C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to...

46
37 C Company P Products A Application T Technology Hot Runner Manifolds Series VC

Transcript of C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to...

Page 1: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

C P

T A

37

CCompany

PProducts

A

Application

T

Technology

Hot Runner Manifolds

Series VC

Page 2: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

M

A

Z

B

C

E

J2

1)

2)

2)

12...20

11.5...28

0...0.16

30 / 40

15...50

Ø29...Ø69

Ø61 / Ø74

Ø72 / Ø85

3

4

5

6

1

2

8

7

A

B

Z

C

E

De1

De2

De3

37 mm

max. Ø12 mm

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Hardened insert recommended; is not supplied

with the hot runner system.

Values of these dimensions depend on the

selected nozzle or on the selected material. They

can be found in the Synventive Hot Runner Guide.

Hot runner manifolds

Product type

Hot runner manifold of series which are

characterised by the following dimensions:

The manifolds can be supplied

( )

ised .

The runners of standard manfiolds are

mechnanically balanced.

VC

in standard

shapes I, H, X, Y and in any realisable

custom shape

Series

M

J2

page no. of related data sheets

VC

Major dimensions (mm)

Components

3. Centre support

4. Support pillar

5. Dowel

6. Fastening screw

7. Support pad

8. Isolation bushing

1. Manifold block including heaters,

connections and thermocouple

2. Inlet bushing (including heater)

Melt flow components

Attached parts and accessories

Manifold cut out, right (above)

Manifold cut out, left (below)

Expansion gap

Height centre support

Height inlet bushing

Ø of contact inlet bushing

Ø of cut out inlet bushing

Ø of cut out isolation bushing

Thickness

Flow bore Ø

1)

2)

1 / 44

C P

T A

Page 3: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC

2

2

2

2

Lpl

AD

1

2

Jib1

(mm)

R

(mm)

AD

(°)

Dpl

(mm)

Lpl

(mm)

De2

(mm)

De1

(mm)

E

(mm)

Heater

power

(Watt)

E

A

X

Y

E

- - -

AD=

AD=

Dpl=

Dpl=

Lpl=

Lpl=

R=

R=

AB

AB L Y

16

K A 15 56 61 Ø8 max. 40 90 / 120 - - -

K X 15 56 61 Ø8 max. 40 90 / 120 - - -

K Y 15 56 61 Ø8 max. 40 90 / 120 - - -

M 06 001 35 29 - Ø6 max. 40 90 / 120 - - 180

M 08 001 35 29 - Ø8 max. 40 90 / 120 - - 180

L A 50 69 74 Ø8 max. 40 90 / 120 - - 630

L X 50 69 74 Ø8 max. 40 90 / 120 - - 630

L Y 50 69 74 Ø8 max. 40 90 / 120 - - 630

T A 50 69 74 Ø8 max. 40 90 / 120 max. Ø25 max. 30 630

T X 50 69 74 Ø8 max. 40 90 / 120 max. Ø25 max. 30 630

T Y 50 69 74 Ø8 max. 40 90 / 120 max. Ø25 max. 30 630

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Inlet bushings

Series

2. Selection of variables

Example and explanations

Type

Type

Here you can configure your inlet bushing

1. Complete the inlet bushing description

Inlet

bushing

long bushing

with Y shaped hole pattern

The hole pattern can be found in the manifold

data sheets.

For the inlet bushing type M the code for the hole

pattern is replaced by the code for flow channel

and version.

1)

2)

Inlet bushings which can be combined with

hot runner manifolds of series :VC

1. ABK ... / ABL ... / ABT ...

2. ABM ...

è

è

è

è

two styles:

three different hole patterns for

the attachment to the manifold

bore for decompression machine nozzle

possible

can be combined with isolation bushing

è

è

è

one length and always heated

two different flow bore-Ø possible

universal hole pattern for all manifold types

à

à

short and not heated

long and heated

Variables for precise part specification

from the drawings and tables shown here

1)

Type

Part code

Part code

2)

2 / 44

C P

T A

Page 4: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

B

M

3

VC

MCS 30 30 40

MSPL 09 20

MCS 30 30 50

MSPL 09 40

40

20

max. 26

max. 20

max. 36

max. 40

50

40

Lcs

(mm)

Lsp

(mm)

B

(mm)

B

(mm)

30 40

C (mm)

03 / 04 / 07 12

2)

2)

A

Z

B

C

1

4

6

2

5

1

5

6

2

3

4

Lcs

Lms

MS 30 15 t

ZAB 056 50

MS 30 30 t

ZAB 069 50

15

56 61 72 ABK/ABM

max. 15

max. 3030

69 74 85 ABL/ABT

Lms

(mm)

De1

(mm)

De2

(mm)

De3

(mm)

A

(mm)

2)

3)

3)

Lsp

De1

De2

De3

Z (mm)

0 ... 0.16

2)

1)

1. MCS 30 30 ...

2. MSPL ...

5. MS 30 ...

6. ZAB ...

4. DIN6325: 6 m6 x45 / 8 m6 x45

3. DIN 912: M6 / M8

M

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

1)

2)

3)

Hardened insert recommended; is not supplied

with the hot runner system.

Values of these dimensions depend on the

selected nozzle or on the selected material. They

can be found in the Synventive Hot Runner Guide.

Depending on manifold size and installation

space.

for

Centre

support

Support pad

Attached parts and accessories

Series

Attached parts and accessories for hot runner

manifolds of series :VC

for nozzle size for nozzle size

Support

pillar

Isolation

bushing

èFastening screws

èDowel

èSupport pads are only used when they are

needed e g when face fit manifold nozzles are

used.

3 / 44

C P

T A

Page 5: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

V1E

I2E

I3E Y3E

I4E X4E / XSEH4E

Y6E H6E

H8E

Y12E

X16E

X24E

X32E

1

2

3

4

6

8

12

16

24

32

I Y H X

1

2 3

VC

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Shape of manifold / runner layout inside manifold

No. of nozzles

Available manifold types

Customised manifolds Brigde manifolds

Manfold types and styles

Series

1. Manifolds in standard shape

2. Manifolds in customised shape

3. Bridge manifolds

Manifolds in standard shape

Shape of manifod resp. runner layout

inside the manfold

Number of nozzels fed by the manifold

Available manifold types: see right

are available in

different basic layouts, so called manifold

types, in order to put different standard gating

layouts into practice.

The different manifold types can be described

by the following features:

è

è

Manifolds in customised shape

according to the customer’s

specification by using

are designed

and made

components of the

selected manifold series.

