Linear actuatorEcomag
BenefitsCompact$PTUFGGFDUJWF4JMFOUPQFSBUJPO$POUSPMVOJUDBOCFNPVOUFEUPUIFBDUVBUPS
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsEcomag
+24 V DC
MActuator
Limit switches
RedBlack
Suitable control units and accessories
Connecting diagram
Technical data
Unit ECO 20/40 ECO 60/80 ECO 30/50 ECO 70/90
Rated push load N 2 000 6 000 2 000 6 000Rated pull load N 0 0 2 000 4 000Speed (full load to no load) mm/s 9 to 13 4 to 7 9 to 13 4 to 7Stroke mm 50 to 300 50 to 300 50 to 300 50 to 300Retracted length mm S+160 S+160 S+160 S+160Voltage V DC 24 24 24 24Power consumption W 70 120 70 120Current consumption A 3 5 3 5Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C +10 to +40 +10 to +40 +10 to +40 +10 to +40Type of protection IP 4S 4S 4S 4SWeight kg 2,1 2,1 2,5 2,5Color Black or grey Black or grey Black or grey Black or grey
ECOMAG
S
C
U
1
EHA 1
EHA 3
STJ
STA
STE
S
C
U
5
S
C
U
9
V
C
U
5
V
C
U
8
V
C
U
9
B
C
U
5
B
C
U
8
M
C
U
Hand switch
Foot switch
Desk switch
Control units
3
0
6
+
0
,
7
+
0
,
5
3
0
6
+
0
,
7
+
0
,
5
15
15 15
17
26
26
165
72
113
L = S+160
Dimensional drawing
Connecting diagram
Ecomag 2-3-6-7
Ecomag 4-5-8-9
Rear attachment position
Push version only Push and pull version
3
0
7
2
2
5
2
2
,
4
8
3
,
4
3
0
6
+
0
,
7
+
0
,
5
6
+
0
,
7
+
0
,
5
15 15 15
140 25
17
79
A
L = S+160
Label position
Label position
Legend:S = strokeL = retracted length
450
90
135
450
90
135
2
-
Linear actuators DC versions Ecomag
Performance diagrams
Speed-load diagram Current-load diagram
ECO 20 / 30 / 40 / 50ECO 60 / 70 / 80 / 90
ECO 20 / 30 / 40 / 50ECO 60 / 70 / 80 / 90
Safety factor load conditions
Push load reductionSafety factor=4
00 2 000 4 000 6 000 8 000
2
4
6
8
10
12
14
16
Speed (mm/s)
Load (N)
00 2 000 4 000 6 000 8 000
2
4
6
8
10
12
14
16
Load (N)
Current consumption (A)
4 500
6 000
3 000
1 500
0 100 200 300 400
0
Push load (N)
Stroke length (mm)
3
SKF is a registered trademark of the SKF Group
SKF Group 2011The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5301,2400 EN February 2011
Ecomag
Ordering key
Type
Load /Housing:Push Pull Housing2 000 N 0 Large 22 000 N 2 000 N Large 32 000 N 0 Small 42 000 N 2 000 N Small 56 000 N 0 Large 66 000 N 4 000 N Large 76 000 N 0 Small 86 000 N 4 000 N Small 9
Encoder:No encoder, coiled cable, 2-pin Minifit plug or customization 0No encoder, coiled cable , DIN8 plug or customization 92-Hall encoder, 8 pulses, straight cable, DIN8 plug (small housing only) F
Current cut-off:No 0Yes (not available for ECO4.-/ECO5.-/ECO8.-/ECO9.-) 1
Stroke (S):50 mm 05100 mm 10150 mm 15200 mm 20250 mm 25300 mm 30Other stroke lengths; 50
-
Linear actuatorRunner
BenefitsHigh push/pull loadCompactBack-up nut as standardHigh safety factorSilent operation
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsRunner
Suitable control units and accessories Dimensional drawing
Connecting diagram
Legend:S = strokeL = retracted length
Rear attachment position
Retracted length: * up to 500 mm stroke: stroke +215 mm (plus options) from 500 mm stroke: stroke +315 mm (plus options)
Technical data
Unit RU20 RU21 RU 22 RU23 RU24 RU25
Rated push load N 8 000 10 000 12 0001) 8 000 10 000 12 0001)
Rated pull load N 8 000 8 000 8 000 8 000 8 000 8 000Speed (full load to no load) mm/s 7 to 10 5 to 8 4 to 7 8 to 15 6 to 12 5 to 9Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+215/3152) S+215/3152) S+215/3152) S+215/3152) S+215/3152) S+215/3152)
Voltage V DC 24 24 24 24 24 24Power consumption W N/A N/A N/A N/A N/A N/ACurrent consumption A 7 7 7 10 10 10Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C +10 to +40 +10 to +40 +10 to +40 +10 to +40 +10 to +40 +10 to +40Type of protection IP 4/6S 4/6S 4/6S 4/6S 4/6S 4/6S Weight kg 4,7 4,7 4,7 4,7 4,7 4,7Color Grey Grey Grey Grey Grey Grey
1) Safety working load for medical application is 10 000 N (EN 60601)2) S 500 mm; L = S + 215 S > 500 mm; L = S + 315
3
0
,
7
95
4
7
4 4
9 9
1
1
3
0
45 0
90
135 53
168
1215
2
8
23189
8
0
1
1
1
1
2
8
14 15
L+30
L = S + 215/315* (+-2 mm)
12 +0,3+0,1
12 +0,3+0,1
0
3
5
3
3
3
,
6
Stroke
Stroke
+
24 V DC
M
Black Red
Limit switch
Actuator
RU20, RU21, RU22
S
C
U
1
RU23, RU24, RU25
EHA 3
STJ
S
C
U
5
S
C
U
9
V
C
U
5
V
C
U
8
V
C
U
9
B
C
U
5
B
C
U
8
STE
Control units
Hand switch
Foot switch
Desk switch
2
-
Linear actuators DC versions Runner
Performance diagrams
Safety factor load conditions
Speed-load diagram
Speed-load diagram
Push load limit, safety factor S=4 (EN 60601) 1) retracted length extension at stroke >500 mm
Push load limit, safety factor S=2 1) retracted length extension at stroke >500 mm
Current-load diagram
Current-load diagram
RU 20
RU 21
RU 22
12
8
4
0
2
6
10
14
2 0000 4 000
6 0008 000
10 00012 000
14 000
Load (N)
Speed (mm/s)
RU 23
RU 24
RU 25
12
8
4
0
02 000
2
6
10
14
6 000 10 000120004 000 8 000
14000
16
Load (N)
Speed (mm/s)
RU20RU23
RU24
RU22RU21
RU25
0
0 100 300 500 600200 400 700
1)
14 000
12 000
10 000
8 000
6 000
4 000
2 000
Load (N)
Stroke (mm)
RU20RU23
RU21
RU24
0
0 100 300 500 600200 400 700
1)
RU22RU25
14 000
12 000
10 000
8 000
6 000
4 000
2 000
Load (N)
Stroke (mm)
RU 20
RU 21
RU 22
8
6
4
2
0
1
3
5
7
2 0000 4 000
6 0008 000
10 00012 000
14 00016 000
Load (N)
Current consumption (A)
RU 23
RU 24
RU 25
8
6
4
2
0
02 000
1
3
5
7
6 000 10 00012 0004 000 8 000
14 00016 000
10
Load (N)
Current consumption (A)
3
SKF is a registered trademark of the SKF Group
SKF Group 2011The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2540 EN October 2011
Runner
Ordering key
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Type
Voltage:24 V DC
Load / Speed:8 000 N / 7-10 mm/s 08 000 N / 8-15 mm/s 310 000 N / 5-8 mm/s 110 000 N / 6-12 mm/s 412 000 N / 4-7 mm/s 212 000 N / 5-9 mm/s 5
Stroke (S) / Retracted length (L):50 mm / 315 mm 0 5 0 3 1 5100 mm / 315 mm 1 0 0 3 1 5150 mm / 365 mm 1 5 0 3 6 5200 mm / 415 mm 2 0 0 4 1 5250 mm / 465 mm 2 5 0 4 6 5300 mm / 515 mm 3 0 0 5 1 5350 mm / 565 mm 3 5 0 5 6 5400 mm / 615 mm 4 0 0 6 1 5450 mm / 665 mm 4 5 0 6 6 5500 mm / 715 mm 5 0 0 7 1 5550 mm / 865 mm 5 5 0 8 6 5600 mm / 915 mm 6 0 0 9 1 5650 mm / 965 mm 6 5 0 9 6 5700 mm / 1 015 mm 7 0 0 XXX50
-
Linear actuatorMatrix 1
BenefitsSilent operation
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsMatrix 1
S
15
2
8
2
8
1
1
1
1
1514
12 116
L2*
Suitable control units and accessories Dimensional drawing
S < 350 mm; L = 195 + S* S > 350 mm; L = 260 + S
Technical data
Unit MAX 1..A.. MAX 1..B.. MAX 1..C..
