ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues...
Transcript of ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues...
![Page 1: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/1.jpg)
ARCHITECTURE IN STEEL
![Page 2: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/2.jpg)
www.dynamicwindows.com
Whether it’s the conversion of an industrial warehouse, a landmark building in a historic district or a tightly controlled University specification the combination of glazing flexibility, energy performance and narrow thermally broken profiles is a unique combination.
The profile face features widths from 1” to 1 9/16”. The new cold rolled steel in combination with the glassfibre-reinforced high performance composite thermal-break results in minimal heat loss with superior strength and stability when compared to traditional hot rolled profiles. The 2 3/8ths inch deep frame accommodates
a wide range of glass specification flexibility without the need of special setup costs or profiles. Whether it is triple glazed, double glazed or combinations of thicker laminated glass & high performance glasses, the flexibility is unique in the steel window industry.
Steel-Arte is also a superior solution for luxury residential applications. The strength of the Steel-Arte coupled with the narrow profile design is a natural for window walls where the mullions are small and the minimal glass to glass dimension are critical to the clean, crisp geometric look of the aesthetic.
THERMALLY-BROKEN PERFORMANCE WITH NARROW SIGHT LINES
![Page 3: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/3.jpg)
OVERVIEWSteel-Arte Introduction 2Why Choose Dynamic Steel? 4Steel-Arte Glazing Flexibility 4High Performance Dual or Triple Insulating Glass 4Historic Authenticity with Lead Glass Overlay 5NFRC Certified Glazing Performance 5AAMA & ASTM Testing: Proven Window & Door Performance 5
WINDOW DETAILSOUTSWING Casement - Venting or fixed configurations 7 French Casement 8
www.dynamicwindows.com
INDEX
Page
Awning 10 Awning in Typical Window Wall 11INSWING Casement - Venting or fixed configurations 13 French Casement 14 Hopper 16Direct Glazed 17
DOOR DETAILSOUTSWING Steel-Arte Door 19 Stile & Rail Door 21INSWING Steel-Arte Door 24 Stile & Rail Door 26
OPTIONS & ACCESSORIESTraditional Casement Profile - for Historic Appplications 29Mullion Reinforcement Options 30Radius Profiles 31Drip Cap Options 32Window Hardware Options 33Glazing Stop Options 36
WINDOW WALL EXAMPLES S1 Glazing Stop Details 38 S3 Glazing Stop Details 50 Steel “L” Glazing Stop Details 56Typical Installation Details 64
![Page 4: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/4.jpg)
Back to Index - 4www.dynamicwindows.com
Narrow profiles that would meet the aesthetic design criteria of both the luxury residential andhistorical replacements markets.
Thermally broken frames and sash that wouldreduce the potential for room-side condensation (a repetitive problem with conventional non-thermally broken steel windows).
Window and door designs that accommodate a wide range of double and triple glazed options,to meet each unique project requirement.
Third party tested window designs that meetthe evolving energy codes, complete with NFRCand AMMA testing.
Optional third party structural engineering services to provide an extra level of confidence in project specific design performance.
An industry leading business model with depend-able & accurate lead time estimates, concise communication, timely turnaround of shop drawings and clearly defined expectations in all aspects of the window designing and manufactur-ing process. Dynamic is known for the ability to meet the expectations of this demanding niche.
Over the last 20 years Dynamic Architectural Windows & Doors has manufactured custom windows and doors for hundreds of the finest architecturally designed luxury homes and historical restorations in North America. It was only after repeated requests from our best architect and builder customers that Dynamic made the decision to add steel windows and doors to the manufacturing line up. Our customers provided us with a detailed wish list of what wasneeded in the steel window industry in North America.
Their steel wish list included the following:
WHY CHOOSE DYNAMIC STEEL?
The 1 3/4” overall glazing cavity accommodates an unlim-ited combination of high performance glass types, thick-nesses and spacer bar materials. Whether it’s thermal performance, sound abatement, security or a combination of performance objectives the flexibility is available to meet the most stringent performance specifications.
STEEL-ARTE GLAZING FLEXIBILITY HIGH PERFORMANCE DUAL OR TRIPLEINSULATING GLASS
Narrow sightlines, superior strength and unmatched durability have long been the attractive design components of using steel windows & doors, but these attributes have been often overshadowed by the potential of condensation and poor thermal efficiency.
Dynamic Steel-Arte introduces a unique solution to these design concerns with thermally broken frame & sash components coupled with unmatched glazing flexibility.
The glazing flexibility is an important component of a steel window or doors overall performance. The oversized glaz-ing cavity of the Steel-Arte thermally broken frame & sash allows facilitates glass thicknesses up to 1 3⁄4 inches.
