CAMPUS FACILITIES Planning, Design, & Construction...
Transcript of CAMPUS FACILITIES Planning, Design, & Construction...
TA
RA
OF
FIC
E
MAINTENANCE
SHOP
700
800
900
1
0
0
0
1
1
0
0
600
500
400
300
100
1300
1200
1400
1500
200
1
6
0
0
TARA APARTMENTS
E
S
T
A
D
IU
M
B
L
V
D
M
O
7
4
0
A
S
H
L
A
N
D
R
O
A
D
E
A
S
T
C
A
M
P
U
S
D
R
IV
E
ROLLINS BOTTOMS
AR
TS
&
S
CIE
NC
E
ANIMAL
SCIENCES
RESEARCH
CENTER
401 E.
STEWART
417 SOUTH
FIFTH
HITT ST GARAGE
FRANCIS
QUADRANGLE
FIR
E
ST
AT
ST
UD
EN
T R
EC
RE
AT
IO
N
CE
NT
ER
ST BLDG
MA
NO
R
HO
US
E
LOCUST
OUTDOOR TRACK
FACILITY
STUDENT
HEALTH
MEDICAL SCIENCE
FIELD
SIMMONS
R
O
C
K
Q
U
A
R
R
Y
W
A
R
E
H
O
U
S
E
A. L. G
USTIN
CLUB HOUSE
FIELD
STANKOWSKI
LOWRY
MALL
LEE
HILLS
SC
HL
UN
DT
AN
NE
X
LIBRARY
HALL
CENTER
SUPPORT
MUSEUM
CENTER
QUARRY
ROCK
MUSIC
JESSE HALL
McKEE
BREWER
VETERINARY
MULTIPURPOSE
SERVICES
GREEN-
BOTANY
BUILDING
GARAGE
UNIVERSITY
GENERAL
CENTER
ANIMAL
LAB
CENTER
RESEARCH
DALTON
HEARNES
REACTOR
RESEARCH
BROOKFIELD
DUTTON
TAYLOR
TOM
FIELD
FAUROT
HALL
UNIVERSITY
WIL
LIA
MS
WA
LT
ER
NEFF
LAB
DIAGNOSTIC
TROWBRIDGE
READ
HEINKEL
PSYCHOLOGY
LO
WR
Y
TWAIN
MARK
HU
LS
TO
N
SWITZLER
CONNAWAY
ECKLES
CLYDESDALE
CENTER
TELECOM.
LA
W
S
L
A
T
H
R
O
P
P
A
V
ILIO
N
D
O
B
B
S
HATCH
ENGINEERING
AGRICULTURAL
SCIENCE
VETERINARY
MEDICINE
CROWDER
LIBRARY
LOTTES
NURSING
PERSHING
GY
M
RO
TH
WE
LL
FIELD HOUSE
BINGHAM
SCHURZ
TUCKER
GYM
AGRICULTURE
GILLETT
HUDSON
ROLLINS
WOLPERS
JOHNSTON
H
E
I
G
H
T
S
U
N
I
V
E
R
S
I
T
Y
L
E
W
I
SC
L
A
R
K
SC
HW
EIT
ZE
R
WH
IT
TE
N
PIC
KA
RD
SW
ALLO
W
TATE
GENTRY
SCHLUNDT
CURTIS
STANLEYGWYNN
SCIENCES
GEOLOGICAL
FINE ARTS
AND
CHEMISTRY
PHYSICS
LEFEVRE
STEWART
WATERS
MIDDLEBUSH
MUMFORD
UNION
STUDENT
DRAMA
ELLIS
LAFFERRE
TOWNSEND
HILL
HEALTH
STUDENT
NOYES
PA
RK
ER
WEST
ENGINEERING
SUPPORT CENTER
ACADEMIC
HALL
LONDON
GA
NN
ET
T
ADDITION
NEFF
McDAVID
LOEB
McREYNOLDS
AVENUE
CONLEY
GARAGE
R
R
C
HOUSE
FIELD
HINKSON
UNIVERSITY
AVENUE
GARAGE
MEMORIAL
TURNER AVENUE
GARAGE
MARYLAND AVENUE
GARAGE
STADIUM
MEMORIAL
U
N
I
T
F
SH
OP
IN
ST
RU
ME
NT
SC
IE
NC
E
S
T
O
R
A
G
E
P
A
R
K
D
E
V
.
