N E T W O R K S U P E R V I S I O N
Gli standard per la categoria 6 e i nuovi strumenti di misura
"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LACERTIFICA SUL CAMPO DEI PARAMETRI
TRASMISSIVI FINO A 250 MHZ"
N E T W O R K S U P E R V I S I O N
What is Fluke Networks, Inc. today?
• A stand-alone company set apart fromFluke Corporation in May, 2000, to createan even more tightly aligned, customer-needs driven organization
• ~ $200M in annual revenues• Over 500 associates worldwide• Combines the best of Fluke’s heritage for
quality and reliability with network know-how and a strong entrepreneurial spirit
N E T W O R K S U P E R V I S I O N
What we provide
HouseHouse
House
House
House
Internet /TelephonyNetwork
Servers
SharedWorkgroup
Router
RemoteOffice
Router
SwitchedWorkgroup
OSP/TelecomEnterprise Networks
Copper and Fiber Structured Cabling
OSP/Telecom:Local Loop Recovery
Documentation &Reporting
DSL QualificationTroubleshooting
Enterprise Networks:Performance Analysis
Monitoring & TroubleshootingReporting & Documentation
Moves, Adds, & Changes
Copper & FiberStructured Cabling:
CertificationDocumentation &
ReportingInspection
Troubleshooting
N E T W O R K S U P E R V I S I O N
•48 Countries
•220 Sales Professionals
•1800 Distribution Outlets
•50% of our sales come from outside the US
•75% of 2001 revenue was generated by newproducts introduced in 2000 and 2001
•Profitable and Growing
N E T W O R K S U P E R V I S I O N
What Does Fluke Networks Do?
We deliver
What is that supposed to mean?
N E T W O R K S U P E R V I S I O N
We offer more ways to look at your network:
Hardware Software
Physical Application
LAN WAN
Portable Distributed
N E T W O R K S U P E R V I S I O N
http://www.flukenetworks.com
N E T W O R K S U P E R V I S I O N
http://www.fluke-net.com/consultants
N E T W O R K S U P E R V I S I O N
568-A Has Changed to 568-B
ANSI/TIA/EIA568-A-1995
568-A
ANSI/TIA/EIA 568-B-2001
=B.1 General Reqmts
B.2 Copper
B.3 Fiber
568-B.1
=568-B.3
568-B.2
N E T W O R K S U P E R V I S I O N
What’s going away?• TIA/EIA TSB67• TIA/EIA TSB72• TIA/EIA TSB75• TIA/EIA TSB95• ANSI/TIA/EIA568A1• ANSI/TIA/EIA568A2• ANSI/TIA/EIA568A3• ANSI/TIA/EIA568A4• ANSI/TIA/EIA568A5• TIA/EIA/IS729
B.1 General Reqmts
B.2 Copper
B.3 Fiber
568-B.1
568-B.3
568-B.2
N E T W O R K S U P E R V I S I O N
TIA adopts the “Permanent Link”
TIA harmonizes with ISOThe revised TIA standards
no longer specify Basic Link
N E T W O R K S U P E R V I S I O N
USER’SPATCHCORD
PATCHPANEL
HORIZONTAL CABLE
TelecomOutlet
USER’SPATCHCORD
FLOOR DISTRIBUTORFLOOR DISTRIBUTORWORKWORKAREAAREA
ChannelEnd
ChannelEnd
Two transitions at each end
CP
Link Definition: “Channel”
CP: Consolidation Point
N E T W O R K S U P E R V I S I O N
WORK AREAWORK AREA
Link End
HORIZONTAL CABLE
TelecomOutlet
TESTERPATCHCORD
Link End
TESTERPATCHCORD
PATCHPANEL
FLOOR DISTRIBUTORFLOOR DISTRIBUTOR
One transition at each endTester patch cables max. 2 m long
Link Definition: “Basic Link”
N E T W O R K S U P E R V I S I O N
We used to test the Basic Link
The Basic Link starts and ends at thetester itself, and it includes the adaptercords
Telecommunication Room Work Area
Patch Panel Outlet90 meter max
Includes TesterAdapter Cords
Basic Link
N E T W O R K S U P E R V I S I O N
Telecommunication Room Work Area
Patch Panel Outlet90 meter max
Includes TesterAdapter Cords
Basic Link
But the Basic Link is obsolete
Per TIA/EIA-568-B, the Permanent Linkmodel replaces the Basic Link model
N E T W O R K S U P E R V I S I O N
Basic Link Weaknesses• Developing new Cat 5e specifications
revealed some new challenges– Return Loss became a critical parameter that
had not been considered before– Stranded UTP used in patch cables (and cable
tester cords) was found to be very unstable andmajor cause of poor Return Loss performance.