Rated push load N 4 000 2 000 1 500Rated pull load N 4 000 2 000 1 500Speed (full load to no load) mm/s 5 to 7 6 to 9 12,7 to 18Stroke mm 50 to 700 50 to 700 50 to 700Retracted length mm S + 195/260* S + 195/260* S + 195/260*Voltage V DC 24 24 24Power consumption W 120 120 120Current consumption A 5 5 5Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 0 to +40 0 to +40 0 to +40Type of protection IP 66S 66S 66SWeight (at 200 mm stroke) kg 4,0 3,7 3,6Color Grey Grey Grey
Connecting diagram*
Side view
24 V DC+
-
M
5V+
GND
1+7 2+4
1,5K 1,5K
Hall AHall B
3 5 6 8
DIN8 plug
2 Hallsensors signal
Actuator
Blue Red
Top view
Rear view
Only valid for MAX 11. MAX 10 must be operated by a *BCU, MCU, SCU or VCU control unit.
Rear attachment position
12+0,3+0,15 12+0,3+0,1
66
3
1
2
9
DIN8 plug
4
0
1
6
9
107
48
66 Label
MAX 1
S
C
U
1
EHA 1
EHA 3
STJ
STA
STE
S
C
U
5
S
C
U
9
V
C
U
5
V
C
U
8
V
C
U
9
B
C
U
5
B
C
U
8
M
C
U
Hand switch
Foot switch
Desk switch
Control units
S350 mm, L = 260 + S
2
-
Linear actuators DC versions Matrix 1
Performance diagrams
Safety factor load conditions
Speed-load diagram
Push load reduction staticSafety factor S=1
Push load reduction staticSafety factor S=2
Push load reduction static Safety factor S=4 (EN60601)
Current-load diagram
C
B
A
20
15
10
5
0
0 1 000 2 000 3 000 4 000
Speed (mm/s)
Load (N)
7,5
10,0
5,0
2,5
0
0 1 000 2 000 3 000 4 000
B
C
A
Current consumption (A)
Load (N)
6 000
8 000
4 000
2 000
3 000
5 000
7 000
1 000
0
0 200100 300 500 700400 600 800
A
B
C
Stroke (mm)
Load (N)
6 000
8 000
4 000
2 000
3 000
5 000
7 000
1 000
0
0 200100 300 500 700400 600 800
A
B
C
Stroke (mm)
Load (N)
3 000
4 000
2 000
1 000
0
3 500
2 500
1 500
500
0 200 400 600100 300 500 700 800
Load (N)
Stroke (mm)
A pull/push
B pull/push
C pull/push
3
SKF is a registered trademark of the SKF Group
SKF Group 2010The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2510 EN May 2010
Matrix 1
Type
Voltage:24 V DC 024 V DC with integrated current cut-off 1
Load:4 000 N A2 000 N B1 500 N C
Stroke (S):50 mm 050 245100 mm 100 295150 mm 150 345200 mm 200 395250 mm 250 445300 mm 300 495350 mm 350 545400 mm 400 660450 mm 450 710500 mm 500 760550 mm 550 810600 mm 600 860650 mm 650 910700 mm 700 960Other stroke lengths; 50
-
Linear actuatorMatrix 3
BenefitsSilent operationFull system with control unit, operating switch and accessories
Synchronization possibleCompact and aestheticBack-up nut as standard
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsMatrix 3
Suitable control units and accessories
Connecting diagram*
Technical data
Unit MAX 3..A.. MAX 3..B.. MAX 3..C..
Rated push load N 8 000 4 000 3 000Rated pull load N 6 0001) 4 000 3 000Speed (full load to no load) mm/s 5 to 7 6 to 9 12,7 to 18Stroke mm 50 to 700 50 to 700 50 to 700Retracted length mm S + 215/2802) S + 215/2802) S + 215/2802)
Voltage V DC 12 or 24 12 or 24 12 or 24Power consumption W 120 120 120Current consumption A 5,0 5,0 5,0Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 0 to +40 0 to +40 0 to +40Type of protection IP 66S 66S 66SWeight (at 200 mm stroke) kg 4,5 4,2 4,0Color Grey Grey Grey
1) Max load for medical application is 5 000 N2) S 350 mm; L = S + 215 S > 350 mm; L = S + 280
* Only valid for MAX 31. MAX 30 must be operated by aBCU, MCU, SCU or VCU control unit.
MAX 3
S
C
U
1
EHA1
EHA3
STJ
STA
STE
S
C
U
5
S
C
U
9
V
C
U
5
V
C
U
8
V
C
U
9
B
C
U
5
B
C
U
8
M
C
U
Control units
Hand switch
Foot switch
Desk switch
12/24 V DC+
-
M
5V+
GND
1+7 2+4
1,5K 1,5K
Hall AHall B
3 5 6 8
DIN8 plug
2 Hallsensors signal
Actuator
Blue Red
2
8
15 12
1 1
1 1
2
8
1
1
S L 2*
14
136 15
Dimensional drawing
Side view
Top view
Rear view
S < 350 mm; L = S + 215 *S > 350 mm; L = S + 280
12+0,3
+0,1
2
9
82
12+0,3
+0,1
3
1
4
2
,
5
DIN8 plug
82
1
9
2
4
0
50
112
122
Label
Rear attachment positionStandard 0 Turned 90
2
-
Linear actuators DC versions Matrix 3
Performance diagrams
Safety factor load conditions
Speed-load diagram
Push load reduction staticSafety factor S=1
Push load reduction staticSafety factor S=2
Push load reduction staticSafety factor S=4 (EN60601)
Current-load diagram
20
15
10
5
0
0 2 000 4 000 6 000 8 000
C
B
A
Speed (mm/s)
Load (N)
7,5
10,0
5,0
2,5
0
0 2 000 4 000 6 000 8 000
B
CA
Current consumption (A)
Load (N)
6 000
8 000
4 000
2 000
3 000
5 000
7 000
1 000
0
0 200100 300 500 700400 600 800
A
B
C
Stroke (mm)
Load (N)
A
B
C
8 000
2 000
3 000
4 000
1 000
5 000
6 000
7 000
0
0 100 200 300 400 500 600 700 800
Stroke (mm)
Load (N)
6 000
8 000
4 000
2 000
0
1 000
3 000
5 000
7 000
0 200 400 600100 300 500 700 800
Load (N)
Stroke (mm)
A push
C push
A pull
B pull/push
C pull
3
SKF is a registered trademark of the SKF Group
SKF Group 2011The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2520 EN February 2011
Matrix 3
Type
Voltage:24 V DC 024 V DC with integrated current cut-off 112 V DC 2
Load:8 000 N A4 000 N B3 000 N C
Stroke (S):50 mm 050 265100 mm 100 315150 mm 150 365200 mm 200 415250 mm 250 465300 mm 300 515350 mm 350 565400 mm 400 680450 mm 450 730500 mm 500 780550 mm 550 830600 mm 600 880650 mm 650 930700 mm 700 980Other stroke lengths; 50
-
Linear actuatorMatrix 6
B
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMatrix 6
Suitable control units and accessories
Connecting diagram
Technical data
Unit MAX 6..A.. MAX 6..B.. MAX 6..C..
