Nokia Indoor Location Measurement Unit
Installation
User Manual, Version 4
469194A.203_nols
DN0112195 © Nokia Corporation 1 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
The information in this documentation is subject to change without notice and describes onlythe product defined in the introduction of this documentation. This documentation is intendedfor the use of Nokia's customers only for the purposes of the agreement under which thedocumentation is submitted, and no part of it may be reproduced or transmitted in any form ormeans without the prior written permission of Nokia. The documentation has been prepared tobe used by professional and properly trained personnel, and the customer assumes fullresponsibility when using it. Nokia welcomes customer comments as part of the process ofcontinuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity,or performance of the mentioned hardware or software products cannot be considered bindingbut shall be defined in the agreement made between Nokia and the customer. However, Nokiahas made all reasonable efforts to ensure that the instructions contained in the documentationare adequate and free of material errors and omissions. Nokia will, if necessary, explain issueswhich may not be covered by the documentation.
Nokia's liability for any errors in the documentation is limited to the documentary correction oferrors. NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL(INCLUDING MONETARY LOSSES), that might arise from the use of this documentation orthe information in it.
This documentation and the product it describes are considered protected by copyrightaccording to the applicable laws.
NOKIA logo is a registered trademark of Nokia Corporation.
Other product names mentioned in this documentation may be trademarks of their respectivecompanies, and they are mentioned for identification purposes only.
Copyright © Nokia Corporation 2002. All rights reserved.
2 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Contents
Contents 3
List of tables 4
List of figures 5
1 About this document 7
2 Contents of the delivery 92.1 Standard delivery items 92.2 Alternative delivery items 102.3 Optional delivery items 13
3 Working order 15
4 Unpacking and inspecting the delivery 17
5 Installing Nokia Indoor LMU 195.1 Installing the mounting bracket 195.2 Installing the LMU module 225.3 Installing the optional AC/DC power supply 23
6 Interface cabling 256.1 Nokia Indoor LMU interfaces 256.2 LMU-BTS interface cables 286.3 Cabling 306.3.1 Cabling with DE21/DF12/DG26 BTSs 306.3.2 Cabling with Nokia Intratalk and Nokia Citytalk BTSs 436.3.3 Cabling with Nokia UltraSite GSM/EDGE BTSs 476.3.4 EXT Q1 cabling 50
7 Completing the installation 51
DN0112195 © Nokia Corporation 3 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
List of tables
Table 1. Nokia Indoor LMU interfaces 26
Table 2. BTS/Q1 pinout 26
Table 3. COM/LMP pinout 27
Table 4. EXT/Q1 pinout 28
4 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
List of figures
Figure 1. Standard delivery items 10
Figure 2. Alternative delivery items 12
Figure 3. Optional delivery items 14
Figure 4. Alternative methods for installing the mounting bracket 21
Figure 5. Installing the LMU module to the mounting bracket 23
Figure 6. Nokia Indoor LMU interfaces 25
Figure 7. Pin order of the BTS/Q1 interface connector 26
Figure 8. Pin order of the COM/LMP interface connector 27
Figure 9. Pin order of the EXT/Q1 interface connector 27
Figure 10. LMU-BTS interface cables designed for different BTSs 29
Figure 11. Cabling with Mini Indoor and Sector Indoor cabinets (continues in Figure12) 32
Figure 12. Cabling with Mini Indoor and Sector Indoor cabinets (continued fromFigure 11) 33
Figure 13. Cabling with Streetlevel/All Climate Streetlevel Outdoor cabinets 35
Figure 14. Cabling with Rooftop/All Climate Rooftop Outdoor cabinets (continues inFigure 15) 38
Figure 15. Cabling with Rooftop/All Climate Rooftop Outdoor cabinets (continuedfrom Figure 14) 39
Figure 16. Cabling with All Climate Rooftop Outdoor cabinet (continues in Figure17) 42
Figure 17. Cabling with All Climate Rooftop Outdoor cabinet (continued from Figure16) 43
Figure 18. Cabling with Nokia Intratalk and Nokia Citytalk BTSs (continues in Figure19) 46
Figure 19. Cabling with Nokia Intratalk and Nokia Citytalk BTSs (continued fromFigure 18) 47
Figure 20. Cabling with Nokia UltraSite GSM/EDGE BTSs 49
DN0112195 © Nokia Corporation 5 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
6 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
About this document
1 About this documentThis document describes the installation of Nokia Indoor Location MeasurementUnit (LMU). Read carefully Requirements for Installation and Operation beforestarting the installation.
The document contains the following information:
• Contents of Nokia Indoor LMU delivery
• Working order
• Unpacking and inspecting the delivery
• Installing Nokia Indoor LMU
• Interface cabling with different base stations
• Completing the installation
DN0112195 © Nokia Corporation 7 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
8 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Contents of the delivery
Note
Note
2 Contents of the deliveryThis chapter presents the contents of the Nokia Indoor LMU delivery.
All items of a single Nokia Indoor LMU configuration are delivered in the samepackage. If you have ordered several accessory items not matching theconfiguration, these will be delivered in a separate package.
