100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve,...

7
24" WATER MAIN SEE PROFILE FOR DEPTH FINISHED GRADE L C 36" 12" ELEVATION 48" 12" FINISH GRADE PLAN VIEW 4' PRECAST FOOTING 8' 4' 3" 4" 3" CONCRETE FOOTING LIFT RING 12" 3" R. #4 16" 12" 3" 12" SECTION PLAN 12" 12" #6 12" 8' CONCRETE RINGS TO GRADE (12" MAX) PRECAST CONCRETE FLAT MH TOP (ASTM C-478) PRECAST CONCRETE MH SECTION (ASTM C-478) 12"x12"x8' CONCRETE FOOTING. SEE DETAIL, THIS SHEET. 1 1 2 " ROCK WATERMAIN STEPS @ 12" O.C. 12" MIN. 24" MAX 30" CAST IRON MH FRAME AND COVER 3-#6 CONT. WITH #4 TIE @ 18" LIFT RINGS (TYP.) NOTES: 1. 1 1 2 " ROCK SHALL BE PLACED IN BOTTOM OF MH TO CROWN OF PIPE ONLY. 2. ALL CONNECTION PIPE AND FITTINGS SHALL BE BRASS. 3. SIZE TO MATCH INLET SIZE OF AIR VALVE. 4. SIZE TO MATCH OUTLET OF AIR VALVE. 5. MAKE ALL THREADED PIPE CONNECTIONS USING TEFLON JOINT WRAP. 6. ALL INTERIOR AND EXPOSED METAL SURFACES TO BE PAINTED TO PREVENT CORROSION. 7. LOCATION OF VAULT AND VENT TO BE COORDINATED WITH CONTRACTING OFFICER. AIR RELIEF VALVE ASSEMBLY MANHOLE AIR VENT AND PIPING. SEE NOTE 7 BREAKAWAY COUPLING CONCRETE PAD 1 1 2 " ROCK BEDDING INSIDE OF STRUCTURE 4" GALVANIZED STEEL PIPE, SCHED. 40 4"Ø GALVANIZED STEEL 90° BEND (THREADED) POLYWRAP VENT PIPE UNDERGROUND INSECT SCREEN WELD TO OUTLET STD GALV STEEL COUPLING GROUT GALVANIZED STEEL VENT PIPE SQUARE CUT ALL CORNERS FINISH GRADE 2'x2' SQUARE CONC. COLLAR SINGLE LAYER BOND BREAK ALL AROUND NOTES: 1. MOUND CONCRETE AROUND PIPE TO PROVIDE DRAINAGE. 2. TROWEL FINISH ALL EXPOSED CONCRETE SURFACES. 1" 8" 2" 4" 3/16" 3/16" 4x4 STEEL REINFORCED WIRE MESH NPT GALVANIZED STEEL NIPPLE (TYP.), NOTE 3 NPT BALL VALVE, NOTE 3 DOUBLE STRAP BRASS SADDLE TAP, NOTE 3 NPT GALVANIZED STEEL 90° ELBOW (TYP.), NOTE 4 NPT NIPPLE, NOTE 3 4" COMBINATION AIR RELEASE/VACUUM VALVE, WITH 1 1/6" AIR RELEASE SEE SPECS 60° ALLTHREAD SS ANCHOR BOLTS OR ADHESIVE ANCHORS 1" NONSHRINK GROUT PIPE IN OPEN FIELD IN EXISTING ROAD FINISHED GRADE 24" UTILITY MARKER TAPE 8" LIFTS MAX COMPACTED BACKFILL WIDTH PIPE ZONE, SEE NOTE 4 SEE NOTES 1,2 & 3 6" 6" 5' MIN NEW ROAD SURFACE TO MATCH EXISTING SEE DRAWINGS FOR REPLACEMENT TRACER WIRE 6" 10" 1'-6" 1'-10" 2'-0" 2'-4" PIPE DIAMETER MINIMUM WIDTH MAXIMUM WIDTH TRENCH ZONE 12" 2'-0" 2'-6" 1 CU516 CU516 3 CU516 CU516 CONCRETE FOOTING 100% FOR CONSTRUCTION MANHOLE DETAIL FOR AIR AND VACUUM VALVE NOT TO SCALE 1 CU507 CU507 AIR AND VACUUM VALVE NOT TO SCALE 2 CU507 CU507 BREAK-AWAY COUPLING NOT TO SCALE 3 CU507 CU507 ADJUSTABLE PIPE SUPPORT NOT TO SCALE 7 CU507 CU507 TYPICAL TRENCH SECTION NOT TO SCALE 4 CU507 CU507 GATE VALVE DETAIL 6 CU507 CU507 NOT TO SCALE CONC PAD 5 CU507 CU507 PIPE GATE VALVE, FLANGED VALVE BOX W/ 2" SQUARE NUT VALVE OPERATOR CONCRETE PAD DETAIL 5 CU507 CU507 NOT TO SCALE GATE STEM W/ 2" SQUARE NUT SLOPE TO DRAIN 5'Ø CONCRETE PAD FLUSH MOUNTED VALVE BOX SLOPE TO DRAIN #4 @ 12" OC EW 12" 1 CU508 CU507 1 CU507 CU507 NOTES: 1. IF UNSTABLE MATERIALS ARE FOUND IN TRENCH BOTTOM, OVER EXCAVATE AND PLACE 1 1/2" STABILIZATION ROCK TO REQUIRED DEPTH FOR STABLE TRENCH BOTTOM. PLACE 12 MIL POLYETHYLENE BETWEEN ROCK AND BEDDING MATERIAL. 2. TRENCH TO BE BRACED OR SHEETED AS NECESSARY FOR THE SAFETY OF THE WORKMEN AND THE PROTECTION OF OTHER UTILITIES IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL SAFETY REGULATIONS. 3. FOR PIPE ZONE BEDDING MATERIAL, SEE SPECS. Sheet ID Sheet Designer: Reviewer: File Name: Drafter Submitter: Drawing Date: AFA Project Mgr: A-E Project Mgr: Symb Revisions/Addenda Date Appr Scale: 1OTH CIVIL ENGINEER SQUADRON U.S. AIR FORCE ACADEMY, COLORADO 2315 BRIARGATE PARKWAY, SUITE 150 COLORADO SPRINGS COLORADO 80920 STADIUM BOULEVARD WATERLINE REPLACEMENT XQPZ 06-2002 24 FEB 14 M. ESSIGMANN 06-2002^10470^CU507WDC1.dwg N. WALKER N/A S. REISH J. COOK D.NEILL E. L0WELL WATERLINE DETAILS, 1 OF 4