Rated push load N 8 000 4 000 3 000Rated pull load N 6 0001) 4 000 3 000Speed (full load to no load) mm/s 6 to 7,5 8 to 10 13 to 18Stroke mm 50 to 700 50 to 700 50 to 700Retracted length mm S + 215/2802) S + 215/2802) S + 215/2802)
Voltage V AC 120 or 230 120 or 230 120 or 230Power consumption 120 V AC W 150 150 150
230 V AC W 145 145 145Current consumption 120 V AC A 1,8 1,8 1,8
230 V AC A 0,9 0,9 0,9Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 0 to +40 0 to +40 0 to +40Type of protection IP 66S 66S 66SWeight (at 200 mm stroke) kg 4,8 4,5 4,2Color Grey Grey Grey
1) Max load for medical application is 5 000 N2) S < 350 mm; L = S + 215 S > 350 mm; L = S + 280
E
H
A
1
S
T
F
P
A
M
P
H
C
1
P
F
P
S
T
A
Hand switch
Foot switch
Desk switch
MAX 6 Integrated control unit
L
N
M
PE
120/230 V AC
Operatingdevice
Dimensional drawing
Side view
2
8
15 12
136
14
15
1
1
1
1
S L2*
2
8
S < 350 mm; L = S + 215 *S > 350 mm; L = S + 280
Top view
Rear attachment positionStandard 0 Turned 90
85
12+0,3
+0,1
12+0,3
+0,1
4
2
,
5
3
1
2
9
Mains cable
123
135
112
50
4
0
,
5
1
9
2
,
5
Label
2
-
Linear actuators AC versions Matrix 6
Performance diagrams
Safety factor load conditions
Speed-load diagram
Push load reduction staticSafety factor S=1
Push load reduction staticSafety factor S=2
Push load reduction staticSafety factor S=4 (EN60601)
Current-load diagram
Accessories
Description Plug Country Designation Order number
Straight cable 3,5 m Schuko DE ZKA1403063500 M/0121723Straight cable 3,5 m SEV CH ZKA1403163500 M/0121737Straight cable 3,5 m UL USA ZKA1403553500 M/0121724Straight cable 3,5 m Hospital grade USA ZKA1403603500 M/0121732Straight cable 3,5 m British standard UK ZKA1403503500 M/0121743Coiled cable 1,2 m / 2,2 m Schuko DE ZKA1403421500 M/0121728Coiled cable 1,2 m / 2,2 m SEV CH ZKA1403781200 M/0121738Straight polyurethane cable 3,5 m SEV CH ZKA1404223500 M/0121739Straight polyurethane cable 3,5 m Schuko DE ZKA1404263500 M/0121740 Strain relief for mains cable ZUB952253 M/0102848Tool for plugs (Jack/DSub/Mains) ZWS140375 M/0125322
C
B
A
20
15
10
5
0
0 2 000 4 000 6 000 8 000
Speed (mm/s)
Load (N)
1,5
2,0
C (120 V)
B (120 V)
B (230 V)
A (230 V)
C (230 V)A (120 V)
1,0
0,5
0
0 2 000 4 000 6 000 8 000
Current consumption (A)
Load (N)
6 000
8 000
4 000
2 000
3 000
5 000
7 000
1 000
0
0 200100 300 500 700400 600 800
A
B
C
Load (N)
Stroke (mm)
A
B
C
8 000
2 000
3 000
4 000
1 000
5 000
6 000
7 000
0
0 100 200 300 400 500 600 700 800
Load (N)
Stroke (mm)
6 000
8 000
4 000
2 000
0
1 000
3 000
5 000
7 000
0 200 400 600100 300 500 700 800
Load (N)
Stroke (mm)
A push
C push
A pull
B pull/push
C pull
3
SKF is a registered trademark of the SKF Group
SKF Group 2011The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2532 EN February 2011
Matrix 6
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Ordering key
Type
Voltage:230 V AC/50 Hz, integrated pneumatic control 0120 V AC/60 Hz, integrated pneumatic control 1230 V AC/50 Hz, integrated low voltage control with additional 24 V output 2120 V AC/60 Hz, control +1 channel with additional 24 V output 3230 V AC/50 Hz, integrated low voltage 4120 V AC/60 Hz, integrated low voltage 5
Load:8 000 N A4 000 N B3 000 N C
Stroke (S):50 mm 050 265100 mm 100 315150 mm 150 365200 mm 200 415250 mm 250 465300 mm 300 515350 mm 350 565400 mm 400 680450 mm 450 730500 mm 500 780550 mm 550 830600 mm 600 880650 mm 650 930700 mm 700 980Other stroke lengths; 50
-
Linear actuatorMagdrive
BenefitsSlim designAluminium profileIn-line actuatorQuiet operationHigh push load
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsMagdrive
Suitable control units and accessories Dimensional drawing
Legend:S = strokeL = retracted length
MAGDRIVE
S
C
U
1
EHA 3
STJ
STE
S
C
U
5
S
C
U
9
V
C
U
5
V
C
U
8
V
C
U
9
B
C
U
5
B
C
U
8
Technical data
Unit MD22/MD24 MD23/MD25
Push load N 6 000 6 000Pull load N 200* (static only) 6 000Speed (full load to no load) mm/s 8,5 to 15 8,5 to 15Stroke mm 50 to 700 50 to 700Retracted length mm S+465 S+489Voltage V DC 24 24Power consumption W N/A N/ACurrent consumption A 7 7Duty cycle % 10 (1/9) 10 (1/9)Ambient temperature C +10 to +40 +10 to +40Type of protection IP 0/4S 0/4SWeight kg 5,0 5,0Color Colorless anodized Colorless anodized
Connecting diagram
+24 V DC
M
62
15 12
2
8
1
1
12+0,3+0,1 12
+0,3+0,1
3
1
L = S + 465/4892
L= 1 500 mm
2
9
2
8
151527
1
1
Plastic bushing for forkhead (hinge delivered separately)
Orientation of rear attachment
2510
2
6
8,7
10
12
90 turnedStandard 0
2
-
Linear actuators DC versions Magdrive
Performance diagrams
Safety factor load conditions
Speed-load diagram
Pull load diagram MD25 (6 000 N)Safety factor according UL606011, IEC606011
Current-load diagram
Push load diagram Safety factor S=2 Safety factor according UL606011, IEC606011 Safety factor according UL606011, IEC606011
Pull load diagram MD23 Safety factor S=4 Safety factor according UL606011, IEC606011
0 2 000 4 000 6 000
0
2
4
6
8
10
12
14
16
1 000 3 000 5 000 7 000 8 000
Speed (mm/s)
Load (N)
0 2 000 4 000 6 0001 000 3 000 5 000 7 000 8 000
0
1
2
3
4
5
6
7
8
Current consumtion (A)
Load (N)
0 200 400 600
0
100 300 500 700 800
8 000
6 000
4 000
2 000
1 000
3 000
5 000
7 000
MD 22-25
MD 24/25
MD 22/23
Load (N)
Stroke (mm)
0 200 400 600
0
100 300 500 700 800
8 000
6 000
4 000
2 000
1 000
3 000
5 000
7 000
Load (N)
Stroke (mm)
0 200 400 600
0
100 300 500 700 800
8 000
6 000
4 000
2 000
1 000
3 000
5 000
7 000
Load (N)
Stroke (mm)
3
SKF is a registered trademark of the SKF Group
SKF Group 2011The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2590 EN February 2011
Magdrive
Ordering key
Type
Push/pull force:6 000 N/200 N 26 000 N/6 000 N 36 000 N/200 N (recommended formedical applications- with alu. rear hinge) 46 000 N/6 000 N (recommended formedical applications- with alu. rear hinge) 5
Stroke:50 mm 050100 mm 100150 mm 150200 mm 200250 mm 250300 mm 300350 mm 350400 mm 400450 mm 450500 mm 500550 mm 550600 mm 600650 mm 650700 mm 700Other stroke lengths _ _ _
Retracted length:MD22/24: S+465 mm _ _ _MD23/25: S+489 mm _ _ _Over 1 000 mm assembly length, use customer specific adaption X X XOthers _ _ _
Type of protection:IPX0 AIPX4S B
Motor cable:Straight, 1,5 m, DIN8 plug 15Straight, 1,5m, jack plug 180 0D
Rear attachment / Hole diameter:Standard 0 / 12 mm 0Rotated 90 / 12 mm 4
Option 1:No option 0Electrical anti-pinching protection, safety switch, motor direction push LElectrical anti-pinching protection, safety switch, motor direction pull K
Option 2:No option 0Dual encoder (only available with DIN8 plug) 2,15 impulse per turn/sensor (= 5,375 imp. per 1 mm.) F
Option 3:No option Emergency lowering fork head bore (add 30 mm to retracted length "L") V
M D 2 0 0