2.1 Standard delivery items
The following items are always included in the Nokia Indoor LMU deliverypackage:
• LMU module with factory-flashed LMU SW
• LMU mounting bracket
• Fixing parts for securing the mounting bracket:
- TORX screws (M4, 4 pcs)- blind nuts (4 pcs) with TORX screws (M4, 4 pcs)- self-tapping screws (4 pcs)- two-sided tape (2 pcs)
• Grounding (earthing) cable
Refer also to Figure 1.
The fixing parts for the mounting bracket cannot be ordered separately, but aredelivered together with the mounting bracket and the selected LMU-BTSinterface cable.
DN0112195 © Nokia Corporation 9 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 1. Standard delivery items
2.2 Alternative delivery items
The following list presents the alternative items included in the Nokia IndoorLMU delivery package depending on customer order:
LMU module LMU mounting bracket
Fixing parts
TORX screws Two-sided tape
Self-tapping screws
Blind nuts
TORX screws forblind nuts
Grounding cable
DN0125552
10 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Contents of the delivery
• LMU GPS antenna
• LMU-BTS interface cable for:
- Mini Indoor cabinet (DE21 BTS), Sector Indoor cabinet(DE21/DF12 BTSs), and Streetlevel/All Climate StreetlevelOutdoor cabinets (DE21/DF12 BTSs)
- Rooftop/All Climate Rooftop Outdoor cabinets (DE21/DF12/DG26BTSs)
- Nokia Intratalk/Nokia Citytalk BTSs- Nokia UltraSite GSM/EDGE BTSs
• Internal LMU GSM RX antennas
- Basic Cable Antenna/Coupler kit- Nokia UltraSite Cable Antenna/Coupler kit- Nokia IntraTalk Cable Antenna/Coupler kit- Combiner kit for Cable Antenna/Coupler
• External LMU GSM RX antennas
- one directional LMU GSM RX antenna- one omnidirectional LMU GSM RX antenna- directional coupler for RX feeder lines (20 dB)
• Antenna alternatives
- N-N antenna jumper cable- N-SMA antenna jumper cable- GPS EMP protector- GSM EMP protector
Refer also to Figure 2.
DN0112195 © Nokia Corporation 11 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 2. Alternative delivery items
Pole-mountedGPS antenna
DirectionalLMU GSM RX antenna
OmnidirectionalLMU GSM RX antenna
N-N jumper cableCombiner Jumper cable for LMU GPSand LMU GSM RX antennas
GSM EMPprotector
GPS EMP protectorFeedthroughplate
Cable Antenna
Directional coupler
LMU-BTS interface cable (example: Nokia UltraSite
GSM/EDGE BTSs)
DN0128331
Ferrite ring
SMA - SMAjumper cable
50 ohm Terminator
SMA angle-N jumper cable
SMA angle - SMA jumper cable
12 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Contents of the delivery
Note
2.3 Optional delivery items
The following optional items are delivered only on customer-specific order:
• LMU SW (in BSC and Nokia NetAct formats) and LMU Manager SW kitin CD-ROM
• External AC/DC power supply
• Manager cable (with pins 2 and 3 crossed, pin 5 as ground)
• Extension cable kit: BTS extension cable and EXT/Q1 adapter cable
• Antenna T-bracket
• Outdoor mechanics kit
Refer also to Figure 3.
If chaining different types of BTSs to the same clock chain, you need to order thechaining cables separately. For more information, please refer to the relevant BTSco-siting manuals.
DN0112195 © Nokia Corporation 13 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 3. Optional delivery items
LMU SW and LMU Manager SWkit CD-ROM
External AC/DC power supply
Manager cable Extension cable kit
BTS extension cable EXT/Q1 adapter cable
DN00302437
Antenna T-bracketOutdoor mechanics kit
14 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Working order
Note
3 Working orderThis chapter provides a general overview of the working order for Nokia IndoorLMU installation. Each work phase is described in more detail in subsequentchapters.
Antennas must be installed before or simultaneously with the installation of theLMU (refer to the Antenna Requirements document).
To install Nokia Indoor LMU, proceed in the following order:
1. Complete site planning and site survey according to specificationsprovided in Requirements for Installation and Operation.
2. Unpack the delivery and inspect the contents for any visible damage.
3. Install the mounting bracket.
4. Ground the LMU module and the external AC/DC power supply’s cable (ifused).
5. Connect the cables.
6. Install the LMU module to the mounting bracket.
7. Recycle all applicable material.
DN0112195 © Nokia Corporation 15 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
16 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Unpacking and inspecting the delivery
Caution
Caution
Caution
4 Unpacking and inspecting the deliveryThis chapter describes how to unpack and inspect the contents of the NokiaIndoor LMU delivery package.
