC 161

EXN/M75-PG48/TC 161

EXN/M75-PG9/TC 161

EXN/PG11/DSP 165

EXN/PG11/HSP 165

EXN/PG11/SP 163

EXN/PG11/TSP 163

EXN/PG11-050/TC 160

EXN/PG11-M16/TC 159

EXN/PG11-M20/TC 159

EXN/PG11-PG9/R 161

EXN/PG13/DSP 165

EXN/PG13/HSP 165

EXN/PG13/SP 163

EXN/PG13/TSP 163

EXN/PG13-050/TC 160

EXN/PG13-M16/TC 159

EXN/PG13-M20/TC 159

EXN/PG13-PG11/R 161

EXN/PG13-PG9/R 161

EXN/PG16/DSP 165

EXN/PG16/HSP 165

EXN/PG16/SP 163

EXN/PG16/TSP 163

EXN/PG16-050/TC 160

EXN/PG16-075/TC 160

EXN/PG16-M16/TC 159

EXN/PG16-M20/TC 159

EXN/PG16-M25/TC 159

EXN/PG16-PG11/R 161

EXN/PG16-PG13/R 161

EXN/PG16-PG21/E 161

EXN/PG16-PG9/R 161

EXN/PG21/DSP 165

EXN/PG21/HSP 165

EXN/PG21/SP 163

EXN/PG21/TSP 163

EXN/PG21-075/TC 160

EXN/PG21-100/TC 160

EXN/PG21-M16/TC 159

EXN/PG21-M20/TC 159

EXN/PG21-M25/TC 159

EXN/PG21-M32/TC 159

EXN/PG21-PG11/R 161

EXN/PG21-PG13/R 161

EXN/PG21-PG16/R 161

EXN/PG21-PG29/E 161

EXN/PG21-PG9/R 161

EXN/PG29/DSP 165

EXN/PG29/HSP 165

EXN/PG29/SP 163

EXN/PG29/TSP 163

EXN/PG29-050/TC 160

EXN/PG29-075/TC 160

EXN/PG29-100/TC 160

EXN/PG29-125/TC 160

EXN/PG29-150/TC 160

EXN/PG29-M16/TC 159

EXN/PG29-M20/TC 159

EXN/PG29-M25/TC 159

EXN/PG29-M32/TC 159

EXN/PG29-M40/TC 159

EXN/PG29-PG11/R 161

EXN/PG29-PG13/R 161

EXN/PG29-PG16/R 161

EXN/PG29-PG21/R 161

EXN/PG29-PG36/E 161

EXN/PG29-PG9/R 161

EXN/PG36/DSP 165

EXN/PG36/HSP 165

EXN/PG36/SP 163

EXN/PG36/TSP 163

EXN/PG36-050/TC 160

EXN/PG36-075/TC 160

EXN/PG36-100/TC 160

EXN/PG36-125/TC 160

EXN/PG36-150/TC 160

EXN/PG36-M16/TC 159

EXN/PG36-M20/TC 159

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 173: Catalog Thomas Betts

Index

173

Thomas & Betts • www.tnb-hazardous.com

EXN/PG36-M25/TC 159

EXN/PG36-M32/TC 159

EXN/PG36-M40/TC 159

EXN/PG36-M50/TC 159

EXN/PG36-PG11/R 161

EXN/PG36-PG13/R 161

EXN/PG36-PG16/R 161

EXN/PG36-PG21/R 161

EXN/PG36-PG29/R 161

EXN/PG36-PG48/E 161

EXN/PG36-PG9/R 161

EXN/PG42/DSP 165

EXN/PG42/HSP 165

EXN/PG42/SP 163

EXN/PG42/TSP 163

EXN/PG42-050/TC 160

EXN/PG42-075/TC 160

EXN/PG42-100/TC 160

EXN/PG42-125/TC 160

EXN/PG42-150/TC 160

EXN/PG42-200/TC 160

EXN/PG42-M16/TC 159

EXN/PG42-M20/TC 159

EXN/PG42-M25/TC 159

EXN/PG42-M32/TC 159

EXN/PG42-M40/TC 159

EXN/PG42-M50/TC 159

EXN/PG42-M63/TC 159

EXN/PG42-PG11/R 161

EXN/PG42-PG13/R 161

EXN/PG42-PG16/R 161

EXN/PG42-PG21/R 161

EXN/PG42-PG29/R 161

EXN/PG42-PG36/R 161

EXN/PG42-PG48/E 161

EXN/PG42-PG9/R 161

EXN/PG48/DSP 165

EXN/PG48/HSP 165

EXN/PG48/SP 163

EXN/PG48/TSP 163

EXN/PG48-050/TC 160

EXN/PG48-075/TC 160

EXN/PG48-100/TC 160

EXN/PG48-125/TC 160

EXN/PG48-150/TC 160

EXN/PG48-200/TC 160

EXN/PG48-M16/TC 159

EXN/PG48-M20/TC 159

EXN/PG48-M25/TC 159

EXN/PG48-M32/TC 159

EXN/PG48-M40/TC 159

EXN/PG48-M50/TC 159

EXN/PG48-M63/TC 159

EXN/PG48-PG11/R 161

EXN/PG48-PG13/R 161

EXN/PG48-PG16/R 161

EXN/PG48-PG21/R 161

EXN/PG48-PG29/R 161

EXN/PG48-PG36/R 161

EXN/PG48-PG42/R 161

EXN/PG48-PG9/R 161

EXN/PG9/DSP 165

EXN/PG9/HSP 165

EXN/PG9/SP 163

EXN/PG9/TSP 163

EXN/PG9-050/TC 160

EXN/PG9-M16/TC 159

EXN/PG9-M20/TC 159

EXPQA0303 139

EXPQA0404 139

EXPQA0505 139

EXPQA0606 139

EXPQA0707 139

EXPQA0808 139

EXPQM0303 139

EXPQM0404 139

EXPQM0505 139

EXPQM0606 139

EXPQM0707 139

EXPQM0808 139

EXS/038/SP 163