Options written in italic fonts are only available on demand. Please contact SKF.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce WSP
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce WSP
Dimensional drawingConnecting diagram
LNPE
230 V AC
M
Technical data
Unit WSP 0510 WSP 1030 WSP 1550 WSP 2650
Push load N 500 1 000 1 5001) 2 6002)
Pull load N 500 1 000 1 500 2 600Speed (at full load) mm/s 50 18 10 5Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+230 S+230 S+230 S+230Voltage V AC 230 230 230 230Power consumption W 230 200 200 230Current consumption A 1,1 1 1 1,1Duty cycle % 25 (2,5/7,5) 25 (2,5/7,5) 25 (2,5/7,5) 25 (2,5/7,5)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 5,5 5,5 5,5 5,5Color Silver Silver Silver Silver
Side view
1)Push load allowed up to 650 mm stroke (if S>650 mm, only pull load is allowed)2)Push load allowed up to 500 mm stroke (if S>500 mm, only pull load is allowed)
Stroke
122
3
0
90
72
120
48
127
31
108
90
1
6
1
1
9
9
2
2
8
5
6
44
1
2
+
0
,
0
9
+
0
,
0
4
10 H8
10
2
0
3
0
60
72,5
25
1
0
H
1
1
1
6
4 10
Top view
Rear view
Free-wheel-brake on request
Retracted length = stroke + 230 mm
Stroke + 255
PG clamp range
2
-
Linear actuators AC versions Magforce WSP
Performance diagram Safety load factor conditions
Bending of spindle S = safety factor Euler 3
Speed-load diagram
Options
WSP 0510-200WSP 1030-200WSP 1550-200WSP 2650-200
31
2
0
1
5
12
11
Extended motor shaft Rear screw fixing
0
10
20
30
40
50
60
0 500 1 000 1 500 2 000 2 500 3 000
Speed (mm/s)
Load (N)
0
F
1 2 3 4 5 6 7 8
800
700
600
500
400
300
200
100
S = 4
Load (kN)
Stroke (mm)
Add. guidingrecommended
Standardguiding
25
4 holes threadM 6 9 mm deep
Retracted length = stroke + 203 mm
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2110 EN April 2012
Magforce WSP
Spare parts
Description Designation Order N
Limit switch 100 mm stroke 1043,0209100 M/0126964Limit switch 200 mm stroke 1043,0209200 M/0126965Limit switch 300 mm stroke 1043,0209300 M/0126966Limit switch 400 mm stroke 1043,0209400 M/0126967Limit switch 500 mm stroke 1043,0209500 M/0126968Limit switch 600 mm stroke 1043,0209600 M/0126969
Ordering key
Type
Load:500 N 05101 000 N 10301 500 N 15502 600 N 2650
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Free wheel brake on push load, 1028, 6228 AFree wheel brake on pull load, 1028, 0002 BFriction brake for pull/push load, 1028, 7851 C
Option 3:No option 0Limit switch 1
W S P
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.Example for ordering an actuator without any options: WSP103010001.Example for ordering an actuator with option limit switch: WSP10301000101 (01= with limit switch). * Example for others XX: Add. guiding bush - L=S+280 mm, protection tube made out of stainless steel, bronze nut, low temp grease 30, extended motorshaft, rear attachment hole turned 90, without rear attachment; motor turned 90.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce DSP
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce DSP
K2
K2
K1
K1
L1L2L3NPE
3x400 V AC
K1
K2
M3
Dimensional drawingConnecting diagram
Technical data
Unit DSP 1010 DSP 2530 DSP 3250 DSP 4550
Push load N 1 000 2 5001) 3 2002) 4 5003)
Pull load N 1 000 2 500 3 200 4 500Speed (at full load) mm/s 50 15 10 5Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+230 S+230 S+230 S+230Voltage V AC 3400 3400 3400 3400Power consumption W 210 260 260 280Current consumption A 0,5 0,6 0,6 0,6Duty cycle % 40 (4/6) 40 (4/6) 40 (4/6) 40 (4/6)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 5,6 5,6 5,6 5,6Color Silver Silver Silver Silver
1)Push load allowed up to 500 mm stroke (if S>500 mm, only pull load is allowed)2)Push load allowed up to 450 mm stroke (if S>450 mm, only pull load is allowed)3)Push load allowed up to 350 mm stroke (if S>350 mm, only pull load is allowed)
10H8
127
90
44
25
72
72,5
120
5
6
3
0
1
0
H
1
1
2
0
1
6
3
0
10
108
1
5
2
1
9
0
2
1
9
90
48
1
2
+
0
,
0
9
+
0
,
0
4
Side view
Top view
Rear view
Free-wheel-brake on request
Retracted length = stroke + 230 mm
Stroke + 255Stroke
2
-
Linear actuators AC versions Magforce DSP
Performance diagram Safety load factor conditions
Bending of spindle S = safety factor Euler 3
Speed-load diagram
Options
DSP 1010-200DSP 2530-200DSP 3250-200DSP 4550-200
31
2
0
11
1
5
12
Extended motor shaft Rear screw fixing
0
10
20
30
40
50
60
0 1 000 2 000 3 000 4 000 5 000
Speed (mm/s)
Load (N)
0
10 2 3 4 5 6 7 8
F
800
700
600
500
400
300
200
100
S = 4
Stroke /mm)
Load (kN)
Add. guidingrecommended
Standardguiding
25
Retracted length = stroke + 203 mm
4
h
o
l
e
s
t
h
r
e
a
d
M
6
9
m
m
d
e
e
p
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2120 EN April 2012
Magforce DSP
Spare parts
Designation Order N
Limit switch 100 mm stroke ZAC1043,02100100 M/0126970Limit switch 200 mm stroke ZAC1043,02100200 M/0126971Limit switch 300 mm stroke ZAC1043,02100300 M/0126972Limit switch 400 mm stroke ZAC1043,02100400 M/0126973Limit switch 500 mm stroke ZAC1043,02100500 M/0126974Limit switch 600 mm stroke ZAC1043,02100600 M/0126975
Ordering key
Type
Load:1 000 N 10102 500 N 25303 200 N 32504 500 N 4550
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Free wheel brake on push load, 1028, 6226 AFree wheel brake on pull load, 1028, 0002 BFriction brake for pull/push load, 1028, 7851 C
Option 3:No option 0Limit switch 1
D S P
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.Example for ordering an actuator without any options: DSP101010001.Example for ordering an actuator with option limit switch: DSP10101000101 (01= with limit switch). * Example for others XX: Add. guiding bush - L=S+280 mm, protection tube made out of stainless steel, bronze nut, low temp grease -30, extended motorshaft, rear attachment hole turned 90, without rear attachment; motor turned 90.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce ASM
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsMagforce ASM
Dimensional drawingConnecting diagram
Legend:S = strokeL = retracted length
12/24 V DC
ASM
+
M
Technical data
Unit ASM 1010 ASM 2030 ASM 3030 ASM 4050
Push load N 1 000 2 0001) 3 0002) 4 0003)
Pull load N 1 000 2 000 3 000 4 000Speed (at full load) 12 V DC mm/s 50 17 8 5
24 V DC mm/s 45 18 8 5Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+230 S+230 S+230 S+230Voltage V DC 12 or 24 12 or 24 12 or 24 12 or 24Power consumption 12 V DC W 192 168 168 168
24 V DC W 192 144 168 168Current consumption 12 V DC A 16 14 14 14
24 V DC A 8 6 7 7Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 44 44 44 44Weight kg 5 5 5 5Color Silver Silver Silver Silver
1)Push load allowed up to 600 mm stroke (if S>600 mm, only pull load is allowed)2)Push load allowed up to 450 mm stroke (if S>450 mm, only pull load is allowed)3)Push load allowed up to 400 mm stroke (if S>400 mm, only pull load is allowed)