·
·
·
·
·
·
![Page 5: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/5.jpg)
Back to Index - 5www.dynamicwindows.com
The use of applied lead or zinc overlays is a proven technique for replicating the appearance of true leaded glass without the expense and performance issues associated with traditional metal caming or leaded glass.
Dynamic takes Lead Glass Overlay to a higher level by applying the lead or zinc to the exterior and room side of the insulating glass and includes a metal spacer between the two insulating glass surfaces. The internal grid appear-ance is authentic and when coupled with warm edge spacer bars, argon gas, and a variety of low E coatings; the final performance will meet any of today’s stringentenergy codes.
Available in a selection of widths and patina colors, the use of Lead or Zinc Glass Overlay with an internal grid is an excellent solution for both historical replacements or luxury residential homes where a narrow muntin is important.
HISTORIC AUTHENTICITY WITH LEAD GLASS OVERLAY
In addition to the complete range of European performance testing completed by our Swiss partner at the time of initial design, Dynamic Steel-Arte windows and doors have also independently lab tested for Air, Water, and Structural performance using the recognized North American standard AAMA / WDMA / CSA / 101 / IS2 / A440.
NFRC CERTIFIED GLAZING PERFORMANCE
AAMA & ASTM TESTING: PROVEN WINDOW & DOOR PERFORMANCE
Dynamic Steel-Arte is one of the few steel windows & doors on the market today that are tested and certified to the NFRC (National Fenestration RatingCouncil) performance standards. In many areasof the country the state and local building codesare requiring verifiable glazing performance usingthe NFRC certified labels on each product.
![Page 6: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/6.jpg)
Back to Index - 6
WINDOW ELEVATIONS
www.dynamicwindows.com
Venting or fixed configurations
Venting or fixed configurations
Inswing Casement
Outswing Casement
Inswing French Casement
Outswing French Casement
Outswing Awning in Window Wall
Outswing Awning
Inswing HopperDirect Glazed
SECTIONAL DETAILS FOR EACH DESIGN IS
INCLUDED IN THIS OVERVIEW. THESE ARE
THE STANDARD DETAILS. FOR ADDITIONAL
DESIGN FLEXIBILITY QUESTIONS CALL THE
DYNAMIC SALES TEAM AT 1.800.661.8111
![Page 7: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/7.jpg)
L profile Z profile h profile
CONFIGURATION: VENTING OR FIXED
Back to Index - 7
OUTSWING CASEMENT
1
2
3
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING CASEMENT MAX. VENTING DIMENSIONS: 31 1/2 “ X 63”
www.dynamicwindows.com
![Page 8: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/8.jpg)
L profile Z profile h profile
Back to Index - 8
OUTSWING FRENCH CASEMENT
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING FRENCH CASEMENT MAX. DIMENSIONS: 63“ X 63”
www.dynamicwindows.com
1
2
3
4
![Page 9: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/9.jpg)
L profile Z profile h profile
Back to Index - 9
OUTSWING FRENCH CASEMENT
MEETING STILE DETAILS4
OUTSWING FRENCH CASEMENT MAX. DIMENSIONS: 63“ X 63”
www.dynamicwindows.com
1
2
3
4
![Page 10: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/10.jpg)
L profile Z profile h profile
Back to Index - 10
OUTSWING AWNING
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING AWNING MAX. DIMENSIONS: 63” x 31 1/2“
www.dynamicwindows.com
1
2
3
![Page 11: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/11.jpg)
L profile Z profile h profile
Back to Index - 11
OUTSWING AWNING IN WINDOW WALL
AWNING HEAD DETAIL1
AWNING SILL DETAIL2
AWNING JAMB DETAIL3
OUTSWING AWNING IN WINDOW WALL MAX. DIMENSIONS (AWNING): 63” x 31 1/2“
www.dynamicwindows.com
1
23
4