Bridge manifolds make it possible to combine

several manifold to one feed system. They

are are designed and made according to the

customer’s specification by using components

of the selected manifold series.

page no. of related data sheets

4 / 44

C P

T A

Page 6: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

VC V1E 155 ...

Lx2

Lx

X

155 155 - 125 - 60 2 x 520 - - - 1040

175 175 - 145 - 80 2 x 600 - - - 1200

195 195 - 165 - 100 2 x 680 - - - 1360

*

*

J2 (mm)

max. 12

30 40

C (mm)

03 / 04 / 07 12

V1E

V1E

-

155

CB ... M

Y=X=

Y=X=

VC

VC

65

1)

2) 2)

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

1-port-I-manifold

1-port-I-manifold

Heater zones power (Watt)Length

code

for nozzle size for nozzle size

2)

Nozzle size manifold can be used with

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Plate bolts: M10 - 12.9 (2x per nozzle)

5 / 44

C P

T A

Page 7: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

205 205 - 175 - 120 - 2 x 720 - - - 1440

225 225 - 195 - 140 - 2 x 560 - - - 1120

245 245 - 215 - 160 - 2 x 880 - - - 1760

265 265 - 235 - 180 - 2 x 672 - - - 1344

285 285 - 255 - 200 - 2 x 1040 - - - 2080

305 305 - 275 - 220 - 2 x 1150 - - - 2300

325 325 - 295 - 240 - 2 x 1200 - - - 2400

345 345 - 315 - 260 - 2 x 1280 - - - 2560

365 365 - 335 - 280 - 2 x 1360 - - - 2720

385 385 - 355 - 300 - 2 x 1260 - - - 2520

VC V1E 205 ...

Lx2

*

*

Lx

X

V1E

V1E

-

205

CB ... M

Y=X=

Y=X=

VC

VC

125

J2 (mm)

max. 12

30 40

C (mm)

03 / 04 / 07 12

1)

2) 2)

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

2)

Nozzle size manifold can be used with

Length

code

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

Heater zones power (Watt)

requested pitch

dimensions

Nozzle series the manifold

will be combined with

1-port-I-manifold

1-port-I-manifold

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Plate bolts: M10 - 12.9 (2x per nozzle)

6 / 44

C P

T A

Page 8: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I2E 170

Lx

X X

170 170 - - - 40 - 2 x 560 - - - 1120

J2 (mm)

max. 12

30

C (mm)

03 / 04 / 07

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

I2E

I2E

-

170

CB ... M

Y=X=

Y=X=

VC

VC

45

3)

4)

1)

2) 2)

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Length

code

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2-port-I-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

3)

4)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the nozzles!

In case of lack of space use next larger manifold

type.

for X < 40 mm

for X 40 mm

Heater zones power (Watt)

2-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

7 / 44

C P

T A

Page 9: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I2E 210

Lx

X X

210 210 - - - 60 - 2 x 720 - - - 1440

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

-

210

CB ... M

Y=X=

Y=X=

VC

VC

65

I2E

I2E

1)

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

03 / 04 / 07 12

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

2-port-I-manifold

2-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

8 / 44

C P

T A

Page 10: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I2E 250 ...

Lx

Lx2

X X

250 250 - 270 - 80 - 2 x 880 - - - 1760

290 290 - 310 - 100 - 2 x 1040 - - - 2080

330 330 - 350 - 120 - 2 x 1200 - - - 2400

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

J2 (mm)

max. 12

30

34.5

40

40.537.5

C (mm)

Lb (mm)

03 / 04 / 07

ABK

12

ABL/ABTABM

-

250

CB ... M

Y=X=

Y=X=

VC

VC

85

I2E

I2E

1)

2) 2)

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

2-port-I-manifold

2-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

9 / 44

C P

T A

Page 11: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I2E 370 ...

Lx2

Lx

X X

I2E

I2E

-

370

CB ... M

Y=X=

Y=X=

VC

VC

145

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

*

*

1)

J2 (mm)

max. 12

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

370 370 - 390 - 140 - 2 x 640 2 x 640 - - 2560

410 410 - 430 - 160 - 2 x 720 2 x 720 - - 2880

450 450 - 470 - 180 - 2 x 560 2 x 560 - - 2240

490 490 - 510 - 200 - 2 x 880 2 x 880 - - 3520

530 530 - 550 - 220 - 2 x 672 2 x 672 - - 2688

570 570 - 590 - 240 - 2 x 1040 2 x 1040 - - 4160

610 610 - 630 - 260 - 2 x 1150 2 x 1150 - - 4600

650 650 - 670 - 280 - 2 x 1200 2 x 1200 - - 4800

690 690 - 710 - 300 - 2 x 1280 2 x 1280 - - 5120

2) 2)

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

2-port-I-manifold

2-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

10 / 44

C P

T A

Page 12: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I3E 170 ...

Lx2

Lx

170 170 - 190 - 40 - 2 x 600 - - - 1200

210 210 - 230 - 60 - 2 x 760 - - - 1520

250 250 - 270 - 80 - 2 x 644 - - - 1288

290 290 - 310 - 100 - 2 x 756 - - - 1512

330 330 - 350 - 120 - 2 x 1200 - - - 2400

-

170

CB ... M

Y=X=

Y=X=

VC

VC

45

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

*

*

I3E

I3E

1)

X X

2) 2)

J2 (mm)

max. 12

C (mm)

03 / 04 / 07 12

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

3-port-I-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

3-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

11 / 44

C P

T A

Page 13: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I3E 370 ...

Lx2

Lx

X X

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

*

*

-

370

CB ... M

Y=X=

Y=X=

VC

VC

145

I3E

I3E

1)

2) 2)

370 370 - 390 - 140 - 2 x 680 2 x 680 - - 2720

410 410 - 430 - 160 - 2 x 760 2 x 760 - - 3040

450 450 - 470 - 180 - 2 x 588 2 x 588 - - 2352

490 490 - 510 - 200 - 2 x 644 2 x 644 - - 2576

530 530 - 550 - 220 - 2 x 1000 2 x 1000 - - 4000

570 570 - 590 - 240 - 2 x 756 2 x 756 - - 3024

610 610 - 630 - 260 - 2 x 1000 2 x 1000 - - 4000

650 650 - 670 - 280 - 2 x 1200 2 x 1200 - - 4800

690 690 - 710 - 300 - 2 x 1000 2 x 1000 - - 4000

J2 (mm)

max. 12

C (mm)

03 / 04 / 07 12

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

3-port-I-manifold

3-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

12 / 44

C P

T A

Page 14: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC Y3E 085 ...

