Cables for alarm- and safety systems
Flexible and
safe solutions,
for decades.
We offer the widest range
of cables on the market for
every kind of installation.
2
It´s all about reliability.It is always important to choose high quality cables,
especially when it comes to alarms and safety systems.
Even small and seemingly insignificant details can
make a big difference in terms of ease of handling,
functionality and service life.
We have the cables you are looking for
We offer the widest range of cables on the market for
every kind of installation. The cables we supply carry
signals and power supplies. For extra peace of mind
concerning fire protection, our cables are available in
versions meeting specified fire safety requirements in
installations.
Halogen free for greater safety
We have decided only to include halogen free cables
in this brochure. There is a clear trend in that direc-
tion, and there is no longer any reason for not choo-
sing halogen free cables. Halogen free cables offer
many advantages – in particular, they make it easier
to escape the building in the event of fire, generating
substantial savings in the long run.
100 years of experience thrown in
At Nexans we research, develop and manufacture
cables for the whole world. For different environments
and climates. And we’ve been doing it for more than
a hundred years. So when you choose our cables,
they come with a whole lot more – our dedication and
all the experience and expertise we’ve built up over
the decades.
3
Product segments
Fire alarms Detector networks often occupy
large volumes so cables must be
easy to install. Nexans cables are
easy to strip and are optimised
to simplify installation in pipes.
Choose from simple, non twisted
pair cables for small conventional
systems and twisted pair cables
for larger addressable systems.
The cables used in fire alarm
detector networks should normally
have a red sheath. If the cables
are required to keep working
during a fire, you should use
Nexans Alsecure® (see page 12
”Performance during a fire”).
Video surveillance (CCTV) Locally installed CCTV (closed
circuit TV) systems are increasingly
being used as a crime prevention
tool.
In addition to standardized coaxial
cable, Nexans also supplies cables
with separate power supply and a
data cable for IP based solutions
outdoor.
4
Access protection Burglar alarms usually have a sys-
tem of control units and sensors.
Indoor and outdoor entry systems
contain card readers, central units
and computers. The cables used
for intruder protection and entry
control are signal cables with vary-
ing flexibility, shielding and cores.
Alternatively, combination cables
can be used with separate cores
carrying the power supply.
Nexans’ wide range makes it easy
to choose the right cables for the
various components.
Performance during a fireThere is a separate fire class
for cables that are required to
maintain sircuit integrity during a
fire. These cables all have unique
insulation material that is not
damaged like normal cables. This
category can include power supply
cables as well as signal cables.
They should also be flame retar-
dant low fire hazard cables – in
other words they must not give off
any toxic or corrosive gases, and
only small amounts of smoke, if
there is a fire.
The Nexans cables for these appli-
cations are called Alsecure®. The
unique insulation (INFIT™) makes
the cables easy to install while
ensuring they still work during a
fire.
5
CCTV (Closed Circuit TeleVision) is a locally installed
video surveillance system. A CCTV system consists of
cameras, monitors, transmission elements (cables),
control systems and storage systems. Our range of
halogen free cables for CCTV includes 75 ohm coaxial
cable. We also offer a combined coax and power
supply cable to optimise functionality as well as cable
laying.
For added safety, video sur-veillance cables are also flame retardant and halogen free.
RG 59 LSZHCoaxial cable for video surveillance. The impedance of the
cable: 75 ohm.
Cable Nexans no. Outer diam. Length
RG 59 LSZH 19502641 6,1 mm Bobbin/100
RG 59 LSZH 19502671 6,1 mm Bobbin/500
RG 59 LSZH + 2 x 0,75 mm2
Combined coaxial (75 ohm) and power supply cable (max.
100V) for video surveillance.
Cable Nexans no. Outer diam. Length
RG 59 LSZH + 2 x 0,75 mm2 19503098 9,5 mm Drum/500
Video surveillance (CCTV)
6
LANmark Industry outlet IP67The LANmark Industry outlet enables the installation of data
outlets in exposed areas as well as outdoor solutions. The
IP67 level of protection is maintained both when the outlet
is nused and when the appropriate IP67 patchcords are
connected. Includes 2 screened category 6 or category 6A
connectors.Cable Nexans no
IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 40060109
IP67 outer with RJ45 cat.6A shielded Snap-in connector, black. 40061009
IP67-IP20 cabling 1,5 m shielded, yellow. Cat.6 RJ45. 40060209
IP67-IP20 cabling 3 m shielded, yellow. Cat.6 RJ45. 40060309
IP67-IP20 cabling 5 m shielded, yellow. Cat.6 RJ45. 40060409
S/FTP Category 6A LSZH + PECategory 6A, 500 MHz Screened data cable. The 4 pairs are
individually foiled and covered with a common braid. Due
to the outer sheath of PE the cable is appropriate for outdoor
installation as well as in exposed areas. It can be installed
indoors when the PE sheet is removed. The cable fulfills cat
6A performance according to EN 50288, IEC 61156 and TIA
568-B
Cable Nexans no Outer diam. Length
Category 6A 4x2x0,5 39020771 8,6 B/500
7
Find out more
about fire safety
and fire classes.