![Page 12: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/12.jpg)
L profile Z profile h profile
Back to Index - 12
OUTSWING AWNING IN WINDOW WALL
OUTSIDE JAMB DETAILS4
OUTSWING AWNING IN WINDOW WALL MAX. DIMENSIONS (AWNING): 63” x 31 1/2“
www.dynamicwindows.com
1
23
4
![Page 13: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/13.jpg)
L profile Z profile h profile
CONFIGURATION: VENTING OR FIXED
Back to Index - 13
INSWING CASEMENT
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING CASEMENT MAX. VENTING DIMENSIONS: 31 1/2 “ X 63”
www.dynamicwindows.com
1
2
3
![Page 14: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/14.jpg)
L profile Z profile h profile
Back to Index - 14
INSWING FRENCH CASEMENT
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING FRENCH CASEMENT MAX. DIMENSIONS: 63“ X 63”
www.dynamicwindows.com
1
2
3
4
![Page 15: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/15.jpg)
L profile Z profile h profile
Back to Index - 15
INSWING FRENCH CASEMENT
MEETING STILE DETAILS4
INSWING FRENCH CASEMENT MAX. DIMENSIONS: 63“ X 63”
www.dynamicwindows.com
1
2
3
4
![Page 16: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/16.jpg)
L profile Z profile h profile
Back to Index - 16
INSWING HOPPER
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING HOPPER MAX. DIMENSIONS: 63“ X 31 1/2”
www.dynamicwindows.com
1
2
3
![Page 17: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/17.jpg)
L profile Z profile h profile
Back to Index - 17
DIRECT GLAZED
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
DIRECT GLAZED
www.dynamicwindows.com
1
2
3
![Page 18: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/18.jpg)
Back to Index - 18
DOOR ELEVATIONS
www.dynamicwindows.com
Inswing steel-arteDoor
Inswing steel-arteDouble Door
Outswing steel-arteDouble Door
Outswing steel-arteDoor
Inswing Stile & Rail Door
Inswing Stile & Rail Double Door
Outswing Stile & Rail Double Door
Outswing Stile & Rail Door
STEEL-ARTE DOOR SERIES
STILE & RAIL DOOR SERIES
MAX. DOOR HEIGHT: 108”MAX. DOOR WIDTH: 36” (PER SLAB)
MAX. DOOR HEIGHT: 120”MAX. DOOR WIDTH: 48” (PER SLAB)
![Page 19: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/19.jpg)
MAX. DOOR WIDTH: 36”
Back to Index - 19
OUTSWING STEEL-ARTE DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING STEEL-ARTE DOOR MAX. DOOR HEIGHT: 108”
www.dynamicwindows.com
1
2
3
![Page 20: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/20.jpg)
MAX. DOOR WIDTH: 36” (PER SLAB)
Back to Index - 20
OUTSWING STEEL-ARTE DOUBLE DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING STEEL-ARTE DOUBLE DOOR MAX. DOOR HEIGHT: 108”
www.dynamicwindows.com
1
2
3
![Page 21: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/21.jpg)
MAX. DOOR WIDTH: 50”
Back to Index - 21
OUTSWING STILE & RAIL DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING STILE & RAIL DOOR MAX. DOOR HEIGHT: 120”
www.dynamicwindows.com
1
2
3
varies
medium exposure threshold
check valve for drainageunder positive pressure
thresholds available in aluminum, bronze or assorted hardwoods
1 3/16"
1 3/16"
2 3/8"
13/16"
1 9/16"
13/16"
1 9/16"
1 9/16"
9/16"
3 7
/16"
7/8"
3 7
/16"
1/4"
var
ies
3 7/8"
1 1/8"
1 9/16" 1 9/16" 13/16" 13/16" 1 9/16" 1 9/16"
3 7/16"
2 3/8
"1 3/16"
3 7/16"
2 3/8
"
![Page 22: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/22.jpg)
MAX. DOOR WIDTH: 48” (PER SLAB)
Back to Index - 22
OUTSWING STILE & RAIL DOUBLE DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
OUTSWING STILE & RAIL DOUBLE DOOR MAX. DOOR HEIGHT: 120”
www.dynamicwindows.com
varies
medium exposure threshold
check valve for drainageunder positive pressure
thresholds available in aluminum, bronze or assorted hardwoods
1 3/16"
1 3/16"
2 3/8"
13/16"
1 9/16"
13/16"
1 9/16"