X

085 - 85 - 95 40 - 2 x 760 - - - 1520

105 - 105 - 115 60 - 2 x 1000 - - - 2000

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

*

*

-

085

CB ... M

Y=X=

Y=X=

VC

VC

45

Y3E

Y3E

J2 (mm)

max. 12

1)

C (mm)

03 / 04 / 07

30

3)

4)

2) 2)

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

3)

4)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the nozzles!

In case of lack of space use next larger manifold

type.

for X < 40 mm

for X 40 mm

Length

code

Heater zones power (Watt)

3-port-Y-manifold

3-port-Y-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

13 / 44

C P

T A

Page 15: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC Y3E 125 ...

125 - 125 - 135 80 - 2 x 1200 - - - 2400

145 - 145 - 155 100 - 2 x 1260 - - - 2520

165 - 165 - 175 120 - 2 x 1176 - - - 2352

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

-

125

CB ... M

Y=X=

Y=X=

VC

VC

85

Y3E

Y3E

J2 (mm)

max. 12

1)

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

2) 2)

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

3-port-Y-manifold

3-port-Y-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

14 / 44

C P

T A

Page 16: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

X

VC Y3E 180 ...

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

-

180

CB ... M

Y=X=

Y=X=

VC

VC

145

Y3E

Y3E

1)

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

180 - 180 - 190 140 - 2 x 560 2 x 560 2 x 560 - 3360

200 - 200 - 210 160 - 2 x 640 2 x 640 2 x 640 - 3840

220 - 220 - 230 180 - 2 x 720 2 x 720 2 x 720 - 4320

240 - 240 - 250 200 - 2 x 560 2 x 560 2 x 560 - 3360

260 - 260 - 270 220 - 2 x 880 2 x 880 2 x 880 - 5280

280 - 280 - 290 240 - 2 x 672 2 x 672 2 x 672 - 4032

300 - 300 - 310 260 - 2 x 1040 2 x 1040 2 x 1040 - 6240

320 - 320 - 330 280 - 2 x 1150 2 x 1150 2 x 1150 - 6900

340 - 340 - 350 300 - 2 x 1200 2 x 1200 2 x 1200 - 7200

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

3-port-Y-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

3-port-Y-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

15 / 44

C P

T A

Page 17: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC I4E 210 ...

210 210 - 230 - 40 - 2 x 760 - - - 1520

240 240 - 260 - 50 - 2 x 880 - - - 1760

270 270 - 290 - 60 - 2 x 1000 - - - 2000

300 300 - 320 - 70 - 2 x 1150 - - - 2300

1 2 3 4 1...4

Y

(mm)

X

(mm)

±5

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

Lx2

Lx

X X X

*

*

I4E

I4E

-

210

CB ... M

Y=X=

Y=X=

VC

VC

45

1)

2) 2)

J2 (mm)

max. 12

C (mm)

03 / 04 / 07

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-I-manifold

replaced by second dowel

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

16 / 44

C P

T A

Page 18: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

Lx2

Lx

X X X

VC I4E 330 ...

1 2 3 4 1...4

Y

(mm)

X

(mm)

±5

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

*

*

-

330

CB ... M

Y=X=

Y=X=

VC

VC

85

I4E

I4E

1)

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

03 / 04 / 07 12

1203 04 07

330 330 - 350 - 80 - 2 x 600 2 x 600 - - 2400

360 360 - 380 - 90 - 2 x 640 2 x 640 - - 2560

390 390 - 410 - 100 - 2 x 720 2 x 720 - - 2880

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-I-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-I-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

17 / 44

C P

T A

Page 19: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H4E 160 146 ...

160 146 160 146 180 166 40 40 2 x 1200 - - - 2400

160 166 160 166 180 186 40 50 2 x 1000 - - - 2000

Lx2

Lx

X X

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

*

*

H4E

H4E

45

160 146

CB ... M

Y=X=

Y=X=

VC

VC

45

1)

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

03 / 04 / 07 12

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-H-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

18 / 44

C P

T A

Page 20: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H4E 160 186 ...

Lx2

Lx

X X

*

*

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

65

160 186

CB ... M

Y=X=

Y=X=

VC

VC

45

H4E

H4E

1)

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

160 186 160 186 180 206 40 60 2 x 1150 - - - 2300

200 186 200 186 220 206 60 60 2 x 1204 - - - 2408

160 206 160 206 180 226 40 70 2 x 1036 - - - 2072

200 206 200 206 220 226 60 70 2 x 1260 - - - 2520

160 226 160 226 180 246 40 80 2 x 1240 - - - 2480

200 226 200 226 226 246 60 80 2 x 1310 - - - 2620

240 226 240 226 260 246 80 80 2 x 1400 - - - 2800

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-H-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

19 / 44

C P

T A

Page 21: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H4E 160 246 ...

Lx2

Lx

X X

*

*

95

160 246

CB ... M

Y=X=

Y=X=

VC

VC

45

H4E

H4E

1)

J2 (mm)

max. 12

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

4-port-H-manifold

Plate bolts:

M10 - 12.9 (2x per nozzle)

20 / 44

C P

T A

Page 22: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

1 2 3 4 1...4

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

VC H4E 160 246 ...

