PAGE 2 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11 Addendum #1

Work to be performed Subcontractor Name, City, State __________________________________________________________________________ Mechanical Contractor: Electrical Contractor: Temperature Controls Contractor:

3. BID FOR LUMP SUM CONTRACT: a. Revise paragraph “6-a SUPPLIER DIVERSITY PARTICIPATION GOALS” to read:

The Contractor shall have as a goal subcontracting with Minority Business Enterprise (MBE), Women Business Enterprise (WBE), Disadvantage Business Enterprise (DBE), and Veteran Owned Business of Ten Percent (10%) of the awarded contract price for work to be performed for all four combined, and a goal subcontracting with Service Disabled Veteran Owned Business of Three Percent (3%) of awarded contract price for work to be performed.

Specifications:

1. 23 84 13 – Humidifiers:

a. Modify 2.2 to read as follows:

A. Steam Header / Separator: ASTM A666, Type 304 stainless steel, with integral heat exchanger which shall provide atmospheric condensate vaporizing and pressurized condensate return.

1. All dispersion tube-generated condensate that falls to the heat exchanger in the header shall be vaporized into humidification steam.

2. As condensate is vaporized in the header, pressurized condensate created in the heat exchanger shall return to main without need for additional pumps, valves, or controls.

NOTE: Contractor’s Option to provide a humidifier which complies with this specification except for the above described condensate management. In this case, Contractor shall consult humidifier manufacturer regarding required vented condensate reservoir, and provide submittal information for the condensate reservoir for Engineer’s review.

B. Humidifier Steam Control Valve: Comply with ANSI B16.15 Class 250; equal percentage flow characteristics; brass or bronze body globe valve with stainless steel seat, stem and plug; sized to meet humidification requirements.

1. Actuator: Electric modulating with spring return; normally closed. 2. Actuator: As specified in Division 23 Section “Control Systems.”

C. Heat Exchanger Control Valve: Two-position, normally closed, solenoid operated, on-off steam valve. Valve shall respond to a signal from a humidistat via 24 VAC signal.

Page 3: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11 Addendum #1

b. Remove 2.3 A Vapor Hose Kit in its entirety.

c. Add 2.3 A.1 to read: Humidifier panel assembly shall be contained within a Type 304 stainless steel metal casing to allow convenient mounting in air handler casings.

d. Modify 2.3 A.5 to read: Steam shall discharged in diametrically opposite directions, perpendicular to airflow, and shall be absorbed into the airstream such that no moisture accumulates on interior air handling unit surfaces more than 12 inches beyond the centerline of the steam dispersion grid at 500 fpm face velocity. The dispersion tube quantity and spacing, and vapor outlet ports quantity and spacing, shall be factory-engineered to meet this absorption requirement.

e. Modify 2.4 Accessory Hardware to read:

A. Steam Trap: Humidifier shall be provided with one float/thermostatic type trap

complying with Division 23 Section “Steam and Condensate Piping.”

B. Inlet Strainer: Humidifier shall be provided with one inlet strainer complying with Division 23 Section “Steam and Condensate Piping.”

f. Add 3.2 A to read: Humidifier shall be factory installed within air handling unit by air

handling unit manufacturer.

Drawings:

1. X-1: a. MODIFY Enlarged Site Plan: Revise Contractor parking area.

2. M000:

a. ADD Floor Protection Notes.

3. M001: a. MODIFY General Note 3. b. MODIFY Keyed Notes 5, 6, 7, and 8. c. ADD Keyed Notes 9, 10, 11, and 12. d. MODIFY Fifth Floor Temporary Cooling and Construction Phasing Plan: Revise

construction phase boundaries.

4. MD101: a. MODIFY First Floor Demolition Plan: Revise construction phase boundary. b. MODIFY Keyed Note 8.

5. MD102:

a. MODIFY Fifth Floor Ductwork Demolition Plan i. Remove ductwork demolition from fume hood ductwork in Labs M503 and M538. ii. Revise ductwork demolition work in M526 Research Office. iii. Remove keyed note 4 and renumber keyed notes accordingly.

6. MD103:

a. MODIFY General Note 3.

7. M101: a. MODIFY First Floor Piping New Work Plan: Revise construction phase boundaries. b. MODIFY Keyed Note 20. c. MODIFY Partial Fourth Floor Piping New Work Plan: Revise hot water supply and return

riser size.

Page 4: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

PAGE 4 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11 Addendum #1

8. M102: a. MODIFY Fifth Floor Ductwork New Work Plan:

i. Remove manual volume dampers from fume hood ductwork in Labs M503 and M538.

ii. Revise supply and exhaust layout in Labs M529 and M531. b. ADD Keyed Note 12. c. MODIFY note on Detail 2 – Exhaust Duct Fitting Detail.

9. M201:

a. MODIFY Enlarged Fifth Floor Ductwork New Work Plan: i. Clarify shoe tap fitting on cold supply air duct serving north wing. ii. Revise supply air and exhaust air ductwork to maintain access to existing

electrical bus duct in Mechanical Room M524. b. MODIFY Enlarged Fifth Floor Piping New Work Plan:

i. Revise hot water supply and return layout and valve requirements in Mechanical Room M524.

c. ADD Keyed Notes 21 and 22.

10. M301: a. MODIFY Section D: Revise exhaust riser to provide required access to existing electrical

bus duct in Mechanical Room M524. b. ADD Keyed Note 2.

11. M401:

a. MODIFY Chilled Water Flow Diagram. b. MODIFY Heating Hot Water Flow Diagram.

12. M501:

a. MODIFY Detail 3 – AHU Humidifier Detail. b. MODIFY AHU-11 Air Handling Unit Components List: Remove reference to unit-mounted

outside air damper from component 1. 13. M601:

a. MODIFY Motorized Damper Schedule. Omit cold deck damper. b. MODIFY Humidifier Schedule: Revise note 2.

14. M701:

a. MODIFY AHU-11 Control Diagram: i. Revise to show new single duct VAV terminal units for north wing. ii. Revise location of cooling coil temperature sensor. iii. Revise humidifier sequence of operation.

15. M702: a. MODIFY VAV Box with Reheat Control Diagram:

i. Add occupancy sensor. ii. Add Keyed Note 10.

Attachments:

1. X-1 – STAGING PLAN 2. M000 – MECHANICAL SYMBOLS, ABBREVIATIONS, AND GENERAL AND CONSTRUCTION

PHASING NOTES 3. M001 – FIFTH FLOOR TEMPORARY COOLING AND CONSTRUCTION PHASING PLAN 4. MD101 – FIRST FLOOR DEMOLITION PLAN 5. MD102 – FIFTH FLOOR DEMOLITION PLAN 6. MD103 – ENLARGED DEMOLITION PLANS 7. M101 – PIPING NEW WORK PLANS 8. M102 – FIFTH FLOOR DUCTWORK NEW WORK PLAN

Page 5: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

PAGE 5 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11 Addendum #1

9. M201 – ENLARGED NEW WORK PLANS 10. M301 – SECTIONS 11. M401 – HYDRONIC FLOW DIAGRAMS 12. M501 – DETAILS 13. M601 – SCHEDULES 14. M701 – CONTROLS 15. M702 – CONTROLS

END OF ADDENDUM 1

Page 6: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Issued on 01/20/2017 with Addendum 1

1.A - 1

SECTION 1.A BID FOR LUMP SUM CONTRACT Date:____________________________ BID OF (hereinafter called "Bidder") a corporation* organized and existing under laws of the State of , a partnership* consisting of , an individual* trading as , a joint venture* consisting of . *Insert Corporation(s), partnership or individual, as applicable.

TO: Curators of the University of Missouri c/o Assistant Vice Chancellor – Facilities

Room L100 General Services Building University of Missouri – Columbia Columbia, Missouri 65211

1. Bidder, in compliance with invitation for bids for construction work in accordance with Drawings and Specifications prepared by Ross & Baruzzini, Inc., entitled "MEDICAL SCIENCE BUILDING – REPLACE AHU-11", project number CP161791, dated January 11, 2017 having examined Contract Documents and site of proposed work, and being familiar with all conditions pertaining to construction of proposed project, including availability of materials and labor, hereby proposes to furnish all labor, materials and supplies to construct project in accordance with Contract Documents, within time set forth herein at prices stated below. Prices shall cover all expenses, including taxes not covered by the University of Missouri’s tax exemption status, incurred in performing work required under Contract documents, of which this Bid is a part.

Bidder acknowledges receipt of following addenda:

Addendum No. Dated Addendum No. Dated Addendum No. Dated Addendum No. Dated 2. In following Bid(s), amount(s) shall be written in both words and figures. In case of discrepancy between words and figures, words shall govern.

3. BID PRICING

a. Base Bid: The Bidder agrees to furnish all labor, materials, tools, and equipment required to remove an existing air handling unit and associated ductwork, piping, conduits, controls, and auxiliary electrical equipment and install a new air handling unit and associated ductwork, piping, conduits, controls, and auxiliary electrical equipment, including the installation of new chilled water and heating hot water piping and conversion of the 5th floor north wing from constant volume dual duct to variable volume with hot water reheat; all as indicated on the Drawings and described in these Specifications for sum of:

DOLLARS ($ ).

Page 7: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Issued on 01/20/2017 with Addendum 1

1.A - 2

b. Additive Alternate Bids: NOT APPLICABLE c. Unit Prices: NOT APPLICABLE

4. PROJECT COMPLETION

a. Contract Period - Contract period begins on the day the Contractor receives unsigned Contract, Performance Bond, Payment Bond, and "Instructions for Execution of Contract, Bonds, and Insurance Certificates." Bidder agrees to complete project within one hundred and fifty (150) calendar days from receipt of aforementioned documents. Fifteen (15) calendar days have been allocated in construction schedule for receiving aforementioned documents from Bidder.

b. Commencement - Contractor agrees to commence work on this project after the "Notice to Proceed" is issued by the Owner. "Notice to Proceed" will be issued within seven (7) calendar days after Owner receives properly prepared and executed Contract documents listed in paragraph 4.a. above. c. Special scheduling requirements:

1.) Work associated with demolition of existing piping and installation of new piping on first floor shall be scheduled to occur between March 4, 2017 and March 12, 2017. Scheduled outage of heating hot water and chilled water systems shall occur during this time period. See drawings MD101 and M101 for affected areas.

2.) All equipment shutdowns and scheduling of work within occupied spaces shall be scheduled with the Owner’s Representative a minimum of 2 weeks in advance of the outage.

3.) Saw-cutting, core-drilling, use of hammer drills, and installation of powder-actuated fasteners shall occur only during the following time periods to minimize disruption of adjacent work and clinical study areas: 6:00 a.m. to 8:00 a.m., or 5:00 p.m. to 10:00 p.m.

4.) Prior to demolition, Contractor shall provide mobile cooling units to temporary cool select spaces. Units shall remain in place for entire AHU-11 shutdown duration. See drawing M001 for affected areas.

5.) Prior to demolition, Contractor shall coordinate with Owner’s Representative to obtain Owner-furnished window AC units salvaged from the Lathrop and Laws Demolition project to temporarily cool spaces with operable windows. Units shall remain in place for entire AHU-11 shutdown duration. See drawing M001 for affected areas.

6.) Construction schedule shall allow a minimum of two (2) weeks for system testing and balancing.

7.) Construction schedule shall allow a minimum of two (2) weeks for the Owner-provided programming and startup of Johnson Controls Metasys temperature controls system.

5. SUBCONTRACTOR LIST:

Bidder hereby certifies that the following subcontractors will be used in performance of Work:

NOTE: Failure to list subcontractors for each category of work identified on this form or listing more than one subcontractor for any category of work without designating the portion of work performed by each shall be grounds for rejection of bid. List name, city, and state of designated subcontractor, for each category of work listed in Bid For Lump Sum Contract. If work within a category will be performed by more than one subcontractor, Bidder shall provide name, city, and state of each subcontractor and specify exact portion of work to be performed by each. If acceptance/non-acceptance of Alternates will affect designation of a subcontractor, Bidder shall provide information, for each affected category, with this bid form. If Bidder intends to perform any designated subcontract

Page 8: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Issued on 01/20/2017 with Addendum 1

1.A - 3

work by using Bidder's own employees, then Bidder shall list their own name, city, and state. The bidder may petition the Owner to change a listed subcontractor only within 48 hours of the bid opening. See Information For Bidders Section 16 List of Subcontractors for requirements.

_______________________________________________________________________________________________ Work to be performed Subcontractor Name, City, State _______________________________________________________________________________________________

Mechanical Contractor: _ Electrical Contractor: _ Temperature Controls Contractor: ________

6. SUPPLIER DIVERSITY PARTICIPATION GOALS

a. The Contractor shall have as a goal subcontracting with Minority Business Enterprise (MBE), Women Business Enterprise (WBE), Disadvantage Business Enterprise (DBE), and Veteran Owned Business of Ten Percent (10%) of the awarded contract price for work to be performed for all four combined, and a goal subcontracting with Service Disabled Veteran Owned Business of Three Percent (3%) of awarded contract price for work to be performed.

b. Requests for waiver of this goal shall be submitted on the attached Application For Waiver form. A determination by the Director of Facilities Planning & Development, UM, that a good faith effort has not been made by Contractor to achieve above stated goal may result in rejection of bid.

c. The Undersigned proposes to perform work with following Supplier Diversity participation level: MBE PERCENTAGE PARTICIPATION: _____________________ percent ( %) SDVE PERCENTAGE PARTICIPATION: _____________ percent ( %) WBE, DBE, and/or VETERAN PERCENTAGE PARTICIPATION:___________ percent ( %)

d. A Supplier Diversity Compliance Evaluation form shall be submitted with this bid for each diverse subcontractor to be used on this project.

7. BIDDER'S ACKNOWLEDGMENTS

a. Bidder declares that he has had an opportunity to examine the site of the work and he has examined Contract Documents therefore; that he has carefully prepared his bid upon the basis thereof; that he has carefully examined and checked bid, materials, equipment and labor required thereunder, cost thereof, and his figures therefore. Bidder hereby states that amount, or amounts, set forth in bid is, or are, correct and that no mistake or error has occurred in bid or in Bidder's computations upon which this bid is based. Bidder agrees that he will make no claim for reformation, modifications, revisions or correction of bid after scheduled closing time for receipt of bids.

b. Bidder agrees that bid shall not be withdrawn for a period of sixty (60) days after scheduled closing time for receipt of bids.

Page 9: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Issued on 01/20/2017 with Addendum 1

1.A - 4

c. Bidder understands that Owner reserves right to reject any or all bids and to waive any informalities in bidding.

d. Accompanying the bid is a bid bond, or a certified check, or an irrevocable letter of credit, or a cashier's check payable without condition to "The Curators of the University of Missouri" which is an amount at least equal to five percent (5%) of amount of largest possible total bid herein submitted, including consideration of Alternates.

e. Accompanying the bid is a Bidder's Statement of Qualifications. Failure of Bidder to submit the Bidder's Statement of Qualifications with the bid may cause the bid to be rejected. Owner does not maintain Bidder's Statements of Qualifications on file.

f. It is understood and agreed that bid security of two (2) lowest and responsive Bidders will be retained until Contract has been executed and an acceptable Performance Bond and Payment Bond has been furnished. It is understood and agreed that if the bid is accepted and the undersigned fails to execute the Contract and furnish acceptable Performance/Payment Bond as required by Contract Documents, accompanying bid security will be realized upon or retained by Owner. Otherwise, the bid security will be returned to the undersigned.

8. BIDDER'S CERTIFICATE

Bidder hereby certifies:

a. His bid is genuine and is not made in interest of or on behalf of any undisclosed person, firm or corporation, and is not submitted in conformity with any agreement or rules of any group, association or corporation.

b. He has not directly or indirectly induced or solicited any other bidder to put in a false or sham bid.

c. He has not solicited or induced any person, firm or corporation to refrain from bidding.

d. He has not sought by collusion or otherwise to obtain for himself any advantage over any other Bidder or over Owner.

e. He will not discriminate against any employee or applicant for employment because of race, color, religion, sex or national origin in connection with performance of work.

f. By virtue of policy of the Board of Curators, and by virtue of statutory authority, a preference will be given to materials, products, supplies, provisions and all other articles produced, manufactured, mined or grown within the State of Missouri. By virtue of policy of the Board of Curators, preference will also be given to all Missouri firms, corporations, or individuals, all as more fully set forth in "Information For Bidders."

Page 10: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Issued on 01/20/2017 with Addendum 1

1.A - 5

9. BIDDER'S SIGNATURE

Note: All signatures shall be original; not copies, photocopies, stamped, etc.

Authorized Signature Date

Printed Name Title

Company Name

Mailing Address

City, State, Zip

Phone No. Federal Employer ID No.

Fax No. E-Mail Address

Circle one: Individual Partnership Corporation Joint Venture

If a corporation, incorporated under the laws of the State of__________

Licensed to do business in the State of Missouri? ____yes _____no

(Each Bidder shall complete bid form by manually signing on the proper signature line above and supplying required information called for in connection with the signature. Information is necessary for proper preparation of the Contract, Performance Bond and Payment Bond. Each Bidder shall supply information called for in accompanying "Bidder's Statement of Qualifications.")

END OF SECTION

Page 11: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Medical Science Building – Replace AHU-11

Date: January 20, 2017 University of Missouri

Addendum 1 MU Project No. CP 161791

HUMIDIFIERS 238413 - 1

SECTION 238413 - HUMIDIFIERS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary

Conditions and Division 01 Specification Sections, apply to this Section.

B. 23 0100 “Basic Mechanical Requirements,” and Section 23 0500 “Basic Mechanical Materials

and Methods” all apply to the work of this Section as if fully repeated herein.

1.2 SUMMARY

A. This Section includes the following types of humidifiers:

1. Direct steam injection.

B. Related Sections: The following Sections contain requirements that relate to this Section:

1. Division 23 Section “Modular Air-Handling Units” for air handlers which will house

humidifier steam dispersion grids.

2. Division 23 Section “Steam and Condensate Piping” for steam and condensate lines,

steam traps, strainers, and other specialties associated with the humidifiers.

3. Division 23 Section “Control Systems” for humidistats and humidification controls.

1.3 SUBMITTALS

A. Product data including rated capacities of selected models, weights (shipping, installed, and

operating), supports, weight on each support, required clearances, furnished specialties, and

accessories.

B. Shop Drawings: Detail fabrication and installation of humidifiers. Include piping details, plans,

elevations, sections, details of components, manifolds, injection and dispersion elements, and

attachments to other work. Show support locations, type of support, weight on each support,

required clearances, and other details.

C. Field quality-control test reports.

D. Operation and Maintenance Data: For humidifiers to include in operation and maintenance

manuals specified in Division 01. Include detailed manufacturer’s instructions on startup,

shutdown, troubleshooting, preventive maintenance, and servicing. Include parts list and list of

accessories.

Page 12: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Medical Science Building – Replace AHU-11

Date: January 20, 2017 University of Missouri

Addendum 1 MU Project No. CP 161791

HUMIDIFIERS 238413 - 2

1.4 QUALITY ASSURANCE

A. Comply with AHRI 640 Commercial and Industrial Humidifiers.

1.5 COORDINATION

A. Coordinate physical size of humidifier steam dispersion manifold with interior dimensions of

the air handling unit for uniform steam distribution. At contractor’s discretion, ship steam

dispersion grids with complete written mounting instructions to air handling unit manufacturer’s

facility for incorporation into air handling units.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Deliver, store, and handle humidifiers according to manufacturer’s recommendations.

B. Store humidifiers on elevated platforms in a dry location.

1.7 WARRANTY

A. General Warranty: Extended warranty specified in this Article shall not deprive Owner of other

rights Owner may have under other provisions of the Contract Documents and shall be in

addition to, and run concurrent with, other warranties made by Contractor under requirements

of the Contract Documents.

B. Manufacturer’s Extended Warranty: Submit written warranty, signed by manufacturer, agreeing

to repair or replace any component up to and including the entire unit, due to defects in

materials or workmanship. Warranty must include parts, labor, shipping and handling charges,

and applicable taxes; for no out-of-pocket cost to the Owner. Extended warranty period shall be

manufacturer’s standard, but not less than two years (2) after date of Substantial Completion.

PART 2 - PRODUCTS

2.1 HUMIDIFIERS, GENERAL

A. Manufacturers: Subject to compliance with requirements, provide humidifiers and humidifier

accessory products by one of the following manufacturers:

1. Dri-Steem Humidifier Company.

2. Armstrong International, Inc.

3. Herrmidifier Co., Inc.

4. Nortec Industries Inc.

5. Pure Humidifier Company.

Page 13: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Medical Science Building – Replace AHU-11

Date: January 20, 2017 University of Missouri

Addendum 1 MU Project No. CP 161791

HUMIDIFIERS 238413 - 3

2.2 DIRECT STEAM-INJECTION HUMIDIFIERS

A. Steam Header / Separator: ASTM A666, Type 304 stainless steel, with integral heat exchanger

which shall provide atmospheric condensate vaporizing and pressurized condensate return.

1. All dispersion tube-generated condensate that falls to the heat exchanger in the header

shall be vaporized into humidification steam.

2. As condensate is vaporized in the header, pressurized condensate created in the heat

exchanger shall return to main without need for additional pumps, valves, or controls.

NOTE: Contractor’s Option to provide a humidifier which complies with this specification

except for the above described condensate management. In this case, Contractor shall consult

humidifier manufacturer regarding required vented condensate reservoir, and provide submittal

information for the condensate reservoir for Engineer’s review.

B. Humidifier Steam Control Valve: Comply with ANSI B16.15 Class 250; equal percentage flow

characteristics; brass or bronze body globe valve with stainless steel seat, stem and plug; sized

to meet humidification requirements.

1. Actuator: Electric modulating with spring return; normally closed.

2. Actuator: As specified in Division 23 Section “Control Systems.”

C. Heat Exchanger Control Valve: Two-position, normally closed, solenoid operated, on-off steam

valve. Valve shall respond to a signal from a humidistat via 24 VAC signal.

2.3 STEAM-INJECTION DISPERSION MANIFOLD

A. Steam Dispersion Grid: Tube bank consisting of a header and required quantity of multiple

dispersion tubes, factory assembled in a rack sized to fit across entire cross-section of duct or

plenum and equipped with mounting hardware.

1. Humidifier panel assembly shall be contained within a Type 304 stainless steel metal

casing to allow convenient mounting in air handler casings.

2. Header shall be constructed of ASTM A666, Type 304 or 316 stainless steel and shall be

fitted with 1-inch, 1½-inch or 2-inch tee outlets for dispersion tube connections. The

header shall be baffled or otherwise internally balanced to ensure uniform steam flow to

each dispersion tube.

3. The dispersion tubes shall be constructed of ASTM A666, Type 304 or 316 stainless steel

and shall be engineered to limit airstream sensible heat gain to a maximum of 3ºF when

no humidification is required.

4. Vapor emission ports shall be sized and located along the dispersion tube for uniform

steam distribution across the grid. Dispersion tubes shall either be fully jacketed with

punched emission ports, or unjacketed with emission port sleeves extending to the center

of the dispersion tube; to minimize condensate carryover.

