C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to...
Transcript of C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to...
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
C P
T A
37
CCompany
PProducts
A
Application
T
Technology
Hot Runner Manifolds
Series VC
M
A
Z
B
C
E
J2
1)
2)
2)
12...20
11.5...28
0...0.16
30 / 40
15...50
Ø29...Ø69
Ø61 / Ø74
Ø72 / Ø85
3
4
5
6
1
2
8
7
A
B
Z
C
E
De1
De2
De3
37 mm
max. Ø12 mm
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Hardened insert recommended; is not supplied
with the hot runner system.
Values of these dimensions depend on the
selected nozzle or on the selected material. They
can be found in the Synventive Hot Runner Guide.
Hot runner manifolds
Product type
Hot runner manifold of series which are
characterised by the following dimensions:
The manifolds can be supplied
( )
ised .
The runners of standard manfiolds are
mechnanically balanced.
VC
in standard
shapes I, H, X, Y and in any realisable
custom shape
Series
M
J2
page no. of related data sheets
VC
Major dimensions (mm)
Components
3. Centre support
4. Support pillar
5. Dowel
6. Fastening screw
7. Support pad
8. Isolation bushing
1. Manifold block including heaters,
connections and thermocouple
2. Inlet bushing (including heater)
Melt flow components
Attached parts and accessories
Manifold cut out, right (above)
Manifold cut out, left (below)
Expansion gap
Height centre support
Height inlet bushing
Ø of contact inlet bushing
Ø of cut out inlet bushing
Ø of cut out isolation bushing
Thickness
Flow bore Ø
1)
2)
1 / 44
C P
T A
VC
2
2
2
2
Lpl
AD
1
2
Jib1
(mm)
R
(mm)
AD
(°)
Dpl
(mm)
Lpl
(mm)
De2
(mm)
De1
(mm)
E
(mm)
Heater
power
(Watt)
E
A
X
Y
E
- - -
AD=
AD=
Dpl=
Dpl=
Lpl=
Lpl=
R=
R=
AB
AB L Y
16
K A 15 56 61 Ø8 max. 40 90 / 120 - - -
K X 15 56 61 Ø8 max. 40 90 / 120 - - -
K Y 15 56 61 Ø8 max. 40 90 / 120 - - -
M 06 001 35 29 - Ø6 max. 40 90 / 120 - - 180
M 08 001 35 29 - Ø8 max. 40 90 / 120 - - 180
L A 50 69 74 Ø8 max. 40 90 / 120 - - 630
L X 50 69 74 Ø8 max. 40 90 / 120 - - 630
L Y 50 69 74 Ø8 max. 40 90 / 120 - - 630
T A 50 69 74 Ø8 max. 40 90 / 120 max. Ø25 max. 30 630
T X 50 69 74 Ø8 max. 40 90 / 120 max. Ø25 max. 30 630
T Y 50 69 74 Ø8 max. 40 90 / 120 max. Ø25 max. 30 630
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Inlet bushings
Series
2. Selection of variables
Example and explanations
Type
Type
Here you can configure your inlet bushing
1. Complete the inlet bushing description
Inlet
bushing
long bushing
with Y shaped hole pattern
The hole pattern can be found in the manifold
data sheets.
For the inlet bushing type M the code for the hole
pattern is replaced by the code for flow channel
and version.
1)
2)
Inlet bushings which can be combined with
hot runner manifolds of series :VC
1. ABK ... / ABL ... / ABT ...
2. ABM ...
è
è
è
è
two styles:
three different hole patterns for
the attachment to the manifold
bore for decompression machine nozzle
possible
can be combined with isolation bushing
è
è
è
one length and always heated
two different flow bore-Ø possible
universal hole pattern for all manifold types
à
à
short and not heated
long and heated
Variables for precise part specification
from the drawings and tables shown here
1)
Type
Part code
Part code
2)
2 / 44
C P
T A
B
M
3
VC
MCS 30 30 40
MSPL 09 20
MCS 30 30 50
MSPL 09 40
40
20
max. 26
max. 20
max. 36
max. 40
50
40
Lcs
(mm)
Lsp
(mm)
B
(mm)
B
(mm)
30 40
C (mm)
03 / 04 / 07 12
2)
2)
A
Z
B
C
1
4
6
2
5
1
5
6
2
3
4
Lcs
Lms
MS 30 15 t
ZAB 056 50
MS 30 30 t
ZAB 069 50
15
56 61 72 ABK/ABM
max. 15
max. 3030
69 74 85 ABL/ABT
Lms
(mm)
De1
(mm)
De2
(mm)
De3
(mm)
A
(mm)
2)
3)
3)
Lsp
De1
De2
De3
Z (mm)
0 ... 0.16
2)
1)
1. MCS 30 30 ...
2. MSPL ...
5. MS 30 ...
6. ZAB ...
4. DIN6325: 6 m6 x45 / 8 m6 x45
3. DIN 912: M6 / M8
M
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
1)
2)
3)
Hardened insert recommended; is not supplied
with the hot runner system.
Values of these dimensions depend on the
selected nozzle or on the selected material. They
can be found in the Synventive Hot Runner Guide.
Depending on manifold size and installation
space.
for
Centre
support
Support pad
Attached parts and accessories
Series
Attached parts and accessories for hot runner
manifolds of series :VC
for nozzle size for nozzle size
Support
pillar
Isolation
bushing
èFastening screws
èDowel
èSupport pads are only used when they are
needed e g when face fit manifold nozzles are
used.
3 / 44
C P
T A
V1E
I2E
I3E Y3E
I4E X4E / XSEH4E
Y6E H6E
H8E
Y12E
X16E
X24E
X32E
1
2
3
4
6
8
12
16
24
32
I Y H X
1
2 3
VC
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Shape of manifold / runner layout inside manifold
No. of nozzles
Available manifold types
Customised manifolds Brigde manifolds
Manfold types and styles
Series
1. Manifolds in standard shape
2. Manifolds in customised shape
3. Bridge manifolds
Manifolds in standard shape
Shape of manifod resp. runner layout
inside the manfold
Number of nozzels fed by the manifold
Available manifold types: see right
are available in
different basic layouts, so called manifold
types, in order to put different standard gating
layouts into practice.
The different manifold types can be described
by the following features:
è
è
Manifolds in customised shape
according to the customer’s
specification by using
are designed
and made
components of the
selected manifold series.
