Brays Bayou
description
Transcript of Brays Bayou
![Page 1: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/1.jpg)
Brays Bayou
Concrete Channel
CH 7 - Open Channel Flow
1. Uniform & Steady
2. Non-uniform and Steady
3. Non-Uniform and Unsteady
![Page 2: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/2.jpg)
Open Channel Flow
1. Uniform & Steady - Manning’s Eqn in prismatic channel - Q, v, y, A, P, B, S and roughness are all constant
2. Critical flow - Specific Energy Eqn (Froude No.)
3. Non-uniform flow - gradually varied flow (steady flow) - determination of floodplains
4. Unsteady and Non-uniform flow - flood waves
![Page 3: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/3.jpg)
Uniform Open Channel Flow
Manning’s Eqn for velocity or flow
€
v =
1
n
R
2 / 3
S S.I. units
v =
1 . 49
n
R
2 / 3
S English units
where n = Manning’s roughness
coefficient R = hydraulic radius = A/PS = channel slope
Q = flow rate (cfs) = v A
![Page 4: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/4.jpg)
Normal depth is function of flow rate, and
geometry and slope. One usually solves for normal
depth or width given flow rate and slope information
B
b
![Page 5: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/5.jpg)
Normal depth implies that flow rate, velocity, depth,
bottom slope, area, top width, and roughness remain
constant within a prismatic channel as shown below
A
Q = ConstV = Cy = CS0 = CA = CB = Cn = C
UNIFORM FLOW
y
So
B
V
![Page 6: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/6.jpg)
Common Geometric Properties Cot = z/1
z
1
1 + Z2
![Page 7: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/7.jpg)
Optimal Channels - Max R and Min P
![Page 8: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/8.jpg)
Uniform FlowEnergy slope = Bed slope or dH/dx = dz/dx
Water surface slope = Bed slope = dy/dz = dz/dx Velocity and depth remain constant with x
H = z + y + v2/2g = Total Energy
E = y + v2/2g = Specific Energy
often near 1.0 for most channels
H
= vi2 Qi
V2 QT
Energy Coeff.
![Page 9: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/9.jpg)
My son Eric
Critical Depth and Flow
![Page 10: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/10.jpg)
Critical depth is used to characterize channel flows -- based on addressing specific energy E = y + v2/2g :
E = y + Q2/2gA2 where Q/A = q/y and q = Q/b
Take dE/dy = (1 – q2/gy3) and set = 0. q = const
E = y + q2/2gy2
y
E
Min E Condition, q = C
![Page 11: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/11.jpg)
Solving dE/dy = (1 – q2/gy3) and set = 0.
For a rectangular channel bottom width b,
1. Emin = 3/2Yc for critical depth y = yc
2. yc/2 = Vc2/2g
3. yc = (Q2/gb2)1/3
Froude No. = v/(gy)1/2
We use the Froude No. to characterize critical flows
![Page 12: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/12.jpg)
Y vs E E = y + q2/2gy2
q = const
![Page 13: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/13.jpg)
![Page 14: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/14.jpg)
In general for any channel shape, B = top width
(Q2/g) = (A3/B) at y = yc
Finally Fr = v/(gy)1/2 = Froude No.
Fr = 1 for critical flowFr < 1 for subcritical flowFr > 1 for supercritical flow
Critical Flow in Open Channels
![Page 15: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/15.jpg)
![Page 16: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/16.jpg)
Non-Uniform Open Channel Flow
With natural or man-made channels, the shape, size, and slope may vary along the stream length, x. In addition, velocity and flow rate may also vary with x. Non-uniform flow can be best approximated using a numerical method called the Standard Step Method.
![Page 17: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/17.jpg)
Non-Uniform Computations
Typically start at downstream end with known water level - yo.
Proceed upstream with calculations using new water levels as they are computed.
The limits of calculation range between normal and critical depths. In the case of mild slopes, calculations start downstream.In the case of steep slopes, calculations start upstream.
Q
Calc.
Mild Slope
![Page 18: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/18.jpg)
Non-Uniform Open Channel Flow
Let’s evaluate H, total energy, as a function of x.
H = z + y + v
2
/ 2 g
( )
dH
dx
=
dz
dx
+
dy
dx
+
2 g
dv
2
dx
⎛
⎝
⎜
⎞
⎠
⎟
Where H = total energy headz = elevation head,
v2/2g = velocity head
Take derivative,
![Page 19: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/19.jpg)
Replace terms for various values of S and So. Let v = q/y = flow/unit width - solve for dy/dx, the slope of the water surface
– S = − S
o
+
dy
dx
1 −
q
2
gy
3
⎡
⎣
⎢
⎤
⎦
⎥
since v = q / y
1
2 g
d
dx
v
2
[ ]=
1
2 g
d
dx
q
2
y
2
⎡
⎣
⎢
⎤
⎦
⎥
= −
q
2
g
1
y
3
⎡
⎣
⎢
⎤
⎦
⎥
dy
dx
![Page 20: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/20.jpg)
Given the Froude number, we can simplify and solve for dy/dx as a fcn of measurable parameters
Fr
2
= v
2
/ gy
( )
dy
dx
=
S
o
− S
1 − v
2
/ gy
=
S
o
− S
1 − Fr
2
where S = total energy slopeSo = bed slope, dy/dx = water surface slope
*Note that the eqn blows up when Fr = 1 and goes to zero if So = S, the case of uniform OCF.
