BS 4994 V/ s
ASME Sec X
Sr No. BS-4994 ASME Sec X
1. Design begins from material
design
Takes the conventional
approach.
2. Gives guidelines regardingchemical barrier
No such guidelines are there.
3. Different sets of rules for
different manufacturing
methods that may effect
Limited to single procedure.
4. Takes into account composite
behavior of material.
Doesnt deal with composite
behavior of material.
5. Detailed design guideline for
various types of Ends (e.g.
shallow conical end, Conical
End, dished end)
More focus is on dished ends
6. Deals in unit which is
compatible with fiberglass(i.e.
N/mm per kg/m2)
Deals in S.I or British unit.
7. BS 4994 is more stringent. ASME Sec X is comparatively
less stringent