Bridge manifolds make it possible to combine
several manifold to one feed system. They
are are designed and made according to the
customer’s specification by using components
of the selected manifold series.
page no. of related data sheets
4 / 44
C P
T A
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
VC V1E 155 ...
Lx2
Lx
X
155 155 - 125 - 60 2 x 520 - - - 1040
175 175 - 145 - 80 2 x 600 - - - 1200
195 195 - 165 - 100 2 x 680 - - - 1360
*
*
J2 (mm)
max. 12
30 40
C (mm)
03 / 04 / 07 12
V1E
V1E
-
155
CB ... M
Y=X=
Y=X=
VC
VC
65
1)
2) 2)
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
1-port-I-manifold
1-port-I-manifold
Heater zones power (Watt)Length
code
for nozzle size for nozzle size
2)
Nozzle size manifold can be used with
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Plate bolts: M10 - 12.9 (2x per nozzle)
5 / 44
C P
T A
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
205 205 - 175 - 120 - 2 x 720 - - - 1440
225 225 - 195 - 140 - 2 x 560 - - - 1120
245 245 - 215 - 160 - 2 x 880 - - - 1760
265 265 - 235 - 180 - 2 x 672 - - - 1344
285 285 - 255 - 200 - 2 x 1040 - - - 2080
305 305 - 275 - 220 - 2 x 1150 - - - 2300
325 325 - 295 - 240 - 2 x 1200 - - - 2400
345 345 - 315 - 260 - 2 x 1280 - - - 2560
365 365 - 335 - 280 - 2 x 1360 - - - 2720
385 385 - 355 - 300 - 2 x 1260 - - - 2520
VC V1E 205 ...
Lx2
*
*
Lx
X
V1E
V1E
-
205
CB ... M
Y=X=
Y=X=
VC
VC
125
J2 (mm)
max. 12
30 40
C (mm)
03 / 04 / 07 12
1)
2) 2)
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
2)
Nozzle size manifold can be used with
Length
code
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
Heater zones power (Watt)
requested pitch
dimensions
Nozzle series the manifold
will be combined with
1-port-I-manifold
1-port-I-manifold
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Plate bolts: M10 - 12.9 (2x per nozzle)
6 / 44
C P
T A
VC I2E 170
Lx
X X
170 170 - - - 40 - 2 x 560 - - - 1120
J2 (mm)
max. 12
30
C (mm)
03 / 04 / 07
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
I2E
I2E
-
170
CB ... M
Y=X=
Y=X=
VC
VC
45
3)
4)
1)
2) 2)
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Length
code
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2-port-I-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
3)
4)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the nozzles!
In case of lack of space use next larger manifold
type.
for X < 40 mm
for X 40 mm
Heater zones power (Watt)
2-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
7 / 44
C P
T A
VC I2E 210
Lx
X X
210 210 - - - 60 - 2 x 720 - - - 1440
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
-
210
CB ... M
Y=X=
Y=X=
VC
VC
65
I2E
I2E
1)
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
03 / 04 / 07 12
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
2-port-I-manifold
2-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
8 / 44
C P
T A
VC I2E 250 ...
Lx
Lx2
X X
250 250 - 270 - 80 - 2 x 880 - - - 1760
290 290 - 310 - 100 - 2 x 1040 - - - 2080
330 330 - 350 - 120 - 2 x 1200 - - - 2400
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
J2 (mm)
max. 12
30
34.5
40
40.537.5
C (mm)
Lb (mm)
03 / 04 / 07
ABK
12
ABL/ABTABM
-
250
CB ... M
Y=X=
Y=X=
VC
VC
85
I2E
I2E
1)
2) 2)
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
2-port-I-manifold
2-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
9 / 44
C P
T A
VC I2E 370 ...
Lx2
Lx
X X
I2E
I2E
-
370
CB ... M
Y=X=
Y=X=
VC
VC
145
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
*
*
1)
J2 (mm)
max. 12
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
370 370 - 390 - 140 - 2 x 640 2 x 640 - - 2560
410 410 - 430 - 160 - 2 x 720 2 x 720 - - 2880
450 450 - 470 - 180 - 2 x 560 2 x 560 - - 2240
490 490 - 510 - 200 - 2 x 880 2 x 880 - - 3520
530 530 - 550 - 220 - 2 x 672 2 x 672 - - 2688
570 570 - 590 - 240 - 2 x 1040 2 x 1040 - - 4160
610 610 - 630 - 260 - 2 x 1150 2 x 1150 - - 4600
650 650 - 670 - 280 - 2 x 1200 2 x 1200 - - 4800
690 690 - 710 - 300 - 2 x 1280 2 x 1280 - - 5120
2) 2)
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
2-port-I-manifold
2-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
10 / 44
C P
T A
VC I3E 170 ...
Lx2
Lx
170 170 - 190 - 40 - 2 x 600 - - - 1200
210 210 - 230 - 60 - 2 x 760 - - - 1520
250 250 - 270 - 80 - 2 x 644 - - - 1288
290 290 - 310 - 100 - 2 x 756 - - - 1512
330 330 - 350 - 120 - 2 x 1200 - - - 2400
-
170
CB ... M
Y=X=
Y=X=
VC
VC
45
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
*
*
I3E
I3E
1)
X X
2) 2)
J2 (mm)
max. 12
C (mm)
03 / 04 / 07 12
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
3-port-I-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
3-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
11 / 44
C P
T A
VC I3E 370 ...
Lx2
Lx
X X
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
*
*
-
370
CB ... M
Y=X=
Y=X=
VC
VC
145
I3E
I3E
1)
2) 2)
370 370 - 390 - 140 - 2 x 680 2 x 680 - - 2720
410 410 - 430 - 160 - 2 x 760 2 x 760 - - 3040
450 450 - 470 - 180 - 2 x 588 2 x 588 - - 2352
490 490 - 510 - 200 - 2 x 644 2 x 644 - - 2576
530 530 - 550 - 220 - 2 x 1000 2 x 1000 - - 4000
570 570 - 590 - 240 - 2 x 756 2 x 756 - - 3024
610 610 - 630 - 260 - 2 x 1000 2 x 1000 - - 4000
650 650 - 670 - 280 - 2 x 1200 2 x 1200 - - 4800
690 690 - 710 - 300 - 2 x 1000 2 x 1000 - - 4000
J2 (mm)
max. 12
C (mm)
03 / 04 / 07 12
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
3-port-I-manifold
3-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
12 / 44
C P
T A
VC Y3E 085 ...
