29Li-3_4-A

8
Air curtains type „Li 3, 4“ Air curtains type „Li 3, 4“ Air curtains type „Li 3, 4“ ‘05

description

A ir c u r t a in s t y p e „ L i 3 , 4 “ A ir c u r t a in s t y p e „ L i 3 , 4 “ A ir c u r t a in s t y p e „ L i 3 , 4 “ ‘05

Transcript of 29Li-3_4-A

Page 1: 29Li-3_4-A

Air c

urta

ins

type

„Li 3

, 4“

Air c

urta

ins

type

„Li 3

, 4“

Air c

urta

ins

type

„Li 3

, 4“

‘05

Page 2: 29Li-3_4-A

Contents:

Planning of air curtains .................................................................................... Page 2Technical data - dimensions „Li3“ .................................................................. Page 3Technical data - dimensions „Li4“ .................................................................. Page 3Technical data - capacity .................................................................................. Page 4Underview air curtains „Li3“............................................................................ Page 5Accessories to the air curtains ........................................................................ Page 6Operating the air curtains ................................................................................ Page 7Air curtains types .............................................................................................. Page 7Order key .......................................................................................................... Page 8

Air curtains doors are preferablydesignated for use in:

◆ banks and hotels◆ administration buildings◆ light industry◆ trade fair halls, convention or

exhibition centres, and supermarkets.

Model „Li4“Model „Li3“

As a separating medium:

◆ circulation air of room temperature◆ circulation of air heated by electrical

or hot water heater◆ outside air and circulating air heated

by electrical or hot water heater(on demand) can be used.

03/05Page 2 Te c h n i c a l A m e n d m e n t s r e s e r v e d

Air curtains doors type „Li 3, 4“

Assembly: vertical / horizontalTypes: cold air / hot air

(hot water, electrical or steam heated)For door heights of: to 4,2; to 4,8mFor door widths of: 1,5; 2,0; 2,5 mColour: Standard RAL 9010 (white),

optional: all RAL- colours

The air curtains in these types are also suitable for interiorareas, whereby substantial demands in design arefeatured.The air curtains in these types are also furnished asstandard and with EU2-filter, which renders animportant contribution for air purity.

Page 3: 29Li-3_4-A

Technical data

Page 303/05 Te c h n i c a l A m e n d m e n t s r e s e r v e d

Air curtains type „Li 3, 4“

„Li 3“

„Li 4“

M10

airinlet

heater in right side furnishing

f

D

n

me

o

pc

j

n

k l kl

a V

electric

G 5/4" -2"

H

airinlet

airoutlet

airinlet

M10

airinlet

heater in right side furnishing

f

D

n

me

o

j'p

cj

n

k l kl

a V

electric

G 3/4"

construction withthermostatic valve

H

airinlet

Page 4: 29Li-3_4-A

03/05Page 4 Te c h n i c a l A m e n d m e n t s r e s e r v e d

Air curtains type „Li 3, 4“Technical data

Air curtains type THCP THCP THCP THCP THCP THCP

150-3- 200-3- 250-3- 150-3- 200-3- 250-3-

Li3 Li3 Li3 Li4 Li4 Li4

Air outlet aperture height [m] 4,0 4,0 4,0 4,8 4,8 4,8

Dimensions length D [mm] 1500 2000 2470 1500 2000 2470

of the unit width V [mm] 450 450 450 550 550 550

depth H [mm] 785 785 785 1000 1000 1000

Dimensions width a [mm] 410 410 410 780 780 780

the air suction grid length b [mm] D-50 D-50 D-50 D-50 D-50 D-50

Dimensions width c [mm] 140 140 140 170 170 170

the air outlet grid length d [mm] D-50 D-50 D-50 D-50 D-50 D-50

Assembly m [mm] 46 46 46 48 48 48

n [mm] 12,5 12,5 12,5 12,5 12,5 12,5

o [mm] 80 80 80 97 97 97

e [mm] 660 660 660 855 855 855

f [mm] 1475 1975 2445 1475 1975 2445

Connections k [mm] 61,5 61,5 61,5 61,5 61,5 61,5

l [mm] 50 50 50 50 50 50

p [mm] 114 114 114 650 650 650

j [mm] 28 28 28 50 50 50

j’ [mm] 216 216 216 -- -- --

Technical data THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP THCP150-3- 150-3- 200-3- 200-3- 250-3- 250-3- 150-3- 150-3- 150-3- 200-3- 200-3- 200-3- 250-3- 250-3- 250-3-