5. Steam shall discharged in diametrically opposite directions, perpendicular to airflow, and

shall be absorbed into the airstream such that no moisture accumulates on interior air

handling unit surfaces more than 12 inches beyond the centerline of the steam dispersion

grid at 500 fpm face velocity. The dispersion tube quantity and spacing, and vapor outlet

ports quantity and spacing, shall be factory-engineered to meet this absorption

requirement.

Page 14: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Medical Science Building – Replace AHU-11

Date: January 20, 2017 University of Missouri

Addendum 1 MU Project No. CP 161791

HUMIDIFIERS 238413 - 4

6. Provide 1/8-inch thick, PVDF insulation on thermal dispersion tubes and humidifier grid

header. Insulation shall have a maximum rating under UL 723 (ASTM E84) flame

spread/smoke developed of 25/50; high temperature rated for 300ºF continuous

operation; closed-cell construction that will not absorb moisture and therefore not support

microbial growth; zero particle erosion per ASTM C1071, and resistant to UV light.

2.4 ACCESSORY HARDWARE

A. Steam Trap: Humidifier shall be provided with one float/thermostatic type trap complying with

Division 23 Section “Steam and Condensate Piping.”

B. Inlet Strainer: Humidifier shall be provided with one inlet strainer complying with Division 23

Section “Steam and Condensate Piping.”

2.5 FIELD PIPING

A. As specified in Division 23 Section “Steam and Condensate Piping.”

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine air-handling units for compliance with requirements for installation tolerances and

other conditions affecting performance.

B. Examine roughing-in for piping systems to verify actual locations of piping connections before

humidifier installation.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. Humidifier shall be factory installed within air handling unit by air handling unit manufacturer.

B. Install humidifiers as indicated, in accordance with manufacturer’s written instructions and

AHRI 640.

C. Install humidifiers with required clearance for service and maintenance.

D. Seal humidifier manifold duct or plenum penetrations with flange.

E. Install manifold supply piping pitched to drain condensate back to humidifier.

Page 15: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Medical Science Building – Replace AHU-11

Date: January 20, 2017 University of Missouri

Addendum 1 MU Project No. CP 161791

HUMIDIFIERS 238413 - 5

3.3 CONNECTIONS

A. Piping installation requirements are specified in other Division 23 Sections. Drawings indicate

general arrangement of piping, fittings, and specialties.

1. Install piping adjacent to humidifiers to allow service and maintenance.

3.4 FIELD QUALITY CONTROL

A. Perform tests and inspections and prepare test reports.

B. Tests and Inspections:

1. Leak Test: After installation, charge system and test for leaks. Repair leaks and retest

until no leaks exist.

2. Operational Test: After electrical circuitry has been energized, start units to confirm

proper motor rotation and unit operation.

3. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and

equipment.

C. Remove and replace malfunctioning units and retest as specified above.

3.5 DEMONSTRATION

A. Engage a factory-authorized service representative to train Owner’s maintenance personnel to

adjust, operate, and maintain humidifiers.

1. Train Owner’s maintenance personnel on procedures and schedules for starting and

stopping, troubleshooting, servicing, and maintaining equipment and schedules.

2. Review data in maintenance manuals. Refer to Division 01.

3. Schedule training with Owner, through Architect, with at least seven days’ advance

notice.

END OF SECTION 238413

Page 16: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

HOSPITAL DRIVE

MA

RY

LA

ND

AV

EN

UE

MA

RY

LA

ND

AV

EN

UE

DE

AN

S D

RIV

E

MEDICAL SCIENCE

FIELD

STANKOWSKI

CROWDER

LIBRARY

LOTTES

NURSING

MARYLAND AVENUEGARAGE

CRITICAL

CARE

MCHANEY

HALL

MA

SO

N E

YE

INS

TIT

UT

E

DIA

BE

TE

S

HOSPITAL

CONCOURSE

HOSPITAL & CLINICS

CLINICAL SUPPORT

& EDUCATION BLDG

MED SCIENCE

ADDITION

COOLINGTOWER

BIO-WASTE

MIS

SO

UR

I

PS

YC

HIA

TR

IC

CE

NT

ER

HAWTHORN

DOGWOOD

GA

LE

NA

STAGING PLANNO SCALE

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

4 P

M

505-106

X-1

DPP

STAGING PLAN

JCS

01/11/2017

DOUBLE DOOR ON THIS END OF THEFACILITY SHALL BE THE PRIMARYMEANS OF BRINGING EQUIPMENT ANDMATERIALS INTO MEDICAL SCIENCEBUILDING. THIS DOOR ENTERS INTOTHE HALLWAY ADJACENT TO THEFREIGHT ELEVATOR.

SERVICE DRIVE SHALL REMAINACCESSIBLE THROUGH ENTIREDURATION OF CONSTRUCTION

ACCESS DRIVE SHALL REMAINACCESSIBLE THROUGH ENTIREDURATION OF CONSTRUCTION

CONTRACTOR PARKING. TWO(2) SPACES WILL BE MADEAVAILABLE. COORDINATE WITHOWNER'S REPRESENTATIVE.

GRAVEL STAGING AREA AVAILABLE FOR ENTIRE DURATION OFCONSTRUCTION. CONTRACTOR SHALL INSTALL TEMPORARYPROTECTIVE FENCING AROUND ENTIRE STAGING AREA. FENCING SHALLBE LEFT IN PLACE THROUGHOUT DURATION OF CONSTRUCTION.CONTRACTOR SHALL TAKE CARE TO NOT DAMAGE OR DISRUPTEXISTING ELECTRICAL EQUIPMENT WITHIN THIS AREA.

SERVICE DRIVE

DE

AN

'S D

RIV

E

1

1 01/20/17 ADDENDUM 1

Page 17: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

M

EXISTING TO REMAIN

AHU

1

FLEXIBLE DUCT

PIPE SYSTEM ABBREVIATIONS

KEYED NOTE

SECTION NUMBER

SHEET WHERE LOCATED

INTERFACE, EXISTING TO NEW

CWS

CWR CHILLED WATER RETURN

CHILLED WATER SUPPLY

LPS

HWS

HWR

LPR LOW PRESSURE CONDENSATE RETURN

LOW PRESSURE STEAM SUPPLY

HEATING WATER SUPPLY

HEATING WATER RETURN

ROUND DUCT SIZE, (ACTUAL SIZE INDICATED)

ACCESS PANEL, TOP OR SIDE

TURNING VANES

CHANGE OF ELEVATION - RISE (R) OR DROP (D)

FLEXIBLE DUCT CONNECTION

UNIT NUMBER

EQUIPMENT DESIGNATION

SUPPLY AND OUTSIDE AIR SECTION UP

RETURN AIR SECTION UP

DRAIND

MOTORIZED DAMPER

MANUAL VOLUME DAMPER

FIRE DAMPER

TYPE OF SERVICE: S = SUPPLYR = RETURNE = EXHAUSTT = TRANSFER

AIR QUANTITY

IN CFM

SMOKE DAMPER

FIRE/SMOKE DAMPER

S-1

100

FLOW ARROW DOWNSTREAM OF FAN

FLOW ARROW UPSTREAM OF FAN

SCHEDULEDDEVICE NO

SPIRAL FLAT-OVAL DUCT SIZE, FIRST FIGUREIS SIDE SHOWN (ACTUAL SIZE INDICATED)

DEMO TO BE REMOVED

NEW WORK

UNIT NUMBER

DAMPER TYPE DESIGNATIONFSD

1

DUCT SIZE

12x12

12x12

12x12

12ø

12 x 10ø

R

AP

DUCT SIZE

DUCT SIZE, FIRST FIGURE IS SIDE SHOWN(CLEAR INSIDE, ADJUST FOR LINER)

PIPE LINE SYMBOLS

1

M101

SIM

M

SUPPLY AND OUTSIDE AIR SECTION DOWN

RETURN AIR SECTION DOWN

SHUT OFF VALVE (SEESPECIFICATION FOR TYPE)

BUTTERFLY VALVE

CHECK VALVE

CALIBRATED - ORIFACEBALANCING VALVE

IN-LINE PUMP

ELBOW DOWN

ELBOW UP

TEE DOWN

TEE UP

CAP

FLANGE

DEMO TO BE REMOVED

CONCENTRICREDUCER/INCREASER

ECCENTRICREDUCER/INCREASER

Y - PATTERN STRAINER

TWO-WAY CONTROL VALVE

MEDIUM DETAIL FINE DETAIL

MOTORIZED BUTTERFLYVALVE

UNION

AIR VENT (M - MANUAL,A - AUTOMATIC)

RELIEF VALVE

GENERAL NOTES:

TEMPERATURE SENSORT

PRESSURE ANDTEMPERATURE TEST PORT

EQUIPMENT DESIGNATION

GENERAL ABBREVIATIONS GENERAL ABBREVIATIONS, CONTINUED

#

BALL VALVE

M

DUCT SYSTEM SYMBOLS

GENERAL SYMBOLS

EXHAUST AIR SECTION UP

EXHAUST AIR SECTION DOWN

PLAN NUMBER

SHEET WHERE LOCATED

1

M101

PC PUMPED CONDENSATE

CONSTRUCTION PHASING NOTES:THE FIRST FLOOR INSTRUCTIONAL LAB AREA OF THE MEDICAL SCIENCESBUILDING WILL BE UNOCCUPIED BETWEEN MARCH 4, 2017 AND MARCH 12,2017. SCHEDULED OUTAGE OF HEATING HOT WATER AND CHILLED WATERSYSTEMS SHALL OCCUR DURING THIS TIME PERIOD. CONTRACTOR SHALLDEMOLISH ALL EXISTING FIRST FLOOR PIPING SHOWN TO BE REMOVED,INSTALL ALL NEW FIRST FLOOR HEATING HOT WATER PIPING, AND PROVIDEVALVED AND CAPPED CONNECTIONS FOR NEW VERTICAL HEATING HOTWATER AND CHILLED WATER RISERS. VERTICAL RISERS MAY BE INSTALLEDAT A LATER DATE. HEATING HOT WATER AND CHILLED WATER SYSTEMSSHALL BE FILLED, TESTED, AND MADE OPERATIONAL AGAIN BY THEFOLLOWING MONDAY MORNING (MARCH 13TH) TO RESTORE OPERATION OFTHE VARIOUS HVAC SYSTEMS WITHIN THE FACILITY AND ALLOW FORCOMPLETE AND NORMAL BUSINESS ACTIVITIES TO RESUME BY 6:00 AM ONTHAT SAME MONDAY MORNING (MARCH 13TH).

ALL EQUIPMENT SHUTDOWNS AND SCHEDULING OF WORK WITHINOCCUPIED SPACES SHALL BE COORDINATED WITH THE OWNER'SREPRESENTATIVE WITH A MINIMUM 2 WEEKS ADVANCE NOTICE.

SAW-CUTTING, CORE-DRILLING OF SLABS AND WALLS, USE OF HAMMERDRILLS, AND INSTALLATION OF POWDER-ACTUATED FASTENERS SHALLOCCUR ONLY DURING THE FOLLOWING TIME PERIODS TO MINIMIZEDISRUPTION OF ADJACENT WORK AND CLINICAL STUDY AREAS: 6:00 AM TO8:00 AM, OR 5:00 PM TO 10:00 PM.

PRIOR TO SHUTTING DOWN AHU-11, CONTRACTOR SHALL INSTALLTEMPORARY COOLING SYSTEMS FOR 5TH FLOOR LABS AND SUPPORT AREASAS SHOWN ON SHEET M001. CONTRACTOR SHALL COORDINATE WITHOWNER'S REPRESENTATIVE TO OBTAIN OWNER-FURNISHED WINDOW UNITS.CONTRACTOR SHALL PROVIDE AND INSTALL TEMPORARY ROLL-IN SPOTCOOLERS, WHERE REQUIRED.

SEE CONSTRUCTION PHASING PLAN ON M001 FOR SPECIFIC SCHEDULINGCONSTRAINTS ASSOCIATED WITH WORK ON THE FIFTH FLOOR.

1.

2.

3.

4.

5.

SUPPLY DIFFUSER AS SCHEDULED ARROWS INDICATEDIRECTION OF AIR DISCHARGE. IF NO ARROWS ARE SHOWNON PLAN, DEFAULT IS A 4-WAY THROW.

RETURN GRILLE OR REGISTER AS SCHEDULED

SIDEWALL DIFFUSER AS SCHEDULED

SIDEWALL RETURN OR EXHAUST AS SCHEDULED

EXHAUST GRILLE OR REGISTER AS SCHEDULED

ELEVATOR PROTECTION NOTES:THE INTEGRITY OF EXISTING FREIGHT ELEVATOR MUST BE MAINTAINEDDURING CONTRACTOR'S ACTIVITIES. THE FOLLOWING ELEVATORPROTECTION NOTES SHALL APPLY:

CONTRACTOR SHALL FULLY PROTECT THE INTERIOR OF THE ELEVATOR,INCLUDING BUT NOT LIMITED TO THE FLOOR, WALLS, CEILINGS, ANDELEVATOR CONTROLS.

ELEVATOR PROTECTION SHALL BE INSTALLED PRIOR TO THE START OFCONSTRUCTION AND SHALL REMAIN THROUGHOUT THE ENTIRE DURATIONOF CONSTRUCTION ACTIVITIES REQUIRING ELEVATOR USE.

1.

2.

FLOOR PROTECTION NOTES:THE INTEGRITY OF EXISTING FLOORING SURFACES THROUGHOUT THEFACILITY MUST BE MAINTAINED DURING CONTRACTOR'S ACTIVITIES. THEFOLLOWING FLOORING PROTECTION NOTES SHALL APPLY:

MOVEMENT OF MATERIAL AND EQUIPMENT INTO AND FROM THE FACILITYREQUIRES PROTECTION OF ALL FLOORING SURFACES THROUGHOUTTRAVEL PATH. CONTRACTOR SHALL UTILIZE PLASTIC PROTECTION SHEETSUNDER PLYWOOD OR MASONITE SHEETS OVER THE ENTIRE FLOORSURFACE TO PROTECT EXISTING TILE OR CARPETED FLOOR SURFACESFROM DAMAGE.

ANY EXISTING FLOORING SURFACES DAMAGED AS A RESULT OF THISCONSTRUCTION WORK SHALL BE REPAIRED BY CONTRACTOR TO THESATISFACTION FO THE OWNER'S REPRESENTATIVE.

1.

2.

1

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

3 P

M

505-106

M000

DPP

MECHANICAL SYMBOLS,ABBREVIATIONS, AND

GENERAL ANDCONSTRUCTION PHASING

NOTES

JCS

01/11/2017

ACU AIR CONDITIONING UNIT

AF AIR FILTER

AHU AIR HANDLING UNIT

BCU BLOWER COIL UNIT

CAV CONSTANT AIR VOLUME

CC COOLING COIL

CU CONDENSING UNIT

EAV EXHAUST AIR VALVE

EF EXHAUST FAN

F FAN

FAV FUME AIR VALVE

FCU FAN COIL UNIT

FD FIRE DAMPER

FSD COMBINATION FIRE/SMOKE DAMPER

H HUMIDIFIER

HC HEATING COIL

HEV HOOD EXHAUST VALVE

HPU HEAT PUMP UNIT

HWP HEATING WATER PUMP

L LOUVER

MD MOTORIZED DAMPER

P PUMP

PICV PRESSURE INDEPENDENT CONTROL VALVE

RHC TERMINAL REHEAT COIL

RTU ROOFTOP UNIT

SAV SUPPLY AIR VALVE

SD SMOKE DAMPER

SF SUPPLY FAN

ST STEAM TRAP

UH UNIT HEATER

VAV VARIABLE AIR VOLUME BOX

MANU MANUFACTURER

MAX MAXIMUM

MBH THOUSAND BRITISH THERMAL UNITS PER HOUR

MCC MOTOR CONTROL CENTER

MECH MECHANICAL

MERV MINIMUM EFFICIENCY REPORTING VALUE (ASHRAE 52.2)

MFR MANUFACTURER

MIN MINIMUM OR MINUTE (PER CONTEXT)

MTD MOUNTED

MTL METAL

MV MANUAL VENT

NC NORMALLY CLOSED OR NOISE CRITERIA (PER CONTEXT)

NIC NOT IN CONTRACT

NO NORMALLY OPEN OR NUMBER (PER CONTEXT)

NOM NOMINAL

NPLV NON-STANDARD PART LOAD VALUE

NPSH NET POSITIVE SUCTION HEAD

NTS NOT TO SCALE

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

OC ON CENTER

OD OUTSIDE DIAMETER

OT OIL TRAP

PA PIPE ANCHOR

PBD PARALLEL BLADE DAMPER

PD PRESSURE DROP

PENT PENTHOUSE

PH PHASE

PHC PREHEAT COIL

PLBG PLUMBING

PNEU PNEUMATIC

PPH POUNDS PER HOUR

PRESS PRESSURE

PRV PRESSURE REGULATING VALVE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH ABSOLUTE

PSIG POUNDS PER SQUARE INCH GAUGE

QTY QUANTITY

RA RETURN AIR

REFR REFRIGERANT

REQ REQUIRED

RH RELATIVE HUMIDITY

RM ROOM

RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR

SAN SANITARY

SEC'N SECTION

SEER SEASONAL ENERGY EFFICIENCY RATIO

SENS SENSIBLE

SF SQUARE FOOT

SH SENSIBLE HEAT

SHT SHEET

SND SOUND

SOL SOLENOID

SP STATIC PRESSURE

SPD STATIC PRESSURE DIFFERENTIAL

SPT STATIC PRESSURE TRANSMITTER

SQ SQUARE

SST STAINLESS STEEL

STL STEEL

STM STEAM

T&P TEMPERATURE AND PRESSURE

TC TEMPERATURE CONTROL

TD THERMODYNAMIC OR TEMPERATURE DIFFERENTIAL (PER CONTEXT)

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

TOT TOTAL

TSP TOTAL STATIC PRESSURE

TYP TYPICAL

UC UNDERCUT DOOR

UNO UNLESS NOTED OTHERWISE

V VOLTS

VAC VACUUM

VD VOLUME DAMPER (MANUAL)

VEL VELOCITY

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

VTR VENT THRU ROOF

W WATT OR WIDTH (PER CONTEXT)

W/ WITH

W/O WITHOUT

WB WET BULB

WC WATER COLUMN

WG WATER GAUGE

WPD WATER PRESSURE DIFFERENTIAL

WT WEIGHT

A AIR OR AMP (PER CONTEXT)

ACC ACCESSORIES

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AFS AIR FLOW SWITCH

AI ANALOG SIGNAL INPUT

AMB AMBIENT

AO ANALOG SIGNAL OUTPUT

AP ACCESS PANEL

APD AIR PRESSURE DROP

APPROX APPROXIMATE

ARCH ARCHITECTURE/ARCHITECT

AUX AUXILIARY

AV AUTOMATIC VENT

AVG AVERAGE

BDD BACK DRAFT DAMPER

BFC BELOW FINISHED CEILING

BFP BACKFLOW PREVENTER

BHP BRAKE HORSEPOWER

BI BINARY SIGNAL INPUT

BMS BUILDING MANAGEMENT SYSTEM

BO BINARY SIGNAL OUTPUT

BOB BOTTOM OF BEAM

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BS BEAM SPACE

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNITS PER HOUR

CAP CAPACITY

CAV CONSTANT AIR VOLUME

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CI CAST IRON

CLG COOLING DUCT (COLD DUCT)

CO CLEAN OUT

CONC CONCRETE

COND CONDENSATE

CONN CONNECTION

CORR CORRIDOR

CV CONTROL VALVE

D DEPTH

DB DRY BULB

DBA A-WEIGHTED DECIBELS

DEFL DEFLECTION

DEG DEGREES

DEG F DEGREES FAHRENHEIT

DES DESIGN

DIA DIAMETER

DIM DIMENSION

DISCH DISCHARGE

DIV DIVISION

DN DOWN

DP DIFFERENTIAL PRESSURE SENSOR

DPS DIFFERENTIAL PRESSURE SWITCH

DPT DIFFERENTIAL PRESSURE TRANSMITTER

DTL DETAIL

DWG(S) DRAWING(S)

EA EXHAUST AIR OR EACH (PER CONTEXT)

EAT ENTERING AIR TEMPERATURE

EFF EFFICIENCY

ELEC ELECTRIC

ELEV ELEVATION

EQ EQUAL

ESP EXTERNAL STATIC PRESSURE

EWB ENTERING AIR WET BULB TEMPERATURE

EWT ENTERING WATER TEMPERATURE

EXH EXHAUST

EXIST, EX EXISTING

EXT EXTERNAL

F FAHRENHEIT

FC FLEXIBLE CONNECTION

FD FLOOR DRAIN

FIN FINISHED

FLR FLOOR

FPF FINS PER FOOT

FPM FEET PER MINUTE

FT FEET

FT-HD HEAD IN FEET

GA GAUGE

GAL GALLONS

GALV GALVANIZED

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

H HEIGHT

HD HEAD

HEV HOSE END VALVE

HORIZ HORIZONTAL

HP HORSEPOWER

HR HOUR

HTG HEATING DUCT (HOT DECK)

HVAC HEATING, VENTILATING & AIR CONDITIONING

HW HOT WATER

HZ HERTZ

IN INCH/INCHES

INDIC INDICATOR

ISP INTERNAL STATIC PRESSURE

JS JOIST SPACE

KW KILOWATTS

L LENGTH

LAT LEAVING AIR TEMPERATURE

LB(S) POUNDS

LF LINEAR FEET

LVL LEVEL

LWT LEAVING WATER TEMPERATURE

MAN MANUAL

THESE PLANS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR SHALL BE PREPARED TO MAKE SOME ALTERATIONS TO THE EXACTLOCATION OF DUCTWORK, PIPING AND EQUIPMENT FROM THE LOCATION INDICATED ON THESE DRAWINGS TO FIT ACTUAL JOBCONDITIONS.

ALL ELBOWS, FITTINGS, ETC., IN PIPING AND DUCTWORK REQUIRED TO CLEAR ALL JOB OBSTRUCTIONS ARE NOTNECESSARILY INDICATED. ALL NECESSARY TRANSITIONS, FITTINGS AND OFFSETS ARE REQUIRED WHETHER SHOWN OR NOT.

BECAUSE OF THE LIMITED SPACE AVAILABLE TO INSTALL ALL OF THE MECHANICAL WORK, COORDINATION BETWEENTHE VARIOUS TRADES IS OF THE UTMOST IMPORTANCE.

THE CONTRACTOR SHALL COORDINATE STAGING AND SCHEDULING WITH THE OWNER'S REPRESENTATIVE.

EXISTING CONDITIONS ARE BASED ON INFORMATION OBTAINED FROM PREVIOUS CONSTRUCTION DOCUMENTS AND INFORMAL FIELDOBSERVATION AND SHALL NOT BE CONSTITUTED AS "AS BUILT." THE CONTRACTOR SHALL FIELD-VERIFY EXISTING CONDITIONSBEFORE THE ONSET OF CONSTRUCTION.