– The Basic Link definition included 4 meters ofcable tester cords in the performance limits,test methods, and test results!
N E T W O R K S U P E R V I S I O N
Link End
TESTERPATCHCORD
TelecomOutlet
TESTERPATCHCORD
WORK AREAWORK AREA
PatchPanel
HORIZONTAL CABLE
FLOOR DISTRIBUTORFLOOR DISTRIBUTOR
Test results do not includecontributions by the tester patch
cablesLink End
CP
Link Definition: “Permanent Link”
CP: Consolidation Point
N E T W O R K S U P E R V I S I O N
What is a “permanent link”?
• The fixed cabling in the walls – the“permanent” part of the buildinginfrastructure
• The link model to be used for testingthe “fixed” portion of a cablinginstallation
• This excludes users’ patch cables andequipment cords
• This excludes tester adapter cords, too
N E T W O R K S U P E R V I S I O N
A detailed look at the Permanent LinkThe Permanent Link is the permanentcabling, and it does not include theadapter cords
Permanent Link
Consolidation Point (optional)
Does NOT includeTester Adapter Cords
Telecommunication Room Work Area
PatchPanel
Outlet
N E T W O R K S U P E R V I S I O N
The purpose of field test• Accurately characterize the fixed portion of the data
cabling installation upon completion of theinstallation
• Network equipment, patch cables and equipmentcables are changed many times during the life spanof the fixed portion of the cabling (the infrastructure)
• Provide guarantee that the ‘Channel’ meets thenetwork’s requirements by connecting good patchcords
N E T W O R K S U P E R V I S I O N
Cat 5e and Cat 6 test problems
Measured CalculatedWire mapPropagation delay Length, Delay SkewAttenuationNEXT (pair-to-pair) PSNEXT, ACR, PSACRFEXT (pair-to-pair) ELFEXT, PSELFEXTReturn Loss
There are two measured parameters thatpresent serious accuracy problems that arevery difficult for testers to correct
N E T W O R K S U P E R V I S I O N
Return Loss is a major challenge
Permanent Link
Measured separately from both ends, ReturnLoss is a measure of reflected signal(undesirable)
The Return Loss that should be measured, which isattenuated by the link, is within the link:
(Reflections occur wherever there arechanges in impedance, such as bends, twist
variations, terminations, connectors, etc.)
N E T W O R K S U P E R V I S I O N
Return Loss is a major challenge
Permanent Link
Measured separately from both ends, ReturnLoss is a measure of reflected signal(undesirable)
The Return Loss that should be measured, which isattenuated by the link, is within the link:
But Return Loss in the tester’s adapter cords addsmeasurement error and must be eliminated – and there is only one solution – the DSP-LIA101S!
N E T W O R K S U P E R V I S I O N
The impact of twisted-pair adapters
• Twisted-pair adapters degrade withhandling and use in the field – ReturnLoss margin can drop significantly
• Permanent links that are good – but closeto the limit – can produce false failures
• Permanent links that are very good canstill yield poor test results – becausetwisted-pair tester adapters contribute toReturn Loss!
Use the DSP-LIA101S to PASS!
