Technical Memorandum Fort Mims Drive | Maryland Heights, Missouri March 24, 2017 | Geotechnology Project No. J024002.03
2
Laboratory Testing of C-14 Soil Leaching Potential DDES performed additional soil sampling and testing at four selected site sampling locations based on C-14 concentrations. The additional soil sampling was performed approximately two feet to the north, south, east, and west of the original locations summarized below. Soil samples were collected at 1 meter (m) and 2 m depths (32 soil samples for laboratory leaching test). Original Soil Sample Location
047 049 051 061
Each of the 32 soil samples were tested for C-14. In addition, laboratory representatives added 100 ml of deionized water to a 30 gram aliquot of each soil sample. After sitting for a minimum of 12 hours, the deionized water was decanted from the soil mixture and analyzed for C-14. The laboratory leaching process that was performed provides a general indication of the C-14 desorption potential exhibited by site soils. The laboratory testing report that documents the soil and water testing results for the laboratory leachate procedure is provided in Attachment 1. A table summarizing the leaching results is provided in Attachment 2. We understand that the laboratory reported the liquid testing results on a weight of liquid basis (i.e., pCi/g). Thirteen of the 32 soil and leachate samples exhibited C-14 concentrations above detection limits in both the soil and leachate sample. Notably, 19 of the 32 soil and leachate samples exhibited C-14 concentrations below detection limits in the soil and/or leachate sample. Kd values of the 13 samples range from 0.7 to 74.1 with an average Kd value (desorption) of 29.9. A plot of the C-14 concentrations of the 13 soil samples in relation to desorption C-14 Kd values is provided in Attachment 2. The data plot indicates a correlation between higher soil C-14 concentrations and higher Kd values. Although there are some limitations in the laboratory leaching process, the leachate testing results show overall that C-14 preferentially remains in the soil phase. Some leaching or desorption of C-14 from the site soil samples is indicated by the laboratory leaching process and by the groundwater testing results presented herein.
Technical Memorandum Fort Mims Drive | Maryland Heights, Missouri March 24, 2017 | Geotechnology Project No. J024002.03
3
C-14 Concentrations in Soil Site maps prepared by DDES, LLC (DDES) that summarize C-14 concentrations in soil at depths of 0.15 meter (m), 1 m, 2 m, and 3 m are provided in Attachment 3. The data shown on the site maps indicate that C-14 concentrations in soil generally decrease with sampling depth and that substantial amounts of C-14 is adsorbed to or otherwise retained in soil at depths less than 3 m. In our opinion, the reduced frequency and concentration of C-14 detections in the deeper soil samples (3 m depth) support that extensive leaching or desorption of C-14 is not occurring from shallow soils at the site. C-14 Concentrations in Groundwater Site maps showing groundwater elevations and C-14 concentrations exhibited in groundwater samples collected from on site and off site monitoring wells are provided in Attachment 4. Detected C-14 concentrations in groundwater range from approximately 11.8 pCi/L (MW-6) to 647 pCi/L (MW-3). Groundwater samples collected from off-site Monitoring Wells MW-7 and MW-8 did not exhibit detectable C-14 concentrations. As noted above, the limited number of C-14 detections in the deeper soil samples support that C-14 desorption from shallow soil and vertical migration of C-14 through the soil is not the only process contributing to detections of C-14 in groundwater. In our opinion, the former on-site septic tank operation likely contributed to the observed C-14 groundwater concentrations. Operation of the septic tank ceased approximately 30 years ago (1986). In relation to the laboratory desorption C-14 Kd information presented herein, the average C-14 groundwater concentrations (151 pCi/L or 0.151 pCi/ml) at source area Monitoring Wells MW-2, -3, and -4 combined with representative average site specific C-14 soil concentrations (26.28 pCi/g) supports that site specific Kd values are greater than the laboratory desorption C-14 Kd values. We understand that additional groundwater sampling and testing is planned. The additional groundwater sampling and testing data will be used to further support site evaluation and risk-based decisions. Conclusions A main finding is the limited distribution of C-14 in soil, diminishing with depth, and that the observed C-14 groundwater concentrations are well below the MCL value (2,000 pCi/L), even though soil leaching and desorption to groundwater have been occurring for a relatively long time (> 30 years).
Technical Memorandum Fort Mims Drive | Maryland Heights, Missouri March 24, 2017 | Geotechnology Project No. J024002.03
4
C-14 concentrations observed in soil and groundwater samples from the site combined with the laboratory leaching and C-14 desorption analysis (Kd) indicate that, based on existing site data, the site groundwater concentrations will not reach risk-based levels for C-14 in drinking water. This conclusion is further supported by soil leaching/desorption being a primary rate limiting process for the soil to groundwater pathway. We recommend that selection of Kd values to be used as part of risk based decisions for the site consider the following:
Laboratory C-14 desorption analyses
Representative site specific soil and groundwater concentrations (e.g., 26.28/0.151)
Default conservative Kd values (e.g., 0.8 to 20) used to establish Preliminary Remediation Goals (PRGs)
In our opinion, the existing site data indicate that site specific Kd values could range from approximately 10 to >100.
ATTACHMENT 1
ANALYTICAL REPORTTestAmerica Laboratories, Inc.TestAmerica St. Louis13715 Rider Trail NorthEarth City, MO 63045Tel: (314)298-8566
TestAmerica Job ID: 160-19756-2Client Project/Site: MA-15-028
For:Decontamination Decommissioning and Envi345 North Avenue, 2nd FloorWakefield, Massachusetts 01880
Attn: Matt Norton
Authorized for release by:1/25/2017 3:32:49 PM
Elizabeth Hoerchler, Project Mgmt. Assistant(314)[email protected]
This report has been electronically signed and authorized by the signatory. Electronic signature isintended to be the legally binding equivalent of a traditionally handwritten signature.
Results relate only to the items tested and the sample(s) as received by the laboratory.
1
2
3
4
5
6
7
8
9
10
11
Table of Contents
Client: Decontamination Decommissioning and EnviProject/Site: MA-15-028
TestAmerica Job ID: 160-19756-2
Page 2 of 25TestAmerica St. Louis
1/25/2017
Cover Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Case Narrative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chain of Custody . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Receipt Checklists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Definitions/Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Method Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sample Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Client Sample Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
QC Sample Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
QC Association Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1
2
3
4
5
6
7
8
9
10
11
Case NarrativeClient: Decontamination Decommissioning and Envi TestAmerica Job ID: 160-19756-2Project/Site: MA-15-028
Job ID: 160-19756-2
Laboratory: TestAmerica St. Louis
Narrative
CASE NARRATIVE
Client: Decontamination Decommissioning and Envi
Project: MA-15-028
Report Number: 160-19756-2
With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control
limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.
TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses
performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmerica’s operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.
The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions
to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.
Calculations are performed before rounding to avoid round-off errors in calculated results.
All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.
All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a % solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and
disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.
This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.
RECEIPTThe samples were received on 10/31/2016; the samples arrived in good condition, properly preserved. The temperature of the coolers at
receipt was 18.0° C.
CARBON-14 BY LSC
Samples 049-N-01 (160-19756-1), 049-N-02 (160-19756-2), 049-E-01 (160-19756-3), 049-E-02 (160-19756-4), 049-S-01 (160-19756-5), 049-S-02 (160-19756-6), 049-W-01 (160-19756-7), 049-W-02 (160-19756-8), 061-N-01 (160-19756-9), 061-N-02 (160-19756-10),
061-E-01 (160-19756-11), 061-E-02 (160-19756-12), 061-S-01 (160-19756-13), 061-S-02 (160-19756-14), 061-W-01 (160-19756-15),
061-W-02 (160-19756-16), 051-N-01 (160-19756-17), 051-N-02 (160-19756-18), 051-E-01 (160-19756-19), 051-E-02 (160-19756-20), 051-S-01 (160-19756-21), 051-S-02 (160-19756-22), 051-W-01 (160-19756-23), 051-W-02 (160-19756-24), 047-E-01 (160-19756-25),
047-E-02 (160-19756-26), 047-S-01 (160-19756-27), 047-S-02 (160-19756-28), 047-W-01 (160-19756-29), 047-W-02 (160-19756-30),
047-N-02 (160-19756-31) and 047-N-02 (160-19756-32) were analyzed for Carbon-14 by LSC in accordance with EERF C-01. The samples were prepared on 12/20/2016 and 12/22/2016 and analyzed on 12/21/2016, 12/22/2016, 12/24/2016 and 12/25/2016.
