ACOUSTI-SEAL 900 SERIES TECHNICAL DATA · frame. Acoustical ratings of panels with this...
Transcript of ACOUSTI-SEAL 900 SERIES TECHNICAL DATA · frame. Acoustical ratings of panels with this...
10 22 26 (10650)
Operable Partitions
Acousti-Seal®
932FS
Technical Data
1Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 1Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
• Floor-Supported Paired Panels forInstallations where Existing OverheadStructure Cannot Support Partition Weight
• Ideal for Straight-Line Openings withoutMultiple Location or Offset StorageRequirements
• Panels Hinged in Groups of Two ProvideQuick and Easy Setup
• For Applications Requiring ExceptionalDurability, Acoustic Control, and FrequentUse
• Used in Classrooms, Conference or MeetingRooms, and Office Space
• Two Year Warranty on Partition System
• Lifetime Warranty on Standard Hinges
Modernfold Model
Acousti-Seal 932FS Flat Panels, Floor Supported, Paired Panel Operation
This specification along with product information and model details can be downloaded from www.modernfold.com.
SPECIFICATION - SECTION 10 22 26 (10650) OPERABLE PARTITIONS
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATA
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contractincluding General and Supplementary Conditionsand Division 01 Specification Sections, apply tothis Section.
1.2 SUMMARY
A. This Section includes the following:1. Manually operated, paired panel operable
partitions.B. Related Sections include the following:
1. Division 03 Sections for concrete tolerancesrequired.
2. Division 05 Sections for primary structuralsupport, including pre-punching of supportmembers by structural steel supplier peroperable partition supplier’s template.
3. Division 06 Sections for wood framing andsupports, and all blocking at head and jambs asrequired.
4. Division 09 Sections for wall and ceiling framingat head and jambs.
1.3 QUALITY ASSURANCE
A. Installer Qualifications: An experienced installerwho is certified in writing by the operable partitionmanufacturer, as qualified to install themanufacturer’s partition systems for work similar inmaterial, design, and extent to that indicated forthis Project.
B. Acoustical Performance: Test operable partitions inan independent acoustical laboratory in accordancewith ASTM E90 test procedure to attain no lessthan the STC rating specified. Provide a completeand unedited written test report by the testinglaboratory upon request.
C. Preparation of the opening shall conform to thecriteria set forth per ASTM E557 “Standard Guidefor the Installation of Operable Partitions.”
1.4 SUBMITTALS
A. Product Data: Material descriptions, constructiondetails, finishes, installation details, and operatinginstructions for each type of operable partition,component, and accessory specified.
B. Shop Drawings: Show location and extent ofoperable partitions. Include plans, elevations,sections, details, attachments to otherconstruction, and accessories. Indicate dimensions,weights, conditions at openings, and at storageareas, and required installation, storage, andoperating clearances. Indicate location andinstallation requirements for hardware and track,including floor tolerances required and direction oftravel. Indicate blocking to be provided by others.
C. Setting Drawings: Show imbedded items andcutouts required in other work, including supportbeam punching template.
D. Samples: Color samples demonstrating full rangeof finishes available by architect. Verificationsamples will be available in same thickness andmaterial indicated for the work.
2 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATA
1.5 DELIVERY, STORAGE, AND HANDLING
A. Clearly mark packages and panels with numberingsystems used on Shop Drawings. Do not usepermanent markings on panels.
B. Protect panels during delivery, storage, andhandling to comply with manufacturer’s directionand as required to prevent damage.
1.6 WARRANTY
A. Provide written warranty by manufacturer ofoperable partitions agreeing to repair or replace anycomponents with manufacturing defects.
B. Warranty period: Two (2) years.
PART 2 – PRODUCTS
2.1 MANUFACTURERS, PRODUCTS, AND
OPERATION
A. Manufacturers: Subject to compliance withrequirements, provide products by the following:1. Modernfold, Inc.
B. Products: Subject to compliance with therequirements, provide the following product:1. Acousti-Seal #932FS manually operated, floor
supported paired panel operable partition.