R
E
S
E
A
R
C
H
C
A
P
S
U
L
E
P
I
P
E
L
I
N
E
R
E
S
E
A
R
C
H
L
A
B
7
0
2
7
0
3
709
0
0
4
0
0
3
0
0
2
0
0
1
PRESIDENT'S RESIDENCE
CF
GREEN-
C
F
S
T
O
R
A
G
E
OLD
HOUSE
RONALD McDONALD
PO
ULT
RY
N
U
TR
IT
IO
N
P
O
U
L
T
R
Y
E
N
V
I
R
O
N
M
E
N
T
A
L
SA
NB
OR
N F
IELD
BU
ILD
ING
R
R
C
R
R
C
C
H
E
M
I
C
A
L
IN
C
IN
E
R
A
T
O
R
S
O
LID
S
AB
AT
TO
IR
022
USDA
GARAGE
HOSPITAL
STUDENT
BAPTIST
CENTER
FIELDHOUSE
STANKOWSKI
CONLEY HOUSE
STUDENT
SUCCESS
RE
SID
EN
CE
ON
Q
UA
D
COLUMBIA
PROFESSIONAL
McALESTER
FINE
ARTS
ANNEX
NO
RT
H
WE
LL
STEPHENS
CHAPEL
ADDITION
SOUTH
QUAD
KUHLMAN
COURT
SANBORN
FIELD
NO
RT
HE
AS
T
WE
LL
DINING
CF
SHED #1
HOUSE
WEST
SOUTH-
WELL
GH
1
GH
2
GH
020
GH
019
GH
018
GH
021GH
023
GH
022W
GH
022E
GH
0
25
HAY BARN
RAPTOR REHABILITATION
ST
OR
AG
E B
LD
G
RA
PT
OR
RE
SE
AR
CH
MULE BARN
CULTURE
BLACK
RESOURCE
CENTER
DEVINE
DANIEL
PAVILION
ANHEUSER BUSCH
NA
TU
RA
L R
ES
OU
RC
ES
CRITICAL
CARE
R
R
C
L
O
W
L
E
V
E
L
R
A
D
I
O
A
C
T
I
V
E
W
A
S
T
E
S
T
O
R
A
G
E
N. T
ELE
CO
M
SW
IT
CH
BALD EAGLE AVIARY
PASTURE SHELTER #1
H
I
N
K
S
O
N
F
I
E
L
D
R
E
S
T
R
O
O
M
SHELTER
R
E
S
T
R
O
O
M
EPPLE
FIELD
S
H
E
L
T
E
R
TO
B 1
TO
B 2
TOB 3
BUS
SHELTER
RESEARCH
PARK
DEVELOPMENT
GARAGE
C
O
O
L
I
N
G
T
O
W
E
R
COOLING
TOWER
EAST
ST BLDG
LOCUST
WEST
TOWER
ADDITION
CHEMISTRY
COOLING
TOWER
AG
RIC
ULT
UR
E
B
UILD
IN
G
WILLIAM C.
MCHANEY
HALL
LAB
TELECOM
GENERATOR
BUILDING
R
O
C
K
Q
U
A
R
R
Y
C
E
N
T
E
R
A
N
N
E
X
1
,
2
&
3
M
A
R
X
B
L
D
G
R
R
C
R
R
C
A
Q
U
E
O
U
S
F
L
A
M
M
A
B
L
E
R
R
C
T
R
A
I
L
E
R
CF
STORAGE
SHED #2
CF
SALT
SCIENCE
MATH
WELL
STANLEY
ADDITION
JESSE HALL
AUDITORIUM
POWER
PLANT
ENERGY
MANAGEMENT
COAL HANDLING
HATCH
LOBBY
SC
HU
RZ
LO
BB
Y
MA
SO
N E
YE
IN
ST
IT
UT
E
DIA
BE
TE
S
HOSPITAL
CONCOURSE
GLEN L. McELROY M.D.
RAPTOR
CAGES
P
H
Y
S
I
C
S
P
R
E
S
S
B
O
X
TE
AM
ST
OR
E
T
I
C
K
E
T
B
O
X
A
T
H
L
E
T
I
C
M
A
I
N
T
RALPH O. &
DEBBIE TAYLOR
STADIUM
M
A
I
N
T
E
N
A
N
C
E
G
U
S
T
I
N
R
E
S
E
A
R
C
H
P
A
R
K
S
U
B
S
T
A
T
IO
N
M
P
EAST
WEST
SEARS
GREENHOUSE
AR
TS
&
S
CIE
NC
E M
ALL
SHELDEN ACADEMIC
RESOURCE CENTER
BAND
STORAGE
SHED
1999
ADDITION
TICKET BOOTH
SHELTER HOUSE
CORNELL
HALL
TO
B 5
TO
B 4
POWER
PLANT
ADDT'N
2001
CENTER
LIFE SCIENCES
CENTER
SE
RV
IC
E
BU
IL
DIN
G
AVENUE
VIRGINIA
PARKING
GARAGE
RE
YN
OLD
S A
LU
MN
I
CE
NT
ER
ST
RIC
KLA
ND
BEEF BARN
STRINGER WING
M
P
SWINE
RESEARCH
CENTER
S
W
I
N
E
S
A
N
I
T
A
T
I
O
N
B
L
D
G
CENTER
N
O
R
T
H
C
E
N
T
E
R
S
O
U
T
H
HOSPITAL & CLINICS
SCHWEITZER
ADDITION
STORAGE
ADDITION
MIZZOU
ATHLETIC
TRAINING
FACILITY
G
U
S
T
I
N
CHILLER
NORTH
OFFICE
ADDITION
NANO
BLDG
MIZZOU
ARENA
GREEN
TENNIS
TA
RA
OF
FIC
E
MAINTENANCE
SHOP
700
800
900
1
0
0
0
1
1
0
0
600
500
400
300
100
13
00
12
00
14
00
1500
20
0
1
6
0
0
C
A
R
P
O
R
T
TARA APARTMENTS
C
O
LLE
G
E
A
V
E
H
A
LL
PLAZA 900
R
E
S
P
E
C
T
R
E
S
P
O
N
S
I
B
I
L
I
T
Y
EXCELLENCE
DISCOVERY
CLINICAL SUPPORT
