3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32...

8
WWW.VULCRAFT.COM 3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK 3NL-32 Deck Used With Sidelap Screws 3NI-32 Deck Used With TSWs or BPs 3PLN-32 Deck Used With PunchLok ® II System Nominal Dimensions Standard Features Optional Features ASTM A653, A1008, A1063, or A1039 SS GR 50 Min. G60 or G90 Galvanized Gray or White Primer Painted Standard lengths – 6’-0” to 42’-0” UL and FM Listed Tables conform to ANSI/SDI RD-2017. Inquire regarding cost and lead times for: -19 gage -Short cuts < 6’-0” -Alternative metallic and painted finishes PunchLok II System for Sidelap Connection Web Perforated Acoustical Versions Section Properties Deck Gage Deck Weight Base Metal Thickness Yield Strength Effective Moment of Inertia at Service Load I d = (2I e +I g )/3 Effective Section Modulus at F y = 50 ksi Vertical Web Shear w dd t F y I d + I d - S e + S e - V n (psf) (in.) (ksi) (in 4 /ft) (in 4 /ft) (in 3 /ft) (in 3 /ft) (lb/ft) 22 1.8 0.0295 50 0.643 0.715 0.345 0.372 2176 20 2.2 0.0358 50 0.806 0.886 0.448 0.476 3761 19 2.6 0.0418 50 0.965 1.052 0.554 0.579 5127 18 2.9 0.0474 50 1.123 1.200 0.660 0.675 6598 16 3.7 0.0598 50 1.479 1.524 0.869 0.885 9064 Allowable Reactions at Supports Based on Web Crippling, R n /Ω (lb/ft) Bearing Length of Webs Deck Gage End Bearing Interior Bearing 2" 3" 4" 5" 6" ≥ 8" 2" 3" 4" 5" 6" ≥ 8" 22 589 678 753 819 879 890 954 1079 1185 1278 1362 1377 20 848 972 1077 1169 1252 1366 1378 1551 1697 1826 1942 2101 19 1132 1294 1430 1549 1658 1850 1845 2069 2258 2424 2575 2842 18 1432 1631 1799 1947 2081 2318 2338 2614 2847 3051 3237 3565 16 2206 2499 2746 2964 3160 3510 3621 4025 4365 4664 4935 5416 Interlocking Sidelap Nested Sidelap GRADE 50 STEEL 3NL-32 3NI-32 or 3PLN-32 Powerful Partnerships. Powerful Results.

Transcript of 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32...

Page 1: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

WWW.VULCRAFT.COM3Nx-32 GR50 | DECEMBER 2018

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK

• 3NL-32 Deck Used With Sidelap Screws• 3NI-32 Deck Used With TSWs or BPs• 3PLN-32 Deck Used With PunchLok® II System

Nominal Dimensions

Standard Features Optional Features• ASTM A653, A1008, A1063, or A1039 SS GR 50 Min.• G60 or G90 Galvanized• Gray or White Primer Painted• Standard lengths – 6’-0” to 42’-0”• UL and FM Listed• Tables conform to ANSI/SDI RD-2017.

•Inquire regarding cost and lead times for: -19 gage -Short cuts < 6’-0” -Alternative metallic and painted finishes• PunchLok II System for Sidelap Connection• Web Perforated Acoustical Versions

Section Properties

Deck Gage

Deck Weight

Base Metal Thickness

Yield Strength

Effective Moment of Inertiaat Service Load

Id = (2Ie+Ig)/3

Effective Section Modulus at Fy = 50 ksi

Vertical Web

Shear

wdd t Fy Id+ Id- Se+ Se- Vn/Ω

(psf) (in.) (ksi) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (lb/ft)

22 1.8 0.0295 50 0.643 0.715 0.345 0.372 2176

20 2.2 0.0358 50 0.806 0.886 0.448 0.476 3761

19 2.6 0.0418 50 0.965 1.052 0.554 0.579 5127

18 2.9 0.0474 50 1.123 1.200 0.660 0.675 6598

16 3.7 0.0598 50 1.479 1.524 0.869 0.885 9064

Allowable Reactions at Supports Based on Web Crippling, Rn/Ω (lb/ft)Bearing Length of Webs