Prep Batch: 160-284700
TestAmerica St. LouisPage 3 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Case NarrativeClient: Decontamination Decommissioning and Envi TestAmerica Job ID: 160-19756-2Project/Site: MA-15-028
Job ID: 160-19756-2 (Continued)
Laboratory: TestAmerica St. Louis (Continued)
The reporting limits associated with the carbon-14 samples have been increased by a factor of 20 due to a system limitation in TALS
associated with the DI leach preparation. 049-N-01 (160-19756-1), 049-N-02 (160-19756-2), 049-E-01 (160-19756-3), 049-E-02 (160-19756-4), 049-S-01 (160-19756-5), 049-S-02 (160-19756-6), 049-S-02 (160-19756-6[DU]), 049-S-02 (160-19756-6[MS]), 049-W-01
(160-19756-7), 049-W-02 (160-19756-8), 061-N-01 (160-19756-9), 061-N-01 (160-19756-9[DU]), 061-N-01 (160-19756-9[MS]), 061-N-02
(160-19756-10), 061-E-01 (160-19756-11), 061-E-02 (160-19756-12), 061-S-01 (160-19756-13), 061-S-02 (160-19756-14), 061-W-01 (160-19756-15) and 061-W-02 (160-19756-16) All samples are confirmed to meet our standard reporting limit of 5.00 pCi/g, and are
reported with this narrative.
Prep Batch: 160-285128
The following samples were run on the same apparatus instead of individual ones: 051-N-01 (160-19756-17) and 051-E-02 (160-19756-20). The samples do not physically touch the apparatus, but there is still possibility of cross contamination. Sample
19756-17 was run through the apparatus first. Since sample 20 is non-detect, there is no evidence of cross contamination, and the results are reported.
The reporting limits associated with the carbon-14 samples have been increased by a factor of 20 due to a system limitation in TALS associated with the DI leach preparation. 051-N-01 (160-19756-17), 051-N-02 (160-19756-18), 051-N-02 (160-19756-18[DU]), 051-N-02 (160-19756-18[MS]), 051-E-01 (160-19756-19), 051-E-02 (160-19756-20), 051-S-01 (160-19756-21), 051-S-02 (160-19756-22),
051-W-01 (160-19756-23), 051-W-02 (160-19756-24), 047-E-01 (160-19756-25), 047-E-02 (160-19756-26), 047-S-01 (160-19756-27), 047-S-02 (160-19756-28), 047-W-01 (160-19756-29), 047-W-02 (160-19756-30), 047-N-02 (160-19756-31) and 047-N-02 (160-19756-32) All samples are confirmed to meet our standard reporting limit of 5.00 pCi/g, and are reported with this narrative.
No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
TestAmerica St. LouisPage 4 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Page 5 of 25
1/25/2017
1234567891011
Page 6 of 25
1/25/2017
1234567891011
Page 7 of 25
1/25/2017
1234567891011
Page 8 of 25
1/25/2017
1234567891011
Page 9 of 25
1/25/2017
1234567891011
Login Sample Receipt Checklist
Client: Decontamination Decommissioning and Envi Job Number: 160-19756-2
Login Number: 19756
Question Answer Comment
Creator: Daniels, Brian J
List Source: TestAmerica St. Louis
List Number: 1
TrueRadioactivity wasn't checked or is </= background as measured by a survey meter.
N/AThe cooler's custody seal, if present, is intact.
N/ASample custody seals, if present, are intact.
TrueThe cooler or samples do not appear to have been compromised or tampered with.
FalseSamples were received on ice.
TrueCooler Temperature is acceptable.
TrueCooler Temperature is recorded.
TrueCOC is present.
TrueCOC is filled out in ink and legible.
TrueCOC is filled out with all pertinent information.
TrueIs the Field Sampler's name present on COC?
TrueThere are no discrepancies between the containers received and the COC.
TrueSamples are received within Holding Time (excluding tests with immediate HTs)
TrueSample containers have legible labels.
TrueContainers are not broken or leaking.
TrueSample collection date/times are provided.
TrueAppropriate sample containers are used.
TrueSample bottles are completely filled.
TrueSample Preservation Verified.
TrueThere is sufficient vol. for all requested analyses, incl. any requested MS/MSDs
N/AContainers requiring zero headspace have no headspace or bubble is <6mm (1/4").
TrueMultiphasic samples are not present.
TrueSamples do not require splitting or compositing.
N/AResidual Chlorine Checked.
TestAmerica St. LouisPage 10 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Definitions/GlossaryTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Qualifiers
Rad
Qualifier Description
U Result is less than the sample detection limit.
Qualifier
Glossary
These commonly used abbreviations may or may not be present in this report.
¤ Listed under the "D" column to designate that the result is reported on a dry weight basis
Abbreviation
%R Percent Recovery
CFL Contains Free Liquid
CNF Contains no Free Liquid
DER Duplicate error ratio (normalized absolute difference)
Dil Fac Dilution Factor
DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample
DLC Decision level concentration
MDA Minimum detectable activity
EDL Estimated Detection Limit
MDC Minimum detectable concentration
MDL Method Detection Limit
ML Minimum Level (Dioxin)
NC Not Calculated
ND Not detected at the reporting limit (or MDL or EDL if shown)
PQL Practical Quantitation Limit
QC Quality Control
RER Relative error ratio
RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points
TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
TestAmerica St. Louis
Page 11 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Method SummaryTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method Method Description LaboratoryProtocol
EERFC-01-1 Carbon-14 (EERF C-01-1) TAL SL
Protocol References:
EERF = EERF
Laboratory References:
TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566
TestAmerica St. Louis
Page 12 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Sample SummaryTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID Client Sample ID ReceivedCollectedMatrix
160-19756-1 049-N-01 Solid 10/25/16 10:34 10/31/16 09:40
160-19756-2 049-N-02 Solid 10/25/16 13:43 10/31/16 09:40
160-19756-3 049-E-01 Solid 10/25/16 14:10 10/31/16 09:40
160-19756-4 049-E-02 Solid 10/25/16 14:30 10/31/16 09:40
160-19756-5 049-S-01 Solid 10/25/16 15:16 10/31/16 09:40
160-19756-6 049-S-02 Solid 10/25/16 15:20 10/31/16 09:40
160-19756-7 049-W-01 Solid 10/25/16 15:35 10/31/16 09:40
160-19756-8 049-W-02 Solid 10/25/16 15:39 10/31/16 09:40
160-19756-9 061-N-01 Solid 10/25/16 16:16 10/31/16 09:40
160-19756-10 061-N-02 Solid 10/25/16 16:30 10/31/16 09:40
160-19756-11 061-E-01 Solid 10/26/16 08:48 10/31/16 09:40
160-19756-12 061-E-02 Solid 10/26/16 08:42 10/31/16 09:40
160-19756-13 061-S-01 Solid 10/26/16 08:51 10/31/16 09:40
160-19756-14 061-S-02 Solid 10/26/16 09:02 10/31/16 09:40
160-19756-15 061-W-01 Solid 10/26/16 09:06 10/31/16 09:40
160-19756-16 061-W-02 Solid 10/26/16 09:09 10/31/16 09:40
160-19756-17 051-N-01 Solid 10/26/16 10:20 10/31/16 09:40
160-19756-18 051-N-02 Solid 10/26/16 10:23 10/31/16 09:40
160-19756-19 051-E-01 Solid 10/26/16 12:58 10/31/16 09:40
160-19756-20 051-E-02 Solid 10/26/16 13:01 10/31/16 09:40
160-19756-21 051-S-01 Solid 10/26/16 10:50 10/31/16 09:40
160-19756-22 051-S-02 Solid 10/26/16 10:58 10/31/16 09:40
160-19756-23 051-W-01 Solid 10/26/16 11:05 10/31/16 09:40
160-19756-24 051-W-02 Solid 10/26/16 11:09 10/31/16 09:40
160-19756-25 047-E-01 Solid 10/26/16 12:58 10/31/16 09:40
160-19756-26 047-E-02 Solid 10/26/16 13:01 10/31/16 09:40
160-19756-27 047-S-01 Solid 10/26/16 13:09 10/31/16 09:40
160-19756-28 047-S-02 Solid 10/26/16 13:16 10/31/16 09:40
160-19756-29 047-W-01 Solid 10/26/16 13:23 10/31/16 09:40
160-19756-30 047-W-02 Solid 10/26/16 13:26 10/31/16 09:40
160-19756-31 047-N-02 Solid 10/26/16 13:31 10/31/16 09:40
160-19756-32 047-N-02 Solid 10/26/16 13:35 10/31/16 09:40
TestAmerica St. Louis
Page 13 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-1Client Sample ID: 049-N-01Matrix: SolidDate Collected: 10/25/16 10:34
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.333 U
(2σ+/-)
0.451
(2σ+/-)
112/21/16 19:4911/09/16 09:40pCi/g0.7404.50
RL MDC
0.449
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-2Client Sample ID: 049-N-02Matrix: SolidDate Collected: 10/25/16 13:43
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.196 U
(2σ+/-)
0.461
(2σ+/-)
112/21/16 20:5511/09/16 09:40pCi/g0.7704.63
RL MDC
0.461
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-3Client Sample ID: 049-E-01Matrix: SolidDate Collected: 10/25/16 14:10
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.211 U
(2σ+/-)
0.390
(2σ+/-)
112/21/16 22:0211/09/16 09:40pCi/g0.6483.91
RL MDC
0.389
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-4Client Sample ID: 049-E-02Matrix: SolidDate Collected: 10/25/16 14:30
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.454 U
(2σ+/-)
0.457
(2σ+/-)
112/21/16 23:0811/09/16 09:40pCi/g0.7424.46
RL MDC
0.454
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-5Client Sample ID: 049-S-01Matrix: SolidDate Collected: 10/25/16 15:16
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.178 U
(2σ+/-)
0.436
(2σ+/-)
112/22/16 00:1411/09/16 09:40pCi/g0.7294.39
RL MDC
0.436
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 14 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-6Client Sample ID: 049-S-02Matrix: SolidDate Collected: 10/25/16 15:20
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.387 U
(2σ+/-)
0.449
(2σ+/-)
112/22/16 01:2011/09/16 09:40pCi/g0.7354.42
RL MDC
0.447
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-7Client Sample ID: 049-W-01Matrix: SolidDate Collected: 10/25/16 15:35
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.274 U
(2σ+/-)
0.488
(2σ+/-)
112/22/16 04:3911/09/16 09:40pCi/g0.8094.90
RL MDC
0.487
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-8Client Sample ID: 049-W-02Matrix: SolidDate Collected: 10/25/16 15:39
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 -0.135 U
(2σ+/-)
0.483
(2σ+/-)
112/22/16 05:4511/09/16 09:40pCi/g0.8285.00
RL MDC
0.483
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-9Client Sample ID: 061-N-01Matrix: SolidDate Collected: 10/25/16 16:16
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.800
(2σ+/-)
0.495
(2σ+/-)
112/22/16 06:5211/09/16 09:40pCi/g0.7794.67
RL MDC
0.488
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-10Client Sample ID: 061-N-02Matrix: SolidDate Collected: 10/25/16 16:30
