ABB SSAC Timers and Controls In Stock Products · Full Line Catalog Available On CD-ROM Request...
Transcript of ABB SSAC Timers and Controls In Stock Products · Full Line Catalog Available On CD-ROM Request...
AC 1008-2
ABBSSACTimers and ControlsIn Stock Products
Low Voltage Products & Systems
IN STOCK
Full Line Catalog Available On CD-ROMRequest SS2-CDR
IN STOCK
Delay on MakeCT-ERD timetron
p. 9
7 FunctionsCT-MFD timetron
p. 7
www.ssac.com
In Stock ProductsMultifunction, MultirangeTime Delay Relays
6 FunctionsTRU Series
p. 6
8 FunctionsCT-MFS timetron
p. 4
21 FunctionsTRDU Series
p. 2
Single Function Timers
AccurateSwitch Adjustment TD Series p. 10
Solid State Encapsulated TDU Series p. 14
Knob Adjust Solid State TMV8000 p. 15
Solid State FlashersCost Effective OEM DesignFS100 Series p. 18
Universal Voltage Knob AdjustFSU1000 Series p. 18
Motor & Pump ControlsLiquid Level Controls LLC5 Series p. 30
Alternating RelaysDuplexing Relays ARP Series p. 29
Current Sensors & IndicatorsAC Current Indicator LCS10T12 & LPM p. 28
Over/UnderCurrent Sensing ECS Series p. 25
AC Current Transducer TCSA Series p. 27
AC Current Switch TCS Series p. 26
Tower & Obstruction Lighting Controls
ICVR1E2S 10.24.03
B-Kon Flasher FS155-30T p. 19
Lamp Alarm Relays SCR & FB Series p. 19
Motor Protector3 Phase Voltage Monitors
10 Fault Memory WVM Series
p. 20
Universal VoltagePLMU Seriesp. 22
DIN Rail orSurface Mounting DLM Series
p. 23
1
SELG1E2S 03.29.04
www.ssac.com
1919191919191919
2526272828
20, 21
23
24
22
181818
131313131214151616161617
Selection GuideSeries Page Description Timing Function Voltage Output
Time Delay Relays - Isolated Relay Output
Timing Modules - Totally Solid State, Encapsulated (Except CT-MKE) 17.5 mm DIN or Surface, Universal: Delay, Function, & Voltage 17.5 mm DIN or Surface, Universal: Delay, Function, & Voltage 17.5 mm DIN or Surface, Universal: Delay, Function, & Voltage 17.5 mm DIN or Surface, Universal: Delay, Function, & Voltage 22.5 mm DIN3 Mount, Knob Adjustable, 0.1...300 s Universal Voltage, Switch Settable, 0.1s...2.8h Universal Voltage, Knob or Ext. Adjustment, 0.1...8m Versa-Timer, Ext. Adj., 0.05 ... 600 s Versa-Timer, Ext. Adj., 0.05 ... 600 s Versa-Timer, Ext. Adj., 0.05 ... 600 s Versa-Timer, Ext. Adj., 0.05 ... 600 s Switch Settable, 0.1 s ... 17.1 h
Multifunction Multifunction Multifunction Multifunction Multifunction
Delay on Make Delay on Make Delay on Make
Interval Single Shot
Delay on Break Recycling
9 ... 240 V9 ... 240 V9 ... 240 V9 ... 240 V
24 ... 240 V AC/DC24, 240 V AC/DC
24... 240 V AC/DC120 V AC120 V AC120 V AC120 V AC120 V AC
0.7 A SPST0.7 A SPST0.7 A SPST0.7 A SPST0.8 A SPST1 A SPST1 A SPST1 A SPST1 A SPST1 A SPST1 A SPST1 A SPST
Flashers - Encapsulated, Totally Solid State, Surface MountFS100FS300FSU1000
V AC Low Cost, Small Size, Wire Leads V DC Solid State Flashers, 0.25" Terminals V AC Universal Voltage, Low to High Power, 0.25" Terminals
24, 120 V AC12, 24 V DC
24 ... 240 V AC
1, 2 A SPST1.5-2.5 A SPST1-20 A SPST
Alternating Relay - 8 Pin or 11 Pin Plug-in BaseARP Shares Run Time of Two Motors 120 V AC 10 A DPDT
WVM
DLM
RLM
PLMU
Under & Overvoltage, Knob Adjust, 10 Fault Memory Status Indicators, Surface Mounting Under & Overvoltage, Knob Adjust, LED Indicator, 35 mm DIN Rail or Surface Mounting Undervoltage, Knob Adjust LED Indicator Encapsulated, Surface Mounting Auto Range Selection, Under & Overvoltage, Knob Adjust, LED, 8 Pin Plug-in Base
200 ... 600 V AC
200 ... 600 V AC
200 ... 480 V AC
200 ... 480 V AC
10 A SPDT
10 A SPDT
8 A SPDT
10 A SPDT
3 Phase Voltage Monitors - Senses Phase Loss, Reversal, Unbalance
AC Current Sensors - Toroidal Sensor, EncapsulatedECSTCSTCSALCSLPM
0.5 ... 20 A, Over or Under Current Sensing, Knob Adjust, Relay Output 2 A, Go No/Go Sensing, N.O. or N.C. Solid State Output, Knob Adjust 0.5 ... 50 A, Loop Powered Current Transducer, 4 ... 20 mA Output 5 ... 50 A Current Sensor, 0.36 in. (9.1 mm) Through Hole, Wire Leads Current Indicator for LCS, Select Green or Red LED
24, 120 V AC3 ... 240 V
10 ... 30 V DCN/AN/A
10 A SPDT1 A SPST
4 ... 20 mAN/AN/A
LLC5 Knob Adjust to 100 K Ohms, Fill or Drain
Conductive Liquid Level Control - Dual Probe, 8 Pin Plug-in120 V AC 5 A SPDT
Tower and Obstruction Lighting Controls
Accessory Pages 31-34
ASQUASTUDSQUDSTUCT-MKETDUTMV, TSUTS1TS2TSSTSBRS
TRDU
CT-MFSTRUCT-MFDCT-ERSCT-ERD
TDMTDITDSTDBTDR
Universal Delay, Multifunction, Switch Settable, 0.1 s ... 71 days; 8 or 11 pin plug-in 22.5 mm DIN3 Mount, Switch Settable, 0.05 s ... 300 hUniversal: Delay, Function, & Voltage, 8 or 11 pin plug-in 17.5 mm DIN3 Mount, Adjustable, 0.05 s ... 100 h 22.5 mm DIN3 Mount, Knob Adjustable, 0.05 s ... 300 h 17.5 mm DIN3 Mount, Adjustable, 0.05 s ... 100 h
Switch Settable, 0.1 s ... 2.8 h, 8 pin plug-in Switch Settable, 0.1 s ... 2.8 h, 8 pin plug-in Switch Settable, 0.1 s ... 2.8 h, 8 or 11 pin plug-in Switch Settable, 0.1 s ... 2.8 h, 8 or 11 pin plug-in Switch Settable, 0.1 s ... 2.8 h, 8 pin plug-in
Multifunction
Multifunction Multifunction Multifunction
Delay on Make Delay on Make
Delay on Make Interval
Single Shot Delay on Break
Recycling
10 A SPDT/DPDT
4 A SPDT/DPDT10 A SPDT/DPDT
4 A SPDT4 A SPDT/DPDT
4 A SPDT
10 A DPDT10 A DPDT
10 A SPDT/DPDT10 A SPDT/DPDT
10 A DPDT
24, 120, 230 V
24 ... 240 V AC/DC19 ... 264 V24 ... 240 V
12 ... 240 V in 5 ranges24 ... 240 V
12 ... 120 V24, 120 V24, 120 V24, 120 V120 V AC
2,3
4,56789
1010101011
29
30
Part Number Page DescriptionFS155-30TFS155-30RFFA155FA155-2PCR10, PCR11SCR430TSCR490DFB120A
Beacon Solid State Flasher for 1 or 2 BeaconsSame as FS155-30T Except Designed for High RFProvides Alternate Flashing or Constant Line LoadingFor Synchronous Operation of Additional BeaconsPhoto Control Calibrated to FAA/FCC StandardsLight Alarm Relay, Senses Failure of Flashing or Non-Flashing LampsLight Alarm Relay, Senses 1 out of up to 9 Non-Flashing LampsFlasher and Lamp Failure Alarm Relay
Up to 2500 W SPSTUp to 2500 W SPSTUp to 2500 W SPSTUp to 2500 W SPST
Two 20 A NO Contacts10 A SPDT10 A SPDT10 A SPDT
120 V AC120 V AC120 V AC120 V AC120 V AC120 V AC120 V AC120 V AC
2
TRDU2E2S 10.14.03
24 V AC/DC 24 V AC/DC120 V AC120 V AC120 V AC230 V AC230 V AC230 V AC
8-pin SPDT 11-pin DPDT 8-pin DPDT* 8-pin SPDT 11-pin DPDT 8-pin DPDT* 8-pin SPDT 11-pin DPDT
TRDU24A2 TRDU24A3 TRDU120A1 TRDU120A2 TRDU120A3 TRDU230A1 TRDU230A2 TRDU230A3
www.ssac.com
Time DelayType MicrocontrollerRange: Switch Selectable* SINGLE FUNCTIONS: 0.1 s ... 1,705 h in 8 ranges DUAL FUNCTIONS: 0.1 s ... 3,100 m each in 8 ranges
Adjustments Three switches are provided to set secs/mins & multipliers of x0.1, x1, x10, or x100
Setting Accuracy +/-1% or 50 ms, whichever is greaterRepeat Accuracy +/-0.1% or 16 ms, whichever is greaterTiming Functions Five switches are provided to set one of
twenty-one single or dual functionsReset Time ≤ 50 msInitiate Time 120 V AC: 75 msTime Delay vs. Temperature & Voltage +/-1%IndicationTwo LED's indicate 1) Input voltage applied; 2) Output relay statusInputVoltage 12 V DC, 24 V AC/DC, 120 V AC, or 230 V ACTolerance 12 V DC & 24 V DC/AC -15% ... +20% 120 & 230 V AC -20% ... +10%Frequency 50 ... 60 HzPower Consumption ≤ 3 W; 12 V DC – ≤ 2 WOutputType Electromechanical relayForm SPDT or DPDTRating 10 A resistive at 28 V DC; 10 A resistive at 240 V AC
1/3 hp at 120 & 240 V ACLife Mechanical – 1 x 107; Full Load – 1 x 106
ProtectionIsolation Voltage ≥ 1500 V RMS input to outputPolarity DC units are reverse polarity protectedMechanicalMounting Plug-in socketPackage 3.1 x 2.39 x 1.78 in. (78.7 x 60.7 x 45.2 mm)Termination Octal Plug (8-pin) or Magnal Plug (11-pin)EnvironmentalOperating Temperature -20°C ... +65°CStorage Temperature -40°C ... +85°CWeight ≅ 5.8 oz (164 g)
Microcontroller +/-0.1% Repeat AccuracyMultifunction – 21 FunctionsMultirange – 0.1 s ... 1,705 h in 8 RangesSwitch Selectable Functions, Time Delay, & RangesAC and DC Input Voltages are Available10 A, Isolated SPDT or DPDT Output Contacts
DescriptionThe TRDU Series is a versatile universal timedelay relay with twenty-one selectable singleand dual functions. The dual functions replaceup to three timers required to accomplish thesame function. Both the function and the timingrange are selectable with switches located onthe face of the unit. Two LED's indicate inputvoltage and output status. This device offersfull 10 A isolated relay output contacts in eitherSPDT or DPDT. The TRDU replaces hundredsof part numbers, thereby, reducing your stockinventory requirements.
MultifunctionTRDU SeriesTime Delay Relay
21 FunctionsFive switches are provided to set one of 10 single or11 dual functions.Single Functions -
* Delay on MakeDelay on Break
* Recycle (On Time First, Equal Recycle Delays)Single Shot
* IntervalTrailing Edge Single ShotInverted Single ShotInverted Delay on BreakAccumulative Delay on MakeRetriggerable Single Shot (Motion Detector)
Dual Functions -Delay on Make/Delay on Break
* Delay on Make/Recycle(On Time First, Equal Recycle Delays)
* Delay on Make/IntervalDelay on Make/Single Shot
* Interval/Recycle(On Time First, Equal Recycle Delays)
Delay on Break/Recycle(On Time First, Equal Recycle Delays)
Single Shot/Recycle(On Time First, Equal Recycle Delays)
* Recycle - Both Times Adjust. (On Time First)* Recycle - Both Times Adjust. (Off Time First)* Interval/Delay on Make
Accumulative Delay on Make/Interval*9 FUNCTIONS in 8-PIN DPDT UNITS
*For CE approved applications, power must be removed from the unit when a switch position ischanged.
V = Voltage S1 = Initiate Switch
8-Pin DPDT
8-Pin SPDT
11-Pin DPDT
Relay contacts are isolated. Dashed lines areinternal connections.
Inches (Millimeters)
Part NumberBase ConnectionInput Voltage
*Limited to Nine Timing Functions Also Available in 12 V DC & 24 V AC/DC 8-Pin DPDT
Accessories
See accessory pages for specifications.
Panel mount kitP/N: BZ1
Hold down clipsP/Ns: PSC8 (NDS 8) PSC11 (NDS 11)
11-pin socketP/N: NDS 11
Octal8-pin socketP/N: NDS 8
DIN railP/Ns:C103PM (Al)17322005 (Steel)
Technical Data
3
ON
A B C D E
Single Functions Dual Functions
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
A B C D E
ON
A B C D E
ON
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
ON
A B C D E
A B C D E
ON
TRDU2E2RS 10.14.03
www.ssac.com
Delay On Make
Delay On Break
Recycle(ON Time First, Equal Delays)
Single Shot
Interval
Trailing EdgeSingle Shot
InvertedSingle Shot
InvertedDelay On Break
RetriggerableSingle Shot
AccumulativeDelay On Make
Accumulative Delay on MakeInterval
IntervalDelay On Make
Recycle (OFF Time First) Both Times Adjustable
Recycle (ON Time First) Both Times Adjustable
Single ShotRecycle (ON Time First)
Delay On BreakRecycle (ON Time First)
Delay On MakeDelay On Break
Delay On MakeRecycle (ON Time First)
Delay On MakeInterval
Delay On MakeSingle Shot
IntervalRecycle (ON Time First)
* 9 Functions included in the 8 pin DPDT models
*
*
*
*
*
*
*
*
*
5 Switches for Function Selection3 Switches for Time Delay Range
KEY V=Voltage, R=Reset, S1=Initiate Switch, NO=Normally OpenContact, NC=Normally Closed Contact, TD,TD1,TD2=Complete TimeDelay, t=Partial Time Delay, DOM=Delay On Make, DOB=Delay OnBreak, REC=Recycle, SS=Single Shot, INT=Interval, M=Minutes,S=Seconds, = Undefined time
NOTE: The time delay range is the same forboth functions when dual functions are selected.
4
ABB
24 ... 240 V AC/DC 1SVR 430 010 R 0200
MFS02E2S 11.06.03
www.ssac.com
Y1
Z2 X1S2
Z2 S1
L1/L+
Z2 X1
Y1
A1 15 X1Z1 Z2 2521
2521
A2
A1
16 18 2622 24
28
2824 2622 Y118 16 A2
15
N/L-
Potentiometer
L1/L+
Z1Z2
A1
A1
A2
15 X1Z1 Z2
Z1
Z2
Z2
50 k
2521252115
16 18 2622
2824
26222824 Y1A21618
N/L-
1 0.05 - 1 s* 6 15.0 - 300 s2 0.15 - 3 s* 7 1.50 - 30 m3 0.50 - 10 s 8 15.0 - 300 m4 1.50 - 30 s 9 1.50 - 30 h5 5.00 - 100 s 10 15.0 - 300 h
* Green LED does not flash during timing.