EXS/038/TSP 163

EXS/038-M16/TC 159

EXS/050/SP 163

EXS/050/TSP 163

EXS/050-075/E 160

EXS/050-M16/TC 159

EXS/050-M20/TC 159

EXS/050-M25/TC 159

EXS/050-PG11/TC 161

EXS/050-PG13/TC 161

EXS/050-PG16/TC 161

EXS/050-PG9/TC 161

EXS/075/SP 163

EXS/075/TSP 163

EXS/075-050/R 160

EXS/075-100/E 160

EXS/075-M16/TC 159

EXS/075-M20/TC 159

EXS/075-M25/TC 159

EXS/075-M32/TC 159

EXS/075-PG11/TC 161

EXS/075-PG13/TC 161

EXS/075-PG16/TC 161

EXS/075-PG21/TC 161

EXS/075-PG9/TC 161

EXS/100/SP 163

EXS/100/TSP 163

EXS/100-050/R 160

EXS/100-075/R 160

EXS/100-125/E 160

EXS/100-M16/TC 159

EXS/100-M20/TC 159

EXS/100-M25/TC 159

EXS/100-M32/TC 159

EXS/100-M40/TC 159

EXS/100-PG11/TC 161

EXS/100-PG13/TC 161

EXS/100-PG16/TC 161

EXS/100-PG21/TC 161

EXS/100-PG29/TC 161

EXS/100-PG9/TC 161

EXS/125/SP 163

EXS/125/TSP 163

EXS/125-050/R 160

EXS/125-075/R 160

EXS/125-100/R 160

EXS/125-150/E 160

EXS/125-M16/TC 159

EXS/125-M20/TC 159

EXS/125-M25/TC 159

EXS/125-M32/TC 159

EXS/125-M40/TC 159

EXS/125-M50/TC 159

EXS/125-PG11/TC 161

EXS/125-PG13/TC 161

EXS/125-PG16/TC 161

EXS/125-PG21/TC 161

EXS/125-PG29/TC 161

EXS/125-PG36/TC 161

EXS/125-PG9/TC 161

EXS/150/SP 163

EXS/150/TSP 163

EXS/150-050/R 160

EXS/150-075/R 160

EXS/150-100/R 160

EXS/150-125/R 160

EXS/150-200/E 160

EXS/150-M16/TC 159

EXS/150-M20/TC 159

EXS/150-M25/TC 159

EXS/150-M32/TC 159

EXS/150-M40/TC 159

EXS/150-M50/TC 159

EXS/150-M63/TC 159

EXS/150-PG11/TC 161

EXS/150-PG13/TC 161

EXS/150-PG16/TC 161

EXS/150-PG21/TC 161

EXS/150-PG29/TC 161

EXS/150-PG36/TC 161

EXS/150-PG42/TC 161

EXS/150-PG9/TC 161

EXS/200/SP 163

EXS/200/TSP 163

EXS/200-050/R 160

EXS/200-075/R 160

EXS/200-100/R 160

EXS/200-125/R 160

EXS/200-150/R 160

EXS/200-M16/TC 159

EXS/200-M20/TC 159

EXS/200-M25/TC 159

EXS/200-M32/TC 159

EXS/200-M40/TC 159

EXS/200-M50/TC 159

EXS/200-M63/TC 159

EXS/200-PG11/TC 161

EXS/200-PG13/TC 161

EXS/200-PG16/TC 161

EXS/200-PG21/TC 161

EXS/200-PG29/TC 161

EXS/200-PG36/TC 161

EXS/200-PG42/TC 161

EXS/200-PG48/TC 161

EXS/200-PG9/TC 161

EXS/250-M50/TC 159

EXS/300-M50/TC 159

EXS/M16/C 167

EXS/M16/DSP 165

EXS/M16/HSP 165

EXS/M16/SP 163

EXS/M16/TSP 163

EXS/M16-038/TC 160

EXS/M16-050/TC 160

EXS/M16-M20/E 159

EXS/M16-M25/E 159

EXS/M16-PG11/TC 161

EXS/M16-PG13/TC 161

EXS/M16-PG9/TC 161

EXS/M20/C 167

EXS/M20/DSP 165

EXS/M20/HSP 165

EXS/M20/SP 163

EXS/M20/TSP 163

EXS/M20-050/TC 160

EXS/M20-075/TC 160

EXS/M20-M16/R 159

EXS/M20-M25/E 159

EXS/M20-M32/E 159

EXS/M20-PG11/TC 161

EXS/M20-PG13/TC 161

EXS/M20-PG16/TC 161

EXS/M20-PG9/TC 161

EXS/M25/C 167

EXS/M25/DSP 165

EXS/M25/HSP 165

EXS/M25/SP 163

EXS/M25/TSP 163

EXS/M25-050/TC 160

EXS/M25-075/TC 160

EXS/M25-100/TC 160

EXS/M25-M16/R 159

EXS/M25-M20/R 159

EXS/M25-M32/E 159

EXS/M25-M40/E 159

EXS/M25-PG11/TC 161

EXS/M25-PG13/TC 161

EXS/M25-PG16/TC 161

EXS/M25-PG21/TC 161

EXS/M25-PG9/TC 161

EXS/M32/C 167

EXS/M32/DSP 165

EXS/M32/HSP 165

EXS/M32/SP 163

EXS/M32/TSP 163

EXS/M32-050/TC 160

EXS/M32-075/TC 160

EXS/M32-100/TC 160

EXS/M32-125/TC 160

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 174: Catalog Thomas Betts

174

Index

Thomas & Betts • www.tnb-hazardous.com

EXS/M32-M16/R 159

EXS/M32-M20/R 159

