Building Automation - Carlo Gavazzi | Automation ...€¦ · energy saving, building owners must...
Transcript of Building Automation - Carlo Gavazzi | Automation ...€¦ · energy saving, building owners must...
Building Automation
Building Automation
Solutions for
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.2
Building AutomationSolutions for
ABOUT CARLO GAVAZZI
Carlo Gavazzi Automation is a multinational electronics group active in the design, manufacture and marketing of electronic equipment targeted at the global markets of industrial and building automation.
Our history is full of firsts and our products are installed in a huge number of applications all over the world. With more than 80 years of successful operation, our experience is unparalleled.
We have our headquarters in Europe and numerous offices around the world.
Our R&D competence centres and production sites are located in Denmark, Italy, Lithuania, Malta and the People’s Republic of China.
We operate worldwide through 22 of our own sales companies and also selected representatives in more than 65 countries, from the United States in the West to the Pacific Rim in the East.
Our core competence in automation spans four product lines: Sensors, Switches, Controls and Fieldbuses.
Our wide array of products includes sensors, monitoring relays, timers, energy management system, solid state relays, safety devices and fieldbus systems.
We focus our expertise on offering state-of-the-art product solutions in selected market segments.
Our customers include original equipment manufacturers of packaging machines, plastic-injection moulding machines, food and beverage production machines, conveying and material handling equipment, door and entrance control systems, lifts and escalators, as well as heating, ventilation and airconditioning devices.
Metering Lightingcontrol
HVACsystems
Integrated solutions
Parking guidance system
Monitoring and protection
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 3
DESIGNED TO MEET MARKET REQUIREMENTS
Building Automation Systems consists of the networking of electronic devices designed to monitor and control the mechanical, security, lighting, HVAC and humidity control and ventilation systems in buildings such as :
• Shopping malls• Offices• Airports• Hospitals• Schools• Carparks• Production facilities• Logistics centres
Commercial Buildings and Infrastructures New energy-efficient buildings and the improvement of existing ones are arguably the most important initiatives we can take to reduce energy consumption and limit CO2 emissions.Energy in these buildings is mainly used for lighting, air-conditioning, ventilation, heating, refrigeration, lifts and motors. The majority of these buildings already exist, so there are great opportunities to improve their energy performance through targeted initiatives, upgrades and retrofitting.To meet the mandatory requirements for energy saving, building owners must comply with efficiency improvement regulations.
Production Facilities and Processes
Predictive maintenance and energy saving are probably the most important issues for improving the efficiency of machinery and reducing overall energy consumption and production downtime.The continuous and efficient operation of equipment is a crucial element in optimising and reducing energy use. In particular, preventing equipment failure through predictive maintenance is very cost effective, both in terms of production output efficiency and in terms of operating costs. High energy users are: motors, electric heaters, lighting systems, air-conditioning units and compressors; all these have to be monitored and optimised in order to reduce energy consumption.
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.4
Building Automation
The accurate measurement of energy consumption is the first step in the collection and analysis of the information required for effective energy management. Information about the quality of the power used can improve on-site efficiency and facilitate troubleshooting in the case of any problem to the electrical installation.
In many commercial buildings the need to control and measure the energy consumption of single users is becoming more important for an accurate cost allocation. Our energy meters and data logging systems provide information so that operators can identify consumption trends and take corrective action.By analysing the energy consumption profile, operators can also aggregate loads and negotiate more favourable tariffs with utility companies. Alarm thresholds can be set to warn if preset limits are reached, so that corrective action can be taken. Real-time power consumption monitoring allows energy managers to anticipate overloads, avoid
Energy meters/analysers
Power quality analysers
Current transformers
Double 3-phase energy meters
Web servers
EM23EM24EM26
WM30WM40
CTDTCD
EM270EM271
VMU-C EMVMU-Y EM Em2-Server
Metering
circuit breaks and not exceed contractual tariffs. You can now monitor in detail each single load of the installation thanks to the new Quick-fit energy meters EM270/271. These meters can manage 2 current inputs, so they can monitor 2 three-phase loads at the same time. Even 3, if we consider that they also include a virtual meter which automatically calculates the sum of the 2 measured loads. In addition, compact 3-phase current transformers contribute to a smart and rational use of the available space in any switch board, while pre-assembled groups of 3 miniature split-core current allows retrofitting in all the more complex situations.
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 5
The use of electricity for lighting obviously has a considerable impact on energy consumption in commercial buildings, infrastructures, production facilities and logistic centres.
In the case of hospitals and airports, or in the case of shiftwork, lighting is used 24 hours per day, all year round, heavily impacting on total consumption. Energy bills can be reduced by installing energy-efficient control systems.Using lighting controls for dimming or turning lights on and off, such as dimmers and luminosity and occupancy sensors, energy efficiency is increased.
• Dimmers reduce the power supplied to the bulbs, limiting consumption and increasing their life cycle.
• Lux sensors dim or turn lights on or off in response to natural lighting levels.
Lighting control
SB2WEB24 SB2DALI230 SHSQP360LSH...P90L
SH...P150/150L
SHG....LS4 SHG....LS6 SHG....SLD B..X-LS4-U
BDB-INCONX-USHPIN
BDA-RE13A-U
• Presence sensors activate lights when a person is in the area and turn the lights off after the person has left.
BACnetcontroller
DALIbus generator
PIR + Luxmeters
Lightswitches
Analogue inputmodules
Decentral output module
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.6
Building Automation
Commercial buildings and infrastructures, production sites and logistics centres, use a large percentage of energy in HVAC systems. This is due to the presence of a large number of people who need to be offered the most comfortable environment.
Most of the motors used in ventilation systems are simply switched on and off with no speed control. Various switching modes are available in the new RGC3P series to cater for different application needs, such as phase angle switching for speed control and light dimming and full cycle
switching for temperature control. The version with soft starting prevents high inrush currents associated with loads which have a high cold/hot resistance ratio. Soft starters control the acceleration and deceleration of motors and compressors, eliminating current peaks and mechanical shocks and increasing the life-span of the equipment. Presence sensors provide zoned temperature control by setting on/off time schedules for the right climate conditions.
HVAC systems
RSBD/RSGDRSBT/RSDR
SHSU....DSHSU....LSHSU....
SHSQP360LSH...P90L
SH...P150/150L
RGC1A/RJ1PRGC2A/RGC3ARGC2P/RGC3P
DPA51DPA53DPB51
EM10/EM11EM210EM21
Softstarters
Environmentalsensors
PIR + Lux meters
Solid staterelays
Monitoring relays
Energy meters/analysers
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 7
SB2WEB24 SB2DALI230 SH...P150/150L SHSQP360LSH...P90L
B..X-LS4-U SHG....LS4 SHG....LS6 SHG....SLD
SHSU....DSHSU....LSHSU....
SHPIN....BDB-INCONX-UBDA-RE13A-U
BACnetcontroller
DALIbus generator
PIR + Luxmeters
Lightswitches
Environmentalsensors
Decentral I/Omodules
Integrated solutions
controller, and every module needs power supply connection. Furthermore, the system provides high flexibility for last minute changes and future enhancements, because the 2-wire cable is already available throughout the installation, so it is easy to add extra modules.