DeckGage

End Bearing Interior Bearing

2" 3" 4" 5" 6" ≥ 8" 2" 3" 4" 5" 6" ≥ 8"

22 589 678 753 819 879 890 954 1079 1185 1278 1362 1377

20 848 972 1077 1169 1252 1366 1378 1551 1697 1826 1942 2101

19 1132 1294 1430 1549 1658 1850 1845 2069 2258 2424 2575 2842

18 1432 1631 1799 1947 2081 2318 2338 2614 2847 3051 3237 3565

16 2206 2499 2746 2964 3160 3510 3621 4025 4365 4664 4935 5416

Interlocking SidelapNested Sidelap

GRADE 50 STEEL

3NL-32 3NI-32 or 3PLN-32

Powerful Partnerships.Powerful Results.

Page 2: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

ASD, Allowable Uniform Inward Load Table (psf)

Deck Gage Spans Criteria

Span (ft-in.)

6'-0" 7'-0" 8'-0" 9'-0" 10'-0" 11'-0" 12'-0" 13'-0" 14'-0" 15'-0" 16'-0"

22

SingleWn / Ω 191 141 108 85 69 57 48 41 35 31 27

L/240 --- 123 82 58 42 32 24 19 15 12 10

DoubleWn / Ω 194 145 112 89 73 60 51 43 37 33 29

L/240 --- --- --- --- --- --- --- --- --- --- 28

TripleWn / Ω 237 178 138 110 90 75 63 54 47

L/240 --- --- --- 109 80 60 46 36 29

20

SingleWn / Ω 248 183 140 110 89 74 62 53 46 40 35

L/240 245 154 103 72 53 40 31 24 19 16 13

DoubleWn / Ω 255 189 146 116 94 78 65 56 48 42 37

L/240 --- --- --- --- --- --- --- --- --- 41 34

TripleWn / Ω 315 234 181 143 117 97 81 70 60

L/240 --- --- --- 137 100 75 58 45 36

19

SingleWn / Ω 307 226 173 136 111 91 77 65 56 49 43

L/240 293 184 124 87 63 48 37 29 23 19 15

DoubleWn / Ω 313 231 178 141 114 95 80 68 59 51 45

L/240 --- --- --- --- --- --- --- --- --- 49 41

TripleWn / Ω 386 287 221 175 142 118 99 85 73

L/240 --- --- --- 164 119 90 69 54 44

18

SingleWn / Ω 366 269 206 163 132 109 91 78 67 59 51

L/240 341 215 144 101 74 55 43 34 27 22 18

DoubleWn / Ω 366 271 208 165 134 111 93 79 68 60 52

L/240 --- --- --- --- --- --- --- --- --- 56 46

TripleWn / Ω 453 336 258 205 167 138 116 99 85

L/240 --- --- --- 191 139 104 80 63 51

16

SingleWn / Ω 482 354 271 214 173 143 120 103 89 77 68

L/240 449 283 189 133 97 73 56 44 35 29 24

DoubleWn / Ω 481 355 273 216 175 145 122 104 90 78 69

L/240 --- --- --- --- --- --- --- --- 88 71 59

TripleWn / Ω 596 441 339 269 219 181 152 130 112

L/240 --- --- --- 251 183 138 106 83 67

Notes: 1. Table does not account for web crippling. Required bearing should be determined based on specific span conditions. 2. The symbol “---” indicates that the allowable uniform load based on deflection exceeds the allowable load based on stress.

The information in this product data sheet is presented for general information only and is not to be used or relied upon for any application without independent verification by a professional engineer or other qualified professional. Nucor Corporation and its affiliates (collectively, “Nucor”) expressly disclaim (i) any and all representations, warranties and conditions, express or implied, related to the information in this product data sheet, including but not limited to warranties of merchantability, fitness for a particular purpose, and non-infringement; and (ii) any and all liability whatsoever arising out of or related to this product data sheet or its use, including but not limited to liability by reason of death, personal injury or damage to property.

VULCRAFT and PUNCHLOK are registered trademarks of Nucor.

WWW.VULCRAFT.COM

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECKGRADE 50 STEEL

3Nx-32 GR50 | DECEMBER 2018

Powerful Partnerships.Powerful Results.