EXS/M32-M25/R 159

EXS/M32-M40/E 159

EXS/M32-M50/E 159

EXS/M32-PG11/TC 161

EXS/M32-PG13/TC 161

EXS/M32-PG16/TC 161

EXS/M32-PG21/TC 161

EXS/M32-PG29/TC 161

EXS/M32-PG9/TC 161

EXS/M40/C 167

EXS/M40/DSP 165

EXS/M40/HSP 165

EXS/M40/SP 163

EXS/M40/TSP 163

EXS/M40-050/TC 160

EXS/M40-075/TC 160

EXS/M40-100/TC 160

EXS/M40-125/TC 160

EXS/M40-150/TC 160

EXS/M40-M16/R 159

EXS/M40-M20/R 159

EXS/M40-M25/R 159

EXS/M40-M32/R 159

EXS/M40-M50/E 159

EXS/M40-M63/E 159

EXS/M40-PG11/TC 161

EXS/M40-PG13/TC 161

EXS/M40-PG16/TC 161

EXS/M40-PG21/TC 161

EXS/M40-PG29/TC 161

EXS/M40-PG36/TC 161

EXS/M40-PG9/TC 161

EXS/M50/C 167

EXS/M50/DSP 165

EXS/M50/HSP 165

EXS/M50/SP 163

EXS/M50/TSP 163

EXS/M50-050/TC 160

EXS/M50-075/TC 160

EXS/M50-100/TC 160

EXS/M50-125/TC 160

EXS/M50-150/TC 160

EXS/M50-200/TC 160

EXS/M50-M16/R 159

EXS/M50-M20/R 159

EXS/M50-M25/R 159

EXS/M50-M32/R 159

EXS/M50-M40/R 159

EXS/M50-M63/E 159

EXS/M50-M75/E 159

EXS/M50-PG11/TC 161

EXS/M50-PG13/TC 161

EXS/M50-PG16/TC 161

EXS/M50-PG21/TC 161

EXS/M50-PG29/TC 161

EXS/M50-PG36/TC 161

EXS/M50-PG42/TC 161

EXS/M50-PG9/TC 161

EXS/M63/C 167

EXS/M63/DSP 165

EXS/M63/HSP 165

EXS/M63/SP 163

EXS/M63/TSP 163

EXS/M63-050/TC 160

EXS/M63-075/TC 160

EXS/M63-100/TC 160

EXS/M63-125/TC 160

EXS/M63-150/TC 160

EXS/M63-200/TC 160

EXS/M63-M16/R 159

EXS/M63-M20/R 159

EXS/M63-M25/R 159

EXS/M63-M32/R 159

EXS/M63-M40/R 159

EXS/M63-M50/R 159

EXS/M63-M75/E 159

EXS/M63-PG11/TC 161

EXS/M63-PG13/TC 161

EXS/M63-PG16/TC 161

EXS/M63-PG21/TC 161

EXS/M63-PG29/TC 161

EXS/M63-PG36/TC 161

EXS/M63-PG42/TC 161

EXS/M63-PG48/TC 161

EXS/M63-PG9/TC 161

EXS/M75-050/TC 160

EXS/M75-075/TC 160

EXS/M75-100/TC 160

EXS/M75-125/TC 160

EXS/M75-150/TC 160

EXS/M75-200/TC 160

EXS/M75-M16/R 159

EXS/M75-M20/R 159

EXS/M75-M25/R 159

EXS/M75-M32/R 159

EXS/M75-M40/R 159

EXS/M75-M50/R 159

EXS/M75-M63/R 159

EXS/M75-PG11/TC 161

EXS/M75-PG13/TC 161

EXS/M75-PG16/TC 161

EXS/M75-PG21/TC 161

EXS/M75-PG29/TC 161

EXS/M75-PG36/TC 161

EXS/M75-PG42/TC 161

EXS/M75-PG48/TC 161

EXS/M75-PG9/TC 161

EXS/PG11/DSP 165

EXS/PG11/HSP 165

EXS/PG11/SP 163

EXS/PG11/TSP 163

EXS/PG11-050/TC 160

EXS/PG11-M16/TC 159

EXS/PG11-M20/TC 159

EXS/PG11-PG9/R 161

EXS/PG13/DSP 165

EXS/PG13/HSP 165

EXS/PG13/SP 163

EXS/PG13/TSP 163

EXS/PG13-050/TC 160

EXS/PG13-M16/TC 159

EXS/PG13-M20/TC 159

EXS/PG13-PG11/R 161

EXS/PG13-PG9/R 161

EXS/PG16/DSP 165

EXS/PG16/HSP 165

EXS/PG16/SP 163

EXS/PG16/TSP 163

EXS/PG16-050/TC 160

EXS/PG16-075/TC 160

EXS/PG16-M16/TC 159

EXS/PG16-M20/TC 159

EXS/PG16-M25/TC 159

EXS/PG16-PG11/R 161

EXS/PG16-PG13/R 161

EXS/PG16-PG21/E 161

EXS/PG16-PG9/R 161

EXS/PG21/DSP 165

EXS/PG21/HSP 165

EXS/PG21/SP 163

EXS/PG21/TSP 163

EXS/PG21-075/TC 160

EXS/PG21-100/TC 160

EXS/PG21-M16/TC 159

EXS/PG21-M20/TC 159

EXS/PG21-M25/TC 159

EXS/PG21-M32/TC 159

EXS/PG21-PG11/R 161

EXS/PG21-PG13/R 161

EXS/PG21-PG16/R 161

EXS/PG21-PG29/E 161

EXS/PG21-PG9/R 161

EXS/PG29/DSP 165

EXS/PG29/HSP 165

EXS/PG29/SP 163

EXS/PG29/TSP 163

EXS/PG29-050/TC 160

EXS/PG29-075/TC 160

EXS/PG29-100/TC 160

EXS/PG29-125/TC 160

EXS/PG29-150/TC 160

EXS/PG29-M16/TC 159

EXS/PG29-M20/TC 159

EXS/PG29-M25/TC 159

EXS/PG29-M32/TC 159

EXS/PG29-M40/TC 159