Li3 Li3 Li3 Li3 Li3 Li3 Li4 Li4 Li4 Li4 Li4 Li4 Li4 Li4 Li4V N V N V N V N NN V N NN V N NN

Air- handling capacity [m3/h] 8350 8000 11500 11200 14500 14250 10200 10000 9800 14400 14000 13700 18000 17500 17100

Hot water heater (water 80/60°C)ti =18°C capacity ** [kW] 30,6 58,6 46,0 61,1 39,8 75,9 41,8 76,4 86,0 59,0 108,4 122,6 77,3 134,2 154,2

pressure loss [kPa] 3,1 16,9 7,9 12,5 6,8 20,6 15,5 28,1 23,2 7,1 23,8 23,5 13,9 11,6 17,3flow volume rate [m3/h] 1,29 2,48 1,94 2,59 1,69 3,24 1,72 3,24 3,67 2,52 4,60 5,25 3,31 5,76 6,62

Hot water heater (water 60/40°C)ti =18°C capacity ** [kW] 15,4 32,6 24,5 34,4 21,7 43,1 22,5 43,1 46,0 31,2 61,2 71,0 42,1 74,2 88,8

pressure loss [kPa] 0,9 6,3 2,7 4,7 2,5 8,0 5,5 10,8 8,1 2,5 9,1 9,5 5,0 4,3 6,8flow volume rate [m3/h] 0,65 1,37 1,04 1,44 0,90 1,84 0,94 1,80 1,95 1,29 2,59 3,02 1,80 3,16 3,81

Hot water heater (water 80/60°C)ti =20°C capacity ** [kW] 29,2 56,1 43,9 58,5 38,1 72,7 40,0 73,2 82,4 56,4 103,9 117,6 73,8 128,6 147,8

pressure loss [kPa] 2,8 15,6 7,3 11,5 6,3 19,1 14,3 26,0 21,5 6,6 22,1 21,9 12,8 10,8 15,6flow volume rate [m3/h] 1,22 2,37 1,87 2,48 1,62 3,09 1,65 3,09 3,52 2,37 4,46 5,04 3,16 5,47 6,33

Hot water heater (water 60/40°C)ti =15°C capacity ** [kW] 17,5 36,4 27,5 38,3 24,3 47,9 20,9 39,8 55,0 28,6 56,6 78,6 38,8 68,4 98,4

pressure loss [kPa] 1,2 7,7 3,4 5,8 3,0 9,6 4,7 9,4 11,1 2,1 7,9 11,3 4,3 3,7 8,2flow volume rate [m3/h] 0,72 1,55 1,15 1,62 1,04 2,05 0,86 1,65 2,30 1,22 2,37 3,31 1,65 2,88 4,18

Hot water heater (water 60/30°C)ti =15°C capacity ** [kW] 10,2 25,6 25,6 27,5 16,5 34,9 25,2 47,9 41,0 35,2 68,0 58,8 47,1 82,8 73,2

pressure loss [kPa] 0,2 2,0 2,0 1,6 0,7 2,7 6,7 13,1 3,2 3,0 11,0 3,3 6,1 5,3 2,4flow volume rate [m3/h] 0,29 0,72 0,72 0,76 0,47 0,97 1,08 2,02 1,15 1,44 2,88 1,65 2,02 3,53 2,09

Electrical heater ** capacity [kW] On demand, voltage *** 400 V; number of grades 3

Fanfan power [W] 1050 1050 1400 1400 1750 1750 1050 1050 1050 1400 1400 1400 1750 1750 1750fan current [A] 9 9 12 12 15 15 11,4 11,4 11,4 15,2 15,2 15,2 19,0 19,0 19,0fan voltage [V] 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230

Operating device typecold, hot water heated air curtain door LS +, LS-A, LS-X, LS-X/A, Digitron-W, Digitron-W/A

Degree of protection IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

Weight [kg] 140 150 168 180 200 215 150 170 175 180 195 200 225 250 255

**) On customer wish it is possible to deliver heaters with modified or higher capacities***) Atypically can be delivered electric heater in voltage 3x 230 V

Technical data SHCP SHCP SHCP SHCP SHCP SHCP

150-3- 200-3- 250-3- 150-3- 200-3- 250-3-

Li3 Li3 Li3 Li4 Li4 Li4

Air- handling capacity[m3/h] 8500 12000 15000 10800 14800 18200

Fan

fan power [W] 1050 1400 1750 1050 1400 1750

fan current [A] 9 12 15 11,4 15,2 19,0

fan voltage [V] 230 230 230 230 230 230

Operating device type

cold, air curtain door LS +, LS-A, LS-X, LS-X/A, Digitron-W, Digitron-W/A

Degree of protection IP55 IP55 IP55 IP55 IP55 IP55

Weight [kg] 126 151 180 135 162 203

Page 5: 29Li-3_4-A

Underview air curtains

Page 503/05 Te c h n i c a l A m e n d m e n t s r e s e r v e d

Air curtains type „Li 3, 4“

The grills for underceiling air curtains are by default delivered as natural anodized aluminiumevent. in RAL 9010 (whithe colour). On wish it is possible to deliver all colour shades RAL.