Handle Nokia Indoor LMU with care. Do not drop Nokia Indoor LMU or thepackage containing it.
Use an antistatic wrist strap when unpacking the delivery items.
Do not take the cables out of their plastic bags or remove the connector shieldsfrom both ends of the LMU module until you start the actual installation.
To unpack and inspect the delivery package:
1. Open the packing cardboard and take all the delivery items out of thepackage.
2. Check the completeness of the delivery against the packing list (see alsoChapter 2 in this document).
3. Inspect all the delivery items visually for any defects.
DN0112195 © Nokia Corporation 17 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
4. Recycle the packing material.
If any contents of the delivery are damaged or missing, immediately report thesefindings to your local Nokia representative.
18 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Installing Nokia Indoor LMU
Caution
Caution
5 Installing Nokia Indoor LMUThis chapter instructs how to install Nokia Indoor LMU. Tools and equipmentneeded in the installation are described in Requirements for Installation andOperation.
Installation, commissioning, and maintenance measures concerning Nokia IndoorLMU may be performed only by properly trained and authorised personnel.
Use an antistatic wrist strap when installing Nokia Indoor LMU.
5.1 Installing the mounting bracket
To install the mounting bracket:
1. Position the mounting bracket inside or on top of the BTS, or to a wall nearthe BTS. See Requirements for Installation and Operation for therecommended BTS-specific installation locations and required clearances.
2. Secure the mounting bracket to the mounting base. You can use threealternative fixing methods in BTS installation and one method in wallinstallation:
DN0112195 © Nokia Corporation 19 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
WARNING
Caution
Note
Before drilling any holes to the wall, ensure that there is no piping or electricwiring inside/behind it.
Do not drill any holes to the BTS cabinet.
Any of the mounting bracket holes can be used to secure it to the BTS cabinet orwall. Anchor plugs for wall mounting (if required) are customer-supplied.
a. With Nokia UltraSite GSM/EDGE BTSs, secure the mountingbracket from appropriate holes to the threaded holes on the BTScabinet with the shorter M4 TORX screws (see A of Figure 4).
b. With other BTSs, use the blind nuts and the longer M4 TORXscrews to fix the mounting bracket to larger holes (ø 8 - 9 mm/0.31- 0.35 in.) on the BTS cabinet.
Press the blind nuts through the holes on the BTS cabinet and securethe mounting bracket to the blind nuts with the TORX screws (see Bof Figure 4).
c. If the BTS cabinet does not have any holes where the mountingbracket fixing screws can be secured, use the two-sided tape tosecure the mounting bracket (see C of Figure 4). Clean the BTSmounting base before applying the tape.
d. If BTS installation is not possible or wall installation is preferred,install the mounting bracket to a wall. Depending on the wall type,use either the included self-tapping screws or other appropriatefixing screws to secure the mounting bracket (see D of Figure 4).
If using anchor plugs (or other appropriate counterparts), drill fourholes to the wall and insert the anchor plugs into the holes. Tightenthe upper and lower fixing screws to secure the mounting bracket.
20 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Installing Nokia Indoor LMU
Figure 4. Alternative methods for installing the mounting bracket
D
Self-tappingscrews
DN0136168
TORXscrews
A
Two-sidedtape
C
B
TORXscrews
Blind nuts
DN0112195 © Nokia Corporation 21 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Caution
Note
Note
5.2 Installing the LMU module
Ground the LMU module and the external AC/DC power supply’s cable (if used)before installing the LMU module to the mounting bracket (refer to Requirementsfor Installation and Operation).
If preferred, you can connect the cables to the LMU module before installing it tothe mounting bracket (see Chapter 6).
To install the LMU module to the mounting bracket:
If the external AC/DC power supply is used, install the LMU module in such away that the PWR/VDC connector on its side is left unobstructed.
1. Place one of the long edges of the LMU module under the longer side plateof the mounting bracket with the indicator LEDs facing up (see 1 of Figure5).
2. Press down the LMU module until it clicks into place between the sideplates of the mounting bracket (see 2 of Figure 5).
22 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Installing Nokia Indoor LMU
Note
Figure 5. Installing the LMU module to the mounting bracket
5.3 Installing the optional AC/DC power supply
Install the external AC/DC power supply to an easily accessible location - on orinside a pole or to a wall - in an upright position with the cables leavingdownwards. All fixing parts used in the installation are customer-supplied.
Nokia recommends wall mounting of the external AC/DC power supply becausethis requires the use of only four self-tapping screws. Select a screw type suitablefor the wall and check if anchor plugs are required (for example for concreteelement and brick walls). If pole mounting is used, you need a metal band and/orother additional fixing parts to secure the external AC/DC power supply.
When installed, the distance of the external AC/DC power supply from thegrounded socket-outlet must not exceed 1.5 m (4.9 ft.), and from Nokia IndoorLMU 5 m (16.4 ft.).