Transcript of 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve,...

Page 1: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

24"

WATER MAIN

SEE

PR

OFI

LE F

OR

DEP

TH

FINISHED GRADE

LC

36"

12"

ELEVATION

48"

12"

FINISH GRADE

PLAN VIEW

4'

PRECAST FOOTING

8'

4'3"

4"

3"

CONCRETE FOOTING

LIFT RING12"

3" R.

#4

16"

12" 3"

12"

SECTION

PLAN

12"

12"

#6

12"

8'

CONCRETE RINGS TOGRADE (12" MAX)PRECAST CONCRETE FLATMH TOP (ASTM C-478)

PRECAST CONCRETE MHSECTION (ASTM C-478)

12"x12"x8' CONCRETEFOOTING. SEE DETAIL,THIS SHEET.

112" ROCKWATERMAIN

STEPS @ 12" O.C.

12" MIN.24" MAX

30" CAST IRON MH FRAMEAND COVER

3-#6 CONT. WITH #4TIE @ 18"

LIFT RINGS (TYP.)

NOTES:1. 11

2" ROCK SHALL BE PLACED IN BOTTOM OF MH TO CROWN OF PIPE ONLY.

2. ALL CONNECTION PIPE AND FITTINGS SHALL BE BRASS.

3. SIZE TO MATCH INLET SIZE OF AIR VALVE.

4. SIZE TO MATCH OUTLET OF AIR VALVE.

5. MAKE ALL THREADED PIPE CONNECTIONS USING TEFLON JOINT WRAP.

6. ALL INTERIOR AND EXPOSED METAL SURFACES TO BE PAINTED TO PREVENTCORROSION.

7. LOCATION OF VAULT AND VENT TO BE COORDINATED WITH CONTRACTING OFFICER.

AIR RELIEF VALVEASSEMBLY MANHOLE

AIR VENT AND PIPING.SEE NOTE 7

BREAKAWAYCOUPLING

CONCRETE PAD

112" ROCK BEDDING

INSIDE OF STRUCTURE

4" GALVANIZED STEELPIPE, SCHED. 40

4"Ø GALVANIZED STEEL90° BEND (THREADED)

POLYWRAP VENT PIPEUNDERGROUND

INSECT SCREENWELD TO OUTLET

STD GALV STEELCOUPLING

GROUT

GALVANIZEDSTEEL VENTPIPE

SQUARE CUTALL CORNERS

FINISH GRADE

2'x2' SQUARE CONC. COLLAR

SINGLE LAYERBOND BREAK ALLAROUND

NOTES:1. MOUND CONCRETE AROUND PIPE TO PROVIDE DRAINAGE.