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 2.11
(2σ+/-)
0.593
(2σ+/-)
112/22/16 10:1011/09/16 09:40pCi/g0.8014.85
RL MDC
0.547
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 15 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-11Client Sample ID: 061-E-01Matrix: SolidDate Collected: 10/26/16 08:48
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.934
(2σ+/-)
0.494
(2σ+/-)
112/22/16 11:1711/09/16 09:40pCi/g0.7624.63
RL MDC
0.484
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-12Client Sample ID: 061-E-02Matrix: SolidDate Collected: 10/26/16 08:42
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.67
(2σ+/-)
0.567
(2σ+/-)
112/22/16 12:2311/09/16 09:40pCi/g0.8104.85
RL MDC
0.537
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-13Client Sample ID: 061-S-01Matrix: SolidDate Collected: 10/26/16 08:51
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.844
(2σ+/-)
0.516
(2σ+/-)
112/22/16 13:2911/09/16 09:40pCi/g0.8104.85
RL MDC
0.508
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-14Client Sample ID: 061-S-02Matrix: SolidDate Collected: 10/26/16 09:02
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.446 U
(2σ+/-)
0.485
(2σ+/-)
112/22/16 14:3511/09/16 09:40pCi/g0.7924.76
RL MDC
0.483
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-15Client Sample ID: 061-W-01Matrix: SolidDate Collected: 10/26/16 09:06
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.722
(2σ+/-)
0.422
(2σ+/-)
112/22/16 15:4211/09/16 09:40pCi/g0.6593.97
RL MDC
0.415
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 16 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-16Client Sample ID: 061-W-02Matrix: SolidDate Collected: 10/26/16 09:09
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.85
(2σ+/-)
0.578
(2σ+/-)
112/22/16 16:4811/09/16 09:40pCi/g0.8104.85
RL MDC
0.543
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-17Client Sample ID: 051-N-01Matrix: SolidDate Collected: 10/26/16 10:20
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.05
(2σ+/-)
0.465
(2σ+/-)
112/24/16 18:2611/09/16 09:40pCi/g0.6994.72
RL MDC
0.451
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-18Client Sample ID: 051-N-02Matrix: SolidDate Collected: 10/26/16 10:23
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.364 U
(2σ+/-)
0.349
(2σ+/-)
112/24/16 19:3211/09/16 09:40pCi/g0.5673.85
RL MDC
0.347
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-19Client Sample ID: 051-E-01Matrix: SolidDate Collected: 10/26/16 12:58
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.502 U
(2σ+/-)
0.442
(2σ+/-)
112/24/16 22:5111/09/16 09:40pCi/g0.7164.76
RL MDC
0.438
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-20Client Sample ID: 051-E-02Matrix: SolidDate Collected: 10/26/16 13:01
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.459 U
(2σ+/-)
0.438
(2σ+/-)
112/24/16 23:5711/09/16 09:40pCi/g0.7134.76
RL MDC
0.435
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 17 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-21Client Sample ID: 051-S-01Matrix: SolidDate Collected: 10/26/16 10:50
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.468 U
(2σ+/-)
0.457
(2σ+/-)
112/25/16 01:0311/09/16 09:40pCi/g0.7454.95
RL MDC
0.454
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-22Client Sample ID: 051-S-02Matrix: SolidDate Collected: 10/26/16 10:58
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.593 U
(2σ+/-)
0.462
(2σ+/-)
112/25/16 02:1011/09/16 09:40pCi/g0.7424.95
RL MDC
0.457
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-23Client Sample ID: 051-W-01Matrix: SolidDate Collected: 10/26/16 11:05
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.374 U
(2σ+/-)
0.429
(2σ+/-)
112/25/16 03:1611/09/16 09:40pCi/g0.7044.72
RL MDC
0.427
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-24Client Sample ID: 051-W-02Matrix: SolidDate Collected: 10/26/16 11:09
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.329 U
(2σ+/-)
0.370
(2σ+/-)
112/25/16 04:2211/09/16 09:40pCi/g0.6074.10
RL MDC
0.369
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-25Client Sample ID: 047-E-01Matrix: SolidDate Collected: 10/26/16 12:58
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.12
(2σ+/-)
0.447
(2σ+/-)
112/25/16 05:2911/09/16 09:40pCi/g0.6584.46
RL MDC
0.431
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 18 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-26Client Sample ID: 047-E-02Matrix: SolidDate Collected: 10/26/16 13:01
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.807
(2σ+/-)
0.458
(2σ+/-)
112/25/16 06:3511/09/16 09:40pCi/g0.7144.76
RL MDC
0.450
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-27Client Sample ID: 047-S-01Matrix: SolidDate Collected: 10/26/16 13:09
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.835
(2σ+/-)
0.466
(2σ+/-)
112/25/16 07:4111/09/16 09:40pCi/g0.7244.85
RL MDC
0.457
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-28Client Sample ID: 047-S-02Matrix: SolidDate Collected: 10/26/16 13:16
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.338 U
(2σ+/-)
0.380
(2σ+/-)
112/25/16 08:4711/09/16 09:40pCi/g0.6234.17
RL MDC
0.378
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-29Client Sample ID: 047-W-01Matrix: SolidDate Collected: 10/26/16 13:23
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.52
(2σ+/-)
0.519
(2σ+/-)
112/25/16 09:5411/09/16 09:40pCi/g0.7374.24
RL MDC
0.493
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-30Client Sample ID: 047-W-02Matrix: SolidDate Collected: 10/26/16 13:26
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.615 U
(2σ+/-)
0.440
(2σ+/-)
112/25/16 11:0011/09/16 09:40pCi/g0.7034.67
RL MDC
0.435
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 19 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-31Client Sample ID: 047-N-02Matrix: SolidDate Collected: 10/26/16 13:31
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.12
(2σ+/-)
0.479
(2σ+/-)
112/25/16 12:0611/09/16 09:40pCi/g0.7174.81
RL MDC
0.464
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-32Client Sample ID: 047-N-02Matrix: SolidDate Collected: 10/26/16 13:35
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.27
(2σ+/-)
0.486
(2σ+/-)
112/25/16 13:1211/09/16 09:46pCi/g0.7104.76
RL MDC
0.466
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 20 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Client Sample ID: 049-S-02Lab Sample ID: 160-19756-6 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285296 Prep Batch: 278422
Carbon-14
Analyte
128-299978.9779.60.387 U 8.70 4.72 0.782
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 061-N-01Lab Sample ID: 160-19756-9 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285296 Prep Batch: 278422
Carbon-14
Analyte
128-2910178.8677.40.800 8.69 4.59 0.764
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 051-N-02Lab Sample ID: 160-19756-18 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285457 Prep Batch: 278422
Carbon-14
Analyte
128-299672.1875.40.364 U 7.96 4.46 0.658
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 049-S-02Lab Sample ID: 160-19756-6 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285296 Prep Batch: 278422
Carbon-14
Analyte
10.48U-0.050990.387 U 0.459 4.72 0.783
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Client Sample ID: 061-N-01Lab Sample ID: 160-19756-9 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285296 Prep Batch: 278422
Carbon-14
Analyte
10.020.82070.800 0.453 4.24 0.704
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Client Sample ID: 051-N-02Lab Sample ID: 160-19756-18 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285457 Prep Batch: 278422
Carbon-14
Analyte
10.01U0.37460.364 U 0.448 4.95 0.738
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
TestAmerica St. Louis
Page 21 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Sample ResultsTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method: C-01-1 - Carbon-14 (EERF C-01-1) (Continued)
Client Sample ID: Method BlankLab Sample ID: MB 160-284700/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285296 Prep Batch: 284700
Carbon-14
Analyte
U 112/21/16 17:3612/20/16 10:03pCi/g0.829
MDC
5.00
RL
0.4920.492
(2σ+/-) (2σ+/-)
MB
0.08559
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-284700/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285296 Prep Batch: 284700
Carbon-14
Analyte
124-679681.0084.4 8.93 5.00 0.825
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
Client Sample ID: Method BlankLab Sample ID: MB 160-285128/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285457 Prep Batch: 285128
Carbon-14
Analyte
U 112/24/16 16:1312/22/16 12:45pCi/g0.728
MDC
5.00
RL
0.4510.448
(2σ+/-) (2σ+/-)
MB
0.4820
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-285128/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285457 Prep Batch: 285128
Carbon-14
Analyte
124-679579.9484.4 8.81 5.00 0.735
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
TestAmerica St. Louis
Page 22 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Association SummaryTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Rad
Prep Batch: 278422
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid DILeach_Prep_R
d
