IK Insulation Group - Corporate - 2009
Praval Adhaulia
K-FLEX INDIA PVT LTD
-
7/25/2019 AIC Tech Praval
2/21
IK Insulation Group - Corporate - 2008
Thermal and Acoustic Products
-
7/25/2019 AIC Tech Praval
3/21
ThermalInsulation
Is a material having relatively high resistance to heat flow
Stationary air is common in all the insulating materials providingthe insulation effect.
Advantages
Energy Conservation Minimizes Heat Loss
Control / Prevent Surface Condensation - Cold applications
Control Surface temperatures Hot applications.
-
7/25/2019 AIC Tech Praval
4/21
Efficient Thermal Insulations
IK Insulation Group - Corporate - 2008
Reduction in
Losses
CFC / HCFC
Free
Decrease in
load on HVAC
systems
Efficient use of
Electrical
power
Cost savings due to
more efficient system
performance
Lesser energy
intake
A Greener Environment
-
7/25/2019 AIC Tech Praval
5/21
Health & Environmental aspects
IK Insulation Group - Corporate - 2008
FIBRE
FREE
-
7/25/2019 AIC Tech Praval
6/21
Commonly used HVAC Insulation Materials
Elastomeric Nitrile Rubber
Closed CellThermal Insulation
Open CellAcoustic Insulation
IK Insulation Group - Corporate - 2008
Glass wool
XLPE
-
7/25/2019 AIC Tech Praval
7/21
ParametersforSelection
Thermal conductivity
Water Vapor ingress resistance
Fire / Safety Properties
Ease of Installation
Environmental Friendly
Installation and after sales support
-
7/25/2019 AIC Tech Praval
8/21
Thermal Conductivity should be as low as
possible
Water Vapour Diffusion resistance should be as
high as possible
IK Insulation Group - Corporate - 2008
7000 = 1220
Year 0 0.036 @ 0C 0.036@ 0C
Year 2 0.0374 0.0413
Year 4 0.0380 0.0467
Year 6 0.0394 0.0520
Year 8 0.0405 0.0574
Year 10 0.0412 0.0627
-
7/25/2019 AIC Tech Praval
9/21
Fire
Hazards in the event of a Fire?
Spread of Fire to the entire establishment.
Smoke!!
Speed of Fire Spread.
Fire Requirements of an Insulation Material.
Min./Nil Growth & Spread of Fire.
Smoke should be non-toxic.
Should not produce flaming drops.
Fire Behaviour is governed by Each Countries Fire Codes.
FM/BS/DIN/UL etc.
-
7/25/2019 AIC Tech Praval
10/21
Environmental & Health Friendly
Green Building Codes / Other Building codes
IAQ - Should be smooth surface and inhibit build of dirt and possible
contaminations.
CFC's, HFC's or HCFC's, VOC/SVOC free
ODP of ZERO
Should be formaldehyde freeNon toxic
-
7/25/2019 AIC Tech Praval
11/21
Advantages of Nitrile Insulation
Closed Cell Insulation Material
FM Global Approved
Fire rating class O
Lower Thermal Conductivity
Higher Density
High Water Diffusion Resistance
Flexible
Wide range of operating temperature
In-built vapour barrier
Ultrafresh
IK Insulation Group - Corporate - 2008
Uniform Bonding & Constant Insulation Value
Higher Safety against fire
Self Extinguishing, non Dripping
Higher Resistance to Heat Transfer
Higher Stability Long Term Insulation Efficiency With Lower
Thickness
Reduced Cost & Ease of Installation
One Product For Various Applications
Increased resistance to water ingress Resistant to Fungal and bacterial growth
Features Benefits
-
7/25/2019 AIC Tech Praval
12/21
FibreglassPARAMETERS FIBRE GLASS
Thermal Conductivity 0.035 W/m @ O DegC
Fire Resistance Class O / FM approval
Ageing Heavy deterioration in thermal properties with time on
account of humid conditions. Fiber glass also supports the
growth of mildew, fungus and bacteria.
Service Temperature - 195 to 225 Deg C
Water Vapour Transmission Requires cladding to protect from moisture ingress
Water Absorption Extremely high.
Health and Safety
Contains fibers and can enter the air stream.
Installation Time consuming and not installer friendly
Cost Economic
IK Insulation Group - Corporate - 2008
-
7/25/2019 AIC Tech Praval
13/21
XLPE
Parameter
Crosslinked Polyethylene
Closed Cell Structure > 90%
Density
30 +/- kgs /m3
Temperature range -40 to +110 deg C
Thermal Conductivity at 0 deg C
0.036 W/ (m.K) @ 0degc
Mositure Resistance Factor
EN 12086 (DIN 52 615) > 2190
Water Vapour Permeability- 0.15 x 10exp-12 Kg/(m.s.Pa)
Under Insulation Corrosion
Possible
Fire Performance
Burns with flaming drops. Drips
Ozone Resistance Good
Noise Reduction No data.
Installation
Moderately flexible
IK Insulation Group - Corporate - 2008
-
7/25/2019 AIC Tech Praval
14/21
Acoustics : Frequency spectral coverage of some
typical noise sources
-
7/25/2019 AIC Tech Praval
15/21
Acoustics in HVAC equipments
Air Terminals / Diffusers
Fan coil units / Air Handling Units
Roof top units
Chillers
Heat Pumps / Pumps
Cooling towers VAV boxes
others
IK Insulation Group - Corporate - 2008
-
7/25/2019 AIC Tech Praval
16/21
K-FLEX INDIA 2013 Amit
Nitrile
Open Cell Material for SoundAbsorption
Ideal for
Duct Lining,
FCU / AHU
AHU / Mechanical Rooms,
VAV Boxes
Pumps
Compressors
Generators,
Enclosures Lining,
Industrial Noise Control,
Marine & Offshore Applications
-
7/25/2019 AIC Tech Praval
17/21
Fiberglass
IK Insulation Group - Corporate - 2008
Applications are
FCU / AHUAHU / Mechanical Rooms,
Under deckWall InsulationsGeneratorsEnclosures Lining
-
7/25/2019 AIC Tech Praval
18/21
K-FLEX INDIA 2013 Amit
Accessories
-
7/25/2019 AIC Tech Praval
19/21
Insulation thickness Calculation
K-FLEX INDIA 2013 Amit
http://localhost/var/www/apps/conversion/tmp/scratch_6/K-FLEX%20isocalc/Calcolo01.exe -
7/25/2019 AIC Tech Praval
20/21
Installation Training
K-FLEX INDIA 2013 Amit
http://localhost/var/www/apps/conversion/tmp/scratch_6/Installation%20CD/start.exe -
7/25/2019 AIC Tech Praval
21/21
Thank You !!
IK Insulation Group - Corporate - 2008
K-FLEX NITRILE GLASSWOOL
XLPE
Accessories
Services
The Insulation Experts
With you !