Bentley’s Substation Design Solution
Bentley’s Substation Design Solution
A comprehensive solution to design and maintain substations ...
− Relay design − Structural and foundation
design− Maps and site plans
Key Capabilities
• Automated Drawings− 3-D Model− Construction Documents− One Line− Three Line− Protection & Controls
• Visualization− Renderings− Animations− Check for Interferences− Schedule Simulation
• Bill of Materials− Kept in sync with the drawings
• Automated drawings• Visualization• Bill of materials generation• Automated standards
based design• Management of existing
substation information− CAD− Raster− Hybrid− Database
Key Capabilities
Managed work groups...
− File and equipment Information− Workflow− Powerful search capabilities− Browser access− Comprehensive reporting
Interoperability with existing systems...
− Materials Management− Work Management− Spatial databases− GIS (ESRI)− SAP
A Complete Work Environment
Supporting both construction and maintenance...
− 3D equipment modeling− Electrical clearance checks− Interference detection − Support assemblies− Standard work units (MU/CU)− Automated drawing extraction− Visualization and walkthrough
General Arrangement
Electrical documentation...
− Schematic design− Intelligent schematic
diagrams− AC and DC elementary
diagrams− Misc. schematic diagrams− Vendor schematics in vector,
raster or hybrid raster/vector
EHA
RR SWPROT. DGN
DC SCHEMATICCIRCUIT SWITCHER #CS & MOS #MO
TRANSFORMER PROTECTION SCHEME
AT CONTROL HOUSE
AT CIRCUIT SWITCHER
AT CONTROL HOUSE
AT MOS
14
86TD
3
16
4
A11
B11TB12-2
14
86TBU
3
16
4
1
2
R
86TD/TS1 BB
15
86TBU
17
CSTP CST
1
2
G
TB10-2 TB10-1
CSC
TB10-4 TB10-3
CSCP
15
86TD
17
B1
A1
CSC
TB10-5
CIRCUIT SWITCHER #CSCONTROL SCHEMATIC
S&C SERIES 2000
RED
TA7CS015
GRN
TA8CS015
TA1CS015
TA2CS015
ORGCS015 CS015
ORG/BLK GRN/BLK
3012 1 2
FRN 69-1
1
2
PB/C
TA3
1
LS0-22 3
1
6
2
CC
7 8ab2
24
23b
28
27b
R
RS
-1
3
G
RS
-1
1
13a
12
16a
18b
TA10
17
1
TC
2
3034
FRN
2 1
P(+)
TB22
CSP(+)
BLKCS013
4 3TB23
N(-)CSN(-)
WHTCS013
L1MC
T1
T2MC
L2
C4MC
C5A2
A1
M
RE
S
1
2
T3MC
L3
54
LSO-1
11
ab1
54
1
2
CTR
32
LSC-1
C2MC
C3
23
LSC-2
1
C7
C8
SU MC
1
2
TA4 TA5
TD51
TD52
34
33b
125V
DC
1
2
R
1
2
G
21
23
86TBU
21
23
86TD
A1
B1
CSC
SUPVC
TB11-4
M0021
MOC
15
TB11-5
M0021
22
TB11-6
M0021
24
TB11-3
M0021
MOC
21
TB11-1
M0 0 2 1
MOP
13
RED
22
28
86TBU
TB12-5
SUPVT
22
28
A11
B11
CST
86TDMOT
MOT
C5
6
86TBUTS2 C
5
6
86TDTS1
CS015
43
44
89b
TB10-11
TD57
CKT SWR#CS( )
TD58
CS015
TB10-12
TB11-2
MOT
M0021
14
GRNM0021BLU
43
TB10-7 TE72 TE7389b
67 68
CKT SWR#CS( )
TB10-8
TB11-7
CS015BLU
MOP(+)
BLKM0019
MOTOR OPERATED SWITCH #MOCONTROL SCHEMATIC
SOUTHERN STATES TYPE VM-1
19
+
MSOL
30A
STOP
OPEN
13
14CC
13CC14
OLS
OC
CLS
CC
SSOPEN
SSCL OSE
CLOSE
M0019
18
-
MS
30AMON(-)
WHT
12
5V
DC
2
1
2
1OC CC
BC
4
3CC
4
3OC
6
5CC
6
5OC
ARM
23 25
5
6
7
8
89b
89a
TB6-5
TB6-6
10
989 b
26
27
TO RTU
M OS OP EN
S CADA IND.12
89 a
28
29
( )MOS#MO( )MOS
#MO
TO RTU
M OS CLOS ED
S CADA IND.
W-2POSITIONS
TRIP NEUT. CLOSEPULL
NEUT.
CS
X
X X
X
X
X X
X
X
X X X
X
X X X
A11-B11
A12-B12
A1-B1
A5-B5
A6-B6
A7-B7
C12-C1
D12-D1
C6-C7
D6-D7
SCHEMATIC WIRING
MOS #MOCONTROL HOUSE
G R
MOTOR OPERATED SWITCH CONTROL
PULL FOR SUPERVISORY
TRIP CLOSE
CSELECTROSWITCH
#508A236G04PISTOL GRIP HANDLE 310C624H02
NAMEPLATE 502A054H02
G R
PULL FOR SUPERVISORY
TRIP CLOSE
CSELECTROSWITCH
#508A236G04PISTOL GRIP HANDLE 310C624H02
NAMEPLATE 502A054H02
W-2POSITIONS
TRIP NEUT. CLOSEPULL
NEUT.