The brain in the system is the SB2WEB BACnet controller, which performs the intelligent functions, and at the same time provides the link to any upper level BMS through BACnet/IP. During configuration, the PC-based programming tool scans the Dupline® network and automatically assigns addresses to all the data points and
creates the relevant BACnet objects. This allows any BACnet compatible DDC controller to use Dupline® as remote I/O by reading and controlling the data points through standard BACnet objects. In the lighting control system, Dupline® is used for presence and movement detectors, lux sensors and light switches etc, while the DALI bus is used for the lighting actuators (ballasts).
The DALI controller is a 2-DIN module, which connects to the Dupline® bus at any point. The SB2WEB provides a range of pre-defined lighting functions, including the much used constant light control.
Carlo Gavazzi’s innovative bus technology, Dupline®, allows system integrators to design and build efficient building automation systems integrating lighting control, HVAC and metering at the field level. The Dupline® bus greatly simplifies the installation and commissioning of a building automation system. Sensors and I/O-modules are bus-powered and designed for de-central installation, hence the cabling is merely a question of multi-dropping the 2-wire bus from module to module. This provides a significant installation cost reduction compared to the traditional star wiring, where every signal needs a wire back to the
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.8
Building Automation
The Parking Guidance System (PGS) is based on Carlo Gavazzi’s expertise in sensing and communication technology within the industrial automation market. Our patented Dupline® 3-wire bus is a tried and tested network with more than 150,000 installations worldwide. The PGS is completely scalable and can be used in any type and size of indoor carpark. In spite of the advanced functions, the system is surprisingly easy to install and configure, providing the detection, counting and indication of vacant spaces. By means of dynamic green arrows, drivers are directed to the closest free parking bay, resulting in considerable time-saving. Our Parking Guidance System not
only provides drivers with more convenience and less stress, but by monitoring the whole situation of the parking area it increases efficiency in car flow, reducing energy costs.Cars can be directed to pre-selected areas of the carpark, while the system ensures that lighting and ventilation systems are disabled in unoccupied zones. Carlo Gavazzi’s product range for carparks, besides the controller, sensors, LED indicators and displays, also includes a series of easy to install ‘loop detectors’. Based on an inductive measurement principle, a coil of wire is buried in the ground, detecting cars driving over it. Typically it is installed in the ground in front of a security
entry gate or to detect the occupancy of outdoor parking bays. In addition to the single space detection system, Carlo Gavazzi also provides a zone count solution. Sensors detect the cars entering and leaving the zones, thereby allowing the master zone counter to keep track of the available spaces and showing them on parking zone displays. Combined single spot and count systems are possible resulting in great advantages. A specific web app has been developed so as to provide an easy remote access to the carpark occupancy data via smart phone and an improved carpark revenue and management via the booking system.
GP32900003 GPMZ-SET GP6220..GP6240..
GP6289..GP6265..
GP676330..GP676301..
DUP-PGS-SW
Parking guidance system
Channel generator
Master zone counter
Ultrasonicsensors
LEDindicator
Carparkdisplays
Carparksoftware
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 9
Good voltage level and stability are fundamental requirements for reliable equipment operation; too low or too high voltage levels could cause failures. It is important to monitor the instant level of voltage as well as voltage sags and transients which may occur over time. In a production facility it is quite common to use and add to electrical loads, especially these with high in-rush current. Voltage sags indicate that a system is not able to respond properly to load requirements, leading to production process interruptions.Monitoring voltage balance in a three-phase power distribution system is crucial for the efficiency of motors and any three-phase load;
an unbalanced supply can cause poor performance of the equipment, leading to premature motor failure due to increased mechanical stress. Controlling harmonic distortion helps prevent failures of critical equipment such as motors and transformers; the main problems caused by harmonics are overheating of motor windings and transformers, higher susceptibility to voltage sags, excessive current to neutral conductors and noise, all of which reduce the lifespan of the equipment. Within our product range, we can offer devices to monitor the correct level of voltage and frequency of single and 3-phase systems. Phase sequence and loss, along with the
voltage, can be detected, notifying the user if a system failure occurs. The voltage level of the start-up battery can also be properly monitored. We can also offer current monitoring devices capable of sending alarm signals when an over-current situation is detected.Our new Surge Prrotection devices can be used in Building Automation applications, in order to protect devices connected to the mains. A special range has been developed for the protection of Dupline® buses as well as for RS485 communication lines.
Power transducers
Current transformers
3-phase monitoring relays
Current monitoring relays
Surge protection
devices
CPT E83A82MP3
DPA51DPA53
DIA53DIA01
DSF A/PDSB A/P
DSB51XXDP
Monitoring and protection
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.10
Building AutomationLighting and environmental control
Dupline®
into a BAS infrastructureDupline®
at a glance
Fiel
dle
vel
Auto
mation
leve
lM
anagem
ent
leve
l
SB2WEBBACnet Controller
EM24
I/O
Main Controller Mobile phone, email
RS485 Dupline®
PIR/LUX CO2/T/%RH Temperaturecontrol
Lightswitch
4 contacts input
•2-wire bus with free topology•Bus-powered sensors and I/O-
modules•Long transmission distance•No need for special cables
(no shield required)•High noise immunity•Easy installation and commissioning•Technology proven in 100.000+
industrial installations•Cost-effective
The Dupline® fieldbus carries out the task to link together all the field level devices in a simple and cost-effective way, and to cetralize the data in the BACnet controller SB2WEB. Any DCC and BMS front end with the capability to act as BACnet client then have access to all the Dupline® data points via the BACnet/IP connection, thereby eliminating the need for hardwired I/O.
The SB2WEB programmable functions include several pre-defined lighting control functions for energy saving, based on presence detection, lux level and dimming of lights via the DALI bus. All of the functions can be controlled and managed via BACnet objects, for example adjusting operating parameters like lux threshold and energy saving timer.
Weatherstation
BACnet is standard communications protocol for building automation and control networks. It is an ASHRAE, ANSI, and ISO standard protocol too.
ASHRAETM
/ Ethernet / Modbus TCP/IPASHRAETM
/ Ethernet / Modbus TCP/IPASHRAETM
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 11
BTM touch screen
Dupline®
benefits
DDC(HVAC Controller)
DALI Controller
Dali BallastDali BallastDali Ballast0 - 10 V output
Relay
Benefits for system integrators•Simplified system design•Easier planning•Reduced installation time•Reduced commissioning time•High flexibility for last minute
changes and system enhancements•Enhanced diagnostic•Reduced cost of implementation
Benefits for building owners•High flexibility for future
enhancements•Reduced maintenance cost•Reduced cost of implementation
BTM touch screen
PIR sensors Light switches
The BTM touch screen is now available with BACnet on board in order to control and visualise any data point with an eye-catching user interface: the whole building is under control just with a fingertip.
In addition, using the new KNX plug-in module, the BTM becomes the perfect gateway to integrate Carlo Gavazzi’s home and building automation system with the KNX products.
/ Ethernet / Modbus TCP/IPASHRAETM
/ Ethernet / Modbus TCP/IPASHRAETM
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.12
Building AutomationEnergy efficiency monitoring
VMU-C EM into an Energy Monitoring architecture
VMU-C EM at a glance
Met
er
leve
lW
eb-s
erve
r and G
ate
way
leve
l
Clo
ud a
nd
Serv
er lev
el FTP protocol
Site 1
RS485 protocol
HTTP protocol
•No crash or compatibility problems due to different operative systems, different languages, libraries, etc.