Alternative suspension

for underceilingair curtains

D

1275

450

Li3=140

min.100max.150*

Li3 = 565

*) alt. min.180; max.230 mm

WARNING:air curtains for underceilingusage can be delivered only

in the design Li3!

D

Li3= 1275

1

2

3

4

5

Standard suspensiontype A

for standard model

Air curtainssuspension

Page 6: 29Li-3_4-A

Accessories

03/05Page 6 Te c h n i c a l A m e n d m e n t s r e s e r v e d

Air curtains type „Li 3, 4“

Thermostatic head for2-way or 3-way valveAt customer wish the hot water heat exchanger can be delivered with a built-in 2-way or 3-way thermostatic valve with operating head (range 20-50°C). A part of the operating head is a capillary sensor, which is installed behind the heat exchanger - for exit air and temperature regulation.

3-way valveOn customer wish can be delivered to the heat exchanger an inbuilt 3-way valvewith operating thermosatic head (range 20-50°C) or with an electro-thermic gear.During switching the 3-way valve doesn’toccur any pressure strokes and the valve isrunning also in interpositions. A part of thethermostatic head is a separate capillarysensor, which is placed in the productionbehind the heat exchanger - temperatureregulation of the outlet air.

Electrothermic gear for2-way or 3-way valveAt customer wish the hot water heat exchanger can be delivered with a built-in 2-way or 3-way thermoelectricvalve. It is characterized by silent and trouble-free running. When the thermo gear is under voltage, built-in sensor is warming up, after lapse a time differential, the gear starts to close continuously. At voltage interruption come to a continuous opening of thermo gear. Electro data: 230 V/50Hz-3V, IP 42.

kv“** admissible admissible admissible differential3-way valve value operating temperature operating overpressure pressure

[°C] [bar] p [bar]

DN 25 (1“) 4,6 100 10 0,50DN 32 (5/4“) 6,4 100 10 0,25DN 32 XXL (5/4“)* 10,0 120 10 0,20DN 40 XXL (2“)* 12,0 120 10 0,20* only with electrothermic drive

50

0,2

0,3

0,5

1

2

3

5

10

20

30

0,1Pre

ssure

loss

∆p [kP

a]

Flow quantity [kg/h]

100 200 300 500 1000 2000 3000 4000 5000

500

300

200

100

50

30

20

10

5

3

2

1 10

20

30

50

100

200

300

500

1000

2000

3000

5000

Pre

ssure

loss

∆p [m

bar]

Pre

ssure

loss

∆p [m

m v

.sl.]

DN 25 (kvs 4,6)

DN 32 (kvs 6,4)

DN 32 XXL (kvs 10,0)

DN 40 XXL (kvs 12,0)

2-way valveOn customer wish can be delivered to the heat exchanger an inbuilt 2-way valve with operating thermostatic head(range 20-50°C). The valve’s body isproduced of corrosion-proof bronze. The valve is characterized by especiallysmall hydraulic resistance. The completetop part of the valve is exchangeableduring the unit running. Max. temperature 120°C.

30

20

0,2

0,3

0,5

1

2

3

5

10

20

30

0,1Pre

ssu

re lo

ss ∆

p [

kPa

]

Flow quantity [kg/h]

50 100 200 300 500 1000 2000 3000

DN 25 (1")DN 32 (11/4") DN 25 XXL (1")

kv“** admissible admissible admissible differential2-way valve value operating temperature operating overpressure pressure

[°C] [bar] p [bar]

DN 25 (1“) 2,5 120 10 0,25DN 32 (5/4“) 3,8 120 10 0,25DN 25 XXL (1“)* 4,3 120 16 0,20* highly - flow valve** for DN25, 32 is valid for [K] 3.0; for DN25 XXL is valid for [K] 6.0

Page 7: 29Li-3_4-A

Page 703/05 Te c h n i c a l A m e n d m e n t s r e s e r v e d

Operating for the air curtains

Air curtains type „Li“ - horizontal or vertical

Type „HC“„XX0“

(for length see orderkey page 8)

Type „VC“*„XX0“

(for length see orderkey page 8)

