Analógico Sense ING · Function Analogic Output Inductive Sensor Diameter 30mm Type of thread...

2
The inductive proximity sensors are electronic devices able to detect the approach of metal parts, components, machine elements, etc. The detection occurs without any physical contact between the sensor and actuator, increasing the life of the sensor by not having moving parts subject to mechanical wear. The sensors of the PA line have 4 to 20mA analog output that is proportional to the distance detected (dist. min: 4mA and max: 20mA) and can be connected directly to CLP. Models: PA 2 - 12 GI 60 - AN - V1 Analogic inductive sensor Nominal Sensor Distance Sn= 2mm / 4mm / 8mm Tube Diameter 12mm, 18mm, 30mm Tube Type GI - Metallic tube Tube Length M12: 60mm M18, M30: 50mm Electric Configuration AN - direct current analogic output-20mA Electric Connection _ - 2-meter PVC cable V1 - M12 connector - 4 pins What is analogic output sensor? Are sensors which have a current generator and whose function is to generate an output that varies with the distance of the actuator element. How to turn the load and meter on? The load must have a maximum impedance 400W, so that the average linearity is maintained within specifications. Graphic Current x Sensor Distance: Signalling Sensors with cable connection have the rear fully illuminated in green, allowing visualization of sensor operation, even over long distances, since models with micro connector has four microleds, also in green. Connections: The sensors are available with analog output cable with 3 wires or M12 connector - 4 pins Sensing Face: It is the surface the electromagnetic fields emerges from. Sensor Distance (S): It is the distance at which, when approaching the sensing face of the actuator, the sensor switches the output state. The actuation distance is due to the coil size. Thus, the sensor distance and the sensor size cannot be simultaneously specified. Nominal Sensor Distance (Rated Sn): It is the theoretical sensor distance, which uses a Standard Target as a trigger and does not consider variations caused by industrialization, Operating Temperature and Supply Voltage. It is the amount in which the proximity sensors are specified. L=D (if 3xSn < D) or L=3xSn (if 3xSn>D) Sn - nominal sensor distance D - Diameter of the area where the electromagnetic field emerges from. Assured Sensor Distance (Assured Sa): It is the sensor distance at which one can safely operate, considering all the variations of industrialization, temperature and operating voltage: Sa £ 72% Sn Standard Target (50010 Standard): It is a normalized actuator used to calibrate a nominal distance sensor during the sensor manufacturing process. Actuator Material: The operational sensor distance also ranges with the type of metal, or is specified for the Iron and Steel or needs to be multiplied by a reduction factor . Hysteresis: The difference between actuation point (when the metal target approaches the sensor face) and the point of disengagement (when the target moves away from the sensor). This value is important because it ensures a difference between the trigger point and disengagement . Built-in : This type of sensor has the electromagnetic field emerging from the sensor face and only allows it to be mounted on a metallic surface. Technical Characteristics : Model PA2-12GI60-AN (-V1) Function Analogic Output Inductive Sensor Diameter 12mm Type of thread M12x1mm Sensor Distance 0,3 to 2mm Standard Target 12x12mm Assembly built-in Analogic Output current Signal Range 4 - 20mA Load < 400W Average Linearity 3% Supply Voltage 15 to 30Vcc Consumption Current £ 20mA Casing nickelled brass Protection Rate IP66, IP67, IP68 Operating Temperature 0º to +70ºC Storage Temperature -30º to +75ºC Thermal Drift £10% Weight 60g cable / 30g connector Connection by cable 2m PVC cable 3 wires 0,16mm² Connection by connector M12 - 4 pins Model PA4-18GI50-AN(-V1) Function Analogic Output Inductive Sensor Diameter 18mm Type of thread M18x1mm Sensor Distance 0,4 to 4mm Standard Target 18x18mm Assembly built-in Analogic Output current Signal Range 4 - 20mA Load < 400W Average Linearity 3% Supply Voltage 15 to 30Vcc Consumption Current £ 20mA Casing nickelled brass Protection Rate IP66, IP67, IP68 Operating Temperature 0º to +70ºC Storage Temperature -30º to +75ºC Thermal Drift £10% Weight 90g cable / 55g connector Connection by cable 2m PVC cable 3 wires 0,31mm² Connection by connector M12 - 4 pins Model PA8-30GI50-AN(-V1) Function Analogic Output Inductive Sensor Diameter 30mm Type of thread M30x1,5mm Sensor Distance 1 a 8mm Standard Target 30x30mm Assembly built-in Analogic Output current Signal Range 4 - 20mA Load < 400W Average Linearity 3% Supply Voltage 15 to 30Vcc Consumption Current £ 20mA Casing nickelled brass Protection Rate IP66, IP67, IP68 Operating Temperature 0º to +70ºC Storage Temperature -30º to +75ºC Thermal Drift £10% Weight 160g cable / 130g connector Connection by cable 2m PVC cable 3 wires 0,50mm² Connection by connector M12 - 4 pins EA3000787A - 04 / 13 INSTRUCTIONS MANUAL Analogic Output Inductive Sensor Rua Tuiuti, 1237 - Cep.: 03081-000 - São Paulo - SP Tel.: (011) 2145-0444 Fax.: (011) 2145-0404 E-mail : [email protected] - http://www.sense.com.br : r o l o c e l b a C - e u l b U B - k c a l b K B - n w o r b N B : n o i t c n u F t u p t u O . n e p O y l l a m r o N - O N Sheet ½ 1mm 1mm L L AN BN (1) BU (3) BK (4) Material Factor Iron or Steel 1,0 Chrome Nickel 0,9 Stainless Steel 0,85 Brass 0,5 Aluminum 0,4 Copper 0,3 d ³ d 0,81xSn Actuator 3-wire cable M12 connector - 4 Pins