2. TROWEL FINISH ALL EXPOSED CONCRETE SURFACES.

1"

8"

2"

4"

3/16"

3/16

"

4x4 STEEL REINFORCEDWIRE MESH

NPT GALVANIZED STEELNIPPLE (TYP.), NOTE 3

NPT BALL VALVE,NOTE 3

DOUBLE STRAP BRASSSADDLE TAP, NOTE 3

NPT GALVANIZED STEEL 90°ELBOW (TYP.), NOTE 4

NPT NIPPLE, NOTE 3

4" COMBINATION AIRRELEASE/VACUUMVALVE, WITH 1 1/6" AIRRELEASE SEE SPECS

60°

ALLTHREAD

SS ANCHOR BOLTS ORADHESIVE ANCHORS

1" NONSHRINKGROUT

PIPE

IN OPEN FIELD IN EXISTING ROAD

FINISHED GRADE

24"UTILITY

MARKERTAPE

8" LIFTS MAXCOMPACTED BACKFILL

WIDTH

PIPE ZONE,SEE NOTE 4

SEE NOTES 1,2 & 3

6"

6"

5' MIN

NEW ROAD SURFACE TO MATCH EXISTINGSEE DRAWINGS FOR REPLACEMENT

TRACER WIRE

6"10"

1'-6"1'-10"

2'-0"2'-4"

PIPEDIAMETER

MINIMUMWIDTH

MAXIMUMWIDTH

TRENCH ZONE

12" 2'-0" 2'-6"

1CU516CU516

3CU516CU516

CONCRETE FOOTING

100% FORCONSTRUCTION

MANHOLE DETAIL FOR AIRAND VACUUM VALVENOT TO SCALE

1CU507CU507

AIR AND VACUUM VALVENOT TO SCALE

2CU507CU507

BREAK-AWAY COUPLINGNOT TO SCALE

3CU507CU507

ADJUSTABLE PIPE SUPPORTNOT TO SCALE

7CU507CU507

TYPICAL TRENCH SECTIONNOT TO SCALE

4CU507CU507

GATE VALVE DETAIL6CU507CU507 NOT TO SCALE

CONC PAD5

CU507CU507

PIPE

GATE VALVE,FLANGED

VALVE BOX W/ 2"SQUARE NUT

VALVE OPERATOR CONCRETE PAD DETAIL5CU507CU507 NOT TO SCALE

GATE STEM W/ 2"SQUARE NUT

SLOPE TO DRAIN

5'Ø CONCRETE PAD

FLUSH MOUNTEDVALVE BOX

SLOPE TO DRAIN

#4 @ 12" OC EW

12"

1CU508CU507

1CU507CU507

NOTES:1. IF UNSTABLE MATERIALS ARE FOUND IN TRENCH BOTTOM, OVER EXCAVATE AND PLACE 1 1/2" STABILIZATION ROCK

TO REQUIRED DEPTH FOR STABLE TRENCH BOTTOM. PLACE 12 MIL POLYETHYLENE BETWEEN ROCK AND BEDDINGMATERIAL.

2. TRENCH TO BE BRACED OR SHEETED AS NECESSARY FOR THE SAFETY OF THE WORKMEN AND THE PROTECTIONOF OTHER UTILITIES IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL SAFETY REGULATIONS.

3. FOR PIPE ZONE BEDDING MATERIAL, SEE SPECS.

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

U50

7WD

C1.

dwg

N. W

ALK

ER

N/A

S. R

EISH

J. C

OO

K

D.N

EIL

L

E. L

0WE

LL

WAT

ERLI

NE

DET

AILS

, 1 O

F 4

Page 2: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

USE CURB STOP BOXES MUELLER H-10300SERIES, FOR TRACER WIRE ACCESS POINTS (TYP)

SET TRACER WIRE TERMINATION BOX 1'-0"OFF EDGE OF SHOULDER AT 1000'

INTERVALS, AND AT PIPE ENDS.COORDINATE WITH CONTRACTING OFFICER

COIL 2' OF WIRE WITHIN LINE VALVE BOX

RUN TRACER WIRE TO EDGE OF SHOULDER

COPPER WIRE MUST BETAPED TO TOP OF PIPEEVERY 3 TO 4 FT

THERMOWELD OR USEA NO.12 COPPER

CONNECTOR(SEE DETAIL ATHIS SHEET)

USE NO. 12 THIN SOLID COPPER, DIRECTBURY, JACKETED TRACER WIRE

WIRE TO BE TAPEDON EACH SIDE OFEVERY JOINT

THERMOWELD, OR USE A NO. 12 COPPERCONNECTOR (SEE DETAIL B THIS SHEETFOR TEE). ALL CONNECTIONS SHALL BESHRINK WRAPPED AND TAPED WITHELECTRICAL TAPE.