1 9/16"
9/16"
3 7
/16"
7/8"
3 7
/16"
1/4"
var
ies
3 7/8"
1 1/8"
1 9/16" 1 9/16" 13/16" 2 9/16" 1 9/16" 13/16"13/16" 13/16" 1 9/16" 1 9/16"
1 3/16"
2 3/8
"
3 7/16"3 7/16"3 7/16" 2 7/16"
1 3/16"
2 3/8
"1
2
4
3
![Page 23: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/23.jpg)
MAX. DOOR WIDTH: 48” (PER SLAB)
Back to Index - 23
OUTSWING STILE & RAIL DOUBLE DOOR
LOCKSET DETAILS4
OUTSWING STILE & RAIL DOUBLE DOOR MAX. DOOR HEIGHT: 120”
www.dynamicwindows.com
1
2
4
3
3 7/16"2 7/16" 3 7/16"
![Page 24: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/24.jpg)
MAX. DOOR WIDTH: 36”
Back to Index - 24
INSWING STEEL-ARTE DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING STEEL-ARTE DOOR MAX. DOOR HEIGHT: 108”
www.dynamicwindows.com
1
2
3
saddle secured to floor sill with drop down sweep
![Page 25: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/25.jpg)
MAX. DOOR WIDTH: 36” (PER SLAB)
Back to Index - 25
INSWING STEEL-ARTE DOUBLE DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING STEEL-ARTE DOUBLE DOOR MAX. DOOR HEIGHT: 108”
www.dynamicwindows.com
saddle secured to floor sill with drop down sweep
1
2
3
![Page 26: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/26.jpg)
MAX. DOOR WIDTH: 50”
Back to Index - 26
INSWING STILE & RAIL DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING STILE & RAIL DOOR MAX. DOOR HEIGHT: 120”
www.dynamicwindows.com
medium exposure threshold
thresholds available in aluminum, bronze or assorted hardwoods
2 3/8"
9/16"
2 9/16"
13/16"2
7/16
"1 9/16"
1 3/16"
1 3/16"7/8"
2 7/
8"
2 9/16"
13/16"
3/16"
1 9/16"
1 1/8"
7 1/8"
4 3/4"
9/16" 2 9/16" 13/16" 2 9/16"13/16"
1 13
/16"
2 3/8
"
9/16"
2 7/16" 1 9/16"2 7/16"1 9/16"
2 3/8
"
1
2
3
![Page 27: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/27.jpg)
MAX. DOOR WIDTH: 48” (PER SLAB)
Back to Index - 27
INSWING STILE & RAIL DOUBLE DOOR
HEAD DETAILS1
SILL DETAILS2
JAMB DETAILS3
INSWING STILE & RAIL DOUBLE DOOR MAX. DOOR HEIGHT: 120”
www.dynamicwindows.com
medium exposure threshold
thresholds available in aluminum, bronze or assorted hardwoods
2 3/8"
9/16"
2 9/16"
13/16"2
7/16
"1 9/16"
1 3/16"
1 3/16"7/8"
2 7/
8"
2 9/16"
13/16"
3/16"
1 9/16"
1 1/8"
7 1/8"
4 3/4"
9/16" 2 9/16" 13/16" 13/16" 2 9/16" 13/16"1 9/16" 13/16" 2 9/16"
2 3/8
"
2 7/16" 1 9/16"2 7/16" 3 7/16"
1 3/16"
2 7/16"1 9/16"
2 3/8
"1
2
3
4
![Page 28: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/28.jpg)
MAX. DOOR WIDTH: 48” (PER SLAB)
Back to Index - 28
INSWING STILE & RAIL DOUBLE DOOR
LOCKSET DETAILS4
INSWING STILE & RAIL DOUBLE DOOR MAX. DOOR HEIGHT: 120”
www.dynamicwindows.com
2 7/16" 2 7/16"3 7/16"
1
2
3
4
![Page 29: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/29.jpg)
Back to Index - 29www.dynamicwindows.com
For over 20 years Dynamic Architectural Windows & Doors has worked closely with landmark associationsand numerous historic preservation authorities to developunique solutions for historically significant buildingsacross North America.
With the introduction of the Steel-Arte line of products that commitment continues with the new Traditional Casement Profile. This traditional profile delivers the same tested performance and thermally-broken benefits of the other Steel-Arte designs and adds the exterior shadow lines of the historic putty profiles of yesterday.
TRADITIONAL CASEMENT PROFILE FOR HISTORIC APPLICATIONS
![Page 30: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/30.jpg)
Back to Index - 30www.dynamicwindows.com
MULLION REINFORCEMENT OPTIONS FACTORY -APPLIED, LASER WELDED
≥ 3/16”
varie
s
≥ 3/16”va
ries
3/8”
varie
s
1/16”
varie
s
1 9/16”
1/16”
≥ 3/16”
varie
s
varie
s
3/8”
1/16”
varie
s
1/16”
3/8”
1 2 3
4
7 8 9
5 6
2”
2”
1”1”
2 1/8”
1” 1”1/8”
laser welded "L" profile mechanically fastened "L"profile