160 246 160 246 180 266 40 90 2 x 720 2 x 720 - - 2880

200 246 200 246 220 266 60 90 2 x 880 2 x 880 - - 3520

240 246 240 246 260 266 80 90 2 x 1040 2 x 1040 - - 4160

160 266 160 266 180 286 40 100 2 x 760 2 x 760 - - 3040

200 266 200 266 220 286 60 100 2 x 644 2 x 644 - - 2576

240 266 240 266 260 286 80 100 2 x 756 2 x 756 - - 3024

280 266 280 266 300 286 100 100 2 x 1200 2 x 1200 - - 4800

160 286 160 286 180 306 40 110 2 x 560 2 x 560 - - 2240

200 286 200 286 220 306 60 110 2 x 672 2 x 672 - - 2688

240 286 240 286 260 306 80 110 2 x 1150 2 x 1150 - - 4600

280 286 280 286 300 306 100 110 2 x 1280 2 x 1280 - - 5120

160 306 160 306 180 326 40 120 2 x 588 2 x 588 - - 2352

200 306 200 306 220 326 60 120 2 x 1000 2 x 1000 - - 4000

240 306 240 306 260 326 80 120 2 x 1000 2 x 1000 - - 4000

280 306 280 306 300 326 100 120 2 x 1000 2 x 1000 - - 4000

320 306 320 306 340 326 120 120 2 x 1036 2 x 1036 - - 4144

160 326 160 326 180 346 40 130 2 x 880 2 x 880 - - 3520

200 326 200 326 220 346 60 130 2 x 1040 2 x 1040 - - 4160

240 326 240 326 260 346 80 130 2 x 1200 2 x 1200 - - 4800

280 326 280 326 300 346 100 130 2 x 1360 2 x 1360 - - 5440

320 326 320 326 340 346 120 130 2 x 1064 2 x 1064 - - 4256

160 346 160 346 180 366 40 140 2 x 644 2 x 644 - - 2576

200 346 200 346 220 366 60 140 2 x 756 2 x 756 - - 3024

240 346 240 346 260 366 80 140 2 x 1200 2 x 1200 - - 4800

280 346 280 346 300 366 100 140 2 x 1150 2 x 1150 - - 4600

320 346 320 346 340 366 120 140 2 x 1240 2 x 1240 - - 4960

360 346 360 346 380 366 140 140 2 x 1204 2 x 1204 - - 4816

160 366 160 366 180 386 40 150 2 x 672 2 x 672 - - 2688

200 366 200 366 220 386 60 150 2 x 1150 2 x 1150 - - 4600

240 366 240 366 260 386 80 150 2 x 1280 2 x 1280 - - 5120

280 366 280 366 300 386 100 150 2 x 1260 2 x 1260 - - 5040

320 366 320 366 340 386 120 150 2 x 1120 2 x 1120 - - 4480

360 366 360 366 380 386 140 150 2 x 1232 2 x 1232 - - 4928

160 386 160 386 180 406 40 160 2 x 1000 2 x 1000 - - 4000

200 386 200 386 220 406 60 160 2 x 1000 2 x 1000 - - 4000

240 386 240 386 260 406 80 160 2 x 1000 2 x 1000 - - 4000

280 386 280 386 300 406 100 160 2 x 1036 2 x 1036 - - 4144

320 386 320 386 340 406 120 160 2 x 1148 2 x 1148 - - 4592

360 386 360 386 380 406 140 160 2 x 1260 2 x 1260 - - 5040

400 386 400 386 420 406 160 160 2 x 1372 2 x 1372 - - 5488

Y

(mm)

±5

X

(mm)

±10

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Length

code

Heater zones power (Watt)

4-port-H-manifold

21 / 44

C P

T A

Page 23: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H4E 160 406 ...

Lx

X

J1

Lx2

Lx

X X

*

*

175

160 406

CB ... M

Y=X=

Y=X=

VC

VC

45

H4E

H4E

1)

J2 (mm)

max. 12

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

4-port-H-manifold

Plate bolts:

M10 - 12.9 (2x per nozzle)

22 / 44

C P

T A

Page 24: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H4E 160 406 ...

