Advanced Methods for Open Path FTIR Technology
Research Update
Dr. Susan Stuver February 2015
![Page 2: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/2.jpg)
Project Goal How to measure fugitive emissions when
you don’t know what’s in the air to begin with Gas Analyzers measure only one pollutant Photo Ionization Detectors can’t source emissions
and can be inaccurate Canisters only give a snapshot Open Path Systems can: Detect 100s of gases, continuously operate,
includes meteorological data, withstand harsh weather System is being used by DoD to detect and
measure chemical threats
However, existing protocol for the use of open path technology
in oil and gas operations is outdated
![Page 3: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/3.jpg)
Project Goal – Develop Protocol Short Term Monitoring Drilling Fracturing
Long Term Monitoring Production Compression
2 Phases Phase 1: Controlled Methane Release Phase 2: Oil and Gas Field Trials
![Page 4: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/4.jpg)
How an OP-FTIR Works OP-FTIR System is like a
particle counter summing up total energy that given chemicals absorb at a particular wavelength
The energy measurement is compared against known spectra which is converted into a path averaged concentration
Weather data are integrated to give us the direction toward the source
![Page 5: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/5.jpg)
How an OP-FTIR Works ad nauseam
• A beam of light spanning a range of wavelengths in the near-IR portion of the electromagnetic spectrum (approximately 2 to 14 microns) is propagated from the transmitter.
• a retroreflector comprised of an array of corner-cubed mirrors, is
positioned to intercept this radiation and redirect it back upon itself to the receiver.
• An interferometer splits the returning beam into two paths, and
recombines them in a way to generate an interference. The interference, is dependent on the wavelengths present in the beam.
• In one of the paths, the radiation is reflected off a moving mirror,
resulting in an intensity variation which is measured as a function of the path difference between the two mirrors; the result is an interferogram.
![Page 6: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/6.jpg)
How an OP-FTIR Works ad nauseam
• The interferogram that is obtained from a monochromatic beam is a simple cosine wave.
• The broadband interferogram is a sum of cosine waves (the Fourier series) for each spectral component as a function of mirror-beam-path separation.
• A spectrum in the optical frequency units is obtained by performing a Fourier transform upon the interferogram.
• Contaminants of concern are identified and quantified via a computer-based spectral search involving sequential, compound-specific analyses and comparison to the system’s internal reference spectra library.
• FTIR spectral data is analyzed via multi-component classical least squares (CLS) technique.
• Any gaseous compound which absorbs in the IR region is a potential candidate for monitoring using this technology.
![Page 7: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/7.jpg)
Phase 1 Primary Equipment
Kassay RAM 2000 G2 and 37 Cube Retroreflector Heavy duty tripods
Climatronix Integrated F460 Weather Station Copper grounding rod
RM Young 3D Ultrasonic Anemometer Meteorological Translator
![Page 8: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/8.jpg)
Phase 1 Primary Equipment Methane Release System
Methane Cylinders 2 Stage Regulator AALBORG Mass Flow
Controller Teflon Tubing Swagelok fittings and Snoop Bucket Release System Stabilization Cart
Generac Inverter Generator Gasoline powered
![Page 9: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/9.jpg)
Phase 1 Primary Equipment Air Gas Methane Release
System Methane Cylinders 2 Stage Regulator AALBORG Mass Flow
Controller Teflon Tubing Swagelok fittings and Snoop Bucket Release System Cart
Solar Powered Generator
![Page 10: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/10.jpg)
Phase 1 Remote Power Solar Powered
Generator Deep Cycle Battery Battery Box Solar Power Intelligent
Photovoltaic Controller Raptor 1000-3000 watt
power inverter
Gasoline generators not allowed in explosive environments
Diesel generators push too much current for sensitive instrumentation
![Page 11: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/11.jpg)
Phase 1 Secondary Equipment Laptops – one for the OP-FTIR, one for the Anemometer Extension Cords – 100 foot and 50 foot Surge Protector – 6 plugs works best Grounding Supplies – clamps, wire, rod and cutters Compass – finding true north GPS – instrumentation coordinates for modeling Measuring Wheel or Range Finder – beam path
measurement Equipment dollies and Storage Containers – Safe movement
– horse trailer works best Folding table and Canopy – work station
![Page 12: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/12.jpg)
Other Stuff that makes life easier…
First Aid, bug spray, sunblock, extra water, snacks, shade structure, small fan, space heater, cooler
Camera, phones, tablets, internet connectivity Chairs – at least 4 Stakes – at least 12 Rope – tie downs Tarps, canopies or plastic sheeting – in case it rains Tape – duct, electrical, thread Flashlights Small ladder – weather station adjustment Tool box with at least:
Multiple size wrenches, crescent wrench, Allen wrenches – both English and metric, hammer, zip ties, scissors, wire cutters
![Page 13: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/13.jpg)
Site Design: Controlled CH4 Release
Retroreflector
Methane release
F460 Weather
Anemometer
OP-FTIR
![Page 14: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/14.jpg)
Site Design: Pilot Test
![Page 15: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/15.jpg)
Instrument Prep: Chemical Setup Potential to measure 100’s of analytes
For simplicity, 11 were chosen
Benzene, Toluene, Ethylbenzene, O-Xylene, M-Xylene, P-Xylene, Propane, Ammonia, Carbon Monoxide, Methanol, Methane, Water- chosen as an interferent
An interferent is a chemical with a spectral
region that overlaps the chemicals you wish to analyze. Interferents (like water vapor) can cause erroneous concentration readings unless they are mathematically removed from the analysis.
