Alarm & Status

11
45 Alarm & Status iPASOLINK Introduction

description

iPaso Alarm & status

Transcript of Alarm & Status

  • 45

    Alarm & Status

    iPASOLINK Introduction

  • 4646

    ODU Alarm and Status

    Indication Category Descriptions SeverityTXPWR ALM Alarm The TX PWR is lower than 3 dB. MJTX INPUT ALM Alarm The TX IF signal become out of range from

    -29 dBm 5 dB.MJ

    RXLEV ALM Alarm The reception level become lower than -72dBm ~ -94dBm level.(It depends on the modulation system and bit rates).

    MJ

    ODU CPU / Cable Open

    AlarmCPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken or is not connected.

    MJ

    MUTE STATUS StatusIndicates the control status of the ODU TX power output. When the TX power is set to Mute, Status is issued.

    -

    LO REF Alarm Loss of Ref LO signal of ODU. MN

    TX SW Status Status Radio interface TX SW usage state in 1+1 HS Redundant configuration -

    ODU ALM AlarmIndicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM, ODU SELF CHECK ALM occurrence

    MJ

    ODU TOTAL ALM AlarmIndicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.

    Highest severity will be displayed

    ATPC Power Mode

    StatusATPC control signal fault (90sec) as well as MAX Power continuation 90sec

    -

    ODU TYPE MISMATCH

    AlarmIndicate connected ODU type is not supported at iPASOLINK system, or ODU type cannot use in provisioned modulation setting.

    MJ

    ODU PS ALM Alarm ALM in a case of Power supply interruption to ODU. MJODUPS SET STATUS

    Status Status indication of the protection switch for ODU power supplies -

    iPASOLINK Introduction

  • 4747

    Modem Alarm and Status

    Indication Category Descriptions Severity

    Unequipped (MODEM-A) Alarm Reserved and installed optional package is removed from optional slot. MJType Mismatch(MODEM-A) Alarm The equipped type of interface is different from configured type. MJ

    Communication FAIL(MODEM-A) Alarm Communication failure of equipment internal control communication. MJ

    Module(MODEM-A) Alarm Equipment fault MJ

    BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ

    BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ

    RXSW STATUS Status Radio interface RX SW usage state in Redundant configuration -

    LOSS OF FRAME Alarm Loss of Frame at radio side. MJ

    FRAME ID Alarm Frame ID (route differentiation ID) MJ

    HIBER ALM Alarm Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5) MJ

    LOBER ALM Alarm Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9) MN

    EARLY WARNING Alarm Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9) MN

    MOD Alarm Indicates the operating status of the MOD. When any failure occurs in the modulator section, Alarm is issued. MJ

    IF CABLE SHORT Alarm IF cable between IDU - ODU is in short condition. MJ

    INPHASE. Status In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase condition. In this condition, hitless switch over is available.

    -

    L2SYNC LOSS Alarm Loss of frame synchronization of GFP frames on MODEM port. MJ

    RDI Alarm RDI indication reception alarm on MODEM port MJ

    UAE. Alarm UAE alarm. Indicates the occurrence of an Unavailable state. MN

    TDM/AMR Range Mismatch Alarm Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or mismatch condition of selected RX AMR modulation range and TX AMR modulation range.

    MJ

    TX SW Reverse Request Status TXSW request signal receiving condition from the opposite station: -

    TX SW Lock in Status Status TXSW Lockin state -

    Unlocked Alarm Wireless synchronization status of the local side. MJ

    MODEM PS OFF Status Indicate power off condition of power switch which is in front of MODEM-A card. -

    iPASOLINK Introduction

  • 4848

    STM-1 Alarm and Status

    Indication Category Descriptions Severity

    Unequipped (STM1-A) Alarm Reserved and installed optional package is removed from optional slot. MJ

    Type Mismatch(STM1-A) Alarm The equipped type of interface is different from configured type. MJ

    Communication FAIL(STM1-A) Alarm Communication failure of equipment internal control communication. MJ

    Module(STM1-A) Alarm Equipment fault MJ

    BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ

    BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ

    SNCP PPS-FAIL Alarm. SNCP Path Protection Failure MJ

    SNCP Protection Status Status SNCP Path Protection Status indication which indicates [FS, SF, SD, MS, NR] condition. -

    APS Protection Status Status APS Line Protection Status indication which indicates {FS,SF,SD,MS,NR} condition. -