X
085 - 85 - 95 40 - 2 x 760 - - - 1520
105 - 105 - 115 60 - 2 x 1000 - - - 2000
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
*
*
-
085
CB ... M
Y=X=
Y=X=
VC
VC
45
Y3E
Y3E
J2 (mm)
max. 12
1)
C (mm)
03 / 04 / 07
30
3)
4)
2) 2)
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
3)
4)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the nozzles!
In case of lack of space use next larger manifold
type.
for X < 40 mm
for X 40 mm
Length
code
Heater zones power (Watt)
3-port-Y-manifold
3-port-Y-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
13 / 44
C P
T A
VC Y3E 125 ...
125 - 125 - 135 80 - 2 x 1200 - - - 2400
145 - 145 - 155 100 - 2 x 1260 - - - 2520
165 - 165 - 175 120 - 2 x 1176 - - - 2352
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
-
125
CB ... M
Y=X=
Y=X=
VC
VC
85
Y3E
Y3E
J2 (mm)
max. 12
1)
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
2) 2)
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
3-port-Y-manifold
3-port-Y-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
14 / 44
C P
T A
X
VC Y3E 180 ...
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
-
180
CB ... M
Y=X=
Y=X=
VC
VC
145
Y3E
Y3E
1)
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
180 - 180 - 190 140 - 2 x 560 2 x 560 2 x 560 - 3360
200 - 200 - 210 160 - 2 x 640 2 x 640 2 x 640 - 3840
220 - 220 - 230 180 - 2 x 720 2 x 720 2 x 720 - 4320
240 - 240 - 250 200 - 2 x 560 2 x 560 2 x 560 - 3360
260 - 260 - 270 220 - 2 x 880 2 x 880 2 x 880 - 5280
280 - 280 - 290 240 - 2 x 672 2 x 672 2 x 672 - 4032
300 - 300 - 310 260 - 2 x 1040 2 x 1040 2 x 1040 - 6240
320 - 320 - 330 280 - 2 x 1150 2 x 1150 2 x 1150 - 6900
340 - 340 - 350 300 - 2 x 1200 2 x 1200 2 x 1200 - 7200
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
3-port-Y-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
3-port-Y-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
15 / 44
C P
T A
VC I4E 210 ...
210 210 - 230 - 40 - 2 x 760 - - - 1520
240 240 - 260 - 50 - 2 x 880 - - - 1760
270 270 - 290 - 60 - 2 x 1000 - - - 2000
300 300 - 320 - 70 - 2 x 1150 - - - 2300
1 2 3 4 1...4
Y
(mm)
X
(mm)
±5
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
Lx2
Lx
X X X
*
*
I4E
I4E
-
210
CB ... M
Y=X=
Y=X=
VC
VC
45
1)
2) 2)
J2 (mm)
max. 12
C (mm)
03 / 04 / 07
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-I-manifold
replaced by second dowel
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
16 / 44
C P
T A
Lx2
Lx
X X X
VC I4E 330 ...
1 2 3 4 1...4
Y
(mm)
X
(mm)
±5
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
*
*
-
330
CB ... M
Y=X=
Y=X=
VC
VC
85
I4E
I4E
1)
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
03 / 04 / 07 12
1203 04 07
330 330 - 350 - 80 - 2 x 600 2 x 600 - - 2400
360 360 - 380 - 90 - 2 x 640 2 x 640 - - 2560
390 390 - 410 - 100 - 2 x 720 2 x 720 - - 2880
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-I-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-I-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
17 / 44
C P
T A
VC H4E 160 146 ...
160 146 160 146 180 166 40 40 2 x 1200 - - - 2400
160 166 160 166 180 186 40 50 2 x 1000 - - - 2000
Lx2
Lx
X X
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
*
*
H4E
H4E
45
160 146
CB ... M
Y=X=
Y=X=
VC
VC
45
1)
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
03 / 04 / 07 12
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-H-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
18 / 44
C P
T A
VC H4E 160 186 ...
Lx2
Lx
X X
*
*
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
65
160 186
CB ... M
Y=X=
Y=X=
VC
VC
45
H4E
H4E
1)
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
160 186 160 186 180 206 40 60 2 x 1150 - - - 2300
200 186 200 186 220 206 60 60 2 x 1204 - - - 2408
160 206 160 206 180 226 40 70 2 x 1036 - - - 2072
200 206 200 206 220 226 60 70 2 x 1260 - - - 2520
160 226 160 226 180 246 40 80 2 x 1240 - - - 2480
200 226 200 226 226 246 60 80 2 x 1310 - - - 2620
240 226 240 226 260 246 80 80 2 x 1400 - - - 2800
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-H-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
19 / 44
C P
T A
VC H4E 160 246 ...
Lx2
Lx
X X
*
*
95
160 246
CB ... M
Y=X=
Y=X=
VC
VC
45
H4E
H4E
1)
J2 (mm)
max. 12
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
4-port-H-manifold
Plate bolts:
M10 - 12.9 (2x per nozzle)
20 / 44
C P
T A
1 2 3 4 1...4
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
VC H4E 160 246 ...