& EDUCATION BLDG
MED SCIENCE
ADDITION
SU
PP
OR
T
AN
NE
X
COOLING
TOWER
BIO-WASTE
OLD
PEACE
PARK
S
P
R
O
V
ID
E
N
C
E
R
O
A
D
M
O
1
6
3
S
P
R
O
V
ID
E
N
C
E
R
O
A
D
M
O
1
6
3
W STADIUM BLVD MO 740
HOSPITAL DRIVE
S
T
A
D
I
U
M
B
L
V
D
M
O
7
4
0
S
T
A
D
I
U
M
B
L
V
D
M
O
7
4
0
D
E
A
V
E
R
M
E
M
O
R
I
A
L
D
R
I
V
E
MA
RY
LA
ND
A
VE
NU
E
C
O
N
L
E
Y
A
V
E
N
U
E
T
U
R
N
E
R
A
V
E
N
U
E
B
U
R
N
A
M
R
O
A
D
K
E
N
T
U
C
K
Y
B
LV
D
S
R
O
LLIN
S
S
T
R
E
E
T
E STEWART ROAD
S
P
R
O
V
ID
E
N
C
E
R
O
A
D
M
O
1
6
3
S P
RO
VID
EN
CE
R
OA
D
MO
163
S 4th S
TR
EE
T
S
5
t
h
S
T
R
E
E
T
S 5th S
TR
EE
T
MA
RY
LA
ND
A
VE
NU
E
MIS
SO
UR
I A
VE
NU
E
C
U
R
T
IS
R
O
A
D
R
IC
H
M
O
N
D
A
V
E
N
U
E
M
A
R
Y
LA
N
D
A
V
E
N
U
E
SA
N
FO
R
D
S
TR
EE
T
DE
AN
S D
RIV
E
S 5th S
TR
EE
T
S 6th S
TR
EE
T
S P
RO
VID
EN
CE
R
OA
D
MO
163
CHERRY STREET
LOCUST STREET
ELM STREETELM S
TREET
S 6th S
TR
EE
T
CHERRY STREET
LOCUST STREET
S 9th S
TR
EE
T
ELM STREET
S 10th S
TR
EE
T
WA
TS
ON
P
LA
CE
HIT
T S
TR
EE
T
HAMILTON WAY
PAQUIN STREET
UNIVERSITY AVENUE
S 8th S
TR
EE
T
U
N
IV
E
R
S
IT
Y
H
E
IG
H
T
S
U
N
I
V
E
R
S
I
T
Y
V
I
L
L
A
G
E
UNIVERSITY AVENUE
S ROLLINS STREET
BASS AVENUE
ANTHONY STREET
ROSEMARY LANE
WILSON AVENUE
LE
E S
TR
EE
T
ROSS STREET
BOUCHELLE AVENUE
S W
ILLIA
M S
TR
EE
T
MO
763
CO
LLE
GE
A
VE
NU
E
MO
763
CO
LLE
GE
A
VE
NU
E
BLA
IR
C
OU
RT
E STADIUM BLVD
MO 740
C
O
L
L
E
G
E
A
V
E
N
U
E
M
O
7
6
3MO
NK
D
RIV
E
VIR
GIN
IA
A
VE
NU
E
S
O
U
T
H
P
A
R
K
D
R
I
V
E
E
S
T
A
D
IU
M
B
L
V
D
M
O
7
4
0
A
S
H
L
A
N
D
R
O
A
D
R
O
C
K
Q
U
A
R
R
Y
R
O
A
D
WA
UG
H S
TR
EE
T
MA
TT
HE
WS
S
TR
EE
T
HIT
T S
TR
EE
T
HIT
T S
TR
EE
T
WILLIA
MS
S
TR
EE
T
EA
ST
C
AM
PU
S D
RIV
E
E
A
S
T
C
A
M
P
U
S
D
R
IV
E
E
A
S
T
C
A
M
P
U
S
L
O
O
P
F
E
L
L
O
W
S
P
L
A
C
E
C
A
P
E
N
P
A
R
K
D
R
I
V
E
CH
AM
PIO
NS
D
RIV
E
CHAMPIONS DRIVE
C
H
A
M
P
I
O
N
S
D
R
I
V
E
M
IC
K
D
E
A
V
E
R
M
E
M
O
R
IA
L
D
R
D
R
M
A
R
C
U
S
S
Z
U
B
E
R
D
R
R
E
S
E
A
R
C
H
P
A
R
K
D
R
I
V
E
M
IC
K
C
A
R
R
IE
F
R
A
N
K
E
D
R
IV
E
RESEARCH PARK DRIVE
CA
RR
IE
F
RA
NK
E D
RIV
E
S 7th S
TR
EE
T
S ROLLINS STREET
E
A
S
T
C
A
M
P
U
S
L
O
O
P
E
A
S
T
C
A
M
P
U
S
D
R
I
V
E
A
S
H
L
A
N
D
R
O
A
D
LAKE ST
S 9th S
TR
EE
T
E
S
T
E
W
A
R
T
R
O
A
D
RE
YN
OLD
S
JO
UR
NA
LIS
M
IN
ST
IT
UT
E
PARKING STRUCTURE #7
LIFE
SCIENCE
INCUBATOR
ORTHOPAEDIC
INSTITUTE
MIS
SO
UR
I
PS
YC
HIA
TR
IC
CE
NT
ER
HAWTHORN
DOGWOOD
GA
LE
NA
DEFOE-GRAHAM
G
Y
M
N
A
S
T
I
C
S
A
N
D
D
A
N
C
E
P
R
A
C
T
I
C
E
F
A
C
I
L
I
T
Y
MU STUDENT CENTER
GATEWAY
PATIENT
CARE
TOWER
PATIENT
CENTERED
CARE
LEARNING
CENTER
BROOKS HALL
SOFTBALL STADIUM
1110 S
COLLEGE
AVE
C
A
T
T
L
E
D
R
I
V
E
PROJECT NOTES:
1. REFER TO CIVIL, STRUCTURAL, ARCHITECTURAL, FIRE
PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL,
DRAWINGS AS APPLICABLE, TO DETERMINE EXACT EXTENT OF
DEMOLITION REQUIRED BY THOSE DISCIPLINES TO COORDINATE
WITH NEW CONSTRUCTION.