![Page 21: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/21.jpg)
![Page 22: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/22.jpg)
Mild Slopes where - Yn > Yc
Uniform Depth
Yn > Yc
![Page 23: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/23.jpg)
Now apply Energy Eqn. for a reach of length L
y
1
+
v
1
2
2 g
⎡
⎣
⎢
⎤
⎦
⎥
= y
2
+
v
2
2
2 g
⎡
⎣
⎢
⎤
⎦
⎥
+ S − S
o
( )L
L =
y
1
+
v
1
2
2 g
⎡
⎣
⎢
⎤
⎦
⎥
− y
2
+
v
2
2
2 g
⎡
⎣
⎢
⎤
⎦
⎥
S − S
0
This Eqn is the basis for the Standard Step Method Solve for L = x to compute water surface profiles as function of y1 and y2, v1 and v2, and S and S0
![Page 24: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/24.jpg)
Backwater Profiles - Mild Slope Cases
x
![Page 25: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/25.jpg)
Backwater Profiles - Compute Numerically
Computey3 y2 y1
![Page 26: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/26.jpg)
Routine Backwater Calculations1. Select Y1 (starting depth)
2. Calculate A1 (cross sectional area)
3. Calculate P1 (wetted perimeter)
4. Calculate R1 = A1/P1
5. Calculate V1 = Q1/A1
6. Select Y2 (ending depth)
7. Calculate A2
8. Calculate P2
9. Calculate R2 = A2/P2
10. Calculate V2 = Q2/A2
![Page 27: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/27.jpg)
Backwater Calculations (cont’d)
1. Prepare a table of values
2. Calculate Vm = (V1 + V2) / 2
3. Calculate Rm = (R1 + R2) / 2
4. Calculate Manning’s
5. Calculate L = ∆X from first equation
6. X = ∑∆Xi for each stream reach (SEE SPREADSHEETS)
€
S =nVm
1.49Rm2
3
⎛
⎝ ⎜ ⎜
⎞
⎠ ⎟ ⎟
2
€
L =
y1 + v12
2g
⎛
⎝ ⎜
⎞
⎠ ⎟−y2 + v2
2
2g
⎛
⎝ ⎜
⎞
⎠ ⎟
S − S0
Energy Slope Approx.
![Page 28: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/28.jpg)
100 Year Floodplain
Main Stream
Tributary
Cross Sections
Cross Sections
A
B
C
D
QA
QD
QC
QB
Bridge Section
Bridge
Floodplain
![Page 29: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/29.jpg)
The Floodplain
Top Width
![Page 30: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/30.jpg)
Floodplain Determination
![Page 31: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/31.jpg)
The Woodlands planners wanted to design the community to withstand a 100-year storm.
In doing this, they would attempt to minimize any changes to the existing, undeveloped floodplain as development proceeded through time.
The Woodlands
![Page 32: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/32.jpg)
HEC RAS or (HEC-2)is a computer model designed fornatural cross sections in natural rivers. It solves the governing equations for the standard step method, generally in a downstream to upstream direction. It can Also handle the presence of bridges, culverts, and variable roughness, flow rate, depth, and velocity.
HEC RAS (River Analysis System, 1995)
![Page 33: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/33.jpg)
HEC - 2
Orientation - looking downstream
![Page 34: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/34.jpg)
![Page 35: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/35.jpg)
![Page 36: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/36.jpg)
![Page 37: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/37.jpg)
![Page 38: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/38.jpg)
Multiple Cross Sections
River
![Page 39: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/39.jpg)
HEC RAS (River Analysis System, 1995)
![Page 40: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/40.jpg)
HEC RAS Bridge CS
![Page 41: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/41.jpg)
HEC RAS Input Window
![Page 42: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/42.jpg)
HEC RAS Profile Plots
![Page 43: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/43.jpg)
3-D Floodplain
![Page 44: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/44.jpg)
HEC RAS Cross Section Output Table
![Page 45: Brays Bayou](https://reader036.fdocuments.us/reader036/viewer/2022081419/568145b8550346895db2c032/html5/thumbnails/45.jpg)
Brays Bayou-Typical Urban System• Bridges cause unique problems in hydraulics
Piers, low chords, and top of road is considered
Expansion/contraction can cause hydraulic losses
Several cross sections are needed for a bridge
288 Bridge causes a 2 ft
Backup at TMC and is being replaced by TXDOT
288 Crossing