160 246 160 246 180 266 40 90 2 x 720 2 x 720 - - 2880
200 246 200 246 220 266 60 90 2 x 880 2 x 880 - - 3520
240 246 240 246 260 266 80 90 2 x 1040 2 x 1040 - - 4160
160 266 160 266 180 286 40 100 2 x 760 2 x 760 - - 3040
200 266 200 266 220 286 60 100 2 x 644 2 x 644 - - 2576
240 266 240 266 260 286 80 100 2 x 756 2 x 756 - - 3024
280 266 280 266 300 286 100 100 2 x 1200 2 x 1200 - - 4800
160 286 160 286 180 306 40 110 2 x 560 2 x 560 - - 2240
200 286 200 286 220 306 60 110 2 x 672 2 x 672 - - 2688
240 286 240 286 260 306 80 110 2 x 1150 2 x 1150 - - 4600
280 286 280 286 300 306 100 110 2 x 1280 2 x 1280 - - 5120
160 306 160 306 180 326 40 120 2 x 588 2 x 588 - - 2352
200 306 200 306 220 326 60 120 2 x 1000 2 x 1000 - - 4000
240 306 240 306 260 326 80 120 2 x 1000 2 x 1000 - - 4000
280 306 280 306 300 326 100 120 2 x 1000 2 x 1000 - - 4000
320 306 320 306 340 326 120 120 2 x 1036 2 x 1036 - - 4144
160 326 160 326 180 346 40 130 2 x 880 2 x 880 - - 3520
200 326 200 326 220 346 60 130 2 x 1040 2 x 1040 - - 4160
240 326 240 326 260 346 80 130 2 x 1200 2 x 1200 - - 4800
280 326 280 326 300 346 100 130 2 x 1360 2 x 1360 - - 5440
320 326 320 326 340 346 120 130 2 x 1064 2 x 1064 - - 4256
160 346 160 346 180 366 40 140 2 x 644 2 x 644 - - 2576
200 346 200 346 220 366 60 140 2 x 756 2 x 756 - - 3024
240 346 240 346 260 366 80 140 2 x 1200 2 x 1200 - - 4800
280 346 280 346 300 366 100 140 2 x 1150 2 x 1150 - - 4600
320 346 320 346 340 366 120 140 2 x 1240 2 x 1240 - - 4960
360 346 360 346 380 366 140 140 2 x 1204 2 x 1204 - - 4816
160 366 160 366 180 386 40 150 2 x 672 2 x 672 - - 2688
200 366 200 366 220 386 60 150 2 x 1150 2 x 1150 - - 4600
240 366 240 366 260 386 80 150 2 x 1280 2 x 1280 - - 5120
280 366 280 366 300 386 100 150 2 x 1260 2 x 1260 - - 5040
320 366 320 366 340 386 120 150 2 x 1120 2 x 1120 - - 4480
360 366 360 366 380 386 140 150 2 x 1232 2 x 1232 - - 4928
160 386 160 386 180 406 40 160 2 x 1000 2 x 1000 - - 4000
200 386 200 386 220 406 60 160 2 x 1000 2 x 1000 - - 4000
240 386 240 386 260 406 80 160 2 x 1000 2 x 1000 - - 4000
280 386 280 386 300 406 100 160 2 x 1036 2 x 1036 - - 4144
320 386 320 386 340 406 120 160 2 x 1148 2 x 1148 - - 4592
360 386 360 386 380 406 140 160 2 x 1260 2 x 1260 - - 5040
400 386 400 386 420 406 160 160 2 x 1372 2 x 1372 - - 5488
Y
(mm)
±5
X
(mm)
±10
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Length
code
Heater zones power (Watt)
4-port-H-manifold
21 / 44
C P
T A
VC H4E 160 406 ...
Lx
X
J1
Lx2
Lx
X X
*
*
175
160 406
CB ... M
Y=X=
Y=X=
VC
VC
45
H4E
H4E
1)
J2 (mm)
max. 12
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
4-port-H-manifold
Plate bolts:
M10 - 12.9 (2x per nozzle)
22 / 44
C P
T A
VC H4E 160 406 ...
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
160 406 160 406 180 426 40 170 2 x 720 2 x 720 2 x 560 - 2880
200 406 200 406 220 426 60 170 2 x 880 2 x 880 2 x 560 - 3520
240 406 240 406 260 426 80 170 2 x 1040 2 x 1040 2 x 560 - 4160
280 406 280 406 300 426 100 170 2 x 1200 2 x 1200 2 x 560 - 4800
160 426 160 426 180 446 40 180 2 x 760 2 x 760 2 x 560 - 3040
200 426 200 426 220 446 60 180 2 x 644 2 x 644 2 x 560 - 2576
240 426 240 426 260 446 80 180 2 x 756 2 x 756 2 x 560 - 3024
280 426 280 426 300 446 100 180 2 x 1200 2 x 1200 2 x 560 - 4800
160 446 160 446 180 466 40 190 2 x 560 2 x 560 2 x 560 - 2240
200 446 200 446 220 466 60 190 2 x 672 2 x 672 2 x 560 - 2688
240 446 240 446 260 466 80 190 2 x 1150 2 x 1150 2 x 560 - 4600
280 446 280 446 300 466 100 190 2 x 1280 2 x 1280 2 x 560 - 5120
160 466 160 466 180 486 40 200 2 x 588 2 x 588 2 x 560 - 2352
200 466 200 466 220 486 60 200 2 x 1000 2 x 1000 2 x 560 - 4000
240 466 240 466 260 486 80 200 2 x 1000 2 x 1000 2 x 560 - 4000
280 466 280 466 300 486 100 200 2 x 1000 2 x 1000 2 x 560 - 4000
160 486 160 486 180 506 40 210 2 x 880 2 x 880 2 x 560 - 3520
200 486 200 486 220 506 60 210 2 x 1040 2 x 1040 2 x 560 - 4160
240 486 240 486 260 506 80 210 2 x 1200 2 x 1200 2 x 560 - 4800
280 486 280 486 300 506 100 210 2 x 1360 2 x 1360 2 x 560 - 5440
160 506 160 506 180 526 40 220 2 x 644 2 x 644 2 x 560 - 2576
200 506 200 506 220 526 60 220 2 x 756 2 x 756 2 x 560 - 3024
240 506 240 506 260 526 80 220 2 x 1200 2 x 1200 2 x 560 - 4800
280 506 280 506 300 526 100 220 2 x 1150 2 x 1150 2 x 560 - 4600
160 526 160 526 180 546 40 230 2 x 672 2 x 672 2 x 560 - 2688
200 526 200 526 220 546 60 230 2 x 1150 2 x 1150 2 x 560 - 4600
240 526 240 526 260 546 80 230 2 x 1280 2 x 1280 2 x 560 - 5120
280 526 280 526 300 546 100 230 2 x 1260 2 x 1260 2 x 560 - 5040
160 546 160 546 180 566 40 240 2 x 1000 2 x 1000 2 x 560 - 4000
200 546 200 546 220 566 60 240 2 x 1000 2 x 1000 2 x 560 - 4000
240 546 240 546 260 566 80 240 2 x 1000 2 x 1000 2 x 560 - 4000
280 546 280 546 300 566 100 240 2 x 1036 2 x 1036 2 x 560 - 4144
160 566 160 566 180 586 40 250 2 x 1040 2 x 1040 2 x 560 - 4160
200 566 200 566 220 586 60 250 2 x 1200 2 x 1200 2 x 560 - 4800
