Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for...

16
Cables for alarm- and safety systems Flexible and safe solutions, for decades.

Transcript of Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for...

Page 1: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Cables for alarm- and safety systems

Flexible and

safe solutions,

for decades.

Page 2: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

We offer the widest range

of cables on the market for

every kind of installation.

2

Page 3: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

It´s all about reliability.It is always important to choose high quality cables,

especially when it comes to alarms and safety systems.

Even small and seemingly insignificant details can

make a big difference in terms of ease of handling,

functionality and service life.

We have the cables you are looking for

We offer the widest range of cables on the market for

every kind of installation. The cables we supply carry

signals and power supplies. For extra peace of mind

concerning fire protection, our cables are available in

versions meeting specified fire safety requirements in

installations.

Halogen free for greater safety

We have decided only to include halogen free cables

in this brochure. There is a clear trend in that direc-

tion, and there is no longer any reason for not choo-

sing halogen free cables. Halogen free cables offer

many advantages – in particular, they make it easier

to escape the building in the event of fire, generating

substantial savings in the long run.

100 years of experience thrown in

At Nexans we research, develop and manufacture

cables for the whole world. For different environments

and climates. And we’ve been doing it for more than

a hundred years. So when you choose our cables,

they come with a whole lot more – our dedication and

all the experience and expertise we’ve built up over

the decades.

3

Page 4: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Product segments

Fire alarms Detector networks often occupy

large volumes so cables must be

easy to install. Nexans cables are

easy to strip and are optimised

to simplify installation in pipes.

Choose from simple, non twisted

pair cables for small conventional

systems and twisted pair cables

for larger addressable systems.

The cables used in fire alarm

detector networks should normally

have a red sheath. If the cables

are required to keep working

during a fire, you should use

Nexans Alsecure® (see page 12

”Performance during a fire”).

Video surveillance (CCTV) Locally installed CCTV (closed

circuit TV) systems are increasingly

being used as a crime prevention

tool.

In addition to standardized coaxial

cable, Nexans also supplies cables

with separate power supply and a

data cable for IP based solutions

outdoor.

4

Page 5: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Access protection Burglar alarms usually have a sys-

tem of control units and sensors.

Indoor and outdoor entry systems

contain card readers, central units

and computers. The cables used

for intruder protection and entry

control are signal cables with vary-

ing flexibility, shielding and cores.

Alternatively, combination cables

can be used with separate cores

carrying the power supply.

Nexans’ wide range makes it easy

to choose the right cables for the

various components.

Performance during a fireThere is a separate fire class

for cables that are required to

maintain sircuit integrity during a

fire. These cables all have unique

insulation material that is not

damaged like normal cables. This

category can include power supply

cables as well as signal cables.

They should also be flame retar-

dant low fire hazard cables – in

other words they must not give off

any toxic or corrosive gases, and

only small amounts of smoke, if

there is a fire.

The Nexans cables for these appli-

cations are called Alsecure®. The

unique insulation (INFIT™) makes

the cables easy to install while

ensuring they still work during a

fire.

5

Page 6: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

CCTV (Closed Circuit TeleVision) is a locally installed

video surveillance system. A CCTV system consists of

cameras, monitors, transmission elements (cables),

control systems and storage systems. Our range of

halogen free cables for CCTV includes 75 ohm coaxial

cable. We also offer a combined coax and power

supply cable to optimise functionality as well as cable

laying.

For added safety, video sur-veillance cables are also flame retardant and halogen free.

RG 59 LSZHCoaxial cable for video surveillance. The impedance of the

cable: 75 ohm.

Cable Nexans no. Outer diam. Length

RG 59 LSZH 19502641 6,1 mm Bobbin/100

RG 59 LSZH 19502671 6,1 mm Bobbin/500

RG 59 LSZH + 2 x 0,75 mm2

Combined coaxial (75 ohm) and power supply cable (max.

100V) for video surveillance.

Cable Nexans no. Outer diam. Length

RG 59 LSZH + 2 x 0,75 mm2 19503098 9,5 mm Drum/500

Video surveillance (CCTV)

6

Page 7: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

LANmark Industry outlet IP67The LANmark Industry outlet enables the installation of data

outlets in exposed areas as well as outdoor solutions. The

IP67 level of protection is maintained both when the outlet

is nused and when the appropriate IP67 patchcords are

connected. Includes 2 screened category 6 or category 6A

connectors.Cable Nexans no

IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 40060109

IP67 outer with RJ45 cat.6A shielded Snap-in connector, black. 40061009

IP67-IP20 cabling 1,5 m shielded, yellow. Cat.6 RJ45. 40060209

IP67-IP20 cabling 3 m shielded, yellow. Cat.6 RJ45. 40060309

IP67-IP20 cabling 5 m shielded, yellow. Cat.6 RJ45. 40060409

S/FTP Category 6A LSZH + PECategory 6A, 500 MHz Screened data cable. The 4 pairs are

individually foiled and covered with a common braid. Due

to the outer sheath of PE the cable is appropriate for outdoor

installation as well as in exposed areas. It can be installed

indoors when the PE sheet is removed. The cable fulfills cat

6A performance according to EN 50288, IEC 61156 and TIA

568-B

Cable Nexans no Outer diam. Length

Category 6A 4x2x0,5 39020771 8,6 B/500

7

Page 8: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Find out more

about fire safety

and fire classes.

