085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV...

55
No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:[email protected] http://www.quietek.com CERTIFICATE Issued Date: June 23, 2008 Report No.: 085285R-ITUSP02V01 This is to certify that the following designated product Product : GV-Access Control System Trade name : Model Number : GV-AS200-4E V2, GV-AS200-2CE, GV-AS200 EXIO Board V1, GV-AS KeyPad V1, GV-Battery V1, GV-USB DONGLE, GV-Joystick V1, GV-Keyboard V2 Company Name : GeoVision Inc. This product, which has been issued the test report listed as above in QuieTek Laboratory, is based on a single evaluation of one sample and confirmed to comply with the requirements of the following EMC standard. FCC CFR Title 47 Part 15 Subpart B: 2007 Class A, CISPR 22: 2005 ANSI C63.4: 2003 ICES-003 Issue 4: 2004 Class A TEST LABORATORY Vincent Lin / Deputy Manager

Transcript of 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV...

Page 1: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kou Shiang, Taipei 244 Taiwan, R.O.C. TEL:+886-2-8601-3788 FAX:+886-2-8601-3789 Email:[email protected] http://www.quietek.com

CERTIFICATE

Issued Date: June 23, 2008 Report No.: 085285R-ITUSP02V01

This is to certify that the following designated product

Product : GV-Access Control System

Trade name : Model Number : GV-AS200-4E V2, GV-AS200-2CE, GV-AS200 EXIO Board

V1, GV-AS KeyPad V1, GV-Battery V1, GV-USB DONGLE,

GV-Joystick V1, GV-Keyboard V2

Company Name : GeoVision Inc.

This product, which has been issued the test report listed as above in QuieTek

Laboratory, is based on a single evaluation of one sample and confirmed to

comply with the requirements of the following EMC standard.

FCC CFR Title 47 Part 15 Subpart B: 2007 Class A, CISPR 22: 2005

ANSI C63.4: 2003 ICES-003 Issue 4: 2004 Class A

TEST LABORATORY

Vincent Lin / Deputy Manager

Page 2: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Test Report Compliance with Industry Canada Interference-Causing

Equipment Standard ICES-003 Product Name : GV-Access Control System

Model No. : GV-AS200-4E V2, GV-AS200-2CE, GV-AS200 EXIO Board V1, GV-AS KeyPad V1, GV-Battery V1, GV-USB DONGLE, GV-Joystick V1, GV-Keyboard V2

Applicant : GeoVision Inc.

Address : 9F., No.246, Sec. 1, Neihu Rd., Neihu District, Taipei

114, Taiwan R.O.C.

Date of Receipt : 2008/05/19

Issued Date : 2008/06/23

Report No. : 085285R-ITUSP02V01

Version : V0.1-Draft

The test results relate only to the samples tested.The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by TAF, NVLAP, NIST or any agency of the Government. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.

Page 3: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

DECLARATION OF CONFORMITY Per FCC Part 2 Section 2. 1077(a)

The following equipment:

Product Name : GV-Access Control System

Trade Name : Model Number : GV-AS200-4E V2, GV-AS200-2CE, GV-AS200 EXIO Board V1,

GV-AS KeyPad V1, GV-Battery V1, GV-USB DONGLE, GV-Joystick V1, GV-Keyboard V2

It’s herewith confirmed to comply with the requirements of FCC Part 15 Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that

may cause undesired operation.

The result of electromagnetic emission has been evaluated by QuieTek EMC laboratory (NVLAP Lab. Code : 200533-0 ) and showed in the test report. ( Report No. : 085285R-ITUSP02V01 )

It is understood that each unit marketed is identical to the device as tested, and any changes to the device that could adversely affect the emission characteristics will require retest.