N E T W O R K S U P E R V I S I O N
Return Loss of twisted-pair adapter
0
5
10
15
20
25
30
35
40
45
50
0 50 100 150 200 250 300 350 400
CAT6 BLBL +12dBInitial50 cyc100 cyc200 cycCable Lim
21-7*LOG(f/20)
26-12*LOG(f/100)
Basic Link
BL + 12 dB
Impact of handling and “aging”- Sample 1
Frequency (MHz)
Ret
urn
Loss
(dB
)
N E T W O R K S U P E R V I S I O N
Correction for adapter cableTest parameter Effect of tester patch cable
Attenuation Stable – Corrected
LengthPropagation delay
Stable – Corrected
NEXT & FEXT High Quality patch cord(PiMF or SSTP) hasnegligible crosstalk
Return Loss Unpredictablllle !!
N E T W O R K S U P E R V I S I O N
Requirements for accurate Return Loss
The tester’s permanent link interface cableitself must have very good return losscharacteristics1. Impedance very close to 100 ΩΩΩΩ2. Very good Return Loss performance3. Stability: very stable impedancecharacteristic over time (after repeateduncoiling, testing, and recoiling to packwith tester)
N E T W O R K S U P E R V I S I O N
What is necessary for return loss Measurement?
Cable with stableproperties!
Calibrate here!
Use cable with best possible return loss! Impact from return loss is reduced by theround trip insertion loss (attenuation)!
Direction ofmeasurement
Permanent link starts
Permanent link ends
This requires ahigh qualityinterconnect!
N E T W O R K S U P E R V I S I O N
Cable w/ stable properties!Calibrate here!
Use cable with best possiblereturn loss!
Direction ofmeasurement
Permanent link ends
Permanent link starts
This requires a highqualityinterconnect!
Measure inoppositedirection!
What is necessary for return loss Measurement?
N E T W O R K S U P E R V I S I O N
• A rugged, high-performance link interfaceadapter for the DSP-4000Series testers
• Very accurately measuresthe performance of aninstalled twisted-paircabling system
DSP-LIA101S PermanentLink Interface Adapter
A major improvement!
N E T W O R K S U P E R V I S I O N
0.00.51.01.52.02.53.03.54.04.55.0
0 50 100 150 200 250Frequency in MHz
Mea
sure
men
t Acc
urac
y in
dB
Cat 6 Return Loss Accuracy– Level IIIPermanent Link Level III per Standard(with adapter attached to tester)This is what tester manufacturers try to meet!
But how accurate is theDSP-LIA101S Permanent
Link Adapter?More
Accurate
LessAccurate
Tester Baseline Level III per Standard (no adapter attached)
N E T W O R K S U P E R V I S I O N
0.00.51.01.52.02.53.03.54.04.55.0
0 50 100 150 200 250
Tester Baseline Level III per Standard (no adapter attached)
Frequency in MHz
Mea
sure
men
t Acc
urac
y in
dB
Cat 6 Return Loss Accuracy– Level III
MoreAccurate
LessAccurate
Permanent Link Level III per Standard(with adapter attached to tester)This is what tester manufacturers try to meet!
DSP-4000 Series with DSP-LIA101SOut-of-the-box, our Permanent Link Adaptersolution is far more accurate than any other
tester with a twisted-pair adapter!
N E T W O R K S U P E R V I S I O N
But you can do better yet...Field Calibration
of thePermanent Link Interface
Adapter
N E T W O R K S U P E R V I S I O N
A simple calibration of the adapter cable
This is a “Network Analyzer” Calibration.
DSP-PLCALCalibration Artifacts
OPEN LOAD
SHORT
• Apply a technique used in the laboratory:one-port calibration
• The Personality Module is simply replacedwith “Calibration Artifacts”: Open, Short, and100 ΩΩΩΩ Load
N E T W O R K S U P E R V I S I O N
Overview of adapter calibration process• Main and remote units are originally calibrated• Calibration for Return Loss can be executed by customer
with DSP-PLCAL kit (optional equip.)– A highly automated process – takes only minutes– Cal constants are stored in the adapter Flash EPROM– The adapters must be used with the DSP-4X00 with
which they have been calibrated
Calibrate only twice a year for “better-than-new” performance...
