Building & Fire - Kelair Pumps Australia · BUILDING & FIRE DIVISION Kelair’s Building & Fire...

4
BUILDING & FIRE DIVISION Kelair’s Building & Fire Division was established in 1994. It is one of the most technically-competent suppliers to the construction and plumbing industries. The Division’s aim is to support customers from project conception via consultants, through the construction defects’ liability period and beyond, providing on-going routine maintenance performed by our own skilled service technicians. Customers receive peace of mind, as Kelair provides fully-compliant units, CAD drawings and technical specifications. Kelair’s extensive range of packaged automatic pressure systems are designed for ease of installation with all necessary components pre-assembled on a common baseplate ready for simple suction and discharge plumbing connection and single point electrical connection. Applications Hot and cold water booster systems Hot and cold water pressure systems Submersible pressure systems General water transfer Rainwater re-use Irrigation Range Fixed or variable speed Single and multiple units Single or multistage pumps Horizontal or vertical pumps Fully-manifold systems Alternative manifold materials: PE/Poly/Stainless Steel/Copper PACKAGED PRESSURE SYSTEMS & BOOSTERS DIESEL & ELECTRIC HYDRANT BOOSTER PUMPS Kelair offers fully-compliant AS2941, fully-packaged hydrant booster pumps com- plete will fully-valved suction and discharge manifolds and by-pass line. Packaged systems provide simple installation. All units are factory tested prior to delivery and are supported by Kelair’s field service technicians. Pressure -sustaining relief valves NFPA 20 & FM-approved versions also available Annubar test lines Automatic and manual jacking pumps On-site commissioning On-site flow tests FIRE SPRINKLER PUMPSETS A complete range of fire sprinkler pumpsets for applications such as high-rise buildings, low-rise buildings, hospitals, mine sites, industrial factories and pro- cessing plants. Units can be supplied to comply with the following standards: AS2941/AS2118 NFPA20 and FM approved versions also available ESFR and High-hazard systems Fully-valved suction and discharge manifolds Annubar test lines Pressure sustaining / relief valves Annubar jacking pumps On-site commissioning Building & Fire ‘When Pump Knowledge Matters’ Call 1300 789 466

Transcript of Building & Fire - Kelair Pumps Australia · BUILDING & FIRE DIVISION Kelair’s Building & Fire...

BUILDING & FIRE DIVISION

Kelair’s Building & Fire Division was established in 1994. It is one of the most

technically-competent suppliers to the construction and plumbing industries.

The Division’s aim is to support customers from project conception via consultants,

through the construction defects’ liability period and beyond, providing on-going routine

maintenance performed by our own skilled service technicians.

Customers receive peace of mind, as Kelair provides fully-compliant units, CAD drawings

and technical specifications.

Kelair’s extensive range of packaged automatic pressure systems are designed

for ease of installation with all necessary components pre-assembled on a common

baseplate ready for simple suction and discharge plumbing connection and single point

electrical connection.

Applications

∙ Hot and cold water booster systems

∙ Hot and cold water pressure systems

∙ Submersible pressure systems

∙ General water transfer

∙ Rainwater re-use

∙ Irrigation

Range

∙ Fixed or variable speed

∙ Single and multiple units

∙ Single or multistage pumps

∙ Horizontal or vertical pumps

∙ Fully-manifold systems

∙ Alternative manifold materials:

PE/Poly/Stainless Steel/Copper

PACKAGED PRESSURE SYSTEMS & BOOSTERS

DIESEL & ELECTRIC HYDRANT BOOSTER PUMPS

Kelair offers fully-compliant AS2941, fully-packaged hydrant booster pumps com-

plete will fully-valved suction and discharge manifolds and by-pass line. Packaged

systems provide simple installation. All units are factory tested prior to delivery and

are supported by Kelair’s field service technicians.

∙ Pressure -sustaining relief valves

∙ NFPA 20 & FM-approved versions also available

∙ Annubar test lines

∙ Automatic and manual jacking pumps

∙ On-site commissioning

∙ On-site flow tests

FIRE SPRINKLER PUMPSETS

∙ A complete range of fire sprinkler pumpsets for applications such as high-rise

buildings, low-rise buildings, hospitals, mine sites, industrial factories and pro-

cessing plants.

