UFE treatment: long term follow up of Bead Block registry
Dr Thomas J Kroencke
Department of Radiology,
Charité Berlin, Germany
ET/ECIO Satellite Symposium, Thursday 10 April 2008
2Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
dsBead Block for UFE: 3-year Clinical Follow-up
• Two centre registry*
• Bead Block PVA microspheres for UAE
• Initial Results published in JVIR 2008
• Long-term clinical data from one centre
* Department of Radiology, Charité Medical School, Berlin, Germany
Department of Radiology and Gynecology, St. Elisabeth Ziekenhuis, Tilburg, The Netherlands (Drs. Lohle, Lampman, Boekkoi)
3Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Material and Methods
• Protocol A („limited“)
- start with 500-700 µm APVA
- upsize if endpoint not reached after 6 ml
- size range: 500-1200 µm
- endpoint: limited embolization
• Protocol A („stasis“)
- start with 700-900 µm APVA
- upsize if endpoint not reached after 6 ml
- size range: 500-1200 µm
- endpoint: (near) stasis
4Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Data evaluation
• Quality of Life Changes (UFS-QoL®)
– changes in symptom severity score
– changes in quality of life score
• Patient satisfaction
• Re-interventions / failures
5Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Symptom Severity & QoL per protocol
Significant (p < 0.001) for both protocols JVIR 2008; 19:47-57
6Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Symptom Severity & QoL per protocol
JVIR 2008; 19:47-57 Significant (p < 0.001) for both protocols
7Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Imaging Results
Kroencke et al., J Vasc Interv Radiol 2008; 19:47-57
8Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Limitations
limited protocol
N= 13/18
N=4/13
N=6/14
stasis protocol
N=14/20
Menopausal @ 35 months
Menorrhagia:3/4
Dominant symptom
Menorrhagia:3/6
9Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Clinical Results
limited protocol
N=18
N=13
N=14*
stasis protocol
N=20
Available@
36 months
Symtom Severity Score:
42 >> 13 HRQL Score
66 >> 98
UFS-QOL
Score
re-intervention
N=2 hysterectomy
(N=1 hyster.resec.
& myomectomy)
re-intervention
N = 4 Re-UAEN = 1 HE
Symtom Severity Score:
53 >> 19 HRQL Score
59 >> 87
Within 2Yfollow-up;
None thereafter!
* N = 3 lost to follow-up
UFS-QOL: uterine fibroid symptom and quality of life questionaire
UAE: uterine artery embolisation
10Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Patient Satisfaction
• Protocol A („limited“)
– very satisfied 9/13
– satisfied 3/13
– not sure -
– not satisfied 1/13
• Protocol A („stasis“)
– very satisfied 4/14
– satisfied 8/14
– not sure 1/14
– not satisfied 1/14
11Infa
rctio
n E
nd P
oint
in B
land
Em
bolis
atio
n an
d D
rug-
Elu
ting
Bea
ds
Conclusion
• APVA microspheres, Bead Block®, are an effective embolic agent for UAE with favorable clinical results at 3-year follow-up
• 700-900 µm spheres and stasis as the embolisation endpoint resulted in fewer re-interventions as compared to limited embolisation with use of 500-700 µm spheres