DEMOLISH ALL PIPING, DUCTWORK EQUIPMENT, ETC., SHOWN TO BE REMOVED, IN ITS ENTIRETY,INCLUDING ALL HANGERS ANDSUPPORTS.

WHERE CONTRACTOR IS REQUIRED TO CONCEAL NEW WORK, REMOVE OR MODIFY EXISTING CONSTRUCTION OR EQUIPMENT, ORATTACH TO EXISTING CONSTRUCTION, THE CONTRACTOR SHALL REPAIR OR REPLACE EXISTING CONSTRUCTION AND MATERIALS TOMATCH CONDITIONS AT THE ONSET OF CONSTRUCTION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REMOVE AND REPLACE EXISTINGCEILINGS AND WALLS REQUIRED FOR INSTALLATION OF MECHANICAL SYSTEMS.

THE OWNER SHALL MAINTAIN ALL SALVAGE RIGHTS OF EQUIPMENT AND MATERIALS REMOVED. ALL EQUIPMENT AND MATERIALS NOTCLAIMED BY THE OWNER SHALL BE REMOVED FROM THE PREMISES BY THIS CONTRACTOR.

ALL EXISTING DDC CONTROLS LOCATED IN THE 5TH FLOOR MECHANICAL ROOM SHALL BE REMOVED BY ONLY THE OWNER.

ALL WORK SHALL BE INSTALLED PER THE REFERENCE DETAILS, REGARDLESS OF WHETHER OR NOT THE DETAILS ARE CALLED OUT ONTHE PLANS. SEE 500 SERIES SHEET(S).

PROVIDE VENTS AT ALL HYDRONIC PIPING HIGH POINTS, AND DRAINS AT ALL PIPING LOW POINTS, REGARDLESS OF WHETHER SHOWN ORNOT.

DUE TO EXTENSIVE OCCURRENCE OF HAZARDOUS MATERIALS USED IN THE ORIGINAL CONSTRUCTION OF THE BUILDING (I.E. LEAD-BASEDPAINT, ASBESTOS INSULATION, AND TRANSITE EXHAUST DUCTWORK), THE CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH THEABATEMENT CONTRACTOR. EFFORTS HAVE BEEN MADE TO SHOW THE MAJORITY OF THIS DEMOLITION ON THE PLANS, BUT CLEARLY, THEEXACT LOCATION AND EXTENT OF THIS DEMOLITION MUST BE FULLY COORDINATED. NOTE: FOR ALL INSTANCES WHERE EXISTINGHAZARDOUS MATERIALS WERE REMOVED FROM EXISTING PIPING SYSTEMS WHICH WILL REMAIN IN PLACE FOLLOWING THIS PROJECT,CONTRACTOR SHALL INSTALL NEW INSULATION ON EXISTING EXPOSED PIPING MEETING INSULATION SPECIFICATIONS. DO NOT LEAVEANY EXISTING PIPING UNINSULATED.

ALL DUCTWORK SHALL COMPLY WITH "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," SMACNA LATEST EDITION,EXCEPT WHERE MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED. ANY PLAN REFERENCES TO "SMACNA FIGURE ---" REFERS TO THISSTANDARD. SEE SPECIFICATIONS FOR SCHEDULE OF DUCT PRESSURE CLASS AND SEAL CLASS.

IT IS THE INTENT OF THESE DRAWINGS THAT A MANUAL BALANCING DAMPER BE PROVIDED AT EVERY INDIVIDUAL DUCTED CONNECTIONTO AN AIR DEVICE. NOTE, UNLESS A BALANCING DAMPER IS SCHEDULED TO BE FURNISHED WITH AIR DEVICE. PROVIDE A MANUALBALANCING DAMPER IN EACH INDIVIDUAL BRANCH DUCT SERVING AN AIR DEVICE BETWEEN THE CONNECTION TO THE DUCT SERVINGMULTIPLE DEVICES AND THE AIR DEVICE WHEN HARD DUCTED AND AT EACH POINT OF CONNECTION OF FLEX DUCT RUNOUT TO BRANCHDUCT (AT THE SPIN-IN FITTING) WHERE FLEX DUCT IS USED.VAV BOXES WITH SINGLE DIFFUSERS ARE NOT REQUIRED TO HAVE ABALANCING DAMPER.

COORDINATE WITH OWNER'S REPRESENTATIVE TO VERIFY ALL EXISTING OWNER SALVAGED AND OWNER REMOVED CONTROLS WORK ISCOMPLETE. ALL EXISTING TEMPERATURE CONTROLS THAT ARE BEING DEMOLISHED OR DISABLED AS WORK OF THIS CONTRACT SHALLBE COMPLETELY REMOVED FROM THIS PROJECT WORK AREA. REMOVE ALL EXISTING CONTROL WIRING, PNEUMATIC TUBING ANDRELATED CONTROLS AND ALL ACCESSORIES MADE OBSOLETE BY THE WORK OF THIS PROJECT. PROVIDE A BRASS COMPRESSION CAPTYPE FITTING AT ALL UNUSED TERMINATIONS. DO NOT PINCH-OFF TUBING.

THE CONTRACTOR SHALL CONNECT THE NEW HVAC CONTROL SYSTEM TO THE OWNER'S EXISTING BUILDING CONTROL SYSTEM. REFER TOTHE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

THE WORK OF SECTION 230900 SHALL INCLUDE THE FOLLOWING ELECTRICAL WORK, COMPLYING WITH REQUIREMENTS OF DIVISION26 SECTIONS:

A. CONTROL WIRING BETWEEN FIELD-INSTALLED CONTROLS, INDICATING DEVICES, AND UNIT CONTROL PANELS.

B. INTERLOCK WIRING BETWEEN ELECTRONICALLY OPERATED EQUIPMENT UNITS AND BETWEEN EQUIPMENT AND FIELD INSTALLEDCONTROL DEVICES.

C. POWER SUPPLY WIRING FROM POWER SOURCES TO POWER CONNECTION ON CONTROLS AND/OR UNIT CONTROL PANELS,INCLUDING, BUT NOT LIMITED TO, AIR TERMINAL UNIT CONTROLLERS, DDC PANELS, DAMPER ACTUATORS, AND VALVE ACTUATORS.

IT SHOULD BE NOTED THAT EXHAUST SYSTEMS MAY BE REQUIRED TO BE BALANCED MORE THAN ONCE TO ASSURE DESIGNAIRFLOWS ARE PROVIDED.

THE SCOPE OF WORK FOR THIS PROJECT IS LOCATED ON FLOORS 1 THROUGH 5 OF THE MEDICAL SCIENCE BUILDING. IT ISSTRONGLY ENCOURAGED THAT THE CONTRACTOR VISITS THE SITE PRIOR TO SUBMITTING HIS OR HER BIDS. CONTRACTOR SHALLINCLUDE IN HIS OR HER BID ALL COSTS TO DISASSEMBLE AND REASSEMBLE NEW EQUIPMENT IN ORDER TO MOVE IT INTO PLACE.COSTS SHALL INCLUDE MANUFACTURER SUPERVISION THAT IS REQUIRED TO MAINTAIN EQUIPMENT WARRANTIES IN FULL. EQUIPMENTIS NOT ALLOWED TO BE CUT TO BE BROUGHT INTO PLACE. CONTRACTOR SHALL PROTECT STAIR AND SERVICE ELEVATOR TO NOTDAMAGE DURING CONSTRUCTION. ALL DAMAGE SHALL BE AT THE COST OF THE CONTRACTOR TO REPAIR TO MATCH EXISTINGCONDITIONS. ACCESS TO THE JOB SITE IS THROUGH THE EXISTING BUILDING (EXISTING STAIRS AND SERVICE ELEVATOR). ALLEQUIPMENT AND MATERIALS SHALL BE BROUGHT TO THE WORK AREA THROUGH THESE MEANS ONLY. CONTRACTOR SHALL FIELDVERIFY SERVICE ACCESS. THE EXISTING SERVICE ELEVATOR HAS LIMITED ACCESS OF 83 INCHES TALL BY 84 INCHES DEEP BY 43

INCHES WIDE. CONTRACTOR SHALL PROTECT INTEGRITY OF ELEVATOR PER ELEVATOR PROTECTION NOTES ON THIS SHEET.

COORDINATE DRAINING AND FILLING OF CHILLED WATER SYSTEM WITH OWNER'S REPRESENTATIVE.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO VENT AIR FROM ALL COILS AFFECTED BY WORK OF THIS PROJECT. REFER TO M401FOR MORE INFORMATION AND CONSULT OWNER'S REPRESENTATIVE TO HELP ENSURE COILS ARE NOT MISSED.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

1 01/20/17 ADDENDUM 1

Page 18: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

ROOF

SCHOOL OF NURSING

3. SPOT COOLER SHALL REMAIN IN SERVICE UNTIL NEW AHU-11 IS MAHE OPERATIONAL.

2. SPOT COOLER SHALL BE COMPATIBLE WITH STANDARD NEMA 5-15 PLUG.

1. CONTRACTOR SHALL PROVIDE SCHEDULED MAKE/MODEL OR APPROVED EQUAL. PROVIDE SPOT COOLER WITH FACTORY HOSES AND CONDENSATE PUMP

NOTES:

PLAN MARK MFR. MODEL SERVICE LOCATION

AIRFLOW(CFM) NOTES

SC 1 SPOT COOLER OFFICE PRO 12 M529 410 1, 2, 3

2

3

4

5

SC

SC

SC

SC

SPOT COOLER

SPOT COOLER

SPOT COOLER

SPOT COOLER

OFFICE PRO 12

OFFICE PRO 12

OFFICE PRO 12

OFFICE PRO 12

M528

M526

M531

M533

M529

M528

M526

M531

M533

410

410

410

410

TOTAL COOLINGCAPACITY (MBH)

12.0

12.0

12.0

12.0

12.0

V/PH/HZ

120 / 1 /60

120 / 1 /60

120 / 1 /60

120 / 1 /60

120 / 1 /60

ELECTRICAL DATA

1, 2, 3

1, 2, 3

1, 2, 3

1, 2, 3

TEMPORARY SPOT COOLER SCHEDULE

RESEARCHLABORATORY

M531

RESEARCHOFFICE

M533

RESEARCHOFFICE

M530

RESEARCHOFFICE

M526

COOLER

M525

RESEARCHLABORATORY

M529

MEN'SREST.

M536

WOMEN'SREST.

M535

CORRIDOR

M517

RESEARCHLABORATORY

M523

RESEARCHLABORATORY

M522

MECHANICALROOM

M524

TISSUECULTURE

M521

CELLCULTURE

M519A

RESEARCHOFFICE

M520

RESEARCHLABORATORY

M519

RESEARCHLABORATORY

M518

MICROSCOPELAB

M518B

MICROSCOPELAB

M518C

OFFICE

M517C

M516A

RESEARCHLABORATORY

M514

RESEARCHLABORATORY

M512

RESEARCHOFFICE

M512A

M511

RESEARCHLABORATORY

M509

LABSERV

M508

RESEARCHLABORATORY

M506M505

RESEARCHOFFICE

M503A

RESEARCHLABORATORY

M504

RESEARCHLABORATORY

M503

RESEARCHLABORATORY

M538

RESEARCHLABORATORY

M537

MICROSCOPELAB

M518A

OFFICE

M516B

OFFICE

M516C

OFFICE

M516D

OFFICE

M516E

OFFICE

M516F

OFFICE

M516

OFFICESERVICE

OFFICE

RESEARCHOFFICE

RESEARCHLAB

M528

1

3

2 2 2 2 2 2 2 2 2 2 2 2 2 2

222222222

1

1

SC

4

SC

5

SC

1

SC

2

SC

3

4

6

6

7

7

8

5

5

1

1

9

5

5

10

11

11

12

12

1

2

3

CONTRACTOR SHALL REFER TO CONSTRUCTIONPHASING NOTES ON SHEET M000 FOR INFORMATIONREGARDING REQUIREMENTS AND RESTRICTIONS ONANY CONSTRUCTION ACTIVITIES IMPACTING BUILDINGOPERATIONS AND SYSTEMS.

CONTRACTOR SHALL INSTALL TEMPORARY FRAMEDPLASTIC CONSTRUCTION BARRIER(S) TO CONTAINDUST AND DEBRIS ASSOCIATED WITHCONSTRUCTION ACTIVITIES. BARRIER(S) SHALL BEDESIGNED TO MAINTAIN ACCESS TO REGULARLYOCCUPIED SPACES. BARRIER(S) SHALL BECONSTRUCTED PRIOR TO DEMOLITION AND SHALLREMAIN IN PLACE UNTIL CONSTRUCTION ISCOMPLETE. INSTALL STICKY MATS PADS IN FRONTOF ALL TEMPORARY DOORS ASSOCIATED WITHCONSTRUCTION BARRIER(S). REFER TO DIVISON 1SPECIAL CONDITIONS FOR MORE INFORMATION.

FOR ALL WORK IN OCCUPIED LAB AND OFFICESPACES, CONTRACTOR SHALL COMPLETELY COVERALL BENCHTOPS, SHELVING, CABINETS, FURNITURE,AND EQUIPMENT WITH PROTECTIVE PLASTICSHEETING TO PREVENT DAMAGE. TEMPORARYPROTECTIVE COVERING SHALL REMAIN IN PLACEPRIOR TO DEMOLITION THROUGH COMPLETION OFWORK WITHIN THE SPACE. UPON COMPLETION OFWORK, CONTRACTOR SHALL WIPE DOWNCOUNTERS, TABLES, AND FURNITURE, AND VACUUMAS NECESSARY TO RETURN SPACE TO ORIGINALCONDITION PRIOR TO CONSTRUCTION.

GENERAL NOTES:

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

3 P

M

505-106

M001

DPP

FIFTH FLOOR TEMPORARYCOOLING AND

CONSTRUCTION PHASINGPLAN

JCS

01/11/2017

1/8" = 1'-0"1

FIFTH FLOOR TEMPORARY COOLING ANDCONSTRUCTION PHASING PLAN

KEYED NOTES:

1 CONTRACTOR SHALL PROVIDE TEMPORARY SPOTCOOLER TO SERVE SPACE. CONTRACTOR TOTEMPORARILY ROUTE PUMPED CONDENSATE LINE TONEARBY SINK OR FLOOR DRAIN. DRAIN LINE SHALL BEROUTED IN A MANNER TO AVOID CREATING A TRIPHAZARD FOR BUILDING OCCUPANTS. ROUTE SPOTCOOLER HOT VENT HOSE TO NEAREST RA DUCT.PATCH RA DUCT AIRTIGHT ONCE SPOT COOLER ISREMOVED FROM SERVICE.

2 OWNER-FURNISHED WINDOW AC UNIT. CONTRACTORSHALL COORDINATE WITH OWNER'S REPRESENTATIVETO OBTAIN WINDOW UNITS SALVAGED FROM THELATHROP AND LAWS DEMOLITION PROJECT TOPROVIDE TEMPORARY COOLING FOR SPACES SERVEDBY AHU-11. CONTRACTOR SHALL PROVIDE ANDINSTALL PLYWOOD PANELS TO SUPPORT WINDOWUNIT AND BLANK-OFF REMAINING WINDOW OPENINGFOLLOWING UNIT INSTALLATION. WINDOW UNITSSHALL REMAIN IN SERVICE UNTIL NEW AHU-11 IS MADEOPERATION. WINDOW UNITS SHALL BE RETURNED TOOWNER'S REPRESENTATIVE IN GOOD WORKINGORDER. FOLLOWING REMOVAL OF WINDOW UNIT,CONTRACTOR SHALL PATCH / PAINT WINDOW FRAMINGAND SURROUNDING SURFACES TO REPAIR ANYDAMAGE CAUSED BY INSTALLATION OF UNIT ANDSURROUNDING PLYWOOD SUPPORT.

3 CONTRACTOR SHALL INSTALL A TEMPORARYWALL-MOUNTED PROPELLER EXHAUST FAN ONEXISTING LOUVER TO EXHAUST AND NEGATIVELYPRESSURIZE THE CONSTRUCTION AREA.CONTRACTOR SHALL CONSTRUCT TEMPORARYCONSTRUCTION ZONE PARTITIONS TO PREVENTMITIGATION OF DUST TO THE ADJACENT OCCUPIEDSPACES. EXHAUST FAN SHALL EXHAUST MINIMUM 500CFM. FAN SHALL REMAIN OPERATIONAL UNTIL AHU-11IS MADE OPERATIONAL.

4 EXISTING OPENING IN CMU WALL BETWEENMECHANICAL ROOM AND CORRIDOR PUT IN PLACE ASWORK OF A PRIOR PROJECT. INSTALLATION OF DOORIS PENDING. AT THE DISCRETION OF THECONTRACTOR, THE EXISTING CMU WALL MAY BEREMOVED AS NECESSARY TO FACILITATE THE WORK.WALL MUST BE REPLACED TO MATCH EXISTING IFREMOVED.

5 ALL WORK WITHIN THIS HATCHED REGION CONSISTINGOF NORTH HALF OF CORRIDOR, OFFICE M526, AND LABM528 SHALL BE COMPLETED IN A 1 WEEK WINDOW,START TO FINISH.

6 ALL WORK WITHIN THIS HATCHED REGION CONSISTINGOF LAB M529 AND OFFICE M530 SHALL BE COMPLETEDIN A 1 WEEK WINDOW, START TO FINISH. SOUTH HALFOF LAB SHALL REMAIN OPERATIONAL THROUGHOUTENTIRE DURATION OF WORK IN THIS AREA.

7 ALL WORK WITHIN THIS HATCHED REGION CONSISTINGOF LAB M531 AND OFFICE M533 SHALL BE COMPLETEDIN A 2 WEEK WINDOW, START TO FINISH. NORTH HALFOF LAB SHALL REMAIN OPERATIONAL THROUGHOUTENTIRE DURATION OF WORK IN THIS AREA.

8 A FULL HEIGHT DUST PARTITION SHALL BE INSTALLEDHERE TO SEPARATE THIS LAB INTO TWO SEPARATEZONES TO ALLOW FOR PHASED CONSTRUCTION.

9 A FULL HEIGHT DUST PARTITION WITH ACCESS DOORSHALL BE INSTALLED HERE TO SEPARATE THECORRIDOR INTO TWO SEPARATE ZONES TO ALLOWFOR PHASED CONSTRUCTION.

10 ALL WORK WITHIN LAB M521 SHALL BE COMPLETED INA 1 WEEK WINDOW, START TO FINISH.

11 ALL WORK WITHIN THIS HATCHED REGION CONSISTINGOF SOUTH HALF OF CORRIDOR SHALL BE COMPLETEDIN A 1 WEEK WINDOW, AFTER COMPLETION OFCONSTRUCTION IN NORTH HALF OF CORRIDOR.

12 AFTER COMPLETION OF WORK IN SOUTH CORRIDOR,CONTRACTOR SHALL PROVIDE A TEMPORARY FULLHEIGHT DUST PARTITION (SIZED APPROXIMATELY ASSHOWN BY HATCHED REGION) WITH ACCESS DOOR TOPROTECT OCCUPIED SPACES FROM CONSTRUCTIONDUST AND DEBRIS WHILE STILL ALLOWING LABOCCUPANTS TO ENTER LAB M531 AND OFFICE M533.

#

NORTH

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

1

1

1

1 01/20/17 ADDENDUM 1

Page 19: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

DN

LOCKERS LOCKERSLOCKERS LOCKERS

LOCKERS

LOCKERS

LOCKERS

LOCKERS

LOCKERS LOCKERS

LOCKERS

526

527

EXTERIOR STAIR

(STAIRWAY TAKENOUT OF SERVICE)

CW

R

CW

S

HWRHWS

LPSLPSLPS

EX 6"HWSEX 6"HWR

LP

S

2 1/2" HWS2 1/2"HWR

6" CWS6" CWR

2 1

/2"H

WR

2 1

/2"H

WS

6" CWS6" CWR

6" CWS6" CWR

6" CWS

6" CWR

ABANDONEDPIPING

EXISTING LPSTO REMAIN

EXISTING LPSTO REMAIN

EX 2 1/2"HWSEX 2 1/2"HWREX 4" CWSEX 4" CWR

2 1/2" HWS2 1/2" HWR

6" CWS

6" CWR

INSTRUCTIONAL LABGROSS ANATOMY

M148

LAB ENTRY

M144

UNEMBALMEDLAB

M144C6" HWSUP/DOWN6" HWRUP/DOWN

12" CWSUP/DOWN12" CWRUP/DOWN

10" HWSFROMBELOW

EMBALMEDLAB

M144B

INSTRUCTIONALLAB

M134

INSTRUCTIONALLAB

M133

INSTRUCTIONALLAB

M132

INSTRUCTIONALLAB

M131

INSTRUCTIONALLAB

M126

STORAGE

M125A

STORAGE

M125B

STORAGE

M125

ELECSTO

MY100A

6" HWR6" HWS

2

1

1

1

2

2

2

2

2

2

2

2

1

2

EXISTING CWS/CWRTO REMAIN

EXISTING CWS/CWRTO REMAIN

EXISTING CWS/CWRTO REMAIN

3

CORR

M145

2

DRESSROOM

M144A

CHEMSTOR

M144B-1

CAP

CAP

EXISTINGABANDONEDDUCTS

4

10" HWRDN

8"x12"

30"x12"

3

3

3

5

66

7 7

7 7

8 8

88

78

1

1.

2.

3.

SEE M000 FOR GENERAL NOTES.

ALL PIPING SHOWN DASHED SHALL BECOMPLETELY REMOVED ALONG WITH ALLASSOCIATED HANGERS AND SUPPORTS.

CONTRACTOR SHALL REFER TO CONSTRUCTIONPHASING NOTES ON SHEET M000 FORINFORMATION REGARDING REQUIREMENTS ANDRESTRICTIONS ON ANY CONSTRUCTION ACTIVITIESIMPACTING BUILDING OPERATIONS AND SYSTEMS

GENERAL NOTES:

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

1 P

M

505-106

MD101

DPP

FIRST FLOOR DEMOLITIONPLAN

JCS

01/11/2017

NORTH

1/8" = 1'-0"1

FIRST FLOOR DEMOLITION PLAN

KEYED NOTES:

1 NO CEILING EXISTS IN THIS SPACE.

2 REMOVE AND REINSTALL EXISTING ACOUSTICALCEILING TILES AND GRID IN THIS ROOM TO ALLOWFOR DEMOLITION OF EXISTING PIPING. STORETILES IN SAFE PLACE, FREE OF OBSTRUCTION TOMINIMIZE DAMAGE. REPLACE ANY DAMAGED GRIDAND CEILING TILES TO THE SATISFACTION OF THEOWNER.

3 DEMO EXISTING HEATING HOT WATER PIPING BACKTO EXISTING 10-INCH SHUTOFF VALVES, ALONGWITH ALL ASSOCIATED HANGERS AND SUPPORTS.

