Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG........

184
Thermocouple Cables RTD’s Cables Heat Resistance Cables Instruments Cables Control Cables Network Cables Special Cables Lead Wires Cable Product Guide Sleeves Mineral Insulated Cables

Transcript of Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG........

Page 1: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

Thermocouple Cables

RTD’s Cables

Heat Resistance Cables

Instruments Cables

Control Cables

Network Cables

Special Cables

Lead Wires

Cable Product Guide

Sleeves

Mineral Insulated Cables

Page 2: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 3: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

ATeflon Insulated

T101 - T118 Twisted Cable................................................................................................

T201 - T219 PTFE / PTFE................................................................................................

T401 - T418 PTFE / PTFE / SS Braiding..........................................................................

T501 - T517 PTFE / Polymide / Copper Screen/PTFE........................................................

T601 - T618 PTFE / Silicon...............................................................................................

T701 - T718 PTFE / VFG/VFG..........................................................................................

T801 - T818 PTFE / PTFE / Asbestos..............................................................................

T901 - T916 PTFE / Fiber Glass / SS Braiding..................................................................

T151 - T168 PTFE / Polymide / Copper Screen / Silicon......................................................

T251 - T268 PTFE / Polymide / Copper Screen / PTFE / Asbestos......................................

T351 - T368 PTFE / Polymide / Mica / VFG..........................................................................

T451 - T468 PTFE / Polymide / PTFE / Mica / FG / SS Braiding..........................................

Silicon Insulated

S101 - S116 Silicon / Silicon...............................................................................................

S201 - S216 Silicon / VFG / VFG........................................................................................

S301 - S316 Silicon / FG / Copper Braiding........................................................................

S401 - S416 Silicon / FG / Silicon / Copper Braiding..........................................................

S601 - S615 Silicon / Copper Screen / Silicon....................................................................

PVC Insulated

P201 - P215 PVC / PVC......................................................................................................

P301 - P315 PVC / Almylar / PVC.......................................................................................

P401 - P415 PVC / Almylar / PVC G.I.Armouring / PVC.....................................................

S501 - S515 PVC / PVC / SS Braiding................................................................................

PFA Insulated

PF101 - PF116 PFA / PFA.......................................................................................................

PF201 - PF216 PFA / SS Braiding...........................................................................................

PF301 - PF316 PFA / PFA / SS Braiding..................................................................................

Polymide Insulated

K101 - K116 Polymide / Polymide..............................................................................................

K201 - K216 Polymide / PTFE/Polymide...................................................................................

K301 - K316 Polymide Twisted Cable.....................................................................................

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

A13

A14

A15

A16

A17

A18

A19

A20

A21

A22

A23

A24

A25

A26

A27

Thermocouple Cables

ContentsCompany Introduction.................................................................................................................. 1

Facility for Cable & Mineral Insulated Cables............................................................................ 2

1.1 Conductors..................................................................................................... 3

1.2 Insulation Material......................................................................................... 5

1.3 Laying (Twisting)............................................................................................ 8

1.4 Shielding/Braiding......................................................................................... 8

1.5 Sheathing....................................................................................................... 10

1.6 Tapes, Binders and Fillers............................................................................ 11

1.7 Printing........................................................................................................... 11

1.8 Spooling.......................................................................................................... 11

Page 4: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

BRTD Cables

Fiber Glass Insulated

F101 - F118 VFG / VFG......................................................................................................

F201 - F217 Polymide / VFG / VFG........................................................................................

F301 - F315 VFG/VFG / SS Braiding..................................................................................

F401 - F416 Polymide / VFG / FG / SS Braiding....................................................................

F601 - F616 Polymide / VFG / FG / Asbestos Braiding..........................................................

F801 - F816 Polymide / FG / Almylar / VFG / SS Braiding.....................................................

FEP Insulated

TF101 - TF116 FEP / FEP.......................................................................................................

TF201 - TF216 FEP / FEP / SS Braiding.................................................................................

TF301 - TF316 FEP / Almylar / FEP........................................................................................

TF401 - TF416 FEP / Polymide / Copper Screen / FEP / SS Braiding.......................................

TF601 - TF616 FEP / Polymide / Copper Screen / FEP.............................................................

TF901 - TF916 FEP / Silicon...................................................................................................

Alumina Fiber Insulated

A101 - A116 Alumina Fiber / Alumina Fiber.........................................................................

Ceramic Fiber Insulated

C101 - C116 Ceramic Fiber / Ceramic Fiber........................................................................

A28

A29

A30

A31

A32

A33

A34

A35

A36

A37

A38

A39

A40

A41

PTFE Insulated

RT101 - RT118 PTFE / PTFE..................................................................................................

RT201 - RT219 PTFE / PTFE / SS Braiding............................................................................

RT301 - RT318 PTFE / PTFE / Copper Screen / PTFE..........................................................

RT401 - RT413 PTFE / FEP.....................................................................................................

RT501 - RT517 PTFE / Silicon.................................................................................................

RT601 - RT617 PTFE / Almylar / PTFE...................................................................................

RT701 - RT717 PTFE / Almylar / PTFE/SS Braiding...............................................................

RT801 - RT817 PTFE / Polymide / PTFE Insulated....................................................................

RT901 - RT917 PTFE / PTFE / FG / SS Braiding....................................................................

RT151 - RT167 PTFE / Polymide / Copper Screen / FEP...........................................................

RT251 - RT267 PTFE / Polymide / Copper Screen / PTFE........................................................

RT351 - RT367 PTFE / PTFE / SS Braiding / PTFE...............................................................

PVC Insulated

RP101 - RP117 PVC / PVC......................................................................................................

RP201 - RP217 PVC / PP / Copper Screen / PVC...................................................................

RP301 - RP317 PVC / Almylar / PVC.......................................................................................

RP401 - RP417 PVC / Overall Almylar / PVC / GI Armouring / PVC........................................

FEP Insulated

RTF101 - RTF117 FEP / FEP.......................................................................................................

RTF201 - RTF217 FEP / FEP / SS Braiding.................................................................................

RTF301 - RTF317 FEP / Almylar / FEP........................................................................................

RTF401 - RTF417 FEP / Almylar/FEP / SS Braiding....................................................................

RTF501 - RTF517 FEP / Polymide / Copper Screen / FEP..............................................................

RTF601 - RTF617 FEP / FG / SS Braiding...................................................................................

RTF701 - RTF717 FEP / Silicon...................................................................................................

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

B14

B15

B16

B17

B18

B19

B20

B21

B22

B23

Contents

Page 5: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

CInstrumentation Cables

Fibre Glass Insulated

RF101 - RF114 VFG / VFG / SS Braiding................................................................................

RF201 - RF214 Polymide / VFG / VFG.......................................................................................

B24

B25

FEP Insulated

ITF101 - ITF 116 FEP / FEP / SS Braiding.................................................................................

ITF201 - ITF 216 FEP / Almylar / FEP.........................................................................................

ITF301 - ITF316 FEP / Copper Screen / FEP............................................................................

PE Insulated

IPE101 - IPE115 PE / Almylar / PVC..........................................................................................

PVC Insulated

IP101 - IP115 PVC / PVC......................................................................................................

IP201 - IP215 PVC / Almylar Screen / PVC / G.I. / PVC.......................................................

PTFE Insulated

It101 - IT 117 PTFE / PTFE / BC Screen / VFG...................................................................

XLPE Insulated

IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC........................................................

C1

C2

C3

C4

C5

C6

C7

C8

DHeat Resistance (HR) Cables

Fiber Glass Insulated

HF101 - HF118 Polymide / VFG / FG / SS Braiding...................................................................

HF201 - HF218 Polymide / VFG / VFG.......................................................................................

HF301 - HF318 Polymide / VFG / FG / Asbestos........................................................................

HF401 - HF418 Polymide / VFG / Almylar / VFG........................................................................

Silicon Insulated

HS101 - HS118 Silicon / Silicon Insulated...............................................................................

HS201 - HS218 Silicon / FG / SS Braiding..............................................................................

PTFE Insulated

HT101 - HT118 PTFE / Polymide / PTFE/ Mica / FG / SS Braiding...........................................

HT201 - HT218 PTFE / VFG / VFG.........................................................................................

HT301 - HT318 PTFE / VFG / FG / SS Braiding.....................................................................

HT401 - HT418 PTFE / PTFE / SS Braiding...........................................................................

HT501 - HT518 PTFE / PTFE / FG / SS Braiding...................................................................

HT601 - HT618 PTFE / Mica / Ceramic Fiber / Outer Ceramic Fiber / SS Braiding................

D1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D11

D12

Contents

Page 6: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

EControl Cables

Fiber Glass Insulated

Cf101 - CF118 Polymide/ VFG / Almylar / VFG.........................................................................

Silicon Insulated

CS101 - CS118 Silicon / Silicon...............................................................................................

PTFE Insulated

CT101 - CT118 PTFE / PTFE.................................................................................................

CT201 - CF218 PTFE / Polymide / Bc Screen / PTFE...............................................................

PE Insulated

CPE101 - CPE118 PE / PP / Copper Screen / Outer PVC...........................................................

E1

E2

E3

E4

E5

FNetwork Cables

CAT5UTPPVCG Cat 5 PVC Insulted (Unshielded Twisted Pair)...............................................

CAT5STPPVCG Cat 5 PVC Insulated (Shielded Twisted Pair Cable)......................................

CAT5UTPTEFG Cat 5 PTFE Insulted (Unshielded Twisted Pair)............................................

CAT5STPTEFG Cat 5 PTFE Insulated (Shielded Twisted Pair Cable)....................................

CAT6UTPPVCG Cat 6 PVC Insulated (Unshielded Twisted Pair)............................................

CAT6STPPVCG Cat 6 PVC Insulated ( Shielded Twisted Pair)...............................................

CAT6UTPTEFG Cat 6 PTFE Insulated (Unshielded Twisted Pair)..........................................

CAT6STPTEFG Cat 6 PTFE Insulated ( Shielded Twisted Pair).............................................

PDPPEBC022P Profibus DP Cable.........................................................................................

PDPPEBC016P Profibus PA Cable..........................................................................................

F1

F1

F2

F2

F3

F3

F4

F4

F5

F5

GSpecial Cables

Composite VGA Cable....................................................................................

LTFBC02406T Load Cell Cable.............................................................................................

Composite Cable...........................................................................................

HTMINPC10RE High Temperature Cable................................................................................

FHSNA4004RE Flat Heating Cable.........................................................................................

MDPETPC224G Modbus Cable................................................................................................

VGATFSPC24B VGA Cable.....................................................................................................

RG11UPEBC0B RG-11/U Cable(Unarmoured)........................................................................

RG11APEBC0B RG-11/U Cable(Armoured)............................................................................

RG59UPEBC0B RG-59/U Cable(Unarmoured)........................................................................

RG59APEBC0B RG-59/U Cable(Armoured)............................................................................

LNCTF1604CS Lance Cable...................................................................................................

RS485TPC03G RS-485 Cable.................................................................................................

G1

G1

G2

G3

G3

G4

G4

G5

G5

G6

G6

G7

G8

Contents

Page 7: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

Contents

HLead Wires

LPK101 - LPK121 PEEK Insulated..................................................................................................

LT101 - LT130 PTFE Insulated..................................................................................................

LTF101 - LTF123 FEP Insulated....................................................................................................

LET101 - LET123 ETFE Insulation.................................................................................................

LPF101 - LPF123 PFA Insulated.....................................................................................................

LMF101 - LMF123 MFA Insulated....................................................................................................

LFT101 - LFT121 PTFE / Fiber Glass Insulated............................................................................

LAM101 - LAM120 Mica / Alumina Fiber..........................................................................................

LP101 - LP123 PVC Insulated...................................................................................................

LS101 - LS123 Silicon Insulated................................................................................................

LFS101 - LFS120 Silicon / VFG.....................................................................................................

LK101 - LK123 Polymide Insulated...............................................................................................

LF101 - LF121 Fiber Glass Insulated........................................................................................

Lead Wire Ordering Codes...............................................................................

H1

H2

H3

H4

H5

H6

H7

H8

H9

H10

H11

H12

H13

H14

ISleeves

SFEP101 - SFEP114 PTFE Insulated..................................................................................................

SPFA101 - SPFA114 FEP Insulated.....................................................................................................

STEF101 - STEF114 PFA Insulated.....................................................................................................

SPVC101 - SPVC111 PVC Insulated....................................................................................................

SSIL101 - SSIL111 Silicon Insulated.................................................................................................

SFIB101 - SFIB107 Fibre Glass Insulated.........................................................................................

I1

I2

I3

I4

I5

I6

JMineral Insulated Cables

KTechnical Referances

General Information.......................................................................................................................................... J1

Testing of MI Cable........................................................................................................................................... J3

MI Thermocouple Cable.................................................................................................................................... J4

Precious Thermocouple Cable.......................................................................................................................... J5

MI Compensating Cable.................................................................................................................................... J6

MI Heater Cable................................................................................................................................................ J6

MI RTD Cable................................................................................................................................................... J7

MI Power Cable................................................................................................................................................. J8

Page 8: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

1

Company Introduction

Wires – CablesMineral Insulated Metal Sheathed Cables for demanding ApplicationsTEMPSENS Instruments (I) Pvt. Ltd Ltd is a part of Pyrotech group founded in 1976 with headquarters based in India, with an

assembly plant in Germany and sales office in China. The products of the company includes Temperature sensors, cables,

heaters, temperature calibration equipments and Furnaces.

Today we have a strong Sales & Services network, operating at various important locations in India, and global network spread in

more than 14 countries. Tempsens is continuously expanding its global presence in order to achieve its vision of becoming one of

the leading thermal engineering solution provider.

Tempsens has evolved as a leading cable company, boasting an extensive range of cables, wires, special cables, and Mineral

Insulated metal sheathed cables. Most of the cables are made to order and orders are routed swiftly through its agile productions

shops.

The catalogue provides a data sheets of cables which are regular market requirements. The employees of internal and field sales

teams are happy to advise and assist customers in finding the best solution for their needs, or any new cable out of the catalogue is

also welcome.

Production Plant

Tempsens was producing cables at small level before 2009, Considering the growing demand of cables in the market, It planned to

expand the cable facility. In 2009, It started new plant spread in area of 50,000 sq. ft. for large scale production of cables. From time

to time new and modern machines were added to the facilities in to order to offer customer wide range of cables.

Today Tempsens plant is equipped with latest cable machining - Extrusion lines, Stranding machines, Lapping machines etc. It has

a separate Mineral Cable plant for production of various types of MI Cables.

State-of-the-Art laboratory equipped with high standard testing setups, calibration furnaces and measuring instruments. Each and

every cable from raw material to finished product passes through strict quality check ensuring the best quality products.

Research & Development

Tempsens is focusing its R&D expertise and investments on continuing to develop new wire and cable that meets the challenges

confronting its customers. Tempsens strive for Higher performing, more cost effective, more reliable, more sustainable solutions,

for today and the future.

Tempsens pursues manufacturing excellence through continuous, comprehensive and coordinated efforts in five critical areas:

safety, quality, service, productivity and working capital management.

The culture of continuous improvement centers on the commitment and contributions of energetic and dedicated employees, who

share responsibility for performance. Whether it is a new product, or a new application the sales and R&D engineers are ready to

meet Customer's requirement.

What We Offer

Tempsens manufacturers wide range of Thermocouple & RTD Cables, Copper cable, HR Cable, Instrumentation Cable XLPE,

Control Cable, Hook up Wire and Sleeves. These cables are made in variety of configurations and insulations – PTFE, PFA, Fiber

Glass, FEP, Silicon, PVC, Polymide, Ceramic Fiber, and Alumina Fiber Insulated. Most of the cables are custom built and made to

order.

Tempsens U# l Tempsens U# ll Pyrometer Plant MI Cable Plant Tempsens Germany Tempsens China

Page 9: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

2

Cable Machining

MI Cable Plant

Test & Calibration Equipment

Ÿ Horizontal Tape Wrapping Machines

Ÿ PTFE Tape Extruders

Ÿ FEP/PFA/ETFE Extrusion plants

Ÿ Silicon Cable Extruders

Ÿ PVC Cable Extruders

Ÿ “High speed twister/bunchers

Ÿ Fiber braiding Machines

Ÿ SS Braiding Machines

Ÿ Fiber Lapping Machines

Ÿ Rigid Type twisting Machines

Ÿ Sintering Ovens

Ÿ Varnish Ovens

Ÿ Marking Machines

Ÿ Armouring Machine

Ÿ Draw Benches

Ÿ Horizontal Drawing Machines

Ÿ Annealing Furnaces

Ÿ Ammonia Cracker

Ÿ MGO Sintering Furnaces

Ÿ Polishing Machines

Ÿ Straightening Machine

Ÿ HV Testing

Ÿ Calibration Baths & Furnaces

Ÿ Digital Weighing Scale

Ÿ Spark Tester (On Line)

Ÿ Plating Thickness Testing Machine

Ÿ Flamability Test Setup

Ÿ Tensile tester

Ÿ LCR Meter

Ÿ Aging Test Setup

Ÿ Surface Resistance Test Setup

Ÿ Cold Bend Test Setup

Ÿ Automatic Temperature Calibration Setup

Ÿ Stereo Microscope

Ÿ Oxygen & Temperature Index Test Setup

Ÿ Smoke Density Test Setup

Ÿ HCL Gas Emission Test Setup

Facilities for Cables & Mineral Insulated Cables

Page 10: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

3

1.1 ConductorsAdditives

Conductors are sized to meet a given Cross Section Area. Same Cross Section area of Conductor can be made by Solid wire or Stranded wire. CSA of any constructed conductor shall be calculated by given formula

CSA (Cross Section Area): -

D = Diameter of single strand / wire.

N = No. of Strands.

Example : - 7 Strands of 0.30 mm = 0.50 Sq. mm

Where

1.1.1 Conductor Material

General Description

The centre component of any cable, the conductor is the term of metallic wire or wires that carry the signal or power through the cable. For signal & Power transmission there are wide types of metal that can be used as a conductor, however copper (Cu) is most commonly used as conductor due to its availability, fair conductivity & relatively low cost.

To prevent corrosion and enhance terminating (soldering), bare copper is coated with a metal that is not susceptible to oxidation and corrosion. Plated Copper is also used for better performance; Plating on copper wire offers additional improvement in electrical, Thermal properties & Mechanical Properties of copper wire. Tinned Copper (TPC), Silver Plated Copper (SPC), and Nickel Plated Copper (NPC) are commonly used as Plated Copper. Pure Nickel wire is also used for giving the excellent signal transmission. Pure Nickel is especially characterized by very high resistance to oxidation and chemical corrosion. Wires of Pure Nickel are mainly used for the manufacture of connections for heating elements.

Heating element conductor, Copper Clad steel & Silver Plated Copper Clad steel is also used due to their various characteristics.

Typical Characteristics of Plated Copper

S.R. Property Bare copper NPC

1 Conductivity Good Low

2 Resistivity Good Best

3 Thermal Stability Good Best

4 Cost Low Moderate

5Withstanding

Temperature (Max.)550°C 800°C

6 Solderabilty Good Very Low

7 Mechanical Strength Good Best

8 Corrosion Resistance Good Best

8 ApplicationPower transmission &

Powerdistribution

SPC

Best

Low

Moderate

High

250°C

Best

Good

Good

HF Applications & Micro cables

High thermal & chemical

application

Better

Good

Low

Moderate

150°C

Better

Low

Better

For Signal & Instrumentation

Applications

TPC

1.1.2 Thermocouple Conductor

Beyond above two types of conductor there is also one more grade that is compensating grade,

Thermocouple Grade conductors are used to do the measurement directly, this is used where the best accuracy is needed. These wires are suitable to measure its maximum temperature range. Extension wires are suitable to a limited temperature range, these are available with class-2 accuracy.

Compensating wires we made from alloys which has similar electrical characteristics as thermocouple material up to a limited temperature range, They are available only in class 2. compensating conductors are cheaper than extension or thermocouple conductors.

x N2π X D

4

Page 11: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

4

1.1.3 Stranding of ConductorConductors can be solid or stranded. The simplest form of conductor is single wire or Solid conductor, however this offers a smaller diameter. Solid conductors are prone to breaking after just a few bending cycles. Solid wire is used where we need fixed installation of cable. To enhance the durability and flexibility of conductor with remaining the same cross section as solid we use stranding process of multiple wires, in which the multiple wires are stranded together to make a the same size resulting more flexibility. Stranded wire is used where bending or repeated bending are required. For many high frequency applications stranded wire is used because they have low power loss than solid wire. Flexibility of Multistranded wires is more than solid wires.

As per IEC 60228 & IS 8130 Classes of conductors are defined in which higher the class, the more strands in the conductor are used, resulting more flexibility.

Class 1 : Solid / Single wire or Round wire

Class 2 : Stranded Conductor, 7 Strand (higher Sqmm will be 19 Strands)

Class 5 : Fine Multi-stranded Conductor for flexible 'general purpose' Installation.

Class 6 : Extra Fine or Multi-stranded Conductor for improved flexibility

Example of Concentric Strand Constructions

7-Strand 19-Strand 37-Strand

Table No. 1

1+6 1+6+12 1+6+12+18

COMPENSATING

CABLE

EXTENSION

CABLE

CONDUCTORT/CCONDUCTOR

COMBINATIONTYPE

INTERNATIONAL

COLOUR CODE

TO IEC 5843:1989

CONDUCTORCOMBINATIONS

+LEG –LEG

AMERICAN TO

ANSI/MC96.1

JAPANESE TO

JIS C 1610-1981TOLERANCE CLASS AS PER IEC 584.3 CABLE

TEMPERATURE

RANGE °C

T

TX

COPPER

COPPER CONSTANTAN

CONSTANTAN

±0.5°C -25°C TO +100°C

±0.5°C or 0.4% of T -185°C TO +300°C

J

JX

IRON CONSTANTAN

IRON CONSTANTAN -25°C TO +200°C

±1.5°C or 0.4% of T +20°C TO +700°C

NICROSIL NISILN

NX NICROSIL NISIL -25°C TO +200°C

0°C TO +1100°C

RCA

RCB

COPPER 0°C TO +100°C

0°C TO +200°C

B BC COPPER COPPER

G ALLOY 200* ALLOY 226*GC ±4.5°C 0°C TO +100°C

D ALLOY 203* ALLOY 225*DC ±4.5°C 0°C TO +100°C

C ALLOY 405* ALLOY 426*CC ±4.4°C 0°C TO +100°C

K

KX

KCA

KCB

CHROMEL ALUMEL

IRON CONSTANTAN

COPPER CONSTANTAN

CHROMEL ALUMEL

-25°C TO +200°C

±2.5°C

±2.5°C

0°C TO +150°C

0°C TO +100°C

±1.5°C or 0.4% of T 0°C TO +1100°C

SCA

SCB

0°C TO +100°C

0°C TO +200°C

E

EX

CHROMEL CONSTANTAN

CHROMEL CONSTANTAN -25°C TO +200°C

0°C TO +800°C

0°C TO +100°C

COPPERCOPPER

NICKEL MO

COPPER LOW VALUE

NICKEL

COPPER

COPPERCOPPER

NICKEL MO

COPPER LOW VALUE

NICKEL

-

CLASS 1 CLASS 2

±2.5°C or 0.75% of T

±1.5°C

±1.0°C

±1.5°C ±2.5°C

±1.5°C or 0.4% of T

±1.5°C ±2.5°C

±1.5°C or 0.4% of T

±1.5°C ±2.5°C

±2.5°C

±5.0°C

±2.5°C

±5.0°C-

-

-

±2.5°C

±1.0°C or 0.75% of T

±2.5°C or 0.75% of T

±2.5°C or 0.75% of T

±2.5°C or 0.75% of T

-

-

-

-

R

S

-

-

Page 12: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

5

Other Factor

The proposed use of the cable is the key reason for selecting one type of conductor over another. While the applications are as varied as the custom design cable made to meet them, some example includes

ŸCrimp Termination use as few strands as possible and avoid rope-lay or bunched conductors.

ŸSoldered terminations use tin & Silver Plated Copper for best result and avoid Nickel Plated Copper.

ŸData/Signal use Tinned Plated Copper Conductor

ŸDynamic use as many strands as possible for best results.

ŸHigh Temperature use Silver Plated Copper (+200 °C) or Nickel Plated Copper (+260 °C) for best results.

1.2 Insulation MaterialInsulation refers to the layer of plastic, polymer or high temperature compound that is applied directly over the conductor. Tempsens provide variety of insulation along with wide temperature range from -260 °C to 1200 °C. Most of the insulation materials are also used for sheathing purpose. Insulation material are choose according to their electrical, Mechanical and high temperature characteristics.

Sheathing refers to the outer most layer of the plastic, polymer or high temperature compound that is applied to a cable. The outer sheath (or jacket as it is also commonly known) is there to provide mechanical protection for the insulated cores & other component inside the cable.

Tempsens basically categorized four types of insulating material

Thermoplastic Compound

1.2.1 PVC (Poly vinyl chloride)

Generally self extinguishing, it's used for insulation and sheath. It turns into soft over 90 °C,at low temperature (-40 °C) it turns brittle. It has good mechanical properties, water resistant, flame retardant, chemical & oil resistant & very good resistance to abrasion.

Elastomeric Compound. PVC material have various type of Grade i.e. HR PVC, FR PVC, FRLS PVC.

Temp. Range from-40°C to 85°C

Unilay

Direction of stranding

Unilay Concentric

Ÿ Same lay direction

Ÿ Same lay length

Ÿ Manufactured in one

Ÿ Nearly round construction

Unidirectional

Ÿ Same lay direction

Ÿ Different lay length for each working step

Ÿ Manufactured in two working steps

Ÿ More round than unilay concentric

Different lay length impact on the roundness of the strand

Longer lay length = hexagonal/shorter lay length = circular

Equilay Concentric

Ÿ Different lay directions

Ÿ Same lay length

Ÿ Manufactured in two working steps

Ÿ very round construction

Conventional Concentric

Ÿ Different lay direction

Ÿ Different lay length for each working step

Ÿ Manufactured in two working steps

Ÿ Very round construction

Direction of stranding

True Concentric

Page 13: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

6

Properties StandardPVC

(General Purpose PVC)

FR PVC(Flame Retardant

PVC)

FRLS PVC(Flame Retardant) & low smoke PVC

HR PVC(Heat Resistant

PVC)

Specific gravity ASTM-D-792 1.44 +/- 0.03 1.60 +/- 0.03 1.47 +/- 0.03 1.32 +/- 0.03

Hardness (Shore A) ASTM D2240 79 +/- 3 93 +/- 3 91 +/- 3 85 +/- 3

Tensile Strength (Min.) Mpa

IS 10810 14 Mpa 12.5 Mpa 17 Mpa 20 Mpa

Elongation % (min) IS 10810 280% 150% 180% 225%

Volume 80 Min. 120 Min. 140 Min. 180% 225%

Resistivity (ohm.cm) IS 10810 5 X 10 ^13 10 X 10 ^13 8 X 10 ^13 2.6 X 10 ^13

Thermal stabilityat 200°C (min)

IS 5831 80 Min. 120 Min. 140 Min. 100 Min.

1.2.2 PE (Polyethylene)

It is used for only insulation purpose. It provide a very good insulating & dielectric properties, having excellent insulation resistance (> 5000 Mohms/Km).Its operating temperature is from -10 °C to 70 °C and it is suitable for application where good resistance to water absorption and to abrasion is required.

1.2.3 Silicon Insulation

Silicon insulation has superior heat resistance, cold resistance, excellent resistance and flexibility. Mechanical strength is enhanced by glass braiding having excellent electrical properties suit for high voltage. Silicon rubber is excellent chemical resistance to acids, oil & liquid fuels. These are flame retardant not propagating flames when exposed to fire action.

When silicon insulated cable is attacked by fire, sheath and Insulation crystallize maintaining their electrical properties for enough time to allow safety measure operations.

Temp. Range from -10°C to 70°C

Temp. Range from -50°C to 200°C

Properties Unit Value

Hardness Shore A 65 - 70Density Gm/Cm3 1.18 - 1.50

Elongation at break % 350 - 500Tensile Strength Mpa 5.5 - 9.5Tear resistance N/mm 20 - 45

1.2.4 XLPE Insulation

Known as Cross linked Polyethylene Insulation, Generally used for insulation of medium & high voltage cables. Its operating temperature range is -50 °C to 105 °C. It is used only for as insulating purpose.

1.2.5 EPR Insulation

Generally used for insulation of low voltage cables and instrument cables. Its operating temperature range is from -40 °C to 90°C.

1.2.6 PEEK Insulation

Polyetheretherketone (PEEK) is considered one of the highest performance plastics today. Polyetheretherketone, PEEK, is a semi-crystalline high temperature thermoplastic insulation. PEEK wire has a durability and resistance to harsh environments that makes it extremely useful in the down hole and deep drilling context for the oil industry. PEEK wire is also used in the energy production sector, including in the nuclear industry, due to its superior resistance to radiation. PEEK can be used continuously to 250°C and in hot water or steam without permanent loss in physical properties.

Features

ü Excellent Resistance to Radiation.

ü Superior high temperature performance

ü Improved compressive strength

ü Good electrical properties

ŸExcellent hydrolysis resistance

ŸExcellent chemical resistance

ŸVery low moisture absorption

Ÿ Inherently good wear and abrasion resistance

ŸUnaffected by continuous exposure to hot water or steam

Fluoro- Polymers Compound

1.2.7 PTFE Insulation

PTFE (Poly tetra fluoroethylene) insulation is used in a wide variety of high temperature applications as gas turbine and high voltage gas ignition wires. Due to its thin wall properties, PTFE is used in aerospace & defense and even in vaccum.It temperature range is from -267 to 260 °C.

Temp. Range from -50°C to 105°C

Temp. Range from-40°C to 90°C

Temp. Range up to 250°C

Temp. Range from-267°C to 260°C

Page 14: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

7

1.2.8 PFA Insulation

PFA (Per Fluoro Alkoxy) is used for many high temperature applications such as gas turbines. It has almost same properties like PTFE insulation. PFA has the excellent electrical and mechanical performance of PTFE with the added advantage of being easily and conventionally extruded. Its temperature range is from -260°C to 260°C.

Temp. Range from -260°C to 260°C

Temp. Range from -185°C to 150°C

Temp. Range from-200°C to 250°C

1.2.9 ETFE Insulation

ETFE (Ethylene Propylene Fluoro Ethylene) Insulation is a tough material with excellent tear strength, good tensile strength, outstanding mechanical properties. ETFE has a broad and useful temperature range and retains remarkable toughness at very low temperatures. Its used in extensively in both military and industrial applications. Its temperature range is from -185 to 150°C.

1.2.10 MFA Insulation

MFA insulation is also a Fluoro Polymer compound. Its temperature range is up to -200 °C to 250 °C. It is also have very good dielectric Constant & have excellent resistance to oil, UV rays, chemicals & moisture. It's widely used in high temperature applications, Military and Industrial applications.

Properties ASTM Standard PTFE FEP PFA ETFE

Applying Process Wrapped Extruded Extruded Extruded

Specific Gravity D792 2.15 2.15 2.15 1.76

Tensile Str.(Mpa) D1457 14 12.5 17 20

Elongation %(min) D1457 280 150 180 225

Hardness (HB) D2240 50-65 56 60 72

Melting Point 327 °C 327 °C 260 °C 306 °C 267 °C

Dielectric Strength/umm) D149 18 53 80 79

Volume Resistivity (ohm.cm) D257 >10^18 >10^18 >10^18 >10^18

Temperature Range JSS 51034 -267 to 260 -200 to 200 °C -260 to 260 °C -185 to 150 °C

High Temperature Insulation

1.2.11 Fiber Glass Insulation

is used for high temperature application its temperature range is from -73 °C to 600 °C. It has excellent abrasion resistance, excellent dielectric Properties, very good flame retardant and high temperature resistance characteristics. Due to these all characteristic this is widely used in Industrial application like Glass, Steel and Aluminum Plant. It is also used in heat treatment industries.

1.2.12 Ceramic Fiber Insulation

It has higher temperature range than Fiber glass. Its working temperature is up to 800 °C.It has excellent flame retardant & Heat Resistant properties. Widely used in industrial application like Glass, Steel, and Aluminum Plants. Also used in the heat treating industry, furnace surveys and temperature sensors.

1.2.13 Alumina Fiber

Alumina Fiber has highest temperature withstanding range up to 1200 °C. It has Excellent Flame retardant & Heat resists properties. Continuous filament Alumina Fiber adopted in conductors insulation and cables jacketing withstands very high temperatures maintaining significant strength and flexibility up to 1200 °C for long periods. They present also good chemical resistance.

Alumina Fiber Insulated Cables are useful in application where mineral insulated thermocouple cables are not suitable because of their low flexibility.

Temp. Range from -73°C to 600°C

Temp. Range from -72°C to 800°C

Temp. Range from -73°C to 1200°C

1.2.14 Polymide Insulation

Polymide tape are strong, amber colored, plastic films showing excellent physical, chemical & electrical properties at an extremely wide temperature range. These films don't melt and are fire resistant as they have the highest flammability rating. Its working temperature range is from -267 °C to 310°C.

Polymide film doe not soften at elevated temperatures, thus the film provides an excellent release surface at elevated temperatures.

Temp. Range from -267°C to 310°C

1. Colour White

2. Fiber form Continuous

3. Filament diameter 7 microns

4. Chemical composition Al O (72%) + SiO (28%)2 3 2

5. Crystal type A O12 3

6. Density 2.9 g/cm2

7. Tensile strength 200 Kgs/mm2

8. Tensile modulus 17,000 Kgs/mm2

9. Thermal resistance Up to 1,250°C as per the tensile strength retention percentage Vs increasing temperature curve show below :

Typical Physical Properties (Type F)

100

80

60

40

20

RT 8

00

1000

1200

1400

Temperature (After 24 hours heating) →

Tensi

le s

trength

rete

ntio

n(in %

)→

Page 15: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

8

Property 1 mil 2 mil 3 mil 5 mil Test method

Ultimate Tensile Strength at 73°F, Mpa 231 231 231 231 ASTM D-882-91, Method A*

Ultimate Tensile Strength at 392°F, Mp 139 139 139 139 ASTM D-882-91, Method A*

Ultimate Elongation at 73°F, % 72 82 82 82 ASTM D-882-91, Method A

Ultimate Elongation at 392°F, % 83 83 83 83 ASTM D-882-91, Method A

Density, g/cc 1.42 1.42 1.42 1.42 ASTM D-1505-90

Tensile Modulus at 73°F, GPa 2.5 2.5 2.5 2.5 ASTM D-882-91, Method A

Tensile Modulus at 392°F, Gpa 2 2 2 2 ASTM D-882-91, Method A

1.2.15 Mica

Mica tape is generally as intermediate tape for fire resistance purpose. It has excellent fire resistance, Flame retardant & Heat resistance properties.

