N E T W O R K S U P E R V I S I O N [email protected] Gli standard per la categoria 6 e i nuovi strumenti di misura "IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

Transcript of 3 standard per la cat 6 e i nuovi strumenti di mi sura...

Page 1: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

[email protected]

Gli standard per la categoria 6 e i nuovi strumenti di misura

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LACERTIFICA SUL CAMPO DEI PARAMETRI

TRASMISSIVI FINO A 250 MHZ"

Page 2: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What is Fluke Networks, Inc. today?

• A stand-alone company set apart fromFluke Corporation in May, 2000, to createan even more tightly aligned, customer-needs driven organization

• ~ $200M in annual revenues• Over 500 associates worldwide• Combines the best of Fluke’s heritage for

quality and reliability with network know-how and a strong entrepreneurial spirit

Page 3: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What we provide

HouseHouse

House

House

House

Internet /TelephonyNetwork

Servers

SharedWorkgroup

Router

RemoteOffice

Router

SwitchedWorkgroup

OSP/TelecomEnterprise Networks

Copper and Fiber Structured Cabling

OSP/Telecom:Local Loop Recovery

Documentation &Reporting

DSL QualificationTroubleshooting

Enterprise Networks:Performance Analysis

Monitoring & TroubleshootingReporting & Documentation

Moves, Adds, & Changes

Copper & FiberStructured Cabling:

CertificationDocumentation &

ReportingInspection

Troubleshooting

Page 4: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

•48 Countries

•220 Sales Professionals

•1800 Distribution Outlets

•50% of our sales come from outside the US

•75% of 2001 revenue was generated by newproducts introduced in 2000 and 2001

•Profitable and Growing

Page 5: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What Does Fluke Networks Do?

We deliver

What is that supposed to mean?

Page 6: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

We offer more ways to look at your network:

Hardware Software

Physical Application

LAN WAN

Portable Distributed

Page 7: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

http://www.flukenetworks.com

Page 8: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

http://www.fluke-net.com/consultants

Page 9: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

568-A Has Changed to 568-B

ANSI/TIA/EIA568-A-1995

568-A

ANSI/TIA/EIA 568-B-2001

=B.1 General Reqmts

B.2 Copper

B.3 Fiber

568-B.1

=568-B.3

568-B.2

Page 10: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What’s going away?• TIA/EIA TSB67• TIA/EIA TSB72• TIA/EIA TSB75• TIA/EIA TSB95• ANSI/TIA/EIA568A1• ANSI/TIA/EIA568A2• ANSI/TIA/EIA568A3• ANSI/TIA/EIA568A4• ANSI/TIA/EIA568A5• TIA/EIA/IS729

B.1 General Reqmts

B.2 Copper

B.3 Fiber

568-B.1

568-B.3

568-B.2

Page 11: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

TIA adopts the “Permanent Link”

TIA harmonizes with ISOThe revised TIA standards

no longer specify Basic Link

Page 12: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

USER’SPATCHCORD

PATCHPANEL

HORIZONTAL CABLE

TelecomOutlet

USER’SPATCHCORD

FLOOR DISTRIBUTORFLOOR DISTRIBUTORWORKWORKAREAAREA

ChannelEnd

ChannelEnd

Two transitions at each end

CP

Link Definition: “Channel”

CP: Consolidation Point

Page 13: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

WORK AREAWORK AREA

Link End

HORIZONTAL CABLE

TelecomOutlet

TESTERPATCHCORD

Link End

TESTERPATCHCORD

PATCHPANEL

FLOOR DISTRIBUTORFLOOR DISTRIBUTOR

One transition at each endTester patch cables max. 2 m long

Link Definition: “Basic Link”

Page 14: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

We used to test the Basic Link

The Basic Link starts and ends at thetester itself, and it includes the adaptercords

Telecommunication Room Work Area

Patch Panel Outlet90 meter max

Includes TesterAdapter Cords

Basic Link

Page 15: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Telecommunication Room Work Area

Patch Panel Outlet90 meter max

Includes TesterAdapter Cords

Basic Link

But the Basic Link is obsolete

Per TIA/EIA-568-B, the Permanent Linkmodel replaces the Basic Link model

Page 16: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Basic Link Weaknesses• Developing new Cat 5e specifications

revealed some new challenges– Return Loss became a critical parameter that

had not been considered before– Stranded UTP used in patch cables (and cable

tester cords) was found to be very unstable andmajor cause of poor Return Loss performance.

– The Basic Link definition included 4 meters ofcable tester cords in the performance limits,test methods, and test results!

