CABLES FOR ALARM AND SAFETY SYSTEMS
2
3
IT´S ALL ABOUT RELIABILITY.It is always important to choose high quality cables,
especially when it comes to alarms and safety systems.
Even small and seemingly insignificant details can make
a big difference in terms of ease of handling,
functionality and service life.
We have the cables you are looking for
We offer the widest range of cables on the market for every
kind of installation. The cables we supply carry signals and
power supplies. For extra peace of mind concerning fire
protection, our cables are available in versions meeting
specified fire safety requirements in installations.
Halogen free for greater safety
We have decided only to include halogen free cables in this
brochure. There is a clear trend in that direction, and there is
no longer any reason for not choosing halogen free cables.
Halogen free cables offer many advantages – in particular,
they make it easier to escape the building in the event of fire,
generating substantial savings in the long run.
100 years of experience thrown in
At Nexans we research, develop and manufacture cables for
the whole world. For different environments and climates. And
we’ve been doing it for more than a hundred years. So when
you choose our cables, they come with a whole lot more – our
dedication and all the experience and expertise we’ve built up
over the decades.
4
PRODUCT SEGMENTS
FIRE ALARMS Detector networks often occupy
large volumes so cables must be
easy to install. Nexans cables are
easy to strip and are optimised
to simplify installation in pipes.
Choose from simple, non twisted
pair cables for small conventional
systems and twisted pair cables for
larger addressable systems. The
cables used in fire alarm detector
networks should normally have a
red sheath. If the cables are
required to keep working during
a fire, you should use Nexans
Alsecure® (see page 12
”Performance during a fire”).
VIDEO SURVEILLANCE (CCTV) Locally installed CCTV (closed circuit
TV) systems are increasingly being
used as a crime prevention tool.
4
5
ACCESS PROTECTION Burglar alarms usually have a
system of control units and sensors.
Indoor and outdoor entry systems
contain card readers, central units
and computers. The cables used for
intruder protection and entry control
are signal cables with
varying flexibility, shielding and
cores. Alternatively, combination
cables can be used with separate
cores carrying the power supply.
Nexans’ wide range makes it easy
to choose the right cables for the
various components.
PERFORMANCE DURING A FIREThere is a separate fire class for
cables that are required to maintain
sircuit integrity during a fire. These
cables all have unique insulation
material that is not damaged like
normal cables. This category can
include power supply cables as well
as signal cables. They should also
be flame retardant low fire hazard
cables – in other words they must
not give off any toxic or corrosive
gases, and only small amounts of
smoke, if there is a fire.
The Nexans cables for these
applications are called Alsecure®.
The unique insulation (INFIT™)
makes the cables easy to install
while ensuring they still work during
a fire.
5
6
CCTV (Closed Circuit TeleVision) is a locally installed video
surveillance system. A CCTV system consists of cameras,
monitors, transmission elements (cables), control systems and
storage systems. Our range of halogen free cables for CCTV
includes 75 ohm coaxial cable.
The S/FTP Category 6A cable together with the
IP67 outlet box offers a safe and robust solution for
solutions for IP network cameras outdoor and in harsh
environments.
RG 59 LSZHCoaxial cable for video surveillance. The impedance of the
cable: 75 ohm.
Cable STK no. Outer diam. Length
RG 59 LSZH 0235704 6,1 mm Bobbin/100
RG 59 LSZH 0235708 6,1 mm Bobbin/500
VIDEO SURVEILLANCE (CCTV)
7
LANmark Industry outlet IP67The LANmark Industry outlet enables the installation of data
outlets in exposed areas as well as outdoor solutions. The IP67
level of protection is maintained both when the outlet is unused
and when the appropriate IP67 patchcords are connected.
Includes 2 screened category 6 or category 6A connectors.
Cable STK no.
IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 7280048
S/FTP Category 6A LSZH + PECategory 6A, 500 MHz Screened data cable. The 4 pairs are
individually foiled and covered with a common braid. Due to
the outer sheath of PE the cable is appropriate for outdoor
installation as well as in exposed areas. It can be installed
indoors when the PE sheet is removed. The cable fulfills cat 6A
performance according to EN 50288, IEC 61156
and TIA 568-B
Cable STK no. Outer diam. Length
Category 6A 4x2x0,5 0233347 8,6 mm B/500
8
9
YOU OFTEN WON’T KNOW WHETHER YOU CHOSE THE RIGHT CABLE UNTIL AFTER A FIRE.