8

Page 9: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

You often won’t know whether you

chose the right cable until after a fire.

People always talk about fire protection but it is important to know what this actually

means in practical terms, and to be certain which flame spread rating you need to

use. For cables, you also need to distinguish between flame spread, fire hazard pro-

perties and fire resistance.

Cables that prevent flame spread

Cables running through building levels and walls are a great way for fires to spread.

So the most important requirement when establishing fire protection is to use cables

with properties that prevent the spread of fire. This is why there are general flame

spread classes, and these must always be defined. Our cables have clearly marked

flame spread classes that are informative and easy to understand.

Halogen free – saving lives and money

Smoke and gases from burning cables often cause the biggest problems for people

and equipment. These problems can be reduced if halogen free cables are used. The

smoke from halogen free cables during a fire is much thinner and does not corrode

metals. This makes it easier to clear smoke from rooms, potentially saving lives. That

is why our cables for alarms and safety systems are halogen free.

Still working during a fire

The most critical cables must also be fire resistant. This means they must be guaran-

teed to work even during a fire. This is made possible by special insulation material,

which is merely altered rather than destroyed by fire. The cable keeps its shape, the

conductors are kept separate and the cable continues to work. These cables are

needed for the fire alarm system itself, but also for the safety lighting guiding people

out of the building, for the smoke extraction fans and for the lifts. Our range includes

fire resistant cables for power supply and for communication.

9

Page 10: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Nexans has a full range of cables for fire alarm systems

The right cable for the right use

Cables for fire alarms are available with either red or

grey sheaths depending on the regulations, aesthe-

tic requirements, etc. In larger addressable systems,

twisted pair cable should be used, KLM-LSZH 2x1.0

mm. If shielded cable is required, Nexans supplies the

KLMA LSZH. If the cables are required to keep working

during a fire, fire resistant Alsecure cables are used.

Installation

The cables for fire alarms are intended for permanent

indoor installation.

ELQRBSignal cable for fire alarms. ELQRB construction is as speci-

fied in SS 424 16 09.

Cable Nexans no. Outer diam. Length

ELQRB 2 x 0,6 mm 18641541 2,9 x 4,2 mm Bobbin/100

ELQRB 2 x 0,6 mm 18641571 2,9 x 4,2 mm Bobbin/500

ELQRB 2 x 1,0 mm 18641641 3,3 x 4,9 mm Bobbin/100

ELQRB 2 x 1,0 mm 18641671 3,3 x 4,9 mm Bobbin/500

ELQRB 4 x 1,0 mm 18641971 5,7 mm Bobbin/500

KLM LSZH 2x1,0Halogen free, pair-twisted signal cable. The cable construc-

tion is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length

KLM LSZH 2x1,0 37159271 5,7 mm Bobbin/500

Fire alarms

KLMA LSZH Halogen free, pair-twisted signal cable. The cable construc-

tion is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length

KLMA LSZH 2x0,8 37158243 5,0 mm Coil/150

KLMA LSZH 2x0,8 37158258 5,0 mm Bobbin/600

KLMA LSZH 4x0,8 37158443 5,5 mm Coil/150

KLMA LSZH 4x0,8 37158458 5,5 mm Bobbin/600

KLM LSZH Halogen free signal cable. The cable construction is, where

applicable, as specified in SFS 2751.Cable Nexans no. Outer diam. Length

KLM LSZH 2x0,8 37156243 4,0 mm Coil/150

KLM LSZH 2x0,8 37156258 4,0 mm Bobbin/600

KLM LSZH 4x0,8 37156443 5,0 mm Coil/150

KLM LSZH 4x0,8 37156458 5,0 mm Bobbin/600

10

Page 11: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Fire resistant cables

maintain circuit integrity

even when affected

by heat or flames.

11

Page 12: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Fire resistant cables are recommended for use in instal-

lations that must maintain circuit integrity during a fire.

Using these cables in important alarm, control, signal

and power supply systems means you can guarantee

they will not be taken down, even if the fire reaches the

cables themselves.

No gases, little smoke

As well as continuing to work during and after a fire,

Nexans fire resistant cables are halogen free so they do

not release any toxic or corrosive gases, and only small

amounts of smoke, if there is a fire. Studies show that

this can save lives and money.