Multifunction TimerCT-MFS timetron®
Relay Output
0.05 s ... 300 h in 10 Ranges≤ +/-0.2% Repeat Accuracy24 ... 240 V AC/DC Universal Voltage4 A Isolated SPDT Relays2nd SPDT Relay can be Time Delayed or Instantaneous8 Switch Selectable FunctionsSelect Onboard or External Time AdjustmentTraditional or Accumulative Timing (most functions)3 LED's to Display Operational Status
InputVoltage/Power Consumption A1-A2 24 ... 240 V AC/DC / 2 ... 2.5 VA / WTolerance/Frequency -15 % ... +10 % / 50 ... 60 HzControl Contact /Switch Connections Y1-Z2 Initiate/Reset Switch
X1-Z2 Stop & hold or accumulative timing switchVoltage supplied at the Switch Inputs 10 ... 40 V DCSwitch Pulse Length ≥ 20 msSwitching Current < 1 mAExternal Potentiometer Connection/Value Z1-Z2 / 50 kΩCable length to the remote potentiometer ≤ 80 ft (25 m) shielded, shield connected to Z2Time DelayRange 0.05 s ... 300 h in 10 RangesRecycle Time < 50 msRepeat Accuracy (constant parameters) < 0.2 %Time Delay vs Input Voltage Tolerance < 0.008% / % ∆ VTime Delay vs Temperature < 0.07% / °CDisplayInput Voltage/Timing U/T Green LED steady/flashing during timingOutput Relay Energized R1 & R2 2 Red LED'sOutput 15-16/18, 25(21)-26(22)/28(24) 2 Relays, SPDT isolated contacts in eachRating 4 A resistive @ 230 V AC (AC 12)
3 A inductive @ 230 V AC (AC 15)4 A resistive @ 24 V DC (DC 12)2 A inductive @ 24 V DC (DC 13)
Mechanical Life ≤ 30 x 106 operationsElectrical Life (4 A resistive @ 230 V AC) ≤ 1 x 105 operationsExternal Fuse for Contact Protection ≤ 10 A fast actingGeneralRated Impulse Withstand Voltage (Vimp) 4 kVOperating/Storage Temperature -25°C ... +65°C / -40°C ... +85°CMounting of DIN rail (EN 50022) Snap-on mounting/Screw mounting with adaptorWire size stranded with wire end ferrule 2 x 14 AWG (2 x 2.5 mm2)Accessories/Mechanical Outline See Accessory PagesDimensions (W x H x D) 0.89 x 3.07 x 3.93 in. (22.5 x 78 x 100 mm)Weight ≅ 5.3 oz (150 g)
Approvals:
External potentiometer 1SVR 701 800 R 1000Sealable transparent cover 1SVR 430 005 R 0100Adaptor for screw mounting 1SVR 430 029 R 0100
DescriptionOnly 22.5 mm wide, the CT-MFS multifunction timerreplaces many single function timers and reducesservice/maintenance cost and inventory. Thefunction, time range and actual time delay are allscrewdriver adjustable. Eight functions can beselected using a rotary switch, which displays aninternational symbol for every function; e.g. for“Delay on Make.” The 10 time ranges from 0.05 sto 300 h are also selected using a rotary switch onthe front of the unit. A desired time delay is thenselected using an onboard potentiometer with ascale. When an external potentiometer is connected,the on board potentiometer is automaticallydisabled. During the time delay, the green LEDflashes. Two red LED's indicate the internal relaysare energized. A switch is provided to program thesecond relay R2 for time delayed or instantaneousoperation.Screw Clamp
Connections
Accessories
Technical Data
Connecting an external potentiometer
Use shielded cableShield connected to Z2
Connecting control switches or contacts
Connecting a 3 wire, 24 V DC proximity switch as theinitiate (control) switch S1
S1 = Control Contact or Initiate SwitchS2 = Stop and Hold or Accumulative Timing Switch
External Potentiometer
External potentiometer with graduated dial supplied for22.5 mm (.886") panel cut-out.Degree of protection IP 65 (NEMA 5) fastened with alocking ring. 50 kΩ ±20%
P/N 1SVR 701 800 R 1000
10 Time Ranges Input Voltage Part Number
Part Number
Y1
Z2
Y1 L-
L+
Y1
X1A1Z1
15Z2 2521
252115A1
A2 16 18 2622
2824
262228241618 A2
Z2
24 V
DC
5
ABBMFS02E2RS 11.06.03
www.ssac.com
V = VoltageS1 = Initiate SwitchS2 = Stop and hold or
Accumulative TimingT = Complete Time Delayt = Incomplete Time Delayts = Closing S2 stops and
holds timing
R = ResetRLY1 = Relay 1RLY2 = Relay 2G = Green (LED)^ = The operation of Relay 2 is
switch selectable; instantaneous or time delayed= OFF, open, de-energized= ON, closed, energized
Legend
A
B
C
D
E
H
I
F
G
Settings
Timer Functions
Delay on Make
RLY2^ (inst.)
LEDS2
V
15/18 25/28
21/2421/22
A1-A2
Y1-Z2
t tT ts
RS1
Trailing Edge Single Shot
RLY1 & 2^
RLY2^ (inst.)
LEDS2
S1
V
15/18 25/28
21/2421/22
G
A1-A2
Y1-Z2
X1-Z2
Delay on Break
tT tts
RLY1 & 2^
LEDS2
S1
V
15/18 25/28
21/2421/22
G
A1-A2
Y1-Z2
15/16 25/26
X1-Z2
Recycle/Flasher, ON Time First
TT
R
15/18 25/28RLY1 & 2^
LED
V
21/2421/22
A1-A2
Y1-Z2
G
S1
Recycle/Flasher, OFF Time First
15/18 25/28RLY1 & 2^
LED
V
21/2421/22
A1-A2
Y1-Z2
G
S1
15/16 25/26
Interval
t tT ts
R
RLY1 & 2^
RLY2^ (inst.)
LEDS2
S1
V
15/18 25/28
21/2421/22
G
A1-A2
Y1-Z2
15/16 25/26
X1-Z2
X1-Z2G
15/16 25/26
Star-Delta Starting Twice Delayed on Operate
RLY1 & 2^
RLY2^ (inst.)
RLY2^ (inst.)
RLY2^ (inst.)
t tT ts
15/16 25/26
15/16 25/26
Motor Starting Functions
T1 = Adjustable Star (Wye) Start Time; T2 = fixed at ≅ 50 msStar = Wye Connection (starting); Delta = Delta Connection (running)
T2T1
V A1-A2
Star RLY1 15/18
Delta RLY2 25/2825/26
GLED
15/16
Star-Delta Starting With Wiper Function
LED
V
T2T1
A1-A2
15/18
25/2825/26
G
15/16
Multifunction TimerCT-MFS timetron®
Relay Output
Star RLY1
Delta RLY2
R 2 Red LED - Relay 2, SPDT(25/26, 25/28) or (21/22, 21/24)
Time Range Selector SwitchBTime Delay Adjustment
Function Selector SwitchD
KEYScrew terminals for up to2 X 14 AWG (2 x 2.5 mm2)
A
E
H
I
F
G U/T Green LED - Input voltage, timing
Switch R2 Relay from timed toinstantaneous contacts.Identification label
C
R 1 Red LED - Relay 1, SPDT(15/16, 15/18)
T
R
T
6
TRU01E2S 04.03.02
www.ssac.com
V = Voltage S1 = Initiate Switch R = ResetTD = Time Delay NO = Normally Open Contact
Panel mount kitP/N: BZ1
Hold down clipsP/Ns: PSC8 (NDS 8)
PSC11 (NDS 11)
11-pin socketP/N: NDS 11
Octal8-pin socketP/N: NDS 8
Approvals:
Accessories
See accessory pages for specifications.
Inches(Millimeters)
DescriptionThe TRU Series is a Universal Time Delay Relay.Both function and time range can be selected onthe top face of the unit. In addition tomultifunctioning and multiple time ranges, the TRUSeries features universal input voltage; 19 to 264V AC and 19 to 30 V DC. One unit, multifunction,multirange, universal voltage, and full 10 A output.The TRU Series can directly replace up to 1000competitive time delay relay models.
OperationA six position slide switch selects Delay on Make,Interval, Single Shot, Recycle (ON time first), Delayon Break, and Retriggerable Single Shot. 8-PinDPDT base wiring is limited to Delay on Make,Interval, and Recycle functions.
Multifunction, MultirangeTRU SeriesUniversal Time Delay Relay
Microcontroller +/-0.1% Repeat AccuracySix Timing Functions are Switch Selectable0.1 s ... 1000 m in Six RangesKnob Adjustable Time DelayUniversal Input Voltage 19...264 V AC & 19...30 V DC10 A, SPDT or DPDT Contacts
19 ... 264 V AC; 19 ... 30 V DC19 ... 264 V AC; 19 ... 30 V DC19 ... 264 V AC; 19 ... 30 V DC
8 pin DPDT 8 pin SPDT11 pin DPDT
366
TRU1TRU2TRU3
Part NumberFunctionsBase WiringVoltage
Technical DataTime DelayType Digital integrated circuitryRange (Dipswitch Selectable) 0.1 s ... 1000 m in 6 ranges--0.1 ... 10, 1 ... 100 or
10 ... 1000 s; 0.1 ... 10, 1 ... 100 or 10 ... 1000 mAdjustments Multiplier: 4 position dipswitch selects x0.1, x1,
x10, and s or mTime Setting: Onboard knob adjustment
with 1 ... 100 reference dialModes of Operation A six position slide switch selects Delay on
Make, Interval, Single Shot, Recycle (ON timefirst), Delay on Break, and Retriggerable Single
Shot. 8 pin DPDT base wiring is limited toDelay on Make, Interval, and Recycle functions.
LED Indication Two LED's indicate input power applied & output relay status
Repeat Accuracy +/-0.1%, or +/-16 ms, whichever is greaterRecycle Time ≤ 300 msTime Delay vs. Temperature & Voltage +/-2%InputVoltage--Universal Input Range 19 ... 264 V AC and 19 ... 30 V DCLine Frequency 50 ... 60 HzOutputType Electromechanical relayForm SPDT & DPDT versions availableRating 10 A resistive at 240 V AC; 7 A inductive at 120 V ACLife Mechanical: 1 x 107; Full Load: 1 x 106
ProtectionTransient 38 joulesIsolation Voltage ≥ 1500 V RMS input to outputPolarity DC units are reverse polarity protectedMechanicalMounting Plug-in socketPackage 3.44 x 2.39 x 1.78 in. (87.4 x 60.7 x 45.2 mm)Termination Octal plug (8 Pin) or magnal plug (11 Pin)EnvironmentalOperating Temperature -20°C ... +65°CStorage Temperature -30°C ... +85°CWeight ≅ 6 oz (170 g)
Delay On MakeIntervalRecycle
Delay On MakeIntervalRecycle
Single ShotRetriggerable Single Shot
11 pin DPDT
Relay contacts are isolated. Dashed lines areinternal connections.
8 pin SPDT
8 pin DPDT
7
ABBMFD01E2S 11.06.03
Millimeters
In 22.5 mm width P/N 1SVR 430 029 R 0100
5
58
43,4
70
17,5
45
S1 not used for Delay on Make, Interval,and Recycle/Flasher Functions
Mechanical
5 5.0 ... 100 m6 0.5 ... 10 h7 5.0 ... 100 h
17.5 mm Wide, 35 mm DIN MountingUniversal Voltage 24 ... 240 V AC; 24...48 V DC7 Time Ranges From 0.05 ... 100 hFunction and Time Range Selectable7 Functions: Delay on Make, Delay on Break,
Interval, Recycle/Flasher, Single ShotTrailing Edge Interval
Multifunction TimerCT-MFDRelay Output
Description
Repeat Accuracy < +/- 0.5%
24 ... 240 V AC; 24...48 V DC
7 Time Ranges
InputVoltage/Power Consumption A1-A2 24 ... 240 V AC; 24...48 V DC/ 2.0 VA / WTolerance -15% ... +10%Frequency DC or 50 ... 60 HzInitiate Time ≥ 20 msTime DelayRange 0.05 s ... 100 h in 7 rangesReset Time < 50 msRepeat Accuracy ≤ +/- 0.5%Time Delay vs Input Voltage Tolerance ≤ 0.5%Time Delay vs Temperature ≤ 0.06%/°COutput 15-16/18 Isolated SPDT RelayRated Voltage VDE 0100, IEC947-1 250 VRating 4 A resistive @ 230 V AC (AC 12)
3 A inductive @ 230 V AC (AC 15) 4 A resistive @ 24 V DC (DC 12)
2 A inductive @ 24 V DC (DC 13)Switching Voltage ≤ 240 V ACMechanical Life ≤ 30 x 106 operationsElectrical Life (4A resistive @ 230 V AC) ≤ 1 x 105 operationsExternal Fuse For (NO) Contact Protection ≤ 10 A fast actingGeneralRated Impulse Withstand Voltage (Vimp) 4 kV/1.2 50 mSOperating/Storage Temperature -20°C ... +60°C / -40°C ... +85°CMounting on DIN Rail (EN 50022) Snap-on mounting/Screw mounting with adaptorWire Size Stranded with Wire End Ferrule 2 x 14 AWG (2 x 2.5 mm2)Weight ≅ 2.1 oz (60 g)Dimensions (W x H x D) 0.69 x 2.76 x 2.48 in. (17.5 x 70 x 63 mm)
Screw ClampConnections
Approvals:
Input Voltage Part Number
1SVR 500 020 R 0000
Technical Data
Legend
Delay on Make
tT
V
NO 15/18
A1-A2
A1-Y1
15/16
Delay on Break
T
V
NO 15/18
A1-A2
A1-Y1
15/16
S1
NC
Interval
V
NO 15/18
A1-A2
A1-Y1
15/16NC
Single Shot
T T
V
NO
S1
15/18
A1-A2
A1-Y1
Recycle/Flasher
V
NO 15/18
A1-A2
A1-Y1
15/16NC
ON First OFF First
The CT-MFD Series is a cost effective, 17.5mmwide DIN 3 mountable multifunction timer.Onboard adjustable delays from 0.05 s to 100 hare available in 7 ranges. The repeat accuracyis less than +/-0.5%. The green LED lights whenpower is applied and the red LED lights whenthe output relay energizes. The isolated SPDTrelay contacts are rated 4 A resistive. An untimedload may be connected to S1.
V = Voltage S1 = Initiate Switch NO = Normally Open NC = Normally Closed T = Complete Time Delay t = Incomplete Time Delay UTL = Untimed Load
= OFF, open, de-energized= ON, closed, energized
1 0.05 ... 1 s2 0.5 ... 10 s3 5.0 ... 100 s4 0.5 ... 10 m
15/16NC
Accessories
Screw Mounting Adaptor
www.ssac.com
NC
V A1-A2
A1-Y1S1
NO 15/1815/16NC
New Product A
vaila
ble January
2004
Trailing Edge Interval
T t
TT TT
8
ABB
24 V AC/DC / 110... 240 V AC24 V, 42 ... 48 V AC/DC110 ... 240 V AC
ERS01E2S 10.28.03
www.ssac.com
1SVR 430 103 R 0200
1SVR 430 102 R 0100
T T
R RR
Potentiometer
L1/L+
A1Z1
Z2
50 k
2521
15
26222824
A2
1618
N/L-
Z2
Z1Z2
Z2Z1252115
A1
A2
16 18 2622
2824
Delay on Make TimerCT-ERS timetron®
Relay Output
InputVoltage/Power Consumption A1-A2 12 ... 40 V AC / ≅ 0.5 ... 1 VA
A1-A2 12 ... 60 V DC / ≅ 0.5 ... 1 WA1-A2 110 ... 240 V AC / ≅ 2.5 ... 12 VA
Tolerance -15 % ... +10 %Frequency 50 ... 60 HzDuty Cycle 100 %External Potentiometer Connection/Value Z1-Z2 / 50 kΩCable Length to the Remote Potentiometer ≤ 80 ft (25 m) shielded, shield connected to Z2Time DelayRange 0.05 s ... 300 h in 10 RangesReset Time < 50 msRepeat Accuracy < 0.2 %Time Delay vs. Input Voltage Tolerance < 0.008 % / % ∆VTime Delay vs. Temperature < 0.07 % / °CDisplay of Operational StatusInput Voltage/Timer Green LED steady / flashing while timingOutput Relay(s) Energized R1 (R2) Red LED(s)Output 25-26/28, 15-16/18 1 or 2 Relays, SPDT isolated contacts in eachRated Voltage VDE 0110, IEC 947-1 250 VSwitching Voltage 250 V ACRating 4 A resistive @ 230 V AC (AC 12)
3 A inductive @ 230 V AC (AC 15) 4 A resistive @ 24 V DC (DC 12)
2 A inductive @ 24 V DC (DC 13)Mechanical Life 30 x 106 operationsElectrical Life (4 A resistive @ 230 V AC) 1 x 105 operationsExternal Fuse for Contacts ≤ 10 A fast acting fuseGeneralRated Impulse Withstand Voltage (Vimp) 4 kVOperating/Storage Temperature -25°C ... +65°C / -40°C ... +85°CMounting of DIN Rail (EN 50022) Snap-on mounting/Screw mounting with adaptorWire size stranded with wire end ferrules 2 x 14 AWG (2 x 2.5 mm2)Weight ≅ 5.3 oz (150 g)Dimensions (W x H x D) .89 x 3.07 x 3.94 in. (22.5 x 78 x 100 mm)Accessories/Mechanical Outline See Accessories page
Approvals:
22.5 mm Wide, DIN 3 Mounting0.05 s ... 300 h in 10 Ranges1 or 2 SPDT Relay Outputs2 or 3 LED Indicators24 V AC/DC ... 240 V AC in 2 Ranges
Delay on Make
DescriptionThe CT-ERS is an accurate, 22.5 mm, delay on maketimer that mounts on 35mm DIN Rail. It is availablewith an isolated SPDT time delay relay output, andwith an (optional) second SPDT timed or instantaneousrelay. The time delay can be adjusted on the unit orexternally.OperationAll modelsUpon application of input voltage to the A1 and A2terminals, the time delay begins and the green LEDflashes. The output relay is de-energized before andduring the time delay. At the end of the delay, theoutput relays energizes and both LEDs glow steadily.Removing input voltage resets the time delay andoutput relay.Additional operation for P/N 1SVR 430 103 R 0200:If the selector switch is set to the InstantaneousPosition, the second SPDT relay (RLY2) energizesinstantaneously when voltage is applied. If the selectorswitch is not in the Instantaneous Position, theoperation of the second relay is the same as the first.Removing input voltage de-energizes both relays.External adjustment of the time delay is possible byconnecting a potentiometer to terminals Z1 and Z2,which disables the internal potentiometer.
10 Time Ranges
1 0.05 - 1 s* 6 15.0 - 300 s2 0.15 - 3 s* 7 1.50 - 30 m3 0.50 - 10 s 8 15.0 - 300 m4 1.50 - 30 s 9 1.50 - 30 h5 5.00 - 100 s 10 15.0 - 300 h
* Green LED does not flash during timing.
Sealable transparent coverAdaptor for screw mountingExternal Potentiometer
Technical Data
Input Voltage Part Number
Accessories Part Number RLY1 & 2^
V
15/18 25/28
21/24
15/16 25/26
A1-A2
21/22
GLED
RLY 2^ (inst)
V = Voltage T = Complete Time Delay t = Incomplete Time Delay R = ResetRLY1 = Relay 1RLY2 = Relay 2 G = Green (LED) ^ =
= OFF, open, de-energized= ON, closed, energized
Legend
Screw ClampConnections
External Potentiometer
External potentiometer with graduated dial supplied for22.5 mm (.886") panel cut-out.Degree of protection IP 65 (NEMA 5) fastened with alocking ring. 50 kΩ ±20%
P/N 1SVR 701 800 R 1000
Connection forP/N 1SVR 430 103 R 0200
Connection forP/N 1SVR 430 102 R 0100
P/N 1SVR 430 103 R 0200 The operation of Relay 2 is switch selectable;instantaneous or time delayed
Millimeters, Inches
1SVR 430 005 R 01001SVR 430 029 R 01001SVR 701 800 R 1000
V
A1
15
A2
1618
15
A1
A2
1618
-+
9
ABBERD01E2S 11.06.03
Delay on Make TimerCT-ERDRelay Output
DescriptionThe CT-ERD Series is a cost effective, 17.5mmwide DIN 3 mountable Delay on Make timer.Onboard adjustable delays from 0.05 s to 100 hare available in 7 ranges. The repeat accuracyis less than +/-0.5%. The green LED lights whenpower is applied and the red LED lights whenthe output relay energizes. The isolated SPDTrelay contacts are rated 4 A resistive.