2.2 OPERATION
A. Acousti-Seal #932FS: Series of paired flat panelshinged together in pairs, manually operated, floorsupported with no mechanical floor seals.
B. Final Closure (select one):1. Horizontally expanding panel edge with
removable crank2. Hinged panel closure3. Angle jamb4. Pass door closure
2.3 PANEL CONSTRUCTION
A. Nominal 3-inch (76mm) thick panels inmanufacturer’s standard 48-inch (1220mm)widths. All panel horizontal and vertical framingmembers fabricated from minimum 18-gageformed steel with overlapped and welded cornersfor rigidity. Top channel is reinforced to supportsuspension system components. Frame is designedso that full vertical edges of panels are of formedsteel and provide concealed protection of the edgesof the panel skin.
B. Panel Skin Options:1. 1/2-inch (13mm) tackable fire core C gypsum
board, class “A” rated single material or
composite layers continuously bonded to panelframe. Acoustical ratings of panels with thisconstruction (select one):a. 41 STCb. 47 STCc. 50 STC
2. 1/2-inch (13mm) tackable moisture resistantgypsum board, class “A” rated single material orcomposite layers continuously bonded to panelframe. Acoustical ratings of panels with thisconstruction (select one):a. 41 STCb. 47 STCc. 50 STC
3. 1/2-inch (13mm) medium density fiberboard,single material or composite layers continuouslybonded to panel frame. Acoustical ratings ofpanels with this construction (select one):a. 41 STCb. 47 STCc. 50 STC
4. Nominal 21-gage roll-formed steel wrappingaround panel edge. Panel skins shall be lockformed and welded directly to the frame forunitized construction. Acoustical ratings ofpanels with this construction (select one):a. 28 STCb. 45 STCc. 50 STCd. 52 STC
C. Hinges for Panels, Closure Panels, Pass Doors, andPocket Doors shall be (select one):1. Full leaf butt hinges, attached directly to panel
frame with welded hinge anchor plates withinpanel to further support hinge mounting toframe. Lifetime warranty on hinges. Hingesmounted into panel edge or vertical astragal arenot acceptable.
2. SOSS® Invisible laminated hinge with antifrictionsegments mounted between each heat treatedlink. Hinge to be attached directly to panelframe. Welded internal hinge bracket shallsupport the hinge and allow for adjustment ofhinge plates. Concealed hinges mounted intopanel edge or vertical astragal are not acceptable(available on steel skin panel only).
D. Panel Trim: No vertical trim required or allowed onedges of panels; minimal groove appearance atpanel joints.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
3Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
E. Panel Weights:Non-Steel Skin1. 41 STC – 6.5 lbs./square foot2. 47 STC – 7 lbs./square foot3. 50 STC – 8 lbs./square footSteel Skin1. 28 STC – 6 lbs./square foot2. 45 STC – 8 lbs./square foot3. 50 STC – 8 lbs./square foot4. 52 STC – 11 lbs./square foot
2.4 PANEL FINISHES
A. Panel Finish: Factory applied, Class “A” ratedmaterial. Finish shall be (select one):1 .Reinforced vinyl with woven backing weighing
not less than 15 ounces per lineal yard.2. Reinforced heavy duty vinyl with woven backing
weighing not less than 27 ounces per linealyard.
3. Acoustical, non-woven needle punch carpet, withfused fibers to prevent unraveling or fray ofmaterial.
4. Wall covering and upholstery fabric with surfacetreatment to resist stains.
5. Customer’s own material (subject to factoryapproval).
6. Full height tackboard with vinyl or fabric covering.a. 1/4-inch natural corkb. 1/4-inch fiber board tackbase
7. Full height steel work surfaces (chalkboard ormarkerboard).
8. High pressure plastic laminate on MDF board.9. Wood veneer on MDF board.10. Reconstituted wood veneer (Uni-FormWood) on
steel skin.11. Uncovered for field finishing.12. Primed for field finishing.