Installation

Examples of systems that must maintain circuit integrity

during a fire include signal and safety systems guiding

people out of the building. Other examples are smoke

extraction fans and lifts. Fire alarm cables, too, if they

pass through areas that are not monitored by detec-

tors, are required to maintain circuit integrity during a

fire.

ALSECURE® PLUS TEL, skärmadFire resistant, twisted pair, shielded telecom and signal cables

for permanent installation indoors or in pipes. Fire perfor-

mance according to IEC60331, IEC 60332-3.Cable Nexans

no.Outer diam.

Length

Alsecure Plus Tel 1 x 2 x 0,9 mm 17541198 6,7 mm Drum/500

Alsecure Plus Tel 2 x 2 x 0,9 mm 17541298 7,4 mm Drum/500

Alsecure Plus Tel 10 x 2 x 0,9 mm 17541698 16 mm Drum/500

Alsecure Plus Tel 2 x 1,5 mm2 +1,5 mm2 17544141 8,0 mm Bobbin/100

ALSECURE® PREMIUMFire resistant, twisted pair, fire alarm cables for permanent

installation indoors or in pipes. Fire performance according

to IEC60331, IEC 60332-3. Cable Nexans

no.Outer diam.

Length

Alsecure Premium 2 x 1,0 mm 17542171 6,2 mm Bobbin/500

Alsecure Premium 10 x 2 x 1,0 mm 17542698 17,0 mm Drum/500

ALSECURE® PLUS 0,6/1kV, FRHFFire resistant power cable with round or sector shaped, stran-

ded, soldered copper conductor and concentric shielding.

For permanent installation in all areas. Fire performance

according to IEC 60331, IEC 60332-3.Cable Nexans no. Outer diam. Length

Alsecure Plus 1kV 2 x 1,5/1,5 27005698 11,9 mm Drum/500

Alsecure Plus 1kV 3 x 1,5/1,5 27004498 12,5 mm Drum/500

Alsecure Plus 1kV 4 x 1,5/1,5 27005798 15,2 mm Drum/500

Alsecure Plus 1kV 2 x 2,5/2,5 27005898 14,7 mm Drum/500

Alsecure Plus 1kV 3 x 2,5/2,5 27005998 15,2 mm Drum/500

Alsecure Plus 1kV 4 x 2,5/2,5 27030198 16,4 mm Drum/500

Alsecure Plus 1kV 4 x 6/6 35123998 18,1 mm Drum/500

Alsecure Plus 1kV 4 x 10/10 35124198 22,0 mm Drum/500

Alsecure Plus 1kV 4 x 16/16 35124398 24,2 mm Drum/500

Alsecure Plus 1kV 4 x 25/16 35124598 26,0 mm Drum/500

Alsecure Plus 1kV 4 x 35/16 35124798 30,0 mm Drum/500

Alsecure Plus 1kV 4 x 50/25 35126598 35,0 mm Drum/500

Alsecure Plus 1kV 4 x 70/35 35125198 36,0 mm Drum/500

Alsecure Plus 1kV 4 x 95/50 35125398 41,0 mm Drum/500

Alsecure Plus 1kV 4 x 120/70 35125598 42,2 mm Drum/500

Alsecure Plus 1kV 4 x 150/70 35125798 49,0 mm Drum/500

Alsecure Plus 1kV 4 x 185/95 35125898 52,0 mm Drum/500

Alsecure Plus 1kV 4 x 240/120 35126198 60,0 mm Drum/500

Performance during a fire

12

Page 13: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Another important fire safety property is low smoke development.

ALSECURE® PREMIUM 300/500VFire resistant, halogen free control cables with round, solid

copper conductors. This cable is designed for permanent

installation on cable ladders, directly on walls or in pipes or

ducting. Applications include emergency lighting, fire alarm

systems and control systems. Fire performance according to

IEC60331, IEC 60332-3.Cable Nexans no. Outer diam. Length

Alsecure Premium 3G1,5 27010098 8,0 mm Drum/500

Alsecure Premium 3G2,5 27010198 10,0 mm Drum/500

Alsecure Premium 4G1,5 27010298 9,5 mm Drum/500

Alsecure Premium 5G1,5 27010398 10,0 mm Drum/500

Alsecure Premium 5G2,5 27010598 12,0 mm Drum/500

ALSECURE® PLUS STYR 300/500VFire resistant, halogen free, unshielded installation cables

with round, solid copper conductors. For permanent installa-

tion on cable ladders, directly on walls or in pipes or ducting.

Fire performance according to IEC60331, IEC 60332-3.