• Improved IT security •Application-focused software
embedded inside industrial grade hardware: no need for a dedicated PC for monitoring
•On-site database•Polling device, data-logger and
Ethernet gateway in a single compact unit
•Modular solution for additional inputs/outputs
•Optional modular modem for wireless Ethernet connections
•Scalability to multi-site applications by means of VMU-Y + Em2-Server solutions
The VMU-C EM is the core solution for effective Energy Monitoring in applications of all sizes. It collects measurements from energy meters through the fieldbus; it stores information (variables and alarms) in its local database and displays it through its web-based graphical user interface.The whole system set-up and operation is possible via the VMU-C’s web interface, without any external software.The VMU-C EM can exchange data with other systems by means of standard FTP/HTTP communication. Multi-site applications can be managed by adding either the Em2-Server or the VMU-Y EM to the VMU-C EM powered installations.
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 13
Em2-Server multi-site cloud solution at a glance
VMU-Y EM multi-site solution at a glance
Site 2 Site 3 Site 4Zone1
Site 4Zone2
RS485 protocol
•Multi-site management software embedded in compact hardware
•Plug and play operation and set-up •Reliable data communication with
VMU-C EM•Up to 10 geographically different
sites can be managed with a single unit
•A single supplier for energy meters, gateways and data management solutions
•Multi-site management software based on Virtual Machine concept
•Flexible operation and set-up •Reliable data communication with
VMU-C EM•Up to 100 geographically different
sites can be managed with a single unit
•A single supplier for energy meters, gateways and data management solutions
•Scalable solution
VMU-YEm2-Server
Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.14
Our product rangeOur product range
SB2WEB24
• Multi-protocoldevice• Flexible modular plug-in concept forDupline®busdrivers
• Managesupto7Dupline®Bussegments• Connects directly to Energy MetersviaModbusRS485
• Any data point and internal valueavailableasBACnetobject
MAIN FEATURES• Easyandfastconfiguration• Dimensions:2-DINmodules• DCpowersupply
BACnet controller
SH2MCG24
• Connection toSH2WEB24via internalbusorterminalsviathehighspeedbus
• Upto7SH2MCG24canbeconnectedon the samenetwork, considering thesumofSH2MCG24andSH2WBU24
MAIN FEATURES• Dimensions:2-DINmodules• DCpowersupply
Wired busgenerator
SH2SSTRI424
• 4triacoutput• Moduleload:4x10W• LED-indications for supply, bus andoutputsstatus
• Connectiontoothercabinetmodulesvialocalbus
• Pushbuttonforlocalon/offswitching
MAIN FEATURES• Dimensions:2-DINmodules• DCpowersupply
Output module Solid state relay
SH2RE16A4
• 4separateoutputsrelay• LED-indications for supply, bus andoutputsstatus
• Connectiontoothercabinetmodulesvialocalbus
• Pushbuttonforlocalon/offswitching
MAIN FEATURES• Dimensions:2-DINmodules• Bussupplied
Relaymodule
SH2RE16A2E230
• 2outputsrelay• Energyreading• LED-indications for supply, bus andoutputsstatus
• Connectiontoothercabinetmodulesvialocalbus
• Pushbuttonforlocalon/offswitching
MAIN FEATURES• Dimensions:2-DINmodules• 230Vsupplied
Relay module with energy reading
SB2DALI230
• InterfacestheDupline®bustostandardDALIlightingactuators
• OperatesasDALI controllerandpowersupplywithpossibilitytoconnectupto64ballaststotheDALIbusoutput
• CanbelinkedtoDupline®atanypointintheinstallation
• Multiple SB2DALI230 units can beconnectedtothesameDupline®bus
MAIN FEATURES• Allows the powerful combination ofDupline®andDALI
• Compactdimension:2-DINmodule• 230VACpowersupply
DALIbus generator
SH2ROAC224
• Up/down control of 2 AC rollerblindmotors
• LEDindicationforpowersupply,duplinebus,motorup,motordown
• Connectiontoothercabinetmodulesvialocalbus
• Pushbuttonforlocalon/offswitching
MAIN FEATURES• Dimensions:2-DINmodules• DCpowersupply
Up/down control for AC motor
SH2INDI424
• 4digitalinputsNPN,PNP,voltagefree• The 4 inputs can be configured ascontactorcounter
• LEDindicationforpowersupply,duplinebus,inputactivated
• Connectiontoothercabinetmodulesvialocalbus
MAIN FEATURES• Dimensions:2-DINmodules• DCpowersupply
Digital input module 4 inputs
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 15
Our product range
SHPINA224 SHPINV324 SHPINV2T1P124
• Ranges:0-10V,0-20mA,4-20mA• 24VDCpowered• Smalldimension
MAIN FEATURES• Small dimension makes it easy toinstalldecentrally
• SHPINV324:3x0-10Vinputs• SHPINA224: 2 x 0-20 mA /4-20 mA inputs (configurable)SHPINV2T1P124: 2 x 0-10V + 1 x10K3+1x1-11Kinputs
Analogue input modules
BDA-RE13A-U
• Smallsizedsinglerelayoutput• Load:16A/250VAC• Withstands130Ainrushcurrent
MAIN FEATURES• Buspowered
Decentral outputmodule
SB2REP230
• RegeneratestheDupline®carriersignal• Outputcurrentloadupto300mA• Extendsnetworklenght• Isolates the primary and secondaryDupline®
• 230VACpowersupply
MAIN FEATURES• Extendsthelenghtofthebuscable• 230 VAC power supply suitable fordecentralinstallation
• Compact2-Dinhousing
Repeater module
BDB-INCONx-UBDB-IOCP8x-U
• Small-sized4or8I/Omodules• 4or8contactinputsforpushbuttons
MAIN FEATURES• Compacthousing• Buspowered
Light switchinterface
BDA-INVOL-U
• Input voltage module for buildingautomation
• 1 opto-isolated voltage input 90-265VAC
MAIN FEATURES• Compacthousing• Buspowered
Voltage inputmodule
SHDRODC230
• AC powered small dimension 2 x 5 Arelay output for control of roller blindmotor
• Relay interlock function for roller blindmotorprotection
• cULapproved
MAIN FEATURES• Designformountingineurobox• Relayload5A
Up/down control for DC motor
SH2D500W1230
• UniversaldimmerswitchforR,L,Cupto500WandLEDloads
• Integrated heat sink for temperaturedissipation
• AutomaticloaddetectionforL,R,Cload• Connectiontoothercabinetmodulesvialocalbus
• Pushbuttonforlocalon/offswitching
MAIN FEATURES• Dimensions:2-DINmodules• 230Vsupplied
Dimmer module up to 500 W
SH2D10V424
• Switching and dimming adjustableballasts1to10V
• 4independentdimmableoutputs• LED-indications for supply, bus andoutputsstatus
• Connectiontoothercabinetmodulesvialocalbus
• Pushbuttonforlocalon/offswitching
MAIN FEATURES• Dimensions:2-DINmodules• DCpowersupply
Dimmer module 1-10 V
Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.16
Our product range
B4X-LS4-UB5X-LS4-U
•4 individually programmable pushbuttoninputs
•4 individually programmable LEDs fortrueresponse
• Bus powered, no external supplyrequired
MAIN FEATURES• B4X-LS4-U: Developed to fit into wallsocket and frames from Fuga, NIKOandBticino
• B5X-LS4-U: Developed to fit into wallsocketandframesfromElko,GiraandJung
Light switches
SH..XP150/150L
• Passiveinfrareddetector(PIR)• Detectsmovementandpresence• Indoorandoutdoorapplications• Operatingangle:150°• Lightingmeasuringrange:0to20Klux
MAIN FEATURES• Buspowered• Walktest:LEDindication• Programmablesensitivity
150° PIR + Lux meter