    APS Lock-in Status Status APS protection Lock-in Condition. -

    SFP_Type Mismatch (STM1) Alarm Mismatch between SFP on LCT and installed SFP. MJ

    SFP Unequipped (STM1) Alarm A SFP is removed. MJ

    STM-1LOS Alarm LOS detection on STM-1 Optical port. MJ

    STM-1 TF Alarm Transmit Failure detection on STM-1 optical port. MJ

    RS LOF Alarm SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port. MJ

    RS TIM Alarm Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port. MJ

    RS EXC Alarm B1 Byte error occurrence in RS (Regenerator Section) on STM-1 port. MJ

    RS DEG Alarm B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port. MN

    MS AIS Alarm AIS detection in MS (Multiplex Section) on STM-1 port. MJ

    MS RDI Alarm Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port. MJ

    AU AIS Alarm AIS detection in AU (Administrative Unit) on STM-1 port. MJ

    iPASOLINK Introduction

  • 4949

    STM-1 Alarm and Status

    Indication Category Descriptions Severity

    AU LOP Alarm Loss of AU pointer happens on STM-1 port. MJ

    HP UNEQ Alarm HOP (Higher Order Path) Unequipped occurrence on STM-1 port. MJ

    HP TIM Alarm HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port. MJ

    HP-PLM Alarm Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port. MJ

    HP-RDI Alarm RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port. MJ

    HP-LOM Alarm Loss of Multi-Frame on STM-1 port. MJ

    TU -AIS Alarm In TU (Tributary Unit), AIS detection on STM-1 port. MJ

    TU -LOP Alarm Loss of TU Pointer on STM-1 port. MJ

    LP -UNEQ. Alarm LP (Lower Order Path) Unequipped occurrence on STM-1 port. MJ

    LP RDI Alarm Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port. MJ

    LP PLM Alarm Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port. MJ

    ALS Status Indication of automatic laser shutdown condition at STM-1 optical port. -

    RS UAS Status Status UAS status indication on STM port (Repeater Section) -

    STM-1 AIS Generated Status AIS generation condition on STM port. -

    PJE Status Pointer justification Event indication at STM port. -

    iPASOLINK Introduction

  • 5050

    16E1 alarm and Status

    Indication Category Descriptions Severity

    Unequipped (16E1) Alarm Reserved and installed optional package is removed from optional slot. MJ

    Type Mismatch(16E1) Alarm The equipped type of interface is different from configured type. MJ

    Communication FAIL(16E1) Alarm Communication failure of equipment internal control communication. MJ

    Module(16E1) Alarm Equipment fault MJ

    BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ

    BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ

    E1 LOS Alarm No signal input on E1 port MJ

    E1 AIS Status ALARM/Status category can change according to " AIS Received Condition Setting

    MJ / -

    Usage Error Alarm Unused E1 CH input signal detection. MN

    E1 AIS Generated Status AIS generation condition on every E1 Channels. -

    iPASOLINK Introduction

  • 5151

    AUX-A Option Card

    Indication Category Descriptions Severity

    Unequipped (AUX-A) Alarm Reserved and installed optional package is removed from optional slot.

    MJ

    Type Mismatch(AUX-A) Alarm The equipped type of interface is different from configured type.

    MJ

    Communication FAIL(AUX-A)

    Alarm Communication failure of equipment internal control communication.

    MJ

    Module(AUX-A) Alarm Equipment fault MJ

    BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card.

    MJ

    BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card.

    MJ

    Item Name (Input-x)Item Name (Cluster-x)

    Status/Alarm

    HKA Status Indication {Alarm, Normal} for every HKA input.

    - orSeverity selectable

    Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -

    iPASOLINK Introduction

  • 5252

    GbE-A option card

    Indication Category Descriptions Severity

    Unequipped (GBE-A) Alarm Reserved and installed optional package is removed from optional slot.

    MJ

    Type Mismatch(GBE-A)

    Alarm The equipped type of interface is different from configured type.

    MJ

    Communication FAIL(GBE-A)

    Alarm Communication failure of equipment internal control communication.

    MJ

    Module(GBE-A) Alarm Equipment fault MJ

    BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card..

    MJ

    BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card..

    MJ

    SFP_Type Mismatch (ETH)

    Alarm Mismatch between SFP on LCT and installed SFP.

