5HH-SPEC

4
P R O D U C T D A T A S H E E T CORNELL PUMP COMPANY 5 HH MOUNTING OPTIONS Close Coupled Electric - Cornell’s Energy Efficient Design Frame Mount Cornell F16 Cornell F18 Engine Bracket Cornell EM16 (SAE 1, 2, 3, 4) Cornell EM18 (SAE 1, 2, 3, 4) Redi-Prime ® Self Priming System - Available STANDARD SPECIFICATION Discharge - 5 inch flanged discharge Suction - 8 inch flanged suction Balance Line Impeller - Enclosed silicon bronze Volute - Right hand tangential discharge, four positions Mechanical Seal or Traditional Packing - Single type 1 carbon ceramic mechanical seal: Cycloseal ® design, run-dry available Materials of Construction - Cast iron bronze fitted - Other materials available 175 - 350 Feet TDH 750 - 2500 GPM FEATURES & BENEFITS Cornell’s Tradition of Excellence: Highest Quality Products Experience - Over 50 years in the centrifugal pump business Optimum Hydraulics - In house engineering staff and test lab facilities Strong Local Dealer Support - Our agricultural products are sold only through authorized dealerships - Dealerships provide full service to customers from sales to replacement parts - Dealers maintain and improve their knowledge at educational activities like Cornell’s “Pump School” Exceptional Design: Efficiency - Effectively converts energy into fluid flow and pressure Long Product Life - Thick walled castings - Heavy duty shafts - 20,000 hour bearings - Replaceable wear rings and shaft sleeves - Reduced thrust load through design and balance lines where appropriate PRODUCT AVAILABILITY Quick Ship - Finished Product Regularly Stocked - Specific Configuration, Specific Trim (48 Hours) Preferred Pump - Finished Components Regularly Stocked - Various Configurations, Variable Trim (10 business days) Specialty Pump - Cornell Pump Company will design and manufacture a variation of this pump specifically designed for your application

description

5HH-SPEC

Transcript of 5HH-SPEC

Page 1: 5HH-SPEC

P R O D U C T D A T A S H E E T

CORNELL PUMP COMPANY5 HH

MOUNTING OPTIONS

• Close Coupled Electric- Cornell’s Energy Efficient Design

• Frame MountCornell F16 Cornell F18

• Engine BracketCornell EM16 (SAE 1, 2, 3, 4)Cornell EM18 (SAE 1, 2, 3, 4)

• Redi-Prime® Self Priming System - Available

STANDARD SPECIFICATION

Discharge - 5 inch flanged dischargeSuction - 8 inch flanged suctionBalance LineImpeller - Enclosed silicon bronzeVolute - Right hand tangential discharge, four positionsMechanical Seal or Traditional Packing - Singletype 1 carbon ceramic mechanical seal: Cycloseal®

design, run-dry availableMaterials of Construction

- Cast iron bronze fitted- Other materials available

175 - 350 Feet TDH750 - 2500 GPM

FEATURES & BENEFITS

• Cornell’s Tradition of Excellence:• Highest Quality Products• Experience

- Over 50 years in the centrifugal pump business• Optimum Hydraulics

- In house engineering staff and test lab facilities • Strong Local Dealer Support

- Our agricultural products are sold only through authorized dealerships

- Dealerships provide full service to customers from sales to replacement parts

- Dealers maintain and improve their knowledge at educational activities like Cornell’s “Pump School”

• Exceptional Design:• Efficiency

- Effectively converts energy into fluid flow and pressure

• Long Product Life- Thick walled castings- Heavy duty shafts- 20,000 hour bearings- Replaceable wear rings and shaft sleeves- Reduced thrust load through design and balance

lines where appropriate

PRODUCT AVAILABILITY

• Quick Ship- Finished Product Regularly Stocked - Specific Configuration, Specific Trim

(48 Hours)• Preferred Pump

- Finished Components Regularly Stocked - Various Configurations, Variable Trim

(10 business days)• Specialty Pump

- Cornell Pump Company will design and manufacture a variation of this pump specifically designed for your application