EXS/PG29-PG11/R 161

EXS/PG29-PG13/R 161

EXS/PG29-PG16/R 161

EXS/PG29-PG21/R 161

EXS/PG29-PG36/E 161

EXS/PG29-PG9/R 161

EXS/PG36/DSP 165

EXS/PG36/HSP 165

EXS/PG36/SP 163

EXS/PG36/TSP 163

EXS/PG36-050/TC 160

EXS/PG36-075/TC 160

EXS/PG36-100/TC 160

EXS/PG36-125/TC 160

EXS/PG36-150/TC 160

EXS/PG36-M16/TC 159

EXS/PG36-M20/TC 159

EXS/PG36-M25/TC 159

EXS/PG36-M32/TC 159

EXS/PG36-M40/TC 159

EXS/PG36-M50/TC 159

EXS/PG36-PG11/R 161

EXS/PG36-PG13/R 161

EXS/PG36-PG16/R 161

EXS/PG36-PG21/R 161

EXS/PG36-PG29/R 161

EXS/PG36-PG48/E 161

EXS/PG36-PG9/R 161

EXS/PG42/DSP 165

EXS/PG42/HSP 165

EXS/PG42/SP 163

EXS/PG42/TSP 163

EXS/PG42-050/TC 160

EXS/PG42-075/TC 160

EXS/PG42-100/TC 160

EXS/PG42-125/TC 160

EXS/PG42-150/TC 160

EXS/PG42-200/TC 160

EXS/PG42-M16/TC 159

EXS/PG42-M20/TC 159

EXS/PG42-M25/TC 159

EXS/PG42-M32/TC 159

EXS/PG42-M40/TC 159

EXS/PG42-M50/TC 159

EXS/PG42-M63/TC 159

EXS/PG42-PG11/R 161

EXS/PG42-PG13/R 161

EXS/PG42-PG16/R 161

EXS/PG42-PG21/R 161

EXS/PG42-PG29/R 161

EXS/PG42-PG36/R 161

EXS/PG42-PG48/E 161

EXS/PG42-PG9/R 161

EXS/PG48/DSP 165

EXS/PG48/HSP 165

EXS/PG48/SP 163

EXS/PG48/TSP 163

EXS/PG48-050/TC 160

EXS/PG48-075/TC 160

EXS/PG48-100/TC 160

EXS/PG48-125/TC 160

EXS/PG48-150/TC 160

EXS/PG48-200/TC 160

EXS/PG48-M16/TC 159

EXS/PG48-M20/TC 159

EXS/PG48-M25/TC 159

EXS/PG48-M32/TC 159

EXS/PG48-M40/TC 159

EXS/PG48-M50/TC 159

EXS/PG48-M63/TC 159

EXS/PG48-PG11/R 161

EXS/PG48-PG13/R 161

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 175: Catalog Thomas Betts

Index

175

Thomas & Betts • www.tnb-hazardous.com

EXS/PG48-PG16/R 161

EXS/PG48-PG21/R 161

EXS/PG48-PG29/R 161

EXS/PG48-PG36/R 161

EXS/PG48-PG42/R 161

EXS/PG48-PG9/R 161

EXS/PG9/DSP 165

EXS/PG9/HSP 165

EXS/PG9/SP 163

EXS/PG9/TSP 163

EXS/PG9-050/TC 160

EXS/PG9-M16/TC 159

EXS/PG9-M20/TC 159

EXSB0310 143

EXSB0330 143

EXSB0410 143

EXSB0430 143

EXSB0510 143

EXSB0530 143

EXSB0610 143

EXSB0620 143

EXSB0630 143

EXSB0710 143

EXSB0720 143

EXSB0730 143

EXSB0810 143

EXSB0820 143

EXSB0910 143

EXSB0920 143

EXSH0310 143

EXSH0330 143

EXSH0410 143

EXSH0430 143

EXSH0510 143

EXSH0530 143

EXSH0610 143

EXSH0620 143

EXSH0710 143

EXSH0720 143

EXSH0810 143

EXSH0820 143

EXSH0910 143

EXSH0920 143

EXSHC0310 143

EXSHC0330 143

EXSHC0410 143

EXSHC0430 143

EXSHC0510 143

EXSHC0530 143

EXSHC0610 143

EXSHC0630 143

EXSHC0710 143

EXSHC0810 143

EXSHC0910 143

EXST0310 143

EXST0330 143

EXST0410 143

EXST0430 143

EXST0510 143

EXST0530 143

EXST0610 143

EXST0620 143

EXST0710 143

EXST0720 143

EXST0810 143

EXST0820 143

EXST0910 143

EXST0920 143

FB30-00000 83

FB70-00000 83

FF002 99

FF003 99

FF004 99

FF005 99

FF006 99

FF007 99

FF008 99

FF009 99

FF010 99

FF011 99

FF014 99

FF015 99

FF016 99

FF017 99

FF018 99

FF019 99

FF020 99

FF021 99

FF022 99

FF023 99

FF024 99

FF025 99

FF220-0G000 73

FF220EM-0G000 87

FF220VEM-0G000 87

FF236-0G000 73

FF240-0G000 73

FF240EM-0G000 87

FF240VEM-0G000 87

FF255-0G000 73

FF265-0G000 73

FL30P-00000 83

FR120-0G000 73

FR120EM-0G000 87

FR120VEM-0G000 87

FR136-0G000 73

FR140-0G000 73

FR140EM-0G000 87

FR140VEM-0G000 87

FR155-0G000 73

FR165-0G000 73

GUVC26-00000 125

GUVC36-00000 125

GUVL26-00000 125