240 566 240 566 260 586 80 250 2 x 1360 2 x 1360 2 x 560 - 5440
280 566 280 566 300 586 100 250 2 x 1064 2 x 1064 2 x 560 - 4256
160 586 160 586 180 606 40 260 2 x 756 2 x 756 2 x 560 - 3024
200 586 200 586 220 606 60 260 2 x 1200 2 x 1200 2 x 560 - 4800
240 586 240 586 260 606 80 260 2 x 1150 2 x 1150 2 x 560 - 4600
280 586 280 586 300 606 100 260 2 x 1240 2 x 1240 2 x 560 - 4960
160 606 160 606 180 626 40 270 2 x 1150 2 x 1150 2 x 560 - 4600
200 606 200 606 220 626 60 270 2 x 1280 2 x 1280 2 x 560 - 5120
240 606 240 606 260 626 80 270 2 x 1260 2 x 1260 2 x 560 - 5040
280 606 280 606 300 626 100 270 2 x 1120 2 x 1120 2 x 560 - 4480
160 626 160 626 180 646 40 280 2 x 1000 2 x 1000 2 x 560 - 4000
200 626 200 626 220 646 60 280 2 x 1000 2 x 1000 2 x 560 - 4000
240 626 240 626 260 646 80 280 2 x 1036 2 x 1036 2 x 560 - 4144
280 626 280 626 300 646 100 280 2 x 1148 2 x 1148 2 x 560 - 4592
160 646 160 646 180 666 40 290 2 x 1200 2 x 1200 2 x 560 - 4800
200 646 200 646 220 666 60 290 2 x 1360 2 x 1360 2 x 560 - 5440
240 646 240 646 260 666 80 290 2 x 1064 2 x 1064 2 x 560 - 4256
280 646 280 646 300 666 100 290 2 x 1176 2 x 1176 2 x 560 - 4704
160 666 160 666 180 686 40 300 2 x 1200 2 x 1200 2 x 560 - 4800
200 666 200 666 220 686 60 300 2 x 1150 2 x 1150 2 x 560 - 4600
240 666 240 666 260 686 80 300 2 x 1240 2 x 1240 2 x 560 - 4960
280 666 280 666 300 686 100 300 2 x 1204 2 x 1204 2 x 560 - 4816
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Length
code
Heater zones power (Watt)
4-port-H-manifold
23 / 44
C P
T A
VC X4E 202 ...
Lx
X X
Lx2
Xp
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
7±
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
202 202 - 222 - 60 - 2 x 1240 - - - 2480
242 242 - 262 - 80 - 2 x 1400 - - - 2800
X4E
X4E
-
202
CB ... M
Y=X=
Y=X=
VC
VC
65
1)
2) 2)
J2 (mm)
max. 12
30
128
69
40
157
83
C (mm)
Xp (mm)
Xw (mm)
Lb (mm)
03 / 04 / 07
202
202
12
242
242
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
for Lx =
for Lx =
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
24 / 44
C P
T A
VC X4E 282 ...
1 2 3 4 1...4
Y
(mm)
X
(mm)
7±
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
Lx
X X
Lx2
Xp
*
*
-
282
CB ... M
Y=X=
Y=X=
VC
VC
105
X4E
X4E
1)
282 282 - 302 - 100 - 2 x 1000 2 x 1000 - - 4000
322 322 - 342 - 120 - 2 x 1150 2 x 1150 - - 4600
2) 2)
J2 (mm)
max. 12
30
185
97
40
213
111
C (mm)
Xp (mm)
Xw (mm)
Lb (mm)
03 / 04 / 07
282
282
12
322
322
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
for Lx =
for Lx =
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
25 / 44
C P
T A
VC X4E 362 ...
Lx
X X
Lx2
Xp
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
7±
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
-
362
CB ... M
Y=X=
Y=X=
VC
VC
145
X4E
X4E
1)
362 362 - 382 - 140 - 2 x 760 2 x 760 2 x 760 2 x 760 6080
402 402 - 422 - 160 - 2 x 880 2 x 880 2 x 880 2 x 880 7040
442 442 - 462 - 180 - 2 x 1000 2 x 1000 2 x 1000 2 x 1000 8000
482 482 - 502 - 200 - 2 x 756 2 x 756 2 x 756 2 x 756 6048
522 522 - 542 - 220 - 2 x 1200 2 x 1200 2 x 1200 2 x 1200 9600
562 562 - 582 - 240 - 2 x 1000 2 x 1000 2 x 1000 2 x 1000 8000
602 602 - 622 - 260 - 2 x 1260 2 x 1260 2 x 1260 2 x 1260 10080
642 642 - 662 - 280 - 2 x 1240 2 x 1240 2 x 1240 2 x 1240 9920
682 682 - 702 - 300 - 2 x 1148 2 x 1148 2 x 1148 2 x 1148 9184
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
Xp (mm)
Xw (mm)
Lb (mm)
03 / 04 / 07 12
362
362
402
402
442
442
482
482
522
522
562
562
602
602
642
642
682
682
242
152
270
176
298
190
326
204
355
218
383
232
411
246
439
260
468
275
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
for Lx =
for Lx =
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
4-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
26 / 44
C P
T A
VC XSE
X X
*
*
120 CB ... M
Y=X=
Y=X=
VC
VC
170
XSE
XSE
1)
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
170..
..300
120..
..300
2) 2)
J2 (mm)
max. 12
30 40
C (mm)
Lb (mm)
03 / 04 / 07 12
ABK ABL/ABTABM
34.5 40.537.5
2 x
max.
1400 2 x
max.
1400 2 x
max.
1400 2 x
max.
1400
max.
11200
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
4-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
Dimensions on request
4-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
27 / 44
C P
T A
VC Y6E 232 ...
Lx2
Xp
Lx
X X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
232 232 152 252 172 80 - 2 x 1036 - - - 2072
272 272 172 292 192 100 - 2 x 1400 - - - 2800
312 312 192 332 212 120 - 2 x 1400 - - - 2800
Y6E
Y6E
-
232
CB ... M
Y=X=
Y=X=
VC
VC
80
1)
2) 2)
J2 (mm)
max. 12
30
91.5 101.5
40
111.5
C (mm)
Xp (mm)
Lb (mm)
03 / 04 / 07
232 272
12
312
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
6-port-Y-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
for Lx =
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
6-port-Y-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
28 / 44
C P
T A
VC Y6E 352 ...