Securing of the external AC/DC power supply must meet the same vibration andearthquake requirements set for Nokia Indoor LMU (refer to Requirements forInstallation and Operation).
1
PWR/VDC connector
Install the LMU module betweentheside plates of the mounting bracket
ExternalAC/DC PSU
cable
Groundingcable
2 Press down the LMU moduleuntilit clicks into place
DN0136183
DN0112195 © Nokia Corporation 23 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
24 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
6 Interface cablingThis chapter details the Nokia Indoor LMU interfaces and the LMU-BTSinterface cables, and provides instructions on how to connect the cables.
6.1 Nokia Indoor LMU interfaces
Figure 6 illustrates the interface connectors of Nokia Indoor LMU.
Figure 6. Nokia Indoor LMU interfaces
The interface connectors are listed also in Table 1. The prefix in parentheses aftereach interface connector corresponds to the marking at the bottom of the LMUmodule.
GSM
COM/LMP
EXT/Q1
BTS/Q1
PWR/VDC (for optionalexternal AC/DC PSU)
GPS
DN0183109
DN0112195 © Nokia Corporation 25 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 7 illustrates the pin order of the BTS/Q1 interface connector.
Figure 7. Pin order of the BTS/Q1 interface connector
Table 2 lists the pinout of the BTS/Q1 interface connector.
Figure 8 illustrates the pin order of the COM/LMP interface connector.
Table 1. Nokia Indoor LMU interfaces
Interface connector Connector type
External AC/DC power supply (PWR/VDC) Molex type 43045-0401male
LMU GPS antenna (GPS) SMA female
LMU GSM RX antenna (GSM) SMA female
LMU-BTS Q1 interface (BTS/Q1) D15 male
External Q1 interface (EXT/Q1) D9 female
Commissioning/Local Management Port (COM/LMP) D9 female
1 2 3 4 5 6 7 8
159 10 11 12 13 14
DN01140375
Table 2. BTS/Q1 pinout
Pin Signal Pin Signal Pin Signal
1 Q1 TX + 6 FNO + 11 SBCK -
2 Q1 TX - 7 FCLK - 12 SBCK +
3 Q1 RX - 8 FCLK + 13 TCLK -
4 Q1 RX + 9 PWR GND 14 TCLK +
5 FNO - 10 48V O 15 GND
26 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 8. Pin order of the COM/LMP interface connector
Table 3 lists the pinout of the COM/LMP interface connector.
Figure 9 illustrates the pin order of the EXT/Q1 interface connector.
Figure 9. Pin order of the EXT/Q1 interface connector
Table 4 lists the pinout of the EXT/Q1 interface connector.
12345
69 78
DN0225587
Table 3. COM/LMP pinout
Pin Signal Pin Signal Pin Signal
1 NC 4 NC 7 NC
2 RS232 RX 5 GND 8 NC
3 RS232 TX 6 NC 9 NC
12345
69 78
DN0225599
DN0112195 © Nokia Corporation 27 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
6.2 LMU-BTS interface cables
A special LMU-BTS interface cable is designed for the following BTSs:
• DE21/DF12/DG26 BTSs:
- Mini Indoor and Sector Indoor cabinets (see A of Figure 10)- Streetlevel/All Climate Streetlevel Outdoor cabinets (see B of
Figure 10)- Rooftop/All Climate Rooftop Outdoor cabinets (see C of Figure 10)
• Nokia Intratalk/Nokia Citytalk BTSs (see D of Figure 10)
• Nokia UltraSite GSM/EDGE BTSs (see E of Figure 10).
Table 4. EXT/Q1 pinout
Pin Signal Pin Signal Pin Signal
1 Q1 RX + 4 EXT FCLK - 7 EXT FCLK +
2 EXT FCLK - 5 Q1 TX + 8 EXT FNO +
3 GND 6 Q1 RX - 9 Q1 TX -
28 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 10. LMU-BTS interface cables designed for different BTSs
Nokia UltraSite GSM/EDGE BTSs
Cabinet input Q1
E
BTS/Q1 LMU
B Streetlevel/All Climate StreetlevelOutdoor cabinets (DE21 BTS)
BTS/Q1 LMU PSUQ1 PSUQ1+
C
BTS/Q1 LMU
Rooftop/All Climate Rooftop Outdoorcabinets (DE21/DF12/DG26 BTSs)
Q1-
Mini Indoor cabinet (DE21 BTS)/Sector Indoor cabinet (DE21/DF12 BTSs)
BTS/Q1 LMU PSUQ1
LMU-BTS interface cable EACB cable
EACB1 EACB2/Q1Q1
A
Fuselink extension
Nokia Intratalk/Nokia Citytalk BTSs
PSUFCLK/FN
TCLK/SBCKQ1
D
BTS/Q1 LMU
DN0136195
DN0112195 © Nokia Corporation 29 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
6.3 Cabling
6.3.1 Cabling with DE21/DF12/DG26 BTSs
To connect the cables with Mini Indoor cabinet (DE21 BTS) andSector Indoor cabinet (DE21/DF12 BTSs):
1.
a. Connect the feeder and jumper cables of the LMU GPS and LMUGSM RX antennas to the GPS and GSM EMP protectors (withfemale N-connectors) as shown in 1a of Figure 11.
b. If using internal GSM antenna, GSM EMP protector is not necessaryand the cable can be connected directly to the Cable Antenna asshown in 1b of Figure 11 or with an SMA-SMA jumper cable to thecombiner.
