320 Validate CoS Reading 320 Message Specific Information Message Header 320 MPRN Level Information Message Usage Factors 320 OptM Register Level Info ReqM 320 Meter ID ReqM

Transcript of 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading....

Page 1: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading

320Message Specific

Information

Message Header

320 MPRN Level Information

Message

Usage Factors 320

OptM

Register Level Info

ReqM

320 Meter ID

ReqM

Page 2: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading

Message Specific informationMessage

320 Valid CodesMeter Point StatusE – EnergisedRead Reason26 – Change of SupplierRead TypeA – An actual reading obtained by ESB NetworksE – An estimate due to no-access or a missing register readingEF – An estimate due to an implausible reading / No read availableRC – A replacement reading or estimate agreed for use by both SuppliersCU – A reading provided directly by a customerSC – A customer reading provided by a SupplierEP – An estimate due to a planned no-visitEU – An estimate due to an unplanned no-visitPlease NoteEstimate of ConsumptionThis is provided for all non MD registers and only at CoS and to the New Supplier only. This value will not necessarily be equal to the EUF for the timeslot.

Optional/Mandatory; Although the following Data Items are optional, note the following caveats:- Estimated Usage Factor: Provided for the period following the read date

Page 3: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

Message Header Message Type

Req

Version Number

Req

Transaction Reference

NumberReq

Timestamp

Req

Recipient ID

Req

Senders ID

Req

Message HeaderMessage

Name Message Type Description This is the Market Message Number. Schema Name MessageTypeCode Length Maximum (Variable) 4 Length Minimum (Variable) 3 Pattern [0-9]{3}[A-Z]{0,1} Type Data Item
Name Version Number Description Version Number of the current retail market Message Schema. Schema Name VersionNumber Length 8 Pattern ([0-9]{2}\.[0-9]{2}\.[0-9]{2}) Data Type string Type Data Item
Name Transaction Reference Number Description Header Information Schema Name TxRefNbr Length Maximum (Variable) 35 Pattern [A-Za-z0-9 ,.;:/\[+\-_=\]]{1,} Data Type string Type Data Item
Name Timestamp Description The date/time that the message was encrypted. Schema Name MarketTimestamp Data Type dateTime Type Data Item
Name Recipient ID Description Party ID of the recipient of the message. Schema Name RecipientID Length 3 Data Type string Type Data Item
Name Senders ID Description Party ID of the sender of the message. Schema Name SenderID Length 3 Data Type string Type Data Item
Page 4: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

320 MPRN Level Info

Meter Point Status

Req

MPRN

Req

Networks Reference

NumberReq

Load Profile

Req

Read Date

Req

DUoS Group

Req

320 MPRN Level InformationMessage

Market Participant Business

ReferenceOpt

Meter Configuration

CodeReq

Name Meter Point Status Description A code to identify the requested connection status of a meter point. Schema Name MeterPointStatusCode Length Maximum (Variable) 2 Data Type string Type Data Item
Name MPRN Description The unique identifying reference for the Meter Point. Schema Name MPRN Length 11 Data Type string Type Data Item
Name Networks Reference Number Description A Non-Interval billing document reference created at inception of the Non-Interval billing document and used to reference that Non-Interval billing transaction. Schema Name NetworksReferenceNumber Length Maximum (Variable) 35 Data Type string Type Data Item
Name Load Profile Description Load Profile is a code that determines, when coupled with Timeslot, the derived profile to be applied to the consumption for settlement. Schema Name LoadProfileCode Length Maximum (Variable) 3 Data Type string Type Data Item
Name Read Date Description Read Date is the date on which a reading was physically obtained from the meter, or was estimated in the case where a reading was not obtained. Schema Name ReadDate Data Type date Type Data Item
Name DUoS Group Description DUoS Group is a code which denotes the distribution use of system tariff applying to the MPRN. Schema Name DUOS_Group Length Maximum (Variable) 4 Data Type string Type Data Item
Name Market Participant Business Reference Description This is the Suppliers number given as reference in the request. Schema Name MPBusinessReference Length Maximum (Variable) 35 Data Type string Type Data Item
Name Meter Configuration Code Description Meter Configuration Code is a code to indicate the functionality present in a meter at a site as required by the Supplier to be delivered by the combination of registers physically installed at a meter point. It does not describe the technical attributes of the meter(s). Schema Name MeterConfigurationCode Length Maximum (Variable) 10 Data Type string Type Data Item
Page 5: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