The following importer / manufacturer is responsible for this declaration:

Company Name

Company Address

Telephone Facsimile :

Person is responsible for marking this declaration:

Name ( Full name ) Position / Title

Date Legal Signature

Page 4: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 2 of 53 V0.1-Draft

Test Report Cert i f icat ion Issued Date : 2008/06/23 Report No. : 085285R-ITUSP02V01

Product Name : GV-Access Control System Applicant : GeoVision Inc. Address : 9F., No.246, Sec. 1, Neihu Rd., Neihu District, Taipei 114,

Taiwan R.O.C. Manufacturer : GeoVision Inc. Model No. : GV-AS200-4E V2, GV-AS200-2CE, GV-AS200 EXIO Board

V1, GV-AS KeyPad V1, GV-Battery V1, GV-USB DONGLE, GV-Joystick V1, GV-Keyboard V2

Rated Voltage : AC 120 V / 60 Hz EUT Voltage : AC 100-240V, 50/60Hz Trade Name :

Applicable Standard : FCC CFR Title 47 Part 15 Subpart B: 2007 Class A

CISPR 22: 2005, ANSI C63.4: 2003 ICES-003 Issue 4: 2004 Class A

Test Result : Complied Performed Location : Quietek Corporation (Linkou Laboratory)

No.5-22, Ruei-Shu Valley, Ruei-Ping Tsuen Lin Kuo Shiang, Taipei, 244 Taiwan, R.O.C. TEL:+866-2-8601-3788 / FAX:+886-2-8601-3789

Documented By :

(Adm. Specialist /Joanne Lin)

Reviewed By :

(Engineer / Harrison Chen)

Approved By :

( Deputy Manager / Vincent Lin )

Page 5: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 3 of 53 V0.1-Draft

Laboratory Information We , QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted (audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scopes:

The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://tw.quietek.com/modules/enterprise/services.php?item=100 The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory :

No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected]

LinKou Testing Laboratory :

No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]

Suzhou (China) Testing Laboratory :

No. 99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., Suzhou,China.TEL : +86-512-6251-5088 / FAX : +86-512-6251-5098 E-Mail : [email protected]

Taiwan R.O.C. : BSMI, NCC, TAF

Germany : TUV Rheinland

Norway : Nemko, DNV

USA : FCC, NVLAP

Japan : VCCI

Page 6: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 4 of 53 V0.1-Draft

TABLE OF CONTENTS Description Page 1. General Information .................................................................................................... 5 1.1. EUT Description................................................................................................... 5 1.2. Mode of Operation............................................................................................... 6 1.3. Tested System Details ......................................................................................... 7 1.4. Configuration of Tested System........................................................................... 8 1.5. EUT Exercise Software........................................................................................ 9 2. Technical Test ........................................................................................................... 10 2.1. Summary of Test Result..................................................................................... 10 2.2. List of Test Equipment ....................................................................................... 11 2.3. Measurement Uncertainty.................................................................................. 12 2.4. Test Environment ............................................................................................... 13 3. Conducted Emission................................................................................................. 14 3.1. Test Specification............................................................................................... 14 3.2. Test Setup.......................................................................................................... 14 3.3. Limit ................................................................................................................... 14 3.4. Test Procedure .................................................................................................. 15 3.5. Test Result ......................................................................................................... 16 3.6. Test Photograph ................................................................................................ 34 4. Radiated Emission.................................................................................................... 37 4.1. Test Specification............................................................................................... 37 4.2. Test Setup.......................................................................................................... 37 4.3. Limit ................................................................................................................... 38 4.4. Test Procedure .................................................................................................. 39 4.5. Test Result ......................................................................................................... 40 4.6. Test Photograph ................................................................................................ 42 5. Attachment................................................................................................................ 43   EUT Photograph ................................................................................................ 43

Page 7: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 5 of 53 V0.1-Draft

1. General Information

1.1. EUT Description

Product Name GV-Access Control System Trade Name

Model No. GV-AS200-4E V2, GV-AS200-2CE, GV-AS200 EXIO Board V1,

GV-AS KeyPad V1, GV-Battery V1, GV-USB DONGLE, GV-Joystick V1, GV-Keyboard V2

Component Power Adapter (1) MFR: GeoVision, M/N: A2-36SG12R-V

Input: AC 100-240V, 50-60Hz, 1.2A Output: DC 12, 3.0A, 36W Max Cable Out: Non-Shielded, 1.8m

Power Adapter (2) MFR: DVE, M/N: DSA-0131F-12 Input: AC 100-240V, 50-60Hz, 0.3A Output: DC 12, 1A Cable Out: Non-Shielded, 1.8m

Page 8: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 6 of 53 V0.1-Draft

1.2. Mode of Operation QuieTek has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: Pre-Test Mode

Mode 1: Normal Operation

Final Test Mode

Emission Mode 1: Normal Operation

Page 9: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 7 of 53 V0.1-Draft

1.3. Tested System Details The types for all equipments, plus descriptions of all cables used in the tested system (including inserted cards) are:

Product Manufacturer Model No. Serial No. Power Cord

1 Monitor ADI CT1797NF 23500ET112A0021 Non-Shielded, 1.8m

2 PC CPU Intel Intel(R)

Pentium® 4CPU

3.06G

N/A Non-Shielded, 1.8m

M/B ASUS P4GD1 REV1.03 N/A

VGA Card ASUS RV380LE-A334C

REV1.01

N/A

HDD IBM DTLA-305020 N/A

DVD-ROM ASUS CD-S520/A5 N/A

S.P.S SevenTeam ST-460EAD-05F N/A

DDR Twin Mos M2S9108A-PS N/A

3 Walkman AIWA HS-TA164 N/A N/A

4 Microphone &

Earphone

PCHOME N/A N/A N/A

5 Keyboard Acer 6311-TW4C/6 N/A N/A

6 Switch D-Link DES-1005D N/A Non-Shielded, 1.8m

7 Mouse HITACHI PC-KM1300 N/A N/A

8 Door N/A N/A N/A N/A

9 GV-READER GeoVison N/A N/A N/A

Page 10: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 8 of 53 V0.1-Draft

1.4. Configuration of Tested System

Connection Diagram

Signal Cable Type Signal cable Description A LAN Cable Non-Shielded, 7m B LAN Cable Non-Shielded, 7m C LAN Cable Non-Shielded, 7m D D-SUB Cable Shielded, 1.8m, with two ferrite cores bonded. E AUDIO Cable Non-Shielded, 1.6m F Microphone & Earphone Cable Non-Shielded, 1.6m G Keyboard Cable Shielded, 1.8m H Mouse Cable Shielded, 1.8m I Power line Cable Non-Shielded, 1m J Recorder Cable Non-Shielded, 1m K USB Cable Shielded, 1.5m L USB Cable Shielded, 1.5m M RS-232 Cable Shielded, 1.5m

Page 11: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 9 of 53 V0.1-Draft

1.5. EUT Exercise Software

1 Setup the EUT and simulators as shown on 1.4. 2 Turn on the power of all equipment. 3 Personal Computer reads data from disk. 4 Personal Computer sends“H”pattern to printer, the printer will print“H”pattern on

paper. 5 Personal Computer reads and writes data into and from modem. 6 Personal Computer will read data from floppy disk and then writes the data into floppy

disk , same operation for hard disk. 7 Repeat the above procedure (4) to (6).

Page 12: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 10 of 53 V0.1-Draft

2. Technical Test

2.1. Summary of Test Result

No deviations from the test standards Deviations from the test standards as below description:

Emission

Performed Item Normative References Test

Performed Deviation

Conducted Emission FCC CFR Title 47 Part 15 Subpart B: 2007

Class AANSI C63.4: 2003

Yes No

Radiated Emission FCC CFR Title 47 Part 15 Subpart B: 2007

Class AANSI C63.4: 2003

Yes No

Page 13: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 11 of 53 V0.1-Draft

2.2. List of Test Equipment Conducted Emission / SR1 Instrument Manufacturer Type No. Serial No Cal. Date EMI Test Receiver R&S ESCS 30 836858/022 2008/02/12 LISN R&S ENV4200 833209/007 2007/07/13 LISN R&S ESH3-Z5 836679/020 2008/01/26 Pulse Limiter R&S ESH3-Z2 357.88.10.52 2007/09/04 Radiated Emission / Site5 Instrument Manufacturer Type No. Serial No Cal. Date Bilog Antenna Schaffner Chase CBL6112B 2920 2007/09/15 Broadband Horn Antenna Schwarzbeck BBHA9170 208 2007/07/25 EMI Test Receiver R&S ESCS 30 100369 2007/08/15 Horn Antenna Schwarzbeck BBHA9120D 305 2007/08/10 Pre-Amplifier QTK N/A N/A 2008/05/01 Spectrum Analyzer Advantest R3162 100803463 2008/01/03

Page 14: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 12 of 53 V0.1-Draft

2.3. Measurement Uncertainty Conducted Emission

The measurement uncertainty is evaluated as ± 2.26 dB.