DETAIL A

DETAIL B

12"x12"x6" CONCRETE COLLAR

EXISTING 6" CIP

CONNECT TO EXISTING 6" CIP WATERLINEWITH 6" HDPE 45° BEND, THRUSTBLOCK

AND 6" HDPE x 6" CIP COUPLING

10" GATE VALVE

10" x 8" HDPE REDUCERAND 8" x 6" HDPE REDUCER

W

W

W

W W W

EXISTING6" GATE VALVE

EXISTINGTEE

10"X8" REDUCERAND

8"X6" REDUCER

NEW 10"HDPE

NEW HDPE 45° BEND

EXISTINGBACK FLOWPREVENTOR

REMOVE EXISTING SPOOL PIECEAND COUPLING AND CONNECT TOEXISTING WITH 6" HDPE X 6" DIPCOUPLING

11.25° BENDPLAN

WID

TH(w

.11.

25_d

iam

eter

)

LENGTH(l.11.25_diameter)

WID

TH(w

.45_

diam

eter

)

LENGTH(l.45_diameter)

WID

TH(w

.Tee

_dia

met

er)

LENGTH(l.Tee_diameter)

22.5° BENDPLAN

45° BENDPLAN

TEEPLAN

Flow Flow

Flow

MIN

IMU

M S

OIL

CO

VER

LENGTH

WID

TH(w

.22.

5_di

amet

er)

LENGTH(l.22.5_diameter)

Flow

HE

IGH

T

SECTION

GENERAL NOTES:1. USE MINIMUM 3500 PSI CONCRETE.2. DESIGN PRESSURE IS 200 psi

MAXIMUM ALLOWABLE PRESSURE.3. REINFORCE THRUST BLOCKS W/ #6

BARS @ 10" ON CENTER EACH WAYEACH FACE, MINIMUM (2) BARSEACH WAY EACH FACE.

4. PIPE MAY BE C900/C905 PVC OR DIPWITH A MINIMUM OF 5'-0" OF SOILABOVE THE TOP OF THE PIPE.

5. ALL BENDS ARE HORIZONTAL.UPWARD BENDS NOT PERMITTEDBASED ON THIS TABLE.

12"MIN

18"

MAX

VARIES

8"

5" MIN

12"

PRECAST CONC SLAB

XXXX

VARIES

CONC EXTENSION COLLARS

30" CAST IRON MHFRAME AND COVER

TOP SECT OF 6" VB(EXTENSION IF REQD) HOLE IN

MH FLAT TOP COVERTO BE DRILLED IN FIELD

VALVE OPERATOR TO BEACCESSIBLE THRU VB

OPENINGGROUND LINE VALVE BOX

SUPPORT PLATE

5'-0"Ø PRECAST CONCFLAT MH COVER

(ASTM C 478)

5'-0" Ø PRECAST CONC MH SECTW/ RUNGS (ASTM C 478)

NPW

6" DI MJ45° BEND

MASTICAROUND SPIGOT,

OPENING TO BEPRECAST

5"Ø HOLE

OPERATOREXT

OPERATOREXT GUIDEAPPD MASTIC

(TYP)

6" FLGGV

6"Ø 90°ELB UP

STD ADJSPRT

2'x 6" DIFLG xSPIGOT

WWF4x4-W4xW4

6"

6'-0" SQ

INSTALL PIPE SPOOL THAT EXTENDSTO TOP OF PIPE ELEVATION

6" FLG

6" FLG

HEIGHT WIDTH LENGTH

6" PIPE

11.25° BEND 12 IN 12 IN 12 IN22.5° BEND 14 IN 12 IN 16 IN45° BEND 18 IN 12 IN 24 IN90° & TEE'S 24 IN 12 IN 24 IN

10" PIPE

11.25° BEND 18 IN 16 IN 18 IN22.5° BEND 24 IN 20 IN 24 IN45° BEND 34 IN 22 IN 34 IN90° & TEE'S 40 IN 22 IN 40 IN

12" PIPE

11.25° BEND 20 IN 18 IN 20 IN22.5° BEND 28 IN 18 IN 30 IN45° BEND 38 IN 20 IN 40 IN90° & TEE'S 46 IN 24 IN 46 IN

W 6" HDPE 45° BENDWITH THRUSTBLOCK

CUT AND CAPEXISTING 6" CIP

CUT AND REMOVEEXISTING 6" CIP

10" HDPE WATERLINE

6" HDPE WATERLINE

5.0'

EXISTING 6" CIP

EXISTING 10" CIP(ABANDON)

CUT AND CAPEXISTING 10" CIP

100% FORCONSTRUCTION

COPPER TRACER WIRENOT TO SCALE

1CU508CU508

TRANSMISSION MAIN BLOWOFF INSTALLATIONNOT TO SCALE

2CU508CU508

WWTP NORTH TIE-IN DETAILNOT TO SCALE

3CU106CU508

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

U50

8WD

C2.

dwg

N. W

ALK

ER

N/A

S. R

EISH

J. C

OO

K

D.N

EIL

L

E. L

0WE

LL

WAT

ERLI

NE

DET

AILS

, 2 O

F 4

5CU508CU508

WWTP EAST TIE-IN DETAILNOT TO SCALE

4CU106CU508

CONCRETE THRUST BLOCK DETAILNOT TO SCALE

5CU106CU508

5CU508CU508

Page 3: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

PLAN

ELEVATION

12" O.D. PIPE (TYP)

CONCRETEBLOCK

APPROVED MJRSNT (TYP)

APPROVED MJRSNT (TYP)

CONCRETE BLOCKW/#6 REBAR @ 12" O.C.