GUVL36-00000 125

GUVT26-00000 125

GUVT36-00000 125

GUVX26-00000 125

GUVX36-00000 125

HAA0304 147

HAA0304E 145

HAA0304G1 145

HAA0304U 149

HAA0304U/SW 149

HAA0404 147

HAA0404E 145

HAA0404G1 145

HAA0404U 149

HAA0404U/SW 149

HAA0505 147

HAA0505E 145

HAA0505G1 145

HAA0505U 149

HAA0505U/SW 149

HAA0606 147

HAA0606E 145

HAA0606G1 145

HAA0606U 149

HAA0606U/SW 149

HAA0707 147

HAA0707E 145

HAA0707G1 145

HAA0707U 149

HAA0707U/SW 149

HAA0808 147

HAA0808E 145

HAA0808G1 145

HAA0808U 149

HAA0808U/SW 149

HAA0909 147

HAA0909E 145

HAA0909G1 145

HAA0909U 149

HAA0909U/SW 149

HAAM0304 147

HAAM0304E 145

HAAM0304G1 145

HAAM0304U 149

HAAM0304U/SW 149

HAAM0404 147

HAAM0404E 145

HAAM0404G1 145

HAAM0404U 149

HAAM0404U/SW 149

HAAM0505 147

HAAM0505E 145

HAAM0505G1 145

HAAM0505U 149

HAAM0505U/SW 149

HAAM0606 147

HAAM0606E 145

HAAM0606G1 145

HAAM0606U 149

HAAM0606U/SW 149

HAAM0707 147

HAAM0707E 145

HAAM0707G1 145

HAAM0707U 149

HAAM0707U/SW 149

HAAM0808 147

HAAM0808E 145

HAAM0808G1 145

HAAM0808U 149

HAAM0808U/SW 149

HAAM0909 147

HAAM0909E 145

HAAM0909G1 145

HAAM0909U 149

HAAM0909U/SW 149

HAAS0304G1 145

HAAS0304U 149

HAAS0304U/SW 149

HAAS0404 147

HAAS0404G1 145

HAAS0404U 149

HAAS0404U/SW 149

HAAS0505 147

HAAS0505G1 145

HAAS0505U 149

HAAS0505U/SW 149

HAAS0606 147

HAAS0606G1 145

HAAS0606U 149

HAAS0606U/SW 149

HAAS0707 147

HAAS0707G1 145

HAAS0707U 149

HAAS0707U/SW 149

HAAS0808 147

HAAS0808G1 145

HAAS0808U 149

HAAS0808U/SW 149

HAAS0909 147

HAAS0909G1 145

HAAS0909U 149

HAAS0909U/SW 149

HAM0304 147

HAM0304E 145

HAM0304G1 145

HAM0304U 149

HAM0304U/SW 149

HAM0404 147

HAM0404E 145

HAM0404G1 145

HAM0404U 149

HAM0404U/SW 149

HAM0505 147

HAM0505E 145

HAM0505G1 145

HAM0505U 149

HAM0505U/SW 149

HAM0606 147

HAM0606E 145

HAM0606G1 145

HAM0606U 149

HAM0606U/SW 149

HAM0707 147

HAM0707E 145

HAM0707G1 145

HAM0707U 149

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 176: Catalog Thomas Betts

176

Index

Thomas & Betts • www.tnb-hazardous.com

HAM0707U/SW 149

HAM0808 147

HAM0808E 145

HAM0808G1 145

HAM0808U 149

HAM0808U/SW 149

HAM0909 147

HAM0909E 145

HAM0909G1 145

HAM0909U 149

HAM0909U/SW 149

HAMM0304 147

HAMM0304E 145

HAMM0304G1 145

HAMM0304U 149

HAMM0304U/SW 149

HAMM0404 147

HAMM0404E 145

HAMM0404G1 145

HAMM0404U 149

HAMM0404U/SW 149

HAMM0505 147

HAMM0505E 145

HAMM0505G1 145

HAMM0505U 149

HAMM0505U/SW 149

HAMM0606 147

HAMM0606E 145

HAMM0606G1 145

HAMM0606U 149

HAMM0606U/SW 149

HAMM0707 147

HAMM0707E 145

HAMM0707G1 145

HAMM0707U 149

HAMM0707U/SW 149

HAMM0808 147

HAMM0808E 145

HAMM0808G1 145

HAMM0808U 149

HAMM0808U/SW 149

HAMM0909 147

HAMM0909E 145

HAMM0909G1 145

HAMM0909U 149

HAMM0909U/SW 149

HAMS0304G1 145

HAMS0304U 149

HAMS0304U/SW 149

HAMS0404 147

HAMS0404G1 145

HAMS0404U 149

HAMS0404U/SW 149

HAMS0505 147

HAMS0505G1 145

HAMS0505U 149

HAMS0505U/SW 149

HAMS0606 147

HAMS0606G1 145

HAMS0606U 149

HAMS0606U/SW 149

HAMS0707 147

HAMS0707G1 145

HAMS0707U 149

HAMS0707U/SW 149

HAMS0808 147

HAMS0808G1 145

HAMS0808U 149

HAMS0808U/SW 149

HAMS0909 147

HAMS0909G1 145

HAMS0909U 149

HAMS0909U/SW 149

HF55P-00000 85

HF70P-00000 85

M005.1 97

M005.2 97

M005.3 97

M005.4 97

