Cable Cubby 500 and 700 Installation Guide - Home |...

6

Transcript of Cable Cubby 500 and 700 Installation Guide - Home |...

Page 1: Cable Cubby 500 and 700 Installation Guide - Home | Extronmedia.extron.com/download/files/userman/68-2491-50_B.pdf · Cable Cubby 500 and 700 • Installation Guide instructions,

1

IMPORTANT:

Go to www.extron.com for the

complete user guide, installation

instructions, and specifications.

Cable Cubby 500 and 700 • Installation Guide

This guide provides instructions for an experienced installer to install and connect the Extron Cable Cubby 500 and 700 Cable Access Enclosures.

The Cable Cubby units are furniture-mounted enclosures for cable access, connections, and AC power. Cables that are not in use can be stored out of the way while remaining connected to the presentation system.

Cable Cubby 500 Cable Cubby 700

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

1 2

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

2 4

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

1 2

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

1 2

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k(3) 3/8", (1) 1/4" (6) 3/8", (2) 1/4"

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

1 trim, 2 screws 2 trims, 4 screws

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

1 2Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

4 8

Planning

Check with local and state regulations before starting the installation:

� Ensure that the planned installation complies with building and electrical codes.

� Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements.

Check all parts and equipment before installation: � Ensure that all parts are present in each kit.

� Ensure that necessary tools and equipment are available for the installation.

Kit Contents

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

Hole Plugs

Connectivity Bracket Cable Grommet Plate

AAP Frame Plate

Cable Cubby 500 Cable Cubby 700

Zip Ties

Tweeker AC Power Module

125V~ 12A MAX TOTAL

Retractor Trim and Screws

Retractor Pin & Clip

#6 Mounting Screws and Star Washers

#4-40 Module Screws

i i B k

Page 2: Cable Cubby 500 and 700 Installation Guide - Home | Extronmedia.extron.com/download/files/userman/68-2491-50_B.pdf · Cable Cubby 500 and 700 • Installation Guide instructions,

Cable Cubby 500 and 700 • Installation Guide (Continued)

2

x.x"(x.x cm)

x.x"(x.x cm)

x.x"(x.x cm)

x.x"(x.x cm)

30

Table Top

x.x"(x.x cm)

x.x"(x.x cm)

XL Models

x.x"(x.x cm)

x.x"(x.x cm)

x.x"(x.x cm)

XL Models

23.5"(59.7 cm)

29.4"(74.7 cm)

26.7"(67.8 cm)

10.6"(26.9 cm)

30

Table Top

XL Models

9.1"(23.1 cm)

15.9"(40.4 cm)

21.9"(55.6 cm)

XL Models

3.0"(7.6 cm)

3.0"(7.6 cm)

Preparing the TableCut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.

Determine the best location for the enclosure

� Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. � Ensure that the edge on which the lid opens is oriented correctly. � Ensure that there is ample space under the table for cables. � When installing retractors in the Cable Cubby, ensure that there is enough space for the retractor assembly under the table or furniture (ee dimensions for the retractors below).

Choose a method for cutting the hole in the table

ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to prevent scarring or damaging the furniture.

ATTENTION: L’ouverture dans la table pour le Cable Cubby devrait être coupée seulement par des artisans autorisés et qualifiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.

CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.

ATTENTION: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut conduire à une blessure à l’oeil.

Choose one of the following methods for cutting the hole:

Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router

If using a CNC wood router or other precise machinery, use the exact cut-out dimensions for your model (see the table below).

Visit www.extron.com for Cable Cubby routing template part numbers and instructions.

Dimensions and cut-out templates are available online at www.extron.com.

ProductCut-out Dimensions

User Access Width

Side Dimension

CC 500 5.75"(14.6 cm)

5.75"(14.6 cm)

CC 700 7.125"(18.1 cm)

5.75"(14.6 cm)

NOTES:• To prevent objects from impeding cable retraction, ensure at least 3 inches of clearance from the exposed cable side of

the enclosure (see the diagrams below).• Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or

entanglement (see Routing and Connecting Cables on page 6).

Cut-Out Template for the Extron

Cable Cubby 500

0.25"(0.635 cm) R

User Access

5.75"(14.60 cm)

5.75"(14.60 cm)0.25"

Trim RingLip Width

2.0"

Trim Ring’s Outer Edge

(Do not cut this line.)

0.00” (0.00 cm)

0.02 (0.05 cm)

+

Table Clamp

P/N 68-8599-01 Rev. A

SURFACECUT-OUTAREA

1. Confirm the product to be installed.

2. Remove the surface cut-out area

(gray) from the template.

3. Measure the cutout and template.

4. Mark the position on the

furniture where the Cable Cubby 500

will be installed.

5. Double check dimensions and position,

then cut the opening.