Usage Factors 320

Timeslot

Req

Usage Factors 320Message

Effective from Date

Req

Estimated Usage Factor

Opt

Name Timeslot Description Timeslot is a code that indicates the period that a meter is recording (or an unmetered installation is consuming electricity). Schema Name TimeslotCode Length Maximum (Variable) 10 Data Type string Type Data Item
Name Effective From Date Description Effective From Date is a date that indicates the inclusive date from which a notified event, such as a meter installation, change or removal, a change of supplier, customer details or metering characteristics, or an EUF, is effective. Schema Name EffectiveFromDate Data Type date Type Data Item
Name Estimated Usage Factor Description Estimated Usage Factor is a statement in kWh of the estimated consumption for a given Timeslot at a Meter Point over the next year Schema Name EstimatedUsageFactor Digits (Total) 15 Digits (Post-Decimal) 8 Data Type decimal Type Data Item
Page 6: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

320 Meter ID Meter Category

Opt

Serial Number

Req

320 Meter ID Message

Meter Location

Opt

Name Meter Category Description Meter Category is a code allocated by Meter Asset Manager to denote the manufacturer and type of meter. Schema Name MeterCategoryCode Length Maximum (Variable) 15 Data Type string Type Data Item
Name Serial Number Description Serial No is the physical number found on a meter. Schema Name SerialNumber Length Maximum (Variable) 9 Data Type string Type Data Item
Name Meter Location Description Meter Location is a code that refers to the physical position of a meter at a premises. Schema Name MeterLocationCode Length Maximum (Variable) 3 Data Type string Type Data Item
Page 7: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

Meter Register Sequence

Req

Timeslot

Reading

Register Type

Req

Register Level Information

Register Level InformationMessage

Req

Req

Unit of Measurement

Req

Meter Multiplier

Req

Read Reason

Req

Read Type

Req

Previous Read Date

Req

Consumption

Opt

Read Status

Req

Name Meter Register Sequence Description Meter Register Sequence is the identifier of a specific register to distinguish between registers dials on a physical meter or set of meters. Schema Name MeterRegisterSequence Length Maximum (Variable) 3 Data Type string Type Data Item
Name Timeslot Description Timeslot is a code that indicates the period that a meter is recording (or an unmetered installation is consuming electricity). Schema Name TimeslotCode Length Maximum (Variable) 10 Data Type string Type Data Item
Name Reading Description Reading is the value of a reading in the form passed to the Data Processor measured in the units identified by the meter register prior to application of any multipliers. Schema Name ReadingValue Digits (Total) 15 Digits (Post-Decimal) 3 Data Type decimal Type Data Item
Name Register Type Description Register Type is a code that indicates the purpose of the register. Schema Name RegisterTypeCode Length 2 Data Type string Type Data Item
Name Unit of Measurement Description Unit of measurement is the code that indicates the value that is measured (e.g. kWh, kVA, kVAr). Schema Name UOM_Code Length Maximum (Variable) 3 Data Type string Type Data Item
Name Meter Multiplier Description Meter Multiplier is a factor to be applied to an advance or reading at a register in order to derive a value in kWh. Schema Name MeterMultiplier Digits (Total) 12 Digits (Post-Decimal) 5 Data Type decimal Type Data Item
Name Read Reason Description Read Reason is a code that indicates the reason that a reading was collected (e.g. Starting, Closing, Energisation, De-Energisation, Set Active, Set In-Active, Schedule, Special, Verification and Change of Supplier). Schema Name ReadReasonCode Length Maximum (Variable) 2 Data Type string Type Data Item
Name Read Type Description Read Type is a code that indicates whether a reading is an Actual, Customer, Estimated or Substitute reading. Schema Name ReadTypeCode Length Maximum (Variable) 2 Data Type string Type Data Item
Name Previous Read Date Description Previous Read Date is the date to which the most recent reading or estimate prior to the one currently being reported applies, i.e. this is the end of the of the previous consumption period for the register Schema Name PreviousReadDate Data Type date Type Data Item
Name Consumption Description Consumption is the metered or estimated consumption for the period from a previous read date to this read date, measured in kWh. Schema Name Consumption Digits (Total) 15 Digits (Post-Decimal) 3 Data Type decimal Type Data Item
Name Read Status Description Read Status is a code that indicates whether a reading is Accepted, Rejected, Valid, Invalid or Withdrawn. Schema Name ReadStatusCode Length Maximum (Variable) 4 Data Type string Type Data Item
Page 8: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Senders ID