8
You often won’t know whether you
chose the right cable until after a fire.
People always talk about fire protection but it is important to know what this actually
means in practical terms, and to be certain which flame spread rating you need to
use. For cables, you also need to distinguish between flame spread, fire hazard pro-
perties and fire resistance.
Cables that prevent flame spread
Cables running through building levels and walls are a great way for fires to spread.
So the most important requirement when establishing fire protection is to use cables
with properties that prevent the spread of fire. This is why there are general flame
spread classes, and these must always be defined. Our cables have clearly marked
flame spread classes that are informative and easy to understand.
Halogen free – saving lives and money
Smoke and gases from burning cables often cause the biggest problems for people
and equipment. These problems can be reduced if halogen free cables are used. The
smoke from halogen free cables during a fire is much thinner and does not corrode
metals. This makes it easier to clear smoke from rooms, potentially saving lives. That
is why our cables for alarms and safety systems are halogen free.
Still working during a fire
The most critical cables must also be fire resistant. This means they must be guaran-
teed to work even during a fire. This is made possible by special insulation material,
which is merely altered rather than destroyed by fire. The cable keeps its shape, the
conductors are kept separate and the cable continues to work. These cables are
needed for the fire alarm system itself, but also for the safety lighting guiding people
out of the building, for the smoke extraction fans and for the lifts. Our range includes
fire resistant cables for power supply and for communication.
9
Nexans has a full range of cables for fire alarm systems
The right cable for the right use
Cables for fire alarms are available with either red or
grey sheaths depending on the regulations, aesthe-
tic requirements, etc. In larger addressable systems,
twisted pair cable should be used, KLM-LSZH 2x1.0
mm. If shielded cable is required, Nexans supplies the
KLMA LSZH. If the cables are required to keep working
during a fire, fire resistant Alsecure cables are used.
Installation
The cables for fire alarms are intended for permanent
indoor installation.
ELQRBSignal cable for fire alarms. ELQRB construction is as speci-
fied in SS 424 16 09.
Cable Nexans no. Outer diam. Length
ELQRB 2 x 0,6 mm 18641541 2,9 x 4,2 mm Bobbin/100
ELQRB 2 x 0,6 mm 18641571 2,9 x 4,2 mm Bobbin/500
ELQRB 2 x 1,0 mm 18641641 3,3 x 4,9 mm Bobbin/100
ELQRB 2 x 1,0 mm 18641671 3,3 x 4,9 mm Bobbin/500
ELQRB 4 x 1,0 mm 18641971 5,7 mm Bobbin/500
KLM LSZH 2x1,0Halogen free, pair-twisted signal cable. The cable construc-
tion is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length
KLM LSZH 2x1,0 37159271 5,7 mm Bobbin/500
Fire alarms
KLMA LSZH Halogen free, pair-twisted signal cable. The cable construc-
tion is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length
KLMA LSZH 2x0,8 37158243 5,0 mm Coil/150
KLMA LSZH 2x0,8 37158258 5,0 mm Bobbin/600
KLMA LSZH 4x0,8 37158443 5,5 mm Coil/150
KLMA LSZH 4x0,8 37158458 5,5 mm Bobbin/600
KLM LSZH Halogen free signal cable. The cable construction is, where
applicable, as specified in SFS 2751.Cable Nexans no. Outer diam. Length
KLM LSZH 2x0,8 37156243 4,0 mm Coil/150
KLM LSZH 2x0,8 37156258 4,0 mm Bobbin/600
KLM LSZH 4x0,8 37156443 5,0 mm Coil/150
KLM LSZH 4x0,8 37156458 5,0 mm Bobbin/600
10
Fire resistant cables
maintain circuit integrity
even when affected
by heat or flames.
11
Fire resistant cables are recommended for use in instal-
lations that must maintain circuit integrity during a fire.
Using these cables in important alarm, control, signal
and power supply systems means you can guarantee
they will not be taken down, even if the fire reaches the
cables themselves.