The grounding screws of the GPS and GSM EMP protectors should be fixed to agood grounding point - preferably the same point used for the BTS EMPprotectors.
2. Connect the jumper cables of the LMU GPS and LMU GSM RX antennasto the GPS and GSM connectors (SMA) on the LMU module (see 2 ofFigure 11). Use an SMA Torque wrench to tighten the SMA connectors to1.0 Nm (0.74 ft-lb).
3. Connect the BTS/Q1 LMU interface to the BTS/Q1 connector on the LMUmodule (see 2 of Figure 11). Tighten the fixing screws of BTS/Q1 interfaceD-connector by hand.
4. Connect the Q1 interface to a free Euroconnector slot (BCI) located on theBTS cabinet top (see 3 of Figure 11).
5. Connect the EACB cable (see 4 of Figure 12).
Connect the EACB1 interface to the EACB1/IN connector and theEACB2/Q1 interface to the EACB2/OUT connector on the EACB unit ofthe BTS.
Connect the Q1 interface to the opposite side of the LMU-BTS cable’s Q1interface on the Euroconnector slot.
30 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Note
Note
WARNING
Note
6. Connect the fuse-link extensions and the PSU lines or the power supplycable.
If there is DC power available from the BTS, connect the fuse-linkextensions to the BTS’s terminal block and the PSU lines to the fuse-link’sterminal socket (see 5 of Figure 12).
The fuse-link must be used to prevent high current in case of faulty cabling orshort circuit caused by the installer.
The order of the fuse-link extensions in the BTS’s terminal block is not importantbecause Nokia Indoor LMU functions with both polarities.
7. Check the correct cabling from 6 in Figure 12.
8. If there is no DC power available from the BTS, connect the externalAC/DC power supply’s cable to the PWR/VDC connector on the LMUmodule (see 7 of Figure 12). Connect the other end of the cable to agrounded socket-outlet at the BTS site or use a grounded fixed mainsinstallation.
Fixed mains installation may be performed only by properly trained andauthorised personnel.
If using the external AC/DC power supply, leave the PSU lines of the LMU-BTSinterface cable unconnected and shield them with appropriate sleeves.
DN0112195 © Nokia Corporation 31 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 11. Cabling with Mini Indoor and Sector Indoor cabinets (continues inFigure 12)
DN0136202
1a
GPS
GSM
Jumpercables
Feedercables
Connect the GPS and GSM EMPprotectors to the cables
2 Connect the antenna jumper cablesand the BTS/Q1 LMU interface
GPS GSM
GPS
Jumpercables
Feedercable
Connect the GPS EMP protectorand Cable Antenna to the cables
1b
CableAntenna
Connect the Q1 interface3
Front of thecabinet
32 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 12. Cabling with Mini Indoor and Sector Indoor cabinets (continued fromFigure 11)
To connect the cables with Streetlevel/All Climate Streetlevel Outdoorcabinets (DE21 BTS):
1.
4
EACB1
EACB2/Q1
Q1
Connect the EACB cable
Correct cabling 6
5 Connect the fuse-link extensionsand the PSU lines
DN03272904
Connect the external AC/DCpower supply's cable
7
DN0112195 © Nokia Corporation 33 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
Note
a. Connect the feeder and jumper cables of the LMU GPS and LMUGSM RX antennas to the GPS and GSM EMP protectors (withfemale N-connectors) as shown in 1a of Figure 13.
b. If using internal GSM antenna, GSM EMP protector is not necessaryand the cable can be connected directly to the Cable Antenna asshown in 1b of Figure 13.
The grounding screws of the GPS and GSM EMP protectors should be fixed to agood grounding point - preferably the same point used for the BTS EMPprotectors.
2. Connect the jumper cables of the LMU GPS and LMU GSM RX antennasto the GPS and GSM connectors (SMA) on the LMU module (see 2 ofFigure 13). Use an SMA Torque wrench to tighten the SMA connectors to1.0 Nm (0.74 ft-lb).
3. Connect the BTS/Q1 LMU interface to the BTS/Q1 connector on the LMUmodule (see 2 of Figure 13). Tighten the fixing screws of BTS/Q1 interfaceD-connector by hand.
4. Connect the Q1 interface to the top part of the X13 Euroconnector slotlocated inside the BTS, close to the cabinet floor (see 3 of Figure 13).