OperationUpon application of input voltage, the time delaybegins. The output relay is de-energized beforeand during the time delay. At the end of the timedelay, the output relay energizes and remainsenergized until input voltage is removed.RESET: Removing input voltage resets the timedelay and output.
Delay on Make7 Time Ranges
Approvals:
InputVoltage/Power Consumption A1-A2 24 ... 240 V AC; 24 ... 48 V DC/ ≅ 2.0 VA/WTolerance -15 % ... +10 %Frequency DC or 50 ... 60 HzTime DelayRange 0.05 s ... 100 h in 7 RangesRecycle Time ≤ 50 msRepeat Accuracy +/- 0.5%Time Delay vs Input Voltage Tolerance ≤ 0.5%Time Delay vs Temperature ≤ 0.06%/°CStatus DisplaySupply Voltage LED greenOutput Relay Energized LED redOutput 15-16/18 Isolated Relay Contact, SPDTRated Voltage VDE 0100, IEC947-1 250 VRating 4 A resistive @ 230 V AC (AC 12)
3 A inductive @ 230 V AC (AC 15)4 A resistive @ 24 V DC (DC 12)2 A inductive @ 24 V DC (DC 13)
Switching Voltage ≤ 240 V ACMechanical Life ≤ 30 x 106 operationsElectrical Life (4A resistive @ 230 V AC) ≤ 1 x 105 operationsExternal Fuse For (NO) Contact Protection ≤ 10 A fast actingGeneralRated Impulse Withstand Voltage (Vimp) 4 kV/1.2 - 50 mSOperating/Storage Temperature -20°C ... +60°C / -40°C ... +85°CMounting on DIN Rail (EN 50022) Snap-on mounting/Screw mounting with adaptorWire Size Stranded with Wire End Ferrules 2 x 14 AWG (2 x 2.5 mm2)Weight ≅ 2.1 oz (60 g)Dimensions (W x H x D) 0.69 x 2.76 x 2.48 in (17.5 x 70 x 63 mm)
17.5 mm Wide, DIN Mounting0.05 s ... 100 h in 7 RangesRepeat Accuracy < +/-0.5%4 A Isolated SPDT Relay Output2 LED's To Indicate Operational Status24 ... 240 V AC; 24 ... 48 V DC
V A1-A2
15/18NO
Part Number
Screw ClampConnections
T t
15/16
Legend V = Voltage NO = Normally Open NC = Normally Closed T = Complete Time Delay t = Incomplete Time Delay
Technical Data
Input Voltage
In 22.5 mm width P/N 1SVR 430 029 R 0100
Millimeters, Inches
Accessories
= OFF, open, de-energized= ON, closed, energized
Screw Mounting Adaptor
www.ssac.com
24 ... 240 V AC; 24 ... 48 V DC1 0.05 ... 1 s2 0.5 ... 10 s3 5.0 ... 100 s4 0.5 ... 10 m
5 5.0 ... 100 m6 0.5 ... 10 h7 5.0 ... 100 h
1SVR 500 100 R 0000
5
58
43,4
70
17,5
45
New Product A
vaila
ble January
2004
NC
Mechanical
10
TD001E2S 10.24.03
TDM & TDI +/– 0.1% or +/– 8.3 ms, whichever is greater TDS & TDB +/– 0.1% +/– 2% or 50 ms, whichever is greater < 50 ms TDMH < 500 ms TDI, TDS & TDB < 150 ms
TDS & TDB - 60 ms+/– 2 %
TDM < 2.25 Watts max. TDI, TDS & TDB < 3.25 Watts 10A resistive at 28 V DC & 240 V AC 1/3 hp at 120 & 240 V AC
1 x 107 operations / 1 x 106 operations LED glows during timing LED glows during timing and indicates relay energized
8-Pin Octal plug 8-Pin Octal plug or 11-Pin Magnal plug-20°C to +65°C / -30°C to +85°C
Inches (Millimeters)
TDB24DL BTDB24AL BTDBL120AL BTDBL120ALD CTDB120AL BTDB120ALD CTDBH120AL B
TDS24DL BTDS24AL BTDSL120AL BTDSL120ALD CTDS120AL BTDS120ALD CTDSH120AL B
TDI24DL ATDI24AL ATDIL120AL A
TDI120AL A
TDIH120AL A
TDML12DL ATDM12DL ATDML24DL ATDM24DL ATDM24AL ATDML120AL A
TDM120AL A
TDMH120AL A
SingleShot
Delay OnMake
0.1 ... 102.3 s1 ... 1023 s
0.1 ... 102.3 s1 ... 1023 s1 ... 1023 s
0.1 ... 102.3 s0.1 ... 102.3 s
1 ... 1023 s1 ... 1023 s
10 ...10230 s
Diagram
Repeat AccuracySetting AccuracyReset TimeRecycle TimeInitiate TimeTime Delay vs. Temperature and VoltageInput : - Power ConsumptionOutput : - Rating - Life : Mechanical / Full Load - Status indicationTerminationOperating Temperature / Storage Temperature
Time Diagrams
TDI...Interval
TDM...TDM, TDI, TDS, TDB SeriesDigi-SetTime Delay Relay
Specifications
24 V AC
120 V AC
TDS... TDB...
+20% -15%
+20% -15%
12 V DC
24 V DC
Panel mount kitP/N: BZ1
Hold down clipsP/N: PSC8 (NDS 8) PSC11 (NDS 11)
11-PinsocketP/N: NDS 11
Octal8-Pin socketP/N: NDS 8
Diagram Interval Delay OnBreak
A B
C
Diagram
50 ... 60 Hz
+10% -20%50 ... 60 Hz
*Dash Lines Are Internal Connections. Relay Contacts Are Isolated.
Diagram
Call for 230 V AC, 110 V DC and combinations not listed
S1
See accessory pages for specifications.
The TD Series of time delay relays arecomprised of digital circuitry and a separateoscillator to provide high accuracy and stability.The delay is selected by means of ten binaryswitches, which allow the setting of the desireddelay the first time and every time. Full 10ampere isolated output contacts.
Delay On Make Single Shot Delay On Break
Accessories
VoltageToleranceFrequency Time Range
V = Voltage S1 = Initiate Switch NO = Normally Open Contact NC = Normally Closed Contact TD = Time Delay R = Reset = Undefined Time
Part Numbers
Delay On Make Interval Single Shot Delay On Break
Mechanical
8-Pin Octal DPDT* 8-Pin Octal SPDT*
11-Pin DPDT*Part Numbers
**
** TDM, TDS, TDB 8 pin models used in combination with P1011 6 socket only
Switch Setable Time Delays+/-0.1% Repeat AccuracyDelays from 100 ms ... 2.8 h in 3 RangesAC and DC Input VoltagesIsolated 10 A Relay ContactsPlug-In Connection - LED Indication
www.ssac.com
Digi-Set Binary Switch Operation
11
TDR01E2S 10.14.03
www.ssac.com
Recycling (Pulse Generator)TDR Digi-SetTime Delay Relay
Switch Setable Time Delays - Both Times Adjustable0.1 s ... 2.8 h in 3 RangesDigital Circuitry +/-0.1% Repeat Accuracy10 A DPDT Isolated Relay ContactsOctal Plug-in Base Connection
DescriptionThe TDR Series of time delay relays arecomprised of digital circuitry and a separateoscillator to provide high accuracy and stability.The ON and OFF delays are selected by meansof ten binary switches, which allow the setting ofthe desired delay the first time and every time.Full 10 A isolated DPDT output contacts.
OperationUpon application of input voltage, the output relayis energized and the ON time begins. At the endof the ON time, the output de-energizes and theOFF time begins. At the end of the OFF time, theoutput relay is energized and the cycle repeatsas long as input voltage is applied. The OFF timemay be the first delay in recycling timers.Reset: Removing input voltage resets the outputand time delays, and returns the sequence to thefirst delay.
Approvals:
Time DelayType Digital integrated circuitryRange** 0.1 ... 102.3 s in 0.1 s increments
1 ... 1023 s in 1 s increments 10 ... 10,230 s in 10 s increments
Repeat Accuracy +/-0.1%Setting Accuracy +/-2%Reset Time ≤ 150 msRecycle Time ≤ 500 msTime Delay vs. Temperature & Voltage +/-5%InputVoltage 120 V ACTolerance 12 V DC & 24 V DC/AC -15% ... + 20%
110 ... 230 V AC/DC -20% ... +10%Line Frequency 50 ... 60 HzOutputType Electromechanical relayForm Double pole double throw (DPDT)Rating 10 A resistive, 1/3 Hp at 240 V ACLife Mechanical -- 1 x107
Full Load -- 1 x 106
ProtectionIsolation Voltage ≥ 1500 V RMS input to outputMechanicalMounting Plug-in socketPackage 3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm)Termination Octal plug (8 Pin)EnvironmentalOperating Temperature -20°C ... +60°CStorage Temperature -30°C ... +85°CWeight ≅ 6 oz (170 g)
**For CE approved applications, power must be removed from the unit when a switch positionis changed.
Relay contacts are isolated. Dashed lines areinternal connections.
V = Voltage R = Reset T1 = ON TimeT2 = OFF Time NO = Normally OpenNC = Normally Closed
Recycling (ON First)
Accessories
Panel mount kitP/N: BZ1
Octal8-pin socketP/N: NDS 8
See accessory pages for specifications.
DIN railP/N: C103PM
Hold down clipsP/N: PSC8
Inches (Millimeters)
Input Voltage ON Time Range OFF Time Range Part Number
Also Available in 12, 24, 110 V DC & 24, 230 V ACOther Time Range Combinations are Available
First Delay120 V AC120 V AC120 V AC
0.1 ... 102.3 s 1 ... 1023 s 10 ... 10230 s
0.1 ... 102.3 s 1 ... 1023 s 10 ... 10230 s
TDR4A11 TDR4A22 TDR4A33
ON TimeON TimeON Time
Technical Data
Digi-Set Binary Switch Operation
12
ABBMKE01E2S 10.10.03
www.ssac.com
24 ... 240 V AC/DC0.1 ... 10 s 3 ... 300 s
Approvals:
InputVoltage 24 ... 240 V AC/DCTolerance -15% ... +10%Frequency 50 ... 60 HzVoltage Drop (A1/A2) ≤ 3 VPower Consumption/Leakage Current ≤≤≤≤≤ 2 mA (24 ... 60 V AC/DC)
≤≤≤≤≤ 8 mA (60 ... 240 V AC/DC)Time DelayRanges 0.1 ... 10 s 3 ... 300 sRecycle Time ≤ 100 msRepeat Accuracy ≤ 1.0 %Time Delay vs Input Voltage Tolerance ≤ 0.5%Time Delay vs Temperature ≤ 0.1%/°CDisplaySingle LED Red LED glows during timingOutput Solid StateLoad Current 20 mA ... 0.8 A at 20°CLoad Current Derating 10 mA/°CSurge Current ≤ 20 A for t ≤ 20 msMaximum Cable LengthBetween MKE & Connected Load at 24 V AC = 220 m/22 nFat 50/60 Hz and a cable capacity of 100 pF/m: at 42 V AC = 100 m/10 nF
at 60 V AC = 65 m/6.5 nFat 110 V AC = 50 m/5.0 nFat 240 V AC = 22 m/2.2 nF
GeneralOperating/Storage Temperature -20°C ... +60°C / -40°C ... +85°CMounting on DIN rail (EN 50022) Snap-on mounting/Screw mounting with adaptorWire Size (stranded with wire end ferrule) 2 x 16 AWG (2 x 1.5 mm2)Weight ≅ 2.8 oz (80 g)Dimensions (W x H x D) 0.89 x 3.07 x 3.09 in. (22.5 x 78 x 78.5 mm)
See accessory pages for a Dimensional ViewAccessories See Accessories page
4 Functions0.8 A Solid State OutputUniversal Voltage 24 ... 240 V AC/DCKnob Adjustable 0.1... 300 s in 2 RangesFunction and time range selection by wiring externaljumpers1 LED Indicator
Screw ClampConnections
The CT-MKE is a totally solid state timer. It isconnected in series with the load, contactor, orrelay coil. Functions and time ranges areprogrammed via external jumper wires. The timedelay is adjustable via an onboard knurledthumb wheel. Time delays from 0.1 ... 300 s in 2ranges are available with 1% repeat accuracy.The red LED glows during timing.
L
V
A1 X1 X2
A2X4X3
L
V
A1 X1 X2
A2X4X3
L
V
A1 X1 X2
A2X4X3
A1
A2
Time Delay Range 0.1 ... 10 s (as shown)Remove Jumper X3 to X4 for 3 ... 300 s
Delay On Make(0.1 ... 10 s)
Interval(3 ... 300 s)
Recycle/Flasher(3 ... 300 s)
Input Voltage
IntervalExternal connection X1-X4 required. Uponapplication of input voltage, the time delay begins.The output energizes during the time delay. At theend of time delay, the output de-energizes andremains de-energized as long as input voltage isapplied.Reset: Removing input voltage resets the timedelay and the output.
Recycle/Flasher (ON Time First)External connection X1-X4 and X1-X2 required.Upon application of input voltage, the outputenergizes and the ON time begins. At the end ofthe ON time, the output de-energizes and the OFFtime begins. At the end of the OFF time, the outputenergizes and the cycle repeats as long as inputvoltage is applied.Recycle/Flasher (OFF Time First)External connection X2-X4 required. Uponapplication of input voltage, the OFF time is firstfollowed by the ON time as described above.(See diagram below).Recycle/Flasher Reset: Removing input voltageresets the output and time delays, and returnsthe sequence to the first delay.
V = VoltageL = LoadT = Complete Time Delay t = Incomplete Time DelayR = Reset
= OFF, open, de-energized= ON, closed, energized
Interval
T t
RR
A1
A2
V
L
ON Time First (as shown)OFF Time First - Remove Jumper X1 to X2
Delay on Make
Delay on MakeNo external jumpers required. Upon applicationof input voltage, the time delay begins. The outputis de-energized before and during the time delay.At the end of the time delay, the output energizesand remains energized until input voltage isremoved. Reset: Removing input voltage resetsthe time delay and output.
T t
RRA1
A2
V
L
Recycle/Flasher, "OFF" Time First
A1
A2
V
LT T
R
Recycle/Flasher, "ON" Time First
A1
A2
V
LT T
R
Part NumberTime Range
1SVR 550 019 R 0000
Multifunction TimerCT-MKE timetron®
Solid State Output
Description
Operation
Technical Data
Legend
13
ASDS1E2S 03.29.02
ASQU, ASTU, DSQU, DSTU SeriesMicroTimeTiming Modules
≤2.41(61.2)
≤3.00(76.2)
A1 B1
18 A2
0.1 1 23
456
78910
B1A1
18 A2
18A1A2B1
(17.52)≤.69
18A1A2B1
0.1 1 23
456
78910
Specifications ASQU/ASTU DSQU/DSTUMicrocontroller based circuitry
Adjustment knob with dial 6 switches select the time delay0.1 s ... 100 m in 4 ranges 0.1 s ... 63 m in 4 ranges
+/–1% or 50 ms whichever is greater +/– 0.1% or 16 ms whichever is greater2 switches select 1 of 4 multipliers
2 switches select Delay On Make, Interval, Single Shot, Recycling, or Delay On Break24 ... 240 V AC -20%, +10% 9 ... 110 V DC, -0%, +20%
0.7A steady state, 10A inrush-40°C ... +60°C/-40°C ... +85°C
≅ 4.2 oz (119 g)
NOTE: For CE approved applications, power must be removed from the unit when a switch positionis changed.
ASQU0.25 (6.35) Male Quick Connects
5mm IP20Push-on Terminal Blocks
≤14 AWG (2.45mm2)
ASTU DSQU DSTU
Snap ForMounting
Bases
Inches (Millimeters)
0.1...10s
1...100s
10...1000s
1...100m
X100s
X10s
X1s
X10m
R M S
DC
DC
DC
DC
FE
FE
FE
FE
0.1s
1s
10s
1m
0.1 ... 6.3s
1 ... 63s
10 ... 630s
1 ... 63m
X10s
X1s
X0.1s
X1m
R M S I
DC
DC
DC
DC
FE
FE
FE
FE
12481632
ON
ASQU/ASTU DSQU/DSTU
DOM = Delay On MakeSS = Single Shot/IntervalR = RecyclingDOB = Delay On Break
Knob 9 ... 110 V DC Quick Connects ASQUD3Knob 9 ... 110 V DC Terminal Blocks ASTUD3Knob 24 ... 240 V AC Quick Connects ASQUA3Knob 24 ... 240 V AC Terminal Blocks ASTUA3
Switches 9 ... 110 V DC Quick Connects DSQUD3Switches 9 ... 110 V DC Terminal Blocks DSTUD3Switches 24 ... 240 V AC Quick Connects DSQUA3Switches 24 ... 240 V AC Terminal Blocks DSTUA3
Both - Surface andDIN Rail Adaptors,with Quick MountFasteners.
Call for other baseadaptor options.
R = RangeM = Multiplier
S = SettingI = Increments of Time
DSQU/DSTUTime Delay Adjustment
Add switchesin ON Position
TD=2+8+16=26
Adjustment Voltage Connection Part Number Base Adaptors
Knob
Switch
Mechanical
The MicroTime microcontroller based encapsulated timers offer multiple timing functions,voltages, and time delay ranges all in one unit. Five timing functions are selected via onboardswitches located on top of the unit. Time delay is selected via 6 switches or knob adjustment.Universal input voltage range can be ordered for AC or DC operation without jumpers orrewiring. Both models may be ordered with quick connects or push-on terminal blocks. Bothcan be surface mounted or rail mounted depending on the snap-on base adaptor selected.