No gases, little smoke
As well as continuing to work during and after a fire,
Nexans fire resistant cables are halogen free so they do
not release any toxic or corrosive gases, and only small
amounts of smoke, if there is a fire. Studies show that
this can save lives and money.
Installation
Examples of systems that must maintain circuit integrity
during a fire include signal and safety systems guiding
people out of the building. Other examples are smoke
extraction fans and lifts. Fire alarm cables, too, if they
pass through areas that are not monitored by detec-
tors, are required to maintain circuit integrity during a
fire.
ALSECURE® PLUS TEL, skärmadFire resistant, twisted pair, shielded telecom and signal cables
for permanent installation indoors or in pipes. Fire perfor-
mance according to IEC60331, IEC 60332-3.Cable Nexans
no.Outer diam.
Length
Alsecure Plus Tel 1 x 2 x 0,9 mm 17541198 6,7 mm Drum/500
Alsecure Plus Tel 2 x 2 x 0,9 mm 17541298 7,4 mm Drum/500
Alsecure Plus Tel 10 x 2 x 0,9 mm 17541698 16 mm Drum/500
Alsecure Plus Tel 2 x 1,5 mm2 +1,5 mm2 17544141 8,0 mm Bobbin/100
ALSECURE® PREMIUMFire resistant, twisted pair, fire alarm cables for permanent
installation indoors or in pipes. Fire performance according
to IEC60331, IEC 60332-3. Cable Nexans
no.Outer diam.
Length
Alsecure Premium 2 x 1,0 mm 17542171 6,2 mm Bobbin/500
Alsecure Premium 10 x 2 x 1,0 mm 17542698 17,0 mm Drum/500
ALSECURE® PLUS 0,6/1kV, FRHFFire resistant power cable with round or sector shaped, stran-
ded, soldered copper conductor and concentric shielding.
For permanent installation in all areas. Fire performance
according to IEC 60331, IEC 60332-3.Cable Nexans no. Outer diam. Length
Alsecure Plus 1kV 2 x 1,5/1,5 27005698 11,9 mm Drum/500
Alsecure Plus 1kV 3 x 1,5/1,5 27004498 12,5 mm Drum/500
Alsecure Plus 1kV 4 x 1,5/1,5 27005798 15,2 mm Drum/500
Alsecure Plus 1kV 2 x 2,5/2,5 27005898 14,7 mm Drum/500
Alsecure Plus 1kV 3 x 2,5/2,5 27005998 15,2 mm Drum/500
Alsecure Plus 1kV 4 x 2,5/2,5 27030198 16,4 mm Drum/500
Alsecure Plus 1kV 4 x 6/6 35123998 18,1 mm Drum/500
Alsecure Plus 1kV 4 x 10/10 35124198 22,0 mm Drum/500
Alsecure Plus 1kV 4 x 16/16 35124398 24,2 mm Drum/500
Alsecure Plus 1kV 4 x 25/16 35124598 26,0 mm Drum/500
Alsecure Plus 1kV 4 x 35/16 35124798 30,0 mm Drum/500
Alsecure Plus 1kV 4 x 50/25 35126598 35,0 mm Drum/500
Alsecure Plus 1kV 4 x 70/35 35125198 36,0 mm Drum/500
Alsecure Plus 1kV 4 x 95/50 35125398 41,0 mm Drum/500
Alsecure Plus 1kV 4 x 120/70 35125598 42,2 mm Drum/500
Alsecure Plus 1kV 4 x 150/70 35125798 49,0 mm Drum/500
Alsecure Plus 1kV 4 x 185/95 35125898 52,0 mm Drum/500
Alsecure Plus 1kV 4 x 240/120 35126198 60,0 mm Drum/500
Performance during a fire
12
Another important fire safety property is low smoke development.
ALSECURE® PREMIUM 300/500VFire resistant, halogen free control cables with round, solid
copper conductors. This cable is designed for permanent
installation on cable ladders, directly on walls or in pipes or
ducting. Applications include emergency lighting, fire alarm
systems and control systems. Fire performance according to
IEC60331, IEC 60332-3.Cable Nexans no. Outer diam. Length
Alsecure Premium 3G1,5 27010098 8,0 mm Drum/500
Alsecure Premium 3G2,5 27010198 10,0 mm Drum/500
Alsecure Premium 4G1,5 27010298 9,5 mm Drum/500
Alsecure Premium 5G1,5 27010398 10,0 mm Drum/500
Alsecure Premium 5G2,5 27010598 12,0 mm Drum/500
ALSECURE® PLUS STYR 300/500VFire resistant, halogen free, unshielded installation cables
with round, solid copper conductors. For permanent installa-
tion on cable ladders, directly on walls or in pipes or ducting.