4 DEMOLISH SECTION OF EXISTING ABANDONEDDUCTWORK BACK TO NEAREST JOINT TO PROVIDECLEAR PATH FOR NEW HEATING HOT WATERRISERS. CAP OPEN ENDS OF DUCTS AIRTIGHTFOLLOWING DEMOLITION.

5 REMOVE SECTION OF CHILLED WATER PIPING.ALONG WITH EXISTING SHUTOFF VALVES.

6 EXISTING CHILLED WATER SHUTOFF VALVES ACTAS THE PRIMARY MEANS OF SHUTTING OFF THECHILLED WATER SYSTEM. COORDINATE ALLSYSTEM SHUTDOWNS WITH OWNER'SREPRESENTATIVE. SEE M000 FOR MOREINFORMATION.

7 WORK WITHIN THIS BOUNDARY SHALL BEPERFORMED ONLY WHEN MEDICAL SCIENCESBUILDING IS SCHEDULED TO BE UNOCCUPIEDBETWEEN MARCH 4, 2017 AND MARCH 12, 2017.REFER TO CONSTRUCTION PHASING NOTE #1 ONM000 FOR MORE INFORMATION.

8 FOR ALL SPACES WITHIN THIS BOUNDARY, PRIORTO DEMOLITION CONTRACTOR SHALLCOMPLETELY COVER ALL FURNITURE,COUNTERTOPS, BENCES, AND EQUIPMENT WITHPROTECTIVE PLASTIC SHEETING TO PREVENTDAMAGE. TEMPORARY PROTECTIVE COVERINGSHALL REMAIN IN PLACE UNTIL COMPLETION OFWORK IN THIS AREA. UPON COMPLETION OF WORK,CONTRACTOR SHALL WIPE DOWN COUNTERS,TABLES, AND FURNITURE, AND VACUUM ASNECESSARY TO RETURN SPACE TO ORIGINALCONDITION PRIOR TO CONSTRUCTION.

#

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

1

1 01/20/17 ADDENDUM 1

Page 20: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

UP

1

MD103

58"x10"COLD

(BOTTOM)

58"x9"HOT

(TOP)

30"x9" HOT (TOP)30"x10" COLD(BOTTOM)

RESEARCHLABORATORY

M531

RESEARCHOFFICE

M533

RESEARCHOFFICE

M530

RESEARCHOFFICE

M526

COOLER

M525

RESEARCHLABORATORY

M529

MEN'SREST.

M536

WOMEN'SREST.

M535

CORRIDOR

M517

RESEARCHLABORATORY

M523

RESEARCHLABORATORY

M522

MECHANICALROOM

M524

38"x7" COLD(BOTTOM)

38"x6" HOT(TOP)

(BOTTOM)(TOP) (BOTTOM)(TOP) (BOTTOM)(TOP) (BOTTOM)(TOP)

TISSUECULTURE

M521

CELLCULTURE

M519A

RESEARCHOFFICE

M520

RESEARCHLABORATORY

M519

RESEARCHLABORATORY

M518

MICROSCOPELAB

M518B

MICROSCOPELAB

M518C

OFFICE

M517C

M516ARESEARCH

LABORATORY

M514

RESEARCHLABORATORY

M512

RESEARCHOFFICE

M512A

M511

RESEARCHLABORATORY

M509LABSERV

M508

RESEARCHLABORATORY

M506M505RESEARCHOFFICE

M503A

RESEARCHLABORATORY

M504

RESEARCHLABORATORY

M503

RESEARCHLABORATORY

M538 RESEARCHLABORATORY

M537

MICROSCOPELAB

M518A

OFFICE

M516B

OFFICE

M516C

OFFICEM516D

OFFICE

M516E

OFFICE

M516F

OFFICE

M516

OFFICESERVICEOFFICE

RESEARCHOFFICE

RESEARCHLAB

M528

14" EA UP (VR-103)

12" EA UP (VR-105)

10" EA UP (VR-104)

14" EA DN

14" EA UP (VR-49)

12" EA UP (VR-58)

12" EA DN

14" EA DN

10" EA UP(VR-47)

10"x6" DN

10" EA UP(VR-55)

14" EA UP(VR-50)

14" EA DN

14" EA UP (VR-51)

10" EA UP (VR-107)

16" EA UP (VR-43)

14" EA DN

16" EA DN

16" EA DN

16" EA UP (VR-44)

16" EA UP (VR-48)

12" EA UP (VR-110)

10" EA UP (VR-109)

14" EA UP (VR-53)

14" EA DN

14" EA UP (VR-52)

10" EA UP (VR-108)

24"x24" EA UP

14" DUCTCAPPED

1

1

1

1

1

1

1

EX FUMEHOOD TOREMAIN

EX FUMEHOOD TOREMAIN

EX FUMEHOOD TOREMAIN

EX FUMEHOOD TOREMAIN

EX FUME HOODTO REMAIN

2

2

2

40"x9" HOT 40"x10" COLD 32"x9" HOT 32"x10" COLD 30"x9" HOT 30"x10" COLD35"x9" HOT 36"x10" COLD

12"ø EA

16"ø EA

16"ø EA10"ø EA10"ø EA

28"x10" RA 20"x10" RA34"x11" RA

48"x11" RA

48"x

10"

RA

48"x10" RA

14"ø EA12"ø EA

10"ø

EA

16"ø EA

14"ø EA 12"ø EA

14"ø EA

12"ø EA

14"ø

EA

32"x10" RA36"x10" RA

32"x12" RA

30"x12" RA

11"x14" RA

12"x6" RA

12"x6" RA

12"x8"

12"x

4"

RA

18"x

6"

RA

18"x

8"

RA

10"ø EA12"ø EA

14"ø EA

16"x12" EA

3

4

4

1

1

1

T

T

T

T

1.

2.

3.

4.

5.

SEE M000 FOR GENERAL NOTES.

EXISTING EXHAUST DUCTWORK IS CONSTRUCTED OFTRANSITE, AN ASBESTOS CONTAINING MATERIAL.CONTRACTOR SHALL COORDINATE WITH THE ABATEMENTCONTRACTOR REGARDING THE DISCONNECTION ANDREMOVAL OF ASBESTOS-CONTAINING MATERIAL. ABATEMENTCONTRACTOR SHALL ASSUME FULL RESPONSIBILTY ANDLIABILITY FOR COMPLIANCE WITH ALL APPLICABLE FEDERAL,STATE, AND LOCAL REGULATIONS PERTAINING TO WORKPLACES, NOTIFICATIONS, HAULING, DISPOSAL, ANDPROTECTION OF WORKERS, VISITORS TO THE SITE, ANDPERSONS OCCUPYING AREAS ADJACENT TO THE SITE

ALL MECHANICAL DEMOLITION MATERIAL SHALL BE REMOVEDFROM THE BUILDING VIA SERVICE ELEVATOR LOCATED IN THEWEST WING (SEE KEY PLAN). PRIOR TO TRANSPORTING ANDDISPOSING OF DEMOLITION DEBRIS, COORDINATE WITHABATEMENT CONTRACTOR TO ENSURE BULK MATERIAL ISCOMPLETELY WRAPPED AND CONTAINED.

OPEN ENDS ON ALL EXISTING DUCTWORK SHALL BETEMPORARILY COVERED TO PREVENT MITIGATION OF DUSTFOLLOWING DEMOLITION.

CONTRACTOR SHALL REFER TO CONSTRUCTION PHASINGNOTES ON SHEET M000 AND FIFTH FLOOR CONSTRUCTIONPHASING PLAN ON SHEET M001 FOR INFORMATION REGARDINGREQUIREMENTS AND RESTRICTIONS ON ANY CONSTRUCTIONACTIVITIES IMPACTING BUILDING OPERATIONS AND SYSTEMS.

GENERAL NOTES:

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

2 P

M

505-106

MD102

DPP

FIFTH FLOOR DEMOLITIONPLAN

JCS

01/11/2017

1/8" = 1'-0"1

FIFTH FLOOR DUCTWORK DEMOLITIONPLAN

KEYED NOTES:

1 DEMOLISH EXISTING DUAL DUCT AIR TERMINAL UNIT ANDASSOCIATED DUCTWORK AS SHOWN. REMOVE ALL HANGERSAND SUPPORTS ASSOCIATED WITH DUCTWORK TO BEDEMOLISHED. REMOVE ASSOCIATED PNEUMATIC CONTROLSAND CAP MAIN AIRTIGHT WITH A BRASS COMPRESSION CAPTYPE FITTING. DO NOT PINCH OFF TUBING.

2 DEMOLISH EXISTING HOT AND COLD DECK MAIN DUCTS(STACKED) IN CORRIDOR AS SHOWN.

3 REMOVE SECTION OF HOT AND COLD SA DUCTWORK TOALLOW FOR INSTALLATION OF NEW MANUAL VOLUMEDAMPER.

4 REMOVE EXISTING SECTION OF TRANSITE DUCTWORK BACKTO NEAREST JOINT IN ACCORDANCE WITH GENERAL NOTE#2.

NORTH

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

#

1

1 01/20/17 ADDENDUM 1

Page 21: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

UPDN

18"x

8"

RA

84"x9"

84"x10"

66"x

9"

16"x66"

64"x

11"

RA

36"x10"

36"x10"

36"x

10"

SA

16"x8"

16"x8"

16"x8"

30"x14" RA

(BELOW)

48"x18" OA UP

36"x10" SA36"x9" SA

84"x10" SA84"x9" SA

(COLD TOP)

(HOT BOTTOM)

78"x

10"

24"x18" EA UP

42"x10" SA

90"x36" OA UP70"x30" OA UP

EXISTINGAHU-11

24"x

18"

30"x

14"

(BE

LO

W)

(BE

LO

W)

(CO

LD

)

42"x

9"

SA

24"x

9"

SA

42"x18" OA UP

12"x18" OA UP

MECH RM.

M524

(HO

T)

12"x66" RA

EXISTING OAPLENUM

RESEARCHLABORATORY

M531

RESEARCHLABORATORY

M531

RESEARCHOFFICE

M531

RESEARCHOFFICE

M530

RESEARCHOFFICE

M526

COOLER

M525

LAB

M534

MEN'SREST.

M536

WOMEN'SREST.

M535

RESEARCHLABORATORY

M523

1

2

3

4

5

6

7

8

3

4

7

(COLD)

(ABOVE)

EXISTING EADUCT TO REMAIN

14"x14" EA

16"x16" EA

7

24"x6" RA

1

ABANDONED EARISERS TO REMAIN(TYP 4)

EXISTING OALOUVER TO REMAIN

EXISTING OALOUVER TO REMAIN

EXISTING OALOUVER TO REMAIN

5

5

5

3

EA

RA

13

12" EA UP(VR-106)

14" EA UP(VR-101)

(COLD)

38"x

8"

24"x

8"

14"x

8"

14

14

14

14

TEMPORARILY CAPDUCT FOLLOWINGDEMOLITION

21

21

36"x9"(HOT)

12

12

12

WE

LD

ED

-SS

T D

UC

T

48"x12" RA

48"x

12"

RA

48"x

12"

RA

64"x11" RA

58"x9" SA30"x

9"

SA

T

T

T

T

1.

2.

3.

4.

5.

6.

SEE M000 FOR GENERAL NOTES.

CONTRACTOR SHALL REMOVE ALL EXISTING PNEUMATICCONTROLS ASSOCIATED WITH AHU-11. REMOVE ALLPNEUMATIC AIR TUBING WITHIN EXISTING MECHANICALROOM AND CAP MAIN AIRTIGHT WITH A BRASSCOMPRESSION CAP TYPE FITTING. DO NOT PINCH OFFTUBING.

EXISTING EXHAUST DUCTWORK IS CONSTRUCTED OFTRANSITE, AN ASBESTOS CONTAINING MATERIAL.ADDITIONALLY, EXISTING HVAC PIPING IS INSULATED WITHASBESTOS CONTAINING MATERIAL. CONTRACTOR SHALLCOORDINATE WITH THE ABATEMENT CONTRACTORREGARDING THE DISCONNECTION AND REMOVAL OFASBESTOS-CONTAINING MATERIAL. ABATEMENTCONTRACTOR SHALL ASSUME FULL RESPONSIBILTY ANDLIABILITY FOR COMPLIANCE WITH ALL APPLICABLEFEDERAL, STATE, AND LOCAL REGULATIONS PERTAINING TOWORK PLACES, NOTIFICATIONS, HAULING, DISPOSAL, ANDPROTECTION OF WORKERS, VISITORS TO THE SITE, ANDPERSONS OCCUPYING AREAS ADJACENT TO THE SITE

ALL MECHANICAL DEMOLITION MATERIAL SHALL BEREMOVED FROM THE BUILDING VIA SERVICE ELEVATORLOCATED IN THE WEST WING (SEE KEY PLAN). PRIOR TOTRANSPORTING AND DISPOSING OF DEMOLITION DEBRIS,COORDINATE WITH ABATEMENT CONTRACTOR TO ENSUREBULK MATERIAL IS COMPLETELY WRAPPED AND CONTAINED.

OPEN ENDS ON ALL EXISTING DUCTWORK SHALL BETEMPORARILY COVERED TO PREVENT MITIGATION OF DUSTFOLLOWING DEMOLITION.

CONTRACTOR SHALL REFER TO CONSTRUCTION PHASINGNOTES ON SHEET M000 FOR INFORMATION REGARDINGREQUIREMENTS AND RESTRICTIONS ON ANY CONSTRUCTIONACTIVITIES IMPACTING BUILDING OPERATIONS AND SYSTEMS

GENERAL NOTES:

MECHANICALROOMNE300

MECHANICALROOM

NE300A

8"LPS

EXISTINGAHU-22

44"x18"RELIEF

DUCTCAP

44"x40"RELIEF

9

10

9

EXISTINGABANDONEDEXHAUSTRISERS

6" CWR

6" CWS

20

20

WOMEN'SRESTROOM

M239

MECHANICALROOM

M236

JANITORSCLOSET

M237

EXISTINGAHU-36

EXISTINGEXPANSIONTANK

EXISTINGEXHAUSTRISERS

36"x30" EA

24"x30" EA

11

11

HWS/HWRRISERS

11

3" LPR UP/DN8" LPS UP6" CWR UP6" CWS FROM ABOVE

EXISTING AHU-11

15 16

MECHANICALROOM

M523

EX

IST

. 6"

LP

S

EX

IST

. 4"

CW

R

EX

IST

. 4"

CW

S

16

15

16

15

17

17

1 1

/2"L

PR

BLOWERROOMNE400

BLOWERROOM

NE400A

8"LPS

EXISTING AHU-16

44"x18"

44"x40"RELIEF

RELIEF

9

10

EXISTINGABANDONEDEXHAUSTRISERS (TYP 4)

18

24"x24"EA

6" CWSUP/DN

6" CWRUP/DN

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

3 P

M

505-106

MD103

DPP

ENLARGED DEMOLITIONPLANS

JCS

01/11/2017

KEYED NOTES:

1 REMOVE SECTION OF 24x18 EA DUCT TO ALLOW FORINSTALLATION OF NEW CWS/R AND HWS/R RISERS.COORDINATE TEMPORARY SHUTDOWN OF EXHAUST SYSTEMWITH OWNER'S REPRESENTATIVE WITH MINIMUM TWO (2)WEEKS ADVANCE NOTICE.

2 DEMOLISH EXISTING AIR HANDLING UNIT ALONG WITHASSOCIATED HOT AND COLD DECK SUPPLY AIR, OUTSIDEAIR, AND RETURN AIR DUCTWORK AS SHOWN. CONTRACTORSHALL COMPLETELY REMOVE ALL HANGERS AND SUPPORTSASSOCIATED WITH DEMOLISHED DUCTWORK.

3 REMOVE RETURN AIR DUCTWORK RUNNING BENEATHOUTSIDE AIR PLENUM. TEMPORARILY CAP DUCT FOLLOWINGDEMOLITION.

4 TEMPORARILY BLANK OFF EXISTING LOUVERS FOLLOWINGREMOVAL OF OUTSIDE AIR PLENUM.

5 CAP EXISITNG OUTSIDE AIR DUCT AT SLAB.

6 EXISTING TEMPERATURE CONTROL PANEL ANDCONTROLLER TO BE REMOVED BY OWNER PRIOR TODEMOLITION. OWNER SHALL HAVE SALVAGE RIGHTS TO ALLFIELD CONTROL DEVICES ASSOCIATED WITH EXISTING AHUPRIOR TO START OF DEMOLITION. CONTRACTOR SHALLREMOVE ALL AHU-11 CONTROLS COMPONENTS NOTSALVAGED BY OWNER. REMOVE EXISTING PNEUMATICCONTROLS HARDWARE AND DEVICES IN ACCORDANCE WITHGENERAL NOTE 2.

7 DEMOLISH SECTION OF EXISTING RETURN AIR DUCTWORKAS SHOWN. CAP DUCT AT WALL AS SHOWN ON SECTION CON M301.

8 REMOVE SECTION OF DUCTWORK TO ALLOW FORINSTALLATION OF NEW MANUAL VOLUME DAMPER.

9 REMOVE EXISTING RELIEF AIR DUCTWORK AND ALLASSOCIATED HANGERS AND SUPPORTS. CAP REMAININGSECTION OF DUCT AT WALL.

10 PERMANENTLY BLANK OFF EXISTING RELIEF AIR LOUVERWITH AN INSULATED BLANK OFF PANEL. BLANK OFF PANELSHALL BE PAINT GRIP SHEET METAL PAINTED FLAT BLACKFACING EXTERIOR WITH 2" RIGID POLYISOCYANURATEBOARD INSULATED ENCAPSULATED BY A SECOND PIECE OFPAINT GRIP SHEET METAL PAINTED FLAT BLACK FACINGMECHANICAL ROOM SO NO INSULATION IS EXPOSED.INSULATION FLAME AND SMOKE SHALL MEET 25/50 RATINGS.PROVIDE AIRTIGHT SEAL BETWEEN BLANK OFF PANEL ANDLOUVER.

11 DEMOLISH EXISTING ABANDONED AIR HANDLING UNIT AH-36AND ALL ASSOCIATED DUCTWORK, PIPING, VALVES ANDOTHER HYDRONIC ACCESSORIES, AND ALL HANGERS ANDSUPPORTS. DEMOLISH ALL ASSOCIATED PNEUMATICTEMPERATURE CONTROLS INCLUDING ALL ACCESSIBLEPNEUMATIC TUBING. CAP EXISTING PNEUMATIC TUBING ATMAIN WITH A BRASS COMPRESSION CAP TYPE FITTING; DONOT PINCH OFF TUBING. DEMOLISH ASSOCIATED HWS/HWRPIPES DOWN TO FLOOR AND CAP. COORDINATE ANYREQUIRED OUTAGE OF STEAM SYSTEM WITH OWNER'SREPRESENTATIVE.

12 REMOVE SECTION OF EXISTING TRANSITE DUCTWORK BACKTO POINT OF CONNECTION WITH WELDED-SST DUCTWORKALONG WITH ASSOCIATED GRILLES, HANGERS, ANDSUPPORTS IN ACCORDANCE WITH GENERAL NOTE #3.

13 REMOVE EXISTING ABANDONED FLEX DUCT.

14 DEMOLISH EXISTING DUAL DUCT AIR TERMINAL UNIT ANDASSOCIATED DUCTWORK AS SHOWN. REMOVE ALL HANGERSAND SUPPORTS ASSOCIATED WITH DUCTWORK TO BEDEMOLISHED. REMOVE ASSOCIATED PNEUMATIC CONTROLSAND PROVIDE AN AIRTIGHT CAP AT MAIN CONTROL AIR LINE.

15 DEMO ALL EXISTING LPS AND LPR PIPING BACK TO MAIN ANDCAP. REMOVE ALL ASSOCIATED VALVES, TRAPS, ANDACCESSORIES, AND ALL ASSOCIATED HANGERS ANDSUPPORTS. COORDINATE ANY REQUIRED OUTAGE OF STEAMSYSTEM WITH OWNER'S REPRESENTATIVE. NOTE THATEXISTING STEAM SHUTOFF VALVE IS IN POOR CONDITION. IFVALVE IS UNABLE TO COMPLETELY SHUTOFF STEAMSUPPLY, STOP DEMOLITION WORK AND NOTIFY OWNER'SREPRESENTATIVE IMMEDIATELY.

16 DEMO EXISTING CHILLED WATER PIPING BACK TO MAIN,ALONG WITH ALL ASSOCIATED HANGERS AND SUPPORTS.CAP PIPES AT MAIN.

17 DEMOLISH EXISTING AIR HANDLING UNIT ALONG WITH ALLASSOCIATED COIL AND DRAIN PIPING, SUPPORTS, VALVES,AND APPURTENANCES.

18 DEMOLISH LENGTH OF EXISTING EXHAUST DUCT ASREQUIRED TO MAKE NEW CONNECTION. SEE M201 FOR NEWDUCTWORK.

19 REMOVE CWS/R RISER AND DISCONNECT AHU-16 BRANCHPIPING. DEMOLITION SHALL TERMINATE AT UNDERSIDE OF5TH FLOOR SLAB. PREPARE PIPE FOR NEW CONNECTION.