Senders ID

Click Here for Latest Senders ID

List

Message Message Header

Page 9: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Load ProfileMessage MPRN LevelInformation

Load Profile01 – Urban Domestic

Unrestricted

02 – Urban Domestic Day/Night

03 – Rural Domestic Unrestricted

04 – Rural Domestic Day/Night

05 – Non Domestic Unrestricted

06 – Non Domestic Day/Night

07 – MD with LF up to(but not including)

30%

08 – MD with LF greater than or equal to 30% but

less than 50%

09 – MD with LF greater than or equal

to 50%

10 – Unmetered - Flat

11 – Public Lighting Dusk/Dawn

12 – Public Lighting Dusk/Midnight

Page 10: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

DUoS GroupMessage MPRN LevelInformation

DUoS GroupAGU DG1 Urban Domestic DG7 MV MDAMM DG10 Yes DG7A MV MD AutoproducerCAN DG2 Rural Domestic DG7B MV MD Importing Autoproducer or CHP

ProducerCIP DG3 Public Lighting DG8 38 kV Looped MDCOL DG4 Unmetered Supplies DG8A 38 kV Looped MD AutoproducerCOS DG5 LV Non-Domestic Non-MD DG8B 38 kV Looped MD Importing Autoproducer or

CHP ProducerCUG DG5A LV Non-Domestic Non-MD Autoproducer DG9 38 kV Tailed MD

DIJ DG5B LV Non-Domestic Non-MD Importing Autoproducer or CHP Producer

DG9A 38 kV Tailed MD Autoproducer

DSO DG6 LV MD DG9B 38 kV Tailed MD Importing Autoproducer or CHP Producer

IA DG6A LV MD Autoproducer DG10 110kV DistributionICD DG6B LV MD Importing Autoproducer or CHP

ProducerTCON Transmission Connected

Page 11: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Meter Point StatusMessage MPRN LevelInformation

Meter Point Status

A – Assigned

C - Created

D – De-Energised

E - Energised

T- Terminated

Page 12: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

Message MPRN LevelInformation Meter Configuration Code

Meter Configuration

CodeMCC01 – 24 Hour

MCC02 – P/N

MCC03 – 24h+NSH

MCC04 – D/N+W

MCC05 – MDNm/PK

MCC06 – MDNm+Pk

MCC07 –24H+NSH+W

MCC08 – 24h+W

MCC09 - Unmetered

MCC10 – QH2CH_IP

MCC11 –QH4CH_IPXP

MCC50 - NONSTN

MCC51 – D/N+NSH

MCC53 – 2 X D/N

MCC57 – 24h+D

MCC58 – 24h+D/N

MCC59 – 24h+D/N+W

MCC60 – 24h+D/N+NS

MCC61 – 2x24h

MCC62 –2x24h+NSH

MCC63 – 2x24h+D

MCC64 – 2x24h+W

MCC65 – 3x24hr

MCC67 – 3x24h+Day

MCC70 –3x24H+NSH

MCC71 – 4x24H

MCC72 – 3x24H+W

MCC73 –4x24H+NSH

MCC74 – 5x24H

MCC75 –24H+2xNSH

MCC76 – 4x24H+W

MCC77 –2x24H+W+NSH

MCC78 –3x24H+W+NSH

MCC79 –5x24H+NSH

Page 13: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Timeslot00D – 08- 23 Day