Page 17: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Link End

TESTERPATCHCORD

TelecomOutlet

TESTERPATCHCORD

WORK AREAWORK AREA

PatchPanel

HORIZONTAL CABLE

FLOOR DISTRIBUTORFLOOR DISTRIBUTOR

Test results do not includecontributions by the tester patch

cablesLink End

CP

Link Definition: “Permanent Link”

CP: Consolidation Point

Page 18: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What is a “permanent link”?

• The fixed cabling in the walls – the“permanent” part of the buildinginfrastructure

• The link model to be used for testingthe “fixed” portion of a cablinginstallation

• This excludes users’ patch cables andequipment cords

• This excludes tester adapter cords, too

Page 19: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

A detailed look at the Permanent LinkThe Permanent Link is the permanentcabling, and it does not include theadapter cords

Permanent Link

Consolidation Point (optional)

Does NOT includeTester Adapter Cords

Telecommunication Room Work Area

PatchPanel

Outlet

Page 20: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

The purpose of field test• Accurately characterize the fixed portion of the data

cabling installation upon completion of theinstallation

• Network equipment, patch cables and equipmentcables are changed many times during the life spanof the fixed portion of the cabling (the infrastructure)

• Provide guarantee that the ‘Channel’ meets thenetwork’s requirements by connecting good patchcords

Page 21: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Cat 5e and Cat 6 test problems

Measured CalculatedWire mapPropagation delay Length, Delay SkewAttenuationNEXT (pair-to-pair) PSNEXT, ACR, PSACRFEXT (pair-to-pair) ELFEXT, PSELFEXTReturn Loss

There are two measured parameters thatpresent serious accuracy problems that arevery difficult for testers to correct

Page 22: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Return Loss is a major challenge

Permanent Link

Measured separately from both ends, ReturnLoss is a measure of reflected signal(undesirable)

The Return Loss that should be measured, which isattenuated by the link, is within the link:

(Reflections occur wherever there arechanges in impedance, such as bends, twist

variations, terminations, connectors, etc.)

Page 23: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Return Loss is a major challenge

Permanent Link

Measured separately from both ends, ReturnLoss is a measure of reflected signal(undesirable)

The Return Loss that should be measured, which isattenuated by the link, is within the link:

But Return Loss in the tester’s adapter cords addsmeasurement error and must be eliminated – and there is only one solution – the DSP-LIA101S!

Page 24: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

The impact of twisted-pair adapters

• Twisted-pair adapters degrade withhandling and use in the field – ReturnLoss margin can drop significantly

• Permanent links that are good – but closeto the limit – can produce false failures

• Permanent links that are very good canstill yield poor test results – becausetwisted-pair tester adapters contribute toReturn Loss!

Use the DSP-LIA101S to PASS!

Page 25: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Return Loss of twisted-pair adapter

0

5

10

15

20

25

30

35

40

45

50

0 50 100 150 200 250 300 350 400

CAT6 BLBL +12dBInitial50 cyc100 cyc200 cycCable Lim

21-7*LOG(f/20)

26-12*LOG(f/100)

Basic Link

BL + 12 dB

Impact of handling and “aging”- Sample 1

Frequency (MHz)

Ret

urn

Loss

(dB

)

Page 26: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Correction for adapter cableTest parameter Effect of tester patch cable

Attenuation Stable – Corrected

LengthPropagation delay

Stable – Corrected

NEXT & FEXT High Quality patch cord(PiMF or SSTP) hasnegligible crosstalk

Return Loss Unpredictablllle !!

Page 27: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Requirements for accurate Return Loss

The tester’s permanent link interface cableitself must have very good return losscharacteristics1. Impedance very close to 100 ΩΩΩΩ2. Very good Return Loss performance3. Stability: very stable impedancecharacteristic over time (after repeateduncoiling, testing, and recoiling to packwith tester)

Page 28: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What is necessary for return loss Measurement?

Cable with stableproperties!

Calibrate here!

Use cable with best possible return loss! Impact from return loss is reduced by theround trip insertion loss (attenuation)!

Direction ofmeasurement

Permanent link starts

Permanent link ends

This requires ahigh qualityinterconnect!

Page 29: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Cable w/ stable properties!Calibrate here!

Use cable with best possiblereturn loss!

Direction ofmeasurement

Permanent link ends

Permanent link starts

This requires a highqualityinterconnect!

Measure inoppositedirection!

What is necessary for return loss Measurement?

Page 30: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

• A rugged, high-performance link interfaceadapter for the DSP-4000Series testers

• Very accurately measuresthe performance of aninstalled twisted-paircabling system

DSP-LIA101S PermanentLink Interface Adapter

A major improvement!