20 REMOVE CWS/R RISER AND DISCONNECT AHU-22 BRANCHPIPING. INFILL OPENINGS IN SLAB.

21 DEMOLISH EXISTING HOT AND COLD DECK MAIN DUCTS(STACKED) IN CORRIDOR AS SHOWN.

1/4" = 1'-0"1

ENLARGED FIFTH FLOOR DUCTWORKDEMOLITION PLAN

NORTH

#

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

1/8" = 1'-0"4

PARTIAL THIRD FLOOR DEMOLITION PLAN

1/4" = 1'-0"3

PARTIAL SECOND FLOOR DEMOLITION PLAN

NORTH

NORTH

1/4" = 1'-0"2

FIFTH FLOOR PIPING DEMOLITION PLAN

NORTH

1/8" = 1'-0"5

PARTIAL FOURTH FLOOR DEMOLITION PLAN

NORTH

19

19

1

1 01/20/17 ADDENDUM 1

Page 22: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

DN

LOCKERS LOCKERSLOCKERS LOCKERS

LOCKERS

LOCKERS

LOCKERS

LOCKERS

LOCKERS LOCKERS

LOCKERS

526

527

EXTERIOR STAIR

(STAIRWAY TAKENOUT OF SERVICE)

UPDN

CW

R

CW

S

LPSLPSLPS

EX 6"HWSEX 6"HWR

INSTRUCTIONAL LABGROSS ANATOMY

M148

INSTRUCTIONALLAB

M134

INSTRUCTIONALLAB

M133

INSTRUCTIONALLAB

M132

INSTRUCTIONALLAB

M131

INSTRUCTIONALLAB

M126

JANITOR

M125A

TELECOM

M125

ELECSTO

MY100A

EX 2 1/2"HWSEX 2 1/2"HWREX 4" CWSEX 4" CWR

6" HWSUP/DOWN6" HWRUP/DOWN

12" CWSUP/DOWN12" CWRUP/DOWN

10" HWRUP/DOWN10" HWSUP/DOWN

EXISTING LPSTO REMAIN

EXISTING LPSTO REMAIN

6"CWS

6" HWR6" HWS

NEW PIPERISERS6" HWS6" HWR6" CWS6" CWR

ABANDONEDPIPING

#2

2 2

2

2

2

2 2

2

3

3

3

3

6" CWS6" CWR

6" CWS6" CWR

6" CWS6" CWR

6" CWS

6" CWR

6" CWS

6" CWR

1 LAB ENTRY

M144

UNEMBALMEDLAB

M144C

EMBALMEDLAB

M144B

DRESSROOM

M144A

CHEMSTOR

M144B-1

2

2

CORR

M1452

CORR

M122

STORAGE

M125B

6"HWR6"HWS

6"HWR6"HWS

5

6

6

7

8

8

9

12

12

6"CWR

6"CWS13

EXABANDONEDDUCTS

15

15

20

20

20 20EXISTINGSERVICEELEVATOR

WOMEN'SRESTROOM

M239

MECHANICALROOM

M236

JANITORSCLOSET

M237

3

3

6"CWR

6"CWS

6"HWS

UP

UP

FROMABOVE

FROMABOVE

6"CWRDN

6"CWSFROMBELOW

DN

6"HWR

DN

6"HWS

4

4

4

4

16

17

17

MECHANICALROOM

NE300

MECHANICALROOM

NE300A

6"C

WS

6"C

WR

6"CWR

6"CWS

6"HWR

6"HWS

FROMABOVE

UP

UP

FROMABOVE

8"LPSEX

EX CWS/RTO AH-22

10

10 UP

4

EXISTING AHU-22

4

SECURE PIPES TOWALL. ROUTERISERS CLOSE TOWALL MAXIMUMACCESS IN MECHRM

6"CWS FROM ABOVE6"CWR UP

BLOWERROOM

NE400

BLOWERROOM

NE400A

3

8"LPSEX

4

EX CWS/R TO AHU-16

UP/DN

6"HWR

FROM BELOW

DN

EXISTING AHU-16

6"H

WS

6"H

WR

2 1/2"HWS

2 1/2"HWR

2-1/2" HWS/R UPTO AHU-11

6"HWS

6"HWR

6"HWS

6" HWS/R UP TO MECHRM 524 ABOVE

11

11

6"CWR UP

6"CWS FROM ABOVE

1010

18

18

6"CWSDN

6"CWRFROMBELOW

1919

1

1.

2.

SEE M000 FOR GENERAL NOTES.

CONTRACTOR SHALL REFER TO CONSTRUCTIONPHASING NOTES ON SHEET M000 FOR INFORMATIONREGARDING REQUIREMENTS AND RESTRICTIONS ONANY CONSTRUCTION ACTIVITIES IMPACTING BUILDINGOPERATIONS AND SYSTEMS

GENERAL NOTES:

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

5 P

M

505-106

M101

DPP

PIPING NEW WORK PLANS

JCS

01/11/2017

1/8" = 1'-0"1

FIRST FLOOR PIPING NEW WORK PLAN

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

NORTH

#

1/4" = 1'-0"2

PARTIAL SECOND FLOOR PIPING NEWWORK PLAN

NORTH

1/4" = 1'-0"3

PARTIAL THIRD FLOOR PIPING NEW WORKPLAN

NORTH

1/4" = 1'-0"4

PARTIAL FOURTH FLOOR PIPING NEWWORK PLAN

NORTH

KEYED NOTES:

1 PROVIDE 10" TO 6" TRANSITION TO CONNECT TOEXISTING 10" SHUTOFF VALVES.

2 REMOVE AND REINSTALL EXISTING ACOUSTICALCEILING TILES AND GRID IN THIS ROOM TO ALLOWFOR INSTALLATION OF NEW PIPING. STORE TILES INSAFE PLACE, FREE OF OBSTRUCTION TO MINIMIZEDAMAGE. REPLACE ANY DAMAGED TILES TO THESATISFACTION OF THE OWNER.

3 NO CEILING EXISTS IN THIS SPACE.

4 4-INCH VALVED AND CAPPED CONNECTION FORFUTURE USE.

5 ROUTE PIPES VERTICALLY STACKED THROUGHWALL.

6 ROUTE PIPES THROUGH PATH OF EXISTINGABANDONED DUCTWORK DEMOLISHED AS WORK OFTHIS PROJECT. PATCH WALL OPENING TO INFILLVOID LEFT BY DEMOLISHED DUCTWORK FOLLOWINGINSTALLATION OF NEW PIPES.

7 OFFSET PIPES TO AVOID EXISTING DUCTWORK.ROUTE PIPE OVER DUCTWORK.

8 HOLD PIPES TIGHT TO STRUCTURE.

9 PROVIDE NEW SHUTOFF VALVES AT LOCATIONSHOWN PER SPEC. PROVIDE 6" TO 4" REDUCER JUSTUPSTREAM OF VALVES.

10 EXTEND NEW AHU BRANCH PIPING TO NEW CHILLEDWATER RISERS AS SHOWN. FIELD VERIFY EXISTINGPIPE SIZE.

11 PROVIDE 3/4" VALVED HOSE END DRAIN FOR 5THFLOOR PIPING.

12 PROVIDE 3/4" VALVED HOSE END DRAINCONNECTION FOR NEW RISERS.

13 ROUTE NEW HWS/R PIPES BENEATH EXISTINGABANDONED DUCTWORK AS SHOWN.

14 WORK WITHIN THIS BOUNDARY SHALL BEPERFORMED ONLY WHEN MEDICAL SCIENCESBUILDING IS SCHEDULED TO BE UNOCCUPIEDBETWEEN MARCH 4, 2017 AND MARCH 12, 2017.REFER TO CONSTRUCTION PHASING NOTE #1 ONM000 FOR MORE INFORMATION.

15 PROVIDE 6" TO 2-1/2" REDUCER TO CONNECT NEWAND EXISTING PIPING.

16 ROUTE PIPE AS CLOSE TO WALL AS POSSIBLE TOAVOID RESTRICTING ACCESS TO JANITORS CLOSET.

17 ALL HORIZONTAL PIPING IN THIS SPACE SHALL BEINSTALLED AS HIGH AS POSSIBLE, TIGHT TOSTRUCTURE.

18 CONNECT NEW 6" RISER TO EXISTING ATUNDERSIDE OF 5TH FLOOR SLAB.

19 HOLD NEW PIPING TIGHT TO SLAB

20 FOR ALL SPACES WITHIN THIS BOUNDARY,CONTRACTOR SHALL COMPLETELY COVER ALLFURNITURE, COUNTERTOPS, AND EQUIPMENT WITHPROTECTIVE PLASTIC SHEETING TO PREVENTDAMAGE. TEMPORARY PROTECTIVE COVERINGSHALL REMAIN IN PLACE UNTIL COMPLETION OFWORK IN THIS AREA. UPON COMPLETION OF WORK,CONTRACTOR SHALL WIPE DOWN COUNTERS,TABLES, AND FURNITURE, AND VACUUM ASNECESSARY TO RETURN SPACE TO ORIGINALCONDITION PRIOR TO CONSTRUCTION.

3

14

14 14

14

14

1

1

1 01/20/17 ADDENDUM 1

Page 23: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

ROOF

SCHOOL OF NURSING

18"x

8"

RA

16"x8" SA16"x8" SA16"x8" SA16"x8" SA30"x

9"

SA

58"x10"(BOTTOM)

58"x9"(TOP)

30"x9" (TOP)30"x10" (BOTTOM)

42"x

9"

SA

24"x

9"

SA

60"x10" SARHC

5-1

66"x9" SA

RESEARCHLABORATORY

M531

RESEARCHOFFICE

M533

RESEARCHOFFICE

M530

RESEARCHOFFICE

M526

COOLER

M525

RESEARCHLABORATORY

M529

MEN'SREST.

M536

WOMEN'SREST.

M535

CORRIDOR

M517

RESEARCHLABORATORY

M523

RESEARCHLABORATORY

M522

MECHANICALROOM

M524

MD

1

30"x10"(BOTTOM)

30"x9"(TOP)

30"x10"(BOTTOM)

30"x9"(TOP)

1

M201

34"x11" RA 28"x10" RA 20"x10" RA 12"x6" RA

48"x10" RA

48"x12" RA

48"x

12"

RA

10"ø

EA

16"x

16"

RA

16"x

16"

RA

10"ø EA16"ø EA

16"ø EA

12"ø EA

14"ø EA

12"ø EA14"ø EA

14"ø EA

40"x9" SA 32"x9" SA 36"x9" SA 30"x9" SA40"x10" SA 32"x10" SA 36"x10" SA 30"x10" SA

36"x10" RA 32"x10" RA

32"x12" RA

(BOTTOM)(TOP) (BOTTOM)(TOP) (BOTTOM)(TOP) (BOTTOM)(TOP)

6"ø SA

(TYP 2)

155CFM

155CFM

8"ø

SA

VAV

550

VAV

551

24"x14" SA

600CFM

60"x10" SA

TISSUECULTURE

M521

CELLCULTURE

M519A

RESEARCHOFFICE

M520

RESEARCHLABORATORY

M519

RESEARCHLABORATORY

M518

MICROSCOPELAB

M518B

MICROSCOPELAB

M518C

OFFICE

M517C

M516ARESEARCH

LABORATORY

M514

RESEARCHLABORATORY

M512

RESEARCHOFFICE

M512A

M511

RESEARCHLABORATORY

M509LABSERV

M508

RESEARCHLABORATORY

M506

M505RESEARCHOFFICE

M503A

RESEARCHLABORATORY

M504

RESEARCHLABORATORY

M503

RESEARCHLABORATORY

M538

RESEARCHLABORATORY

M537

MICROSCOPELAB

M518A

OFFICE

M516B

OFFICE

M516C

OFFICEM516D

OFFICE

M516E

OFFICE

M516F

OFFICE

M516

OFFICESERVICEOFFICE

RESEARCHOFFICE

RESEARCHLAB

M528

450CFM

450CFM

E-1

500

E-1

500

E-3

250

E-1

450

E-2

150

10"ø EA

8"ø EA

12"x

4"

RA

14" EA UP (VR-103)

12" EA UP (VR-105)

10" EA UP (VR-104)

14"ø EA

12"ø EA10"ø EA

14" EA DN

12" EA UP (VR-106)

14" EA UP (VR-101)

14" EA UP (VR-49)

12" EA UP (VR-58)

12" EA DN

14" EA DN

10" EA UP(VR-47)

10"x6" DN

10" EA UP(VR-55)

14" EA UP(VR-50)

14" EA DN

14" EA UP (VR-51)

10" EA UP (VR-107)

16" EA UP (VR-43)

14" EA DN

16" EA DN

14"ø

EA

16"ø

EA

16" EA DN

16" EA UP (VR-44)

16" EA UP (VR-48)

12" EA UP (VR-110)

10" EA UP (VR-109)

14" EA UP (VR-53)

14" EA DN

14" EA UP (VR-52)

10" EA UP (VR-108)

24"x24" EA UP

E-1

500

E-1

500

E-4

60010"ø EA

14" FLEXDUCT

800CFM

E-1

500

500CFM

450CFM

E-1

550

1

500CFM

250CFM

250CFM

2

400CFM

3

3

3

12"ø EA

4

4

4

4

P

5

6

7

8

P

12"x8" SA

VAV

553

24"x12" SA

20"x

10"

SA

S-2

335

S-2

3359

9VAV

554

40"x

12"

SA

VAV

557

S-3

250

S-3

250

150CFM

10

S-2

40014"x14" SA

9

12"ø SA

S-4

400

100CFM

10

3

3

10S-4

4009

VAV

556

VAV

555

VAV

558

CORRIDOR

M529

14"x12" SA

12"x8" SA

10

20"x10" SA

S-2

300

11

11

(SST) (SST)12"ø EA

12"ø EA(SST)

22"x8" EA (SST)

10"ø EA(SST)

1

1

31

16"x

8"

SA

1

12

12

8"ø SA(TYP 2)

1

2

3

4

5

6

SEE M000 FOR GENERAL NOTES.

WORK OF THIS PROJECT INVOLVES CONVERTINGTHE AHU-11 AIR HANDLING SYSTEM FROM MINIMUMOUTSIDE AIR TO 100% OUTSIDE AIR. FOLLOWINGINSTALLATION OF NEW AHU, ALL EXISTING RETURNAIR DUCTWORK WILL ACT AS EXHAUST AIRDUCTWORK.

BALANCE EXISTING AND NEW EXHAUST DEVICES TOAIRFLOWS NOTED ON PLAN. REFER TO SHEET M103FOR BALANCING OF INDIVIDUAL EXHAUST RISERS.

UNLESS NOTED OTHERWISE, ALL SPACES HAVE NOCEILING (EXPOSED STRUCTURE).

CONTRACTOR SHALL REFER TO CONSTRUCTIONPHASING NOTES ON SHEET M000 AND FIFTH FLOORCONSTRUCTION PHASING PLAN ON SHEET M001FOR INFORMATION REGARDING REQUIREMENTSAND RESTRICTIONS ON ANY CONSTRUCTIONACTIVITIES IMPACTING BUILDING OPERATIONS ANDSYSTEMS.

FOR EACH LAB SERVED BY AHU-11, EXISTINGSUPPLY AIRFLOW SHALL BE MEASURED ANDADJUSTED AS NECESSARY TO ENSURE THAT LAB ISNEGATIVELY PRESSURIZED (MINIMUM 100 CFMOFFSET BETWEEN SA AND EA). LAB SUPPLYAIRFLOW SHALL BE MEASURED DOWNSTREAM OFEACH EXISTING DUAL DUCT TERMINAL UNIT.

GENERAL NOTES:

NOTE:FITTINGS SHALL BE PROVIDED BY DIV 23AND INSTALLED BY ABATEMENT CONTRACTOR.

STAINLESSSTEELDRAWBANDS

SEALANT AROUND DUCT ATEACH END OF SLEEVE ANDALONG LONGITUDINAL SEAM

1" OVERLAP

FASTENERS AT TOP ANDBOTTOM OF SST FITTING(TYP BOTH SIDES)

SST SHEETMETALSADDLE FITTINGS

TRANSITE DUCTNEW DUCT PERSPECIFICATION

EXISTINGTRANSITE DUCT

NEW DUCT PERSPECIFICATION

EXISTINGTRANSITE DUCT

1

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

6 P

M

505-106

M102

DPP

FIFTH FLOOR DUCTWORKNEW WORK PLAN

JCS

01/11/2017

1/8" = 1'-0"1

FIFTH FLOOR DUCTWORK NEW WORK PLAN

NORTH

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

KEYED NOTES:

1 REMOVE EXISTING 18x10 EA GRILLE, EXPANDOPENING IN DUCT, AND INSTALL NEW E-1 GRILLE ASSHOWN.

2 EXISTING MANUAL VOLUME DAMPER. BALANCEDUCT TO AIRFLOWS NOTED ON PLAN.

3 REMOVE AND REINSTALL EXISTING ACOUSTICALCEILING TILES AND GRID IN THIS ROOM TO ALLOWFOR INSTALLATION OF NEW DUCTWORK. STORETILES IN SAFE PLACE, FREE OF OBSTRUCTION TOMINIMIZE DAMAGE. REPLACE ANY DAMAGED GRIDAND CEILING TILES TO THE SATISFACTION OF THEOWNER.

4 BALANCE EXISTING FUME HOOD TO AIRFLOW NOTEDON PLAN. COORDINATE WITH OWNER'SREPRESENTATIVE FOR BALANCING ANDCERTIFICATION OF FUME HOODS.

5 LOCATION FOR NORTH SA DUCT STATIC PRESSURESENSOR.

6 LOCATION FOR SOUTH HOT AND COLD DUCT STATICPRESSURE SENSORS.

7 MOTORIZED DAMPER SHALL BE FURNISHED WITHVERTICAL BLADES AND BOTTOM ACTUATOR.

8 INSTALL NEW MANUAL VOLUME DAMPERS IN HOTAND COLD DECK SA DUCTS AS SHOWN.

9 PROVIDE MANUAL VOLUME DAMPER IN 12" VERTICALTAP.

10 BALANCE EXISTING AIR DEVICE TO AIRFLOW NOTEDON PLAN.

11 ROUTE NEW SA MAIN AS HIGH AS POSSIBLE TOALLOW SUFFICIENT SPACE FOR NEW HWS/R PIPESTO PASS UNDERNEATH.

12 PROVIDE SHEETMETAL ESCUTCHEOON AT WALLPENETRATION. PATCH AND PAINT WALL TO MATCHEXISTING, IF DAMAGED. COORDINATE PAINT COLORWITH OWNER'S REPRESENTATIVE.

EA

EA EA

EAEAEAEA

EA

EA

EA

EA

EA

EA

EA

#

NO SCALE2

EXHAUST DUCT FITTING DETAIL

1

1 01/20/17 ADDENDUM 1

Page 24: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

M

M

UP

18"x

8"

RA

64"x

11"

RA

16"x8" SA16"x8" SA16"x8" SA16"x8" SA

30"x

9"

SA

36"x10" SA

36"x10" SA

30"x14" RA

24"x18" EA UP

42"x10" SA

58"x10"(BOTTOM)

58"x9"(TOP)

42"x

9"

SA

24"x

9"

SA

(HOT)

66"x18" SA

70"x16" SA

RHC

5-1

30"x86" OA

24"x

86"

OA

EXISTING ELECTRICALBUS DUCT TO REMAIN

(VR-2)

58"x9" SA

40"x

12"

SA

16"x40" EAUP TO 7TH FLOOR. SEEPLAN #4 ON THIS SHEETFOR CONTINUATION

ABANDONED EARISERS TO REMAIN(TYP 4)

16"x56" RA

66"x9" SA

COOLER

M525

RESEARCHLABORATORY

M523

MECHANICALROOM

M524

18"x8" RA

14"x10" RA68"x60" OA

FC

FC

66"x10" SA

46"x14" RA

(BELOW)

(ABOVE)

MD

1

1

2

48"x60" OA

3

3

4

5

5

16"x56" RA

12"x66" RA

EA

EA

EA

EA

EA

EA

EA

(COLD)

EA

EA

(HO

T)

(HO

T)

(HO

T)

(HOT)(COLD) (COLD)

HOT

COLD

COLD

(COLD)

(CO

LD

)

66"x18" SA(COLD)

76"x10" SA(ABOVE)

B

M301

A

M301

AHU

11

C

M301

VAV

551

8"ø

SA

6"ø SA

60"x

10"

SA

6

7

D

M301

11

3,600 CFMEA

12

66"x10" SA (COLD)

15

S-1

250

14"x10" SA

(BELOW)VAV

552

E-1

250

14"x10" RA

POSITION PLENUM TOAVOID EXISTING PLUMBINGPIPES IN THIS AREA. SEEP-SERIES SHEETS.

16

16

16

PLE

NU

M

PLENUM

MD

2

MD

317

17

18

18

18

EA

18x18 BOTTOMACCESS DOOR

AD

40"x12" SA

E-1

500

14"ø

EA

VAV

558

19

19

S-4

400

1

66"x10" SA

SHOETAP

1

1' -

2"

22

14"x24" EA(BELOW)

BLOWERROOM

NE400

MECHRM

NE400A

18"x

24"

EA

UP

HOLD DUCT TIGHTTO STRUCTURE

36"x30" EA24"x30" EA

18"x24" EA

8"x24" EA

SEE PLAN #1 ON THISSHEET FOR CONTINUATION

EXISTINGAHU-16

RESEARCHLABORATORY

M531

RESEARCHLABORATORY

M531

RESEARCHOFFICE

M533

RESEARCHOFFICE

M530

RESEARCHOFFICE

M526

RESEARCHOFFICE

M527

RESEARCHLABORATORY

M529

LAB

M534

MEN'SREST.

M536

WOMEN'SREST.

M535

COOLER

M525

MECHANICALROOM

M523

COOLING COIL

HUMIDIFIER

PREHEAT COIL

RHC

5-1

2"L

PS

4"C

WR

4"C

WS

1 1/2"HWR

1 1/2"HWS

1 1

/2"H

WR

1-1/2"HWS/R

FD

2"D

10

10

T

EXISTING LAB UTILITYPIPING TO REMAIN

HWRP

11

B

M301

A

M301

VAV

551

1 1/2"LPR

1"HWR

1"HWS

3/4

"HW

R

3/4

"HW

S

3/4"HWR

3/4"HWS

T

T

2-1/2" HWSFROM BELOW

2-1/2" HWR DN

1"LPR

1"LPR

4"ST

4"D

8

8"LPS

6"CWS

6"CWR

FROM BELOW

FROM BELOW

DN

13

13

14

DISCHARGEPLENUM

VAV

552

T

3/4"

1 1

/2"H

WS

T

T

TT

T

T

VAV

557

VAV

556

VAV

555

VAV

554

VAV

553

VAV

558

VAV

550

1 1/2"HWS1 1/2"HWR

1 1

/2"H

WS

1 1

/2"H

WR

1 1

/2"H

WS

1 1

/2"H

WR

3/4

"HW

S

3/4

"HW

R

1"HWR

1"HWS

3/4"HWR

3/4"HWS

20

6"HWR

6"HWS FROM BELOW

UP

1 1/2"HWS

1 1/2"HWR

RHC 5-1SHUTOFFVALVES

6"HWR

6"HWS

FROMABOVE

UP21

21

2 1/2"HWR

2 1/2"HWS

1

24"x18" EA

24"x18" EA

24"x24" EAUP TO ROOF

24"x24" EAUP TO ROOF

STAIRS

MW700

FACULTYOFFICE

M712

CORRIDOR

M723

D

M301

24"x24" EA

18"x18" EA

18"x18" EA

16"x40" EA

FROMBELOW

9

24"x18"EA DN

24"x18"EA DN

1

2

3

4

SEE M000 FOR GENERAL NOTES.

WORK OF THIS PROJECT INVOLVES CONVERTINGTHE AHU-11 AIR HANDLING SYSTEM FROM MINIMUMOUTSIDE AIR TO 100% OUTSIDE AIR. FOLLOWINGINSTALLATION OF NEW AHU, ALL EXISTING RETURNAIR DUCTWORK WILL ACT AS EXHAUST AIRDUCTWORK.

CONTRACTOR SHALL REFER TO CONSTRUCTIONPHASING NOTES ON SHEET M000 AND FIFTH FLOORCONSTRUCTION PHASING PLAN ON SHEET M001FOR INFORMATION REGARDING REQUIREMENTSAND RESTRICTIONS ON ANY CONSTRUCTIONACTIVITIES IMPACTING BUILDING OPERATIONS ANDSYSTEMS.

HWS AND HWR RUNOUTS TO AIR TERMINAL UNITSSHALL MEASURE MINIMUM 3/4".