![Page 16: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/16.jpg)
Instrument Prep: Water Vapor RMMSoft automatically adjusts for water vapor present in all sample spectra. Water vapor is “cancelled” from each spectral frame (background subtraction) due to the presence of water vapor in the background data, as well as the actual data run. Additionally, water vapor is listed as an interferent for every analyte of interest, and is algorithmically accounted for in each sample frame. (Section 9.11 EPA Method TO-16).
![Page 17: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/17.jpg)
Chemical Setup - Screenshot
Concentrations shown as a “C” in their known spectral regions
Water Vapor is an interferent and is shown as an “I” in its known spectral regions. An “I” can be assigned to any chemical you wish to remove from the analysis
![Page 18: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/18.jpg)
Instrument Prep: QA/QC Noise Equivalent Absorption (NEA)
NEA evaluates the performance of the system – think of it as laser-based diagnostics.
During an NEA analysis, the program will compute the Mean, Maximum and Standard Deviation of the NEA in 3 spectral regions and will automatically evaluate each against a pre-defined tolerance.
If any regions’ mean is greater than the tolerance, the NEA Noise for that region is marked as Out of Spec.
![Page 19: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/19.jpg)
Lots More QA/QC
Measurement of Return Beam Intensity (S/N, saturation sampling tests)
Measurement of Stray Light Instrument Detection Limit
Determination of Precision
Determination of Accuracy
Measurement of Resolution
Determination of Non-linear Instrument Response
Demonstration of Capability (DOC)
![Page 20: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/20.jpg)
Spectral Interference
Water molecules, present in heavy fog or rain, may saturate the modulated signal received at the detector. The absorbance of water covers a broad wave number region and overlaps with regions of other gases. “NO DATA”, will register on the software display, as a result of the saturation.
Heavy precipitation or condensation on the Retro-reflector may create physical interferences in the energy pathway, which result in degraded voltages. If the voltage is low enough that “NO DATA” readings occur, sampling may need to be halted until rain reduces or stops.
Below is a super fancy way of saying “This Instrument doesn’t work in the rain”
![Page 21: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/21.jpg)
Aligning the Instrument Good alignment has peak-
to-peak beam signal strength of 5 to 18 volts.
If the beam strength is too low, accuracy will be compromised.
If the beam strength is too high, peaks may become saturated meaning that the spectral results could display significant peak noise resulting in poor results.
![Page 22: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/22.jpg)
Establishing a Background
“background” is taken and used as reference spectrum for Classical Least Squares processing. In order to properly detect and quantify chemicals present in the atmosphere, the background spectrum must be devoid of all traces of the target chemicals.
background spectrum is always collected as an interferogram - a time-domain waveform produced by the optical path difference of the interferometer. Interferograms can be Co-Added to increase the Signal-to-Noise Ratio of the signal.
![Page 23: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/23.jpg)
Spectra and Concentration Data Study Site 1 – CH4 Release
![Page 24: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/24.jpg)
Concentration Rose Study Site 1 – CH4 Release
![Page 25: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/25.jpg)
Spectra and Concentration Data Study Site 2 – Pilot Test
![Page 26: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/26.jpg)
Spectra and Concentration Data Study Site 2 – Pilot Test
![Page 27: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/27.jpg)
Concentration Rose Study Site 2 – Pilot Test
![Page 28: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/28.jpg)
Phase 2 Field Test Sites
Study site 1 will be a drilling rig
Study site 2 will be an Eagle Ford well pad
Study site 3 will be Eagle Ford processing plants
![Page 29: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/29.jpg)
Develop protocol that includes: OP-FTIR short term and long term monitoring Data control and accuracy Data analysis, concentration rose and plume modeling
Develop Emission Rates from Path Integrated Concentrations
Phase 2 Goals
So in addition to this… We have this…
![Page 30: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/30.jpg)
Logic Mapping for Phase 2
![Page 31: Advanced Methods for Open Path FTIR Technologyefdsystems.org/pdf/09_Stuver_Advanced_Methods_for... · Advanced Methods for Open Path FTIR ... Small ladder – weather station ...](https://reader031.fdocuments.us/reader031/viewer/2022022014/5b4179bd7f8b9ac2668b49f8/html5/thumbnails/31.jpg)
Questions?