M005.5 97

P001 97

P002 97

P004 97

P006 97

P007 97

P008 97

P009 97

P010 97

P012 97

P015 97

P017 97

P018 97

P019 97

P021 97

P022 97

P023 97

P025 97

P026 97

P030 97

PA1-10 1/2” 151

PA1-13 1/2” 151

PA1-8 1/2” 151

PA1B 1/2” 155

PA1B M20 155

PA2-10 3/4” 151

PA2-13 3/4” 151

PA2-15 3/4” 151

PA2-18 3/4” 151

PA2B 3/4” 155

PA2B M25 155

PA3-18 1” 151

PA3-21 1” 151

PA3-24 1” 151

PA3B 1” 155

PA3B M32 155

PA4-24 1,1/4” 151

PA4-27 1,1/4” 151

PA4-30 1,1/4” 151

PA4B 1,1/4” 155

PA4B M40 155

PA5-33 1,1/2” 151

PA5-36 1,1/2” 151

PA5B 1, 1/ 155

PA5B M50 155

PA6-39 2” 151

PA6-42 2” 151

PA6-45 2” 151

PA6B 2” 155

PA6B M63 155

PA7-48 2,1/2” 151

PA7-51 2,1/2” 151

PA7B 2,1/2” 155

PA7B 2,1/2” 155

PA7B M75 155

PAP1-10 1/2” 151

PAP1-13 1/2” 151

PAP1-8 1/2” 151

PAP1B 1/2” 155

PAP1B M20 155

PAP2-10 3/4” 151

PAP2-13 3/4” 151

PAP2-15 3/4” 151

PAP2-18 3/4” 151

PAP2B 3/4” 155

PAP2B M25 155

PAP3-18 1” 151

PAP3-21 1” 151

PAP3-24 1” 151

PAP3B 1” 155

PAP3B M32 155

PAP4-24 1,1/4” 151

PAP4-27 1,1/4” 151

PAP4-30 1,1/4” 151

PAP4B 1,1/4” 155

PAP4B M40 155

PAP5-33 1,1/2” 151

PAP5-36 1,1/2” 151

PAP5B 1, 1/ 155

PAP5B M50 155

PAP6-39 2” 151

PAP6-42 2” 151

PAP6-45 2” 151

PAP6B 2” 155

PAP6B M63 155

PAP7-48 2,1/2” 151

PAP7-51 2,1/2” 151

PAP7B 2,1/2” 155

PAP7B M75 155

PEM20T4 153

PEM20T5 153

PEM20T6 153

PEM25T6 153

PEM25T7 153

PEM32T7 153

PEM32T8 153

PEM40T9 153

PEM50T10 153

PEM63T11 153

PEM75T12 153

PEPM20T5 153

PEPM20T6 153

PEPM20T7 153

PEPM25T7 153

PEPM25T8 153

PEPM32T8 153

PEPM32T9 153

PEPM40T10 153

PEPM50T11 153

PEPM63T12 153

PEPM75T13 153

PR01 130

PR02 130

PR03 130

PR04 130

PR05 130

PR06 130

PR07 130

PR07V 130

PRC10 130

PRC20 130

PRC30 130

PRC40 130

PRC50 130

PRC60 130

PRC70 130

QF250G-00000 77

QF250P-00000 77

QF400G-00000 77

QF400P-00000 77

REA20 130

SF150G-00000 77

SF150P-00000 77

SF250G-00000 77

SF250P-00000 77

SF400G-00000 77

SF400P-00000 77

SF70G-00000 77

SF70P-00000 77

SRC215 127

SRC215V 127

SRC330 127

SRC340 127

SRC415 127

V001 95

V002 95

V004 95

V005 95

V006 95

V006N 95

V007N 95

V008 95

V008N 95

V009 95

V012 95

V012A 95

V014 94

V015 94

V016 94

V018 94

V021 94

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 177: Catalog Thomas Betts

Index

177

Thomas & Betts • www.tnb-hazardous.com

V023 94

V024 94

VAB10 130

VAC10 130

VAJ10 130

VAR10 130

VAV10 130

WHMB03 167

WHMB04 167

WHMB05 167

WHMB06 167

WHMB07 167

WHMB08 167

XB100-10BV 109

XB100-6BR 109

XB100-6BV 109

XB100A-10BV 109

XB100A-6BR 109

XB100A-6BV 109

XB10A-SI 111

XB10A-SI 111

XB10-SI 111

XB10-SI 111

XB150 121

XB215VA 119

XB21A 119

XB21FA 119

XB21VA 119

XB22A 119

XB22AMP 119

XB23A 119

XB26A 119

XB300 117

XB38A 119

XB38AMP 119

XB400 117

XB41A 119

XB43A 119

XB510 117

XB520 117

XB570 117

XB700 117

XB710 117

XB750 117

XB950 117

XB960 117

XBAMP 119

XBI100 121

XBI200 121

XBI215VA 123

XBI21A 123

XBI21FA 123

XBI21VA 123

XBI22A 123

XBI22AMP 123

XBI23A 123

XBI26A 123

XBI300 121

XBI38A 123

XBI38AMP 123

XBI400 121

XBI41A 123

XBI43A 123

XBI500 121

XBI600 121

XBIAMP 123

XBL15 113

XBL20 113

XBL215VA 115

XBL21A 115

XBL21FA 115

XBL21VA 115

XBL22A 115

XBL22AMP 115

XBL23A 115