2. ANY OPERATION WHERE HIGH LEVELS OF NOISE ARE EXPECTED ON
THE CONSTRUCTION SITE WILL NEED TO BE COORDINATED AND
APPROVED WITH THE OWNER'S REPRESENTATIVE AT LEAST 48
HOURS PRIOR TO THE WORK BEING INITIATED.
3. AREAS NOT UNDER CONSTRUCTION NEED TO BE MAINTAINED FOR
PUBLIC ACCESS AND CIRCULATION. PROPER SAFETY
PRECAUTIONS TO BE OBSERVED.
4. MAINTAIN AND PROTECT THE EXISTING CONDITIONS IN THE AREA
DURING THE CONSTRUCTION PERIOD UNLESS OTHERWISE NOTED.
5. EVERY DIMENSION THAT IS DIRECTLY OR INDIRECTLY RELATED TO
EXISTING STRUCTURE OR CONSTRUCTION IS TO BE CAREFULLY
MEASURED AND COORDINATED WITH ADJACENT CONDITIONS. ALL
BIDDING AND CONSTRUCTION COSTS ARE TO INCLUDE A CAREFUL
ANALYSIS OF EACH RELATING TRADE. REPORT DISCREPANCIES
WHICH MAY ADVERSELY AFFECT FINISH WORK AND BUILT-IN WORK
TO THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING OF
CONSTRUCTION.
6. CONTRACTOR SHALL COMPLY WITH ALL DIRECTIVES OF THE
OWNER'S REPRESENTATIVE. IF CONFLICTS BETWEEN DRAWINGS,
SPECIFICATIONS AND REQUIREMENTS OF BUILDING OWNER
AND/OR OPERATORS ARISE, THEY SHALL BE BROUGHT TO THE
ATTENTION OF THE OWNER'S REPRESENTATIVE IMMEDIATELY.
7. THE CONTRACTOR SHALL CONTAIN ALL CONSTRUCTION ACTIVITY,
INCLUDING STORAGE OF MATERIAL AND EQUIPMENT, WITHIN THE
CONSTRUCTION LIMITS, AT ALL TIMES BEING RESPONSIBLE FOR
AND ABIDING BY RULES AND REGULATIONS OF THE OWNER.
8. WHERE EXISTING MECHANICAL EQUIPMENT, PIPE, OR SUPPORTS
ARE REMOVED, PATCH AND FINISH THE SURFACE AS REQUIRED TO
MATCH THE EXISTING, UNLESS OTHERWISE NOTED.
UNIVERSITY OF MISSOURI - COLUMBIA SITE MAP
PROJECT NOTES: CONTINUED
9. DISCONNECTION OR INTERRUPTION OF ANY MECHANICAL, PLUMBING,
OR ELECTRICAL SYSTEMS MUST BE COORDINATED WITH OWNER'S
REPRESENTATIVE AT LEAST 72 HOURS PRIOR TO WORK BEING
PERFORMED.
10. THE CONTRACTOR SHALL TAKE PHOTOGRAPHS OF INTERIOR AND
EXTERIOR AREAS DOCUMENTING EXISTING CONDITIONS BEFORE
PROCEEDING WITH WORK. ATTENTION SHALL BE FOCUSED ON ANY
EXISTING DAMAGE. ANY SUBSEQUENT DAMAGE OCCURRING DURING
THE CONSTRUCTION PERIOD SHALL BE REPLACED AT THE
CONTRACTORS EXPENSE.
LANDSCAPE NOTES:
1. VEHICLES ARE TO USE DESIGNATED CONSTRUCTION ENTRANCES AS
INDICATED ON DRAWINGS OR CONSTRUCTION DOCUMENTS. IF NO
CONSTRUCTION ROUTE IS INDICATED VEHICLES ARE RESTRICTED TO
SIDEWALKS OR PAVED AREAS. ALL CONSTRUCTION EQUIPMENT AND
OR VEHICLES SHALL VERIFY THE WEIGHT LIMIT AND RESTRICTION ON
PAVEMENT PRIOR TO CONSTRUCTION AND NOTIFY OWNER'S
REPRESENTATIVE OF THE PLANNED ROUTE.
2. THERE SHALL BE NO VEHICLE MOVEMENT IN ANY LANDSCAPED, SHRUB
OR PERENNIAL AREAS, MULCH BED AND/OR TREE CANOPY DRIP AND
ROOT ZONES, WITHOUT PRIOR NOTIFICATION AND APPROVAL FROM
LANDSCAPE SERVICES. LANDSCAPE SERVICES REQUIRES ONE WEEK
NOTICE PRIOR TO ANY VEHICLE MOVEMENT IN THESE AREAS.
3. WHERE ACCESS TO BUILDING REQUIRES CROSSING TURF, MULCH
AREAS, TREE ROOT SYSTEMS, TREE CANOPY ZONES, OR IRRIGATION
SYSTEMS, THE CONTRACTOR SHALL USE ALTURNAMATS BY DICA OR
APPROVED EQUAL.
4. VEHICLE ACCESS SHALL NOT BREAK OR RUB TREE BRANCHES. OWNER
WILL PRUNE TREE BRANCHES TO PROVIDE CLEARANCE AROUND
BUILDING ENTRANCE. OWNER REQUIRES ONE WEEK'S NOTICE FOR
THIS WORK TO BE DONE.