Page 2: 5HH-SPEC

PERFORMANCE CURVES

Cornell Pump CompanyP.O. Box 6334

Portland, Oregon 97228-6334Web: www.cornellpump.com

Phone: (503) 653-0330 • Fax: (503) 653-0338

Note:Curves alsoavailable in 1200 and various RPM

MOTOR DIMENSIONS

PUMP DIMENSIONSMOUNT AK Fig. A AR B C CP D DA DD E F H L P R S T U V X Y Z LP KEYWAYCC 12.5 1 - - - - - - - 16.25 - - - - - - 0.44 3.59 - - 11 10.56 10.25 10.81 -

16.5 1 - - - - - - - 16.25 - - - - - - 0.44 3.59 - - 11 10.56 10.25 10.81 -F16 - 2 12 - 12.88 28.83 - 9.75 - 16.25 5.12 10.38 0.81 10.97 0.88 - 0.44 3.59 2 4.5 11 10.56 10.25 - .50 X .25F18 - 2 12 - 12.88 29.84 - 10.5 - 16.25 5.12 10.38 0.81 11.47 0.88 - 0.44 3.59 2.5 4.5 11 10.56 10.25 - .62 X .31EM16 3 - 5.25 - 28.83 37.39 - 16.25 13 - - - - - 16.77 0.44 3.59 2 - 11 10.56 10.25 - .50 X .25EM18 - 3 - 5.25 - 29.84 38.41 - 16.25 13 - - - - - 16.77 0.44 3.59 2.5 - 11 10.56 10.25 - .62 X .31

16.38" DIA.

16" DIA.

15" DIA.

14" DIA.

13" DIA.

85

85

83

83

80

80

757060

200 HP

150 HP

125 HP

100 HP

75 HP

N SSolids Dia.

HP x .746 = KWGPM x 3.785 = Liters/MinuteGPM x .227 = Cubic Meters/HourInches x 25.4 = MillimetersFeet x .305 = Meters

No. vanesDischargeSuction

DOUBLE VOLUTE MOUNTING CONFIG.: CC, VM, F, VF, EM, VC

1785

6/99

hors

epow

er a

nd/o

r pe

rfor

man

ce a

djus

tmen

ts.

Oth

er m

ount

ing

styl

es o

r liq

uids

may

req

uire

coup

led

elec

tric

con

figur

atio

n w

ith p

acki

ng.

Per

form

ance

s sh

own

are

for

cool

wat

er, c

lose

-

65"8"11971.0"ENCLOSEDVARIOUS

StyleSpeed Impeller Dia.

300

325

90

10 FT.(3.0 M.)

12 FT.(3.7 M.)

15 FT.(4.6 M.)

20 FT.(6.1 M.) NPSH REQUIRED275

250

20

30

40

50

60

80

U.S. GALLONS PER MINUTECAPACITY

100 200 300 400 500 600 700

CUBIC METERS PER HOUR

TO

TA

L D

YN

AM

IC H

EA

D

ME

TE

RS

70

FE

ET

30000 2500200015001000500

225

200

175

150

125

100

75

50

5 HH1800 RPM

MOTOR AKFRAME DIM. A B D E F H AB BA LC213-5 8.5 9.5 8 5.25 4.25 7 0.41 7.94 4.5 14254-6 8.5 11.25 11.25 6.25 5 10 0.53 9.5 5 18284-6 12.5 12.25 12.25 7 5.5 11 0.53 11.37 5 21324-6 12.5 14.25 13.75 8 6.25 12 0.66 12.22 5.5 22364-5 12.5 15.75 14 9 7 12.25 0.66 13.2 6.12 24404-5 12.5 18.5 16.62 10 8 13.75 0.81 16.39 6.88 30444-5 16.5 21.5 19.5 11 9 16.5 0.81 19.06 7.5 31

Figure 1 Figure 2

Figure 3

Page 3: 5HH-SPEC

P R O D U C T D A T A S H E E T

PUMP SPECIFICATIONS

• Size: 5HH - 5" discharge x 8" suction with 125# cast iron flanges.