SHG060BSLT SHG060WSLTSHG503BSLT SHG503WSLT
• Itcancontrolonetemperaturefunctionmanaging 3 setpoints with the sliderandon/offfunctions
• Integrated temperature sensor, range-9°to50°C
• Whiteandblackglass• BacklightONwhenthehandnearstheglass• Programmablebuzzerwhenakeyispressed• Showscurrentroomtemperatureandasecondarytemperature
MAIN FEATURES• Powersupply:24VDC• Mounting:503box,Ø60box
Glass touchtemperature
SHG060WLS4 SHG060BLS4 SHG503WLS6 SHG503BLS6
•4or6individuallyprogrammablekeys• Blackorwhiteglass• BacklightONwhenthehandnearstheglass
• Programmable buzzer when a key ispressed
• Integrated temperature sensor, range-9°to50°C
MAIN FEATURES• Powersupply:24VDC• Mounting:503box,Ø60box
Glass touch switches
SHG060BSLD SHG060WSLDSHG503BSLD SHG503WSLD
• 4dimmableoutputsoron/offfunctions.The push buttons can be programmedtocontrolupto
• The dimming level is changed bymovingthefingerovertheslider
• Blackorwhiteglass• BacklightONwhenthehandnearstheglass
• Programmable buzzer when a key ispressed
MAIN FEATURES• Powersupply:24VDC• Mounting:503box,Ø60box
Glass touch dimming
SHPINCNT4 SHPINCNTS04
• Pulsecountermodulewith4inputs• AvailablewithstandardS04inputsandlowcurrentinputs
• The count values are stored in non-volatilememoryonboard
• Inputcountfrequencyupto100Hz• Inputs can also be used as digitalcontactinputs
MAIN FEATURES• Small dimension makes it easy toinstallwithexistingmeters
• Buspowered,sono localpowersupplyneeded
• Option for count reset via SmartDupline®
Pulse counter modules
SHPOUTV224
• Output modules with two 0-10 Voutputs
• Small dimensions for decentralizedinstallations
MAIN FEATURES• DCpowersupply
Analogue outputmodule
SHPINNI2 SHPINT1P1
• Ranges: Pt1000, Ni1000, 10K3thermistor,1-11Kpotentiometer
• Bus-powered• Smalldimension
MAIN FEATURES• Small dimension makes it easy toinstallwithexistingmeters
• Buspowered,sono localpowersupplyneeded
• OptionforcountresetviaSmartDupline
Temperature resistor input modules
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 17
Our product range
SHA4XLS4THSHE5XLS4TH
• 4 individually programmable pushbutton
• Integrated temperature and humiditysensor
• Temperaturerange:-40°to60°C• Humidityrange:5to95%
MAIN FEATURES• SHA4XLS4TH:DevelopedtofitintowallsocketandframesfromFuga,NIKOandBticino
• SHE5XLS4TH:DevelopedtofitintowallsocketandframesfromElko,GiraandJung
Light switch + temperature and humidity sensor
SHA4XTEMDISSHE5XTEMDIS
• Temperaturecontrollerwithdisplay• Shows current room, outdoor andauxiliarytemperature
• Turnson/offheatingandcooling• Energy Save through 3 differentsetpoints:comfort,activity,economy
MAIN FEATURES• Buspowered• SHA:Developed tofit intowall socketfromFuga,NICOanBticino
• SHE:Developed tofit intowall socketfromElko,GiraandJung
Temperature displays
BSH-LUX-U
• Lightingmeasuringrange:0to20Klux• Forindoorandoutdoorinstallation• Workingtemperature:-30°to+60°C
MAIN FEATURES• Easilymountable• Buspowered
Lux meter for outdoor installation
SHSU....DSHSU....LSHSU....
• RoomsensorsforCO2,temperatureandhumiditymeasurement
• Availablewithdisplay,RGBLEDorneutral• Temperaturerange:-20°Cto+50°C• Humidityrange:0to100%RH• CO2range:0to2000ppm
MAIN FEATURES• Easilymountable• Buspowered• Lowcurrentconsumption
Environmentalsensors
SHA4XP90L / SHE5XP90LSHSDP90L / SHSBP90LSHSPP90L / SHSQP360L
• Passiveinfrareddetector(PIR)• Detectsmovementandpresence• Indoorandoutdoorapplications• Operatingangle:90°and360°• Lightingmeasuringrange:0to20Klux
MAIN FEATURES• Buspowered• Walktest:LEDindication• Programmablesensitivity
PIR + Lux meters
SHOWEAGPS
• Light,wind,temperaturemeasurement• Ranges:0to100Klux,0to35m/s,-40°to80°C
• Rainsensorincluded
MAIN FEATURES• IntegratedGPSreceiver• ModbusRS485protocol
Weatherstation
BTM-T4-24
• 4’’colourdisplay• Easy setup of graphic pages andfunctions with the powerful softwareWizard
• Activation of internet links throughtouchbuttons
• SupportviewingfromIPcamerasMAIN FEATURES• Ethernetconnection• BACnetprotocolavailable• USB port, SD memory, Modbus RTUserialport
• KNXcompatibilityplug-in
Touch screen/data logger
BTM-T7-24
• 7’’colourdisplay• Easy setup of graphic pages andfunctions with the powerful softwareWizard
• Activation of internet links throughtouchbuttons
• SupportviewingfromIPcamerasMAIN FEATURES• Ethernetconnection• BACnetprotocolavailable• USB port, SD memory, Modbus RTUserialport
• KNXcompatibilityplug-in
Touch screen/data logger
Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.18
Our product range
EM23 DIN, EM24 DIN
• Single-phase and 3-phase energymeterswithdirectconnection
• Currentratesupto65A• 1 or 4 DIN rail housing dimensions(EM23andEM24)
• Class1(kWh)acc.toEN62053-1• Pulseopencollectoroutput• Modbusconectionport(EM24)
MAIN FEATURES• Directmeasurementinaverycompacthousingtosavespace
• Enables and simplifies energy costallocation
• MIDAnnexDcertificationavailable
3-phase energy meters/analysers
EM10 DIN / EM11 DIN
• Energymeterswithdirectconnection• Currentinputupto32A• 1DINmoduledimension• Class1(kWh)acc.toEN62053-1• Pulseopencollectoroutput
MAIN FEATURES• Directmeasurementinaverycompacthousingtosavespace
• Suitabletomeasuregeneratedenergy• MIDAnnexDcertificationavailable
1-phase energy meters
CGESAIRVEL
• AirVelocitysensor• Ductmounting• Workingrange0...10/15/20m/s• Outputs:0-10V;4-20mA;• Supplyvoltage:24VAC/DC
MAIN FEATURES• Lowangulardependence• Verygoodaccuracyatlowairvelocity• Plug&Play:nosettingsneeded
Environmental sensorsair velocity
BSI-TEMANAx-U
• Temperaturerange:-40°to+60°C• BSI-TEMANA-UisdeliveredwithaM12plug
• BSI-TEMANAB-U is deliveredwith 2mcable
MAIN FEATURES• Easilymountable• Buspowered
Outdoortemperature sensor
EM21 72D
• Dimensions:4DINmodulesor72x72mm• Installation:DIN-railorpanelmountinginasingleproduct
• 3-phaseenergymeterswithCT/VTconnection• Measurement of voltage, current,power,powerfactorandfrequency
• Self-powered• Pulseoutput• RS485ModbusRTU
MAIN FEATURES• CE,cULus• MIDAnnexDcertificationavailable• Sealableterminalcovers• Verycompacthousingtosavespace
3-phase energy analyser
EM210 72D
• Dimensions:4DINmodulesor72x72mm• Installation:DIN-railorpanelmountinginasingleproduct
• 3-phase energy meters with CT/VTconnection
• Measurement of voltage, current,power,powerfactorandfrequency
• Self-powered• Pulseoutput• RS485 Modbus RTU, high speed(upto115kbps)
MAIN FEATURES• CE,cULus• Sealableterminalcovers• Verycompacthousingtosavespace
3-phase energy analyser
CGESC02
• CO2sensor• Ductandwallmounting• Workingrange0-2000ppm/0-5000ppm
• 3outputs:0-10V;4-20mA;switchingoutput
• Supplyvoltage:24VAC/DC
MAIN FEATURES• High accuracy ±50 ppm (+2%) at2000ppm
• Auto-calibration• Plug&Play:nosettingsneeded
Environmental sensorsCO2
CGESHT
• Relative Humidity and Temperaturesensor
• Ductandwallmounting• Workingrange0...95%RH;0...50°C
• 2outputs:0-10V;4-20mA;Supplyvoltage:24VAC/DC
MAIN FEATURES• Differentprobelength• Display• Plug&Play:nosettingsneeded
Environmental sensorshumidity and temp.