B. Panel Trim: Exposed panel trim of one consistentcolor (Smoke Gray or Dark Bronze).
2.5 SOUND SEALS
A. Vertical Interlocking Sound Seals between panels:Roll-formed steel astragals, with reversible tongueand groove configuration in each panel edge foruniversal panel operation. Rigid plastic astragals orastragals in only one panel edge are notacceptable.
B. Horizontal Top and Bottom Seals: Continuouscontact extruded vinyl bulb shape with pairs of non-contacting vinyl fingers to prevent distortionwithout the need for mechanically operated parts.
2.6 SUSPENSION SYSTEM
A. #17 Floor Supported Suspension System 1. Floor Track: Minimum 16-gage stainless steel
shall support nominally 80% or more of thepanel weight. Surface mounted application shallrequire no alteration of the floor surface.Recessed floor track shall require a kerf no widerthan 1-inch (25mm) nor deeper than 1-inch(25mm).
2. Suspension Tracks: Minimum 11-gage, 0.12-inch (3.04mm) roll-formed steel track, suitablefor either direct mounting to a wood header orsupported by adjustable steel hanger brackets,supporting the load-bearing surface of the track,connected to structural support by pairs of 3/8-inch (9.5mm) diameter threaded rods.Aluminum track is not acceptable.a. Exposed track soffit: Steel, integral to track,
and pre-painted off-white.3. Carriers: One all-steel trolley with steel-tired ball
bearing wheels per panel (except hinged panels).Non-steel tires are not acceptable.
2.7 OPTIONS
A. Single Pass Doors (select one):1. Standard hollow metal door hung in a steel
frame. ADA compliant pass door to be equippedwith friction latch and flush pulls for panicoperation. No threshold will be permitted. a. Pass door to be prime painted for field
finishing.b. Pass door to be painted dark bronze or smoke
gray.2. Matching pass door same thickness and
appearance as panels. ADA compliant pass doorto be trimless and equipped with friction latchand flush pulls for panic operation. No thresholdwill be permitted.
3. Hardware:a. Automatic door closures.b. Self-Illuminated exit signs.b. Panic hardware.
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATA
4 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
B. Work Surfaces:1. Tackboard: Minimum 1/4-inch (6.35mm) natural
cork, covered with vinyl or fabric, with horizontaltrim without exposed fasteners. Trim is notacceptable on vertical edges.
2. Markerboard: White enamel on steel, bonded tothe face of the panel with horizontal trim withoutexposed fasteners. Trim is not acceptable onvertical edges to provide uninterrupted worksurface.
3. Chalkboard: Porcelain enamel on steel, bondedto the face of the panel with horizontal trimwithout exposed fasteners. Trim is notacceptable on vertical edges to provideuninterrupted work surface.
C. Available Accessories/Options:1. Pocket Doors: Acousti-Seal Pocket Doors by
Modernfold, Inc., with same construction, finish,and appearance as the adjacent panels.
2. Finished end caps.3. Intersecting partition interface.4. Inset window options - glazed or unglazed.
PART 3 – EXECUTION
3.1 INSTALLATION
A. General: Comply with ASTM E557, operablepartition manufacturer’s written installationinstructions, Drawings and approved ShopDrawings.
B. Install operable partitions and accessories afterother finishing operations, including painting, havebeen completed.
C. Match operable partitions by installing panels frommarked packages in numbered sequence indicatedon Shop Drawings.
D. Broken, cracked, chipped, deformed, or unmatchedpanels are not acceptable.
3.2 CLEANING AND PROTECTION
A. Clean partition surfaces upon completinginstallation of operable partitions to remove dust,dirt, adhesives, and other foreign materialsaccording to manufacturer’s written instructions.
B. Provide final protection and maintain conditions ina manner acceptable to the manufacturer andinstaller that insure operable partitions are withoutdamage or deterioration at time of SubstantialCompletion.