160-19756-1 049-N-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-2 049-N-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-3 049-E-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-4 049-E-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-5 049-S-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-6 049-S-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-7 049-W-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-8 049-W-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-9 061-N-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-10 061-N-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-11 061-E-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-12 061-E-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-13 061-S-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-14 061-S-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-15 061-W-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-16 061-W-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-17 051-N-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-18 051-N-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-19 051-E-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-20 051-E-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-21 051-S-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-22 051-S-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-23 051-W-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-24 051-W-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-25 047-E-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-26 047-E-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-27 047-S-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-28 047-S-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-29 047-W-01 Total/NA
TestAmerica St. Louis
Page 23 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Association SummaryTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Rad (Continued)
Prep Batch: 278422 (Continued)
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid DILeach_Prep_R
d
160-19756-30 047-W-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-31 047-N-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-32 047-N-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-6 MS 049-S-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-9 MS 061-N-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-18 MS 051-N-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-6 DU 049-S-02 Total/NA
Solid DILeach_Prep_R
d
160-19756-9 DU 061-N-01 Total/NA
Solid DILeach_Prep_R
d
160-19756-18 DU 051-N-02 Total/NA
Prep Batch: 284700
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp 278422160-19756-1 049-N-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-2 049-N-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-3 049-E-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-4 049-E-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-5 049-S-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-6 049-S-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-7 049-W-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-8 049-W-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-9 061-N-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-10 061-N-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-11 061-E-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-12 061-E-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-13 061-S-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-14 061-S-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-15 061-W-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-16 061-W-02 Total/NA
Solid LSC_Dist_SuspMB 160-284700/1-A Method Blank Total/NA
Solid LSC_Dist_SuspLCS 160-284700/2-A Lab Control Sample Total/NA
Solid LSC_Dist_Susp 278422160-19756-6 MS 049-S-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-9 MS 061-N-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-6 DU 049-S-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-9 DU 061-N-01 Total/NA
Prep Batch: 285128
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp 278422160-19756-17 051-N-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-18 051-N-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-19 051-E-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-20 051-E-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-21 051-S-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-22 051-S-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-23 051-W-01 Total/NA
TestAmerica St. Louis
Page 24 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Association SummaryTestAmerica Job ID: 160-19756-2Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Rad (Continued)
Prep Batch: 285128 (Continued)
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp 278422160-19756-24 051-W-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-25 047-E-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-26 047-E-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-27 047-S-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-28 047-S-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-29 047-W-01 Total/NA
Solid LSC_Dist_Susp 278422160-19756-30 047-W-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-31 047-N-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-32 047-N-02 Total/NA
Solid LSC_Dist_SuspMB 160-285128/1-A Method Blank Total/NA
Solid LSC_Dist_SuspLCS 160-285128/2-A Lab Control Sample Total/NA
Solid LSC_Dist_Susp 278422160-19756-18 MS 051-N-02 Total/NA
Solid LSC_Dist_Susp 278422160-19756-18 DU 051-N-02 Total/NA
TestAmerica St. Louis
Page 25 of 25 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
ANALYTICAL REPORTTestAmerica Laboratories, Inc.TestAmerica St. Louis13715 Rider Trail NorthEarth City, MO 63045Tel: (314)298-8566
TestAmerica Job ID: 160-19756-1Client Project/Site: MA-15-028Revision: 1
For:Decontamination Decommissioning and Envi345 North Avenue, 2nd FloorWakefield, Massachusetts 01880
Attn: Matt Norton
Authorized for release by:1/25/2017 3:30:42 PM
Elizabeth Hoerchler, Project Mgmt. Assistant(314)[email protected]
This report has been electronically signed and authorized by the signatory. Electronic signature isintended to be the legally binding equivalent of a traditionally handwritten signature.
Results relate only to the items tested and the sample(s) as received by the laboratory.
1
2
3
4
5
6
7
8
9
10
11
Table of Contents
Client: Decontamination Decommissioning and EnviProject/Site: MA-15-028
TestAmerica Job ID: 160-19756-1
Page 2 of 26TestAmerica St. Louis
1/25/2017
Cover Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Case Narrative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chain of Custody . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Receipt Checklists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Definitions/Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Method Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sample Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Client Sample Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
QC Sample Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
QC Association Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1
2
3
4
5
6
7
8
9
10
11
Case NarrativeClient: Decontamination Decommissioning and Envi TestAmerica Job ID: 160-19756-1Project/Site: MA-15-028
Job ID: 160-19756-1
Laboratory: TestAmerica St. Louis
Narrative
CASE NARRATIVE
Client: Decontamination Decommissioning and Envi
Project: MA-15-028
Report Number: 160-19756-1
With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control
limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.
TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses
performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmerica’s operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.
The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions
to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.
Calculations are performed before rounding to avoid round-off errors in calculated results.
All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.
All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a % solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and
disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.
This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.
RECEIPTThe samples were received on 10/31/2016; the samples arrived in good condition, properly preserved and on ice. The temperature of the
coolers at receipt was 18.0° C.
PERCENT SOLIDS
Samples 030-106-02 (160-19756-34), 030-107-02 (160-19756-36), 030-108-02 (160-19756-38) and 030-109-02 (160-19756-40) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 11/02/2016.
No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
TRITIUM
Samples 030-106-02 (160-19756-34), 030-107-02 (160-19756-36), 030-108-02 (160-19756-38) and 030-109-02 (160-19756-40) were analyzed for Tritium in accordance with EPA Method 906.0. The samples were prepared and analyzed on 11/25/2016.
Prep Batch: 160-280941
TestAmerica St. LouisPage 3 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Case NarrativeClient: Decontamination Decommissioning and Envi TestAmerica Job ID: 160-19756-1Project/Site: MA-15-028
Job ID: 160-19756-1 (Continued)
Laboratory: TestAmerica St. Louis (Continued)
The matrix spike (MS) has a spike recovery (148%) above the QC limit (78-122%). The LCS (laboratory control sample) has an acceptable
spike recovery demonstrating acceptable sample preparation and instrument performance. The data have been qualified and reported. 030-106-02 (160-19756-34), 030-106-02 (160-19756-34[DU]), 030-106-02 (160-19756-34[MS]), 030-107-02 (160-19756-36), 030-108-02
(160-19756-38), 030-109-02 (160-19756-40), (LCS 160-280941/2-A) and (MB 160-280941/1-A).
No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
CARBON-14 BY LSC
Samples 049-N-01 (160-19756-1), 049-N-02 (160-19756-2), 049-E-01 (160-19756-3), 049-E-02 (160-19756-4), 049-S-01 (160-19756-5),
049-S-02 (160-19756-6), 049-W-01 (160-19756-7), 049-W-02 (160-19756-8), 061-N-01 (160-19756-9), 061-N-02 (160-19756-10), 061-E-01 (160-19756-11), 061-E-02 (160-19756-12), 061-S-01 (160-19756-13), 061-S-02 (160-19756-14), 061-W-01 (160-19756-15),
061-W-02 (160-19756-16), 051-N-01 (160-19756-17), 051-N-02 (160-19756-18), 051-E-01 (160-19756-19), 051-E-02 (160-19756-20), 051-S-01 (160-19756-21), 051-S-02 (160-19756-22), 051-W-01 (160-19756-23), 051-W-02 (160-19756-24), 047-E-01 (160-19756-25),
047-E-02 (160-19756-26), 047-S-01 (160-19756-27), 047-S-02 (160-19756-28), 047-W-01 (160-19756-29), 047-W-02 (160-19756-30),
047-N-02 (160-19756-31), 047-N-02 (160-19756-32), 030-106-01 (160-19756-33), 030-107-01 (160-19756-35), 030-108-01 (160-19756-37) and 030-109-01 (160-19756-39) were analyzed for Carbon-14 by LSC in accordance with EERF C-01. The samples were prepared on 12/14/2016 and 12/27/2016 and analyzed on 12/16/2016, 12/17/2016, 12/19/2016, 12/29/2016 and 12/30/2016.