![Page 31: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/31.jpg)
Back to Index - 31www.dynamicwindows.com
RADIUS PROFILES
1
1 2 3
2 3
R
R
R
16”R
R 16”
RMinimum
RMinimum
16”
16”
16”
* NOTE: MINIMUM RADIUS IS THE SAME ON THE "L", "Z" AND "H" THERMALLY BROKEN PROFILES
frame only inswing designs outswing designs
TypeGlazingStop
![Page 32: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/32.jpg)
Back to Index - 32www.dynamicwindows.com
DRIP CAP OPTIONS
L profile Z profile h profile
DRIP CAPS ARE OPTIONAL ON OUTSWING PROFILES
DRIP CAPS ARE REQUIRED ON INSWING PROFILES
![Page 33: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/33.jpg)
Back to Index - 33www.dynamicwindows.com
WINDOW HARDWARE OPTIONS
TYPE 1 HANDLE - STEEL-ARTE TRADITIONAL CAM HANDLE
TYPE 2 HANDLE - STEEL-ARTE CONTEMPORARY CAM HANDLE
![Page 34: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/34.jpg)
Back to Index - 34www.dynamicwindows.com
WINDOW HARDWARE OPTIONS
TYPE 3 HANDLE - STEEL-ARTE EURO CAM HANDLE
![Page 35: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/35.jpg)
Back to Index - 35www.dynamicwindows.com
WINDOW HARDWARE OPTIONS
CASEMENT HINGE OPTIONS
STEEL-ARTE CASEMENT WELDED HINGE
STEEL-ARTE CASEMENT SCREW-ON HINGE
STEEL-ARTE CASEMENT EXTENDED HINGE
![Page 36: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/36.jpg)
Back to Index - 36www.dynamicwindows.com
ALUMINUM GLAZING STOP OPTIONS
1”
9/16
”1/8”
13/16”
9/16
”1/8”
9/16”
9/16
”1/8”
S1 S2 S3TYPE TYPE TYPE
1 3/16”
9/16
”
S4TYPE
![Page 37: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/37.jpg)
Back to Index - 37www.dynamicwindows.com
STEEL GLAZING STOP OPTION
“L ” STOP
varie
s9/16”
5/32”
REGLETS WITH DIFFERENT CONTOURS & GLASS THICKNESSES
Steel-Arte “L” glass stop creates interesting reglets & contours for a unique contemporary or industrialappearance
![Page 38: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/38.jpg)
Back to Index - 38www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING WINDOW WALL
5/32” 5/32”
1 9/16”
9/16”3/8”9/16”
1”
9/16”3/8”
1 - H FRAME PROFILE 1 - L FRAME PROFILE
11
3
2
3 5
1
5
4
1
4
22
777
2
2
3 3
1
6
2
1
6
![Page 39: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/39.jpg)
Back to Index - 39www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING WINDOW WALL
5/32”3/8”
2 3/8”1 9/16”
9/16”3/8”9/16”
2 3
4 55/32”3/8”5/32” 5/32”3/8”5/32”
45/64”
2 3/8”
17/64” 9/16”13/16”9/16”3/8”9/16”
2 3/8”
13/16”
5/32”5/32”
9/16” 3/8” 9/16”13/16”
![Page 40: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/40.jpg)
Back to Index - 40www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING WINDOW WALL
9/16
”3/
8”9/
16”
2 3/
8”
13/1
6”
2 3/
8”
13/1
6”
6
7
9/16
”9/
16”
3/8”
3/8”
5/32
”5/
32”
3/8”
5/32
”
![Page 41: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/41.jpg)
Back to Index - 41www.dynamicwindows.com
S1 GLAZING STOP DETAILS INSWING WINDOW WALL
5/32” 5/32”
1 9/16”
9/16”3/8”9/16”
1”
9/16”3/8”
1 - H FRAME PROFILE 1 - L FRAME PROFILE
1
1
1 1
2
2 412
6
1
4
3
3
6 6
2 5 5
![Page 42: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/42.jpg)
Back to Index - 42www.dynamicwindows.com
S1 GLAZING STOP DETAILS INSWING WINDOW WALL
5/32”
5/32”3/8”
2 3/8”
13/16”9/16”3/8”9/16”
1 9/16”
9/16”3/8”9/16”
1 - T FRAME PROFILE 2 - H FRAME PROFILE
3 - T FRAME WITH SASH 45/32”3/8”5/32”
5/32”3/8”5/32”
13/16” 45/64”
2 3/8”
17/64” 9/16”13/16”
2 3/8”
9/16”3/8”9/16”
![Page 43: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/43.jpg)
Back to Index - 43www.dynamicwindows.com
S1 GLAZING STOP DETAILS INSWING WINDOW WALL
13/1
6”
2 3/
8”
9/16
”3/
8”9/
16”
5
9/16
”3/
8”9/
16”
3/8”
2 3/
8”
5/32
”
6
3/8”
5/32
”5/
32”
13/1
6”
![Page 44: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/44.jpg)