Mounting Bases
V = VoltageL = LoadJ = Wiring for Interval
OperationUTL = Untimed LoadS1 = Initiate SwitchTD = Time DelayR = Reset
Function Selection
TypeAdjustmentTime Delay RangesRepeat AccuracyRange MultipliersTiming FunctionsInput VoltageOutputOperating/Storage TemperatureWeight
Range Selection
Inches (Millimeters)
Quick MountFastener (2)[Drill .187 (4.75)diameter hole]
DIN Rail Mount Surface MountUP
17.5 mm Package for High Rail DensityMultifunction - 5 Selectable Timing FunctionsMultirange - Knob or Switch Adjust from 0.1 s...100 mMultivoltage - 24 ... 240 V AC or 9 ... 110 V DC0.7 A Steady, 10 A Inrush Rated Solid State OutputTotally Solid State - Encapsulated
www.ssac.com
14
TDU01E2S 10.14.03
Also Available for 277 V AC
3 Universal Voltage Ranges From 24 ... 240 V AC/DCDigital Integrated CircuitrySwitch Selectable Delays From 0.1 s ... 2.8 hin 3 Ranges+/-0.5% Repeat Accuracy1 A Steady - 10 A InrushTotally Solid State and Encapsulated
Time DelayType Digital integrated circuitryRange* 0.1 ... 102.3 s in 0.1 s increments
1 ... 1023 s in 1 s increments10 ... 10230 s in 10 s increments
Repeat Accuracy +/-0.5%Tolerance (Factory Calibration) +/-10%Recycle Time 150 msTime Delay vs. Temperature & Voltage +/-5%InputVoltage 24 ... 120 V AC/DC
100 ... 240 V AC/DCLine Frequency 50 ... 60 HzTolerance +/-20%OutputType Solid stateForm Normally Open, open during timingMaximum Load Current 1 A steady state, 10 A inrush at 60°CMinimum Holding Current 40 mA for 24 ... 120 V & 100 ... 240 V modelsVoltage Drop ≅ 2.5 V at 1 AProtectionCircuitry EncapsulatedDielectric Breakdown ≥ 2000 V RMS terminals to mounting surfaceInsulation Resistance ≥100 MΩMechanicalMounting Surface mount with one #10 (M5 x 0.8) screwPackage 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)Termination 0.25 in. (6.35 mm) male quick connect terminalsEnvironmentalOperating Temperature -40°C ... +60°CStorage Temperature -40°C ... +85°CHumidity 95% relative, non-condensingWeight ≅ 2.4 oz (68 g)
DescriptionThe TDU Series is an encapsulated solid statedelay-on-make timer that combines digitaltiming circuitry with universal voltage operation.DIP switch adjustment allows accurate selectionof the time delay over the full time delay range.The TDU Series is an excellent choice forprocess control systems and OEM equipment.
OperationUpon application of input voltage, the time delaybegins. The output is de-energized before andduring the time delay. At the end of the timedelay, the output is energized and remainsenergized until input voltage is removed.Reset: Removing input voltage resets the timedelay and output.
Delay On Make (Operate)TDU Digi-SetTiming Module
Approvals:
Time Range - Seconds Part NumberInput Voltage Range - AC/DC
* For CE approved applications, power must be removed from the unit when a switch position is changed.
Load may be connected to terminal 3 or 1.
V = Voltage R = Reset TD = Time DelayL = Load = Undefined time
Inches (Millimeters)
Delay On Make
Accessories
See accessory pages for specifications.
DIN rail P/Ns: 17322005 (Steel)
DIN rail adaptorP/N: P1023 20
→←
Femalequickconnect
P/N: P1015 64 (AWG 14/16)
MountingbracketP/N: P1023 6
Quickconnect toscrew adaptorP/N: P1015 18
C103PM (Al)
24 ... 120100 ... 240 24 ... 120100 ... 240 24 ... 120100 ... 240
0.1 ... 102.30.1 ... 102.3 1 ... 1023 1 ... 1023 10 ... 10230 10 ... 10230
TDUL3000A TDUL3001A TDU3000A TDU3001A TDUH3000A TDUH3001A
Technical Data
www.ssac.com
Digi-Set Binary Switch Operation
15
TMV01E2S 03.27.02
www.ssac.com
A
B
Delay On Make (Operate)TMV8000/TSU2000 Uni-TimerTiming Module
Operates From 24 ... 240 V AC/DCKnob or Ext. Adjust Time DelaysDelays from 0.1 ... 8 mTotally Solid State - Encapsulated1 A Steady - 10 A InrushTwo Terminal Series Connection with Load
DescriptionUNI-TIMER is truly the universal timer. Two modelscover all the popular voltages and time delays.Available with knob or external adjust time delay.Its simple two terminals can easily be connectedin series with a relay coil, contactor coil, solenoid,lamps, small motor, etc., to delay their energization.
OperationUpon application of input voltage, the time delaybegins. The output is de-energized before andduring the time delay. At the end of the time delay,the output is energized and remains energized untilinput voltage is removed.Reset: Removing input voltage resets the timedelay and output.
Approvals:
Time DelayType Analog circuitryRange 5 ... 480 s (TSU2000)
0.1 ... 8 m (TMV8000)Repeat Accuracy +/-2%Tolerance (Factory Calibration) ≤ +/-10%Recycle Time ≤ 100 msInputVoltage 24 ... 240 V AC/DC +/-20%Line Frequency 50 ... 60 HzOutputType Solid stateForm Normally Open, open during timingMaximum Load Current 1 A steady state, 10 A inrush at 55°CMinimum Holding Current ≤ 40 mAVoltage Drop ≅ 2.5 V at 1 AProtectionCircuitry EncapsulatedDielectric Breakdown ≥ 2000 V RMS terminals to mounting surfaceInsulation Resistance ≥ 100 MΩMechanicalMounting Surface mount with one #10 (M5 x 0.8) screwPackage 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)Termination 0.25 in. (6.35 mm) male quick connect terminalsEnvironmentalOperating Temperature -20°C ... +70°CStorage Temperature -30°C ... +85°CHumidity 95% relative, non-condensingWeight ≅ 2.4 oz (68 g)
Part NumberInput Time Delay Adjustment
ExternalKnob
Load may be connected to terminal 3 or 1.TMV has knob adjustment.TSU has external adjustment terminals 4 & 5.
Inches (Millimeters)
Delay On Make
For illustration
Accessories
See accessory pages for specifications.
FemalequickconnectP/N:P1015 64 (AWG 14/16)
Versa-knobP/N: P0700 7
MountingbracketP/N: P1023 6
Quickconnect toscrew adaptorP/N: P1015 18
External adjustpotentiometerP/Ns:P1004 12 (fig A)P1004 12X (fig B)
DIN rail adaptorP/N: P1023 20
→←
Plug-onadjustmentmoduleP/N:VTP4S
17322005 (Steel)
DIN rail P/Ns:C103PM (Al)
V = Voltage L = Load R = ResetTD = Time Delay = Undefined time
TMV has the knob and dial.TSU has terminals 4 & 5.
Technical Data
24 ... 240 V AC/DC24 ... 240 V AC/DC
5 ... 480 s0.1 ... 8 m
TSU2000TMV8000
*When selecting an externalRT add at least 20% fortolerance of unit and the RT
16
TS001E2S 10.13.03
TSB421TSB422TSB423TSB424
TS2 TSS
0.05 ... 3 s0.5 ... 60 s
2 ... 180 s5 ... 600 s
VTP4B P100412XVTP4F P100412XVTP4J P100412XVTP5N P100413X
3 MΩ +/– 10%3 MΩ +/– 10%3 MΩ +/– 10%5 MΩ +/– 10%
VTP4B P100412XVTP4F P100412XVTP4J P100412XVTP5N P100413X
VTR4B P100412XVTR4F P100412XVTR4J P100412XVTR5N P100413X
TSB
VTR4B P100412XVTR4F P100412XVTR4J P100412XVTR5N P100413X
For illustration
TS1
TSS421TSS422TSS423TSS424
TS2421TS2422TS2423TS2424
TS1421TS1422TS1423TS1424
1S/1 MΩ20S/1 MΩ60S/1 MΩ
120S/1 MΩ
0.05 ... 3 s0.5 ... 60 s
2 ... 180 s5 ... 600 s
120 VAC50/60 Hz+/–20%
TS1, TS2, TSS, TSB SeriesVersa-TimerTiming Modules
VTP Versa-PotTime Range Max RT Value VTP Versa-Pot VTR Versa-Pot VTR Versa-Pot
Versa-timers offer proven reliability and perfor-mance with years of use in industrial and commer-cial applications. Analog circuitry and high volumeproduction techniques make this series veryaffordable. All versa-timers have two terminals forexternal adjustment.
P/NRT Value P/N P/N P/N
Delay On Make Interval Single Shot
Accessories
Voltage Time Range
Delay On Break
See accessory pages for specifications.
+/– 2% under fixed conditions- +/–10%
< 16 ms after timing < 150 ms- +/– 10%
Open during timing Closed during timing 1 A steady state 1 A steady state 10 A inrush at 55°C
≅ 2.5 V at 1 A≥ 2000 V RMS Terminals to mounting surface
≥ 100 MΩ0.25 inch (6.35mm) male quick connect terminals
-40° ... +75°C / -40° ... +85°C
Repeat AccuracyTolerance (Factory Calibration)Recycle TimeTime Delay vs. Temperature & VoltageOutput : - Form
- Rating (max.)- Voltage Drop
Dielectric BreakdownInsulation ResistanceTerminationOperating Temperature / Storage Temperature
V = Voltage L = Load S1 = Initiate Switch TD= Time Delay R = Reset = Undefined Time
Time Diagrams
Versa-knobP/N: P0700 7
External adjust potentiometer P/N: P1004 XXX(See Table above for figure B P/N's.For figure A P/N's, remove 'X' fromfigure B P/N's)
Quick connect toscrew adaptorP/N: P1015 18
DIN railP/Ns:C103PM (Al)17322005 (Steel)
DIN railadaptor
P/N:P1023 20
Plug-on adjustmentmoduleP/N: VTXXX(See Table Above)
Specifications
Female quickconnectP/N: P1015 64(AWG 14/16)(2.45mm2/1.34mm2)
Mounting bracketP/N:P1023 6
Delay On Make Interval Single Shot Delay On Break
P/N P/NP/NP/N
V = Voltage L = Load S1 = Initiate Switch RT= External Adjustment
AFigure B includes Versa-Pot andtwo 8 inch (203mm) wires withfemale quick connect terminals. B
Low Cost Analog Circuitry For General UseTotally Solid State - Encapsulated5 mA ... 1 A Steady - 10 A InrushAdjustable Delays From 50 ms ... 10 mAC Input Voltages+/-2% Repeat Accuracy
www.ssac.com
Other voltages 12 V DC, 24 V AC or DC, 120 V DC,230 V AC and fixed time delay versions are available.
17
RS001E2S 10.14.03
Recycling (ON First)
Recycling (Pulse Generator)RS Digi-SetTiming Module
Digital Circuitry +/-0.1% Repeat AccuracySwitch Setable Time Delays - Both Times Adjustable0.1 s ... 1023 m in 3 RangesInput 120 V AC1 A Steady - 10 A InrushTotally Solid State and Encapsulated
DescriptionThe RS Series is a solid state, encapsulated,recycling timer designed for tough industrialenvironments. It's used by many testing labs asa life cycle tester; by others as a cycle controller.The RS Series has separate 10 switch adjustmentsfor the ON delay and the OFF delay. These makepossible accurate adjustment the first time andevery time. Digital circuitry means accuracy andstability.
OperationUpon application of input voltage, the output isenergized and the ON time begins. At the end ofthe ON time, the output de-energizes and the OFFtime begins. At the end of the OFF time, the outputis energized and the cycle repeats as long as inputvoltage is applied. The OFF time may be the firstdelay in some recycling timers.Reset: Removing input voltage resets the outputand time delays, and returns the sequence to thefirst delay.
Approvals:
Time DelayType Digital integrated circuitryRange* 0.1 ... 102.3 s in 0.1 s increments
0.1 ... 102.3 m in 0.1 m increments1 ... 1023 m in 1 m increments
Repeat Accuracy +/-0.1%Tolerance +/-2%Reset Time 100 msInputVoltage 120 V ACTolerance +/-20%Line Frequency 50 ... 60 HzDC Ripple +/-10%OutputType Solid stateMaximum Load Current 1 A steady state, 10 A inrush at 60°CMinimum Holding Current 5 mAVoltage Drop ≅ 2.5 V AC at 1 A
≅ 1.5 V DC at 1 AProtectionCircuitry EncapsulatedDielectric Breakdown ≥ 2000 V RMS terminals to mounting surfaceInsulation Resistance ≥ 100 MΩMechanicalMounting Surface mount with two to six #8 (M4 x 0.7) screwsPackage 4.5 x 3.1 x 1.3 in. (114 x 79 x 34 mm)Termination 0.25 in. (6.35 mm) male quick connect terminalsEnvironmentalOperating Temperature -40°C ... +80°CStorage Temperature -40°C ... +85°CHumidity 95% relative, non-condensingWeight ≅ 7 oz (198 g)
*For CE approved applications, power must be removed from the unit when a switch position ischanged.
V = Voltage L = Load R = ResetT1 = ON Time T2 = OFF Time
Inches (Millimeters)
Accessories
See accessory pages for specifications.
Female quickconnectP/Ns:P1015 13 (AWG 10/12)P1015 64 (AWG 14/16)P1015 14 (AWG 18/22)
Quickconnect toscrew adaptorP/N: P1015 18
Part NumberInput Voltage ON Time First OFF Time Second
Available in 12, 24 V DC & 24, 120 V ACOther Time Range Combinations are Available
120 V AC120 V AC120 V AC
0.1 ... 102.3 s0.1 ... 102.3 m 1 ... 1023 m
0.1 ... 102.3 s0.1 ... 102.3 m 1 ... 1023 m
RS4A11RS4A22RS4A33
Technical Data
www.ssac.com
Digi-Set Binary Switch Operation
18
Part Numbers
FS001E2S 11.06.03
Input VoltageToleranceFlash RateCustom Flash RatesLoad TypeSurface MountingTerminationOperating TemperatureStorage TemperatureWeightPackage Height Dimension
V = Voltage L = Load R = Reset T1, T2 = Time Delay S1 = Initiate Switch
R = Red Wire B = Black Wire V = Voltage L = Load S1 = Initiate Switch Inches (Millimeters)
Universal Input Voltage 24 ... 240 V ACKnob Adjustable Flash Rate 10...100 FPMOutput Rated 1, 6, 10, or 20 A SteadyTotally Solid State and Encapsulated
12, 24 V DCFixed at 75 Flashes per Minute (FPM)Custom Flash Rate: 60 ... 150 FPM0.25 ... 3 A SteadyTotally Solid State and Encapsulated
www.ssac.com
Connection Diagrams
The FS300 Series were specificallydesigned to operate lamp loads.Their two-terminal series connectionand high immunity to line noise andtransients make the FS300 Seriesideal for moving vehicle operations.Factory fixed flash rate of 75 flashesper minute or may be ordered with afixed custom flash rate ranging from60 to 150 flashes per minute.OperationUpon application of input voltage, theT2 OFF time begins. At the end of theOFF time, the T1 ON time begins andthe load energizes. At the end of T1, T2begins and the load de-energizes.This cycle repeats until input voltage isremoved.Reset: Removing input voltage resetsthe flasher.
Solid State Flashers
Specifications
FS100 Series
FSU1000 Series
FS300 Series
FS100 Series FSU1000 Series FS300 SeriesThe FS100 Series may be used tocontrol inductive, incandescent orresistive loads. This series offers a 1A (fullwave) or a 2 A (halfwave) steadystate, 10 A inrush solid state output;and may be ordered with an inputvoltage of 24 or 120 V AC. Factoryfixed flash rate of 75 flashes perminute or may be ordered with afixed custom flash rate ranging from45 to 150 flashes per minute.OperationUpon application of input voltage, theT2 OFF time begins. At the end of theOFF time, the T1 ON time begins andthe load energizes. At the end of T1, T2begins and the load de-energizes.This cycle repeats until input voltage isremoved.Reset: Removing input voltage resetsthe flasher.
The FSU1000 incorporates anonboard adjustable flash rate of 10to 100 flashes per minute and auniversal input voltage in one device.Its circuitry is capable of controllingloads of up to 20 A steady state.Ideal for applications where variousflash rates and operating voltagesare required.OperationWhen input voltage is applied toterminal 2 and the load (lamp), theload energizes steadily. When inputvoltage is applied to terminal 3, theoutput flashes.Optional Low Current Switch (SW1):This low current switch could be alimit switch or contact. While open,the operator sees the load (lamp)ON and operating. When the limitswitch closes, the load (lamp) flashesto attract attention.
Input Output Load Part Voltage Rating Type Number120 VAC 1A A FS126120 VAC 1A B FS126RC120 VAC 2A A FS12724 VAC 1A A FS14624 VAC 1A B FS146RC*A=Incandescent & Resistive B=Incandescent, Resistive & Inductive Other Voltages and options are available.
Inrush Output Part Rating Rating Number 10 A 1A FSU1000
60 A 6A* FSU1003100 A 10A* FSU1004200 A 20A* FSU1005
Input Load Part Voltage Current Number12 VDC 2.5A FS31224 VDC 1.5A FS324
See accessory pages for specifications.