Lx2
Xp
Lx
X X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
352 352 212 372 232 140 - 2 x 1150 - - - 2300
392 392 232 412 252 160 - 2 x 1120 - - - 2240
432 432 252 452 272 180 - 2 x 1260 - - - 2520
472 472 272 492 292 200 - 2 x 1400 - - - 2800
-
352
CB ... M
Y=X=
Y=X=
VC
VC
140
Y6E
Y6E
1)
2) 2)
J2 (mm)
max. 12
30
138.5 148.5
40
158.5 168.5
C (mm)
Xp (mm)
Lb (mm)
03 / 04 / 07
352 392
12
432 472
ABK ABL/ABTABM
34.5 40.537.5
1203 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
6-port-Y-manifold
2)
Nozzle size manifold can be used with
for nozzle size for nozzle size
for Lx =
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
6-port-Y-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
29 / 44
C P
T A
VC H6E 160 146 ...
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
Lx
X X
Lx2
*
*
160 146 160 146 180 166 40 40 2 x 1200 - - - 2400
160 166 160 166 180 186 40 50 2 x 1000 - - - 2000
H6E
H6E
45
160 146
CB ... M
Y=X=
Y=X=
VC
VC
45
1)
2) 2)
J2 (mm)
max. 12
30
C (mm)
03 / 04 / 07
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
6-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
6-port-H-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
30 / 44
C P
T A
VC H6E 160 186 ...
Lx2
Lx
X X
*
*
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
160 186 160 186 180 206 40 60 2 x 1150 - - - 2300
200 186 200 186 220 206 60 60 2 x 1204 - - - 2408
160 206 160 206 180 226 40 70 2 x 1036 - - - 2072
200 206 200 206 220 226 60 70 2 x 1260 - - - 2520
160 226 160 226 180 246 40 80 2 x 1240 - - - 2480
200 226 200 226 220 246 60 80 2 x 1310 - - - 2620
240 226 240 226 260 246 80 80 2 x 1400 - - - 2800
65
160 186
CB ... M
Y=X=
Y=X=
VC
VC
45
H6E
H6E
1)
2) 2)
J2 (mm)
max. 12
30
C (mm)
Lb (mm)
03 / 04 / 07
ABK ABL/ABTABM
34.5 40.537.5
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
6-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
6-port-H-manifold
Plate bolts:
M10 - 12.9 (2x per nozzle)
31 / 44
C P
T A
VC H6E 160 246 ...
Lx2
Lx
X X
*
*
95
160 246
CB ... M
Y=X=
Y=X=
VC
VC
45
H6E
H6E
1)
J2 (mm)
max. 12
30
C (mm)
Lb (mm)
03 / 04 / 07
ABK ABL/ABTABM
34.5 40.537.5
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
6-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
6-port-H-manifold
Plate bolts:
M10 - 12.9 (2x per nozzle)
32 / 44
C P
T A
VC H6E 160 246 ...
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
160 246 160 246 180 266 40 90 2 x 720 2 x 720 - - 2880
200 246 200 246 220 266 60 90 2 x 880 2 x 880 - - 3520
240 246 240 246 260 266 80 90 2 x 1040 2 x 1040 - - 4160
160 266 160 266 180 286 40 100 2 x 760 2 x 760 - - 3040
200 266 200 266 220 286 60 100 2 x 644 2 x 644 - - 2576
240 266 240 266 260 286 80 100 2 x 756 2 x 756 - - 3024
280 266 280 266 300 286 100 100 2 x 1200 2 x 1200 - - 4800
160 286 160 286 180 306 40 110 2 x 560 2 x 560 - - 2240
200 286 200 286 220 306 60 110 2 x 672 2 x 672 - - 2688
240 286 240 286 260 306 80 110 2 x 1150 2 x 1150 - - 4600
280 286 280 286 300 306 100 110 2 x 1280 2 x 1280 - - 5120
160 306 160 306 180 326 40 120 2 x 588 2 x 588 - - 2352
200 306 200 306 220 326 60 120 2 x 1000 2 x 1000 - - 4000
240 306 240 306 260 326 80 120 2 x 1000 2 x 1000 - - 4000
280 306 280 306 300 326 100 120 2 x 1000 2 x 1000 - - 4000
320 306 320 306 340 326 120 120 2 x 1036 2 x 1036 - - 4144
160 326 160 326 180 346 40 130 2 x 880 2 x 880 - - 3520
200 326 200 326 220 346 60 130 2 x 1040 2 x 1040 - - 4160
240 326 240 326 260 346 80 130 2 x 1200 2 x 1200 - - 4800
280 326 280 326 300 346 100 130 2 x 1360 2 x 1360 - - 5440
320 326 320 326 340 346 120 130 2 x 1064 2 x 1064 - - 4256
160 346 160 346 180 366 40 140 2 x 644 2 x 644 - - 2576
200 346 200 346 220 366 60 140 2 x 756 2 x 756 - - 3024
240 346 240 346 260 366 80 140 2 x 1200 2 x 1200 - - 4800
280 346 280 346 300 366 100 140 2 x 1150 2 x 1150 - - 4600
320 346 320 346 340 366 120 140 2 x 1240 2 x 1240 - - 4960
360 346 360 346 380 366 140 140 2 x 1204 2 x 1204 - - 4816
160 366 160 366 180 386 40 150 2 x 672 2 x 672 - - 2688
200 366 200 366 220 386 60 150 2 x 1150 2 x 1150 - - 4600
240 366 240 366 260 386 80 150 2 x 1280 2 x 1280 - - 5120
280 366 280 366 300 386 100 150 2 x 1260 2 x 1260 - - 5040
320 366 320 366 340 386 120 150 2 x 1120 2 x 1120 - - 4480
360 366 360 366 380 386 140 150 2 x 1232 2 x 1232 - - 4928
160 386 160 386 180 406 40 160 2 x 1000 2 x 1000 - - 4000
200 386 200 386 220 406 60 160 2 x 1000 2 x 1000 - - 4000
240 386 240 386 260 406 80 160 2 x 1000 2 x 1000 - - 4000
280 386 280 386 300 406 100 160 2 x 1036 2 x 1036 - - 4144
320 386 320 386 340 406 120 160 2 x 1148 2 x 1148 - - 4592
360 386 360 386 380 406 140 160 2 x 1260 2 x 1260 - - 5040
400 386 400 386 420 406 160 160 2 x 1372 2 x 1372 - - 5488
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Length
code
Heater zones power (Watt)
6-port-H-manifold
33 / 44
C P
T A
VC H6E 160 406 ...