1.2.16 Asbestos

The main reasons for the use of asbestos are its fire and heat resistance, electrical insulation properties, acid resistance, and durability. Electrical insulation is also used to protect the surfaces of conductors from such adverse conditions as moisture and chemicals, and to fill spaces where corona discharge is liable to occur.

1.3 Laying (Twisting)Cabling (also known as twisting or laying) is the process where all the cores are wrapped around one in an organized manner.

Many different types of components can be cabled together. For perfect round cable standard construction of laying are used, and where the number of cores are such that the laying is not perfectly round, filler material is introduced for the same.

Direction

Direction of the lay also plays an important role for providing the perfect laying of cable. Most cables are manufactured with alternating left-hand (S) and right-hand (Z) layers. This is done to make the cable evenly balanced, which can prevent it from twisting up in a single direction under dynamic use. Example for laying of 19 cores together as under

ü Centre : 1 X core laid straight (Center Core)

ü First Layer : 6 X Cores laid around the centre core with a right hand lay. (Z)

ü Second layer : 12 X Cores laid around the centre core with a left hand lay.(S)

Lay-Length

The lay length is the measured distance in mm or inches over which a core travels from its starting position in a layer. A cable with a short lay length will have a more flexible than a cable with a long lay length.

Lay length is often specified as a given number of twists per meter. This relates to the number of times a core should travel from its starting position, around the cable and back again over a given distance.

Flat Cables

Tempsens also makes parallel & flat cable construction up to 4 cores (depending on conductor cross section area). Flat cables provide a significant benefit with regards to bend radius if the cable is being fixed in a single direction. It also reduces time and cost. Flat cables are not ideal for applications which require freedom of movement in more than one direction.

1.4 Shielding / BraidingShielding or Braiding is applied for mechanical, magnetic and electrical protection.

Braided screen of Tinned copper, Sliver Plated Copper, Nickel Plated Copper & Bare Copper wires and Aluminum/Polyester foils provide protection from electrical and magnetic interference either from source within the cable ( such as power and data cores in the same cable) or from external sources. Braided screens offer a large amount of copper & coverage varies from approx 70 to 95% which is beneficial at lower frequencies whilst foil screen provide 100 % coverage are which is more effective at higher frequencies. A combination of both foil and braided provide best screening over a wide range of frequencies. Generally Tempsens provide minimum 80% coverage area in braiding form screen. Effectiveness of shielding is measured in dB, where higher the value of dB, better the screen.

For mechanical protection Stainless Steel wire braiding are offered at the outer most side of the cable sheath, where the cable must remain flexible. Metal Braiding also provides significant cut through resistance, along with excellent tensile strength.

Page 16: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

9

Tinned Copper Braid Screen

Bare Copper Braid Screen

Copper Tape Screen

Tinned copper wires braid 80% covering.

Applications:

It increases protection against electromagnetic interferences and it decreases electrical resistance.

Bare copper wires braid 80% covering.

Applications:

it increases protection against electromagnetic interferences and it decreases electrical resistence

Bare copper wires tape 100% covering.

Applications:

it increases protection against electromagnetic interferences and it decreases electrical resistence

Collective Screen Tinned copper drain wire under and in contact with AL/PETP (25µm/23µm) laminated tape applied metallic side down. PETP wrapping.

Applications:

Overall screen cables increases protection against electrostatic interferences.

Individual and Collective Screen Tinned copper drain wire under and in contact with AL/PETP (25µm/23µm) laminated tape applied metallic side down. PETP wrapping.

Applications:

Individual screen for multipair/multitriple cables. It increases protection against electrostatic interferences.

Shielding Category

Page 17: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

10

1.5 Sheathing Sheathing is also known as Jacket for the cable, it offers isolation from the earth-plane for any shielding of the cable, and it is primarily works as a mechanical protection for inner components of the cable from various a wide varieties of hazards. There are wide ranges of materials that can be used for sheathing cables. All materials have their own characteristics, advantages and limitations.

Generally most of the insulation materials work as sheathing compound except PE, XLPE Insulation. According to material characteristics we can choose the sheathing material.

Abrasion Resistance

Measure the rugged properties of a material, typically softer, more flexible sheath will exhibit a high degree of abrasion loss.

Corrosivity

Under fire condition, many materials such as FEP, although very good fire resistant, will release toxic and corrosive gases one they eventually ignite. Corrosive gases can damage sensitive equipments such as circuit boards, so consideration to this is essential.

Flammability

The degree to which the sheath will burn or spread the wire once ignited. Most material have improved Flame retardant (FR) additives i.e. FR PVC, FRLS PVC, LSZH PVC etc.

Flexibility

Flexibility is a degree to which a cable can bend or we can say flex life of cable is the frequency over which a cable can bent without breaking. Silicon materials have the best flexibility among all types of insulation.

Radiation

As with fuels and oils, continued exposure to radiation will break down plastic. Many different measurements scales exist.

Smoke

This refers to level of smoke that is generated by a material under fire conditions. Some material as LSZH PVC is especially for low smoke zero halogen.

Water Resistance

Where the sheath is concerned, this is the degree to which water can absorbed by the sheath.

-

-260 to 260°CPF PFA

TF FEP -200 to 200°C

APPEARANCE OF CABLE

-

ET -185 to 150°C

-60 to 260°CPEEKPoly Ether EtherKetone (Peek)

EXCELLENT EXCELLENTGOOD EXCELLENT EXCELLENT

-

XLPECross LinkedPoly Ethylene

-50 to 105°C GOOD GOODGOOD GOOD GOOD

PE Poly Ethylene -10 to 70°C GOOD GOODGOOD GOOD GOOD

EPR Ethylene Propylene

Rubber-40 to 90°C GOOD EXCELLENT EXCELLENT GOOD EXCELLENT

-267 to 310°C POOR

-73 to 600°CFiber Glass POOR POOR

-72 to 800°CCF/SF Ceramic Fiber/ Silica

POOR POORGOOD EXCELLENT POOR

-73 to 1200°CRF/NF/ALRefrasil/Nextel

Silica yarn/AluminaPOOR POORGOOD EXCELLENT POOR

Page 18: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

11

1.6 Tapes, Binders and FillersA binder tape is not a suitable insulating layer but it can be used as an isolation, For example if there are two ore more number of screened pair then to prevent from shorting among them we have to isolated them by binder tape. Some tape like mica glass tape is used as fire barrier tape.

Tempsens provide a wide range of binder tape in form of tapes & foil form.

Al/Polymide: : A Polyester-backed, polymide foil used for electrical screening at high temperature.

Al/Pr foil : A polyester-backed, aluminium foil used for electrical screening at low temperature range.

Cu/Pr foil : A polyester-backed, Copper foil used for electrical screening at low temperature range.

Polymide : foil used for high temperature and high radiation. Can be FEP Coated.

Mica : Tape used as a flame barrier in cable.

Sintered PTFE : foil used for high temperature use and also for pair or triad identification

Filler Material

The material used in multi-core cables to occupy large interstices formed by the assembled conductors, which imparts flexibility, strength and shape to the cable. Filler materials are generally fiber glass material or Non hygroscopic material that is used at the time of laying of cores for providing perfect roundness in the cable.

1.7 PrintingPrinting is done just before the cable is finally packed. For the correct identification of the cable, Tempsens cable products are continuously marked with relevant data: manufacturer (TEMPSENS), commercial name & cable name, no. of conductors, cross section, application standards, & other area of interest. Printing is generally done on PVC cables.

1.8 SpoolingThe completed cable is then wound onto a reel or spool. The spooling process requires very precise tension controls to ensure the cable won't tangle when being pulled out of its box. Spooling is done for PVC on wooden spool, and is provided with a suitable sticker marked with all the information such as Type of the Cable, its cross section, weight, and temp. etc. on it.

Generally Tempsens provide 500 Meter / 1000 Meter Spool length. Spool size and dimension are as per accordance with IS 10418: 1982 Standard.

Sr. NoCable Diameter

(mm)Spool Flange Diameter (mm)

For Length 500 Mtrs.Spool Flange Diameter (mm)

For Length > 1000 Mtrs.

1 1.00 DIN 160.00 DIN 200.00

2 2.00 DIN 250.00 DIN 310.00

3 3.00 DIN 310.00 DIN 350.00

4 4.00 DIN 350.00 DIN 445.00

5 5.00 DIN 350.00 DIN 445.00

6 6.00 DIN 445.00 560.00 Ply Spool

7 7.00 DIN 445.00 560.00 Ply Spool

8 8.00 460.00 Ply Spool 560.00 Ply Spool

9 9.00 510.00 Ply Spool DIN 600.00

10 10.00 560.00 Ply Spool DIN 600.00

DIN 160 DIN 200 DIN 310 DIN 445

DIN 600

Ply Spool (510 mm)

Ply Spool (560 mm)

Page 19: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

Thermocouple Cables A

Page 20: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 21: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A1

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistranded Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted

Operating Temp. : 260°C

Limits of Error : According to ASTM E230 / 77

Color Code : According to ANSI MC 96.1

CONSTRUCTION DETAILS AND DIMENSIONS

FEATURES

ü Max. Temp. upto 260ºC

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Metal braiding

ü Fibreglass braided

ü Polymide Insulated

ü Special Color Code

ü Calibration Test Repot

JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

ORDERING CODE

(TXXX)

101 to

118

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

01

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

T-101

PTFE TWISTED PAIR - 260ºC

THERMOCOUPLE CABLE

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

T101T102T103T104T105T106T107T108T109T110T111T112T113T114T115T116T117T118

7773717171

141

19

211

56

7

40

0.1220.152

0.20.2740.7110.1600.5100.2740.8100.3001.0200.3001.2900.3000.2000.3001.7880.300

0.080.120.220.421.2

0.140.2

0.450.50.5

0.811

1.31.3

1.251.52.54

0.360.450.570.811.390.480.510.820.810.9

1.021.261.291.521.421.55

1.7882.53

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

1.82.22.43.44.22.12.22.83.03.13.33.84.64.84.74.95.46.6

4.04.26.8

12.535.06.07.0

14.015.015.023.026.040.040.035.045.065.095.0

A

Page 22: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A2

THERMOCOUPLE CABLE

T-201

PTFE - PTFE INSULATED - 260°CSPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted / Flat

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Fiber braiding

ü Armoured

ü Twisted / Shielded Pair

ü Special Colour Code.

ü Calibration Test Repot

ü Available upto 1.1 KVJSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(TXXX)

201 to

219

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T201T202T203T204T205T206T207T208T209T210T211T212T213T214T215T216T217T218T219

17

1337

24142111

19777

141

40

1

35

0.510.7110.274

0.20.7110.30.2

0.3000.3

1.021.290.30

0.1520.1600.2000.2000.8100.2000.300

0.20.4

0.420.41.20.5

0.751

1.50.811.31.3

0.120.140.220.450.5

1.252.5

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.553.023.223.264.683.383.8

4.425

3.944.454.952.022.3

2.743.263.3

4.746.2

11.216.6

16.7816.840.42228365329

47.447.46.588.0211.216.622

44.675

A

Page 23: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A3

THERMOCOUPLE CABLE

T-401

PTFE - PTFE - STEEL BRAIDING INSULATED - 260°C

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted / Flat

Outer Jacket : PTFE Sheathed

Braiding : Stainless Steel Wire Braiding

Operating Temp. : 260°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Excellent Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Good Abrasion Resistance

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Repot

ü Available upto 1.1 KV

T401T402T403T404T405T406T407T408T409T410T411T412T413T414T415T416T417T418

7117

247

14321

21777

143

4019

1 0.510.2

0.7110.810.30.20.4

0.3000.2

1.2900.3

0.1520.1600.2740.2000.7110.2000.300

0.20.220.410.50.5

0.750.89

11

1.31.5

0.120.140.420.451.2

1.251.3

0.510.590.7110.810.891.1

1.211.261.271.291.550.460.480.810.841.391.421.52

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

3.13.43.73.94.14.95.15.15.25.25.8

2.422.523.8

3.885.35.4

5.58

1517273030405060607580

10.714.220

28.258.665

JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

75

ORDERING CODE

(TXXX)

401 to

418

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

A

Page 24: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A4

THERMOCOUPLE CABLE

T-501

PTFE - POLYMIDE - BC SCREENING - PTFE INSULATED - 260°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted

Isolator : Polymide Tape

Screening : Copper Screening

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Good Abrasion Resistance

ü Excellent Resist to Electro Magnetic Inter Ference

ü Silver Plated Copper Screening

ü NPC Screening

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Repot

ü Available upto 1.1 KV

JSS 51034, JSS 51038, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T501T502T503T504T505T506T507T508T509T510T511T512T513T514T515T516T517

7177

14214877

147

243

401

19

1 0.510.2

0.7110.274

0.30.300

0.30.2

0.1520.160.20.30.2

0.7110.2

0.1290.3

0.20.220.4

0.410.51

1.51.510.120.140.450.5

0.751.2

1.251.31.3

0.510.590.7110.810.891.261.551.560.460.480.840.891.1

1.391.421.291.52

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.63.63.84

4.45.15.75.72.6

2.653.84

4.65.35.45.1

5.54

1714.5202025436060

13.113.827.630

44.562.665.266.466.4

ORDERING CODE

(TXXX)

501to

517

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

A

Page 25: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A5

THERMOCOUPLE CABLE

T-601

PTFE - SILICON INSULATED - 200°CSPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted

Outer Jacket : Silicon Rubber Sheathed

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Superior Heat Resistance, Cold Resistance

ü Excellent Strength

ü Excellent Flexibility

ü Excellent Humidity Resistivity

ü Excellent Dielectrical Properties

ü Good Abrasion Resistance

ü Fiber Glass Braiding

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Repot

ü Available upto 1.1 KV

JSS 51034, ANSI MC 96.1, IS 9968

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

17

1337

24142111

19777

141

40

1 0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1600.2000.2000.8100.200

0.20.4

0.420.41.20.5

0.751

1.51.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.44.1

4.254.256.1

4.455.4

5.756.35.25.86.23.53.63.84.6

4.256

17.625.626.125.656.632

41.553.470

43.260.260.213

14.417.627.23258

T601T602T603T604T605T606T607T608T609T610T611T612T613T614T615T616T617T618

ORDERING CODE

(TXXX)

601to

618

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

A

Page 26: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A6

THERMOCOUPLE CABLE

T-701

PTFE - FIBER GLASS - FIBER GLASS INSULATED - 400°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE & Fiber Glass Insulation with high temperature Varnish

Construction : Twisted / Flat

Outer Jacket : Fiber Glass Insulation with High Temp. Varnish.

Operating Temp. : 400°C

Limit of Error : According to ASTM E230 / 77, IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Good Thermal Stability

ü Excellent Flame Retardant

ü Excellent Strength

ü Fair Abrasion Resistance

ü Good Dielectric Strength

ü Metal Braiding over Jacket

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T701T702T703T704T705T706T707T708T709T710T711T712T713T714T715T716T717T718

17

1337

24142111

19777

141

1

40

0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1600.2000.2000.8100.200

0.20.4

0.420.41.20.5

0.751

1.50.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

3.64

4.24.25.54.35

5.36.25

5.46.12.62.73.44.34.25.9

16.826

26.826

55.628395067

39.558.658.69.4

10.216.827.528

57.6

ORDERING CODE

(TXXX)

701to

718

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

A

Page 27: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A7

THERMOCOUPLE CABLE

T-801

PTFE - PTFE - ASBESTOS BRAIDING INSULATED - 400°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted / Flat

Inner Jacket : PTFE Insulation

Outer Jacket : Asbestos Braiding

Operating Temp. : 400°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Thermal Stability

ü Excellent Chemical Resistivity

ü Good Abrasion Resistance

ü Good Moisture Resistance.

ü Excellent Dielectric Strength

ü High Temperature Rated

ü Overall Metal Braiding

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T801T802T803T804T805T806T807T808T809T810T811T812T813T814T815T816T817T818

17

1337

24142111

19777

141

40

1 0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1600.2000.2000.8100.200

0.20.4

0.420.41.20.5

0.751

1.51.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

3.84.64.74.76.44.95.86.16.85.76.26.73.23.34.14.84.76.6

18.127.928.627.957.631

39.54767

42.862.562.517

17.918.5293060

ORDERING CODE

(TXXX)

801to

818

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

A

Page 28: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A8

THERMOCOUPLE CABLE

T-901

PTFE - FIBER GLASS - SS BRAIDING INSULATED - 400°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation.

Construction : Twisted / Flat

Inner Sheath : Fiber Glass Insulation with high Temp Varnish

Outer Sheath : Stainless Steel Wire Braiding

Operating Temp. : 400°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Good Thermal Stability

ü Excellent Flame Retardant

ü Excellent Mechanical Strength

ü Excellent Abrasion Resistance

ü High Temperature Rated

ü Overall Asbestos Braiding

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(TXXX)

901to

916

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T901T902T903T904T905T906T907T908T909T910T911T912T913T914T915T916

777

143

2177

141

2440191

35

1 0.510.2

0.2740.30.3

0.7110.3

0.1520.16

0.2000.8100.2000.2000.3001.2900.300

0.20.220.420.51

1.21.5

0.120.140.450.5

0.751.251.31.32.5

0.510.590.810.891.261.391.550.460.480.840.811.1

1.421.521.29

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

3.13.33.74.14.95.45.52.52.64

3.94.65.35.65.26.7

14.015.025.028.045.055.060.016.017.027.229.342.554.556.456.490.0

JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

A

Page 29: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A9

THERMOCOUPLE CABLE

T-151

PTFE - POLYMIDE - COPPER SCREENING - SILICON INSULATED - 200°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230/77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted

Isolator : Polymide Tape

Screening : Bare Copper / TPC/NPC/SPC

Outer Jacket : Silicon Insulation

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to IEC 5843

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°Cü Superior Heat Resistance, Cold

Resistanceü Excellent aging Resistanceü Excellent Flexibilityü Excellent Humidity Resistivityü Excellent Electrical Properties Suit

for High Voltageü Good Abrasion Resistanceü Excellent Resist to Electro

Magnetic Inter Ference

ü Metal Braiding over Jacket

ü Almyler Tape Shielding

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

ORDERING CODE

(TXXX)

151to

168

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T151T152T153T154T155T156T157T158T159T160T161T162T163T164T165T166T167T168

17

1337

24142111

19777

141

40

1 0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1600.2000.2000.8100.200

0.20.4

0.420.41.20.5

0.751

1.51.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.24.64.64.76.95.46

6.47.36

6.57.23.73.84.34.84.76.9

2543.544.643.58552

66.576

10071.595.495.4

21.6623.225.646.25288

IS 9968, JSS 51038, JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

A

Page 30: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A10

THERMOCOUPLE CABLE

T-251

PTFE - POLYMIDE - COPPER SCREENING - PTFE - ASBESTOS INSULATED - 300°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted

Isolator : Polymide Tape

Screening : Bare Copper / TPC / NPC / SPC

Outer Jacket : PTFE Insulation.

Overall Braiding : Asbestos Braiding

Operating Temp. : 300°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURESü Max. Temp. Up to 300°Cü Excellent Heat Resistantü Excellent Thermal Stabilityü Excellent High Voltage with

Standing Capabilityü Excellent Chemical Resistivityü Good Abrasion Resistanceü Excellent Resist to Electro

Magnetic Inter Ference

ü Metal Braiding over Jacket.

ü Twisted Pair

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(TXXX)

251to

268

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

JSS 51034, JSS 51038, ANSI MC 96.1

Voltage Grade : 300/500V

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T251T252T253T254T255T256T257T258T259T260T261T262T263T264T265T266T267T268

17

1337

24142111

19777

14

1

140

0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1601.2000.2000.81

0.200

0.20.4

0.420.41.20.5

0.751

1.50.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.75.35.55.57

5.76.56.87.56

6.97.33.83.94.85.65.57.3

24.236.237.136.27042

60.47693

63.483.583.5

20.6622.224.839.242

72.6

A

Page 31: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A11

THERMOCOUPLE CABLE

T-351

PTFE - PTFE - MICA - FIBER GLASS INSULATED - 500°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 / 77 & IEC5843

Insulation : PTFE Insulation

Construction : Twisted

Inner Sheath : PTFE Temperature Saturated

Outer Sheath : Mica Tape / Fiber Glass with High Temp. Varnish

Operating Temp. : 500°C

Limit of Error : According to ASTM E230 / 77, IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 500°C

ü Excellent Heat Resistant

ü Excellent Thermal Resistant

ü Excellent Flame Retardant

ü Good Abrasion Resistance

ü Excellent water submersion Properties

ü High Temperature Rated

ü Asbestos Braiding over Jacket

ü Metal braiding

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

JSS 51034, JSS 51037, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(TXXX)

351to

368

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T352T353T354T355T356T357T358T359T360T361T362T363T364T365T366T367T368

T35117

1337

24142111

19777

14

1

140

0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1600.2000.2000.8100.200

0.20.4

0.420.41.20.5

0.751

1.50.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.13.63.83.85.34.14.75

5.64.65.15.62.42.53.33.93.85.4

1421

25.221

49.629

35.83861

36.954.554.510.211.114.626.129

52.9

A

Page 32: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A12

THERMOCOUPLE CABLE

T-451

PTFE - POLYMIDE - PTFE - MICA - FG - SS BRAIDING INSULATED - 600°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : PTFE Temperature Saturated

Construction : Twisted

Isolator : Polymide Tape

Inner Sheath : PTFE Temperature Saturated

Outer Sheath : Mica Tape / Fiber Glass with High Temp. Varnish

Overall Braiding : Stainless Wire Armouring

Operating Temp. : 600°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 600°C

ü Excellent Heat Resistant

ü Good Thermal Stability

ü Excellent Flame Retardant

ü Excellent Strength

ü Excellent Mechanical Properties

ü Asbestos Braiding Over Jacket

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

JSS 51034, JSS 51037, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(TXXX)

451to

468

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

T451T452T453T454T455T456T457T458T459T460T461T462T463T464T465T466T467T468

17

1337

24142111

19777

14

1

140

0.5100.7110.2740.2000.7110.3000.2000.3000.3001.0201.2900.3000.1520.1601.2000.2000.81

0.200

0.20.4

0.420.41.20.5

0.751

1.50.811.31.3

0.120.140.220.450.5

1.25

0.510.7110.810.811.390.891.1

1.261.551.021.291.520.460.480.590.840.811.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.15.25.45.46.85.66.06.37.25.96.06.94.04.14.25.55.46.8

25.637.838.637.671.242

51.564.584

54.575.675.613.514.526.238.142

73.9

A

Page 33: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A13

THERMOCOUPLE CABLE

S-101

SILICON - SILICON INSULATED - 200°CSPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Silicon Insulation

Construction : Twisted

Outer Jacket : Silicon Insulated

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Excellent Resistance to Ozone & Corona Effect

ü Higher Flexibility

ü Easier Solder Termination

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

IS 9968, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

ORDERING CODE

(SXXX)

101to

116

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

S101S102S103

S104S105S106S107S108S109S110S111S112S113S114S115S116

7177

1417

24143

401

192135

7 0.1520.160.510.2

0.2740.2

0.810.300

0.20.3

0.7110.2

1.290.30.30.3

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.723.8

4.624.7

5.225.335.225.56.36.77

7.247.57.5

7.559

181932333738373955657580878882

127

A

Page 34: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A14

THERMOCOUPLE CABLE

S-201

SILICON - FIBER GLASS - FIBER GLASS INSULATED - 400°C

CONSTRUCTION DETAILS AND DIMENSIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Silicon / Fiber Glass Insulation with High Temp Varnish

Construction : Twisted / Flat

Outer Jacket : Fiber Glass Insulation with High Temp. Varnish

Operating Temp. : 400°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 400°C

ü Excellent Resistance to Ozone & Corona Effect

ü Excellent Heat Resistant

ü Higher Flexibility

ü Easier Solder Termination

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Color Code

ü Calibration Test Report

ü Available upto 1.1 KV

IS 9968, ANSI MC 96.1

Voltage Grade : 300/500V

ORDERING CODE

(SXXX)

201to

216

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

S201S202S203S204S205S206S207S208S209S210S211S212S213S214S215S216

7177

1417

24143

401

192135

7 0.1520.160.510.2

0.2740.2

0.810.300

0.20.3

0.7110.2

1.290.30.30.3

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

4.724.85.25.45.65.75.76

6.46.87

7.16.9

7.257.35

9

24252626333633344050576062626797

A

Page 35: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A15

THERMOCOUPLE CABLE

S-301

SILICON - FIBER GLASS - BARE COPPER BRAIDING - 300°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Silicon Insulation

Construction : Twisted / Flat

Outer Jacket : Fiber Glass Insulation with High Temp Varnish

Overall Braiding : Copper wire Braiding.

Operating Temp. : 300°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 300°C

ü Excellent Resistance to Ozone & Corona Effect

ü Excellent Heat Resistant

ü Higher Flexibility

ü Easier Solder Termination

ü Good Moisture, Chemical Abrasion Resistance

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV IS 9968, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(SXXX)

301to

316

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

S301S302S303S304S305S306S307S308S309S310S311S312S313S314S315S316

7177

1417

24143

401

192135

7 0.1520.160.510.2

0.2740.2

0.810.300

0.20.3

0.7110.2

1.290.30.30.3

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

4.624.75.15.35.55.65.65.96.36.76.97

6.87.157.258.9

252627273538353743536064666

75105

A

Page 36: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A16

THERMOCOUPLE CABLE

S-401

SILICON - FIBER GLASS - SILICON - COPPER BRAIDING - 200°C

IS 9968, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Silicon / Fiber Glass Insulation with High Temp. Varnish Insulated

Construction : Twisted

Inner Jacket : Silicon Insulated

Overall Braiding : Copper Wire Braiding

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Excellent Resistance to Ozone & Corona Effect

ü Excellent Heat Resistant

ü Higher Flexibility

ü Easier Solder Termination

ü Good Moisture, Chemical Abrasion Resistance

ü Almylar Tape Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

ORDERING CODE

(SXXX)

401to

416

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

S401S402S403S404S405S406S407S408S409S410S411S412S413S414S415S416

7177

1417

24143

401

192135

7 0.1520.160.510.2

0.2740.2

0.810.300

0.20.3

0.7110.2

1.290.30.30.3

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.25.46.16.67.27.37.27.47.88.18.38.48.39

9.11.5

30323538535253557080

100104108108110150

A

Page 37: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A17

THERMOCOUPLE CABLE

S-601

SILICON - COPPER SCREEN - SILICON INSULATION - 200°C

ORDERING CODE

(SXXX)

601to

615

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

CONSTRUCTION DETAILS AND DIMENSIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Silicon Insulation

Construction : Twisted

Screening : Copper Screening

Outer Jacket : Silicon Insulation

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Excellent Resistance to Ozone & Corona Effect

ü Excellent Heat Resistant

ü Higher Flexibility

ü Easier Solder Termination

ü Good Moisture, Chemical Abrasion Resistance

ü Almylar Tape Screening.

ü Screen with NPC, TPC, SPC

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

IS 9968, ANSI MC 96.1

Voltage Grade : 300/500V

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

S601S602S603S604S605S606S607S608S609S610S611S612S613S614S615

7177

1417

24143

401

1921

7 0.1520.160.510.2

0.2740.2

0.810.300

0.20.3

0.7110.2

1.290.30.3

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

55.25.55.66

6.26

6.47.37.78.58.28.38.58.6

262730314042484965707583909095

A

Page 38: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A18

THERMOCOUPLE CABLE

P-201

PVC - PVC INSULATED - 85°C

ORDERING CODE

(PXXX)

201to

215

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : PVC / FR PVC / FRLS PVC / HR PVC Insulation.

Construction : Twisted / Flat

Outer Jacket : PVC / FR PVC / FRLS PVC / HR PVC Sheathed.

Operating Temp. : 85°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Metal & Taped Shielding

ü Armouring

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

IS 694, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

7177

1417

24143

401

1921

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/F

3.73.85.25.65.75.65.86.26.97.37.67.47.87.910

22.5225.626.8

34.5637.64141

49.558

63.566

69.569.576110

P201P202P203P204P205P206P207P208P209P210P211P212P213P214P215 35

A

Page 39: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A19

THERMOCOUPLE CABLE

P-301

PVC - ALMYLAR - PVC INSULATED - 85°C

ORDERING CODE

(PXXX)

301to

315

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : PVC / FR PVC / FRLS PVC / HR PVC Insulation

Construction : Twisted

Shielding : Almylar Shield with ATC Drain Wire

Outer Jacket : PVC / FR PVC / FRLS PVC / HR PVC Sheathed

Operating Temp. : 85°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical

ü Armouring

ü Available with Zero Halogen Property

ü Available with Fire Retardant Property

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

IS 1554, ANSI MC 96.1

Voltage Grade : 300/500V

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

CONSTRUCTION DETAILS AND DIMENSIONS

P301P302P303P304P305P306P307P308P309P310P311P312P313P314P315

7177

1417

24143

401

192135

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.14.25.66

6.16

6.26.67.47.788

8.28.3

10.6

3032.13747

48.654546472

77.882.286.586.592

138

A

Page 40: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A20

THERMOCOUPLE CABLE

P-401

PVC - ALMYLAR - PVC - G.I. ARMOURING - PVC INSULATED - 85°C

ORDERING CODE

(PXXX)

401to

415

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : PVC / FR PVC / FRLS PVC / HR PVC Insulation

Construction : Twisted

Shielding : Almylar Shield with ATC Drain Wire

Inner Sheath : PVC / FR PVC / FRLS PVC / HR PVC Sheathed

Armouring : Galvanized Iron Wire, Round / Flat Strip

Outer Jacket : PVC / FR PVC / FRLS PVC / HR PVC Sheathed

Operating Temp. : 85°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Available with Zero Halogen Property

ü Available with Fire Retardant Property

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

IS 1554, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

P401P402P403P404P405P406P407P408P409P410P411P412P413P414P415

7177

1417

24143

401

192135

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

8.469.09.29.69.8

10.010.010.511.011.511.711.811.812.012.5

200215230240250262262278310318332335335348428

A

Page 41: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A21

THERMOCOUPLE CABLE

P-501

PVC - PVC - SS BRAIDING INSULATED - 85°C

ORDERING CODE

(PXXX)

501to

515

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : PVC / FR PVC / FRLS PVC / HR PVC Insulation

Construction : Twisted / Flat

Outer Sheath : PVC / FR PVC / FRLS PVC / HR PVC Sheathed

Overall Braiding : Stainless Steel Wire

Operating Temp. : 85°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Metal & Taped Shielding

ü G.I. Armouring

ü Available with Zero Halogen Property

ü Available with Fire Retardant Property

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV

CONSTRUCTION DETAILS AND DIMENSIONS

IS 694, ANSI MC 96.1

Voltage Grade : 300/500V

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

P501P502P503P504P505P506P507P508P509P510P511P512P513P514P515

7177

1417

24143

401

1921

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.30035

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/F

4.34.45.36.26.36.26.47.58

7.98.28.18.58.6

10.7

32.5237.640.8

50.5654.66060

69.682

87.591

97.597.5106145

A

Page 42: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A22

THERMOCOUPLE CABLE

PF-101

PFA - PFA INSULATED - 260°C

ORDERING CODE

(PFXXX)

101to

116

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded PFA Insulation

Construction : Twisted / Flat

Outer Jacket : Extruded PFA Insulated

Operating Temp. : 260°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü High Temperature Range

ü Excellent Fire Retardant Properties

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KVJSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

PF101PF102PF103PF104PF105PF106PF107PF108PF109PF110PF111PF112PF113PF114PF115PF116

77177

1417

24143

401

192135

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2.5 2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.022.3

2.552.753.223.263.3

3.383.8

4.424.684.744.454.95

56.2

6.588.0211.211.2

16.7816.622222836

40.444.647.447.45375

A

Page 43: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A23

THERMOCOUPLE CABLE

PF-201

PFA - SS BRAIDING INSULATED - 260°C

ORDERING CODE

(PFXXX)

201to

216

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded PFA Insulated

Construction : Twisted / Flat

Outer Braiding : Stainless Steel Wire Braiding

Operating Temp. : 260°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü High Temperature Range

ü Excellent Fire Retardant Property

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

77177

1417

24143

401

19

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.42.42.62.83.23.23.43.64

4.34.84.64.44.85.1

8911

13.51920222330384648505155

PF201PF202PF203PF204PF205PF206PF207PF208PF209PF210PF211PF212PF213PF214PF215 21

0.300 2.5 2 T / F 6.2 80PF216 35

A

Page 44: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A24

THERMOCOUPLE CABLE

PF-301

PFA - PFA - SS BRAIDING INSULATED - 260°C

ORDERING CODE

(PFXXX)

301to

316

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded PFA Insulation

Construction : Twisted / Flat

Outer Jacket : Extruded PFA Insulated

Outer Braiding : Stainless Steel Wire

Operating Temp. : 260°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü High Temperature Range

ü Excellent Fire Retardant Property

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Metal & Taped Shielding

ü Overall Asbestos Braiding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KVJSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

77177

1417

24143

401

19

PF301PF302PF303PF304PF305PF306PF307PF308PF309PF310PF311PF312PF313PF314PF315 21PF316 35

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.300 2.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2 T / F

2.82.93.23.33.83.93.84.24.64.95.55.35

5.65.7

12.11415162425252737465255636471

7 105

A

Page 45: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A25

THERMOCOUPLE CABLE

K-101

KAPTON - POLYMIDE INSULATED - 316°C

ORDERING CODE

(KXXX)

101to

116

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide Taped Insulation

Construction : Twisted / Flat

Outer Jacket : Polymide Tape Sheathed

Operating Temp. : 316°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 316°C

ü High Temperature with Standing

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Excellent Durability

ü Heat Resistant

ü Metal Coverings

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test ReportJSS 51037, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

K101K102K103K104K105K106K107K108K109K110K111K112K113K114

K115K116

77177

1417

24143

401

19

2135

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

1.81.92

2.12.62.72.63

3.43.84.34.44.24.64.75.8

67.58.69.8

12.51513

13.52029373538384267

A

Page 46: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A26

THERMOCOUPLE CABLE

K-201

POLYMIDE - PTFE - POLYMIDE INSULATED - 316°C

ORDERING CODE

(KXXX)

201to

216

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide Tape Insulation

Construction : Twisted / Flat

Inner Jacket : PTFE Insulation

Outer Jacket : Polymide Tape

Operating Temp. : 316°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 316°C

ü High Temperature with Standing

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Abrasion Resistance

ü Excellent Durability

ü Heat Resistant

ü Fire Resistant

ü Metal Covering

ü Taped or Metal Shielding.

