BEYOND - GenMark...• Bi-directional LIS, automating and accelerating order entry and results...
Transcript of BEYOND - GenMark...• Bi-directional LIS, automating and accelerating order entry and results...
BEYONDEXPECTATIONS
ePlex®: The True Sample-to-Answer SolutionTM
ePlex is the only sample-to-answer
system that streamlines the diagnostic
workflow from physician order entry
to the final test report with accurate,
actionable results. ePlex offers
unique solutions to address the most
significant challenges facing clinical
laboratories, while supporting hospital
systems to deliver patient-centered,
value-based care.
True Sample-to-Answer Workflow
ePlex delivers lean, true sample-to-answer workflow to support 24/7 testing with consistent
order-to-report service levels.
• Shortest hands-on time among multiplex sample-to-answer systems1
• Bi-directional LIS, automating and accelerating order entry and results reporting
• Random, continuous access with a modular, scalable design to provide capacity during
peak season demand
Only ePlex provides bi-directional LIS capability with sample traceability throughout the testing process to streamline and integrate workflow. The system consistently delivers fast, accurate, and clinically actionable results to enhance patient care.
SUMMARYAdenovirus, Parainfluenza Virus 2 and Respiratory Syncytial Virus A Detected.
Operator Signature Approver SignatureDate Date
Viral Targets ResultAdenovirus DetectedCoronavirus 229E Not DetectedCoronavirus HKU1 Not DetectedCoronavirus NL63 Not DetectedCoronavirus OC43 Not DetectedHuman Metapneumovirus Not DetectedHuman Rhinovirus/Enterovirus Not DetectedInfluenza A Not Detected Influenza A H1 Not Detected Influenza A 2009 H1N1 Not Detected Influenza A H3 Not DetectedInfluenza B Not Detected
Viral Targets ResultParainfluenza Virus 1 Not DetectedParainfluenza Virus 2 DetectedParainfluenza Virus 3 Not DetectedParainfluenza Virus 4 Not DetectedRespiratory Syncytial Virus A DetectedRespiratory Syncytial Virus B Not Detected
Bacterial TargetsBordetella pertussis Not DetectedChlamydophila pneumoniae Not DetectedMycoplasma pneumoniae Not Detected
Internal Control PASS
RESULTS
COMMENTS
FLAGS
1 / 110/25/2016 3:16 PM
For In Vitro Diagnostic Use.
Regional Medical Center | 5964 LaPlace Ct, Carlsbad, CA
RP Detection ReportAccession ID:
Protocol:
Instrument Serial Number:Operator:Software Version:
Date/Time Completed:Bay Location:
Cartridge Expiration Date:Cartridge Lot Number:Cartridge ID:
555666777888
RP 1.3.15.21.0.6.1Internal1541100045
10/25/2016 3:15 PMA112345614062516204810/18/2018
Patient ID: Unknown
Test Ordering / Sample Collection
Central Receiving & Sort
Transport to Lab Accession
SampleReport Results
Process Sample
Physician Test Order
Physician Test Results
Test ResultsTest Order
Patient Safety
ePlex reduces the potential for patient identification and reporting errors, so labs and physicians
can report results with confidence.
• Patented positive patient ID reduces the potential for patient sample mix-up
• True bi-directional LIS can help eliminate transcription errors
Patient-Centered Care
ePlex provides rapid, comprehensive test results for critical patients to help institutions lower
overall cost of care by reducing length of stay and inappropriate use of certain therapies, while
also improving key quality metrics including infection control and antimicrobial stewardship.
Compliance & Data Management
Maximize lab efficiency by reducing the administrative overhead associated with monitoring
lab performance, tracking quality control testing, and managing data required for regulatory
compliance.
• Automated QC tracking and onboard QC test records help ensure the lab runs controls
when required
• Integrated data analytics and on-demand epidemiology reports
Your Long-Term Partner
GenMark is committed to remaining an industry leader in customer satisfaction. Year after year,
respondents rank GenMark as delivering best-in-class service and support.2
• Secure, remote access capability for on-demand ePlex troubleshooting and diagnostics
• On-site training, preventative maintenance, repairs, and LIS integration assistance
REFERENCES: 1. Based on independently-validated workflow study. Details furnished upon request. 2. GenMark Annual Customer Satisfaction survey, by Survey Monkey 2015. Details furnished upon request.
*For In Vitro Diagnostic Use. †Product in Development. Not available for sale in the US. Panel targets and specifications subject to change.
© 2017 GenMark Diagnostics, Inc. GenMark, GenMark Dx, ePlex, The True Sample-to-Answer Solution, and Designed for the Patient, Optimized for the Lab are trademarks or registered trademarks of GenMark Diagnostics, Inc. GNMK-IMC-2052-A
GenMark Diagnostics, Inc.5964 La Place CourtCarlsbad, CA 92008USA
GenMark Diagnostics Europe GmbHGeneral-Guisan-Strasse 66303 ZugSwitzerland [email protected]
Respiratory Pathogen (RP) Panel* The most common clinically-relevant viral and bacterial targets
associated with upper respiratory infections
Blood Culture Identification Panels†
(BCID-GP, BCID-GN, and BCID-FP)†
Designed to provide the most comprehensive coverage of
sepsis-causing organisms to improve clinical outcomes and
antibiotic stewardship
Gastrointestinal Pathogen (GI) Panel†
Bacterial, viral, and parasitic pathogens associated with
gastrointestinal infections
Comprehensive ePlex® Menu
For more information on ePlex® please visit www.genmarkdx.com