FLOW

DIT

CH

ED

GE

DIT

CH

ED

GE

DIT

CH

ED

GE

DIT

CH

ED

GE

3'-0"

3'-0"

POUR INTO SOLID BANK OF TRENCHNOT LESS THAN 3'-0" (TYP)

TRENCH WIDTH

APPROVED MJRSNT (TYP)

"A"

'A' MEASUREMENTS:12" & UNDER = 2'-0"

OVER 12" = 3'-0"

30" RCP AND SMALLER-UTILITY STRUCTURE

BEND

BEND

5' MIN.

ELEVATION:

BEND

BEND

PLAN:

SOIL TO BECOMPACTED AROUND

PIPE. (REF: SECTION 2)

UTILITY, STORM SEWER ORDRAINAGE STRUCTURE. ( 30"RCP AND SMALLER )

EXIST./PROPOSEDWATER LINE

NOTES:

1. LOWERINGS TO BE CATHODIC PROTECTED UNDER THEDIRECTION OF THE CONTRACTING OFFICER.

2. ALL FITTINGS SHALL BE BUTTWELDED UNLESS APPROVEDOTHERWISE BY CONTRACTING OFFICER.

3. EXAMPLE CAN VARY DUE TO SITE CONDITIONS ANDCONTRACTING OFFICER'S DECISIONS.

5' MIN.

18" MIN.SEPARATION

PROPOSED WATERLINE

100% FORCONSTRUCTION

LOWERING DETAILNOT TO SCALE

1CU509CU509

ANCHOR BLOCK DETAILNOT TO SCALE

2CU509CU509

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

U50

9WD

C3.

dwg

N. W

ALK

ER

N/A

S. R

EISH

J. C

OO

K

D.N

EIL

L

E. L

0WE

LL

WAT

ERLI

NE

DET

AILS

, 3 O

F 4

Page 4: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

SECTION A-A

AELEVATION

ATOP OF GROUND

NORMAL PIPETRENCH DEPTH18" BELOW PIPE

3' - 4'ABOVE GROUND

WIRING C,D(BLACK)

WIRING B(BLUE)

WIRING A(BLUE)

3" THICK X 12" SQUARECONCRETE PAD

CATHODIC PROTECTION TEST STATIONBRANCE/KRACHY & CO OR EQUAL

METALFITTING

HDPEWATERLINE

9LB HIGH-POTENTIALMAGNESIUM ANODE

TEST STATIONTERMINAL BOARD

WIRING DETAIL

MOUNTING STUD(TYP)

A B C D

12"

18" BELOW PIPE

100% FORCONSTRUCTION

INSTALLATION OF CATHODICPROTECTION TEST STATIONNOT TO SCALE

1CU510CU510

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

U51

0WD

C4.

dwg

N. W

ALK

ER

N/A

S. R

EISH

J. C

OO

K

D.N

EIL

L

E. L

0WE

LL

WAT

ERLI

NE

DET

AILS

, 4 O

F 4

NOTES1. ALL FITTINGS AND APPURTENANCES SHALL BE ENCASED IN POLYETHYLENE

WRAPPING AND TIGHTLY TAPED AGAINST THE PIPE AT A MINIMUM DISTANCEOF ONE (1) FOOT ON EACH SIDE OF THE FITTING OR APPURTENANCE, WITHTHE EXCEPTION THAT ENCASEMENT ON HYDRANT BARRELS WILL BETERMINATED NEAR GROUND LINE.

2. ALL TIE RODS WILL BE PROTECTED FROM CORROSION BY ENCASING THEMIN A 3 INCH POLY ETHYLENE WRAP AND SECURING WITH TAPE, EXCEPTWHERE THE RODS ARE IN CONTACT WITH CONCRETE, IN WHICH CASE ITMUST BE COATED. ALL MECHANICAL JOINT FITTINGS TIED BACK WITH RODSSHALL BE WRAPPED IN POLYETHYLENE TO PROTECT THAT PORTION OF THETIE ROD WHICH EXTENDS THROUGH THE FLANGE.

3. ALL METAL FITTINGS AND APPURTENANCES SHALL BE INSTALLED WITH ONE(1) NINE POUND (9 LB) HIGH POTENTIAL MAGNESIUM ANODE BONDED TO THEMETAL. ONE (1) ANODE FOR EACH INDIVIDUAL FITTING OR APPURTENANCESHALL BE REQUIRED. UP TO THREE FITTINGS MAY BE GROUPED TOGETHERWITH A SINGLE ANODE. ALL ANODES SHALL BE FURNISHED AND INSTALLEDBY THE CONTRACTOR.