Accessories
24, 120 V AC, 50 ... 60 Hz+/–15%
Fixed 75 FPM, +/–20%From 45 ... 150 FPM
Incandescent, resistive or inductiveOne #8 (M4 x 0.7) Screw
6 in. (15.2 cm) AWG 20 (.597 mm2) wires-20°C ... +60°C-40°C ... +85°C≅ 1.1 oz (31g)
24 ... 240 V AC, 50 ... 60 HzGuaranteed Range
Adjustable 10 ... 100 FPM
Incandescent, resistive or inductiveOne #10 (M5 x 0.8) Screw
0.25 in. (6.35 mm) male quick connect-20°C ... +60°C (230 V AC +50°C)
-40°C ... +85°C1A: ≅ 2.4 oz (68g), 6A+: ≅ 3.9 oz(111g)
1A units: 1.21 in. (30.7mm)6A, 10A, 20A units: 1.51 in. (38.4mm)
12, 24 V DC12 ... 36 V DC +/–20%
Fixed 75 FPM, +/–10%From 60 ... 150 FPM
Incandescent or resistiveOne #10 (M5 x 0.8) Screw
0.25 in. (6.35 mm) male quick connect-20°C ... +60°C-40°C ... +85°C≅ 2.2 oz (62.3g)
1.21 in. (30.7mm)
Quick connect to screw adaptorP/N: P1015 18
Female quick connect P/N's P1015 13 (AWG 10/12) P1015 64 (AWG 14/16) P1015 14 (AWG 18/22)
Flasher (OFF First) Flasher (OFF First)Flasher (NC)
Low Cost, Small Size24 or 120 V AC are AvailableFixed at 75 Flashes per Minute (FPM)Custom Flash Rate 45 ... 150 FPM1 or 2 Amps Steady - 10 A InrushTotally Solid State and Encapsulated
*Units rated ≥ 6 A must be bolted to a metal surface using the includedheat sink compound. The maximum mounting surface temperature is90°C.
19
TWER1E2S 10.13.03
Flasher · Solid State Beacon Flasher
P/N VOLTAGE DESCRIPTION
SSAC offers a complete line of solid state products to control the lights on communication towers and tall structures. Productsinclude: Beacon flasher modules, auxiliary modules, lamp failure alarm relays, failed flasher alarm relays, plus a photo controlto turn ON and OFF tower lighting at dusk and dawn.
SELECTION GUIDE
Photo Control · Precision Calibrated to FAA and FCC Specifications
Precision Photo Control Calibrated to FAA and FCCSpecifications for Tower and Obstruction Lighting.Two SPST N.O. 20 A Contacts. Without CastAluminum Housing. (not shown)Meets FAA-AC NO: 150/5345-43E
Lamp Alarm Relays · Senses Lamp Failure
Universal Light Alarm Relay. Senses the Failure ofOne Lamp Out of 1, 2, 3, or 4 Lamps; 116 or 620 W,120 V AC Lamps.SPDT - 10 A Isolated Alarm Contacts.Meets FAA-AC NO: 150/5345-43E
Side Light Alarm Relay. Senses the Failure of OneLamp Out of 2, 3, 4, 5, 6, 7, 8, or 9; Steadily Burning116 W, 120 V AC Lamps.SPDT - 10 A Isolated Alarm Contacts. (not shown)
Beacon Alarm Relay · Senses Lamp Failure and Flasher Failure
Flasher and Beacon Lamp Alarm RelaySenses Failure of Beacon LampsSenses Failure of Beacon FlasherTwo Line Voltage Alarm OutputsSPDT - 10 A Isolated Alarm ContactsMeets FAA-AC No: 150/5345-43E
Tower and Obstruction Lighting Controls
As Above with Cast Aluminum Housing. (as shown)
Beacon Flasher for High RF Installations,2500 W (200 A Inrush Maximum)Meets FAA-AC NO: 150/5345-43E
Beacon Flasher for FM, TV, Chimneys, Bridges,Smoke Stacks, and Low RF Applications,2500 W (200 A Inrush Maximum)Meets FAA-AC NO: 150/5345-43E
Auxiliary Unit for Synchronous Flashing ofAdditional Beacons, 2500 W (200 A InrushMaximum)
Auxiliary Unit Provides Alternate Operation forConstant Line Loading, 2500 W (200 A InrushMaximum) (not shown)
FS155 30RF
FS155 30T
FA155 2
FA155
120 V AC
120 V AC
120 V AC
120 V AC
PCR10
PCR11
120 V AC
120 V AC
120 V AC
120 V AC
120 V AC
SCR430T
SCR490D
FB120A
www.ssac.comAlso available for 230 V AC Systems
20
WVM02ELS 10.14.03
www.ssac.comwww.ssac.com
3 Phase Voltage MonitorWVM SeriesMotor Protector
Protects Against: Phase Loss & Reversal; Over, Under& Unbalanced Voltages; Short Cycling10 Fault Memory & Status Displayed on 6 LED ReadoutSwitch Selectable Automatic Restart, DelayedAutomatic Restart, & Manual ResetIsolated 10 A SPDT Relay Contacts
DescriptionThe WVM Series provides protection againstpremature equipment (motor) failure caused byvoltage faults on the 3 Phase Line. The WVM'smicrocontroller design provides reliable protectioneven if regenerated voltages are present. Itcombines dependable fault sensing with a 10 faultmemory and a 6 LED status display. Partinstrument, part control, the WVM protects yourequipment when you're not there and displayswhat happened when you return. The WVM isfully adjustable and includes time delays toprevent nuisance tripping and improve systemoperation. Time delays include a 0.25 to 30 sadjustable trip delay, an adjustable 0.25 to 64 m(in 2 ranges) restart delay, plus a unique 3 to 15 strue random start delay. The random start delayprevents voltage sags caused by simultaneousrestarting of numerous motor loads after a poweroutage.
Approvals:
Line VoltageType 3 phase Delta or Wye with no connection to neutralOperating Voltage Adjustment Range
240 V AC 200 ... 240 V AC480 V AC 400 ... 480 V AC600 V AC 500 ... 600 V AC
Overvoltage, Undervoltage, & Voltage UnbalanceOvervoltage Trip Point 109 ... 113% of adjusted voltage
Reset Voltage -2% of trip pointUndervoltage Trip Point 88 ... 92% of adjusted voltage
Reset Voltage +2% of trip pointVoltage Unbalance Adjustable from 2 ... 10%Trip Delay Adjustable from 0.25 ... 30 s +/-15%Phase Loss ≥ 15% unbalanceResponse Time ≤ 200 msRandom Start Delay Range 3 ... 15 sReset (Restart) DelayLow Range 0.25 ... 64 s +/-15%High Range 0.25 ... 64 m +/-15%Fault MemoryType Nonvolatile RAMCapacity Stores last 10 faultsStatus Indicators 6 LEDs provide existing status & memory readout Note: 50% of operating line voltage must be applied to L1 & L2 for operation of status indicatorsOutputType Electromechanical relayForm Isolated single pole double throw (SPDT)Rating 10 A resistive @ 250 V AC
6 A inductive (0.4 PF) at 250 V ACProtectionSurge IEEE C62.41-1991 Level BIsolation Voltage ≥ 2500 V RMS input to outputMechanicalMounting Surface with 2 or 4 #8 (M4 x 0.7) screwsTermination Screw terminals with captive wire clamps for up to
#12 AWG ( 3.2 mm2) wireEnvironmentalOperating/Storage Temperature -40°C ... +65°C / -40°C ... +85°CWeight ≅ 25 oz ( 709 g)
ASME A17.1 rule 210.6, NEMA MG1 14:30, 14:35,IEEE C62.41-1991 Level B
CAUTION: 2 amp max fast acting fuses mustbe installed externally in series with each input.(3) (Bussman KTK-2 or equivalent)
Voltage Restart Delay Reset Method Part NumberF = Fuses RS = Optional Remote Reset SwitchNO = Normally Open NC = Normally Closed
F = 2 AMPFAST ACTING
FUSES
ANSI Device #27/47/59
Technical Data
200 ... 240 V200 ... 240 V400 ... 480 V400 ... 480 V500 ... 600 V500 ... 600 V200 ... 240 V400 ... 480 V500 ... 600 V
0.25 ... 64 s0.25 ... 64 m0.25 ... 64 s0.25 ... 64 m0.25 ... 64 s0.25 ... 64 m
NoneNoneNone
WVM611AL WVM611AH WVM911AL WVM911AH WVM011AL WVM011AH WVM611M WVM911M WVM011M
Switch SelectableSwitch SelectableSwitch SelectableSwitch SelectableSwitch SelectableSwitch Selectable Manual Reset Manual Reset Manual Reset
Relay contacts are isolated. Dashed lines areinternal connections.
Other Options, Voltages, and Time Delays are Available
2 1.83 2.74 3.65 4.56 5.47 6.38 7.29 8.1
10 9
Reset on Balance
Selected Unbalance % Reset %
Inches (Millimeters)
21
WVM02ERS 08.18.03
Clear Tamperproof CoverThe P0500-153 protects against unauthorizedadjustment of the trip points. It prevents theresetting of manual units by the equipment'soperator. It isolates line-level connection pointspreventing contact during troubleshootingoperations. Alignment dimples allow drilling (5places) for limited access to adjustment knobsand the reset switch. Included are (2) spacers,(5) hole plugs. 7.5 x 4.7 x 2.6 in. (190.5 x 119.4x 66 mm)
35mm DIN Rail AdaptorThe P1011-38 provides an easy method ofmounting the WVM Series on 35mm DIN rail.Constructed of rugged black anodized steel, theP1011-38 adaptor includes four mountingscrews. 7 x 4.5 x .33 in. (177.8 x 114.3 x 8.4mm)
OperationThe output relay is energized when all conditionsare acceptable and the WVM is reset. A restartand/or random start delay may occur before theoutput relay is energized.
Field Adjustment: Select the line voltage listedon the motor's name plate. This automaticallysets the over and undervoltage trip points. Consultthe equipment's manufacturer specifications forthe correct trip delay, unbalance percentage, andrestart/reset operation and restart delay. Makeconnection to all three line phases as shown inthe connection diagram. Apply power. If the relayfails to energize, view the LEDs for the cause, andcorrect the problem. If the phase sequence isincorrect, swap any two wires. No furtheradjustment should be required to achievemaximum equipment protection.
Read Memory: Fault(s) stored in the memoryare indicated when the yellow LED is flashing. Toread memory, rotate selector from Manual to ReadMemory. The last fault will be displayed. Repeatthis operation to read the second to the last fault.Repeat until up to 10 faults are noted.
Memory Reset: To clear the memory of allfaults stored, rotate selector to Clear Memory
for 5 seconds. The yellow LED will turn off.Memory Overload: The 11th fault causes thefirst to be removed from memory. Only the 10most recent faults are retained.
Random Start Delay: A new 3 to 15 s randomstart delay is selected by the microcontroller whena fault is corrected and when the operating voltage(L1, L2, L3) is applied to the WVM. A randomstart delay does not occur when the reset ismanual.
Automatic Restart: Upon fault correction, theoutput will re-energize after a random start delay.
Automatic Restart Upon Fault Trip: When afault is sensed for the full trip delay, the output de-
Accessories
3 Phase Voltage MonitorWVM SeriesMotor Protector
energizes and a restart delay is initiated. Thisdelay locks out the output for the delay period.Should the fault be corrected by the end of therestart delay, the output will re-energize after arandom start delay. A restart delay will also occurwhen operating voltage (L1, L2, L3) is applied tothe WVM.
Manual Reset: After a fault condition iscorrected, the WVM can be manually reset. Thereare two methods; a switch on the unit or acustomer supplied remote switch.
Manual Reset Units: (P/N ends with M) Thesepart numbers have a 3 position selector switch.An on board momentary reset switch is providedon the unit for manual reset.
Switch Selected Reset Units: (P/N includesan A or R) These part numbers have a 5 positionselector switch. Rotate selector switch from theManual Reset position to Auto Restart w/Delaythen back again to Manual Reset within 3seconds. The output will immediately energize.
Remote Reset: Reset (Restart) is accomplishedby a momentary contact closure across terminals1 & 2. The output will immediately energize.Remote switch requirements are ≥ 10 mA at20 V DC and the reset terminals are not isolatedfrom line voltage. A resistance of ≤ 20KΩ acrossterminals 1 & 2 will cause immediate automaticrestart.
Automatic Restart Upon Fault Correction:(Optional operation, call for P/Ns.)When a fault is sensed for the full trip delay, theoutput relay de-energizes. Upon correction ofthe fault, a restart delay begins. At the end ofthis delay, the output will re-energize after arandom start delay. If a fault occurs during timing,the time delay will be reset to zero, and the outputwill not energize until the restart delay is completed.
P/N: P1011 38
P/N: P0500 153
Inches (Millimeters)
Three phase fuse blockdisconnect designed for usewith HRC midget fuses [1.5 x0.41 in.] (38.1 x 10.3 mm)rated up to 25 A at 500 V AC.Surface or 35mm DIN railmountable. 3.9 x 2.09 x 2.2in. (99 x 53.1 x 55.9 mm)P/N: P0700 241
2.1 in.
Midget FuseFast acting fuse for use withvoltage monitors. Rated 2 A at500 V AC.1.5 x 0.41 in. (38.1 x 10.3 mm)P/N: P0600 11
DIN railP/N: C103PM (Al)17322005 (Steel)
1.5 in.
www.ssac.com
22
PLMU1E2S 01.13.04
www.ssac.com
F = Fuses = Phase A = L1 = Phase B = L2 = Phase C = L3NO = Normally OpenNC = Normally Closed
Line VoltageType Three phase Delta or Wye with
no connection to neutralLine Voltage 200 ... 480 V AC +/-15%; 50 ... 60 Hz +/-2 HzAdjustable Voltage Ranges (Automatic Range Selection) 200 ... 240 V AC, 50 ... 60 Hz
340 ... 420 V AC, 50 Hz400 ... 480 V AC, 60 Hz
Maximum voltage 552 V ACPhase Sequence ABCOvervoltage, Undervoltage, & Voltage UnbalanceType Voltage detection with delayed trip & automatic resetOvervoltage & Undervoltage
Undervoltage Trip Point 88 ... 92% of adjusted line voltageReset Voltage +2% of trip voltageOvervoltage Trip Point 109 ... 113% of adjusted line voltageReset Voltage -2% of trip voltage
Voltage Unbalance Trip Point Adjustable from 2 ... 10% or fixed 4 ... 10%
Reset on Balance (%): Selected Unbalance 2 3 4 5 6 7 8 9 10 Reset 1.5 2.5 3.5 4.5 5.4 6.3 7.2 8.1 9Trip Delay Range Adj. from 0.25 ... 30 s or fixed 2 ... 30 s +/-15%Severe Unbalance - 2X Selected Unbalance 0.25 ... 2 s; if trip delay is less than 2 s;
the trip delay is usedRandom Start Delay ≅ 0.6 sPhase Reversal & Phase Loss Trip Time ≤ 150 msPhase Loss Set Point ≥ 15% unbalanceReset Type AutomaticOutput Type Energized when voltages are acceptableRating 10 A resistive @ 240 V AC; 1/4 hp @ 125 V AC;
1/3 hp @ 250 V AC; max. voltage 277 V ACLife Mechanical -- 1 x 106 ; Electrical -- 1 x 105
ProtectionSurge IEEE C62.41-1991 Level BIsolation Voltage ≥ 2500 V RMS input to outputMechanicalMounting* Plug-in socket rated 600 V ACTermination 8-Pin Octal plugPackage 3.03 x 2.39 x 1.78 in. (77.0 x 60.7 x 45.2 mm)EnvironmentalOperating Temperature -40°C ... +60°CStorage Temperature -40°C ... +85°CWeight ≅ 8.6 oz (244 g)
Protects Against: Phase Loss, Phase Reversal,Overvoltage, Undervoltage, & Unbalanced VoltagesOctal Plug-in with SPDT Isolated 10 A ContactsOperates from 200 ... 480 V ACLED Indicator Glows Green when Voltages are Acceptable,Red for FaultsSimple 3-Wire Connection for Delta or Wye Systems
DescriptionThe PLMU Series continuously measures the voltage of each of the three phases to provide protectionfor three phase motors and sensitive loads. Its microcontroller senses under and over voltage,voltage unbalance, phase loss, and phase reversal. Protection is provided even when regeneratedvoltages are present. Universal voltage operation and standard base connection allows the PLMU toreplace hundreds of competitive part numbers.
3 Phase Voltage MonitorPLMU SeriesUniversal Plug-in Monitor
Part NumberVoltage Unbalance
ASME A17.1 rule 210.6; NEMA MG1 14:30, 14:35;IEEE C62.41-1991 Level B
Trip Delay
Available with Fixed Unbalance and Trip Delay
OperationUpon application of power, a 0.6 s random startdelay begins and the PLMU measures thevoltage levels and line frequency and selectsthe voltage range. The output relay is energizedand the LED glows green when all voltages areacceptable and the phase sequence is correct.LED flashes green during trip delay, glows redwhen output de-energizes. Undervoltage,overvoltage, and voltage unbalance must besensed for continuous trip delay before the relayde-energizes. Re-energization is automatic uponfault correction. The output relay will not energizeif a fault condition is sensed as three phase inputvoltage is applied. Line voltage is selected withthe knob, setting the over and undervoltage trippoints. Voltage range is automatically selectedby the microcontroller.
Approvals:
*CAUTION: Select an octal socket rated for 600 V AC operation.
Inches (Millimeters)
Faceplate View
2 AmpFast Acting
FusesRecommended
Relay contacts are isolated. Dashed lines areinternal connections.
CAUTION: 2 amp max fast acting fuses shouldbe installed externally in series with each input.(3) (Bussman KTK-2 or equivalent)
ANSI Device #27/47/59
See accessory pages for specifications.
Accessories
Octal8-pin socketP/N: OT08PC
Panel mount kitP/N: BZ1
DIN railP/Ns: C103PM (Al) 17322005 (Steel)
Adjustable 2 ... 10% PLMU11Adjustable 0.25 ... 30 s
Technical Data
OAOBOC
Midget FuseFast acting fuse for use with voltagemonitors. Rated 2 A at 500 V AC.1.5 x 0.41 in. (38.1 x 10.3 mm)P/N: P0600 11
1.5 in.