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

160 406 160 406 180 426 40 170 2 x 720 2 x 720 2 x 560 - 2880

200 406 200 406 220 426 60 170 2 x 880 2 x 880 2 x 560 - 3520

240 406 240 406 260 426 80 170 2 x 1040 2 x 1040 2 x 560 - 4160

280 406 280 406 300 426 100 170 2 x 1200 2 x 1200 2 x 560 - 4800

160 426 160 426 180 446 40 180 2 x 760 2 x 760 2 x 560 - 3040

200 426 200 426 220 446 60 180 2 x 644 2 x 644 2 x 560 - 2576

240 426 240 426 260 446 80 180 2 x 756 2 x 756 2 x 560 - 3024

280 426 280 426 300 446 100 180 2 x 1200 2 x 1200 2 x 560 - 4800

160 446 160 446 180 466 40 190 2 x 560 2 x 560 2 x 560 - 2240

200 446 200 446 220 466 60 190 2 x 672 2 x 672 2 x 560 - 2688

240 446 240 446 260 466 80 190 2 x 1150 2 x 1150 2 x 560 - 4600

280 446 280 446 300 466 100 190 2 x 1280 2 x 1280 2 x 560 - 5120

160 466 160 466 180 486 40 200 2 x 588 2 x 588 2 x 560 - 2352

200 466 200 466 220 486 60 200 2 x 1000 2 x 1000 2 x 560 - 4000

240 466 240 466 260 486 80 200 2 x 1000 2 x 1000 2 x 560 - 4000

280 466 280 466 300 486 100 200 2 x 1000 2 x 1000 2 x 560 - 4000

160 486 160 486 180 506 40 210 2 x 880 2 x 880 2 x 560 - 3520

200 486 200 486 220 506 60 210 2 x 1040 2 x 1040 2 x 560 - 4160

240 486 240 486 260 506 80 210 2 x 1200 2 x 1200 2 x 560 - 4800

280 486 280 486 300 506 100 210 2 x 1360 2 x 1360 2 x 560 - 5440

160 506 160 506 180 526 40 220 2 x 644 2 x 644 2 x 560 - 2576

200 506 200 506 220 526 60 220 2 x 756 2 x 756 2 x 560 - 3024

240 506 240 506 260 526 80 220 2 x 1200 2 x 1200 2 x 560 - 4800

280 506 280 506 300 526 100 220 2 x 1150 2 x 1150 2 x 560 - 4600

160 526 160 526 180 546 40 230 2 x 672 2 x 672 2 x 560 - 2688

200 526 200 526 220 546 60 230 2 x 1150 2 x 1150 2 x 560 - 4600

240 526 240 526 260 546 80 230 2 x 1280 2 x 1280 2 x 560 - 5120

280 526 280 526 300 546 100 230 2 x 1260 2 x 1260 2 x 560 - 5040

160 546 160 546 180 566 40 240 2 x 1000 2 x 1000 2 x 560 - 4000

200 546 200 546 220 566 60 240 2 x 1000 2 x 1000 2 x 560 - 4000

240 546 240 546 260 566 80 240 2 x 1000 2 x 1000 2 x 560 - 4000

280 546 280 546 300 566 100 240 2 x 1036 2 x 1036 2 x 560 - 4144

160 566 160 566 180 586 40 250 2 x 1040 2 x 1040 2 x 560 - 4160

200 566 200 566 220 586 60 250 2 x 1200 2 x 1200 2 x 560 - 4800

240 566 240 566 260 586 80 250 2 x 1360 2 x 1360 2 x 560 - 5440

280 566 280 566 300 586 100 250 2 x 1064 2 x 1064 2 x 560 - 4256

160 586 160 586 180 606 40 260 2 x 756 2 x 756 2 x 560 - 3024

200 586 200 586 220 606 60 260 2 x 1200 2 x 1200 2 x 560 - 4800

240 586 240 586 260 606 80 260 2 x 1150 2 x 1150 2 x 560 - 4600

280 586 280 586 300 606 100 260 2 x 1240 2 x 1240 2 x 560 - 4960

160 606 160 606 180 626 40 270 2 x 1150 2 x 1150 2 x 560 - 4600

200 606 200 606 220 626 60 270 2 x 1280 2 x 1280 2 x 560 - 5120

240 606 240 606 260 626 80 270 2 x 1260 2 x 1260 2 x 560 - 5040

280 606 280 606 300 626 100 270 2 x 1120 2 x 1120 2 x 560 - 4480

160 626 160 626 180 646 40 280 2 x 1000 2 x 1000 2 x 560 - 4000

200 626 200 626 220 646 60 280 2 x 1000 2 x 1000 2 x 560 - 4000

240 626 240 626 260 646 80 280 2 x 1036 2 x 1036 2 x 560 - 4144

280 626 280 626 300 646 100 280 2 x 1148 2 x 1148 2 x 560 - 4592

160 646 160 646 180 666 40 290 2 x 1200 2 x 1200 2 x 560 - 4800

200 646 200 646 220 666 60 290 2 x 1360 2 x 1360 2 x 560 - 5440

240 646 240 646 260 666 80 290 2 x 1064 2 x 1064 2 x 560 - 4256

280 646 280 646 300 666 100 290 2 x 1176 2 x 1176 2 x 560 - 4704

160 666 160 666 180 686 40 300 2 x 1200 2 x 1200 2 x 560 - 4800

200 666 200 666 220 686 60 300 2 x 1150 2 x 1150 2 x 560 - 4600

240 666 240 666 260 686 80 300 2 x 1240 2 x 1240 2 x 560 - 4960

280 666 280 666 300 686 100 300 2 x 1204 2 x 1204 2 x 560 - 4816

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Length

code

Heater zones power (Watt)

4-port-H-manifold

23 / 44

C P

T A

Page 25: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC X4E 202 ...

Lx

X X

Lx2

Xp

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

202 202 - 222 - 60 - 2 x 1240 - - - 2480

242 242 - 262 - 80 - 2 x 1400 - - - 2800

X4E

X4E

-

202

CB ... M

Y=X=

Y=X=

VC

VC

65

1)

2) 2)

J2 (mm)

max. 12

30

128

69

40

157

83

C (mm)

Xp (mm)

Xw (mm)

Lb (mm)

03 / 04 / 07

202

202

12

242

242

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

for Lx =

for Lx =

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

24 / 44

C P

T A

Page 26: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC X4E 282 ...

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

Lx

X X

Lx2

Xp

*

*

-

282

CB ... M

Y=X=

Y=X=

VC

VC

105

X4E

X4E

1)

282 282 - 302 - 100 - 2 x 1000 2 x 1000 - - 4000

322 322 - 342 - 120 - 2 x 1150 2 x 1150 - - 4600

2) 2)

J2 (mm)

max. 12

30

185

97

40

213

111

C (mm)

Xp (mm)

Xw (mm)

Lb (mm)

03 / 04 / 07

282

282

12

322

322

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

for Lx =

for Lx =

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

25 / 44

C P

T A

Page 27: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC X4E 362 ...

Lx

X X

Lx2

Xp

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

-

362

CB ... M

Y=X=

Y=X=

VC

VC

145

X4E

X4E

1)

362 362 - 382 - 140 - 2 x 760 2 x 760 2 x 760 2 x 760 6080

402 402 - 422 - 160 - 2 x 880 2 x 880 2 x 880 2 x 880 7040

442 442 - 462 - 180 - 2 x 1000 2 x 1000 2 x 1000 2 x 1000 8000

482 482 - 502 - 200 - 2 x 756 2 x 756 2 x 756 2 x 756 6048

522 522 - 542 - 220 - 2 x 1200 2 x 1200 2 x 1200 2 x 1200 9600

562 562 - 582 - 240 - 2 x 1000 2 x 1000 2 x 1000 2 x 1000 8000

602 602 - 622 - 260 - 2 x 1260 2 x 1260 2 x 1260 2 x 1260 10080

642 642 - 662 - 280 - 2 x 1240 2 x 1240 2 x 1240 2 x 1240 9920

682 682 - 702 - 300 - 2 x 1148 2 x 1148 2 x 1148 2 x 1148 9184

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

Xp (mm)

Xw (mm)

Lb (mm)

03 / 04 / 07 12

362

362

402

402

442

442

482

482

522

522

562

562

602

602

642

642

682

682

242

152

270

176

298

190

326

204

355

218

383

232

411

246

439

260

468

275

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

for Lx =

for Lx =

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

4-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

26 / 44

C P

T A

Page 28: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC XSE

X X

*

*

120 CB ... M

Y=X=

Y=X=

VC

VC

170

XSE

XSE

1)

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

170..

..300

120..

..300

2) 2)

J2 (mm)

max. 12

30 40

C (mm)

Lb (mm)

03 / 04 / 07 12

ABK ABL/ABTABM

34.5 40.537.5

2 x

max.

1400 2 x

max.

1400 2 x

max.

1400 2 x

max.

1400

max.

11200

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

4-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

Dimensions on request

4-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

27 / 44

C P

T A

Page 29: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC Y6E 232 ...

Lx2

Xp

Lx

X X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

232 232 152 252 172 80 - 2 x 1036 - - - 2072

272 272 172 292 192 100 - 2 x 1400 - - - 2800

312 312 192 332 212 120 - 2 x 1400 - - - 2800

Y6E

Y6E

-

232

CB ... M

Y=X=

Y=X=

VC

VC

80

1)

2) 2)

J2 (mm)

max. 12

30

91.5 101.5

40

111.5

C (mm)

Xp (mm)

Lb (mm)

03 / 04 / 07

232 272

12

312

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

6-port-Y-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

for Lx =

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

6-port-Y-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

28 / 44

C P

T A

Page 30: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC Y6E 352 ...