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

JSS 51034, JSS 51037, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

K201K202K203K204K205K206K207K208K209K210K211K212K213K214K215K216

77177

1417

24143

401

192135

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/F

2.602.752.903.003.503.603.503.604.104.504.604.40 4.204.604.705.80

67.58.69.8

12.51513

13.52029373538384267

A

Page 47: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A27

THERMOCOUPLE CABLE

K-301

POLYMIDE INSULATED TWISTED CABLE - 316°C

ORDERING CODE

(KXXX)

301to

316

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

01

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide Taped Insulation

Construction : Twisted

Operating Temp. : 316°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 316°C

ü High Temperature with Standing

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Smaller Diameter

ü Excellent Durability

ü Heat Resistant

ü Metal Coverings

ü Metal & Taped Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

JSS 51037, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

K301K302K303K304K305K306K307K308K309K310K311K312K313K314K315K316

77177

1417

24143

401

192135

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

1.521.61.71.82.42.52.42.63

3.53.93.83.64

4.35.1

44.55.86.3

10.311.112

12.518.52228

28.528.5293353

A

Page 48: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A28

THERMOCOUPLE CABLE

F-101

FIBER GLASS - FIBER GLASS INSULATED - 550°C

ORDERING CODE

(FXXX)

101to

118

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS Conductor : Solid, Multistrand, Thermocouple Grade Materials

as per ASTM E230 & ANSI MC 96.1

Insulation : Braided or Lapped Fiber with Silicon Varnish, High Temp. Saturated

Construction : Twisted / Flat

Outer Sheath : Braided or Lapped Fiber with Silicon Varnish, High Temp. Saturated

Operating Temp. : 550°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 550°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü High Temperature Stability

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Double Fiber Braid Insulation

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test ReportIS 8784, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

F101F102F103F104F105F106F107F108F109F110F111F112F113F114F115F116F117F118

177131777

142414401921111

0.510.20.3

0.810.7111.2900.1520.16

0.2740.20.20.30.20.30.3

1.290.20.3

0.20.220.50.51.21.3

0.120.140.420.450.75

11.51.31.51.3

0.03140.07

0.510.590.890.811.391.290.460.480.810.841.1

1.261.421.521.551.290.20.3

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.22.43

2.94.64.42

2.13.223.34

4.44.744.945.054.51.21.6

111222204042

6.367.9515.817.724.533

42.54442444.76.8

A

Page 49: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A29

THERMOCOUPLE CABLE

F-201

POLYMIDE - FIBER GLASS - FIBER GLASS INSULATED - 550°C

ORDERING CODE

(FXXX)

201to

217

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide-Fiber glass Insulated, High Temp. Saturated

Construction : Twisted / Flat

Outer jacket : Fiber Glass with Silicon Varnish

Operating Temp. : 550°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 550°C

ü Excellent Electrical & Mechanical Properties

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü High Tensile Strength

ü Metal Over Braid

ü Twisted / Shielded Pair

ü Special Colour Code

ü Calibration Test Report

JSS 51037, IS 8784, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

F201F202F203F204F205F206F207F208F209F210F211F212F213F214F215F216F217

1771

241

144021777

1431

1935

0.510.20.3

0.810.2

1.0200.30.20.3

0.1520.16

0.2740.2

0.7111.290.30.3

0.20.220.50.5

0.750.81

11.251.5

0.120.140.420.451.21.31.32.5

0.510.590.890.811.1

1.021.261.421.550.460.480.810.841.391.291.52

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

3.23.44

3.84.64.45

5.66

2.252.3

3.453.5

4.884.685.26.1

1213222230303745587.89.1

19.5621

44.849.449.479

A

Page 50: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A30

THERMOCOUPLE CABLE

F-301

FIBER GLASS - FIBER GLASS - SS BRAIDING INSULATED - 600°C

ORDERING CODE

(FXXX)

301to

315

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Braided or Lapped Fiber with Silicon Varnish, High Temp. Saturated

Construction : Twisted / Flat

Outer Sheath : Braided or Lapped Fiber with Silicon Varnish, High Temp. Saturated

Overall Braiding : Stainless Steel Wire Braided

Operating Temp. : 600°C

Limit of Error : According to ASTM E230/77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 600°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü High Temperature Stability

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Double Fiber Braid Insulation

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test ReportIS 8784, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

F301F302F303F304F305F306F307F308F309F310F311F312F313F314F315

1771

241431

21777

141919

0.510.20.3

0.810.2

0.3000.7111.290.3

0.1520.16

0.2740.20.30.2

0.20.220.50.5

0.751

1.21.31.5

0.120.140.420.451.30.6

0.510.590.890.811.1

1.261.391.291.550.460.480.810.841.520.98

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.72.93.52.44.44.95.65

5.52.42.5

3.723.8

5.554.2

15.616

28.1283548

52.65764

10.613.3228.5629.161.437.8

A

Page 51: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A31

THERMOCOUPLE CABLE

F-401

POLYMIDE - FIBER GLASS - FIBER GLASS - SS BRAIDING INSULATED - 600°C

ORDERING CODE

(FXXX)

401to

416

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide Tapping with Braided or Lapped Fiber with High Temp. Varnish High Temp. Saturated

Construction : Twisted / Flat

Outer Sheath : Braided or Lapped Fiber with High Temp. Varnish High Temp. Saturated

Overall Braiding : Stainless Steel Wire

Operating Temp. : 600°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 600°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü High Temperature Stability

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Double Fiber Braid Insulation

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

JSS 51037, IS 8784, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

F401F402F403F404F405F406F407F408F409F410F411F412F413F414F415F416

1771

241

144021777

143

0.5100.2000.3000.8100.2001.0200.3000.2000.3000.1520.1600.2740.2000.7111.29010.30019

0.20.220.50.5

0.750.81

11.251.5

0.120.140.420.451.21.3

0.510.590.890.811.1

1.021.261.421.550.460.480.810.841.391.29

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

3.33.54.54.34.94.85.35.86

2.93

4.34.45.75.5

18.218.831.531.542

46.252.559.569

12.613.328.9

29.5657.963.5

1.3 1.52 T / F 5.9 63.5

A

Page 52: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A32

THERMOCOUPLE CABLE

F-601

POLYMIDE - FIBER GLASS - FIBER GLASS - ASBESTOS BRAIDING INSULATED - 600°C

ORDERING CODE

(FXXX)

601to

616

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide Tapping with Braided or Lapped Fiber with High Temp. Varnish High Temp. Saturated

Construction : Twisted / Flat

Outer Sheath : Braided or Lapped Fiber with High Temp. Varnish High Temp. Saturated

Overall Braiding : Asbestos Yarn

Operating Temp. : 600°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 600°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü High Temperature Stability

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Double Fiber Braid Insulation

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

JSS 51037, IS 8784, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

F601F602F603F604F605F606F607F608F609F610F611F612F613F614F615F616

1771

241

144021777

1431

19

0.5100.2000.3000.8100.2001.0200.3000.2000.3000.1520.1600.2740.2000.7111.2900.300

0.20.220.50.5

0.750.81

11.251.5

0.120.140.420.451.21.31.3

0.510.590.890.811.1

1.021.261.421.550.460.480.810.841.391.291.52

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

4.85

5.65.46.26

6.67.27.83.53.65.45.56.96.87.7

2021.233334346536274

14.516.932.534.365

68.568.5

A

Page 53: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A33

THERMOCOUPLE CABLE

F-801

POLYMIDE - FIBER GLASS - AL - MYLAR SCREEN - FIBER GLASS-SS BRAIDING INSULATED - 600°C

ORDERING CODE

(FXXX)

801to

816

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

JSS 51037, IS 8784, ANSI MC 96.1

Voltage Grade : 300/500V

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Polymide Tapping with Braided or Lapped Fiber with High Temp. Varnish High Temp. Saturated

Construction : Twisted

Screening : Al-Mylar Tape Screen with Drain wire

Outer Sheath : Braided or Lapped Fiber with High Temp. Varnish High Temp. Saturated

Overall Braiding : Stainless Steel Wire

Operating Temp. : 600°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 600°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü High Temperature Stability

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Double Fiber Braid Insulation

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

F801F802F803F804F805F806F807F808F809F810F811F812F813F814F815F816

1771

241

144021777

1431

19

0.5100.2000.3000.8100.2001.0200.3000.2000.3000.1520.1600.2740.2000.7111.2900.300

0.20.220.50.5

0.750.81

11.251.5

0.120.140.420.451.21.31.3

0.510.590.890.811.1

1.021.261.421.550.460.480.810.841.391.291.52

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.94

4.84.75.45.46

6.36.63.63.74.74.86.26.16.5

27.628.341.541.551.558.264.373.581

23.524.937.638.971.676.576.5

A

Page 54: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A34

THERMOCOUPLE CABLE

TF-101

FEP - FEP INSULATED - 200°C

ORDERING CODE

(TFXXX)

101to

116

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded FEP Insulated

Construction : Twisted / Flat

Outer Jacket : Extruded FEP Insulated

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Good Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Double Fiber Braid Insulation

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KVJSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

TF101TF102TF103TF104TF105TF106TF107TF108TF109TF110TF111TF112TF113TF114TF115TF116

77177

1417

24143

401

192135

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.022.3

2.552.753.223.263.3

3.383.8

4.424.684.744.454.95

56.2

6.588.0211.211.2

16.7816.622222836

40.4 44.647.447.45375

A

Page 55: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A35

THERMOCOUPLE CABLE

TF-201

FEP - FEP SS BRAIDING INSULATED - 200°C

ORDERING CODE

(TFXXX)

201to

216

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Table 1

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded FEP Insulated

Construction : Twisted / Flat

Outer Jacket : Extruded FEP Insulated

Outer Braiding : Stainless Steel Wire

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Higher Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Metal & Taped Shielding

ü Overall Asbestos Braiding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available upto 1.1 KV JSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX) (gm/meter)

TF201TF202TF203TF204TF205TF206TF207TF208TF209TF210TF211TF212TF213TF214TF215TF216

77177

1417

24143

401

192135

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

T / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / FT / F

2.422.523.13.43.8

3.883.94.14.95.15.35.45.2

5.585.86.8

10.714.2131520

28.221263645

58.660.262.262.265

100

A

Page 56: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A36

THERMOCOUPLE WIRE

TF-301

FEP - ALMYLAR - FEP INSULATED - 200°C

CONSTRUCTION DETAILS AND DIMENSIONS

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded FEP Insulated

Construction : Twisted

Outer Braiding : Almylar Screen with ATC Drain Wire

Outer Jacket : Extruded FEP Insulated

Operating Temp. : 200°C

Limit of Error : According to ASTM E230/77 / IEC 584

Color Code : According to ANSI MC 96.1

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Higher Resist to Electromagnetic Signal

ü Smaller Diameter

ü Good Mechanical Strength

ü Metal Covering

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available with 1.1KVJSS 51034, ANSI MC 96.1

Voltage Grade : 300/500V

ORDERING CODE

(TFXXX)

301to

316

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

TF301TF302TF303TF304TF305TF306TF307TF308TF309TF310TF311TF312TF313TF314TF315TF316

77177

1417

24143

401

192135

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.52.63.13.24

4.14

4.24.75

5.35.45.15.75.87

14.6616.219.720.428.529.8323239

46.554.257

58.958.965

105

A

Page 57: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A37

THERMOCOUPLE WIRE

TF-401

FEP - POLYMIDE - COPPER SCREEN - FEP - SS BRAIDING INSULATED - 200°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded FEP Insulated

Construction : Twisted

Isolator : Polymide Tape

Screening : Copper Screen

Outer Jacket : Extruded FEP Insulated

Overall Covering : Stainless Steel Wire.

Operating Temp. : 200°C

Limit of Error : According to ASTM E230/77 / IEC 584.

Color Code : According to ANSI MC 96.1

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Good Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Covering

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available with 1.1KV

JSS 51034, JSS 51038 ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(TFXXX)

401to

416

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

TF401TF402TF403TF404TF405TF406TF407TF408TF409TF410TF411TF412TF413TF414TF415TF416

77177

1417

24143

401

192135

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.52.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.13.23.43.54.74.84.74.95.45.86

6.16.26.36.47.6

19.3620.832.233.4

43.5645.948.248.260.275

83.589.596.596.599

126

A

Page 58: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A38

THERMOCOUPLE WIRE

TF-601

FEP - POLYMIDE - COPPER SCREEN - FEP INSULATED - 200°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded FEP Insulated

Construction : Twisted

Isolator : Polymide Tape

Screening : Copper Screen

Outer Jacket : Extruded FEP Insulated

Operating Temp. : 200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584

Color Code : According to ANSI MC 96.1

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Good Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Covering

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code.

ü Calibration Test Report

ü Available with 1.1KV

JSS 51034, JSS 51038 ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

ORDERING CODE

(TFXXX)

601to

616

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

TF601TF602TF603TF604TF605TF606TF607TF608TF609TF610TF611TF612TF613TF614TF615TF616

77177

1417

24143

401

19

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.300210.30035

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.5 2 Twisted

2.62.72.82.94.14.24.24.34.85.25.45.55.65.75.8

13.3614.824.224.9

33.5635.936.836.846.559

67.573.575.875.878

7 105

A

Page 59: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A39

THERMOCOUPLE WIRE

TF-901

FEP - SILICON INSULATED - 200°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Extruded FEP Insulated

Construction : Twisted

Outer Jacket : Extruded Silicon Rubber Insulation

Operating Temp. : 200°C

Limit of Error : According to ASTM E230/77 / IEC 584

Color Code : According to ANSI MC 96.1

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Good Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Abrasion Resistance

ü Metal Covering

ü Taped or Metal Shielding

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ü Available with 1.1KV

JSS 51034,IS 9968, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

ORDERING CODE

(TFXXX)

901to

916

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

TXC

Grade ofConductor

(XX)

0102-----

24

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

T-(Twisted)

Cable Formation

Table 1

TF901TF902TF903TF904TF905TF906TF907TF908TF909TF910TF911TF912TF913TF914TF915TF916

77177

1417

24143

401

19

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.83

3.63.84.24.34.24.45.45.86.46.46.26.67

14.215.519.620.526.628.13131

40.552

58.660.565657421

0.300 2.5 2 Twisted 8.5 10135

A

Page 60: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A

A40

THERMOCOUPLE WIRE

A-101

ALUMINA FIBER - ALUMINA FIBER INSULATED - 1200°C

ORDERING CODE

(AXXX)

101to

116

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

T

Grade ofConductor

(XX)

01

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

F-(Flat)

Cable Formation

Table 1

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Alumina Fiber Insulation

Construction : Flat

Outer Jacket : Alumina Fiber Insulation

Operating Temp. : 1200°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

FEATURES

ü Max. Temp. Up to 1200°C

ü High Temperature Range

ü Higher Accuracy Same as Thermocouple

ü Can Be Use as Thermocouple

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ASTM E230/77, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77177

1417

24143

401

19

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.300

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

FlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlat

2.8 X 1.62.9 X 1.73 X 1.8

3.2 X 1.93.6 X 2.13.7 X 2.13.6 X 2.13.8 X 2.24.2 X 2.44.5 X 2.64.9 X 2.84.9 X 2.84.7 X 2.75.0 X 2.95.3 X 2.9

891112

15.517192027313839414244

A101A102A103A104A105A106A107A108A109A110A111A112A113A114A115 21

0.300 2.5 2 Flat 6.1 X 3.4 71A116 35

Page 61: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A41

THERMOCOUPLE WIRE

C-101

CERAMIC FIBER - CERAMIC FIBER INSULATED - 800°C

ORDERING CODE

(CXXX)

101to

116

Conductor Size

(X)

KTJENRSDB

Type of T/C

(X)

T

Grade ofConductor

(XX)

01

No. of Pairs

(X)

A-(ANSI)I-(IEC)J-(JIS)

Color Code

(X)

F-(Flat)

Cable Formation

Table 1

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Thermocouple Grade Materials as per ASTM E230 & ANSI MC 96.1

Insulation : Ceramic Fiber Insulation

Construction : Flat

Outer Jacket : Ceramic Fiber Insulation

Operating Temp. : 800°C

Limit of Error : According to ASTM E230 / 77 / IEC 584.

Color Code : According to ANSI MC 96.1

FEATURES

ü Max. Temp. Up to 800°C

ü High Temperature Range

ü Higher Accuracy Same as Thermocouple

ü Can Be Use as Thermocouple.

ü Metal Coverings

ü Tighter Than Special Limit Accuracy Tolerance

ü Special Colour Code

ü Calibration Test Report

ASTM E230/77, ANSI MC 96.1

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

C101C102C103C104C105C106C107C108C109C110C111C112C113C114C115C116

77177

1417

24143

401

19

0.1520.1600.5100.2000.274 0.2000.8100.3000.2000.30007110.2001.2900.3000.300210.30035

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.31.31.5

0.460.480.510.590.810.840.810.891.1

1.261.391.421.291.521.55

2.5 2

FlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlat

2.9 X 1.73 X 1.8

3.1 X 1.93.3 X 2

3.7 X 2.23.8 X 2.23.7 X 2.23.9 X 2.34.3 X 2.54.6 X 2.75 X 2.9 5 X 2.9

4.8 X 2.85.1 X 35.4 X 3

9101213

16.5182021283340

40.5434447

6.2 X 3.5 74

A

Page 62: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

A

Page 63: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

RTD Cables B

Page 64: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 65: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B1

RTD CABLE

RT-101

PTFE - PTFE INSULATED - 260°C

ORDERING CODE

(RTXXX)

101to

118

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Metal Braiding Over Jacket

ü Twisted / Shielded Pair

ü Color Code as per Customer Requirement

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RT101RT102RT103RT104RT105RT106RT107RT108RT109RT110RT111RT112RT113RT114RT115RT116RT117RT118

77773717171

141

19

0.1220.1520.1930.2740.711 0.2000.1600.5100.2000.2740.8100.3001.0200.3000.200

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.31.3

1.25

0.360.450.570.811.390.480.510.820.810.9

1.021.261.291.521.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.42.52.73.24.62.72.93.43.43.63.8 4.54.74.94.5

9.510.113.822.159.112.213.726282843581151156040

0.300 1.5 1.55 Twisted 5 73211.788 2.5 1.788 Twisted 5.8 12010.300 4 2.53 Twisted 7.8 17056

Page 66: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B2

RTD CABLE

RT-201

PTFE - PTFE - SS BRAIDING INSULATED - 260°C

ORDERING CODE

(RTXXX)

201to

219

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Outer Jacket : PTFE Sheathed

Outer Braiding : Stainless Steel Wire Braiding

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties.

ü High Mechanical Strength

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Twisted / Shielded Pair

ü Color Code as per Customer Requirement

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

CONSTRUCTION DETAILS AND DIMENSIONS

DIN 43760, JSS 51034, IS 8130

Voltage Grade : 300/500V

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

19

0.1220.1520.1930.2740.711 0.2000.1600.5100.2000.2740.8100.3001.0200.3000.200

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.31.3

1.25

0.360.450.570.811.390.480.510.820.810.9

1.021.261.291.521.42

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.93.053.374.25.53.43.44.24.2

4.354.65.25.35.85.6

11.614.220.231.975

17.3817.532.233334860

78.178.175

RT201RT202RT203RT204RT205RT206RT207RT208RT209RT210RT211RT212RT213RT214RT215 40

0.300 1.5 1.55 Twisted 5.4 86RT216 211.788 2.5 1.788 Twisted 6.34 140RT217 10.300 4 2.53 Twisted 8.4 240RT218 560.102 0.05 0.32 Twisted 2.6 9RT219 7

Page 67: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B3

RTD CABLE

RT-301

PTFE - PTFE - COPPER SCREENING - PTFE INSULATED - 260°C

ORDERING CODE

(RTXXX)

301to

318

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : PTFE Insulation

Screening : Copper Screening

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Very good chemical Resistivity

ü Good Abrasion Resistance

ü Good Thermal Stability

ü Non-Flammability

ü Passes JSS 51034 Flame Test

ü Twisted / Shielded Triad

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034, JSS 51038, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RT301RT302RT303RT304RT305RT306RT307RT308RT309RT310RT311RT312RT313RT314RT315RT316RT317RT318

77773717171

141

19

0.1220.1520.1930.2740.711 0.2000.1600.5100.2000.2740.8100.3001.0200.3000.200

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.31.3

1.25

0.360.450.570.811.390.480.510.820.810.9

1.021.261.291.521.4240

0.300 1.5 1.55211.788 2.5 1.78810.300 4 2.5356

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

33.13.43.95.23.84

4.64.6

4.755

5.55.76.25.6

182027

36.67420273740405765858584

Twisted 6 94Twisted 6.96 150Twisted 8.76 215

Page 68: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B4

RTD CABLE

RT-401

PTFE - FEP INSULATED - 200°C

ORDERING CODE

(RTXXX)

401to

413

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

F-(Flat)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Flat

Outer Jacket : Extruded FEP Sheathed

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Outstanding Insulating Properties

ü Low Dielectric Constant

ü Very Good Chemical Resistivity

ü Good Abrasion Resistance

ü Non-Flammability

ü Passes JSS 51034 Flame Test

ü Shielding of Tape & Metal

ü Twisted Formation

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Metal CoveringDIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77

1973171

141

194021

0.1600.1930.27

0.2740.711 0.8100.3001.0200.3001.2900.3000.2000.300

0.140.220.240.421.20.50.5

0.751

1.31.3

1.251.5

0.480.6

0.62 0.821.390.810.9

1.021.261.291.521.421.55

FlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlatFlat

1.67X3.611.79X3.971.82X4.064.86X2.1

6.77X2.754.86X2.15.1X2.25

5.46X2.226.28X2.566.28X2.606.96X2.926.66 X 2.826.96X2.92

1519

20.528

60.52829505556

66.756567

RT401RT402RT403RT404RT405RT406RT407RT408RT409RT410RT411RT412RT413

Page 69: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B5

RTD CABLE

RT-501

PTFE - SILICON INSULATED - 200°C

ORDERING CODE

(RTXXX)

501to

517

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Outer Jacket : Extruded Silicon Sheathed

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Outstanding Insulating Properties

ü Low Dielectric Constant

ü Excellent Flexibility

ü Non-Flammability

ü Shielding of Tape & Metal

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Metal Covering DIN 43760, JSS 51034, IS 9968

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RT501RT502RT503RT504RT505RT506RT507RT508RT509RT510RT511RT512RT513RT514RT515RT516RT517

77773717171

141

19402135

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.2900.3000.2000.3000.300

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.31.3

1.251.52.5

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.13.43.74.36.83.54.14.44.44.95.46.46.4

10112030751820323738456680

1.521.421.55

2

TwistedTwistedTwistedTwisted

6.86.56.88.0

817690

140

Page 70: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B6

RTD CABLE

RT-601

PTFE - ALMYLAR SCREEN - PTFE INSULATED - 260°C

ORDERING CODE

(RTXXX)

601to

617

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Screening : Almylar Screening with 0.50 Sq. mm ATC Drain Wire

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Covering of Metal Braiding

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.62.83.14

5.63

3.14.24.14.34.55.15.2

16182426742027273637485876

RT601RT602RT603RT604RT605RT606RT607RT608RT609RT610RT611RT612RT613

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

5.65.45.77

777283

135

RT614RT615RT616RT617

Page 71: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B7

RTD CABLE

RT-701

PTFE - ALMYLAR - PTFE - SS BRAIDING - 260°C

ORDERING CODE

(RTXXX)

701to

717

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Screening : Almylar Screening with 0.50 Sq. mm ATC Drain Wire

Outer Jacket : PTFE Sheathed

Outer Braiding : Stainless Steel Wire

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RT701RT702RT703RT704RT705RT706RT707RT708RT709RT710RT711RT712RT713RT714RT715RT716RT717

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.13.33.64.66.23.53.64.84.74.95.15.75.8

20233033922432334343587090

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

6.26

6.47.8

9188

101159

Page 72: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B8

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RTD CABLE

RT-801

PTFE - POLYMIDE - PTFE 260°C

ORDERING CODE

(RTXXX)

801to

817

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : Polymide Tape

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Covering with Metal Braiding

ü Available with 1.1 KV Grade

ü Twisted & Shielded Triad

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034, JSS 51037

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.52.62.83.34.82.93

3.53.53.73.94.65

10.511.114.823.161.113.215283030

44.560117

RT801RT802RT803RT804RT805RT806RT807RT808RT809RT810RT811RT812RT813

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

5.14.75.26

1176276

124

RT814RT815RT816RT817

Page 73: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B9

RTD CABLE

RT-901

PTFE - PTFE - FG - SS BRAIDING 350°C

ORDERING CODE

(RTXXX)

901to

917

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : PTFE Insulation

Outer Jacket : Fiber Glass Insulation

Overall braiding : Stainless Steel Wire Braided

Operating Temp. : 350°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 350°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Twisted & Shielded Triad

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.43.53.74.25.83.83.94.44.44.64.95.65.9

15.518.223.83481

21.225.73941415976

141

RT901RT902RT903RT904RT905RT906RT907RT908RT909RT910RT911RT912RT913

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

6.15.76.27

1427797

150

RT914RT915RT916RT917

Page 74: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B10

RTD CABLE

RT-151

PTFE - POLYMIDE - COPPER SCREEN - FEP 200°C

ORDERING CODE

(RTXXX)

151to

167

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : Polymide Insulation

Screening : Copper Screening

Outer Jacket : Extruded FEP Insulation

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant

ü Low Dielectric Constant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Twisted & Shielded Triad

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS51034, JSS51037, JSS51038

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RT151RT152RT153RT154RT155RT156RT157RT158RT159RT160RT161RT162RT163RT164RT165RT166RT167

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.93

3.33.75

53.73.94.54.54.6

4.855.355.5

17192635711926

35.538.538.5556382

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

65.86.16.7

828190

146

Page 75: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B11

RTD CABLE

RT-251

PTFE - POLYMIDE - COPPER SCREEN - PTFE 260°C

ORDERING CODE

(RTXXX)

251to

267

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper , Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : Polymide Insulation

Screening : Copper Screening

Outer Jacket : PTFE Insulation

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Low Dielectric Constant

ü Outstanding Insulating Properties

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Twisted & Shielded Triad

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS51034, JSS51037, JSS51038

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RT251RT252RT253RT254RT255RT256RT257RT258RT259RT260RT261RT262RT263RT264RT265RT266RT267

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.93

3.33.75

53.73.94.54.54.6

4.855.355.5

17192635711926

35.538.538.5556382

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

65.86.16.7

8281 90

146

Page 76: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B12

RTD CABLE

RT-351

PTFE - PTFE - SS BRAIDING - PTFE INSULATED 260°C

ORDERING CODE

(RTXXX)

351to

367

Conductor Size

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper , Silver Plated Copper)

Core Insulation : PTFE Insulated

Construction : Twisted

Inner Sheath : PTFE Insulation

Outer Braiding : Stainless Steel Wire

Outer Sheath : PTFE Sheathed

Operating Temp. : 260°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Low Dielectric Constant

ü Outstanding Insulating Properties

ü Flame Retardant

ü High Mechanical Strength

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Twisted & Shielded Triad

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

0.1220.1520.1930.2740.711 0.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.43.553.94.76.23.93.94.74.74.95.66.26.2

15.618.22340892123374040607385

RT351RT352RT353RT354RT355RT356RT357RT358RT359RT360RT361RT362RT363

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

6.56.36.57.5

8590

105160

RT364RT365RT366RT367

Page 77: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B13

RTD CABLE

RP-101

PVC - PVC INSULATED - 85°C

ORDERING CODE

(RPXXX)

101to

117

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : PVC Insulation

Construction : Twisted

Outer Jacket : PVC Insulation

Operating Temp. : 85°C

Color Code : According to DIN

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Non-Flammability

ü Good Resistant to Abrasion

ü Excellent Flame Retardant

ü Good Heat Resistance

ü Good Flexibility

ü Shielding of Tape & Metal

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Metal Covering

ü Available with Fire Retard & Low Smoke Characteristic

ü Available with Zero Halogen Properties

DIN 43760, IS 694, BS5308, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RP101RP102RP103RP104RP105RP106RP107RP108RP109RP110RP111RP112RP113RP114RP115RP116RP117

777177

1417

2414401

0.2540.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.2001.290

0.350.120.140.2

0.220.420.450.50.5

0.751

1.251.3

0.760.450.480.510.590.810.510.810.891.1

1.261.421.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.84.74.84.95.45.94.95.96.57

7.27.67.3

33202228303840475063758588

1921353

0.3000.3000.3000.711

1.31.52.51.2

1.521.55

21.39

TwistedTwistedTwistedTwisted

7.98

9.57.6

8895

13790

Page 78: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B14

RTD CABLE

RP-201

PVC - COPPER SCREEN - PVC INSULATED - 85°C

ORDERING CODE

(RPXXX)

201to

217

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : PVC Insulation

Construction : Twisted

Isolator : Polyester Tape

Screening : Copper Wire

Outer Jacket : PVC Insulation

Operating Temp. : 85°C

Color Code : According to DIN

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Non-Flammability

ü Good Resistant to Abrasion

ü Excellent Flame Retardant

ü Good Heat Resistance

ü Good Flexibility

ü Shielding of Almylar Tape

ü Color code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Metal Covering

ü Available with Fire Retard & Low Smoke Characteristic

ü Available with Zero Halogen Properties

DIN 43760, IS 694, BS5308, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

777177

1417

2414401

0.2540.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.2001.290

0.350.120.140.2

0.220.420.450.50.5

0.751

1.251.3

0.760.450.480.510.590.810.510.810.891.1

1.261.421.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

6.55.45.95.55.66.55.56.57.27.68

8.38

402224324046485253565592

100

RP201RP202RP203RP204RP205RP206RP207RP208RP209RP210RP211RP212RP213

1921353

0.3000.3000.3000.711

1.31.52.51.2

1.521.55

21.39

TwistedTwistedTwistedTwisted

8.88.9

10.58.3

101 19416090

RP214RP215RP216RP217

Page 79: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B15

RTD CABLE

RP-301

PVC - ALMYLAR - PVC INSULATED - 85°C

ORDERING CODE

(RPXXX)

301to

317

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : PVC Insulation

Construction : Twisted

Screening : Almylar Tape Screen with Drain Wire

Outer Jacket : PVC Insulation

Operating Temp. : 85°C

Color Code : According to DIN

DIN 43760, IS 1554, BS 5308, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RP301RP302RP303RP304RP305RP306RP307RP308RP309RP310RP311RP312RP313RP314RP315RP316RP317

777177

1417

2414401

0.2540.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.2001.290

0.350.120.140.2

0.220.420.450.50.5

0.751

1.251.3

0.760.450.480.510.590.810.510.810.891.1

1.261.421.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

6.25.15.25.35.46.35.36.36.97.47.68

7.7

41262834364446535669839396

1921353

0.3000.3000.3000.711

1.31.52.51.2

1.521.55

21.39

TwistedTwistedTwistedTwisted

8.38.49.98

9610314598

FEATURES

ü Max. Temp. Up to 85°C

ü Non-Flammability

ü Good Resistant to Abrasion

ü Excellent Flame Retardant

ü Good Heat Resistance

ü Good Flexibility

ü Metal Screening

ü Color code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Metal Covering

ü Available with Fire Retard & Low Smoke Characteristic

ü Available with Zero Halogen Properties

AVAILABLE OPTIONS

Page 80: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B16

RTD CABLE

RP-401

PVC - ALMYLAR - PVC - G.I. ARMOURING - PVC INSULATION 85°C

ORDERING CODE

(RPXXX)

401to

417

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core insulation : PVC Insulation

Construction : Twisted

Screening : Almylar Tape Screen with Drain Wire

Inner Jacket : PVC Insulation

Armouring : G.I. Strip / Round Wire

Outer Jacket : PVC Insulation

Operating Temp. : 85°C

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 85°C

ü Non-Flammability

ü Good Resistant to Abrasion

ü Excellent Flame Retardant

ü Good Heat Resistance

ü Good Flexibility

ü Color code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Available with Fire Retard & Low Smoke Characteristic

ü Available with Zero Halogen Properties

DIN 43760, IS 1554, BS 5308, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

RP401RP402RP403RP404RP405RP406RP407RP408RP409RP410RP411RP412RP413RP414RP415RP416RP417

777177

1417

2414401

0.2540.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.2001.290

0.350.120.140.2

0.220.420.450.50.5

0.751

1.251.3

0.760.450.480.510.590.810.510.810.891.1

1.261.421.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

10.29.59.69.8

10.011.1011.2011.5011.5012.0

12.2012.4012.80

255200250220230240250265265300330340360

1921353

0.3000.3000.3000.711

1.31.52.51.2

1.521.55

21.39

TwistedTwistedTwistedTwisted

12.8013.014.512.5

360390490350

Page 81: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B17

RTD CABLE

RTF-101

FEP - FEP INSULATED - 200°C

ORDERING CODE

(RTFXXX)

101to

117

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulated

Construction : Twisted

Outer Jacket : Extruded FEP Sheathed

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Outstanding Insulating Properties.

ü Low Dielectric Constant

ü Very good chemical Resistivity

ü Good Abrasion Resistance

ü Non-Flammability

ü Passes JSS 51034 Flame Test

ü Shielding of Tape & Metal

ü Flat Cable Formation

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Metal CoveringDIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

0.1220.1520.1930.2740.7110.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.42.52.73.24.62.82.93.43.43.63.84.54.7

9.510.113.822.159.112.213.72628284358115

RTF101RTF102RTF103RTF104RTF105RTF106RTF107RTF108RTF109RTF110RTF111RTF112RTF113

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

4.94.55

5.8

1156073

120

RTF114RTF115RTF116RTF117

Page 82: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B18

RTD CABLE

RTF-201

FEP - FEP - SS BRAIDING INSULATED - 200°C

ORDERING CODE

(RTFXXX)

201to

217

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulation

Construction : Twisted

Outer Jacket : Extruded FEP Insulation

Outer Braiding : Stainless Steel Wire Braiding

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage use

ü Low Dielectric Constant

ü Excellent Fire Retardant property

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Twisted / Shielded Triad

ü Color Code as per Customer Requirement

ü Metal Covering

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.13.053.374.25.53.43.44.24.2

4.354.65.25.3

3514.217.831.975

17.3817.532.233334860

78.1

RTF201RTF202RTF203RTF204RTF205RTF206RTF207RTF208RTF209RTF210RTF211RTF212RTF213

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

5.85.65.4

6.34

78.17586

140

RTF214RTF215RTF216RTF217

Page 83: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B19

RTD CABLE

RTF-301

FEP - ALMYLAR SCREEN - FEP INSULATED - 200°C

ORDERING CODE

(RTFXXX)

301to

317

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulated

Construction : Twisted

Screening : Al-Mylar Screening with 0.50 Sq.mm ATC Drain Wire

Outer Jacket : Extruded FEP Sheathed

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

ü Available with Higher Voltage Grade

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

42.83.14

5.63

3.14.24.14.34.55.15.2

34182426742027273637485876

RTF301RTF302RTF303RTF304RTF305RTF306RTF307RTF308RTF309RTF310RTF311RTF312RTF313

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

5.65.45.77

777283

135

RTF314RTF315RTF316RTF317

Page 84: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B20

RTD CABLE

RTF-401

FEP - ALMYLAR - FEP - SS BRAIDING - 200°C

ORDERING CODE

(RTFXXX)

401to

417

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulated

Construction : Twisted

Screening : Almylar Screening with 0.50 Sq. mm ATC Drain Wire

Outer Jacket : Extruded FEP Insulated

Outer Braiding : Stainless Steel Wire

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Low Dielectric Constant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Covering of Metal Braiding

ü Available with 1.1 KV Grade

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.63.33.64.66.23.53.64.84.74.95.15.75.8

44233033922432334343587090

RTF401RTF402RTF403RTF404RTF405RTF406RTF407RTF408RTF409RTF410RTF411RTF412RTF413

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

6.26

6.47.8

9188

101159

RTF414RTF415RTF416RTF417

Page 85: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B21

RTD CABLE

RTF-501

FEP - POLYMIDE - COPPER SCREEN - FEP INSULATED - 200°C

ORDERING CODE

(RTFXXX)

501to

517

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulated

Construction : Twisted

Isolator : Polymide

Screening : Copper Screening

Outer Jacket : Extruded FEP Insulated

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Low Dielectric Constant

ü Outstanding Insulating Properties.