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 19
Our product range
VMU-C EM
• Micro PC with Web-server and Webservicecapability
• Dataandeventloggingcapability• Internal4GBmemoryand16GBSDHCcardback-upmemory
• Variablesshownasgraphsandnumbersinformattedtables
• AlldataexportsonHTMLformatcompatiblewithExcelorotherspreadsheets
• Management up to32energymetersand11remoteI/Omodulegroups
MAIN FEATURES• Energyanalysisofeachsingleload• Energybillevaluation• Virtualmainmeter• Alarmscontrolwithautomatice-mailingandSMSmanagement
Web server and data logger
VMU-W
• Internet access point when regularwirednetworkisnotavailable
• Mobile modem: GSM, GPRS, EDGE,UMTS,HSPA
• Dimensions:2DINmodules
MAIN FEATURES• Suitable for use in combination withVMU-C
• Automaticdualorquadbandsetting(850-900Mhz,1800-1900/2100Mhz)
3G modem for VMU-C EM
WM30 96
• Dimensions: 96 x 96 mm panelmountinghousing.
• Accuracy0.2%(voltage,current)• Universalpowersupply• FrontprotectiondegreeIP65,NEMA4X,NEMA12
• cULusapproved
MAIN FEATURES• ProvidesinstallationdatatoaSCADAtomanagethewholesystem
• Modularhousingtobuildtheinstrumentaccordingtotherealapplicationneeds
• Modbus, Ethernet and BACnet-IPcommunicationportsavailable
3-phase power quality analyser
WM40 96
• Dimensions: 96 x 96 mm panelmountinghousing.
• Accuracy0.2%(voltage,current)• Universalpowersupply• FrontprotectiondegreeIP65,NEMA4X,NEMA12
• cULusapproved
MAIN FEATURES• Built-in datalogger for instantaneousvariables,dmdprofilesandevents
• Modularhousingtobuildtheinstrumentaccordingtotherealapplicationneeds
• Modbus, Ethernet and BACnet-IPcommunicationportsavailable
3-phase power quality analyser
EM26 96
•3-phase energy meters with CT/VTconnection
• Primarycurrentinput:5A•96 x 96 mm housing dimensions,only45mmbehindthepanel
• Class1(kWh)acc.toEN62053-1•Modbuscommunicationport
MAIN FEATURES• Energy analyser in a very compacthousingtosavespace
• Suitable to measure generated andconsumedenergy
• MIDAnnexDcertificationavailable
3-phase energy analyser
EM270 + TCD X
• Triple3-phaseenergymeter• CurrentmeasurementbytripleCTsolidcore
• Dimensions: 4-DIN rail module or72x72mmhousing
• Equivalenttoclass1(kWh)• Twopulseopencollectorsandserial• RS485outputs
MAIN FEATURES• Save90%oftheinstallationtime• Voltage and serial bus daisy chaininstallation
• Fastanderror-proofCTconnectionwithCTratioself-recognising
Double 3-phase energy meter
EM271 + TCD M
• Triple3-phaseenergymeterforretrofit• CurrentmeasurementbytripleCTsplit-corewithRJplug
• Dimensions: 4-DIN rail module or72x72mmhousing
• Equivalenttoclass1(kWh)• Twopulseopencollectorsandserial• RS485outputs
MAIN FEATURES• Save90%oftheinstallationtime• Voltage and serial bus daisy chaininstallation
• Fastanderror-proofCTconnectionwithCTratioself-recognising
Double 3-phase energy meter
VMU-Y EM
• 2-DINsize;DIN-railmounting• Multi-sitemonitoringmanagement• Powersupply24VDC(±20%)• 2USBports(data/connectionbackup)• 1SDport(backup)
MAIN FEATURES• Loadprofilemanagement• Dataanalysisandbenchmark• Dataandeventlogging• Customizablegraphicalsynoptic• AlldataexportedinformatcompatiblewithExcelorotherspreadsheets
• Tariffs,contracts,alarmsmanagement• Database replication from up to 10VMU-CEM
Embedded aggregation server
Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.20
Our product range
CTV
• Split-corecurrentsensors• Primarycurrents:60to800A• Secondaryoutput:0.333VAC• Accuracyclass:1• CE,cURusapproved
MAIN FEATURES• Verycompactsplit-coresensorsidealforretrofitapplications
• SuitableforusewithEM21-72Venergymeter
Current sensors
E83
• Dimensions:56x22.5x49mm• 7inputranges• Ouput4-20mADC• Nopowersupply• UL,CSAapproved
MAIN FEATURES• EasyinterfacetoPLC• Builtinhallsensorforcurrentsensing• LEDindication
AC Currenttransformer
DIA53
• Dimensions: 81 x 17.5 x 67.2 mmDIN-rail housingwith12mmhole forcurrentmeasurement
• Current monitoring relay with built.incurrenttransformer
• 20A,50Aor100Afullscale• Selfpowered• UL-CSA-CCCapproved
MAIN FEATURES• Only2wiresconnection• Adjustablecurrenttrippingsetpoint• IntegratedsolidstateNPNPNPoutput
Current monitoring relay
CPT DIN
• Dimensions: 83.5 x 45 x 98.5 mmDINrailhousing
• Accuracy0.5%(voltage,current)• MeasurementbyCTandVT• FrontprotectiondegreeIP20• Analogue,digital,pulseorserialoutputsavailable