Transcript of Analógico Sense ING · Function Analogic Output Inductive Sensor Diameter 30mm Type of thread...

Page 1: Analógico Sense ING · Function Analogic Output Inductive Sensor Diameter 30mm Type of thread M30x1,5mm Sensor Distance 1 a 8mm Standard Target 30x30mm Assembly built-in Analogic

The inductive proximity sensors are electronic devices able to detect theapproach of metal parts, components, machine elements, etc.The detection occurs without any physical contact between the sensorand actuator, increasing the life of the sensor by not having movingparts subject to mechanical wear.The sensors of the PA line have 4 to 20mA analog output that isproportional to the distance detected (dist. min: 4mA and max: 20mA)and can be connected directly to CLP.

Models: PA 2 - 12 GI 60 - AN - V1

Analogic inductive sensor

Nominal Sensor Distance Sn= 2mm / 4mm / 8mm

Tube Diameter12mm, 18mm, 30mm

Tube Type GI - Metallic tube

Tube LengthM12: 60mmM18, M30: 50mm

Electric ConfigurationAN - direct current analogic output-20mA

Electric Connection_ - 2-meter PVC cableV1 - M12 connector - 4 pins

What is analogic output sensor?Are sensors which have a current generator and whose function is togenerate an output that varies with the distance of the actuatorelement.

How to turn the load and meter on?The load must have a maximum impedance 400W, so that the average linearity is maintained within specifications.

Graphic Current x Sensor Distance:

SignallingSensors with cable connection have the rear fully illuminated in green,allowing visualization of sensor operation, even over long distances,since models with micro connector has four microleds, also in green.

Connections:The sensors are available with analog output cable with 3 wires or M12connector - 4 pins

Sensing Face:It is the surface the electromagnetic fields emerges from.

Sensor Distance (S):It is the distance at which, when approaching the sensing face of theactuator, the sensor switches the output state. The actuation distance is due to the coil size. Thus, the sensor distance and the sensor sizecannot be simultaneously specified.

Nominal Sensor Distance (Rated Sn):It is the theoretical sensor distance, which uses a Standard Target as atrigger and does not consider variations caused by industrialization,Operating Temperature and Supply Voltage. It is the amount in whichthe proximity sensors are specified.

L=D (if 3xSn < D) orL=3xSn (if 3xSn>D)Sn - nominal sensor distanceD - Diameter of the area where theelectromagnetic field emerges from.

Assured Sensor Distance (Assured Sa):It is the sensor distance at which one can safely operate, considering all the variations of industrialization, temperature and operating voltage:

Sa £ 72% Sn

Standard Target (50010 Standard):It is a normalized actuator used to calibrate a nominal distance sensorduring the sensor manufacturing process.

Actuator Material:The operational sensor distancealso ranges with the type of metal,or is specified for the Iron and Steelor needs to be multiplied by areduction factor .

Hysteresis:The difference between actuation point (when the metal targetapproaches the sensor face) and the point of disengagement (when the target moves away from the sensor). This value is important because itensures a difference between the trigger point and disengagement .

