8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible...

6
8-10 Electrical System YOUR INNOVATIVE MODULAR SOLUTIONS.

Transcript of 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible...

Page 1: 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible Mesh Jumper Floor Power Entries Components - See System Specifications on following

8-10 Electrical System

Y O U R I N N O V A T I V E

M O D U L A R S O L U T I O N S .

Page 2: 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible Mesh Jumper Floor Power Entries Components - See System Specifications on following

Mastering Complexity

P A N E L S Y S T E M - I N S P I R E D S O L U T I O N

Panel System Compatibility

The 8 and 10 Wire Systems are intuitively designed for panel and desking system compatibility, so that

receptacle location and mounting hardware remain unchanged for optimal installation. Offered in 3, 4,

or 6 circuits, these systems overall, lower total cost and deliver the flexibility demands of today’s office

furniture industry.

A typical distribution assembly of an 8 or 10 wire system consists of a Distribution Harness, Jumper, and

Receptacle(s) with optional Floor and Ceiling Power Entries. It serves to provide point of attachment and

electrical connection for duplex receptacles, flexible panel connectors, and power entry components.

Each component offers a variety of options to fit specific needs and workplace requirements. Choose from

Shared Neutral 8 wire 4-2-2 or 10 wire 6-2-2 and Independent Neutral 8 wire 3-3-2 or 10 wire 4-4-2

(L-N-G) options.

Approved for UL 1286 or UL 183 applications and approved power infeed options for m etropolitan areas

(New York).

From simple to complex, the 8 and 10 Wire Systems were built for the

ultimate capacity and field reliability. This powerful non-directional

system allows flexible power connection suitable for panel and desking

systems. Available in 3, 4, or 6 circuits, the 8 and 10 Wire Systems

eliminate the need to change mounting hardware or receptacle

location and in the same space as most 8 wire systems.

8 -1 0 E L E C T R I C A L S Y S T E M P R O V I D E S :

8 - 1 0 E L E C T R I C A L S Y S T E M S

Page 3: 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible Mesh Jumper Floor Power Entries Components - See System Specifications on following

Specifications

• System Rating 20A/120V

• 15 or 20 Amp Duplex Receptacle Options

• 2.1A/10.5W USB Module Options

• Shared or Independent Neutral Wiring Systems

(All Shared Neutrals use 10 gauge wire, rated at 35

Amps - See Wire Schematics Sheet for Details)

• Shared: 8 Wire (4-2-2) or 10 Wire (6-2-2)

• Independent: 8 Wire (3-3-2) or 10 Wire (4-

4-2)

• 8 Wire (4-2-2) Configuration: Up to 52

Receptacles Per Infeed

• 8 Wire (3-3-2) Configuration: Up to 39

Receptacles Per Infeed

• 10 Wire (6-2-2) Configuration: Up to 78

Receptacles Per Infeed

• Receptacle Decora Face Thicknesses Available:

.990”, 1.115” & 1.655” Top Spring Mount

(Receptacles work for both 8 and 10 Wire)

• USB Charging Module Decora Face Thickness

Available: 1.115”, 1.25” & 1.655” Top Spring

Mount

• Wire Systems Components Include Distribution

Harness, Jumper, Ceiling Power Entries,

Floor Power Entries, Receptacles (Each Sold Seperately)

• Jumper Conduits Options: Oval Extra-Flex,

Liquid-Tight, and Extra Flex

• Standard Distribution Panel Lengths: 24” 30”,

36”, 42”, 48”, 54”, 60” & 72”

• For Panel-to-Panel Connections Use 15”

Flexible Mesh Jumper for All Panel Lengths

• Comply with UL 1286 and UL 183 Approved

Electrical Distribution Assembly- Mechanically attached to the panel base or table. It serves to provide point of attachment and electrical

connection for duplex receptacles, flexible panel connectors, and power entry components.

Duplex Receptacles-Plugs into and is mechanically attached to the electrical distribution assembly. The receptacle is internally arranged to

connect to the circuitry designated by the symbol on its face.

Jumper-Utilized to electrically connect electrical dis-tribution assemblies.

Floor Power Entry- Used to connect the electrical distribution system to the building power network at a floor level junction box or similar device.

Ceiling Power Entry-Used to connect the electrical distribution system to the building power network at an above ceiling level junction box or

similar device. The Ceiling Power Entry is installed by plugging directly into an electrical distribution assembly. The procedure is similar to jumper

installation and the connection point is the same.