Air curtains type „Li 3, 4“

Table of operating devices for hot water or cold models „Li“Type of controller Table of functions

Fan speed Fan speed Preparing for control Air curtain’s Switch of the function Preparing forregulation regulation 0-1-2 by door or external time delay for door contact DK control by room

0-1-2-3 automatically contact 24V (DK) 5 s. - 10hours ON -OFF thermostat (PT)LS + ● — ● ● — ●

LS-A ● — ● ● ● ●

LS-X — ● ● ● — ●

LS-XA — ● ● ● ● ●

Digitron-W ● — ● ● ● ●

Digitron-WA — ● ● ● ● ●

Controller LS +, LS-A, Digitron-WController description: it is designated for operation of cold or warm air curtains with a connection possibility from external operating elements (doorcontact, room thermostat), fan operating 0-1-2-3; see table of controllers.

LS-A, Digitron-W is equiped, compared to LS+, with a switch ON/OFF door contact (DK) - changeover to manual operation.

Digitron-W - this controller is suitable first of all for representativ areas event. sophisticated interiors. The operation is done over an open foil control keyboard. In case, that the air curtain is connected with a room thermostat (PT), then the room thermostat operates the fan or in case thermo-electric valveequipage the room thermostat operates the thermo-valve of the air curtain.

Attention: with chaining possibility of the air curtains to one controller

Controller LS-X, LS-XA, Digitron-WAController description: it is designated for operation of cold or warm air curtain doorswith a connection possibility from external operating elements (door contact, room thermostat). Especially it is suitable for aplication with a big frequency of people movingthroug the door. The automatic function is secured by door contact (contact from thedoor automatics in the building), where the air curtain is running on the lowest speedgrade, when the door is closed. When the door opens, it comes to an automatic switchover of fan capacity into a higher speed (2. or 3.speed according to the switch setting); see table of steering.

LS-XA, Digitron-WA is equiped, compared to LS-X, with a switch ON/OFF door contact (DK) - changeover to manual operation.

Digitron-WA - this controller is suitable first of all for representativ areas event. sophisticated interiors. The operation is done over an open foil steering keyboard. In case,that the air curtain is connected with a room thermostat (PT), then the room thermostatoperates the fan or in case thermo-electric valve equipage the room thermostat operates the thermo-valve of the air curtain.

Attention:with chaining possibility of the air curtains to one controller

● - series possible; — - impossible

LS+ LS - X

Digitron W Digitron WA

Page 8: 29Li-3_4-A

CCOMFORTOMFORT AIRAIR CURTCURTAINAIN DOORSDOORS TYPETYPE „L„LII3,3, 44““

Stavoklima v. o. s.HORNÍ 22 • CZ - 370 04 ČESKÉ BUDĚJOVICEtel.: +420 387428 990, +420 387438 912fax: +420 387423 610E-mail: [email protected] http://www.stavoklima.cz

Representation:

cooled air

heated aircold winter air

odour, dust filtered air

hot summer air

Type

Air

curt

ain

door

asse

mbly

Hea

ter

type

Air

curt

ain

le

ng

ht

Air

curt

ain

door

types

Order key:

En

gin

ety

pe

Mod

el

VC - vertical air curtain doorHC -horizontal air curtain door

P - right-side furnishingof the heater(suction side view)

L - left-side furnishingof the heater(suction side view)

150 - air curtain length 1500 mm200 - air curtain length 2000 mm250 - air curtain length 2500 mm300 - standard length, (150+150)...... - standard length, (..... + .....)(XX0 - see air curtain types page 7)

S - cold air typeT - hot air type (hot water heater, electric heater)

(on demand other heater types are possible - steam...)

3 - engine revolution 0 -3

T - HC - P - 200 - 3 - Li 3V

„L i“ - model „L i“

Li3V - capacity level 5;water max. 90°C;standard heater; recommended mounting height 4,2m

Li3N - capacity level 5;water max. 90°C;heater for low-temperature gradients; recommended mounting height 4,2 m

Li4V - capacity level 6;water max. 90°C;standard heater; recommended mounting height 4,8m

Li4N - capacity level 6;water max. 90°C;heater for low-temperature gradients; recommended mounting height 4,8 m

Li4NN - capacity level 6;water max. 90°C;heater for extra low-temperature gradients; recommended mounting height 4,8m

Order key

Accessories◆ ceiling-suspended base◆ wall-suspended base

◆ thermostatic valve with capillary sensor◆ door contact◆ operating device

◆ antifrost thermostat◆ accessories for underview air curtains

Air curtains type „Li 3, 4“