N E T W O R K S U P E R V I S I O N
0.00.51.01.52.02.53.03.54.04.55.0
0 50 100 150 200 250
Tester Baseline Level III per Standard (no adapter attached)
Frequency in MHz
Mea
sure
men
t Acc
urac
y in
dB
Cat 6 Return Loss Accuracy– Level III
MoreAccurate
LessAccurate
Permanent Link Level III per Standard(with adapter attached to tester)This is what tester manufacturers try to meet!
DSP-4000 Series with DSP-LIA101S
This is exceptional performance!
DSP-4000 Series with DSP-LIA101S– AFTER FIELD CAL –
N E T W O R K S U P E R V I S I O N
Advantages of DSP-LIA101 with calibration
• Extend the life of the DSP-LIA101S indefinitely– Restore the measurement performance of the
adapter to better than “new”– Any aging effect due to coiling and uncoiling is
compensated– “The last adapter you’ll ever buy”
• Increase the accuracy of the RL measurement– Much lower probability of any “false failures”– More accuracy = more PASS results
N E T W O R K S U P E R V I S I O N
NEXT Interoperability is a challengeCat 6 plugs and jacks remain proprietary designs• The jack compensates the electrical performance of
the plug NEXT performance• Vendors have implemented unique combinations to
achieve Cat 6 performance for the ‘connection’• Many combinations from different vendors perform
worse than vendor-matched components• This is the reason for the many Cat 6 Basic Link
Adapters in use
N E T W O R K S U P E R V I S I O N
The DSP-LIA101S solution for NEXT
• The Permanent Link Adapter plug is modular• The removable 8-pin plug can be replaced
with different “Personality Modules”• You need only one adapter set
N E T W O R K S U P E R V I S I O N
What is in the Personality Module?
The location of the reference plane of calibration is asclose as practically possible near the plug.
• A small circuitboard connectingto leads to the 8-pin modular plug.
• A PROM toidentify the probetip.
N E T W O R K S U P E R V I S I O N
Personality Module interoperability matrix• NEXT performance is
excellent• Each Personality Module
covers many vendors• Other modules are under
development• Check the website…
www.flukenetworks.comfor the latest matrix update!!
N E T W O R K S U P E R V I S I O N
Advantages of Personality Modules
• You only need one set of Link InterfaceAdapters: the DSP-LIA101S
• The standard module DSP-PM01 delivers Cat 6performance with at least 10 types of Cat 6jacks
• The modules meet all of the requirements forCat 6 and Cat 5e (and Cat 3)
• Easy to store and carry• A set costs only half as much as a Basic Link
Adapter set
N E T W O R K S U P E R V I S I O N
Standards for field test
Level ofPerformance
ApplicableStandards
Cabling System tobe tested
Level I and II TIA TSB-67 (*) TIA category 5TIA TSB-95 (*) Minimum Gigabit Ethernet
(TIA category 5 with RL,ELFEXT and PSELFEXT)
TIA/EIA-568-A-5TIA/EIA-568-B.2
TIA Enhanced category 5
Level IIe
IEC 61935-1 ISO/IEC 11801-2000 Class DTIA/EIA-568-B Addendum 1 TIA category 6Level IIIRev. 1 to IEC 61935-1 ISO/IEC 11801-2000 Class E
(*) These TSB documents will be obsolete with the approval of TIA-568-BEntries in red are draft specification
N E T W O R K S U P E R V I S I O N
N E T W O R K S U P E R V I S I O N
N E T W O R K S U P E R V I S I O N
DSP-LIA101S Benefits for End-Users
• Get an accurate picture of performance of thePermanent Link configuration– Only the cabling that is part of the infrastructure –
fixed and permanent.• Get assurance that investment in cabling
infrastructure will deliver reliable long-term service• Add good patch cords and/or equipment cords to
obtain high performance channels• Certify the cabling installation in perfect compliance
with the new industry standard
N E T W O R K S U P E R V I S I O N
Benefits for Contractors and Installers
• Carry only one set of tester interface adapters thatwill last virtually indefinitely
• Save time and money by measuring NEXT andReturn Loss with the accuracy of lab equipment–Get more PASS results; reduce false failures
• If the plug is damaged, replace only a PersonalityModule
• Restore the performance to “better than newcondition” with a simple calibration procedure
N E T W O R K S U P E R V I S I O N
Which tests must be execute ?Which tests must be execute ?