5. Connect the external AC/DC power supply’s cable to the PWR/VDCconnector on the LMU module (see 4 of Figure 13). Connect the other endof the cable to a grounded socket-outlet inside the BTS cabinet.
Leave the PSU lines of the LMU-BTS interface cable unconnected and shieldthem with appropriate sleeves.
34 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 13. Cabling with Streetlevel/All Climate Streetlevel Outdoor cabinets
DN01144535
3 Connect the Q1 interface
X13
4 Connect the external AC/DCpower supply's cable
1a
GPS
GSM
Jumpercables
Feedercables
Connect the GPS and GSM EMPprotectors to the cables
2 Connect the antenna jumper cablesand the BTS/Q1 LMU interface
GPS GSM
GPS
Jumpercables
Feedercable
Connect the GPS EMP protectorand Cable Antenna to the cables
1b
CableAntenna
DN0112195 © Nokia Corporation 35 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
To connect the cables with Rooftop/All Climate Rooftop Outdoorcabinets (DE21/DF12 BTSs):
1.
a. Connect the feeder and jumper cables of the LMU GPS and LMUGSM RX antennas to the GPS and GSM EMP protectors (withfemale N-connectors) as shown in 1a of Figure 14.
b. If using internal GSM antenna, GSM EMP protector is not necessaryand the cable can be connected directly to the Cable Antenna asshown in 1b of Figure 14.
The grounding screws of the GPS and GSM EMP protectors should be fixed to agood grounding point - preferably the same point used for the BTS EMPprotectors.
2. Connect the jumper cables of the LMU GPS and LMU GSM RX antennasto the GPS and GSM connectors (SMA) on the LMU module (see 2 ofFigure 14). Use an SMA Torque wrench to tighten the SMA connectors to1.0 Nm (0.74 ft-lb).
3. Connect the BTS/Q1 LMU interface to the BTS/Q1 connector on the LMUmodule (see 2 of Figure 14). Tighten the fixing screws of BTS/Q1 interfaceD-connector by hand.
4. Remove the shield plate from the cable entry on the BTS cabinet top androute the EACB1 and EACB2/Q1 interfaces through the opening (see 3 ofFigure 14).
5. Connect the EACB1 interface to the EACB1/IN connector and theEACB2/Q1 interface to the EACB2/OUT connector on the EACB unit ofthe BTS (see 4 of Figure 15).
6. Connect the fuse-link extensions and the PSU lines or the power supplycable.
36 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Note
WARNING
Note
If there is DC power available from the BTS, connect the fuse-linkextensions to the BTS’s terminal block and the PSU lines to the fuse-link’sterminal socket (see 5a of Figure 15).
The order of the fuse-link extensions in the BTS’s terminal block is not importantbecause Nokia Indoor LMU functions with both polarities.
If there is no DC power available from the BTS, connect the externalAC/DC power supply’s cable to the PWR/VDC connector on the LMUmodule (see 5b of Figure 15). Connect the other end of the cable to agrounded socket-outlet at the BTS site or use a grounded fixed mainsinstallation.
Fixed mains installation may be performed only by properly trained andauthorised personnel.
If using the external AC/DC power supply, leave the PSU lines of the LMU-BTSinterface cable unconnected and shield them with appropriate sleeves.
DN0112195 © Nokia Corporation 37 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 14. Cabling with Rooftop/All Climate Rooftop Outdoor cabinets(continues in Figure 15)
Route the EACB interfaces throughthe cable entry opening
3
12
1a
GPS
GSM
Jumpercables
Feedercables
Connect the GPS and GSM EMPprotectors to the cables
DN01144547
2 Connect the antenna jumper cablesand the BTS/Q1 LMU interface
GPS GSM
GPS
Jumpercables
Feedercable
Connect the GPS EMP protectorand Cable Antenna to the cables
1b
CableAntenna
38 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 15. Cabling with Rooftop/All Climate Rooftop Outdoor cabinets(continued from Figure 14)
To connect the cables with All Climate Rooftop Outdoor cabinet(DG26 BTS):
1.
Connect the external AC/DCpower supply's cable
5b
5a Connect the fuse-link extensionsand the PSU lines
4
EACB1
EACB2/Q1
Connect the EACB interfaces
DN03272916
DN0112195 © Nokia Corporation 39 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
Note
a. Connect the feeder and jumper cables of the LMU GPS and LMUGSM RX antennas to the GPS and GSM EMP protectors (withfemale N-connectors) as shown in 1a of Figure 16.
b. If using internal GSM antenna, GSM EMP protector is not necessaryand the cable can be connected directly to the Cable Antenna asshown in 1b of Figure 16 or with an SMA-SMA jumper cable to thecombiner.
The grounding screws of the GPS and GSM EMP protectors should be fixed to agood grounding point - preferably the same point used for the BTS EMPprotectors.