Radiated Emission The measurement uncertainty is evaluated as ± 3.19 dB.

Page 15: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 13 of 53 V0.1-Draft

2.4. Test Environment

Performed Item Items Required Actual

Temperature (°C) 15-35 25

Conducted Emission Humidity (%RH) 25-75 50

Barometric pressure (mbar) 860-1060 950-1000

Temperature (°C) 15-35 25

Radiated Emission Humidity (%RH) 25-75 50

Barometric pressure (mbar) 860-1060 950-1000

Page 16: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 14 of 53 V0.1-Draft

3. Conducted Emission

3.1. Test Specification According to Standard : FCC Part 15 Subpart B, ANSI C63.4

3.2. Test Setup

3.3. Limit

Limits

Frequency (MHz)

QP (dBuV)

AV (dBuV)

0.15 - 0.50 79 66

0.50-5.0 73 60

5.0 - 30 73 60

Remarks: In the above table, the tighter limit applies at the band edges.

Page 17: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 15 of 53 V0.1-Draft

3.4. Test Procedure The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.) Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed on conducted measurement.

Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9kHz.

Page 18: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 16 of 53 V0.1-Draft

3.5. Test Result Site : SR-1 Time : 2008/06/17 - 13:10

Limit : CISPR_A_00M_QP Margin : 10

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (Keyboard)

Page 19: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 17 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:11

Limit : CISPR_A_00M_QP Margin : 0

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (Keyboard)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.349 0.300 44.400 44.700 -34.300 79.000 QUASIPEAK

2 0.701 0.310 37.620 37.930 -35.070 73.000 QUASIPEAK

3 1.400 0.330 34.430 34.760 -38.240 73.000 QUASIPEAK

4 2.451 0.360 31.500 31.860 -41.140 73.000 QUASIPEAK

5 7.338 0.510 32.670 33.180 -39.820 73.000 QUASIPEAK

6 14.748 0.990 26.440 27.430 -45.570 73.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 20: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 18 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:11

Limit : CISPR_A_00M_AV Margin : 0

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (Keyboard)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.349 0.300 43.180 43.480 -22.520 66.000 AVERAGE

2 0.701 0.310 35.980 36.290 -23.710 60.000 AVERAGE

3 1.400 0.330 32.250 32.580 -27.420 60.000 AVERAGE

4 2.451 0.360 26.090 26.450 -33.550 60.000 AVERAGE

5 7.338 0.510 25.470 25.980 -34.020 60.000 AVERAGE

6 14.748 0.990 26.420 27.410 -32.590 60.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 21: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 19 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:11

Limit : CISPR_A_00M_QP Margin : 10

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (Keyboard)

Page 22: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 20 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:11

Limit : CISPR_A_00M_QP Margin : 0

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (Keyboard)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.349 0.307 43.930 44.237 -34.763 79.000 QUASIPEAK

2 0.697 0.310 37.500 37.810 -35.190 73.000 QUASIPEAK

3 1.045 0.320 34.730 35.050 -37.950 73.000 QUASIPEAK

4 1.748 0.340 30.680 31.020 -41.980 73.000 QUASIPEAK

5 7.330 0.455 33.860 34.315 -38.685 73.000 QUASIPEAK

6 14.744 0.890 26.980 27.870 -45.130 73.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 23: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 21 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:11

Limit : CISPR_A_00M_AV Margin : 0

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (Keyboard)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.349 0.307 42.450 42.757 -23.243 66.000 AVERAGE

2 0.697 0.310 35.800 36.110 -23.890 60.000 AVERAGE

3 1.045 0.320 31.600 31.920 -28.080 60.000 AVERAGE

4 1.748 0.340 26.430 26.770 -33.230 60.000 AVERAGE

5 7.330 0.455 26.790 27.245 -32.755 60.000 AVERAGE

6 14.744 0.890 26.690 27.580 -32.420 60.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 24: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 22 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:19

Limit : CISPR_A_00M_QP Margin : 10

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (System Small)

Page 25: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 23 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:19

Limit : CISPR_A_00M_QP Margin : 0

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (System Small)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.195 0.682 49.470 50.152 -28.848 79.000 QUASIPEAK