Three phase fuse block disconnectdesigned for use with HRC midgetfuses [1.5 x 0.41 in.] (38.1 x 10.3mm) rated up to 25 A at 500 V AC.Surface or 35mm DIN railmountable. 3.9 x 2.09 x 2.2 in.(99 x 53.1 x 55.9 mm)P/N: P0700 241
2.1 in.
23
DLM01E2S 11.06.03
Line Voltage
3 Phase Voltage MonitorDLM SeriesMotor Protector
Protects Against: Phase Loss, Phase Reversal, Overvoltage, Undervoltage, and Voltage Unbalance
35 mm DIN Rail or Surface MountingSPDT Isolated 10 A Relay ContactsLED Glows when All Conditions are AcceptableLine Voltage 200 ... 600 V AC, in 3 RangesSimple 3 Wire Connection for Delta or Wye Systems
DescriptionThe DLM Series continuously measures thevoltage of each of the three phases. It separatelysenses under and over voltage, voltage unbalanceincluding phase loss and phase reversal.Protection is assured during periods of largeaverage voltage fluctuations, or when regeneratedvoltages are present. Both Delta and Wyesystems can be monitored; no connection toneutral required.
OperationThe output relay is energized and the LED glowswhen all voltages are acceptable and the phasesequence is correct. Undervoltage, overvoltage,and voltage unbalance must be sensed forcontinuous trip delay period before the relay andthe LED are de-energized. Re-energization isautomatic upon correction of the fault condition.The output relay will not energize if a fault conditionis sensed as power is applied.
Approvals:
Type 3 phase Delta or Wye with no connection to neutralOperating Voltage Line Voltage Range Line Voltage Max. Calibration Frequency
240 200 ... 240 V AC 270 V AC 60 Hz480 400 ... 480 V AC 530 V AC 60 Hz600 500 ... 600 V AC 600 V AC 60 Hz
Line Frequency 50 ... 60 HzPhase Sequence ABCOvervoltage, Undervoltage, & Voltage UnbalanceType Voltage detection with delayed trip & automatic resetOvervoltage & Undervoltage:
Undervoltage Trip Point 88 ... 92% of adjusted line voltageReset Voltage +3% of trip voltageOvervoltage Trip Point 109 ... 113% of adjusted line voltageReset Voltage -3% of trip voltage
Voltage Unbalance:Trip Unbalance Adjustable from 2 ... 8%
Trip Delay: Range Adjustable from 2 ... 20 sTolerance Adjustable-guaranteed range
Phase ReversalResponse Time -- Phase Reversal ≤100 msReset AutomaticOutputType Electromechanical relayForm Single pole double throw (SPDT)Rating 10 A resistive @ 240 V AC; 1/4 hp @ 125 V AC;
1/3 hp @ 250 V AC; max. voltage 277 V ACLife Mechanical -- 1 x 106 ; Electrical -- 1 x 105
Protection Surge IEEE C62.41-1991 Level BIsolation Voltage ≥ 2500 V RMS input to outputCircuitry EncapsulatedMechanicalMounting Surface with 2 #8 (M4 x 0.7) screws or 35 mm DIN railPackage 4.33 x 2.95 x 1.97 in. (110 x 75 x 50 mm)Termination Screw terminals with captive wire clamps for up
to #14 AWG (2.5 mm2) wire Touch proof terminal covers are included
EnvironmentalOperating/Storage Temperature -40°C ... +60°C / -40°C ... +85°CHumidity 95% relative, non-condensingWeight 120 & 240 V AC ≅ 8.6 oz (244 g)
480 ... 600 V AC ≅ 16.3 oz (462 g)
ASME A17.1 rule 210.6, NEMA MG1 14:30, 14:35,IEEE C62.41-1991 Level B
Field Adjustment: Set voltage, delay period,and voltage unbalance percentage (consultequipment manufacturer's specifications). Makeconnection to all three line phases as shown inthe connection diagram. Apply power. If the relayfails to energize, check the wiring of all 3 phases,voltage, and phase sequence. If phase sequenceis incorrect, swap any two wires. No furtheradjustment should be required to achievemaximum equipment protection.
CAUTION: 2 amp max fast acting fuses mustbe installed externally in series with each input.(3) (Bussman KTK-2 or equivalent)
Line Voltage Voltage Unbalance Trip Delay Part Number
F = FusesNO = Normally OpenNC = Normally Closed
2 AMPFAST ACTING
FUSES
Accessories
See accessory pages for specifications.
DIN railP/Ns: C103PM (Al) 17322005 (Steel)
Inches (Millimeters)
RC = Removable Terminal Cover
ANSI Device #27/47/59
240 V AC480 V AC600 V AC
2 ... 8%2 ... 8%2 ... 8%
2 ... 20 s2 ... 20 s2 ... 20 s
DLM611DLM911DLM011
Technical Data
2 1.83 2.74 3.65 4.56 5.47 6.38 7.2
Note: A 60 Hz unit used on 50 Hz willshift by -1. A 50 Hz unit used on 60 Hzwill shift by +1. (Ex. 4% unbalance on 60Hz, would be 3% unbalance on 50 Hz.)
Reset on Balance
Selected Unbalance Reset %
Midget FuseFast acting fuse for use with voltagemonitors. Rated 2 A at 500 V AC.1.5 x 0.41 in. (38.1 x 10.3 mm)P/N: P0600 11
1.5 in.
Three phase fuse block disconnectdesigned for use with HRC midgetfuses [1.5 x 0.41 in.] (38.1 x 10.3mm) rated up to 25 A at 500 V AC.Surface or 35mm DIN railmountable. 3.9 x 2.09 x 2.2 in.(99 x 53.1 x 55.9 mm)P/N: P0700 241 2.1 in.
www.ssac.com
Also Available for 380 V AC
24
RLM01E2S 10.14.03
3 Phase Voltage MonitorRLM SeriesMotor Protector
Protects Against: Phase Loss, Phase Reversal,Undervoltage, & Unbalance VoltagesIndustrial Packaging with Encapsulated CircuitryFully Adjustable or Factory FixedSPDT Isolated 8 A ContactsLED Glows When All Conditions are AcceptableLine Voltages 200 ... 480 V AC, in 2 Ranges
DescriptionThe RLM Series of encapsulated three phasevoltage monitors continuously measures thevoltage of each of the three phases. Its circuitdesign separately senses Phase Reversal,Undervoltage, and Voltage Unbalance includingPhase Loss. Protection is assured during periodsof large average voltage fluctuations, or whenregenerated voltages are present. Both Delta andWye systems can be monitored; no connection toneutral is required.
OperationThe output relay is energized and the LED glowswhen all voltages are acceptable and the phasesequence is correct. Undervoltage and voltageunbalance must be sensed for a continuous tripdelay period before the relay and the LED are de-energized. Re-energization is automatic uponcorrection of the fault condition. The output relaywill not energize if a fault condition is sensed aspower is applied.
Approvals:
Line VoltageType 3 phase Delta or Wye with no connection to neutralOperating Voltage:UL CSA Model Adj. Line Voltage Range Line Voltage Max. Calibration Frequency • • 240 200 ... 240 V AC 270 V AC 60 Hz • • 480 400 ... 480 V AC 530 V AC 60 Hz
Line Frequency 50 ... 60 HzPhase Sequence ABCUndervoltage and Voltage UnbalanceType Voltage detection with delayed trip
& automatic resetUndervoltage: Trip Voltage 88 ... 92% of adjusted line voltage
Reset Voltage +3% of trip voltageVoltage Unbalance: Trip Unbalance 240 & 480 V AC Adj. 2 ... 6%;
or fixed at 4, 5, 6, 7, or 8% Reset on Balance (%): Selected Unbalance 2 3 4 5 6 7 8
Reset 1.8 2.7 3.6 4.5 5.4 6.3 7.2Note: A 60 Hz unit used on 50 Hz will shift by -1. A 50 Hz unit used on 60 Hz will shift by +1.(Ex: 4% unbalance on 60 Hz would be 3% unbalance on 50 Hz.)Trip Delay: Range Adjustable or Factory fixed from 2 ... 20 s
Tolerance Adjustable: Guaranteed range; Factory fixed: +/-15%Phase ReversalResponse Time -- Phase Reversal ≤100 msReset AutomaticOutputType Electromechanical relayForm Single pole double throw (SPDT)Rating 8 A resistive at 240 V AC; max. voltage 277 V ACProtectionSurge IEEE C62.41-1991 Level BIsolation Voltage ≥ 2500 V RMS input to outputCircuitry EncapsulatedMechanicalMounting Surface mount with two #8 (M4 x 0.7) screwsTermination 0.25 in. (6.35 mm) male quick connect terminalsEnvironmentalOperating Temperature -40°C ... +60°CStorage Temperature -40°C ... +85°CHumidity 95% relative, non-condensingWeight ≅ 8.7 oz (247 g)
ASME A17.1 rule 210.6, NEMA MG1 14:30, 14:35,IEEE C62.41-1991 Level B
Field Adjustment: Set voltage, delay period, andvoltage unbalance percentage (consult equipmentmanufacturer's specifications). Make connectionto all three line phases as shown in the connectiondiagram. Apply power. If the relay fails to energize,check the wiring of all 3 phases, voltage, andphase sequence. If phase sequence is incorrect,swap any two wires. No further adjustment shouldbe required to achieve maximum equipmentprotection.
CAUTION: 2 amp max. fast acting fuse mustbe installed externally in series with each input.(3) (Bussman KTK-2 or equivalent)
2 AmpFast Acting
Fuses
Inches(Millimeters)
See accessory pages for specifications.
Accessories
Female quick connectP/Ns:P1015 13 (AWG 10/12)P1015 64 (AWG 14/16)P1015 14 (AWG 18/22)
ANSI Device #47/27
Trip DelayVoltage UnbalanceLine Voltage Part Number
Fixed Unbalance and Trip Delays 380 V AC, are Available
F = Fuses = Phase A = L1 = Phase B = L2 = Phase C = L3
OAOBOC∆U∆V∆T
= Unbalance Adjustment= Line Voltage Adjustment= Trip Delay Adjustment
200 ... 240 V AC400 ... 480 V AC
2 ... 6%2 ... 6%
2 ... 20 s2 ... 20 s
RLM611RLM911
Technical Data
Midget FuseFast acting fuse for use with voltagemonitors. Rated 2 A at 500 V AC.1.5 x 0.41 in. (38.1 x 10.3 mm)P/N: P0600 11
1.5 in.
Three phase fuse block disconnectdesigned for use with HRC midgetfuses [1.5 x 0.41 in.] (38.1 x 10.3mm) rated up to 25 A at 500 V AC.Surface or 35mm DIN railmountable. 3.9 x 2.09 x 2.2 in.(99 x 53.1 x 55.9 mm)P/N: P0700 241
2.1 in.
www.ssac.com
25
ECS01E2S 10.14.03
24 V AC 24 V AC120 V AC120 V AC
0.5 ... 5 A 2 ... 20 A0.5 ... 5 A 2 ... 20 A
0.5 ... 50 s0.5 ... 50 s0.5 ... 50 s0.5 ... 50 s
1 s1 s1 s1 s
ECS20BCECS21BCECS40BCECS41BC
Accessories
See accessory pages for specifications.
Female quick connect P/Ns: P1015 13 (AWG 10/12) P1015 64 (AWG 14/16) P1015 14 (AWG 18/22)
Over/Under Current SensingECS SeriesCurrent Sensor
Toroidal Through Hole Wiring0.5...20 A Trip PointAdjustable or Factory Fixed Trip Delays10 A SPDT Isolated Output Contacts5% Trip Point Hysteresis (Dead Band)
DescriptionThe ECS Series of Single Phase AC Current Sensorsis a universal, overcurrent or undercurrent sensingcontrol. Its built-in toroidal sensor eliminates theinconvenience of installing a stand-alone currenttransformer. Includes onboard adjustments forcurrent sensing mode, trip point, and trip delay.Detects over or undercurrent events like locked rotor,loss of load, an open heater or lamp load, or provesan operation is taking place or has ended.AdjustmentSelect the desired function, over or under currentsensing. Set the trip point and trip delay toapproximate settings. Apply power to the ECS andthe monitored load. Turn adjustment and watch theLED. LED will light; turn slightly in opposite directionuntil LED is off. Adjustment can be done whileconnected to the control circuitry if the trip delay isset at maximum.OperationWhen a fault is sensed throughout the trip delay, theoutput relay is energized. When the current returnsto the normal run condition, the output and the delayare reset. If a fault is sensed and then correctedbefore the trip delay is completed, the relay will notenergize and the trip delay is reset to zero.
Approvals:
SensorType Toroidal, through hole wiringMode Over or undercurrent, switch selectable
on the unit or factory fixedTrip Point Range 0.5 ... 20 A in 2 adjustable ranges or fixedTolerance: Adjustable Guaranteed range Fixed 0.5 ... 25 A: 0.5 A or +/-5% whichever is lessMaximum Allowable Current Steady – 50 A turns; Inrush – 300 A turns for 10 sTrip Point Hysteresis ≅ +/-5%Trip Point vs. Temperature +/-5%Response Time ≤ 75 msFrequency 45 ... 500 HzType of Detection Peak detectionTrip DelayType AnalogRange: Adjustable 0.150 ... 7 s; 0.5 ... 50 s (Guaranteed ranges)
Factory Fixed 0.08 ... 50 s (+/-10%)Delay vs. Temperature +/-15%Sensing Delay on Startup Factory fixed 0 ... 6 s +40% ... 0%InputVoltage 24 , 120, or 230 V AC; 12 or 24 V DCTolerance 12 V DC & 24 V DC/AC -15% ... +20%
120 & 230 V AC -20% ... +10%Line Frequency 50 ... 60 HzOutputType Electromechanical relayForm Isolated single pole double throw (SPDT)Rating 10 A resistive at 240 V AC; 1/4 hp at 125 V AC;
1/2 hp at 250 V ACLife Mechanical – 1 x 106 ; Electrical – 1 x 105
ProtectionCircuitry EncapsulatedIsolation Voltage ≥ 2500 V RMS input to outputInsulation Resistance ≥ 100 MΩMechanicalMounting Surface mount with two #6 (M3.5 x 0.6) screwsTermination 0.25 in. (6.35 mm) male quick connect terminals (5)Humidity 95% relative, non-condensingOperating/Storage Temperature -40°C ... +60°C / -40°C ... +85°CWeight ≅ 6.4 oz (181 g)
Multiple Turns To Increase SensitivityTo increase sensitivity, multiple turns may be madethrough the ECS's toroidal sensor. The trip pointrange is divided by the number of turns through thetoroidal sensor to create a new range.
Using an External Current Transformer (CT)Select a 2 VA, 0 to 5 A output CT, rated for thecurrent to be monitored. Select ECS adjustmentrange 0. Pass the CT's secondary wire leadthrough the ECS's toroid.
V = Voltage W = Insulated Wire CarryingMonitored Current I> = OvercurrentI< = Undercurrent TP = Trip Point R = ResetOC = Monitored Current NO = Normally OpenContact NC = Normally Closed ContactA = Sensing Delay On Start Up TD = Trip Delay
Inches (Millimeters)
Overcurrent
Undercurrent
Relay contacts are isolated.Dashed line are internal connections.
Input Voltage Trip Point Adjustable Trip Delay Adjustable Start Up Delay Part Number
Other Combinations and Delays are Available Including Fixed Set Points, 24 V AC, 230 V AC
Technical Data
www.ssac.com
26
TCS01E2S 03.27.02
www.ssac.com
SensorType Toroid, through hole wiring, alternating currentCurrent to Actuate Adjustable Units -- 2 ... 20 A, Guaranteed range
Fixed Units -- 2 ... 45 A, +0/-20%Reset Current ≅ 95% of the actuate currentMaximum Allowable Current Steady -- 50 A-turns
Inrush -- 300 A-turns for 10 sActuate Current vs. Temperature & Voltage ≤ +/-5%Response Times Overcurrent -- ≤ 200 ms
Undercurrent -- ≤ 1 sBurden < 0.5 VAOutputType Solid stateForm Normally Open or Normally ClosedRating 1 A steady, 10 A inrushOn State Resistance or Voltage Drop DC N.O. & N.C. -- ≅ 1.2 V
AC N.O. & N.C. -- ≅ 2.5 VVoltage AC -- 24 ... 240 V AC +10/-20%
DC -- 3 ... 50 V DCProtectionCircuitry EncapsulatedDielectric Breakdown ≥ 2000 V RMS terminals to mounting surfaceInsulation Resistance ≥ 100 MΩMechanicalMounting Surface mount with one #10 (M5 x 0.8) screwPackage 2 x 2 x 1.75 in. (50.8 x 50.8 x 44.5 mm)Termination 0.25 in. (6.35 mm) male quick connect terminals (2)EnvironmentalOperating/Storage Temperature -20°C ... +60°C / -40°C ... +85°CHumidity 95% relative, non-condensingWeight ≅ 2.6 oz (74 g)
Direct Connection to PLC Input3 ... 50 V DC, 24 ... 240 V AC in 2 Ranges1 A Steady - 10 A Inrush Solid State OutputActuation Points – 2 ... 45 A (Fixed Units)
2 ... 20 A (Adjustable Units)Normally Open or Closed Solid State OutputComplete Isolation Between Sensed Current &Control Circuit
DescriptionThe TCS Series is a low cost method of GO/NOGO current detection. It includes a solid stateoutput to sink or source current when connecteddirectly to a standard PLC digital input module.Its normally open or normally closed output canalso be used to control relays, lamps, valves, andsmall heaters rated up to 1 A steady, 10 A inrush.The TCS is self-powered (no external powerrequired to operate the unit) available with anadjustable actuation range of 2 to 20 A or factoryfixed actuation points from 2 to 45 A.
OperationNormally Open: When a current equal to orgreater than the actuate current is passed throughthe toroidal sensor, the output closes. When thecurrent is reduced to 95% of the actuate currentor less, the output opens.Normally Closed: When the current through thetoroid is equal to or greater than the actuatecurrent, the output opens. When the current isreduced below 95% of the actuate current, theoutput closes.