People always talk about fire protection but it is important to know what this actually
means in practical terms, and to be certain which flame spread rating you need to use.
For cables, you also need to distinguish between flame spread, fire hazard properties and
fire resistance.
Cables that prevent flame spread
Cables running through building levels and walls are a great way for fires to spread. So
the most important requirement when establishing fire protection is to use cables with
properties that prevent the spread of fire. This is why there are general flame spread
classes, and these must always be defined. Our cables have clearly marked flame spread
classes that are informative and easy to understand.
Halogen free – saving lives and money
Smoke and gases from burning cables often cause the biggest problems for people and
equipment. These problems can be reduced if halogen free cables are used. The smoke
from halogen free cables during a fire is much thinner and does not corrode metals.
This makes it easier to clear smoke from rooms, potentially saving lives. That is why our
cables for alarms and safety systems are halogen free.
Still working during a fire
The most critical cables must also be fire resistant. This means they must be guaranteed
to work even during a fire. This is made possible by special insulation material, which is
merely altered rather than destroyed by fire. The cable keeps its shape, the conductors
are kept separate and the cable continues to work. These cables are needed for the fire
alarm system itself, but also for the safety lighting guiding people out of the building, for
the smoke extraction fans and for the lifts. Our range includes fire resistant cables for
power supply and for communication.
10
Nexans has a full range of cables for fire alarm systems
The right cable for the right use
Cables for fire alarms are available with either red or grey
sheaths depending on the regulations, aesthetic requirements,
etc. In larger addressable systems, twisted pair cable should
be used, KLM-LSZH 2x1.0 mm. If shielded cable is required,
Nexans supplies the KLMA LSZH. If the cables are required to
keep working during a fire, fire resistant Alsecure cables are
used.
Installation
The cables for fire alarms are intended for permanent indoor
installation.
KLM Easy™ LSZH 2x1,0Halogen free, pair-twisted signal cable. The cable construction
is as specified in SS 424 16 54 (EQQYB).
Cable STK no. Outer diam. Length
KLM Easy™ LSZH 2x1,0 0233358 5,7 mm Bobbin/500
KLM Easy™ LSZH 2x1,0 0235713 5,7 mm Bobbin/100
FIRE ALARMS
KLMA LSZH Halogen free, pair-twisted signal cable. The cable construction
is as specified in SFS 2751.
Cable STK no. Outer diam. Length
KLMA LSZH 2x0,8 0233370 5,0 mm Coil/150
KLMA LSZH 2x0,8 0233369 5,0 mm Bobbin/600
KLMA LSZH 4x0,8 0233378 5,5 mm Coil/150
KLMA LSZH 4x0,8 0233374 5,5 mm Bobbin/600
KLM LSZH Halogen free signal cable. The cable construction is, where
applicable, as specified in SFS 2751.
Cable STK no. Outer diam. Length
KLM LSZH 2x0,8 0233362 4,0 mm Coil/150
KLM LSZH 2x0,8 0233360 4,0 mm Bobbin/600
KLM LSZH 4x0,8 0233368 5,0 mm Coil/150
KLM LSZH 4x0,8 0233364 5,0 mm Bobbin/600
11
12
Fire resistant cables are recommended for use in installations
that must maintain circuit integrity during a fire. Using these
cables in important alarm, control, signal and power supply
systems means you can guarantee they will not be taken down,
even if the fire reaches the cables themselves.
No gases, little smoke
As well as continuing to work during and after a fire, Nexans fire
resistant cables are halogen free so they do not release any toxic
or corrosive gases, and only small amounts of smoke, if there is
a fire. Studies show that this can save lives and money.
Installation
Examples of systems that must maintain circuit integrity during a
fire include signal and safety systems guiding people out of the
building. Other examples are smoke extraction fans and lifts.
Fire alarm cables, too, if they pass through areas that are not
monitored by detectors, are required to maintain circuit integrity
during a fire.
ALSECURE® PREMIUMFire resistant, twisted pair, fire alarm cables for permanent
installation indoors or in pipes. Fire performance according to
IEC60331, IEC 60332-3.