XBL25 113

XBL26-25R 111

XBL26A 115

XBL28-25BR 111

XBL35 113

XBL38A 115

XBL38AMP 115

XBL40 113

XBL41A 115

XBL43A 115

XBL45 113

XBL55 113

XBL65 113

XBL75 113

XBLAMP 115

XDF140-00000 41

XDF165-00000 41

XEF110G-00000 37

XEF110P-00000 37

XEF140G-00000 37

XEF140P-00000 37

XEL120-0G000 33

XEL120V-0G000 33

XEL220-0G000 33

XEL220V-0G000 33

XEL3001-00000 55

XEL30011-0G000 33

XEL30011V-0G000 33

XEL3001V-00000 55

XEL3002-00000 55

XEL30028-0G000 33

XEL30028V-0G000 33

XEL3002V-00000 55

XEL3008-0G000 33

XEL3008V-0G000 33

XEL3009-0G000 33

XEL3009V-0G000 33

XEL300A-00000 55

XEL300AI-00000 55

XEL300AIV-00000 55

XEL300AK-00000 55

XEL300AKV-00000 55

XEL300AV-00000 55

XEL300SI-00000 55

XEL300SIV-00000 55

XEL80A-00000 55

XEL80AI-00000 55

XEL80AIV-00000 55

XEL80AK-00000 55

XEL80AKV-00000 55

XEL80AV-0J000 55

XEL80SI-0J000 55

XEL80SIV-0J000 55

XEP120-0G000 35

XEP120V-0G000 35

XEP220-0G000 35

XEP220V-0G000 35

XEP30011-0G000 35

XEP30011V-0G000 35

XEP30028-0G000 35

XEP30028V-0G000 35

XEP3008-0G000 35

XEP3008V-0G000 35

XEP3009-0G000 35

XEP3009V-0G000 35

XF001 99

XFB30-00000 39

XFB70-00000 39

XFF012 99

XFF013 99

XFF220-0G000 29

XFF220EM-0G000 51

XFF220V-0G000 29

XFF220VEM-0G000 51

XFF236-0G000 29

XFF236V-0G000 29

XFF240-0G000 29

XFF240EM-0G000 51

XFF240V-0G000 29

XFF240VEM-0G000 51

XFF255-0G000 29

XFF255V-0G000 29

XFF265-0G000 29

XFF265V-0G000 29

XFL30P-00000 39

XFP120-0G000 31

XFP120EM-0G000 53

XFP120V EM-0G000 53

XFP120V-0G000 31

XFP136-0G000 31

XFP136V-0G000 31

XFP140-0GG000 31

XFP140EM-0G000 53

XFP140V EM-0G000 53

XFP140V-0G000 31

XFP155-0G000 31

XFP155V-0G000 31

XFP165-0G000 31

XFP165V-0G000 31

XFP220-0G000 31

XFP220EM-0G000 53

XFP220V EM-0G000 53

XFP220V-0G000 31

XFP236-0G000 31

XFP236V-0G000 31

XFP240-0G000 31

XFP240EM-0G000 53

XFP240V EM-0G000 53

XFP240V-0G000 31

XFP255-0G0000 31

XFP255V-0G000 31

XFP265-0G000 31

XFP265V-0G000 31

XFR120-0G000 29

XFR120EM-0G000 51

XFR120V-0G000 29

XFR120VEM-0G000 51

XFR136-0G000 29

XFR136V-0G000 29

XFR140-0G000 29

XFR140EM-0G000 51

XFR140V-0G000 29

XFR140VEM-0G000 51

XFR155-0G000 29

XFR155V-0G000 29

XFR165-0G000 29

XFR165V-0G000 29

XMC36 127

XPLFL110 157

XPLFL112 157

XPLFL115 157

XPLFL118 157

XPLFL124 157

XPLFL16 157

XPLFL18 157

XPLFL212 157

XPLFL215 157

XPLFL218 157

XPLFL224 157

XPLFL236 157

XPLFL318 157

XQF250G-00000 37

XQF250P-00000 37

XQF400G-00000 37

XQF400P-00000 37

XSF150G-00000 37

XSF150P-00000 37

XSF250G-00000 37

XSF250P-00000 37

XSF400G-00000 37

XSF400P-00000 37

XSF70G-00000 37

XSF70P-00000 37

Z001 95

Part No. Page Part No. Page Part No. Page Part No. Page Part No. Page

Page 178: Catalog Thomas Betts

USA & Canada

178

Thomas & Betts WorldwideIndustrial Capabilities

Thomas & Betts CorporationWorld Headquarters

8155 T&B BoulevardMemphis, TN 38125T 901.252.8000I www.tnb-europe.com

Kopex InternationalUK Head Offi ce

Station Road, Coleshill, Birmingham, B46 1HTT +44 (0) 1675 468 213F +44 (0) 1675 468 280I www.kopex-ex.com

Thomas & BettsEMEA European Centre

200 Chaussee de Waterloo B-1640 Rhode-St-GeneseBelgiumT +32 (0) 2 359 82 00F +44 (0) 2 359 82 01E [email protected]

Thomas & BettsAsia (Singapore) Pte Ltd