4. INSTALL TEST STATIONS WHERE SHOWN ON THE DRAWINGS. TEST STATIONLOCATION MAY VARY DUE TO SITE CONDITIONS AND CONTRACTINGOFFICER DIRECTIONS.

5. ALL MAGNESIUM, SACRIFICIAL ANODES WILL COMPLY WITH THEREQUIREMENTS OF THE CODE OF FEDERAL REGULATIONS TITLE 49, U.S.DEPARTMENT OF TRANSPORTATION, PART 192.

6. ALL ANODES WILL BE BAGGED. BAGGED ANODES WILL BE PACKAGED INCLOSELY WOVEN, PERMEABLE, CLOTH WITH AT LEAST ONE INCH OF WELLCOMPACTED BACKFILL.

7. THE BACKFILL PARTICLE SIZE WILL BE 15% MAXIMUM RETENTION BYWEIGHT ON A 20-MESH SCREEN AND 75% MAXIMUM RETENTION BY WEIGHTON A 100-MESH SCREEN.

8. ANODES TO BE INSTALLED A MINIMUM OF 15 FOOT DISTANCE AWAY FROMANY FOREIGN METALLIC NATURAL GAS LINE OR WATERLINE CROSSINGS.

9. LEAD WIRES SHALL BE EXOTHERMAL (CADWELD) WELDED TO METALFITTINGS IN ACCORDANCE WITH THE INSTRUCTIONS OF THE WELDINGEQUIPMENT MANUFACTURER. REMOVE A SMALL PORTION OF COATING ASNECESSARY FOR WELD. REPAIR COATING PER SPECIFICATIONS.

10. ALL LEADS ENTERING TEST STATIONS WILL HAVE SUFFICIENT COILEDSLACK TO FACILITATE COVER REMOVAL FOR TESTING.

11. AVOID ELECTRICAL CONTACT BETWEEN PROTECTED STRUCTURE ANDSTRUCTURAL REBAR, CONDUITS AND OTHER FOREIGN METALLICSTRUCTURES.

12. INSULATING FLANGE KITS, DIELECTRIC UNIONS OR OTHER PIPELINEINSULATORS SHALL BE INSTALLED WHERE NEW METALLIC FITTINGS ARECONNECTED INTO EXISTING WATER AND GAS LINES THAT ARE METALLIC.WHERE INSULATORS ARE INSTALLED UNDERGROUND, INSTALL TWO (2)ADDITIONAL #12 LEADS TO THE EXISTING METALLIC LINES. THEINSTALLATION CONTRACTOR IS RESPONSIBLE FOR KEEPING A LOG OF ALLANODES AND TEST STATIONS WITH THEIR DIMENSIONED LOCATIONS. LOGWILL BE SUBMITTED TO CONTRACTING OFFICER WITH RECORD DRAWINGS.

13. INSTALLATION CONTRACTOR SHALL COORDINATE CONSTRUCTION WITHCONTRACTING OFFICER SUCH THAT TESTING AND INSPECTION CAN BECONVENIENTLY COMPLETED.

14. NO SOIL SAMPLES HAVE BEEN ANALYZED. THE PROVIDED CORROSIONPROTECTION DESIGN FOR METAL FITTINGS ASSUMES A 20 YEAR DESIGNLIFE IN HIGHLY CORROSIVE SOILS.

Page 5: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

W

W

WW

28+0030+00

32+00

34+0036+00 38+00

SF

SF

SF SF

0+002+00

4+00

6+006+03

0+002+00

4+00

5+75

SFSF

SF SFSF SF SF SF SF SF

100% FORCONSTRUCTION

NOTES:

1. ALL DISTURBED AREAS REQUIRE RESEEDINGAND SHALL BE RECLAIMED AND RESTORED PERTHE PROJECT SPECIFICATIONS.

LEGENDLIMITS OF DISTURBANCE

CHECK DAMS

SILT FENCE

VEHICLE TRACKING CONTROL

SF SF

CONCRETE WASHOUT AREA

STABILIZED STAGING AREA

DRAINAGE FLOW DIRECTION

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

G11

1ESC

C.d

wg

N. W

ALK

ER

1"=1

00'-0

"