2 0.377 0.300 44.510 44.810 -34.190 79.000 QUASIPEAK

3 0.826 0.310 36.170 36.480 -36.520 73.000 QUASIPEAK

4 1.970 0.340 31.780 32.120 -40.880 73.000 QUASIPEAK

5 11.091 0.640 39.530 40.170 -32.830 73.000 QUASIPEAK

6 15.705 1.010 40.860 41.870 -31.130 73.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 26: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 24 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:19

Limit : CISPR_A_00M_AV Margin : 0

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (System Small)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 0.195 0.682 38.590 39.272 -26.728 66.000 AVERAGE

2 * 0.377 0.300 43.210 43.510 -22.490 66.000 AVERAGE

3 0.826 0.310 33.450 33.760 -26.240 60.000 AVERAGE

4 1.970 0.340 23.210 23.550 -36.450 60.000 AVERAGE

5 11.091 0.640 32.210 32.850 -27.150 60.000 AVERAGE

6 15.705 1.010 23.220 24.230 -35.770 60.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 27: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 25 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:19

Limit : CISPR_A_00M_QP Margin : 10

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (System Small)

Page 28: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 26 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:19

Limit : CISPR_A_00M_QP Margin : 0

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (System Small)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.189 0.300 55.170 55.470 -23.530 79.000 QUASIPEAK

2 0.318 0.300 44.890 45.190 -33.810 79.000 QUASIPEAK

3 0.505 0.310 37.610 37.920 -35.080 73.000 QUASIPEAK

4 1.009 0.320 33.650 33.970 -39.030 73.000 QUASIPEAK

5 12.748 0.755 38.860 39.615 -33.385 73.000 QUASIPEAK

6 15.478 0.900 39.910 40.810 -32.190 73.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 29: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 27 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:19

Limit : CISPR_A_00M_AV Margin : 0

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (System Small)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.189 0.300 44.990 45.290 -20.710 66.000 AVERAGE

2 0.318 0.300 39.320 39.620 -26.380 66.000 AVERAGE

3 * 0.505 0.310 36.990 37.300 -22.700 60.000 AVERAGE

4 1.009 0.320 29.380 29.700 -30.300 60.000 AVERAGE

5 12.748 0.755 34.550 35.305 -24.695 60.000 AVERAGE

6 15.478 0.900 28.640 29.540 -30.460 60.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 30: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 28 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:22

Limit : CISPR_A_00M_QP Margin : 10

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (System BIG)

Page 31: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 29 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:22

Limit : CISPR_A_00M_QP Margin : 0

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (System BIG)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.177 0.749 57.930 58.679 -20.321 79.000 QUASIPEAK

2 0.236 0.395 42.150 42.545 -36.455 79.000 QUASIPEAK

3 0.351 0.300 31.240 31.540 -47.460 79.000 QUASIPEAK

4 1.978 0.340 32.950 33.290 -39.710 73.000 QUASIPEAK

5 6.545 0.480 35.580 36.060 -36.940 73.000 QUASIPEAK

6 27.033 1.200 40.650 41.850 -31.150 73.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 32: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 30 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:22

Limit : CISPR_A_00M_AV Margin : 0

EUT : GV-Access Control System Probe : LISN-L(023) - Line1

Power : AC 120V/60Hz Note : Mode 1 (System BIG)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.177 0.749 47.760 48.509 -17.491 66.000 AVERAGE

2 0.236 0.395 32.100 32.495 -33.505 66.000 AVERAGE

3 0.351 0.300 24.410 24.710 -41.290 66.000 AVERAGE

4 1.978 0.340 25.220 25.560 -34.440 60.000 AVERAGE

5 6.545 0.480 26.330 26.810 -33.190 60.000 AVERAGE

6 27.033 1.200 35.390 36.590 -23.410 60.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 33: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 31 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:22

Limit : CISPR_A_00M_QP Margin : 10

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (System BIG)

Page 34: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 32 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:22

Limit : CISPR_A_00M_QP Margin : 0

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (System BIG)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.177 0.300 58.070 58.370 -20.630 79.000 QUASIPEAK

2 0.357 0.309 40.120 40.429 -38.571 79.000 QUASIPEAK

3 0.533 0.310 30.670 30.980 -42.020 73.000 QUASIPEAK

4 2.283 0.355 25.640 25.995 -47.005 73.000 QUASIPEAK

5 6.275 0.440 36.520 36.960 -36.040 73.000 QUASIPEAK

6 27.033 1.060 40.690 41.750 -31.250 73.000 QUASIPEAK

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 35: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 33 of 53 V0.1-Draft