2. Connect the jumper cables of the LMU GPS and LMU GSM RX antennasto the GPS and GSM connectors (SMA) on the LMU module (see 2 ofFigure 16). Use an SMA Torque wrench to tighten the SMA connectors to1.0 Nm (0.74 ft-lb).
3. Connect the BTS/Q1 LMU interface to the BTS/Q1 connector on the LMUmodule (see 2 of Figure 16). Tighten the fixing screws of BTS/Q1 interfaceD-connector by hand.
4. Remove the shield plate from the cable entry on the BTS cabinet top androute the EACB1 and EACB2/Q1 interfaces through the opening (see 3 ofFigure 16).
5. Connect the EACB1 interface to the EACB1/IN connector and theEACB2/Q1 interface to the EACB2/OUT connector on the EACB unit ofthe BTS (see 4 of Figure 17).
6. Connect the fuse-link extensions and the PSU lines or the power supplycable.
If there is DC power available from the BTS, connect the fuse-linkextensions to the BTS’s terminal block and the PSU lines to the fuse-link’sterminal socket (see 5a of Figure 17).
The order of the fuse-link extensions in the BTS’s terminal block is not importantbecause Nokia Indoor LMU functions with both polarities.
40 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
WARNING
Note
If there is no DC power available from the BTS, connect the externalAC/DC power supply’s cable to the PWR/VDC connector on the LMUmodule (see 5b of Figure 17). Connect the other end of the cable to agrounded socket-outlet at the BTS site or use a grounded fixed mainsinstallation.
Fixed mains installation may be performed only by properly trained andauthorised personnel.
If using the external AC/DC power supply, leave the PSU lines of the LMU-BTSinterface cable unconnected and shield them with appropriate sleeves.
DN0112195 © Nokia Corporation 41 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 16. Cabling with All Climate Rooftop Outdoor cabinet (continues inFigure 17)
1a
GPS
GSM
Jumpercables
Feedercables
Connect the GPS and GSM EMPprotectors to the cables
DN01144559
2 Connect the antenna jumper cablesand the BTS/Q1 LMU interface
GPS GSM
Route the EACB interfaces throughthe cable entry opening
3
12
GPS
Jumpercables
Feedercable
Connect the GPS EMP protectorand Cable Antenna to the cables
1b
CableAntenna
42 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Note
Figure 17. Cabling with All Climate Rooftop Outdoor cabinet (continued fromFigure 16)
6.3.2 Cabling with Nokia Intratalk and Nokia Citytalk BTSs
If BSS synchronisation is used with Nokia Intratalk and Nokia Citytalk BTSs,ensure that the BTS has the correct ABSA board and BCFB unit (with clockconnections) installed.
Connect the external AC/DCpower supply's cable
5b
5a Connect the fuse-link extensionsand the PSU lines
4
EACB1
EACB2/Q1
Connect the EACB interfaces
DN03272928
DN0112195 © Nokia Corporation 43 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
Note
To connect the cables with Nokia Intratalk and Nokia Citytalk BTSs:
1.
a. Connect the feeder and jumper cables of the LMU GPS and LMUGSM RX antennas to the GPS and GSM EMP protectors (withfemale N-connectors) as shown in 1a of Figure 18.
b. If using internal GSM antenna, GSM EMP protector is not necessaryand the cable can be connected directly to the Cable Antenna or withan SMA-SMA jumper cable to the combiner as shown in 1b ofFigure 18.
The grounding screws of the GPS and GSM EMP protectors should be fixed to agood grounding point - preferably the same point used for the BTS EMPprotectors.
2. Connect the jumper cables of the LMU GPS and LMU GSM RX antennasto the GPS and GSM connectors (SMA) on the LMU module (see 2 ofFigure 18). Use an SMA Torque wrench to tighten the SMA connectors to1.0 Nm (0.74 ft-lb).
3. Connect the BTS/Q1 LMU interface to the BTS/Q1 connector on the LMUmodule (see 2 of Figure 18). Tighten the fixing screws of BTS/Q1 interfaceD-connector by hand.
4. Connect the Q1 interface to the Q1 connector on the ABSA board of theBTS (see 3 of Figure 18).
5. If BSS synchronisation is used, connect the FCLK/FN and TCLK/SBCKclock output interfaces to the respective clock input connectors on theABSA board of the BTS (see 4 of Figure 19).
If BSS synchronisation is not used, leave the FCLK/FN and TCLK/SBCKinterfaces unconnected and shield them with appropriate sleeves.
6. Connect the fuse-link extensions and the PSU lines or the power supplycable.
44 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Note
Note
WARNING
Note
If there is DC power available from the BTS, connect the fuse-linkextensions to the BTS’s terminal block and the PSU lines to the fuse-link’sterminal block (see 5a of Figure 19).
The fuse-link must be used to prevent high current in case of faulty cabling orshort circuit caused by the installer.
The order of the fuse-link extensions in the BTS’s terminal block is not importantbecause Nokia Indoor LMU functions with both polarities.