Back to Index - 44www.dynamicwindows.com
S1 GLAZING STOP DETAILS INSWING CASEMENT
1 9/16”1 9/16” 1 9/16”
1 9/16” 1 9/16” 1 9/16”
5/32”
5/32” 5/32”
5/32”
5/32” 5/32” 5/32” 5/32” 5/32”
1 9/16”
5/32” 5/32”
1 9/16”
5/32”
13/16”1 9/16”
5/32”
13/16” 1 9/16”
5/32”
5/32” 5/32”
2 3/8” 2 3/8”
3/16”
A
D
A
D
BB
C
C
A - A
B - B
![Page 45: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/45.jpg)
Back to Index - 45www.dynamicwindows.com
S1 GLAZING STOP DETAILS INSWING CASEMENT
1 9/
16”
1 9/
16”
1 9/
16”
1 9/
16”
1 9/
16”
1 9/
16”
5/32
”5/
32”
5/32
”1
9/16
”5/
32”
5/32
”5/
32”
5/32
”1
9/16
”5/
32”
5/32
”5/
32”
5/32
”
13/1
6”
3/16
”3/
16”
1 9/
16”
5/32
”5/
32”
5/32
”
1 9/
16”
2 3/
8”13
/16”
2 3/
8”
C - C D - D
![Page 46: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/46.jpg)
Back to Index - 46www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING CASEMENT
1 9/16”5/32”
13/16”
2 3/8”
1 9/16” 1 9/16” 1 9/16”5/32” 5/32” 5/32” 5/32” 5/32”
1 9/16”5/32” 5/32”
1 9/16”5/32”
1 9/16”1 9/16” 1 9/16”
5/32”5/32”5/32”
5
5/32” 5/32”
A - A
B - B
13/16”2 3/8”
1 9/16”5/32” 5/32”
A
D
A
D
BB
C
C
![Page 47: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/47.jpg)
Back to Index - 47www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING CASEMENT
1 91
6”1
916”
1 91
6”5/
32”
5/32
”5/
32”
5/32
”5/
32”
1 91
6”5/
32”
5/32
”1
916”
5/32
”1 91
6”5/
32”
13/1
6”2
3/8”
1 91
6”1
916”
1 91
6” 5/32
”5/
32”
13/1
6”2
3/8” 1 91
6”
3/16
”3/
16”
5/32
”5/
32”
5/32
”
C - C D - D
5/32
”
![Page 48: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/48.jpg)
Back to Index - 48www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING AWNING
1 9/16”
9/16” 3/8” 9/16”
1 9/16” 1 9/16”1 9/16”
1 9/16” 1 9/16” 1 9/16”
5/32”
1 9/16”13/16”
5/32” 5/32” 5/32” 5/32”
13/16”
5/32”5/32” 5/32”
3/16”3/16”
5/32” 5/32” 5/32” 5/32” 5/32”
1 9/16”
5/32” 5/32”
1 9/16”
5/32”
A - A
B - B
A
D
A
D
BB
C
C
![Page 49: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/49.jpg)
Back to Index - 49www.dynamicwindows.com
S1 GLAZING STOP DETAILS OUTSWING AWNING
1 9/
16”
1 9/
16”
13/1
6”2
3/8”
1 9/
16”
1 9/
16”
1 9/
16”
1 9/
16”
5/32
”5/
32”
5/32
”1
9/16
”5/
32”
5/32
”5/
32”
5/32
”1
9/16
”5/
32”
5/32
”5/
32”
5/32
”5/
32”
5/32
”
3/16
”
1 9/
16”
C - C D - D
13/1
6”2
3/8”
5/32
”5/
32”
1 9/
16”
![Page 50: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/50.jpg)
Back to Index - 50www.dynamicwindows.com
S3 GLAZING STOP DETAILS OUTSWING WINDOW WALL
11
3
2
3 5
1
5
4
1
4
22
777
2
2
3 3
1
6
2
1
6
5/32”5/32”
1 9/16”
9/16”3/8”9/16”
1”
3/8” 9/16”
1 - H FRAME PROFILE 1 - L FRAME PROFILE
![Page 51: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/51.jpg)
Back to Index - 51www.dynamicwindows.com
S3 GLAZING STOP DETAILS OUTSWING WINDOW WALL
5/32”3/8”
2 3/8”
1 9/16”
9/16”3/8”9/16”
2 3
4 55/32”3/8”5/32” 5/32”3/8”5/32”
45/64”
2 3/8”
17/64” 9/16”13/16”9/16”3/8”9/16”
2 3/8”
13/16”
5/32” 5/32”
9/16” 9/16”3/8”13/16”
![Page 52: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/52.jpg)
Back to Index - 52www.dynamicwindows.com
S3 GLAZING STOP DETAILS OUTSWING WINDOW WALL
9/16
”3/
8”9/
16”
2 3/
8”
13/1
6”
2 3/
8”
13/1
6”
6
7
13/1
6”13
/16”
13/1
6” 5/32
”3/
8”5/
32”
3/8”
5/32
”
![Page 53: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/53.jpg)
Back to Index - 53www.dynamicwindows.com
S3 GLAZING STOP DETAILS INSWING WINDOW WALL
1
1
1 1
2
2 412
6
1
4
3
3
6 6
2 5 5
1 9/16”
9/16”3/8”9/16”
1”
3/8” 9/16”
1 - H FRAME PROFILE 1 - L FRAME PROFILE
![Page 54: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/54.jpg)
Back to Index - 54www.dynamicwindows.com
S3 GLAZING STOP DETAILS INSWING WINDOW WALL
5/32” 3/8”
5/32”
2 3/8”
13/16”3/8” 9/16”9/16”
1 9/16”
9/16”3/8”9/16”
1 - T FRAME PROFILE 2
5/32”3/8”5/32” 5/32” 3/8”5/32”
13/16” 45/64”
2 3/8”
17/64” 9/16”13/16”