3.3 ADJUSTING
A. Adjust operable partitions to operate smoothly,easily, and quietly, free from binding, warp,excessive deflection, distortion, nonalignment,misplacement, disruption, or malfunction,throughout entire operational range. Lubricatehardware and other moving parts.
3.4 EXAMINATION
A. Examine flooring, structural support, and opening,with Installer present, for compliance withrequirements for installation tolerances and otherconditions affecting performance of operablepartitions. Proceed with installation only afterunsatisfactory conditions have been corrected.
3.5 DEMONSTRATION
A. Demonstrate proper operation and maintenanceprocedures to Owner’s representative.
B. Provide Operation and Maintenance Manual toOwner’s representative.
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATA
STC CONSTRUCTION AND TRACK SYSTEM HEIGHT LIMITATIONS
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
5Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
Acousti-Seal 932FSStandard Panel Joint
NOMINAL 21 GA. STEELSKINS WITHACOUSTICAL BACKER
ROLL-FORMED EDGESWRAPPED AROUND,LOCKED AND WELDEDTO VERTICAL FRAME
STEEL DUAL INTERLOCKING VERTICAL ASTRAGAL WITH VINYL ACOUSTICAL GASKET
ROLL-FORMEDSTEEL VERTICALFRAME CHANNELWITH NO SHARPEDGESMINIMUM GROOVE
AT PANEL JOINT WITH NO VERTICAL EDGE TRIM
16 GA. ROLL-FORMEDSTEEL VERTICALFRAME CHANNEL
ACOUSTICALINSULATION
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATASTEEL SKIN PANEL CONSTRUCTION
STEELBALLBEARINGTROLLEYS
16 GA. FORMED
FRAME CHANNELSTEEL BOTTOM
SOLID STEELTROLLEY MOUNT
.75" (19mm)
DOUBLE 16 GA.STEEL TOP CHANNELWITH HEAVYSTEEL CORNERREINFORCEMENTS
FIXED FLOORSEAL
STAINLESSSTEEL TRACK
TRACK/SOFFITUNDERSIDE OF
FLOOR
NON-DISTORTINGBUB-AND-FINGERACOUSTICAL SWEEP
FORMED STEELSKIN WITH NOSHARP EDGES WELDED TO FRAME
INSULATEDBOTTOMSEAL CAVITYWITH DOUBLEACOUSTICALSEALS
Acousti-Seal 932FSPanel Section Frame Details
Roll-formed skin wraps completely around the edge
of vertical 16-gage steel channel and is locked in
place, eliminating any sharp edges and creating a
unitized panel. The finish material is secured under
the steel astragal to prevent peeling.
PANEL DETAILS ARE NOT TO SCALE
STEEL BUTTHINGES ATTACHDIRECTLY TO HEAVY STEELBACKER PLATESWELDED TO FRAME
FINISH MATERIAL WRAPPED AROUND PANEL EDGE AND CAPTURED BY VERTICAL ASTRAGAL
16 GA. ROLL-FORMEDSTEEL VERTICAL FRAMECHANNEL WITH NOSHARP EDGES
ROLL-FORMED EDGESWRAPPED AROUND,LOCKED AND WELDEDTO VERTICAL FRAME
Heavy steel hinges are mounted directly to the
center of the vertical frame channel, not simply on
the outside edge of the panel. Steel plates welded to
the back of the channel prevent buckling or bending
and provide the strongest hinged connection.