5. DO NOT COMPACT GRADE WITHIN THE DRIP LINE OF TREES. PROVIDE
APPROVED FENCING TO PREVENT DRIVING OR EQUIPMENT PARKING
WITHIN DRIP LINE OF TREES, PRIOR TO CONSTRUCTION OR WORK IN
THE PROJECT AREA. MU'S CAMPUS STANDARD 6' CHAIN LINK FENCE
AND POSTS SHALL BE USED UNLESS OTHERWISE NOTED AND/OR
APPROVED BY LANDSCAPE SERVICES.
I HEREBY CERTIFY THAT DRAWINGS G001, G002,
A400.2, A101 AND/OR SCOPE PACKAGE #2
SPECIFICATION SECTIONS 06 1000, 07 0150.19, 07
5200, 07 6200, AND 07 9200 HAVE BEEN
PREPARED BY ME, OR UNDER MU SUPERVISION.
I FURTHER CERTIFY THAT TO THE BEST OF MY
KNOWLEDGE THESE DRAWINGS AND/OR
SPECIFICATIONS ARE AS REQUIRED BY AND IN
COMPLIANCE WITH BUILDING CODES OF THE
UNIVERSITY OF MISSOURI.
SIGNATURE:
__________________________________________________________
CP
181201 -T
AR
A &
T
AR
A W
OO
DS
A
PA
RT
ME
NT
C
OM
PLE
X - R
OO
F R
EP
LA
CE
ME
NT
, 04/05/18 IS
SU
ED
F
OR
B
ID
UM CONSULTANT
PROCEDURES AND
DESIGN GUIDELINES:
CURRENT EDITION
IBC: 2015
IEBC: 2015
IMC: 2015
IPC: 2015
IFC: 2015
IFGC 2015
NEC: 2014
NFPA 13: 2013
NFPA 14: 2013
NFPA 20: 2013
NFPA 45: 2015
NFPA 72: 2013
NFPA 90A: 2015
NFPA 96: 2014
NFPA 99: 2005
NFPA 101: 2015
NFPA 110: 2013
ASHRAE 90.1: 2013
ASME A17.1S: 2005
ADA 2010
INDEX OF DRAWINGS
REVISION DESCRIPTION
REVISION DELTA # 1 2 3 4 5 6 7
SH
EE
T
NU
MB
ER
SHEET TITLE
04
/0
5/2
01
8 F
OR
B
ID
A
ND
CO
NS
TR
UC
TIO
N
G001
COVER SHEET (THIS SHEET)
Δ
A101 SITE PLAN Δ
A102 ROOF PLANS Δ
A501 DETAILS Δ
CODES AND
STANDARDS
DATE: PROJECT NO.:
CAMPUS FACILITIES
UNIVERSITY OF MISSOURI
Planning, Design,
& Construction
Design Services
THE CURATORS OF THE
UNIVERSITY OF MISSOURI
FOR:
TARA & TARA WOODS APARTMENT COMPLEX
COLUMBIA, BOONE COUNTY, MISSOURI 65211
ROOF REPLACEMENT
APRIL 5, 2018 CP181201
DESIGN CONSULTANTS:
ARCHITECTURAL
DESIGN SERVICES
GENERAL SERVICES BUILDING
900 E STADIUM BLVD
COLUMBIA, MO 65211
573-882-6800
OWNER'S REPRESENTATIVE
ED DRANE
GENERAL SERVICES BUILDING
900 E STADIUM BLVD
COLUMBIA, MO 65211
SEE SHEET A101 FOR STAGING
INFORMATION AND PROJECT
NOTES
PROJECT NOTES
A. PROJECT NOTES APPLY TO ALL SHEETS OF DRAWINGS.
B. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO
ORDER OF MATERIALS OR START OF CONSTRUCTION.
C. CAUTION: THIS PROJECT MAY CONTAIN HAZARDOUS MATERIALS. NO
WORK MAY PROCEED WITHOUT CONTRACTOR REVIEW OF EH&S
HAZARDOUS MATERIALS SURVEY OR WRITTEN APPROVAL FROM
AUTHORIZED EH&S PERSONNEL. CONTACT DESIGN
SERVICES (573-882-6800) TO OBTAIN A COPY OF THE REPORT, OR IF
THERE ARE QUESTIONS REGARDING HAZARDOUS MATERIALS. THE
MANAGEMENT OF HAZARDOUS MATERIALS ABATEMENT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR AND BE CONDUCTED IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS.
D. CONTRACTOR SHALL SWEEP AN AREA WITHIN 20' OF BUILDING
PERIMETER FOR NAILS AND SHINGLE PIECES.
E. CONTRACTOR TO PROTECT ALL GROUND MOUNTED MECHANICAL
EQUIPMENT WHILE CONSTRUCTION IS IN PROGRESS ABOVE.
F. PROVIDE OVERHEAD PROTECTION AT ENTRYWAYS WHILE
CONSTRUCTION IS IN PROGRESS ABOVE.
