Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate and Sensitive with Auto Ranging Low end +/ - .0001% = one unit (on 10,000 unit full range) High end +/- 1 % full scale Reliability No filament, flame or pellistor to fail No saturation No in field calibration (set and stable for 18 months) No drift from filament degradation No drift from carbonization CO2 - included O2 - included H2S - included DATA Triple redundant data records Real time (6 second new data capture cycle) data viewing at rig site or anywhere world wide via web site WITS compatible (can output or collect and display incoming drilling data) AUTOMATION Remote systems diagnostic capabilities Multiple function alarm system Automatically generated real time mudlog (just add lithology) Automatic sample flow monitor and adjustment COMMUNICATION Hardwire and wireless communication capabilities Built in GPRS data modem eliminates satellite dish and rental costs Alarm notification via cell phone text message world wide POWER Low operating current design (DC low voltage extends life and eliminates shock danger) Functional from 12v car electrical system Up to 120 min on board backup power supply (with monitor) MONITORING Remote diagnostics on sample flow, sample line vacuum pressure, total hydrocarbons and other functions Multiple function automatic alarms based on custom high low parameters Automatic alarm notification via cell text message 24/7 remote manned alarm monitoring service packages http://www.bloodhoundrentals.com

Transcript of Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas...

Page 1: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System• 0-100%  auto ranging • Total gas with Chromatograph model- C1-C4 iso and C4

normal • Accurate and Sensitive with Auto Ranging • Low end +/ - .0001% =  one unit (on 10,000 unit full range) • High end +/- 1 % full scale • Reliability

– No filament, flame or pellistor to fail – No saturation – No in field calibration (set and stable for 18 months) – No drift from filament degradation – No drift from carbonization

• CO2 - included• O2   - included • H2S - included

DATA • Triple redundant data records • Real time (6 second new data capture cycle) data viewing at

rig site or anywhere world wide via web site • WITS compatible (can output or collect and display incoming

drilling data)

 AUTOMATION • Remote systems diagnostic capabilities • Multiple function alarm system • Automatically generated real time mudlog (just add lithology) • Automatic sample flow monitor and adjustment

 COMMUNICATION• Hardwire and wireless communication capabilities • Built in GPRS data modem eliminates satellite dish and rental costs • Alarm notification via cell phone text message world wide

 POWER

• Low operating current design (DC low voltage extends life and eliminates shock danger)

• Functional from 12v car electrical system • Up to 120 min on board backup power supply (with monitor)

MONITORING• Remote diagnostics on sample flow, sample line vacuum pressure,

total hydrocarbons and other functions • Multiple function automatic alarms based on custom high low

parameters • Automatic alarm notification via cell text message • 24/7 remote manned alarm monitoring service packages

http://www.bloodhoundrentals.com

Page 2: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Bloodhound™ Logging System Side View Sample Gas inlet

Port has regulated flow and vacuum

pressure

Exhaust port. ½” size keeps the line

from freezing in cold weather

Geolograph switch input

GPRS Radio antenna

Ethernet RJ-45 to Internet

Audio Alarm

Positive Pressure vent air

supply. Inside case under

positive pressure with filtered air.

Analog Out Relay contacts

for Depth & Alarms

DC power in/out Runs from DC car adaptor

or powers DC devices e.g. iBall Cavitator

Universal AC power From 90-250VAC

power and 45-65 Hz

WITSPason

compatible RS422

interface

WITSNull Modem Connection(9-pin FtoF)

RS232 Straight-thru Personal Computer

or External Data logger

USB-B Serial (COM)

PC connection (PC Driver Req’d)

Page 3: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Gas Charting Functions

•Calculates Lag•Set PC Alarms•Edit Depth•Zoom on Chromats•Data File Export

Communication Network

http://www.bloodhoundrentals.com

Internet

64.19.xx.xx:xxxx

Bloodhound™Data Archive

Web Remote Gas ChartWeb Browser

Well Status via Mobile Device Accesse.g. Voice Response – Text - Email

GPRS Cell RadioAT&T Data Service

Field Data NetworkEthernet connection(e.g. Sat. Internet)

Bloodhound™ Logging System• Total Gas• Gas Chromatography• CO2• O2• H2S• Local Instrument Alarms

Serial ConnectionInstrument to PC

At Well Site

WITS

WITs to EDR

Gas Chart - Local

Well Site PC

Gas Chart - Remote

Remote PC

Gas Chart - Remote

Remote PC

Page 4: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Data Logger SoftwareUsed both for Local & Remote Logging

• Application Logging software used Locally or Remotely

• Real-Time Data– Table (6 sec update)– Flexible Charting capability

• Configuration– Lag– Depth editing– Scale adjustments– Export LAS and XLS data

file for importing to any Mudlogging software

http://www.bloodhoundrentals.com

Page 5: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Web Remote Data Logger

• Accessible from any Internet connected browser

• Real-Time Data– Table

• 10 sec update

– Chart Image• 1 min update

• Comment Editing Capable

http://www.bloodhoundrentals.com

Page 6: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Mobile Device Access

• Mobile Phones based on Windows Mobile

http://www.bloodhoundrentals.com

• IPhone

Page 7: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Real-Time Data Viewer

Sample Line Vacuum

Pressure Great for

troubleshooting leaks, blockages

etc.

Flow Rate Automatically

controlled

Variable Speed Sample Pump controls Flow

Rate to Set Point

RSSIReceived

SignalStrength Indicator

Monitors Cell network signal

http://www.bloodhoundrentals.com

Page 8: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Real-Time Data Viewerwith WITS Stream Viewer

Page 9: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Multiple Well Real-Time Data Viewer

Page 10: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Website Multiple Instrument Viewerhttp://www.iballmultiview.com

• Accessible from any Internet connected browser

• Multiple Well Snapshot View– Real-Time Data

– Table• 10 sec update

Page 11: Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

24/7 Call Center Support(303-459-4660)

• Technical Support– Tier 1 call center agents available 24 hours a day, 7 days a week

• Interactive Voice Response (IVR) w/Text & Email– Voice Response - Available 24/7 for retrieving a voice response

that recites individual Bloodhound Hole Depth, Bit Depth and Total Gas

– Text Message - Available 24/7 for retrieving Hole Depth, Bit Depth, Total Gas, Sample line flow rate, Vacuum pressure and ROP in min/ft and ft/hr

– Email – Available 24/7 by request with all Bloodhound diagnostic information