AS-41
Model Detail from Website
AS-42R
Model Detail from Website
6 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATANON-STEEL SKIN PANEL CONSTRUCTION
Acousti-Seal 932FSStandard Panel Joint
BUILT-IN CONCEALEDEDGE PROTECTIONFOR PANEL SKIN
FINISH MATERIAL WRAPPEDAROUND PANEL EDGE ANDCAPTURED BY VERTICAL ASTRAGAL
18 GA. ROLL-FORMED STEEL VERTICAL FRAMECHANNEL WITH NOSHARP EDGES
FULL WIDTHLAMINATEDPANEL SKIN WITHCONTINUOUSPERIMETER BOND
STEEL DUALINTERLOCKING VERTICALASTRAGAL WITH VINYLACOUSTICAL GASKET
FINE LINE PANELJOINT WITH NOVERTICAL EDGE TRIM
ACOUSTICALINSULATION
BULB-AND-FINGERACOUSTICAL SWEEP
UNDERSIDE OFTRACK/SOFFIT
FULL PERIMETER18 GA. STEEL FRAMEWITH OVERLAPPEDAND WELDEDCORNERS
14 GA.REINFORCEDFORMED STEELTOP CHANNEL
.63" (16mm)SOLID STEELTROLLEY MOUNT
FIXED FLOORSEAL
FLOOR
STEEL BALLBEARINGTROLLEYS
STAINLESSSTEEL TRACK
Acousti-Seal 932FSPanel Section Frame Details
Roll-formed vertical frame channel provides added
strength while eliminating any sharp edges. The
outer covering is secured under the steel astragal to
prevent peeling. The complete vertical edge of the
panel is steel for maximum durability.
PANEL DETAILS ARE NOT TO SCALE
BUILT-IN CONCEALEDEDGE PROTECTIONFOR PANEL SKIN
FULL WIDTHLAMINATEDPANEL SKIN WITHCONTINUOUSPERIMETER BOND
STEEL DUALINTERLOCKING VERTICALASTRAGAL WITH VINYLACOUSTICAL GASKET
FINE LINE PANELJOINT WITH NOVERTICAL EDGE TRIM
18 GA. ROLL-FORMED STEEL VERTICAL FRAMECHANNEL WITH NOSHARP EDGES
ACOUSTICALINSULATION
FINISH MATERIAL WRAPPED AROUND PANEL EDGE AND CAPTURED BY VERTICAL ASTRAGAL
STEEL BUTT HINGES ATTACH DIRECTLY TOHEAVY STEEL BACKER PLATES WELDEDTO FRAME
Heavy steel hinges are mounted directly to the
center of the vertical frame channel, not simply on
the outside edge of the panel. Steel plates welded to
the back of the channel prevent buckling or bending
and provide the strongest hinge connection.
NG-68
Model Detail from Website
NG-69R
Model Detail from Website
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
7Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
CONTINUOUS AND LEVELHEADER 2 x 10 MIN. HEADERNOT BY MODERNFOLD
#17 STEEL TRACK AND DROP SOFFIT TRIM PREPAINTEDOFF-WHITE
STEEL, 4-WHEELBALLBEARING TROLLEYS
VINYL TOP SEAL
FIXED SEAL
SURFACE MOUNTEDFLOOR TRACK
.62" x .62"STEEL BARBY MODERNFOLD
4.25"TRACK
.38"
.69"
2.1
2"
2
.50
" M
IN.
FAB
RIC
ATIO
N H
EIG
HT
.75"
3.16"
AS-85
Model Detail from Website
#17 Track System Direct Mount w/Surface Mount Floor Track
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATASUSPENSION SYSTEM OPTIONS
8 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
.38" DIA. x 7" LONGHANGER RODSBY MODERNFOLD
HANGER BRACKETBY MODERNFOLD
#17 STEEL TRACK ANDDROP SOFFIT TRIMPREPAINTED OFF-WHITE
STEEL, 4-WHEELBALLBEARING TROLLEYS
VINYL TOP SEAL
FIXED SEAL
SURFACE MOUNTEDFLOOR TRACK
.62" x .62"STEEL BAR
BY MODERNFOLD
5.75"BRACKET
4.50"GAGE
4"
MIN
.