Consumption

00N – 23-08 Night Consumption

ONR – 08-21 MD Normal

OPK – 17-19 MD Peak

24H – 24 Hour Consumption

24M – 24 Hour MD

TimeslotMessage Usage Factors 320 Register Level Info

Page 14: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Meter Category

Meter CategoryMessage Meter ID 320

RM001 Single Tariff kWh RM228 Double Tarif f kWh RM511 Single Tarif f kWh RM621 C.T. Double Tarif f kWh RM752 M.F.M.RM002 Single Tariff kWh RM229 Double Tarif f kWh RM512 Single Tarif f kWh RM622 C.T. Double Tarif f kWh RM753 Double Tarif f Mechanical MD RM003 Single Tariff kWh RM230 Double Tarif f kWh RM513 Single Tarif f kWh RM623 C.T. Double Tarif f kWh RM754 M.F.M.RM004 Single Tariff kWh RM231 Double Tarif f kWh RM514 Single Tarif f kWh RM624 C.T. Double Tarif f kWh RM755 M.F.M.RM005 Single Tariff kWh RM232 Double Tarif f kWh 2 Element RM515 Single Tarif f kWh RM625 C.T. Double Tarif f kWh RM756 M.F.M.RM006 Single Tariff kWh RM233 Double Tarif f kWh 2 Element RM516 3-Phase Mechanical Single Tarif f Meter RM626 C.T. Double Tarif f kWh RM757 M.F.M.RM007 Single Tariff kWh RM234 Double Tarif f kWh RM520 Double Tarif f kWh RM627 Electronic Double Tarif f kWh RM758 M.F.M.RM008 Single Tariff kWh RM235 Double Tarif f kWh RM521 Double Tarif f kWh RM640 C.T. Single Tariff Mech anical MD RM759 M.F.M.RM010 Single Tariff kWh RM250 Electronic Double Tarif f kWh RM522 Double Tarif f kWh RM641 C.T. Single Tariff Mech anical MD RM760 M.F.M.RM011 Single Tariff kWh RM251 Double Tarif f kWh 2 Element RM523 Double Tarif f kWh RM645 M.F.M. RM761 M.F.M.RM020 Single Tariff kWh RM252 Electronic Double Tarif f kWh RM524 Double Tarif f kWh RM646 M.F.M. RM762 M.F.M.RM021 Single Tariff kWh RM253 Electronic Double Tarif f kWh (AMPY 5224E) RM525 Double Tarif f kWh RM647 M.F.M. RM763 M.F.M.RM022 Single Tariff kWh RM255 Electronic Multi rate kWh RM526 Double Tarif f kWh RM648 M.F.M. RM764 M.F.M.RM030 Single Tariff kWh RM256 Electronic Multi rate kWh RM527 Double Tarif f kWh RM649 M.F.M. RM765 M.F.M.RM031 Single Tariff kWh RM257 Electronic Multi Rate kWh RM528 Double Tarif f kWh RM650 M.F.M. RM766 M.F.M.RM032 Single Tariff kWh RM258 Electronic Multi Rate kWh RM529 Double Tarif f kWh RM651 M.F.M. RM767 M.F.M.RM033 Single Tariff kWh RM259 Electronic Multi Rate kWh RM530 Double Tarif f kWh RM652 M.F.M. RM768 M.F.M.RM034 Single Tariff kWh RM280 Hardw ired RM531 Double Tarif f kWh RM660 C.T. Double Tarif f Mechanical MD RM769 M.F.M.RM035 Single Tariff kWh RM281 DLC RM532 Double Tarif f kWh RM661 C.T. Double Tarif f Mechanical MD RM770 Single Tarif f kVArhRM036 Single Tariff kWh RM300 Smart GPRS 3Ph WC 1-20(100) RM533 Double Tarif f kWh RM662 C.T. Double Tarif f Mechanical MD RM771 Single Tarif f kVArhRM039 Single Tariff kWh RM301 Smart DLC 3PH WC 0.25-5(80)A RM534 RM534 - Electronic Double Tarif f kWh RM663 C.T. Double Tarif f Mechanical MD RM772 Single Tarif f kVArhRM040 Single Tariff kWh RM302 Smart RF 3PH WC 0.5-10(100)A RM540 Mechanical MD RM664 C.T. Double Tarif f Mechanical MD RM773 Single Tarif f kVArhRM041 Single Tariff kWh RM303 Smart RF 3PH WC 1-20(100)A RM541 Mechanical MD RM665 C.T. Double Tarif f Mechanical MD RM774 Single Tarif f kVArhRM042 Single Tariff kWh RM304 Smart PLC 3PH WC 1-20(100)A RM542 Mechanical MD RM666 C.T. Double Tarif f Mechanical MD RM775 Single Tarif f kVArhRM043 Single Tariff kWh RM350 Smart GPRS 3Ph WC 1-20(100) RM543 Mechanical MD RM667 M.F.M. RM776 Single Tarif f kVArhRM050 