Prep Batch: 160-283916The following samples could not be thoroughly homogenized before sub-sampling was performed due to sample matrix: 049-N-01 (160-19756-1), 049-N-02 (160-19756-2), 049-E-01 (160-19756-3), 049-E-02 (160-19756-4), 049-S-01 (160-19756-5), 049-S-02 (160-19756-6), 049-S-02 (160-19756-6[DU]), 049-S-02 (160-19756-6[MS]), 049-W-01 (160-19756-7), 049-W-02 (160-19756-8), 061-N-01
(160-19756-9), 061-N-01 (160-19756-9[DU]), 061-N-01 (160-19756-9[MS]), 061-N-02 (160-19756-10), 061-E-01 (160-19756-11), 061-E-02 (160-19756-12), 061-S-01 (160-19756-13), 061-S-02 (160-19756-14), 061-W-01 (160-19756-15), 061-W-02 (160-19756-16), 051-N-01 (160-19756-17) and 051-E-01 (160-19756-19). The samples were prepped as received.
The sample duplicate precision (RER/RPD) associated with the following samples is outside control limit of 1.0/40%. (160-19756-A-6-E
DU: RER: 2.82 and RPD: 69%) (160-19756-A-9-E DU: RER: 4.95 and RPD: 114%). 049-N-01 (160-19756-1), 049-N-02 (160-19756-2), 049-E-01 (160-19756-3), 049-E-02 (160-19756-4), 049-S-01 (160-19756-5), 049-S-02 (160-19756-6), 049-S-02 (160-19756-6[DU]), 049-S-02 (160-19756-6[MS]), 049-W-01 (160-19756-7), 049-W-02 (160-19756-8), 061-N-01 (160-19756-9), 061-N-01 (160-19756-9[DU]), 061-N-01 (160-19756-9[MS]), 061-N-02 (160-19756-10), 061-E-01 (160-19756-11), 061-E-02 (160-19756-12), 061-S-01 (160-19756-13), 061-S-02 (160-19756-14), 061-W-01 (160-19756-15), 061-W-02 (160-19756-16), 051-N-01 (160-19756-17), 051-E-01 (160-19756-19),
(LCS 160-283916/2-A) and (MB 160-283916/1-A) The samples are non-homogenous as they were analyzed as received. The data have been qualified and reported.
No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
TestAmerica St. LouisPage 4 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Page 5 of 26
1/25/2017
1234567891011
Page 6 of 26
1/25/2017
1234567891011
Page 7 of 26
1/25/2017
1234567891011
Page 8 of 26
1/25/2017
1234567891011
Page 9 of 26
1/25/2017
1234567891011
Login Sample Receipt Checklist
Client: Decontamination Decommissioning and Envi Job Number: 160-19756-1
Login Number: 19756
Question Answer Comment
Creator: Daniels, Brian J
List Source: TestAmerica St. Louis
List Number: 1
TrueRadioactivity wasn't checked or is </= background as measured by a survey meter.
N/AThe cooler's custody seal, if present, is intact.
N/ASample custody seals, if present, are intact.
TrueThe cooler or samples do not appear to have been compromised or tampered with.
FalseSamples were received on ice.
TrueCooler Temperature is acceptable.
TrueCooler Temperature is recorded.
TrueCOC is present.
TrueCOC is filled out in ink and legible.
TrueCOC is filled out with all pertinent information.
TrueIs the Field Sampler's name present on COC?
TrueThere are no discrepancies between the containers received and the COC.
TrueSamples are received within Holding Time (excluding tests with immediate HTs)
TrueSample containers have legible labels.
TrueContainers are not broken or leaking.
TrueSample collection date/times are provided.
TrueAppropriate sample containers are used.
TrueSample bottles are completely filled.
TrueSample Preservation Verified.
TrueThere is sufficient vol. for all requested analyses, incl. any requested MS/MSDs
N/AContainers requiring zero headspace have no headspace or bubble is <6mm (1/4").
TrueMultiphasic samples are not present.
TrueSamples do not require splitting or compositing.
N/AResidual Chlorine Checked.
TestAmerica St. LouisPage 10 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Definitions/GlossaryTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Qualifiers
Rad
Qualifier Description
U Result is less than the sample detection limit.
Qualifier
F1 MS and/or MSD Recovery is outside acceptance limits.
F Duplicate RPD exceeds the control limit
Glossary
These commonly used abbreviations may or may not be present in this report.
¤ Listed under the "D" column to designate that the result is reported on a dry weight basis
Abbreviation
%R Percent Recovery
CFL Contains Free Liquid
CNF Contains no Free Liquid
DER Duplicate error ratio (normalized absolute difference)
Dil Fac Dilution Factor
DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample
DLC Decision level concentration
MDA Minimum detectable activity
EDL Estimated Detection Limit
MDC Minimum detectable concentration
MDL Method Detection Limit
ML Minimum Level (Dioxin)
NC Not Calculated
ND Not detected at the reporting limit (or MDL or EDL if shown)
PQL Practical Quantitation Limit
QC Quality Control
RER Relative error ratio
RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points
TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
TestAmerica St. Louis
Page 11 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Method SummaryTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method Method Description LaboratoryProtocol
EPAMoisture Percent Moisture TAL SL
EPA906.0 Tritium, Total (LSC) TAL SL
EERFC-01-1 Carbon-14 (EERF C-01-1) TAL SL
Protocol References:
EERF = EERF
EPA = US Environmental Protection Agency
Laboratory References:
TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566
TestAmerica St. Louis
Page 12 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Sample SummaryTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID Client Sample ID ReceivedCollectedMatrix
160-19756-1 049-N-01 Solid 10/25/16 10:34 10/31/16 09:40
160-19756-2 049-N-02 Solid 10/25/16 13:43 10/31/16 09:40
160-19756-3 049-E-01 Solid 10/25/16 14:10 10/31/16 09:40
160-19756-4 049-E-02 Solid 10/25/16 14:30 10/31/16 09:40
160-19756-5 049-S-01 Solid 10/25/16 15:16 10/31/16 09:40
160-19756-6 049-S-02 Solid 10/25/16 15:20 10/31/16 09:40
160-19756-7 049-W-01 Solid 10/25/16 15:35 10/31/16 09:40
160-19756-8 049-W-02 Solid 10/25/16 15:39 10/31/16 09:40
160-19756-9 061-N-01 Solid 10/25/16 16:16 10/31/16 09:40
160-19756-10 061-N-02 Solid 10/25/16 16:30 10/31/16 09:40
160-19756-11 061-E-01 Solid 10/26/16 08:48 10/31/16 09:40
160-19756-12 061-E-02 Solid 10/26/16 08:42 10/31/16 09:40
160-19756-13 061-S-01 Solid 10/26/16 08:51 10/31/16 09:40
160-19756-14 061-S-02 Solid 10/26/16 09:02 10/31/16 09:40
160-19756-15 061-W-01 Solid 10/26/16 09:06 10/31/16 09:40
160-19756-16 061-W-02 Solid 10/26/16 09:09 10/31/16 09:40
160-19756-17 051-N-01 Solid 10/26/16 10:20 10/31/16 09:40
160-19756-18 051-N-02 Solid 10/26/16 10:23 10/31/16 09:40
160-19756-19 051-E-01 Solid 10/26/16 12:58 10/31/16 09:40
160-19756-20 051-E-02 Solid 10/26/16 13:01 10/31/16 09:40
160-19756-21 051-S-01 Solid 10/26/16 10:50 10/31/16 09:40
160-19756-22 051-S-02 Solid 10/26/16 10:58 10/31/16 09:40
160-19756-23 051-W-01 Solid 10/26/16 11:05 10/31/16 09:40
160-19756-24 051-W-02 Solid 10/26/16 11:09 10/31/16 09:40
160-19756-25 047-E-01 Solid 10/26/16 12:58 10/31/16 09:40
160-19756-26 047-E-02 Solid 10/26/16 13:01 10/31/16 09:40
160-19756-27 047-S-01 Solid 10/26/16 13:09 10/31/16 09:40
160-19756-28 047-S-02 Solid 10/26/16 13:16 10/31/16 09:40
160-19756-29 047-W-01 Solid 10/26/16 13:23 10/31/16 09:40
160-19756-30 047-W-02 Solid 10/26/16 13:26 10/31/16 09:40
160-19756-31 047-N-02 Solid 10/26/16 13:31 10/31/16 09:40
160-19756-32 047-N-02 Solid 10/26/16 13:35 10/31/16 09:40
160-19756-33 030-106-01 Solid 10/27/16 08:06 10/31/16 09:40
160-19756-34 030-106-02 Solid 10/27/16 08:06 10/31/16 09:40
160-19756-35 030-107-01 Solid 10/27/16 08:26 10/31/16 09:40
160-19756-36 030-107-02 Solid 10/27/16 08:26 10/31/16 09:40
160-19756-37 030-108-01 Solid 10/27/16 08:35 10/31/16 09:40
160-19756-38 030-108-02 Solid 10/27/16 08:35 10/31/16 09:40
160-19756-39 030-109-01 Solid 10/27/16 08:41 10/31/16 09:40
160-19756-40 030-109-02 Solid 10/27/16 08:41 10/31/16 09:40
TestAmerica St. Louis
Page 13 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-1Client Sample ID: 049-N-01Matrix: SolidDate Collected: 10/25/16 10:34