Side view
Top view
Rear view
2 x 1,5 mm2 x 500 mm
10 H8
80
5
6
78
72
72,5
25
44
120
10
3
0
2
0
1
0
H
1
1
1
6
3
0
+
0
,
0
9
+
0
,
0
4
1
2
103
31
48
2
2
5
2
0
3
1
6
5
Free-wheel-brake on request
Retracted length = stroke + 230 mm
Stroke + 255Stroke
2
-
Linear actuators DC versions Magforce ASM
Performance diagrams
Safety factor load conditions
Speed-load diagram at 12 V DC
Bending of spindle S = safety factor Euler 3
Speed-load diagram at 24 V DC
ASM 1010ASM 2030ASM 3030ASM 4050
0
1 2 3 4 5 6 7 8
F
800
700
600
500
400
300
200
100
S = 4
Stroke (mm)
Add. guidingrecommended
Standardguiding
Load (kN)
0 1 000 2 000 3 000 4 000
80
70
60
50
40
30
20
10
Speed (mm/s)
Load (N)
0 1 000 2 000 3 000 4 000
80
70
60
50
40
30
20
10
Speed (mm/s)
Load (N)
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2130 EN April 2012
Magforce ASM
Spare parts
Designation Order N
Limit switch 100 mm stroke ZAC1043,02100100 M/0126970Limit switch 200 mm stroke ZAC1043,02100200 M/0126971Limit switch 300 mm stroke ZAC1043,02100300 M/0126972Limit switch 400 mm stroke ZAC1043,02100400 M/0126973Limit switch 500 mm stroke ZAC1043,02100500 M/0126974Limit switch 600 mm stroke ZAC1043,02100600 M/0126975
Ordering key
Type
Load:1 000 N 10102 000 N 20303 000 N 30304 000 N 4050
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:12 V DC 0124 V DC 02Others* XX
Option 2:No option 0Free wheel brake on push load, 1028,6226 AFree wheel brake on pull load, 1028, 0002 BFriction brake for pull/push load, 1028, 7851 C
Option 3:No option 0Limit switch 1
A S M
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.Example for ordering an actuator without any options: ASM101010001.Example for ordering an actuator with option limit switch: ASM10101000101 (01= with limit switch). * Example for others XX: Add. guiding bush - L=S+280 mm, protection tube made out of stainless steel, bronze nut, low temp grease 30, extended motorshaft, rear attachment hole turned 90, without rear attachment; motor turned 90.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce STW
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce STW
Dimensional drawing
Connecting diagrams
230 V ACL1N
M
PE
K2
K1
C
W V U
Y X Z
2
230 V AC
L1N
M
PE
K2
K1
C
W V U
Y X Z
K2
K1
1 3 54 6
K1
K2
Technical data
Unit STW 5007 STW 7010 STW 10020 STW 15040
Push load N 5 000 7 000 10 000 15 000Pull load N 5 000 7 000 10 000 15 000Speed (at full load) mm/s 12 8 4 2Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+273 S+273 S+273 S+273Voltage V AC 230 230 230 230Power consumption W 700 710 710 750Current consumption A 3,3 3,5 3,5 3,5Duty cycle % 15 (1,5/8,5) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 14,6 14,6 14,6 14,6Color Silver Silver Silver Silver
With optional limit switch
116
4
0
174
6
5
M
3
2
x
1
,
5
54 56
2
0
16F7
116
140
35
20
95
31
67
7
9
6
9
Side view
Top view
Rear view
Limit switches or potentiometer on request
PG 16 clamp-range 815
Retracted length = stroke + 273
Stroke + 293Stroke
2
-
Linear actuators AC versions Magforce STW
STW 5007-200STW 7010-200STW 10020-200STW 15040-200
Performance diagram Safety load factor conditions
Bending of spindle S = safety factor Euler 3
Options
82
M
1
8
x
2
,
5
M
3
2
x
2
,
5
4
0
2517
40 SW 30
Adapter Front attachment
Speed-load diagram
0
2
4
6
8
10
12
14
0 5 000 10 000 15 000
Speed (mm/s)
Load (N)
800
700
600
500
400
300
100
200
0
0 2 4 6 10 14 16 188
S = 4F
Stroke (mm)
Add. bearingrecommended
Standard guiding
Load (kN)
Stroke + 290Stroke
9
1
8
9
22
18
36SW 27
SW 30
3
6
Stroke + 377
Stroke + 419
Stroke
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2310 EN April 2012
Magforce STW
Spare parts
Designation Order N
Adapter bolt ZBE1031,0106 M/0125265Fork head ZBE1051,9038 M/0124705
Ordering key
Type
Load:5 000 N 050077 000 N 0701010 000 N 1002015 000 N 15040
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Adapterbolt M18 1031,0106 EFork head (including adapterbolt) 1051,9038 F
Option 3:No option 0Limit switch 1Potentiometer (1 000 ) 2Encoder 1063,0020 3
S T W
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.Example for ordering an actuator without any options: STW0500710001.Example for ordering an actuator with option fork head: STW0500710001F0 (F0= with fork head). * Example for others XX: Back up nut, extended motor shaft, low temperature grease...
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce STD
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce STD
Dimensional drawing
Connecting diagrams
3x400 V AC
L1L2L3N
M
PE
K1
K2
1 3 2
75
8
6 9 4
K1
K2
K2K1
Technical data
Unit STD 10007 STD 12010 STD 15020 STD 15040
Rated push load N 10 000 12 000 15 000 15 000Rated pull load N 10 000 12 000 15 000 15 000Speed (at full load) mm/s 10 7 4 2Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+273 S+273 S+273 S+273Voltage V AC 3400 3400 3400 3400Power consumption W 920 800 700 500Current consumption A 1,8 1,7 1,6 1,4Duty cycle % 25 (2,5/7,5) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 14,6 14,6 14,6 14,6Color Silver Silver Silver Silver
With optional limit switch
M
3
2
x
1
,
5
116 5654
174 16 F7
4
0
6
5
31
2
0
116
140
35
7
5
6
9
95 67
20
Retracted length = stroke + 273
Stroke + 293Stroke
PG 16 clamp-range 815
Side view
Top view
Rear view
Limit switches or potentiometer on request
3x400 V AC
L1L2L3N
M
PE
K1
K2
1 3 2
75
8
6 9 4
2
K2
1 3 54 6
K1
K1 K2
Limit switch
2
-
Linear actuators AC versions Magforce STD
Performance diagram Safety load factor conditions
Bending of spindle S = safety factor Euler 3
Options
STD 10007-200STD 12010-200STD 15020-200STD 15040-200
Adapter Fork head
Speed-load diagram
40 SW 30
82
2517
M
1
8
x
2
,
5
M
3
2
x
1
,
5
4
0
Stroke Stroke + 290
22 36SW 27
SW 3018
3
6
9
1
8
9
Stroke + 377Stroke
Stroke + 419
0
2
4
6
8
10
12
14
0 5 000 10 000 15 000
Speed (mm/s)
Load (N)
800
700
600
500
400
300
100
200
0
0 2 4 6 8 10 12 14 16
S = 4F
Stroke (mm)
Add. bearingrecommended
Standard guiding
Load (kN)
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2320 EN April 2012
Magforce STD
Spare parts
Designation Order N
Adapter bolt ZBE1031,0106 M/0125265Fork head ZBE1051,9038 M/0124705
Ordering key
Type
Load:10 000 N 1000712 000 N 1201015 000 N / 4 mm/s 1502015 000 N / 2 mm/s 15040
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Adapterbolt M18 1031,0106 EFork head (including adapterbolt) 1051,9038 F
Option 3:No option 0Limit switch 1Potentiometer (1 000 ) 2Encoder 1063,0020 3
S T D
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.Example for ordering an actuator without any options: STD1000710001.Example for ordering an actuator with option fork head: STD1000710001F0 (F0=with fork head).* Example for others XX: Back up nut, extended motor shaft, low temperature grease, add. guiding bush...