ü High Mechanical Strength

ü Good Thermal Stability

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Almylar Tape Screening

ü Covering of Metal Braiding

ü Available with 1.1 KV Grade

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS51034, JSS51037, JSS51038

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.33

3.33.75

53.73.94.54.54.6

4.855.355.5

32192635711926

35.538.538.5556382

RTF501RTF502RTF503RTF504RTF505RTF506RTF507RTF508RTF509RTF510RTF511RTF512RTF513

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

65.86.16.7

828190

146

RTF514RTF515RTF516RTF517

Page 86: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B22

RTD CABLE

RTF-601

FEP - FG - SS BRAIDING INSULATED - 300°C

ORDERING CODE

(RTFXXX)

601to

617

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulated

Construction : Twisted

Inner Sheath : Fiber Glass Insulation

Outer Braiding : Stainless Steel Wire

Operating Temp. : 300°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 300°C

ü Low Dielectric Constant

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Twisted & Shielded Pair

ü Available with 1.1 KV Grade

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.82.93.13.65.23.23.33.83.84

4.35

5.3

361924357119243942425366

125

RTF601RTF602RTF603RTF604RTF605RTF606RTF607RTF608RTF609RTF610RTF611RTF612RTF613

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

5.55.15.86.4

1266580

125

RTF614RTF615RTF616RTF617

Page 87: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B23

RTD CABLE

RTF-701

FEP - SILICON INSULATED - 200°C

ORDERING CODE

(RTFXXX)

701to

717

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Extruded FEP Insulation

Construction : Twisted

Outer Jacket : Extruded Silicon Insulation

Operating Temp. : 200°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage use

ü Low Dielectric Constant

ü Excellent Fire Retardant property.

ü Excellent Flexibility

ü Good Mechanical Strength

ü Good Moisture, Chemical Abrasion Resistance

ü Twisted / Shielded Triad

ü Color Code as per Customer Requirement

ü Metal Covering

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

DIN 43760, JSS 51034, IS 9968

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

43.13.44

6.53.23.84.14.14.5566

32112030751820323738456680

RTF701RTF702RTF703RTF704RTF705RTF706RTF707RTF708RTF709RTF710RTF711RTF712RTF713

19402135

0.3000.2000.3000.300

1.31.251.52.5

1.521.421.55

2

TwistedTwistedTwistedTwisted

6.56.26.57.7

817690

140

RTF714RTF715RTF716RTF717

Page 88: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B24

RTD CABLE

RF-101

FIBER GLASS - FIBER GLASS- SS BRAIDING INSULATED - 400°C

ORDERING CODE

(RFXXX)

101to

114

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Fiber Glass Insulation with High Temperature Varnish

Construction : Twisted

Inner Sheath : Fiber Glass Braiding

Overall Braiding : Stainless Steel Wire Braiding

Operating Temp. : 400°C

Color Code : According to DIN

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 400°C

ü Outstanding Insulating Properties

ü Low Dielectric Constant

ü Very Good Chemical Resistivity

ü Good Abrasion Resistance

ü Excellent Mechanical Strength

ü Shielding of Tape & Metal

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Asbestos CoveringDIN 43760, IS 8130

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77

1973171

141

194021

0.1600.1930.27

0.2740.7110.8100.3001.0200.3001.2900.3000.2000.300

0.140.220.240.421.20.50.5

0.751

1.31.3

1.251.5

0.480.6

0.620.821.390.810.9

1.021.261.291.521.421.55

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.103.503.604.005.604.004.304.705.205.305.905.806.00

18242835784242507087878295

RF101RF102RF103RF104RF105RF106RF107RF108RF109RF110RF111RF112RF113

35 0.300 2.50 2.00 Twisted 7.40 135RF114

Page 89: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

B25

RTD CABLE

RF-201

POLYMIDE - FIBER GLASS - FIBER GLASS INSULATED - 400°C

ORDERING CODE

(RFXXX)

201to

214

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0203--

36

No. of Core

(XXX)

RW0RRWCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RW0 (Red - White), RRW (Red - Red - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper)

Core Insulation : Fiber Glass Insulation with High Temperature Varnish

Construction : Twisted

Inner Sheath : Fiber Glass Braiding

Operating Temp. : 400°C

Color Code : According to DIN

FEATURES

ü Max. Temp. Up to 400°C

ü Outstanding Insulating Properties

ü Low Dielectric Constant

ü Very Good Chemical Resistivity

ü Good Abrasion Resistance

ü Shielding of Tape & Metal

ü Overall Metal Covering

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Asbestos CoveringDIN 43760, IS 8130,

Voltage Grade : 300/500V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77

1973171

141

194021

0.1600.1930.27

0.2740.7110.8100.3001.0200.3001.2900.3000.2000.300

0.140.220.240.421.20.50.5

0.751

1.31.3

1.251.5

0.480.6

0.620.821.390.810.9

1.021.261.291.521.421.55

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.703.203.303.905.503.904.204.605.305.405.905.806.20

12192431573535455266666272

RF201RF202RF203RF204RF205RF206RF207RF208RF209RF210RF211RF212RF213

35 0.300 2.50 2.00 Twisted 7.10 110RF214

Page 90: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

B

Page 91: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 92: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 93: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C1

INSTRUMENTATION CABLE

ITF-101

FEP - FEP - SS BRAIDING INSULATED - 200°C

ORDERING CODE

(ITFXXX)

101to

116

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, NPC, SPC, TPC As per IS 8130:84

Insulation : Extruded FEP Insulated

Construction : Twisted / Flat

Outer Jacket : Extruded FEP Insulated

Outer Braiding : Stainless Steel Wire

Operating Temp. : 200°C

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Higher Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Metal & Taped Shielding

ü Overall Asbestos Braiding

ü Special Colour Code

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77177

1417

24143

401

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.290

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.3

0.460.480.510.590.810.840.810.891.1

1.261.391.421.29

T/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/F

2.422.523.13.43.8

3.883.94.14.95.15.35.45.2

10.714.21517282930304050

58.66575

ITF101ITF102ITF103ITF104ITF105ITF106ITF107ITF108ITF109ITF110ITF111ITF112ITF113

192135

0.3000.3000.300

1.31.52.5

1.521.55

2

T/FT/FT/F

5.585.86.8

7580

100

ITF114ITF115ITF116

C

Page 94: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C2

INSTRUMENTATION CABLE

ITF-201

FEP - ALMYLAR - FEP INSULATED - 200°C

ORDERING CODE

(ITFXXX)

201to

216

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, NPC, SPC , TPC As per IS 8130:84

Insulation : Extruded FEP Insulated

Construction : Twisted

Outer Braiding : Almylar Screen with ATC Drain Wire

Outer Jacket : Extruded FEP Insulated

Operating Temp. : 200°C

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Higher Resist to Electromagnetic Signal

ü Smaller Diameter

ü Good Mechanical Strength

ü Metal Covering

ü Special Colour Code

ü Metal Shielding

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77177

1417

24143

401

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.290

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.3

0.460.480.510.590.810.840.810.891.1

1.261.391.421.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.52.63.13.24

4.14

4.24.75

5.35.45.1

14.6616.219.720.428.529.8323239

46.554.257

58.9

ITF201ITF202ITF203ITF204ITF205ITF206ITF207ITF208ITF209ITF210ITF211ITF212ITF213

192135

0.3000.3000.300

1.31.52.5

1.521.55

2

TwistedTwistedTwisted

5.75.87

58.965

105

ITF214ITF215ITF216

C

Page 95: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C3

INSTRUMENTATION CABLE

ITF-301

FEP - POLYMIDE - COPPER SCREEN - FEP INSULATED - 200°C

ORDERING CODE

(ITFXXX)

301to

316

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand,Electrolytic Grade Conductor Bare Copper, NPC, SPC, TPC As per IS 8130:84

Insulation : Extruded FEP Insulated

Construction : Twisted

Isolator : Polymide Tape

Screening : Copper Screen

Outer Jacket : Extruded FEP Insulated

Operating Temp. : 200°C

FEATURES

ü Max. Temp. Up to 200°C

ü Suitable for High Voltage Use

ü Low Dielectric Constant

ü Excellent Fire Retardant Property

ü Smaller Diameter

ü Good Mechanical Strength

ü Good Flexibility

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Covering

ü Special Colour Code

ü Asbestos Covering

JSS 51034, JSS 51037, JSS 51038, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77177

1417

24143

401

0.1520.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.290

0.120.140.2

0.220.420.450.50.5

0.751

1.21.251.3

0.460.480.510.590.810.840.810.891.1

1.261.391.421.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.62.72.82.94.14.24.24.34.85.25.45.55.6

13.3614.824.224.9

33.5635.936.836.846.559

67.573.575.8

ITF301ITF302ITF303ITF304ITF305ITF306ITF307ITF308ITF309ITF310ITF311ITF312ITF313

192135

0.3000.3000.300

1.31.52.5

1.521.55

2

TwistedTwistedTwisted

5.75.87

75.878

105

ITF314ITF315ITF316

C

Page 96: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C4

INSTRUMENTATION CABLE

IPE-101

PE - ALMYLAR - PVC INSULATED - 85 °C

ORDERING CODE

(IPEXXX)

101to

115

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, TPC As per IS 8130:84

Insulation : PE Insulation

Construction : Twisted

Shielding : Almylar Shield with ATC Drain Wire

Inner Sheath : PVC / FR PVC / FRLS PVC / HR PVC

Operating Temp : 85°C

FEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Armouring

ü Available with Zero Halogen Property

ü Available with Fire Retardant Property

ü Special Colour Code

IS 1554, BS 5308, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7177

1417

24143

401

19

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.3

0.480.510.590.810.840.810.891.1

1.261.391.421.291.52

Twisted TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.14.25.66

6.16

6.26.67.47.788

8.2

3032.13747

48.654546472

77.882.286.586.5

IPE101IPE102IPE103IPE104IPE105IPE106IPE107IPE108IPE109IPE110IPE111IPE112IPE113

2135

0.3000.300

1.52.5

1.552

TwistedTwisted

8.310.6

92138

IPE114IPE115

C

Page 97: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C5

INSTRUMENTATION CABLE

IP-101

PVC - PVC INSULATED - 85°C

ORDERING CODE

(IPXXX)

101to

115

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)F-(Flat)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, TPC As per IS 8130:84

Insulation : PVC / FR PVC / FRLS PVC / HR PVC

Construction : Twisted / Flat

Outer Jacket : PVC / FR PVC / FRLS PVC / HR PVC

Operating Temp. : 85°C

FEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical

ü Metal Coverings

ü Metal & Taped Shielding

ü Armouring

ü Special Colour Code

IS 694, BS 5308, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7177

1417

24143

401

19

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.3

0.480.510.590.810.840.810.891.1

1.261.391.421.291.52

T/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/FT/F

3.73.85.25.65.75.65.86.26.97.37.67.47.8

22.5225.626.8

34.5637.64141

49.558

63.566

69.569.5

IP101IP102IP103IP104IP105IP106IP107IP108IP109IP110IP111IP112IP113

2135

0.3000.300

1.52.5

1.552

T/FT/F

7.910

76110

IP114IP115

C

Page 98: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C6

INSTRUMENTATION CABLE

IP-201

PVC - ALMYLAR-PVC-G.I. ARMOURING - PVC INSULATED - 85°C

ORDERING CODE

(IPXXX)

201to

215

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, TPC, As per IS 8130:84

Insulation : PVC / FR PVC / FRLS PVC / HR PVC

Construction : Twisted

Shielding : Almylar Shield with ATC Drain Wire

Inner Sheath : PVC / FR PVC / FRLS PVC / HR PVC

Armouring : Galvanized Iron Wire, Round / Flat Strip

Outer Jacket : PVC / FR PVC / FRLS PVC / HR PVC

Operating Temp. : 85°C

FEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Available with Zero Halogen Property

ü Available with Fire Retardant Property

IS 1554, BS 5308, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7177

1417

24143

401

19

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.3

0.480.510.590.810.840.810.891.1

1.261.391.421.291.52

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

8.49.09.29.69.8

10.010.010.511.011.511.711.911.8

200215230240250262262278310318332335335

IP201IP202IP203IP204IP205IP206IP207IP208IP209IP210IP211IP212IP213

2135

0.3000.300

1.52.5

1.552

TwistedTwisted

12.012.5

348428

IP214IP215

C

Page 99: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C7

INSTRUMENTATION CABLE

IT-101

PTFE - PTFE-BC SCREENING - FIBER GLASS INSULATED - 300°C

ORDERING CODE

(ITXXX)

101to

117

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, NPC, SPC

Insulation : PTFE Insulation

Construction : Twisted

Isolator : PTFE Tape

Screening : Copper Screening

Outer Jacket : Fiber Glass Insulation with Varnish

Operating Temp. : 300°C

FEATURES

ü Max. Temp. Up to 300°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Abrasion Resistance

ü Silver Plated Copper Screening

ü NPC Screening

ü Twisted / Shielded Pair

ü Special Colour Code

JSS 51034, JSS 51038, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

17177

14214877

147

24

0.510.2

0.7110.274

0.30.300

0.30.2

0.1520.160.20.30.2

0.20.220.4

0.410.51

1.51.510.120.140.450.5

0.75

0.510.590.7110.810.891.261.551.560.460.480.840.891.1

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.43.63.84

4.45.15.75.72.6

2.653.84

4.6

1518242434507070

13.113.83134

44.5

IT101IT102IT103IT104IT105IT106IT107IT108IT109IT110IT111IT112IT113

340

0.7110.2

1.21.25

1.391.42

TwistedTwisted

5.35.4

62.665.2

IT114IT115

1 1.29 1.3 1.29 Twisted 5.1 66.4IT11619 0.3 1.3 1.52 Twisted 5.54 66.4IT117

C

Page 100: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

C8

INSTRUMENTATION CABLE

IX-101

XLPE - ALMYLAR - PVC-G.I. ARMOURING - PVC INSULATED - 85°C

ORDERING CODE

(IXXXX)

101to

115

Conductor Size

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

0102--

48

No. of Core

(XXX)

BW0CS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)BW0 (Blue - White), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Electrolytic Grade Conductor Bare Copper, TPC, As per IS 8130:84

Insulation : XLPE Insulation

Construction : Twisted

Shielding : Almylar Shield with ATC Drain Wire

Inner Sheath : PVC / FR PVC / FRLS PVC / HR PVC

Armouring : Galvanized Iron Wire, Round / Flat Strip

Outer Jacket : PVC / FR PVC / FRLS PVC / HR PVC

Operating Temp. : 85°C

FEATURES

ü Max. Temp. Up to 85°C

ü Excellent Physical Properties

ü Excellent Di-Electric Constant

ü Excellent Flame Retardant Property

ü Good Heat Resistivity

ü High Thermal Endurance

ü Good Moisture, Chemical Abrasion Resistance

ü Metal Coverings

ü Available with Zero Halogen Property

ü Available with Fire Retardant Property

IS 7098, IS 8130, BS 5308

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7177

1417

24143

401

19

0.1600.5100.2000.2740.2000.8100.3000.2000.3000.7110.2001.2900.300

0.140.2

0.220.420.450.50.5

0.751

1.21.251.31.3

0.480.510.590.810.840.810.891.1

1.261.391.421.291.52

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

8.4

9.09.29.69.8

10.010.010.511.011.511.711.911.8

180200210220230242242258280290308313313

IX101IX102IX103IX104IX105IX106IX107IX108IX109IX110IX111IX112IX113

2135

0.3000.300

1.52.5

1.552

TwistedTwisted

12.012.5

322390

IX114IX115

C

Page 101: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 102: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 103: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D1

HEAT RESISTANCE CABLE

HF-101

POLYMIDE - FIBER GLASS - FIBER GLASS - SS BRAIDING 400 °C

ORDERING CODE

(HFXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : Polymide Tape / Double Fiber Glass Insulation with High Temp Varnish

Construction : Twisted

Outer Sheath : Fiber Glass Insulation with High Temp. Varnish

Overall Braiding : Stainless Steel Wire

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Abrasion Resistance

ü Excellent Flame Retardant

ü Good Thermal Stability

ü Good Chemical Resistivity

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Asbestos BraidingJSS 51037, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.15.45.55.76.26.577

6.67.1

7.348.519.7

48546667768895

104106108117152166

HF101HF102HF103HF104HF105HF106HF107HF108HF109HF110HF111HF112HF113

84140

0.3000.300

610

3.114.1

TwistedTwisted

1113.5

251390

HF114HF115

128 0.400 16 5.11 Twisted 16.4 554HF116198 0.400 25 6.4 Twisted 18.8 835HF117278 0.400 35 7.6 Twisted 21.5 1200HF118

D

Page 104: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D2

HEAT RESISTANCE CABLE

HF-201

POLYMIDE - FIBER GLASS - FIBER GLASS BRAIDING 400°C

ORDERING CODE

(HFXXX)

201to

218

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : Polymide Tape / Double Fiber Glass Insulation with High Temp Varnish

Construction : Twisted

Outer Sheath : Fiber Glass Insulation with High Temp. Varnish

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Abrasion Resistance

ü Excellent Flame Retardant

ü Good Thermal Stability

ü Good Chemical Resistivity

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Asbestos Braiding

ü Metal CoveringJSS 51037, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.54.84.95.15.65.96.46.46

6.66.87.89

4044465362748082868897

125136

HF201HF202HF203HF204HF205HF206HF207HF208HF209HF210HF211HF212HF213

84140

0.3000.300

610

3.114.1

TwistedTwisted

10.212.3

210345

HF214HF215

128 0.400 16 5.11 Twisted 15.6 494HF216198 0.400 25 6.4 Twisted 17.8 755HF217278 0.400 35 7.6 Twisted 20 1100HF218

D

Page 105: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D3

HEAT RESISTANCE CABLE

HF-301

POLYMIDE - FIBER GLASS - FIBER GLASS - ASBESTOS BRAIDING 400°C

ORDERING CODE

(HFXXX)

301to

318

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : Polymide Tape / Double Fiber Glass Insulation with High Temp Varnish

Construction : Twisted

Outer Sheath : Fiber Glass Insulation with High Temp. Varnish

Overall Braiding : Asbestos Braiding

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Abrasion Resistance

ü Excellent Flame Retardant

ü Good Thermal Stability

ü Excellent Chemical Resistivity

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Metal CoveringJSS 51037, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.35.65.75.96.46.77.27.36.97.47.68.9

10.1

4652646571829099

101102108145156

HF301HF302HF303HF304HF305HF306HF307HF308HF309HF310HF311HF312HF313

84140

0.3000.300

610

3.114.1

TwistedTwisted

11.413.9

238370

HF314HF315

128 0.400 16 5.11 Twisted 16 525HF316198 0.400 25 6.4 Twisted 18.4 790HF317278 0.400 35 7.6 Twisted 21 1050HF318

D

Page 106: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D4

HEAT RESISTANCE CABLE

HF-401

POLYMIDE - FIBER GLASS - ALMYLAR - FIBER GLASS 400 °C

ORDERING CODE

(HFXXX)

401to

418

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : Polymide Tape / Double Fiber Glass Insulation with High Temp Varnish

Construction : Twisted

Screening : Almylar Screen With ATC Drain Wire

Outer Sheath : Fiber Glass Insulation with High Temp. Varnish

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Abrasion Resistance

ü Excellent Flame Retardant

ü Good Thermal Stability

ü Good Chemical Resistivity

ü Color Code as per Customer Requirement

ü Metal Shielding

ü Metal Covering

ü Asbestos BraidingJSS 51037, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.95.25.35.56

6.36.86.86.47

7.28.29.4

46505260698288889596

104135146

HF401HF402HF403HF404HF405HF406HF407HF408HF409HF410HF411HF412HF413

84140

0.3000.300

610

3.114.1

TwistedTwisted

10.612.7

220356

HF414HF415

128 0.400 16 5.11 Twisted 16 505HF416198 0.400 25 6.4 Twisted 18.2 768HF417278 0.400 35 7.6 Twisted 20.4 1111HF418

D

Page 107: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D5

HEAT RESISTANCE CABLE

HS-101

SILICON - SILICON INSULATED 200°C

ORDERING CODE

(HSXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : Silicon Insulation

Construction : Twisted

Outer Sheath : Silicon Insulation

Operating Temp. : 200°C

FEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant

ü Excellent Dielectric Property

ü Outstanding Insulating Properties

ü Excellent Flexibility

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Metal CoveringIS 9968, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.55.85.967

7.78

8.18.38.78.8

10.511.8

465052537292

100105107109117165185

HS101HS102HS103HS104HS105HS106HS107HS108HS109HS110HS111HS112HS113

84140

0.3000.300

610

3.114.1

TwistedTwisted

1315.3

333425

HS114HS115

128 0.400 16 5.11 Twisted 17.7 700HS116198 0.400 25 6.4 Twisted 23 1015HS117278 0.400 35 7.6 Twisted 27 1600HS118

D

Page 108: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D6

HEAT RESISTANCE CABLE

HS-201

SILICON - FIBER GLASS - SS BRAIDING INSULATED 200°C

ORDERING CODE

(HSXXX)

201to

218

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : Silicon Insulation

Construction : Twisted

Inner Sheath : Fiber Glass Insulation

Outer Sheath : Silicon Insulation

Operating Temp. : 200°C

FEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant

ü Good Flame Retardant property

ü Excellent Dielectric Property

ü Excellent Flexibility

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Metal CoveringIS 9968, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

55.45.55.76.36.57.67.57.68.18.210

11.2

28344445577081879092

107140200

HS201HS202HS203HS204HS205HS206HS207HS208HS209HS210HS211HS212HS213

84140

0.3000.300

610

3.114.1

TwistedTwisted

11.713.8

300420

HS214HS215

128 0.400 16 5.11 Twisted 16.9 635HS216198 0.400 25 6.4 Twisted 19.7 911HS217278 0.400 35 7.6 Twisted 22.1 1300HS218

D

Page 109: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D7

HEAT RESISTANCE CABLE

HT-101

PTFE - POLYMIDE - PTFE - MICA - FG - SS BRAIDING 600°C

ORDERING CODE

(HTXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : Polymide Tape

Inner Sheath : PTFE Insulation

Outer Sheath : Mica Tape / Fiber Glass Insulation

Overall Braiding : Stainless Steel Wire

Operating Temp. : 600°C

FEATURES

ü Max. Temp. Up to 600°C

ü Excellent Heat Resistant

ü High Temperature Resist

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.95.35.45.56

6.36.97

6.57.17.28

9.4

364561626880869599

105120160245

HT101HT102HT103HT104HT105HT106HT107HT108HT109HT110HT111HT112HT113

84140

0.3000.300

610

3.114.1

TwistedTwisted

10.713.5

325470

HT114HT115

128 0.400 16 5.11 Twisted 16.5 650HT116198 0.400 25 6.4 Twisted 19.7 925HT117278 0.400 35 7.6 Twisted 22.5 1350HT118

D

Page 110: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D8

HEAT RESISTANCE CABLE

HT-201

PTFE - FIBER GLASS - FIBER GLASS INSULATED 400°C

ORDERING CODE

(HTXXX)

201to

218

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : PTFE Insulation / Fiber Glass Insulation with High Temperature Varnish

Construction : Twisted

Outer Sheath : Fiber Glass Insulation with High Temperature Varnish

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü High Temperature Resist

ü Outstanding Insulating Properties.

ü Good Chemical Resistance

ü Good Abrasion Resistance

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Metal Covering

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.54.84.95.15.66

6.46.46.26.66.98.19.4

2530404153586675868688

147199

HT201HT202HT203HT204HT205HT206HT207HT208HT209HT210HT211HT212HT213

84140

0.3000.300

610

3.114.1

TwistedTwisted

10.413.5

250330

HT214HT215

128 0.400 16 5.11 Twisted 15.7 600HT216198 0.400 25 6.4 Twisted 19 860HT217278 0.400 35 7.6 Twisted 21.9 1165HT218

D

Page 111: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D9

HEAT RESISTANCE CABLE

HT-301

PTFE - FIBER GLASS - FIBER GLASS - SS BRAIDING 400°C

ORDERING CODE

(HTXXX)

301to

318

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : PTFE Insulation / Fiber Glass Insulation with High Temperature Varnish

Construction : Twisted

Outer Sheath : Fiber Glass Insulation with High Temperature Varnish

Overall Braiding : Stainless Steel Wire

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü High Temperature Resist

ü Outstanding Insulating Properties

ü Excellent Mechanical Properties

ü Good Chemical Resistance

ü Good Abrasion Resistance

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Asbestos Braiding for Better Chemical & Heat Resistance Purpose

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

HT301HT302HT303HT304HT305HT306HT307HT308HT309HT310HT311HT312HT313

84140

0.3000.300

610

HT314HT315

128 0.400 16HT316198 0.400 25HT317278 0.400 35HT318

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

55.35.55.66.46.677

6.87.27.58.6

10.1

3138485257748295

108110118175245

3.114.1

TwistedTwisted

11.114.2

300400

5.11 Twisted 16.5 9806.4 Twisted 19.8 9607.6 Twisted 22.7 1285

D

Page 112: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D10

HEAT RESISTANCE CABLE

HT-401

PTFE - PTFE - SS BRAIDING 260°C

ORDERING CODE

(HTXXX)

401to

418

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : PTFE Insulation

Construction : Twisted

Inner Sheath : PTFE Insulation

Overall Braiding : Stainless Steel Wire

Operating Temp. : 260°C

FEATURES

ü Max. Temp. Up to 260°C

ü Good Dielectric with Standing Property

ü Outstanding Insulating Properties

ü Excellent Mechanical Properties

ü Good Chemical Resistance

ü Good Abrasion Resistance

ü Passes JSS 51034 Flame Test

ü Color code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Asbestos Braiding for Better Chemical & Heat Resistance PurposeJSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

3.84.14.44.65.25.45.95.65.76.46.77.89.7

36324244557077788385

103147210

HT401HT402HT403HT404HT405HT406HT407HT408HT409HT410HT411HT412HT413

84140

0.3000.300

610

3.114.1

TwistedTwisted

1113.5

275410

HT414HT415

128 0.400 16 5.11 Twisted 16 700HT416198 0.400 25 6.4 Twisted 19.8 1010HT417278 0.400 35 7.6 Twisted 22.2 1300HT418

D

Page 113: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D11

HEAT RESISTANCE CABLE

HT-501

PTFE - PTFE - FIBER GLASS - SS BRAIDING 350°C

ORDERING CODE

(HTXXX)

501to

518

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : PTFE Insulation

Construction : Twisted

Inner Sheath : PTFE Insulation

Outer Sheath : Fiber Glass Insulation

Overall Braiding : Stainless Steel Wire

Operating Temp. : 350°C

FEATURES

ü Max. Temp. Up to 350°C

ü Good Dielectric with Standing Property

ü Outstanding Insulating Properties

ü Excellent Mechanical Properties

ü Good Chemical Resistance

ü Good Abrasion Resistance

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Asbestos Braiding for Better Chemical & Heat Resistance PurposeJSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.34.64.95.15.75.96.46.26.27

7.38.4

10.3

41384952637886889395115160225

HT501HT502HT503HT504HT505HT506HT507HT508HT509HT510HT511HT512HT513

84140

0.3000.300

610

3.114.1

TwistedTwisted

11.614.1

295435

HT514HT515

128 0.400 16 5.11 Twisted 16.6 740HT516198 0.400 25 6.4 Twisted 20 1045HT517278 0.400 35 7.6 Twisted 23 1340HT518

D

Page 114: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

D12

HEAT RESISTANCE CABLE

HT-601

PTFE - MICA - CERAMIC FIBER - OVERALL CERAMIC FIBER - SS BRAIDING 800°C

ORDERING CODE

(HTXXX)

601to

618

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

12

No. of Core

(XXX)

RB0RYBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).RB0 (Red - Black), RYB (Red - Yellow - Blue), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper & Tinned Plated Copper

Core Insulation : PTFE / Mica Tape / Ceramic Fiber

Construction : Twisted

Inner Sheath : Ceramic Fiber Insulation

Overall Braiding : Stainless Steel Wire

Operating Temp. : 800°C

FEATURES

ü Extreme High Temperature Up to 800°C

ü Excellent Heat Resistance

ü Excellent Mechanical Properties

ü Good Flame Retardant

ü Good Abrasion Resistance

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

6.26.36.46.67.27.6888

8.48.59.5

10.9

445363667589

105110115117115160225

HT601HT602HT603HT604HT605HT606HT607HT608HT609HT610HT611HT612HT613

84140

0.3000.300

610

3.114.1

TwistedTwisted

1214.2

295435

HT614HT615

128 0.400 16 5.11 Twisted 16.6 740HT616198 0.400 25 6.4 Twisted 20.8 1045HT617278 0.400 35 7.6 Twisted 23.8 1340HT618

D

Page 115: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 116: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 117: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

E1

CONTROL CABLE

CF-101

POLYMIDE - FIBER GLASS -ALMYLAR - FIBER GLASS 400°C

ORDERING CODE

(CFXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

BW0BWBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).BW0 (Blue - White), BWB (Blue - White - Brown), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper

Core Insulation : Polymide Tape / Double Fiber Glass Insulation with High Temp Varnish

Construction : Twisted

Screening : Almylar Screen With ATC Drain Wire

Outer Sheath : Fiber Glass Insulation with High Temp. Varnish

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Abrasion Resistance

ü Excellent Flame Retardant

ü Good Thermal Stability

ü Good Chemical Resistivity

ü Color Code as per Customer Requirement

ü Metal Shielding

ü Metal Covering

ü Asbestos Braiding

JSS 51037, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7

717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

4.95.25.35.56

6.36.86.86.47

7.28.29.4

46505260698288889596

104135146

CF101CF102CF103CF104CF105CF106CF107CF108CF109CF110CF111CF112CF113

84140

0.3000.300

610

3.114.1

TwistedTwisted

10.612.7

220356

CF114CF115

128 0.400 16 5.11 Twisted 16 505CF116198 0.400 25 6.4 Twisted 18.2 768CF117278 0.400 35 7.6 Twisted 20.4 1111CF118

E

Page 118: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

E2

CONTROL CABLE

CS-101

SILICON - SILICON INSULATED 200°C

ORDERING CODE

(CSXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

BW0BWBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).BW0 (Blue - White), BWB (Blue - White - Brown), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper

Core Insulation : Silicon Insulation

Construction : Twisted

Outer Sheath : Silicon Insulation

Operating Temp. : 200°C

FEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant

ü Excellent Dielectric Property

ü Outstanding Insulating Properties

ü Excellent Flexibility

ü Color Code as per Customer Requirement

ü Almylar Tape Shielded and Metal Shielding

ü Metal Covering

IS 9968, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7717

24143

401

19213556

0.2000.2540.8100.3000.2000.3000.7110.2001.2900.3000.3000.3000.300

0.220.350.50.5

0.751

1.21.251.31.31.52.54

0.590.760.810.891.1

1.261.391.421.291.521.55

22.56

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.55.85.967

7.78

8.18.38.78.8

10.511.8

405052537292

100105107109117165185

CS101CS102CS103CS104CS105CS106CS107CS108CS109CS110CS111CS112CS113

84140

0.3000.300

610

3.114.1

TwistedTwisted

1315.3

333425

CS114CS115

128 0.400 16 5.11 Twisted 17.7 700CS116198 0.400 25 6.4 Twisted 23 1015CS117278 0.400 35 7.6 Twisted 27 1600CS118

E

Page 119: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

E3

CONTROL CABLE

CT-101

PTFE - PTFE INSULATED - 260°C

ORDERING CODE

(CTXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

BW0BWBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).BW0 (Blue - White), BWB (Blue - White - Brown), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper

Core Insulation : PTFE Insulated

Construction : Twisted

Outer Jacket : PTFE Sheathed

Operating Temp. : 260°C

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Outstanding Insulating Properties

ü Good Thermal Stability

ü Good Mechanical Strength

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Metal Braiding Over Jacket

ü Twisted / Shielded Pair

ü Color Code as per Customer Requirement

ü Asbestos Braiding for Better Chemical & Heat Resistance PurposeJSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

77773717171

141

0.1220.1520.1930.2740.7110.1600.5100.2740.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.820.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.42.52.73.24.62.72.93.43.43.63.84.54.7

9.510.113.822.159.112.213.72628284358115

CT101CT102CT103CT104CT105CT106CT107CT108CT109CT110CT111CT112CT113

1940

0.3000.200

1.31.25

1.521.42

TwistedTwisted

4.94.5

11560

CT114CT115

21 0.300 1.5 1.55 Twisted 5 73CT1161 1.788 2.5 1.788 Twisted 5.8 120CT117

56 0.300 4 2.53 Twisted 7.8 170CT118

E

Page 120: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

E4

CONTROL CABLE

CT-201

PTFE - POLYMIDE - COPPER SCREEN - PTFE 200°C

ORDERING CODE

(CTXXX)

201to

218

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

BW0BWBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).BW0 (Blue - White), BWB (Blue - White - Brown), CS0 (Customer specification)

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper

Core Insulation : PTFE Insulated

Construction : Twisted

Isolator : Polymide Insulation

Screening : Copper Screening

Outer Jacket : PTFE Insulation

Operating Temp. : 260°C

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant

ü Low Dielectric Constant

ü Outstanding Insulating Properties

ü Flame Retardant

ü Passes JSS 51034 Flame Test

ü Color Code as per Customer Requirement

ü Available with 1.1 KV Grade

ü Twisted & Shielded Triad

ü Asbestos Braiding for Better Chemical & Heat Resistance PurposeJSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.1220.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.080.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.360.450.570.811.390.480.510.840.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

2.93

3.33.75

53.73.94.54.54.6

4.855.355.5

17192635711926

35.538.538.5556382

CT201CT202CT203CT204CT205CT206CT207CT208CT209CT210CT211CT212CT213

1940

0.3000.200

1.31.25

1.521.42

TwistedTwisted

65.8

8281

CT214CT215

21 0.300 1.5 1.55 Twisted 6.1 90CT21635 0.300 2.5 2.00 Twisted 6.7 146CT21756 0.300 4.00 2.53 Twisted 8.8 196CT218

E

Page 121: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

E5

CONTROL CABLE

CPE-101

PE - POLYSTER TAPE - COPPER SCREEN - PVC INSULATED - 85°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Bare Copper, Nickel Plated Copper, Silver Plated Copper, Tinned Plated Copper

Core Insulation : Extruded PE Insulated

Construction : Twisted

Isolator : Polyster Tape

Screening : Copper Screening

Outer Jacket : Extruded PVC Insulated

Operating Temp. : 85°C

FEATURES

ü Max. Temp. Up to 85°C

ü Outstanding Insulating Properties

ü High Mechanical Strength

ü Good Thermal Stability

ü Flame Retardant

ü Color Code as per Customer Requirement

ü Almylar Tape Screening

ü Covering of Metal Braiding

Is 1554, Is 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

ORDERING CODE

(CPEXXX)

101to

118

Conductor Size

(XXX)

BC0NPCTPCSPCPN0

Type of Conductor

(XX)

0102--

50

No. of Core

(XXX)

BW0BWBCS0

Color Code

(X)

T-(Twisted)

Cable Formation

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), PN0 (Pure Nickel).BW0 (Blue - White), BWB (Blue - White - Brown), CS0 (Customer specification)

CABLE SIZE

NO. OF STRANDS

STRANDDIAMETER

(mm)

AREA OF CONDUCTOR

2(mm)

BARE CONDUCTOR

DIA.(mm)

FORMATIONCABLE

DIMENSION (mm)(max.)