    MJ

    SFP Unequipped (ETH)

    Alarm A SFP is removed. MJ

    LAN LINK Alarm LINK of the LAN Port is disconnected. MJ

    Speed & Duplex Status LAN Port setting (Speed&Duplex) -

    iPASOLINK Introduction

  • 5353

    Equipment Common alarm and Status-1

    Indication Category Descriptions Severity

    MODULE (Main Board) Alarm Equipment fault MJ

    BUS ERROR Alarm Data communication BUS failure condition. MJ

    Unequipped (PS) Alarm Installed Power Supply Module is removed from PS slot. MJ

    Power Supply Alarm Alarm in case of power failure. MJ

    FAN Fail Alarm FAN failure MJ

    Unequipped (FAN) Alarm Installed FAN Module is removed from FAN slot. MJ

    Unequipped (CLK2M) Alarm Installed CLK2M Module is removed from Main Card. MJ

    Type Mismatch (CLK2M) Alarm The equipped type of interface is different from configured type. MJ

    IDU CPU Alarm Alarm. IDU CPU Alarm MN

    Memory Failure Alarm Detection of memory failure MJ

    USB Failure Alarm USB memory failure indication MJ

    Temperature Alarm The temperature is over the threshold MN

    Maintenance Status Maintenance declaration. -

    CLK FAIL Alarm Reference Clock Failed. MN

    CLK Drift Alarm Reference Clock source Frequency drift condition MN

    LTI Alarm Loss of all incoming timing source MJ

    CLK Status Changed Status Reference clock change status(1) (Locked Ref1)(2) (Locked Ref2)(3) (Locked Ref3)(4) Holdover(5) Freerun

    -

    SSM FAIL Alarm Received Sync Status Message value is in unstable condition. MN

    Quality Level Status Received quality level condition of each timing source. -

    Squelch Status The condition of External CLK Output is in squelch condition. -

    iPASOLINK Introduction

  • 5454

    Equipment common Alarm and Status -2

    Indication Category Descriptions Severity

    EXT CLK Condition Status Condition level of External CLK output. -

    EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN

    EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input. MN

    EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN

    EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output. MJItem Name (Input-x)Item Name (Cluster-x)

    Status/Alarm HKA Status Indication {Alarm, Normal} for every HKA input.

    - or Severity selectable

    Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -

    E1 LOS Alarm No signal input on E1 port MJ

    E1 AIS StatusPDH AISALARM/Status category can change according to " AIS Received Condition Setting MJ / -

    Usage Error Alarm Unused E1 CH input signal detection. MN

    E1 AIS Generated Status AIS generation condition on every E1 Channels. -

    ETH LOS Alarm LOS detection at Optical Ethernet port. MJ

    ETH TF Alarm Transmit Fail detection at Optical Ethernet port. MJ

    SFP_Type Mismatch (ETH) Alarm Mismatch between SFP on LCT and installed SFP. MJ

    SFP Unequipped (ETH) Alarm A SFP is removed. MJ

    LAN LINK Alarm LINK of the LAN Port is disconnected. MJ

    Speed & Duplex Status LAN Port setting (Speed&Duplex) -

    ETH-OAM LOC Alarm MJ

    ETH-OAM Mismerge Alarm Ether OAM Mismatch Detection notice. MN

    ETH-OAM Unexpected Period Alarm Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice MN

    ETH-OAM RDI Alarm Ether OAM RDI reception detection notice MJ

    iPASOLINK Introduction

  • 5555

    Equipment common Alarm and Status -3

    Indication Category Descriptions Severity

    RSTP New Root Bridge Detect Status The notice in which new RootBridge was detected at the time of SpanningTree processing -

    RSTP Topology Changed Status The notice in which a Topology change was detected at the time of SpanningTree processing -

    RSTP Protocol Migration StatusThe notice which received a Bridge protocol Data Units different in classification of RSTP/STP at the time of SpanningTree processing -

    RSTP Invalid BPDU Received Status Invalid BPDU message at the time of SpanningTree processing -

    LLF Message Timeout StatusLoss of a conditional signaling in which the LLF control signal should be received continuously from the opposite radio equipment.

    LLF Status LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN. -

    IDU TOTAL ALM Alarm IDU TOTAL ALM

    The highest Severity will be reported

    Total FDB Full Status The number of DynamicEntryDynamic Entry in L2Switch has reached the maximum number.

    FDB Full Status FDB Full indication specified per VLAN basis.

    iPASOLINK Introduction