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce STG
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsMagforce STG
Dimensional drawing
Technical data
Unit STG 10007 STG 12010 STG 15020 STG 15040
Rated push load N 10 000 12 000 15 000 15 000Rated pull load N 10 000 12 000 15 000 15 000Speed (at full load) mm/s 14 11 5 3Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+273 S+273 S+273 S+273Voltage V DC 24 24 24 24Power consumption W 840 840 768 528Current consumption A 35 35 32 22Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 14,6 14,6 14,6 14,6Color Silver Silver Silver Silver
Side view
Connecting diagrams
With optional limit switch
24
K1
K2
M
+-
V DC
Brown Blue
2
K2
1 3 54 6
K1
24
K1
K2
M
+-
V DC
K1 K2
Brown Blue
Limit switch
113 61
4
0
173
31
6
5
M
3
2
x
1
,
5
2
0
16 F7
113
140
35
95 67
7
5
6
9
Top view
Rear viewLimit switches or potentiometer on request
Retracted length = stroke + 273
Stroke + 293
Cable length max. 500 mm
Cable length max. 500 mm
Stroke Free-wheel-brake on request
2
-
Linear actuators DC versions Magforce STG
Performance diagram
Safety load factor conditions
Bending of spindle S = safety factor Euler 3
Speed-load diagram
Options
STG 10007300STG 12010300STG 15020300STG 15040300
Adapter Fork head
0
2
4
6
8
10
14
16
18
12
20
0 5 000 10 000 15 000
Speed (mm/s)
Load (N)
800
700
600
500
400
300
100
200
0
0 2 4 6 8 10 12 14 16
S = 4F
Stroke (mm)
Add. guidingrecommended
Standard guiding
Load (kN)
40 SW 30
82
2517
M
1
8
x
2
,
5
M
3
2
x
1
,
5
Stroke + 290Stroke
22 36SW 27
SW 3018
3
6
9
1
8
9
Stroke + 419
Stroke + 377Stroke
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB L5321,2330 EN April 2012
Magforce STG
Spare parts
Designation Order N
Adapter bolt ZBE1031,0106 M/0125265Fork head ZBE1051,9038 M/0124705
Ordering key
Type
Load:10 000 N 1000712 000 N 1201015 000 N / 5 mm/s 1502015 000 N / 3 mm/s 15040
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Adapterbolt M18 1031,0106 EFork head (including adapterbolt) 1051,9038 FMagnetic brake (1,4 Nm) 1031, 0219 G
Option 3:No option 0Limit switch 1Potentiometer (1 000 ) 2Encoder 1063,0020 3
S T G
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative. Example for ordering an actuator without any options: STG1000710001.Example for ordering an actuator with option fork head: STG1000710001F0 (F0= with fork head). *Example for others XX: Back up nut, extended motor shaft, low temperature grease...
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce SKD
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce SKD
Dimensional drawing
Legend:S = strokeL = retracted length
Technical data
Unit SKD 10007 SKD 12010 SKD 15020 SKD 15040
Rated push load N 10 000 12 000 15 000 15 000Rated pull load N 10 000 12 000 15 000 15 000Speed (at full load) mm/s 25 18 11 5Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+406 S+406 S+406 S+406Voltage V AC 3400 3400 3400 3400Power consumption W 920 800 750 600Current consumption A 1,8 1,7 1,6 1,5Duty cycle % 25 (2,5/7,25) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 14,6 14,6 14,6 14,6Color Silver Silver Silver Silver
Side view Rear view
2
1
9
L = S + 406 2
L = S + 309 2
16F7
25
6
5
174
170
114,5
4
0
16
4
2
4
0
130
6
2
6
9
95
140
Limit switch or potentiometer
Connecting diagrams
3x400 V AC
L1L2L3N
M
PE
K1
K2
1 3 2
75
8
6 9 4
K1
K2
K2K1
With optional limit switch
3x400 V AC
L1L2L3N
M
PE
K1
K2
1 3 2
75
8
6 9 4
2
K2
1 3 54 6
K1
K1 K2
Limit switch
2
-
Linear actuators AC versions Magforce SKD
Performance diagram
SKD 10007200SKD 12010200SKD 15020200SKD 15040200
Speed-load diagram
0
5
10
15
20
30
25
35
0 5 000 10 000 15 000
Speed (mm/s)
Load (N)
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10391 EN April 2012
Magforce SKD
Ordering key
S K D
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For options 2 and 3, please contact your SKF representative.Example for ordering an actuator without any options: SKD1000710001.Example for ordering an actuator with option limit switch: SKD100071000101 (01=limit switch).* Example for others XX: Extended motor shaft,...
Type
Load:10 000 N 1000712 000 N 1201015 000 N / 11 mm/s 1502015 000 N / 5 mm/s 15040
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Magnetic brake (1,4 Nm) 1031,0219 G
Option 3:No option 0Limit switch 1Potentiometer (1 000 ) 2Encoder 1063,0020 3
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce SKG
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsMagforce SKG
Connecting diagrams
With optional limit switch
Dimensional drawing
Legend:S = strokeL = retracted length
Technical data
Unit SKG 6005 SKG 10010 SKG 13020 SKG 15040
Rated push load N 6 000 10 000 13 000 15 000Rated pull load N 6 000 10 000 13 000 15 000Speed (at full load) mm/s 55 27 15 8Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+406 S+406 S+406 S+406Voltage V DC 24 24 24 24Power consumption W N/A 720 672 Current consumption A N/A 30 28 Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 14,6 14,6 14,6 14,6Color Silver Silver Silver Silver
Side view
110
140
35
95
16 16 F7
4
0
6
5
174
L=S+406 2
L=S+309 2
25
4
2
4
0
N
7
5
2
2
0
Cable length max. 500 mm
Rear view
24
K1
K2
M
+-
V DC
Brown Blue
2
K2
1 3 54 6
K1
24
K1
K2
M
+-
V DC
K1 K2
Brown Blue
Limit switch
2
-
Linear actuators DC versions Magforce SKG
Performance diagram
SKG 6005200SKG 10010200SKG 13020200SKG 15040200Speed-load diagram
0
10
20
30
40
60
50
70
80
0 5 000 10 000 15 000
Load (N)
Speed (mm/s)
3
SKF is a registered trademark of the SKF Group
SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10392 EN April 2012
Magforce SKG
Ordering key
Type
Load:6 000 N 0600510 000 N 1001013 000 N 1302015 000 N 15040
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Option 1:No option 01Others* XX
Option 2:No option 0Magnetic brake (1,4 Nm) 1031, 0219 G
Option 3:No option 0Limit switch 1Potentiometer (1 000 ) 2Encoder 1063,0020 3
S K G
Options shown in italics are only available on request.
Minimum quantities or additional costs apply for option 1 if shown in italics. For option 2 and 3 please contact your SKF representative.Example for ordering an actuator without any options: SKG0600510001.Example for ordering an actuator with option limit switch: SKG060051000101 (01=limit switch).* Example for others XX: Extended motor shaft,...
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce SKS/SKA
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce SKS/SKA
K2 K1
K1 K2
S2 S1
L13x400 V AC
N
F1PE
L3L2
K2
V1W1 U1
K1
F2
M AC+ -
up down
Dimensional drawingConnecting diagram
Technical data
Unit SKS/SKA 15404 SKS/SKA 20406 SKS/SKA 25412 SKS/SKA 30423
Rated push load N 15 000 20 000 25 000 30 000Rated pull load N 15 000 20 000 25 000 30 000Speed (at full load) mm/s 45 35 17 9Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+465 S+465 S+465 S+465Voltage V AC 3400 3400 3400 3400Power consumption W 1 700 1 650 1 300 1 200Current consumption A 3,3 3,5 2,8 3,0Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54Weight (at 200 mm stroke) kg 30 30 30 30Color Silver Silver Silver Silver
Side view
Top view
203
145
61,5
91
3
0
1
7
5
9
0
210
8
5
3
0
2
6
0
25
25 F8
8
5
6
0
3
1
2
2
Retracted length = stroke + 465
Stroke + 525Stroke
PG 16 clamp-range 815
2
-
Linear actuators AC versions Magforce SKS/SKA
Performance diagram
SKS 15404-300SKS 20406-300SKS 25412-300SKS 30423-300
Speed-load diagram
0
10
30
40
50
20
60
0 5 000 10 000 20 00015 000 30 00025 000
Speed (mm/s)
Load (N)
3
SKF is a registered trademark of the SKF Group
SKF Group 2010The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5321,2380 EN May 2010
Magforce SKS/SKA
Type
Option:No option S
Load:15 000 N 1540420 000 N 2040625 000 N 2541230 000 N 30423
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Customer option:Standard 01Others (extended motor shaft, back-up nut, ...) XX
Type
Option:With limit switches and/or potentiometer A
Load:15 000 N 1540420 000 N 2040625 000 N 2541230 000 N 30423
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Customer option:Standard with limit switch and potentiometer 1k-ohm 01Standard with limit switch 02Others (extended motor shaft, back-up nut, ...) XX
S K S
S K A
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Ordering key
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorMagforce SLS
BenefitsModular RobustReliableHigh speed and/or high loadAll metal design
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators AC versionsMagforce SLS
Dimensional drawingConnecting diagram
Technical data
Unit SLS 18006 SLS 34013 SLS 50020 SLS 50028 SLS 50050
Rated push load N 18 000 34 000 50 000 50 000 50 000Rated pull load N 18 000 34 000 50 000 50 000 50 000Speed (at full load) mm/s 74 36 23 16 9Stroke mm 100 to 700 100 to 700 100 to 700 100 to 700 100 to 700Retracted length mm S+446 S+446 S+446 S+446 S+446Voltage V AC 3400 3400 3400 3400 3400Power consumption W 3 000 3 000 3 000 2 200 1 900Current consumption A 3,9 3,9 3,9 3,5 3,6Duty cycle % 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9) 10 (1/9)Ambient temperature C 10 to +40 10 to +40 10 to +40 10 to +40 10 to +40Type of protection IP 54 54 54 54 54Weight kg 40 40 40 40 40Color Silver Silver Silver Silver Silver
Side view
K2 K1
K1 K2
S2 S1
L13x400 V AC
N
F1PE
L3L2
K2
V1W1 U1
K1
F2
M AC+ -
up down
191
60 45
8
0
1
0
0
3
0
3
0
8
0
1
1
0
200
3
8
1
3
0
8
157
2
5
6
2
90228
65
238
Stroke + 364 / +2
Stroke + 446 / +2
Top view
Rear view
2
-
Linear actuators AC versions Magforce SLS
Performance diagram
SLS 18006SLS 34013SLS 50020SLS 50028SLS 50050
Speed-load diagram
0
10
20
30
40
50
60
70
80
90
100
0 10 000 20 000 30 000 40 000 50 000
Speed (mm/s)
Load (N)
3
SKF is a registered trademark of the SKF Group
SKF Group 2010The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10393 EN May 2010
Magforce SLS
Type
Load:18 000 N 1800634 000 N 3401350 000 N / 23 mm/s 5002050 000 N / 16 mm/s 5002850 000 N / 9 mm/s 50050
Stroke (S):100 mm 100200 mm 200300 mm 300400 mm 400500 mm 500600 mm 600700 mm 700
Customer option:Standard 01Others (extended motor shaft, ...) XX
Ordering key
S L S
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorCARE 33
BenefitsSilent operationMultiple speed/load variantsEasy to adjust limit switchesDifferent attachment optionsDigital encoder feedback
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsCARE 33
Suitable control units and accessories Dimensional drawing
Connecting diagram
Legend:S = strokeL = retracted length
Rearattachmentorientation view.