CABLE WT. (APPROX.) (gm/meter)

7777371

14171

141

0.2540.1520.1930.2740.7110.1600.5100.2000.8100.3001.0200.3001.290

0.350.120.220.421.2

0.140.2

0.450.50.5

0.751

1.3

0.760.450.570.811.390.480.510.840.810.9

1.021.261.29

TwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwistedTwisted

5.64.95.26

8.25

5.16.267

7.588

5522

33.564.5 12026

32.768.572.572.590

105135

CPE101CPE102CPE103CPE104CPE105CPE106CPE107CPE108CPE109CPE110CPE111CPE112CPE113

1940

0.3000.200

1.31.25

1.521.42

TwistedTwisted

8.58.4

135128

CPE114CPE115

21 0.300 1.5 1.55 Twisted 8.5 152CPE11635 0.300 2.5 2.00 Twisted 10.5 195CPE11756 0.300 4.0 2.53 Twisted 12.5 253CPE118

E

Page 122: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

E

Page 123: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 124: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 125: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

F

F1

CAT-5 UTP CABLE

CAT5UTPPVCG

UNSHIELDED TWISTED PAIR

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

CAT-5 STP CABLE

CAT5STPPVCG

SHIELDED TWISTED PAIR

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 24 AWG, Solid

Insulation : HDPE Insulation

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Grey / Blue

FEATURES

ü Storage Temp. Range : -20°C to 75°C

ü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 60°C

ü Capacitance : - 15 pF/ft

ü Nominal Velocity of Propagation : - 70%

ü Voltage Grade : 300 Volt

ü DC Resistance at 20°C : 99.38 Ohms / Km. (Max.)

ü Maximum DCR Unbalanced at 20°C(%) : 3

ORDERING CODE

CAT5 - UTP - PVC - (X) Outer Color

G - GreyB - Blue

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 24 AWG, Solid

Insulation Material : HDPE Insulation

Outer Shield Material : Aluminum Foil-Polyester Tape with 100 % Coverage Area

Drain Wire Material : Annealed Tinned Copper

Drain Wire Size : 7 X 0.30 mm (0.50 Sqmm)

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Grey / Blue

FEATURES

ü Storage Temp. Range : -20°C to 75°C

ü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 60°C

ü Capacitance : -15 pF/ft

ü Nominal Velocity of Propagation : -67%

ü Voltage Grade : 300 Volt

ü DC Resistance at 20°C : 99.38 Ohms / Km.(Max.)

ü Maximum DCR Unbalanced at 20°C (%) : 3

ORDERING CODE

CAT5 - STP - PVC - (X) Outer Color

G - GreyB - Blue

Page 126: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

F

F2

CAT-5 UTP CABLE

CAT5UTPTEFG

UNSHIELDED TWISTED PAIR (PTFE INSULATED)

CAT-5 STP CABLE

CAT5STPTEFG

SHIELDED TWISTED PAIR(PTFE INSULATED)

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 24 AWG, Solid

Insulation : PTFE Insulation

Outer Sheath : PTFE Sheathed

Outer Sheath Color : Grey / Blue

FEATURES

ü Operating Temp. Range : -267°C to 260°C

ü Capacitance : - 15 pF/ft

ü Nominal Velocity of Propagation : -70%

ü Voltage Grade : 300 Volt

ü High Temperature Resistance

ü Excellent Dielectric with Standing Properties

ü DC Resistance at 20°C : 99.38 Ohms / Km. (Max.)

ü Excellent Mechanical Strength

ORDERING CODE

CAT5 - UTP - TEF - (X) Outer Color

G - GreyB - Blue

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 24 AWG, Solid

Insulation Material : PTFE Insulation

Outer Shield Material : Polymide Backed Aluminum Foil-Polyester Tape with 100 % Coverage Area

Drain Wire Material : Annealed Tinned Copper

Drain Wire Size : 7 X 0.30 mm (0.50 Sq. mm)

Outer Sheath : PTFE Sheathed.

Outer Sheath Color : Grey / Blue

FEATURES

ü Operating Temp. Range : -267°C to 260°C

ü Capacitance : -15 pF/ft

ü High Temperature Resistance

ü Excellent Dielectric with Standing Properties

ü Nominal Velocity of Propagation : -67%

ü Voltage Grade : 300 Volt

ü DC Resistance at 20°C : 99.38 Ohms / Km.(Max.)

ü Excellent Mechanical Strength

ORDERING CODE

CAT5 - STP - TEF - (X) Outer Color

G - GreyB - Blue

Page 127: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

F

F3

CAT-6 UTP CABLE

CAT6UTPPVCG

UNSHIELDED TWISTED PAIR

CAT-6 STP CABLE

CAT6STPPVCG

SHIELDED TWISTED PAIR

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 23 AWG, Solid

Insulation : HDPE Insulation

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Grey / Blue

FEATURES

ü Storage Temp. Range : -20°C to 75°C

ü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 60°C

ü Capacitance : -5.6 pF/100m

ü Nominal Velocity of Propagation : -68%

ü Insulation Resistance :- 5000 Mohm / Km

ü Voltage Grade : 300 Volt

ü DC Resistance at 20°C : 93.80 Ohms / Km.(Max.)

ü Maximum DCR Unbalanced at 20°C(%) : 5

ORDERING CODE

CAT6 - UTP - PVC - (X) Outer Color

G - GreyB - Blue

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 23 AWG, Solid

Insulation Material : HDPE Insulation

Outer Shield Material : Aluminum Foil-Polyester Tape with 100 % Coverage Area

Drain Wire Material : Annealed Tinned Copper

Drain Wire Size : 7 X 0.30 mm (0.50 Sqmm)

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Grey / Blue

FEATURES

ü Storage Temp. Range : -20°C to 75°C

ü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 60°C

ü Capacitance : - 5.6 pF/100m

ü Nominal Velocity of Propagation : -67 %

ü Insulation Resistance :- 5000 Mohm / Km

ü Voltage Grade : 300 Volt

ü DC Resistance at 20°C : 99.38 Ohms / Km. (Max.)

ü Maximum DCR Unbalanced at 20°C(%) : 3

ORDERING CODE

CAT6 - STP - PVC - (X) Outer Color

G - GreyB - Blue

Page 128: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

F

F4

CAT-6 UTP CABLE

CAT6UTPTEFG

UNSHIELDED TWISTED PAIR(PTFE INSULATED)

CAT-6 STP CABLE

CAT6STPTEFG

SHIELDED TWISTED PAIR(PTFE INSULATED)

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 23 AWG, Solid

Insulation : PTFE Insulation

Outer Sheath : PTFE Sheathed

Outer Sheath Color : Grey / Blue

FEATURES

ü Operating Temp. Range : -267 °C to 260 °C

ü Capacitance : - 15 pF/ft

ü Nominal Velocity of Propagation : - 70 %

ü Voltage Grade : 300 Volt

ü High Temperature Resistance

ü Excellent Dielectric with Standing Properties

ü DC Resistance at 20°C : 99.38 Ohms / Km. (Max.)

ü Excellent Mechanical Strength

ORDERING CODE

CAT6 - UTP - TEF - (X) Outer Color

G - GreyB - Blue

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Solid Annealed Bare Copper Conductor

Conductor Size : 23 AWG, Solid

Insulation Material : PTFE Insulation

Outer Shield Material : Polymide Backed Aluminum Foil-Polyester Tape with 100% Coverage Area

Drain Wire Material : Annealed Tinned Copper

Drain Wire Size : 7 X 0.30 mm (0.50 Sqmm)

Outer Sheath : PTFE Sheathed

Outer Sheath Color : Grey / Blue

FEATURES

ü Operating Temp. Range : -267°C to 260°C

ü Capacitance : - 15 pF/ft

ü High Temperature Resistance

ü Excellent Dielectric with Standing Properties

ü Nominal Velocity of Propagation : - 67%

ü Voltage Grade : 300 Volt

ü DC Resistance at 20°C : 99.38 Ohms / Km. (Max.)

ü Excellent Mechanical Strength

ORDERING CODE

CAT6 - STP - TEF - (X) Outer Color

G - GreyB - Blue

Page 129: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

F

F5

PROFIBUS DP CABLE

PDPPEBC022P

PROFIBUS PA CABLE

PPAPEBC016P

Profibus cable is a type of bus cable popularly

used in discrete manufacturing and process

control applications. Profibus cable facilitates

communication between automation systems

and decentralized peripheral equipment.

Due to its double screening it is suitable for

installation in EMC demanding areas.

PROFIBUS PA (Process Automation) is used to

monitor measuring equipment via a process

control system in process automation

applications. Profibus cable is used for the

cabling of industrial field bus systems particularly

developed for process automation and

instrumentation application in hazardous and

intrinsically safe areas.

AVAILABLE OPTIONSFEATURESü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 80°C

ü Diamter :- 7.90 mm

ü Minimum Bending Radius :- 7 X Outer Diameter

ü Conductor Resistance at 20°C :- 110 Ohm/Km

ü Inductance :- 0.9 mH/Km

ü Mutual Capacitance :- 30nF/Km

ü Voltage Grade : 300 Volt

ü Impedance : - 150 Ohm +/- 15 Ohm

ü Voltage Grade : 300 Volt

ü Impedance : - 150 Ohm +/- 15 Ohm

SPECIFICATIONS Conductor Type : Electrolytic Solid Annealed Bare Copper

Conductor

Conductor Size : AWG 22 (0.643 mm)

Insulation Material : HDPE Insulation

Outer Shield Material : Aluminum Foil-Polyester Tape with 100% Coverage Area

Outer Braiding : Annealed Tinned Copper Braided

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Purple / Blue

ORDERING CODE

PDP - PE - BC0 - 22 - (X) Outer Color

P - PurpleB - Blue

AVAILABLE OPTIONSFEATURESü Installation Temp. Range : 0 °C to 60°C

ü Operating Temp. Range : 20°C to 80°C

ü Diameter : 7.60 mm, 9.40 mm & 11.50 mm for AWG 18,16 & 24 Respectively with ±0.50 mm Tolerance

ü Minimum Bending Radius : 7.5 X Outer Diameter

ü Inductance: - 0.7 mH/Km

ü Mutual Capacitance: - 60nF/Km

ü Voltage Grade: 300 Volt

ü Impedance: - 100 Ohm +/- 20 Ohm

SPECIFICATIONS Conductor Type : Electrolytic Stranded Annealed Bare

Copper Conductor

Conductor Size : AWG 18, 16, 14

Insulation Material : HDPE Insulation

Outer Shield Material : Aluminum Foil-Polyester Tape with 100 % Coverage Area

Drain Wire Material : Annealed Tinned Copper

Drain wire Size : 7 X 0.30 mm (0.50 Sqmm)

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Purple/ Blue

ORDERING CODE

PPA - PE - BC0 - 22 - (X) Outer Color

P - PurpleB - Blue

Page 130: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

F

Page 131: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

Special Cables G

Page 132: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 133: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G1

COMPOSITE VGA CABLE

LOAD CELL CABLE

LTFBC02406T

VGA Composite cable is used for multiple purposes i.e. for temperature measuring, for pyrometer connection or signal transmission & for camera connection.VGA Composite cable is specially designed for Pyrometer application. It is combination of thermocouple cable, VGA Cable and signal cable. In this cable centre wire is VGA cable and around this 1 pair of thermocouple cable and 9 cores of signal cable are twisted together.

Tempsens provide Load cell cables generally of 4 cores and 6 cores. In industries multiple load cells are need to be connected together by Parallel or serial connection for that Load cell cables are required. A six wire load cell cable, besides having +/- excitation and +/- signal lines also has +/- sense lines. It is a common misconception that the possibility to sense the actual voltage at the load cell is the only difference between 4 wire and 6 wire load cell cable.

AVAILABLE OPTIONS

SPECIFICATIONS

VGA Cable : Electrolytic Silver Plated Copper Clad Steel

Conductor Size : AWG 26/7/34

Insulation : FEP Insulated

Screening : Silver Plated Copper Screen

Sheathing : FEP Insulation

Thermocouple Cable (“K” Type Thermocouple Cable)

Conductor : “K” Type Extension Cable

Conductor Size : 0.75 Sq. mm

Signal Cable (9 Core)

Conductor : Annealed Tinned Plated Copper

Conductor Size : 0.75 Sqmm

Insulation : Silicon Insulated

Overall Jacket : Silicon Sheathed

FEATURES

ü Used for Multiple Purpose

ü Operating Temp. Range : 200°C

ü Diameter : - 14.00 mm

ü Conductor resistance (VGA Cable) :- 140ohms/Km (Max.)

ü Thermocouple Conductor Resistance at 20°C : - 1.35 KOhm/Km(For Loop)

ü Conductor Resistance (Signal Cable) :- 26.0 Ohm/Km (Max.)

ü Voltage Grade : 300 Volt

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Stranded Annealed Bare Copper Conductor, Tinned Plated Copper, Nickel Plated Copper, Silver Plated Copper

Conductor Size : AWG 24,22,20,18

Insulation Material : PVC / PTFE / PE

Isolator : Polymide Tape / Polyester Tape

Foil Shield (Optional) : Aluminum foil with drain wire

Overall Metal Shielding : Tinned Plated Copper Shielding / Bare Copper Shielding

FEATURES

üOperating Temp. Range : For PVC Cable up to 85°C

üOperating Temp. Range : For PTFE Cable up to 260°C

üConductor Resistance at 20°C : - As per Table 4

üRFI and EMI protected

üWater Resistance

üExcellent durability

üCustom design

üVoltage Grade : 300 Volt

üSuperior chemical and abrasion resistance.

ORDERING CODE

(LXX)

P0PET0TF

Type ofInsulation

(XXX)

BC0NPCTPCSPC

Type of Conductor

(XX)

2422201816

Conductor Size(AWG)

(XX)

040607

Number Of Core

(X)

T-(Twisted)

Cable Formation

Note : P0 (PVC), PE (Polyethylene),T0 (PTFE), TF (FEP)BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)

G

Page 134: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G2

COMPOSITE CABLE

Composite cables are the best way to integrate several cables that run between common destinations. Combine cable elements under a common jacket or shielding & save the total installation cost through the faster, easier installation of one cost efficient cable. Providing us with the application environment of the overall cable or simply select from any of the option listed here.Composite cables can be constructed as per customer designed or according to application.

ARMOURING OPTION

ü Galvanized Iron Armouring (Only for thermoplastic Insulated Cable)

ü Stainless Steel Wire Biding

Power Cable

K Type Thermocouple Cable

Signal Cable

Connecting Leads for Panel

Overall Shielding

Outer Jacket

INSULATION SELECTION

ü

ü

ü

ü

Bare Copper Thermocouple Extension Alloys SolidTinned Plated Copper Compensating Alloys StrandedNickel Plated Copper Flexible StrandedSilver Plated Copper Extra Flexible Stranded

WIRE SELECTION

ü Thermoplastic Insulation (PVC, HR PVC, FR PVC, FRLS PVC, LSZH PVC, PE)

ü Electromeric Insulation (Silicon, Neoprene, XLPE, EPR Insulation)

ü Fluoro Polymer Insulation (PTFE, FEP, PFA, ETFE, MFA)

ü High Temperature Insulation (Fiber Glass, Ceramic Fiber, Alumina Fiber, Polymide, Asbestos, Mica)

ü Special Insulation PEEK (Poly Ether Ether Ketone Insulation)

ü Polyester backed Almylar tape with ATC Drain wire

ü Polymide backed Almylar tape with ATC Drain wire

ü Annealed Bare Copper Braiding

ü Tinned Plated Copper Braiding

ü Nickel Plated Copper Braiding

ü Silver Plated Copper Braiding

ü Copper Tape Shielding

SHIELDING SELECTION INSULATION SELECTION

INNER & OUTER SHEATHING MATERIAL

ü Same as above Insulation material except Polymide, PE, XLPE, Mica Insulation

G

Page 135: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G3

HIGH TEMPERATURE CABLE

HTMINPC10RE

FLAT HEATING CABLE

FHSNA4004RE

Tempsens provide high temperature with fire

resistance cable. It has excellent features to

resist against fire In this type of cable 6 times of

Mica tapping works as a fire barrier tape &

having coloured fiber glass shethed at outer

sheath.

It is special designed flat cable named SEMOT

heater. It is also known as Heat tracer. In this

special cable 4 heating conductor parallely are

sheathed by silicon insulation. According to

resistance different Sqmm of heating wire are used

with fiber thread

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor Type : Electrolytic Stranded Nickel Plated Copper Conductor

Conductor Size : 4.00 Sqmm

Insulation Material : 6 times Mica Tapping & Impregnated colored Fiber Glass Insulation

Filler Material : High Temperature fiber glass filler

Outer Sheath : >6 times of Mica Tapping / Impregnated colored fiber glass.

FEATURES

ü Operating Temp. Range : 700°C

ü Zero Flame Cable

ü Excellent Resistance against Fire

ü Excellent Resist against chemical and corrosion.

ü Excellent fire retardant properties

ü Voltage Grade : 1100 Volt

ü Excellent Dielectric Strength

ü Excellent Abrasion Resistance

ü Colored fiber glass sheathed

ORDERING CODE

(HT-MI)

Type of Insulation

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

1816141210

Conductor Size(AWG)

(XX)

040607

Number Of Core

(XX)

REYEBKBLGN

Color

Note : BC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper), Pn0 (Pure Nickel)RE (Red), YE (Yellow), BK (Black), BL (Blue), GN (Green)

AVAILABLE OPTIONS

SPECIFICATIONS

Heating Wire : Nickel- Chrome Wire

Heating element Insulation : Silicon Insulation

Dimension : 10.00 MM X 4.00 MM

Permissible surface temp : -40°C to 200°C

FEATURES

ü Very flexible

ü Maximum heat transfer

ü Damp-Proof

ü Extended range of length and power rating

ü Excellent durability

ORDERING CODE

(FHS)

Type of Insulation

(NA)

Type of Conductor

(XX)

4038363432

Conductor Size(AWG)

(XX)

0203040506

Number OfElement

(XX)

REYEBKBLGN

Color

Note : RE (Red), YE (Yellow), BK (Black), BL (Blue), GN (Green)

High Temperature Cable

ImpregnatedFiber Glass withRed Core

Six Layer of Mica Insulation

Six Layer of Mica Insulation thenImpregnated fiberglass with 1 CoreYellow and 1 coreBlue

G

Page 136: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G4

MODBUS CABLE

MDPETPC224G

Modbus provides a master/slave communication between intelligent automation devices. the Modbus cable has an increased jacket thickness to ensure a correct termination into the Modbus connectors.

A VGA (Video Graphics Array) cable is a lead used for transmitting video signals, and it is most commonly used to link computers with monitors. Some high definition televisions use this type of cable as well. They carry analog signals rather than digital signals. It supports resolutions of up to 640 by 480 pixels, or the smallest elements in a digital image. Tempsens provide VGA cable with wide temperature range up to 260 °C.

AVAILABLE OPTIONSFEATURESü Storage Temp. Range : -20°C to 75°C

ü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 60°C

ü Capacitance (Conductor To Conductor) - 11 pF/ft

ü Capacitance (Conductor To Shield) - 21 pF/ft

ü Nominal Velocity of Propagation : - 78%

ü Voltage Grade : 300 Volt

ü Impedance : - 120 Ohm

ü DC Resistance at 20°C : 56.10 Ohms / Km.(Max.)

SPECIFICATIONS Conductor Type : Electrolytic Stranded Annealed Tinned Copper

Conductor

Conductor Size : AWG 22/7/30, Stranded

Insulation Material : HDPE Insulation

Outer Shield Material : Aluminum Foil-Polyester Tape with 100% Coverage Area

Drain Wire Material : Annealed Tinned Copper

Drain wire Size : 7 X 0.30 mm (0.50 Sq. mm)

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Grey / Blue

VGA CABLE

VGATFSPC24B

AVAILABLE OPTIONSFEATURES

ü Operating Temp. Range : -267°C to 260°C

ü Voltage Grade : 300 Volt

ü Support up to 16 different colors in digital images

ü Support resolution up to 640 X 480 pixels

ü Excellent signal transmission rate for a short distance

ü Excellent Resist to oil, chemical &a water

ü Excellent Abrasion Resistance

ü Excellent durability

SPECIFICATIONS

Conductor Type : Electrolytic Stranded Silver Plated Copper Conductor

Conductor Size : AWG 26, 24, 22, 20

Insulation Material : PTFE / FEP Insulation

Shielding : Silver Plated Copper Shielding (With > 80% Coverage Area)

Outer Sheath : PTFE Insulation

Outer Sheath Color : White / Black

ORDERING CODE

(VGA)

CableType

(XX)

T0TF

Type of Insulation

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

26242220

Conductor Size(AWG)

(X)

BW

Color

Note :ŸT0 (PTFE), TF (FEP)ŸBC0 (Bare Copper), NPC (Nickel Plated

Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)

ŸB (Black), W (White)

Pair No. Colour

1

2

3

4

White & Blue

White & Orange

White & Green

White & Brown

ORDERING CODE

(MD-PE)

Type of Insulation

(XXX)

BC0NPCSPCPN0

Type of Conductor

(XX)

1816141210

Conductor Size(AWG)

(XX)

040607

Number Of Core

(XX)

REYEBKBLGN

Color

Note :

ŸBC0 (Bare Copper), NPC (Nickel Plated Copper), TPC (Tin Plated Copper), SPC (Silver Plated Copper)

ŸRE (Red), YE (Yellow), BK (Black), BL (Blue), GN (Green)

G

Page 137: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G5

RG 11/U CABLE

RG11UPEBC0B

RG 11/U CABLE (ARMOURED)

RG11APEBC0B

RG 11/U Coaxial Cable is ideal for improved

audio and video performance in home theater

applications. End-users of RG 11/U Coaxial

Cables benefit from higher signal quality for

television, cable and internet transmission and

increased safety.

RG-11/U is also available with Galvanized Iron

armouring. Armouring is provided for better

mechanical strength.

AVAILABLE OPTIONSFEATURESü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 80°C

ü Diameter : - 10.00 mm

ü Conductor Resistance at 20°C : - 8.6 Ohm/Km

ü Attenuation (dB/Km) At 50 MHZ : - 3.2

ü Attenuation (dB/Km) At 100 MHZ : - 4.5

ü Attenuation (dB/Km) At 200 MHZ : - 7.2

ü Capacitance : - 57pF/Km

ü Voltage Grade : 300 Volt

ü Impedance: - 75 Ohm +/- 3 Ohm

SPECIFICATIONS Conductor Type : Electrolytic Solid Annealed Bare Copper

Conductor

Conductor Size : AWG 14 (1.63 mm)

Insulation Material : Solid PE Insulation

Outer Shield Material : Aluminum Foil + Aluminum Alloy Braiding

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Black

AVAILABLE OPTIONSFEATURESü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 80°C

ü Diameter : - 15.00 mm

ü Conductor Resistance at 20°C : - 8.6 Ohm/Km

ü Attenuation (dB/Km) At 50 MHZ : - 3.2

ü Attenuation (dB/Km) At 100 MHZ : - 4.5

ü Attenuation (dB/Km) At 200 MHZ : - 7.2

ü Capacitance : - 57pF/Km

ü Voltage Grade: 300 Volt

ü Impedance : - 75 Ohm +/- 3 Ohm

SPECIFICATIONS Conductor Type : Electrolytic Solid Annealed Bare Copper

Conductor

Conductor Size : AWG 14 (1.63 mm)

Insulation Material : Solid PE Insulation

Outer Shield Material : Aluminum Foil + Aluminum Alloy Braiding

Inner Sheath : PVC / FR PVC / FRLS PVC

Armouring : Galvanized Iron Round wire 0.90 mm

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Black

ORDERING CODE

RG - 11 - U - PE - (XXX) - B

Type of Conductor

BC0TPCCCS

Note :ŸBC0 (Bare Copper), TPC (Tin Plated

Copper), CCS (Copper Clad Steel)

ORDERING CODE

RG - 11 - A - PE - (XXX) - B

Type of Conductor

BC0TPCCCS

Note :ŸBC0 (Bare Copper), TPC (Tin Plated

Copper), CCS (Copper Clad Steel)

G

Page 138: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G6

RG 59/U CABLE

RG59UPEBC0B

RG 59/U CABLE (ARMOURED)

RG59APEBC0B

RG-59/U is a specific type of coaxial cable,

often used for low-power video and RF signal

connections. Used to carry base band video in

close circuit television previously used for cable

television and CCTC camera. In general, it has

poor shielding but will carry an HQ HD signal or

video over short distance.Armouring is provided

for better mechanical strength.

RG-59/U is also available with Galvanized Iron

armouring. Armouring is provided for better

mechanical strength.

AVAILABLE OPTIONSFEATURESü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 80°C

ü Diameter : - 6.10 mm

ü Conductor Resistance at 20 °C : - 26.1 Ohm/Km

ü Attenuation (dB/Km) At 50 MHZ : - 7.1

ü Attenuation (dB/Km) At 100 MHZ : - 11.3

ü Attenuation (dB/Km) At 200 MHZ : - 16.5

ü Capacitance : - 67pF/Km

ü Voltage Grade : 300 Volt

ü Impedance : - 75 Ohm +/- 3 Ohm

SPECIFICATIONS Conductor Type : Electrolytic Solid Annealed Bare Copper

Conductor

Conductor Size : AWG 22

Insulation Material : Solid PE Insulation

Outer Shield Material : Aluminum Foil + Aluminum Alloy Braiding

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Black

AVAILABLE OPTIONSFEATURESü Installation Temp. Range : 0°C to 60°C

ü Operating Temp. Range : -20°C to 80°C

ü Diameter : - 11.00 mm

ü Conductor Resistance at 20°C : - 26.1 Ohm/Km

ü Attenuation (dB/Km) At 50 MHZ : - 7.8

ü Attenuation (dB/Km) At 100 MHZ : - 11.3

ü Attenuation (dB/Km) At 200 MHZ : - 16.5

ü Capacitance : - 67pF/Km

ü Voltage Grade : 300 Volt

ü Impedance : - 75 Ohm +/- 3 Ohm

SPECIFICATIONS Conductor Type : Electrolytic Solid Annealed Bare Copper

Conductor

Conductor Size : AWG 22 (0.64 mm)

Insulation Material : Solid PE Insulation

Outer Shield Material : Bare Copper Braiding

Inner Sheath : PVC / FR PVC / FRLS PVC

Armouring : Galvanized Iron Round wire 0.90 mm

Outer Sheath : PVC / FR PVC / FRLS PVC

Outer Sheath Color : Black

ORDERING CODE

RG - 59 - U - PE - (XXX) - B

Type of Conductor

BC0TPCCCS

Note :ŸBC0 (Bare Copper), TPC (Tin Plated

Copper), CCS (Copper Clad Steel)

ORDERING CODE

RG - 59 - A - PE - (XXX) - B

Type of Conductor

BC0TPCCCS

Note :ŸBC0 (Bare Copper), TPC (Tin Plated

Copper), CCS (Copper Clad Steel)

G

Page 139: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G7

LANCE CABLE

Compensating Lance cable is used to connecting the immersion lance to the measuring instruments.

Tempsens manufactures S Type & B Type 4 core Lance cable. It is a composite type cable in which both Oxygen PPM

Measurement or signal transmission and temperature measurement work can be done at the same time by single cable called

Lance Cable.

LNCTF1604CS

SPECIFICATIONS Conductor : 'S'/”B” Type Compensating Grade Conductor (2

Conductor), Annealed Bare Copper Conductor (2 Conductors)

Conductor Size : Stranded 1.50 Sq. mm

Core Insulation : FEP / Fiber Glass Braided

Screening : Polymide Backed Almylar Screen with 100 % Coverage area

Sheathing : Fiber Glass Insulation with high temp. Varnish.

Pair Color

Pair 1 : Red (+), Green (-) for Temp. Measurement

Pair 2 : Black (+), White (-) for Oxygen PPM Measurement or signal transmission

Outer Sheath Color : Green / Grey

AVAILABLE OPTIONSFEATURESü Max. Temp. Up to 400°C

ü Excellent Heat Resistant

ü Excellent Abrasion Resistance

ü Excellent Flame Retardant

ü Good Thermal Stability

ü Excellent Chemical Resistivity

AVAILABLE OPTIONSAVAILABLE OPTIONSü Color code as per Customer Requirement

ü Metal Shielding

ü Metal Covering

ORDERING CODE

(XX)

TFT0PF

Type of Insulation

(XX)

2422201816

Conductor Size(AWG)

(XX)

020406

No. OfCore

(XX)

CS

CoreColor

Note :ŸTF (FEP), T0 (PTFE), PF (PFA), ŸCS (Customer Specification)

G

Page 140: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

G8

Electrically radiated noise frequently present in factory floor environments can interfere with device to device communication

circuit, causing delayed signals & data loss. So to keep away from these problems RS 485 cable with low capacitance, high quality

& specific impedance are used for RS-232/RS-422 and RS 485 communication application in industrial networking field. Overall

Armoring of Stainless Steel wire Braiding

RG 485 CABLE1 Pair 2 Pair 3 Pair

Construction

24 AWG 7-strand tinned copper; 1 twisted pair; overall foil and tinned

copper braid shielding; PVC jacket.

24 AWG 7-strand tinned copper; 2 twisted pairs; overall foil and tinned

copper braid shielding; PVC jacket.

24 AWG 7-strand tinned copper; 3 twisted pairs; overall foil and tinned

copper braid shielding; PVC jacket.

Insulation Polyethylene Polyethylene PolyethylenePolyethylene Polyethylene Polyethylene

Part 1

White/Blue Line & Blue/White Line

White/Blue Line & Blue/White Line

White/Blue Line & Blue/White Line

Part 1

N/AWhite/Orange Line & Orange/White Line

White/Orange Line & Orange/White Line

Part 1

N/A N/AWhite/Green Line & Green/White Line

Part 1

Assembly

1 twisted pair, overall foil tape shield and >85% Tin

Plated Copper braid, jacket

2 Twisted pairs cabled; overall foil tape shield and >85% Tin Plated Copper

braid, jacket

3 Twisted pairs cabled; overall foil tape shield and

>85% Tinned Plated Copper braid, jacket

Shield/Drain

Overall foil shield & 24 AWG strand tinned copper

drain wire, plus 85% tinned copper drain braid

Overall foil shield & 24 AWG strand tinned copper

drain wire, plus 85% tinned copper drain braid

Overall foil shield & 24 AWG strand tinned copper

drain wire, plus 85% tinned copper drain braid

Jacket Gray PVC Gray PVC Gray PVC

Diameter 5.99mm Nominal 8.96mm Nominal 9.65mm Nominal

Min. Bend Radius 63.5mm (Install) 91.44mm (Install) 96.52mm (Install)

Impedance 120Ω 120Ω 120Ω

Capacitance 52 pF/mtr Nom. 52 pF/ft Nom. 52 pF/ft Nom.