Lx2
Lx
X X
*
*
175
160 406
CB ... M
Y=X=
Y=X=
VC
VC
45
H6E
H6E
1)
J2 (mm)
max. 12
30
C (mm)
Lb (mm)
03 / 04 / 07
ABK ABL/ABTABM
34.5 40.537.5
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
6-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
6-port-H-manifold
Plate bolts:
M10 - 12.9 (2x per nozzle)
34 / 44
C P
T A
VC H6E 160 406 ...
1 2 3 4 1...4
Y
(mm)
±5
X
(mm)
±10
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
160 406 160 406 180 426 40 170 2 x 720 2 x 720 2 x 560 - 2880
200 406 200 406 220 426 60 170 2 x 880 2 x 880 2 x 560 - 3520
240 406 240 406 260 426 80 170 2 x 1040 2 x 1040 2 x 560 - 4160
280 406 280 406 300 426 100 170 2 x 1200 2 x 1200 2 x 560 - 4800
160 426 160 426 180 446 40 180 2 x 760 2 x 760 2 x 560 - 3040
200 426 200 426 220 446 60 180 2 x 644 2 x 644 2 x 560 - 2576
240 426 240 426 260 446 80 180 2 x 756 2 x 756 2 x 560 - 3024
280 426 280 426 300 446 100 180 2 x 1200 2 x 1200 2 x 560 - 4800
160 446 160 446 180 466 40 190 2 x 560 2 x 560 2 x 560 - 2240
200 446 200 446 220 466 60 190 2 x 672 2 x 672 2 x 560 - 2688
240 446 240 446 260 466 80 190 2 x 1150 2 x 1150 2 x 560 - 4600
280 446 280 446 300 466 100 190 2 x 1280 2 x 1280 2 x 560 - 5120
160 466 160 466 180 486 40 200 2 x 588 2 x 588 2 x 560 - 2352
200 466 200 466 220 486 60 200 2 x 1000 2 x 1000 2 x 560 - 4000
240 466 240 466 260 486 80 200 2 x 1000 2 x 1000 2 x 560 - 4000
280 466 280 466 300 486 100 200 2 x 1000 2 x 1000 2 x 560 - 4000
160 486 160 486 180 506 40 210 2 x 880 2 x 880 2 x 560 - 3520
200 486 200 486 220 506 60 210 2 x 1040 2 x 1040 2 x 560 - 4160
240 486 240 486 260 506 80 210 2 x 1200 2 x 1200 2 x 560 - 4800
280 486 280 486 300 506 100 210 2 x 1360 2 x 1360 2 x 560 - 5440
160 506 160 506 180 526 40 220 2 x 644 2 x 644 2 x 560 - 2576
200 506 200 506 220 526 60 220 2 x 756 2 x 756 2 x 560 - 3024
240 506 240 506 260 526 80 220 2 x 1200 2 x 1200 2 x 560 - 4800
280 506 280 506 300 526 100 220 2 x 1150 2 x 1150 2 x 560 - 4600
160 526 160 526 180 546 40 230 2 x 672 2 x 672 2 x 560 - 2688
200 526 200 526 220 546 60 230 2 x 1150 2 x 1150 2 x 560 - 4600
240 526 240 526 260 546 80 230 2 x 1280 2 x 1280 2 x 560 - 5120
280 526 280 526 300 546 100 230 2 x 1260 2 x 1260 2 x 560 - 5040
160 546 160 546 180 566 40 240 2 x 1000 2 x 1000 2 x 560 - 4000
200 546 200 546 220 566 60 240 2 x 1000 2 x 1000 2 x 560 - 4000
240 546 240 546 260 566 80 240 2 x 1000 2 x 1000 2 x 560 - 4000
280 546 280 546 300 566 100 240 2 x 1036 2 x 1036 2 x 560 - 4144
160 566 160 566 180 586 40 250 2 x 1040 2 x 1040 2 x 560 - 4160
200 566 200 566 220 586 60 250 2 x 1200 2 x 1200 2 x 560 - 4800
240 566 240 566 260 586 80 250 2 x 1360 2 x 1360 2 x 560 - 5440
280 566 280 566 300 586 100 250 2 x 1064 2 x 1064 2 x 560 - 4256
160 586 160 586 180 606 40 260 2 x 756 2 x 756 2 x 560 - 3024
200 586 200 586 220 606 60 260 2 x 1200 2 x 1200 2 x 560 - 4800
240 586 240 586 260 606 80 260 2 x 1150 2 x 1150 2 x 560 - 4600
280 586 280 586 300 606 100 260 2 x 1240 2 x 1240 2 x 560 - 4960
160 606 160 606 180 626 40 270 2 x 1150 2 x 1150 2 x 560 - 4600
200 606 200 606 220 626 60 270 2 x 1280 2 x 1280 2 x 560 - 5120
240 606 240 606 260 626 80 270 2 x 1260 2 x 1260 2 x 560 - 5040
280 606 280 606 300 626 100 270 2 x 1120 2 x 1120 2 x 560 - 4480
160 626 160 626 180 646 40 280 2 x 1000 2 x 1000 2 x 560 - 4000
200 626 200 626 220 646 60 280 2 x 1000 2 x 1000 2 x 560 - 4000
240 626 240 626 260 646 80 280 2 x 1036 2 x 1036 2 x 560 - 4144
280 626 280 626 300 646 100 280 2 x 1148 2 x 1148 2 x 560 - 4592
160 646 160 646 180 666 40 290 2 x 1200 2 x 1200 2 x 560 - 4800
200 646 200 646 220 666 60 290 2 x 1360 2 x 1360 2 x 560 - 5440
240 646 240 646 260 666 80 290 2 x 1064 2 x 1064 2 x 560 - 4256
280 646 280 646 300 666 100 290 2 x 1176 2 x 1176 2 x 560 - 4704
160 666 160 666 180 686 40 300 2 x 1200 2 x 1200 2 x 560 - 4800
200 666 200 666 220 686 60 300 2 x 1150 2 x 1150 2 x 560 - 4600
240 666 240 666 260 686 80 300 2 x 1240 2 x 1240 2 x 560 - 4960
280 666 280 666 300 686 100 300 2 x 1204 2 x 1204 2 x 560 - 4816
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Length
code
Heater zones power (Watt)
6-port-H-manifold
35 / 44
C P
T A
VC H8E 168
Lx
X X X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±2.5
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
168 168 90 - - 30.5 - 2 x 720 - - - 1440
H8E
H8E
-
168
04 C01
Y=X=
Y=X=
VC
VC
33
1)
2) 2)
J2 (mm)
max. 12
C (mm)
03 / 04
03 04
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
8-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
replaced by second dowel
Length
code
Heater zones power (Watt)
8-port-H-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
36 / 44
C P
T A
VC H8E 188 ...