Cable STK no. Outer diam. Length
Alsecure Premium 2 x 1,0 mm 0235747 6,2 mm Bobbin/500
Alsecure Premium 10 x 2 x 1,0 mm 0235748 17,0 mm Drum/500
ALSECURE® PLUS 0,6/1kV, FRHFFire resistant power cable with round or sector shaped,
stranded, soldered copper conductor and concentric shielding.
For permanent installation in all areas. Fire performance
according to IEC 60331, IEC 60332-3.
Cable STK no. Outer diam. Length
Alsecure Plus 1 kV 2 x 1,5/1,5 0638502 11,9 mm Drum/500
Alsecure Plus 1 kV 3 x 1,5/1,5 0638503 12,5 mm Drum/500
Alsecure Plus 1 kV 4 x 1,5/1,5 0638504 15,2 mm Drum/500
Alsecure Plus 1 kV 2 x 2,5/2,5 0638506 14,7 mm Drum/500
Alsecure Plus 1 kV 3 x 2,5/2,5 0638507 15,2 mm Drum/500
Alsecure Plus 1 kV 4 x 2,5/2,5 0638508 16,4 mm Drum/500
Alsecure Plus 1 kV 4 x 6/6 0638510 18,1 mm Drum/500
Alsecure Plus 1 kV 4 x 10/10 0638511 22,0 mm Drum/500
Alsecure Plus 1 kV 4 x 16/16 0638512 24,2 mm Drum/500
Alsecure Plus 1 kV 4 x 25/16 0638513 26,0 mm Drum/500
Alsecure Plus 1 kV 4 x 35/16 0638514 30,0 mm Drum/500
Alsecure Plus 1 kV 4 x 50/25 0638516 35,0 mm Drum/500
Alsecure Plus 1 kV 4 x 70/35 0638517 36,0 mm Drum/500
Alsecure Plus 1 kV 4 x 95/50 0638518 41,0 mm Drum/500
Alsecure Plus 1 kV 4 x 120/70 0638519 42,2 mm Drum/500
Alsecure Plus 1 kV 4 x 150/70 0638520 49,0 mm Drum/500
Alsecure Plus 1 kV 4 x 185/95 0638521 52,0 mm Drum/500
Alsecure Plus 1 kV 4 x 240/120 0638522 60,0 mm Drum/500
PERFORMANCE DURING A FIRE
13
ALSECURE® PREMIUM 300/500VFire resistant, halogen free control cables with round, solid
copper conductors. This cable is designed for permanent
installation on cable ladders, directly on walls or in pipes or
ducting. Applications include emergency lighting, fire alarm
systems and control systems. Fire performance according to
IEC60331, IEC 60332-3.
Cable STK no. Outer diam. Length
Alsecure Premium 3G1,5 0603470 8,0 mm Drum/500
Alsecure Premium 3G2,5 0603471 10,0 mm Drum/500
Alsecure Premium 4G1,5 0603472 9,5 mm Drum/500
Alsecure Premium 5G1,5 0603473 10,0 mm Drum/500
Alsecure Premium 5G2,5 0603474 12,0 mm Drum/500
14
ACCESS PROTECTIONOur cables for intruder alarms and entry systems come in a
range of types. We have shielded as well as unshielded twisted
pair cables – up to hundred pairs. We also offer flexible single
wire cables with 4 to 12 cores. Combination cables are also
available for entry systems – cables with twisted pair signal
elements and power supply elements (max 100 V).
Fire performance according to CPR cluss Dca-s2,d2,a2.
MHS LSZHPair-twisted, shielded communication cable with halogen free,
flame retardant sheath. The cable construction is, where
applicable, as specified in SFS 5739.
Cable STK no. Outer diam. Length
MHS LSZH 1x4x0,5 0233380 5,0 Coil/100
MHS LSZH 1x4x0,5 0233379 5,0 Drum/1000
MHS LSZH 3x2x0,5 0233382 6,0 Coil/200
MHS LSZH 3x2x0,5 0233381 6,0 Drum/1000
MHS LSZH 5x2x0,5 0233384 6,5 Coil/150
MHS LSZH 5x2x0,5 0233383 6,5 Drum/1000
MHS LSZH 10x2x0,5 0233386 8,5 Coil/100
MHS LSZH 10x2x0,5 0233385 8,5 Drum/1000
EQQXB Easy TM (halogen free EKKX)Pair-twisted communication cable with halogen free, flame
retardant insulation and sheath. An important feature of the cable
is that both insulation and sheath are easy to peel. You can even
peel the insulation with your nail.