Resistance27.2Ω DC per 1000 ft @

20°C (68°) max27.2Ω DC per 1000 ft @

20°C (68°) max27.2Ω DC per 1000 ft @

20°C (68°) max

Attenuation0.6 dB/100 ft @ 1 MHz

(Nominal)0.6 dB/100 ft @ 1 MHz

(Nominal)0.6 dB/100 ft @ 1 MHz

(Nominal)

Velocity of propagation

66.20% 66.20% 66.20%

Max. Current2.1 Amps per conductor

@ 25°C (77°F) (Maximum 2.1 Amps per conductor

@ 25°C (77°F) (Maximum 1.54 Amps per conductor @ 25°C (77°F) (Maximum

Voltage Grade 300V 300V 300V

RS 485 CABLE

RS485TPC03G

ORDERING CODE

RG - 485 - TPC - XX - G

No. of Pair

010203

G

Page 141: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 142: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 143: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H1

LEAD WIRE

LPK-101

PEEK INSULATED - 260°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, TPC, NPC, SPC)

Insulation : Extruded PEEK Insulated

Voltage Rating : Up to 1.1 KV

Operating Temp. : 260°C

FEATURES

ü Max. Temp. Up to 260°C

ü Excellent Mechanical Properties

ü Excellent Radiation Resistance

ü Excellent Resist to Oil, Moist, Fluids and Chemicals

ü Excellent Di-electric Properties

ü High Temperature & Voltage Rating

ü Excellent Flame Retardant

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

S.No.Size

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

SWG AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

Max Weight gm/mtr

LPK101 26 19/38 19/0.10 0.51 0.149 1.01 1.11 1.15 1.27 1.41 1.51 125 3LPK102 24 1/24 1/0.51 0.51 0.204 1.01 1.11 1.15 1.27 1.41 1.51 87 4LPK103 24 7/32 7/0.20 0.61 0.219 1.11 1.21 1.25 1.37 1.51 1.61 82 4LPK104 24 19/36 19/0.13 0.64 0.252 1.14 1.24 1.28 1.40 1.54 1.64 79 4LPK105 22 1/22 1/0.64 0.64 0.321 1.14 1.24 1.28 1.40 1.54 1.64 55 7.3LPK106 22 7/30 7/0.25 0.76 0.343 1.26 1.36 1.40 1.52 1.66 1.76 52 7.3LPK107 22 19/34 19/0.16 0.81 0.382 1.31 1.41 1.45 1.57 1.71 1.81 49 7.3LPK118 20 1/20 1/0.81 0.81 0.515 1.31 1.41 1.45 1.57 1.71 1.81 34 11LPK109 20 7/28 7/0.32 0.97 0.562 1.47 1.57 1.61 1.73 1.87 1.97 32 11LPK110 20 19/32 19/0.20 1.02 0.596 1.52 1.62 1.66 1.78 1.92 2.02 30 11LPK111 18 7/26 7/0.40 1.22 0.879 1.86 2.08 2.12 2.22 20 16LPK112 18 19/30 19/0.25 1.27 0.932 1.91 2.13 2.17 2.27 18 16LPK113 16 19/29 19/0.29 1.45 1.254 2.09 2.31 2.35 2.55 14 22LPK114 15 19/28 19/0.32 1.6 1.528 2.24 2.46 2.50 2.70 12 26LPK115 14 19/27 19/0.36 1.83 1.933 2.47 2.69 2.73 2.93 9 32LPK116 13 19/26 19/0.40 2 2.387 2.64 2.86 2.90 3.10 7 35LPK117 12 19/25 19/0.45 2.31 3.021 2.95 3.17 3.21 3.41 5 41LPK118 12 37/28 37/0.32 2.26 2.975 2.90 3.12 3.16 3.36 6 41LPK119 11 19/24 19/0.50 2.5 3.73 3.14 3.36 3.40 3.60 4 45LPK120 10 19/22 19/0.65 3.35 6.304 3.99 4.21 4.25 4.45 2 55LPK121 10 37/26 37/0.4 2.82 4.649 3.46 3.68 3.72 3.92 3 50

3.784.274.655.025.646.136.607.808.629.08

12.0612.6616.6019.4723.7228.2634.8034.2441.6867.1050.80

H

Page 144: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H2

LEAD WIRE

LT-101

PTFE INSULATED - 260°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC)

Insulation : PTFE Insulated

Voltage Rating : Up to 1.1 KV

Operating Temp. : 260°C

Color Code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 260°C

ü Good Chemical Resistant

ü Low Dielectric Constant

ü Very Low dissipation factor

ü High Temperature Resistant

ü Good Abrasion Resistance

ü Non-Flammability

ü Passes JSS 51034 Flame Test

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

ü Fiber Braiding

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

S.No.Size

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

SWG AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

LT101 32 7/40 7/0.08 0.25 0.035 0.5 0.59 0.66 0.87 0.91 1.11 567 0.7LT102 30 1/30 1/0.25 0.25 0.049 0.5 0.59 0.66 0.87 0.91 1.11 354 1LT103 30 7/38 7/0.10 0.31 0.055 0.56 0.65 0.72 0.93 0.97 1.17 330 1LT104 28 1/28 7/0.32 0.32 0.08 0.57 0.66 0.73 0.94 0.98 1.18 223 2.1LT105 28 7/36 7/0.13 0.38 0.093 0.63 0.72 0.79 1 1.04 1.24 209 2.1LT106 26 1/26 1/0.40 0.4 0.125 0.65 0.74 0.81 1.02 1.06 1.26 140 3LT107 26 7/34 7/0.16 0.48 0.14 0.73 0.82 0.89 1.1 1.14 1.34 132 3LT108 26 19/38 19/0.10 0.51 0.149 0.76 0.85 0.92 1.13 1.17 1.37 125 3LT109 24 1/24 1/0.51 0.51 0.204 0.76 0.85 0.92 1.13 1.17 1.37 87 4LT110 24 7/32 7/0.20 0.61 0.219 0.86 0.95 1.02 1.23 1.27 1.47 82 4LT111 24 19/36 19/0.13 0.64 0.252 0.89 0.98 1.05 1.26 1.3 1.5 79 4LT112 22 1/22 1/0.64 0.64 0.321 0.89 0.98 1.05 1.26 1.3 1.5 55 7.3LT113 22 7/30 7/0.25 0.76 0.343 1.01 1.1 1.17 1.38 1.42 1.62 52 7.3LT114 22 19/34 19/0.16 0.81 0.382 1.06 1.15 1.22 1.43 1.47 1.67 49 7.3LT115 20 1/20 1/0.81 0.81 0.515 1.06 1.15 1.22 1.43 1.47 1.67 34 11LT116 20 7/28 7/0.32 0.97 0.562 1.22 1.31 1.38 1.59 1.63 1.83 32 11LT117 20 19/32 19/0.20 1.02 0.596 1.27 1.36 1.43 1.64 1.68 1.88 30 11LT118 18 7/26 7/0.40 1.22 0.879 1.63 1.92 1.88 2.08 20 16LT119 18 19/30 19/0.25 1.27 0.932 1.68 1.97 1.93 2.13 18 16LT120 16 19/29 19/0.29 1.45 1.254 1.86 2.15 2.11 2.45 14 22LT121 15 19/28 19/0.32 1.6 1.528 2.01 2.3 2.26 2.6 12 26LT122 14 19/27 19/0.36 1.83 1.933 2.24 2.53 2.49 2.83 9 32LT123 13 19/26 19/0.40 2 2.387 2.41 2.7 2.66 3 7 35LT124 12 19/25 19/0.45 2.31 3.021 2.72 3.01 2.97 3.31 5 41LT125 12 37/28 37/0.32 2.26 2.975 2.67 2.96 2.92 3.26 6 41LT126 11 19/24 19/0.50 2.5 3.73 2.91 3.2 3.16 3.5 4 45LT127 10 19/22 19/0.65 3.35 6.304 3.76 4.05 4.01 4.35 2 55LT128 10 37/26 37/0.4 2.82 4.649 3.23 3.52 3.48 3.82 3 50LT129 8 133/29 133/0.29 4.29 8.784 4.95 5.29 2 75LT130 6 133/27 133/0.36 5.8 13.537 6.46 6.8 1 100

Max weightgm/mtr

2.332.462.692.953.243.593.964.134.635.065.456.076.627.128.329.229.67

12.8113.4418.0221.0125.4430.1236.8936.3143.9370.0353.3195.60

143.59

H

Page 145: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H3

LEAD WIRE

LTF-101

FEP INSULATED - 200°C

JSS 51034, IS 8130

Voltage Grade : 600/1100V

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC, TPC)

Insulation : Extruded FEP Insulated

Voltage Rating : Up to 1.1 KV

Operating Temp. : 200°C

Color Code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 200°C

ü Uniform Diameter

ü Smooth Surface

ü Strong Bonding Between Insulation & Core Conductor

ü Low Dielectric Constant

ü Easy Stripping

ü Can be Produce in Continuous Length

ü Available in Different colors

ü 250 V / 600 V / 1100 V as per Customer Requirement

ü Metal Covering

ü Fiber Braiding

CONSTRUCTION DETAILS AND DIMENSIONS

S.No.Size

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

SWG AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

LTF101 26 1/26 1/0.40 0.4 0.125 0.65 0.74 0.81 1.02 1.06 1.26 140 3L 102TF 26 7/34 7/0.16 0.48 0.14 0.73 0.82 0.89 1.1 1.14 1.34 132 3L 103TF 26 19/38 19/0.10 0.51 0.149 0.76 0.85 0.92 1.13 1.17 1.37 125 3L 104TF 24 1/24 1/0.51 0.51 0.204 0.76 0.85 0.92 1.13 1.17 1.37 87 4L 105TF 24 7/32 7/0.20 0.61 0.219 0.86 0.95 1.02 1.23 1.27 1.47 82 4L 106TF 24 19/36 19/0.13 0.64 0.252 0.89 0.98 1.05 1.26 1.3 1.5 79 4L 107TF 22 1/22 1/0.64 0.64 0.321 0.89 0.98 1.05 1.26 1.3 1.5 55 7.3L 108TF 22 7/30 7/0.25 0.76 0.343 1.01 1.1 1.17 1.38 1.42 1.62 52 7.3L 109TF 22 19/34 19/0.16 0.81 0.382 1.06 1.15 1.22 1.43 1.47 1.67 49 7.3L 110TF 20 1/20 1/0.81 0.81 0.515 1.06 1.15 1.22 1.43 1.47 1.67 34 11L 111TF 20 7/28 7/0.32 0.97 0.562 1.22 1.31 1.38 1.59 1.63 1.83 32 11L 112TF 20 19/32 19/0.20 1.02 0.596 1.27 1.36 1.43 1.64 1.68 1.88 30 11L 113TF 18 7/26 7/0.40 1.22 0.879 1.63 1.92 1.68 2.08 20 16L 114TF 18 19/30 19/0.25 1.27 0.932 1.68 1.97 1.93 2.13 18 16L 115TF 16 19/29 19/0.29 1.45 1.254 1.86 2.15 2.11 2.45 14 22L 116TF 15 19/28 19/0.32 1.6 1.528 2.01 2.3 2.26 2.6 12 26L 117TF 14 19/27 19/0.36 1.83 1.933 2.24 2.53 2.49 2.83 9 32L 118TF 13 19/26 19/0.40 2 2.387 2.41 2.7 2.66 3 7 35L 119TF 12 19/25 19/0.45 2.31 3.021 2.72 3.01 2.97 3.31 5 41L 120TF 12 37/28 37/0.32 2.26 2.975 2.67 2.96 2.92 3.26 6 41L 121TF 11 19/24 19/0.50 2.5 3.73 2.91 3.2 3.16 3.5 4 45

Max Weight gm/mtr

3.593.964.134.635.065.456.076.627.128.329.229.67

12.8113.4418.0221.0125.4430.1236.8936.3143.93

L 122TF 10 19/22 19/0.65 3.35 6.304 3.76 4.05 4.01 4.35 2 55L 123TF 10 37/26 37/0.4 2.82 4.649 3.23 3.52 3.48 3.82 3 50

70.0353.31

H

Page 146: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H4

LEAD WIRE

LET-101

ETFE INSULATED - 150°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC, TPC)

Insulation : Extruded ETFE Insulated

Voltage Rating : Up to 1.1 KV

Operating Temp. : 200°C

Color code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 150°C

ü Smooth Surface

ü Strong Bonding Between Insulation & Core Conductor

ü Excellent Mechanical Properties

ü Excellent Low Temperature Characteristics

ü Excellent Resist to Moist, Fluids and Chemicals

ü Good Abrasion Resistance

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement.

ü Metal Covering

ü Fiber Braiding

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

(mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

0.4 0.125 0.65 0.74 0.81 1.02 1.06 1.26 140 30.48 0.14 0.73 0.82 0.89 1.1 1.14 1.34 132 30.51 0.149 0.76 0.85 0.92 1.13 1.17 1.37 125 30.51 0.204 0.76 0.85 0.92 1.13 1.17 1.37 87 40.61 0.219 0.86 0.95 1.02 1.23 1.27 1.47 82 40.64 0.252 0.89 0.98 1.05 1.26 1.3 1.5 79 40.64 0.321 0.89 0.98 1.05 1.26 1.3 1.5 55 7.30.76 0.343 1.01 1.1 1.17 1.38 1.42 1.62 52 7.30.81 0.382 1.06 1.15 1.22 1.43 1.47 1.67 49 7.30.81 0.515 1.06 1.15 1.22 1.43 1.47 1.67 34 110.97 0.562 1.22 1.31 1.38 1.59 1.63 1.83 32 111.02 0.596 1.27 1.36 1.43 1.64 1.68 1.88 30 111.22 0.879 1.63 1.92 1.68 2.08 20 161.27 0.932 1.68 1.97 1.93 2.13 18 161.45 1.254 1.86 2.15 2.11 2.45 14 221.6 1.528 2.01 2.3 2.26 2.6 12 26

1.83 1.933 2.24 2.53 2.49 2.83 9 322 2.387 2.41 2.7 2.66 3 7 35

2.31 3.021 2.72 3.01 2.97 3.31 5 412.26 2.975 2.67 2.96 2.92 3.26 6 412.5 3.73 2.91 3.2 3.16 3.5 4 45

3.35 6.304 3.76 4.05 4.01 4.35 2 55

S.No.

LET101L 102ETL 103ETL 104ETL 105ETL 106ETL 107ETL 108ETL 109ETL 110ETLET111L 112ETL 113ETL 114ETL 115ETL 116ETL 117ETL 118ETL 119ETL 120ETL 121ETL 122ETL 123ET

Size

SWG

2626262424242222222020201818161514131212111010

Number of Strands/Dia of each Strand

AWG (mm)

1/26 1/0.407/34 7/0.16

19/38 19/0.101/24 1/0.517/32 7/0.20

19/36 19/0.131/22 1/0.647/30 7/0.25

19/34 19/0.161/20 1/0.817/28 7/0.32

19/32 19/0.207/26 7/0.40

19/30 19/0.2519/29 19/0.2919/28 19/0.3219/27 19/0.3619/26 19/0.4019/25 19/0.4537/28 37/0.3219/24 19/0.5019/22 19/0.6537/26 37/0.4 2.82 4.649 3.23 3.52 3.48 3.82 3 50

Max Weight gm/mtr

3.033.343.493.994.354.725.345.816.287.488.278.6911.6912.2916.4919.3523.6128.1534.6834.1441.5767.0550.70

H

Page 147: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H5

LEAD WIRE

LPF-101

PFA INSULATED - 260°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC, TPC)

Insulation : Extruded PFA Insulated

Voltage rating : Up to 1.1 KV

Operating Temp. : 260°C

Color code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 260°C

ü Smooth Surface

ü Excellent Mechanical Properties

ü Highly Flame Retardant

ü Excellent resist to Oil, Moist, Fluids and Chemicals

ü Excellent Di-Electric Properties

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

ü Fiber Braiding

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

S.No.Size

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

SWG AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

LPF101 26 1/26 1/0.40 0.4 0.125 0.65 0.74 0.81 1.02 1.06 1.26 140 3L 102PF 26 7/34 7/0.16 0.48 0.14 0.73 0.82 0.89 1.1 1.14 1.34 132 3L 103PF 26 19/38 19/0.10 0.51 0.149 0.76 0.85 0.92 1.13 1.17 1.37 125 3L 104PF 24 1/24 1/0.51 0.51 0.204 0.76 0.85 0.92 1.13 1.17 1.37 87 4L 105PF 24 7/32 7/0.20 0.61 0.219 0.86 0.95 1.02 1.23 1.27 1.47 82 4L 106PF 24 19/36 19/0.13 0.64 0.252 0.89 0.98 1.05 1.26 1.3 1.5 79 4L 107PF 22 1/22 1/0.64 0.64 0.321 0.89 0.98 1.05 1.26 1.3 1.5 55 7.3L 108PF 22 7/30 7/0.25 0.76 0.343 1.01 1.1 1.17 1.38 1.42 1.62 52 7.3L 109PF 22 19/34 19/0.16 0.81 0.382 1.06 1.15 1.22 1.43 1.47 1.67 49 7.3L 110PF 20 1/20 1/0.81 0.81 0.515 1.06 1.15 1.22 1.43 1.47 1.67 34 11LPF111 20 7/28 7/0.32 0.97 0.562 1.22 1.31 1.38 1.59 1.63 1.83 32 11L 112PF 20 19/32 19/0.20 1.02 0.596 1.27 1.36 1.43 1.64 1.68 1.88 30 11L 113PF 18 7/26 7/0.40 1.22 0.879 1.63 1.92 1.68 2.08 20 16L 114PF 18 19/30 19/0.25 1.27 0.932 1.68 1.97 1.93 2.13 18 16L 115PF 16 19/29 19/0.29 1.45 1.254 1.86 2.15 2.11 2.45 14 22L 116PF 15 19/28 19/0.32 1.6 1.528 2.01 2.3 2.26 2.6 12 26L 117PF 14 19/27 19/0.36 1.83 1.933 2.24 2.53 2.49 2.83 9 32L 118PF 13 19/26 19/0.40 2 2.387 2.41 2.7 2.66 3 7 35L 119PF 12 19/25 19/0.45 2.31 3.021 2.72 3.01 2.97 3.31 5 41L 120PF 12 37/28 37/0.32 2.26 2.975 2.67 2.96 2.92 3.26 6 41L 121PF 11 19/24 19/0.50 2.5 3.73 2.91 3.2 3.16 3.5 4 45L 122PF 10 19/22 19/0.65 3.35 6.304 3.76 4.05 4.01 4.35 2 55L 123PF 10 37/26 37/0.4 2.82 4.649 3.23 3.52 3.48 3.82 3 50

Max Weight gm/mtr

3.593.964.134.635.065.456.076.627.128.329.229.67

12.8113.4418.0221.0125.4430.1236.8936.3143.9370.0353.31

H

Page 148: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H6

LEAD WIRE

LMF-101

MFA INSULATED - 260°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC, TPC)

Insulation : Extruded MFA Insulated

Voltage rating : Up to 1.1 KV

Operating Temp. : 260°C

Color code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 260°C

ü Smooth Surface

ü Excellent Mechanical Properties

ü Highly Flame Retardant

ü Excellent Resist to Oil, Moist, Fluids and Chemicals

ü Excellent Di-electric Properties

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

ü Fiber Braiding

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

1/26 1/0.40 0.4 0.125 0.65 0.74 0.81 1.02 1.06 1.26 140 37/34 7/0.16 0.48 0.14 0.73 0.82 0.89 1.1 1.14 1.34 132 3

19/38 19/0.10 0.51 0.149 0.76 0.85 0.92 1.13 1.17 1.37 125 31/24 1/0.51 0.51 0.204 0.76 0.85 0.92 1.13 1.17 1.37 87 47/32 7/0.20 0.61 0.219 0.86 0.95 1.02 1.23 1.27 1.47 82 4

19/36 19/0.13 0.64 0.252 0.89 0.98 1.05 1.26 1.3 1.5 79 41/22 1/0.64 0.64 0.321 0.89 0.98 1.05 1.26 1.3 1.5 55 7.37/30 7/0.25 0.76 0.343 1.01 1.1 1.17 1.38 1.42 1.62 52 7.3

19/34 19/0.16 0.81 0.382 1.06 1.15 1.22 1.43 1.47 1.67 49 7.31/20 1/0.81 0.81 0.515 1.06 1.15 1.22 1.43 1.47 1.67 34 117/28 7/0.32 0.97 0.562 1.22 1.31 1.38 1.59 1.63 1.83 32 11

19/32 19/0.20 1.02 0.596 1.27 1.36 1.43 1.64 1.68 1.88 30 117/26 7/0.40 1.22 0.879 1.63 1.92 1.68 2.08 20 16

19/30 19/0.25 1.27 0.932 1.68 1.97 1.93 2.13 18 1619/29 19/0.29 1.45 1.254 1.86 2.15 2.11 2.45 14 2219/28 19/0.32 1.6 1.528 2.01 2.3 2.26 2.6 12 2619/27 19/0.36 1.83 1.933 2.24 2.53 2.49 2.83 9 3219/26 19/0.40 2 2.387 2.41 2.7 2.66 3 7 3519/25 19/0.45 2.31 3.021 2.72 3.01 2.97 3.31 5 4137/28 37/0.32 2.26 2.975 2.67 2.96 2.92 3.26 6 4119/24 19/0.50 2.5 3.73 2.91 3.2 3.16 3.5 4 4519/22 19/0.65 3.35 6.304 3.76 4.05 4.01 4.35 2 55

S.No.

LMF101L 102MFL 103MFL 104MFL 105MFL 106MFL 107MFL 108MFL 109MFL 110MFL 111MFL 112MFL 113MFL 114MFL 115MFL 116MFL 117MFL 118MFL 119MFL 120MFL 121MFL 122MFL 123MF

Size

SWG

2626262424242222222020201818161514131212111010 37/26 37/0.4 2.82 4.649 3.23 3.52 3.48 3.82 3 50

Max Weight gm/mtr

3.593.964.134.635.065.456.076.627.128.329.229.67

12.8113.4418.0221.0125.4430.1236.8936.3143.9370.0353.31

H

Page 149: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H7

LEAD WIRE

LFT-101

PTFE/FIBER GLASS INSULATED - 400°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, TPC, NPC, SPC)

Insulation : PTFE / Fiber Glass with High Temperature Varnish

Voltage rating : Up to 1.1 KV

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Abrasion Resistance

ü Excellent Heat Resistivity

ü Excellent resist to Oil, moist, fluids and chemicals

ü Excellent Di-electric Properties

ü High Temperature & Voltage Rating

ü Excellent Flame Retardant

ü 250 V / 600 V / 1100 V As per Customer Requirement.

ü Metal Covering

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

S.No.

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

Max Weight gm/mtr

Size

SWG

L 101FT 19/38 19/0.10 0.51 0.149 1.21 1.41 1.57 1.71 2.01 2.11 125 3L 102FT 1/24 1/0.51 0.51 0.204 1.21 1.41 1.57 1.71 2.01 2.11 87 4L 103FT 7/32 7/0.20 0.61 0.219 1.31 1.51 1.67 1.81 2.11 2.21 82 4L 104FT 19/36 19/0.13 0.64 0.252 1.34 1.54 1.70 1.84 2.14 2.24 79 4L 105FT 1/22 1/0.64 0.64 0.321 1.34 1.54 1.70 1.84 2.14 2.24 55 7.3L 106FT 7/30 7/0.25 0.76 0.343 1.46 1.66 1.82 1.96 2.26 2.36 52 7.3L 107FT 19/34 19/0.16 0.81 0.382 1.51 1.71 1.87 2.01 2.31 2.41 49 7.3L 108FT 1/20 1/0.81 0.81 0.515 1.51 1.71 1.87 2.01 2.31 2.41 34 11L 109FT 7/28 7/0.32 0.97 0.562 1.67 1.87 2.03 2.17 2.47 2.57 32 11L 110FT 19/32 19/0.20 1.02 0.596 1.72 1.92 2.08 2.22 2.52 2.62 30 11L 111FT 7/26 7/0.40 1.22 0.879 2.28 2.68 2.72 2.82 20 16L 112FT 19/30 19/0.25 1.27 0.932 2.33 2.73 2.77 2.87 18 16L 113FT 19/29 19/0.29 1.45 1.254 2.51 2.91 2.95 3.25 14 22L 114FT 19/28 19/0.32 1.6 1.528 2.66 3.06 3.10 3.40 12 26L 115FT 19/27 19/0.36 1.83 1.933 2.89 3.29 3.33 3.36 9 32L 116FT 19/26 19/0.40 2 2.387 3.06 3.46 3.53 3.80 7 35L 117FT 19/25 19/0.45 2.31 3.021 3.37 3.77 3.81 4.11 5 41L 118FT 37/28 37/0.32 2.26 2.975 3.32 3.72 3.76 4.06 6 41L 119FT 19/24 19/0.50 2.5 3.73 3.56 3.96 4.00 4.30 4 45

6.617.107.648.068.689.369.9111.1112.1712.6816.1016.7121.9125.0629.7434.6041.7041.0648.95

L 120FT 19/22 19/0.65 3.35 6.304 4.41 4.81 4.85 5.15 2 55L 121FT

262424242222222020201818161514131212111010 37/26 37/0.4 2.82 4.649 3.88 4.28 4.32 4.62 3 50

75.9558.66

H

Page 150: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H8

LEAD WIRE

LAM-101

MICA / ALUMINA FIBER INSULATED - 1200°C

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, TPC, NPC, SPC)

Insulation : Mica / Alumina Fiber

Operating Temp. : 1200°C

FEATURES

ü Max. Temp. Up to 1200°C

ü Excellent temperature resistance

ü Excellent Abrasion Resistance

ü Excellent Heat Resistivity

IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

19/38 19/0.10 0.51 0.149 1.11 1.31 1.41 1.51 1.71 1.81 125 31/24 1/0.51 0.51 0.204 1.11 1.31 1.41 1.51 1.71 1.81 87 47/32 7/0.20 0.61 0.219 1.21 1.41 1.51 1.61 1.81 1.91 82 4

19/36 19/0.13 0.64 0.252 1.24 1.44 1.54 1.64 1.84 1.94 79 41/22 1/0.64 0.64 0.321 1.24 1.44 1.54 1.64 1.84 1.94 55 7.37/30 7/0.25 0.76 0.343 1.36 1.56 1.66 1.76 1.96 2.06 52 7.3

19/34 19/0.16 0.81 0.382 1.41 1.61 1.71 1.81 2.01 2.11 49 7.31/20 1/0.81 0.81 0.515 1.41 1.61 1.71 1.81 2.01 2.11 34 117/28 7/0.32 0.97 0.562 1.57 1.77 1.87 1.97 2.17 2.27 32 11

19/32 19/0.20 1.02 0.596 1.62 1.82 1.92 2.02 2.22 2.32 30 117/26 7/0.40 1.22 0.879 2.12 2.32 2.42 2.52 20 16

19/30 19/0.25 1.27 0.932 2.17 2.37 2.47 2.57 18 1619/29 19/0.29 1.45 1.254 2.35 2.55 2.65 2.85 14 2219/28 19/0.32 1.6 1.528 2.5 2.7 2.8 3 12 2619/27 19/0.36 1.83 1.933 2.73 2.93 3.03 3.23 9 3219/26 19/0.40 2 2.387 2.9 3.1 3.2 3.4 7 3519/25 19/0.45 2.31 3.021 3.21 3.41 3.51 3.71 5 4137/28 37/0.32 2.26 2.975 3.16 3.36 3.46 3.66 6 4119/24 19/0.50 2.5 3.73 3.4 3.6 3.7 3.9 4 45

S.No.

LAM101LAM102LAM103LAM104LAM105LAM106LAM107LAM108LAM109LAM110LAM111LAM112LAM113LAM114LAM115LAM116LAM117LAM118LAM119LAM120

Size

SWG

2624242422222220202018181615141312121110 19/22 19/0.65 3.35 6.304 4.25 4.45 4.55 4.75 2 55

Max Weight gm/mtr

4.665.155.575.956.587.127.618.819.69

10.1413.2513.8717.9020.8325.1829.7936.4535.8843.4269.20

H

Page 151: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H9

LEAD WIRE

LP-101

PVC INSULATED - 85°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, TPC)

Insulation : PVC / HR PVC / FRLS PVC

Voltage rating : Up to 1.1 KV

Operating Temp. : 85°C

Color code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 85°C

ü Smooth Surface

ü Good Flexibility

ü Excellent resist to Oil, moist, fluids and chemicals

ü Excellent Di-electric Properties

ü High Temperature & Voltage Rating

ü Excellent Flame Retardant

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement.

ü Metal Covering

IS 694, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

1/26 1/0.40 0.4 0.125 1.00 1.40 1.50 1.70 2.10 2.20 140 37/34 7/0.16 0.48 0.14 1.08 1.48 1.58 1.78 2.18 2.28 132 3

19/38 19/0.10 0.51 0.149 1.11 1.51 1.61 1.81 2.21 2.31 125 31/24 1/0.51 0.51 0.204 1.11 1.51 1.61 1.81 2.21 2.31 87 47/32 7/0.20 0.61 0.219 1.21 1.61 1.71 1.91 2.31 2.41 82 4

19/36 19/0.13 0.64 0.252 1.24 1.64 1.74 1.94 2.34 2.44 79 41/22 1/0.64 0.64 0.321 1.24 1.64 1.74 1.94 2.34 2.44 55 7.37/30 7/0.25 0.76 0.343 1.36 1.76 1.86 2.06 2.46 2.56 52 7.3

19/34 19/0.16 0.81 0.382 1.41 1.81 1.91 2.11 2.51 2.61 49 7.31/20 1/0.81 0.81 0.515 1.41 1.81 1.91 2.11 2.51 2.61 34 117/28 7/0.32 0.97 0.562 1.57 1.97 2.07 2.27 2.67 2.77 32 11

19/32 19/0.20 1.02 0.596 1.62 2.05 2.12 2.32 2.72 2.82 30 117/26 7/0.40 1.22 0.879 2.32 2.82 2.92 3.02 20 16

19/30 19/0.25 1.27 0.932 2.37 2.87 2.97 3.07 18 1619/29 19/0.29 1.45 1.254 2.55 3.05 3.15 3.45 14 2219/28 19/0.32 1.6 1.528 2.70 3.20 3.30 3.60 12 2619/27 19/0.36 1.83 1.933 2.93 3.43 3.53 3.83 9 3219/26 19/0.40 2 2.387 3.10 3.60 3.70 4.00 7 3519/25 19/0.45 2.31 3.021 3.41 3.91 4.01 4.31 5 4137/28 37/0.32 2.26 2.975 3.36 3.86 3.96 4.26 6 4119/24 19/0.50 2.5 3.73 3.60 4.10 4.20 4.50 4 4519/22 19/0.65 3.35 6.304 4.45 4.95 5.05 5.35 2 55

S.No.

LP101LP102LP103LP104LP105LP106LP107LP108LP109LP110LP111LP112LP113LP114LP115LP116LP117LP118LP119LP120LP121LP122LP123

Size

SWG

2626262424242222222020201818161514131212111010 37/26 37/0.4 2.82 4.649 3.92 4.42 4.52 4.82 3 50

Max Weight gm/mtr

6.637.107.317.818.378.799.41

10.1210.6811.8812.9813.5016.9017.5822.8225.9530.7235.6142.7742.1250.1277.2259.83

H

Page 152: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H10

LEAD WIRE

LS-101

SILICON INSULATED - 200°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC, TPC)

Insulation : Extruded Silicon Insulated

Voltage rating : Up to 1.1 KV

Operating Temp. : 200°C

Color code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 200°C

ü Smooth Surface

ü Excellent Flexibility

ü Excellent resist to Oil, moist, fluids and chemicals

ü Excellent Di-electric Properties

ü High Temperature & Voltage Rating

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

ü Fiber Braiding

JSS 51034, IS 8130

Voltage Grade : 600/1100V

CONSTRUCTION DETAILS AND DIMENSIONS

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

1/26 1/0.40 0.4 0.125 1.20 1.60 1.64 1.76 1.90 2.20 140 37/34 7/0.16 0.48 0.14 1.28 1.68 1.72 1.84 1.98 2.28 132 3

19/38 19/0.10 0.51 0.149 1.31 1.71 1.75 1.87 2.04 2.31 125 31/24 1/0.51 0.51 0.204 1.31 1.71 1.75 1.87 2.04 2.31 87 47/32 7/0.20 0.61 0.219 1.41 1.81 1.85 1.97 2.11 2.41 82 4

19/36 19/0.13 0.64 0.252 1.44 1.84 1.88 2.02 2.14 2.44 79 41/22 1/0.64 0.64 0.321 1.44 1.84 1.88 2.02 2.14 2.44 55 7.37/30 7/0.25 0.76 0.343 1.56 1.96 2.00 2.12 2.26 2.56 52 7.3

19/34 19/0.16 0.81 0.382 1.61 2.02 2.05 2.17 2.31 2.61 49 7.31/20 1/0.81 0.81 0.515 1.61 2.02 2.05 2.17 2.31 2.61 34 117/28 7/0.32 0.97 0.562 1.77 2.17 2.21 2.33 2.47 2.77 32 11

19/32 19/0.20 1.02 0.596 1.82 2.22 2.26 2.38 2.52 2.88 30 117/26 7/0.40 1.22 0.879 2.46 2.66 2.72 3.02 20 16

19/30 19/0.25 1.27 0.932 2.51 2.71 2.77 3.07 18 1619/29 19/0.29 1.45 1.254 2.69 2.89 2.95 3.45 14 2219/28 19/0.32 1.6 1.528 2.84 3.05 3.10 3.60 12 2619/27 19/0.36 1.83 1.933 3.08 3.27 3.33 3.83 9 3219/26 19/0.40 2 2.387 3.24 3.44 3.50 4.00 7 3519/25 19/0.45 2.31 3.021 3.55 3.75 3.81 4.31 5 4137/28 37/0.32 2.26 2.975 3.50 3.70 3.76 4.26 6 4119/24 19/0.50 2.5 3.73 3.74 3.94 4.00 4.50 4 4519/22 19/0.65 3.35 6.304 4.59 4.79 4.85 5.35 2 55

S.No.

LS101LS102LS103LS104LS105LS106LS107LS108LS109LS110LS111LS112LS113LS114LS115LS116LS117LS118LS119LS120LS121LS122LS123

Size

SWG

2626262424242222222020201818161514131212111010 37/26 37/0.4 2.82 4.649 4.06 7.26 4.32 4.82 3 50

Max Weight gm/mtr

6.456.917.117.618.158.579.199.89

10.4511.6612.7213.2316.6217.2822.4425.5830.2835.1442.2541.6149.5276.5459.23

H

Page 153: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H11

LEAD WIRE

LFS-101

SILICON/FIBER GLASS INSULATED - 200°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, NPC, SPC, TPC)

Insulation : Extruded Silicon / Fiber Glass with High Temp. Varnish Insulated

Voltage rating : Up to 1.1 KV

Operating Temp. : 200°C

Color code : As per Customer Requirement

FEATURES

ü Max. Temp. Up to 200°C

ü Smooth Surface

ü Excellent Flexibility

ü Excellent resist to Oil, moist, fluids and chemicals

ü Excellent Di-electric Properties

ü High Temperature & Voltage Rating.

ü Good heat resistivity

ü Available in Different colors

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

CONSTRUCTION DETAILS AND DIMENSIONS

IS 9968, IS 8130

Voltage Grade : 600/1100V

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

19/38 19/0.10 0.51 0.149 1.51 1.91 2.01 2.11 2.31 2.71 125 31/24 1/0.51 0.51 0.204 1.51 1.91 2.01 2.11 2.31 2.71 87 47/32 7/0.20 0.61 0.219 1.61 2.01 2.11 2.41 2.81 82 4

19/36 19/0.13 0.64 0.252 1.64 2.04 2.14 2.24 2.44 2.84 79 41/22 1/0.64 0.64 0.321 1.64 2.04 2.14 2.24 2.44 2.84 55 7.37/30 7/0.25 0.76 0.343 1.76 2.16 2.26 2.36 2.56 2.96 52 7.3

19/34 19/0.16 0.81 0.382 1.81 2.21 2.31 2.41 2.61 3.01 49 7.31/20 1/0.81 0.81 0.515 1.81 2.21 2.31 2.41 2.61 3.01 34 117/28 7/0.32 0.97 0.562 1.97 2.37 2.47 2.57 2.77 3.17 32 11

19/32 19/0.20 1.02 0.596 2.02 2.42 2.52 2.62 2.82 3.22 30 117/26 7/0.40 1.22 0.879 2.72 2.96 3.02 3.42 20 16

19/30 19/0.25 1.27 0.932 2.77 3.01 3.07 3.47 18 1619/29 19/0.29 1.45 1.254 2.95 3.19 3.25 3.85 14 2219/28 19/0.32 1.6 1.528 3.1 3.34 3.4 4 12 2619/27 19/0.36 1.83 1.933 3.33 3.57 3.63 4.23 9 3219/26 19/0.40 2 2.387 3.5 3.74 3.8 4.4 7 3519/25 19/0.45 2.31 3.021 3.81 4.05 4.11 4.71 5 4137/28 37/0.32 2.26 2.975 3.76 4 4.06 4.66 6 4119/24 19/0.50 2.5 3.73 4 4.24 4.3 4.9 4 45

S.No.