GENERAL NOTES:

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

8 P

M

505-106

M201

DPP

ENLARGED NEW WORKPLANS

JCS

01/11/2017

1/4" = 1'-0"1

ENLARGED FIFTH FLOOR DUCTWORK NEWWORK PLAN

1/4" = 1'-0"3

PARTIAL FOURTH FLOOR DUCTWORK NEWWORK PLAN

KEYED NOTES:

1 CAP END OF EXISTING RETURN DUCT (BELOW)AIRTIGHT.

2 TRANSITION DUCT TO 66x10 TO MAKE ROOM FORRHC 5-2 HWS/R PIPING.

3 CONNECT NEW OA DUCTWORK TO EXISTING60-INCH TALL LOUVER.

4 CONNECT NEW 24x18 EA DUCT TO EXISTING RISER.

5 EXPOSED LOUVER AREA ADJACENT TO EXISTINGRA DUCT SHALL BE COVERED WITH AN INSULATEDBLANK-OFF PANEL. BLANK-OFF PANEL SHALL BEPAINT GRIP SHEET METAL PAINTED FLAT BLACKFACING EXTERIOR WITH 2" RIGIDPOLYISOCYANURATE BOARD INSULATIONENCAPSULATED BY A SECOND PIECE OF PAINTGRIP SHEET METAL PAINTED FLAT BLACK FACINGMECHANICAL ROOM SO NO INSULATION ISEXPOSED. INSULATION FLAME AND SMOKE SHALLMEET 25/50 RATINGS. PROVIDE AIRTIGHT SEALBETWEEN DUCT, BLANK-OFF PANEL, ADJACENTOUTSIDE AIR DUCT, AND LOUVER.

6 PROVIDE 2-FT WIDE BY 7-FT TALL INSULATEDACCESS DOOR AT END OF INSULATED OA PLENUM.

7 UNIT SHALL SIT DIRECTLY ON FACTORY 10-INCHTALL BASE RAIL.

8 EMCS PANEL. MAINTAIN 42" CLEAR IN FRONT OFPANEL.

9 CONNECT NEW 18x18 EA DUCT TO EXISTINGOPEN-ENDED 18x18 EA DUCT.

10 COIL PULL CLEARANCE. KEEP AREA FREE OFOBSTRUCTION.

11 NEW RA MANUAL BALANCE DAMPER. BALANCEDUCT TO 1,050 CFM.

12 BALANCE DUCT TO 2,000 CFM.

13 PIPE CONDENSATE DRAIN LINE AT 1% SLOPE TOEXISTING FLOOR DRAIN. TURN PIPE DOWN TODISCHARGE INTO DRAIN.

14 4-INCH VALVED AND CAPPED CONNECTION FORFUTURE USE. COORDINATE LOCATION WITH RHC5-1 RUNOUTS SO VALVES ARE EASILYACCESSIBLE.

15 BALANCE DUCT TO 300 CFM.

16 OFFSET DUCTWORK TO AVOID EXISTING STORMDRAIN, WASTE LINE, AND FIRE MAIN. SEE P- ANDFP-SERIES SHEETS.

17 SURFACE MOUNT OA DAMPER IN PLENUM SOACTUATOR IS ACCESSIBLE FROM PLENUM.

18 FLOOR OF OUTSIDE AIR PLENUM SHALL BE RATEDFOR 250 LBS MINIMUM.

19 ROUTE NEW SA MAIN AS HIGH AS POSSIBLE TOALLOW SUFFICIENT SPACE FOR NEW HWS/R PIPESTO PASS UNDERNEATH.

20 PROVIDE AUTOFLOW BALANCE VALVE SET TO 1.0GPM.

21 PROVIDE 6-INCH VALVED AND BLIND FLANGEDCONNECTION FOR FUTURE USE TO SERVEFLOORS ABOVE.

22 MAINTAIN MAXIMUM CLEARANCE BETWEEN 14x24EA DUCT AND EXISTING BUS RISER TO ALLOW FORPOSSIBLE FUTURE INSTALLATION OF MAXIMUMALLOWABLE BUS PLUG. 14x24 EA DUCT SHALLTRANSITION BACK TO 24x18 AS HIGH AS POSSIBLE.

1/4" = 1'-0"2

ENLARGED FIFTH FLOOR PIPING NEWWORK PLAN

NORTH

NORTH

NORTH

1/4" = 1'-0"4

PARTIAL SEVENTH FLOOR DUCTWORK NEWWORK PLAN

NORTH

SUPPLY AIR FROM AHU-11: 12,000 CFM (LIMITED VIA EMCS - SEE M701)

EXHAUST AIR FROM EXISTING RISERS: -8,550 CFM

EXHAUST AIR FROM NEW EA RISER IN MECH ROOM M524: -3,600 CFM________________________________________________________________

FIFTH FLOOR EAST: -150 CFM WITH RESPECT TO ADJACENT CORRIDOR

FIFTH FLOOR EAST AIR BALANCE

KEY PLAN

EAST WINGWEST WING

NORTHWESTWING

NORTHEASTWING

SOUTHWING

SCOPEAREA

LOCATIONOF SERVICEELEVATOR

#

1

1 01/20/17 ADDENDUM 1

Page 25: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

Level 553' - 0"

Level 664' - 3"

Level 5 Btm of Beam63' - 0"

B

M301

13"x50" RA

4"ST

AHU

11

66"x18" SA

EXISTINGLOUVER

FLOOR MOUNTEDDUCT SUPPORTSBY MC

MECHANICALROOM

M524

2"D

1 1/2"HWR

1 1/2"HWS

EA

14x10 EA

10"x6" SA

PLENUM SHALLSIT ON BASERAIL EXTENSION

24"x86" OA PLENUM

3"F

4"D

MD

2

1

1

1

Level 553' - 0"

Level 664' - 3"

Level 5 Btm of Beam63' - 0"

A

M301

T

AHU

11

4" CWS/R TOAHU-11 CC

2" LPS TOAHU-11HUMIDIFIER

1"LPR

2 1

/2"H

WS

2 1

/2"H

WR

HWRP

11

4"S

T

4"D

2"D

2" CONDENSATEDRAIN OVER FD

18"x66" SA(BEYOND)

14"x10" RA

20"x80" SA

FACTORY 10-INCHBASE RAIL

3"L

PR

3"L

PR

8"L

PS

6"C

WS

6"C

WR

4"CWS

8" LPS DN6" CWR FROM BELOW6" CWS DN

EA

MECHANICALROOM

M524

2 1/2" HWSFROM BELOW2 1/2" HWR DN

6"F

Level 553' - 0"

Level 664' - 3"

Level 5 Btm of Beam63' - 0"

46"x14" RA

56"x16" RA

14"x46" RA

40"x16" EA14"x30" RA

16"x70" SA

2"LPS4"CWS

4"CWR

66"x12" RA

2 1/2"HWR

CAP EXISTINGRA DUCT ATWALL

EA

EA

EA

EA

EA

MECHANICALROOM

M524

E-1

250

8"x22" EA

1 1/2"HWR

1 1/2"HWS 6"HWR

6"HWS

Level 553' - 0"

Level 664' - 3"

Level 5 Btm of Beam63' - 0"

Level 777' - 3"

ROOF TOP90' - 3"

24"x

18"

EA

24"x18" EA (VR-2)

18"x18" EA

40"x

16"

EA

1 1/2"LPR

ABANDONEDEA RISERS

30"x14" RAEA

MECHANICALROOM

M524

TC

PA

NE

L B

YD

IV 2

3

PA

NE

LB

OA

RD

BY

DIV

26

DISCONNECT SWITCH.SEE E-SERIES SHEETS EXISTING

VERTICALBUS WAY

(BEYOND)

14"x24" EA

1' - 2"

2

2

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

9 P

M

505-106

M301

DPP

SECTIONS

JCS

01/11/2017

1/4" = 1'-0"A

MECHANICAL ROOM SECTION #1

1/4" = 1'-0"B

MECHANICAL ROOM SECTION #2

1/4" = 1'-0"C

MECHANICAL ROOM SECTION #3

1/4" = 1'-0"D

EXHAUST RISER SECTION

KEYED NOTES:

1 FLOOR OF OUTSIDE AIR PLENUM SHALL BE RATEDFOR 250 LBS MINIMUM.

2 MAINTAIN MAXIMUM CLEARANCE BETWEEN 14x24 EADUCT AND EXISTING BUS RISER TO ALLOW FORPOSSIBLE FUTURE INSTALLATION OF MAXIMUMALLOWABLE BUS PLUG. 14x24 EA DUCT SHALLTRANSITION BACK TO 24x18 AT UNDERSIDE OF SIXTHFLOOR SLAB.

#

1

1 01/20/17 ADDENDUM 1

Page 26: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

FIRST FLOOR

SECOND FLOOR

THIRD FLOOR

FOURTH FLOOR

FIFTH FLOOR

SIXTH FLOOR

SEVENTH FLOOR

MECHANICAL PENTHOUSE

AHU-79

EX 12" CWS/RRISERS IN MY100AELEC STOR

AHU-11

AHU-16

AHU-22

4" CWS/R TOSERVE AHU-69

4" CWS

4" CWR

6" CWS

6" CWR

6"

CW

S

6"

CW

R

6"

CW

S

6"

CW

R

6"

CW

S

6"

CW

R

6" CWR

6" CWS

8" CWR

8" CWS

10"

CW

R

10"

CW

S

10"

CW

R

10"

CW

S

10"

CW

R

10"

CW

S

4" CWS/R TOSERVE AH-11

4" CWS/R TAPS FORFUTURE CONNECTION

4" CWS/R TAPS FORFUTURE CONNECTION

ROOF

INSTALL SHUTOFF VALVES ABOVEEXISTING AHU-16 RUNOUTSDURING CHILLED WATER SYSTEMSHUTDOWN TO ALLOW VERTICALRISERS TO BE INSTALLEDWITHOUT SHUTTING DOWN ENTIRECHILLED WATER SYSTEM. VALVEINSTALLATION SHALL COINCIDEWITH 1ST FLOOR PIPING WORK.

INSTALL TAPS AND SHUTOFFVALVES FOR VERTICAL RISERSDURING CHILLED WATER SYSTEMSHUTDOWN TO ALLOW RISERS TOBE INSTALLED WITHOUT SHUTTINGDOWN ENTIRE CHILLED WATERSYSTEM. VALVE INSTALLATIONSHALL COINCIDE WITH 1ST FLOORPIPING WORK.

1

EX 10" CWS/R RISERS IN UTILITYCHASE IN M168A MECH RM,ADJACENT TO M168 JAN CLOSET

FIRST FLOOR

SECOND FLOOR

THIRD FLOOR

FOURTH FLOOR

FIFTH FLOOR

SIXTH FLOOR

10" HWS/R TOBASEMENT

AHU-11

4" CWS/R TOSERVE AHU-69

2-1/2" HWS

2-1/2" HWR

6"

HW

S

6"

HW

R

2-1/2" HWS/R TOSERVE AHU-11

EX 6" HWS/R

6" HWS

6" HWR

4" HWS/R TAPS FORFUTURE CONNECTION

4" HWS/R TAPS FORFUTURE CONNECTION

4" HWS/R TAPS FORFUTURE CONNECTION

4" HWS/R TAPS FORFUTURE CONNECTION

6" HWS/R TAPSTO SERVEFLOORS ABOVE.

2-1

/2"

HW

R

2-1

/2"

HW

S

6"

HW

S

6"

HW

R

4" HWS/R TAPS TO SERVEFUTURE FIFTH FLOORTERMINAL UNITS

2-1/2" HWS/R TO SERVEFIFTH FLOOR TERMINALHEATING COILS

1

NOTE THAT WORK OCCURS IN M148INSTRUCTIONAL LAB GROSSANATOMY. COORDINATE ACCESSWITH OWNER'S REPRESENTATIVE.

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:4

9 P

M

505-106

M401

DPP

HYDRONIC FLOW DIAGRAMS

JCS

01/11/2017

NOT TO SCALE1

CHILLED WATER FLOW DIAGRAM

NOT TO SCALE2

HEATING HOT WATER FLOW DIAGRAM

1

1 01/20/17 ADDENDUM 1

Page 27: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

AHU-11 SECTION VIEW11

AHU-11 PLAN VIEW10

FILTER INLET PLENUM WITH BACK INLET,

WITH 2" MERV 8 PREFILTER, 12" MERV 15

INTERMEDIATE FILTER, AND 18" WIDE

ACCESS DOOR.

PREHEAT COIL SECTION

24" ACCESS SECTION (DUAL 19" WIDE

ACCESS DOORS).

COMBINATION COOLING COIL AND

HUMIDIFIER SECTION (HUMIDIFIER

DIRECTLY AFTER COOLING COIL)

24" ACCESS SECTION (19" WIDE ACCESS

DOOR)

SUPPLY FAN SECTION. FAN ARRAY WITH

DUAL DIRECT DRIVE PLENUM FANS.

DISCHARGE PLENUM WITH FRONT

CONNECTION.

1

2

3

4

5

6

7

1 2 3 4 5 6 7

AHU-11 AIR

SCALE: NTS

COMPONENTS

HANDLING UNIT

SCALE: NTS

AP AP AP AP

6'-8"

16'-2" MAX LENGTH

10"

7'-4"

MA

X H

EIG

HT

BASE RAIL

PRESSURE INDEPENDENT 2-WAYMODULATING CONTROL VALVE

CHILLED WATERRETURN

AIRFLOW

STRAINER WITH BLOWOFFCONNECTION, 3/4" SHUTOFF VALVE,3/4" HOSE BIB CONNECTION AND CAP.

CHILLEDWATERSUPPLY

REDUCER (TYP)

MANUAL AIR VENT (TYP) AT HIGH POINTBETWEEN ISOLATION VALVE AND COIL(TYP) EACH COIL IN MULTI-COIL BANK

M

M

THERMOMETER (TYP)

UNION OF FLANGE (TYP)SEE "HYDRONIC PIPING" SPECFOR TYPE

SHUTOFF VALVE (TYP)SEE VALVE SPEC FOR TYPE

MANUAL AIR VENT (TYP)INSTALL AT HIGH POINTBETWEEN ISOLATIONVALVE AND COIL (TYP)

M

M

PRESSURE/TEMPERATURE PORT FORPRESSURE MEASUREMENT (TYPICAL FOREACH COIL). INSTALL AT SAME ELEVATION.PROVIDE EXTENSIONS ON TAPS SO ALL PTPORTS ARE EXTENDED THROUGH THICKNESSOF INSULATION. IF PROVIDED BY UNITMANUFACTURER ADDITIONAL P&T PORTS ARENOT REQUIRED.

3/4" COIL DRAIN VALVE, 3/4" HOSE BIBCONNECTION, AND CAP, AT EACH COILIN MULTIPLE BANKS. DRAIN SHALL BEEXTENDED TO EXTERIOR OF UNITCABINET (TYP).

P&T

P&T

P&T

P&T

PROVIDE CALIBRATED BALANCING VALVEIN CWR PIPING TO EACH COIL SECTION INMULTI-COIL BANK.

NOTES:

1. BRANCH PIPING SHALL TAP OFF THE TOP OF THE MAINS.

2. LOCATE SHUT-OFF VALVES AND UNIONS/FLANGES TO ALLOW FOR REMOVAL OFCOIL WITHOUT SHUTTING DOWN HYDRONIC SYSTEM.

3. PROVIDE VENT ON BOTH SUPPLY AND RETURN AT HIGH POINTS.

4. PROVIDE FLANGE OR UNION AT EACH CONNECTION TO EACH COIL (TYPICAL).

5. PROVIDE REDUCER AT COIL CONNECTION WHERE REQUIRED.

6. ALL VENT AND DRAINS SHALL BE LOCATED OUTSIDE OF AIR HANDLING UNITCABINET.

7. THIS DETAIL IS FOR ALL STACKED TWO-WAY COILS IN AIR HANDLING UNITS.

OFFSET PIPING TO CLEARCOIL PULL SPACE

CHECK VALVE

4"

4"

3"

3"

HOT WATER RETURN

UNION (TYP)

SHUTOFF VALVE (TYP)

HOT WATER SUPPLYREDUCER (TYP)

M

CHECK VALVE

THERMOMETER (TYP)

AIR HANDLING UNITPREHEAT COILS

M

INLINE RECIRCULATING PUMP(SEE DETAIL 6 THIS SHEET)

2-WAY MODULATING 0-10VDCPROPORTIONAL CONTROL VALVE

PROVIDE CALIBRATED BALANCING VALVE INHWR PIPING TO EACH COIL SECTION INMULTI-COIL BANK

NOTES:

1. BRANCH PIPING SHALL TAP OFF THE TOP OF THE MAINS.

2. LOCATE SHUT-OFF VALVES AND UNIONS/FLANGES TO ALLOW FOR REMOVAL OF COILWITHOUT SHUTTING DOWN HYDRONIC SYSTEM.

3. PROVIDE VENT ON BOTH SUPPLY AND RETURN AT HIGH POINTS.

4. PROVIDE FLANGE OR UNION AT EACH CONNECTION TO EACH COIL (TYPICAL).

5. PROVIDE REDUCER AT COIL CONNECTION WHERE REQUIRED.

6. ALL VENT AND DRAINS SHALL BE LOCATED OUTSIDE OF AIR HANDLING UNITCABINET.

7. THIS DETAIL IS FOR ALL STACKED TWO-WAY COILS IN AIR HANDLING UNITS.

STRAINER WITH BLOWOFFCONNECTION, 3/4" SHUTOFF VALVE,3/4" HOSE BIB CONNECTION AND CAP.

MANUAL AIR VENT (TYP) AT HIGH POINTBETWEEN ISOLATION VALVE AND COIL(TYP) EACH COIL IN MULTI-COIL BANK

MANUAL AIR VENT (TYP)INSTALL AT HIGH POINTBETWEEN ISOLATIONVALVE AND COIL (TYP)

PRESSURE/TEMPERATURE PORT FOR PRESSUREMEASUREMENT (TYPICAL FOR EACH COIL).INSTALL AT SAME ELEVATION. PROVIDEEXTENSIONS ON TAPS SO ALL PT PORTS AREEXTENDED THROUGH THICKNESS OF INSULATION.IF PROVIDED BY UNIT MANUFACTURERADDITIONAL P&T PORTS ARE NOT REQUIRED.

3/4" COIL DRAIN VALVE, 3/4" HOSE BIBCONNECTION, AND CAP, AT EACH COILIN MULTIPLE BANKS. DRAIN SHALL BEEXTENDED TO EXTERIOR OF UNITCABINET (TYP).

AUTOFLOWBALANCEVALVE

AIRFLOW

M

M

P&T

P&T

P&T

P&T

2-1/2"

2-1/2"

2"

2"

2-1/2"

NOTES

DISPERSION TUBEASSEMBLY

UNION OR FLANGE (TYP), SEESTEAM PIPING SPEC FOR TYPE

STRAINER WITH BLOWDOWN VALVE,NIPPLE, AND CAP (SEE NOTE 2)

LPS

SECURELY FASTEN DISPERSION TUBEACCORDING TO THEMANUFACTURER'S INSTRUCTIONS.

MODULATING CONTROL VALVE, 2-POSITION CONTROL VALVE, TRAP ANDSTRAINER SHALL BE PROVIDED BYTHE HUMIDIFIER MANUFACTURER.

TRAP - 3/4" INVERTED BUCKET TYPE.

PROVIDE HUMIDITY HIGH LIMIT ANDPRESSURE DIFFERENTIAL SWITCHESDOWNSTREAM FROM DISPERSIONTUBE.

BRANCH PIPE SHALL CONNECT TO TOPOF MAIN.

6" LONG DIRT LEG

SHUT-OFF VALVE (TYP)SEE SPEC FOR TYPE

LPR

MODULATING STEAMCONTROL VALVE (TYP)(SEE NOTE 2)

STEAM TRAP(NOTES 2 AND 3)

SEE NOTE 5

CHECK VALVE (TYP)

1.

2.

3.

4.

5.

AIR FLOW

STEAM SUPPLY TOHEAT EXCHANGER

STEAM SUPPLY TOHUMIDIFIER GRID

2-POSITION ISOLATIONVALVE (SEE NOTE 2)

M

P&T

P&T

3/4" COIL DRAIN VALVE,3/4" HOSE BIBCONNECTION AND CAP AT EACH COIL AND EACHMANUFACTURER PROVIDED DRAIN.

OFFSET PIPING TO CLEARCOIL PULL SPACE ASREQUIRED.

HYDRONIC COIL

MANUAL AIR VENT (TYP)

REDUCER (TYP)

HYDRONIC SUPPLY MAIN

SHUTOFF VALVE (TYP)SEE VALVE SPEC FOR TYPE

UNION OF FLANGE (TYP)SEE "HYDRONIC PIPING" SPECFOR TYPE

PROVIDE FLANGE, OR UNION AT EACHCONNECTION TO COIL (TYP)

AIRFLOW

HYDRONIC RETURN MAIN

SEE NOTE 1

M

PRESSURE INDEPENDENT 2-WAY MODULATING CONTROLVALVE

STRAINER WITH BLOWOFFCONNECTION, 3/4" SHUTOFF VALVE,3/4" HOSE BIB CONNECTION AND CAP.

PRESSURE/TEMPERATURE PORT FOR PRESSUREMEASUREMENT. INSTALL AT SAME ELEVATION. PROVIDEEXTENSIONS ON TAPS SO ALL PT PORTS ARE EXTENDEDTHROUGH THICKNESS OF INSULATION. IF PROVIDED BYUNIT MANUFACTURER ADDITIONAL P&T PORTS ARE NOTREQUIRED.

NOTE:

1. BRANCH PIPES SHALL TAP OFF THE TOP OF MAINS.

2. DETAIL APPLIES TO AIR TERMINAL UNIT HEATING COILS AND DUCT MOUNTEDREHEAT COILS (RHC).

STRAINER WITHBLOW-DOWNVALVE

DRIP LEG 6"MIN

TOCONDENSATERETURN PIPE

SHUT-OFF VALVE

UNION

CHECK VALVE

12" MINIMUM

STEAM MAIN

T

3/4" INVERTED BUCKETSTEAM TRAP

NOTES:

1. SEE PLAN FOR PIPE SIZE.2. INDEPENDENTLY SUPPORT PUMP AND PIPING.

3/8" BALL VALVE (TYP.) -USE TAPS ON PUMPVOLUTE, IF AVAILABLE

SHUT-OFFVALVE (TYPICAL)

PRESSUREGAUGE

INLINEHORIZONTALHOTWATERRECIRCULATINGPUMP

HANGERS (TYP)

VIBRATIONISOLATOR (TYP)

MANUAL AIR VENT

THREADED OR WELDEDOUTLET FITTING (TYP)

3/4" HOSE END DRAIN VALVE AND CAP

INSTALL VENT AT ALL PIPING HIGH

POINTS AND AT TOP OF EVERY HYDRONIC

RISER. REFER TO HYDRONIC FLOW

DIAGRAMS.

INSTALL DRAIN AT ALL PIPING

LOW POINTS

TYPICAL PIPE MAINOR BRANCH

3/4" BALL VALVE

BOTTOM OF AHUCABINET.

PIPE FULL SIZE OF AIRHANDLING UNIT DRAINCONNECTION

AHU BASE RAIL

1 REMOVABLE CAP

1 REMOVABLE CAP

4 FLOW

3

2.5-INCH

5-INCH

NOTE:

2

4

3

1 LOCATE TRAPS SO AS TO BE ACCESSIBLE FOR CLEANING.

ROUTE TO NEAREST SANITARY (FLOOR) DRAIN, SLOPE AT 1/8" PER FOOT.