2 3/8”
3/8” 9/16”9/16”
3 - T FRAME WITH SASH 4
![Page 55: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/55.jpg)
Back to Index - 55www.dynamicwindows.com
S3 GLAZING STOP DETAILS INSWING WINDOW WALL
3/8”
2 3/
8”
13/1
6”9/
16”
3/8”
9/16
”13
/16”
2 3/
8”
9/16
”9/
16”
3/8”
5
6
5/32
”3/
8”5/
32”
5/32
”
![Page 56: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/56.jpg)
Back to Index - 56www.dynamicwindows.com
L GLAZING STOP DETAILS OUTSWING WINDOW WALL
11
3
2
3 5
1
5
4
1
4
22
777
2
2
3 3
1
6
2
1
6
5/23” 5/23”
1 9/16”
9/16”3/8”9/16”
1”
9/16”3/8”
1 - H FRAME PROFILE 1 - L FRAME PROFILE
![Page 57: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/57.jpg)
Back to Index - 57www.dynamicwindows.com
L GLAZING STOP DETAILS OUTSWING WINDOW WALL
5/32”3/8”
2 3/8”1 9/16”
9/16”3/8”9/16”
2 3
4 55/32”3/8”5/32”
5/32”3/8”5/32”
45/64”
2 3/8”
17/64” 9/16”13/16”9/16”3/8”9/16”
2 3/8”
13/16”
5/32”5/32”
9/16” 3/8” 9/16”13/16”
![Page 58: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/58.jpg)
Back to Index - 58www.dynamicwindows.com
L GLAZING STOP DETAILS OUTSWING WINDOW WALL
5/32
”3/
8”
9/16
”3/
8”9/
16”
2 3/
8”
13/1
6”
2 3/
8”
13/1
6”
6
7
9/16
”3/
8”9/
16” 5/
32”
3/8”
5/32
”
![Page 59: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/59.jpg)
Back to Index - 59www.dynamicwindows.com
L GLAZING STOP DETAILS INSWING WINDOW WALL
5/32” 5/32”
1 9/16”
9/16”3/8”9/16”
1”
9/16”3/8”
1 - H FRAME PROFILE 1 - L FRAME PROFILE
1
1
1 1
2
2 412
6
1
4
3
3
6 6
2 5 5
![Page 60: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/60.jpg)
Back to Index - 60www.dynamicwindows.com
L GLAZING STOP DETAILS INSWING WINDOW WALL
5/32”
2 3/8”
13/16”9/16”3/8”9/16”
1 9/16”
9/16”3/8”9/16”
1 - T FRAME PROFILE 2 - H FRAME PROFILE
3 - T FRAME WITH SASH 45/32”3/8”5/32” 5/32”3/8”5/32”
13/16” 45/64”
2 3/8”
17/64” 9/16”13/16”
2 3/8”
9/16”3/8”9/16”
5/32”3/8”
![Page 61: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/61.jpg)
Back to Index - 61www.dynamicwindows.com
L GLAZING STOP DETAILS INSWING WINDOW WALL
2 3/
8”
9/16
”3/
8”9/
16”
3/8”
13/1
6”
5/32
”
13/1
6”
2 3/
8”
9/16
”3/
8”9/
16”
5
6
5/32
”5/
32”
3/8”
![Page 62: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/62.jpg)
Back to Index - 62www.dynamicwindows.com
L GLAZING STOP DETAILS INSWING CASEMENT
1 9/16” 1 9/16”
1 9/16” 1 9/16” 1 9/16”
5/32” 5/32”
5/32” 5/32” 5/32” 5/32” 5/32”1 9/16”
5/32” 5/32”1 9/16”
5/32”
13/16”1 9/16”5/32”
13/16” 1 9/16”5/32”
3/16”
5/32”
2 3/8”
5/32” 5/32”13/16”
45/64”17/64” 9/16”
5/32”
2 3/8”
A
D
A
D
BB
C
C
A - A
B - B
![Page 63: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/63.jpg)
Back to Index - 63www.dynamicwindows.com
L GLAZING STOP DETAILS INSWING CASEMENT
1 9/
16”
1 9/
16”
1 9/
16”
5/32
”5/
32”
5/32
”13
/16”
3/16
”3/
16”
1 9/
16”
5/32
”5/
32”
5/32
”
1 9/
16”
1 9/
16”
1 9/
16”
5/32
”5/
32”
5/32
”5/
32”
5/32
”1
9/16
”5/
32”
5/32
”1
9/16
”5/
32”
5/32
”
1 9/
16”
13/1
6”2
3/8”
2 3/
8”
C - C D - D
![Page 64: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/64.jpg)
Back to Index - 64www.dynamicwindows.com
TYPICAL INSTALLATION DETAILS
3/64
”
3/64
”
1” 1”
2 3/16”
3/16”
9/16
”3/
8”9/
16”
1 9/
16”
9/16” 3/8” 9/16”
1 9/16”
3/64”
3/8”
9/16
”
1”
3/8” 9/16”
1”
3/64”
9/16” x 9/16”
Direct Glazed Mullion
Direct Glazed Corner Mulling Options
DISCLAIMER: THESE INSTRUCTIONS AND METHODS MAY NOT BE APPROPRIATE FOR A SPECIFIC INSTALLATION DUE TO DESIGN OF THE BUILDING, CONSTRUCTION METHODS USED, BUILDING CONDITIONS OR SITE CONDITIONS, ANY OF WHICH MAY REQUIRE DIFFERENT METHODS OR PROCEDURES. THE ARCHITECT, BUILDING ENVELOPE SPECIALIST OR INSTALLATION CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE INSTALLATION METHOD AND PROCEDURE FOR PROJECT SPECIFIC INSTALLATIONS. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES.