Page 3: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

WWW.VULCRAFT.COM3Nx-32 GR80 | DECEMBER 2018

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK

• 3NL-32 Deck Used With Sidelap Screws• 3NI-32 Deck Used With TSWs or BPs• 3PLN-32 Deck Used With PunchLok® II System

Nominal Dimensions

Standard Features Optional Features• ASTM A653, A1008, A1063, or A1039 SS GR 80• G60 or G90 Galvanized• Gray or White Primer Painted• Standard lengths – 6’-0” to 42’-0”• UL and FM Listed• Tables conform to ANSI/SDI RD-2017.

•Inquire regarding cost and lead times for: -19 gage -Short cuts < 6’-0” -Alternative metallic and painted finishes• PunchLok II System for Sidelap Connection -Available for galvanized steel only• Web Perforated Acoustical Versions

Section Properties

Deck Gage

Deck Weight

Base Metal Thickness

Yield Strength

Effective Moment of Inertiaat Service Load

Id = (2Ie+Ig)/3

Effective Section Modulus at Fy = 60 ksi

Vertical Web

Shear

wdd t Fy Id+ Id- Se+ Se- Vn/Ω

(psf) (in.) (ksi) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (lb/ft)

22 1.8 0.0295 60 0.635 0.707 0.335 0.346 2176

20 2.2 0.0358 60 0.794 0.876 0.434 0.463 3899

19 2.6 0.0418 60 0.950 1.040 0.536 0.563 5616

18 2.9 0.0474 60 1.103 1.195 0.637 0.659 7227

Allowable Reactions at Supports Based on Web Crippling, Rn/Ω (lb/ft)Bearing Length of Webs

DeckGage

End Bearing Interior Bearing

2" 3" 4" 5" 6" ≥ 8" 2" 3" 4" 5" 6" ≥ 8"

22 707 814 904 983 1055 1068 1145 1295 1422 1533 1634 1653

20 1017 1166 1292 1403 1503 1640 1653 1861 2036 2191 2330 2522

19 1359 1552 1716 1859 1989 2220 2214 2483 2709 2909 3090 3410

18 1718 1957 2159 2336 2497 2782 2806 3137 3416 3662 3884 4279

Interlocking SidelapNested Sidelap

GRADE 80 STEEL

3NL-32 3NI-32 or 3PLN-32

Powerful Partnerships.Powerful Results.

Page 4: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

ASD, Allowable Uniform Inward Load Table (psf)

Deck Gage Spans Criteria

Span (ft-in.)

6'-0" 7'-0" 8'-0" 9'-0" 10'-0" 11'-0" 12'-0" 13'-0" 14'-0" 15'-0" 16'-0"

22

SingleWn / Ω 223 164 125 99 80 66 56 47 41 36 31

L/240 193 121 81 57 42 31 24 19 15 12 10

DoubleWn / Ω 214 160 124 99 81 67 56 48 42 36 32

L/240 --- --- --- --- --- --- --- --- 41 33 27

TripleWn / Ω 260 196 152 122 100 83 70 60 52

L/240 --- --- --- 108 79 59 45 36 29

20

SingleWn / Ω 289 212 162 128 104 86 72 62 53 46 41

L/240 241 152 102 71 52 39 30 24 19 15 13

DoubleWn / Ω 295 219 169 134 109 90 76 65 56 49 43

L/240 --- --- --- --- --- --- --- 63 50 41 34

TripleWn / Ω 363 271 209 167 136 112 95 81 70

L/240 --- --- 192 135 98 74 57 45 36

19

SingleWn / Ω 357 262 201 158 128 106 89 76 66 57 50

L/240 288 182 122 85 62 47 36 28 23 18 15

DoubleWn / Ω 363 269 207 164 133 110 93 79 68 60 52

L/240 --- --- --- --- --- --- --- 75 60 49 40

TripleWn / Ω 448 333 257 204 166 137 116 99 85

L/240 --- --- 230 161 118 88 68 54 43

18

SingleWn / Ω 424 311 238 188 153 126 106 90 78 68 60

L/240 335 211 141 99 72 54 42 33 26 21 18

DoubleWn / Ω 428 316 243 193 156 129 109 93 80 70 61

L/240 --- --- --- --- --- --- --- 86 69 56 46

TripleWn / Ω 529 392 302 240 195 161 136 116 100

L/240 --- --- 267 187 137 103 79 62 50

WWW.VULCRAFT.COM

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECKGRADE 80 STEEL

3Nx-32 GR80 | DECEMBER 2018

Notes: 1. Table does not account for web crippling. Required bearing should be determined based on specific span conditions. 2. The symbol “---” indicates that the allowable uniform load based on deflection exceeds the allowable load based on stress.