2

MANUFACTURERAIRFLOW SENSOR

EXTERNALLY INSULATEDTERMINAL INLET DUCT, SIZEAS INDICATED ON VAV BOXSCHEDULE

3.0 MINIMUM

INLET DIAMETERS

36" DEEP BY 30" WIDECLEARANCE ATSIDE OF DIGITAL CONTROLPANEL.

MA

IN S

UP

PLY

AIR

DU

CT

1SUSPEND FROM STRUCTURE IN ACCORDANCE WITH MANUFACTURERS

RECOMMENDATIONS. HANGERS & BRACING SHALL NOT OBSTRUCT

ACCESS PANELS AND/OR SERVICE SPACE. DO NOT OBSTRUCT ACCESS

PANELS AND/OR SERVICE SPACE. REFER TO MANUFACTURER'S

RECOMMENDED UNIT INSTALLATION MANUAL.

INSTALL TERMINAL UNIT PLUMB AND LEVEL, WITH SERVICE SPACE FOR

CONTROLS.

WHERE POSSIBLE PROVIDE 4'-0" OF DUCTWORK DOWNSTREAM OF VAV

BOX PRIOR TO FIRST TAP.

MANUFACTURER PROVIDED HEATING COIL. REFER TO DETAIL 4 ONSHEET M501 FOR PIPING. CONTRACTOR SHALL COORDINATERIGHT/LEFT HAND HOT WATER COIL CONNECTION WITH EXISTINGFIELD CONDITIONS PRIOR TO ORDERING UNITS. (REFER TOSCHEDULE SHEETS FOR UNITS REQUIRING AUXILIARY HEATINGCOILS.) RETURN BENDS OF COIL MUST BE INSULATED.

MANUFACTURER PROVIDED ACCESSDOOR SECTION WITH SLIP AND DRIVE CONNECTIONS.

1

DIGITALCONTROLPANEL

2

1

NOTES:

2

18X18 ACCESS PANEL IN SUPPLY AIR DUCTWORK

3

3

EXTERNALLY WRAPPED SUPPLY AIRDUCT. SIZE AS INDICATED ON PLANS.INSULATION SHALL FULLY COVER/WRAPREHEAT COIL TUBE BENDS. SEALINSULATION TO UNIT CASING.

PROVIDE ADDITIONAL INLET DUCT2" LARGER THAN TERMINAL UNITINLET SIZE

AIR

FLO

W

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

0 P

M

505-106

M501

DPP

DETAILS

JCS

01/11/2017

NTS1

AIR HANDLING UNIT COOLING COIL WITH2-WAY VALVE DETAIL

NTS2

AIR HANDLING UNIT PRE-HEAT COIL PIPINGDETAIL

NTS3

AHU HUMIDIFIER DETAIL

NTS4

COIL CONNECTION WITH 2-WAY (PIC) VALVEDETAIL

NTS6

TYPICAL STEAM CONDENSATE DRIP TRAPASSEMBLY DETAIL

NTS7

INLINE RECIRCULATING PUMP

NTS5

HVAC DRAIN AND VENT DETAIL

NTS8

CONDENSATE DRAIN TRAP

NTS9

SUPPLY AIR TERMINAL UNIT INSTALLATION

NOTE: UNIT SHALL BE FURNISHED WITH MULTIPLESHIPPING SPLITS SIZED TO ALLOW UNIT TO BEBROUGHT INTO BUILDING THROUGH EXISTINGSERVICE ELEVATOR. CONTRACTOR SHALL FIELDVERIFY EXISTING CONDITIONS PRIOR TO SUBMITTINGSHOP DRAWINGS. ELEVATOR DIMENSIONS ARE 83

INCHES TALL BY 84 INCHES DEEP BY 43 INCHES WIDE.IF ANY COMPONENT REQUIRES DISASSEMBLY TOMOVE INTO BUILDING, UNIT MANUFACTURER SHALLWITNESS DISASSEMBLY AND REASSEMBLY TOMAINTAIN MANUFACTURER'S WARRANTY ANDSCHEDULED PERFORMANCE.

1

1

1 01/20/17 ADDENDUM 1

Page 28: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

0 P

M

505-106

M601

DPP

SCHEDULES

JCS

01/11/2017

AIR HANDLING UNIT SCHEDULE CONTINUED

CHILLED WATER COIL

HUMIDIFIERTAG

FILTERS MAX SOUND POWER RATING (RADIATED / DISCHARGE / INLET) - SEE NOTE 2 ELECTRICAL DATA - SEE NOTE 1

NOTES

CAPACITY (MBH)

MAX FACE VEL(FPM)

EAT LAT

WATER FLOW(GPM) EWT (°F) LWT (F°) ROWS

MAX PD PRE- INTERMEDIATE OCTAVE BAND (HZ)

HP V/PH/HZTOTAL SENS. DB (°F) WB (°F) DB (F°) WB (F°) AIR (IN WC) WATER (FT) TYPEDESIGN APD

(IN WC) TYPEDESIGN APD

(IN WC) 63 125 250 500 1000 2000 4000 8000

1416.7 725.8 525 95 78 53 52.5 202.4 46 60 8 2.2 15 H-11 2" MERV 8 0.5 12" MERV 15 1.0 81 / 86 / 81 75 / 80 / 75 72 / 80 / 78 77 / 85 / 85 67 / 83 / 71 57 / 79 / 66 47 / 78 / 59 51 / 71 / 51 (2) 15 HP 480 / 3 / 60 3, 4, 6, 7

2. DAMPER SHALL INCLUDE VERTICAL BLADES AND BOTTOM ACTUATOR.

1. ACTUATOR SHALL BE FURNISHED AND INSTALLED AS WORK OF 230900.

NOTES:

MOTORIZED DAMPER SCHEDULE

PLAN MARKMFR. MODEL LOCATION SERVICE

BLADECONFIGURATION

CONTROLACTION FAIL POSITION SIZE W x H MOUNTING NOTES

MD 1 GREENHECK VCD-23 CORR M517 HOT DECK OPPOSED BLADE MODULATING OPEN 60x10 DUCT 1, 2

MD 2 GREENHECK VCD-23 MECH M524 OUTSIDE AIR OPPOSED BLADE MODULATING OPEN 68x60 DUCT 1

MD 3 GREENHECK VCD-23 MECH M524 OUTSIDE AIR OPPOSED BLADE MODULATING OPEN 48x60 DUCT 1

2. PROVIDE FLANGED CONNECTIONS.

1. DIMENSIONS CORRESPOND TO FINNED AREA.

NOTES:

DUCT MOUNTED HEATING COIL SCHEDULE

PLAN MARK MFR. TYPE LOCATION SERVICE COIL SIZE APD (IN WC)

HOT WATER HEATING

NOTESMBH EAT (F) EWT (F) LWT (F) FLOW (GPM) MAX WPD (FT)

RHC 5-1 USA COIL & AIR DUCT-MOUNTED MECH M524 HOT DECK 56x24 0.25 382.7 55 180 140 19.1 5 1, 2

HUMIDIFIER SCHEDULE

PLAN MARK MFR. MODEL LOCATION

OUTPUTCAPACITY(LBS/HR)

EAT LATAIRFLOW

(CFM)

STEAM SUPPLY

NOTESDB RH DB RH LOAD PRESS (PSIG)

H 11 DRISTEEM ULTRA-SORB MODEL XV AHU-11 299.3 53 5 55 54 16000 299.3 10 1, 2

1. SEE EQUIPMENT DATA SCHEDULE(S) FOR ELECTRICAL INFORMATION.

NOTES:

PUMP SCHEDULE

PLAN MARK MFR. MODEL TYPE LOCATION SERVICEWATER FLOW

(GPM) TDH (FT)

MIN INLET /OUTLET SIZES

(IN)MAX NPSHREQD (FT) MIN EFF (%)

MOTOR SPEED(RPM)

ELECTRICAL DATA

NOTESHP V/PH/HZ

HWRP 11 BELL & GOSSETT 2.5x2.5x7B INLINE MECH M524 AHU-11 PREHEAT COIL 56.0 25 2.5 / 2.5 4.4 57 1750 1.0 480/3/60

7. UNIT SHALL BE FURNISHED WITH FACTORY HUMIDIFIER GRID. SEE HUMIDIFIER SCHEDULE FOR PERFORMANCE REQUIREMENTS.

IF ANY COMPONENT REQUIRES DISASSEMBLY TO MOVE INTO BUILDING, UNIT MANUFACTURER SHALL WITNESS DISASSEMBLY AND REASSEMBLY TO MAINTAIN MANUFACTURER'S WARRANTY AND SCHEDULED PERFORMANCE.

6. UNIT SHALL BE FURNISHED WITH MULTIPLE SHIPPING SPLITS SIZED TO ALLOW UNIT TO BE BROUGHT INTO BUILDING THROUGH EXISTING SERVICE ELEVATOR. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING SHOP DRAWINGS. ELEVATOR DIMENSIONS ARE 83 INCHES TALL BY 84 INCHES DEEP BY 43 INCHES WIDE.

5. MAXIMUM UNIT DIMENSIONS ARE AS FOLLOWS: WIDTH: 80 INCHES; LENGTH: 194 INCHES; HEIGHT: 88" INCLUDING 10" BASE RAIL.

4. PROVIDE WITH MINIMUM 10" TALL BASE RAIL.

3. PROVIDE WITH INVERTER-READY OR INVERTER-DUTY MOTOR FOR VARIABLE SPEED OPERATION. REFER TO DIV 23 MOTOR SPECIFICATION FOR MOTOR REQUIREMENTS.

2. SOUND POWER LEVEL RATINGS SHOWN IN DECIBELS, REFER TO 10(-12) WATTS CALCULATED PER AMCA STANDARD 301.

1. SEE EQUIPMENT DATA SCHEDULE FOR ELECTRICAL INFORMATION.

NOTES:

AIR HANDLING UNIT SCHEDULE

PLAN MARK MFR. MODEL TYPE LOCATION SERVICE MIN. OA (CFM)MAX SIZE(LxWxH)

MAXOPERATING

WEIGHT (LBS)

SUPPLY FAN HOT WATER PREHEAT COIL

TOTALAIRFLOW

(CFM)

STATIC PRESSURE

TYPE DRIVEMAX WHEEL

SIZE (IN)MAX FAN

SPEED (RPM)MAX MOTORSPEED (RPM)

CAPACITY(MBH)

MAX FACE VEL(FPM) EAT (°F) LAT

WATER FLOW(GPM) EWT (°F) LWT ROWS

MAX PD

TSP (IN WC) ESP (IN WC) AIR (IN WC) WATER (FT)

AHU 11 DAIKIN VISION INDOORMODULAR

MECH M524 5TH FLOOREAST

16000 SEE NOTE 5 6200 16000 6.6 2.5 PLENUM (1x2FAN ARRAY)

DIRECT 18.25 3150 3500 1123.2 550 0 65 56.2 180 140 2 0.2 5

3. PROVIDE WITH OPTIONAL BOTTOM ACCESS DOOR PER THE SPECFICATIONS.

2. PROVIDE THE NUMBER OF COIL ROWS AS REQUIRED TO MEET SCHEDULED PERFORMANCE AND STILL FALL WITHIN REHEAT COIL PRESSURE DROP LIMITATION.

1. MAX TOTAL PRESSURE DROP SHALL INCLUDE BOX AND REHEAT COIL (WHERE APPLICABLE).

NOTES:

AIR TERMINAL UNIT SCHEDULE

PLAN MARK MFR. MODEL TYPE SERVICE LOCATIONINLET DUCT

SIZE (IN RND)

PRIMARY AIRFLOW (CFM) DESIGN INLETSTATIC PRESSURE

(IN WC)

MAXPRESSURE

DROP (IN WC)OUTLET DUCTSIZE WxD (IN)

AUXILIARY HOT WATER HEATNG COIL MAX NC LEVEL @ MAX CFM

NOTESMAX MINAIRFLOW

(CFM)CAPACITY

(MBH) EAT (°F) LAT (°F) EWT (°F) FLOW (GPM) ROWSMAX WPD (FT

HD)MAX APD(IN

WC)CONTROL

VALVE DISCHARGE RADIATED

VAV 550 TITUS DESV PRESSURE INDEPENDENT M531 RESEARCH LAB M531 RESEARCH LAB 8 600 600 1.5 0.75 12x10 600 25.9 55 95 180 2.6 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 551 TITUS DESV PRESSURE INDEPENDENT M533 RESEARCH OFFICE M533 RESEARCH OFFICE 6 310 310 1.5 0.75 12x8 310 13.4 55 95 180 1.3 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 552 TITUS DESV PRESSURE INDEPENDENT M524 MECHANICAL ROOM M524 MECHANICAL ROOM 6 250 250 1.5 0.75 12x8 250 8.1 55 85 180 0.8 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 553 TITUS DESV PRESSURE INDEPENDENT M530 RESEARCH OFFICE M530 RESEARCH OFFICE 6 150 150 1.5 0.75 12x8 150 6.5 55 95 180 0.6 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 554 TITUS DESV PRESSURE INDEPENDENT M529 RESEARCH LAB M529 RESEARCH LAB 14 1000 1000 1.5 0.75 20x17 1/2 1000 43.2 55 95 180 4.3 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 555 TITUS DESV PRESSURE INDEPENDENT M539 CORRIDOR M539 CORRIDOR 10 500 500 1.5 0.75 14x12 1/2 500 16.2 55 85 180 1.6 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 556 TITUS DESV PRESSURE INDEPENDENT M528 RESEARCH LAB M528 RESEARCH LAB 8 400 400 1.5 0.75 12x10 400 17.3 55 95 180 1.7 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 557 TITUS DESV PRESSURE INDEPENDENT M526 RESEARCH OFFICE M526 RESEARCH OFFICE 8 750 500 1.5 0.75 12x10 500 21.6 55 95 180 2.2 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

VAV 558 TITUS DESV PRESSURE INDEPENDENT M539 CORRIDOR M539 CORRIDOR 8 400 400 1.5 0.75 12x10 400 13.0 55 85 180 1.3 SEE NOTE 2 2.0 0.25 2-WAY 30 30 1, 3

NOTES:

1. MAXIMUM ACCEPTABLE ABSORPTION DISTANCE SHALL BE 12-INCHES.2. PROVIDE WITH OPTIONAL INLET STRAINER, 2-POSITION SHUTOFF VALVE, MODULATED STEAM CONTROL VALVE, STEAM TRAP, AND FLOAT SWITCH. VALVES AND FLOAT SWITCH

SHALL BE CAPABLE OF BEING CONTROLLED VIA EMCS.

2. LOUVERED AREA SHALL BE MINIMUM 18x18.

1. PROVIDE WITH BACKPAN WITH SQUARE TO ROUND ADAPTER TO ACCOMMODATE SCHEDULED NECK SIZE.

NOTES:

AIR DEVICE SCHEDULE

PLAN MARK MFR. MODEL TYPE LOCATION NECK SIZE (IN) FACE SIZE (IN x IN) MATERIAL FINISHMAX TPD (IN

WC) MAX NOISE (NC)

MAX CFM @LISTED

CONDITIONSMIN THROW(FT) 50 FPM NOTES

S-1 TITUS 300RL LOUVERED FACE DUCT 12x8 14x10 STEEL WHITE 0.1 30 250 30

S-2 TITUS TMRA ADJUSTABLE ROUND EXPOSED 12 27 INCH RND STEEL WHITE 0.1 30 350 10

S-3 TITUS TDC SQUARE PLAQUE CEILING 8 24x24 STEEL WHITE 0.1 30 300 15 1, 2

S-4 TITUS TDC SQUARE PLAQUE CEILING 12 24x24 STEEL WHITE 0.1 30 500 18 1, 2

E-1 TITUS 350RL LOUVERED FACE DUCT 22x8 24x10 STEEL WHITE 0.1 30 600 -

E-2 TITUS 350RL LOUVERED FACE CEILING 8 24x24 STEEL WHITE 0.1 30 190 - 1

E-3 TITUS 350RL LOUVERED FACE CEILING 12 24x24 STEEL WHITE 0.1 30 430 - 1

E-4 TITUS 350RL LOUVERED FACE CEILING 14 24x24 STEEL WHITE 0.1 30 630 - 1

CONTROL VALVE SCHEDULE

NOTES:1. REFER TO APPROPRIATE SCHEDULE FOR FLOW INFORMATION2. MAXIMUM PRESSURE DROP AT FULL OPEN POSITION3. PRESSURE INDEPENDENT 2-WAY MODULATING CONTROL VALVE. SEE SPEC 230900.4. VALVE SHALL FAIL NORMALLY OPEN.5. VALVE SHALL FAIL NORMALLY CLOSED.6. CONTROL VALVE FLOW RATE SHALL BE ADJUSTED TO MATCH EQUIPMENT SHOP DRAWING SUBMITTAL VALUES.

UNIT SERVED SERVICE MAX PRESSURE DROP(PSIG) SEE NOTE 2

MAX FLOW (GPM/PPH)

CLOSE-OFFPRESSURE (PSI)

NOTES:

AHU-11

AHU-11

RHC (ALL)

VAV (ALL)

CHILLED WATER

HOT WATER

HOT WATER

HOT WATER

5.0

5.0

5.0

5.0

SEE NOTE 1

SEE NOTE 1

SEE NOTE 1

SEE NOTE 1

SEE SPEC

SEE SPEC

SEE SPEC

SEE SPEC

3, 5, 6

3, 4, 6

3, 5, 6

3, 4, 6

1

1

1 01/20/17 ADDENDUM 1

Page 29: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

SEQUENCES OF OPERATION

GENERAL NOTES:1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONTROL POINT NUMBERS FOR CONTROL POINTS INDICATED ON THESE DRAWINGS.

GENERAL:

THE CONTRACTOR SHALL SUBMIT ENGINEERED CONTROL DRAWINGS, WIRING DIAGRAMS, EQUIPMENT SCHEDULES, ETC., AS

REQUIRED FOR A COMPLETE CONTROL SYSTEM. THE CONTRACTOR WILL BE EXPECTED TO WORK OUT THE DETAILS OF

CONTROLLER ACTION, CONTROL LOOP TUNING, NORMALLY OPEN/NORMALLY CLOSED CONNECTIONS, EXACT EQUIPMENT

REQUIREMENTS, ETC., TO PROVIDE A WORKING CONTROL SYSTEM TO ACHIEVE THE SEQUENCES OF OPERATION BELOW. THE

WRITTEN SEQUENCE OF OPERATION SHALL BE THE CRITERION USED TO JUDGE THE FINAL PERFORMANCE OF THE CONTROL

SYSTEM. ALL FUNCTIONS IN THE SEQUENCE WILL BE REQUIRED EVEN IF THE REQUIRED EQUIPMENT AND CONNECTIONS ARE

NOT DEPICTED ON THESE DRAWINGS.

THE CONTRACTOR SHALL COORDINATE THE LOCATIONS OF BUILDING CONTROL PANELS WITH THE OWNER'S

REPRESENTATIVE.

THE UNIVERSITY OF MISSOURI - COLUMBIA UTILIZES JOHNSON CONTROLS EQUIPMENT FOR THEIR CAMPUS ENERGY

MANAGEMENT CONTROL SYSTEM (EMCS). NEW DDC CONTROL SYSTEM SHALL FULLY INTERFACE WITH THE CAMPUS JOHNSON

CONTROLS METASYS SYSTEM.

THE FOLLOWING RESPONSIBILITIES EXIST FOR THIS PROJECT REGARDING CONNECTION TO THE CAMPUS ENERGY

MANAGEMENT CONTROL SYSTEM. THE CONTRACTOR IS RESPONSIBLE FOR ALL OTHER CONTROL ELEMENTS REQUIRED AS A

PART OF THESE SEQUENCES OF OPERATION, EXCEPT AS SPECIFICALLY INDICATED BELOW:

OWNER:

1. THE OWNER WILL PROVIDE THE JOHNSON CONTROLS METASYS PANEL(S) THAT IS REQUIRED FOR THE POINTS INDICATED.

2. THE OWNER WILL PROVIDE ALL PROGRAMMING OF THE NEW METASYS PANEL(S).

3. THE OWNER WILL ADDRESS START-UP OF THE NEW METASYS PANEL(S) AS IT RELATES TO THE NEW CONTROL AND

MONITORING POINTS AND WILL TERMINATE WIRING WITHIN THE METASYS PANEL(S).

NOTE: THE OWNER'S RESPONSIBILITIES ARE LIMITED TO WORK ASSOCIATED WITH THE METASYS PANELS ONLY, AND ONLY AS

INDICATED ABOVE, AND SHALL NOT EXTEND BEYOND THAT.

CONTRACTOR:

1. THE CONTRACTOR SHALL MOUNT THE METASYS PANEL(S) FURNISHED BY THE OWNER.

2. THE CONTRACTOR SHALL ROUTE ALL WIRING TO THE METASYS PANEL(S) FOR THE FIELD MOUNTED SENSORS/EQUIPMENT

AS REQUIRED TO ACHIEVE THE SEQUENCE OF OPERATION. NOTE THAT TERMINATION OF THE WIRING IS BY THE OWNER AT

THE METASYS PANEL.

3. THE CONTRACTOR SHALL PROVIDE POWER TO THE METASYS CONTROL PANEL(S) AND CONTROL SENSORS/METERS

REQUIRING SAME.

CENTRAL STATION AIR HANDLING UNIT AHU-11 AND RECIRCULATING PUMP HWRP-11:

THE AIR HANDLING UNIT SHALL BE UNDER THE CONTROL OF THE ENERGY MANAGEMENT CONTROL SYSTEM (EMCS). VARIABLE

SPEED FANS (2 TOTAL) SHALL BE UTILIZED TO SUPPLY 100% OUTSIDE AIR TO THE BUILDING SPACES SERVED BY THE AIR

HANDLING UNIT. UNIT SUPPLY FANS SHALL OPERATE ONLY WHEN THE NORMALLY CLOSED OUTSIDE AIR DAMPER IS PROVEN

OPEN VIA END SWITCH.

SUPPLY FAN CONTROL: UPON RECEIVING A SIGNAL FROM THE EMCS TO BEGIN OPERATION, THE SUPPLY FANS IN THE AIR

HANDLING UNIT SHALL BE ACTIVATED. THE FANS SHALL NOT START UNLESS THE OUTDOOR AIR DAMPER END SWITCHES ON

THE DAMPERS HAVE BEEN PROVEN OPEN (HARDWIRED INTERLOCK). THE EMCS SHALL THEN READ THE STATIC PRESSURE IN

THE COLD DECK SUPPLY DUCTWORK VIA TWO (2) STATIC PRESSURE SENSORS, COMPARING THE SIGNAL TO THE

PREDETERMINED SETPOINT (INITIALLY 1.5 IN W.C., ADJUSTABLE). THE SUPPLY FAN VARIABLE FREQUENCY DRIVE SHALL VARY

THE SPEED OF THE SUPPLY FAN MOTORS IN UNISON TO MAINTAIN THE COLD DECK SUPPLY AIR STATIC PRESSURE SETPOINT.