Cable Nesans no. Outer diam. Length

Alsecure Plus Styr 7G1,5 27001498 14 mm Drum/500

Alsecure Plus Styr 12G1,5 27001198 19,5 mm Drum/500

Alsecure Plus Styr 19G1,5 27004198 22,5 mm Drum/500

Alsecure Plus Styr 7G2,5 27008298 16 mm Drum/500

13

Page 14: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Access protection

Our cables for intruder alarms and entry systems

come in a range of types. We have shielded as well as

unshielded twisted pair cables – up to ten pairs. We

also offer flexible single wire cables with four to 12

cores. Combination cables are also available for entry

systems – cables with twisted pair signal elements and

power supply elements (max 100 V).

MHS LSZHPair-twisted, shielded communication cable with halogen

free, flame retardant sheath. The cable construction is, where

applicable, as specified in SFS 5739.

Cable Nexans no. Outer diam. Length

MHS LSZH 1x4x0,5 38565040 5,0 Coil/100

MHS LSZH 1x4x0,5 38565098 5,0 Drum/1000

MHS LSZH 3x2x0,5 38565145 6,0 Coil/200

MHS LSZH 3x2x0,5 38565198 6,0 Drum/1000

MHS LSZH 5x2x0,5 38565243 6,5 Coil/150

MHS LSZH 5x2x0,5 38565298 6,5 Drum/1000

MHS LSZH 10x2x0,5 38565340 8,5 Coil/100

MHS LSZH 10x2x0,5 38565398 8,5 Drum/1000

ELQXB (halogen free EKKX)Twisted pair cable for intruder alarms and entry systems.

Cable Nexans no. Outer diam. Length

ELQXB 1 x 4 x 0,5 mm 17501041 3,4 mm Bobbin/100

ELQXB 1 x 4 x 0,5 mm 17501071 3,4 mm Bobbin/500

ELQXB 2 x 2 x 0,5 mm 17500241 4,5 mm Bobbin/100

ELQXB 2 x 2 x 0,5 mm 17500271 4,5 mm Bobbin/500

ELQXB 4 x 2 x 0,5 mm 17501141 5,3 mm Bobbin/100

ELQXB 4 x 2 x 0,5 mm 17501171 5,3 mm Bobbin/500

ELQXB 6 x 2 x 0,5 mm 17501241 6,0 mm Bobbin/100

ELQXB 6 x 2 x 0,5 mm 17501271 6,0 mm Bobbin/500

ELQXB 10 x 2 x 0,5 mm 17501341 7,5 mm Bobbin/100

ELQXB 10 x 2 x 0,5 mm 17501371 7,5 mm Bobbin/500

FQQXBFlexible signal and alarm cables for intruder alarms and

access control systems. Cable Nexans no. Outer diam. Length

FQQXB 4 x 0,22 mm2 17523141 3,7 mm Bobbin/100

FQQXB 4 x 0,22 mm2 17523171 3,7 mm Bobbin/500

FQQXB 6 x 0,22 mm2 17523241 4,2 mm Bobbin/100

FQQXB 6 x 0,22 mm2 17523271 4,2 mm Bobbin/500

FQQXB 8 x 0,22 mm2 17523341 4,7 mm Bobbin/100

FQQXB 8 x 0,22 mm2 17523371 4,7 mm Bobbin/500

FQQXB 12 x 0,22 mm2 17523441 5,4 mm Bobbin/100

FQQXB 12 x 0,22 mm2 17523471 5,4 mm Bobbin/500

FQQXB 4 x 2 x 0,22 mm2 17524271 5,3 mm Bobbin/500

FQQXB 10 x 2 x 0,22 mm2 17524898 8,0 mm Drum/500

14

Page 15: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

FLAQQBRCombined power supply and signal cables for intruder

alarms and entry systems. The twisted pair signal element is

unshielded.Cable Nexans

no.Outer diam.

Length

FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033341 6,5 mm Bobbin/100

FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033371 6,5 mm Bobbin/500

FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17515198 8,0 mm Drum/500

FLAQQBR 3 x 1,0 + 2 x 2 x 0,6 mm 17034298 8,5 mm Drum/500

FLQQBRCombined power supply and signal cables for intruder

alarms and entry systems. The twisted pair signal element is

unshielded.Cable Nexans

no.Outer diam.

Length

FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm2 17513198 8,5 mm Drum/500

FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513041 6,5 mm Bobbin/100

FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513071 6,5 mm Bobbin/500

FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17513271 7,5 mm Bobbin/500

We have the exa

ct

cable that complie

s

to all your needs

.

15

Page 16: Cables for alarm- and safety systems - Nexans for alarm- and safety systems_… · Cables for alarm- and safety systems Flexible and ions, for decades. ange ket for ion. 2. It´s

Nexans Sweden AB, 514 81 Grimsås, www.nexans.se

Our cables for alarm- and safety systems compared with others.

Learn more about what significates our cables

for alarm- and safety systems at www.nexans.se