CS
X
X X
X
X
X X
X
X
X X X
X
X X X
A11-B11
A12-B12
A1-B1
A5-B5
A6-B6
A7-B7
C12-C1
D12-D1
C6-C7
D6-D7
48
89 b
37
89 a
TO RTU
CKT. S W. CLOS ED
S CADA IND.
TO RTU
CKT. S W. OP EN
S CADA IND.TD61
CKT SWR#CS( )
CKT SWR#CS( )
47
TD60
TD54
36
TD53
CIRCUIT SWITCHER CONTROL
CICUIT SWITCHER#CS
CONTROL HOUSE
PB/T
1 2
2 4
11
CS015
1
M 0 2 2M 0 0 2 2
MOC6
C6
C7
CSPULL/NUET.
CS /M 0 3TO RTU
S UP V.
DIS ABLE
IND.
AT CONTROL HOUSE
AT MOS
ORG/BLK ORG GRN/BLK RED/BLK
TERMINAL @ TRANSFORMER PANEL
TERMINAL @ CIRCUIT SW ITCHER
TERMINAL @ MOTOR OPERATED SW ITCH
MOP
WHT/BLK
MOP
MOG(LT) MOR(LT)MOT
TB12-7 TB12-8
TB12-11
CS/PN
D6
D7
D1
D12
CS/PN
TB12-10
TB12-6
BLU/BLK
BLK/WHT
MOT
MOT
TERMINAL @ TRANSFORMER PANEL
TERMINAL @ CIRCUIT SW ITCHER
TERMINAL @ MOTOR OPERATED SW ITCH
TB6-7
TB6-8
CSC6
C6
C7
CSPULL/NUET.
CS /M 0 3TO RTU
S UP V.
DIS ABLE
IND.
CSC7
MOC7
AT CONTROL HOUSE
AT CIRCUIT SWITCHER
CS 0 1 6
CS 0 1 6
RED/BLK
CSG(LT)
TB12-4 TB10-6
CSC
SUPVC
CS/PND6
D7
TB12-3
CST
86TBUTS2
SUPVT
CS/PND1
D12
TB12-1
#18SH
#18SH
#18SH
#18SH
#18SH
#18SH
#18SH
#18SH#18SH
#18SH #18SH
#18SH
NONE
E5. 0
EHA
RR SWPROT. DGN
DC SCHEMATICCIRCUIT SWITCHER #CS & MOS #MO
TRANSFORMER PROTECTION SCHEME
NONE
E5. 0
ci
etawets
W
tse
i
cinuMd
ae
W
YT
IC
8581. TSE
DR
OF
EHTAEW
P ro fessio n al E n g in eerin g S erv ices-E lect ric P o wer & Co mmu n icat io n s
Alexander Utility Engineering, Inc.FI LE NAME:
CHECKED BY:
RAILROAD SUBSTATION
DRAWN BY:
DATE:
SCALE:
SHEET
TFM 11- 1- 00
A T E O F T E X
L I C E N S E D
P
S S I O N A L E N G
R
3 1 3 4 0
LEO NARD H. HI L L
Th e s e a l ap pe ar in g on t h is do c u m en t wa s a ut ho r iz ed by
Le on ar d H. Hill, P. E. 31 34 0, on , 2 0 .NO V 1 00
THIS DRAWING I S RELEASED FOR CONSTRUCTI ON
NOTE: THIS DRAWING IS VALID ONLY FOR THE SPECIFIC EQUIPMENT MANUFACTURER AND TYPE SHOWN.
Relay Design
Structural and foundation design...
− Design of structures
− Foundation design
− Integration with Bentley STAAD
− Optional interface to structural analysis (FEA) programs:
» GT STRUDL» MIDAS» S-FRAME
Structural Design
Control house design...
− Layout of control house including electrical and mechanical equipment
− Use of architectural components & standard designs in Catalog
− Architectural design to optimally address site requirements
Functional Design
Civil and site engineering...
− Survey/ETI data interface− Build digital terrain model− Site design − Earthworks calculations− Elevations of finished sub
grade.− Access road, culverts, and
drainage surfacing design− Clearance for removal and
installation of equipment.
Site Design
Interoperability with other systems...
− ProjectWise with Geospatial Management Extension (ProjectWise)
− Consultancy for integration to Materials Management, Work Management and other enterprise systems
Enterprise Integration
A Complete PortfolioMicroStation based design...
− Bentley Architecture− Bentley I/RAS B− Bentley Structural− Bentley Navigator− Bentley Schematics− Bentley PowerCivil− Bentley Substation – 3D Layout− Bentley Substation - Electric− Bentley Plot Organizer− PDF Composer− ProjectWise Named User
Workflow based data management ...
− ProjectWise− ProjectWise Geospatial Management− ProjectWise Web Server− ProjectWise Plot Server− ProjectWise Publishing Server
Bentley Substation Design
Improve revenue, avoid costs, and improve service...
− Bring new stations on-line sooner− Operate existing stations more
efficiently− Reduce errors in design and
construction− Integrate with other systems for
improved operational efficiency
Thank You