UPON RECEIVING A SIGNAL TO START THE UNIT, THE COLD DECK DAMPERS SHALL FULLY OPEN AND THE HOT DECK DAMPERS

SHALL OPEN TO 50% UNTIL THE SUPPLY FANS HAVE REACHED THEIR COMMANDED SPEED. ONCE THE FANS HAVE REACHED

THEIR COMMANDED SPEED, THE COLD AND HOT DECK DAMPERS SHALL BE FULLY CONTROLLED.

NOTE: AN UPPER LIMIT SPEED SETPOINT SHALL BE ASSIGNED TO THE SUPPLY FAN VFD TO LIMIT SUPPLY AIRFLOW. SET UPPER

LIMIT AT 12,000 CFM (ADJ). UPPER LIMIT SHALL REMAIN SET UNTIL AHU-11 SERVICE AREA IS CONVERTED TO VARIABLE AIR

VOLUME OPERATION IN THE FUTURE.

HOT DECK DAMPER CONTROL: HOT DECK DAMPERS SHALL MODULATE TO MAINTAIN THE HOT DECK STATIC PRESSURE

SETPOINT ESTABLISHED DURING TESTING AND BALANCING.

COLD DECK DAMPER CONTROL: IF THE HOT DECK DAMPER IS FULLY OPEN AND THE HOT DECK SUPPLY DUCT STATIC

PRESSURE IS LESS THAN SETPOINT, THE VARIABLE FREQUENCY DRIVE SHALL VARY THE SPEED OF THE SUPPLY FAN MOTORS

IN UNISON TO MAINTAIN THE HOT DECK STATIC PRESSURE SETPOINT AND THE COLD DECK DAMPER SHALL MODULATE TO

MAINTAIN THE COLD DECK SUPPLY DUCT STATIC PRESSURE SETPOINT.

PREHEAT COIL CONTROL: WHEN OUTSIDE AIR TEMPERATURE (OA-T) DROPS BELOW 53 DEGREES F, THE EMCS SHALL

MODULATE THE PRE-HEATING COIL CONTROL VALVE (PHT-O) TO MAINTAIN SUPPLY AIR TEMPERATURE SETPOINT (53 DEGREES

F, ADJUSTABLE). WHEN OUTSIDE AIR TEMPERATURE DROPS BELOW 40 DEGREES F, THE EMCS SHALL ACTIVATE THE PREHEAT

COIL RECIRC PUMP (HWRP-11), AND IT SHALL RUN AT CONSTANT SPEED UNTIL OUTSIDE AIR TEMPERATURE RISES ABOVE 40

DEGREES.

COOLING COIL CONTROL: WHEN OUTSIDE AIR TEMPERATURE (OA-T) IS ABOVE 50 DEGREES F, THE EMCS SHALL MONITOR THE

SUPPLY AIR TEMPERATURE (SA-T) AND MODULATE THE COOLING COIL CONTROL VALVE (CLG-VLV) AS REQUIRED TO MAINTAIN

SUPPLY AIR TEMPERATURE SETPOINT (53 DEGREES F, ADJUSTABLE).

HUMIDIFIER CONTROL: PROVIDE DUCT-MOUNTED HUMIDITY SENSOR IN SUPPLY AIR DUCTWORK AS SHOWN ON AHU-11

CONTROL DIAGRAM. MODULATE HUMIDIFIER OUTPUT TO MAINTAIN WINTER SUPPLY AIR DUCT HUMIDITY SETPOINT (55% RH,

ADJUSTABLE) TO ACHIEVE 70 DEG-F / 30% RH IN THE SPACE. PROVIDE HIGH-LIMIT SENSOR IN SUPPLY AIR DUCTWORK TO LIMIT

SUPPLY AIR HUMIDITY TO NOT MORE THAN 80% RH (ADJUSTABLE).

A NORMALLY CLOSED TWO-POSITION CONTROL VALVE SHALL BE PROVIDED UPSTREAM OF THE HUMIDIFIER. UPON CALL FOR

HUMIDITY THE TWO-POSITION CONTROL VALVE SHALL OPEN, ALLOWING STEAM TO FLOW TO HUMIDIFIER. THE VALVE SHALL

CLOSE WHEN THE HUMIDITY LEVEL IS WITHIN SETPOINT LIMITS. VALVE SHALL BE LOCKED OUT WHEN OUTSIDE AIR

TEMPERATURE IS ABOVE 60 F (ADJUSTABLE).

THE HUMIDIFIER HIGH LIMIT SWITCH SHALL BE HARD PIPED WITH THE CONTROL SIGNAL SERVING THE HUMIDIFIER CONTROL

VALVE. WHEN THE HIGH LIMIT SWITCH TRIPS THE SIGNAL TO THE HUMIDIFIER SHALL BE INTERRUPTED AUTOMATICALLY

STOPPING HUMIDIFICATION.

A FACTORY FLOAT SWITCH SHALL BE PROVIDED IN THE HUMIDIFIER HEADER. IN THE EVENT OF A FLOODED HEADER, THE

FLOAT SWITCH SHALL OPEN AND THE MODULATING STEAM VALVE SHALL CLOSE AND AN ALARM SHALL BE ANNUNCIATED AT

THE OPERATOR'S WORKSTATION.

ALARM AT THE EMCS UPON SUPPLY HUMIDITY OUT-OF-LIMIT (INITIALLY BELOW 25% RH, ADJUSTABLE) .

ALARM AT THE EMCS IF SUPPLY AIR HUMIDITY REACHES 85% RH (ADJUSTABLE).

SAFETIES: THE FOLLOWING DEVICES SHALL BE HARDWIRED TO STOP THE SUPPLY FAN WHEN ACTIVATED, AND SHALL

REQUIRE A MANUAL RESET AT THE DEVICE FOR A RETURN TO NORMAL OPERATION.

TEMPERATURE LOW LIMIT (FREEZE STAT)

DUCT-MOUNTED SMOKE DETECTOR (FURNISHED AND INSTALLED AS WORK OF DIVISION 26)

HIGH STATIC ALARM

LOW STATIC ALARM

WHEN ANY OF THE ABOVE SAFETY DEVICES ARE TRIPPED, THE HARDWIRED SAFETY CIRCUIT SHALL STOP THE SUPPLY FAN

AND CLOSE THE OUTSIDE AIR DAMPER.

VAV TERMINAL UNITS:

VAV TERMINAL UNITS SHALL BE UNDER THE CONTROL OF THE EMCS. REFER TO SHEET M702 FOR SPECIFIC RESPONSIBILITIES

OF THE OWNER AND CONTRACTOR REGARDING INSTALLATION OF CONTROLS FOR THESE UNITS. VAV TERMINAL UNITS SHALL

UTILIZE DDC MICROPROCESSOR BASED LOGIC TO ACHIEVE ALL CONTROL FUNCTIONS.

COOLING MODE: VAV TERMINAL UNITS SHALL OPERATE AS CONSTANT VOLUME UNITS AND SHALL CONTINUOUSLY MODULATE

THE AIR DAMPER POSITION TO MAINTAIN THE AIRFLOW NOTED ON THE SCHEDULE.

HEATING MODE: WHEN SPACE TEMPERATURE IS BELOW SETPOINT, THE VAV TERMINAL UNIT CONTROLLER SHALL MODULATE

THE HEATING HOT WATER CONTROL VALVE TO MAINTAIN SPACE TEMPERATURE SETPOINT (72 DEGRESS F, ADJUSTABLE).

REHEAT COIL (RHC 5-1 AND 5-2):

THE EMCS SHALL MODULATE THE HEATING COIL CONTROL VALVE TO MAINTAIN HOT DECK SUPPLY AIR TEMPERATURE

SETPOINT (90 DEGREES F, ADJUSTABLE)..

RCT

24 VAC CONTROL RELAYCURRENT TRANSFORMER(SWITCH)

(SEE SPECS):

DEVICESKEEP ALL LOW VOLTAGE CONTROL WIRING (UNDER 25V) AND LOW VOLTAGE

POWER WIRING (OVER 25V) SEPARATED. (RUN IN SEPARATE CONDUIT.)

GET POWER FOR 24V TRANSFORMER FROM LINE SIDE OF MOTOR STARTER OR

VFD DISCONNECT. DO NOT POWER EXTERNAL DEVICES WITH VFD OR STARTER

CONTROL POWER.

PROVIDE RELAYS WITH MULTIPLE CONTACTS AS REQUIRED.

1.

2.

3.

GENERAL NOTES:

100% OA WITH VFD

METASYS(SF-SC)

ES CONTACTS ON R1

CONTACTS ON R3

METASYS(SF-S)

METASYS(LT-A)

METASYS(HS-A)

FREEZESTAT AUX

CONTACTS

CONTACTS R4

ST-CC

IV-CC

F-CC

SF VFD

METASYS(SF-C)

SUPPLYFAN CT R3

STATUSRELAY

R2 ST/SPRELAY

DMPRELAY

R1

HTGVALVERELAY

FA

CONTACTS R5

FRZSTA

T

24 VAC

R4 HSRELAY

HIGHSTATICSWITCH

(IF REQUIRED)

ON R3CONTACTSRESET

RESTART

S1 ON R2

BYPASS SIDE OFAUX CONTACTS ON

VFD I O B SWITCH

2

CONTACTS

1

TD

3

CONTACTS ON R2

117

SF

-S-2

VFD

M

119

HWR

HWS

NC

LT

-A

SMK

112

PH

T-O

M

123118

PH

P-S

PH

P-C

111

CLG

-O

CO

OL

ING

CWS

CWR

NC

CO

IL

35 F

102

PH

T-T

121

SF

-C

DM

ES

110

SF

-O

FILTERS

LS

-A

DPS

122

PR

EH

EA

T

CO

IL

OUTSIDEAIR

SEE AHU START CIRCUIT DETAIL ON SHEET THIS SHEET.

LOCATE AS SHOWN ON SHEET M102.

1. SEE SPECIFICATIONS FOR DEVICE SPECIFICATIONS.

2.ANY DEVICE REQUIRING POWER MUST BE POWERED BY

CONTRACTOR.

GENERAL NOTES:

KEYED NOTES:1

1

1

113

ST

M-O

ST

EA

M

LPS

NC

HU

MID

IFIE

R

SF#2

107

SA

-PR

S1

DPT

2

104

CLG

-T

124

ST

M-I

SO

109

SA

-PR

S3

DPT

NORTH COLDSUPPLY AIR DUCTTO SERVE NEW VAVTERMINAL UNITS

2

2

TAG #100101102103104105106107108109110111112113114115116117118119120121122123124

TYPEAIAIAIAIAIAIAIAIAIAIAOAOAOAOAOAOBIBIBIBIBIBIBOBOBO

POINT NAMESA-RHOA-TPHT-TRHT-TCLG-TSA-TSA-RH-HLSA-PRS1SA-PRS2SA-PRS3SF-OCLG-OPHT-OSTM-ORHT-OSAD-O-HDSF-S-1SF-S-2PHP-SLT-AHS-ALS-ASF-CPHP-CSTM-ISO

DESCRIPTIONSUPPLY AIR HUMIDITYOUTSIDE AIR TEMPPREHEAT AIR TEMPREHEAT COIL AIR TEMPCOOLING AIR TEMPSUPPLY AIR TEMPSUPPLY AIR HUMIDITY HIGH LIMITSUPPLY AIR STATIC PRESSURESUPPLY AIR STATIC PRESSURESUPPLY AIR STATIC PRESSURESUPPLY FAN SPEED OUTPUTCOOLING OUTPUTHEATING OUTPUTSTEAM OUTPUTREHEAT OUTPUTSUPPLY HD DAMPER OUTPUTSUPPLY FAN STATUS #1SUPPLY FAN STATUS #2PREHEAT PUMP STATUSLOW TEMP ALARMHIGH STATIC ALARMLOW STATIC ALARMSUPPLY FAN COMMANDPREHEAT PUMP COMMANDHUMIDIFIER ISOLATION VALVE

DEVICEHUMIDITY SENSORSOFTWARE INPUTRTD/DUCT AVERAGINGRTD/DUCT AVERAGINGRTD/DUCT AVERAGINGRTD/DUCT AVERAGINGHUMIDITY SENSORPRESSURE TRANSMITTERPRESSURE TRANSMITTERPRESSURE TRANSMITTERVFDELECT ACTUATOR W/SPRING RETURNELECT ACTUATOR W/SPRING RETURNELECT ACTUATOR W/SPRING RETURNELECT ACTUATOR W/SPRING RETURNELECT ACTUATOR W/SPRING RETURNCURRENT SWITCHCURRENT SWITCHCURRENT SWITCHFREEZE STATPRESSURE SWITCHPRESSURE SWITCHCONTROL RELAYCONTROL RELAYELECT ACTUATOR W/SPRING RETURN

SM

K

105SA-T

120HS-A

DP

S

1

106SA-RH-HL

HU

M

108

SA

-PR

S2

DPT

2

114

RH

T-O

HE

AT

ING

HWS

HWR

NC

CO

IL

SA

D-O

-HD

DM

118103

RH

T-T

MSF#1

SOUTH COLD DECKSUPPLY AIR

SOUTH HOT DECKSUPPLY AIR

100SA-RH

HU

M

116SF-S-1

1

1

NOTES

FRONT VIEW

DDC CONTROLLERS ARE SUPPLIED BY OWNER AND MOUNTED BY

CONTRACTOR.

KEEP ALL LOW VOLTAGE CONTROL WIRING ( UNDER 25V) AND LOW

VOLTAGE POWER WIRING (OVER 25V) SEPARATED. (RUN IN SEPARATE

CONDUIT).

PLYWOOD SIZE IS BASED ON THE NUMBER OF CONTROLLERS IN EACH

LOCATION. COORDINATE WITH OWNERS REPRESENTATIVE.

4/0 BOX WITH PULL CHAIN.18W LED LIGHT WITH GUARD.

4'x4'x3/4" PLYWOOD (MIN)(PAINT FRONT AND

ENDS MACHINE GRAY.)

1-1/2" UNISTRUTCHANNEL (2)

1.

2.

3.

6" x 6" WIRE TROUGH

FLOOR

3/4" CONDUIT

120 VAC INPUT POWER

DEDICATED 15A CIRCUIT

1" CONDUITMINIMUM

I/O

6"x6" WIRETROUGH

FLOOR

EXP. ANCHORS

1-1/2" UNISTRUTCHANNEL (2)

4'x4'x3/4" PLYWOOD (MIN)(PAINT FRONT AND ENDSMACHINE GRAY)

3/4" CONDUIT

4/0 BOX WITHPULL CHAIN. 18WLED WITH GUARD.

WA

LL

ASC ASC

BY DIVISION 26

2" MIN. CONDUIT (2)

3'-6

" T

YP

ICA

L

3' MIN DISTANCE

POSTBASE (2)

BRACEFITTING (2)

OPTIONAL FLOOR MOUNT

SIDE VIEW

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

1 P

M

505-106

M701

DPP

CONTROLS

JCS

01/11/2017

NTS2

AHU START CIRCUIT DIAGRAM

NTS1

AHU-11 CONTROL DIAGRAM

NTS3

ASC PANEL MOUNTING DETAIL

1 01/20/17 ADDENDUM 1

Page 30: CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11operations-webapps.missouri.edu/pdc/adsite/projects/cp161791/add… · PAGE 3 CP161791/ MEDICAL SCIENCE BUILDING – REPLACE AHU-11

A

B

C

VAV BOX WITH REHEAT CONTROL DIAGRAM

500 VA POWER SUPPLY DIAGRAM

FC BUS SCHEMATIC DIAGRAM

NO SCALE

NO SCALE

NO SCALE

FC COMMUNICATION BUSWIRE DAISY CHAINED TOPREVIOUS VMA CNTRLR

LOW VOLTAGEWIRE

AIR FLOWMEASURING

TAPS

AIR IN

FC COMMUNICATION BUSWIRE DAISY CHAINED TONEXT VMA CONTROLLER

DDC VMA

CONTROLLER

HWR HWS

SUPPLY AIRSENSOR

AIR OUT

AIR VALVEDAMPER

NETWORKSENSOR

T

M

ELECTRICACTUATOR

NC

SA BUSWIRE

100 VA

PSH500A

100 VA

100 VA

100 VA

100 VA

DISCONNECT

SWITCH

24V

COM

24V

COM

24V

COM

24V

COM

24V

COM

480

277

240

120

COM

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

RIB AC

BREAKER

SWITCH

ENCLOSED AC POWER SUPPLY

POWER

SUPPLY/TRANSFORMER

(FUSE)

AH-11AH-10

VAV VAVEXIST

MR M576 MR M524

S

OCCUPANCYSENSORS

KEYED NOTES:

GENERAL NOTES: KEYED NOTES:

GENERAL NOTES:

CONTROLLER WILL BE PROVIDED AND INSTALLED BY OWNER.

CONTROLLER WILL BE JCI MODEL MS-VMA-1620 SERIES. PROGRAMMING

AND COMMISSIONING WILL BE DONE BY OWNER.

NETWORK SENSOR WILL BE FURNISHED BY OWNER & INSTALLED BY

CONTRACTOR. NETWORK SENSOR WILL BE JCI NS SERIES.

FC COMMUNICATION BUS WIRE SHALL BE 22 AWG, PLENUM RATED,

TWISTED SHIELDED, 3 CONDUCTOR, WITH BLUE OUTER CASING,

DESCRIPTED AS 22-03 OAS STR PLNM NEON BLU JK DISTRIBUTED BY WINDY

CITY WIRE CONSTRUCTED BY CABLE-TEK, OR APPROVED EQUIVALENT.

SA BUS WIRE SHALL BE 22 AWG, PLENUM RATED, TWISTED SHIELDED, 4

CONDUCTOR.

PRESSURE INDEPENDENT CONTROL VALVE WITH PROPORTIONAL 0-10 VOLT

ACTUATOR.

CONTROLLER MUST HAVE A MINIMUM OF 18 INCHES OF ACCESSIBLE

CLEARANCE.

VAV SUPPLY TEMP SENSOR 1000 OHM PLATINUM RTD LOCATED APPROX. 8

FT. FROM VAV BOX DISCHARGE. PROVIDE, INSTALL AND WIRED TO

CONTROLLER BY CONTRACTOR.

FUSE LOCATED WITHIN 2 FT. OF VMA CONTROLLER.

LOW VOLTAGE WIRE BY DIVISION 23. SEE ELECTRICAL DRAWINGS FOR

SOURCE.

OCCUPANCY SENSOR(S) PROVIDED AND INSTALLED BY CONTRACTOR

WHERE INDICATED ON E-SERIES SHEETS.

1

2

3

4

5

6

7

8

9

2

4

4

7

9

3

8

1

5

6

3

EACH SECONDARY OUTPUT LINE CAN POWER 3-5 VAV CONTROLLERS

MAXIMUM. (100 VA).

PRIMARY LINE INFO: 480/277/240/120 Vac, #12 AWG MINIMUM.

SECONDARY LINE INFO: 24 Vac, #12-26 AWG, 100 VA. MAX LENGTH 175 FEET

USING #14 AWG.

DISCONNECT SWITCH REQUIRED, EXTERNALLY MOUNTED WITHIN 12

INCHES OF RIB POWER SUPPLY.

500VA POWER SUPPLY - RIB MODEL# PSMN500A OR APPROVED

EQUIVALENT.

ALL SECONDARY LINES MUST BE LABELED IN ENCLOSURE AS TO WHICH

VAV'S THEY POWER PRIOR TO ENERGIZING POWER SUPPLY.

A SEPARATE 3 AMP FUSE IS REQUIRED WITHIN 3 FEET OF EACH VAV.

1. SECONDARY LINE CAN BE RAN IN SAME CONDUIT AS FC.

2. ENCLOSED POWER SUPPLY MUST BE LOCATED IN ELECTRICAL ROOM,

MECHANICAL ROOM, OR JANITOR'S CLOSET AND BE ACCESSIBLE. ANY OTHER

LOCATION MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE.

1

2

3

4

5

6

7

5

67

3

2

4

1

FC BUS TO BE CONTINUOUS DAISY CHAIN. SEE PLANS

FOR QUANTITY AND LOCATIONS OF VAV/FCU

CONTROLLERS.

OWNER WILL MAKE TERMINATION CONNECTIONS AT

PANELS. LOCATE PANELS IN SAME ROOM AS

EQUIPMENT SERVED.

FC COMMUNICATION BUS WIRE SHALL BE 22 AWG,

PLENUM RATED, TWISTED SHIELDED, 3 CONDUCTOR,

WITH BLUE OUTER CASING, DESCRIPTED AS 22-03 OAS

STR PLNM NEON BLU JK DISTRIBUTED BY WINDY CITY

WIRE, CONSTRUCTED BY CABLE-TEK, OR APPROVED

EQUIVALENT.

COORDINATE FIELD ROUTING WITH OWNERS

REPRESENTATIVE.

1.

2.

3.

4.

10

10

SA BUS WIRE

FIFTH FLOOR

1

1

6 S

OU

TH

OL

D O

RC

HA

RD

ST

. LO

UIS

, M

O 6

31

19

T 3

14

.91

8.8

383

F 31

4.9

18.1

766

ww

w.r

ossba

r.com

CHECKED BY:

© ROSS & BARUZZINI, INC 2017

ISSUE DATE:

R&B PROJ. NO.:

DESIGNED BY:

DRAWING TITLE:

DRAWING NO.:

WHEN THIS DRAWING IS

REPRODUCED AT ORIGINAL

SCALE THIS BAR = 1 INCH

REVISIONS:

ROSS & BARUZZINI

MISSOURI STATE CERTIFICATE OF

AUTHORITY #000148

1 INCH

DATE DESCRIPTION

ME

DIC

AL S

CIE

NC

E B

UIL

DIN

GR

EP

LA

CE

AH

U-1

1M

U P

RO

JE

CT

NU

MB

ER

CP

161791

CO

LU

MB

IA, M

O

UN

IVE

RS

ITY

OF

MIS

SO

UR

I

The Professional Engineer, whose signature andpersonal seal appear on this document, assumesresponsibility only for what appears hereon, anddisclaims responsibility for all other plans,specifications, estimates, reports, documents orinstruments not sealed by the ProfessionalEngineer relating to, or intended to be used for,any part or parts of the engineering project towhich this document refers. Prints sealed by theEngineer bear the embossed or wet seal of theEngineer across the signature and date. Copies ofthis document, as signed and sealed, have beenretained by the Professional Engineer. TheProfessional Engineer will not be responsible forsubsequent changes to this document, unless thechanges are made by the Engineer or with theEngineer's written authorization.

MU PROJ. NO.: CP161791

JEFFREY R. CRAWFORDMO LICENSE NO. E-27507

1/2

0/2

017 4

:15:5

1 P

M

505-106

M702

DPP

CONTROLS

JCS

01/11/2017

1 01/20/17 ADDENDUM 1