.75"
FAB
RIC
ATIO
N H
EIG
HT
3.16"
.69"
4.25"TRACK
.38"
#17 Track System Bracket Mount w/Surface Mount Floor Track
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATASUSPENSION SYSTEM OPTIONS
AS-87
Model Detail from Website
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
9Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
#17 Track System Direct Mount w/Recessed Mount Floor Track
AS-86
Model Detail from Website
2.5
0"
MIN
.2
.12
"
.75"
CONTINUOUS AND LEVELDOUBLE 2 x 10 MIN.HEADER NOT BY MODERNFOLD
#17 STEEL TRACK ANDDROP SOFFIT TRIMPREPAINTED OFF-WHITE
STEEL, 4-WHEELBALLBEARING TROLLEYS
VINYL TOP SEAL
1.00"RECESS
1.00"RECESS
3.16"
FIXED SEAL
RECESSED FLOORTRACK
.25" x .62"STEEL BARBY MODERNFOLD
FAB
RIC
ATIO
N H
EIG
HT
.31"
FINISHEDFLOOR
4.25"TRACK
GROUTNOT BY MODERNFOLD
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATASUSPENSION SYSTEM OPTIONS
10 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
Acousti-Seal®
932FS
Technical Data
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATASUSPENSION SYSTEM OPTIONS
.38" DIA x 7" LONGHANGER RODSBY MODERNFOLD
HANGER BRACKETBY MODERNFOLD
#17 STEEL TRACK ANDDROP SOFFIT TRIMPREPAINTED OFF-WHITE
STEEL, 4-WHEELBALLBEARING TROLLEYS
VINYL TOP SEAL
FIXED SEAL
RECESSED FLOORTRACK
.25" x .62"STEEL BARBY MODERNFOLD
5.75"BRACKET
4.50"GAGE
4"
MIN
.
.75"
1.00"RECESS
GROUTNOT BY MODERNFOLD 3.16"
1.00"RECESS
FAB
RIC
ATIO
N H
EIG
HT
FINISHEDFLOOR
.31"
4.25"TRACK
#17 Track System Bracket Mount w/Recessed Mount Floor Track
AS-88
Model Detail from Website
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
11Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPANEL, WORK SURFACE, AND PASS DOOR OPTIONS
SELF-LUMINOUS EXIT SIGNS(SURFACE OR RECESSED MOUNTED)
NO VERTICAL TRIMON PANEL (TYPICAL)
"H" TYPE PASSDOOR
SELF-LUMINOUS EXIT SIGN (OPTIONALLOCATION)
RECESSED HAND PULL WITHFRICTION LATCH (ADA COMPLIANT)
CHALKBOARD, MARKERBOARD,OR TACKBOARD (NO VERTICALTRIM REQUIRED) RECESSED ERASER
HOLDER
6'-8
" O
R 7
'-0"
VAR
IAB
LE
4'-0
"
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPOCKET ENCLOSURE AND STACKING OPTIONS
OPTIONALPOCKET
STACKDEPTH
NO. OF PANELSx 3.75" + 2"
1/2
PAN
EL W
IDTH
PLU
S 4"
MIN
.1/
2 PA
NEL
WID
THPL
US
7" M
IN.
SIDE RSIDE L
STACKDEPTH
NO. OF PANELSx 3.75" + 2"
SIDE RSIDE L
1/2
PAN
EL W
IDTH
PLU
S 4"
MIN
.1/
2 PA
NEL
WID
THPL
US
7" M
IN.
OPTIONALPOCKET
Expandable Jamb Closure - Even Panel Quantity
Expandable Jamb Closure - Odd Panel Quantity
12 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPOCKET ENCLOSURE AND STACKING OPTIONS
TYPE IIPOCKETDOOR
STACK DEPTH PLUS 6" MIN.
SIDE RSIDE L
STACKDEPTH
NO. OF PANELSx 3.75" + 2"
1/2
PA
NE
LW
IDTH
PLU
S 7
" M
IN.
1/2
PA
NE
WID
THP
LUS
10
" M
IN.
STACKDEPTH
NO. OF PANELSx 3.75" + 5"
SIDE RSIDE L
1/2
PAN
EL W
IDTH
PLU
S 4"
MIN
.1/
2 PA
NEL
WID
THPL
US
7" M
IN.
OPTIONALPOCKET
SIDE RSIDE L
1/2
PA
NE
L W
IDTH
PLU
S 4
" M
IN.