AC Current Sensor PLCInterfaceTCS SeriesCurrent Sensor
Approvals:
Positive Switching
NegativeSwitching
L = Load V = Voltage PS = Power SupplyPLC = PLC Digital Input Module R = ResetTP = Trip Point OC = Monitored CurrentNO = Normally Open Output NC = NormallyClosed Output
Accessories
See accessory pages for specifications.
DIN rail P/Ns:17322005 (Steel)
DIN rail adaptorP/N: P1023 20
→←
Femalequickconnect
P/N:P1015 64 (AWG 14/16)
MountingbracketP/N: P1023 6
Quickconnect toscrew adaptorP/N: P1015 18
C103PM (Al)
GO/NO GO Sensing
Inches(Millimeters)
Sinking
Sourcing
Monitored ACConductor must beinsulated.
Part NumberInput Voltage Output FormActuation Point Adj.
Fixed Actuation Points to 45 A are Available
3 ... 50 V DC 3 ... 50 V DC24 ... 240 V AC24 ... 240 V AC
2 ... 20 A 2 ... 20 A 2 ... 20 A 2 ... 20 A
Normally OpenNormally ClosedNormally OpenNormally Closed
TCSGAATCSGABTCSHAATCSHAB
Technical Data
Multiple Turns To Increase SensitivityTo increase sensitivity, multiple turns may be madethrough the TCS's toroidal sensor. The trip pointrange is divided by the number of turns through thetoroidal sensor to create a new range.Using an External Current Transformer (CT)Select a 2 VA, 0 to 5 A output CT, rated for the currentto be monitored. Select TCS adjustment range 0.Pass the CT's secondary wire lead through theTCS's toroid.
27
TCSA1E2S 05.20.03
PS
4 10 20
A
50, 20, 10, 5
25, 10, 5, 2.5
0
www.ssac.com
SensorType Toroid, through hole wiring, alternating current
Monitored conductor must be properly insulatedMonitored AC Current 0 ... 50 ARanges
4 factory calibrated ranges 0 ... 5A, 0 ... 10A, 0 ... 20A, or 0 ... 50AFactory Calibration +/-0.5% of full scale
Maximum Allowable Current Steady – 50 A turnsInrush – 300 A turns for 10 s
Repeat Accuracy +/-0.25% of full scale under fixed conditionsResponse Time ≅ 300 msBurden ≤ 0.5 VAFrequency 0 ... 20A / 21 ... 50A 20 ... 100 Hz / 30 ... 100 HzTemperature Coefficient +/-0.05%/°COutputType: Series Connection Current directly proportional to monitored currentRange 4 ... 20 mASensor Supply Voltage* 10 ... 30 V DCMomentary Voltage 40 V DC for 1 mZero Adjust ≅ 3.75 ... 4.25 mASpan Adjust 18 mA ... 22 mAAdjustment Mini-screw, 25 turn potentiometerProtectionDielectric Breakdown ≥ 2000 V RMS terminals to mounting surfaceInsulation Resistance ≥ 100 MΩPolarity Units are reverse polarity protectedMechanicalMounting Surface mount with one #10 (M5 x 0.8) screwPackage 2 x 2 x 1.75 in. (50.8 x 50.8 x 44.5 mm)Termination 0.25 in. (6.35 mm) male quick connect terminalsSensor Hole 0.36 in. (9.14 mm) for up to #4 AWG
(21.1 mm2) THHN wireEnvironmentalOperating Temperature -30°C ... +60°CStorage Temperature -40°C ... +85°CHumidity 95% relative, non-condensingWeight ≅ 2.4 oz (68 g)
Monitors 0 ... 50 A in 4 RangesLoop Powered from 10 ... 30 V DCLinear Output from 4 ... 20 mAZero and Span AdjustmentsComplete Isolation Between Sensed Current andControl Circuit
DescriptionThe TCSA Series is a loop powered, linear outputcurrent transducer that provides an output that isdirectly proportional to the RMS AC currentpassing through the onboard toroid. The TCSAprovides a 4 to 20 mA output over a power supplyrange of 10 to 30 V DC. Each unit is factorycalibrated for monitoring from 0 to 5, 0 to 10,0 to 20, or 0 to 50 A in four ranges. The 0 to 5 Arange allows the use of external currenttransformers so loads up to 1200 AC amps canbe monitored.
OperationThe TCSA varies the effective resistance of itsoutput in direct proportion to the current flowingin the monitored conductor. The unit is factorycalibrated so that 0 amps provides a 4 mA outputand full span provides a 20 mA output. Zero andspan adjustments are provided for minorcalibration adjustments in the field (if required).
AC Current TransducerTCSA SeriesLoop Powered
Approvals:
Part NumberCurrent Range
Accessories
See accessory pages for specifications.
DIN rail P/Ns:17322005 (Steel)
DIN rail adaptorP/N: P1023 20
→←
Femalequickconnect
P/N: P1015 64 (AWG 14/16)
Quickconnect toscrew adaptorP/N: P1015 18
C103PM (Al)
Inches (Millimeters)
PS = Power SupplyW = Insulated Wire Carrying Monitored CurrentPLC = PLC Analog Input or Meter InputS = Span Adjust Z = Zero Adjust
Output mA
MonitoredCurrentAmps
*Minimum loop power supply voltage equals the minimum sensor voltage 10 V DC plus the voltagedrop developed across all the other loop devices at 20 mA.
0 ... 5 A0 ... 10 A0 ... 20 A0 ... 50 A
TCSA5TCSA10TCSA20TCSA50
Technical Data
MountingbracketP/N: P1023 6
28
LCS01E2S 03.27.02
www.ssac.com
0.46(11.68)
0.36 DIA (9.14)
1.51(38.35)
0.98(24.89)
12(304.8)
#24 AWG
UL1015(0.25 mm2)
CURRENT RESISTOR
12 ± 1(304.8 ± 25.4)
STRIPPED 0.25 (6.35)0.53
(13.46)
0.28(7.11)
0.22(5.59)
0.03(0.76)
UL100724 AWG (0.25 mm2 ) <_
AC Current IndicatorLCS10T12 & LPMGo-Glow Indicator
Low Cost Go/No Go IndicationMay Be Connected To Wires Up To 500 Feet (152.4 m)LongRemote Current Monitoring of Currents Up To 50 AGreen or Red LED Indicator Available
DescriptionThe LCS10T12 connected to the LPM12 orLPMG12 indicator is a low cost, easy to use, go/no go indication system for the remote monitoringof current flow. The LCS10T12 is installed on anadequately insulated wire of the monitored load.Its 12 in. (30.4 cm) leads are connected to theLPM12 or LPMG12 panel mount indicator directlyor via customer supplied wires up to 500 feet(152.4 m) long.
OperationWhen the monitored current is 5 ampere-turns,the panel mount LPM indicator will glow. TheLCS10T12 is designed to maximize the light outputof the panel mount indicator. It can be used tomonitor current flow of less than 5 A by passingthe monitored conductor 2 or more times throughthe sensor.
Part Number
SpecificationsCurrent Range 2 ... 50 A AC
Wire Passes Min. Current Max. Current Max. Inrush Max. Wire Dia.1 5 A 50 A 120 A 0.355 in. (9.0 mm)2 2.5 A 25 A 60 A 0.187 in. (4.7 mm)3 1.7 A 16.6 A 40 A 0.15 in. (3.8 mm)4 1.3 A 12.5 A 30 A 0.125 in. (3.2 mm)5 5/X 50/X 120/X
Maximum Current 50 ampere-turns continuousFrequency 50 ... 60 HzDC Resistance 65 ΩSensor Hole 0.36 in. (9.14 mm) for up to #4 AWG
(21.1 mm2) THHN wireTermination 12 in. (30.4 cm) wire leadsOperating Temperature -40°C ... +60°CWeight LCS: ≅ 0.8 oz (23 g)
LPM: ≅ 0.2 oz (6 g)
DescriptionAC Current SensorRed LED IndicatorGreen LED Indicator
Wire Length:500 Ft. (152.4 m) Max.(Customer Supplied)
Approvals:
The LCS10T12 AC current sensor is installed ona wire of the monitored load. Its wire leadsconnect to the LPM12 or LPMG12 panel mountindicator.
Inches (Millimeters)
Panel mount indicator designed to match theoutput of SSAC's LCS10T12. The LPM12 andLPMG12 come with 12 in. (30.4 cm) wires and aone piece mounting clip. Both devices installquickly in a 0.25 in. (6.35 mm) hole in panels from0.031 ... 0.062 in. (0.79 ... 1.6 mm) thick.
Inches (Millimeters)
Technical Data
LCS10T12LPM12LPMG12
CAUTION: The LCS10T12 must be connectedto the LPM12 or LPMG12 before current flowsto prevent damage or a shock hazard.Monitored wires must be properly insulated.
29
ARP01E2S 10.24.03
120 V AC120 V AC
ARP41SARP43S
SPDT, 8 PinDPDT, 8 Pin Cross Wired
Technical Data
Alternating RelayARP SeriesMotor Duplexor
Provides Shared Run Time for Two MotorsAlternating or Electrically Locked OperationLow Profile Selection Switch10 A Relay ContactsLED Status IndicationIndustry Standard Base Connection
DescriptionThe ARP Series is used in systems where sharedrunning time for two motors is desirable. Theselector switch allows selection of alternation oreither load for continuous operation. LED'sindicate the status of the output relay. Thisversatile series may be front panel mounted (BZ1accessory required) or 35 mm DIN rail mountedwith an accessory socket.
OperationAlternating: When the rotary switch is in the"alternate" position, alternating operation of LoadA and Load B occurs upon the opening of theprimary control switch. To terminate alternatingoperation and cause only the selected load tooperate, rotate the switch to position "A" to lockLoad A or position "B" to lock Load B.Duplexing (Cross Wired): Duplexing modelsoperate the same as the above alternating relays.When both the Primary Control S1 and Lag LoadS2 Switches are closed, Load A and Load Benergize simultaneously.
Approvals:
InputVoltage 120 V ACTolerance 120 & 230 V AC -20% ... +10%Line Frequency 50 ... 60 HzOutputType Electromechanical relayForm SPDT, or DPDT, or cross wired DPDTRating 10 A resistive at 240 V AC
7 A inductive at 120 V ACMaximum Voltage 250 V ACLife Mechanical -- 1 x 107
Full Load -- 1 x 106
ProtectionIsolation Voltage ≥ 1500 V RMS input to outputMechanicalMounting Plug-in socketPackage 3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm)Termination 8 pin octal or 11 pin magnalEnvironmentalOperating Temperature -20°C ... +60°CStorage Temperature -30°C ... +85°CWeight ≅ 5.6 oz (159 g)
Inches (Millimeters)
V = Voltage S1 = Primary Control SwitchS2 = Lag Load Switch LA = Load A LB = Load B
ARP41S
SPDT8 Pin
ARP43S
DPDTCrossWired
Note: Input voltage must be applied at all timesfor proper alternation. The use of a solid statecontrol switch for S1 may not initiate alternationcorrectly. S1 voltage must be from the samesupply as the unit's input voltage (see connectiondiagrams). Loss of input voltage resets the unit;Load A becomes the lead load for the nextoperation.
Relay contacts in the above diagram areisolated.
The DPDT 8-pin, cross wired option, allows extrasystem load capacity through simultaneousoperation of both motors when needed. Relaycontacts are not isolated.
Accessories
See accessory pages for specifications.
Panel mount kitP/N: BZ1
Hold down clipsP/Ns: PSC8 (NDS 8)
Octal8-pin socketP/N: NDS 8
DIN railP/Ns: C103PM (Al) 17322005 (Steel)
Part Number Input Voltage Output Form
Other Combinations are Available, 24 V AC, 230 V AC, 11 pin DPDT Dashed lines are internal connections.
www.ssac.com
30
LLC51E2S 10.14.03
www.ssac.com
Liquid Level ControlLLC5 SeriesDual Probe
Dual Probe Level Control for Conductive LiquidsOnboard Knob or Fixed Sensing up to 100KΩFill or Drain Operation AvailableLED Indicator Reduces Adjustment Time120 V AC Input Voltage5 A SPDT Isolated Contacts
DescriptionThe LLC5 provides dual level control in aconvenient octal plug-in package. Models areavailable for fill or drain operation. Transformerisolated AC voltage on the probes preventselectrolytic plating. Less than 1 mA of current isused to sense the presence of conductive liquidbetween the probes and common. On adjustableunits, the sensitivity adjustment eliminates falsetripping caused by floating debris and foamingagents.
OperationDrain (Pump Down Mode): When the liquid levelrises and touches the high level probe, the outputrelay energizes and remains energized until theliquid level falls below the low level probe. Theoutput relay then de-energizes and remains de-energized until the liquid again touches the highlevel probe.
Fill (Pump Up Mode): When the liquid level fallsbelow the low level probe, the output relayenergizes and remains energized until the liquidlevel rises and touches the high level probe. Theoutput relay then de-energizes and remains de-energized until the liquid level again falls below thelow level probe.
ControlType Resistance sensing for high & low level
detection of conductive liquidsSense Voltage 12 V AC at probe terminalsSense Resistance Factory fixed or adjustable to 100KΩSense Resistance Tolerance Adjustable - guaranteed range
Factory fixed +/-10%InputVoltage 120 V ACTolerance 120 & 230 V AC -20% ... +10%Frequency 50 ... 60 HzOutputType Electromechanical relayForm Isolated single pole double throw (SPDT) contactsRating 5 A resistive at 240 V AC; 1/10 hp at 240 V ACProtectionIsolation Voltage ≥ 1500 V RMS between input, output, & probeMechanicalMounting Plug-in socketTermination 8-Pin plug-inEnvironmentalOperating Temperature -20°C ... +60°CStorage Temperature -40°C ... +80°CWeight ≅ 6 oz (170 g)
HP = High Level Probe LP = Low Level ProbeC = Probe Common V = Voltage
Relay contacts are isolated. Dashed lines areinternal connections.
Connect common to conductive tank. Additionalprobe is necessary for non-conductive or insulatedtanks.
Approvals:
Level probeP/N: LLP 24
Accessories
Panel mount kitP/N: BZ1
Octal8-pin socketP/N: NDS 8
ElectrodeP/N: WCC 1138
Electrode withcommon connectionP/N: WCC 1138 3
See accessory pages for specifications.
Hold down clipsP/N: PSC8
Inches (Millimeters)
Also Available for 24 V AC, 230 V AC and with Fixed Sensitivity
Part NumberInput Voltage OperationDrainFill
SensitivityAdjustableAdjustable
Technical Data
120 V AC120 V AC
LLC54AALLC54BA
AC001E2S 10.14.03
P/N Range Inc. P0400 12 .05 ... 1s 0.1s P0400 13 .05 ... 2s 0.2s P0400 14 .05 ... 3s 0.5s P0400 15 0.1 ... 5s 0.5s P0400 82 0.1 ... 10s 1s P0400 17 1 ... 30s 5s P0400 83 1 ... 60s 10s P0400 19 2 ...120s 20s P0400 20 2 ...180s 30s P0400 21 0.1 ... 4m 0.5m P0400 22 0.1 ... 5m 0.5m P0400 23 0.1 ... 6m 1m P0400 24 0.1 ... 7m 1m P0400 25 0.1 ... 8m 1m P0400 26 0.1 ... 10m 1m P0400 27 0...10 MRD*
31
Inches (Millimeters)
P/N ValueP1004-198 25KΩP1004-199 50KΩP1004 95 100KΩP1004 17 500KΩP1004 16 1 MΩP1004 15 1.5 MΩP1004 14 2 MΩP1004 12 3 MΩP1004 13 5 MΩ
DescriptionPlastic dialsfor use withremoteVersa-Potand panelmountedMini-Pot.
P/N Value P1004 9 500KΩ P1004 10 1 MΩ P1004 31 3 MΩ
P/N ValueP1004 3 500KΩP1004 4 1 MΩ
P/N P0700 21
P/N P0700 7
P/N P0700 8
Ordering Table Series R-Value Range
Example P/N: VTP4F
SpecificationsRating 2W at 70°CTaper LinearShaft Rotation 280° +/-5°Tolerance +/-10%
B – 0.05 ... 3 sF – 0.5 ... 60 sJ – 2 ... 180 sN – 0.1 ... 10 mR – 0 ... 10 MRD*S – 0.1 ... 8 mX – All time range labels
VTP VTR
4 – 3 MΩ5 – 5 MΩ
DescriptionA high quality, industrial potentiometer for localadjustment of time delay. The shaft extendsthrough the timer's center hole for easy panelmounting. Use mini-mount bracket for standupmounting of timer. Adjustment by screwdriver ormini-knob. May be ordered with two 3 in. (7.6 cm)wires soldered to pot (clockwise increase) andfemale quick connect terminals on other ends byadding suffix X to end of part number.
Versa-Pot
Accessories–Adjustment Options and Dials
Q-Pot Mini-Knob
Mini-Pot VTP/VTR Lock Shaft
(Select one from each column)
DescriptionThe VTP Series mounts on modules with in-lineadjustment terminals. The VTR Series mounts onmodules with 90° adjustment terminals such asthe TSB and TSS Series. Rated at 0.25W at 55°C.Available in resistance values from 5K Ω to 5MΩ .
Inches (Millimeters)
Inches (Millimeters)
DescriptionA high quality cermet potentiometer for usewhen linearity and stability are important andwhen high temperature or harsh environmentsexist. Accepts Versa-Knob or Lock Shaft. Maybe ordered with two 8 in. (20.3 cm) wiressoldered to pot (clockwise increase) andfemale quick connect terminals on other endsby adding suffix X to end of part number.
Panel mountable, industrial potentiometerrecommended for remote time delay adjustment.The shaft is slotted for screwdriver adjustment andserrated for slip-proof finger adjustment. AcceptsVersa-Knob or Lock Shaft. May be ordered withtwo 8 in. (20.3 cm) wires soldered to pot (clockwiseincrease) and female quick connect terminals onother ends by adding suffix X to end of partnumber.SpecificationsRating 0.25W at 55°CTaper LinearShaft Rotation 300° +/-5°Tolerance +/-10%
Inches (Millimeters)
*Multiplier Reference Dial
DescriptionVersa-Knob is designed for 0.25 in (6.35 mm)shaft of Versa-Pot or Q-Pot. Semi-Gloss industrialblack finish.