S. R

EISH

J. C

OO

K

D.N

EIL

L

E. L

0WE

LL

ER

OS

ION

& S

ED

IME

NT

CO

NTR

OL

PLAN

12" HDPE WATERLINE

10" HDPEWATERLINE

10" HDPEWATERLINE

Page 6: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

100% FORCONSTRUCTION

GRADING AND EROSION CONTROL GENERAL NOTES

1. ALL DISTURBED AREAS SHALL BE REVEGETATED USING THE SEEDING MIX SHOWN IN THESPECIFICATIONS.

2. THE CONTRACTOR SHALL HAVE AT LEAST ONE (1) SIGNED COPY OF THESE APPROVED PLANS AND ATLEAST ONE (1) COPY OF THE APPROPRIATE DESIGN AND CONSTRUCTION STANDARDS ANDSPECIFICATIONS AT THE JOB SITE OR AT THEIR OFFICE AT ALL TIMES. MANUALS SHALL INCLUDE, BUT NOTBE LIMITED TO, THE FOLLOWING:

A. CITY OF COLORADO SPRINGS/EL PASO COUNTY DRAINAGE CRITERIA MANUAL, VOLUMES 1 AND 2

3. INITIAL EROSION CONTROL MEASURES ARE TO BE IN PLACE PRIOR TO MOVEMENT OF ANY DIRT IN THEPROPOSED DISTURBED AREAS.

4. EROSION AND SEDIMENT CONTROLS:

INITIAL: PRIOR TO CONSTRUCTION ON PORTIONS OF THIS SITE, INITIAL BMP'S INCLUDING BUT NOT LIMITEDTO SILT FENCE, SHALL BE INSTALLED ALONG THE SECTION OF WATERMAIN TO BE CONSTRUCTED.

CONSTRUCTION: EROSION CONTROL MEASURES SHALL BE IMPLEMENTED IN A MANNER THAT WILLPROTECT ADJACENT PROPERTIES AND PUBLIC FACILITIES FROM ADVERSE EFFECTS OF EROSION ANDSEDIMENTATION AS A RESULT OF CONSTRUCTION AND EARTHWORK ACTIVITIES WITHIN THE PROJECT SITE.

PERMANENT: PERMANENT BMP'S INCLUDING BUT NOT LIMITED TO SEEDING, WADDLES AND SHALL BECONSTRUCTED AFTER CONSTRUCTION IS DONE AND CONSTRUCTION BMP'S ARE IN PLACE, OR AS NEEDEDBASED ON THE PHASING OF THE PROJECT.

5. MATERIAL HANDLING AND SPILL PREVENTION:THE MOST PROBABLE SOURCE OF NON-STORMWATER POLLUTION IS REFUELING AND DAILY MAINTENANCEOPERATIONS. IF MOBILE FUEL TRUCKS ARE USED TO SERVICE EQUIPMENT, ABSORBENT MATERIALS ANDCONTAINERS FOR THE STORAGE OF USED ABSORBENT MATERIAL WILL BE CLOSE BY. IF A FUEL TANK ISLEFT ON SITE, BERMS WILL BE BUILT AROUND THE TANK TO CAPTURE ANY SPILLED FUEL.

6. FINAL STABILIZATION AND LONG TERM STORMWATER MANAGEMENT:ONCE THE DISTURBED AREAS ARE 70% ESTABLISHED WITH VEGETATION, THE INLET PROTECTION AND SILTFENCES ON THE SITE MAY BE REMOVED.

7. INSPECTION AND MAINTENANCE:A THOROUGH INSPECTION OF THE STORMWATER MANAGEMENT SYSTEM SHALL BE PERFORMED EVERY 14DAYS AS WELL AS AFTER ANY RAIN OR SNOWMELT EVENT THAT CAUSES SURFACE EROSION.EROSION OF CHANNELS AND SIDE SLOPES SHALL BE REPAIRED. WHEN STRAW BALE CHECK DAMS ORWADDLES HAVE SILTED UP TO HALF THEIR HEIGHT, THE SILT SHALL BE REMOVED, CHANNEL GRADEREESTABLISHED AND SIDE SLOPES RESEEDED IF NECESSARY. ANY STRAW BALES THAT HAVE SHIFTED ORDECAYED SHALL BE REPAIRED OR REPLACED. SILT FENCES SHALL BE CLEANED WHENEVER SEDIMENTHAS REACHED A DEPTH OF 6" AT THE FENCE, AND BROKEN WOODEN PARTS OR TORN FABRIC SHALL BEREPAIRED OR REPLACED. ANY ACCUMULATED TRASH OR DEBRIS SHALL BE REMOVED FROM OUTLETS. ANINSPECTION AND MAINTENANCE LOG FOLLOWS THIS STORMWATER MANAGEMENT PLAN.

8. THE GRADING OF THE DISTURBED AREAS SHALL BE DONE TO MINIMIZE DISTURBED AREAS AS MUCH ASPOSSIBLE PRIOR TO SEEDING/MULCHING.

GRADING AND EROSION CONTROL SPECIFIC NOTES

1. IN AREAS THAT ARE RELATIVELY FLAT, EXISTING GRASS BUFFERS CAN BE USED AS A BMP IN LIEU OFSILT FENCE. REVIEW THESE AREAS ON A CASE BY CASE BASIS.

