BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM - Arab · Alarm (V isual and Audible) - Standard : 30ea -...

3
Alarm (Visual and Audible) - Standard : 30ea - Option : Max. 90ea The purpose of a bridge navigational watch alarm system(BNWAS) is to monitor bridge activity and detect operator disability which could lead to marine accidents. The system monitors the awareness of the officer of the watch(OOW) and automatically alerts the captain or another qualified OOW if for any reason the OOW becomes incapable of performing the OOW's duties. Additionally, the BNWAS may provide the OOW with a means of calling for immediate assistance if required. The BNWAS should be operational whenever the ship's heading or track control system is engaged, unless inhabited by the captain. User-friendly Dimmer control Emergency call facility Timer display Motion sensor with infrared and microwave detection Auto-run input(Auto pilot) Main supply DC24V or AC220V BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM HBN- 117 System Feature SYSTEM ALARM STAGE BRIDGE VISUAL BRIDGE AUDIO OFFICER CALL CREW CALL T I M E R OFFICER RUN OFF AUTO SECOND MINUTE DC POWER AC POWER FAIL ALARM RST HBN - 117 Bridge Navigational Watch Alarm System CREW DIMMER / SET MIN / SEC RST RST RESET (mode) EM'CY CALL EM'CY CALL EM'CY CALL

Transcript of BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM - Arab · Alarm (V isual and Audible) - Standard : 30ea -...

Page 1: BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM - Arab · Alarm (V isual and Audible) - Standard : 30ea - Option : Max. 90ea The purpose of a bridge navigational watch alarm system(BNW AS)

Alarm (Visual and Audible) - Standard : 30ea - Option : Max. 90ea

The purpose of a bridge navigational watch alarm system(BNWAS) is to monitor bridgeactivity and detect operator disability which could lead to marine accidents. The system monitors the awareness of the officer of the watch(OOW) and automaticallyalerts the captain or another qualified OOW if for any reason the OOW becomes incapableof performing the OOW's duties. Additionally, the BNWAS may provide the OOW with a means of calling for immediate assistance if required.The BNWAS should be operational whenever the ship's heading or track control systemis engaged, unless inhabited by the captain.

User-friendlyDimmer controlEmergency call facilityTimer displayMotion sensor with infrared and microwave detection Auto-run input(Auto pilot)Main supply DC24V or AC220V

BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM

HBN - 117

System Feature

SYSTEM

ALARM STAGE

BRIDGE VISUAL

BRIDGE AUDIO

OFFICER CALL

CREW CALL

T I M E R

OFFICER

RUNOFF AUTO

SECOND

MINUTE

DC POWER

AC POWER

FAIL ALARM

RST

HBN - 117 Bridge Navigational Watch Alarm System

CREW

DIMMER / SET

MIN/

SECRST RST

RESET(mode)

EM'CY CALLEM'CY CALLEM'CY CALL

Page 2: BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM - Arab · Alarm (V isual and Audible) - Standard : 30ea - Option : Max. 90ea The purpose of a bridge navigational watch alarm system(BNW AS)

BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM

Captain

HBN - 117 SYSTEM DIAGRAM

Auto pilotAC

DCAMS

Motion sensorMotion sensor(BNP-720)(BNP-710)

C / Officer

2nd / Officer

Officer Deck

W/H

RESET

DIMMER

BNP-710 BNWAS

BNP-720 BNWAS

DIMMER

RESET

12min(3~12)

15sec

15sec

90sec(90~180)

3rd STAGE REMOTE AUDIBLE ALARM (CREW CALL)2nd STAGE REMOTE AUDIBLE ALARM (OFFICER CALL)1st STAGE REMOTE AUDIBLE ALARM (BRIDGE)

VISUAL INDICATOR (RESET SWITCH FLICKER)

TIME CHART

Crew Deck 1

(BNP-740) (BNP-741)

BNWAS BNWASBNWAS BNWAS

3rd / Officer

BNWAS BNWASBNWAS

Crew Deck 2

J.B

J.B

POWER SUPPLY HPS - 100B ( 24V,3A )

AC

DC

-Option-

J.B

BNWAS

SYSTEM

ALARM STAGE

BRIDGE VISUAL

BRIDGE AUDIO

OFFICER CALL

CREW CALL

T I M E R

OFFICER

RUNOFF AUTO

SECOND

MINUTE

DC POWER

AC POWER

FAIL ALARM

RST

HBN - 117 Bridge Navigational Watch Alarm System

CREW

DIMMER / SET

MIN/

SECRST RST

RESET(mode)

EM'CY CALLEM'CY CALLEM'CY CALL

Page 3: BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM - Arab · Alarm (V isual and Audible) - Standard : 30ea - Option : Max. 90ea The purpose of a bridge navigational watch alarm system(BNW AS)

BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM

HBN - 117 Detail of Devices

Model MAIN (HBN - 117)

Power Source

Dimension / Weight

ConsumptionW/H In / Output

MainEm'cy

AC100 ~ 220VDC24V

Max. 1.2AMax. 4 port (Reset, Visual, Audible Alarm)

Officer Output Max. 2 portCrew Output Max. 2 port

Motion Sensor Max. 2 portAuto Run Max. 4 port (Normal Open or Normal Close, $--HTD)

W270 X H188 X D110, 3kgNMEA Output $BNALR (IEC-61162-1, RS-422 / 4,800bps or 38,400bps)Fault Output Max. 2 port (Normal Open or Normal Close)

Desk type Wall type

W210 X H145 X D105, 2kg

DIMENSIONSOUND LEVEL

DC24V, Max 20mAPOWER SOURCE DC24V, Max 70mA

85dB/m,var.volume & tone

120W X 80H X 70D0.5kg 0.1kg

80W X 80H X 57D

85dB/m

DC24V, Max 30mA

BNP - 710F

Reset,Visual Alarm

BNP - 720F BNP - 730FMODEL

0.5kgWEIGHT80W X 120H X 70D

ALARM UNITRESET

DIMMER

BNP-710 BNWAS

BNP - 750A/R (IP65)

0.2kg / 0.15kg80W X 80H X 73D / 25

85dB/m

DC24V, Max 30mA / Max 15mA

BNP-720 BNWAS

DIMMER

RESET

BNWAS BNWAS

MODEL

DC24V, Max 30mA

80W X 80H X 58.7D0.15kg0.8kg

120W X 80H X 80D

DC24V, Max 70mAPOWER SOURCE DC24V, Max 20mA

SOUND LEVELDIMENSION 80W X 120H X 80D

WEIGHT 0.8kg

ALARM UNIT

BNP - 710 BNP - 720 BNP - 730

85dB/m, var. vol & tone 85 dB/m

BNWAS

DISCRIPTION Reset,Visual,Audible Alarm Audible Alarm Reset,Visual,Audible Alarm

Reset,Visual Alarm Reset,Visual,Audible Alarm Audible Alarm DISCRIPTION

SYSTEM

ALARM STAGE

BRIDGE VISUAL

BRIDGE AUDIO

OFFICER CALL

CREW CALL

T I M E R

OFFICER

RUNOFF AUTO

SECOND

MINUTE

DC POWER

AC POWER

FAIL ALARM

RST

HBN - 117 Bridge Navigational Watch Alarm System

CREW

DIMMER / SET

MIN/

SECRST RST

RESET(mode)

EM'CY CALLEM'CY CALLEM'CY CALL