Fire performance according to IEC60331, IEC 60332-3.
Cable Nesans no. Outer diam. Length
Alsecure Plus Styr 7G1,5 27001498 14 mm Drum/500
Alsecure Plus Styr 12G1,5 27001198 19,5 mm Drum/500
Alsecure Plus Styr 19G1,5 27004198 22,5 mm Drum/500
Alsecure Plus Styr 7G2,5 27008298 16 mm Drum/500
13
Access protection
Our cables for intruder alarms and entry systems
come in a range of types. We have shielded as well as
unshielded twisted pair cables – up to ten pairs. We
also offer flexible single wire cables with four to 12
cores. Combination cables are also available for entry
systems – cables with twisted pair signal elements and
power supply elements (max 100 V).
MHS LSZHPair-twisted, shielded communication cable with halogen
free, flame retardant sheath. The cable construction is, where
applicable, as specified in SFS 5739.
Cable Nexans no. Outer diam. Length
MHS LSZH 1x4x0,5 38565040 5,0 Coil/100
MHS LSZH 1x4x0,5 38565098 5,0 Drum/1000
MHS LSZH 3x2x0,5 38565145 6,0 Coil/200
MHS LSZH 3x2x0,5 38565198 6,0 Drum/1000
MHS LSZH 5x2x0,5 38565243 6,5 Coil/150
MHS LSZH 5x2x0,5 38565298 6,5 Drum/1000
MHS LSZH 10x2x0,5 38565340 8,5 Coil/100
MHS LSZH 10x2x0,5 38565398 8,5 Drum/1000
ELQXB (halogen free EKKX)Twisted pair cable for intruder alarms and entry systems.
Cable Nexans no. Outer diam. Length
ELQXB 1 x 4 x 0,5 mm 17501041 3,4 mm Bobbin/100
ELQXB 1 x 4 x 0,5 mm 17501071 3,4 mm Bobbin/500
ELQXB 2 x 2 x 0,5 mm 17500241 4,5 mm Bobbin/100
ELQXB 2 x 2 x 0,5 mm 17500271 4,5 mm Bobbin/500
ELQXB 4 x 2 x 0,5 mm 17501141 5,3 mm Bobbin/100
ELQXB 4 x 2 x 0,5 mm 17501171 5,3 mm Bobbin/500
ELQXB 6 x 2 x 0,5 mm 17501241 6,0 mm Bobbin/100
ELQXB 6 x 2 x 0,5 mm 17501271 6,0 mm Bobbin/500
ELQXB 10 x 2 x 0,5 mm 17501341 7,5 mm Bobbin/100
ELQXB 10 x 2 x 0,5 mm 17501371 7,5 mm Bobbin/500
FQQXBFlexible signal and alarm cables for intruder alarms and
access control systems. Cable Nexans no. Outer diam. Length
FQQXB 4 x 0,22 mm2 17523141 3,7 mm Bobbin/100
FQQXB 4 x 0,22 mm2 17523171 3,7 mm Bobbin/500
FQQXB 6 x 0,22 mm2 17523241 4,2 mm Bobbin/100
FQQXB 6 x 0,22 mm2 17523271 4,2 mm Bobbin/500
FQQXB 8 x 0,22 mm2 17523341 4,7 mm Bobbin/100
FQQXB 8 x 0,22 mm2 17523371 4,7 mm Bobbin/500
FQQXB 12 x 0,22 mm2 17523441 5,4 mm Bobbin/100
FQQXB 12 x 0,22 mm2 17523471 5,4 mm Bobbin/500
FQQXB 4 x 2 x 0,22 mm2 17524271 5,3 mm Bobbin/500
FQQXB 10 x 2 x 0,22 mm2 17524898 8,0 mm Drum/500
14
FLAQQBRCombined power supply and signal cables for intruder
alarms and entry systems. The twisted pair signal element is
unshielded.Cable Nexans
no.Outer diam.
Length
FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033341 6,5 mm Bobbin/100
FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033371 6,5 mm Bobbin/500
FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17515198 8,0 mm Drum/500
FLAQQBR 3 x 1,0 + 2 x 2 x 0,6 mm 17034298 8,5 mm Drum/500
FLQQBRCombined power supply and signal cables for intruder
alarms and entry systems. The twisted pair signal element is
unshielded.Cable Nexans
no.Outer diam.
Length
FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm2 17513198 8,5 mm Drum/500
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513041 6,5 mm Bobbin/100
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513071 6,5 mm Bobbin/500
FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17513271 7,5 mm Bobbin/500
We have the exa
ct
cable that complie
s
to all your needs
.
15