Lx2

Xp

Lx

X X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

352 352 212 372 232 140 - 2 x 1150 - - - 2300

392 392 232 412 252 160 - 2 x 1120 - - - 2240

432 432 252 452 272 180 - 2 x 1260 - - - 2520

472 472 272 492 292 200 - 2 x 1400 - - - 2800

-

352

CB ... M

Y=X=

Y=X=

VC

VC

140

Y6E

Y6E

1)

2) 2)

J2 (mm)

max. 12

30

138.5 148.5

40

158.5 168.5

C (mm)

Xp (mm)

Lb (mm)

03 / 04 / 07

352 392

12

432 472

ABK ABL/ABTABM

34.5 40.537.5

1203 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

6-port-Y-manifold

2)

Nozzle size manifold can be used with

for nozzle size for nozzle size

for Lx =

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

6-port-Y-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

29 / 44

C P

T A

Page 31: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H6E 160 146 ...

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

Lx

X X

Lx2

*

*

160 146 160 146 180 166 40 40 2 x 1200 - - - 2400

160 166 160 166 180 186 40 50 2 x 1000 - - - 2000

H6E

H6E

45

160 146

CB ... M

Y=X=

Y=X=

VC

VC

45

1)

2) 2)

J2 (mm)

max. 12

30

C (mm)

03 / 04 / 07

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

6-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

6-port-H-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

30 / 44

C P

T A

Page 32: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H6E 160 186 ...

Lx2

Lx

X X

*

*

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

160 186 160 186 180 206 40 60 2 x 1150 - - - 2300

200 186 200 186 220 206 60 60 2 x 1204 - - - 2408

160 206 160 206 180 226 40 70 2 x 1036 - - - 2072

200 206 200 206 220 226 60 70 2 x 1260 - - - 2520

160 226 160 226 180 246 40 80 2 x 1240 - - - 2480

200 226 200 226 220 246 60 80 2 x 1310 - - - 2620

240 226 240 226 260 246 80 80 2 x 1400 - - - 2800

65

160 186

CB ... M

Y=X=

Y=X=

VC

VC

45

H6E

H6E

1)

2) 2)

J2 (mm)

max. 12

30

C (mm)

Lb (mm)

03 / 04 / 07

ABK ABL/ABTABM

34.5 40.537.5

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

6-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

6-port-H-manifold

Plate bolts:

M10 - 12.9 (2x per nozzle)

31 / 44

C P

T A

Page 33: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H6E 160 246 ...

Lx2

Lx

X X

*

*

95

160 246

CB ... M

Y=X=

Y=X=

VC

VC

45

H6E

H6E

1)

J2 (mm)

max. 12

30

C (mm)

Lb (mm)

03 / 04 / 07

ABK ABL/ABTABM

34.5 40.537.5

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

6-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

6-port-H-manifold

Plate bolts:

M10 - 12.9 (2x per nozzle)

32 / 44

C P

T A

Page 34: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H6E 160 246 ...

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

160 246 160 246 180 266 40 90 2 x 720 2 x 720 - - 2880

200 246 200 246 220 266 60 90 2 x 880 2 x 880 - - 3520

240 246 240 246 260 266 80 90 2 x 1040 2 x 1040 - - 4160

160 266 160 266 180 286 40 100 2 x 760 2 x 760 - - 3040

200 266 200 266 220 286 60 100 2 x 644 2 x 644 - - 2576

240 266 240 266 260 286 80 100 2 x 756 2 x 756 - - 3024

280 266 280 266 300 286 100 100 2 x 1200 2 x 1200 - - 4800

160 286 160 286 180 306 40 110 2 x 560 2 x 560 - - 2240

200 286 200 286 220 306 60 110 2 x 672 2 x 672 - - 2688

240 286 240 286 260 306 80 110 2 x 1150 2 x 1150 - - 4600

280 286 280 286 300 306 100 110 2 x 1280 2 x 1280 - - 5120

160 306 160 306 180 326 40 120 2 x 588 2 x 588 - - 2352

200 306 200 306 220 326 60 120 2 x 1000 2 x 1000 - - 4000

240 306 240 306 260 326 80 120 2 x 1000 2 x 1000 - - 4000

280 306 280 306 300 326 100 120 2 x 1000 2 x 1000 - - 4000

320 306 320 306 340 326 120 120 2 x 1036 2 x 1036 - - 4144

160 326 160 326 180 346 40 130 2 x 880 2 x 880 - - 3520

200 326 200 326 220 346 60 130 2 x 1040 2 x 1040 - - 4160

240 326 240 326 260 346 80 130 2 x 1200 2 x 1200 - - 4800

280 326 280 326 300 346 100 130 2 x 1360 2 x 1360 - - 5440

320 326 320 326 340 346 120 130 2 x 1064 2 x 1064 - - 4256

160 346 160 346 180 366 40 140 2 x 644 2 x 644 - - 2576

200 346 200 346 220 366 60 140 2 x 756 2 x 756 - - 3024

240 346 240 346 260 366 80 140 2 x 1200 2 x 1200 - - 4800

280 346 280 346 300 366 100 140 2 x 1150 2 x 1150 - - 4600

320 346 320 346 340 366 120 140 2 x 1240 2 x 1240 - - 4960

360 346 360 346 380 366 140 140 2 x 1204 2 x 1204 - - 4816

160 366 160 366 180 386 40 150 2 x 672 2 x 672 - - 2688

200 366 200 366 220 386 60 150 2 x 1150 2 x 1150 - - 4600

240 366 240 366 260 386 80 150 2 x 1280 2 x 1280 - - 5120

280 366 280 366 300 386 100 150 2 x 1260 2 x 1260 - - 5040

320 366 320 366 340 386 120 150 2 x 1120 2 x 1120 - - 4480

360 366 360 366 380 386 140 150 2 x 1232 2 x 1232 - - 4928

160 386 160 386 180 406 40 160 2 x 1000 2 x 1000 - - 4000

200 386 200 386 220 406 60 160 2 x 1000 2 x 1000 - - 4000

240 386 240 386 260 406 80 160 2 x 1000 2 x 1000 - - 4000

280 386 280 386 300 406 100 160 2 x 1036 2 x 1036 - - 4144

320 386 320 386 340 406 120 160 2 x 1148 2 x 1148 - - 4592

360 386 360 386 380 406 140 160 2 x 1260 2 x 1260 - - 5040

400 386 400 386 420 406 160 160 2 x 1372 2 x 1372 - - 5488

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Length

code

Heater zones power (Watt)

6-port-H-manifold

33 / 44

C P

T A

Page 35: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H6E 160 406 ...

Lx2

Lx

X X

*

*

175

160 406

CB ... M

Y=X=

Y=X=

VC

VC

45

H6E

H6E

1)

J2 (mm)

max. 12

30

C (mm)

Lb (mm)

03 / 04 / 07

ABK ABL/ABTABM

34.5 40.537.5

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

6-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

6-port-H-manifold

Plate bolts:

M10 - 12.9 (2x per nozzle)

34 / 44

C P

T A

Page 36: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H6E 160 406 ...