8'
8'
12
'
1/8
"0
4'
10
'
16
'
4'
6'
12
'
2'
20
'2
4'
01
/4
"
3/8
"0 4
'
2'
3'
2'
4'
1'
6'
08'
3/4
"
1'
1/2
"
3'
02
'
2'
15
0'
1"
3'
4'
1'
5'
6'
0
1-1
/2
"0
1'
1'
2'
03
"
1:1
00
10
'
10
0'
20
'
50
'1
:5
00
30
'
PROJECT NUMBER
SHEET
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
CA
MP
US
FAC
ILIT
IES
UN
IV
ER
SIT
Y O
F M
IS
SO
UR
I
Plan
nin
g, D
esig
n,
& C
on
stru
ctio
n
Design S
ervices
ARCHITECT -
Th
e P
ro
fe
ssio
na
l A
rch
ite
cts se
al a
nd
sig
na
tu
re
a
ffixe
d to
th
is sh
ee
t a
pp
lie
s o
nly to
th
e m
ate
ria
l a
nd
in
fo
rm
atio
n sh
ow
n o
n th
is
sh
ee
t. A
ll d
ra
win
gs, in
stru
me
nts, o
r o
th
er
do
cu
me
nts n
ot e
xh
ib
itin
g th
is se
al sh
all n
ot
be
co
nsid
ere
d p
re
pa
re
d b
y th
is a
rch
ite
ct, a
nd
th
is a
rch
ite
ct e
xp
re
ssly d
iscla
im
s a
ny a
nd
a
ll
re
sp
on
sib
ility fo
r su
ch
p
la
ns, d
ra
win
gs, o
r
do
cu
me
nts n
ot e
xh
ib
itin
g th
is se
al.
Th
is D
ocu
me
nt is in
te
nd
ed
to
b
e sig
ne
d
dig
ita
lly. If n
o d
ig
ita
l sig
na
tu
re
is a
tta
ch
ed
to
th
is file
, th
is m
ed
ia
sh
ou
ld
n
ot b
e co
nsid
ere
d
a ce
rtifie
d d
ocu
me
nt.
CP181201
TA
RA
&
T
AR
A W
OO
DS
A
PA
RT
ME
NT
C
OM
PLE
X
CO
LU
MB
IA
, B
OO
NE
C
OU
NT
Y, M
IS
SO
UR
I 65211
RO
OF
R
EP
LA
CE
ME
NT
SIT
E P
LA
N
A101
JEFFREY GEORGE HARPER
MO# A-8123
JE
JG
H
04/05/18
FO
R B
ID
A
ND
C
ON
ST
RU
CT
IO
N
LEGEND
BLDG. 100
SCALE:
SITE PLAN
1" = 50'
MAINT.
SHOP
BLDG. 100
TYPE A
BLDG. 200
TYPE A
BLDG. 300
TYPE A
BLDG. 400
TYPE A
BLDG. 500
TYPE A
BLDG. 600
TYPE A
BLDG. 900
TYPE A
BLDG. 800
TYPE A
BLDG. 700
TYPE A
BLDG. 1100
TYPE A
BLDG. 1000
TYPE A
BLDG. 1300
TYPE B
BLDG. 1200
TYPE B
BLDG. 1400
TYPE B
BLDG. 1500
TYPE B
BLDG.
1600
A
S
H
L
A
N
D
R
O
A
D
E
A
S
T
C
A
M
P
U
S
D
R
IV
E
E
A
S
T
S
T
A
D
IU
M
B
L
V
D
.
ADDITIONAL
CHIMNEY
TARA OFFICE
ALTERNATE #2
BUILDING NUMBER
TYPE A PLAN TYPE - SEE SHEET A102
STAGING
AREA FOR
TARA
OFFICE,
BLDGS 700
& 800
STAGING
AREA FOR
MAINT. SHOP,
BLDGS 900,
1000 & 1100
STAGING
AREA FOR
BLDGS
100, 200 &
600
STAGING
AREA FOR
BLDGS 300,
400 & 500
STAGING AREA FOR
BLDGS 1200, 1300,
1400, 1500 & 1600
8'
8'
12
'
1/8
"0
4'
10
'
16
'
4'
6'
12
'
2'
20
'2
4'
01
/4
"
3/8
"0 4
'
2'
3'
2'
4'
1'
6'
08'
3/4
"
1'
1/2
"
3'
02
'
2'
15
0'
1"
3'
4'
1'
5'
6'
0
1-1
/2
"0
1'
1'
2'
03
"
1:1
00
10
'
10
0'
20
'
50
'1
:5
00
30
'
PROJECT NUMBER
SHEET
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
CA
MP
US
FAC
ILIT
IES
UN
IV
ER
SIT
Y O
F M
IS
SO
UR
I
Plan
nin
g, D
esig
n,
& C
on
stru
ctio
n
Design S
ervices
ARCHITECT -
Th
e P
ro
fe
ssio
na
l A
rch
ite
cts se
al a
nd
sig
na
tu
re
a
ffixe
d to
th
is sh
ee
t a
pp
lie
s o
nly to
th
e m
ate
ria
l a
nd
in
fo
rm
atio
n sh
ow
n o
n th
is
sh
ee
t. A
ll d
ra
win
gs, in
stru
me
nts, o
r o
th
er
do
cu
me
nts n
ot e
xh
ib
itin
g th
is se
al sh
all n
ot
be
co
nsid
ere
d p
re
pa
re
d b
y th
is a
rch
ite
ct, a
nd
th
is a
rch
ite
ct e
xp
re
ssly d
iscla
im
s a
ny a
nd
a
ll
re
sp
on
sib
ility fo
r su
ch
p
la
ns, d
ra
win
gs, o
r
do
cu
me
nts n
ot e
xh
ib
itin
g th
is se
al.
Th
is D
ocu
me
nt is in
te
nd
ed
to
b
e sig
ne
d
dig
ita
lly. If n
o d
ig
ita
l sig
na
tu
re
is a
tta
ch
ed
to
th
is file
, th
is m
ed
ia
sh
ou
ld
n
ot b
e co
nsid
ere
d
a ce
rtifie
d d
ocu
me
nt.