Page 31: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

0.00.51.01.52.02.53.03.54.04.55.0

0 50 100 150 200 250Frequency in MHz

Mea

sure

men

t Acc

urac

y in

dB

Cat 6 Return Loss Accuracy– Level IIIPermanent Link Level III per Standard(with adapter attached to tester)This is what tester manufacturers try to meet!

But how accurate is theDSP-LIA101S Permanent

Link Adapter?More

Accurate

LessAccurate

Tester Baseline Level III per Standard (no adapter attached)

Page 32: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

0.00.51.01.52.02.53.03.54.04.55.0

0 50 100 150 200 250

Tester Baseline Level III per Standard (no adapter attached)

Frequency in MHz

Mea

sure

men

t Acc

urac

y in

dB

Cat 6 Return Loss Accuracy– Level III

MoreAccurate

LessAccurate

Permanent Link Level III per Standard(with adapter attached to tester)This is what tester manufacturers try to meet!

DSP-4000 Series with DSP-LIA101SOut-of-the-box, our Permanent Link Adaptersolution is far more accurate than any other

tester with a twisted-pair adapter!

Page 33: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

But you can do better yet...Field Calibration

of thePermanent Link Interface

Adapter

Page 34: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

A simple calibration of the adapter cable

This is a “Network Analyzer” Calibration.

DSP-PLCALCalibration Artifacts

OPEN LOAD

SHORT

• Apply a technique used in the laboratory:one-port calibration

• The Personality Module is simply replacedwith “Calibration Artifacts”: Open, Short, and100 ΩΩΩΩ Load

Page 35: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Overview of adapter calibration process• Main and remote units are originally calibrated• Calibration for Return Loss can be executed by customer

with DSP-PLCAL kit (optional equip.)– A highly automated process – takes only minutes– Cal constants are stored in the adapter Flash EPROM– The adapters must be used with the DSP-4X00 with

which they have been calibrated

Calibrate only twice a year for “better-than-new” performance...

Page 36: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

0.00.51.01.52.02.53.03.54.04.55.0

0 50 100 150 200 250

Tester Baseline Level III per Standard (no adapter attached)

Frequency in MHz

Mea

sure

men

t Acc

urac

y in

dB

Cat 6 Return Loss Accuracy– Level III

MoreAccurate

LessAccurate

Permanent Link Level III per Standard(with adapter attached to tester)This is what tester manufacturers try to meet!

DSP-4000 Series with DSP-LIA101S

This is exceptional performance!

DSP-4000 Series with DSP-LIA101S– AFTER FIELD CAL –

Page 37: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Advantages of DSP-LIA101 with calibration

• Extend the life of the DSP-LIA101S indefinitely– Restore the measurement performance of the

adapter to better than “new”– Any aging effect due to coiling and uncoiling is

compensated– “The last adapter you’ll ever buy”

• Increase the accuracy of the RL measurement– Much lower probability of any “false failures”– More accuracy = more PASS results

Page 38: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

NEXT Interoperability is a challengeCat 6 plugs and jacks remain proprietary designs• The jack compensates the electrical performance of

the plug NEXT performance• Vendors have implemented unique combinations to

achieve Cat 6 performance for the ‘connection’• Many combinations from different vendors perform

worse than vendor-matched components• This is the reason for the many Cat 6 Basic Link

Adapters in use

Page 39: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

The DSP-LIA101S solution for NEXT

• The Permanent Link Adapter plug is modular• The removable 8-pin plug can be replaced

with different “Personality Modules”• You need only one adapter set

Page 40: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

What is in the Personality Module?

The location of the reference plane of calibration is asclose as practically possible near the plug.

• A small circuitboard connectingto leads to the 8-pin modular plug.

• A PROM toidentify the probetip.

Page 41: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Personality Module interoperability matrix• NEXT performance is

excellent• Each Personality Module

covers many vendors• Other modules are under

development• Check the website…

www.flukenetworks.comfor the latest matrix update!!