MAIN FEATURES• Verycompactsizepowertransducer• ProvideselectricalvariablessettoaPLCtomanagecompressorsandotherloads
• Suitableforon-boardpanelinstallation
Power transducers
TCD M
• TripleCTforEM271• 4maxcurrentranges:60,100,200,400A
• Holediameters:9.6,15.5,15.5,20.5mm
• Equivalenttoclass1(A)
MAIN FEATURES• Idealforretrofitapplications• ConnectionboxofthesensorforpanelandDIN-railmounting
• Fast installationbyRJ11plugwithCTratioself-recognising
Triple currenttransformers
TCD X
• TripleCTforEM270• 3currentranges:160,250,630A• Holecentres:25,35,45mm• Equivalenttoclass0,5(A)
MAIN FEATURES• Dimensions compatible with MouldedCaseCircuitBreakers
• Forbus-bar,panelandDIN-railmountingwithincludedaccessories
• Fast installationbyRJ11plugwithCTratioself-recognising
Triple currenttransformers
Em2-Server
•Softwareforenergydatamanagement•Multi-sitemonitoringmanagement•Flexibleandscalablearchitecture•VMware®technologycompatibility
MAIN FEATURES• Loadprofilemanagement• Dataanalysisandbenchmark• Dataandeventlogging• Customizablegraphicalsynoptic• AlldataexportedinformatcompatiblewithExcelorotherspreadsheets
• Tariffsandcontractmanagement• Alarmsmanagement• Database replication from up to 100VMU-CEM
Cloud multi-site aggregation server
CTD / TADK
• CTD: currents from 40 to 4000 ATADK2:1-250A
• Removablepanelfixingclips• DIN-railandpanelmountingfacility(TAD...)• Doublescrewterminals(CTD)• Sealablecovers• Case:ABS,self-extinguishinglevelUL94V-O• Accuracyclass:0.5
MAIN FEATURES• Woundprimary/solidcoreorsplit-core• Compliance with IEC 60185, VDE0414-1regulations
• RemovableDIN-railmountingholder
Current transformers
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 21
Our product range
DPA51 / DPA53
• Dimensions 81 x 17,5 x 67,2 mmDIN-railhousing
• Phasesequenceandlossrelay• 3 phase AC (own power supply);regeneratedvoltage
• Powersupplyfrom208to480VAC• Undervoltagedetection• CE,UL,CSAandCCCapproved
MAIN FEATURES• Compressor protection from reverserunningandphaseloss
• 17.5 mm width: the smallest in themarket
• Plugandplay:nosettingsneeded
3-phase monitoring relay
DSF A/P
• Suitable for all single phase (A) andthreephase(P)utilities
• Available for MCOV 300 V, 385 V,460Vand550V
• 20kAInom,40kAImaxperpole• Dinrailmoutingsocket• CE, UL and CSA. Category IEC / ENClassII/Type2
MAIN FEATURES• Optionalremotemonitoringcontact• Patented topology, no backup fuserequired
• Socketwithreplaceablecartridge
3-phase surge protection device
DSB A/P
• Suitable for all single phase (A) andthreephase(P)utilities
• Availablefor275V,385Vand440V• 20kAInom,40kAImaxperpole• Dinrailmoutingsocket• CE,CategoryIEC/ENClassII/Type2
MAIN FEATURES• Optionalremotemonitoringcontact• 3MOVstopology• Socketwithreplaceablecartridge
3-phase surge protection device
DSB51XXDP
• Dimensions90x12x71.5mmDIN-railhousing
• 15Vdcnominalvoltage• 10kAInom,20kAImax• Ratedsparkovervoltage184Vto276V• C1/C2/C3accordingtoIEC61643-21
MAIN FEATURES• Designed for Dupline® communicationlines
• ThreestagetopologywithdualGDT• Socketwithreplaceablecartridge
Dupline® surge protection device
DPB51
• Dimensions: 81 x 17,5 x 67,2 mmDIN-railhousing
• TRMS 3-phase over/under voltage,phasesequenceandloss
• 3 phase AC (own power supply);regeneratedvoltage
• Powersupply208to480VAC• Undervoltagedetection• ULandCSAapproved
MAIN FEATURES• Compressors protection from reverserunningandphaseloss
• DetectsL-LandL-Nvoltage• Independentvoltagesetpointsandbuilt-indelays
3-phase monitoring relay
DIA01
• Dimensions: 80 x 22.5 x 99.5 mmDIN-railhousing
• CurrentmeasurementbyinternalshuntsorexternalCT
• 5Afullscale• 24/48VAC/DCor115/230VAC• UL-CSA-CCCapproved
MAIN FEATURES• Latchandadjustablehysteresis• Adjustablecurrenttrippingsetpoint• 8ASPDTrelayoutput
Current monitoring relay
RSBD / RSBT
• Enhanced current reduction capabilitywithpatentedauto-adaptivealgorithm
• Integrated advanced diagnosticfunctions
• 2-phase (RSBD) and 3-phase (RSBT)controlled and internally bypassedsolutions
• Topoframpandalarmrelayindication
MAIN FEATURES• Noexternalsettingsrequired• Mutli-voltage operation: 220-480 VAC50/60Hz
• Operationalcurrent:55/70/95AAC• Internallysupplied
3-phase scroll compressor soft starters
RSBD / RSBT Modbus
• Modbus RTU over RS485 serialcommunication
• Usersettabledeviceaddress:1-247• Enhanced current reduction capabilitywithpatentedauto-adaptivealgorithm.