Site : SR-1 Time : 2008/06/17 - 13:22

Limit : CISPR_A_00M_AV Margin : 0

EUT : GV-Access Control System Probe : LISN-N(023) - Line2

Power : AC 120V/60Hz Note : Mode 1 (System BIG)

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV)

Margin

(dB)

Limit

(dBuV)

Detector Type

1 * 0.177 0.300 47.760 48.060 -17.940 66.000 AVERAGE

2 0.357 0.309 33.230 33.539 -32.461 66.000 AVERAGE

3 0.533 0.310 27.470 27.780 -32.220 60.000 AVERAGE

4 2.283 0.355 18.630 18.985 -41.015 60.000 AVERAGE

5 6.275 0.440 25.960 26.400 -33.600 60.000 AVERAGE

6 27.033 1.060 35.340 36.400 -23.600 60.000 AVERAGE

Note: 1. All Reading Levels are Quasi-Peak and average value. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 36: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 34 of 53 V0.1-Draft

3.6. Test Photograph Test Mode : Mode 1: Normal Operation (Keyboard) Description : Front View of Conducted Test

Test Mode : Mode 1: Normal Operation (Keyboard) Description : Back View of Conducted Test

Page 37: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 35 of 53 V0.1-Draft

Test Mode : Mode 1: Normal Operation (System Small) Description : Front View of Conducted Test

Test Mode : Mode 1: Normal Operation (System Small) Description : Back View of Conducted Test

Page 38: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 36 of 53 V0.1-Draft

Test Mode : Mode 1: Normal Operation (System BIG) Description : Front View of Conducted Test

Test Mode : Mode 1: Normal Operation (System BIG) Description : Back View of Conducted Test

Page 39: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 37 of 53 V0.1-Draft

4. Radiated Emission

4.1. Test Specification

According to EMC Standard : FCC Part 15 Subpart B, ANSI C63.4

4.2. Test Setup

Under 1GHz Test Setup:

Above 1GHz Test Setup:

Page 40: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 38 of 53 V0.1-Draft

4.3. Limit Under 1GHz test shall not exceed the following value:

Limits Frequency

(MHz) Distance (m) dBuV/m

30 – 230 10 40

230 – 1000 10 47

Remark: 1. The tighter limit shall apply at the edge between two frequency bands. 2. Distance refers to the distance in meters between the measuring instrument antenna and

the closed point of any part of the device or system.

Above 1GHz test shall not exceed the following value:

FCC Part 15 Subpart B Paragraph 15.109 Limits (dBuV/m)

Frequency (MHz)

Distance (m) dBuV/m

30-88 10 39

88-216 10 43.5

216-960 10 46.4

Above 960 10 49.5

Remark:

1. The tighter limit shall apply at the edge between two frequency bands.

2. Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the device or system.

3. RF Voltage (dBuV/m) = 20 log RF Voltage (uV/m)

Page 41: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 39 of 53 V0.1-Draft

4.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.

The turn table can rotate 360 degrees to determine the position of the maximum emission level and the antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level.

Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated on radiated measurement.

For an unintentional radiator, including a digital device, the spectrum shall be investigated from the lowest radio frequency signal generated or used in the device, without going below the lowest frequency for which a radiated emission limit is specified, up to the frequency shown in the folowing table:

Highest frequency generated or used in the device or on which the

device operates or tunes (MHz)

Upper frequency of measurement range (MHz)

Below 1.705 30

1.705 – 108 1000

108 – 500 2000

500 – 1000 5000

Above 1000 5th harmonic of the highest

frequency or 40 GHz, whichever is lower

On any frequency or frequencies below or equal to 1000 MHz, the radiated limits shown are based on measuring equipment employing a quasi-peak detector function and above 1000 MHz, the radiated limits shown are based measuring equipment employing an average detector function. When average radiated emission measurement are included emission measurement Above 1000 MHz, there also is a limit on the radio frequency emissions, as measured using instrumentation with a peak detector function, corresponding to 20 dB above the maximum permitted average limit. For class A, the measurement distance between the EUT and antenna is 10 meters for under 1GHz and above 1GHz. For class B, the measurement distance between the EUT and antenna is 10 meters for under 1GHz and 3 meters for above 1GHz.