N E T W O R K S U P E R V I S I O N
CAT 5e / 6 Cable CertificationCAT 5e / 6 Cable Certification
WIRING CLOSETWIRING CLOSET
HORIZONTAL CABLE
WALL OUTLET
WORK AREAWORK AREAPATCHPANEL
DSP-4300
Smart Remote
Just Push Test!
N E T W O R K S U P E R V I S I O N
Autotest Results• Indication of overall pass or
fail• Summary of all tests
performed and required bythe chosen standard
Push the “View Result”button to reviewindividual tests
Remember to push “SAVE”
N E T W O R K S U P E R V I S I O N
If the tests fail Push Fault Info
Time Domain X-Talk AnalyzerAutomated Fault Info
Find the fault and then analyze the fault
Unique Digital Test Technology
N E T W O R K S U P E R V I S I O N
Test Results Management --Removable Memory Card
• Utilizes standard Sandisk MMC’s– Standard card: 16 Mbytes, 300 complete tests– Optional card: 32 Mbytes, 600 complete tests
• Separate card reader includedin package -- Keep the DSP inthe field, not the office!
• Eliminate the need to re-test!Store every measurement value for everyapplicable test parameter with the DSP-4300.
N E T W O R K S U P E R V I S I O N
Test Results Management --Cable ManagerTM Software
• CableManager shareware allows you toquicklyand easily:– Organize– Merge (append)– Sort up to
5000 Reports– Find– Edit– Export– Print
Works in Windows 95, 98, NT4.0, and Windows 2000
N E T W O R K S U P E R V I S I O N
Test Results Management --Printed Reports• DSP Cable Management
Software supports severalalternatives to provide testresults information to yourcustomer:– Graphical color report with
measured test points over fullfrequency range (1 - 350 Mhz)
– Text format with worst caseand worst value data
– Summary report whichprovides a list of the cablinglinks tested and keyinformation
N E T W O R K S U P E R V I S I O N
Fiber Optic Test Adapters
• Productivity:Automatic and Fast
• Test two fibers in a link attwo wave-lengths
• Automatically calculatespass/fail limits based onfiber test standards
• Provides documentedcertification of test results
N E T W O R K S U P E R V I S I O N
Fiber Test AdaptersFiber Application Standard Sources Test Tool
Multimode
100BaseFX10 BaseFLFDDIATMToken RingDemand Priority
LED 850LED 1300 DSP-FTA420S
1000BaseSX (GbE)ATMFibre Channel (GbFC)
VCSEL 850nm
FP Laser 1310nmDSP-FTA440S
Singlemode
1000BaseLX (GbE)Fibre Channel (GbFC) FP Laser 1310nm
FP Laser 1550nm DSP-FTA430S
NEW!
N E T W O R K S U P E R V I S I O N
DSP-FTA440SGreen Band• VCSEL 850nm• 1310nm Laser
DSP-FTA420SSolid Grey• 850 nm LED• 1300 nm LED
DSP-FTA430SYellow Band• 1310nm Laser• 1550nm Laser
Fiber Optic Test Adapters
N E T W O R K S U P E R V I S I O N
N E T W O R K S U P E R V I S I O N
We have our eye on the future for you.
Thank you !
for more info :[email protected]