LFS101LFS102LFS103LFS104LFS105LFS106LFS107LFS108LFS109LFS110LFS111LFS112LFS113LFS114LFS115LFS116LFS117LFS118LFS119LFS120

Size

SWG

2624242422222220202018181615141312121110 19/22 19/0.65 3.35 6.304 4.85 5.09 5.15 5.75 2 55

Max Weight gm/mtr

9.139.62

10.2410.6811.3012.0812.6713.8715.0715.6219.1319.8525.2728.5233.3838.3645.7045.0353.0980.74

2.21

H

Page 154: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H12

LEAD WIRE

LK-101

POLYMIDE INSULATED - 316°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, TPC, NPC, SPC)

Insulation : Wrapped & Sintered Polymide tape Insulated

Voltage rating : Up to 1.1 KV

Operating Temp. : 316°C

FEATURES

ü Max. Temp. Up to 316°C

ü Excellent Mechanical Properties

ü Max. Temp. Up to 316°C

ü High Temperature withstanding

ü Good Moisture, Chemical Abrasion Resistance

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Fiber Braiding

CONSTRUCTION DETAILS AND DIMENSIONS

JSS 51037, IS 8130

Voltage Grade : 600/1100V

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

1/26 1/0.40 0.4 0.125 0.6 0.7 0.72 0.8 1 1.1 140 37/34 7/0.16 0.48 0.14 0.68 0.78 0.8 0.88 1.08 1.18 132 3

19/38 19/0.10 0.51 0.149 0.71 0.81 0.83 0.91 1.11 1.21 125 31/24 1/0.51 0.51 0.204 0.71 0.81 0.83 0.91 1.11 1.21 87 47/32 7/0.20 0.61 0.219 0.81 0.91 0.93 1.01 1.21 1.31 82 4

19/36 19/0.13 0.64 0.252 0.84 0.94 0.96 1.04 1.24 1.34 79 41/22 1/0.64 0.64 0.321 0.84 0.94 0.96 1.04 1.24 1.34 55 7.37/30 7/0.25 0.76 0.343 0.96 1.06 1.08 1.16 1.36 1.46 52 7.3

19/34 19/0.16 0.81 0.382 1.01 1.11 1.13 1.21 1.41 1.51 49 7.31/20 1/0.81 0.81 0.515 1.01 1.11 1.13 1.21 1.41 1.51 34 117/28 7/0.32 0.97 0.562 1.17 1.27 1.29 1.37 1.57 1.67 32 11

19/32 19/0.20 1.02 0.596 1.22 1.32 1.34 1.42 1.62 1.72 30 117/26 7/0.40 1.22 0.879 1.54 1.72 1.82 1.92 20 16

19/30 19/0.25 1.27 0.932 1.59 1.77 1.87 1.97 18 1619/29 19/0.29 1.45 1.254 1.77 1.95 2.05 2.25 14 2219/28 19/0.32 1.6 1.528 1.92 2.1 2.2 2.4 12 2619/27 19/0.36 1.83 1.933 2.15 2.33 2.43 2.63 9 3219/26 19/0.40 2 2.387 2.32 2.5 2.6 2.8 7 3519/25 19/0.45 2.31 3.021 2.63 2.81 2.91 3.11 5 4137/28 37/0.32 2.26 2.975 2.58 2.76 2.86 3.06 6 4119/24 19/0.50 2.5 3.73 2.82 3 3.1 3.3 4 4519/22 19/0.65 3.35 6.304 3.67 3.85 3.95 4.15 2 55

S.No.

LK101LK102LK103LK104LK105LK106LK107LK108LK109LK110LK111LK112LK113LK114LK115LK116LK117LK118LK119LK120LK121LK122LK123

Size

SWG

2626262424242222222020201818161514131212111010 37/26 37/0.4 2.82 4.649 3.14 3.32 3.42 3.62 3 50

Max Weight gm/mtr

2.292.552.623.173.463.814.434.815.246.447.117.50

10.3610.9114.5817.3121.3725.7632.0231.5138.7463.4247.58

H

Page 155: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H13

LEAD WIRE

LF-101

FIBER GLASS INSULATED - 400°C

AVAILABLE OPTIONS

SPECIFICATIONS

Conductor : Solid, Multistrand, Copper Material (Bare Copper, TPC, NPC, SPC)

Insulation : Fiber Glass with High Temperature Varnish

Voltage rating : Up to 1.1 KV

Operating Temp. : 400°C

FEATURES

ü Max. Temp. Up to 400°C

ü Excellent Abrasion Resistance

ü Excellent Heat Resistivity

ü Excellent resist to Oil, moist, fluids and chemicals

ü Excellent Di-electric Properties

ü High Temperature & Voltage Rating

ü Excellent Flame Retardant

ü 250 V / 600 V / 1100 V As per Customer Requirement

ü Metal Covering

CONSTRUCTION DETAILS AND DIMENSIONS

IS 8130

Voltage Grade : 600/1100V

S.No.Size

Number of Strands/Dia of each Strand

Dia of Conduc

tor

Cross Sectional Area

ET 250 V E 600 V EE 1000 V Max Res.

OHMS/KM at 20°C

Current

Rating (amps

)OD of insulation

OD of insulation

OD of insulation

SWG AWG (mm) (mm) mm²Min

(mm)Max.(mm)

Min(mm)

Min(mm)

Max.(mm)

Max.(mm)

LF101 26 19/38 19/0.10 0.51 0.14 0.81 1.01 1.07 1.21 1.37 1.41 125 3LF102 24 1/24 1/0.51 0.51 0.20 0.81 1.01 1.07 1.21 1.37 1.41 87 4LF103 24 7/32 7/0.20 0.61 0.21 0.91 1.11 1.17 1.31 1.47 1.51 82 4LF104 24 19/36 19/0.13 0.64 0.25 0.94 1.14 1.20 1.34 1.50 1.54 79 4LF105 22 1/22 1/0.64 0.64 0.32 0.94 1.14 1.20 1.34 1.50 1.54 55 7.3LF106 22 7/30 7/0.25 0.76 0.34 1.06 1.26 1.32 1.46 1.62 1.66 52 7.3LF107 22 19/34 19/0.16 0.81 0.38 1.11 1.31 1.37 1.51 1.67 1.71 49 7.3LF108 20 1/20 1/0.81 0.81 0.51 1.11 1.31 1.37 1.51 1.67 1.71 34 11LF109 20 7/28 7/0.32 0.97 0.56 1.27 1.47 1.53 1.67 1.83 1.87 32 11LF110 20 19/32 19/0.20 1.02 0.59 1.32 1.52 1.58 1.72 1.88 1.92 30 11LF111 18 7/26 7/0.40 1.22 0.87 1.78 2.02 2.08 2.12 20 16LF112 18 19/30 19/0.25 1.27 0.93 1.83 2.07 2.13 2.17 18 16LF113 16 19/29 19/0.29 1.45 1.25 2.01 2.25 2.31 2.45 14 22LF114 15 19/28 19/0.32 1.60 1.52 2.16 2.40 2.46 2.60 12 26LF115 14 19/27 19/0.36 1.83 1.93 2.39 2.63 2.69 2.83 9 32LF116 13 19/26 19/0.40 2.00 2.38 2.56 2.80 2.86 3.00 7 35LF117 12 19/25 19/0.45 2.31 3.02 2.87 3.11 3.17 3.31 5 41LF118 12 37/28 37/0.32 2.26 2.97 2.82 3.06 3.12 3.26 6 41LF119 11 19/24 19/0.50 2.50 3.73 3.06 3.30 3.36 3.50 4 45LF120 10 19/22 19/0.65 3.35 6.30 3.91 4.15 4.21 4.35 2 55LF121 10 37/26 37/0.40 2.82 4.64 3.38 3.62 3.68 3.82 3 50

Max Weight gm/mtr

3.383.874.224.585.205.656.117.318.088.4811.4512.0315.8818.7022.8827.3733.8133.2740.6465.8049.66

H1

Page 156: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

H14

LEAD WIRE ORDERING CODE

ORDERING CODE

(LXX)

PKT0TFETPFMFFTAMP0S0FSK0F0

Type Of Insulation

(XXX)

101102103

---------

123

ConductorSize

(XXX)

BC0TPCNPCSPCPN0

Type Of Conductor

(XX)

REYEBRBLBKGRPUORWHGN

Color Code

Note :

Insulation Type Type of Conductor Color

PK - (PEEK) BC0 - (Bare Copper) RE - (Red)

T0 - (PTFE) TPC - (Tin Plated Copper) YE - (Yellow)

TF - (FEP) NPC - (Nickel Plated Copper) BR - (Brown)

ET - (ETFE) SPC - (Silver Plated Copper) BL - (Blue)

PF - (PFA) PN0 - (Pure Nickel) BK - (Black)

MF - (MFA) GR - (Grey)

FT - (PTFE /Fibre Glass) PU - (Purple)

AM - (Mica / Alumina) OR - (Orange)

P0 - (PVC) WH - (White)

S0 - (Silicon) GN - (Green)

FS - (Silicon / Fibre Glass)

K0 - (Polymide)

F0 - (Fibre Glass)

Example :

AWG 24/7/32 Tin Plated Copper FEP Insulated Black Color Lead Wire.

LTF - 105 - TPC - BKH

Page 157: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

Sleeves I

Page 158: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 159: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

I1

EXTRUDED

SFEP-101

(FEP) INSULATED SLEEVE 200°C

EXTRUDED FEP INSULATED SLEEVE

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant

ü Excellent Dielectric Property

ü Excellent Chemical Resistant

ü Non Stick Property

ü Weather Resistant

ü Flame Retardant

ü Good Thermal Stability

ü Fiber Over Braided.

ü SS Wire Covering

ü Available in Different Color

ü Available with different wall thickness as well as voltage Grade.

(XX)

REYEBRBLBKGRPUORWHGN

Color Code

(SFEPXXX)

101to

114

Conductor Size

ORDERING CODE

Note : RE - (Red), YE - (Yellow), BR - (Brown), BL - (Blue), BK - (Black), GR - (Grey), PU - (Purple), OR - (Orange), WH - (White), GN - (Green)

S.No.Size in(mm)

Inner Dia(mm)

Wall Thickness(mm)

Max. Outer Dia(in mm)

Approx Weight(gm/mtr)

SFEP101 1 1 0.2 1.4 1.8SFEP102 1.2 1.2 0.2 1.6 2.1SFEP103 1.4 1.4 0.25 1.9 3.1SFEP104 1.5 1.5 0.3 2.1 4SFEP105 1.6 1.6 0.3 2.2 4.3SFEP106 1.75 1.75 0.35 2.45 5.3SFEP107 2 2 0.35 2.7 5.9SFEP108 2.5 2.5 0.35 3.2 7.1SFEP109 4 4 0.4 4.8 12.5SFEP110 6 6 0.45 6.9 20.4SFEP111 8 8 0.5 9 30.2SFEP112 10 10 0.55 11.1 42.6SFEP113 12 12 0.6 13.2 53.6SFEP114 16 16 0.65 17.3 78.5

I

Page 160: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

I2

EXTRUDED

SPFA-101

(PFA) INSULATED SLEEVE 260°C

EXTRUDED PFA (PTFE) INSULATED SLEEVE

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant.

ü Excellent Dielectric Property.

ü Excellent Abrasion Resistant

ü Excellent Chemical Resistant.

ü Non Stick Property.

ü Weather Resistant.

ü Flame Retardant.

ü Good Thermal Stability

ü Fiber Over Braided.

ü SS Wire Covering

ü Available in Different Color

ü Available with different wall thickness as well as voltage Grade.

(XX)

REYEBRBLBKGRPUORWHGN

Color Code

(SPFAXXX)

101to

114

Conductor Size

ORDERING CODE

Note : RE - (Red), YE - (Yellow), BR - (Brown), BL - (Blue), BK - (Black), GR - (Grey), PU - (Purple), OR - (Orange), WH - (White), GN - (Green)

S.No.Size in(mm)

Inner Dia(mm)

Wall Thickness(mm)

Max. Outer Dia(in mm)

Approx Weight(gm/mtr)

SPFA101SPFA102SPFA103SPFA104SPFA105SPFA106SPFA107SPFA108SPFA109SPFA110SPFA111SPFA112SPFA113SPFA114

1 1 0.25 1.5 2.31.2 1.2 0.25 1.7 2.71.4 1.4 0.3 2 3.71.5 1.5 0.3 2.1 41.6 1.6 0.35 2.3 4.9

1.75 1.75 0.35 2.45 5.32 2 0.4 2.8 6.8

2.5 2.5 0.4 3.3 8.24 4 0.45 4.9 14.46 6 0.5 7 23.48 8 0.55 9.1 33.2

10 10 0.6 11.2 45.212 12 0.65 13.3 57.416 16 0.7 17.4 82.5

I

Page 161: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

I3

WRAPPED

STEF-101

PTFE INSULATED SLEEVE 260°C

WRAPPED PTFE INSULATED SLEEVE

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 260°C

ü Excellent Heat Resistant..

ü Excellent Chemical Resistant

ü Non Stick Property.

ü Weather Resistant.

ü Good Thermal Stability

ü Fiber Over Braided.

ü SS Wire Covering

ü Available in Different Color

ü Available with different wall thickness as well as voltage Grade.

(XX)

REYEBRBLBKGRPUORWHGN

Color Code

(STEFXXX)

101to

114

Conductor Size

ORDERING CODE

Note : RE - (Red), YE - (Yellow), BR - (Brown), BL - (Blue), BK - (Black), GR - (Grey), PU - (Purple), OR - (Orange), WH - (White), GN - (Green)

S.No.Size in(mm)

Inner Dia(mm)

Wall Thickness(mm)

Max. Outer Dia(in mm)

Approx Weight(gm/mtr)

STEF101 1 1 0.2 1.4 1.8STEF102 1.2 1.2 0.2 1.6 2.1STEF103 1.4 1.4 0.25 1.9 3.1STEF104 1.5 1.5 0.3 2.1 4STEF105 1.6 1.6 0.3 2.2 4.3STEF106 1.75 1.75 0.35 2.45 5.3STEF107 2 2 0.35 2.7 5.9STEF108 2.5 2.5 0.35 3.2 7.1STEF109 4 4 0.4 4.8 12.5STEF110 6 6 0.45 6.9 20.4STEF111 8 8 0.5 9 30.2STEF112 10 10 0.55 11.1 42.6STEF113 12 12 0.6 13.2 53.6STEF114 16 16 0.65 17.3 78.5

I

Page 162: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

I4

EXTRUDED

SPVC-101

PVC INSULATED SLEEVE 90°C

EXTRUDED PVC INSULATED SLEEVE

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 90°C

ü Good Thermal Stability.

ü Good Tensile Strength & Elongation.

ü Good Flexibility.

ü Excellent Abrasion Resistance.

ü Resist against many solvent, oils, and concentrated acids.

ü Economical

ü Outstanding Electrical Properties

ü SS Wire Covering

ü Available in Different Color

ü Available with different wall thickness as well as voltage Grade.

ü Available with flame retardant & Low smoke properties.

ü Available with Heat Resisting Properties.

(XX)

REYEBRBLBKGRPUORWHGN

Color Code

(SPVCXXX)

101to

111

Conductor Size

ORDERING CODE

Note : RE - (Red), YE - (Yellow), BR - (Brown), BL - (Blue), BK - (Black), GR - (Grey), PU - (Purple), OR - (Orange), WH - (White), GN - (Green)

S.No.Size in(mm)

Inner Dia(mm)

Wall Thickness(mm)

Max. Outer Dia(in mm)

Approx Weight(gm/mtr)

SPVC101 1.5 1.5 0.6 2.7 6.3SPVC102 2 12 0.6 3.2 7.6SPVC103 2.5 2.5 0.8 4.1 12.9SPVC104 3 3 0.8 4.6 15.0SPVC105 4 4 1 6 25.2SPVC106 6 6 1 8 33.9SPVC107 8 8 1.2 10.4 56.2SPVC108 10 10 1.4 12.8 80.3SPVC109 12 12 1.6 15.2 108.3SPVC110 14 14 1.6 17.2 124.5SPVC111 16 16 1.8 19.6 158.5

I

Page 163: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

I5

EXTRUDED

SSIL-101

SILICON INSULATED SLEEVE 200°C

EXTRUDED SILICON INSULATED SLEEVE

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 200°C

ü Excellent Heat Resistant.

ü Excellent Flexibility.

ü Excellent Abrasion Resistance.

ü Good Strength.

ü Resist against many solvent, oils, and concentrated acids.

ü Outstanding Electrical Properties

ü Fiber Over Braided.

ü SS Wire Covering

ü Available in Different Color

ü Available with different wall thickness as well as voltage Grade.

(XX)

REYEBRBLBKGRPUORWHGN

Color Code

(SSILXXX)

101to

111

Conductor Size

ORDERING CODE

Note : RE - (Red), YE - (Yellow), BR - (Brown), BL - (Blue), BK - (Black), GR - (Grey), PU - (Purple), OR - (Orange), WH - (White), GN - (Green)

S.No.Size in(mm)

Inner Dia(mm)

Wall Thickness(mm)

Max. Outer Dia(in mm)

Approx Weight(gm/mtr)

SSIL101 1.5 1.5 0.6 2.7 6.2SSIL102 2 5 0.6 3.2 7.5SSIL103 2.5 2.5 0.8 4.1 12.8SSIL104 3 3 0.8 4.6 14.8SSIL105 4 4 1 6 24.8SSIL106 6 6 1 8 33.6SSIL107 8 8 1.2 10.4 55SSIL108 10 10 1.4 12.8 78.2SSIL109 12 12 1.6 15.2 105.3SSIL110 14 14 1.6 17.2 120.5SSIL111 16 16 1.8 19.6 155

I

Page 164: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

I6

BRAIDED

SFIB-101

FIBER GLASS INSULATED SLEEVE 400°C

BRAIDED FIBRE GLASS INSULATED SLEEVE

AVAILABLE OPTIONSFEATURES

ü Max. Temp. Up to 400°C

ü Excellent Heat Resistant.

ü Excellent Flexibility.

ü Silicon Insulated Varnish at outer.

ü Good Strength.

ü Resist against many solvent, oils, and concentrated acids.

ü Outstanding Electrical Properties

ü Available in White & Black Color

ü Available with different wall thickness as well as voltage Grade.

(XX)

BKWH

Color Code

(SFIBXXX)

101to

107

Conductor Size

ORDERING CODE

Note : BK - (Black), WH - (White)

S.No.Size in(mm)

Inner Dia(mm)

Wall Thickness(mm)

Max. Outer Dia(in mm)

Approx Weight(gm/mtr)

SFIB101 1.5 1.5 0.20 1.90 3.00SFIB102 2.0 5 0.30 2.60 5.00SFIB103 3.0 3.0 0.35 3.70 7.50SFIB104 6.0 6.0 0.40 6.80 15.00SFIB105 12.0 12.0 0.60 13.20 40.00SFIB106 15.0 15.0 0.60 16.20 48.00SFIB107 16.0 16.0 0.65 17.30 52.00

I

Page 165: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 166: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 167: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J1

Mineral Insulated CablesGeneral InformationOne or more conductors (cores) are embedded in MgO and pressed into a metal tube made of oxidation and corrosion resistant material. The entire combination is then processed using suitable forming steps to obtain the final dimensions.

In other words Mineral Insulated Cable, comprising a metal sheath in which the conductors are embedded in highly compressed magnesium oxide insulation.

Mineral insulated cables are designed for high-temperature applications and used wherever in a particularly strict requirements with regard to mechanical, chemical and electrical stability.

On account of their good flexibility, the use of mineral insulated cables are preferred in areas where mounting is difficult and where a high degree of flexibility is required. The minimum bending radius is 3 times the outer diameter of the mineral insulated cable.

Innovations in technology and manufacturing have made it possible for these cables to be used increasingly frequently as a material in the manufacture of standardized thermocouples and RTDs, in particular in industrial measuring and control technology and in automotive sensor technology.

Mineral Insulated Cables

(1) Mineral Insulated Thermocouple Cable.

(2) Mineral Insulated RTD Cable.

(3) Mineral Insulated Heater Cable.

(4) Mineral Insulated Power Cable.

Raw Material for Mineral Insulated Cable

i. Standard Sheath Material:i

Metal Sheath

Insulating Sheath (Magnesium Oxide)Conductors

SheathMaterial

Maximum Operating

temperature Material Properties Applications

SS304AISI 3041.4301

800°C Resistance to intercrystalline corrosion. Good resistance to organic acids at moderate temperatures, saline solutions, such as sulphates, sulphides and sulphites, and alkaline solutions at moderate temperatures.Good welding properties.

Used in chemical, petrochemical and fertilizer industries, and as equipment in dairy, food processing, pharmaceutical industries, in hospitals, households as kitchenware, cryogenic vessels and as heat exchanger in air conditioning refrigeration, for machinery in paper, pulp and textile beverage sectors.

SS316 AISI 3161.4401

800°C An austenitic stainless steel with 2.0 to 3% Mo. which improves corrosion resistance and imparts hot strength characteristics. Used for applications requiring resistance to pitting corrosion. and in halogen atmospheres. Good welding properties

Architectural trims, marine exteriors, chemical processing equipment, food processing equipment, petroleum refining equipment, pharmaceutical equipment, photographic equipment, pulp and paper processing equipment, textile finishing equipment, etc.

SS321AISI 3211.4541

800 °C Good resistance to intercrystalline corrosion, also after welding. Good resistance to heavy oil products, steam and exhaust gases. Good oxidation resistance. Can be used continuously up to approximately 800°C. Good welding properties in all standard welding processes without the need for welding retreatment. Good ductility.

Nuclear power and reactor construction, chemical apparatus engineer ing, annealing furnaces, heat exchangers, paper and textile industry, petrochemical and crude oil industry, grease and soap industry, food processing industry. used for aircraft exhaust stacks and manifolds, pressure vessels, large mufflers for diesel engines, carburetors, expansions belows, stack liners, fire walls etc.

SS446AISI 4461.4749

1150 °C Extremely good resistance to reducing, sulphurous atmospheres. Very good resistance to oxidation and air. Good resistance to corrosion caused by incinerator slag and copper, lead and tin smelts. Good welding properties in arc welding and WIG welding. Preheating to 200 - 400 °C is recommended. Retreatment is not necessary.

Petrochemical industry, metallurgy, power technology, recuperators, heat treatment kilns, vortex firing installations, waste incinerators.

J

Page 168: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J2

SS310/310SAISI 310/310S

1.4845

1100 °C Grade 310S is a low carbon version of grade 310. 310S is less prone to embrittlement and sensitization in service. Good resistance to oxidation and sulphidisation. Due to the high content of chromium, the material is resistant to oxidizing hydrous solutions and has good resistance to chlorine-induced tension crack corrosion. Good resistance in cyanide smelts and neutral salt melts at high temperatures. Not susceptible to green mould. Good welding properties. It is recommended to weld with low heat impact. Apply solution annealing after welding to avoid the danger of intercrystalline corrosion.

Boilers and blast furnaces, cement and brick kilns, glass production, crude oil and petrochemical industries, furnace construction and power stations. Kilns, Heat Exchangers, Radiant Tubes, Muffles, retorts, annealing covers, Tube hangers for petroleum refining and steam b o i l e r s , C o a l g a s i f i e r i n t e r n a l components, Saggers, Furnace parts, conveyor belts, rollers, oven linings, fans, Food processing equipment, Cryogenic structures.

Inconel 6002.4816

1100 °C Good general resistance to corrosion, resistant to tension crack corrosion. Excellent resistance to oxidation. Not recommended with gases containing CO2 and sulphur above 550°C and sodium above 750°C. In air, resistant up to 1100°C. Good welding properties for all types of welding processes. Excellent ductility even after long-term use.

P W R , n u c l e a r p o w e r, f u r n a c e construction, plastics industry, heat treatment, paper and food processing industries, boilers, aircraft engines.

Inconel 8001.4876

1100 °Cin air

This material provides superior thermal stability due to the addition of titanium and aluminum. Suitable for applications requiring maximum stability under load in addition to scaling resistance. Excellent res is tance to carbur izat ion and nitrogenisation. The material has good welding properties in arc and WIG welding processes. Heat treatment is not necessary after welding.

Power s ta t i ons , c rude o i l and petrochemical industries, furnace construction.

Nimonic 752.4951

1100 °C Excellent high-temperature stability and resistance to oxidation and carburization. Due to the combination of nickel and chromium, the material has very good resistance to hot, gaseous media. Resistance to thermal fatigue and thermal shock. Good welding properties for all types of welding processes. Excellent ductility even after long-term use.

Space travel, aircraft construction, nuclear reactors, mechanical engineering, metal working, thermal materials processing.

Pt 10 % Rh 1300 °C High-temperature resistance up to 1300°C under oxidizing conditions. High heat resistance up to 1200°C in the presence of oxygen, sulphur and silicon. Especially resistant to halogens, ethanolic acids, NaHCl solutions etc. Can become brittle through the absorption of silicon from armoring ceramics. Sulphur eutectics possible at temperatures over 1000°C. Sensitive to phosphorus.

Glass, electrochemical and catalytic t e c h n o l o g y, c h e m i c a l i n d u s t r y, laboratories, melting and annealing furnaces and other furnaces, final storage of nuclear power products.

Other sheathed material are available on request

J

Page 169: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J3

ii. Insulation (Magnesium Oxide)

Tempsens supplies MgO as the standard insulator with standard purity of ≥ 97% as well as MgO with a high purity of ≥ 99.4% as

per specification ASTM E 1652

PURITYHIGH PURITY

(≥ 99.4 % PURE)STANDARD PURITY

( ≥ 97 % PURE)

COMPOSITIONCONCENTRATION

(MASS) %CONCENTRATION

(MASS) %

MgO 99.4 % (min) 97 % (min)

CaO 0.35 % (max) 0.80 % (max)

Al2O3 0.15 % (max) 1.00 % (max)

Fe2O3 0.04 % (max) 0.08 % (max)

SiO2 0.13 % (max) 1.20 % (max)

C 0.02 % (max) 0.02 % (max)

S 0.005 % (max) 0.005 % (max)

B 0.0035 % (max) 0.0025 % (max)

Cd 0.001 % (max) 0.001 % (max)

B+Cd 0.004 % (max) 0.003 % (max)

Fe - 0.02 % (max)

Values obtained from specification astm e 1652

Insulation ResistanceThe insulation resistance depends on the purity of the insulation ceramics used as well as the manufacturing process and the humidity content of the insulation. The cables are supplied fully dried with ends that are hermetically sealed.

Nominal Sheath Outside Diameter Applied Voltage (Minimum), V, DC Insulation Resistance (Minimum), MΏ

Less than 0.80 mm 50 V 1000 MΏ

0.80 mm to 1.45 mm 50 V 5000 MΏ

Greater than 1.45 mm 500 V 10000 MΏ

Values Obtained from Specification ASTM E-608

Testing of Mineral Insulated Cable

S. No. Name Of Test Descriptions Standard Test

a) Sheath Outer Diameter ASTM E585/E585M-09 Routine Test

b) Sheath Wall Thickness ASTM E585/E585M-09 Routine Test

c) Insulation thickness ASTM E585/E585M-09 Type Test

d) Conductor Diameter ASTM E585/E585M-09 Routine Test

Dimensions test1

a) At ambient Temperature ASTM E 839-03 Routine Test

b) At elevated Temperature ASTM E 839-03 Type TestInsulation Resistance Test2

a) By Tension test ASTM E 839-03 Type Test

b) By Calculation ASTM E 839-03 Type Test

Insulation Compaction Density

3

By Measuring ASTM E 839-03 Routine TestContinuity Test4

By Measuring ASTM E 839-03 Routine TestLoop Resistance Test5

Insulation Resistance at Room Temperature

J

Page 170: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J4

S. No. Name Of Test Descriptions Standard Test

a) Water test ASTM E 839-03 Routine Test

b) Helium leak test ASTM E 839-03 Routine Test

c) Dye Penetrate Test ASTM E 839-03 Type Test

d) Bend TestASTM E 839-03/ IEC

60702-1/IEEE 515Type Test

e) Tension Test ASTM E 839-03 Type Test

6 Sheath Integrity Test

As per standard Temperature

ANSI MC 96.1IEC 584-2

Routine Test for MI Thermocouple cable

Calibration Test7

At 325°C for 5 Cycle minimum ASTM E 839-03 Type TestThermal Cycle Test8

At 750°C IEC 60702 Part 1Type Test for MI Power

CableFire Resistance Test9

At 750°C According to Cable ODType Test for MI Power

CableFlattening Test10

All tests perform in house and as per standard.

Mineral Insulated Thermocouple Cable:Mineral insulated thermocouple cables have inner conductors of Thermocouple base material as per standard ASTM E 585/585M and ASTM E 839.

Number of PairSheath

Diameter (mm)

Nominal Wall

Thickness (mm)

Element Diameter

(mm)

Insulation Thickness

(mm)

Insulation Resistance

(MΏ)

Sheath Material

Conductor Type

InsulationCalibration Accuracy

1.50 ≥ 0.15 ≥ 0.23 ≥ 0.11

2.00 ≥ 0.20 ≥ 0.30 ≥ 0.14

2.50 ≥ 0.25 ≥ 0.38 ≥ 0.18

3.00 ≥ 0.30 ≥ 0.45 ≥ 0.21

4.50 ≥ 0.45 ≥ 0.68 ≥ 0.32

6.00 ≥ 0.60 ≥ 0.90 ≥ 0.42

6.40 ≥ 0.64 ≥ 0.96 ≥ 0.45

8.00 ≥ 0.80 ≥ 1.20 ≥ 0.56

9.50 ≥ 0.95 ≥ 1.43 ≥ 0.67

10.00 ≥ 1.00 ≥ 1.50 ≥ 0.70

12.70 ≥ 1.27 ≥ 1.91 ≥ 0.89

Simplex

≥ 100 MΏ

SS316LSS321SS310SS446SS304

Inconel 600Inconel 601and others

K TypeJ TypeE TypeN TypeR TypeS Type

MgO (Standard Purity ≥

97%)

MgO (High Purity ≥99.4%)

Class 1/Class 2 Accuracy

as per IEC 584-2/ANSI

MC 96.1/ASTM

E 230

1.50 ≥ 0.15 ≥ 0.18 ≥ 0.08

2.00 ≥ 0.20 ≥ 0.24 ≥ 0.11

2.50 ≥ 0.25 ≥ 0.30 ≥ 0.14

3.00 ≥ 0.30 ≥ 0.36 ≥ 0.17

4.50 ≥ 0.45 ≥ 0.54 ≥ 0.25

6.00 ≥ 0.60 ≥ 0.72 ≥ 0.33

6.40 ≥ 0.64 ≥ 0.77 ≥ 0.35

8.00 ≥ 0.80 ≥ 0.96 ≥ 0.44

9.50 ≥ 0.95 ≥ 1.14 ≥ 0.52

10.00 ≥ 1.00 ≥ 1.20 ≥ 0.55

12.70 ≥ 1.27 ≥ 1.52 ≥ 0.70

Duplex

≥ 100 MΏ

SS316LSS321SS310SS446SS304

Inconel 600Inconel 601and others

K TypeJ TypeE TypeN TypeR TypeS Type

MgO (Standard Purity ≥

97%)

MgO (High Purity ≥99.4%)

Class 1/Class 2 Accuracy

as per IEC 584-2/ANSI

MC 96.1/ASTM

E 230

3.00 ≥ 0.30 ≥ 0.27 ≥ 0.12

4.50 ≥ 0.45 ≥ 0.41 ≥ 0.18

6.00 ≥ 0.60 ≥ 0.54 ≥ 0.24

6.40 ≥ 0.64 ≥ 0.58 ≥ 0.26

8.00 ≥ 0.80 ≥ 0.72 ≥ 0.32

9.50 ≥ 0.95 ≥ 0.86 ≥ 0.38

10.00 ≥ 1.00 ≥ 0.90 ≥ 0.40

12.70 ≥ 1.27 ≥ 1.14 ≥ 0.51

Triplex

SS316LSS321SS310SS446SS304

Inconel 600Inconel 601and others

K TypeJ TypeE TypeN TypeR TypeS Type

MgO (Standard Purity ≥

97%)

MgO (High Purity ≥99.4%)

Class 1/Class 2 Accuracy

as per IEC 584-2/ANSI

MC 96.1/ASTM

E 230

≥ 100 MΏ

J

Page 171: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J5

Example60KK316 - 6.0 mm OD, SS316L sheath, K Type Duplex Class 1 Accuracy with High purity insulation.Ÿ Note : Class 1 Accuracy, High Purity insulation supplied unless specified.

How To Order - MI Thermocouple Cable

1.52.02.23.04.56.08.09.5

10.812.7

OD (MM)

K - SimplexKK - DuplexKKK - TriplexJ - SimplexJJ - DuplexJJJ - TriplexE -SimplexEE - DuplexEEE - TriplexN - SimplexNN - DuplexNNN - TriplexT - SimplexTT - DuplexTTT - Triplex

TYPE

STANDARD (≥96% PURE )

HIGH PURITY(≥99.4% PURE )

MGO GRADE

IEC CLASS 1IEC CLASS 2

ACCURACYSHEATH

304 – SS304L310 – Ss310

316 – SS316L600 – INCONEL 600800 – INCONEL 800

Others

Note:- Diagonal Element Supplied Unless Specified

Standard Deviation of Mineral Insulated Thermocouple Cable as per IEC 584-2

Type Temperature Range Tolerance for Class 1 Accuracy Tolerance for Class 2 Accuracy

K/N -40°C to +1100°C +/- 1.5°C or +/-0.004(t) +/- 2.5°C or +/-0.0075(t)

J -40°C to +750°C +/- 1.5°C or +/-0.004(t) +/- 2.5°C or +/-0.0075(t)

T -40°C to +350°C +/- 0.5°C or +/-0.004(t) +/- 1.0°C or +/-0.0075(t)

E -40°C to +800°C +/- 1.5°C or +/-0.004(t) +/- 2.5°C or +/-0.0075(t)

R/S 0°C to +1600°C +/-1°C or +/-[1+0.003(t-1100)] +/- 1.5°C or +/-0.0025(t)

Mineral Insulated Thermocouple Cables with Precious Thermocouple:`Precious metal thermocouples are exceptionally suited for high-temperature applications under oxidizing conditions. They are used in chemical plants when absolute resistance to all kinds of acids is required.