• cULus
MAIN FEATURES• Communication of instantaneousvariables(current,voltage,kWh,powerfactor)
• Remotestart/stopviaModbus• Alarm discrimination for quicker faultdiagnosis
3-phase scroll compressor soft starters
Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.22
Our product range
GP6289000x724
• External LED indicator for ultrasonicsensor
• 2-colour LED indication (red/green ,red/blue)
• Controlled directly from carpark sensorG62402224724output
• Lowpowerconsumption• Protectedagainstdustandmoisture• cULapproved
MAIN FEATURES• Fast and easywiring through push-wireconnectors
• Easymountingonceilingorcabletray• Clearandbrightindicationforthedrivers
2-colour LED indicator
GP62xxxxxx724
• Ultrasonicsensorfordetectionofcars• Optionforbuilt-in2-colourLEDindication(red/green,red/blue)
• Optionforbuilt-inbus-controlled3-colourLEDindication(red/green/amber,red/green/blue,red/blue/amber)
• Option to use external LED indicator(2-colouror3-colour)
• PowerandcommunicationviaDupline3-wirebus• Protectedagainstdustandmoisture• cULapprovedMAIN FEATURES• Fastandeasywiringthroughpush-wireconnectors
• Built-intemperaturecompensation• Extremelyhighdetectionaccuracy
Ultrasonic sensor
RGC2A / RGC3A
• Productwidth 54mm up to 70mm,DINmount
• Rated operational voltage: up to 660VAC
• Rated current: up to 75 AAC/pole(RGC2A), 65 AAC/pole (RGC3A) @40°C
• Control input: 5-32VDC,20-275VAC(24-190VDC)
• CE-cULusMAIN FEATURES• Integratedoutputovervoltageprotection• Optional monitoring for SSR and loadcircuitmalfunction(RGC..M)
• 100kAshortcircuitcurrentrating
3-phase solid state contactors
RJ1P
• Dimensions: 81.7 x 45 x 107 mm,DINmount
• Rated operational voltage: up to 660VAC
• Ratedcurrent:upto50AAC@25°C• Controlinput:4-20mA,0-10V• CE-cURus
MAIN FEATURES• Integratedheatsink• Phase angle or Distributed full cycleswitching
• Optionalovetemperatureprotection
1-phase proportional controllers
3-phase proportional controllers
RGC2P / RGC3P
• Product width 54 mm up to 70 mm,DINmount
• Ratedoperationalvoltage:180-660VAC• Rated current: up to 75 AAC/pole(RGC2P), 65 AAC/pole (RGC3P) @40°C
• Control input: 0-20mA, 4-20mA, 12-20mA,0-10V,0-5V,1-5V, externalpotentiometer
• CE-cULusMAIN FEATURES• Integratedoutputovervoltageprotection• Phaseangle,DistributedfullcycleorSoftstartasswitchingmodes
• IntegratedmonitoringforSSRandloadcircuitmalfunction
RGC1A
• Productwidth17.5mmupto70mm,DINmount
• Rated operational voltage: up to 660VAC
• Ratedcurrent:upto85AAC@40°C• Control input: 4-32VDC,20-275VAC(24-190VDC)
• CE-cULus-VDE-GL(upto30AAC)
MAIN FEATURES• Integratedheatsink• 100kAshortcircuitcurrentrating• Optionalovertemperatureprotection
1-phase solid state contactors
RSGD 45mm
• Operational voltage range: 187 - 440VAC,187-660VAC
• Operationalcurrentrange:12AACupto45AAC
• Control voltage : 24 VAC/DC, 110 -400VAC
• Auxiliary relays for top of ramp andalarms
• cULus,CCC
MAIN FEATURES• Compact dimensions: up to22 kW in45mmwidehousing
• Easytosetup:standard3-knobsetting• Internallybypassedandsupplied
22 kW compact motor soft starters
RSWT
• Motorrating:Upto30kW(55A)• 3-phasecontrolled&internallybypassed• Ramp-up/Ramp-downtime:upto20sec• Operationalvoltage:RSWT40:220-400VACRSWT60:220-600VAC
• PTC input, Alarm - Top of Ramp - Runrelayindication
MAIN FEATURES• Easytouseandsetup• Self-learning algorithm to improvepumpstarts/stops
• Integrated overload protection(Class10)
3-phase centrifugal pump soft starters
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only. 23
Our product range
GP6265230x724
• External 3-colour LED indication(red/green/amber, red/green/blue,red/blue/amber)
• PowerandcontrolofcolourviaDupline3-wirebus
• LED colour can be controlled from PCsoftwareorController
• Protectedagainstdustandmoisture• cULapproved
MAIN FEATURES• Possibility to indicate space status(e.g.booked,timeexceededetc.)
• Possibility to install external indicatorsinonelongbus-linealongthelane
• Clearandbrightindicationforthedrivers
Bus-controlled 3-colour LED indicator
DUP-PGS-SWxxxx
• MonitorsallspacesinthePGScontinuously• Graphicaloverviewofthestatusofthespacesintheparkingfacility
• Bar graphs and trend curves for occu-pancyratesinthedifferentareas
• Loggingofallparkingincidentstopro-videpossibilityforhistoricalanalyzes
• Monitoring and logging of alarms like “ex-ceededparkingtime”,“areaalmostfull”etc.
MAIN FEATURES• Real-time overview for the parkingoperators
• Analysisofhistoricaldata foroptimizedcarparkperformance
• Booking feature with easy selection oftherelevantspaces
Carpark software
GP32900003
• Channel generator for the Dupline®3-wirebusinzonecountsystems
• 24VDCPowerSupply• Connect up to 120 count sensors viaDupline®L13-wirebus
MAIN FEATURES• Provides power supply andcommunication line for the carparksensorsandmonitors
Channel generator
GP34960005700
• Driver of power and communicationfor one bus segment with up to120sensors
• Poweredfrom28VDC• Modbus-RTU communication overRS485 / TCP with server runningsoftware
• DIN-railmounting• cULapproved
MAIN FEATURES• Requiredtocreateabussegment• Highcurrentdrivecapability• Freetopologywiringofthebus
Dupline® master module
GP34829091724
• Programmabledeviceformonitoringofseveralspaces
• Controls carpark displays via RS485connection
• Slave mode for local segmentmonitoring, master mode for areamonitoring
• DIN-railmounting• cULapproved
MAIN FEATURES• Easyprogrammingviahandheldtool• Upto480slaveunitsinonesystem• Possibility to enter offset value fordisplay
Carpark monitor
GP32950030700
• ControllerintheDupline®zonecountingsystem• MicroLinuxPCwithEthernetportandWeb-server
• Managesupto3840parkingspacesinmultiplezones
• Eachzonecanhavemultipleentryandexitpoints
• Easyconfiguration,monitoringandcountadjustmentviaweb-server
MAIN FEATURES• Mixed systemswithzone countingandsinglespacedetectionpossible
• Optiontodetectthesplitbetweenhandi-capandstandardspacesoccupancy
• Requires 2 pcs GP32900003700forexternalbusconnection
Count module
GPMZC-SET
• Complete set of cabinet modulesrequiredforzonecounting
MAIN FEATURES• Dupline® ultrasonic sensors, loopdetectors or photoelectric sensors canbeused
• Mixedsystemswithzonecountingandsinglespacedetectionpossible
Master zone counter
GP73800080
• Handheld programmer for sensors andCarparkMonitors
• Used to enter device addresses andoperationmodes
• Can be used as test unit to monitorstatusofspaces
• Used to trigger global calibration ofsensors
• BatterypoweredMAIN FEATURES• Easytouse• Programmerandtestunitinonedevice• Possibilitytosimulatesensors
Carpark programmer
Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.24
Our product range
SPM
• DINrailhousing• Universal input 90-264 VAC / 120-370VDC
• Single phase and battery chargerversionsavailable
• Approvals/Marks: UL, cUL listed andTÜV/CEapproved
MAIN FEATURES• Operating temperature w/o derating-25°Cto+60°C
• ShortcircuitandOverloadprotection• Highefficiency(upto89%)
Switchingpower supply
Switchingpower supply
SPPC 150 • ACinputselectablebyswitch• Inputvoltagerange:88VAC~132VAC/176VAC~264VAC
• Outputprotections:OLP/OVP/SCP• Wideoperatingtemperature(-25°Cto70°C)
• 105Clonglifeelectrolyticcapacitors
MAIN FEATURES• Competitivepriceandcompactsize• DCoutput:5,12,15,24and48V• Goodefficiencyandhighreliability
Switching power supply with PFC
SPPC 150 F • Universal inputvoltage range:85VAC~264VAC/120VDC~370VDC
• Highreliability• Outputprotections:OLP/OVP/SCP• 105Clonglifeelectrolyticcapacitors• 100%fullloadburn-intest
MAIN FEATURES• Built-in active PFC (Power Factor
Correction) function:PF>0.98@115VACandPF>0.95@230VAC
• Competitivepriceandcompactsize• DCoutput:5,12,15,24and48V• Highefficiency(typ):82%-87%
SPUC
• Upto30AUPScontroller• 12Vand24Vversions• OutputsforDeviceOK,BatteryOKandbatteryLow.