If there is no DC power available from the BTS, connect the externalAC/DC power supply’s cable to the PWR/VDC connector on the LMUmodule (see 5b of Figure 19). Connect the other end of the cable to agrounded socket-outlet at the BTS site or use a grounded fixed mainsinstallation.
Fixed mains installation may be performed only by properly trained andauthorised personnel.
If using the external AC/DC power supply, leave the PSU lines of the LMU-BTSinterface cable unconnected and shield them with appropriate sleeves.
DN0112195 © Nokia Corporation 45 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Figure 18. Cabling with Nokia Intratalk and Nokia Citytalk BTSs (continues inFigure 19)
DN0136214
Connect the Q1 interface3
1a
GPS
GSM
Jumpercables
Feedercables
Connect the GPS and GSM EMPprotectors to the cables
2 Connect the antenna jumper cablesand the BTS/Q1 LMU interface
GPS GSM
GPS
Combiner
Jumpercables
Feedercable
Connect the GPS EMP protectorand combiner to the cables
1b
46 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 19. Cabling with Nokia Intratalk and Nokia Citytalk BTSs (continued fromFigure 18)
6.3.3 Cabling with Nokia UltraSite GSM/EDGE BTSs
To connect the cables with Nokia UltraSite GSM/EDGE BTSs:
1.
4 Connect the FCLK/FN andTCLK/SBCK interfaces
5a Connect the fuse-link extensionsand the PSU lines
Connect the external AC/DCpower supply's cable
5b
DN03272955
DN0112195 © Nokia Corporation 47 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
Note
a. Connect the feeder and jumper cables of the LMU GPS and LMUGSM RX antennas to the GPS and GSM EMP protectors (withfemale N-connectors) as shown in 1a of Figure 20.
b. If using internal GSM antenna, GSM EMP protector is not necessaryand the cable can be connected directly to the Cable Antenna or withan SMA-SMA jumper cable to the combiner as shown in 1b ofFigure 20.
The grounding screws of the GPS and GSM EMP protectors should be fixed to agood grounding point - preferably the same point used for the BTS EMPprotectors.
2. Connect the jumper cables of the LMU GPS and LMU GSM RX antennasto the GPS and GSM connectors (SMA) on the LMU module (see 2 ofFigure 20). Use an SMA Torque wrench to tighten the SMA connectors to1.0 Nm (0.74 ft-lb).
3. Connect the BTS/Q1 LMU interface to the BTS/Q1 connector on the LMUmodule (see 2 of Figure 20). Tighten the fixing screws of BTS/Q1 interfaceD-connector by hand.
4. Connect the Q1 interface to the Q1_1 or Q1_2 connector on the interfacemodule of the BTS (see 3 of Figure 20). Some early versions of US BTScabinets require short Q1 adapter cable at the connector to correct the Q1pin order.
5. Connect the cabinet input interface to the cabinet input connector on theinterface module of the BTS (see 4 of Figure 20).
48 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Interface cabling
Figure 20. Cabling with Nokia UltraSite GSM/EDGE BTSs
1a
GPS
GSM
Jumpercables
Feedercables
Connect the GPS and GSMEMPprotectors to the cables
Connect the Cabinet input interface4
Connect the Q1 interface3
DN0136226
2 Connect the antenna jumper cablesand the BTS/Q1 LMU interface
GPS GSM
GPS
Combiner
Jumpercables
Feedercable
Connect the GPS EMP protectorand combiner to the cables
1b
DN0112195 © Nokia Corporation 49 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
6.3.4 EXT Q1 cabling
Nokia Indoor LMU has an extra Q1 connector which allows chaining of Q1equipment to the same Q1 bus. Second synchronisation output signals are alsoavailable at this connector.
To connect another Q1 equipment:
• Connect the Q1 cable of the equipment (D9 connector) to the LMU’sexternal Q1 connector. Tighten the fixing screws of EXT/Q1 interface D-connector by hand.
To use second synchronisation outputs to non-compatible BTS:
1. Connect the EXT Q1 adapter cable’s D9 interface to the EXT/Q1connector on the LMU module.
2. Connect the EXT Q1 adapter cable’s D15 interface to the second BTSclock chain to be synchronised.
Tighten the fixing screws of D9 and D15 connectors by hand.
An additional D9 interface of the EXT Q1 adapter cable remains available foranother external Q1 device.
50 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en
Completing the installation
7 Completing the installation
To complete the installation, do the following:
1. Check that all the cables are properly and correctly connected.
2. Check that the LMU module is properly installed to the mounting bracketand the mounting bracket is firmly secured to its mounting base.
3. Clean the site. Recycle any applicable material.
DN0112195 © Nokia Corporation 51 (52)Issue 4-1 en Nokia Proprietary and Confidential
Installation
52 (52) © Nokia Corporation DN0112195Nokia Proprietary and Confidential Issue 4-1en