Max.Operating Temperature

Resistance of Precious Metal Mineral Insulated Thermocouples in different Atmosphere

Sheath Material

Thermocouple Oxygen Nitrogen Hydrogen Carbon Chlorine Sulphur

1100°CS Type Good Good Good Good Good Conditional

1100°CR Type Good Good Good Good Good Conditional

1100°CB Type Good Good Good Good Good Conditional

Inconel 600 2.4816

1300°CS Type Good Good Conditional Conditional Conditional Conditional

1300°CR Type Good Good Conditional Conditional Conditional Conditional

1300°CB Type Good Good Conditional Conditional Conditional Conditional

pt10%Rh

1.52.02.23.04.56.08.09.5

10.812.7

OD (MM)

R - SimplexRR - DuplexRRR - TriplexS - SimplexSS - DuplexSSS - TriplexB -SimplexBB - DuplexBBB - Triplex

TYPE

STANDARD (≥96% PURE )

HIGH PURITY(≥99.4% PURE )

MGO GRADE

IEC CLASS 1IEC CLASS 2

ACCURACYSHEATH

304 – SS304L310 – SS310

316 – SS316L600 – INCONEL 600800 – INCONEL 800

Others

Note:- Diagonal Element Supplied Unless Specified

How To Order - Precious Thermocouple Cable

Example 60R316 - 6.0 mm OD, SS316L Sheath, R Type Simplex Class 1 Accuracy with High purity insulation.

J

Page 172: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J6

Mineral Insulated Compensating Cable Mineral insulated compensating Cables have inner conductors of R/S Type (Cu- CuNi) and B Type (Cu-Cu) Compensating conductor with copper sheath.

ConductorNo. of Pair

Sheath Material Operating Temperature Testing

R/S Type Compensating Wire

(Cu-CuNi)200°C

(0.645 +/- 0.057) mV as per ANSI MC 96.1

R/S Type Compensating Wire

(Cu-CuNi)200°C

(0.645 +/- 0.057) mV as per ANSI MC 96.1

1

2Copper Sheath

Mineral Insulated Heater Cable

Tempsens Mineral Insulated Heating Cable is an electrical metal sheath heating cable with high economic efficiency (specific heating capacity up to 300 W/m). It is the most rugged and durable type of heating cable. Mineral Insulated Heating Cable is applicable for operation in high temperatures and explosion-proof areas. It can have a very high watt output and is used for process heating applications at temperatures where plastics insulated heating cables are not suitable. When properly installed, it has a very high lifetime.Mineral Insulated Heaters are applicable in the Machinery, power generating industry, chemical and petrochemical industry as well as research and development.

How To Order - MI Compensating CableHow To Order - MI Compensating Cable

Example60 S SC MI: 6.0 mm OD, S type Compensating Conductor, Simplex, and Copper Sheath.

How To Order - MI Heater CableHow To Order - MI Heater Cable

Example48-2NiCr316 Heater MI– 4.8 mm OD, SS316L sheath, 2 Core, NiCr Alloy conductor with High purity insulation.Note :Ÿ High Purity supplied unless specified

4.5 MM6.0 MM8.0 MM

OD (MM)

R - SimplexRR - DuplexRRR - TriplexS - SimplexSS - DuplexSSS - TriplexB -SimplexBB - DuplexBBB - Triplex

TYPE

STANDARD(≥ 96% PURE)

HIGH PURITY(≥ 99.4% PURE)

MGO GRADE

ANSI MC 96.1

ACCURACYSHEATH

SC- Copper Sheath

Note:- Diagonal element supplied unless specified

3.2 MM3.6 MM4.1 MM4.5 MM5.0 MM5.6 MM6.5 MM9.0 MM

OD (MM)

12

NO. OF CONDUCTOR

304 – SS304L310 – SS310

316 – SS316L600 – INCONEL 600800 – INCONEL 800

SHEATH

STANDARD (≥ 96% PURE)

HIGH PURITY (≥ 99.4% PURE)

MGO GRADECONDUCTOR MATERIAL

NiCr – Nickel Chromium Alloy

CuNi – Copper Nickel Alloy

Sheath Material Operating Temperature up to

Inconel 600 (2.4816) and SS316L (1.4404)

800°C

SS321/AISI 321 (1.4541) 500°C

Heating Element

NiCr Alloy

CuNi Alloy

J

Page 173: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J7

Technical Data

Conductors NiCr Alloy, applicable for temperature up to 800°C

Outer Diameter (mm)

Resistance at 20°C (Ώ/m)

Conductor Diameter (mm)

Wall Thickness(mm)Maximum Voltage

Rating

3.2 10 0.38 ≥ 0.32

3.2 6.3 0.48 ≥0.32

3.2 4 0.61 ≥0.32

3.6 2.5 0.77 ≥ 0.36

3.8 1.6 0.96 ≥ 0.38

4.1 1 1.21 ≥ 0.41

4.5 0.63 1.52 ≥ 0.45

5 0.4 1.91 ≥ 0.50

5.6 0.25 2.42 ≥ 0.56

6.5 0.16 3.03 ≥ 0.65

800 V

Conductors CuNi, applicable for temperature up to 500°C

6.5 0.16 3.03 ≥ 0.65

6.5 0.16 3.03 ≥ 0.65

6.5 0.16 3.03 ≥ 0.65

6.5 0.16 3.03 ≥ 0.65

6.5 0.16 3.03 ≥ 0.65

6.5 0.16 3.03 ≥ 0.65

up to 300V /500V

Tolerance for the resistance per Mtr: ± 10%Tolerance for the outer diameter: according to DIN EN 61515Example : 45-NiCr316 Heater MI Cable : 4.5 mm OD, 1 Core, NiCr Alloy Conductor, SS316L Sheath

Mineral Insulated RTD CableMineral insulated cables for RTDs have inner conductors of copper, copper-nickel alloys, nickel, nickel-chromium or nickel-plated copper.

Sheath Diameter

(mm)

Number of Core

Nominal Wall Thickness

(mm)

Element Diameter

(mm)

Insulation Resistance

(MΏ)

Sheath Material

Conductor Type

Insulation

2.00 ≥ 0.20 ≥ 0.30

2.50 ≥ 0.25 ≥ 0.38

3.00 ≥ 0.30 ≥ 0.45

4.50 ≥ 0.45 ≥ 0.68

6.00 ≥ 0.60 ≥ 0.90

6.40 ≥ 0.64 ≥ 0.96

8.00 ≥ 0.80 ≥ 1.20

9.50 ≥ 0.95 ≥ 1.43

10.00 ≥ 1.00 ≥ 1.50

≥ 100 MΏ

SS316LSS321SS304

Inconel 600and others

MgO (Standard

Purity ≥97%)

MgO (High Purity ≥99.4%)

CopperNickel

Nickel-Copper Alloy

and others

2 Core & 3 Core

2.00 ≥ 0.20 ≥ 0.24

2.50 ≥ 0.25 ≥ 0.30

3.00 ≥ 0.30 ≥ 0.36

4.50 ≥ 0.45 ≥ 0.54

6.00 ≥ 0.60 ≥ 0.72

6.40 ≥ 0.64 ≥ 0.77

8.00 ≥ 0.80 ≥ 0.96

9.50 ≥ 0.95 ≥ 1.14

10.00 ≥ 1.00 ≥ 1.20

≥ 100 MΏ

SS316LSS321SS304

Inconel 600and others

MgO (Standard

Purity ≥97%)

MgO (High Purity ≥99.4%)

CopperNickel

Nickel-Copper Alloy

and others

4 Core

3.00 ≥ 0.30 ≥ 0.30

4.50 ≥ 0.45 ≥ 0.45

6.00 ≥ 0.60 ≥ 0.60

6.40 ≥ 0.64 ≥ 0.64

8.00 ≥ 0.80 ≥ 0.80

9.50 ≥ 0.95 ≥ 0.95

10.00 ≥ 1.00 ≥ 1.00

≥ 100 MΏ

SS316LSS321SS304

Inconel 600and others

6 Core

6.00 ≥ 0.60 ≥ 0.60

6.40 ≥ 0.64 ≥ 0.64

8.00 ≥ 0.80 ≥ 0.80

9.50 ≥ 0.95 ≥ 0.95

10.00 ≥ 1.00 ≥ 1.00

≥ 100 MΏ

SS316LSS321SS304

Inconel 600and others

MgO (Standard

Purity ≥97%)

MgO (High Purity ≥99.4%)

MgO (Standard Purity ≥97%)

MgO (High Purity ≥99.4%)

CopperNickel

Nickel-Copper Alloy

and others

CopperNickel

Nickel-Copper Alloy

and others

8 Core

J

Page 174: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

J8

Ordering Example80-4Cu316 RTD MI Cable : 8.0 mm OD, 4 Cores, Copper Conductor, SS316L Sheath60-6NiCu600 RTD MI Cable : 8.0 mm OD, 4 Cores, Nickel-Copper Alloy Conductor (Constantan), Inconel 600 Sheath

Mineral Insulated Power Cable

Mineral Insulated Copper cable belongs to electric cable class.Outer Sheath : Copper Sheath with melting point of 1083°CInsulation : Magnesium oxide insulator, hardly compressed, with melting point of 2800°C.Conductor: Annealed conductor of 99.9% of purity electrolytic copper wire, with melting point of 1083°C

Applicable Standard : IEC/EN 60702 Part 1Ÿ Maximum Continuous Temperature of Conductor is 250°C.Ÿ Heavy Duty Grade Cable : Voltage Grade 750V

How to Order - MI Power Cable

How To Order - MI RTD CableHow To Order - MI RTD Cable

Example 48-2NiCr316 Heater MI– 4.8 mm OD, SS316L sheath, 2 Core, NiCr Alloy conductor with High purity insulation.Note :Ÿ High Purity supplied unless specified

Example2 C 2.5 – 8.70 mm OD, Copper sheath, 2 Core, Copper conductor with size of 2.5 sqmm (1.78 mm).

1.52.02.23.04.54.86.08.09.5

OD (MM)

23468

NO. OF CONDUCTOR

304 – SS304L310 – Ss310

316 – SS316L

600–INCONEL 600

800–INCONEL 800

SHEATH

STANDARD(≥ 96% PURE )

HIGH PURITY(≥ 99.4% PURE )

MGO GRADECONDUCTOR MATERIAL

Ni – NickelCu – Copper

NiCu – Constantan304 – Stainless

Type of CableNo. of Core X

Core Size (MM2)

Nominal Outer Copper

Sheath Diameter

(MM)

Mean Copper Sheath

thickness (MM)

Nominal Core diameter

(MM)

Maximum Core

resistance (Ώ/Km)

Nominal Insulation thickness

(MM)

Maximum Resistance of

Copper Sheath (Ώ/Km)

Suitable for (450/750 v); Single Core

1 C 1.5 1 X 1.5 4.9 0.41 1.38 12.1 1.3 4.13

1 C 2.5 1 X 2.5 5.3 0.42 1.78 7.41 1.3 3.71

1 C 4 1 X 4 5.9 0.45 2.26 4.61 1.3 3.09

1 C 6 1 X 6 6.4 0.48 2.76 3.08 1.3 2.67

Suitable for (450/750 v); Multi Core

2 C 1.5 2 X 1.5 7.9 0.54 1.38 12.1 1.3 1.9

2 C 2.5 2 X 2.5 8.7 0.57 1.78 7.41 1.3 1.63

2 C 4 2 X 4 9.8 0.61 2.26 4.61 1.3 1.35

2 C 6 2 X 6 10.9 0.65 2.76 3.08 1.3 1.13

3 C 4 3 X 4 10.4 0.63 2.26 4.61 1.3 1.23

3 C 2.5 3 X 2.5 9.3 0.59 1.78 7.41 1.3 1.47

3 C 1.5 3 X 1.5 8.3 0.56 1.38 12.1 1.3 1.75J

Page 175: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

Technical References K

Page 176: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 177: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

K1

Glossary

°C µV °C µV °C °C °CµV µV µV

10 0,397 270 10,971 530 790 105021924 32865 43211

20 0,798 280 11,382 540 800 106022350 33275 43595

30 1,203 290 11,795 550 810 107022776 33685 43978

40 1,612 300 12,209 560 820 108023203 34093 44359

50 1,023 310 12,624 570 830 109023629 34501 44740

60 2,436 320 13,040 580 840 110024055 34908 45119

70 2,851 330 13,457 590 850 111024480 35313 45495

80 3,267 340 13,874 600 860 112024905 35718 45873

90 3,682 350 14,293 610 870 113025330 36121 46249

100 4,096 360 14,713 620 880 114025755 36524 46623

110 4,509 370 15,133 630 890 115026179 36925 46995

120 4,920 380 15,554 640 900 116026602 37326 47367

130 5,328 390 15,975 650 910 117027025 37725 47737

140 5,735 400 16,397 660 920 118027447 38124 48105

150 6,138 410 16,820 670 930 119027869 38522 48473

160 6,540 420 17,243 680 940 120028289 38918 48838

170 6,941 430 17,667 690 950 121028710 39314 49202

180 7,340 440 18,091 700 960 122029129 39708 49565

190 7,739 450 18,516 710 970 123029548 40101 49926

200 8,138 460 18,941 720 980 124029965 40494 50286

210 8,539 470 19,366 730 990 125030382 40885 50644

220 8,940 480 19,792 740 1000 126030798 41276 51000

230 9,343 490 20,218 750 1010 127031213 41665 51355

240 9,747 500 20,644 760 1020 128031628 42053 51708

250 10,153 510 21,071 770 1030 129032041 42440 52060

260 10,561 520 21,497 780 1040 130032453 42826 52410

Temperature-emf for Type K Thermocouple

°C µV °C µV °C °C °CµV µV µV

10 0507 210 11334 410 610 81022400 33689 46141

20 1019 220 11889 420 620 82022952 34279 46786

30 1537 230 12445 430 630 83023504 34873 47431

40 2059 240 13000 440 640 84024057 35470 48715

50 2585 250 13555 450 650 85024610 36071 48715

60 3116 260 14110 460 660 86025164 36675 -

70 3650 270 14665 470 670 87025720 37284 -

80 4187 280 15219 480 680 88026276 37896 -

90 4726 290 15773 490 690 89026834 38512 -

100 5269 300 16327 500 700 90027393 39132 -

110 5814 310 16881 510 710 91027953 39755 -

120 6360 320 17434 520 720 92028516 40382 -

130 6909 330 17986 530 730 93029080 41012 -

140 7459 340 18538 540 740 94029647 41645 -

150 8010 350 19090 550 750 95030216 42281 -

160 8562 360 19642 560 760 96030788 42919 -

170 9115 370 20194 570 770 97031362 43560 -

180 9669 380 20745 580 780 98031939 44203 -

190 10224 390 21297 590 790 99032519 44848 -

200 10779 400 21848 600 800 100033102 45494 -

Temperature-emf for Type J Thermocouple

K

Page 178: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

K2

Temperature-emf for Type N Thermocouple

°C µV °C µV °C °C °CµV µV µV

50 0507 310 11334 570 830 109022400 33689 39706

60 1019 320 11889 580 840 110022952 34279 40087

70 1537 330 12445 590 850 111023504 34873 40466

80 2059 340 13000 600 860 112024057 35470 40845

90 2585 350 13555 610 870 113024610 36071 41223

100 3116 360 14110 620 880 114025164 36675 41600

110 3650 370 14665 630 890 115025720 37284 41976

120 4187 380 15219 640 900 116026276 37896 42352

130 4726 390 15773 650 910 117026834 38512 42727

140 5269 400 16327 660 920 118027393 39132 43101

150 5814 410 16881 670 930 119027953 39755 43474

160 6360 420 17434 680 940 120028516 40382 43846

170 6909 430 17986 690 950 121029080 41012 44218

180 7459 440 18538 700 960 122029647 41645 44588

190 8010 450 19090 710 970 123030216 42281 44958

200 8562 460 19642 720 980 124030788 42919 45326

210 9115 470 20194 730 990 125031362 43560 45694

220 9669 480 20745 740 1000 126031939 44203 46060

230 10224 490 21297 750 1010 127032519 44848 46425

240 10779 500 21848 760 1020 128033102 45494 46789

300 8010 560 19090 820 1080 134030216 42281 -

290 8562 550 19642 810 1070 133030788 42919 -

280 9115 540 20194 800 1060 132031362 43560 -

270 9669 530 20745 790 1050 131031939 44203 -

260 10224 520 21297 780 1040 130032519 44848 47513

250 10779 510 21848 770 1030 129033102 45494 47152

Temperature-emf for Type R Thermocouple

°C µV °C µV °C °C °CµV µV µV

500 4471 760 7461 1020 1280 154010771 14347 18012

510 4580 770 7583 1030 1290 155010905 14488 18152

520 4690 780 7705 1040 1300 156011039 14629 18292

530 4800 790 7823 1050 1310 157011173 14770 18431

540 4910 800 7950 1060 1320 158011307 14911 18571

550 5021 810 8073 1070 1330 159011442 15052 18710

560 5133 820 8197 1080 1340 160011578 15193 18849

570 5245 830 8321 1090 1350 161011714 15334 18988

580 5357 840 8446 1100 1360 162011850 15475 19126

590 5470 850 8571 1110 1370 163011986 15616 19264

600 5583 860 8697 1120 1380 164012123 15758 19402

610 5697 870 8823 1130 1390 165012260 15899 19540

620 5812 880 8950 1140 1400 166012397 16040 19677

630 5926 890 9077 1150 1410 167012535 16181 19814

640 6041 900 9205 1160 1420 168012673 16323 19951

650 6157 910 9333 1170 1430 169012812 16464 20087

660 6273 920 9461 1180 1440 170012950 16605 20222

670 6390 930 9590 1190 1450 171013089 16746 20356

680 6507 940 9720 1200 1460 172013228 16887 20488

690 6625 950 9850 1210 1470 173013367 17028 20620

750 7340 1010 10638 1270 1530 179014207 17872 -

740 7220 1000 10506 1260 1520 178014066 17732 -

730 7100 990 10374 1250 1510 177013926 17591 -

720 6980 980 10242 1240 1500 176013786 17451 21003

710 6861 970 10111 1230 1490 175013646 17310 20877

700 6743 960 9980 1220 1480 174013507 17169 20749K

Page 179: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

K3

Temperature-emf for Type S Thermocouple

°C µV °C µV °C °C °CµV µV µV

500 4233 760 6913 1020 1280 15409819 12917 16062

510 4332 770 7020 1030 1290 15509935 13038 16182

520 4432 780 7128 1040 1300 156010051 13159 16301

530 4532 790 7236 1050 1310 157010168 13280 16420

540 4632 800 7345 1060 1320 158010285 13402 16539

550 4732 810 7454 1070 1330 159010403 13523 16658

560 4833 820 7563 1080 1340 160010520 13644 16777

570 4934 830 7673 1090 1350 161010638 13766 16895

580 5053 840 7783 1100 1360 162010757 13887 17013

590 5137 850 7893 1110 1370 163010875 14009 17131

600 5239 860 8003 1120 1380 164010994 14130 17249

610 5341 870 8114 1130 1390 165011113 14251 17366

620 5443 880 8226 1140 1400 166011232 14373 17483

630 5546 890 8337 1150 1410 167011351 14494 17600

640 5649 900 8449 1160 1420 168011471 14615 17717

650 5753 910 8562 1170 1430 169011590 14736 17832

660 5857 920 8674 1180 1440 170011710 14857 17947

670 5961 930 8787 1190 1450 171011830 14978 18061

680 6065 940 8900 1200 1460 172011951 15099 18174

690 6170 950 9014 1210 1470 173012071 15220 18285

750 6806 1010 9703 1270 1530 179012796 15942 -

740 6699 1000 9587 1260 1520 178012675 15822 -

730 6593 990 9472 1250 1510 177012554 15702 -

720 6486 980 9357 1240 1500 176012433 15582 18609

710 6381 970 9242 1230 1490 175012312 15461 18503

700 6275 960 9128 1220 1480 174012191 15341 18395

°C µV °C µV °C °C °CµV µV µV

10 0391 110 4750 210 310 -9822 15445 -

20 0790 120 5228 220 320 -10362 16032 -

30 1196 130 5714 230 330 -10907 16624 -

40 1612 140 6206 240 340 -11458 17219 -

50 2036 150 6704 250 350 -12013 17819 -

60 2468 160 7209 260 360 -12574 18422 -

70 2909 170 7720 270 370 -13139 19030 -

80 3358 180 8237 280 380 -13709 19641 -

90 3814 190 8759 290 390 -14283 20255 -

100 4279 200 9288 300 400 -14862 20872 -

Temperature-emf for Type T Thermocouple

K

°C µV °C µV °C °C °CµV µV µV

10 0591 110 6998 210 310 41014164 21817 29747

20 1192 120 7685 220 320 42014912 22600 30550

30 1801 130 8379 230 330 43015664 23386 31354

40 2420 140 9081 240 340 44016420 24174 32159

50 3048 150 9789 250 350 45017181 24964 32965

60 3685 160 10503 260 360 46017945 25757 33772

70 4330 170 11224 270 370 47018713 26552 34579

80 4985 180 11951 280 380 48019484 27348 35387

90 5648 190 12684 290 390 49020259 28146 36196

100 6319 200 13421 300 400 50021036 28946 31005

Temperature-emf for Type E Thermocouple

Page 180: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

K4

Temperature-emf for Type B Thermocouple

°C µV °C µV °C °C °CµV µV µV

600 1792 860 3626 1120 1380 16405976 8731 11731

610 1852 870 3708 1130 1390 16506075 8844 11848

620 1913 880 3790 1140 1400 16606175 8956 11965

630 1975 890 3873 1150 1410 16706276 9069 12082

640 2037 900 3957 1160 1420 16806377 9182 12199

650 2101 910 4041 1170 1430 16906478 9296 12316

660 2165 920 4127 1180 1440 17006580 9410 12433

670 2230 930 4213 1190 1450 17106683 9524 12549

680 2296 940 4299 1200 1460 17206786 9639 12666

690 2363 950 4387 1210 1470 17306890 9753 12782

700 2431 960 4475 1220 1480 17406995 9868 12898

710 2499 970 4564 1230 1490 17507100 9984 13014

720 2569 980 4653 1240 1500 17607205 10099 13130

730 2639 990 4743 1250 1510 17707311 10215 13246

740 2710 1000 4834 1260 1520 17807417 10331 13361

750 2782 1010 4926 1270 1530 17907524 10447 13476

760 2854 1020 5018 1280 1540 18007632 10563 13591

770 2928 1030 5111 1290 1550 18107740 10679 13706

780 3002 1040 5205 1300 1560 18207848 10796 13820

790 3078 1050 5299 1310 1570 18307957 10913 -

850 3546 1110 5878 1370 1630 18908620 11614 -

840 3466 1100 5780 1360 1620 18808508 11497 -

830 3386 1090 5682 1350 1610 18708397 11380 -

820 3308 1080 5585 1340 1600 18608286 11263 -

810 3230 1070 5489 1330 1590 18508176 11146 -

800 3154 1060 5394 1320 1580 18408066 11029 -

Temperature-emf for Type C Thermocouple

°C µV °C µV °C °C °CµV µV µV

10 135 260 414 510 760 10108849 13723 1844

20 272 270 4319 520 770 10209044 13916 18623

30 412 280 45 530 780 10309239 14109 18805

40 554 290 4681 540 790 10409434 14302 18987

50 698 300 4863 550 800 10509629 14494 19168

60 845 310 5047 560 810 10609824 14686 19349

70 993 320 5231 570 820 107010019 14877 19529

80 1144 330 5416 580 830 108010215 15069 19709

90 1296 340 5601 590 840 10901041 1526 19888

100 1451 350 5788 600 850 110010606 1545 20066

110 1607 360 5975 610 860 111010810 1564 20244

120 1765 370 6163 620 870 112010997 1583 20421

130 1925 380 6352 630 880 113011192 1602 20598

140 2087 390 6541 640 890 114011388 16208 20774

150 225 400 6731 650 900 115011583 16397 2095

160 2415 410 6921 660 910 116011778 16585 21125

170 2581 420 7112 670 920 117011974 16773 21299

180 2749 430 7304 680 930 118012169 1696 21473

190 2918 440 7496 690 940 119012364 17147 21647

200 3089 450 7688 700 950 120012558 17333 21819

250 3962 500 8655 750 1000 125013529 18257 22674

240 3785 490 8461 740 990 124013336 18073 22504

230 3609 480 8267 730 980 123013142 17889 22334

220 3434 470 8074 720 970 122012947 17704 22163

210 3261 460 7881 710 960 121012753 17519 21991K

Page 181: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

K5

Standards for Cables

JSS AND MIL STANDARDS

JSS 51034:1992 For Fluoropolymer Insulated wire

JSS 51037:1992 For Fluorocarbons / Polymide Insulated wire

JSS 51038:1992 For special purpose shielded and Unshielded cable

MIL-W-16878E Specification for Unshielded wire for Hook up & Lead

ASTM & ANSI STANDARDS

ASTM-B-298-07 For Silver Coated soft or annealed round copper wire

ASTM B33-10 For Tinned Coated soft or annealed round copper wire

ASTM B355-95 For Nickel Coated soft or annealed round copper wire

ASTM E230/77 For the tolerance in thermocouple conductor

ANSI MC 96.1 Specified Colour code and tolerance of thermocouple conductor

Indian (IS) STANDARDS

IS 1554:88 PART 1 PVC Sheathed Power Cable for working voltage Up to and including 1100V

IS 2848-1986 Specification for RTD Cable

IS 694 : 1990 PVC Insulated Cable for working voltage Up to and including 1100V

IS 8130:84 Specification for Conductors for insulated electric Cable

IS 10810:1984 Method of Tests for Cables

IS 5608 :1976 ,PART III Low frequency wires and cables with PVC Insulated & PVC Sheathed

IS 7098 : 1988,PART I For XLPE Insulated Thermoplastic Sheathed cables

IS 10418 : 1982 Specification for Drums for electric Cable

IS 2054 : 1962 For Ni-Cr / Ni-Al Thermocouples

IS 2055 : 1962 For Pt-Rh / Pt Thermocouples

IS 9968 : 1988 Specifications for Silicon Insulated Cable

IS 8784 Specifications for Compensating Cables

IS 5831:84 Specifications for PVC Insulation and Sheath of Electrical Cables

IS 3975:99 Specifications for Galvanized Armoured wire of electrical cables

IEC STANDARDS

IEC 60092-351 Insulations materials for electric cables

IEC 60092-353 Electric installations in ships. Single and multicore cables with nominal voltage U0/U 0.6/4 Kv

IEC 60092-359 Sheathing materials for electric cables

IEC 60092-376 Cable for control and instrumentation circuits 150/250V (330V)

IEC 60228 Conductors of insulated cables. Guide to dimensional limits of circular conductor.

IEC 60331 Test for electric cables under fire conditions. Circuit integrity

IEC 60332 Test of flame retardant for electric cables

IEC 60754-1 Amount of halogen acid gases evolved during combustion of polymeric materials

IEC 60754-2 Acidity of gases (PH) and conductivity

IEC 60584 Thermal E.M.F. values for Thermocouples

IEC 60811 Common test methods for insulating and sheathing materials of electric cables

IEC 61034 Smoke density test for electric cables under fire condition.

Test of halogen acid gases emitted by cables under fire condition BS 6425 Part 1

Specifications for armoured cables for electric supply having thermosetting insulation with low emission of smoke and corrosive gases when affected by fire

BS 5724

Flame retardant cables for off shore plantBS 6883

BS STANDARDS

BS 1843 Colour code for twin compensating cables for thermocouples

BS 4066 Tests on electric cables under fire conditions

BS 4937 Thermocouple reference tables.

BS 5308 Part 1 Instrumentation cables - Specifications for PE insulated cables.

BS 5308 Part 2 Instrumentation cables - Specifications for PVC insulated cables.

BS 5467Cables with thermosetting insulation for electricity supply for rated voltage up to and

including 600/1000V

PE insulated cables for electricity supplyBS 6234

PVC insulated cables for electricity supplyBS 6346

Conductors for insulated cablesBS 6360

Performance requirements for cables required to maintain circuit integrity under fire conditionsBS 6387

Insulation and sheath materials for electric cablesBS 7655

Fire resistant cablesBS 7917

Steel wire armours for electric cablesBS EN10257-1

K

Page 182: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

K6

SWG = (BRITISH) STANDARD WIRE GAUGE B & S = BROWN AND SHARPE AWG = AMERICAN WIRE GAUGE

0 0.324 8.23 0.3249 8.25 1 0.300 7.62 0.2893 7.35 2 0.276 7.01 0.2576 6.54 3

0.252

6.40

0.2294

5.83

4

0.232

5.89

0.2043

5.19

5

0.212

5.38

0.1819

4.62

6

0.192

4.88

0.1620

4.11

7

0.176

4.47

0.1443

3.67 8

0.160

4.06

0.1285

3.26

9

0.144

3.66

0.1144

2.91 10

0.128

3.25

0.1019

2.59

11

0.116

2.95

0.0907

2.3 12

0.104

2.64

0.0808

2.05

13

0.092

2.34

0.0720

1.83

14

0.080

2.03

0.0641

1.63

15

0.072

1.83

0.0571

1.45

16

0.064

1.63

0.0508

1.29

17

0.056

1.42

0.0453

1.15

18

0.048

1.22

0.0403

1.02

19

0.040

1.02

0.0359

0.912

20

0.036

0.914

0.0320

0.813

21

0.032

0.813

0.0285

0.724

22

0.028

0.711

0.0253

0.643

23

0.024

0.610

0.0226

0.574

24 0.022 0.559 0.0201 0.511

25 0.020 0.508 0.0179 0.455

No. SWG B & S(AWG)

inches mm inches mm

26 0.018 0.457 0.0159 0.404 27 0.0164 0.417 0.0142 0.361 28 0.0148 0.376 0.0126 0.320 29

0.0136

0.345

0.0113

0.287

30

0.0124

0.315

0.0100

0.254

31

0.0116

0.295

0.0089

0.226

32

0.0108

0.274

0.0080

0.203 33

0.0100

0.254

0.0071

0.180

34

0.0092

0.234

0.0063

0.160 35

0.0084

0.213

0.0056

0.142

36

0.0076

0.193

0.0050

0.127 37

0.0068

0.173

0.0045

0.114

38

0.006

0.152

0.0040

0.102

39

0.0052

0.132

0.0035

0.089

40

0.0048

0.122

0.0031

0.079

41

0.0044

0.112

0.0028

0.071

42

0.0040

0.102

0.0025

0.064

43

0.0036

0.091

0.0022

0.056

44

0.0032

0.081

0.0020

0.051

45

0.0028

0.071

0.0018

0.046

46

0.0024

0.061

47

0.0020

0.051

48

0.0016

0.041

49

0.0012

0.030

50 0.0010 0.025

No. SWG B & S(AWG)

inches mm inches mm

Conductor Size Equivalents (Diameter)

Specifications of PTFE Wires (AS PER JSS 51034)

Size Dia of Cross Max Resistance CurrentCond- Sectional of Conductor Ratinguctor area OHMS/KM

AWG AWG (mm) (mm) mm2 Min(mm)Max(mm) Min(mm) Max(mm)Min(mm) Max(mm) at 20°C (amps)

32 7/40 7/0.08 0.25 0.035 0.50 0.60 0.66 0.86 0.91 1.11 567 0.730 1/30 1/0.25 0.25 0.049 0.50 0.60 0.66 0.86 0.91 1.11 354 1.030 7/38 7/0.10 0.31 0.055 0.55 0.66 0.71 0.91 0.96 1.16 330 1.028 1/28 1/0.32 0.32 0.080 0.58 0.68 0.73 0.93 0.99 1.19 223 2.128 7/36 7/0.13 0.38 0.093 0.63 0.73 0.78 0.99 1.04 1.24 209 2.126 1/26 1/0.40 0.40 0.125 0.66 0.76 0.81 1.01 1.06 1.27 140 3.026 7/34 7/0.16 0.48 0.140 0.73 0.83 0.88 1.09 1.14 1.34 132 3.026 19/38 19/0.10 0.51 0.149 0.73 0.83 0.88 1.09 1.14 1.34 125 3.024 1/24 1/0.51 0.51 0.204 0.76 0.86 0.91 1.11 1.16 1.37 87 4.024 7/32 7/0.20 0.61 0.219 0.86 0.96 1.01 1.21 1.27 1.47 82 4.024 19/36 19/0.13 0.64 0.252 0.86 0.96 1.01 1.21 1.27 1.47 79 4.022 1/22 1/0.64 0.64 0.321 0.88 1.01 1.04 1.27 1.29 1.52 55 7.322 7/30 7/0.25 0.76 0.343 1.01 1.11 1.16 1.37 1.42 1.62 52 7.322 19/34 19/0.16 0.81 0.382 1.01 1.11 1.16 1.37 1.42 1.52 49 7.320 1/20 1/0.81 0.81 0.515 1.06 1.16 1.21 1.42 1.47 1.67 34 11.020 7/28 7/0.32 0.97 0.562 1.21 1.32 1.37 1.57 1.62 1.82 32 11.020 19/32 19/0.20 1.02 0.596 1.21 1.32 1.37 1.57 1.62 1.82 30 11.018 7/26 7/0.40 1.22 0.879 1.63 1.87 1.87 2.13 20 16.018 19/30 19/0.25 1.27 0.932 1.63 1.87 1.87 2.13 18 16.016 19/29 19/0.29 1.45 1.254 1.85 2.20 2.10 2.41 14 22.015 19/28 19/0.32 1.60 1.528 1.98 2.28 2.26 2.54 12 26.014 19/27 19/0 36 1 83 1 933 2.23 2.59 2.48 2.89 9 32.013 19/26 19/0.40 2.00 2.387 2.43 2.74 2.66 3.02 7 35.012 19/25 19/0.45 2.31 3.021 2.71 3.07 2.97 3.37 5 41.012 37/28 37/0.32 2.26 2.975 2.66 3.02 2.92 3.32 6 41.011 19/24 19/0.50 2.50 3.730 2.99 3.30 3.20 3.58 4 45.010 19/22 19/0.65 3.25 6.304 3.73 4.03 3.96 4.34 2 55.010 37/26 37/0.4 2.82 4.649 3.22 3.58 3.47 3.88 3 50.08 133/29 133/0.29 4.29 8.784 5.05 5.56 2 75.06 133/27 133/0.36 5.41 13.537 6.42 6.93 1 100.0

each Strand Insulation Insulation Insulation

Number of ET 250 V E 600 V EE 1000 VStrands / Dia of OD of OD of OD of

K

Page 183: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2
Page 184: Cable Product Guide - Tempsens Instruments Pvt. LtdIt101 - IT 117 PTFE / PTFE / BC Screen / VFG..... XLPE Insulated IX101 - IX115 XLPE / Almylar Screen / PVC / GI / PVC..... C1 C2

www.tempsens.com

Tempsens Instruments GmbHLoehestrasse 37,53773 Hennef, GERMANYPh.:+49-2242-8703-22Fax.:+49-2242-8703-20Email: [email protected]

Germany