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 6.05
(2σ+/-)
0.929
(2σ+/-)
112/16/16 13:1412/14/16 13:08pCi/g0.7971.00
RL MDC
0.661
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-2Client Sample ID: 049-N-02Matrix: SolidDate Collected: 10/25/16 13:43
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 6.11
(2σ+/-)
0.958
(2σ+/-)
112/16/16 14:2012/14/16 13:08pCi/g0.8531.00
RL MDC
0.695
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-3Client Sample ID: 049-E-01Matrix: SolidDate Collected: 10/25/16 14:10
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 18.3
(2σ+/-)
2.19
(2σ+/-)
112/16/16 15:2712/14/16 13:08pCi/g0.8311.00
RL MDC
0.962
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-4Client Sample ID: 049-E-02Matrix: SolidDate Collected: 10/25/16 14:30
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 2.83
(2σ+/-)
0.668
(2σ+/-)
112/16/16 16:3312/14/16 13:08pCi/g0.8501.00
RL MDC
0.594
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-5Client Sample ID: 049-S-01Matrix: SolidDate Collected: 10/25/16 15:16
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 28.9
(2σ+/-)
3.32
(2σ+/-)
112/16/16 17:3912/14/16 13:08pCi/g0.8101.00
RL MDC
1.13
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 14 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-6Client Sample ID: 049-S-02Matrix: SolidDate Collected: 10/25/16 15:20
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 10.6
(2σ+/-)
1.39
(2σ+/-)
112/19/16 11:3112/14/16 13:08pCi/g0.8171.00
RL MDC
0.799
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-7Client Sample ID: 049-W-01Matrix: SolidDate Collected: 10/25/16 15:35
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 11.8
(2σ+/-)
1.51
(2σ+/-)
112/16/16 23:1112/14/16 13:08pCi/g0.8111.00
RL MDC
0.812
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-8Client Sample ID: 049-W-02Matrix: SolidDate Collected: 10/25/16 15:39
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 2.09
(2σ+/-)
0.590
(2σ+/-)
112/17/16 00:1712/14/16 13:08pCi/g0.8101.00
RL MDC
0.545
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-9Client Sample ID: 061-N-01Matrix: SolidDate Collected: 10/25/16 16:16
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 47.6
(2σ+/-)
5.35
(2σ+/-)
112/19/16 14:4912/14/16 13:08pCi/g0.8321.00
RL MDC
1.45
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-10Client Sample ID: 061-N-02Matrix: SolidDate Collected: 10/25/16 16:30
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 54.3
(2σ+/-)
6.07
(2σ+/-)
112/17/16 04:4212/14/16 13:08pCi/g0.9021.00
RL MDC
1.58
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 15 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-11Client Sample ID: 061-E-01Matrix: SolidDate Collected: 10/26/16 08:48
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 69.3
(2σ+/-)
7.67
(2σ+/-)
112/17/16 05:4812/14/16 13:08pCi/g0.8031.00
RL MDC
1.66
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-12Client Sample ID: 061-E-02Matrix: SolidDate Collected: 10/26/16 08:42
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 56.5
(2σ+/-)
6.29
(2σ+/-)
112/17/16 06:5412/14/16 13:08pCi/g0.8161.00
RL MDC
1.53
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-13Client Sample ID: 061-S-01Matrix: SolidDate Collected: 10/26/16 08:51
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 12.2
(2σ+/-)
1.56
(2σ+/-)
112/17/16 08:0112/14/16 13:08pCi/g0.8391.00
RL MDC
0.840
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-14Client Sample ID: 061-S-02Matrix: SolidDate Collected: 10/26/16 09:02
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 5.17
(2σ+/-)
0.869
(2σ+/-)
112/17/16 09:0712/14/16 13:08pCi/g0.8501.00
RL MDC
0.666
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-15Client Sample ID: 061-W-01Matrix: SolidDate Collected: 10/26/16 09:06
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 31.4
(2σ+/-)
3.59
(2σ+/-)
112/17/16 10:1312/14/16 13:08pCi/g0.8361.00
RL MDC
1.19
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 16 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-16Client Sample ID: 061-W-02Matrix: SolidDate Collected: 10/26/16 09:09
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 45.7
(2σ+/-)
5.14
(2σ+/-)
112/17/16 11:1912/14/16 13:08pCi/g0.8631.00
RL MDC
1.43
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-17Client Sample ID: 051-N-01Matrix: SolidDate Collected: 10/26/16 10:20
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 5.21
(2σ+/-)
0.872
(2σ+/-)
112/17/16 12:2612/14/16 13:08pCi/g0.8501.00
RL MDC
0.666
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-18Client Sample ID: 051-N-02Matrix: SolidDate Collected: 10/26/16 10:23
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.68
(2σ+/-)
0.533
(2σ+/-)
112/29/16 22:4312/27/16 10:20pCi/g0.7461.00
RL MDC
0.501
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-19Client Sample ID: 051-E-01Matrix: SolidDate Collected: 10/26/16 12:58
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.23
(2σ+/-)
0.552
(2σ+/-)
112/17/16 13:3212/14/16 13:08pCi/g0.8441.00
RL MDC
0.536
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-20Client Sample ID: 051-E-02Matrix: SolidDate Collected: 10/26/16 13:01
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.0410 U
(2σ+/-)
0.461
(2σ+/-)
112/30/16 02:0212/27/16 10:20pCi/g0.7831.00
RL MDC
0.461
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 17 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-21Client Sample ID: 051-S-01Matrix: SolidDate Collected: 10/26/16 10:50
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.968
(2σ+/-)
0.503
(2σ+/-)
112/30/16 03:0812/27/16 10:20pCi/g0.7751.00
RL MDC
0.492
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-22Client Sample ID: 051-S-02Matrix: SolidDate Collected: 10/26/16 10:58
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.123 U
(2σ+/-)
0.487
(2σ+/-)
112/30/16 04:1512/27/16 10:20pCi/g0.8231.00
RL MDC
0.487
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-23Client Sample ID: 051-W-01Matrix: SolidDate Collected: 10/26/16 11:05
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.693 U
(2σ+/-)
0.480
(2σ+/-)
112/30/16 05:2112/27/16 10:20pCi/g0.7611.00
RL MDC
0.474
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-24Client Sample ID: 051-W-02Matrix: SolidDate Collected: 10/26/16 11:09
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.103 U
(2σ+/-)
0.461
(2σ+/-)
112/30/16 06:2712/27/16 10:20pCi/g0.7811.00
RL MDC
0.460
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-25Client Sample ID: 047-E-01Matrix: SolidDate Collected: 10/26/16 12:58
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 36.5
(2σ+/-)
4.13
(2σ+/-)
112/30/16 07:3312/27/16 10:20pCi/g0.7771.00
RL MDC
1.25
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 18 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-26Client Sample ID: 047-E-02Matrix: SolidDate Collected: 10/26/16 13:01
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.746 U
(2σ+/-)
0.502
(2σ+/-)
112/30/16 08:4012/27/16 10:20pCi/g0.7981.00
RL MDC
0.495
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-27Client Sample ID: 047-S-01Matrix: SolidDate Collected: 10/26/16 13:09
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 1.78
(2σ+/-)
0.546
(2σ+/-)
112/30/16 09:4612/27/16 10:20pCi/g0.7571.00
RL MDC
0.511
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-28Client Sample ID: 047-S-02Matrix: SolidDate Collected: 10/26/16 13:16
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.311 U
(2σ+/-)
0.472
(2σ+/-)
112/30/16 10:5212/27/16 10:20pCi/g0.7831.00
RL MDC
0.471
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-29Client Sample ID: 047-W-01Matrix: SolidDate Collected: 10/26/16 13:23
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 53.0
(2σ+/-)
5.92
(2σ+/-)
112/30/16 11:5812/27/16 10:20pCi/g0.7901.00
RL MDC
1.48
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-30Client Sample ID: 047-W-02Matrix: SolidDate Collected: 10/26/16 13:26