• Casing: Cast Iron.• Impeller: Enclosed - 6 vane. Handles .75"

diameter solids.• Wear Rings: Replaceable. (Double wear rings

available). • Seal: Cornell’s patented Cycloseal® design with

Run-Dry oil lubrication system. John Crane T-2 single mechanical seal with Viton® elastomers, stainless steel hardware and tungsten- vs. silicon-carbide seal faces for abrasion resistance.

• Check Valve: SwingFlex® Val-Matic®.• Shaft Sleeve: Heat treated 416 stainless steel.• Bearings: Heavy duty, grease lubricated, deep

groove ball bearings, with a minimum of 50,000 hours bearing life.

• Hardware: Stainless steel float linkage. A positive seating vacuum priming valve prevents water carry-over to the vacuum, pump or atmosphere.

• Vacuum Pump - 50 SCFM Maximum.

CORNELL PUMP COMPANYModel 5HH-F Redi-Prime®

CORNELL

SUCTION SPOOL

VACUUM PUMP

DISCHARGE CHECKVALVE

IMPELLER

VOLUTE

BACKPLATEBEARING FRAME

BEARINGS

WEAR RING

SUC

TIO

N

DISCHARGE

BALL VALVE

AIR/WATER SEPARATOR

Page 4: 5HH-SPEC

R

2000 RPM

1900 RPM

1800 RPM

1700 RPM

1600 RPM

70

80

80

85

83

75

83

85

TO

TA

L D

YN

AM

IC H

EA

D

40

For NPSHR, refer to standard pump curve.Efficiency shown is pump hydraulic efficiency.

Suction Lift plus all Friction Losses in the suction line.Total Suction Lift is equal to Static (vertical)

at Sea Level with 60 deg. Fahrenheit water.Data shown is approximate pump performance

DOUBLE VOLUTE MOUNTING CONFIG.: F, EM

5 FT (1.5 M)

100

125

325

275

225

175

700

FE

ET

CUBIC METERS PER HOUR

600500400300200100

110

100

90

80

70

60

50

ME

TE

RS

U.S. GALLONS PER MINUTE3000

CAPACITY0 2500200015001000500

150

350

300

250

200

125 HP

200 HP

150 HP

175 HP

240 HP

375

65" 8"3200.75"ENCLOSED 16.38"

StyleSpeed Impeller Dia. N SSolids Dia.

HP x .746 = KWGPM x 3.785 = Liters/MinuteGPM x .227 = Cubic Meters/HourInches x 25.4 = MillimetersFeet x .305 = Meters

No. vanesDischargeSuction

VARIOUS

2/15/01

requ

ire p

erfo

rman

ce a

djus

tmen

ts.

Oth

er li

quid

s or

mou

ntin

g co

nfig

urat

ions

may

fr

ame

mou

nted

con

figur

atio

n w

ith C

yclo

seal

.P

erfo

rman

ces

show

n ar

e fo

r co

ol w

ater

,

not i

nclu

de d

isch

arge

che

ck v

alve

loss

es.

vacu

um p

ump.

Per

form

ance

cur

ve d

oes

Add

1.5

HP

for

belt

driv

en d

iaph

ragm

20 FT (6.1 M)

15 FT (4.6 M)

10 FT (3.0 M)

25 FT (7.6 M) SUCTION LIFT

PUMP DIMENSIONS

PERFORMANCE CURVES

Cornell Pump CompanyP.O. Box 6334 • Portland, Oregon 97228-6334

Web: www.cornellpump.com • Phone (503) 653-0330 • Fax (503) 653-0338

3.47

10.5

10.25

16.12�MIN. CLEAR.

1113.5

5.125.12

124 - .81 DIA.�

HOLES

.62 x .31�KEYWAY

125#�FLANGE

16.36

1

13�MIN. CLEAR.

25.5

3.8811.44

29.81

.88

10.3812.88

2.5

2.5

34.88

125#�FLANGE

NOTES: 1. Frame mounting foot thickness is .75".

2. Flange connection dimension can vary ± .12 inch.

3. Do not use for construction unless certified.