Page Size: 11" x 17"

Print Scale 1:1

Do not Shrink

0.25"(0.635 cm) R

5.75"(14.60 cm)

5.75"(14.60 cm)

SURFACECUT-OUTAREA

Cut-Out Template for the Extron

Cable Cubby 500

User Access

0.25"Trim Ring

Lip Width

2.0"

Trim Ring’s Outer Edge

(Do not cut this line.)

0.00” (0.00 cm)

0.02 (0.05 cm)

+

Table Clamp

P/N 68-8599-01 Rev. A

1. Confirm the product to be installed.

2. Remove the surface cut-out area

(gray) from the template.

3. Measure the cutout and template.

4. Mark the position on the

furniture where the Cable Cubby 500

will be installed.

5. Double check dimensions and position,

then cut the opening.

Page Size: 11" x 17"

Print Scale 1:1

Do not Shrink

Jigsaw

Cut OCut-Out Te

CCab

Page 3: Cable Cubby 500 and 700 Installation Guide - Home | Extronmedia.extron.com/download/files/userman/68-2491-50_B.pdf · Cable Cubby 500 and 700 • Installation Guide instructions,

3

Preparing the Cable CubbyStep 1 — Assemble the connectivity modules of your choice.

NOTE: • Use a screwdriver to secure the

Retractor trim with the screws.

• After installing the retractor trim, proceed to Step 2 — Install the modules on the next page to install the power module.

• Retractors are installed after the Cable Cubby is mounted on the table (see Installing Retractors on page 5).

AAP Module

Cable Pass-Through Module

Retractor Trim Secure the retractor trim

using the provided mounting screws (2).

Connectivity modules allow you to populate the Cable Cubby with a combination of AAPs, cable pass-through, or retractors.

NOTE: After assembling the module, proceed to Step 2 — Install the modules on the next page.

NOTE: After assembling the module, proceed to Step 2 — Install the modules on the next page.

Secure up to two single-space AAPs in the AAP plate.

#4-40 Nut w/ Captive Washer

Insert cables through the bottom of the connectivity bracket. Connect cables to the AAPs.

Secure the AAP plate on the connectivity brackets, using two of the provided module screws.

Insert cables through the bottom of the connectivity bracketand into the holes of the grommet plate.

Secure the grommet plate on the connectivity bracket using twoof the provided module screws.

Snap the included hole plugs into any unused holes.

1

2

3

1

2

3

Secure up to two single-space AAPs in the AAP plate.

#4-40 Nut w/ Captive Washer

Insert cables through the bottom of the connectivity bracket. Connect cables to the AAPs.

Secure the AAP plate on the connectivity brackets, using two of the provided module screws.

Insert cables through the bottom of the connectivity bracketand into the holes of the grommet plate.

Secure the grommet plate on the connectivity bracket using twoof the provided module screws.

Snap the included hole plugs into any unused holes.

1

2

3

1

2

3

Page 4: Cable Cubby 500 and 700 Installation Guide - Home | Extronmedia.extron.com/download/files/userman/68-2491-50_B.pdf · Cable Cubby 500 and 700 • Installation Guide instructions,

4

Insert the modules into the Cable Cubby.

125V~ 12A MAX TOTAL

Secure the modules usingthe provided mounting screws and star washers (4) on the front and back of the enclosure.

125V~ 12A MAX TOTAL

1

2

Step 1 — Mount the Cable Cubby flush with the table.

CAUTION: The flanged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.

ATTENTION: Les extrémités à brides du haut de la surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses et peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier afin d’éviter de l’endommager ou de vous blesser.

Mounting the Cable Cubby in the Table

Step 2 — Install the modules.Determine where the connectivity modules and power module will be installed in the Cable Cubby. The modules may be installed on the left or right side of the enclosure and at various heights.

NOTE:

• Ensure that there is enough room above the modules for the Cable Cubby lid to close completely.

• Use a screwdriver to secure the modules with the screws.

Lower the Cable Cubby into the hole to test the �t. If necessary, carefully enlarge the opening.

Remove the plastic strips and �lm on the surface of the Cable Cubby.

Ensure that the side clamps are seated against the enclosure.

Secure cables with zip ties to the rectangularholes in the rear of the Cable Cubby.

For cable pass-through applications, allow at least 36 inches (0.9 m) of cable loop for each cable.

Connect cables to the AV system and connect the AC power cord.

Rotate the side clamp outward and ensure that the lever is down.

Slide the clamp all the way up against the bottom of the table.

Ensure the Cable Cubby is �rmly seated in the table. Raise the lever to secure the Cable Cubby.

Lever

1

2

3

2

1

3

1 2 3

WARNING: Risk of Electric Shock. To ensure proper electrical grounding, use the provided #6-32 mounting screws with the star washers.

AVERTISSEMENT: Risque de choc électrique. Afin d’assurer une mise à la terre correcte, utilisez les fixations de mise à la terre #6-32 et les rondelles en étoile fournies.