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.798
(2σ+/-)
0.498
(2σ+/-)
112/30/16 13:0412/27/16 10:20pCi/g0.7881.00
RL MDC
0.491
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 19 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-31Client Sample ID: 047-N-02Matrix: SolidDate Collected: 10/26/16 13:31
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 43.8
(2σ+/-)
4.93
(2σ+/-)
112/30/16 14:1112/27/16 10:20pCi/g0.8321.00
RL MDC
1.40
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-32Client Sample ID: 047-N-02Matrix: SolidDate Collected: 10/26/16 13:35
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 0.948
(2σ+/-)
0.534
(2σ+/-)
112/30/16 15:1712/27/16 10:20pCi/g0.8351.00
RL MDC
0.524
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-33Client Sample ID: 030-106-01Matrix: SolidDate Collected: 10/27/16 08:06
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 41.4
(2σ+/-)
4.67
(2σ+/-)
112/30/16 16:2312/27/16 10:20pCi/g0.7841.00
RL MDC
1.33
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-34Client Sample ID: 030-106-02Matrix: SolidDate Collected: 10/27/16 08:06
Date Received: 10/31/16 09:40
Method: 906.0 - Tritium, Total (LSC)
Analyte
Tritium 10.6
(2σ+/-)
1.26
(2σ+/-)
111/25/16 20:0511/25/16 12:43pCi/g0.5522.00
RL MDC
0.847
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-35Client Sample ID: 030-107-01Matrix: SolidDate Collected: 10/27/16 08:26
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 19.1
(2σ+/-)
2.28
(2σ+/-)
112/30/16 19:4212/27/16 10:20pCi/g0.7871.00
RL MDC
0.964
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 20 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
Client Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Lab Sample ID: 160-19756-36Client Sample ID: 030-107-02Matrix: SolidDate Collected: 10/27/16 08:26
Date Received: 10/31/16 09:40
Method: 906.0 - Tritium, Total (LSC)
Analyte
Tritium 9.97
(2σ+/-)
1.20
(2σ+/-)
111/25/16 21:0811/25/16 12:43pCi/g0.5392.00
RL MDC
0.813
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-37Client Sample ID: 030-108-01Matrix: SolidDate Collected: 10/27/16 08:35
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 12.0
(2σ+/-)
1.54
(2σ+/-)
112/30/16 20:4812/27/16 10:20pCi/g0.8151.00
RL MDC
0.832
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-38Client Sample ID: 030-108-02Matrix: SolidDate Collected: 10/27/16 08:35
Date Received: 10/31/16 09:40
Method: 906.0 - Tritium, Total (LSC)
Analyte
Tritium 9.18
(2σ+/-)
1.12
(2σ+/-)
111/25/16 21:2911/25/16 12:43pCi/g0.5172.00
RL MDC
0.771
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-39Client Sample ID: 030-109-01Matrix: SolidDate Collected: 10/27/16 08:41
Date Received: 10/31/16 09:40
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Analyte
Carbon-14 13.0
(2σ+/-)
1.63
(2σ+/-)
112/30/16 21:5512/27/16 10:20pCi/g0.7881.00
RL MDC
0.838
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
Lab Sample ID: 160-19756-40Client Sample ID: 030-109-02Matrix: SolidDate Collected: 10/27/16 08:41
Date Received: 10/31/16 09:40
Method: 906.0 - Tritium, Total (LSC)
Analyte
Tritium 11.4
(2σ+/-)
1.32
(2σ+/-)
111/25/16 21:4911/25/16 12:44pCi/g0.5342.00
RL MDC
0.860
Dil FacAnalyzedPreparedUnitResult Qualifier
Count Total
Uncert. Uncert.
TestAmerica St. Louis
Page 21 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method: 906.0 - Tritium, Total (LSC)
Client Sample ID: Method BlankLab Sample ID: MB 160-280941/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 281173 Prep Batch: 280941
Tritium
Analyte
U 111/25/16 19:2311/25/16 12:43pCi/g0.460
MDC
2.00
RL
0.2470.247
(2σ+/-) (2σ+/-)
MB
-0.1117
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-280941/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 281173 Prep Batch: 280941
Tritium
Analyte
114-8010910.719.85 1.21 2.00 0.456
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
Client Sample ID: 030-106-02Lab Sample ID: 160-19756-34 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 281425 Prep Batch: 280941
Tritium
Analyte
122-78148F125.319.9710.6 2.59 2.00 0.599
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 030-106-02Lab Sample ID: 160-19756-34 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 281173 Prep Batch: 280941
Tritium
Analyte
10.7812.7210.6 1.50 2.00 0.642
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Method: C-01-1 - Carbon-14 (EERF C-01-1)
Client Sample ID: Method BlankLab Sample ID: MB 160-283916/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 284471 Prep Batch: 283916
Carbon-14
Analyte
U 112/16/16 11:0212/14/16 13:08pCi/g0.824
MDC
1.00
RL
0.4790.479
(2σ+/-) (2σ+/-)
MB
0.03604
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-283916/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 284471 Prep Batch: 283916
Carbon-14
Analyte
124-679983.5384.4 9.20 1.00 0.822
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
TestAmerica St. Louis
Page 22 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method: C-01-1 - Carbon-14 (EERF C-01-1) (Continued)
Client Sample ID: 049-S-02Lab Sample ID: 160-19756-6 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 284704 Prep Batch: 283916
Carbon-14
Analyte
128-29114109.887.010.6 12.0 1.00 0.822
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 061-N-01Lab Sample ID: 160-19756-9 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 284704 Prep Batch: 283916
Carbon-14
Analyte
128-295293.6087.947.6 10.3 1.00 0.836
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 049-S-02Lab Sample ID: 160-19756-6 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 284704 Prep Batch: 283916
Carbon-14
Analyte
12.82F21.7410.6 2.56 1.00 0.809
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Client Sample ID: 061-N-01Lab Sample ID: 160-19756-9 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 284704 Prep Batch: 283916
Carbon-14
Analyte
14.95F13.0447.6 1.65 1.00 0.818
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Client Sample ID: Method BlankLab Sample ID: MB 160-285477/1-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285955 Prep Batch: 285477
Carbon-14
Analyte
U 112/29/16 20:3112/27/16 10:20pCi/g0.781
MDC
1.00
RL
0.4590.459
(2σ+/-) (2σ+/-)
MB
0.03604
MB
Dil FacPrepared AnalyzedUnitResult Qualifier
Uncert.
Count
Uncert.
Total
Client Sample ID: Lab Control SampleLab Sample ID: LCS 160-285477/2-AMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285955 Prep Batch: 285477
Carbon-14
Analyte
124-679781.8884.4 9.02 1.00 0.776
RL MDC(2σ+/-)
LCS LCS
pCi/g
UnitResult Qual %RecAdded
Spike
Limits
%Rec.Uncert.
Total
TestAmerica St. Louis
Page 23 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Sample ResultsTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Method: C-01-1 - Carbon-14 (EERF C-01-1) (Continued)
Client Sample ID: 051-N-02Lab Sample ID: 160-19756-18 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285955 Prep Batch: 285477
Carbon-14
Analyte
128-299889.0388.91.68 9.81 1.00 0.823
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 030-106-01Lab Sample ID: 160-19756-33 MSMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285955 Prep Batch: 285477
Carbon-14
Analyte
128-2989119.587.941.4 13.1 1.00 0.804
RL MDC(2σ+/-)
MS MS
pCi/g
UnitResult Qual %RecAdded
Spike
Result
Sample Sample
Qual Limits
%Rec.Uncert.
Total
Client Sample ID: 051-N-02Lab Sample ID: 160-19756-18 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285955 Prep Batch: 285477
Carbon-14
Analyte
10.571.0781.68 0.514 1.00 0.782
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
Client Sample ID: 030-106-01Lab Sample ID: 160-19756-33 DUMatrix: Solid Prep Type: Total/NAAnalysis Batch: 285955 Prep Batch: 285477
Carbon-14
Analyte
10.9033.7941.4 3.85 1.00 0.789
RL MDC(2σ+/-)
DU DU
pCi/g
UnitResult Qual LimitResult
Sample Sample
Qual
Uncert.