The information in this product data sheet is presented for general information only and is not to be used or relied upon for any application without independent verification by a professional engineer or other qualified professional. Nucor Corporation and its affiliates (collectively, “Nucor”) expressly disclaim (i) any and all representations, warranties and conditions, express or implied, related to the information in this product data sheet, including but not limited to warranties of merchantability, fitness for a particular purpose, and non-infringement; and (ii) any and all liability whatsoever arising out of or related to this product data sheet or its use, including but not limited to liability by reason of death, personal injury or damage to property.

VULCRAFT and PUNCHLOK are registered trademarks of Nucor.

Powerful Partnerships.Powerful Results.

Page 5: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

WWW.VULCRAFT.COM3NxA-32 GR50 | DECEMBER 2018

3NLA-32 / 3NIA-32 / 3PLNA-32 ACOUSTICAL ROOF DECK

Nominal Dimensions

Standard Features Optional Features• ASTM A653, A1008, A1063, or A1039 SS GR 50 Min.• G60 or G90 Galvanized• Gray or White Primer Painted• Standard lengths – 6’-0” to 42’-0”• UL and FM Listed• Tables conform to ANSI/SDI RD-2017.

•Inquire regarding cost and lead times for: -19 gage -Short cuts < 6’-0” -Alternative metallic and painted finishes• PunchLok II System for Sidelap Connection

Section Properties

Deck Gage

Deck Weight

Base Metal Thickness

Yield Strength

Effective Moment of Inertiaat Service Load

Id = (2Ie+Ig)/3

Effective Section Modulus at Fy = 50 ksi

Vertical Web

Shear

wdd t Fy Id+ Id- Se+ Se- Vn/Ω

(psf) (in.) (ksi) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (lb/ft)

22 1.7 0.0295 50 0.611 0.680 0.328 0.353 1632

20 2.1 0.0358 50 0.766 0.842 0.424 0.452 2821

19 2.4 0.0418 50 0.917 1.000 0.526 0.550 3846

18 2.8 0.0474 50 1.067 1.140 0.627 0.641 4948

16 3.5 0.0598 50 1.405 1.448 0.826 0.841 6798

Allowable Reactions at Supports Based on Web Crippling, Rn/Ω (lb/ft)Bearing Length of Webs

DeckGage

End Bearing Interior Bearing

2" 3" 4" 5" 6" ≥ 8" 2" 3" 4" 5" 6" ≥ 8"

22 559 643 715 777 834 845 948 1073 1177 1270 1353 1369

20 810 928 1028 1116 1196 1305 1370 1542 1687 1815 1931 2089

19 1086 1241 1371 1486 1590 1775 1835 2058 2246 2411 2561 2827

18 1378 1570 1731 1874 2002 2231 2327 2601 2832 3036 3220 3548

16 2134 2418 2657 2867 3057 3395 3605 4007 4345 4644 4914 5392

Interlocking SidelapNested Sidelap

GRADE 50 STEEL

3NLA-32 3NIA-32 or 3PLNA-32

• 3NLA-32 Deck Used With Sidelap Screws• 3NIA-32 Deck Used With TSWs or BPs• 3PLNA-32 Deck Used With PunchLok® II System

Powerful Partnerships.Powerful Results.

Page 6: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

ASD, Allowable Uniform Inward Load Table (psf)

Deck Gage Spans Criteria

Span (ft-in.)