• DIN rail battery accessory availableupto7.2A/h
• CEandULapproved
MAIN FEATURES• Tobeusedinadditionwith12or24Vpowersupply
• Front30Areplaceablefuse• Plugandplay:nosettingsneeded
UPS controller
SPD
• DINrailhousing• 1-phase(5-480W),2-phase(100W),3-phase(120-960W)
• Rated input voltage: 85-264 VAC(1-phase), 380-575 VAC (2-phase),340-575 VAC / 480-820 VDC(3-phase)
• Approvals/Marks: UL, cUL listed andTÜV/CEapproved
MAIN FEATURES• PowerFactorCorrection(PFC)• Parallelversionsavailable• Highefficiency(upto93%)
Switchingpower supply
SPUBC
• Powersupply,UPSandbatterycharger“Allinone”
• 24Vdc5Aoutput• Powerboostupto2timesratedoutput,permanent.
• Builtinbatterydiagnosys• CEandULapproved
MAIN FEATURES• Powersupplyindependentfromcharger.• Remote indication for battery operationandbatterylow
• “Startfrombattery”and“Emptybatterycharging”features
Smart UPS
GP6763xxxx
• Display the number of available carspaces
• Various types available with differentnumberofdigitsandwithalphanumericindication
• Indoorandoutdoorversionavailable• 24VDCDC-powered
MAIN FEATURES• Clear indication with long distancevisibility
• Aestheticappearence• Different operation modes selectableviaDIP-switches
Carpark displays
GP6763xxxx
• Display the number of available carspaces
• Detect and display the differencebetweenstandardanddisabledparkingspaces
• Various types available with differentnumberofdigitsandwithalphanumericindication
• Indoorandoutdoorversionavailable• 24VDCDC-poweredMAIN FEATURES• Clear indication with long distancevisibility
• Aestheticappearence• Different operation modes selectableviaDIP-switches
Carpark displays
Notes
Notes
27
HEADQUARTERSCarlo Gavazzi Automation SpAVia Milano, 13I-20020 - Lainate (MI) - ITALYTel: +39 02 931 761 [email protected]
OUR COMPETENCE CENTRES AND PRODUCTION SITESDENMARK Carlo Gavazzi Industri A/SHadsten
CHINA Carlo Gavazzi Automation (Kunshan) Co., Ltd.Kunshan
ITALY Carlo Gavazzi Controls SpABelluno
MALTA Carlo Gavazzi LtdZejtun
LITHUANIA Uab Carlo Gavazzi Industri KaunasKaunas
OUR SALES NETWORK IN EUROPEAUSTRIACarlo Gavazzi GmbHKetzergasse 374,A-1230 WienTel: +43 1 888 4112Fax: +43 1 889 10 [email protected]
BELGIUMCarlo Gavazzi NV/SAMechelsesteenweg 311,B-1800 VilvoordeTel: +32 2 257 4120Fax: +32 2 257 41 [email protected]
DENMARKCarlo Gavazzi Handel A/SOver Hadstenvej 40,DK-8370 HadstenTel: +45 89 60 6100Fax: +45 86 98 15 [email protected]
FINLANDCarlo Gavazzi OY ABPetaksentie 2-4,FI-00661 HelsinkiTel: +358 9 756 2000Fax: +358 9 756 [email protected]
ITALYCarlo Gavazzi SpAVia Milano 13,I-20020 LainateTel: +39 02 931 761Fax: +39 02 931 763 [email protected]
NETHERLANDS Carlo Gavazzi BVWijkermeerweg 23,NL-1948 NT BeverwijkTel: +31 251 22 9345Fax: +31 251 22 60 [email protected]
NORWAY Carlo Gavazzi ASMelkeveien 13,N-3919 PorsgrunnTel: +47 35 93 0800Fax: +47 35 93 08 [email protected]
PORTUGAL Carlo Gavazzi LdaRua dos Jerónimos 38-B,P-1400-212 LisboaTel: +351 21 361 7060Fax: +351 21 362 13 [email protected]
FRANCECarlo Gavazzi SarlZac de Paris Nord II, 69, rue de la Belle Etoile,F-95956 Roissy CDG CedexTel: +33 1 49 38 98 60Fax: +33 1 48 63 27 [email protected]
GERMANYCarlo Gavazzi GmbHPfnorstr. 10-14D-64293 DarmstadtTel: +49 6151 81000Fax: +49 6151 81 00 [email protected]
GREAT BRITAINCarlo Gavazzi UK Ltd4.4 Frimley Business Park,Frimley, Camberley, Surrey GU16 7SGTel: +44 1 276 854 110Fax: +44 1 276 682 [email protected]
SPAIN Carlo Gavazzi SAAvda. Iparraguirre, 80-82,E-48940 Leioa (Bizkaia)Tel: +34 94 480 4037Fax: +34 94 431 [email protected]
SWEDEN Carlo Gavazzi ABV:a Kyrkogatan 1,S-652 24 KarlstadTel: +46 54 85 1125Fax: +46 54 85 11 [email protected]
SWITZERLAND Carlo Gavazzi AGVerkauf Schweiz/Vente SuisseSumpfstrasse 3,CH-6312 SteinhausenTel: +41 41 747 4535Fax: +41 41 740 45 [email protected]
OUR SALES NETWORK IN THE AMERICASUSA Carlo Gavazzi Inc.750 Hastings Lane,Buffalo Grove, IL 60089, USATel: +1 847 465 6100Fax: +1 847 465 [email protected]
MEXICO Carlo Gavazzi Mexico S.A. de C.V.Calle La Montaña no. 28, Fracc. Los PastoresNaucalpan de Juárez, EDOMEX CP 53340Tel & Fax: [email protected]
CANADA Carlo Gavazzi Inc.2660 Meadowvale Boulevard,Mississauga, ON L5N 6M6, CanadaTel: +1 905 542 0979Fax: +1 905 542 22 [email protected]
BRAZIL Carlo Gavazzi Automação Ltda.Av. Francisco Matarazzo, 1752Conj 2108 - Barra Funda - São Paulo/SPTel: +55 11 3052 0832Fax: +55 11 3057 [email protected]
OUR SALES NETWORK IN ASIA AND PACIFICSINGAPORE Carlo Gavazzi Automation Singapore Pte. Ltd.61 Tai Seng Avenue#05-06 UE Print Media HubSingapore 534167Tel: +65 67 466 990Fax: +65 67 461 [email protected]
CHINA Carlo Gavazzi Automation(China) Co. Ltd.Unit 2308, 23/F.,News Building, Block 1,1002Middle Shennan Zhong Road,Shenzhen, ChinaTel: +86 755 83699500Fax: +86 755 [email protected]
MALAYSIA Carlo Gavazzi Automation (M) SDN. BHD.D12-06-G, Block D12,Pusat Perdagangan Dana 1,Jalan PJU 1A/46, 47301 Petaling Jaya,Selangor, Malaysia.Tel: +60 3 7842 7299Fax: +60 3 7842 [email protected]
HONG KONG Carlo Gavazzi Automation Hong Kong Ltd.Unit 3 12/F Crown Industrial Bldg.,106 How Ming St., Kwun Tong,Kowloon, Hong KongTel: +852 23041228Fax: +852 23443689
BUILD
ING
AU
TO B
RO E
NG
REV
.01
03/1
5Sp
ecifi
catio
ns a
re s
ubje
ct to
cha
nge
with
out n
otic
e. Il
lustr
atio
ns a
re fo
r exa
mpl
e on
ly.
Printedon100%recycledpaperproducedusing
postconsumerde-inkedwaste. www.gavazziautomation.com