1/2
PA
NE
L W
IDTH
PLU
S 7
" M
IN.
STACKDEPTH
NO. OF PANELSx 3.75" + 5"
OPTIONALPOCKET
1/2
PA
NE
LW
IDTH
PLU
S 4
" M
IN.
TRA
IL P
AN
EL
SIZ
EP
LUS
4"
MIN
.
1/2
PA
NE
LW
IDTH
PLU
S 7
" M
IN.
STACKDEPTH
NO. OF PANELSx 3.75" +4"
SIDE RSIDE L
Remote Expandable Jamb ClosureAngle Jamb Closure - Odd Panel Quantity
Angle Jamb Closure - Even Panel Quantity Pass Door Closure
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
13Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPOCKET ENCLOSURE AND STACKING OPTIONS
SIDE RSIDE L
STACKDEPTH
NO. OF PANELSx 3.75" + 4"
1/2
PA
NE
L W
IDTH
PLU
S 4
" M
IN.
1/2
PA
NE
L W
IDTH
PLU
S 7
" M
IN.
OPTIONALPOCKET
SIDE RSIDE L
STACKDEPTH
NO. OF PANELSx 3.75" + 4"
1/2
PA
NE
L W
IDTH
PLU
S 4
" M
IN.
1/2
PA
NE
L W
IDTH
PLU
S 7
" M
IN.
OPTIONALPOCKET
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPANEL CROSS SECTIONS
CAULKING BETWEENJAMB AND WALL
JAMB FINISH SAMEAS PANELS
AS-31R
Model Detail from Website
0" TO 5.75"TRAVEL
CAULKING BETWEENJAMB ANDWALL
EXPANDABLE PANELNOSE - FINISHSAME AS PANELS
JAMB FINISH SAMEAS PANELS
AS-34
Model Detail from Website
Bi-fold Hinged Panel Closure Single Hinged Panel Closure
Hinged Jamb Expandable Panel w/ Jamb
14 Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPANEL CROSS SECTIONS
0" TO 5.75"TRAVEL
EXPANDABLE PANELNOSE - FINISHSAME AS PANELS
VINYL BULB SEAL
AS-36
Model Detail from Website
END CAP
CAULKING BETWEENJAMB AND WALL
STEEL ANGLE WRAPPEDWITH FINISH MATERIAL
VINYL SWEEP
AS-39R
Model Detail from Website
1.50"REF.
STOPS
AS-69R
Model Detail from Website
1"(25MM)
ALUMINUM ASTRAGALCOVERED TO MATCH
PANEL FINISH (OPTIONAL)
AS-43L
Model Detail from Website
Expandable Panel w/ Bulb Seal Angle Jamb
Hinged Panel Meeting w/ Bulb SealHinged Panel Meeting w/ Pass Door Astragal
STEEL BUTT HINGES ATTACHDIRECTLY TO FRAME WITHHEAVY STEEL BACKER PLATES
NG-69R
Model Detail from Website
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
15Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.
ACOUSTI-SEAL® 900 SERIES TECHNICAL DATAPANEL CROSS SECTIONS
CAULKING BETWEENJAMB AND WALL
FINISH SAMEAS PANELS
AS-21
Model Detail from Website
CAULKING BETWEENJAMB AND WALL
FINISH SAMEAS PANELS
AS-22
Model Detail from Website
VINYL SEAL ANDSTEEL ASTRAGAL
VINYL BULBSEAL
3.0
0"
RE
F
AS-49
Model Detail from Website
Standard Hinged Panel Joint Bulb Seal and Intersection
Nominal Fixed Jamb Variable Fixed Jamb
10 22 26
Operable Partitions
Acousti-Seal®
932FS
Technical Data
Modernfold, Inc.
Toll Free: 800.869.9685
www.modernfold.com
email: [email protected]
A DORMA Group Company
www.dorma-usa.comForm No. 2433 2/07
Manufacturer reserves the right to change design or specifications at any time without notice.
Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.