CAT-1137-03 CIA Scanning Abutment Range€¦ · CIA Scanning Abutment Range Note: Not to be used...

1
www.southernimplants.com Page 1 of 1 CAT-1137-03 (C962) CIA Scanning Abutment Range Note: Not to be used with Cerec 1 and Cerec 2 External Hex Range Tri-NEX Range Internal Octagon (IT) Range The above CIA abutments, for Externally Hexed Implants, all use 3 Series prosthetic screws. Uses TS-L-18 / GS-L-18 / TS-L-18C prosthetic screws Uses TS-L-20 / GS-L-20 / TS-L-20C prosthetic screws Uses TSIT2 / GSIT2 prosthetic screws CIA-EX-34 CIA-NX-34 Ø3.25mm interface Ø4.0mm interface Ø5.0mm interface Ø6.0mm interface Engaging Non-Engaging Engaging Non-Engaging Engaging Non-Engaging Engaging Non-Engaging CIA-EX-60 CIA-NX-60 CIA-EX-50 CIA-NX-50 CIA-EX-40 CIA-NX-40 CIA-ITS CIA-ITS-NE CIA-ITS6 CIA-ITS6-NE Ø4.8mm interface Ø6.5mm interface Engaging Non-Engaging Engaging Non-Engaging CIA-EL-35 CIA-NL-35 CIA-EL-43 CIA-NL-43 CIA-EL-50 CIA-NL-50 CIA-EL-60 CIA-NL-60 Ø4.3mm interface Ø6.0mm interface Ø5.0mm interface Ø3.5mm interface Engaging Non-Engaging Engaging Non-Engaging Engaging Non-Engaging Engaging Non-Engaging Internal Hex Range (M-Series / PROVATA) Uses TS-Z-18 / GS-Q-18 prosthetic screws CIA-EM CIA-NM CIA-EZ CIA-NZ Standard interface Wide interface Engaging Non-Engaging Engaging Non-Engaging Images are for illustration purposes only and do not necessarily accurately represent the product. Not all products are cleared for sale in all countries.

Transcript of CAT-1137-03 CIA Scanning Abutment Range€¦ · CIA Scanning Abutment Range Note: Not to be used...

Page 1: CAT-1137-03 CIA Scanning Abutment Range€¦ · CIA Scanning Abutment Range Note: Not to be used with Cerec 1 and Cerec 2 External Hex Range Tri-NEX Range Internal Octagon (IT) Range

www.southernimplants.com

Page 1 of 1CAT-1137-03 (C962)

CIA Scanning Abutment Range

Note: Not to be used with Cerec 1 and Cerec 2

External Hex Range

Tri-NEX Range

Internal Octagon (IT) Range

The above CIA abutments, for Externally Hexed Implants, all use 3 Series prosthetic screws.

Uses TS-L-18 / GS-L-18 / TS-L-18C prosthetic screws

Uses TS-L-20 / GS-L-20 / TS-L-20C prosthetic screws

Uses TSIT2 / GSIT2 prosthetic screws

CIA-EX-34 CIA-NX-34

Ø3.25mm interface Ø4.0mm interface Ø5.0mm interface Ø6.0mm interface

Engaging Non-Engaging Engaging Non-Engaging Engaging Non-EngagingEngaging Non-Engaging

CIA-EX-60 CIA-NX-60CIA-EX-50 CIA-NX-50CIA-EX-40 CIA-NX-40

CIA-ITS CIA-ITS-NE CIA-ITS6 CIA-ITS6-NE

Ø4.8mm interface Ø6.5mm interface

Engaging Non-Engaging Engaging Non-Engaging

CIA-EL-35 CIA-NL-35 CIA-EL-43 CIA-NL-43 CIA-EL-50 CIA-NL-50 CIA-EL-60 CIA-NL-60

Ø4.3mm interface Ø6.0mm interfaceØ5.0mm interface Ø3.5mm interface

Engaging Non-Engaging Engaging Non-EngagingEngaging Non-EngagingEngaging Non-Engaging

Internal Hex Range (M-Series / PROVATA)

Uses TS-Z-18 / GS-Q-18 prosthetic screws

CIA-EM CIA-NM CIA-EZ CIA-NZ

Standard interface Wide interface

Engaging Non-Engaging Engaging Non-Engaging

Images are for illustration purposes only and do not necessarily accurately represent the product. Not all products are cleared for sale in all countries.