C
A
E
D
5
-
2
4
R
8dcigdajc^ih
B
C
U
8
B
C
U
5
V
C
U
9
V
C
U
8
V
C
U
5
CAES 31C
EHA 3
STJ
STE
CARE 33A 24V
CARE 33M 24V
CARE 33H 24V
C
A
X
C
3
3
1
)
A^b^ihl^iX]
;ZZY"WVX`
D
u
a
l
e
n
c
o
d
e
r
2
)
=VcYhl^iX];ddihl^iX]9Zh`hl^iX]
Limitswitch
+12/24 V DC
M
1 2
2
13 2
13
Limitswitch
Technical data
Unit CARE 33A CARE 33M CARE 33H
Push load N 2 000 1 400 800Pull load N 2 000 1 400 800Speed (full load to no load) mm/s 8 to 121) 16 to 221) 32 to 451)
Stroke mm 50 to 300 50 to 500 50 to 500Retracted length mm S+150/162/1932) S+150/162/1932) S+150/162/1932)
Voltage V DC 24 24 24Power consumption W N/A N/A N/ACurrent consumption A 3,5 3,5 3,5Duty cycle % 15 20 30Ambient temperature C 10 to +50 10 to +50 10 to +50Type of protection IP 44/65 44/65 44/65Weight kg 1,5 to 2,0 1,5 to 2,0 1,5 to 2,0Color Black Black Black
33 59
26
13
54
64
50
12
L=S+ (150/162/193)*
2
2
3
3
3
3
1
4
0
2
5
8
,
2
2
0
L=S+193
6
,
1
13
11
E 12,7
2
2
L=S+150
10
L=S+162
2
6
38
M
1
2
Dimension depends on selected front attachment*
1) Depending on selected motor2) Dimension depends on selected front attachment
1)See page 3942)See page 397
2
-
Linear actuators DC versions CARE 33
Performance diagrams
Speed-load diagram Current-load diagram
V (mm/s)
V (mm/s)
V (mm/s)
I (A)
A
M
H
0
0
5
50
200 400 600 800 1 000 1 200 1 400 1 600 1 800 2 000
10
15
20
25
30
35
40
45
Speed (mm/s)
Load (N)
0
0
5,0
200
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
400 600 800 1 000 1 200 1 400 1 600 1 800 2 000
Current consumption (A)
Load (N)
3
SKF is a registered trademark of the SKF Group
SKF Group 2009The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10375 EN November 2009
CARE 33
Ordering key
Type
Load:2 000 N A1 400 N M800 N H
Stroke (S):50 mm 050100 mm 100150 mm 150200 mm 200300 mm 300400 mm (not possible for CARE 33A) 400500 mm (not possible for CARE 33A) 500Other stroke lengths ---
Front attachment:Hole, =12,0 mm 1Hole, =12,7 mm 2Hole 10 mm, slot 6,1 mm (retracted length, L=S+162 mm) 3Male thread M12 (retracted length, L=S+193 mm) 4
Rear attachment:Hole, =12,0 mm 1Hole, =12,7 mm 2Hole, =8,0 mm 3Hole, =10,0 mm 4
Type of protection:IP65 1IP44 2
Feedback:No option 0Dual encoder 1
Cable/Connection plug:Straight, 2,0 m, no plug 1Coiled, 2,0 m, jack plug 2Straight, 2,0 m, DIN 8 plug (for 2-channel encoder) 3Straight, 2,0 m, jack plug 5Straight, 2,5 m, DIN8 plug BCU/VCU (ONLY available for CARE 33A) C5
Orientation of rear attachment:0 00015 clockwise 01530 clockwise 03045 clockwise 04560 clockwise 06075 clockwise 07590 clockwise 090105 clockwise 105120 clockwise 120130 clockwise 130150 clockwise 150165 clockwise 165
Voltage:24 V DC 24
Self locking feature (mandatory when selecting load version H or M):No self locking required 0Self locking for pull load 1Self locking for push load 2
C A R E 3 3
Options written in italic fonts are only available on demand. Please contact SKF.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorCALA 36A
BenefitsCompactLubricated for service lifeCorrosion resistantHigh operating reliabilitySelection of front attachmentsLimit switches as accessories
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsCALA 36A
Suitable control units and accessories Dimensional drawing
Connecting diagram
Legend:S = strokeL = retracted length
Limitswitch
+12/24 V DC
M
1 2
2
13 2
13
Limitswitch
CALA 36A 12V
C
A
E
D
3
-
2
4
R
CALA 36A 24V
CAES 31C
8dcigdajc^ih
B
C
U
8
B
C
U
5
V
C
U
9
V
C
U
8
V
C
U
5
EHA3
STJ
STE
C
A
X
C
3
3
*
A^b^ihl^iX]
=VcYhl^iX];ddihl^iX]9Zh`hl^iX]
3
3
2
2
9G6
10
L=S+215
165 250 30
10
2
2
5
2
U
L=S+22611
G5
6
,
1
2
5
,
9
10,1
28
M
1
2
38
L=S+257
G3
T2
2 000 30
T2P
1 900 30
Technical data
Unit CALA 36A
Push load N 600Pull load N 600Speed (full load to no load) mm/s 17 to 311)
Stroke mm 50 to 200Retracted length mm S+215/226/2572)
Voltage V DC 12 or 24Power consumption W N/ACurrent consumption 12 V DC A 4,4
24 V DC A 2,2Duty cycle % 5Ambient temperature C 0 to +50Type of protection IP 44Weight kg 0,9 to 1,4Color Black
1) Depending on selected motor2) Dimension depends on selected front attachment
See page 394*
Front attachments
Rear attachments
2
-
Linear actuators DC versions CALA 36A
Performance diagrams
Speed-load diagram Current-load diagram
0 200 400 600 800
40
30
20
10
0
Speed (mm/s)
Load (N)
0 200 400 600 800
4
3
2
1
0
12 V DC
24 V DC
Load (N)
Current consumption (A)
3
SKF is a registered trademark of the SKF Group
SKF Group 2009The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10362 EN November 2009
CALA 36A
Ordering key
Type
Stroke (S):50 mm 050100 mm 100150 mm 150200 mm 200Other stroke lengths ---
Front attachment:Male thread, M12 G3Fork end, =10,1 mm G5Hole, =10,0 mm G6
Voltage:12 V DC D1224 V DC D24
Cable:Straight 0,25 m, no plug UStraight 1,9 m, no plug T2Straight 1,9 m, jack plug T2PStraight, 2,5 m, DIN8 plug (for BCU/VCU) C5
C A L A 3 6 A X X 4 /
Options written in italic fonts are only available on demand. Please contact SKF.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorCAR 22
BenefitsIndustrial reliable and robust actuatorRight and left hand version
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuators DC versionsCAR 22
Suitable control units and accessories Dimensional drawing
Connecting diagram
10 e8
66,5
53
26
16
M10 1,5
22
35
49L = S + 205
8946
23
23
60
16,5
104
Legend:S = strokeL = retracted length
Technical data
Unit CAR 22
Rated push load N 1 000 to 1 500Rated pull load N 1 000 to 1 500Speed (full load to no load) mm/s 10 to 30Stroke mm 50 to 300Retracted length mm S+ 205Voltage V DC 12 or 24Power consumption W N/ACurrent consumption 12 V DC A 9