![Page 65: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/65.jpg)
Back to Index - 65www.dynamicwindows.com
TYPICAL INSTALLATION DETAILS
DISCLAIMER: THESE INSTRUCTIONS AND METHODS MAY NOT BE APPROPRIATE FOR A SPECIFIC INSTALLATION DUE TO DESIGN OF THE BUILDING, CONSTRUCTION METHODS USED, BUILDING CONDITIONS OR SITE CONDITIONS, ANY OF WHICH MAY REQUIRE DIFFERENT METHODS OR PROCEDURES. THE ARCHITECT, BUILDING ENVELOPE SPECIALIST OR INSTALLATION CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE INSTALLATION METHOD AND PROCEDURE FOR PROJECT SPECIFIC INSTALLATIONS. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES.
![Page 66: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/66.jpg)
Back to Index - 66www.dynamicwindows.com
TYPICAL INSTALLATION DETAILS
DISCLAIMER: THESE INSTRUCTIONS AND METHODS MAY NOT BE APPROPRIATE FOR A SPECIFIC INSTALLATION DUE TO DESIGN OF THE BUILDING, CONSTRUCTION METHODS USED, BUILDING CONDITIONS OR SITE CONDITIONS, ANY OF WHICH MAY REQUIRE DIFFERENT METHODS OR PROCEDURES. THE ARCHITECT, BUILDING ENVELOPE SPECIALIST OR INSTALLATION CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE INSTALLATION METHOD AND PROCEDURE FOR PROJECT SPECIFIC INSTALLATIONS. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES.
![Page 67: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/67.jpg)
Back to Index - 67www.dynamicwindows.com
TYPICAL INSTALLATION DETAILS
DISCLAIMER: THESE INSTRUCTIONS AND METHODS MAY NOT BE APPROPRIATE FOR A SPECIFIC INSTALLATION DUE TO DESIGN OF THE BUILDING, CONSTRUCTION METHODS USED, BUILDING CONDITIONS OR SITE CONDITIONS, ANY OF WHICH MAY REQUIRE DIFFERENT METHODS OR PROCEDURES. THE ARCHITECT, BUILDING ENVELOPE SPECIALIST OR INSTALLATION CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE INSTALLATION METHOD AND PROCEDURE FOR PROJECT SPECIFIC INSTALLATIONS. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES.
![Page 68: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/68.jpg)
Back to Index - 68www.dynamicwindows.com
TYPICAL INSTALLATION DETAILS
DISCLAIMER: THESE INSTRUCTIONS AND METHODS MAY NOT BE APPROPRIATE FOR A SPECIFIC INSTALLATION DUE TO DESIGN OF THE BUILDING, CONSTRUCTION METHODS USED, BUILDING CONDITIONS OR SITE CONDITIONS, ANY OF WHICH MAY REQUIRE DIFFERENT METHODS OR PROCEDURES. THE ARCHITECT, BUILDING ENVELOPE SPECIALIST OR INSTALLATION CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE INSTALLATION METHOD AND PROCEDURE FOR PROJECT SPECIFIC INSTALLATIONS. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES.
1 3/16” x 1 3/16”
![Page 69: ARCHITECTURE IN STEEL - Dynamic Windows & Doors · glass without the expense and performance issues associated with traditional metal caming or leaded glass. Dynamic takes Lead Glass](https://reader033.fdocuments.us/reader033/viewer/2022041502/5e2251aab536f5261169fd44/html5/thumbnails/69.jpg)
Dynamic Architectural Windows & Doors30440 Progressive WayAbbotsford, BC Canada V2T 6W3Toll Free 1.800.661.8111 or email [email protected] (604) 864.6072www.dynamicwindows.com
© Copyright 2012 Dynamic Architectural Windows & Doors. All rights reserved.
®