Electronic Single Tariff kWh RM351 Smart DLC 3PH CT 0.25-5(80)A RM545 M.F.M. RM670 C.T. kVArh RM777 Single Tarif f kVArhRM051 Single Tariff kWh Budget Controller RM352 Smart RF 3PH CT 0.5-10(100)A RM546 M.F.M. RM671 C.T. kVArh RM780 SummatorRM052 Single Tariff kWh Budget Controller RM353 Smart RF 3PH CT 1-20(100)A RM547 M.F.M. RM672 C.T. kVArh RM781 M.F.M. (PWRM/PML Ion 7600)RM054 Single Tariff kWh Budget Controller RM354 Smart PLC 3PH CT 1-20(100)A RM548 M.F.M. RM673 C.T. kVArh RM782 M.F.M. (PWRM/PML Ion 7650)RM055 Single Tariff kWh Budget Controller RM400 Single Tarif f Current Transformer kWh RM549 M.F.M. RM674 C.T. kVArh RM783 M.F.M. (PWRM/PML Ion 7650)RM056 Single Tariff kWh Budget Controller RM401 Single Tarif f Current Transformer kWh RM550 M.F.M. (Elster A1140) RM675 C.T. kVArh RM784 Summator (PSI Siemens Maxsys V2737/R33)RM066 Electronic Single Tariff kWh RM402 Single Tarif f Current Transformer kWh RM551 M.F.M. RM676 C.T. kVArh RM785 M.F.MRM067 Electronic Single Tariff kWh RM403 Single Tarif f Current Transformer kWh RM552 M.F.M. RM720 Double Tarif f kWh RMAB1 Single Phase Single Tarif f kWhRM068 Electronic Single Tariff kWh RM420 Double Tarif f Current Transformer kWh RM553 M.F.M. RM721 Double Tarif f kWh RMAB3 Single Tarif f kWhRM100 Smart GPRS 1PH WC 1-20(100)A RM421 Double Tarif f Current Transformer kWh RM570 Single Tarif f kVArh RM722 Double Tarif f kWh RMB10 Single Phase Single Tarif f kWhRM101 Smart DLC 1PH WC 0.25-5(80)A RM422 Double Tarif f Current Transformer kWh RM571 Single Tarif f kVArh RM723 Double Tarif f kWh RMB14 Single Phase Single Tarif f kWhRM102 Smart RF 1PH WC 0.5-10(100)A RM423 Double Tarif f Current Transformer kWh RM572 Single Tarif f kVArh RM740 Single Tariff Mechanical MD RMB15 Single Tarif f kWhRM103 Smart RF 1PH WC 1-20(100)A RM424 Double Tarif f Current Transformer kWh RM573 Single Tarif f kVArh RM741 Single Tariff Mechanical MD RMB16 Single Phase Single Tarif f kWhRM104 Smart RF 1PH WC 1-20(100)A RM425 Double Tarif f Current Transformer kWh RM574 Single Tarif f kVArh RM742 Single Tariff Mechanical MD RMB20 Single Phase Single Tarif f kWhRM105 Smart PLC 1PH WC 1-20(100)A RM426 Double Tarif f Current Transformer kWh RM575 Single Tarif f kVArh RM743 Double Tarif f Mechanical MD RMB34 Single Tarif f kWhRM220 Double Tarif f kWh RM500 Single Tarif f kWh RM576 Single Tarif f kVArh RM744 Double Tarif f Mechanical MD RMB36 Single Tarif f kWhRM221 Double Tarif f kWh RM501 Single Tarif f kWh RM600 C.T. Single Tariff kWh RM745 Double Tarif f Mechanical MD RMB40 Single Phase Single Tarif f kWhRM222 Double Tarif f kWh RM502 Single Tarif f kWh RM601 C.T. Single Tariff kWh RM746 Double Tarif f Mechanical MD RMB45 Single Phase Single Tarif f kWhRM223 Double Tarif f kWh RM503 Single Tarif f kWh RM602 C.T. Single Tariff kWh RM747 Double Tarif f Mechanical MD RMB60 Single Phase Single Tarif f kWhRM224 Double Tarif f kWh RM504 Single Tarif f kWh RM603 C.T. Single Tariff kWh RM748 Double Tarif f Mechanical MD RMB63 Single Tarif f kWhRM225 Double Tarif f kWh RM505 Single Tarif f kWh RM604 C.T. Single Tariff kWh RM749 Double Tarif f Mechanical MD RMB80 Single Phase Single Tarif f kWhRM226 Double Tarif f kWh RM506 Single Tarif f kWh RM617 C.T. kVArh RM750 Double Tarif f Mechanical MD RMDT1 Double Tarif f kWhRM227 Double Tarif f kWh RM510 Single Tarif f kWh RM620 C.T. Double Tarif f kWh RM751 Double Tarif f Mechanical MD RMDT3 Double Tarif f kWh