6'-0" 7'-0" 8'-0" 9'-0" 10'-0" 11'-0" 12'-0" 13'-0" 14'-0" 15'-0" 16'-0"

22

SingleWn / Ω 182 134 102 81 65 54 45 39 33 29 26

L/240 --- 117 78 55 40 30 23 18 15 12 10

DoubleWn / Ω 179 134 104 83 68 57 48 41 35 31 27

L/240 --- --- --- --- --- --- --- --- --- --- 26

TripleWn / Ω 215 163 128 102 84 70 59 51 44

L/240 --- --- --- --- 76 57 44 34 28

20

SingleWn / Ω 236 174 133 105 85 70 59 50 43 38 33

L/240 232 146 98 69 50 38 29 23 18 15 12

DoubleWn / Ω 238 177 137 109 88 73 62 53 46 40 35

L/240 --- --- --- --- --- --- --- --- --- 39 32

TripleWn / Ω 291 218 169 135 110 91 77 66 57

L/240 --- --- --- 130 95 71 55 43 35

19

SingleWn / Ω 292 214 164 130 105 87 73 62 54 47 41

L/240 278 175 117 82 60 45 35 27 22 18 15

DoubleWn / Ω 292 217 167 133 108 90 75 64 56 48 43

L/240 --- --- --- --- --- --- --- --- --- 47 39

TripleWn / Ω 359 268 207 165 134 111 94 80 69

L/240 --- --- --- 156 113 85 66 52 41

18

SingleWn / Ω 348 255 196 155 125 103 87 74 64 56 49

L/240 324 204 137 96 70 53 40 32 25 21 17

DoubleWn / Ω 343 254 196 155 126 105 88 75 65 57 50

L/240 --- --- --- --- --- --- --- --- --- 53 44

TripleWn / Ω 423 315 243 193 157 130 110 94 81

L/240 --- --- --- 181 132 99 76 60 48

16

SingleWn / Ω 458 337 258 204 165 136 115 98 84 73 64

L/240 426 269 180 126 92 69 53 42 34 27 22

DoubleWn / Ω 452 335 258 204 166 137 116 99 85 74 65

L/240 --- --- --- --- --- --- --- --- 83 68 56

TripleWn / Ω 557 414 319 254 206 171 144 123 106

L/240 --- --- --- 239 174 131 101 79 63

WWW.VULCRAFT.COM

3NLA-32 / 3NIA-32 / 3PLNA-32 ACOUSTICAL ROOF DECKGRADE 50 STEEL

3NxA-32 GR50 | DECEMBER 2018

Notes: 1. Table does not account for web crippling. Required bearing should be determined based on specific span conditions. 2. The symbol “---” indicates that the allowable uniform load based on deflection exceeds the allowable load based on stress.

The information in this product data sheet is presented for general information only and is not to be used or relied upon for any application without independent verification by a professional engineer or other qualified professional. Nucor Corporation and its affiliates (collectively, “Nucor”) expressly disclaim (i) any and all representations, warranties and conditions, express or implied, related to the information in this product data sheet, including but not limited to warranties of merchantability, fitness for a particular purpose, and non-infringement; and (ii) any and all liability whatsoever arising out of or related to this product data sheet or its use, including but not limited to liability by reason of death, personal injury or damage to property.

VULCRAFT and PUNCHLOK are registered trademarks of Nucor.

Powerful Partnerships.Powerful Results.

Page 7: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

WWW.VULCRAFT.COM3NxA-32 GR80 | DECEMBER 2018

3NLA-32 / 3NIA-32 / 3PLNA-32 ACOUSTICAL ROOF DECK

Nominal Dimensions

Section Properties

Deck Gage

Deck Weight

Base Metal Thickness

Yield Strength

Effective Moment of Inertiaat Service Load

Id = (2Ie+Ig)/3

Effective Section Modulus at Fy = 60 ksi

Vertical Web

Shear

wdd t Fy Id+ Id- Se+ Se- Vn/Ω

(psf) (in.) (ksi) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (lb/ft)

22 1.7 0.0295 60 0.604 0.672 0.318 0.329 1632

20 2.1 0.0358 60 0.754 0.832 0.412 0.440 2924

19 2.4 0.0418 60 0.903 0.989 0.509 0.535 4213

18 2.8 0.0474 60 1.048 1.136 0.605 0.626 5420

Allowable Reactions at Supports Based on Web Crippling, Rn/Ω (lb/ft)Bearing Length of Webs

DeckGage

End Bearing Interior Bearing

2" 3" 4" 5" 6" ≥ 8" 2" 3" 4" 5" 6" ≥ 8"