1 2 3 4 1...4

Y

(mm)

±5

X

(mm)

±10

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

160 406 160 406 180 426 40 170 2 x 720 2 x 720 2 x 560 - 2880

200 406 200 406 220 426 60 170 2 x 880 2 x 880 2 x 560 - 3520

240 406 240 406 260 426 80 170 2 x 1040 2 x 1040 2 x 560 - 4160

280 406 280 406 300 426 100 170 2 x 1200 2 x 1200 2 x 560 - 4800

160 426 160 426 180 446 40 180 2 x 760 2 x 760 2 x 560 - 3040

200 426 200 426 220 446 60 180 2 x 644 2 x 644 2 x 560 - 2576

240 426 240 426 260 446 80 180 2 x 756 2 x 756 2 x 560 - 3024

280 426 280 426 300 446 100 180 2 x 1200 2 x 1200 2 x 560 - 4800

160 446 160 446 180 466 40 190 2 x 560 2 x 560 2 x 560 - 2240

200 446 200 446 220 466 60 190 2 x 672 2 x 672 2 x 560 - 2688

240 446 240 446 260 466 80 190 2 x 1150 2 x 1150 2 x 560 - 4600

280 446 280 446 300 466 100 190 2 x 1280 2 x 1280 2 x 560 - 5120

160 466 160 466 180 486 40 200 2 x 588 2 x 588 2 x 560 - 2352

200 466 200 466 220 486 60 200 2 x 1000 2 x 1000 2 x 560 - 4000

240 466 240 466 260 486 80 200 2 x 1000 2 x 1000 2 x 560 - 4000

280 466 280 466 300 486 100 200 2 x 1000 2 x 1000 2 x 560 - 4000

160 486 160 486 180 506 40 210 2 x 880 2 x 880 2 x 560 - 3520

200 486 200 486 220 506 60 210 2 x 1040 2 x 1040 2 x 560 - 4160

240 486 240 486 260 506 80 210 2 x 1200 2 x 1200 2 x 560 - 4800

280 486 280 486 300 506 100 210 2 x 1360 2 x 1360 2 x 560 - 5440

160 506 160 506 180 526 40 220 2 x 644 2 x 644 2 x 560 - 2576

200 506 200 506 220 526 60 220 2 x 756 2 x 756 2 x 560 - 3024

240 506 240 506 260 526 80 220 2 x 1200 2 x 1200 2 x 560 - 4800

280 506 280 506 300 526 100 220 2 x 1150 2 x 1150 2 x 560 - 4600

160 526 160 526 180 546 40 230 2 x 672 2 x 672 2 x 560 - 2688

200 526 200 526 220 546 60 230 2 x 1150 2 x 1150 2 x 560 - 4600

240 526 240 526 260 546 80 230 2 x 1280 2 x 1280 2 x 560 - 5120

280 526 280 526 300 546 100 230 2 x 1260 2 x 1260 2 x 560 - 5040

160 546 160 546 180 566 40 240 2 x 1000 2 x 1000 2 x 560 - 4000

200 546 200 546 220 566 60 240 2 x 1000 2 x 1000 2 x 560 - 4000

240 546 240 546 260 566 80 240 2 x 1000 2 x 1000 2 x 560 - 4000

280 546 280 546 300 566 100 240 2 x 1036 2 x 1036 2 x 560 - 4144

160 566 160 566 180 586 40 250 2 x 1040 2 x 1040 2 x 560 - 4160

200 566 200 566 220 586 60 250 2 x 1200 2 x 1200 2 x 560 - 4800

240 566 240 566 260 586 80 250 2 x 1360 2 x 1360 2 x 560 - 5440

280 566 280 566 300 586 100 250 2 x 1064 2 x 1064 2 x 560 - 4256

160 586 160 586 180 606 40 260 2 x 756 2 x 756 2 x 560 - 3024

200 586 200 586 220 606 60 260 2 x 1200 2 x 1200 2 x 560 - 4800

240 586 240 586 260 606 80 260 2 x 1150 2 x 1150 2 x 560 - 4600

280 586 280 586 300 606 100 260 2 x 1240 2 x 1240 2 x 560 - 4960

160 606 160 606 180 626 40 270 2 x 1150 2 x 1150 2 x 560 - 4600

200 606 200 606 220 626 60 270 2 x 1280 2 x 1280 2 x 560 - 5120

240 606 240 606 260 626 80 270 2 x 1260 2 x 1260 2 x 560 - 5040

280 606 280 606 300 626 100 270 2 x 1120 2 x 1120 2 x 560 - 4480

160 626 160 626 180 646 40 280 2 x 1000 2 x 1000 2 x 560 - 4000

200 626 200 626 220 646 60 280 2 x 1000 2 x 1000 2 x 560 - 4000

240 626 240 626 260 646 80 280 2 x 1036 2 x 1036 2 x 560 - 4144

280 626 280 626 300 646 100 280 2 x 1148 2 x 1148 2 x 560 - 4592

160 646 160 646 180 666 40 290 2 x 1200 2 x 1200 2 x 560 - 4800

200 646 200 646 220 666 60 290 2 x 1360 2 x 1360 2 x 560 - 5440

240 646 240 646 260 666 80 290 2 x 1064 2 x 1064 2 x 560 - 4256

280 646 280 646 300 666 100 290 2 x 1176 2 x 1176 2 x 560 - 4704

160 666 160 666 180 686 40 300 2 x 1200 2 x 1200 2 x 560 - 4800

200 666 200 666 220 686 60 300 2 x 1150 2 x 1150 2 x 560 - 4600

240 666 240 666 260 686 80 300 2 x 1240 2 x 1240 2 x 560 - 4960

280 666 280 666 300 686 100 300 2 x 1204 2 x 1204 2 x 560 - 4816

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Length

code

Heater zones power (Watt)

6-port-H-manifold

35 / 44

C P

T A

Page 37: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H8E 168

Lx

X X X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±2.5

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

168 168 90 - - 30.5 - 2 x 720 - - - 1440

H8E

H8E

-

168

04 C01

Y=X=

Y=X=

VC

VC

33

1)

2) 2)

J2 (mm)

max. 12

C (mm)

03 / 04

03 04

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

8-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

replaced by second dowel

Length

code

Heater zones power (Watt)

8-port-H-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

36 / 44

C P

T A

Page 38: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H8E 188 ...