Lx
Lx2
X X X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
-
188
CB ... M
Y=X=
Y=X=
VC
VC
40
H8E
H8E
188 188 98 208 118
36.5
±3.5
- 2 x 588 - - - 1176
218 218 100 238 128
45
±5
- 2 x 756 - - - 1512
1)
2) 2)
J2 (mm)
max. 12
C (mm)
03 / 04 / 07
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
8-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
replaced by second dowel
Length
code
Heater zones power (Watt)
8-port-H-manifold
Plate bolts:
M10 - 12.9
(2x per nozzle)
37 / 44
C P
T A
VC H8E 248 ...
Lx
Lx2
X X X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
±5
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
248 248 118 268 138 55 - 2 x 1280 - - - 2560
278 278 128 298 148 65 - 2 x 1260 - - - 2520
-
248
CB ... M
Y=X=
Y=X=
VC
VC
60
H8E
H8E
1)
2) 2)
J2 (mm)
max. 12
C (mm)
03 / 04 / 07
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
8-port-H-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
replaced by second dowel
Length
code
Heater zones power (Watt)
8-port-H-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
38 / 44
C P
T A
VC Y12E 240 ...
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
Y12E
Y12E
-
240
CB ... M
Y=X=
Y=X=
VC
VC
60
2) 2)
240 240 180 260 200 60 - 2 x 1040 2 x 1040 - - 4160
270 270 200 290 220 70 - 2 x 1000 2 x 1000 - - 4000
J2 (mm)
max. 12
30
C (mm)
03 / 04 / 07
03 04 07
Lx
Lx2
X X X
*
*
1)
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
12-port-Y-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
12-port-Y-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
39 / 44
C P
T A
VC X16E 236 ...
Lx
Lx2
X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
X16E
X16E
-
236
CB ... M
Y=X=
Y=X=
VC
VC
60
1)
2) 2)
J2 (mm)
max. 12
30
C (mm)
03 / 04 / 07
236 236 - 256 - 60 - 2 x 1000 2 x 1000 - - 4000
266 266 - 286 - 70 - 2 x 1036 2 x 1036 - - 4144
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
16-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
16-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
40 / 44
C P
T A
VC X24E 356 ...
Lx2
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
X24E
X24E
-
356
CB ... M
Y=X=
Y=X=
VC
VC
60
1)
2) 2)
J2 (mm)
max. 12
30
C (mm)
03 / 04 / 07
356 356 236 386 266 60 - 2 x 1000 2 x 1000 2 x 1000 - 6000
406 406 266 436 296 70 - 2 x 1036 2 x 1036 2 x 1036 - 6216
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
24-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
24-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
41 / 44
C P
T A
VC X32E 476 ...
Lx
Lx2
X
*
*
1 2 3 4 1...4
Y
(mm)
X
(mm)
Ly2
(mm)
Lx2
(mm)
Ly
(mm)
Lx
(mm)
X32E
X32E
-
476
CB ... M
Y=X=
Y=X=
VC
VC
60
1)
2) 2)
J2 (mm)
max. 12
30
C (mm)
03 / 04 / 07
476 476 236 506 266 60 - 2 x 1000 2 x 1000 2 x 1000 2 x 1000 8000
546 546 266 576 296 70 - 2 x 1036 2 x 1036 2 x 1036 2 x 1036 8288
03 04 07
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
You can configure your manifold here
1. Complete the manifold description
2. Selection of variables
Series & Type
Nozzle series
Length code
Example and explanations
Series Position in manifold
length chart
Series & Type Length code
Type
requested pitch
dimensions
Nozzle series the manifold
will be combined with
32-port-X-manifold
2)
Nozzle size manifold can be used with
for nozzle size
*The values of these dimensions depend on the
selected nozzle series. They can be found in the
Synventive Hot Runner Guide.
1)
2)
Hardened insert recommended; is not supplied
with the hot runner system.
Provide enough installation space for the
nozzles! In case of lack of space use next larger
manifold type.
Length
code
Heater zones power (Watt)
32-port-X-manifold
Plate bolts: M10 - 12.9 (2x per nozzle)
42 / 44
C P
T A
VC
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Manifolds in customised shape
Manifolds in customised shape are designed
and made according to the customer’s
specification by using components of the
selected manifold series.
Shown on the right there is a manifold in
customised shape which has been designed
by using components of series .VC
Series
43 / 44
C P
T A
VC
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
Series
Bridge manifolds
Bridge manifolds make it possible to combine
several manifolds to one feed system. They
are are designed and made according to the
customer’s specification by using components
of the selected manifold series.
Shown on the right there is a bridge manifold
which has been designed by using
components of series .VC
44 / 44
C P
T A
For design and application information,
see the Synventive Hot Runner Guide.
2006-08-01 - All rights reserved. Errors and omissions excepted.
For a specific application, please consult Synventive.
Illustrations simplified, schematically drawn and not to scale.
C P
T A
AU - Australia +61 3 9886 3475 [email protected]
BR - Brasil - Brazil +55 (0)11 6191 3433 [email protected]
CA - Canada +1 514-421-8963
+1 604-943-7702
CN - People's Republic of China +86 512 62838870
+86 755 82315175
CZ - Czech Rebpublic +420 326 992 038 [email protected]
DE - Germany +49 (0) 6251 9332-0 [email protected]
DK - Denmark +45 33931629 [email protected]
ES - Spain +34 93 565 15 00 [email protected]
FI - Finland +358(0)207 519 600 [email protected]
FR - France +33 (0) 474991600 [email protected]
GB - Great Britain +44 (0) 1527577417 [email protected]
IL - Israel +972-3-7325446 [email protected]
IN - India +91 80 2558 0024 [email protected]
IT - Italy +39 0266505373 [email protected]
JP - Japan + 81 45 472 1239 [email protected]
NL - The Netherlands +31 (0) 786738282 [email protected]
PL - Poland +48 (0) 52 323 12 00 [email protected]
PT - Portugal +351 244829790 [email protected]
SG - Singapore +65 65368093 [email protected]
SK - Slovak Republic +421 (0)2 63 82 92 48 [email protected]
US - United States of America +1 800.367.5662
+1 248.457.0761