24 V DC A 5Duty cycle % 25Ambient temperature C 20 to +70Type of protection IP 44Weight kg 1,2 to 1,6
See page 379*
+12/24 V DC
M
1 2
2
13 2
13
Limitswitch
Limitswitch
D12B
CAED
5-2
4R
D24B
CAES 31C
CA
XB
22*
Limitswitch
Control unit
Hand switch
Foot switch
Desk switch
2
-
Linear actuators DC versions CAR 22
Performance diagrams
CAR 22.../D12B CAR 22.../D24B
V (mm/s)
I (A)
V (mm/s)
I (A)
Gear 1
Gear 2
Duty cycle
0
1
2
3
4
5
6
7
8
9
10
0
4
8
12
16
20
24
28
32
36
40
0
100
200
300
400
500
600
700
800
900
1 0
00
1 1
00
1 2
00
1 3
00
1 4
00
1 5
00
V (mm/s) I (A)
Load (N)
0
1
2
3
4
5
6
7
8
9
10
0
4
8
12
16
20
24
28
32
36
40
0
100
200
300
400
500
600
700
800
900
1 0
00
1 1
00
1 2
00
1 3
00
1 4
00
1 5
00
V (mm/s) I (A)
Load (N)
0
20
40
60
80
100
0 20 40 60 80 100
Duty factor (%) at 20C
Load (N)
3
Ordering key
Type
Motor assembly:Right RLeft L
Stroke (S):50 mm 050100 mm 100150 mm 150200 mm 200300 mm 300Other stroke lengths - - -
Dynamic load (N) / Speed (mm/s) Motor options
1 500/xx 1 000/xx No motor 00001 500/1510 1 000/3020 12 V DC, flat motor, IP44 D12B1 500/1510 1 000/3020 24 V DC, flat motor, IP44 D24B
1 2
C A R 2 2 X X /
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
SKF is a registered trademark of the SKF Group
SKF Group 2010The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 1098 EN August 2010
Printed in Sweden on environmentally friendly paper.
Bearings and units
SealsLubrication
systems
Mechatronics Services
The Power of Knowledge Engineering
Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry world-
wide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
-
Linear actuatorCAR 32
BenefitsIndustrial reliable and robust actuatorWide range of componentsRight- and left-hand version
Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk
Linear actuatorsCAR 32
Suitable control units and accessories Dimensional drawing AC version
Legend:S = strokeL = retracted length
80
109
28
5838
M12X1,7
5
71
L=S+218
150
200
159
55
27,5
27
23 73
Technical data
Unit CAR 32 AC version
Rated push load N 1 500 to 3 500Rated pull load N 1 500 to 3 500Speed (at full load) mm/s 6 to 32*Stroke mm 50 to 700Retracted length mm S + 218Voltage V AC 120 or 230Power consumption 120 V AC W 98 (brake 133,2 W)
230 V AC W 92 (brake 117,3 W)Current consumption 120 V AC A 0,82 (brake +0,29 A)
230 V AC A 0,4 (brake + 0,11 A)Duty cycle % 30Ambient temperature C 20 to +70Type of protection IP 20/54Weight kg 2,1 to 3,7
See page 379*
Depending on selected motor*
Connecting diagram AC version
L1
N
PE
2
CW
0 CCW
120/230 V AC
Bla
ck
Bla
ck
1B
lack
Blu
e
Whit
e
Red
Red
Bro
wn
CAES 31C
CAEV 1
10/2
20
E110C
E110CB
E220C
E220CB
CA
XB
32*
Controlunit
Limitswitch
Hand switch
Foot switch
Desk switch
2
-
Linear actuators CAR 32
Suitable control units and accessories
Technical data
Unit CAR 32 DC version
Rated push load N 1 000 to 3 500Rated pull load N 1 000 to 3 500Speed (full load to no load) mm/s 5 to 60Stroke mm 50 to 700Retracted length mm S+ 218Voltage V DC 12 or 24Power consumption W N/ACurrent consumption 12 V DC A 13
24 V DC A 824 V DC A 5 (for motor D24CW)
Duty cycle % 25Ambient temperature C 20 to +70Type of protection IP 20/44Weight kg 2,1 to 3,7
Dimensional drawing DC version
Legend:S = strokeL = retracted length(a) = cable length(b) = cover for brake (D24CB)(c) = extended shaft (D24CS)
3917987
58
28
100(b
)
74(c
)
20
57
71L=S+218
M12x1,75
38
32
300 mm (a)
300 mm (a)
12 e8
120
75
12
3917987
3917987
120 (c)
104
55
27,5
27,5
23 73
See page 379*
Connecting diagram DC version
+12/24 V DC
M
1 2
2
13 2
13
Limitswitch
Limitswitch
D12C
CAED
5-2
4R
D24C
CAES 31C
CAED
9-2
4R
D24CW
D24CS
D24CB
CA
XB
32*
Limitswitch
Controlunits
Hand switch
Foot switch
Desk switch
3
Duty cycle
CAR 32 ... 230/120 V AC
Current-load diagram CAR 32 ... 120 V AC
Current-load diagram CAR 32 ... 230 V AC
Speed-load diagram CAR 32 ... 120 V AC
Speed-load diagram CAR 32 ... 230 V AC V (mm/s)I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)
Gear 1
Gear 2
Gear 4
0
5
10
15
20
25
30
35
0 1 500 2 500 3 500
Load (N)
Speed (mm/s)
0
5
10
15
20
25
30
35
0 1 500 2 500 3 500
Load (N)
Speed (mm/s)
0
1 5002 5003 500
1 2 46 (E220)/25 F (E110)
4 (E220)/16 F (E110)
3 (E220)/12 (E110)
1 5002 500 900
5009001 500
0 403010 50 60 70 80 90 100
Duty factor (%)
F (N) Gear
0
0,5
1,0
0 1 500 2 500 3 500
Load (N)
Current consumption (A)
0
0,5
1,0
0 1 500 2 500 3 500
Load (N)
Current consumption (A)
Linear actuatorsCAR 32
Performance diagrams AC version
4
-
CAR 32.../D12C
CAR 32.../D24CW
CAR 32.../D24C/D24CS/D24CB
V (mm/s)
I (A)
V (mm/s)
I (A)
V (mm/s)
I (A)
Gear 1
Gear 2
Gear 4
Duty cycle
0
2
4
6
8
10
12
14
16
18
20
0
6
12
18
24
30
36
42
48
54
60
0 500 1 000 1 500 2 000 2 500 3 5003 000
V (mm/s) I (A)
Load (N)
0
2
4
6
8
10
12
14
16
18
20
0
6
12
18
24
30
36
42
48
54
60
0 500 1 000 1 500 2 000 2 500 3 5003 000
V (mm/s) I (A)
Load (N)
0
2
4
6
8
10
12
14
16
18
20
0
6
12
18
24
30
36
42
48
54
60
0 500 1 000 1 500 2 000 2 500 3 5003 000
V (mm/s) I (A)
Load (N)
0
20
40
60
80
100
0 20 40 60 80 100
Duty factor (%) at 20C
Load (N)
Linear actuators CAR 32
Performance diagrams DC version
5
SKF is a registered trademark of the SKF Group
SKF Group 2010The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permis-sion is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can beaccepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10973 EN August 2010
Printed in Sweden on environmentally friendly paper.
Bearings and units
SealsLubrication
systems
Mechatronics Services
The Power of Knowledge Engineering
Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry world-
wide. These fiv