CP181201
TA
RA
&
T
AR
A W
OO
DS
A
PA
RT
ME
NT
C
OM
PLE
X
CO
LU
MB
IA
, B
OO
NE
C
OU
NT
Y, M
IS
SO
UR
I 65211
RO
OF
R
EP
LA
CE
ME
NT
RO
OF
PL
AN
S
A102
JEFFREY GEORGE HARPER
MO# A-8123
JE
JG
H
04/05/18
FO
R B
ID
A
ND
C
ON
ST
RU
CT
IO
N
INDICATES NOTES LOCATED ON PLAN
ARCHITECTURAL RENOVATION NOTES
INDICATES NOTES LOCATED ON PLAN
ARCHITECTURAL DEMOLITION NOTES
1. ROOFING:
A. REMOVE EXISTING ASPHALT SHINGLES, UNDERLAYMENT, AND RELATED
METAL FLASHING IN ENTIRETY. SOME BUILDINGS HAVE TWO LAYERS OF
SHINGLES.
B. REMOVE EXISTING MODIFIED BITUMEN ROOFING MEMBRANE.
C. REMOVE EXISTING ROOF VENT.
D. REMOVE SHEET METAL DIVERTER.
E. EXISTING PLUMBING VENT TO REMAIN. REMOVE FLASHING.
F. EXISTING SQUARE ROOF VENT TO REMAIN.
G. EXISTING CHIMNEY TO REMAIN. REMOVE EXISTING STEP FLASHING.
H. ALTERNATE #1 - REMOVE EXISTING CHIMNEY BRICK AND FLUE TO BRICK
LINE BELOW EXISTING GUTTER. SEE DETAIL 4/A501.
SCALE
APARTMENT BUILDING
TYPE A - ROOF PLAN
4
A102
1/8" = 1'-0"
SCALE
APARTMENT BUILDING
TYPE B - ROOF PLAN
3
A102
1/8" = 1'-0"
SCALE
MAINT. SHOP - ROOF PLAN
2
A102
1/8" = 1'-0" SCALE
TARA OFFICE - ROOF PLAN
1
A102
1/8" = 1'-0"
6" 137'-5" 6"
6" 98'-9" 6"
32'-11"
39'-0"
14'-9"
23'-6
7
8
"
14'-9"
13'-3"
23'-6
7
8
"
14'-10"
23'-6
7
8
"
38'-4
3
4
"14'-8
1
8
"
7'-0"
4'-4"
14'-8"
19'-3
3
8
"23'-6
7
8
"
EXISTING STACKS
AND SUPPORTS
TO REMAIN
PORCH DECK
BELOW
PORCH DECK
BELOW
GABLE END
MODIFIED
BITUMEN
ROOF - 1:12
SLOPE
LOWER ROOF
N.I.C.
3
A501
2
A501
±
1
5
'
-
1
"
3
A
5
0
1
3
A
5
0
1
ADDITIONAL CHIMNEY
TO REMAIN AT
BUILDING 200 ONLY
LOWER ROOF N.I.C.
3
A
5
0
1
3
A
5
0
1
3
A501
2
A501
1
A501
1
A501
4
A501
CHIMNEY
ALTERNATE #1
1
A501
1
A501
5
A501
TARA OFFICE
ALTERNATE #2
TARA OFFICE
ALTERNATE #2
6"
6"
45'-3"
6"
4
A501
CHIMNEY
ALTERNATE #1 5
A501
4
A501
CHIMNEY
ALTERNATE #1 5
A501
4
A501
CHIMNEY
ALTERNATE #1 5
A501
1. ROOFING:
A. INSTALL NEW UNDERLAYMENT, EAVE PROTECTION PER
MANUFACTURER'S INSTALLATION INSTRUCTIONS. INSTALL ASPHALT
SHINGLES AS SPECIFIED.
B. INSTALL MODIFIED BITUMEN ROOFING MEMBRANE OVER EXISTING LOW
SLOPE DECK.
C. INSTALL 2X NAILER BELOW HOLE WHERE ROOF VENT REMOVED. INSTALL
NEW WOOD DECK TO INFILL OPENING AND SCREW TO 2X NAILER.
D. INSTALL SHEET METAL CRICKET AT CHIMNEY. SEE DETAIL 1/A501.
E. INSTALL NEW LEAD FLASHING AT PLUMBING VENTS, TYPICAL.
F. INSTALL NEW STEP FLASHING AT CHIMNEY.
G. ALTERNATE #1 - INFILL WOOD FRAMING AND DECK WHERE CHIMNEY
REMAINING INSTALL SHINGLES AND EXTEND GUTTER. INSTALL SHEET
METAL CAP OVER REMAINING CHIMNEY - SLOPE TO DRAIN. SEE DETAIL
5/A501.
H. CUT BACK EXISTING SHEATHING TO ALLOW FOR
3
4
" AIR GAP TO VENT AT
RIDGE. CUT BACK SHEATHING AT HIP SIDES ONLY FROM RIDGE TO POINT
HALFWAY DOWN.
I. RIDGE VENT AS SPECIFIED. EXTEND RIDGE VENT DOWN HIP SIDES ALL
THE WAY TO THE EAVE.
1C
1C
1C
1C
1C
1C
1C
1C
1C
1C
1E
1E
1E
1E
1E
1E
1E
1E
1E
1E
1E
1E
1A
1A
1A
1A
1I
1I
SIM
1H
1H
1H
1H
1E
1E
TYP.
1I
1E
1E
1I
1D
1D
42'-8"
6"
1G
1H
1F
1G
1G
1H
1F
1G
1D
1D
1D
1E
1E
1I
1D
1D
1G
1H
1F
1G
1D
1D
1G
1H
1F
1G
1I
1H
1H
1A
1A
TYP.