Page 5: Cable Cubby 500 and 700 Installation Guide - Home | Extronmedia.extron.com/download/files/userman/68-2491-50_B.pdf · Cable Cubby 500 and 700 • Installation Guide instructions,

5

Cable Cubby 500 and 700 • Installation Guide (Continued)

Step 2 — Under the table, adjust the side clamps on the enclosure.

Installing Retractors

NOTE: To lower the side clamp, turn the lever down, then press and hold the locking plate while sliding down the clamp.

Lockingplate

Horizontal or Angular Mounting

For installation details, see the Cable Retractor Setup Guide available online at www.extron.com.

Secure the clip on the pin.

Insert retractors into the retractor trim.

Secure the locking screw on each retractor. Do not overtighten.

Insert the pin through the retractor mounting hole on the side of the Cable Cubby and retractor assembly.

1

2

3

4

Insert the pin through the retractor mounting hole on the side of the Cable Cubby and retractor assembly.

Secure the clip on the pin.

Insert retractors into the retractor bracket.

Secure the locking screw on eachretractor. Do not overtighten.

For horizontal or angular mounting, remove these orientation screws (front and back), then follow the steps shown at left.

Rotate the side clamp outward and ensure that the lever is down.

Slide the clamp all the way up against the bottom of the table.

Ensure the Cable Cubby is �rmly seated in the table. Raise the lever to secure the Cable Cubby.

Lever

21 3

2

3

1

4

Lower the Cable Cubby into the hole to test the �t. If necessary, carefully enlarge the opening.

Remove the plastic strips and �lm on the surface of the Cable Cubby.

Ensure that the side clamps are seated against the enclosure.

Secure cables with zip ties to the rectangularholes in the rear of the Cable Cubby.

For cable pass-through applications, allow at least 36 inches (0.9 m) of cable loop for each cable.

Connect cables to the AV system and connect the AC power cord.

Rotate the side clamp outward and ensure that the lever is down.

Slide the clamp all the way up against the bottom of the table.

Ensure the Cable Cubby is �rmly seated in the table. Raise the lever to secure the Cable Cubby.

Lever

1

2

3

2

1

3

1 2 3

Page 6: Cable Cubby 500 and 700 Installation Guide - Home | Extronmedia.extron.com/download/files/userman/68-2491-50_B.pdf · Cable Cubby 500 and 700 • Installation Guide instructions,

68-2491-50 Rev. B05 14

6

Extron Headquarters+800.633.9876 Inside USA/Canada Only

Extron USA - West Extron USA - East+1.714.491.1500 +1.919.850.1000

+1.714.491.1517 FAX +1.919.850.1001 FAX

Extron Europe+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron Asia+65.6383.4400

+65.6383.4664 FAX

Extron Japan+81.3.3511.7655

+81.3.3511.7656 FAX

Extron China+86.21.3760.1568

+86.21.3760.1566 FAX

Extron Middle East+971.4.299.1800

+971.4.299.1880 FAX

Extron Korea+82.2.3444.1571

+82.2.3444.1575 FAX

Extron India1800.3070.3777

(Inside India Only)

+91.80.3055.3777

+91.80.3055.3737 FAX

© 2014 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com

Installation ChecklistPlanning (page 1)

� Check with local and state regulations before starting the installation.

� Check all parts and equipment before installation.

Preparing the Table (page 2) � Determine the best location for the enclosure.

� Choose a method for cutting the hole in the table.

Preparing the Cable Cubby (page 3) � Choose and assemble a combination of AAPs, cable-pass through, and retractor connectivity to populate

the Cable Cubby.

� Secure the connectivity modules and power module in the Cable Cubby.

Mounting the Cable Cubby in the Table (page 4) � Mount the Cable Cubby flush with the table.

� Adjust the side clamps.

Installing Retractors (page 5)

Routing and Connecting Cables (page 6)

Routing and Connecting Cables

Lower the Cable Cubby into the hole to test the �t. If necessary, carefully enlarge the opening.

Remove the plastic strips and �lm on the surface of the Cable Cubby.

Ensure that the side clamps are seated against the enclosure.

Secure cables with zip ties to the rectangularholes in the rear of the Cable Cubby.

For cable pass-through applications, allow at least 36 inches (0.9 m) of cable loop for each cable.

Connect cables to the AV system and connect the AC power cord.

Rotate the side clamp outward and ensure that the lever is down.

Slide the clamp all the way up against the bottom of the table.

Ensure the Cable Cubby is �rmly seated in the table. Raise the lever to secure the Cable Cubby.

Lever

1

2

3

2

1

3

1 2 3

CAUTION: Risk of Electric Shock. This equipment must be grounded.

ATTENTION: Risque de choc électrique. Cet équipement doit être fixé au sol.

NOTE: Ensure that there is no tension on the power cable.