Cable Nexans no. Outer diam. Length
EQQXB Easy TM 1 x 4 x 0,5 mm 17112041 3,5 mm Bobbin/100
EQQXB Easy TM 1 x 4 x 0,5 mm 17112071 3,5 mm Bobbin/500
EQQXB Easy TM 2 x 2 x 0,5 mm 17112241 4,3 mm Bobbin/100
EQQXB Easy TM 2 x 2 x 0,5 mm 17112271 4,3 mm Bobbin/500
EQQXB Easy TM 4 x 2 x 0,5 mm 17112441 5,5 mm Bobbin/100
EQQXB Easy TM 4 x 2 x 0,5 mm 17112471 5,5 mm Bobbin/500
EQQXB Easy TM 6 x 2 x 0,5 mm 17112641 6,0 mm Bobbin/100
EQQXB Easy TM 6 x 2 x 0,5 mm 17112671 6,0 mm Bobbin/500
EQQXB Easy TM 10 x 2 x 0,5 mm 17112941 7,3 mm Bobbin/100
EQQXB Easy TM 10 x 2 x 0,5 mm 17112971 7,3 mm Bobbin/500
EQQXB Easy TM 20 x 2 x 0,5 mm 17113098 9,8 mm Bobbin/500
EQQXB Easy TM 30 x 2 x 0,5 mm 17113198 11,7 mm Bobbin/500
EQQXB Easy TM 50 x 2 x 0,5 mm 17113398 14,4 mm Bobbin/500
EQQXB Easy TM 100 x 2 x 0,5 mm 17113598 19,5 mm Bobbin/500
FQQXBFlexible signal and alarm cables for intruder alarms and access
control systems.
Cable Nexans no. Outer diam. Length
FQQXB 4 x 0,22 mm2 17527141 3,7 mm Bobbin/100
FQQXB 4 x 0,22 mm2 17527171 3,7 mm Bobbin/500
FQQXB 6 x 0,22 mm2 17527241 4,2 mm Bobbin/100
FQQXB 6 x 0,22 mm2 17527271 4,2 mm Bobbin/500
FQQXB 8 x 0,22 mm2 17527341 4,7 mm Bobbin/100
FQQXB 8 x 0,22 mm2 17527371 4,7 mm Bobbin/500
FQQXB 12 x 0,22 mm2 17527441 5,4 mm Bobbin/100
FQQXB 12 x 0,22 mm2 17527471 5,4 mm Bobbin/500
15
FLAQQBRCombined power supply and signal cables for intruder alarms
and entry systems. The twisted pair signal element is unshielded.
Cable Nexans no. Outer diam. Length
FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17037141 6,5 mm Bobbin/100
FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17037171 6,5 mm Bobbin/500
FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17037298 8,0 mm Drum/500
FLAQQBR 4 x 1,0 + 2 x 2 x 0,22 mm2 17037698 8,7 mm Drum/500
FLQQBRCombined power supply and signal cables for intruder alarms
and entry systems. The twisted pair signal element is unshielded.
Cable Nexans no. Outer diam. Length
FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm2 17030698 8,5 mm Drum/500
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17030141 6,5 mm Bobbin/100
FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17030171 6,5 mm Bobbin/500
FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17030271 7,5 mm Bobbin/500
FLAQQLYCombined power supply and signal cable for intruder alarms
and entry systems. The pairs for signalling have a common
screen of aluminium/polyesterfoil.
The cable has a protective PE sheath covering the inner sheat of
halogen free flame retardant plastic compound and is intended
for fixed installations both indoor and outdoor.
Cabel Nexans no. Outer diam. Length
FLAQQLY 2 x 1,0 + 2 x 2 x 0,22 mm2 17039298 9,0 mm Drum/500
16
NEXANS SWEDEN ABKABELGATAN 1514 81 GRIMSÅS0325-800 00www.nexans.se@nexanssweden
CAB
LES
FOR
ALAR
M-
AND
SAF
ETY
SYST
EMS
2018