22 670 772 857 933 1001 1013 1138 1287 1413 1524 1624 1642

20 972 1114 1234 1339 1435 1566 1644 1850 2024 2178 2317 2507

19 1304 1489 1646 1783 1908 2129 2202 2469 2695 2893 3073 3392

18 1654 1884 2077 2248 2403 2677 2792 3121 3399 3643 3865 4257

Interlocking SidelapNested Sidelap

GRADE 80 STEEL

• 3NLA-32 Deck Used With Sidelap Screws• 3NIA-32 Deck Used With TSWs or BPs• 3PLNA-32 Deck Used With PunchLok® II System

Standard Features Optional Features• ASTM A653, A1008, A1063, or A1039 SS GR 80• G60 or G90 Galvanized• Gray or White Primer Painted• Standard lengths – 6’-0” to 42’-0”• UL and FM Listed• Tables conform to ANSI/SDI RD-2017.

•Inquire regarding cost and lead times for: -19 gage -Short cuts < 6’-0” -Alternative metallic and painted finishes• PunchLok II System for Sidelap Connection -Available for galvanized steel only

Powerful Partnerships.Powerful Results.

3NLA-32 3NIA-32 or 3PLNA-32

Page 8: 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 … Roof...3Nx-32 GR50 | DECEMBER 2018 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK • 3NL-32 Deck Used With Sidelap Screws • 3NI-32 Deck Used

ASD, Allowable Uniform Inward Load Table (psf)

Deck Gage Spans Criteria

Span (ft-in.)

6'-0" 7'-0" 8'-0" 9'-0" 10'-0" 11'-0" 12'-0" 13'-0" 14'-0" 15'-0" 16'-0"

22

SingleWn / Ω 212 155 119 94 76 63 53 45 39 34 30

L/240 183 115 77 54 40 30 23 18 14 12 10

DoubleWn / Ω 196 148 115 92 75 63 53 45 39 34 30

L/240 --- --- --- --- --- --- --- --- 39 31 26

TripleWn / Ω 234 179 140 113 93 77 65 56 49

L/240 --- --- --- 103 75 56 43 34 27

20

SingleWn / Ω 274 201 154 122 99 82 69 58 50 44 39

L/240 229 144 97 68 49 37 29 22 18 15 12

DoubleWn / Ω 274 205 159 126 103 85 72 61 53 46 41

L/240 --- --- --- --- --- --- --- 60 48 39 32

TripleWn / Ω 334 251 195 156 127 106 89 76 66

L/240 --- --- 182 128 93 70 54 42 34

19

SingleWn / Ω 339 249 190 151 122 101 85 72 62 54 48

L/240 274 173 116 81 59 44 34 27 22 18 14

DoubleWn / Ω 339 252 195 155 126 104 88 75 65 57 50

L/240 --- --- --- --- --- --- --- 71 57 46 38

TripleWn / Ω 416 311 241 192 156 130 109 93 81

L/240 --- --- 218 153 112 84 65 51 41

18

SingleWn / Ω 403 296 226 179 145 120 101 86 74 64 57

L/240 318 200 134 94 69 52 40 31 25 20 17

DoubleWn / Ω 400 297 229 182 148 122 103 88 76 66 58

L/240 --- --- --- --- --- --- --- 82 65 53 44

TripleWn / Ω 492 367 283 225 184 152 128 110 95

L/240 --- --- 253 178 130 97 75 59 47

WWW.VULCRAFT.COM

3NLA-32 / 3NIA-32 / 3PLNA-32 ACOUSTICAL ROOF DECKGRADE 80 STEEL

3NxA-32 GR80 | DECEMBER 2018

Notes: 1. Table does not account for web crippling. Required bearing should be determined based on specific span conditions. 2. The symbol “---” indicates that the allowable uniform load based on deflection exceeds the allowable load based on stress.

The information in this product data sheet is presented for general information only and is not to be used or relied upon for any application without independent verification by a professional engineer or other qualified professional. Nucor Corporation and its affiliates (collectively, “Nucor”) expressly disclaim (i) any and all representations, warranties and conditions, express or implied, related to the information in this product data sheet, including but not limited to warranties of merchantability, fitness for a particular purpose, and non-infringement; and (ii) any and all liability whatsoever arising out of or related to this product data sheet or its use, including but not limited to liability by reason of death, personal injury or damage to property.

VULCRAFT and PUNCHLOK are registered trademarks of Nucor.

Powerful Partnerships.Powerful Results.