10 Ang Mo kio Street 65, #06-07 TechpointSingapore 569059T +65 6720 8828F +65 6720 8780E [email protected]

DTSInternational Call Centre

Z.I. Parc d’Activités de la Gare19 à 21 avenue Henri BeaudeletB.P. 27 - 77831 Ozoir Cedex FranceT +33 (0) 1 64 40 27 26F +33 (0) 1 64 40 20 11E [email protected] www.dtselec.fr

T&B Headquarters

Thomas & Betts • www.tnb-hazardous.com

Page 179: Catalog Thomas Betts

Europe, Middle East, Asia

Thomas & Betts - Industrial Capabilities

Thomas & Betts • www.tnb-hazardous.com

179

Page 180: Catalog Thomas Betts

Battery LED Signals SATI

IP 54 IP 56 IP 64 IP 66 IP 67

Healthy(test OK)

Emergency orIndicator

Lamp Fault(must bereplaced)

Test inProgress

(waiting end of test)

Fault(replacebattery)

Healthy Emergency orIndicator

Lamp Fault

Test inProgress

Fault

Thomas & Betts • www.tnb-hazardous.com

Key of Symbols

DTS & Kopex Ex Symbols

Key of Symbols

Market Segments

Product Characteristics

Group I Group II Class I Class II Division 1 Division 2 IK 09 IK 10

Utilities /Power

Food &Beverage

Marine &Shipbuilding

Onshore &Offshore

Chemical &Pharmaceutical

Mining

Ex e Ex d Ex n Ex de Ex tb Ex tDEx t Ex tc

Zone 0 Zone 1 Zone 2 Zone 20 Zone 21 Zone 22

Gas IIB Gas IIC Dust IIIC Dust A21

67665654 64

Ex nA Ex ia Ex eia

180

Page 181: Catalog Thomas Betts
Page 182: Catalog Thomas Betts

The content of the Thomas & Betts catalogue has been carefully checked for accuracy at the time of print. However, Thomas & Betts doesn’t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may result from any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain.

Copyright Thomas & Betts 2011. Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No part of this publication may be reproduced, copied or transmitted in any form or by any means, without our prior written permission. Images, trade marks, brands, designs and technology are also protected by other intellectual prop-erty rights and may not be reproduced or appropriated in any manner without written permission of their respective owners. Thomas & Betts reserves the right to change and improve any product specifi cations or other mentions in the catalogue at its own discretion and at any time. These conditions of use are governed by the laws of the Netherlands and the courts of Amsterdam shall have exclusive jurisdiction in any dispute.

Thomas and Betts manufacture and design a wide range of electrical equipment for hazardousand hostile environments to ensure the safety of the personnel working in them. The extensive range covers Kopex-Ex metallic and non metallic conduit and fi ttings and the DTS range of lighting junction and control boxes. These products are approved to a wide range of hazardous area standards including ATEX, IECEx, UL, CSA, GOST and Inmetro.

DTSThomas & Betts Sales Offi ce

19/21 Avenue Henri BeaudeletBP2777330 Ozoir la FerrièreFranceT +33 (0) 1 64 40 27 26E [email protected]

Kopex InternationalThomas & Betts Sales Offi ce

Station Road, Coleshill Birmingham, B46 1HTT +44 (0) 1675 468 213E [email protected]

Thomas & BettsEuropean Head Offi ce

Benelux BVBAWaterloose Steenweg 200B-1640 Sint-Genesius-RodeBelgiumT +32 (0) 56 78 35 35E [email protected]

LIT-

140G

BR 0

6/12

• D

esig

ned

by w

ww

.uc4

.co.

uk