Inches (Millimeters)
DescriptionBlack plastic control knob with fluted body forpositive finger contact and white index/dot forsetting accuracy. Mounts on 0.125 in. (3.2 mm)shaft of Mini-Pot.
Top View
X = Locked on shaft
DescriptionFits 0.25 in. (6.35 mm) potentiometer shafts.Locks by tightening nut onto four tapered/slottedfingers. Pressure on shaft locks control againstmis-adjustment. Nickel plated brass finish.
Versa-Knob
Inches (Millimeters)
Time Adjustment Dials
Description
SS = Set Screw
SS = Set Screw
Specifications Rating 0.25W at 55°C Taper Linear Shaft Rotation 300° +/-5° Tolerance +/-10%
www.ssac.com
32
SA001E2S 01.22.04
P/N: PSCRB8
P/N: PSC8 PSC11
Accessories–Sockets
Hold-Down Brackets
Description8 pin surface mount socket withbinder head screw terminals.Rated 10 A at 300 and 600 V AC.
P/N: P1011 6
Surface Mount Sockets DIN Rail or Surface Mount Sockets
8 Pin Octal Socket8 Pin Octal Socket
DescriptionMay be surface mounted with two #6 (M 3.5 x 0.6) screws or snaps ontoa 35 mm DIN rail by means of a spring mechanism which also allows foreasy removal. Screw terminals with captive wire clamps accept up to two#14 AWG (2.45 mm2) wires. Rated 10 A at 300 V AC.
P/N: NDS 8
DescriptionSame as NDS 8 except 11 pin
P/N: NDS 11
8 Pin Octal Socket
11 Pin Magnal Socket
DescriptionIndustry standard 35 mm aluminumor steel DIN rail. C103PM aluminumrail is available in 36 in. (91.4 cm)lengths. 17322005 steel rail isavailable in 78 in. (2 m) lengths.
P/N: C103PM (Al) 17322005 (Steel)
DescriptionSecurely mounts SSAC 8 & 11pin plug in controls in anyposition. Also provides protectionagainst vibration. Designed foruse with P1011 6 socket. Comesin sets of two.
DIN Rail
Part Number Rating Termination
DescriptionSecurely mounts plug incontrols in any position. Alsoprovides protection against vibration.Select the PSC8 for use withNDS8 or the PSC11 for use withNDS11 sockets. Comes in sets of two.
Description8 pin DIN rail or surface mount socket. OT08PC is rated at 10 A at600 V AC and has pressure clamp terminals. For use with AWG 12to 22 (3.2 to 0.33 mm2) wire sizes.
Inches (Millimeters)
Inches (Millimeters)
Inches (Millimeters)
Inches (Millimeters)
Inches (Millimeters)
www.ssac.com
OT08PC 600 V AC Pressure Clamps
33
MAC01E2S 01.16.03
Female Quick Connect TerminalsDescriptionFemale screw adaptor terminal designed for use with all modules with0.25 in. (6.35 mm) male quick connect terminals. Screw terminalaccepts ring or spade terminals.
L = 0.55 (41.0)W = 0.32 (8.1)
P/N P1023 20
Metal Oxide Varistors
DIN Rail Mount
Mini-Mount/Standard Mount
Accessories–Mounting Methods, Terminals and Varistors
Quick Connect Screw Adaptor
Inches (Millimeters)
DescriptionThese 0.25 in. (6.35 mm) female terminals are constructedwith an insulator barrel to provide strain relief.
DescriptionAllows any 2 x 2 in. (50.8 x 50.8 mm) or 2 x 3 in. (50.8 x 76.2 mm) SSACmodule to be mounted on a 35 mm DIN type rail. Comes complete withmounting hardware for 0.75 in. (19 mm) and 1 in. (25.4 mm) thickpackage.
P/N Wire Size P1015 13 AWG 10/12 (5.3/3.2 mm2) P1015 64 AWG 14/16 (2.5/1.3 mm2) P1015 14 AWG 18/22 (0.93/0.33 mm2)
Inches (Millimeters)
L = 0.83 (21.1)W= 0.3 (7.6)
Inches (Millimeters)
Panel Mount Kit
DescriptionProvides an easy method of through-the-panel mounting of 1.78 x 2.39 in.(60.7 x 45.2 mm) 8 or 11 pin plug-intimers, flashers, and other controls.May be mounted in panels up to 0.125in. (3.2 mm) thick. Includes two clampsand two screws.
P/N BZ1 Inches (Millimeters)
Illustrates panel opening size required to mount BZ1.
D = 0.25(6.35)(P1023 7)
D = 0.19(4.8)(P1023 6)
DescriptionProvides a convenient method of mounting 2 x 2 x 1.21 in. (50.8 x50.8 x 30.7 mm) or 2 x 3 x 1.5 in. (50.8 x 76.2 x 38.1 mm) modules.The 90° orientation of mounting slots makes installation/removal ofmodules quick and easy. The P1023 6 secures to module with a #8(M4 x 0.7) screw. The P1023 7 secures to 2 x 2 x 1.21 in. (50.8 x50.8 x 30.7 mm) module with Mini-Pot for local adjustment. Madefrom steel with a cadmium surface finish.
P/N
Max. Impulse Current80/20 us current wave
(A)
Max. OperatingVoltage
DC (V) AC (V)
Varistor Voltage at1 mA DC Test CurrentMin. (V) Max. (V)
Peak Clamping Voltagewith 80 us wave
Vc (V) Ip (A)
Capacitance(pF)
Size(mm)
P1012 27P1012 25P1012 3P1012 6
200200369369
150150275275
1200450012004500
212212389389
268268515475
395395775710
10501050
15080085450
714714
LW
P/N P1015 18
S, E, Series Adaptor for Screw Mounting
22.5 mm width P/N 1SVR 430 029 R 0100W
D
Mounting Method#8 (M4 x 0.7) screw
Mini-Pot
Mounting Hole Size0.19 in. (4.8 mm)
0.25 in. (6.35 mm)
P/NP1023 6P1023 7
www.ssac.com
34
MP001E2S 05.22.03
CM-GM-1
Part Number Type Description1SVR 450 056 R 6000 CM-KH-3 Compact support for 3 bar electrodes1SVR 450 056 R 7000 CM-AH-3 Distance plate for 3 bar electrodes1SVR 450 056 R 8000 CM-GM-1 Counternut for 1" thread
Bar electrodes (X 12 CR Mo S 17) with sleeve (Lupulen 6011 L, suitableup to max. 60° C)
P/N 1SVR 402 902 R 0000
Note: The terminal of the electrode should be sealed to preventcorrosion. Protects electrode cables from thunderstorms.
P/N: WCC 1138 3
P/N: WCC 1138
P/N: Y P0700-241
Accessories
Liquid Level Control Electrodes and Probes
DescriptionComposed of an alumina insulator and metalparts made of number 300 series nonmagneticstainless steel. These internally conductiveglass-sealed electrodes are capable of up to2500 PSI at 21°C and 371°C at 1 atmosphere.
A = 3/8-18 PTF-SAE Short DrysealH = HexagonalX = Full Thread
Inches (Millimeters)
Mechanical Outline and Accessories for mecotron® and timetron® Controls
CT-S Series22.5 mm
CT-S Series:Screw Connection
CT-E Series22.5 mm
CT-E Series:Screw ClampConnections
Sealable cover
Sealable cover forCT-S series 22.5 mm wide
Part Number DescriptionWCC 1138 Electrode (UL Recognized)WCC 1138 3 Electrode with Common ConnectionLLP 24 Stainless Steel Probe
DescriptionThreaded stainless steel probe measuring 24 in. (61 cm) long.Designed for use with WCC 1138 and WCC 1138 3.
Overhead electrode + rubber grommet
Part Number Length1SVR 450 056 R 0000 12 in. (300 mm)1SVR 450 056 R 0100 24 in. (600 mm)1SVR 450 056 R 0200 39 in. (1000 mm)
Marker label
P/N 1SVR 366 017 R 0100
P/N 1SVR 430 005 R 0100
Screw-in bar electrodes
Compact Support
CM-KH-3
thread M4
SW36
counternut GM-1"
distance plate AH-3
electrodes
0.16 (4)
1.57 (40)
1.77
(45)
0.79
(20)
1.57 (40)
1.02 (26) 0.31 (8)
0.16 (4) 0.26 (6.5)
Inches (Millimeters)
0.35 (9)
0.59 (15)
1" thread Gscrew terminal connectionsM16 screw cable gland
CM-AH-31.02 (26)
0.16
(4)
www.ssac.com
ABB
35
APRV1E2S 10.24.03
www.ssac.com
ABB SSAC products have been designed, developed, and tested in accordance with all relevant CE standards.
When UL/CSA approvals are indicated, ABB SSAC products are UL Recognized (UL Listed for DLM and WVM Series)under File Number E57310 and CSA Certified under File Number LR57415. UL Recognized and Listed products are tested tothe requirements of UL508 - Industrial Control Equipment. CSA Certified products are tested to the requirements of C22.2Number 14 - Industrial Control Equipment.
UL ListedThe UL Listed Mark on a product indicates that samples of that complete product have been tested by UL to nationally
recognized Safety Standards and found to be free from reasonably foreseeable risk of fire, electric shock and related hazards.
UL RecognizedUL's Component Recognition Service covers the testing and evaluation of component products that are incomplete or
restricted in performance capabilities. These components will later be used in complete end-products or systems Listed byUL.
CE Approvals
Product Standards:EN50082-2 EN60730EN61010-1 (DLM and WVM only)
Electromagnetic Compatibility:89/336/EEC
Low Voltage Directive:93/68/EEC
Low Voltage Directive Tests:EN60730EN61010-1 (DLM and WVM only)
CE Conditions of Acceptability
Products Containing DIP Switches:Power must be removed from the unit when aswitch position is changed.
Products with Solid State Output:Loads rated above 1 A, must be evaluated forCE use when used with solid state outputproducts.
The items shown in this catalog are some of our most popular products and are available through authorized Distributorsthroughout the world. Many other products, part numbers, functions, and options are available. Consult our WebCatalog forcomplete listings: www.ssac.com
As part of the continuous review of our product line, ABB SSAC reserves the right to make design and/or specification changeswithout notice.
UL and CSA Approvals
Product standard: parts of IEC 255, IEC 1812-1 (timetron)IEC 255 part 6 (mecotron)
Electromagneticcompatibility: 93 / 68 / EWGLow voltage directive: 93 / 68 / EWG
Shock/vibration: IEC 68 part 2-6: 10 GEnvironmental tests: IEC 68 part 2-30: 24 h cycle, 55°C, 93% rel, 96 hIsolation tests:Overvoltage category: III to VDE 0110, IEC 664; C to IEC 255-5Pollution category: III to VDE 0110, IEC 664; C to IEC 255-5
Test voltage: 2.5 kV/ 50 Hz/ 1 min. between all isolated circuits
Special standards and tests
The timetron range has been designed and developed in accordancewith all relevant timer norms and standards.
®timetron CT-D, CT-E and CT-S Series: Rated insulation voltage to VDE 0110, IEC 947-1 between isolated circuits depending on the supply voltage
Supply voltage up to 240 V: 300 VSupply voltage up to 440 V: 500 V
Standards for CT-D, CT-E and CT-S Series timetron Timers ®
36
INDX1E2S 01.14.04
TDML24DL ................................. 10TDML120AL ............................... 10TDR4A11 .................................... 11TDR4A22 .................................... 11TDR4A33 .................................... 11TDS24AL .................................... 10TDS24DL .................................... 10TDS120AL .................................. 10TDS120ALD ................................ 10TDSH120AL ................................ 10TDSL120AL ................................ 10TDSL120ALD .............................. 10TDU3000A .................................. 14TDU3001A .................................. 14TDUH3000A ............................... 14TDUH3001A ............................... 14TDUL3000A ................................ 14TDUL3001A ................................ 14TMV8000.....................................15TRDU24A2 .............................. 2,3TRDU24A3 ................................ 2,3TRDU120A1 .............................. 2,3TRDU120A2 .............................. 2,3TRDU120A3 .............................. 2,3TRDU230A1 .............................. 2,3TRDU230A2 .............................. 2,3TRDU230A3 .............................. 2,3TRU1 ............................................ 6TRU2 ............................................ 6TRU3 ............................................ 6TS1421 ....................................... 16TS1422 ....................................... 16TS1423 ....................................... 16TS1424 ....................................... 16TS2421 ....................................... 16TS2422 ....................................... 16TS2423 ....................................... 16TS2424 ....................................... 16TSB421 ....................................... 16TSB422 ....................................... 16TSB423 ....................................... 16TSB424 ....................................... 16TSS421 ....................................... 16TSS422 ....................................... 16TSS423 ....................................... 16TSS424 ....................................... 16TSU2000 ..................................... 15VTP/VTR ..................................... 31WCC1138 X ................................ 34WVM011AH ........................... 20,21WVM011AL ........................... 20,21WVM011M ............................ 20,21WVM611AH ........................... 20,21WVM611AL ........................... 20,21WVM611M ............................ 20,21WVM911AH ........................... 20,21WVM911AL ........................... 20,21WVM911M ............................20,21
017322005 .................................. 321SVR 366 017 R 0100 ............... 341SVR 402 902 R 0000 ............... 341SVR 430 005 R 0100 ............... 341SVR 430 010 R 0200 ................. 41SVR 430 029 R 0100 ............... 331SVR 430 102 R 0100 ................. 81SVR 430 103 R 0200 ................. 81SVR 450 056 R 0000 ............... 341SVR 450 056 R 0100 ............... 341SVR 450 056 R 0200 ............... 341SVR 450 056 R 6000 ............... 341SVR 450 056 R 7000 ............... 341SVR 450 056 R 8000 ............... 341SVR 500 020 R 0000 ................. 71SVR 500 100 R 0000 ................. 91SVR 550 019 R 0000 ............... 121SVR 701 800 R 1000 .............. 4,8ARP41S ...................................... 29ARP43S ...................................... 29ASQUA3 ..................................... 13ASQUD3 ..................................... 13ASTUA3 ...................................... 13ASTUD3 ...................................... 13BZ1 ............................................. 33C103PM ..................................... 32CT-ERD ........................................ 9CT-ERS ......................................... 8CT-MFD ........................................ 7CT-MFS ..................................... 4,5CT-MKE ...................................... 12DLM011 ...................................... 23DLM611 ...................................... 23DLM911 ...................................... 23DSQUA3 ..................................... 13DSQUD3 ..................................... 13DSTUA3 ...................................... 13DSTUD3 ..................................... 13ECS20BC ................................... 25ECS21BC ................................... 25ECS40BC ................................... 25ECS41BC ................................... 25FA155 .......................................... 19FA155 2 ....................................... 19FB120A ....................................... 19FS126 ......................................... 18FS126RC .................................... 18FS127 ......................................... 18FS146 ......................................... 18FS146RC .................................... 18FS155 30RF ................................ 19FS155 30T .................................. 19FS312 ......................................... 18FS324 ......................................... 18FSU1000 ..................................... 18FSU1003 .....................................18FSU1004 ..................................... 18FSU1005 ..................................... 18LCS10T12 ................................... 28
LLC54AA .................................... 30LLC54BA .................................... 30LLP 24 ........................................ 34LPM12 ........................................ 28LPMG12 ..................................... 28NDS 8 ......................................... 32NDS 11 ....................................... 32OT08PC ...................................... 32P0400 XX .................................... 31P0500 153 .................................. 21P0600 11 .............................. 21-24P0700 XX .................................... 31P0700 241 ............................ 21-24P1004 XX .................................... 31P1011 6 ...................................... 32P1011 38 .................................... 21P1012 XX .................................... 33P1015 XX .................................... 33P1023 XX .................................... 33PCR10 ........................................ 19PCR11 ........................................ 19PLMU11 ..................................... 22PSC8 .......................................... 32PSC11 ........................................ 32PSCRB8 ..................................... 32RLM611 ...................................... 24RLM911 ...................................... 24RS4A11 ...................................... 17RS4A22 ...................................... 17RS4A33 ...................................... 17SCR430T .................................... 19SCR490D ................................... 19TCSA5 ........................................ 27TCSA10.......................................27TCSA20 ...................................... 27TCSA50 ...................................... 27TCSGAA ..................................... 26TCSGAB ..................................... 26TCSHAA ..................................... 26TCSHAB ..................................... 26TDB24AL .................................... 10TDB24DL .................................... 10TDB120AL .................................. 10TDB120ALD ............................... 10TDBH120AL ............................... 10TDBL120AL ................................ 10TDBL120ALD ............................. 10TDI24AL ...................................... 10TDI24DL ..................................... 10TDI120AL .................................... 10TDIH120AL ................................. 10TDIL120AL .................................. 10TDM12DL ................................... 10TDM24AL ................................... 10TDM24DL ................................... 10TDM120AL ................................. 10TDMH120AL ............................... 10TDML12DL ................................. 10
Index of Part Numbers
www.ssac.com
Part Number Page Part Number Page Part Number Page
Low Voltage Products & Systems
ABB Inc.1206 Hatton RoadWichita Falls, TX 76302Tel. 888-385-1221
940-397-7000Sales Fax 800-726-1441Tech Fax 940-397-7085Web www.abb-control.com
AC 1008-2 1TRC001008C0202November 2003
SSACABB Inc.PO Box 1000Baldwinsville, NY 13027Tel. 315-638-1300Tech. Asst. 800-377-SSAC (7722)Fax 315-638-0333Data Fax 315-638-7158Web www.ssac.com
ABB Inc3299, J.B. DeschampsLachine, QC H8T 3E4CanadaTel:
866-460-3300 (Ontario) 866-222-8368 (Calgary) 604-777-5477
800-567-0283 (Quebec Head Office)
(British Columbia)