The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS 30) is 120 kHz and above 1GHz is 1MHz.

Page 42: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 40 of 53 V0.1-Draft

4.5. Test Result Site : OATS-5 Time : 2008/06/12 - 17:26

Limit : CISPR_A_10M_QP Margin : 6

EUT : GV-Access Control System Probe : 2007_Site5(2921)_10M - HORIZONTAL

Power : AC 120V/60Hz Note : Mode 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 58.740 7.083 26.390 33.472 -6.528 40.000 QUASIPEAK

2 115.270 13.750 20.160 33.910 -6.090 40.000 QUASIPEAK

3 192.005 11.603 18.660 30.263 -9.737 40.000 QUASIPEAK

4 * 375.035 19.801 26.170 45.971 -1.029 47.000 QUASIPEAK

5 500.046 23.074 14.620 37.694 -9.306 47.000 QUASIPEAK

6 625.059 25.156 12.660 37.815 -9.185 47.000 QUASIPEAK

7 720.020 26.913 8.280 35.193 -11.807 47.000 QUASIPEAK

8 1000.000 29.878 5.710 35.588 -11.412 47.000 QUASIPEAK

Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 43: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 41 of 53 V0.1-Draft

Site : OATS-5 Time : 2008/06/12 - 17:11

Limit : CISPR_A_10M_QP Margin : 6

EUT : GV-Access Control System Probe : 2007_Site5(2921)_10M - VERTICAL

Power : AC 120V/60Hz Note : Mode 1

Frequency

(MHz)

Correct Factor

(dB)

Reading Level

(dBuV)

Measure Level

(dBuV/m)

Margin

(dB)

Limit

(dBuV/m)

Detector Type

1 59.460 6.973 23.730 30.703 -9.297 40.000 QUASIPEAK

2 109.414 13.550 18.170 31.720 -8.280 40.000 QUASIPEAK

3 192.008 11.603 20.030 31.633 -8.367 40.000 QUASIPEAK

4 * 375.035 19.801 23.120 42.921 -4.079 47.000 QUASIPEAK

5 500.047 23.074 12.960 36.034 -10.966 47.000 QUASIPEAK

6 720.023 26.913 4.310 31.223 -15.777 47.000 QUASIPEAK

7 1000.000 29.878 5.610 35.488 -11.512 47.000 QUASIPEAK

Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. " * ", means this data is the worst emission level. 3. Measurement Level = Reading Level + Correct Factor

Page 44: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 42 of 53 V0.1-Draft

4.6. Test Photograph Test Mode : Mode 1: Normal Operation Description : Front View of Radiated Test

Test Mode : Mode 1: Normal Operation Description : Back View of Radiated Test

Page 45: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 43 of 53 V0.1-Draft

5. Attachment EUT Photograph

(1) EUT Photo

(2) EUT Photo

Page 46: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 44 of 53 V0.1-Draft

(3) EUT Photo

(4) EUT Photo

Page 47: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 45 of 53 V0.1-Draft

(5) EUT Photo

(6) EUT Photo

Page 48: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 46 of 53 V0.1-Draft

(7) EUT Photo

(8) EUT Photo

Page 49: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 47 of 53 V0.1-Draft

(9) EUT Photo

(10) EUT Photo

Page 50: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 48 of 53 V0.1-Draft

(11) EUT Photo

(12) EUT Photo

Page 51: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 49 of 53 V0.1-Draft

(13) EUT Photo

(14) EUT Photo

Page 52: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 50 of 53 V0.1-Draft

(15) EUT Photo

(16) EUT Photo

Page 53: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 51 of 53 V0.1-Draft

(17) EUT Photo

(18) EUT Photo

Page 54: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 52 of 53 V0.1-Draft

(19) EUT Photo

(20) EUT Photo

Page 55: 085285R-ITUSP02V01-rpt-. ..-GV-Access Control System GV-api.ivv-aut.com/adp/21 - CCTV ANALÓGICO/2108... · Company Name : GeoVision Inc. This product, which has been issued the test

Report No: 085285R-ITUSP02V01

Page: 53 of 53 V0.1-Draft

(21) EUT Photo