Page 42: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Advantages of Personality Modules

• You only need one set of Link InterfaceAdapters: the DSP-LIA101S

• The standard module DSP-PM01 delivers Cat 6performance with at least 10 types of Cat 6jacks

• The modules meet all of the requirements forCat 6 and Cat 5e (and Cat 3)

• Easy to store and carry• A set costs only half as much as a Basic Link

Adapter set

Page 43: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Standards for field test

Level ofPerformance

ApplicableStandards

Cabling System tobe tested

Level I and II TIA TSB-67 (*) TIA category 5TIA TSB-95 (*) Minimum Gigabit Ethernet

(TIA category 5 with RL,ELFEXT and PSELFEXT)

TIA/EIA-568-A-5TIA/EIA-568-B.2

TIA Enhanced category 5

Level IIe

IEC 61935-1 ISO/IEC 11801-2000 Class DTIA/EIA-568-B Addendum 1 TIA category 6Level IIIRev. 1 to IEC 61935-1 ISO/IEC 11801-2000 Class E

(*) These TSB documents will be obsolete with the approval of TIA-568-BEntries in red are draft specification

Page 44: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Page 45: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Page 46: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

DSP-LIA101S Benefits for End-Users

• Get an accurate picture of performance of thePermanent Link configuration– Only the cabling that is part of the infrastructure –

fixed and permanent.• Get assurance that investment in cabling

infrastructure will deliver reliable long-term service• Add good patch cords and/or equipment cords to

obtain high performance channels• Certify the cabling installation in perfect compliance

with the new industry standard

Page 47: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Benefits for Contractors and Installers

• Carry only one set of tester interface adapters thatwill last virtually indefinitely

• Save time and money by measuring NEXT andReturn Loss with the accuracy of lab equipment–Get more PASS results; reduce false failures

• If the plug is damaged, replace only a PersonalityModule

• Restore the performance to “better than newcondition” with a simple calibration procedure

Page 48: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Which tests must be execute ?Which tests must be execute ?

Page 49: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

CAT 5e / 6 Cable CertificationCAT 5e / 6 Cable Certification

WIRING CLOSETWIRING CLOSET

HORIZONTAL CABLE

WALL OUTLET

WORK AREAWORK AREAPATCHPANEL

DSP-4300

Smart Remote

Just Push Test!

Page 50: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Autotest Results• Indication of overall pass or

fail• Summary of all tests

performed and required bythe chosen standard

Push the “View Result”button to reviewindividual tests

Remember to push “SAVE”

Page 51: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

If the tests fail Push Fault Info

Time Domain X-Talk AnalyzerAutomated Fault Info

Find the fault and then analyze the fault

Unique Digital Test Technology

Page 52: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Test Results Management --Removable Memory Card

• Utilizes standard Sandisk MMC’s– Standard card: 16 Mbytes, 300 complete tests– Optional card: 32 Mbytes, 600 complete tests

• Separate card reader includedin package -- Keep the DSP inthe field, not the office!

• Eliminate the need to re-test!Store every measurement value for everyapplicable test parameter with the DSP-4300.

Page 53: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Test Results Management --Cable ManagerTM Software

• CableManager shareware allows you toquicklyand easily:– Organize– Merge (append)– Sort up to

5000 Reports– Find– Edit– Export– Print

Works in Windows 95, 98, NT4.0, and Windows 2000

Page 54: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Test Results Management --Printed Reports• DSP Cable Management

Software supports severalalternatives to provide testresults information to yourcustomer:– Graphical color report with

measured test points over fullfrequency range (1 - 350 Mhz)

– Text format with worst caseand worst value data

– Summary report whichprovides a list of the cablinglinks tested and keyinformation

Page 55: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Fiber Optic Test Adapters

• Productivity:Automatic and Fast

• Test two fibers in a link attwo wave-lengths

• Automatically calculatespass/fail limits based onfiber test standards

• Provides documentedcertification of test results

Page 56: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

Fiber Test AdaptersFiber Application Standard Sources Test Tool

Multimode

100BaseFX10 BaseFLFDDIATMToken RingDemand Priority

LED 850LED 1300 DSP-FTA420S

1000BaseSX (GbE)ATMFibre Channel (GbFC)

VCSEL 850nm

FP Laser 1310nmDSP-FTA440S

Singlemode

1000BaseLX (GbE)Fibre Channel (GbFC) FP Laser 1310nm

FP Laser 1550nm DSP-FTA430S

NEW!

Page 57: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

DSP-FTA440SGreen Band• VCSEL 850nm• 1310nm Laser

DSP-FTA420SSolid Grey• 850 nm LED• 1300 nm LED

DSP-FTA430SYellow Band• 1310nm Laser• 1550nm Laser

Fiber Optic Test Adapters

Page 58: 3 standard per la cat 6 e i nuovi strumenti di mi sura ...web.diegm.uniud.it/pierluca/public_html/teaching/... · N E T W O R K S U P E R V I S I O N maurizio.malinconi@flukenetworks.com

N E T W O R K S U P E R V I S I O N

N E T W O R K S U P E R V I S I O N

We have our eye on the future for you.