Lx

Lx2

X X X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

-

188

CB ... M

Y=X=

Y=X=

VC

VC

40

H8E

H8E

188 188 98 208 118

36.5

±3.5

- 2 x 588 - - - 1176

218 218 100 238 128

45

±5

- 2 x 756 - - - 1512

1)

2) 2)

J2 (mm)

max. 12

C (mm)

03 / 04 / 07

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

8-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

replaced by second dowel

Length

code

Heater zones power (Watt)

8-port-H-manifold

Plate bolts:

M10 - 12.9

(2x per nozzle)

37 / 44

C P

T A

Page 39: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC H8E 248 ...

Lx

Lx2

X X X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

±5

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

248 248 118 268 138 55 - 2 x 1280 - - - 2560

278 278 128 298 148 65 - 2 x 1260 - - - 2520

-

248

CB ... M

Y=X=

Y=X=

VC

VC

60

H8E

H8E

1)

2) 2)

J2 (mm)

max. 12

C (mm)

03 / 04 / 07

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

8-port-H-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

replaced by second dowel

Length

code

Heater zones power (Watt)

8-port-H-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

38 / 44

C P

T A

Page 40: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC Y12E 240 ...

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

Y12E

Y12E

-

240

CB ... M

Y=X=

Y=X=

VC

VC

60

2) 2)

240 240 180 260 200 60 - 2 x 1040 2 x 1040 - - 4160

270 270 200 290 220 70 - 2 x 1000 2 x 1000 - - 4000

J2 (mm)

max. 12

30

C (mm)

03 / 04 / 07

03 04 07

Lx

Lx2

X X X

*

*

1)

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

12-port-Y-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

12-port-Y-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

39 / 44

C P

T A

Page 41: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC X16E 236 ...

Lx

Lx2

X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

X16E

X16E

-

236

CB ... M

Y=X=

Y=X=

VC

VC

60

1)

2) 2)

J2 (mm)

max. 12

30

C (mm)

03 / 04 / 07

236 236 - 256 - 60 - 2 x 1000 2 x 1000 - - 4000

266 266 - 286 - 70 - 2 x 1036 2 x 1036 - - 4144

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

16-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

16-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

40 / 44

C P

T A

Page 42: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC X24E 356 ...

Lx2

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

X24E

X24E

-

356

CB ... M

Y=X=

Y=X=

VC

VC

60

1)

2) 2)

J2 (mm)

max. 12

30

C (mm)

03 / 04 / 07

356 356 236 386 266 60 - 2 x 1000 2 x 1000 2 x 1000 - 6000

406 406 266 436 296 70 - 2 x 1036 2 x 1036 2 x 1036 - 6216

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

24-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

24-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

41 / 44

C P

T A

Page 43: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC X32E 476 ...

Lx

Lx2

X

*

*

1 2 3 4 1...4

Y

(mm)

X

(mm)

Ly2

(mm)

Lx2

(mm)

Ly

(mm)

Lx

(mm)

X32E

X32E

-

476

CB ... M

Y=X=

Y=X=

VC

VC

60

1)

2) 2)

J2 (mm)

max. 12

30

C (mm)

03 / 04 / 07

476 476 236 506 266 60 - 2 x 1000 2 x 1000 2 x 1000 2 x 1000 8000

546 546 266 576 296 70 - 2 x 1036 2 x 1036 2 x 1036 2 x 1036 8288

03 04 07

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

You can configure your manifold here

1. Complete the manifold description

2. Selection of variables

Series & Type

Nozzle series

Length code

Example and explanations

Series Position in manifold

length chart

Series & Type Length code

Type

requested pitch

dimensions

Nozzle series the manifold

will be combined with

32-port-X-manifold

2)

Nozzle size manifold can be used with

for nozzle size

*The values of these dimensions depend on the

selected nozzle series. They can be found in the

Synventive Hot Runner Guide.

1)

2)

Hardened insert recommended; is not supplied

with the hot runner system.

Provide enough installation space for the

nozzles! In case of lack of space use next larger

manifold type.

Length

code

Heater zones power (Watt)

32-port-X-manifold

Plate bolts: M10 - 12.9 (2x per nozzle)

42 / 44

C P

T A

Page 44: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Manifolds in customised shape

Manifolds in customised shape are designed

and made according to the customer’s

specification by using components of the

selected manifold series.

Shown on the right there is a manifold in

customised shape which has been designed

by using components of series .VC

Series

43 / 44

C P

T A

Page 45: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

VC

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

Series

Bridge manifolds

Bridge manifolds make it possible to combine

several manifolds to one feed system. They

are are designed and made according to the

customer’s specification by using components

of the selected manifold series.

Shown on the right there is a bridge manifold

which has been designed by using

components of series .VC

44 / 44

C P

T A

Page 46: C P Hot Runner Manifolds T A - Niulira · Illustrations simplified,schematicallydrawn and not to scale. Inlet bushings Series 2. Selection of variables Exampleand explanations Type

For design and application information,

see the Synventive Hot Runner Guide.

2006-08-01 - All rights reserved. Errors and omissions excepted.

For a specific application, please consult Synventive.

Illustrations simplified, schematically drawn and not to scale.

C P

T A

AU - Australia +61 3 9886 3475 [email protected]

BR - Brasil - Brazil +55 (0)11 6191 3433 [email protected]

CA - Canada +1 514-421-8963

+1 604-943-7702

[email protected]

[email protected]

CN - People's Republic of China +86 512 62838870

+86 755 82315175

[email protected]

CZ - Czech Rebpublic +420 326 992 038 [email protected]

DE - Germany +49 (0) 6251 9332-0 [email protected]

DK - Denmark +45 33931629 [email protected]

ES - Spain +34 93 565 15 00 [email protected]

FI - Finland +358(0)207 519 600 [email protected]

FR - France +33 (0) 474991600 [email protected]

GB - Great Britain +44 (0) 1527577417 [email protected]

IL - Israel +972-3-7325446 [email protected]

IN - India +91 80 2558 0024 [email protected]

IT - Italy +39 0266505373 [email protected]

JP - Japan + 81 45 472 1239 [email protected]

NL - The Netherlands +31 (0) 786738282 [email protected]

PL - Poland +48 (0) 52 323 12 00 [email protected]

PT - Portugal +351 244829790 [email protected]

SG - Singapore +65 65368093 [email protected]

SK - Slovak Republic +421 (0)2 63 82 92 48 [email protected]

US - United States of America +1 800.367.5662

+1 248.457.0761

[email protected]