∙ Units can be supplied to comply with the following standards:

∙ AS2941/AS2118

∙ NFPA20 and FM approved versions also available

∙ ESFR and High-hazard systems

∙ Fully-valved suction and discharge manifolds

∙ Annubar test lines

∙ Pressure sustaining / relief valves

∙ Annubar jacking pumps

∙ On-site commissioning

Building & Fire

‘When Pump Knowledge Matters’ Call 1300 789 466

SEWAGE-STORMWATER-SUBSOIL

FIRE HOSE REEL & JACKING PUMPS

Kelair produces a range of fire hose reel and jacking pumpsets electrically driven and

set for automatic start/stop.

• Compliance with AS2941 available

• Galvanised base frame

• Discharge isolating valve

• Hydro-pneumatic pressure gauge

• Suction check valve

• Special two-way valve

Options: • Weatherproof units

• Flow switch control

• Integrated by-pass pipework and valves

• Inching button

Kelair provides a complete range of submersible pumps in all configurations.

∙Flow range 0.5 l/s to 50 l/s - larger units provided on request

∙Pressure range 5m to 50m

∙Pumps compliant with Class 1 Zone 2.

∙Pedestal-mounted or free-standing

∙Complete fully-packaged units including pipework and valves

∙Single / Dual / Triplex

∙Small domestic and under-sink units

∙Vortex / Cutter / Grinder Impellers

HOT WATER CIRCULATORS

∙ For primary or secondary circulation

∙ Bare pumps or fully piped systems

∙ Wall or floor mount

∙ Wide variety of control panel options

∙ Variable speed drive versions

∙ Choice of bronze or stainless steel

∙ Weatherproof versions

Building & Fire

‘When Pump Knowledge Matters’ Call 1300 789 466

Waste from factories and commercial industries is required to have the grease sepa-

rated before the residue is disposed of into the sewer. Kelair provide fully- approved

units.

∙ Fibreglass / stainless steel construction

∙ Above or below-ground installation

∙ Gravity or pumped systems

∙ Sizes 1000 to 5000 litres

GREASE ARRESTORS

COALESCING PLATE SEPARATORS

Kelair provides fully-approved oil separators (coalescing plate separators) which are

an enhanced gravity separator, capable of removing oil solids or both.

∙ Range from 1000 litres to 3000 litres/per hour

∙ Horizontal units or if space constraints, vertical units

∙ Supply of fully-packaged unit with pump & float switch

∙ Class 1 Zone 2, or Class 1 Zone 1 classification

∙ Water board-approved

∙ Poly / Fibreglass / Stainless Steel construction

∙ Quotes for ongoing maintenance.

∙ Service station forecourts

∙ Washbays

∙ Vehicle detailers

∙ Wrecking yards

∙ Mechanical workshops

∙ Hydrovar variable speed pumps

∙ Submersible pressure pumps

∙ 0.5kW to 20 kW

Rain and stormwater re-use is a cost-effective, environmentally-sound practice and easy to implement. Re-use

systems normally take the form of pressure systems to run irrigation and flush toilets.

Kelair supplies above-ground and submersible pump solutions for rainwater re-use systems. These can incor-

porate primary / secondary filtration and UV sterilisation.

The Kelair rainwater re-use range is a robust industrial-rated solution and includes automatic towns main back

up in the event of power failure, or insufficient rain / stormwater supply or tank refill configuration if required.

Features and Options

∙ 100 kPa to 1000 kPa rated

∙ Single or dual pumps

∙ Above-ground or submersible

∙ Duty / Standby operation

KELAIR RAINWATER RE-USE SYSTEM

Building & Fire

‘When Pump Knowledge Matters’ Call 1300 789 466

CONTAINERISED PRESSURE SYSTEMS & BOOSTERS

CONTAINERISED FIRE PUMP UNITS

Kelair Pumps Australia Pty Ltd A Mace Group Company ABN 28 001 308 381 E-mail: [email protected] www.kelairpumps.com.au

HEAD OFFICE & FACTORY 211-215 Walters Road Arndell Park NSW 2148 Toll-free within Australia 1300 789 466 Ph +612 9678 9466 Fax +612 9678 9455

VIC TAS WA QLD

Fax 03 9768 2907 Fax 03 6331 9102 Fax 08 9248 2255 Fax 07 3805 7309 Brisbane Fax 07 4952 1097 Mackay

PUMPS BUILDING & FIRE ENVIRONMENTAL SERVICE B&FPR-Mar14

Building & Fire

‘When Pump Knowledge Matters’ Call 1300 789 466