TKMTR Single Phase Single Tarif f kWh

Page 15: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Segment

Message Meter ID 320 Meter Location

Meter Location 01 - Basement

02 - Garage

03 - Hall

04 - Kitchen

05 - Landing

06 - Office

07 – Outside box

08 - Porch

09 - Press

10 - Pumphouse

11 – Scullery/Pantry/Kitchen

12 - Shop

13 – Switchroom/Board

14 – Under Stairs

15 – Car Park

16 - Pole

17 - Lobby

18 – Shed/Outoffice/Barn

19 - Annexe

20 – Milking parlour/Dairy

21 - Workshop

22 - Store

23 – Back door

24 - Bedroom

25 – Boiler House

26 - Factory

Page 16: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Unit of MeasurementMessage Register Level Info

Unit of Measurement

K3 - kVArh

KVA - kVA

KVR - kVAr

KWH - kWh

KWT - kW

MWH - Mwh

Page 17: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Read ReasonMessage Register Level InfoMessage

Read Reason 01 - Scheduled

02 – Special Read, Chargeable

04 – Special Read to resolve dispute

09 – Special Read, non chargeable

10 – Ad-hoc, no chargeable check

read

11 – Start reading after meter re-programming

13 – De-Energisation

14 - Estimate

16 – Closing read before meter re-

programming

17 – Change of Profile

18 - Energisation

21 – Start Reading ( New Register)

22 – Closing Reading (Register removed)

23 – Meter Works Single reading

26 – Change of Supplier

27 – Change of Legal Entity

28 – Closing read before register re-

number

29 – Star read after register re-number

95 – Not for CoS

Page 18: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Read Type A - Actual

CU – Customer Reading

E – Estimate (No Access)

ED – Estimate (DUoS Billing has occurred)

EF – Estimate (Implausible/No Read available)

EP – Estimate (Block Planned)

EU – Estimate (Block Unplanned)

RC – Replacement Read

SC – Supplier Provided Customer

Reading

SU – Substitute (Interval)

Read TypeMessage Register Level Info

Page 19: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Register Type 01 – 24hr

02- Day

03 - Night

04 - NSH

05 - Wattless

06 – MD Normal

07 – MD Peak

08 – Cumulative MD Normal

09 – Cumulative MD Peak

50 – IMP QH (KW)

51 – IMP QH (kVAr)

52 – EXP QH(KW)

53 – EXP QH (kVAr)

Register TypeMessage Register Level Info

Page 20: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading Code

Message Register Level Info Read Status

Read StatusRENS – Reading

estimated – Not used for settlement

REST – Reading estimated – used for

settlement

RREL – Reading –Manually released

RV – Reading Valid

RWI – Reading Withdrawn

Page 21: 320 Validate CoS Reading Message - rmdsie.files.wordpress.com€¦ · 320 Validate CoS Reading. Segment. Usage Factors 320 Timeslot. Req. Message. Usage Factors 320. Effective from

320 Validate CoS Reading

Version Which Implemented Description of ChangeSource of Change

10.4 MCR 1155 Message format changed from ARIS to Document format.

Message History of Changes