F E A T U R E S :

Applications

Panel Systems

Desking Systems

Harness Flexible Mesh Jumper Floor Power Entries

Components - See System Specifications on following pages for additional details

Ceiling Power Entries

S Y S T E M S P E C I F I C A T I O N S - 8 -10 W I R E S Y S T E M O V E R V I E W

8 - 1 0 E L E C T R I C A L S Y S T E M S

Receptacles USB Module Receptacle

2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com 2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com

Page 4: 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible Mesh Jumper Floor Power Entries Components - See System Specifications on following

S Y S T E M S P E C I F I C A T I O N S - J U M P E R C O M P O N E N T S

O VA L - E X T R A F L E X C O N D U I T L I Q U I D - T I G H T C O N D U I T

J U M P E R D I S T R I B U T I O N L E N G T H S

D I S T R I B U T I O N W I T H C H A N N E L

S P R I N G O R S Q U E E Z E L A T C H J U M P E R S A V A I L A B L E

E X T R - F L E X C O N D U I T

S Y S T E M S P E C I F I C A T I O N S - H A R N E S S & S Y S T E M C O M P O N E N T S

2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com 2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com

Page 5: 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible Mesh Jumper Floor Power Entries Components - See System Specifications on following

• Plug -to-Plug in Extra-Flex Conduit

• Distribution

• Plug-to-Plug in Liquid-Tight Conduit

• Centermount distribution

• Plug-to-Plug in Flexible Mesh - Maximum length 29”

(24” of exposed Mesh)

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280003280273

280001280000

580003580273

580001580000

280252280311

280251280253

280084280307

280086280085

580084580307

580086580085

280262280312

280266280265

280272280262

280271280270

N/AN/A

N/AN/A

580262580312

580266580265

580252580311

580251580253

D E S C R I P T I O N

D I S T R I B U T I O N H A R N E S S E S

J U M P E R S

W I R E S Y S T E M 12 6 8 S E R I E S # / 18 3 S E R I E S #

Products are keyed so that the distribution harnesses and all componenets must be the same version(ie: Shared or Independent) to plug together

• Plug-to-Open in Extra-Flex Conduit (Standard length

144” + 8” Leads)

• Plug-to-Open in Liquid-Tight Conduit (Standard length

144” + 8” Leads)

• .990” Reversible in the field, in liguid tight conduit -

Standard length 72” + 8” Leads

• 1.655” Reversible in the field, in liguid tight conduit -

Standard length 72” + 8” Leads

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280005280277

280007280006

580005580277

580007580006

280003280273

280001280000

580003580273

580001580000

28008280305

280010280009

58008580305

580010580009

280464280466

280463280462

580464580466

580463580462

D E S C R I P T I O N

C E I L I N G P O W E R E N T R I E S

F L O O R P O W E R E N T R I E S

W I R E S Y S T E M 12 6 8 S E R I E S # / 18 3 S E R I E S #

• Right or left hand available, in liguid tight conduit -

Standard length 72” + 8” Leads

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280054280285

280056280055

580054580285

580056580055

• .990” 15 Amp Receptacle Decorator face - top spring

mount

• 1.115” 15 Amp Receptacle Decorator face - top spring

mount

• 1.115” USB Module Decorator face - top spring mount

• 1.250” USB Module Decorator face - top spring mount

• 1.655” USB Module Decorator face - top spring mount

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280022

280023

280452

280453

280714

280720

280712

280718

280710

280716

580452

580453

580714

280720

580712

580718

580710

580716

580022

580023

R E C E P T A C L E S & U S B M O D U L E S

• 1.655” 15-15/20 Amp Receptacle Decorator face -

top spring mount

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280233

280239

580233

580239

2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com 2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com

Page 6: 8-10 Electrical System - Dekko€¦ · Applications Panel Systems Desking Systems Harness Flexible Mesh Jumper Floor Power Entries Components - See System Specifications on following

D E S C R I P T I O N W I R E S Y S T E M 12 6 8 S E R I E S # / 18 3 S E R I E S #

2505 Dekko Drive, Garrett, IN 46738 | P 203.924.6617 | Dekkopower.com REV082819

280324280326

280323280325

• Hardwired Junction Box for metropolitian areas (NY)

• Special application receptacles - International Outlets

(available for most countries)

• 2 Port Coupler (Straight-Thru Block)

• 4 Port Coupler (Quad Block)

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280345

280346

280391

280392

280046

2800040

580046

5800040

580391

580392

580345

580346

S P E C I A L A P P L I C A T I O N S

N/AN/A

N/AN/A

• Special application receptacles - Twist -Lock 8 Wire 4-2-28 Wire 3-3-2

10 Wire 6-2-210 Wire 4-4-2

280041280044

280035280038

580041580044

580035580038

Products are keyed so that the distribution harnesses and all componenets must be the same version(ie: Shared or Independent) to plug together