Built-in :This type of sensor has the electromagnetic field emerging from thesensor face and only allows it to be mounted on a metallic surface.

Technical Characteristics :

Model PA2-12GI60-AN (-V1)

Function Analogic Output Inductive Sensor

Diameter 12mm

Type of thread M12x1mm

Sensor Distance 0,3 to 2mm

Standard Target 12x12mm

Assembly built-in

Analogic Output current

Signal Range 4 - 20mA

Load < 400W

Average Linearity ± 3%

Supply Voltage 15 to 30Vcc

Consumption Current £ 20mA

Casing nickelled brass

Protection Rate IP66, IP67, IP68

Operating Temperature 0º to +70ºC

Storage Temperature -30º to +75ºC

Thermal Drift £10%

Weight 60g cable / 30g connector

Connection by cable 2m PVC cable 3 wires 0,16mm²

Connection by connector M12 - 4 pins

Model PA4-18GI50-AN(-V1)

Function Analogic Output Inductive Sensor

Diameter 18mm

Type of thread M18x1mm

Sensor Distance 0,4 to 4mm

Standard Target 18x18mm

Assembly built-in

Analogic Output current

Signal Range 4 - 20mA

Load < 400W

Average Linearity ± 3%

Supply Voltage 15 to 30Vcc

Consumption Current £ 20mA

Casing nickelled brass

Protection Rate IP66, IP67, IP68

Operating Temperature 0º to +70ºC

Storage Temperature -30º to +75ºC

Thermal Drift £10%

Weight 90g cable / 55g connector

Connection by cable 2m PVC cable 3 wires 0,31mm²

Connection by connector M12 - 4 pins

Model PA8-30GI50-AN(-V1)

Function Analogic Output Inductive Sensor

Diameter 30mm

Type of thread M30x1,5mm

Sensor Distance 1 a 8mm

Standard Target 30x30mm

Assembly built-in

Analogic Output current

Signal Range 4 - 20mA

Load < 400W

Average Linearity ± 3%

Supply Voltage 15 to 30Vcc

Consumption Current £ 20mA

Casing nickelled brass

Protection Rate IP66, IP67, IP68

Operating Temperature 0º to +70ºC

Storage Temperature -30º to +75ºC

Thermal Drift £10%

Weight 160g cable / 130g connector

Connection by cable 2m PVC cable 3 wires 0,50mm²

Connection by connector M12 - 4 pins

EA3000787A - 04 / 13

INSTRUCTIONS MANUAL

Analogic Output Inductive Sensor

Rua Tuiuti, 1237 - Cep.: 03081-000 - São Paulo - SP Tel.: (011) 2145-0444 Fax.: (011) 2145-0404 E-mail : [email protected] - http://www.sense.com.br

:rol

oc

elb

aC

- e

ulb

UB -

kc

alb

KB -

nw

orb

NB

:n

oitc

nu

F tu

ptu

O.

ne

pO yll

amr

oN -

ON

Sheet ½

1mm1mm

LL

ANBN (1)

BU (3)

BK (4)

Material FactorIron or Steel 1,0

Chrome Nickel 0,9Stainless Steel 0,85

Brass 0,5Aluminum 0,4

Copper 0,3

d ³ d 0,81xSn

Actuator

3-wire cable M12 connector - 4 Pins

Page 2: Analógico Sense ING · Function Analogic Output Inductive Sensor Diameter 30mm Type of thread M30x1,5mm Sensor Distance 1 a 8mm Standard Target 30x30mm Assembly built-in Analogic

Mechanical DimensionsM12 Models

M18 Models

M30 Models

General Precautions:Connection Cable :Prevent the cable connecting the sensor is subjected to any mechanical stress.

Oscillation:As the sensors have resin, they can be used in machines withmovements, only by fixating the cable together with the sensor throughclamps, allowing only the middle of the cable to oscillate.

Fixing Bracket:Prevent the sensor from suffering impacts with other parts or piecesand not be used as support.

Moving Parts:During installation, carefully observe the sensor distance and position,thus avoiding impacts to the actuator.

Fixing Nuts:Avoid over-tightening the fixing nuts.

Chemical Products:In installations in harsh environments, we suggest contacting ourtechnical dept, to specify the most suitable sensor for the application.

Environmental Conditions:avoid subjecting the sensor to ambient conditions with operatingtemperature above the sensor limits.

EA3000787A - 04 / 13Sheet 2/2

5050

NN