2. SEE SPECIFICATIONS FOR SILT FENCE AND OTHER BMP INSTALLATION DETAILS

3. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED. SEE SPECIFICATIONS FOR SEEDINGSPECIFICATIONS

SEEPAGE

6" MIN.4" MIN.

TWINE/WIRE

2"X 2" WOOD STAKE

FILTERED

COMPACTED SOIL TOPREVENT PIPING

STAKED AND ENTRENCHEDSTRAW BALE

LINE BALE(S) TO PREVENT GAPS.OVERLAP SIDE BALES ON FLOW

THAN FLOW LINE POINT "B".END POINTS "A" MUST BE HIGHER

CROSS SECTION OF INSTALLED STRAW BALEDITCH EROSION BALES

SEDIMENTLADEN RUNOFF

8.3 FOOT CENTERS

TO UPSTREAM

1. INSPECT AND REPAIR SILT FENCE AFTER EACHSTORM EVENT AND REMOVE SEDIMENT WHEN

2. REMOVED SEDIMENT SHALL BE DEPOSITEDTO AN AREA THAT WILL NOT CONTRIBUTESEDIMENT OFF-SITE AND CAN BE PERMANENTLY

3. SILT FENCE SHALL BE PLACED ON SLOPECONTOURS TO MAXIMIZE PONDING EFFICIENCY.

FENCE IS HALF COVERED.

STABILIZED.

SIDE OF POST.

RUNOFF

4"x6" TRENCHWITH COMPACTEDBACKFILL

UV STABILIZED WOVEN SLIT FILM

WOOD POST

2"x2" WOOD POST4'-6" MIN. LENGTH

GEOTEXTILE WITH TENSIONING BELT

FILTER FABRICATTACH SECURELY

PONDING HT.

FLOW

18"

MIN

.

FLOW

FLOW

NOTES:

SILT FENCE DETAILNOT TO SCALE

1CG512CG512

CHECK DAM DETAILNOT TO SCALE

2CG512CG512

As

Required

DIRT ROAD

6" Minimum

1 1/2" - 3" Rock, 4" Thick1/2" - 3/4" Filter Layer, 2" Thick

50' Minimum

NOTES:1. DIRT ROAD TO BE KEPT CLEAN OF DEBRIS.2. IF A DRAINAGE DITCH EXISTS NEXT TO ROADWAY, INSTALL TEMPORARY CULVERT UNDERNEATH

STONE CONSTRUCTION TO CONVEY FLOW.3. 2" - 3" STONE SHALL CONTAIN LESS THAN 10% FINES.4. CONSTRUCTION EXIT SHALL BE MAINTAINED AT ALL TIMES. STONE SHOULD BE BLADED AND/OR

ADDITIONAL 2" - 3" STONE SHOULD BE PLACED IF VOIDS BEGIN FILLING WITH DEBRIS.5. PROVIDE INLET PROTECTION FOR ANY INLETS LOCATED IMMEDIATELY ADJACENT TO THE

CONSTRUCTION EXIT.

VEHICLE TRACKINGCONTROL DETAILNOT TO SCALE

3CG512CG512

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

G51

2ED

1C.d

wg

N. W

ALK

ER

N/A

S. R

EISH

J. C

OO

K

D.N

EIL

L

E. L

0WE

LL

ER

OS

ION

& S

ED

IMEN

T C

ON

TRO

LD

ETAI

LS, 1

OF

2

Page 7: 100% FOR CONSTRUCTION - BASCO GROUP LLC · 2019-10-27 · conc pad 5 cu507 cu507 pipe gate valve, flanged valve box w/ 2" square nut 5 valve operator concrete pad detail cu507 cu507

100% FORCONSTRUCTION

SheetID

Sheet

Des

igne

r:R

evie

wer

:

File

Nam

e:

Dra

fter

Sub

mitt

er:

Dra

win

g D

ate:

AFA

Pro

ject

Mgr

:A

-E P

roje

ct M

gr:

Sym

bR

evis

ions

/Add

enda

Dat

eA

ppr

Sca

le:

1OTH CIVIL ENGINEER SQUADRONU.S. AIR FORCE ACADEMY, COLORADO

2315 BRIARGATEPARKWAY, SUITE 150COLORADO SPRINGS

COLORADO 80920

ST

AD

IUM

BO

ULE

VA

RD

WA

TE

RLI

NE

RE

PLA

CE

ME

NT

XQ

PZ

06-

2002

24 F

EB

14

M. E

SS

IGM

AN

N

06-2

002^

1047

0^C

G51

3ED

2C.d

wg

N. W

ALK

ER

N/A

S. R

EISH

J. C

OO

K

D. N

EIL

L

E. L

0WE

LL

ER

OS

ION

& S

ED

IMEN

T C

ON

TRO

LD

ETAI

LS, 2

OF

2