1I
SIM.
1H
1H
1C
1C
1C
1C
1C
1C
1E
1E
1E
1E
1E
1E
1E
1E
1E
1E
1A
1A
1I
±
1
6
'
-
0
"
1A
1A
NO RIDGE VENT
AT MAINT SHOP
1A
1A
NO RIDGE VENT
AT TARA OFFICE
1B
1B
1E
1G
1A
1A
1A
1A
1F
1G
1F
1F 1F
1F
1E
1E
8'
8'
12
'
1/8
"0
4'
10
'
16
'
4'
6'
12
'
2'
20
'2
4'
01
/4
"
3/8
"0 4
'
2'
3'
2'
4'
1'
6'
08'
3/4
"
1'
1/2
"
3'
02
'
2'
15
0'
1"
3'
4'
1'
5'
6'
0
1-1
/2
"0
1'
1'
2'
03
"
1:1
00
10
'
10
0'
20
'
50
'1
:5
00
30
'
PROJECT NUMBER
SHEET
DR
AW
N B
Y:
CH
EC
KE
D B
Y:
CA
MP
US
FAC
ILIT
IES
UN
IV
ER
SIT
Y O
F M
IS
SO
UR
I
Plan
nin
g, D
esig
n,
& C
on
stru
ctio
n
Design S
ervices
ARCHITECT -
Th
e P
ro
fe
ssio
na
l A
rch
ite
cts se
al a
nd
sig
na
tu
re
a
ffixe
d to
th
is sh
ee
t a
pp
lie
s o
nly to
th
e m
ate
ria
l a
nd
in
fo
rm
atio
n sh
ow
n o
n th
is
sh
ee
t. A
ll d
ra
win
gs, in
stru
me
nts, o
r o
th
er
do
cu
me
nts n
ot e
xh
ib
itin
g th
is se
al sh
all n
ot
be
co
nsid
ere
d p
re
pa
re
d b
y th
is a
rch
ite
ct, a
nd
th
is a
rch
ite
ct e
xp
re
ssly d
iscla
im
s a
ny a
nd
a
ll
re
sp
on
sib
ility fo
r su
ch
p
la
ns, d
ra
win
gs, o
r
do
cu
me
nts n
ot e
xh
ib
itin
g th
is se
al.
Th
is D
ocu
me
nt is in
te
nd
ed
to
b
e sig
ne
d
dig
ita
lly. If n
o d
ig
ita
l sig
na
tu
re
is a
tta
ch
ed
to
th
is file
, th
is m
ed
ia
sh
ou
ld
n
ot b
e co
nsid
ere
d
a ce
rtifie
d d
ocu
me
nt.
CP181201
TA
RA
&
T
AR
A W
OO
DS
A
PA
RT
ME
NT
C
OM
PLE
X
CO
LU
MB
IA
, B
OO
NE
C
OU
NT
Y, M
IS
SO
UR
I 65211
RO
OF
R
EP
LA
CE
ME
NT
DE
TA
ILS
A501
JEFFREY GEORGE HARPER
MO# A-8123
JE
JG
H
04/05/18
FO
R B
ID
A
ND
C
ON
ST
RU
CT
IO
N
SCALE
CHIMNEY CRICKET DETAIL
1
A501
1" = 1'-0"SCALE
MANSARD ROOF SECTION
2
A501
3" = 1'-0"
SCALE
RIDGE SECTION
3
A501
3" = 1'-0"
2
A501
MANSARD ROOF SECTION
GUTTER TO REMAIN
NEW STEP FLASHING
NEW SHEET METAL
CRICKET
5:12
SLOPE
ASPHALT
SHINGLES
EXISTING CHIMNEY
TO REMAIN
RIDGE VENT
CUT BACK EXISTING
SHEATHING FOR VENT
ASPHALT SHINGLES
EXISTING SHEATHING
TO REMAIN
RIDGE BEAM
1
"
ASPHALT SHINGLES
EXISTING SHEATHING
TO REMAIN
PRE-FINISHED
DRIP EDGE
6 NAILS PER SHINGLE
AT MANSARD
PORTIONS
REPLACE GUTTER
SCREENS
CLEAN GUTTERS
AT END OF
ROOFING
EXISTING GUTTER
TO REMAIN
EXISTING SOFFIT VENT
TO REMAIN
2
"
3
4
"
12
5
12
5
2
"
SCALE
CHIMNEY ALTERNATE #1
DEMOLITION PHOTO
4
A501
NOT TO SCALE
SCALE
CHIMNEY ALTERNATE #1
RENOVATION RENDERING
5
A501
NOT TO SCALE
AREA TO BE REMOVED
IN ENTIRETY - REMOVE
BRICK, FLUE AND
METAL FLASHING AT
ALL APARTMENT
BUILDING CHIMNEYS
EXCEPT FOR THE
ADDITIONAL CHIMNEY
AT BUILDING #200
INSTALL NEW METAL
CAP - SLOPE TO DRAIN
INFILL WOOD DECK,
SHINGLES, AND GUTTER
WHERE CHIMNEY
REMOVED
DETAIL AT RIDGE AND HIP SIDES - CUT
BACK SHEATHING AT HIP SIDES ONLY
FROM RIDGE DOWN TO ONE HALF THE
DISTANCE TO THE EAVE - RIDGE VENT TO
CONTINUE DOWN TO EAVE
VE
RIF
Y
± 6"
(SEE DETAILS
4/A501 AND 5/A501
FOR ALTERNATE #1)