Total
RER
RER
TestAmerica St. Louis
Page 24 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Association SummaryTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
General Chemistry
Analysis Batch: 277247
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid Moisture160-19756-34 030-106-02 Total/NA
Solid Moisture160-19756-36 030-107-02 Total/NA
Solid Moisture160-19756-38 030-108-02 Total/NA
Solid Moisture160-19756-40 030-109-02 Total/NA
Solid Moisture160-19756-34 DU 030-106-02 Total/NA
Rad
Prep Batch: 280941
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp160-19756-34 030-106-02 Total/NA
Solid LSC_Dist_Susp160-19756-36 030-107-02 Total/NA
Solid LSC_Dist_Susp160-19756-38 030-108-02 Total/NA
Solid LSC_Dist_Susp160-19756-40 030-109-02 Total/NA
Solid LSC_Dist_SuspMB 160-280941/1-A Method Blank Total/NA
Solid LSC_Dist_SuspLCS 160-280941/2-A Lab Control Sample Total/NA
Solid LSC_Dist_Susp160-19756-34 MS 030-106-02 Total/NA
Solid LSC_Dist_Susp160-19756-34 DU 030-106-02 Total/NA
Prep Batch: 283916
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp160-19756-1 049-N-01 Total/NA
Solid LSC_Dist_Susp160-19756-2 049-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-3 049-E-01 Total/NA
Solid LSC_Dist_Susp160-19756-4 049-E-02 Total/NA
Solid LSC_Dist_Susp160-19756-5 049-S-01 Total/NA
Solid LSC_Dist_Susp160-19756-6 049-S-02 Total/NA
Solid LSC_Dist_Susp160-19756-7 049-W-01 Total/NA
Solid LSC_Dist_Susp160-19756-8 049-W-02 Total/NA
Solid LSC_Dist_Susp160-19756-9 061-N-01 Total/NA
Solid LSC_Dist_Susp160-19756-10 061-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-11 061-E-01 Total/NA
Solid LSC_Dist_Susp160-19756-12 061-E-02 Total/NA
Solid LSC_Dist_Susp160-19756-13 061-S-01 Total/NA
Solid LSC_Dist_Susp160-19756-14 061-S-02 Total/NA
Solid LSC_Dist_Susp160-19756-15 061-W-01 Total/NA
Solid LSC_Dist_Susp160-19756-16 061-W-02 Total/NA
Solid LSC_Dist_Susp160-19756-17 051-N-01 Total/NA
Solid LSC_Dist_Susp160-19756-19 051-E-01 Total/NA
Solid LSC_Dist_SuspMB 160-283916/1-A Method Blank Total/NA
Solid LSC_Dist_SuspLCS 160-283916/2-A Lab Control Sample Total/NA
Solid LSC_Dist_Susp160-19756-6 MS 049-S-02 Total/NA
Solid LSC_Dist_Susp160-19756-9 MS 061-N-01 Total/NA
Solid LSC_Dist_Susp160-19756-6 DU 049-S-02 Total/NA
Solid LSC_Dist_Susp160-19756-9 DU 061-N-01 Total/NA
Prep Batch: 285477
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp160-19756-18 051-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-20 051-E-02 Total/NA
TestAmerica St. Louis
Page 25 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
QC Association SummaryTestAmerica Job ID: 160-19756-1Client: Decontamination Decommissioning and Envi
Project/Site: MA-15-028
Rad (Continued)
Prep Batch: 285477 (Continued)
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Solid LSC_Dist_Susp160-19756-21 051-S-01 Total/NA
Solid LSC_Dist_Susp160-19756-22 051-S-02 Total/NA
Solid LSC_Dist_Susp160-19756-23 051-W-01 Total/NA
Solid LSC_Dist_Susp160-19756-24 051-W-02 Total/NA
Solid LSC_Dist_Susp160-19756-25 047-E-01 Total/NA
Solid LSC_Dist_Susp160-19756-26 047-E-02 Total/NA
Solid LSC_Dist_Susp160-19756-27 047-S-01 Total/NA
Solid LSC_Dist_Susp160-19756-28 047-S-02 Total/NA
Solid LSC_Dist_Susp160-19756-29 047-W-01 Total/NA
Solid LSC_Dist_Susp160-19756-30 047-W-02 Total/NA
Solid LSC_Dist_Susp160-19756-31 047-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-32 047-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-33 030-106-01 Total/NA
Solid LSC_Dist_Susp160-19756-35 030-107-01 Total/NA
Solid LSC_Dist_Susp160-19756-37 030-108-01 Total/NA
Solid LSC_Dist_Susp160-19756-39 030-109-01 Total/NA
Solid LSC_Dist_SuspMB 160-285477/1-A Method Blank Total/NA
Solid LSC_Dist_SuspLCS 160-285477/2-A Lab Control Sample Total/NA
Solid LSC_Dist_Susp160-19756-18 MS 051-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-33 MS 030-106-01 Total/NA
Solid LSC_Dist_Susp160-19756-18 DU 051-N-02 Total/NA
Solid LSC_Dist_Susp160-19756-33 DU 030-106-01 Total/NA
TestAmerica St. Louis
Page 26 of 26 1/25/2017
1
2
3
4
5
6
7
8
9
10
11
ATTACHMENT 2
SAMPLE LEACHING SUMMARYDATA EVALUATIONFORT MIMS DRIVE
MARYLAND HEIGHTS, MISSOURI
J024002.03
049-N-01* 6.05 / 0.333 18.1049-N-02* 6.11 / 0.196 31.1049-E-01* 18.3 / 0.211 86.7049-E-02* 2.83 / 0.454 6.2049-S-01* 28.9 / 0.178 162.3049-S-02* 10.6 / 0.387 27.3049-W-01* 11.8 / 0.274 43.0049-W-02* 2.09 / 0.135 15.4
061-N-01 47.6 / 0.8 59.5
061-N-02 54.3 / 2.11 25.7
061-E-01 69.3 / 0.934 74.1
061-E-02 56.5 / 1.67 33.8
061-S-01 12.2 / 0.844 14.4061-S-02* 5.17 / 0.446 11.5
061-W-01 31.4 / 0.722 43.4
061-W-02 45.7 / 1.85 24.7
051-N-01 5.21 / 1.05 4.9051-N-02* 1.68 / 0.364 4.6051-E-01* 1.23 / 0.502 2.4051-E-02* 0.041 / 0.459 0.1051-S-01* 0.968 / 0.468 2.0051-S-02* 0.123 / 0.593 0.2051-W-01* 0.693 / 0.374 1.8051-W-02* 0.103 / 0.329 0.3
047-E-01 36.5 / 1.12 32.5047-E-02* 0.746 / 0.807 0.9
047-S-01 1.78 / 0.835 2.1047-S-02* 0.311 / 0.338 0.9
047-W-01 53.0 / 1.52 34.8047-W-02* 0.798 / 0.615 1.2
047-N-01 43.8 / 1.12 39.1
047-N-02 0.948 / 1.27 0.7
*Soil or water result is less than sample detection limit.
Soil / Water
(C-14 pci/g)Sample ID Kd (Desorption)
data/J024002.03 Sample Leaching Summary.xlsx
J024002.03
0.0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
0 10 20 30 40 50 60 70 80
Kd (D
esorption)
Soil C‐14 Concentration (pCi/L)
Sample Leaching Summary
061‐N‐01
061‐N‐02
061‐E‐01
061‐E‐02
061‐S‐01
061‐W‐01
061‐W‐02
051‐N‐01
047‐E‐01
047‐S‐01
047‐W‐01
047‐N‐01
047‐N‐02
ATTACHMENT 3
ATTACHMENT 4
SITE
4,0002,000
SCALE IN FEET
0
AND TOPOGRAPHYSITE LOCATION
Drawn By: WAH
Date: 2-21-17
Ck'd By: KJH
Date: 3-23-17
App'vd By: KJH
Date: 3-24-17
PLATE 1Project NumberJ024002.03
NOTES1. Plan adapted from a 7.5 minute U.S.G.S.
map for Creve Coeur, Missouri quadrangle,last revised in 2015.
Data Evaluation
Maryland Heights, MissouriFort Mims Drive
MW-5
MW-6
MW-7
MW-8
MW-1
MW-3
MW-4
MW-2
LAKESIDE CROSSING COURT
FOR
T M
IMS
DR
IVE
PAGE SERVICE ROAD
Fee Fee Creek
(492.79)
(494.06
(497.72
(496.65)
494
496
498
500
498
Fee Fee Creek
Fee Fee Creek
Tributary to
Tributary to
Tributary to
502
500
(506.36)
(504.57)
(508.16)
(504.50)
506
502
508504
2001000
SCALE IN FEET
GROUNDWATER CONTOUR MAP
Drawn By: WAH
Date: 1-25-17
Project NumberJ024002.03
Data Evaluation
Maryland Heights, MissouriFort Mims Drive
NOTES1. Plan adapted from "2015 Aerial Imagery for
the St. Louis Region" supplied by East-WestGateway Council of Governments.
2. Groundwater elevations are for the uppermostsaturated zone.
3. Surveying performed January 20, 2017.
LEGENDMonitoring Well LocationGroundwater Elevation at Well Location(January 2017)Groundwater Elevation Contour
(504.50)
PLATE 2
Ck'd By: KJH
Date: 3-23-17
App'vd By: KJH
Date: 3-24-17
MW-5
MW-6
MW-7
MW-8
MW-1
MW-3
MW-4
MW-2
LAKESIDE CROSSING COURT
FOR
T M
IMS
DR
IVE
PAGE SERVICE ROAD
Fee Fee Creek
Fee Fee Creek
Fee Fee Creek
Tributary to
Tributary to
Tributary to
DATE5/169/16
12/16
63.532.886.9
DATE5/169/1612/16
Dry105647 DATE
5/169/16
12/16
10151.4118
DATE5/169/16
12/16
NDND19.4
DATE1/17 27.1
DATE1/17 11.8
DATE1/17 ND
DATE1/17 ND
2001000
SCALE IN FEET
Drawn By: WAH
Date: 2-14-17
Project NumberJ024002.03
Data Evaluation
Maryland Heights, MissouriFort Mims Drive
NOTES1. Plan adapted from "2015 Aerial Imagery for
the St. Louis Region" supplied by East-WestGateway Council of Governments.
LEGEND
Monitoring Well Location
Sample Collection Date (Month/Year)
C-14 Concentration in Groundwater
Not Detected
DATE
GROUNDWATERC-14 CONCENTRATIONS IN
ND
PLATE 3
Ck'd By: KJH
Date: 3-23-17
App'vd By: KJH
Date: 3-24-17